source: trunk/MagicSoft/TDAS-Extractor/Criteria.tex@ 5954

Last change on this file since 5954 was 5783, checked in by gaug, 20 years ago
*** empty log message ***
File size: 2.8 KB
Line 
1\section{Criteria for the Optimal Signal Extraction}
2
3\subsection{Resolution (amplitude and time)}
4\ldots {\textit{In this section, the jitter to exactly identical input pulses is measured, for times, amplitudes,
5high-gain and low-gain pulses }}
6\begin{itemize}
7\item Jitter to pulpo pulses \ldots Hendrik
8\item Comparing MC signal with and w/o noise of different intensity \ldots Nuria
9\item Jitter to pedestals (of different intensity) \ldots Hendrik
10\item Comparing the low-gain to high-gain ratio for different intensities \ldots Markus
11\item Derive the time jitter to calibration pulses \ldots Maxim ???
12\end{itemize}
13
14\subsection{Bias}
15\ldots {\textit In this section, the bias of the extractor for low and high intensities is defined and measured }
16\begin{itemize}
17\item Bias to pedestals (of different intensity) \ldots Hendrik
18\item Comparing MC signal with and w/o noise of different intensity \ldots Nuria
19\end{itemize}
20
21\subsection{Signal to Noise}
22\ldots {\textit In this section, the signal to noise of an extractor is determined, for times and amplitudes
23\newline \ldots Maxim ???, Thomas ???}
24
25\subsection{Stability}
26\ldots {\textit In this section, the stability of an extractor to slightly varying pulse shapes is examined. }
27\begin{itemize}
28\item Stability w.r.t. different weights files \ldots Hendrik
29\item Outliers in time and amplitude extractions \ldots ???
30\item Stability of conversion factors from the calibration \ldots Markus
31\item Stability w.r.t. the calibration secondary pulses \ldots Hendrik ???
32\end{itemize}
33
34\subsection{Linearity}
35\ldots {\textit In this section, the Nuria plots are examined \newline \ldots Nuria}
36
37\subsection{Treatment of Calibration Pulses}
38\ldots {\textit In this section, the question of the different pulse shapes between calibration pulses, its
39secondary pulses, possible secondary pulses from hadronic showers and the typical Cherenkov
40pulses are extracted by the different extractors and typical dependencies examined, like the
41Razmik plot, the number of photo-electrons with number of slices, comparisons between different colours, etc.
42\newline \ldots Hendrik??? , Markus??? + ????}
43
44\subsection{Low Gain Extraction}
45\ldots {\textit In this section, the stability of the low-gain extraction w.r.t. the high-gain extraction is
46examined. Useful plots are still to be defined.
47\newline \ldots Arnau ????}
48
49\subsection{Applicability for Different Sampling Speeds / No Pulse Shaping.}
50\ldots {\textit In this section, some comments of Hendrik will be made}
51
52\subsection{CPU Requirements}
53\ldots {\textit In this section, the needed CPU time is measured for each extractor independently }
54\newline \ldots {\textit ALL (after all)}
55
56
57%%% Local Variables:
58%%% mode: latex
59%%% TeX-master: "MAGIC_signal_reco"
60%%% TeX-master: "MAGIC_signal_reco"
61%%% End:
Note: See TracBrowser for help on using the repository browser.