| 1 | \section{Pedestal Extraction \label{sec:pedestals}}
|
|---|
| 2 |
|
|---|
| 3 | \subsection{Pedestal RMS}
|
|---|
| 4 |
|
|---|
| 5 | The background $BG$ (Pedestal)
|
|---|
| 6 | can be completely described by the noise-autocorrelation matrix $\boldsymbol{B}$
|
|---|
| 7 | (eq.~\ref{eq:autocorr}),
|
|---|
| 8 | where the square root of the diagonal elements give what is usually denoted as the ``pedestal RMS''.
|
|---|
| 9 | \par
|
|---|
| 10 |
|
|---|
| 11 | By definition, $\boldsymbol{B}$ and thus the ``pedestal RMS''
|
|---|
| 12 | is independent of the signal extractor.
|
|---|
| 13 |
|
|---|
| 14 | \subsection{Pedestal Fluctuations as Contribution to the Signal Fluctuations \label{sec:ffactor}}
|
|---|
| 15 |
|
|---|
| 16 | A photo-multiplier signal yields, to a very good approximation, the
|
|---|
| 17 | following relation:
|
|---|
| 18 |
|
|---|
| 19 | \begin{equation}
|
|---|
| 20 | \frac{Var[Q]}{<Q>^2} = \frac{1}{<n_{\mathrm{phe}}>} * F^2
|
|---|
| 21 | \end{equation}
|
|---|
| 22 |
|
|---|
| 23 | Here, $Q$ is the signal due to a number $n_{\mathrm{phe}}$ of signal photo-electrons
|
|---|
| 24 | (equiv. to the signal $S$) after subtraction of the pedestal. $Var[Q]$ is the fluctuation of the true signal $Q$
|
|---|
| 25 | due to the Poisson fluctuations of the number of photo-electrons. Because of:
|
|---|
| 26 |
|
|---|
| 27 | \begin{eqnarray}
|
|---|
| 28 | \widehat{Q} &=& Q + X \\
|
|---|
| 29 | Var[\widehat{Q}] &=& Var[Q] + Var[X] \\
|
|---|
| 30 | Var[Q] &=& Var[\widehat{Q}] - Var[X]
|
|---|
| 31 | \end{eqnarray}
|
|---|
| 32 |
|
|---|
| 33 | Here, $Var[X]$ is the fluctuation due to the signal extraction, mainly as a result of the background fluctuations and
|
|---|
| 34 | the numerical precision of the extraction algorithm.
|
|---|
| 35 | \par
|
|---|
| 36 | Only in the case that the intrinsic extractor resolution $R$ at fixed background $BG$ does not depend on the signal
|
|---|
| 37 | intensity\footnote{Theoretically, this is the case for the digital filter, eq.~\ref{eq:of_noise}.},
|
|---|
| 38 | $Var[Q]$ can be obtained from:
|
|---|
| 39 |
|
|---|
| 40 | \begin{eqnarray}
|
|---|
| 41 | Var[Q] &\approx& Var[\widehat{Q}] - Var[\widehat{Q}]\,\vline_{\,Q=0}
|
|---|
| 42 | \label{eq:rmssubtraction}
|
|---|
| 43 | \end{eqnarray}
|
|---|
| 44 |
|
|---|
| 45 | %\footnote{%
|
|---|
| 46 | %A way to check whether the right RMS has been subtracted is to make the
|
|---|
| 47 | %``Razmick''-plot
|
|---|
| 48 | %
|
|---|
| 49 | %\begin{equation}
|
|---|
| 50 | % \frac{Var[\widehat{Q}]}{<\widehat{Q}>^2} \quad \textit{vs.} \quad \frac{1}{<\widehat{Q}>}
|
|---|
| 51 | %\end{equation}
|
|---|
| 52 | %
|
|---|
| 53 | %This should give a straight line passing through the origin. The slope of
|
|---|
| 54 | %the line is equal to
|
|---|
| 55 | %
|
|---|
| 56 | %\begin{equation}
|
|---|
| 57 | % c * F^2
|
|---|
| 58 | %\end{equation}
|
|---|
| 59 | %
|
|---|
| 60 | %where $c$ is the photon/ADC conversion factor $<Q>/<m_{pe}>$.}
|
|---|
| 61 |
|
|---|
| 62 | One can determine $R$ by applying the signal extractor with a {\textit{\bf fixed window}} to pedestal events, where the
|
|---|
| 63 | bias vanishes and measure $Var(\widehat{Q})\,\vline_{\,Q=0}$.
|
|---|
| 64 |
|
|---|
| 65 | \subsection{Methods to Retrieve Bias and Mean-Squared Error}
|
|---|
| 66 |
|
|---|
| 67 | In general, the extracted signal variance $R$ is different from the pedestal RMS.
|
|---|
| 68 | It can be obtained by applying the signal extractor to pedestal events yielding the bias and
|
|---|
| 69 | the resolution $R$.
|
|---|
| 70 | \par
|
|---|
| 71 | In the case of the digital filter, $R$ is expected to be independent of the
|
|---|
| 72 | signal amplitude $S$ and dependent only on the background $BG$ (eq.~\ref{eq:of_noise}).
|
|---|
| 73 | %It can then be obtained from the calculation of the variance $Var[\widehat{Q}]$
|
|---|
| 74 | %by applying the extractor with a fixed window to pure background events (``pedestal events'').
|
|---|
| 75 | \par
|
|---|
| 76 |
|
|---|
| 77 | In order to calculate the statistical parameters, we proceed in the following ways:
|
|---|
| 78 | \begin{enumerate}
|
|---|
| 79 | \item Determine $R$ by applying the signal extractor to a fixed window
|
|---|
| 80 | of pedestal events. The background fluctuations can be simulated with different
|
|---|
| 81 | levels of night sky background and the continuous light source, but no signal size
|
|---|
| 82 | dependence can be retrieved by this method.
|
|---|
| 83 | \item Determine $B$ and $MSE$ from MC events with added noise.
|
|---|
| 84 | % Assuming that $MSE$ and $B$ are negligible for the events without noise, one can
|
|---|
| 85 | With this method, one can get a dependence of both values on the size of the signal,
|
|---|
| 86 | although the MC might contain systematic differences with respect to the real data.
|
|---|
| 87 | \item Determine $MSE$ from the error retrieved from the fit results of $\widehat{S}$, which is possible for the
|
|---|
| 88 | fit and the digital filter (eq.~\ref{eq:of_noise}).
|
|---|
| 89 | In principle, all dependencies can be retrieved with this method, although some systematic errors are not taken into account
|
|---|
| 90 | with this method: Deviations of the real pulse from the fitted one, errors in the noise auto-correlation matrix and numerical
|
|---|
| 91 | precision issues. All these systematic effects add an additional contribution to the true resolution proportional to the signal strength.
|
|---|
| 92 | \end{enumerate}
|
|---|
| 93 |
|
|---|
| 94 |
|
|---|
| 95 | \begin{figure}[htp]
|
|---|
| 96 | \centering
|
|---|
| 97 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeSpline_Amplitude_Amplitude_Range_01_09_01_10_Run_38993_RelMean.eps}
|
|---|
| 98 | \vspace{\floatsep}
|
|---|
| 99 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeSpline_Amplitude_Amplitude_Range_01_09_01_10_Run_38995_RelMean.eps}
|
|---|
| 100 | \vspace{\floatsep}
|
|---|
| 101 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeSpline_Amplitude_Amplitude_Range_01_09_01_10_Run_38996_RelMean.eps}
|
|---|
| 102 | \caption{MExtractTimeAndChargeSpline with amplitude extraction:
|
|---|
| 103 | Difference in mean pedestal (per FADC slice) between extraction algorithm
|
|---|
| 104 | applied on a fixed window of 1 FADC slice (``extractor random'') and a simple addition of
|
|---|
| 105 | 2 fixed FADC slices (``fundamental''). On the left, a run with closed camera has been taken, in the center
|
|---|
| 106 | an opened camera observing an extra-galactic star field and on the right, an open camera being
|
|---|
| 107 | illuminated by the continuous light of the calibration (level: 100). Every entry corresponds to one
|
|---|
| 108 | pixel.}
|
|---|
| 109 | \label{fig:amp:relmean}
|
|---|
| 110 | \end{figure}
|
|---|
| 111 |
|
|---|
| 112 | \begin{figure}[htp]
|
|---|
| 113 | \centering
|
|---|
| 114 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeSpline_Rise-and-Fall-Time_0.5_1.5_Range_01_10_02_12_Run_38993_RelMean.eps}
|
|---|
| 115 | \vspace{\floatsep}
|
|---|
| 116 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeSpline_Rise-and-Fall-Time_0.5_1.5_Range_01_10_02_12_Run_38995_RelMean.eps}
|
|---|
| 117 | \vspace{\floatsep}
|
|---|
| 118 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeSpline_Rise-and-Fall-Time_0.5_1.5_Range_01_10_02_12_Run_38996_RelMean.eps}
|
|---|
| 119 | \caption{MExtractTimeAndChargeSpline with integral over 2 slices:
|
|---|
| 120 | Difference in mean pedestal (per FADC slice) between extraction algorithm
|
|---|
| 121 | applied on a fixed window of 2 FADC slices (``extractor random'') and a simple addition of
|
|---|
| 122 | 2 FADC fixed slices (``fundamental''). On the left, a run with closed camera has been taken, in the center
|
|---|
| 123 | an opened camera observing an extra-galactic star field and on the right, an open camera being
|
|---|
| 124 | illuminated by the continuous light of the calibration (level: 100). Every entry corresponds to one
|
|---|
| 125 | pixel.}
|
|---|
| 126 | \label{fig:int:relmean}
|
|---|
| 127 | \end{figure}
|
|---|
| 128 |
|
|---|
| 129 | \begin{figure}[htp]
|
|---|
| 130 | \centering
|
|---|
| 131 | \vspace{\floatsep}
|
|---|
| 132 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeDigitalFilter_Weights_cosmics_weights.dat_Range_01_14_02_14_Run_38993_RelMean.eps}
|
|---|
| 133 | \vspace{\floatsep}
|
|---|
| 134 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeDigitalFilter_Weights_cosmics_weights.dat_Range_01_14_02_14_Run_38995_RelMean.eps}
|
|---|
| 135 | \vspace{\floatsep}
|
|---|
| 136 | \includegraphics[width=0.3\linewidth]{MExtractTimeAndChargeDigitalFilter_Weights_cosmics_weights.dat_Range_01_14_02_14_Run_38996_RelMean.eps}
|
|---|
| 137 | \caption{MExtractTimeAndChargeDigitalFilter:
|
|---|
| 138 | Difference in mean pedestal (per FADC slice) between extraction algorithm
|
|---|
| 139 | applied on a fixed window of 6 FADC slices and time-randomized weights (``extractor random'')
|
|---|
| 140 | and a simple addition of
|
|---|
| 141 | 6 FADC fixed slices (``fundamental''). On the left, a run with closed camera has been taken, in the center
|
|---|
| 142 | an opened camera observing an extra-galactic star field and on the right, an open camera being
|
|---|
| 143 | illuminated by the continuous light of the calibration (level: 100). Every entry corresponds to one
|
|---|
| 144 | pixel.}
|
|---|
| 145 | \label{fig:df:relmean}
|
|---|
| 146 | \end{figure}
|
|---|
| 147 |
|
|---|
| 148 | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|---|
| 149 |
|
|---|
| 150 | \subsubsection{ \label{sec:ped:fixedwindow} Application of the Signal Extractor to a Fixed Window
|
|---|
| 151 | of Pedestal Events}
|
|---|
| 152 |
|
|---|
| 153 | By applying the signal extractor with a fixed window to pedestal events, we
|
|---|
| 154 | determine the parameter $R$ for the case of no signal ($Q = 0$)\footnote{%
|
|---|
| 155 | In the case of
|
|---|
| 156 | extractors using a fixed window (extractors nr. \#1 to \#22
|
|---|
| 157 | in section~\ref{sec:algorithms}), the results are the same by construction
|
|---|
| 158 | as calculating the RMS of the sum of a fixed number of FADC slice, traditionally
|
|---|
| 159 | named ``pedestal RMS'' in MARS.}.
|
|---|
| 160 | \par
|
|---|
| 161 | In MARS, this functionality is implemented with a function-call to: \\
|
|---|
| 162 |
|
|---|
| 163 | {\textit{\bf MJPedestal::SetExtractionWithExtractorRndm()}} including \\
|
|---|
| 164 | {\textit{\bf MExtractPedestal::SetRandomCalculation()}}\\
|
|---|
| 165 |
|
|---|
| 166 | Besides fixing the global extraction window, additionally the following steps are undertaken
|
|---|
| 167 | in order to assure an un-biased resolution.
|
|---|
| 168 |
|
|---|
| 169 | \begin{description}
|
|---|
| 170 | \item[\textit{MExtractTimeAndChargeSpline}:\xspace] The spline
|
|---|
| 171 | maximum position -- which determines the exact extraction window -- is placed
|
|---|
| 172 | at a random place within the digitizing binning resolution of one central FADC slice.
|
|---|
| 173 | \item[\textit{MExtractTimeAndChargeDigitalFilter}:\xspace] The second step timing
|
|---|
| 174 | offset $\tau$ (eq.~\ref{eq:offsettau}) is chosen randomly for each event.
|
|---|
| 175 | \end{description}
|
|---|
| 176 |
|
|---|
| 177 | \par
|
|---|
| 178 |
|
|---|
| 179 | The following figures~\ref{fig:amp:relmean} through~\ref{fig:df:relrms} show results
|
|---|
| 180 | obtained with the second method for three background intensities:
|
|---|
| 181 |
|
|---|
| 182 | \begin{enumerate}
|
|---|
| 183 | \item Closed camera and no (Poissonian) fluctuation due to photons from the night sky background
|
|---|
| 184 | \item The camera pointing to an extra-galactic region with stars in the field of view
|
|---|
| 185 | \item The camera illuminated by a continuous light source of intensity 100.
|
|---|
| 186 | \end{enumerate}
|
|---|
| 187 |
|
|---|
| 188 | Figures~\ref{fig:amp:relmean} through~\ref{fig:df:relmean}
|
|---|
| 189 | show the calculated biases obtained with this method for all pixels in the camera
|
|---|
| 190 | and for the different levels of (night-sky) background applied to 1000 pedestal events.
|
|---|
| 191 | One can see that the bias vanishes to an accuracy of better than 2\% of a photo-electron
|
|---|
| 192 | makefor the extractors which are used in this TDAS.
|
|---|
| 193 |
|
|---|
| 194 | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%1
|
|---|
| 195 |
|
|---|
| 196 | \begin{figure}[htp]
|
|---|
| 197 | \centering
|
|---|
| 198 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeSpline_Amplitude_Amplitude_Range_01_09_01_10_Run_38993_RMSDiff.eps}
|
|---|
| 199 | \vspace{\floatsep}
|
|---|
| 200 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeSpline_Amplitude_Amplitude_Range_01_09_01_10_Run_38995_RMSDiff.eps}
|
|---|
| 201 | \vspace{\floatsep}
|
|---|
| 202 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeSpline_Amplitude_Amplitude_Range_01_09_01_10_Run_38996_RMSDiff.eps}
|
|---|
| 203 | \caption{MExtractTimeAndChargeSpline with amplitude:
|
|---|
| 204 | Difference in RMS (per FADC slice) between extraction algorithm
|
|---|
| 205 | applied on a fixed window and the corresponding pedestal RMS.
|
|---|
| 206 | Closed camera (left), open camera observing extra-galactic star field (right) and
|
|---|
| 207 | camera being illuminated by the continuous light (bottom).
|
|---|
| 208 | Every entry corresponds to one pixel.}
|
|---|
| 209 | \label{fig:amp:relrms}
|
|---|
| 210 | \end{figure}
|
|---|
| 211 |
|
|---|
| 212 |
|
|---|
| 213 | \begin{figure}[htp]
|
|---|
| 214 | \centering
|
|---|
| 215 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeSpline_Rise-and-Fall-Time_0.5_1.5_Range_01_10_02_12_Run_38993_RMSDiff.eps}
|
|---|
| 216 | \vspace{\floatsep}
|
|---|
| 217 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeSpline_Rise-and-Fall-Time_0.5_1.5_Range_01_10_02_12_Run_38995_RMSDiff.eps}
|
|---|
| 218 | \vspace{\floatsep}
|
|---|
| 219 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeSpline_Rise-and-Fall-Time_0.5_1.5_Range_01_10_02_12_Run_38996_RMSDiff.eps}
|
|---|
| 220 | \caption{MExtractTimeAndChargeSpline with integral over 2 slices:
|
|---|
| 221 | Difference in RMS (per FADC slice) between extraction algorithm
|
|---|
| 222 | applied on a fixed window and the corresponding pedestal RMS.
|
|---|
| 223 | Closed camera (left), open camera observing extra-galactic star field (right) and
|
|---|
| 224 | camera being illuminated by the continuous light (bottom).
|
|---|
| 225 | Every entry corresponds to one
|
|---|
| 226 | pixel.}
|
|---|
| 227 | \label{fig:int:relrms}
|
|---|
| 228 | \end{figure}
|
|---|
| 229 |
|
|---|
| 230 |
|
|---|
| 231 | \begin{figure}[htp]
|
|---|
| 232 | \centering
|
|---|
| 233 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeDigitalFilter_Weights_cosmics_weights.dat_Range_01_14_02_14_Run_38993_RMSDiff.eps}
|
|---|
| 234 | \vspace{\floatsep}
|
|---|
| 235 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeDigitalFilter_Weights_cosmics_weights.dat_Range_01_14_02_14_Run_38995_RMSDiff.eps}
|
|---|
| 236 | \vspace{\floatsep}
|
|---|
| 237 | \includegraphics[width=0.47\linewidth]{MExtractTimeAndChargeDigitalFilter_Weights_cosmics_weights.dat_Range_01_14_02_14_Run_38996_RMSDiff.eps}
|
|---|
| 238 | \caption{MExtractTimeAndChargeDigitalFilter:
|
|---|
| 239 | Difference in RMS (per FADC slice) between extraction algorithm
|
|---|
| 240 | applied on a fixed window and the corresponding pedestal RMS.
|
|---|
| 241 | Closed camera (left), open camera observing extra-galactic star field (right) and
|
|---|
| 242 | camera being illuminated by the continuous light (bottom).
|
|---|
| 243 | Every entry corresponds to one pixel.}
|
|---|
| 244 | \label{fig:df:relrms}
|
|---|
| 245 | \end{figure}
|
|---|
| 246 |
|
|---|
| 247 |
|
|---|
| 248 |
|
|---|
| 249 | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|---|
| 250 |
|
|---|
| 251 | Figures~\ref{fig:amp:relrms} through~\ref{fig:df:relrms} show the
|
|---|
| 252 | differences in $R$ between the RMS of simply summing up the FADC slices over the extraction window
|
|---|
| 253 | (in MARS called: ``Fundamental Pedestal RMS'') and
|
|---|
| 254 | the one obtained by applying the extractor to the same extraction window
|
|---|
| 255 | (in MARS called: ``Pedestal RMS with Extractor Rndm''). One entry of each histogram corresponds to one
|
|---|
| 256 | pixel of the camera.
|
|---|
| 257 | The distributions have a negative mean in the case of the digital filter showing the
|
|---|
| 258 | ``filter'' capacity of that algorithm. It ``filters out'' between 0.12 photo-electrons night sky
|
|---|
| 259 | background for the extra-galactic star-field until 0.2 photo-electrons for the continuous light.
|
|---|
| 260 |
|
|---|
| 261 | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|---|
| 262 |
|
|---|
| 263 |
|
|---|
| 264 | \subsubsection{ \label{sec:ped:slidingwindow} Application of the Signal Extractor to a Sliding Window
|
|---|
| 265 | of Pedestal Events}
|
|---|
| 266 |
|
|---|
| 267 | By applying the signal extractor with a global extraction window to pedestal events, allowing
|
|---|
| 268 | it to ``slide'' and maximize the encountered signal, we
|
|---|
| 269 | determine the bias $B$ and the mean-squared error $MSE$ for the case of no signal ($S=0$).
|
|---|
| 270 | \par
|
|---|
| 271 | In MARS, this functionality is implemented with a function-call to: \\
|
|---|
| 272 |
|
|---|
| 273 | {\textit{\bf MJPedestal::SetExtractionWithExtractor()}} \\
|
|---|
| 274 |
|
|---|
| 275 | \par
|
|---|
| 276 | Table~\ref{tab:bias} shows the bias, the resolution and the mean-square error for all extractors using
|
|---|
| 277 | a sliding window. In this sample, every extractor had the freedom to move 5 slices,
|
|---|
| 278 | i.e. the global window size was fixed to five plus the extractor window size. This first line
|
|---|
| 279 | shows the resolution of the smallest existing robust fixed window algorithm in order to give the reference
|
|---|
| 280 | value of 2.5 and 3 photo-electrons RMS for an extra-galactic and a galactic star-field, respectively.
|
|---|
| 281 | \par
|
|---|
| 282 | One can see that the bias $B$ typically decreases
|
|---|
| 283 | with increasing window size, while the error $R$ increases with
|
|---|
| 284 | increasing window size, except for the digital filter. There is also a small difference between the obtained error
|
|---|
| 285 | on a fixed window extraction and the one obtained from a sliding window extraction in the case of the spline and digital
|
|---|
| 286 | filter algorithms.
|
|---|
| 287 | The mean-squared error has an optimum somewhere in between: In the case of the
|
|---|
| 288 | sliding window and the spline at the lowest window size, in the case of the digital filter
|
|---|
| 289 | at 4 slices. The global winners is extractor~\#29
|
|---|
| 290 | (digital filter with integration of 4 slices). All sliding window extractors -- except \#21 --
|
|---|
| 291 | have a smaller mean-square error than the resolution of the fixed window reference extractor (row\ 1,\#4). This means
|
|---|
| 292 | that the global error of the sliding window extractors is smaller than the one of the fixed window extractors
|
|---|
| 293 | with 8~FADC slices even if the first have a bias.
|
|---|
| 294 | \par
|
|---|
| 295 | The important information for the image cleaning is the number of photo-electrons above which the probability for obtaining
|
|---|
| 296 | a noise fluctuation is smaller than 0.3\% (3$\sigma$). We approximated that number with the formula:
|
|---|
| 297 |
|
|---|
| 298 | \begin{equation}
|
|---|
| 299 | N_{\mathrm{phe}}^{\mathrm{thres.}} \approx B + 3\cdot R
|
|---|
| 300 | \end{equation}
|
|---|
| 301 |
|
|---|
| 302 | Table~\ref{tab:bias} shows that most of the sliding window algorithms yield a smaller signal threshold than the fixed window ones,
|
|---|
| 303 | although the first have a bias. The lowest threshold of only 4.2~photo-electrons for the extra-galactic star-field and 5.0~photo-electrons
|
|---|
| 304 | for the galactic star-field is obtained by the digital filter fitting 4 FADC slices (extractor~\%29).
|
|---|
| 305 | This is almost a factor 2 lower than the fixed window results. Also the spline integrating 1 FADC slice (extractor~\%24) yields almost
|
|---|
| 306 | comparable results.
|
|---|
| 307 |
|
|---|
| 308 | \begin{landscape}
|
|---|
| 309 | %\rotatebox{90}{%
|
|---|
| 310 | \begin{table}[htp]
|
|---|
| 311 | \vspace{3cm}
|
|---|
| 312 | \scriptsize{%
|
|---|
| 313 | \centering
|
|---|
| 314 | \begin{tabular}{|c|c|c|c|c|c|c|c|c|c|c|c|c|c|c|c|}
|
|---|
| 315 | \hline
|
|---|
| 316 | \hline
|
|---|
| 317 | \multicolumn{16}{|c|}{Statistical Parameters for $S=0$ units in $N_{\mathrm{phe}}$} \\
|
|---|
| 318 | \hline
|
|---|
| 319 | \hline
|
|---|
| 320 | & & \multicolumn{4}{|c|}{Closed camera} & \multicolumn{5}{|c|}{Extra-galactic NSB} & \multicolumn{5}{|c|}{Galactic NSB} \\
|
|---|
| 321 | \hline
|
|---|
| 322 | \hline
|
|---|
| 323 | Nr. & Name & $R$ & $R$ & $B$ & $\sqrt{MSE}$ & $R$ &$R$ & $B$ & $\sqrt{MSE}$ & $B+3R$ & $R$ & $R$& $B$ & $\sqrt{MSE}$ & $B+3R$ \\
|
|---|
| 324 | & & (FW) & (SW)& (SW)& (SW) & (FW) &(SW) & (SW)& (SW) & (99.7\% prob.) & (FW)&(SW) & (SW)&(SW) & (99.7\% prob.) \\
|
|---|
| 325 | \hline
|
|---|
| 326 | \hline
|
|---|
| 327 | 4 & Fixed Win. 8 & 1.2 & -- & 0.0 & 1.2 & 2.5 & -- & 0.0 & 2.5 & 7.5 & 3.0 & -- & 0.0 & 3.0 & 9.0 \\
|
|---|
| 328 | \hline
|
|---|
| 329 | -- & Slid. Win. 1 & 0.4 & 0.4 & 0.4 & 0.6 & 1.2 & 1.2 & 1.3 & 1.8 & 4.9 & 1.4 & 1.4 & 1.5 & 2.0 & 5.7 \\
|
|---|
| 330 | 17 & Slid. Win. 2 & 0.5 & 0.5 & 0.4 & 0.6 & 1.4 & 1.4 & 1.2 & 1.8 & 5.4 & 1.6 & 1.6 & 1.5 & 2.2 & 6.1 \\
|
|---|
| 331 | 18 & Slid. Win. 4 & 0.8 & 0.8 & 0.5 & 0.9 & 1.9 & 1.9 & 1.2 & 2.2 & 6.9 & 2.2 & 2.3 & 1.6 & 2.8 & 7.5 \\
|
|---|
| 332 | 20 & Slid. Win. 6 & 1.0 & 1.0 & 0.4 & 1.1 & 2.2 & 2.2 & 1.1 & 2.5 & 7.7 & 2.6 & 2.7 & 1.4 & 3.0 & 9.5 \\
|
|---|
| 333 | 21 & Slid. Win. 8 & 1.2 & 1.3 & 0.4 & 1.4 & 2.5 & 2.5 & 1.0 & 2.7 & 8.5 & 3.0 & 3.2 & 1.4 & 3.5 & 10.0 \\
|
|---|
| 334 | \hline
|
|---|
| 335 | 23 & Spline Amp. & 0.4 & \textcolor{red}{\bf 0.4} & 0.4 & 0.6 & 1.1 & 1.2 & 1.3 & 1.8 & 4.9 & 1.3 & 1.4 & 1.6 & 2.1 & 5.8 \\
|
|---|
| 336 | 24 & \textcolor{red}{\bf Spline Int. 1} & 0.4 & \textcolor{red}{\bf 0.4} & 0.3 & \textcolor{red}{\bf 0.5} & 1.0 & 1.2 & 1.0 & 1.6 & 4.6 & 1.3 & \textcolor{red}{\bf 1.3} & 1.3 & 1.8 & 5.2 \\
|
|---|
| 337 | 25 & Spline Int. 2 & 0.5 & 0.5 & 0.3 & 0.6 & 1.3 & 1.4 & 0.9 & 1.7 & 5.1 & 1.7 & 1.6 & 1.2 & 2.0 & 6.0 \\
|
|---|
| 338 | 26 & Spline Int. 4 & 0.7 & 0.7 & \textcolor{red}{\bf 0.2 } & 0.7 & 1.5 & 1.7 & \textcolor{red}{\bf 0.8} & 1.9 & 5.3 & 2.0 & 2.0 & 1.0 & 2.2 & 7.0 \\
|
|---|
| 339 | 27 & Spline Int. 6 & 1.0 & 1.0 & 0.3 & 1.0 & 2.0 & 2.0 & \textcolor{red}{\bf 0.8} & 2.2 & 6.8 & 2.6 & 2.5 & \textcolor{red}{\bf 0.9} & 2.7 & 8.4 \\
|
|---|
| 340 | \hline
|
|---|
| 341 | 28 & Dig. Filt. 6 & 0.4 & 0.5 & 0.4 & 0.6 & 1.1 & 1.3 & 1.3 & 1.8 & 5.2 & 1.3 & 1.5 & 1.5 & 2.1 & 6.0 \\
|
|---|
| 342 | 29 & \textcolor{red}{\bf Dig. Filt. 4} & 0.3 & \textcolor{red}{\bf 0.4} & 0.3 & \textcolor{red}{\bf 0.5} & 0.9 & \textcolor{red}{\bf 1.1} & 0.9 & \textcolor{red}{\bf 1.4} & \textcolor{red}{\bf 4.2} & 1.0 & \textcolor{red}{\bf 1.3} & 1.1 & \textcolor{red}{\bf 1.7} & \textcolor{red}{\bf 5.0 }\\
|
|---|
| 343 | \hline
|
|---|
| 344 | \hline
|
|---|
| 345 | \end{tabular}
|
|---|
| 346 | \vspace{1cm}
|
|---|
| 347 | \caption{The statistical parameters bias, resolution and mean error for the algorithms which can be applied to sliding
|
|---|
| 348 | windows (SW) and/or fixed windows (FW) of pedestal events.
|
|---|
| 349 | The first line displays the resolution of the smallest existing robust fixed--window extractor
|
|---|
| 350 | for reference. All units in equiv.
|
|---|
| 351 | photo-electrons, uncertainty: 0.1 phes. All extractors were allowed to move 5 FADC slices plus
|
|---|
| 352 | their window size. The ``winners'' for each column are marked in red. Global winners (within the given
|
|---|
| 353 | uncertainty) are the extractors Nr. \#24 (MExtractTimeAndChargeSpline with an integration window of
|
|---|
| 354 | 1 FADC slice) and Nr.\#29
|
|---|
| 355 | (MExtractTimeAndChargeDigitalFilter with an integration window size of 4 slices)}
|
|---|
| 356 | \label{tab:bias}
|
|---|
| 357 | }
|
|---|
| 358 | \end{table}
|
|---|
| 359 | %}
|
|---|
| 360 | \end{landscape}
|
|---|
| 361 |
|
|---|
| 362 | \clearpage
|
|---|
| 363 |
|
|---|
| 364 | Figures~\ref{fig:sw:distped} through~\ref{fig:df4:distped} show the
|
|---|
| 365 | extracted pedestal distributions for some selected extractors (\#18, \#23, \#25, \#28 and \#29)
|
|---|
| 366 | for one exemplary channel (pixel 100) and two background situations: Closed camera with only electronic
|
|---|
| 367 | noise and open camera pointing to an extra-galactic source.
|
|---|
| 368 | One can see the (asymmetric) Poisson behaviour of the
|
|---|
| 369 | night sky background photons for the distributions with open camera.
|
|---|
| 370 |
|
|---|
| 371 | \begin{figure}[htp]
|
|---|
| 372 | \centering
|
|---|
| 373 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-18-Run38993.eps}
|
|---|
| 374 | \vspace{\floatsep}
|
|---|
| 375 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-18-Run38995.eps}
|
|---|
| 376 | \caption{MExtractTimeAndChargeSlidingWindow with extraction window of 4 FADC slices:
|
|---|
| 377 | Distribution of extracted "pedestals" from pedestal run with
|
|---|
| 378 | closed camera (top) and open camera observing an extra-galactic star field (bottom) for one channel
|
|---|
| 379 | (pixel 100). The result obtained from a simple addition of 4 FADC
|
|---|
| 380 | slice contents (``fundamental'') is displayed as red histogram, the one obtained from the application of
|
|---|
| 381 | the algorithm on
|
|---|
| 382 | a fixed window of 4 FADC slices as blue histogram (``extractor random'') and the one obtained from the
|
|---|
| 383 | full algorithm allowed to slide within a global window of 12 slices. The obtained histogram means and
|
|---|
| 384 | RMSs have been converted to equiv. photo-electrons.}
|
|---|
| 385 | \label{fig:sw:distped}
|
|---|
| 386 | \end{figure}
|
|---|
| 387 |
|
|---|
| 388 |
|
|---|
| 389 | \begin{figure}[htp]
|
|---|
| 390 | \centering
|
|---|
| 391 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-23-Run38993.eps}
|
|---|
| 392 | \vspace{\floatsep}
|
|---|
| 393 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-23-Run38995.eps}
|
|---|
| 394 | \caption{MExtractTimeAndChargeSpline with amplitude extraction:
|
|---|
| 395 | Spectrum of extracted "pedestals" from pedestal run with
|
|---|
| 396 | closed camera lids (top) and open lids observing an extra-galactic star field (bottom) for one channel
|
|---|
| 397 | (pixel 100). The result obtained from a simple addition of 2 FADC
|
|---|
| 398 | slice contents (``fundamental'') is displayed as red histogram, the one obtained from the application
|
|---|
| 399 | of the algorithm on a fixed window of 1 FADC slice as blue histogram (``extractor random'')
|
|---|
| 400 | and the one obtained from the
|
|---|
| 401 | full algorithm allowed to slide within a global window of 12 slices. The obtained histogram means and
|
|---|
| 402 | RMSs have been converted to equiv. photo-electrons.}
|
|---|
| 403 | \label{fig:amp:distped}
|
|---|
| 404 | \end{figure}
|
|---|
| 405 |
|
|---|
| 406 | \begin{figure}[htp]
|
|---|
| 407 | \centering
|
|---|
| 408 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-25-Run38993.eps}
|
|---|
| 409 | \vspace{\floatsep}
|
|---|
| 410 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-25-Run38995.eps}
|
|---|
| 411 | \caption{MExtractTimeAndChargeSpline with integral extraction over 2 FADC slices:
|
|---|
| 412 | Distribution of extracted "pedestals" from pedestal run with
|
|---|
| 413 | closed camera lids (top) and open lids observing an extra-galactic star field (bottom) for one channel
|
|---|
| 414 | (pixel 100). The result obtained from a simple addition of 2 FADC
|
|---|
| 415 | slice contents (``fundamental'') is displayed as red histogram, the one obtained from the application
|
|---|
| 416 | of time-randomized weights on a fixed window of 2 FADC slices as blue histogram and the one obtained from the
|
|---|
| 417 | full algorithm allowed to slide within a global window of 12 slices. The obtained histogram means and
|
|---|
| 418 | RMSs have been converted to equiv. photo-electrons.}
|
|---|
| 419 | \label{fig:int:distped}
|
|---|
| 420 | \end{figure}
|
|---|
| 421 |
|
|---|
| 422 | \begin{figure}[htp]
|
|---|
| 423 | \centering
|
|---|
| 424 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-28-Run38993.eps}
|
|---|
| 425 | \vspace{\floatsep}
|
|---|
| 426 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-28-Run38995.eps}
|
|---|
| 427 | \caption{MExtractTimeAndChargeDigitalFilter: Spectrum of extracted "pedestals" from pedestal run with
|
|---|
| 428 | closed camera lids (top) and open lids observing an extra-galactic star field (bottom) for one channel
|
|---|
| 429 | (pixel 100). The result obtained from a simple addition of 6 FADC
|
|---|
| 430 | slice contents (``fundamental'') is displayed as red histogram, the one obtained from the application
|
|---|
| 431 | of time-randomized weights on a fixed window of 6 slices as blue histogram and the one obtained from the
|
|---|
| 432 | full algorithm allowed to slide within a global window of 12 slices. The obtained histogram means and
|
|---|
| 433 | RMSs have been converted to equiv. photo-electrons.}
|
|---|
| 434 | \label{fig:df6:distped}
|
|---|
| 435 | \end{figure}
|
|---|
| 436 |
|
|---|
| 437 | \begin{figure}[htp]
|
|---|
| 438 | \centering
|
|---|
| 439 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-29-Run38993.eps}
|
|---|
| 440 | \vspace{\floatsep}
|
|---|
| 441 | \includegraphics[height=0.43\textheight]{PedestalSpectrum-29-Run38995.eps}
|
|---|
| 442 | \caption{MExtractTimeAndChargeDigitalFilter: Spectrum of extracted "pedestals" from pedestal run with
|
|---|
| 443 | closed camera lids (top) and open lids observing an extra-galactic star field (bottom) for one channel
|
|---|
| 444 | (pixel 100). The result obtained from a simple addition of 4 FADC
|
|---|
| 445 | slice contents (``fundamental'') is displayed as red histogram, the one obtained from the application
|
|---|
| 446 | of time-randomized weights on a fixed window of 4 slices as blue histogram and the one obtained from the
|
|---|
| 447 | full algorithm allowed to slide within a global window of 10 slices. The obtained histogram means and
|
|---|
| 448 | RMSs have been converted to equiv. photo-electrons.}
|
|---|
| 449 | \label{fig:df4:distped}
|
|---|
| 450 | \end{figure}
|
|---|
| 451 |
|
|---|
| 452 | \clearpage
|
|---|
| 453 |
|
|---|
| 454 | \subsection{ \label{sec:ped:singlephe} Single Photo-Electron Extraction with the Digital Filter}
|
|---|
| 455 |
|
|---|
| 456 | Figure~\ref{fig:df:sphespectrum} shows spectra
|
|---|
| 457 | obtained with the digital filter applied on three different global search windows.
|
|---|
| 458 | One can clearly distinguish a pedestal peak (fitted to Gaussian with index 0)
|
|---|
| 459 | and further, positive contributions.
|
|---|
| 460 | \par
|
|---|
| 461 | Because the background is determined by the single photo-electrons from the night-sky background,
|
|---|
| 462 | the following possibilities can occur:
|
|---|
| 463 |
|
|---|
| 464 | \begin{enumerate}
|
|---|
| 465 | \item There is no ``signal'' (photo-electron) in the extraction window and the extractor
|
|---|
| 466 | finds only electronic noise.
|
|---|
| 467 | Usually, the returned signal charge is then negative.
|
|---|
| 468 | \item There is one photo-electron in the extraction window and the extractor finds it.
|
|---|
| 469 | \item There are more than one photo-electron in the extraction window, but separated by more than
|
|---|
| 470 | two FADC slices whereupon the extractor finds the one with the highest charge (upward fluctuation) of both.
|
|---|
| 471 | \item The extractor finds an overlap of two or more photo-electrons.
|
|---|
| 472 | \end{enumerate}
|
|---|
| 473 |
|
|---|
| 474 | Although the probability to find a certain number of photo-electrons in a fixed window follows a
|
|---|
| 475 | Poisson distribution, the one for employing the sliding window is {\textit{not}} Poissonian. The extractor
|
|---|
| 476 | will usually find one photo-electron even if more are present in the global search window, i.e. the
|
|---|
| 477 | probability for two or more photo-electrons to occur in the global search window is much higher than
|
|---|
| 478 | the probability for these photo-electrons to overlap in time such as to be recognized as a double
|
|---|
| 479 | or triple photo-electron pulse by the extractor. This is especially true for small extraction windows
|
|---|
| 480 | and for the digital filter.
|
|---|
| 481 |
|
|---|
| 482 | \par
|
|---|
| 483 |
|
|---|
| 484 | Given a global extraction window of size $\mathrm{\it WS}$ and an average rate of photo-electrons from the night-sky
|
|---|
| 485 | background $R$, we will now calculate the probability for the extractor to find zero photo-electrons in the
|
|---|
| 486 | $\mathrm{\it WS}$. The probability to find any number of $k$ photo-electrons can be written as:
|
|---|
| 487 |
|
|---|
| 488 | \begin{equation}
|
|---|
| 489 | P(k) = \frac{e^{-R\cdot \mathrm{\it WS}} (R \cdot \mathrm{\it WS})^k}{k!}
|
|---|
| 490 | \end{equation}
|
|---|
| 491 |
|
|---|
| 492 | and thus:
|
|---|
| 493 |
|
|---|
| 494 | \begin{equation}
|
|---|
| 495 | P(0) = e^{-R\cdot \mathrm{\it WS}}
|
|---|
| 496 | \end{equation}
|
|---|
| 497 |
|
|---|
| 498 | The probability to find one or more photo-electrons is then:
|
|---|
| 499 |
|
|---|
| 500 | \begin{equation}
|
|---|
| 501 | P(>0) = 1 - e^{-R\cdot \mathrm{\it WS}}
|
|---|
| 502 | \end{equation}
|
|---|
| 503 |
|
|---|
| 504 | In figures~\ref{fig:df:sphespectrum},
|
|---|
| 505 | one can clearly distinguish the pedestal peak (fitted to Gaussian with index 0),
|
|---|
| 506 | corresponding to the case of $P(0)$ and further
|
|---|
| 507 | contributions of $P(1)$ and $P(2)$ (fitted to Gaussians with index 1 and 2).
|
|---|
| 508 | One can also see that the contribution of $P(0)$ dimishes
|
|---|
| 509 | with increasing global search window size.
|
|---|
| 510 |
|
|---|
| 511 | \begin{figure}
|
|---|
| 512 | \centering
|
|---|
| 513 | \includegraphics[height=0.3\textheight]{SinglePheSpectrum-28-Run38995-WS2.5.eps}
|
|---|
| 514 | \vspace{\floatsep}
|
|---|
| 515 | \includegraphics[height=0.3\textheight]{SinglePheSpectrum-28-Run38995-WS4.5.eps}
|
|---|
| 516 | \vspace{\floatsep}
|
|---|
| 517 | \includegraphics[height=0.3\textheight]{SinglePheSpectrum-28-Run38995-WS8.5.eps}
|
|---|
| 518 | \caption{MExtractTimeAndChargeDigitalFilter: Spectrum obtained from the extraction
|
|---|
| 519 | of a pedestal run using a sliding window of 6 FADC slices allowed to move within a window of
|
|---|
| 520 | 7 (top), 9 (center) and 13 slices.
|
|---|
| 521 | A pedestal run with galactic star background has been taken and one exemplary pixel (Nr. 100).
|
|---|
| 522 | One can clearly see the pedestal contribution and a further part corresponding to one or more
|
|---|
| 523 | photo-electrons.}
|
|---|
| 524 | \label{fig:df:sphespectrum}
|
|---|
| 525 | \end{figure}
|
|---|
| 526 |
|
|---|
| 527 | In the following, we will make a short consistency test: Assuming that the spectral peaks are
|
|---|
| 528 | attributed correctly, one would expect the following relation:
|
|---|
| 529 |
|
|---|
| 530 | \begin{equation}
|
|---|
| 531 | P(0) / P(>0) = \frac{e^{-R\cdot WS}}{1-e^{-R\cdot WS}}
|
|---|
| 532 | \end{equation}
|
|---|
| 533 |
|
|---|
| 534 | We tested this relation assuming that the fitted area underneath the pedestal peak $\mathrm{\it Area}_0$ is
|
|---|
| 535 | proportional to $P(0)$ and the sum of the fitted areas underneath the single photo-electron peak
|
|---|
| 536 | $\mathrm{\it Area}_1$ and the double photo-electron peak $\mathrm{\it Area}_2$ proportional to $P(>0)$. We assumed
|
|---|
| 537 | that the probability for a triple photo-electron to occur is negligible. Thus, one expects:
|
|---|
| 538 |
|
|---|
| 539 | \begin{equation}
|
|---|
| 540 | \mathrm{\it Area}_0 / (\mathrm{\it Area}_1 + \mathrm{\it Area}_2 ) = \frac{e^{-R\cdot WS}}{1-e^{-R\cdot WS}}
|
|---|
| 541 | \end{equation}
|
|---|
| 542 |
|
|---|
| 543 | We estimated the effective window size $\mathrm{\it WS}$ as the sum of the range in which the digital filter
|
|---|
| 544 | amplitude weights are greater than 0.5 (1.5 FADC slices) and the global search window minus the
|
|---|
| 545 | size of the window size of the weights (which is 6 FADC slices). Figure~\ref{fig:df:ratiofit}
|
|---|
| 546 | shows the result for two different levels of night-sky background. The fitted rates deliver
|
|---|
| 547 | 0.08 and 0.1 phes/ns, respectively. These rates are about 50\% lower than those obtained
|
|---|
| 548 | from the November 2004 test campaign. However, we should take into account that the method is at
|
|---|
| 549 | the limit of distinguishing single photo-electrons. It may occur often that a single photo-electron
|
|---|
| 550 | signal is too low in order to get recognized as such. We tried various pixels and found that
|
|---|
| 551 | some of them do not permit to apply this method at all. The ones which succeed, however, yield about
|
|---|
| 552 | the same fitted rates. To conclude, one may say that there is consistency within the double-peak
|
|---|
| 553 | structure of the pedestal spectrum found by the digital filter which can be explained by the fact that
|
|---|
| 554 | single photo-electrons are separated from the pure electronics noise.
|
|---|
| 555 | \par
|
|---|
| 556 |
|
|---|
| 557 | \begin{figure}[htp]
|
|---|
| 558 | \centering
|
|---|
| 559 | \includegraphics[height=0.4\textheight]{SinglePheRatio-28-Run38995.eps}
|
|---|
| 560 | \vspace{\floatsep}
|
|---|
| 561 | \includegraphics[height=0.4\textheight]{SinglePheRatio-28-Run39258.eps}
|
|---|
| 562 | \caption{MExtractTimeAndChargeDigitalFilter: Fit to the ratio of the area beneath the pedestal peak and
|
|---|
| 563 | the single and double photo-electron(s) peak(s) with the extraction algorithm
|
|---|
| 564 | applied on a sliding window of different sizes.
|
|---|
| 565 | In the top plot, a pedestal run with extra-galactic star background has been taken and in the bottom,
|
|---|
| 566 | a galatic star background. An exemplary pixel (Nr. 100) has been used.
|
|---|
| 567 | Above, a rate of 0.08 phe/ns and below, a rate of 0.1 phe/ns has been obtained.}
|
|---|
| 568 | \label{fig:df:ratiofit}
|
|---|
| 569 | \end{figure}
|
|---|
| 570 |
|
|---|
| 571 | Figure~\ref{fig:df:convfit} shows the obtained ``conversion factors'' and ``F-Factor'' computed as~\cite{MAGIC-calibration}:
|
|---|
| 572 |
|
|---|
| 573 | \begin{eqnarray}
|
|---|
| 574 | c_{phe} &=& \frac{1}{\mu_1 - \mu_0} \\
|
|---|
| 575 | F_{phe} &=& \sqrt{1 + \frac{\sigma_1^2 - \sigma_0^2}{(\mu_1 - \mu_0)^2} }
|
|---|
| 576 | \end{eqnarray}
|
|---|
| 577 |
|
|---|
| 578 | where $\mu_0$ denotes the mean position of the pedestal peak and $\mu_1$ the mean position of the (assumed)
|
|---|
| 579 | single photo-electron peak. The obtained conversion factors are systematically lower than the ones
|
|---|
| 580 | obtained from the standard calibration and decrease with increasing window size. This is consistent
|
|---|
| 581 | with the assumption that the digital filter finds the most upward fluctuating pulse out of several. Therefore,
|
|---|
| 582 | $\mu_1$ is biased against higher values. The F-Factor is also systematically low (however with huge error bars),
|
|---|
| 583 | which is also consistent
|
|---|
| 584 | with the assumption that the spacing between $\mu_1$ and $\mu_0$ is artificially high.
|
|---|
| 585 | Unfortunately, the error bars are too high for a ``calibration'' of the F-Factor.
|
|---|
| 586 | \par
|
|---|
| 587 | In conclusion, the digital filter is at the edge of being able to see single photo-electrons,
|
|---|
| 588 | however a single photo-electron calibration cannot yet be done with the current FADC system because the
|
|---|
| 589 | resolution is too poor. These limitations might be overcome if a higher sampling speed is used and the artificial
|
|---|
| 590 | pulse shaping removed. We expect to improve this method considerably with the new 2\,GSamples/s~FADC readout of MAGIC.
|
|---|
| 591 |
|
|---|
| 592 | \begin{figure}[htp]
|
|---|
| 593 | \centering
|
|---|
| 594 | \includegraphics[height=0.4\textheight]{ConvFactor-28-Run38995.eps}
|
|---|
| 595 | \vspace{\floatsep}
|
|---|
| 596 | \includegraphics[height=0.4\textheight]{FFactor-28-Run38995.eps}
|
|---|
| 597 | \caption{MExtractTimeAndChargeDigitalFilter: Obtained conversion factors (top) and F-Factors (bottom)
|
|---|
| 598 | from the position and width of
|
|---|
| 599 | the fitted Gaussian mean of the single photo-electron peak and the pedestal peak depending on
|
|---|
| 600 | the applied global extraction window sizes.
|
|---|
| 601 | A pedestal run with extra-galactic star background has been taken and
|
|---|
| 602 | an exemplary pixel (Nr. 100) used. The conversion factor obtained from the
|
|---|
| 603 | standard calibration is shown as a reference line. The obtained conversion factors are systematically
|
|---|
| 604 | lower than the reference one.}
|
|---|
| 605 | \label{fig:df:convfit}
|
|---|
| 606 | \end{figure}
|
|---|
| 607 |
|
|---|
| 608 |
|
|---|
| 609 |
|
|---|
| 610 | %%% Local Variables:
|
|---|
| 611 | %%% mode: latex
|
|---|
| 612 | %%% TeX-master: "MAGIC_signal_reco"
|
|---|
| 613 | %%% TeX-master: "MAGIC_signal_reco"
|
|---|
| 614 | %%% TeX-master: "MAGIC_signal_reco"
|
|---|
| 615 | %%% End:
|
|---|