\section{CPU Requirements \label{sec:speed}} We tested the speed of the extractors by running them on an Intel\ Pentium\ IV, 2.4\,GHz~CPU machine at IFAE and measured the number of executed events per seconds. This was done using the CPU-time measure features which incorporates each task in MARS. \par The results could easily differ by about 20\% from one try to another (using the same extractor), but in general, the differences between the extractors are much bigger than the intrinsic fluctuation. Table~\ref{tab:cpu} shows the obtained results. The numbers in this list have to be compared to the I/O speed of about 400~evts/sec. of the {\textit{\bf MRead}}-task which performs the reading (and de-compression) of the merpped root-files in MARS. Thus, for time being, every extractor being faster than this reference number does not limit the total event reconstruction speed. Only the integrating spline extractors lie below this limit and would need to be optimized further. \begin{table}[htp] \centering \begin{tabular}{|c|c|c|c|} \hline \hline \multicolumn{4}{|c|}{\large Measured Extraction Speed} \rule{0mm}{6mm} \rule[-2mm]{0mm}{6mm} \hspace{-3mm}\\ \hline \hline Nr. & Name & Events/sec. & comments\\ & & (CPU) & \\ \hline \hline 1 & Fixed Win. (4,4) & 3500--4500 & no time \\ 2 & Fixed Win. (4,6) & 3500--4500 & no time \\ 3 & Fixed Win. (6.6) & 3200--4000 & no time \\ 4 & Fixed Win. (8,8) & 3200--4000 & no time \\ 5 & Fixed W. (14,10) & 2700--3300 & no time \\ \hline 6 & Fix. Win. Spline (4,4) & 1700--2200 & no time \\ 7 & Fix. Win. Spline (4,6) & 1700--2200 & no time \\ 8 & Fix. Win. Spline (6.6) & 1700--2100 & no time \\ 9 & Fix. Win. Spline (8,8) & 1300--1800 & no time \\ 10 & Fix. Win. Spl. (14,10) & 600--1200 & no time \\ \hline 11 & Fix. Win. Peak S. (2,2) & 2300--2900 & no time \\ 12 & Fix. Win. Peak S. (4,4) & 2300--2900 & no time \\ 13 & Fix. Win. Peak S. (4.6) & 2300--2900 & no time \\ 14 & Fix. Win. Peak S. (6,6) & 2300--2900 & no time \\ 15 & Fix. Win. Peak S. (8,8) & 2200--2800 & no time \\ 16 & Fix. Win. Pk S. (14,10) & 2000--2500 & no time \\ \hline 17 & Slid. Win. (2,2) & 400--700 & \\ 18 & Slid. Win. (4,4) & 500--800 & \\ 19 & Slid. Win. (4.6) & 500--800 & \\ 20 & Slid. Win. (6,6) & 1000--1300 & \\ 21 & Slid. Win. (8,8) & 1100--1400 & \\ 22 & Slid. W. (14,10) & 1000--1800 & \\ \hline 23 & Spline Amplitude & 700--1000 & \\ 24 & Spline Int. (1,1.5)& 300--500 & \\ 25 & Spline Int. (2,3) & 200--400 & \\ 26 & Spline Int. (4,6) & 150--200 & to be optimized \\ 27 & Spline Int. (6,9) & 80--120 & to be optimized \\ \hline 28 & Dig. Filt. (6,6) & 700--900 & \\ 29 & Dig. Filt. (4,4) & 700--900 & \\ 34 & Dig. Filt. Pk S. & 500--600 & \\ \hline \hline \end{tabular} \caption{The extraction speed measured for every extractor.} \label{tab:cpu} \end{table} %%% Local Variables: %%% mode: latex %%% TeX-master: "MAGIC_signal_reco" %%% End: