Index: trunk/FACT++/ScriptsForDimCtrl/FeedBackOn
===================================================================
--- trunk/FACT++/ScriptsForDimCtrl/FeedBackOn	(revision 13709)
+++ 	(revision )
@@ -1,123 +1,0 @@
-# dimctrl script
->
-> -------------------------------------------
-> Bias and Feedback StartUp (Current Calibration)
-> -------------------------------------------
-
-.w 2000
-# As a First step we want to calibrate the current, which are read from the bias crate,
-# and not take a DRS calibration, as it is mentioned in the data taking page...
-# so for this we should get the feedback and biasctrl programs into known states
-# I think it is good to try a RECONNECT to the bias, and make sure the voltage is off
-#
-# NOTE:
-# The ideas in the line above are both valid, but both not done.
-# This is *not good*
-
-# Since we do not know, what the feedback program is doing at the moment, we should as well,
-# tell it to keep its mouth shut ... just to be sure, we know whats going on
-> stopping feedback
-FEEDBACK/STOP
-.w 2000
-# stopping should always be possible, and end in state 'Connected'(6)
-.s FEEDBACK 6
-> ..done
-
-#BIAS_CONTROL/RECONNECT
-# If we were disconnected, and this was the first try of the night, the bias_ctrl should
-# be in state 'VoltageOff'(7) more or less immediately
-#.s BIAS_CONTROL 3
-#.s BIAS_CONTROL 7 5000
-# if these assumptions are all wrong, then we might have been properly connected anyway,
-# and just have to ramp down... lets do it, but wait forever, in case it does not work
-> switching off bias
-BIAS_CONTROL/SET_ZERO_VOLTAGE
-.w 2000
-.s BIAS_CONTROL 7
-> ...done
-
-# in case we reach this line, the voltages are all off, and the feedback does not do anything
-# So lets do the current calibration, therefor we tell the bias crate to ramp up just 1 single DAC count(~22mV)
-# the result of this action is, to get bias_ctrl into the state 'VoltageOn'(9), but since we only go one DAC count it shouldn't take long
-> setting bias globally to 1 DAC
-BIAS_CONTROL/SET_GLOBAL_DAC 1
-.w 2000
-.s BIAS_CONTROL 9
-> ...done
-
-# now we may tell the feedback program to calibrate the currents ...
-# I do not understand, if I have to explicitely allow the feedback program to generate output,
-# or if it just produces output...
-# As far as I understand, the feedback output enable status is the same,
-# as it was before I send the STOP command... so it is unknown at this point.
-# and in addition enabling or disabling the output, when STOPed is not possible as far as I know...
-# I try to enable it anyway.
-> enabling output for feedback
-FEEDBACK/ENABLE_OUTPUT yes
-.w 2000
-> ...done
-
-> calibrating bias crate current readings...
-FEEDBACK/CALIBRATE_CURRENTS
-.w 5000
-# in order to find out when the calibration ends, we have to wait for the transistion from state
-# 'Calibrating'(13) back to 'Connected'(6)
-.s FEEDBACK 13
-.s FEEDBACK 6
-
-# Thomas Bretz told me, that the feedback, after this step has disabled its output
-# and is in the mode, we might call 'temperature control' even there is no temerature beeing controlled.
-# I don't know where the voltage is ... in order to perform the calibration, the feedback had to
-# ramp up to 2V below the operational voltage, i.e. about 1V below the breakdown voltage
-
-# We want to take a DRS amplitude calibration so we have to ramp down the bias voltage.
-# this 10sec wait is needed in order for the bias not to disconect all the time...
-> ... current calibration done
-.w 10000
-
-> switching off bias
-BIAS_CONTROL/SET_ZERO_VOLTAGE
-.w 5000
-.s BIAS_CONTROL 7
-> ...done
-
-# now we want to take a run, with dark counts events
-# so we need to ramp up the voltage
-# we want to use the 'current control' more so we give the commands for this...
-> switching on current controll feedback ...
-FEEDBACK/STOP
-FEEDBACK/START_CURRENT_CONTROL 0.0
-FEEDBACK/ENABLE_OUTPUT yes
-# the feedback should be in state 'CurrentControl'(12) now
-.s FEEDBACK 12
-> ... done
-> switching on bias
-# now we give the feedback a hint, that it may ramp ...
-BIAS_CONTROL/SET_GLOBAL_DAC 1
-# after this command the bias_ctrl should be in state 'VoltageOn'(9) after a second or so
-.s BIAS_CONTROL 9
-> ...1 DAC globally set
-# then usually it takes some time until the feedback has enough information to really start controlling the voltage
-# when the feedback actually kicks in, the bias is first in state 'Ramping'(5) for some seconds and finally in 'VoltageOn'(9)
-# again
-.s BIAS_CONTROL 5
-> ...ramping to nominal voltage
-.s BIAS_CONTROL 9
-> ...bias on
-# here we should wait 45 sec in order for the current control to get enough current readings and temp readings to stabilize..
-> waiting 45sec for the current control to stabilize...
-.w 45000
-> ... done
-
-
-# at the end the bias voltage should be ramped down, since in a few seconds a shifter wit ha flashlight
-# will come out to open the shutter...
-> switching OFF bias ... 
-BIAS_CONTROL/SET_ZERO_VOLTAGE
-.s BIAS_CONTROL 7
-> ...done
-> ----------------------------------------------------
-> Bias and Feedback StartUp (Current Calibration)
-> ... done.
-> ----------------------------------------------------
->
Index: trunk/FACT++/ScriptsForDimCtrl/FeedbackOn
===================================================================
--- trunk/FACT++/ScriptsForDimCtrl/FeedbackOn	(revision 13710)
+++ trunk/FACT++/ScriptsForDimCtrl/FeedbackOn	(revision 13710)
@@ -0,0 +1,123 @@
+# dimctrl script
+>
+> -------------------------------------------
+> Bias and Feedback StartUp (Current Calibration)
+> -------------------------------------------
+
+.w 2000
+# As a First step we want to calibrate the current, which are read from the bias crate,
+# and not take a DRS calibration, as it is mentioned in the data taking page...
+# so for this we should get the feedback and biasctrl programs into known states
+# I think it is good to try a RECONNECT to the bias, and make sure the voltage is off
+#
+# NOTE:
+# The ideas in the line above are both valid, but both not done.
+# This is *not good*
+
+# Since we do not know, what the feedback program is doing at the moment, we should as well,
+# tell it to keep its mouth shut ... just to be sure, we know whats going on
+> stopping feedback
+FEEDBACK/STOP
+.w 2000
+# stopping should always be possible, and end in state 'Connected'(6)
+.s FEEDBACK 6
+> ..done
+
+#BIAS_CONTROL/RECONNECT
+# If we were disconnected, and this was the first try of the night, the bias_ctrl should
+# be in state 'VoltageOff'(7) more or less immediately
+#.s BIAS_CONTROL 3
+#.s BIAS_CONTROL 7 5000
+# if these assumptions are all wrong, then we might have been properly connected anyway,
+# and just have to ramp down... lets do it, but wait forever, in case it does not work
+> switching off bias
+BIAS_CONTROL/SET_ZERO_VOLTAGE
+.w 2000
+.s BIAS_CONTROL 7
+> ...done
+
+# in case we reach this line, the voltages are all off, and the feedback does not do anything
+# So lets do the current calibration, therefor we tell the bias crate to ramp up just 1 single DAC count(~22mV)
+# the result of this action is, to get bias_ctrl into the state 'VoltageOn'(9), but since we only go one DAC count it shouldn't take long
+> setting bias globally to 1 DAC
+BIAS_CONTROL/SET_GLOBAL_DAC 1
+.w 2000
+.s BIAS_CONTROL 9
+> ...done
+
+# now we may tell the feedback program to calibrate the currents ...
+# I do not understand, if I have to explicitely allow the feedback program to generate output,
+# or if it just produces output...
+# As far as I understand, the feedback output enable status is the same,
+# as it was before I send the STOP command... so it is unknown at this point.
+# and in addition enabling or disabling the output, when STOPed is not possible as far as I know...
+# I try to enable it anyway.
+> enabling output for feedback
+FEEDBACK/ENABLE_OUTPUT yes
+.w 2000
+> ...done
+
+> calibrating bias crate current readings...
+FEEDBACK/CALIBRATE_CURRENTS
+.w 5000
+# in order to find out when the calibration ends, we have to wait for the transistion from state
+# 'Calibrating'(13) back to 'Connected'(6)
+.s FEEDBACK 13
+.s FEEDBACK 6
+
+# Thomas Bretz told me, that the feedback, after this step has disabled its output
+# and is in the mode, we might call 'temperature control' even there is no temerature beeing controlled.
+# I don't know where the voltage is ... in order to perform the calibration, the feedback had to
+# ramp up to 2V below the operational voltage, i.e. about 1V below the breakdown voltage
+
+# We want to take a DRS amplitude calibration so we have to ramp down the bias voltage.
+# this 10sec wait is needed in order for the bias not to disconect all the time...
+> ... current calibration done
+.w 10000
+
+> switching off bias
+BIAS_CONTROL/SET_ZERO_VOLTAGE
+.w 5000
+.s BIAS_CONTROL 7
+> ...done
+
+# now we want to take a run, with dark counts events
+# so we need to ramp up the voltage
+# we want to use the 'current control' more so we give the commands for this...
+> switching on current controll feedback ...
+FEEDBACK/STOP
+FEEDBACK/START_CURRENT_CONTROL 0.0
+FEEDBACK/ENABLE_OUTPUT yes
+# the feedback should be in state 'CurrentControl'(12) now
+.s FEEDBACK 12
+> ... done
+> switching on bias
+# now we give the feedback a hint, that it may ramp ...
+BIAS_CONTROL/SET_GLOBAL_DAC 1
+# after this command the bias_ctrl should be in state 'VoltageOn'(9) after a second or so
+.s BIAS_CONTROL 9
+> ...1 DAC globally set
+# then usually it takes some time until the feedback has enough information to really start controlling the voltage
+# when the feedback actually kicks in, the bias is first in state 'Ramping'(5) for some seconds and finally in 'VoltageOn'(9)
+# again
+.s BIAS_CONTROL 5
+> ...ramping to nominal voltage
+.s BIAS_CONTROL 9
+> ...bias on
+# here we should wait 45 sec in order for the current control to get enough current readings and temp readings to stabilize..
+> waiting 45sec for the current control to stabilize...
+.w 45000
+> ... done
+
+
+# at the end the bias voltage should be ramped down, since in a few seconds a shifter wit ha flashlight
+# will come out to open the shutter...
+> switching OFF bias ... 
+BIAS_CONTROL/SET_ZERO_VOLTAGE
+.s BIAS_CONTROL 7
+> ...done
+> ----------------------------------------------------
+> Bias and Feedback StartUp (Current Calibration)
+> ... done.
+> ----------------------------------------------------
+>