- Timestamp:
- 08/12/12 20:14:19 (12 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/FACT++/ScriptsForDimCtrl/ResumeDataTaking.dim
r13720 r14338 1 1 #!dimctrl --exec 2 2 3 # DIM_CONTROL: resume data taking after it had to be aborted during first run of four 4 > ---------------------------------------------------------------- 5 > resume taking the 4 data runs after DataTaking was aborted... 6 > ---------------------------------------------------------------- 7 > Operator: make sure bias is switched on and feedback is running!!! 3 # ========================================================================== 4 # resume data taking 5 # ========================================================================== 6 # Script to resume data taking after it had to be aborted 7 # during first run of four data runs 8 9 # call it by: .x ScriptsForDimCtrl/ResumeDataTaking.dim N=<number of runs> 10 # N = 1...4 11 12 # ---------------------------------------------------- 13 14 > ====================================== 15 > resume taking ${N} data runs after 16 > DataTaking was aborted... 17 > ====================================== 18 > OPERATOR: 19 > + make sure bias is switched on 20 > + make sure feedback is running!!! 21 > -------------------------------------- 8 22 9 23 # check if bias is ramped up and if feedback is running 24 25 > ...waiting for BIAS_CONTROL 26 > to be in state 9: VoltageOn 10 27 .s BIAS_CONTROL 9 28 29 > ...waiting for FEEDBACK 30 > to be in state 12: CurrentControl 11 31 .s FEEDBACK 12 32 33 > ...waiting for BIAS_CONTROL 34 > to be in state 9: VoltageOn 12 35 .s BIAS_CONTROL 9 13 > bias is on, and feedback-program is working, but we wait 45sec for the current readings... 36 37 > ...bias is on 38 > ...feedback-program is working 39 > waiting 45sec for the current readings 40 > -------------------------------------- 14 41 .w 45000 15 > ... done 42 43 .j ${N} 16 44 17 45 #Data Taking with Full Trigger Area (4x5min) 46 47 :4 18 48 .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim 19 > taking Data:FullTriggerArea 5min Run 1 ...49 > taking Data:FullTriggerArea 5min Run 20 50 MCP/START 300 -1 data 21 51 .s FAD_CONTROL 8 … … 23 53 > ... done 24 54 55 :3 25 56 .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim 26 > taking Data:FullTriggerArea 5min Run 2 ...57 > taking Data:FullTriggerArea 5min Run 27 58 MCP/START 300 -1 data 28 59 .s FAD_CONTROL 8 … … 30 61 > ... done 31 62 63 :2 32 64 .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim 33 > taking Data:FullTriggerArea 5min Run 3 ...65 > taking Data:FullTriggerArea 5min Run 34 66 MCP/START 300 -1 data 35 67 .s FAD_CONTROL 8 … … 37 69 > ... done 38 70 71 :1 39 72 .x ScriptsForDimCtrl/ServiceScripts/IsReadyForDataTaking.dim 40 > taking Data:FullTriggerArea 5min Run 4 ...73 > taking Data:FullTriggerArea 5min Run 41 74 MCP/START 300 -1 data 42 75 .s FAD_CONTROL 8 … … 44 77 > ... done 45 78 46 > ----------------------------------------------------47 > This is the end of data taking48 > ----------------------------------------------------79 > ====================================== 80 > resumed data taking finished 81 > ====================================== 49 82
Note:
See TracChangeset
for help on using the changeset viewer.