Index: /trunk/FACT++/src/feedback.cc
===================================================================
--- /trunk/FACT++/src/feedback.cc	(revision 17233)
+++ /trunk/FACT++/src/feedback.cc	(revision 17234)
@@ -504,13 +504,15 @@
 
             // Current through ~100 Ohm measurement resistor
-            const double I8 = (adc-fCalibDeltaI[i])*fCalibR8[i]/100;
+            //const double I8 = (adc-fCalibDeltaI[i])*fCalibR8[i]/100;
+            const double I8 = adc-fCalibDeltaI[i];
 
             // Current through calibration resistors (R9)
-                // This is uncalibrated, biut since the corresponding calibrated
+            // This is uncalibrated, but since the corresponding calibrated
             // value I8 is subtracted, the difference should yield a correct value
             const double I9 = fBiasDac[i] * (1e-3/4096);//U9/R9;   [A]
 
             // Current in R4/R5 branch
-            const double Iout = I8 - I9;//I8>I9 ? I8 - I9 : 0;
+            //const double Iout = I8 - I9;//I8>I9 ? I8 - I9 : 0;
+            const double Iout = I8 - I9*100/fCalibR8[i];//I8>I9 ? I8 - I9 : 0;
 
             // Applied voltage at calibration resistors, according to biasctrl