Changeset 20025


Ignore:
Timestamp:
01/04/21 23:48:48 (4 years ago)
Author:
tbretz
Message:
Added updated calibration factor for the three 'special' pixels.
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/Mars/hawc/callisto.C

    r19958 r20025  
    7878    //double scale = 1./22.553;//0.2;
    7979    double scale = 1./17.557;
     80
     81    // Three pixels have a slightly different gain
     82    // so there signal must be attenuated
     83    // THIS ONLY HAS TO BE USED FOR DATA WITH THE RESISTORS IN PLACE!!
     84    MArrayD calib(64);
     85    calib.Reset(1);
     86    calib[33] = 1./0.82;
     87    calib[37] = 1./0.82;
     88    calib[43] = 1./0.82;
    8089
    8190    // ------------------------------------------------------
     
    247256    MCalibrateFact conv5;
    248257    conv5.SetScale(scale);
    249     //conv5.SetCalibConst(calib);
     258    conv5.SetCalibConst(calib);
    250259
    251260    // Instantiate task which applies the DRS time calibration
Note: See TracChangeset for help on using the changeset viewer.