Changeset 2285


Ignore:
Timestamp:
07/17/03 19:00:04 (21 years ago)
Author:
blanch
Message:
Some new commands have been added (qe_file, fadc_outer, nsb_dir_outer)
and some other already obsolete have been removed.
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Simulation/Detector/Camera/input.card

    r1705 r2285  
    11camera 0.6
    2 input_file   ../ReflectorData/Gamma_10_7_11600to11600_w0.rfl
     2input_file   /Data/RefData/Protons/Proton_0/Proton_0_90_4_0to0.rfl
     3#
     4# qe file name
     5qe_file    ../Data/qe-emi-coat.RFL.dat
    36#
    47# Reflector format file that gives the NSB from the stars
     
    1922#
    2023# Directory to look for the NSB database (it should finish with /)
    21 nsb_directory ../Starlight/
     24nsb_directory /Data/StarLight/Fwhm20/
     25#
     26# Directory to look for the NSB database for outer pixels
     27# (it should finish with /)
     28nsb_dir_outer /Data/StarLight/Fwhm20/
    2229#
    2330# Diskriminator and response properties (gate_lentgh, minimum overlaping time,
    2431# amplitude and fwhm) needed for the trigger studies
    25 trigger_prop 6.0 0.25 1.0 2.0
     32trigger_prop 3.0 0.25 1.0 2.0
    2633#
    2734# Trig electronic noise (the width of the gaussian noise is that times
     
    2936trig_noise 0.3
    3037#
    31 # Fadc properties (amplitude and fwhm) needed for the fadc simulation
     38# Fadc properties (integral and fwhm) needed for the fadc simulation
    3239fadc_prop 4.0 5.0
     40#
     41# Fadc properties (integral and fwhm) for the outer pixels
     42fadc_outer 4.0 5.0
    3343#
    3444# Fadc electronic noise (width of the gaussian on top of FADC signal)
    3545fadc_noise 2.0
     46#
     47# Fadc pedestal (50 by default)
     48fadc_pedestal 50.0
    3649#
    3750# Trigger loop mode (theshold, multiplicity and topology)
     
    3952#
    4053# Single trigger mode (theshold, multiplicity and topology)
    41 trigger_single 3.5 4 2
     54trigger_single 4 4 2
    4255#
    4356# Pixels with special trigger threshold (one line for each pixel)
     
    7285#
    7386# Switch on NSB
    74 #nsb_on
     87nsb_on
    7588#
    7689# Switch off NSB
    77 nsb_off
     90#nsb_off
    7891# Number of photons from the diffuse NSB and
    7992# minmum number of phe from shower required to simulate NSB
    80 nsb_mean 0.09 1
     93nsb_mean 0.13 1
    8194#
    8295# Show signal of diskriminator on the screen
Note: See TracChangeset for help on using the changeset viewer.