Index: trunk/MagicSoft/Mars/Changelog
===================================================================
--- trunk/MagicSoft/Mars/Changelog	(revision 3118)
+++ trunk/MagicSoft/Mars/Changelog	(revision 3120)
@@ -23,4 +23,18 @@
    * mcalib/MCalibrationCalc.cc
      - removed initialization of non-used nsamples
+
+   * mcalib/MHCalibrationPixel.[h,cc]
+   * mcalib/MCalibrationPix.[h,cc]
+   * mcalib/MCalibrationCalc.[h,cc]
+     - implemented new histograms: 
+       HSinglePheFADCSlices and HPedestalFADCSlices
+       They are filled with the FADC slice values of either a s.phe. 
+       event or a pedestal event. The decision is taken with the 
+       variable: MCalibrationCalc::fBlindPixelSinglePheCut, to be set 
+       with a setter 
+     - as the blind pixel signal seems to be delayed a bit, the 
+       extraction range is now by default: 10,20. The extractor takes 
+       already care of the fact that part of the signal lies in the 
+       LoGain Sample. 
 
 