Index: trunk/MagicSoft/Mars/Changelog
===================================================================
--- trunk/MagicSoft/Mars/Changelog	(revision 3764)
+++ trunk/MagicSoft/Mars/Changelog	(revision 3768)
@@ -18,4 +18,29 @@
 
                                                  -*-*- END OF LINE -*-*-
+
+ 2004/04/16: Abelardo Moralejo
+   * mcalib/MCalibrationQEPix.[h,cc]
+     - Added fAverageQE. Same role as gkDefaultAverageQE, but can be 
+       changed via SetAverageQE. Made public GetAverageQE and 
+       GetAverageQERelVar (this changes needed for MC).
+
+   * mcalib/MMcCalibrationCalc.[h,cc]
+   * manalysis/MMcCalibrationUpdate.[h,cc]
+     - Adapted to M. Gaug's changes in calibration classes. Behaviour
+       has been tested to be the same as before those changes. Now the
+       conversion factor from ADC counts to photoelectrons, and the
+       average QE (photons->photoelectrons) are calculated independently 
+       (and later combined by MCalibrate to obtain the conversion 
+       ADC->photons).
+
+   * mmain/MEventDisplay.cc, macros/mccalibrate.C, starmc.C
+     - Added call to MExtractSignal::SetSaturationLimit(240)  Affects 
+       only MC display. This was necessary because if electronic noise
+       is simulated in the FADC, sometimes saturated slices look not
+       saturated due to negative fluctuations, so it is better to set 
+       the saturation limit at a safe value (240 ADC counts). Changed 
+       signal integration range (only for MC), now from slices 5 to 10.
+
+
  2004/04/16: Markus Gaug
 
@@ -33,5 +58,4 @@
        into the "low-gain samples" and mislead thus sliding window to 
        be maximized on the tail of the high-gain pulse.
-
 
  2004/04/15: Markus Gaug