Ignore:
Timestamp:
08/23/04 17:56:35 (20 years ago)
Author:
tbretz
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/mimage/MImgCleanStd.cc

    r4716 r4717  
    184184//
    185185//
     186// PROBABILITY CLEANING
     187// ====================
     188// This method takes signal height (over signal noise) and arrival time
     189// into account. Instead of comparing signal/Noise with cleaning level
     190// one and two, we calculate
     191//  - P_ped: The probability that a signal is a pedestal (using
     192//           the signal height and the pedestal) For this probability the
     193//           same algorithm like in kScaled is used (which is a standard
     194//           cleaning which scales the noise with the mean noise of pixels
     195//           with the same size)
     196//  - P_sig: The probability that the signal corresponds to the pixel
     197//           with the highest signal. For this probability we use the
     198//           arrival time only.
     199//
     200// The cleaning now is done in levels of Probability (eg. 0.2, 0.05)
     201// The meaning of the cleaning levels is essentially the same (the same cleaning
     202// algorithm is used) but the cleaning is not done in levels of signal/noise
     203// but in level of this probability.
     204//
     205// This probability is calculated as (1-P_ped)*P_sig
     206//
     207// Example:
     208//
     209// MImgCleanStd clean(0.2, 0.05);
     210// clean.SetMethod(MImgCleanStd::kProbability);
     211//
     212//
    186213// Member Function:  SetMethod()
    187214// ============================
Note: See TracChangeset for help on using the changeset viewer.