Index: trunk/MagicSoft/Mars/Changelog
===================================================================
--- trunk/MagicSoft/Mars/Changelog	(revision 5290)
+++ trunk/MagicSoft/Mars/Changelog	(revision 5291)
@@ -19,4 +19,12 @@
 
                                                  -*-*- END OF LINE -*-*-
+
+ 2004/10/19: Abelardo Moralejo
+
+   * manalysis/MMcCalibrationUpdate.cc
+     - adapted to latest version of Camera simulation, which for stereo
+       configurations creates one MMcConfigRunHeader per telescope,
+       instead of a single one, as it used to be. So now we add the
+       serial number when looking for the container in ReInit.
 
  2004/10/12: Markus Gaug 
Index: trunk/MagicSoft/Mars/manalysis/MMcCalibrationUpdate.cc
===================================================================
--- trunk/MagicSoft/Mars/manalysis/MMcCalibrationUpdate.cc	(revision 5290)
+++ trunk/MagicSoft/Mars/manalysis/MMcCalibrationUpdate.cc	(revision 5291)
@@ -237,8 +237,9 @@
     // header per telescope (it should!)
     //
-    MMcConfigRunHeader* mcconfig = (MMcConfigRunHeader*) pList->FindObject("MMcConfigRunHeader");
+    MMcConfigRunHeader* mcconfig = (MMcConfigRunHeader*) pList->FindObject(AddSerialNumber("MMcConfigRunHeader"));
     if (!mcconfig)
     {
-        *fLog << err << "MMcConfigRunHeader" << " not found... aborting." << endl;
+        *fLog << err << AddSerialNumber("MMcConfigRunHeader") << 
+	  " not found... aborting." << endl;