  • trunk/MagicSoft/TDAS-Extractor/Algorithms.tex

    r5598 r5612  
    310310\end{figure}
    311311
     312\begin{figure}[h!]
     313\begin{center}
     314\includegraphics[totalheight=7cm]{shape_fit_TDAS.eps}
     315\end{center}
     316\caption[Shape fit.]{Full fit to the MC pulse shape with the MC input shape and a numerical fit using the digital filter.} \label{fig:shape_fit_TDAS}
     317\end{figure}
     318
     319
     320\begin{figure}[h!]
     321\begin{center}
     322\includegraphics[totalheight=7cm]{amp_sliding.eps}
     323\includegraphics[totalheight=7cm]{time_sliding.eps}
     324\end{center}
     325\caption[Digital filter weights applied.]{Digital filter weights applied.} \label{fig:amp_sliding}
     326\end{figure}
     327
    312328
    313329
  • trunk/MagicSoft/TDAS-Extractor/Changelog

    r5598 r5612  
    1919
    2020                                                 -*-*- END OF LINE -*-*-
     21
     222004/12/16: Hendrik Bartko
     23  * Algorithms.tex:included new figures:shape_fit_TDAS.eps
     24                                        noise_autocorr_AB_36038_TDAS.eps
     25                                        time_sliding.eps
     26                                        amp_sliding.eps
     27
    2128
    22292004/12/14: Hendrik Bartko
  • trunk/MagicSoft/TDAS-Extractor/Introduction.tex

    r5596 r5612  
    2323
    2424
    25 In order to sample this pulse shape with the used 300 MSamples/s FADC system, the pulse is stretched to a FWHM $>6$ ns (the original pulse is folded with a stretching function of 6ns). Obviously by doing this, more LONS is integrated and thus the performance of the telescope on the analysis level is degraded.
    26 
    27 Because the current MAGIC FADCs have a resolution of 8 bit only, the signals are split into two branches with different gains by a factor of 10. One branch is delayed by 50 ns and then both branches are multiplexed and consecutively read-out by one FADC. % The maximum sustained trigger rate could be 1 kHz. The FADCs feature a FIFO memory which allows a significantly higher short-time rate.
     25In order to sample this pulse shape with the used 300 MSamples/s FADC system, the pulse is stretched to a FWHM $>6$ ns (the original pulse is folded with a stretching function of 6ns). Because the MAGIC FADCs have a resolution of 8 bit only, the signals are split into two branches with different gains by a factor of 10. One branch is delayed by 50 ns and then both branches are multiplexed and consecutively read-out by one FADC. % The maximum sustained trigger rate could be 1 kHz. The FADCs feature a FIFO memory which allows a significantly higher short-time rate.
     26% Obviously by doing this, more LONS is integrated and thus the performance of the telescope on the analysis level is degraded.