trunk/MagicSoft/TDAS-Extractor/Performance.tex
r5322 r5616 3 3 4 4 \subsection{Calibration} 5 6 In this section, we describe the tests performed using light pulses of different colour, 7 pulse shapes and intensities with the MAGIC calibration pulser box. 8 \par 9 The LED pulser system is able to provide fast light pulses of 3--4\,ns FWHM 10 with intensities ranging from 3--4 photo-electrons to more than 500 in one inner pixel of the 11 camera. These pulses can be produced in three colours (``errors'' denote the spectral width): 12 13 \begin{itemize} 14 \item Green: 520$\pm$40\,nm 15 \item Blue: 460$\pm$30\,nm 16 \item UV: 375$\pm$12\,nm 17 \end{itemize} 18 19 Whereas the UV-pulse is very stable, the green and blue pulses show sometimes secondary pulses after 20 about 10--40\,ns from the real pulse. 21 \par 22 Available intensities depend on the involved pulser light colour: 23 \begin{itemize} 24 \item Green: 6 -- 120 phes 25 \item Blue: 6 -- 500 phes 26 \item UV: 3 -- 50 phes 27 \end{itemize} 28 29 One can see that the very stable UV-pulses are unfortunately only available in such intensities as to 30 not saturate the high-gain readout channel. However, the brightest combination of light pulses easily 31 saturates all channels in the camera, but does not reach a saturation of the low-gain channel. 32 \par 33 Our tests can be classified into three subsections: 34 35 \begin{enumerate} 36 \item Stability tests: These include numbers of excluded pixels by the calibration software, 37 numbers of reconstructed photo-electrons and counts of the numbers of outliers from the Gaussian 38 reconstructed charge distributions. 39 \item Linearity tests: These test the linearity of the extractor with respect to pulses of different intensity 40 and colour. 41 \item Time resolution: These tests 42 \end{enumerate} 43 44 \subsubsection{Stability tests} 45 46 \begin{figure}[htp] 47 \centering 48 \includegraphics[height=0.95\textheight]{UnsuitVsExtractor-1LedUV-Colour-04.eps} 49 \caption{Uncalibrated pixels and pixels outside of the Gaussian distribution for a very low 50 intensity pulse.} 51 \end{figure} 52 53 \subsubsection{Linearity tests} 54 55 56 57 \subsubsection{Time resolution} 58 59 60 61 5 62 \subsection{Pulpo Pulses} 6 63 \subsection{MC Data} … … 20 77 %%% mode: latex 21 78 %%% TeX-master: "MAGIC_signal_reco" 79 %%% TeX-master: "MAGIC_signal_reco." 22 80 %%% End:
Note:
See TracChangeset
for help on using the changeset viewer.