Changeset 5706 for trunk/MagicSoft


Ignore:
Timestamp:
01/05/05 15:44:02 (20 years ago)
Author:
hbartko
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/TDAS-Extractor/Reconstruction.tex

    r5702 r5706  
    33The FADC clock is not synchronized with the trigger. Therefore, the relative position of the recorded
    44signal samples varies  from event to event with respect to the position of the signal shape.
    5 The time between the trigger decision and the first read-out sample is uniformly distributed in the range
    6 $t_{\text{rel}} \in [0,3.33)$ ns and can be determined using the reconstructed arrival time
     5The time between the trigger decision and the first read-out sample is uniformly distributed in the range $t_{\text{rel}} \in [0,T_{\mathrm{FADC}}[$, where $T_{\mathrm{FADC}}=3.33 ns$ is the digitization period of the MAGIC 300 MHz FADCs. It can be determined using the reconstructed arrival time
    76$t_{\mathrm{arrival}}$.%directly by a time to digital converter (TDC) or
    87\par