Ignore:
Timestamp:
02/02/05 15:02:35 (20 years ago)
Author:
gaug
Message:
*** empty log message ***
Location:
trunk/MagicSoft/Mars/mjobs
Files:
2 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/mjobs/MJCalibTest.cc

    r6199 r6200  
    129129  MHCamera disp3 (geomcam, "Test;PhotonsPerArea",    "Equiv. Cherenkov Photons per Area");
    130130  MHCamera disp4 (geomcam, "Test;SigmaPhotPerArea",  "Sigma equiv. Cher. Photons per Area");
    131   MHCamera disp5 (geomcam, "Test;Phot",              "Calibrated Photons");
    132   MHCamera disp6 (geomcam, "Test;PhotPerArea",       "Calibrated Photons per Area");
     131  MHCamera disp5 (geomcam, "Test;Phot",              "Calibrated Photons from Fit");
     132  MHCamera disp6 (geomcam, "Test;PhotPerArea",       "Calibrated Photons per Area from Fit");
    133133  MHCamera disp7 (geomcam, "Test;NotInterpolate",    "Not interpolated pixels");
    134134  MHCamera disp8 (geomcam, "Test;DeviatingPhots",    "Deviating Number Photons");
     135  MHCamera disp9 (geomcam, "Test;Arr.Times",         "Mean of calibrated Arr.Times");
     136  MHCamera disp10(geomcam, "Test;SigmaArr.Times",    "Sigma of calibrated Arr.Times");
     137
    135138
    136139  // Fitted charge means and sigmas
     
    152155  disp8.SetCamError(  fBadPixels, 22);
    153156
     157  disp9.SetCamContent(fTestTimeCam,  0);
     158  disp9.SetCamError(  fTestTimeCam,  1);
     159  disp10.SetCamContent(fTestTimeCam,  2);
     160  disp10.SetCamError(  fTestTimeCam,  3);
     161
    154162
    155163  disp1.SetYTitle("Photons");
     
    163171  disp8.SetYTitle("[1]");
    164172 
    165   gStyle->SetOptStat(1111);
    166   gStyle->SetOptFit();
    167 
    168   if (fDisplayType == kNormalDisplay)
    169     {
    170 
    171       TCanvas &c = fDisplay->AddTab("TestCharges");
    172       c.Divide(4,4);
    173      
    174       disp1.CamDraw(c, 1, 4, 2, 1);
    175       disp2.CamDraw(c, 2, 4, 2, 1);       
    176       disp3.CamDraw(c, 3, 4, 1, 1);       
    177       disp4.CamDraw(c, 4, 4, 2, 1);       
    178     }
     173  disp9.SetYTitle("Mean Arr.Times [FADC units]");
     174  disp10.SetYTitle("\\sigma_{t} [FADC units]");
     175 
     176  TCanvas &c = fDisplay->AddTab("TestCharges");
     177  c.Divide(4,4);
     178 
     179  disp1.CamDraw(c, 1, 4, 2, 1);
     180  disp2.CamDraw(c, 2, 4, 2, 1);       
     181  disp3.CamDraw(c, 3, 4, 1, 1);       
     182  disp4.CamDraw(c, 4, 4, 2, 1);       
    179183 
    180184  TCanvas &c2 = fDisplay->AddTab("TestResult");
     
    190194  disp8.CamDraw(c3, 2, 2, 0);       
    191195
    192   return;
    193 
    194 }
    195 
    196 
    197 void MJCalibTest::DisplayResultT(MParList &plist)
    198 {
    199   if (!fDisplay)
    200     return;
    201  
    202196  //
    203   // Update display
    204   //
    205   TString title = fDisplay->GetTitle();
    206   title += "--  Extraction-Calibration-Test-Time";
    207   title += fRuns->GetRunsAsString();
    208   title += "  --";
    209   fDisplay->SetTitle(title);
    210 
    211   //
    212   // Get container from list
    213   //
    214   MGeomCam &geomcam = *(MGeomCam*)plist.FindObject("MGeomCam");
    215  
    216   // Create histograms to display
    217   MHCamera disp1 (geomcam, "Test;Arr.Times",           "Mean of calibrated Arr.Times");
    218   MHCamera disp2 (geomcam, "Test;SigmaArr.Times",      "Sigma of calibrated Arr.Times");
    219 
    220   // Fitted charge means and sigmas
    221   disp1.SetCamContent(fTestTimeCam,  0);
    222   disp1.SetCamError(  fTestTimeCam,  1);
    223   disp2.SetCamContent(fTestTimeCam,  2);
    224   disp2.SetCamError(  fTestTimeCam,  3);
    225 
    226   disp1.SetYTitle("Mean Arr.Times [FADC units]");
    227   disp2.SetYTitle("\\sigma_{t} [FADC units]");
    228  
    229   gStyle->SetOptStat(1111);
    230   gStyle->SetOptFit();
    231 
    232   TCanvas &c = fDisplay->AddTab("TestTimes");
    233   c.Divide(2,4);
    234 
    235   disp1.CamDraw(c, 1, 2,  5, 1);
    236   disp2.CamDraw(c, 2, 2,  5, 1);       
     197  // Display times
     198  //
     199  TCanvas &c4 = fDisplay->AddTab("TestTimes");
     200  c4.Divide(2,4);
     201
     202  disp9.CamDraw(c4, 1, 2,  5, 1);
     203  disp10.CamDraw(c4, 2, 2,  5, 1);       
    237204
    238205  return;
     
    556523  MFillH fill2(&evt2, "MArrivalTime","FillTimes");
    557524 
    558   MFillH fillcam("MHCalibrationTestCam", "MCerPhotEvt");
    559   fillcam.SetNameTab("Test");
    560   MFillH filltme("MHCalibrationTestTimeCam", "MArrivalTime");
    561   filltme.SetNameTab("TestTime");
     525  MFillH fillcam("MHCalibrationTestCam",     "MCerPhotEvt" ,"FillTest");
     526  MFillH filltme("MHCalibrationTestTimeCam", "MArrivalTime","FillTestTime");
     527  fillcam.SetBit(MFillH::kDoNotDisplay);
     528  filltme.SetBit(MFillH::kDoNotDisplay);
    562529
    563530  MFCosmics cosmics;
  • trunk/MagicSoft/Mars/mjobs/MJCalibTest.h

    r6198 r6200  
    5555
    5656  void   DisplayResult(MParList &plist);
    57   void   DisplayResultT(MParList &plist);
    5857
    5958  Bool_t WriteResult();
Note: See TracChangeset for help on using the changeset viewer.