Changeset 6211 for trunk/MagicSoft/Mars


Ignore:
Timestamp:
02/02/05 18:15:03 (20 years ago)
Author:
gaug
Message:
*** empty log message ***
Location:
trunk/MagicSoft/Mars
Files:
4 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/Changelog

    r6210 r6211  
    2222
    2323 2005/02/02 Markus Gaug
     24
     25   * mcalib/MCalibrationChargeCam.cc
     26     - fixed small bug in the display of mean charges when low-gain was
     27       used.
    2428
    2529   * msignal/MExtractor.cc
  • trunk/MagicSoft/Mars/mcalib/MCalibrationChargeCam.cc

    r5876 r6211  
    436436      if (pix.IsExcluded())
    437437        return kFALSE;
    438       val = pix.GetMean();
     438      val = pix.GetConvertedMean();
    439439      break;
    440440    case 1:
    441441      if (pix.IsExcluded())
    442442        return kFALSE;
    443       val = pix.GetMeanErr();
     443      val = pix.GetConvertedMeanErr();
    444444      break;
    445445    case 2:
    446446      if (pix.IsExcluded())
    447447        return kFALSE;
    448       val = pix.GetSigma();
     448      val = pix.GetConvertedSigma();
    449449      break;
    450450    case 3:
    451451      if (pix.IsExcluded())
    452452        return kFALSE;
    453       val = pix.GetSigmaErr();
     453      val = pix.GetConvertedSigmaErr();
    454454      break;
    455455    case 4:
     
    463463      if (pix.GetRSigma() == -1.)
    464464          return kFALSE;
    465       val = pix.GetRSigma();
     465      val = pix.GetConvertedRSigma();
    466466      break;
    467467    case 6:
     
    470470      if (pix.GetRSigma() == -1.)
    471471          return kFALSE;
    472       val = pix.GetRSigmaErr();
     472      val = pix.GetConvertedRSigmaErr();
    473473      break;
    474474    case 7:
  • trunk/MagicSoft/Mars/mjobs/MJCalibTest.cc

    r6207 r6211  
    175175  disp10.SetYTitle("\\sigma_{t} [FADC units]");
    176176 
    177   TCanvas &c = fDisplay->AddTab("TestCharges");
     177  TCanvas &c = fDisplay->AddTab("TestPhes");
    178178  c.Divide(4,4);
    179179 
     
    183183  disp4.CamDraw(c, 4, 4, 2, 1);       
    184184 
     185  /*
     186
    185187  TCanvas &c2 = fDisplay->AddTab("TestResult");
    186188  c2.Divide(2,4);
     
    188190  disp5.CamDraw(c2, 1, 2, 2, 1);
    189191  disp6.CamDraw(c2, 2, 2, 2, 1);       
     192
     193  */
    190194
    191195  TCanvas &c3 = fDisplay->AddTab("TestDefects");
     
    505509
    506510  badcalc.SetNamePedPhotCam("MPedPhotFundamental");
    507   //badtreat.SetUseInterpolation();
     511  badtreat.SetUseInterpolation();
    508512  badtreat.AddNamePedPhotCam("MPedPhotFundamental");
    509513
  • trunk/MagicSoft/Mars/mjobs/MJCalibrateSignal.cc

    r6199 r6211  
    475475    // at the Wuerzburg software meeting 26.01.05
    476476    //
     477#warning Default calibration now in equiv. photo-electrons!
    477478    calib.SetSignalType(MCalibrateData::kPhe);
    478479