    r6579 r6580  
    5555in the image cleaning).
    5656However, only in case of a vanishing bias $B$, the two numbers are equal. Otherwise,
    57 the bias $B$ has to be known beforehand. Note that every sliding window extractor has a
    58 bias, especially at low or vanishing signals $S$.
     57the bias $B$ has to be known beforehand.
     58
     59In the case of MAGIC the background fluctuations are due to electronics noise  and the PMT response to LONS. The signals from the latter background are not distinguishable from the Cherenkov signals. Thus each algorithm which searches for the signals inside the recorded FADC time slices will have a bias. In case of no Cherenkov signal it will reconstruct the largest noise pulse.
     60
     61Note that every sliding window extractor, the digital filter and the spline extractor has a bias, especially at low or vanishing signals $S$.
    5962
    6063\subsection{Linearity}