Index: trunk/MagicSoft/TDAS-Extractor/Conclusions.tex
===================================================================
--- trunk/MagicSoft/TDAS-Extractor/Conclusions.tex	(revision 6658)
+++ trunk/MagicSoft/TDAS-Extractor/Conclusions.tex	(revision 6659)
@@ -45,8 +45,15 @@
 
 Unfortunately, part of our recent data, taken in December~2004 and January~2005 had a severe problem with the pulse location
-within the recorded FADC slices. In the recorded samples, the low-gain pulse situated so far to the right that a part of 
-it has not been recorded any more. This poses severe problems to all extractors which integrate the entire low-gain pulse. 
+within the recorded FADC slices. In the recorded samples, the low-gain pulse is situated so far to the right that a part of 
+it reaches out of the recorded window. This poses severe problems to all extractors which integrate the entire low-gain pulse. 
 We have seen that the spline extractor and the digital filter over 4~FADC slices are still capable to reconstruct the low-gain 
-pulse properly for this partly corrupt data sample.
+pulse properly for this partly corrupt data sample, although the linearity of the reconstructed signal might still be affected above 
+signals of about 300~photo-electrons per pixel.
+
+\par
+
+Special caution has to be made if the F-Factor method is applied for calibration with signal extractors which have an 
+intensity-dependent resolution. This applies especially to the spline algorithms and the digital filter over a window size 
+of 4~FADC slices.
 
 %%% Local Variables: 