Ignore:
Timestamp:
05/13/05 21:25:26 (20 years ago)
Author:
tbretz
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/mjobs/MJCalibrateSignal.cc

    r7028 r7035  
    598598        treat.SetProcessTimes(kFALSE);
    599599
    600     MHCamEvent evt0(0, "PedFLG",     "Fundamental Pedestal from Lo Gain;;P [cnts/sl]");
    601     MHCamEvent evt1(2, "PedRmsFLG",  "RMS from Extractor applied to ped.;;\\sigma_{p} [cnts/sl]");
    602     MHCamEvent evt2(0, "Extra'd",    "Extracted Signal;;S [cnts/sl]");
     600    MHCamEvent evt0(  0, "PedFLG",     "Fundamental Pedestal from Lo Gain;;P [cnts/sl]");
     601    MHCamEvent evt1(  2, "PedRmsFLG",  "RMS from Extractor applied to ped.;;\\sigma_{p} [cnts/sl]");
     602    MHCamEvent evt2(  0, "Extra'd",    "Extracted Signal;;S [cnts/sl]");
    603603    // MHCamEvent evt3(4, "PedPhot",    "Calibrated Pedestal;;P [phe]");
    604     MHCamEvent evt4(5, "PedRMS",     "Calibrated RMS from Extractor applied to ped.;;\\sigma_{p} [phe]");
    605     MHCamEvent evt5(0, "Interp'd",   "Interpolated Signal;;S [phe]");
    606     MHCamEvent evt6(2, "Unsuitable", "Fraction of unsuitable events per Pixel;;[1]");
    607     MHCamEvent evt7(6, "Times",      "Calibrated Arrival Time;;T [fadc sl]");
    608     MHCamEvent evt8(0, "Conv",       "Calibration Conv. Factors;;[phe/fadc cnts]");
    609     MHCamEvent evt9(7, "PulsePos",  "Pulse Position of cosmics (>15phe);;T"); //Calibration Conv. Factors;;[phe/fadc cnts]
    610     /*
    611      MHCamEventTH evt9(6, "PulsePos",  "Pulse Position of cosmics"); //Calibration Conv. Factors;;[phe/fadc cnts]
    612      evt9.SetNameThreshold("MCerPhotEvt");
    613      evt9.SetThreshold(15);
    614      */
    615 /*
    616     evt0.EnableSqrtVariance();
    617     evt1.EnableSqrtVariance();
    618     evt2.EnableSqrtVariance();
    619     // evt3.EnableVariance();
    620     evt4.EnableSqrtVariance();
    621     evt5.EnableSqrtVariance();
    622     evt7.EnableSqrtVariance();
    623     evt8.EnableSqrtVariance();
    624   */
     604    MHCamEvent evt4(  5, "PedRMS",     "Calibrated RMS from Extractor applied to ped.;;\\sigma_{p} [phe]");
     605    MHCamEvent evt5(  0, "Interp'd",   "Interpolated Signal;;S [phe]");
     606    MHCamEvent evt6(102, "Unsuitable", "Fraction of unsuitable events per Pixel;;[1]");
     607    MHCamEvent evt7(  6, "Times",      "Calibrated Arrival Time;;T [fadc sl]");
     608    MHCamEvent evt8(  0, "Conv",       "Calibration Conv. Factors;;[phe/fadc cnts]");
     609    MHCamEvent evt9(  7, "PulsePos",   "Pulse Position of cosmics (>15phe);;T"); //Calibration Conv. Factors;;[phe/fadc cnts]
     610    evt6.SetThreshold();
     611
    625612    MFillH fill0(&evt0, "MPedestalFundamental",       "FillPedFLG");
    626613    MFillH fill1(&evt1, "MPedestalFromExtractorRndm", "FillPedRmsFLG");
Note: See TracChangeset for help on using the changeset viewer.