@13116
|
13 years |
tbretz |
Do only request the status if the voltage is on; get some dummy ...
|
|
|
@13091
|
13 years |
tbretz |
Fixed the averaging implemented yest for more verbose output
|
|
|
@13071
|
13 years |
tbretz |
Set the bias create resistor to 1150 Ohm which (according to the ...
|
|
|
@13070
|
13 years |
tbretz |
Do not send current request in HandleCalibration when still ramping.
|
|
|
@13062
|
13 years |
tbretz |
Updated the resistors. We have now 3900Ohm at the G-APD, 1kOhm serial ...
|
|
|
@13060
|
13 years |
tbretz |
Implemented the possibility of a current feedback which corrects the ...
|
|
|
@12994
|
13 years |
tbretz |
Added the number of events to interpolate to the feedback commands; ...
|
|
|
@12991
|
13 years |
tbretz |
Added quality of service to Deviation
|
|
|
@12990
|
13 years |
tbretz |
Added dim service descriptions
|
|
|
@12900
|
13 years |
tbretz |
Added new states in the feedback which allow to run the temp feedback ...
|
|
|
@12899
|
13 years |
tbretz |
Correction is sent to biasctrl not to feedback -- log-message was wrong.
|
|
|
@12879
|
13 years |
tbretz |
Implemeted a command for gobal feedback; splitted the infoHandler into ...
|
|
|
@12847
|
13 years |
tbretz |
fCalibration must be a float because the service takes floats.
|
|
|
@12840
|
13 years |
tbretz |
fCalibration must be resize to 2*416 not 416
|
|
|
@12825
|
13 years |
tbretz |
Fixed a couple of stupid mistakes introduced with the last commit.
|
|
|
@12805
|
13 years |
tbretz |
Store calibration; implemented command to print a stored calibration; ...
|
|
|
@12716
|
13 years |
tbretz |
Make sure fSP always has a valid size.
|
|
|
@12648
|
13 years |
tbretz |
Fixed a bug which caused the feedback to ramp up the voltages even ...
|
|
|
@12542
|
13 years |
tbretz |
Start the calibration even when the voltage is off
|
|
|
@12417
|
13 years |
tbretz |
Send a last current update request after the calibration is finished ...
|
|
|
@12399
|
13 years |
tbretz |
Added the possibility to calibrate the offset of the currents of the ...
|
|
|
@12351
|
13 years |
tbretz |
Set some fixed control loop parameters as determined in Zurich; output ...
|
|
|
@12350
|
13 years |
tbretz |
Do directly set the new reference in SetReference.
|
|
|
@12347
|
13 years |
tbretz |
Make the FEEDBACK receive the data all the time for a combined control ...
|
|
|
@12319
|
13 years |
tbretz |
Switch control off when voltage off.
|
|
|
@12271
|
13 years |
tbretz |
Added the possibility to apply a global offset to the temperature ...
|
|
|
@12234
|
13 years |
tbretz |
Allow STOP in all states.
|
|
|
@12221
|
13 years |
tbretz |
Debuged temperature feedback.
|
|
|
@12187
|
13 years |
tbretz |
Replaced dic_cmnd_service by DimClient::sendCommandNB.
|
|
|
@12183
|
13 years |
tbretz |
Implemented the possibility to adapt the voltage according to the ...
|
|
|
@12161
|
13 years |
tbretz |
Undo last revision.
|
|
|
@12160
|
13 years |
tbretz |
Added PixelMap.cc to fact_SOURCES
|
|
|
@12067
|
13 years |
tbretz |
Added or updated some text; set default control loop parameters in ...
|
|
|
@12050
|
13 years |
tbretz |
Replaced build in FACTmapV5(a) by a program otpion.
|
|
|
@12047
|
13 years |
tbretz |
Changed name of mapping file; added possibility to set control loop ...
|
|
|
@12028
|
13 years |
tbretz |
|