Back to DataTakingMainPage = Manually Startup, currently not needed == Manually hardware startup on the Island === General Remark - **NEVER** switch off the Agilent Interlock System (black button) - don't operate camera, bias supply and bias crate without the cooling - Note that camera and bias supply will blink in red when the interlock system (black button) is still disabled === Startup 1. Interlock (red button) 1. Cooling (silver button,hold it one sec) 1. Camera (black button) 1. Bias supply (black button) 1. Crate board (green button) 1. Drive == Manually Startup of software and hardware remotely 0. make sure that all needed programs are running ([[preparationdetails#softwarelist list of needed software]]) 0. start GUI (if not already running) - cd ~/operations - ./factGL 0. start Hardware - open the page 10.0.100.100 from a computer in the internal network of La Palma - push Enable Pump to start the Camera - now the Buttons IL_ON, FP, FC, BP, FL should be in state high - push Toggle X, and Toggle Y to start the Drive - Drive is on, when X_OK, Y_OK, Z_OK are in state high - wait a 1-3 minutes, so that the Drive can boot - for further informations about the remote control of the hardware see [[preparationdetails#pdremote here]] 0. start Cosy, if not already running (on aux) - cd ~/Drive/Cosy - ./cosy 0. biasctrl/RECONNECT