= Remote Control of the Hardware **//be aware this whole section might have some mistakes yet, it will be overworked soon//** __Camera and Drive__ - Camera and Drive can be controlled via the page 10.0.100.100 - or the program powerctrl - CAMERA_POWER, starts / stops the Camera - TOGGLE_DRIVE start / stop the Drive __Lid__ - lid can be controlled via the page 10.0.100.26 - or the program lidctrl __Agilent Power Supplies__ - there are 3 Power Supplies: - Interlock: - reachable via 10.0.100.224 - has to switched on - 80 V power supply for the bias crate - reachable via 10.0.100.222 - 50 V power supply for the camera - reachable via 10.0.100.220 __Ethernet Controllable Power Switches__ - there are 3 Switches - Adresses: - 10.0.100.230 - 10.0.100.232 - 10.0.100.234 - Access - on gate:/usr/local/bin/ you can find following scripts to set the state of the switches: - 10_0_100_XXX.pl - commit an option like -on=y/-off=z to it, to set the state of an output channel of the switch