Version 1 (modified by 11 years ago) ( diff ) | ,
---|
Trouble Shooting - Bias
### bias disconnection
Symptom
- biasctrl is in state DISCONNECTED
Solution
- Do _RECONNECT_
- Send a command like _REQUEST_STATUS_
- Sometime the bias crate will disconnect again, do _RECONNECT_
Not Helping
- do not close or kill biasctrl
Symptom
- when biasctrl ramped the voltage, it get in the state OVERCURRENT
Solution
- First try biasctrl/RESET_OVER_CURRENT_STATUS (maybe a few times)
- if it don't help try to ramp the voltage down
- biasctrl/SET_GLOBAL_DAC 0
Not Helping
- do not close or kill biasctrl
### Status notReferenced
Symptom
- biasctrl is in state notReferenced
Solution
- start the Ramping again
- biasctrl/START
Not Helping
- do not close or kill biasctrl
Note:
See TracWiki
for help on using the wiki.