source: trunk/MagicSoft/Mars/NEWS@ 8732

Last change on this file since 8732 was 8724, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 110.3 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Resource file now allow an Include-Resource, i.e. you can
11 read a resource file with default settings, include it in your
12 resource file and overwrite the settings in your file. More than
13 one include file is allowed. Inclusions can be iterative.
14 Include: mydefaults.rc yourdefaults.rc
15 The resources in the first file have higher priority than the
16 second file.
17
18 - general: Now the output files (calib*.root, etc) also contain the
19 resource file (to check it open it in the TBrowser and choose Print()
20 from the context menu)
21
22 - general: Dataset files now allow to overwrite the default path
23 to search for sequence and data files. Note, that the program
24 option and individual resources will overwrite it. For example:
25 SequencePath: /magic/montecarlo/sequences
26 DataPath: /magic/montecarlo/star
27
28 - general: Fixed a problem with variables in MDataPhrase. It seems
29 that only optimdisp (didn't work) was effected.
30
31 - general: Some improvements to the optim and train processing. For
32 example the ststud window now got a proper title.
33
34 - general: The "Status Display: " was removed from the window title
35 within an Eventloop.
36
37 - general: added a new flexible histogram-class (MHn) which can be used
38 for example in testing after optimizations or training to produce
39 user defined histograms.
40
41 - general: The Random Forest now allows attaching an evaluation
42 function which is applied to its output. This allows to train
43 on whatever you like (eg. train on log10(energy), but return
44 energy)
45
46 - general: TheRandom Forest training of energy (trainenergy.c) and
47 disp (traindisp.C) has been improved by more graphical output to
48 judge the result.
49
50 - general: The training of energy (trainenergy.C) has been improved
51 a lot by training on a different quantity than energy. It gives
52 a result which is highly independant of the source spectrum
53 and shows lower bias than all other options.
54
55 - general: Dataset files are allowed to contain collections of
56 datasets. For more details see the class reference of MDataSet.
57
58 - general: The default WobbleMode in a datset file now (if not
59 overwritten) is "auto", i.e. wobble mode is set if the dataset
60 doesn't contain off-sequences.
61
62 - merpp: Merpp can read file format version 9 now. Please realize
63 that for file format version 9 the extraction range is different
64 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
65 the first and last 15 slices have been removed from all MUX data.
66
67 - mars: Similar to writing movies you can now select events which
68 should be displayed in your display. Therefore add the following
69 lines to your mars.rc:
70 MFEvtNumber.FileName: ganymed00223552.root
71 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
72 The input file can be a ganymed-file after (ganymed*.root) or
73 before (ganymed*-summary.root) file. For example to select all events
74 from your on sample after cuts (excluding the ThetaSq cut) use
75 MFEvtNumber.Selector: DataType.fVal>0.5
76 To show all events from your on-sample after quality cuts
77 use the summary file instead.
78
79 - mars: new ways to call mars are implemented. Instead
80 of calling
81 mars filename.root
82 you can now also use
83 mars sequence.txt
84 or
85 mars sequence.txt inputpath
86 or replace sequence.txt by the sequence number if the default
87 sequence file should be used.
88
89 - mars: The default size has been increased
90
91 - mars: There are two new heckboxes which allow to switch off
92 the calculated image parameters
93
94 - callisto: was broken for MCs... fixed.
95
96 - callisto: improved calculation of spline coefficients a lot. This
97 leads to a further improvement of the event rate calibrating MUX
98 data of about 15% (175evt/s instead of 150evt/s)
99
100 - callisto: finally the raw data we read is now real 16bit (with
101 10bit precision) for MUX data and not a stripped 8bit number
102 anymore. Due to scaling of the numbers (without precision loss
103 into an [0-256[ range, the final numbers for pedestal, pedestalrms
104 and extacted signal don't change. However, at all places where
105 raw data is directly accessed (eg. saturation and variation
106 limits in the signal- and pedestal-extraction) the numbers
107 refer still to the data's 16bit range.
108
109 - callisto: The maximum arrival time difference used in the bad
110 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
111 for both, old FADC and MUX-FADC, data.
112
113 - callisto: Be aware that callisto is now calibrating the arrival time
114 in nanoseconds rather than time slices. Also all following tasks
115 have been changed to assume ns units now. If you star data
116 calibrated with an older version it might be necessary to adapt
117 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
118 to obtain optimal results. The plot in the PulsePos tab
119 will now be in ns, too. This might also mean that the Muon
120 analysis in star might not work as perfect as expected as long
121 as old files read in.
122
123 - callisto: The callibration constants of earlier updates got lost
124 somehow. All constants have been updated.
125
126 - star: The PSF is now determined from the profile of the ArcWidth
127 instead of arcwidth/radius. The old way gave to much weight
128 to the bins with low statistics. The reference lines have been
129 updated.
130
131 - star: For speed reasons events suitable for the muon analysis
132 are now also preselected by fConcCOG<0.1 which seems to be a very
133 good preselector for muons.
134
135 - star: is now calculating a new timing parameter the Slope along
136 the major and minor axis of the shower. Therefore a numerical
137 solution of a line-fit is used. To use MHillasExt.fSlopeLong
138 and MHillasExt.fSlopeTrans don't forget to multiply it with
139 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
140
141 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
142 have been removed from MNewImagePar. They have never been good for
143 anything.
144
145 - star: Implemented a new recursive algorithm which is supposed to be
146 faster. Also implemented new cleaning oiptions, which are:
147 + CleanLevel0:
148 The cleaning level above single core pixels can be kept
149 + KeepIsolatedPixels:
150 Define whether single core pixels should be kept
151 + TimeLevel1:
152 The coincidence window in nanoseconds to single used neighbors
153 + TimeLevel2:
154 The coincidence window in nanoseconds to two used neighbors
155 + PostCleanType:
156 MOde in which a time dependent post cleaning should be applied
157 0: No post cleaning
158 1: Require for each used pixels at least one used neighbor
159 within a time-window of CleanLevel1
160 2: Require for each used pixels at least two used neighbor
161 within a time-window of CleanLevel2
162 3: Require first two and second one used neighbor
163 within a time-window of CleanLevel1 and fCleanLevel2
164 respectively
165 + RecoverIsolatedPixels:
166 - recoveres isolated core pixels if they have a used neighbor
167
168 - mars/star: The new default cleaning is:
169 + CleanLevel1: 6.0
170 + CleanLevel2: 3.0
171 + CleanTime1: 1.75
172 + CleanTime2: 1.75
173 + PostCleanType: 3
174
175 - star/ganymed: The old spark-cuts have been replaced by new ones.
176 These new spark cuts have been cross checked with the sequences
177 84720 (before splitter), 101041 (after splitter) and 223539 (new
178 FADCs). In all cases they seperate pretty well, but of course not
179 perfect. Monte Carlos have suggested to tighten the cuts a little
180 bit further at low sizes. This has been done.
181
182 - ganymed: IMPORTANT - The spark cuts have been changed to match
183 all available data more or less well. This might mean that for
184 YOUR data there are still sparks visible.
185 Whenever you do an analysis you have to make sure that NO sparks
186 survive your cuts!
187
188 - ganymed: The old hadronness and size cuts have gotten new indices
189 (10, 11). The old indices 8 and 9 now mean an additional condition
190 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
191 If you want to switch off this cut just move the line far away enough,
192 e.g. by setting c[9] to -500. Please update your ganymed.rc files
193 accordingly!
194 The unit of c[9] is deg. It is the dist at which your cut will
195 cross the slope==0. The unit of the slope is ns/deg. So if
196 you readin files calibrated with an older Mars-version you
197 have to adapt the default value for c[9] to the FADCs:
198 - Multiply by two for the MUX FADCs (run number > 200.000)
199 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
200 - Multiply by 42 for the meaning of life (run number = 200.000)
201
202 - ganymed: The old Cut0 is now called CutQ and is calculated before
203 the source position is caluclated. If you need a quality cut
204 including source dependant data (be very carefull with this!)
205 you have to use Cut0 instead.
206
207 - ganymed: now properly supports three off regions in wobble mode.
208 It will be the default from now on in ganymed_wobble.rc. To change
209 the number of off-regions use
210 NumOffSourcePositions: 1
211 in your ganymed.rc. Also by default no off-theta cut will be done
212 anymore so that you will get a background level higher than the
213 signal level in your ThetaSq plot for ThetaSq>0.2.
214 Due to this be carefull changing the scaling mode away from
215 "None". You will underestimate your signal if your scale interval
216 is not properly set.
217 (Rem: ThetaSqN is no longer needed)
218
219 - ganymed: is now storing the events of all (on- and off-)
220 source positions even in the case of more than one off-source
221 position. This should allow sponde to work properly and the
222 energy estimation is done correctly in all cases (without any
223 "nearest position" trick)
224
225 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
226 with a real pointing model for the starguider is done, calibrated
227 with more than thousand tpoints taken from this date on.
228
229 - ganymed: was broken for Wobble-MCs... fixed.
230
231 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
232 has changed. Note that your old ganymed.rc will be incompatible
233 with the new algorithms! Please check the ganymed.rc files and
234 the class description of MFMagicCuts for more information.
235 It is recommended at the moment to use identical Disp-Parametrizations
236 for on/off- and wobble-mode. If cuts are optimized only
237 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
238 should be optimized. All other values should be kept as they are.
239 If you want to do an anylsis without timing a parameters, you can
240 switch off the timing cuts by seeting parameter 7 to a very small
241 value (eg. -99). To remove the slope parameter from the disp
242 paremtrization set parameter 8 to 0.
243
244 - ganymed: The distribution of observation time versus zenith
245 angle is now shown for off- AND on-data.
246
247 - ganymed: The contents of the source position plot are no longer
248 averaged, thus a lot of (fake) events between the two wobble
249 positions have disappeared.
250
251 - ganymed: There is a new tab "CutT" it contains the VsSize plots
252 with the CutT, whihc is defined in ganymed.rc, applied. It
253 is resonable to use your theta-cut for it, to see if there is
254 something strange (sparks!) in your signal-region.
255
256 - ganymed: To choose a dataset from a collection in a dataset file
257 use the new command line option "--dataset=12345"
258
259 - optim, sponde: should now properly support three off-regions.
260 Just produce your ganymed summary files with three off-regions.
261 optim and sponde will automatically get all off events from
262 all off-regions from this file. Please do not forget to
263 set the scaling in optimwobble.C properly:
264 fit.SetScaleUser(1./3);
265 it is not yet read in automatically (will follow soon).
266 In the case of fixed Scale you can also use
267 cuts.SetThetaCut(MFMagicCuts::kOn);
268 no off-cut needed.
269 Be carefull in case of three off-regions when switching on
270 scale mode. Make sure that the scale interval is set correctly.
271
272 - sponde: sponde.rc and sponde_onoff.rc are now idetical
273
274 - sponde: the resouce files have been rewritten with a lot of
275 comments and a well working parametrization for an energy estimator
276
277 - sponde: In the estimated energy versus monte carlo energy plot the
278 contents where exchanged.... fixed.
279
280 - sponde: the so called "accurate"-mode has been removed. It didn't
281 give any improvement in accuracy, only decreased execution speed.
282
283 - sponde: the so called "simple"-mode has been removed. It didn't
284 give any improvement in simple.
285
286 - sponde: the so called "refill"-mode has been removed. It was anyhow
287 not implemented.
288
289 - sponde: now checks whether the theta distribution of your on-data
290 and the theta-distribution of your Monte Carlo sample (after
291 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
292 sample is incomplete) execution is stopped. Execution can be forced
293 using the new option --force-theta. Use this option with care!
294
295 - sponde: Proper collection areas can now be constructed also from
296 Monte Carlo samples generated with different maximum impact
297 parameters. Note that in previous version you neither got
298 a warning or failure, nor was there any obvious sign that the
299 collection area was overestimated due to usage of files with
300 different maximum impact parameters.
301
302 - sponde: If MC files with different lower energy limits are used
303 the primary MC spectrum is artificially completed down to the
304 lowest energy used at all. WARNING: that this gives correct
305 collection areas ONLY if none of the events in this region would
306 survive your cuts at all.
307
308 - sponde: the output file now contains more information about
309 the spectrum (eg. the full 2D collection area histogram).
310 Note, that this information can only be written to the file
311 if it is stored automatically via command line argument.
312 If you only store the status display from within the display
313 the information is lost.
314
315 - sponde: added a new tab "Energy". It shows the residual of the
316 energy (lg(estimated energy)-lg(monte carlo energy)) versus
317 several parameters and it is meant to judge the quality of the
318 energy estimator. In the ideal case the residual is zero
319 and doesn't depend in the variable. In reality even a good estimator
320 can show residuals versus Monte Carlo energy.
321
322 - sponde: added a new tab "EventDist" showing the unweighted real
323 absolute number of events of your sample after cuts. This tells
324 you how many events with this energy you had in your MC files.
325 The same information you get from the error bars of the weighted
326 histograms, but this is less intuitive.
327
328 - sponde: The spectrum plots now show the crab- and 1553-spectrum
329 for comparison. It is not meant to show these curves in
330 publications, they are only for production.
331
332 - sponde: The OriginalMC tree with the events produced by corsika
333 is now processed only once
334
335 - sponde: Finally fixed most annoying bug, which has effected the
336 last bin of the collection area. It was the problem that binnings
337 of root histograms are from 1 to n (included) but there was a C-like
338 loop in sponde from 0 to n (excluded). Now the loop also includes
339 correctly under- and overflow-bins. The worse thing with this is,
340 that for the events in the highest bin not only the bin-content
341 was wrong, but also the weights applied to these events, which could
342 in pricipal effect also other parts of the distribution (eg. due
343 to energy estimation). Fortunately it effected only a few events
344 in most cases.
345
346
347
348 *** Version 1.2 (2007/05/14)
349
350 - database: The database now has two new values Unsuitable50 and
351 Unsuitable01. They express the number of pixels which are
352 unsuitable for more than 50%, respectively more than 1%, of
353 all calibrated event. It is a more accurate number than the
354 previously used numbers, because they only take the first
355 calibration (ignoring the interleaved calibrations) into account.
356
357 - database: The database now has two other new values UnsuitableMax and
358 DeadMax. They express the maximum number of pixels which were
359 unsuitable, respectively dead, during the sequence. Because
360 of high pedestal rms (cars passing) a few events with very high
361 numbers of unsuitable pixels can happen. Not to suffer from this
362 effect we don't take the highest 0.1% of the numbers into account.
363
364 - general: fixed a bug which caused callisto and star to stop working
365 properly because the callisto output was currupted
366
367 - general: a script called scripts/makemovie has been added which
368 simplified the process of producing several movies from a single
369 sequence with different setup.
370
371 - callisto: Some more code cleanup. Started to remove old obsolete
372 code from cvs.
373
374 - callisto: The extraction of the pedestal with the extractor was
375 not random. It seems that extracting at one position is still biased
376 (for example in the first or last slices we could still suffer from
377 switching noise) Now it is completely random.
378
379 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
380 pedestal files) individual pixels could be skipped due to high
381 variations. This was already the case for the pedestal extraction
382 from the lo-gains since the beginning and properly handled
383 there, but was introduced in the extraction from the pedestal files
384 a while ago. To calculate the average value it was still divided
385 by the number of events procesed not by the number of summands
386 really summed. This let to a pedestal which was a tiny amount too
387 small (for a few piels in the order of 0.1%). This led to an slightly
388 positive offset of the randomly extracted pedestal for a few pixels.
389 I doubt that this has a big effect on the result, because the effect
390 on the individual numbers is quite small. Due to this it is suggested
391 that you rerun your calibration to make sure you are without any
392 avoidable bias.
393
394 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
395 the median rms of the absolute arrival time and expressed in significance
396 levels. This replaces the old meaning of an abolute upper limit. An
397 absolute upper limit doesn't make much sense, because in our data
398 all arrival times are shifted at the same time (in fact it might be
399 a shift of the artificial trigger w.r.t. to the light flash).
400
401 - callisto: Added a new tab "BadPixTm" which shows the time evolution
402 of the number of unsuitable pixels over the whole sequence. This
403 is usefull mainly to judge if an intermediate calibration had
404 problems.
405
406 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
407 of the number of dead pixels over the whole sequence. Dead pixels
408 in this context are unmapped pixels, i.e. pixels which could not
409 be interpolated, and thus are ignored in the further analysis.
410
411 - callisto: It is now possible to use the position of the maximum
412 of the spline as arrival time instead of the leading edge even
413 when using the integral for the signal. Therefor set the extraction
414 type to kIntegralRel ("IntegralRelative") and the relative height
415 ("HeightTm") to -1:
416 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
417 MJPedestalC1.ExtractSignal.HeightTm: -1
418
419
420
421
422 *** Version 1.1 (2007/04/27)
423
424 - general: The new class MGeomCamDwarf contains the camera geometry
425 for our prefered Dwarf camera and can be used to create general
426 geometries of roundish or hexagonal cameras.
427
428 - mars: The default cleaning is now abolute 8.5/4.0.
429
430 - mars: The resource file mars.rc now contains examples for MUX data
431
432 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
433 data containing only 10-bit information is still cooked down to
434 8-bit, by cutting away the lowest 8-bit.
435
436 - merpp: When reading raw data the data is now stored in a single
437 array. The lo-gain array is obsolete. The interface stays the same.
438
439 - callisto: To process the new MUX data use the resource file
440 callisto_mux.rc
441
442 - callisto: The -root and -raw options to read merpped raw data have
443 been removed
444
445 - callisto: If the -mc option is given the sequence-name can now be
446 replaced by the MC sequence number
447
448 - callisto: If the sequence file contains "MonteCarlo: Yes" the
449 -mc option can now be omitted
450
451 - callisto: Started further simplification by removing obsolete
452 dependancies on MCalibIntensity*Cams.
453
454 - callisto: removed unsused intensity calibration from MJCalibration
455 for further simplification
456
457 - callisto: for simplification removed references to
458 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
459 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
460 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
461 (this should at minimum change nothing at all, and at maximum
462 improve thing if these containers where somewhere not handled
463 properly)
464
465 - callisto: Added the option to write an event movie. Please use
466 this option with care (huge files) but exessively to understand
467 our events. For further documentation please refer to the
468 IACT wiki
469 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
470
471 - callisto: Improved binning for the pulse position check histogram
472
473 - callisto: The code calculating the pulse position checknow takes
474 the pedestal into account
475
476 - callisto: The arrival time is now stored with full precision this
477 helps to get rid of artefacts in histograms. For the signal this
478 is not necessray because it is displayed in log-scale anyhow
479
480 - callisto: Fixed a problem with internal exclusions. Pixels which
481 have once been marked as unsuitable didn't get the necessary
482 histograms filled anymore to be rechecked with each interleaved
483 calibration.
484
485 - callisto: The relative arrival time resolution (the rms of the
486 relative arrival time offset) is now checked against its
487 median and the median deviation, instead of the average
488 plus an absolute offset.
489
490 - callisto: The relative arrival time offset is now calculated
491 w.r.t. its median not w.r.t. to an artificial reference pixel.
492
493 - callisto: The relative time calibration now marks pixels with
494 outlaying offset as unsuitable
495
496 - callisto: The interleaved relative time calibration has been switched
497 on. The advantage is that pixels which are marked as outliers
498 now can recover. An improvement over time is not expected, because
499 the relative time calibration seems stable.
500
501 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
502 option can now be omitted.
503
504 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
505 or the option "-mc" is specified as default the monte carlo datacenter
506 paths (/magic/montecarlo/...) are used if not overwritten in the
507 dataset file.
508
509 - ganymed: The output files now contain run- and event-number for all
510 events, accessible as RunNumber.fVal and EvtNumber.fVal
511
512 - ganymed: Added a plot showing the source position in the camera also
513 for wobble mode
514
515 - ganymed: In addition to the existing task which can be setup to
516 be executed after Cut1 a final task called "EstimateEnergy"
517 has been added, executed before writing the final output
518 (ganymed00000000.root). The task setup in all three cases
519 can be choosen individually. (For all three(!) cases you
520 can for example choose MRanForestCalc. For examples see all
521 sponde*.rc and all ganymed*rc)
522
523 - ganymed: If a container "MEstimatedEnergy" is found in the
524 parameter list (eg. because it was setup by MEstimateEnergy)
525 it will be written to the output file.
526
527
528
529 *** Version 1.0 (2007/02/16)
530
531 - database: Website to plot values from the database has been added.
532
533 - database: The rate of spark events as found by star is now kept
534 and the rate after cleaning is now with spark events subtracted
535
536 - general: The changes to the interpretation of phrases lead to
537 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
538
539 - general: Added example files how you can create your own calendar
540 (eg. as christmas present) with Mars. Just run
541 root macros/tutorials/calendar.C
542
543 - general: Added a possibility to display grouped data in the plotdb.C
544 macro (and similar macros). This allows to plot hourly, nightly,
545 weekly, monthly and yearly averages.
546 For more details see the plotall function of the macro
547
548 - general: fixed the error display of the camera display. It showed
549 wrong results.
550
551 - general: fixed a memory leak when reading many MStatusDisplays
552
553 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
554 between a spherical and a parabolic mirror
555
556 - callisto: We have a new pulse position check which takes the properties
557 of the extractor automatically into account. So no need to set
558 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
559 left is done. If possible the lo-gain extraction start and hi-gain
560 extraction end is changed accordingly. If no proper extraction range
561 can be set (hi-gain too much to the left) an error is raised.
562
563 - callisto: New swapped pixels have been found and corrected
564
565 - callisto: Redone the signal extraction this includes:
566 + Unified the algorithms to extract the pedestal for all pedestal
567 extractions done
568 + Unification of hi- and lo-gain into one array
569 + Unification of hi- and lo-gain extraction for Spline and
570 Digital Filter (means now exactly the same algorithm is used,
571 not a copy-and-pasted one)
572 + Store pedestal subtracted data in a common place
573 + Improved extraction algorithms. If the algorithms search a
574 maximum but don't find one they don't return the maximum anymore
575 + Improved the extraction such that a information for signal
576 and time which is consistent is returned
577 + replaced the numerical spline with a (not slower) analytical
578 solution
579 + Lowered the saturation limit from 250 to 245 to make sure that
580 we are far away in all pixels from problems with the clock-noise
581 + The start of the lo-gain extraction is calculated from the hi-gain
582 arrival time. In case of saturation an estimation is used.
583 + the hi-gain window was extended to slice 16. This allows extraction
584 of very late pulses in single pixels or of huge hadron showers.
585 + Now uses the lo-gain extraction range for pedestal extraction,
586 not the hi-gain range in the lo-gain
587
588 - callisto: New hi-/lo-gain calibration constants have been produced
589 for all periods from the statistic of the whole period. They are
590 now used automatically depending on the periods. The old constants
591 where deviation in avarega about 2%-3%. The constants are very
592 stable from period to period (<<1%) except for exchanged channels.
593 In a few cases the constants used so far were off by 1%-2% (maybe
594 temperature effects?)
595
596 - callisto: To gain obsolete space we do not write the
597 MPedestalFundamental anymore. Also calibration and bad pixel
598 treatment is not done for it anymore because it has never been used.
599
600 - callisto: Fixed a bug in the seuqence handling which caused the
601 light condition to be ignored
602
603 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
604 basically the same as "Cleaned" but the distribution devided into
605 the events fullfilling a spark cut or being rejected by it.
606 This cut can be changed from star.rc (see example inside) by
607 the "SparkCut" directive
608
609 - star: Star displays now the average individual pixel-rate (IPR) versus
610 time and the average discriminator threshold (DT) of all pixels.
611
612 - optim: fixed a problem with the optim-macros which was due to a bug
613 in the new phrase parsing
614
615 - ganymed: To get a nice FalseSource plot (instead of the all-information
616 debug plot displayed as a standard plot) use the context menu
617 somewhere between the two upper plots, click on "DrawNicePlot"
618 and enjoy the result. (It is the same context menu which contains
619 the other options)
620 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
621
622 - ganymed/optim/train: The cut program, trainings- and optimization
623 macros could run with less files found than expected from the
624 sequence-files. No the execution is stopped in this case.
625
626 - ganymed: now stores the dataset in the output file with all information
627 contained (as sequence number, sequence path, data path) so that the
628 used dataset file can be recreated complete from the output
629
630 - sponde: now also allows the uasge of random forest
631
632 - sponde: added a plot showing the cut efficiency
633
634 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
635 errors (eg. effecting the collection area) because the errors of the
636 two histograms were swapped in the calculation, which makes a difference
637 in the case the histograms contains weighted events. Aditionally the
638 totalarea was incorrectly taken into account, which results in too small
639 errors, which makes a difference at low statistics were the errors
640 or the collection area dominate.
641
642
643
644 *** Version 0.10.3 (2006/10/23)
645
646 - database: Implemented ObservationMode flag in websites.
647
648 - database: For sequences there is now also the stoptime available on the
649 websites.
650
651 - database: Removed ManuallyChanged flag from sequence-info websites,
652 as it is not needed anymore with the new sequence building algorithm.
653
654 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
655 Class for calculation of confidence intervals (upper limits).
656 Use model 3 or 4 for upper limit calculation for MAGIC observations.
657 Please read the class instruction of TRolke for more information.
658
659 - general: The programs now return 0xfe if the requested resource file
660 doesn't exist.
661
662 - general: Errors comming from root itself are now not output to
663 stderr anymore but to our default (colored) log-stream.
664
665 - general: Changed the interface to TFormula such that now everything
666 is parsed by TFormula, which should allow to use phrases even
667 without paranthesis correctly parsed.
668
669 - callisto: replaced the AdHoc number of effective integration slices
670 in the digital filter by an average of the correct number, averaged
671 over all possible set of weights. This also gives correct numbers
672 for the lo-gains which were totally wrong before.
673
674 - callisto: drastically reduced memory consumption by not storing
675 all intermediate calibration results in memory anymore (we might
676 write them into a file in the future)
677
678 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
679 debug plot displayed as a standard plot) use the context menu
680 somewhere between the two upper plots, click on "DrawNicePlot"
681 and enjoy the result. (It is the same context menu which contains
682 the "DrawAll" option)
683 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
684
685
686
687 *** Version 0.10.2 (2006/10/15)
688
689 - general: changed the building of the sequence files such, that
690 the source-/project name in case of wobble-sources is not the
691 source/project of the first data run anymore but the new generalized
692 wobble source/project
693
694 - general: Added some functions to MAstro to calculate sun and
695 moon properties
696
697 - general: Added two new macros (starvisday.C and starvisyear.C)
698 which allow to plot the visibility of several stars in one day
699 or of one star along one year
700
701
702
703 *** Version 0.10.1 (2006/10/11)
704
705 - general: HTML logging output was distorted... fixed.
706
707 - general: Changed the writing of the sequencefiles such that only
708 as many pedestal files as giving at least 1000 pedestal events which
709 are nearby the first calibration run are used as pedestal runs
710
711 - sponde: In the calculation of the collection area(s) and the
712 distribution for MOnte Carlo and estimated energy the error
713 calculation was wrong because root didn't take the errors
714 properly into account... fixed.
715
716
717
718 *** Version 0.10 (2006/10/10)
719
720 - general: all executables now check consistency of the root version
721 installed with the root version used for compilation. The return
722 code in this case is 255.
723
724 - general: The algorithm to build seqeunces has been redesigned
725 completly. It is now more flexible in terms of a resource file
726 resources/sequences.rc which can be used to partly overwrite
727 the default algorithm and defined the important part of the
728 algorithm. It also takes correctly into account several ways
729 of taking wobble-data. Currently the new algorithm doesn't take
730 the number of pedestal events anymore into account (so a sequence
731 could have much less than 1000 pedestal events and data runs are
732 no-more used instead)
733
734 - general: a lot of small changes to make the code compatible with
735 root 5.12/00 and gcc 4.1
736
737 - general: Fixed some warnings thrown if more warnings are switched
738 on in the compiler
739
740 - general: Added a function to MMath which returns the Median of
741 the distribution abs(y[i]-median) but at 68:32 division instead
742 of 50:50, which is somehow the median counterpart of the rms.
743
744 - general: MAstroCatalog allows now to read calatog files (as bsc5)
745 even if they are compressed with gzip (recommended compression
746 is with "-1")
747
748 - showplot:
749 + batch mode creation of image files now works with root 5.12/00
750 + added support for writing bmp (though it never produces
751 bmp which can be read by programs like xv or gimp)
752 + added support for xml
753 + added new option to start the display with a different size, by
754 --display-width=nnn or --display-height=nnn
755 + added options to define the canvas size when the display is started
756 --canvas-width=nnn or --canvas-height=nnn
757 the option can also be used for batch-mode conversion
758 + added an option which automatically fits the display size to the
759 desktop-size: --auto-size
760
761 - merpp: didn't recognize files with the extension .raw.gz - fixed.
762
763 - merpp: allow the reports to have 1000ms due to a bug in the camera
764 program.
765
766 - callisto: New swapped pixels have been found and corrected. For
767 details see MRawRunHeader::FixAssignment()
768
769 - callisto: Callisto now raises an error if one of the input files could
770 not be opened.
771
772 - callisto: In some rare cases it could happen that in the signal
773 extraction of the digital filter the extractor returned nonsense
774 results due a wrong initializion of a variable (this happens in
775 cases in which the extracted signal is exactly zero or the
776 digital filter couldn't slide because of a too small extraction
777 window, which could happen in the lo-gain extraction)
778
779 - callisto: The lo-gains have been marked as valid in some cases
780 when they got not extracted at all (deltsumlo=deltatimelo=0) because
781 the allowed extraction range (fLoGainLast-fLoGainFirst) was
782 smaller than the number of slices (fLoGainWindowSize) needed
783 by the lo-gain extractor
784
785 - callisto: Updated absolute calibration constants (muon calibration)
786
787 - callisto: fixed a bug which caused the hi-gain saturation not
788 to be handled properly in the spline (the position of the
789 saturation was calculated incorrectly)
790
791 - callisto: fixed a bug which gave weird results if hi- _and_
792 lo-gain could not be extracted properly. In some cases hi-
793 and lo-gain have not been extracted at all and the random result
794 got calibrated. In other cases the hi-gain was saturating and the
795 lo-gain has not been extracted. For this a completly arbitraty
796 scale factor was applied to the result from extracting the
797 charge of the saturating hi-gain.
798
799 - callisto: improves handling of extracted signal if lo- and/or
800 hi-gain could not be extracted properly. If no appropriate
801 calibration of either the signal or the arrival time is possible
802 the pixel is now markes as unsuitable instead of estimated.
803
804 - callisto: Fixed a problem in the spline extraction which gave
805 weird results if the signal was extracted from the first (and
806 highest) slice (as a workaround extraction from the first
807 slice has been forbidden)
808
809 - callisto: Fixed a bug regarding the use of the QE which doesn't
810 effect the result because the default is used anyhow.
811 (The bug was there since 14/07/2005)
812
813 - callisto: Changed the default for fgLoGainStartShift to -2.4
814
815 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
816 factors to be always 10 for all pixels as soon as the first
817 calibration update has happend.
818
819 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
820 was off by more than one slice (which gives wrong values for
821 pixels which have saturated the hi-gain) This was a problem
822 mainly for timing studies, not so much for the automatic standard
823 analysis. Also the values for the Spline have been changed slightly:
824 + Digital Filter from 1.70 to 0.95
825 + Spline from 1.39 to 1.30
826 The numbers were sorted out by an extensive test in the
827 test-database.
828
829 - callisto: Removed the tab showing the average calibrated arrival
830 time. It never gave useful information.
831
832 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
833 lo-gain pulse for data pulses if hi- and lo-gain have saturated
834 and both were extracted because the hi-gain was above the
835 LoGainSwitch.
836
837 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
838 lo-gain pulse position (after application of LoGainOffset, which
839 means in the ideal case it is 0) for data pulses if hi- and lo-gain
840 have saturated and both were extracted because the hi-gain was above
841 the LoGainSwitch.
842
843 - callisto: After extensive tests a new threshold level for determination
844 of the pulse position has been found at 50phe. This is due to the
845 fact that for lower pulses the arrival time changes its average
846 behaviour dramatically. It tends to the average of the extraction
847 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
848
849 - callisto: Added two more plots to the calibration part. The average
850 extracted signal and the average extracted arrival time as
851 extracted by the signal extractor (This can help debugging problems
852 because it doesn't involve a fit)
853
854 - star: changed the fit for the effective on time such that initial
855 values are calculated automatically now instead of using build
856 in values. This makes the fit more indepedant of the underlaying
857 rates. With a test of ~350 sequences in the test database it could
858 be shown that the new fit gives the same result +/-1sek.
859 The highest deviation was +5s the lowest -10s. You can now control
860 the bahaviour with two resource values:
861 MHEffectiveOnTime.FistBin: 3
862 MHEffectiveOnTime.NumEvents: 12000
863 Use FirstBin=1 and NumEvents=120 to fit the effective on time
864 from the resulting gamma candidates
865
866 - star: The Center histogram in MHHillas is now by default displayed
867 with the colz draw-option
868
869 - ganymed: now produces valid error codes if failed
870
871 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
872 with the option "hadronness" instead of "area" or "both" if
873 you want to use both cuts. The hadronness cut includes a fixed
874 cut in hadronness (index 8) and a fixed cut in size (index 9).
875
876 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
877 the M3Long of the anti source to be not properly evaluated
878 (actually is was evaluated as a unique random number) in case
879 of optimization with anti-theta cut switched on. This might have
880 lead to improper, but not necessarily wrong, optimization results.
881
882 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
883 how to use random forest
884
885 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
886 ganymed_onoff.rc. Seems to be unintentional that they were different.
887
888 - sponde: Since the introduction of the possibility to define a
889 normalization energy instead of using the integral the default
890 was not using the integral anymore but a normalization energy of
891 1GeV. It is now the integral again.
892
893 - sponde: Fixed a problem in the weighting which did not allow
894 a MC slope of -1.
895
896
897
898 *** Version 0.9.6 (2006/05/24)
899
900 - general: changed the binning of the azimuthal profile of the camera
901 such that it is aligned with the 60deg boundaries.
902
903 - merpp: better handling of problems with the TH, TD part of the
904 CC-REPORT for files older than 200507190 and 200412210
905 respectively
906
907 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
908
909 - merpp: implementd latest changes in starguider reports (sinc 9th May)
910
911 - callisto: if an arrival time is extracted outside the fadc range is
912 was set to the boundary before. Now a random number is assigned
913 instead to avoid unfortunate coincidences of arrival times just
914 by this arbitrary value.
915
916 - callisto: added a new option to callisto.rc which allows
917 to set the maximum arrival time difference allowed for the
918 badpixel algorithm to determin whether a pixels belongs to a shower:
919 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
920
921 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
922 to 0.9 as suggested by Stefan due to a recent study on the fraction
923 of pixels surviving the image cleaning
924
925 - callisto: switched off error in case of "pulse is too much to the left"
926
927 - callisto: The extraction window is not adapted anymore. This means that
928 the pulse is extracted from the full range. The draw-back is that the
929 background (pedestal) will become slightly higher. Switching on/off
930 the PulsePosCheck in the callisto.rc only effects filling the
931 histograms.
932 WARNING: If the pulse is too much to the left data is calibrated!
933 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
934 in the database to make sure that your data is valid!
935
936 - star: Show also the number of stars correlated correctly by the
937 starguider
938
939 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
940 than one off-source region in wobble-mode. To use it add the following to
941 your ganymed_wobble.rc:
942 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
943 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
944 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
945 + Cut1.ThetaCut: None
946 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
947
948 - ganymed: in the case the latest report is older than a default (currently
949 one minute) and the current report will be skip the starguider
950 correction and calibration will be reset. The maximum age can be
951 setup from ganymed.rc by (minutes):
952 MPointingDevCalc.MaxAge: 1.5
953
954 - ganymed: A first implementation showing all size-bins for the theta-sq
955 resp. alpha-plots in a single tab automatically
956
957
958
959 *** Version 0.9.5.1 (2006/05/05)
960
961 - general: Added a new option "zdiff" to the Makefile which runs
962 "cvs diff" as "make diff" would do, but with compression
963
964 - general: accelerated MTFillMatrix (used for eample in all training
965 and optimization macros) by skipping some obsolete calles in the
966 eventloop the first and second loop could be accelerated by ~20%
967
968 - general: Added a missing feature in the MFilterList class which
969 prevented MFEnergySlope from working correctly in trainenergy.C
970
971 - general: Accelerated the random forest training and usage a bit
972
973 - merpp: Adapted to new raw data file format version 6
974
975 - merpp: fixed a problem with reading the starguider reports
976 after 6.3.2006
977
978 - callisto: At some times six pixels had to be exchanged manually in the
979 data. If the pixels to be swaped are both not found, an error was raised
980 and calibration was stopped. Now it is assumed they are intentially not
981 mapped and the Error has been changed to a Warning.
982
983 - star: Added new image cleaning based on the arrival time of the shower.
984 The new cleaning can be accessed using the parameter "Time" instead of
985 the the old one (like "Absolute) in the star.rc-file.
986 Recommended parameters:
987 + MImgCleanStd.CleanLevel1: 8.2
988 + MImgCleanStd.CleanLevel2: 5
989 + MImgCleanStd.CleanRings: 2
990 + MImgCleanStd.KeepSinglePixels: No
991
992 - star: Simplified the calculation of the effective on time. By letting
993 the fit start in the third bin the result should become more stable.
994 The fit quality is now ignored for the theta-plot which is not used
995 in the analysis later. Still better pre-cut which, for example,
996 remove events triggered by car-light (rate changing on a short
997 time-scale) are missing.
998
999 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1000 for optimization (kWeakSource) which is suggested by the Berlin
1001 people for weak sources.
1002
1003 - macros: plotdb.C:
1004 + if no dataset and no time-interval is given only sequences with
1005 an effective on-time above five minutes are plotted anymore
1006 + added a new tab "RelTime" displaying the relative on-time
1007 (effective on-time divided by the observation time)
1008
1009 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1010 the optimization became a lot faster
1011
1012 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1013 To display them just delete the pads displayed on top.
1014
1015 - ganymed: fixed a bug which could cause strange behaviour in wobble
1016 mode if no starguider information was available due to an incorrect
1017 initialization of the starguider calibration
1018
1019 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1020 be changed from within the plot. It can also be setup from the
1021 resource file using:
1022 + MHDisp.fScaleMin: 0.325
1023 + MHDisp.fScaleMax: 0.475
1024
1025 - ganymed, showplot: Fixed a problem with the fit to the off-data
1026 (HistOff) which could cause a time lag or an inifinite loop.
1027 The bug did not effect the results at all.
1028
1029 - sponde: Added a new tab showing the effective collection area after
1030 trigger (including the software trigger)
1031
1032 - sponde: MMcSpectrumWeight has a new option which allows to define
1033 the scaling factor not by the integral of the events but at
1034 a defined energy:
1035 e.g. MMcSpectrumWeight.NormEnergy: 200
1036
1037 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1038 eventloops the loop could be accelerated by ~20%
1039
1040
1041
1042 *** Version 0.9.5 (2006/03/13)
1043
1044 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1045 and added the standard Disp-parametrization
1046
1047 - macros: added a new macro datacenter/macros/plotstat.C allowing
1048 to plot statistics about the data processing
1049
1050 - macros: added a new macro to plot the muon correction coefficients
1051 versus period (macros/plot/mucal.C)
1052
1053 - showplot: path inflation for ganymed files was broken
1054
1055 - callisto: Fixed an important bug. When the number of saturating pixels
1056 were calculated the bad pixel information already available from the
1057 calibration was ignored. This yields wrong values in case pixels
1058 are broken and saturate all the time or randomly.
1059
1060 - callisto: Updated Muon calibration constants. Spline data now also uses
1061 different values for different periods
1062
1063 - star: The time-evolution shown in the effective on-time plot now displays
1064 the axis range (if there are no holes it should be similar to the
1065 effective on-time)
1066
1067 - star: Added two new image parameters:
1068 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1069 the three pixels next to the center of gravity and the size
1070 + MNewImagePar.fConcCore: The ratio of the signals of all
1071 pixels inside or touching the ellipse and the size
1072
1073 - ganymed: now stops in requested source isn't found in catalog file
1074
1075 - ganymed: Many improvements to the phi-plot in wobble mode:
1076 + with a template the ideal background is displayed
1077 + a possible camera inhomogeneity is taken into account
1078 + the anti theta cut is better supported
1079 + the phi cut is automatically calculated from the theta cut
1080 See the examples in ganymed_wobble.rc for more details.
1081
1082 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1083 times the bin-width instead of the absolute energy
1084
1085 - ganymed: New cuts for on/off and wobble mode
1086
1087 - ganymed: The smearing of the False Source plot has been increased
1088 to 0.06
1089
1090 - ganymed: The starguider calibration can now be changed from the
1091 resource file.
1092 See the examples in ganymed*.rc for more details.
1093
1094 - ganymed: added a new option for on-/off-observations
1095 MJCut.RandomSourcePosition
1096 If switched on the distribution of observation time of the source
1097 position in the camera is calculated from the on-data and randomly
1098 applied with this distrbution to the off-data.
1099
1100 - ganymed: by skipping some obsolete calles in the eventloop the
1101 first and second loop could be accelerated by ~20%
1102
1103 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1104 position in the off-data randomly according to its distribution in the
1105 on-data.
1106
1107
1108
1109 *** Version 0.9.4.3 (2006/02/13)
1110
1111 - general: Fixed a bug in most of the programs which prevented the
1112 compile date in the startup message to be displayed
1113
1114 - general: Simplified program calls. The following abbreviations
1115 are now possible:
1116 showlog callisto 55599
1117 showplot signal 55599
1118 star 55599
1119 callisto 55999
1120 ganymed 2
1121 In this cases the corrsponding root-, log-, sequence- or dataset-
1122 filename is automatically compiled using the default datacenter
1123 paths ("/magic/*")
1124
1125 - general: Fixed a long outstanding bug which made axis tick marks
1126 disappear if MDataFormula was used (eg. abs(x))
1127
1128 - general: Updated MMath with new functions to calculate the results of
1129 a exponential, logarithmic and powerlaw fits analytically.
1130
1131 - general: Updated some macros with comments:
1132 + macros/optim/optimdisp.C
1133 + macros/optim/optimenergy.C
1134 + macros/optim/optimwobble.C:
1135
1136 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1137 files) now allows adding a pre-cut like in the optimization. E.g. this
1138 is useful to perform g/h-separation cuts before training the random
1139 forest.
1140
1141 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1142 correctly assigned in the raw data assignement table. A fix to correct
1143 the assignment tabel have been implemented.
1144
1145 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1146 by 90, 180 and 270 deg.
1147
1148 - general: the macro plotdb.C now allows to highlight sequences belonging
1149 to a datset. For more details see the descritions in the macro.
1150
1151 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1152 of the display, it gave wrong results espacially for big sizes.
1153 Now the embedded canvas should always have a ratio width/height=3/2.
1154 The "Size" options have been updated with values fitting the 3/2
1155 size ratio.
1156
1157 - RanForest:
1158 + Updated the random forest classes to support also the
1159 regression method implemented by Thomas H.
1160 + added new tutorial macro how to train the random forest
1161 for energy estimation (macros/optim/rfenergyest.C)
1162 + new classes to train the random forest (still in development)
1163 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1164 + new tutorial macros for random forest training in macros/train
1165 trainenergy.C, traindisp.C, trainseparation.C
1166
1167 - mars: now allows to setup a cut in the resource file mars.rc to choose
1168 the events to be displayed, eg:
1169 Cut.Condition: {0} && {1}
1170 Cut.0: MHillas.fSize>100
1171 Cut.1: MHillas.fSize<900
1172
1173 - merpp: Made aware of the new .rep format 200510250. This includes
1174 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1175 the discriminator thresholds (MCameraTD) and the disciminator
1176 delays (MCameraTD). All of them come with the CC report and are therefor
1177 written to the CC tree.
1178
1179 - callisto: fixed a bug in the calculation of the arrival times in
1180 the Digital Filter. They were all shifted by the same amount
1181 fHiGainFirst. This caused an offset in the order of the position of
1182 the left border of the extraction window in the times calculated
1183 from high-gain and from low-gain. The bug effected only the absolute
1184 arrival times. The bug was there since 30.1.2005.
1185
1186 - callisto: Changed the ExtractionWindow for the pulse position check
1187 such that the camera inhomogeneity becomes as less as possible and
1188 comparable to the pulso position check switched off. More details
1189 on the study will be given at our result web-page.
1190
1191 - ganymed: ganymed.rc, ganymed_onoff.rc:
1192 changed to new cuts trained with 1ES1218 and Crab-data
1193 for maximum sigma*log10(excess)
1194
1195 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1196 a new option was implemented to estimate Disp (CalcDisp)
1197
1198 - ganymed: Implemented two new options which allow
1199 to overwrite the default path to search for the sequence files
1200 --ins=/magic/sequences
1201 and where to search for the image data
1202 --ind=/magic/data/star
1203
1204 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1205 dx/dy from the resource file by
1206 MSrcPosCorrect.Dx
1207 MSrcPosCorrect.Dy
1208
1209 - ganymed: fixed reading the source catalog. Only as many chars
1210 as the requested source name had were compared (If a source
1211 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1212 were requested it could happen that the coordinates of
1213 "1ES1218" were read) The source coordinates are now printed
1214 in addition to its name to the logging output.
1215
1216 - ganymed: changed the background fit in the case of a ThetaSq function
1217 from a polynomial to a exponential, this should give a big improvement
1218 for on-only analysis'
1219
1220 - ganymed/sponde: Calculation of the error of single size-/energy-
1221 bins now uses Li/Ma (5) instead of LiMa (17)
1222
1223 - sponde: Added a plot E^2*dN/dE
1224
1225 - sponde: The energy estimator plot should now show values like
1226 they are commonly used.
1227
1228 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1229 (a powerlaw with cutoff didn't work before)
1230
1231
1232
1233 *** Version 0.9.4.2 (2005/10/01)
1234
1235 - general: added new tutorial macro macros/tutorials/threshold.C:
1236 how to calculate the threshold
1237
1238 - general: added a new game. Start it from the interpreter with
1239 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1240 and MagicReversi)
1241
1242 - general: neighbor pixels in MGeoms are now sorted clockwise
1243
1244 - merpp: made aware of new format 20050829-0
1245
1246 - callisto: New scale factors from muon analysis, stored in new
1247 resource file resources/calibration.rc
1248
1249 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1250 the eventloop if something went wrong. This is necessary for the
1251 automatic processing
1252
1253 - callisto: Implemented a new treatment for the time information
1254 developed by S.Ruegamer, this should give much better response than
1255 the old very primitive algorithm. This is especially important
1256 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1257 treatment was buggy! As neighbor pixels to interpolate the
1258 arrival times always the pixels 0 to 5 were taken)
1259
1260 - callisto: In addition to the new treatment of arrival times the
1261 decision of the treatment whether a pixel contains shower
1262 information or not is used to improve the signal interpolation
1263 further. Previously interpolated pixels showed a non-zero signal
1264 do the peak searching signal extractors. Having a signal pixel
1265 beside raised the signal above the cleaning level. Thus the
1266 pixel survived cleaning to often but with a too low mean signal.
1267 By replacing empty pixels with a gaus (mean and rms from the
1268 corresponding Area entries in MPedPhotCam) this effect can
1269 be supressed.
1270
1271 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1272 got lost when the events were stored by the calibration... fixed.
1273 (This was no problem for normal image cleaning because the pixel
1274 content was artificially set to 0 not surviving standard cleaning
1275 algorithm)
1276
1277 - callisto: Fixed a bug which caused the random and peak-search pedestal
1278 extracted with an extractor to be exchanged for the first (roughly)
1279 500 events (*Extractor and *ExtractorRndm).
1280 (They were simply exchanged in callisto.cc) This bug might have been
1281 introduced in Mars 0.9.4 when the order of calculation of the two
1282 types of pedestal in callisto got exchanged. The bug only effects
1283 the first seconds of data of each sequence.
1284
1285 - star: Taking the arrival time of Muons into account the calculation
1286 of the parameters could be made independant of the noise
1287 (pedestal rms). The dependance was due to the bias of the peak search
1288 extractor. Now only a ZA dependamcy is left which is not yet fully
1289 understood.
1290
1291 - ganymed: The sequences were still not sorted correctly in any case,
1292 because they were sorted by the full qualified path name. Now they
1293 are sorted by their sequence number.
1294
1295 - ganymed: new values for the spark-event-cut
1296
1297 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1298
1299
1300
1301 *** Version 0.9.4.1 (2005/08/18)
1302
1303 - callisto: fixed some problems with the calibration in case of
1304 inteleaved events. Therefor the final and some intermediate
1305 fits are skipped which would take place on partly filled #
1306 histograms and gave wrong results or failed completely.
1307
1308 - callisto: If the intermediate finalization of the histograms
1309 calculating the mean charge of the calibration signal fails
1310 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1311
1312 - ganymed: Fixed some bugs which caused problems in On-only mode.
1313 Still the false source plot doesn't give reasonable results.
1314
1315
1316
1317 *** Version 0.9.4 (2005/08/05)
1318
1319 - general: Fixed the ZA binning. It did not correctly fit the
1320 MC binning
1321
1322 - general: Added a class to correct for the missfocussing in
1323 April (MSrcPosCorrect)
1324
1325 - general: Random Forest energy estimator should now work properly
1326
1327 - general: MHCamera now displays the profiles in deg instead of mm
1328
1329 - general: MH::SetPalette offers a lot of new palettes
1330
1331 - general: MHillas - the case of CorrXY==0 is now handled properly
1332
1333 - general: implemented the possibility to change the line and
1334 marker style of a sky-grid drawn by MAstroCatalog
1335
1336 - general: Runs in sequences and datasets are now automatically
1337 ordered (it is assumed that the order of their filenames correctly
1338 represents the order of observations) to ensure correct reading
1339 of the subsystem data
1340
1341 - general: Runs cannot be added to a sequence twice anymore. Also
1342 Sequences cannot be added twice anymore to a dataset.
1343
1344 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1345 It gave wrong results by 1./2pi
1346
1347 - showplot: got a new option to start a root interpreter, too
1348
1349 - mars: now displays a rough estimate of Disp and the third moment
1350
1351 - mars: now displays the event time MTime if available
1352
1353 - mars: show muon parameters graphically
1354
1355 - mars: now the file to open can be given as commandline
1356 argument
1357
1358 - merpp: Added support for new arehucas version >= 200507190
1359 implementing values for three temperature sensors in the
1360 counting house (MCameraAUX) and the name of the HV settings file
1361 (MCameraHV).
1362
1363 - merrp: Also fixed some problems with wrong versions numbers stated
1364 by arehucas and implemented some fixed for old versions (<200407070)
1365
1366 - callisto: MCalibrationHiLoCam can now be printed from its context
1367 menu, eg in the TBrowser
1368
1369 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1370 - 1.39 (MExtractTimeAndChargeSpline)
1371 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1372 This is important mainly for timing studies.
1373
1374 - callisto: Changed limits in MHCalibrationChargeCalc from
1375 - -100.125 to -98 (fgChargeHiGainFirst)
1376 - 1899.875 to 1902. (fgChargeHiGainLast)
1377 - -100.25 to -99 (fgChargeLoGainFirst)
1378 - 899.75 to 901. (fgChargeLoGainLast)
1379 Introduced new limits:
1380 - fgNumLoGainBlackoutLimit: 0.05
1381 - fgLoGainBlackoutLimit: 3.5
1382 - fgLoGainPickupLimit: 3.5
1383
1384 - callisto: The handling of automatic weights for the digital filter
1385 has been improved. There are now new calibration weights special
1386 for Monte Carlo calibrations.
1387
1388 - callisto: Updated Muon scale with latest results (1% difference
1389 for most data, 5% for Mar/Apr'05)
1390
1391 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1392 was saturated and the blackout-events in the low-gain exceed the
1393 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1394 This excludes those pixels which have a saturating high-gain
1395 channel, but the low-gain switch does not switch often enough
1396 to make the distribution reliable.
1397
1398 - callisto: fix a bug counting the number of saturated events. Up to now,
1399 the number of saturated slices was counted (which is one for a not too
1400 high number), but for some (pathological) pixels, many more slices
1401 saturated and produced wrong limits.
1402
1403 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1404 + MCalibrationRelTimeCam.CheckFitResults: Yes
1405 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1406 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1407 + MCalibrationRelTimeCam.CheckOscillations: Yes
1408
1409 - callisto: introduce max. number of events for intercalibration,
1410 the rest gets skipped. Default: 4096
1411 The calibration causes too many un-reliable pixels if more
1412 than about 5000 events are treated (@500 Hz) because of the
1413 mode hopping of the VCSels. However, in the past, some
1414 calibration runs have been taken (erroneously) with more
1415 than 5000 events, especially the intensity scans where
1416 a good precision is needed.
1417
1418 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1419 photo-electrons for the spline extractor by 1-2% (correctly).
1420
1421 - callisto: The intercalibration is now done using a full f-factor
1422 method instead of a simple update. This makes things slower but
1423 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1424 changes.
1425
1426 - callisto: MPedestalY3 now uses the same extraction range as the data
1427 as calculated by MPedestalY2
1428
1429 - callisto: A check of the fraction of allowed unsuitable (10%) and
1430 unreliable (30%) pixels has been addded when the conversion is
1431 calculated from interleaved events
1432
1433 - star: fixed a bug which caused MEffectiveOnTime containers not to
1434 be written. In the worst case they were skipped almost all, in the
1435 best case they were all ok. It depends on how often the new value
1436 was assigned just with an event which was skipped later by another
1437 task
1438
1439 - star: new histograms MHPointing and MHRate
1440
1441 - star: New tab (Currents) displaying the time evolution of the mean
1442 DC currents
1443
1444 - star: New tab (MeanRms) displaying the time volution of the mean
1445 Pedestal Rms
1446
1447 - star: Output now contains MReportStarguider
1448
1449 - star: Improved muon analysis. Due to the absense of a constant
1450 for the gaus fit for arc width and the fact that the arcwidth
1451 plot was a histogram instead of a profile the resulting psf
1452 became pedestal rms dependant
1453
1454 - ganymed: added new plot (MHPhi) for wobble mode as described in
1455 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1456
1457 - ganymed: corrects now (correctly?) for the misspointing in
1458 May/April 05
1459
1460 - ganymed: Two new default templates for ganymed.rc are avilable:
1461 ganymed_onoff.rc and ganymed_wobble.rc
1462
1463 - ganymed: The first version of MFMagicCuts has been released
1464
1465 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1466
1467 - ganymed, sponde: There are two new options to determin the number
1468 of bins for the signal region (NumBinsSignal) and the number of
1469 total bins (NumBinsTotal) in the MHThetaSq histogram
1470
1471 - ganymed: optimized palettes for MHDisp
1472
1473 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1474 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1475 sqrt(2) to large
1476
1477 - ganymed: The false source plot (MHDisp) is now based on Disp
1478 and a background model determined in the first loop is
1479 subtracted
1480
1481 - ganymed: MFMagicCuts are now available in the cvs. The correct
1482 solution for the disp ambiguity problem is now calculated using
1483 the third moment. The third moment cut therefor is skipped.
1484
1485 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1486 already determined by the third moment along the major axis and
1487 so its actual sign is aligned along the major axis of the shower.
1488
1489 - ganymed: If starguider data is available it is taken into account
1490 when calculating the source position. This is especially important
1491 for wobble data at high zenith angles and culmination data.
1492
1493 - ganymed: If available the starguider data is taken into account as
1494 good as it is possible without a starguider calibration. To switch
1495 it off add
1496 MPointingDevCalc.MaxAbsDev: -1
1497 to your ganymed.rc
1498
1499 - sponde: the zenith angle distribution is now weighted instead of
1500 choosen by default. This gurantees higher statistics in the highest
1501 and lowest energy bins. To switch this behaviour off use...
1502
1503 - sponde: now automatically displays the energy threshold
1504
1505
1506
1507 *** Version 0.9.3 (2005/06/03)
1508
1509 - general: MMcEvt now derived from MMcEvtBasic which should
1510 have no influence on compatibility with older camera files
1511
1512 - general: Implemented a new option to MReadReports which allows
1513 to force reading of the first event of some trees (eg. Drive-tree)
1514 before any other tree.
1515
1516 - general: Made a fix to MPointingPosCalc which assumes that the
1517 run-type is real-data if Process is called before ReInit, such
1518 that also the very first Drive-events in a run are treated
1519 correctly.
1520
1521 - shoplot now displays the filename in the title bar of the window
1522
1523 - merpp: new options: --auto-time-start --auto-time-stop which
1524 allow to cut updating with slow-control at the start- or
1525 (previousle --auto-time only allowed: and) stop-time of
1526 the run stored in the runheader.
1527
1528 - callisto: changed default of fgFallTimeHiGain in
1529 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1530 already set as default in callisto_Dec04Jan05.rc
1531
1532 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1533 now changes the filename for new weights automatically for
1534 cosmics, MC and for different calibration colors.
1535
1536 - callisto: a problem with the order of some code cause the
1537 name of the weights file in MPedestalY2 to be ignored.
1538 Wrongly the calibration_UV weights were used instead
1539 of the cosmics weights set in callisto.rc.
1540
1541 - callisto: should allow ct1 pulser data when the color is
1542 explicitly set also for pretty new runs
1543
1544 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1545 to introduce an additional scale factor (should be around 1)
1546 to adapt for slight deviations in different extractors from
1547 the MC calibration. For MC calibrations the scale factor
1548 is fixed to 1
1549
1550 - callisto: MFCosmics should handle very high signals a bit
1551 more accurate now
1552
1553 - callisto: when calculating the mean pedestal rms for different
1554 pixel sizes or sectors also kUnsuitableEvt is now taken into
1555 account - not only kUnsuitableRun
1556
1557 - callisto: '-raw' option is now the default
1558
1559 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1560 This has the advantage that mean values in the calibration (eg
1561 arrival times) are calculated more accuratly.
1562
1563 - callisto: In the resource file callisto_Dec04Jan05.rc
1564 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1565
1566 - callisto: new Hi-/Lo-Gain intercalibration constants
1567 hilocalib_sp1.root and hilocalib_sp1_mc.root
1568
1569 - callisto: changed default for MJPedestalY2.MaxEvents
1570 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1571
1572 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1573 has changed from 9.0 to 6.0. This is necessary to exclude two very
1574 ringing pixels in September which - when kept - destroy the image
1575 cleaning around them (Markus G.)
1576
1577 - callisto: (!) The Muon analysis of all data taken so far has
1578 suggested that different extractors give slightly different
1579 absolute results after calibration, due to there different
1580 handling of the calibration- and cosmics pulse shape. Although
1581 the over all calibration seems to be a bit to pesimistic (or
1582 the MC seems to be a little bit - 3-5% - too much attenuated).
1583 There for correction factors have been introduced which correct
1584 the calibration constants by
1585 0.956937799 for Digital Filter (callisto.rc)
1586 and
1587 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1588 calibration. The main advantage is, that both data types can
1589 be easily analysed together and compared to the same MC sample.
1590 The factors are choosen such, that the reference is now a
1591 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1592
1593 - star: fixed a bug which caused the first bin of the histograms
1594 vs time to disapear in PostProcess. This gave wrong results
1595 on the screen. The output and all following programs not
1596 directly accessing the histograms haven't been affected
1597
1598 - star, ganymed: Made sure that always the first Drive-tree event
1599 is read and Processed before the first data event was read.
1600
1601 - ganymed: implemented the possibility to replace the standard
1602 false source plot with a different one. For example: If
1603 you want to use a Disp based FS plot use the resource:
1604 NameHistFS: MHDisp
1605 For details about the requirements of these plots look
1606 at the corresponding classes
1607
1608 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1609 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1610 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1611 case MAlphaFitter is setup correctly. For On-Only optimization
1612 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1613 RunOn() instead of Run(). For energy estimation MJOptimize
1614 has been replaced by MJOptimizeEnergy
1615
1616 - sponde: The input MC spectrum can now be weighted to fake a
1617 different spectrum. This is done via MMcSpectrumWeight. For
1618 more details see the class description and sponde.rc
1619
1620 - sponde: The paremeter comparsion plots are not scaled by
1621 their entries anymore. Instead the MC plot is scaled by using
1622 the result spectrum of the analysis. If the input MC spectrum
1623 and the result spectrum has different slopes the absolut
1624 normalization is normally wrong.
1625
1626
1627
1628 *** Version 0.9.2 (2005/05/20)
1629
1630 - general: Changed the default paths for calibrated data and image
1631 files. (The implemented access to these files doesn't yet exist)
1632
1633 - general: support for MRunIter has been removed from the job classes
1634 (use the setter functions of MSeqeunce instead)
1635
1636 - general: ProcessFile has been renamed to Process in all job classes,
1637 because ProcessFile is missleading
1638
1639 - general: The storage of the palette in MHCamera is now possible
1640
1641 - general: new bits describing unsuitable and unreliable pixels have
1642 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1643 kDeadPedestalRms, kFluctuatingArrivalTimes
1644
1645 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1646 versions newer than V200404070
1647
1648 - general: support for cc file versions newer than V200504130. Added
1649 support for active loads (MCameraActiveLoad) and central pixel
1650 (MCameraCentralPixel)
1651
1652 - general: added new histograms for image parameters versus size
1653 (MHVsSize)
1654
1655 - general: The eventloop now automatically calls PrintStatistics
1656
1657 - Status Display: Improved support for printing:
1658 + A default can now be set in .rootrc (for more details see
1659 MStatusDisplay::PrintPS)
1660 + A print dialog is opened so that printer and command line
1661 can be canged
1662
1663 - showlog: improved such that it handles different verbosity levels
1664 more accurate now. This mean you can suppress output when
1665 using showlog.
1666
1667 - showplot: improved
1668 + The new graphics formats have been implemented
1669 (pdf, svg, png, jpg and xpm)
1670 + Implemented an interface for printing. Because you can change
1671 the printing command from the command line you can use all
1672 the nice postscript tool. To print a booklet for example call:
1673 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1674 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1675 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1676
1677 - callisto: fixed a bug in the recognition of the calibration bit
1678 pattern. Concerns only intensity calibration. (The strength of the
1679 intensity has been updated in some cases)
1680
1681 - callisto: add a filter against PIN Diode events when running over
1682 calibration runs since some of the recent calibration runs have
1683 been taken with Pin Diode.
1684
1685 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1686 39943, 44833 in the calibration (MCalibColorSet)
1687
1688 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1689 been set to 1e-18 in callisto_Dec04_Jan05.rc
1690
1691 - callisto: in callisto_Dec04Jan05.rc: set value for
1692 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1693 statistics for the calculation of the mean pulse time
1694 of the cosmisc
1695
1696 - callisto: the charge limit in the calibration has been raised
1697 from 2.5 to 4.5
1698
1699 - callisto: new setup read from callisto.rc
1700 + MCalibCalcFromPast.fNumEventsDump
1701 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1702 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1703
1704 - callisto: MExtractTimeAndChargeSpline extractor:
1705 + The integration ranges were shifted by 0.2 FADC slices to the right.
1706 + unreliable handling of floating point values caused different
1707 results on different platform or with different compiler options:
1708 The new algorithm is numerically exact and more accurate because
1709 it doesn't calculate the integration position by multiple times
1710 adding the step-size (which results in numerical uncertanties
1711 exspecially if multiplied with large numbers)
1712 + A lot of fixes have been introduced which effects integrating the
1713 spline at the edges of the valid range. In this case any memory
1714 was randomly accessed. This behaviour can be tested replacing
1715 all MArrayF by TArrayF which perform a range check (but of course
1716 they are a lot slower)
1717 ! No result obtained with the Spline before can be trusted! Due to
1718 random memory access it might by completely random!
1719
1720 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1721 + extraction range in the high gain to 4.
1722 + weights file to cosmics_weights46.dat
1723
1724 - callisto:
1725 + introduce the check for fluctuating arrival times.
1726 + set charge limit to from 2.5 to 4.5
1727 + introduce asymmetric exclusion due to "deviating number of phes":
1728 Default: -9.0 +4.5
1729 + make deviating number of phes unsuitable (see David's findings).
1730
1731 - callisto: fixed the display of unsuitable pixels. The old change
1732 to a real profile in MHCamera broke it.
1733
1734 - callisto: The cosmics filter is used in MJCalibration now
1735 independant of the pulser color (formaly it was used only for
1736 CT1-pulser data). The threshold of number of max empty pixels
1737 has been raised from 2% to 5% in MJCalibration. The maximum
1738 fraction of rejected event is 50% otherwise the calibration has
1739 failed. The filter now ignores unsuitable pixels.
1740 Setup the filter from callisto.rc using "ContCosmics"
1741 (see MFCosmics::ReadEnv)
1742
1743 - callisto: changed default for fgOffsetFromLogain back
1744 from -2.8 to -1.8 in digital filter.
1745
1746 - callisto: for the common extractors
1747 + MExtractFixedWindow
1748 * MExtractTimeAndChargeSlidingWindow
1749 * MExtractTimeAndChargeSpline
1750 * MExtractTimeAndChargeDigitalFilter
1751 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1752 and fResolutionPerPheLoGain
1753
1754 - callisto: Updated the hi-/lo-gain intercalibration constants
1755 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1756 hilocalib_df6.root
1757
1758 - callisto: The default lo-gain extraction window for the
1759 MExtractTimeAndChargeSlidingWindow extractor has been increased
1760 from 6 to 8 to take the stretch of the pusle into account
1761
1762 - callisto (!!!): fixed an important bug in the setting of the
1763 incoming pedestal pointer to the signal extractor extracting
1764 pedestals. This bug caused the pedestals not to be subtracted
1765 correctly in the calibration afterwards. The effect was about 10%
1766 too high conversion factors for the digital filter and the spline
1767 and more than 40% for the sliding window.
1768 The bug existed since end of February! (Markus G.)
1769
1770 - star: added muon support to star. A new tab "MHMuonPar" is
1771 displayed. The lower right plot is an estimate of the point spread
1772 function. A reference value is displayed. To get the real PSF
1773 you must compare with MC. The setup for the muon analysis
1774 is done in star.rc. More informations can be found in
1775 MHSingleMuon and MHCalibParCalc
1776
1777 - star: The weather data is now displayed in star
1778
1779 - star: MEventRateCalc handles the calculation of the event rate more
1780 accurate now in case of the start of a new run inside a sequence
1781
1782 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1783 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1784 changed only minimally
1785
1786 - ganymed: (MJCut and MJOptimize) now displayes the number of
1787 excess events versus size. The energy estimation is done in
1788 MJSpectrum (sponde)
1789
1790 - ganymed: got support for using other variables than Alpha, eg. Theta.
1791 Therefor you need a class deriving from MHAlpha which supports
1792 this variable (one is already existing: MHTheta, which is now the
1793 default in ganymed). It is setup through ganymed.rc
1794
1795 - added a full featured spectrum program (sponde) which reads
1796 ganymed output and monte carlos and compiles a spectrum
1797
1798
1799
1800 *** Version 0.9.1 (2005/04/14)
1801
1802 - Fix bug on the arrival time reconstruction when using Digital
1803 Filter (in some marginal cases (10%) times were reconstructed shifted
1804 by 0.2 slices)
1805
1806 - all executables now return 2 where in previous versions -1 has
1807 been returned (gave problems with shell-scripts)
1808
1809 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1810 also done with a intercalibration input file
1811
1812 - a bug in the time fine adjustment of the digital filter has been fixed
1813
1814 - a lot of small fixes to calling TPad::Divide with a margin==0
1815
1816 - MStatusDisplay now shows the memory usage
1817
1818 - added a memory leak statistic after the eventloop
1819
1820 - MHadronness replaced by MParameterD
1821
1822 - MEnergyEst replaced by MParameterD
1823
1824 - wobble mode can now be switched on from the data-set
1825
1826 - switched on bad pixel detection for a pedestal level
1827 which is more than 5 times the variance
1828
1829 - Fixed default paths to be correct for the new data center
1830
1831 - Fixed handling of drive data. The pointing position in now
1832 copied to MPointingPos inside star for real and MC events
1833
1834 - made sure, that the sequences in a dataset are sorted by
1835 their number to ensure the correct synchronization
1836
1837 - added all resource files necessary to handle spline extraction
1838 of signal for the late 2004 and the early 2005 data
1839
1840 - update the reference lines for the december data
1841
1842 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1843 This is important for the Dec. and Jan. data where the calibration
1844 pulse position changes much.
1845
1846 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1847 filter. This corrects only an defective extraction of the MC at
1848 low-gain signals lower than 90 phes.
1849
1850 - fixed some slowdown in calibrating data with interleaved events from
1851 Jan and Dec. As a workaround made the pretty palette the default.
1852 The inverse Deep Blue Sea has a bug which slows down long calibration
1853 runs a lot.
1854
1855 - implemented new values from new starguider report as defined
1856 in TDAS00-07 V7.1 (eg SkyBrighness)
1857
1858 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1859 in starguider report (If you merpp the same reports with this version
1860 you'll get the correct units (arcmin) but a different result
1861 than with old versions (wrong units))
1862
1863 - Now the status display can also write PNG, JPEG and XPM (other file
1864 formats are still unsupported by root)
1865
1866 - added a lot of scripts and macros in directory datacenter used
1867 for automatic processing
1868
1869
1870
1871 *** Version 0.9 (2005/03/23)
1872
1873 - Calibration is now done autmatically into photo-electrons like
1874 decided by the Collaboration Board
1875
1876 - Reference lines in the display can be read from resource file
1877
1878 - Interlaced calibration events can be handled by callisto
1879
1880 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1881 and applied in callisto.
1882
1883 - class MJCalibTest can be called by callisto
1884
1885 - callisto can now run with three data types: rawdata, rootdata, MC
1886
1887 - added two classes mreport/MReportStarguider.cc and
1888 mreport/MReportStarguider.h for implementing starguider-data
1889
1890 - the output of merpp-update now contains starguider information:
1891 MReportStarguider and MTimeStarguider
1892
1893 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1894 values were lower than they should. This was more visible for high
1895 energy (Size) events.
1896
1897 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1898
1899 - added a new loop to callisto to support the correct extraction of
1900 the pedestal and pedestal rms through the signal extractor
1901
1902 - added class to perform fourier tranformation of a hexagonal structure
1903 (MHexagonalFT)
1904
1905 - added class to perform fourier tranformation of a hexagonal structure
1906 in a tasklist (MHexagonalFTCalc) example: hft.C
1907
1908 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1909 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1910 small pixels, example: extendcam.C
1911
1912 - added possibility to write data to memory (TTree) using MWriteRootFile
1913
1914 - added possibility to read a TTree stored only in memory by MReadTree
1915
1916 - new classes to deal with the interleaved calibration events:
1917 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1918
1919 - implemented filters to callisto to skip calibration events
1920
1921 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1922 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1923 the slices by statistics
1924 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1925 signal extractor without randomization
1926 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1927 with the signal extractor with randomization (extraction window is
1928 randomly fixed)
1929 The three kind of pedestal is not yet implemented (for speed reasons) as
1930 long as nobody really needs it:
1931 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1932 extracted with the signal extractor with randomization
1933
1934 - callisto now finds the pulse position in the data automatically
1935
1936 - implemented data reduction in calibrated data by reducing the precision
1937 of the stored floating point values (pedestal, rms and signal) to
1938 roughly 0.5%
1939
1940 - fixed showplot to make file format conversion (eg. converting a
1941 status display stored in a root file into a postscript file) in
1942 batch mode possible:
1943 showplot -b --save-as-ps[=outfile.ps] infile.root
1944
1945 - Allow class names as part of filter rules, eg
1946 (MFSupercuts) && (MHillas.fSize>100)
1947
1948 - fixed a lot of stuff to allow all programs to process MonteCarlo
1949 camera files.
1950
1951 - enhanced possibility to debug reading of resource file
1952
1953 - MDataChain should handle priorities of operator more
1954 accurate now
1955
1956 - completely revised the container in which the signal is stored
1957 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1958 * the new implementation is faster and
1959 * needs less storage space
1960
1961 - FIRST version which can process Monte Carlos through the
1962 whole chain of programs (callisto, star, etc)
1963
1964 - implemented new image parameters for the border length of
1965 the shower image (MNewImagePar2)
1966
1967 - implemented wobble-mode in ganymed
1968
1969 - new class (MJOptimize) taking care of all optimization processes
1970
1971
1972
1973 *** Version 0.8.6 (2004/10/05)
1974
1975 - New combined signal and time extractor
1976 MExtractTimeAndChargeDigitalFilter
1977
1978 - The Report for the trigger section in the CC run summary has been
1979 updated, and now the IPRs (Individual Pixel Rates) are available.
1980
1981 - new macros for database interaction: filldotrun.C, filldotrbk.C
1982
1983 - added new program which can convert colored output which was redirected
1984 into a file back into colored text (for example to display it with
1985 more): showlog
1986
1987 - added new program to display an MStatusArray of plots (stored with
1988 MStatusDisplay) from a file: showplot
1989
1990 - Added support for Sequences (MSequence). Sequences are blocks of run
1991 files containing the same calibration and belonging to the same
1992 source
1993
1994 - Added a new task (MTaskEnv) which can be used in setup files to switch
1995 between different tasks (for example to choose a signal extractor)
1996
1997 - Implemented automatic file splitting in MWriteRootFile
1998
1999 - After image cleaning an island index is assigned to all used pixels.
2000 The index corresponds to the order of the islands in size.
2001
2002 - added a cleaning which takes signal height _and_ arrival time into
2003 account: probability cleaning (for more details see MImgCleanStd)
2004
2005 - added a cleaning which takes takes the absolute number of photons
2006 times the area ratio as cleaning level
2007 (for more details see MImgCleanStd)
2008
2009 - Changed calculation of image parameters such, that it can be done
2010 for all used pixels or the pixels with a defined island index only
2011
2012 - implemented new image parameters displaying the number of islands,
2013 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2014
2015 - event display in executable changed to support also calibrated files
2016 (done with MJCalibrateSignal)
2017
2018 - added program doing the calibration and the signal extraction
2019 and signal calibration: callisto Most part of the setup is done
2020 by a resource file: callisto.rc
2021
2022 - implemented support for pixels with negative IDs (Raw file format
2023 version 4)
2024
2025 - implemented an new option in merpp (--auto-time) to get the time
2026 range for cc and/or caco data from the run header of the raw data
2027
2028 - New star-program (star and MJStar). Taking calibrated data from
2029 callisto/MJCalibrateSignal as input. The setup is done through
2030 a resource file: star.rc
2031
2032 - Added possibility to setup the eventloop in the mars-executable
2033 Camera Display by a resource file: mars.rc
2034
2035 - The the mars-executable Camera Display can now also read
2036 calibrated data files written by callisto/MJCalibrateSignal
2037
2038 - Added a new class which can calculate the source position in
2039 the camera from a pointing model known to be correct and
2040 the pointing model used for observations (MSrcPosFromModel)
2041
2042 - added a new version of the class calculating the effective on-time
2043 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2044 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2045 MHTimeDiffTheta.
2046
2047 - added the possibility to count how often a signal is above (or
2048 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2049 can replace MHTriggerLvl0)
2050
2051 - added ore convinient ways to set the axis-titles of your histograms
2052 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2053 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2054
2055
2056
2057 *** Version 0.8.5 (2004/08/06)
2058
2059 - new Signal Extractors: MExtractFixedWindowSpline
2060 and MExtractAmplitudeSpline
2061
2062 - implementes interleave in merpp to be able to merpp parts of a file
2063
2064 - implemented force-functionality to merpp
2065
2066 - star display to display star catalogs (MAstroCatalog)
2067
2068 - star display to 'mirror' stars to the camera (MAstroCamera)
2069
2070 - implemented a new cleaning option which allows cleaning scaled with
2071 the real ratio of the rms depending on the pixel size, not only the
2072 square root of the pixelsize (MImgCleanStd, MCameraData)
2073
2074 - removed obsolete MBlind* classes
2075
2076 - Signal extractor taking the AB flag into account implemented (this makes
2077 an odd number of slices for signal extraction possible
2078 (MExtractSignalABcorr)
2079
2080 - implemented a class extracting the pedestal from the raw-data (events)
2081 itself using empty lo-gain (MpedCalcFromLoGain)
2082
2083 - Added mean values to MPedPhotCam
2084
2085 - Added Makefile for Darwin (this OS is NOT officially supported!)
2086
2087
2088
2089 *** Version 0.8.4 (2004/04/19)
2090
2091 - new fast arrival time extractor using cubic splines:
2092 MExtractTimeFastSpline
2093
2094 - implementes multi-argument support in MDataChain
2095 ("pow(a, b)")
2096
2097 - implemented double reference support in MDataChain
2098 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2099
2100 - added support in MF for expressiond like
2101 "MHillas.fWidth<2*<MHillas.fLength"
2102
2103 - MDataChain is now able to support variables like [0], [1], ...
2104 which can be used in fit functions as parameters. The interface
2105 is implemented through the new virtual function
2106 MParContainer::SetVariables
2107
2108 - added new class MArrivalTimeCam/MArrivalTimePix:
2109 Storage containers to hold the ArrivalTime of the camera/pixel
2110
2111 - added new classes for the calibration of relative arrival times:
2112 MCalibrationRelTimePix and MCalibrationRelTimeCam
2113
2114 - added new classes to extract the signal of the blind pixel and the
2115 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2116
2117 - added new classes for the bad-pixels treatment (MBadPixels*)
2118 which are more powerfull than the old ones (MBlindPixel*)
2119 and will replace them.
2120
2121 - added filter against cosmics: MFCosmics
2122
2123 - added new class MArrivalTimeCalc2:
2124 Calculates the arrival time as the signal weighted mean of the time
2125 slices in the maximum window
2126
2127 - added a new macro call pointspreadfucntion.C that fits with a 2D
2128 gaussian the DC spot for an star. It gives you the RMS of
2129 the PSF and the center of the star, very useful for misspointing
2130 studies.
2131
2132 - added support for multi-telescope camera files. Added classes
2133 MStereoCalc and MStereoPar, classes to calculate and store shower
2134 parameters calculated from the data of two telescopes, for the MC
2135 studies regarding the MAGIC clone.
2136
2137 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2138 MC data calibrated in photons instead of ADC counts.
2139
2140 - added three macros to show the calibration and analysis chain of
2141 MC data. The macro starmc.C does both calibration and analysis, producing
2142 an output containing Hillas parameters for each event. The macro
2143 mccalibrate.C does just the calibration and writes out a file containing
2144 pixel information in photons instead of FADC data. The macro starmc2.C
2145 reads in such a file and produces an output with Hillas parameters.
2146
2147 - added MPedPhotCalc to compute pedestals in units of photons, see
2148 macro pedphotcalc.C
2149
2150 - added all class to perform the calibration, see macro calibration.C
2151
2152 - added class MFFT to perform Fast Fourier Transforms
2153
2154 - added class MSimulatedAnnealing to perform simulated annealing
2155 minimizations
2156
2157 - added new macro bootcampstandardanalysis.C which holds the skeleton
2158 of the analysis chain discussed in the december bootcamp.
2159
2160 - added support for DAQ raw data file format V2
2161
2162 - implemented an arbitrary time stamp for the events from raw-data
2163 files with file version<3. It is calculated from the run number,
2164 the date of start and the FADC clock tick from the first module
2165
2166 - implemented the correct decoding of the event time-stamp
2167 coming from the DAQ for raw-data files with file-version>2
2168
2169 - added a new classes storing the pedestals in units of photons:
2170 MPedPhotPix, MPedPhotCam
2171
2172 - added support for DC current files from the camera control
2173
2174 - added support for start- and stop-time when merpping report files
2175
2176 - added MReportCC storing the weather data from the CC-REPORT
2177
2178 - added class to fill trainings and test matrices (MTFillMatrix)
2179
2180 - added a filter performing a software trigger (MFSoftwareTrigger)
2181
2182 - Added classes to perform parts of the standard analysis (Jobs):
2183 + MJPedestals
2184 + MJCalibration
2185 + MJExtractSignal
2186 Note: All of them are preliminary!
2187
2188 - Added Iterator to iterate over files giving only the run-number
2189
2190 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2191 the evolution of a sector vs time
2192
2193
2194
2195 *** Version 0.8.3 (2003/12/05)
2196
2197 - adapted Random Forest classes to allow the use with MC
2198 multi-telescope files which can be produced with the coming
2199 camera version 0.7.
2200
2201 - added classes to read and interprete central control report files
2202 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2203
2204 - enhanced merpp (the executable) to support .raw and .rep files.
2205
2206 - added classes for light calibration (MCalibration* and
2207 MHCalibration*) by Markus Gaug. Further work has to be and will
2208 be done soon.
2209
2210 - Added a preliminary 'synchronizer' (MReadReports) which will
2211 replace MReadMarsFile as soon as it is finished.
2212
2213 - Added a tutorial macro demonstrating how report files are merpped
2214 and how they can be read from the root file in the correct order
2215 of time (readrep.C)
2216
2217 - Added a generalized histogram (similar to MH3) called MVsTime
2218 which allows to plot variables (or rules - MDataChain - of
2219 variables) vs time. For an example have a look at tempvstime.C.
2220
2221 - Changed the name of the event trees:
2222 + Events --> Events
2223 + PedEvents --> Pedestals
2224 + CalEvents --> Calibration
2225
2226 - changed name of MTime in the event trees from MRawEvtTime to MTime
2227
2228 - added displaying the sector indices to the mars event display
2229
2230 - Magic Online Analysis (MOnA) implemented in a first version
2231 (see mona.cc, MOnlineDump and MOnlineDisplay)
2232
2233 - added classes to calculate event rate
2234 (preliminary: MEventRateCalc, MEventRate)
2235
2236 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2237
2238 - added classes dealing with the telescope pointing position (MPointing*)
2239
2240 - implemented the 'final' Mars time stamp based on some experiences with
2241 the new 'Synchonizer'
2242
2243
2244
2245 *** Version 0.8.2 (2003/11/10)
2246
2247 - accelerated standard analysis by a factor of 6-8 ...
2248 + doing precalculations in MGeomCam for the pixel area ratio
2249 + creating a look up table for the single pixels in MCerPhotEvt
2250
2251 - added task to calculates weights in case you want to 'change'
2252 the energy spectrum of a monte carlo file
2253 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2254
2255 - added a new executable star which implements the
2256 star.C macro as precompiled executable. Currently a flexible
2257 setup is not possible, but a 'input card' setup will follow.
2258
2259 - Starting to implement Multi-Telescope-Support based on the
2260 upcomming camera version 0.7. The base for a general support
2261 is implemented and the star-functionality is proven to work.
2262
2263 - Replaced Event-Display in and Camera-Display in the Mars GUI
2264 executable by a more convinient display base on MStatusDisplay.
2265
2266 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2267
2268
2269
2270 *** Version 0.8.1 (2003/10/20)
2271
2272 - added signal subtraction for pure on data by means of fitting
2273 the background in the off region or by performing a combined
2274 signal/background fit. Provides necessary histograms for
2275 obtaining energy spectra and a light curve.
2276
2277 - added classes to perform and study the selection of the
2278 2nd Level Trigger on MC data (example in triglvl2.C macro)
2279
2280 - added pedestal calculation
2281
2282 - implemented "democratic cleaning" (tail cut value proportional
2283 to pixel area) according to Wolfgang's suggestion.
2284
2285 - added Sigmabar treatment (calculation and basic histogramming)
2286
2287 - added basic routines to apply padding
2288
2289 - added first implementation of MARS-based source visibility plotter
2290 (needs to be linked against slalib, preliminary version)
2291
2292 - enhanced functionality of data chains: random numbers, conversion
2293 functions and access to MHMatrix objects
2294
2295 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2296 numbers under certain circumstances (runs with 0 events included)
2297
2298 - fixed a bug in the general filter MF (didn't work on some systems
2299 at all)
2300
2301 - fixed a bug in chaining files, which caused the analysis to crash or
2302 ignore files
2303
2304 - implemented more geometry classes describing the parameters used
2305 to simulate the PMT camera
2306
2307 - added new Monte Carlo classes containing the setup of the different
2308 programs in the MC chain.
2309
2310 - added a (preliminary) general task to evaluate chi-square of a given
2311 parameter in an eventloop.
2312
2313 - first implementation of a container describing the observatory
2314 location (Long, Lat, etc)
2315
2316 - added Random Forest - method for g/h-separation
2317
2318 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2319 (this means, that it is compiling, but not yet fully tested)
2320
2321 - added a new status display which can show the present status
2322 of histograms while an eventloop is running (MStatusDisplay,
2323 an example can be found at status.C)
2324
2325 - reorganized directories:
2326 classes describing the image --> mimage
2327 classes containing Monte Carlo Histograms --> mhistmc
2328 classes for Random Forest method --> mranforest
2329
2330 - added (event-)weights to fill histograms
2331
2332 - colors in logging output to screen
2333
2334 - changes to the Image Parameter declaration:
2335 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2336 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2337 + MHillasExt now derives from MParContainer instead of MHillas
2338 --> Files written with the old definition are more or less unreadable
2339
2340 - reading of reflector files
2341
2342 - display data from reflector files in the camera
2343
2344 - implemented currents (and display them in the camera)
2345
2346 - logarithmic scale in camera
2347
2348 - added class to iterate through directory contents (MDirIter)
2349
2350
2351
2352 *** Version 0.8 (2002/11/18)
2353
2354 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2355
2356 - corrected 48(!) wrong entries in the Next Neighbor table of the
2357 Magic Camera (all in the inner part of the outer ring, mostly
2358 missing a single NN)
2359
2360 - Fixed a bug in the table describing the Next Neighbours of the
2361 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2362 have any neighbour)
2363
2364 - changed trigrate.C: now it calculates the pure NSB triggers from
2365 a camera file (generated with no showers), so there is no need
2366 to introduce them by hand in the BgR array (for more details
2367 please ask Abelardo)
2368
2369 - added MHHadronness (and MHadronness) as a general facility to evaluate
2370 the quality of a gamma-hadron seperation method
2371
2372 - changed MWriteAsciiFile to accept rules (MDataChain)
2373
2374 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2375 must be replaced by calles to MWriteAsciiFile::AddColumn and
2376 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2377 changed.
2378
2379 - Implemented generalized event-matrices (one row per event)
2380 (MHMatrix)
2381
2382 - implemented the one dimensional composite probabilities
2383 (MHCompProb, MCompProbCalc, comprob.C)
2384
2385 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2386 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2387
2388 - Added a camera display displaying the pixel numbers to the
2389 event display gui.
2390
2391 - Added Monte Carlo Informations to event display gui
2392
2393 - Changed the camera display to display the pixel numbering
2394
2395 - Added three buttons to the camera display to change the palette
2396
2397 - Added the number of used and core pixels after image cleaning
2398 to MHillas
2399
2400 - Changed the algorithm used in MHillas according to TDAS 02-03
2401
2402 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2403
2404 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2405
2406 - Added fCosDeltaAlpha to MHillasSrc
2407
2408 - The numbers of photons used to calculate fConc and fConc1 in
2409 MHillasExt are now scaled with the pixel size, so that one get
2410 a four times smaller value for the bigger pixels in the outer ring.
2411
2412 - added new task to smooth the camera contents (MCameraSmooth)
2413
2414 - added possibility to use interpolated pixel values for blind pixels
2415 instead of removing it completely from the analysis
2416
2417 - Implemented the possibility to save the whole eventloop with
2418 its setup to a file. This information can be read and from
2419 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2420 and MEvtLoop::MakeMacro. If you find something not working, please
2421 report - this stuff is still in a beta phase.
2422
2423 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2424 file having crab starfield, but also for all following files - fixed
2425
2426 - MTaskList::PrintStatistics can now be instructud to print also the
2427 title, too: use PrintStatistics(0, kTRUE)
2428
2429 - Changed the image cleaning so that pixels with to many 'used'
2430 neighbors are left used (to get rid of 'holes' in events)
2431
2432 - Introduced more output to the camera displays
2433
2434 - Added an array of histograms (eg one hist per run), MHArray
2435
2436 - Added a _preliminary_ version of the reader for CT1 PreProc files
2437 (MCT1ReadPreProc)
2438
2439 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2440 (thanks to Raquel)
2441
2442 - added the first energy estimator (MEnergyEstParam, estimate.C,
2443 estfit.C) using a parametrization
2444
2445 - Added some new Monte Carlo paremeter containers used to store
2446 setup information from the MC chain (MMcConfigRunHeader,
2447 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2448
2449
2450
2451 *** Version 0.7 (2002/04/30)
2452
2453 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2454 the pedestal mean value was saved incorrectly. For files from
2455 this versions we substract 0.5 from the pedestal mean.
2456 WARNING: This may effect your results, so don't wonder...
2457
2458 - First implementation of an algorithm using only triggered events
2459 for the collection area calculation
2460
2461 - Ascii Output can now also be used for parameter containers which
2462 doesn't overload MParCointainer::AsciiWrite
2463
2464 - The Ascii Output is now also capable of writing single data members
2465 of one container
2466
2467 - You are now able to change the order of the values written to the
2468 ascii file
2469
2470 - You can now specify a conversion factor for each data member written
2471 to an ascii file. This may be usefull to change the units of the
2472 data member (eg. degrees instead of millimeters in case of the
2473 hillas parameters)
2474
2475 - Replaced old MHillas by a new structure which allows you to extend
2476 the parameters stored in MHillas very easily:
2477 see MHillas and MHillasExt
2478
2479 - Added classes to handle source dependancy of image parameters:
2480 see MHillasSrc
2481
2482 - Added container (MBinning) to have a standard input for the binning
2483 in different histograms (eg. the Energy bins should be the same in
2484 all histograms)
2485
2486 - Changed Hillas histograms from mm to deg
2487
2488 - Added the flexible binning to the hillas histograms
2489
2490 - Added a filter for the alpha parameter (MFAlpha)
2491
2492 - It is now possible to write single data members of a class object to
2493 an output stream instead of the whole container only
2494
2495 - Added a generalized filter for a data member:
2496 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2497
2498 - Added a generalized Filter parser for more difficult filter rules
2499 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2500
2501 - Added new Monte Carlo histograms:
2502 MHMcEnergyImpact and MHMcEfficiency
2503
2504 - Added many new histograms needed for the flux calculation.
2505
2506 - Added a generalized histograms which can fill and show up to three
2507 data members in either a one-, two- or three-dimensional histogram, eg:
2508 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2509
2510 - Added:
2511 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2512 * calculation of <Theta> as a function of time (MHThetabarTime)
2513 they are needed in the flux calculation in
2514 order to select for a given bin in Theta (or time) the appropriate
2515 effective collection area, which is assumed to be given as a function
2516 of Theta and the true energy
2517
2518 - Added calculation of the migration matrix in the energy
2519 (MHMcEnergyMigration):
2520 the migration matrix describes the migration from the true (E_true)
2521 to the estimated energy (E_est); it is needed to determine the
2522 distribution of E_true from the measured distribution of E_est
2523 by unfolding
2524
2525 - changed the color palette in the camera display to DeapSea.
2526
2527
2528
2529 *** Version 0.6 (2002/01/15)
2530
2531 - Introduce the option of disable pixels (MBlindPixels and
2532 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2533 able to deal with Star Field NSB.
2534
2535 - Fixed a bug in the pedestals substraction
2536
2537 - Introduced verbosity levels
2538
2539 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2540
2541 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2542 work correctly (thanks to Abelardo)
2543
2544 - Introduced correct treatment of the diffuse Night Sky Background
2545 and NSB (MMcPedestalNSB)
2546
2547 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2548
2549 - Introduced MMcRunHeaders which contains monte carlo run informations
2550
2551 - Added a 'Print'-Task (MPrint) which calls the Print function
2552 of a parameter container for each event
2553
2554 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2555
2556 - changes to be more efficient with root 3.02/06
2557
2558 - root 3.02/06 fixes:
2559 + the memory leak when reading MRawEvtData
2560 + loosing more time than necessary to update the progress bar
2561
2562 - MWriteAsciiFile is now capable of writing more than one container
2563 in a line. For example: To be able to write Monte Carlo and
2564 Hillas values (energy and alpha) in one line.
2565
2566
2567
2568 *** Version 0.5 (2001/11/06)
2569
2570 - Added new GUI functionality (Analysis)
2571
2572 - Added a camera display to be able to display events in the camera
2573 together with the calculated hillas ellipse
2574
2575 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2576 object at any state of the analysis, so that the output are several
2577 states
2578
2579 - Fixed a bug in the collection area error calculation
2580 (Thanks to Ciro and Abelardo)
2581
2582 - Fixed a bug which causes merpp to crash in some environments
2583
2584 - Implemented auto enabling scheme for Branches to speed up reading
2585 a lot (see MReadTree and MTask)
2586
2587 - Fixed a bug in the Histogram classes which caused histograms to
2588 be written to a file by MWriteRootFile without request
2589
2590 - changed the object I/O from the old stylish root I/O to the new
2591 'auto evolution scheme' This was done only for classes which are not
2592 yet used in Monte Carlo files, so that these files are still readable.
2593
2594 - Added support for a progress bar in MEvtLoop and MReadTree
2595 (see the Analysis Window in Mars for an example)
2596
2597 - Fixed a bug in the package creation which disturbed the conversion
2598 between a mars version unpacked from a tar file and the repository.
2599
2600 - Changed the code to writer merpped (converted into root format)
2601 raw files, to get faster (around 10%)
2602
2603
2604
2605 *** Version 0.4 (2001/09/20)
2606
2607 - This release is made to compile on a root version >= 3.00
2608
2609 - Fixed a bug which causes MReadTree to read the first file only
2610
2611 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2612
2613 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2614
2615 - Added a task to write several container to a root file (MWriteRootFile)
2616
2617 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2618
2619 - Added calculation of the collection area (MMcCollectionAreaCalc)
2620
2621 - fixed some bugs in the Hillas calculation
2622
2623 - added filters to be able to control the task execution dependent on
2624 a parameter (for example: the number of level 1 triggers in a MC-file)
2625
2626
2627
2628 *** Version 0.3 (2001/04/23)
2629
2630 - Many demo macros added
2631
2632 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2633
2634 - Hillas Calculation added
2635
2636 - Standard image cleaning available
2637
2638 - MReadTree is now able to handle more than one file
2639 (Remark: of the same structure)
2640
2641 - Now we are able to display events in a first version of the
2642 Camera event display. To do this we must run the macro
2643 "macros/readCT1.C" to read data from CT1.
2644
2645
2646
2647 *** Version 0.2 (2001/01/24)
2648
2649 - First Implementation of a Gui to read the raw data. Start the
2650 gui with the command mars.
2651
2652
2653
2654 *** Version 0.1 (2000/12/20)
2655
2656 - First official release 0.1
2657
2658 - Changes:
2659
2660 + changed calling style of MRawPixelIterator from do...while to
2661 while-loop
Note: See TracBrowser for help on using the repository browser.