source: trunk/MagicSoft/Mars/NEWS@ 8813

Last change on this file since 8813 was 8788, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 112.8 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general
6
7 * fixed GroupBy options in plot*.C macros
8
9 * only display KVA points (not the Tuorla points) in plotoptical.C
10
11 * all programs now allow to add resources to the ones from the resource
12 file or overwrite them from the command line. This can be done like this
13 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
14 if something seems to be wrong you can debug what the program is doing
15 using the option --debug-env=3
16
17 * increased the diversity of debug levels. That also means that with -v3
18 you get now less output, i.e. only the output which is important for
19 an analysis. To get more output which helps for debugging try 4, 5 and 6.
20
21 * fixed a problem in the task synchronizing the reading of the reports
22 and the data stream. The effect was that in some circumstances the last
23 events of some trees could have been skipped. Since this is only a
24 very tiny part of the data no severe effect to your analysis results
25 is expected.
26
27 * Dataset file now allow to include the sequence file directly within
28 the dataset file and also allow to exclude single runs from the dataset.
29 (for more details see Class reference of MDataSet)
30
31 * Sequence files now allow for excluding runs from the analysis
32 (for more details see Class reference of MSequence)
33
34 * added code to process the sum-trigger flag
35
36 ;callisto
37
38 * in the pedestal processing now at least 50 processed events are
39 required for succeeding.
40
41 * the signal and calib files now contain also the sequence information
42
43 * the two MPedestalCam in the calib file now have proper names
44 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
45
46 * Both pedestal cams now conatain the number of events processed
47
48 ;star
49
50 * the star file now contains also the sequence information
51
52 ;ganymed/sponde
53
54 * Now data points are even shown correctly if they have error bars larger
55 than one sigma. Points with null or negative significances are omitted.
56
57 ;sponde
58
59 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
60
61
62
63 *** Version 2.0 (2007/09/03)
64
65 - database: the position used for the pulse pos check was missing
66 in the callisto output and could thus not be filled into the DB.
67 Also the old values seemed not exactly the PulsePos used for
68 teh check.
69
70 - general: Resource file now allow an Include-Resource, i.e. you can
71 read a resource file with default settings, include it in your
72 resource file and overwrite the settings in your file. More than
73 one include file is allowed. Inclusions can be iterative.
74 Include: mydefaults.rc yourdefaults.rc
75 The resources in the first file have higher priority than the
76 second file.
77
78 - general: Now the output files (calib*.root, etc) also contain the
79 resource file (to check it open it in the TBrowser and choose Print()
80 from the context menu)
81
82 - general: Dataset files now allow to overwrite the default path
83 to search for sequence and data files. Note, that the program
84 option and individual resources will overwrite it. For example:
85 SequencePath: /magic/montecarlo/sequences
86 DataPath: /magic/montecarlo/star
87
88 - general: Fixed a problem with variables in MDataPhrase. It seems
89 that only optimdisp (didn't work) was effected.
90
91 - general: Some improvements to the optim and train processing. For
92 example the ststud window now got a proper title.
93
94 - general: The "Status Display: " was removed from the window title
95 within an Eventloop.
96
97 - general: added a new flexible histogram-class (MHn) which can be used
98 for example in testing after optimizations or training to produce
99 user defined histograms.
100
101 - general: The Random Forest now allows attaching an evaluation
102 function which is applied to its output. This allows to train
103 on whatever you like (eg. train on log10(energy), but return
104 energy)
105
106 - general: The Random Forest training of energy (trainenergy.c) and
107 disp (traindisp.C) has been improved by more graphical output to
108 judge the result.
109
110 - general: The training of energy (trainenergy.C) has been improved
111 a lot by training on a different quantity than energy. It gives
112 a result which is highly independant of the source spectrum
113 and shows lower bias than all other options.
114
115 - general: Dataset files are allowed to contain collections of
116 datasets. For more details see the class reference of MDataSet.
117
118 - general: The default WobbleMode in a datset file now (if not
119 overwritten) is "auto", i.e. wobble mode is set if the dataset
120 doesn't contain off-sequences.
121
122 - merpp: Merpp can read file format version 9 now. Please realize
123 that for file format version 9 the extraction range is different
124 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
125 the first and last 15 slices have been removed from all MUX data.
126
127 - mars: Similar to writing movies you can now select events which
128 should be displayed in your display. Therefore add the following
129 lines to your mars.rc:
130 MFEvtNumber.FileName: ganymed00223552.root
131 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
132 The input file can be a ganymed-file after (ganymed*.root) or
133 before (ganymed*-summary.root) file. For example to select all events
134 from your on sample after cuts (excluding the ThetaSq cut) use
135 MFEvtNumber.Selector: DataType.fVal>0.5
136 To show all events from your on-sample after quality cuts
137 use the summary file instead.
138
139 - mars: new ways to call mars are implemented. Instead
140 of calling
141 mars filename.root
142 you can now also use
143 mars sequence.txt
144 or
145 mars sequence.txt inputpath
146 or replace sequence.txt by the sequence number if the default
147 sequence file should be used.
148
149 - mars: The default size has been increased
150
151 - mars: There are two new heckboxes which allow to switch off
152 the calculated image parameters
153
154 - callisto: was broken for MCs... fixed.
155
156 - callisto: improved calculation of spline coefficients a lot. This
157 leads to a further improvement of the event rate calibrating MUX
158 data of about 15% (175evt/s instead of 150evt/s)
159
160 - callisto: finally the raw data we read is now real 16bit (with
161 10bit precision) for MUX data and not a stripped 8bit number
162 anymore. Due to scaling of the numbers (without precision loss
163 into an [0-256[ range, the final numbers for pedestal, pedestalrms
164 and extacted signal don't change. However, at all places where
165 raw data is directly accessed (eg. saturation and variation
166 limits in the signal- and pedestal-extraction) the numbers
167 refer still to the data's 16bit range.
168
169 - callisto: The maximum arrival time difference used in the bad
170 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
171 for both, old FADC and MUX-FADC, data.
172
173 - callisto: Be aware that callisto is now calibrating the arrival time
174 in nanoseconds rather than time slices. Also all following tasks
175 have been changed to assume ns units now. If you star data
176 calibrated with an older version it might be necessary to adapt
177 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
178 to obtain optimal results. The plot in the PulsePos tab
179 will now be in ns, too. This might also mean that the Muon
180 analysis in star might not work as perfect as expected as long
181 as old files read in.
182
183 - callisto: The calibration constants of earlier updates got lost
184 somehow. All constants have been updated.
185
186 - star: The PSF is now determined from the profile of the ArcWidth
187 instead of arcwidth/radius. The old way gave to much weight
188 to the bins with low statistics. The reference lines have been
189 updated.
190
191 - star: For speed reasons events suitable for the muon analysis
192 are now also preselected by fConcCOG<0.1 which seems to be a very
193 good preselector for muons.
194
195 - star: is now calculating a new timing parameter the Slope along
196 the major and minor axis of the shower. Therefore a numerical
197 solution of a line-fit is used. To use MHillasExt.fSlopeLong
198 and MHillasExt.fSlopeTrans don't forget to multiply it with
199 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
200
201 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
202 have been removed from MNewImagePar. They have never been good for
203 anything.
204
205 - star: Implemented a new recursive algorithm which is supposed to be
206 faster. Also implemented new cleaning oiptions, which are:
207 + CleanLevel0:
208 The cleaning level above single core pixels can be kept
209 + KeepIsolatedPixels:
210 Define whether single core pixels should be kept
211 + TimeLevel1:
212 The coincidence window in nanoseconds to single used neighbors
213 + TimeLevel2:
214 The coincidence window in nanoseconds to two used neighbors
215 + PostCleanType:
216 MOde in which a time dependent post cleaning should be applied
217 0: No post cleaning
218 1: Require for each used pixels at least one used neighbor
219 within a time-window of CleanLevel1
220 2: Require for each used pixels at least two used neighbor
221 within a time-window of CleanLevel2
222 3: Require first two and second one used neighbor
223 within a time-window of CleanLevel1 and fCleanLevel2
224 respectively
225 + RecoverIsolatedPixels:
226 - recoveres isolated core pixels if they have a used neighbor
227
228 - mars/star: The new default cleaning is:
229 + CleanLevel1: 6.0
230 + CleanLevel2: 3.0
231 + CleanTime1: 1.75
232 + CleanTime2: 1.75
233 + PostCleanType: 3
234
235 - star/ganymed: The old spark-cuts have been replaced by new ones.
236 These new spark cuts have been cross checked with the sequences
237 84720 (before splitter), 101041 (after splitter) and 223539 (new
238 FADCs). In all cases they seperate pretty well, but of course not
239 perfect. Monte Carlos have suggested to tighten the cuts a little
240 bit further at low sizes. This has been done.
241
242 - ganymed: IMPORTANT - The spark cuts have been changed to match
243 all available data more or less well. This might mean that for
244 YOUR data there are still sparks visible.
245 Whenever you do an analysis you have to make sure that NO sparks
246 survive your cuts!
247
248 - ganymed: The old hadronness and size cuts have gotten new indices
249 (10, 11). The old indices 8 and 9 now mean an additional condition
250 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
251 If you want to switch off this cut just move the line far away enough,
252 e.g. by setting c[9] to -500. Please update your ganymed.rc files
253 accordingly!
254 The unit of c[9] is deg. It is the dist at which your cut will
255 cross the slope==0. The unit of the slope is ns/deg. So if
256 you readin files calibrated with an older Mars-version you
257 have to adapt the default value for c[9] to the FADCs:
258 - Multiply by two for the MUX FADCs (run number > 200.000)
259 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
260 - Multiply by 42 for the meaning of life (run number = 200.000)
261
262 - ganymed: The old Cut0 is now called CutQ and is calculated before
263 the source position is caluclated. If you need a quality cut
264 including source dependant data (be very carefull with this!)
265 you have to use Cut0 instead.
266
267 - ganymed: now properly supports three off regions in wobble mode.
268 It will be the default from now on in ganymed_wobble.rc. To change
269 the number of off-regions use
270 NumOffSourcePositions: 1
271 in your ganymed.rc. Also by default no off-theta cut will be done
272 anymore so that you will get a background level higher than the
273 signal level in your ThetaSq plot for ThetaSq>0.2.
274 Due to this be carefull changing the scaling mode away from
275 "None". You will underestimate your signal if your scale interval
276 is not properly set.
277 (Rem: ThetaSqN is no longer needed)
278
279 - ganymed: is now storing the events of all (on- and off-)
280 source positions even in the case of more than one off-source
281 position. This should allow sponde to work properly and the
282 energy estimation is done correctly in all cases (without any
283 "nearest position" trick)
284
285 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
286 with a real pointing model for the starguider is done, calibrated
287 with more than thousand tpoints taken from this date on.
288
289 - ganymed: was broken for Wobble-MCs... fixed.
290
291 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
292 has changed. Note that your old ganymed.rc will be incompatible
293 with the new algorithms! Please check the ganymed.rc files and
294 the class description of MFMagicCuts for more information.
295 It is recommended at the moment to use identical Disp-Parametrizations
296 for on/off- and wobble-mode. If cuts are optimized only
297 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
298 should be optimized. All other values should be kept as they are.
299 If you want to do an anylsis without timing a parameters, you can
300 switch off the timing cuts by seeting parameter 7 to a very small
301 value (eg. -99). To remove the slope parameter from the disp
302 paremtrization set parameter 8 to 0.
303
304 - ganymed: The distribution of observation time versus zenith
305 angle is now shown for off- AND on-data.
306
307 - ganymed: The contents of the source position plot are no longer
308 averaged, thus a lot of (fake) events between the two wobble
309 positions have disappeared.
310
311 - ganymed: There is a new tab "CutT" it contains the VsSize plots
312 with the CutT, whihc is defined in ganymed.rc, applied. It
313 is resonable to use your theta-cut for it, to see if there is
314 something strange (sparks!) in your signal-region.
315
316 - ganymed: To choose a dataset from a collection in a dataset file
317 use the new command line option "--dataset=12345"
318
319 - optim, sponde: should now properly support three off-regions.
320 Just produce your ganymed summary files with three off-regions.
321 optim and sponde will automatically get all off events from
322 all off-regions from this file. Please do not forget to
323 set the scaling in optimwobble.C properly:
324 fit.SetScaleUser(1./3);
325 it is not yet read in automatically (will follow soon).
326 In the case of fixed Scale you can also use
327 cuts.SetThetaCut(MFMagicCuts::kOn);
328 no off-cut needed.
329 Be carefull in case of three off-regions when switching on
330 scale mode. Make sure that the scale interval is set correctly.
331
332 - sponde: sponde.rc and sponde_onoff.rc are now idetical
333
334 - sponde: the resouce files have been rewritten with a lot of
335 comments and a well working parametrization for an energy estimator
336
337 - sponde: In the estimated energy versus monte carlo energy plot the
338 contents where exchanged.... fixed.
339
340 - sponde: the so called "accurate"-mode has been removed. It didn't
341 give any improvement in accuracy, only decreased execution speed.
342
343 - sponde: the so called "simple"-mode has been removed. It didn't
344 give any improvement in simple.
345
346 - sponde: the so called "refill"-mode has been removed. It was anyhow
347 not implemented.
348
349 - sponde: now checks whether the theta distribution of your on-data
350 and the theta-distribution of your Monte Carlo sample (after
351 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
352 sample is incomplete) execution is stopped. Execution can be forced
353 using the new option --force-theta. Use this option with care!
354
355 - sponde: Proper collection areas can now be constructed also from
356 Monte Carlo samples generated with different maximum impact
357 parameters. Note that in previous version you neither got
358 a warning or failure, nor was there any obvious sign that the
359 collection area was overestimated due to usage of files with
360 different maximum impact parameters.
361
362 - sponde: If MC files with different lower energy limits are used
363 the primary MC spectrum is artificially completed down to the
364 lowest energy used at all. WARNING: that this gives correct
365 collection areas ONLY if none of the events in this region would
366 survive your cuts at all.
367
368 - sponde: the output file now contains more information about
369 the spectrum (eg. the full 2D collection area histogram).
370 Note, that this information can only be written to the file
371 if it is stored automatically via command line argument.
372 If you only store the status display from within the display
373 the information is lost.
374
375 - sponde: added a new tab "Disp". It shows the residual of the disp
376 (Disp-Dist) versus several parameters and it is meant to judge the
377 quality of the disp estimator. In the ideal case the residual is zero
378 and doesn't depend on any variable. The tab is displayed after
379 CutQ and Cut0.
380
381 - sponde: added a new tab "Energy". It shows the residual of the
382 energy (lg(estimated energy)-lg(monte carlo energy)) versus
383 several parameters and it is meant to judge the quality of the
384 energy estimator. In the ideal case the residual is zero
385 and doesn't depend on any variable. In reality even a good estimator
386 can show residuals versus Monte Carlo energy. The tab is displayed
387 after all cuts.
388
389 - sponde: added a new tab "EventDist" showing the unweighted real
390 absolute number of events of your sample after cuts. This tells
391 you how many events with this energy you had in your MC files.
392 The same information you get from the error bars of the weighted
393 histograms, but this is less intuitive.
394
395 - sponde: The spectrum plots now show the crab- and 1553-spectrum
396 for comparison. It is not meant to show these curves in
397 publications, they are only for production.
398
399 - sponde: The OriginalMC tree with the events produced by corsika
400 is now processed only once
401
402 - sponde: Finally fixed most annoying bug, which has effected the
403 last bin of the collection area. It was the problem that binnings
404 of root histograms are from 1 to n (included) but there was a C-like
405 loop in sponde from 0 to n (excluded). Now the loop also includes
406 correctly under- and overflow-bins. The worse thing with this is,
407 that for the events in the highest bin not only the bin-content
408 was wrong, but also the weights applied to these events, which could
409 in pricipal effect also other parts of the distribution (eg. due
410 to energy estimation). Fortunately it effected only a few events
411 in most cases.
412
413
414
415 *** Version 1.2 (2007/05/14)
416
417 - database: The database now has two new values Unsuitable50 and
418 Unsuitable01. They express the number of pixels which are
419 unsuitable for more than 50%, respectively more than 1%, of
420 all calibrated event. It is a more accurate number than the
421 previously used numbers, because they only take the first
422 calibration (ignoring the interleaved calibrations) into account.
423
424 - database: The database now has two other new values UnsuitableMax and
425 DeadMax. They express the maximum number of pixels which were
426 unsuitable, respectively dead, during the sequence. Because
427 of high pedestal rms (cars passing) a few events with very high
428 numbers of unsuitable pixels can happen. Not to suffer from this
429 effect we don't take the highest 0.1% of the numbers into account.
430
431 - general: fixed a bug which caused callisto and star to stop working
432 properly because the callisto output was currupted
433
434 - general: a script called scripts/makemovie has been added which
435 simplified the process of producing several movies from a single
436 sequence with different setup.
437
438 - callisto: Some more code cleanup. Started to remove old obsolete
439 code from cvs.
440
441 - callisto: The extraction of the pedestal with the extractor was
442 not random. It seems that extracting at one position is still biased
443 (for example in the first or last slices we could still suffer from
444 switching noise) Now it is completely random.
445
446 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
447 pedestal files) individual pixels could be skipped due to high
448 variations. This was already the case for the pedestal extraction
449 from the lo-gains since the beginning and properly handled
450 there, but was introduced in the extraction from the pedestal files
451 a while ago. To calculate the average value it was still divided
452 by the number of events procesed not by the number of summands
453 really summed. This let to a pedestal which was a tiny amount too
454 small (for a few piels in the order of 0.1%). This led to an slightly
455 positive offset of the randomly extracted pedestal for a few pixels.
456 I doubt that this has a big effect on the result, because the effect
457 on the individual numbers is quite small. Due to this it is suggested
458 that you rerun your calibration to make sure you are without any
459 avoidable bias.
460
461 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
462 the median rms of the absolute arrival time and expressed in significance
463 levels. This replaces the old meaning of an abolute upper limit. An
464 absolute upper limit doesn't make much sense, because in our data
465 all arrival times are shifted at the same time (in fact it might be
466 a shift of the artificial trigger w.r.t. to the light flash).
467
468 - callisto: Added a new tab "BadPixTm" which shows the time evolution
469 of the number of unsuitable pixels over the whole sequence. This
470 is usefull mainly to judge if an intermediate calibration had
471 problems.
472
473 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
474 of the number of dead pixels over the whole sequence. Dead pixels
475 in this context are unmapped pixels, i.e. pixels which could not
476 be interpolated, and thus are ignored in the further analysis.
477
478 - callisto: It is now possible to use the position of the maximum
479 of the spline as arrival time instead of the leading edge even
480 when using the integral for the signal. Therefor set the extraction
481 type to kIntegralRel ("IntegralRelative") and the relative height
482 ("HeightTm") to -1:
483 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
484 MJPedestalC1.ExtractSignal.HeightTm: -1
485
486
487
488
489 *** Version 1.1 (2007/04/27)
490
491 - general: The new class MGeomCamDwarf contains the camera geometry
492 for our prefered Dwarf camera and can be used to create general
493 geometries of roundish or hexagonal cameras.
494
495 - mars: The default cleaning is now abolute 8.5/4.0.
496
497 - mars: The resource file mars.rc now contains examples for MUX data
498
499 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
500 data containing only 10-bit information is still cooked down to
501 8-bit, by cutting away the lowest 8-bit.
502
503 - merpp: When reading raw data the data is now stored in a single
504 array. The lo-gain array is obsolete. The interface stays the same.
505
506 - callisto: To process the new MUX data use the resource file
507 callisto_mux.rc
508
509 - callisto: The -root and -raw options to read merpped raw data have
510 been removed
511
512 - callisto: If the -mc option is given the sequence-name can now be
513 replaced by the MC sequence number
514
515 - callisto: If the sequence file contains "MonteCarlo: Yes" the
516 -mc option can now be omitted
517
518 - callisto: Started further simplification by removing obsolete
519 dependancies on MCalibIntensity*Cams.
520
521 - callisto: removed unsused intensity calibration from MJCalibration
522 for further simplification
523
524 - callisto: for simplification removed references to
525 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
526 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
527 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
528 (this should at minimum change nothing at all, and at maximum
529 improve thing if these containers where somewhere not handled
530 properly)
531
532 - callisto: Added the option to write an event movie. Please use
533 this option with care (huge files) but exessively to understand
534 our events. For further documentation please refer to the
535 IACT wiki
536 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
537
538 - callisto: Improved binning for the pulse position check histogram
539
540 - callisto: The code calculating the pulse position checknow takes
541 the pedestal into account
542
543 - callisto: The arrival time is now stored with full precision this
544 helps to get rid of artefacts in histograms. For the signal this
545 is not necessray because it is displayed in log-scale anyhow
546
547 - callisto: Fixed a problem with internal exclusions. Pixels which
548 have once been marked as unsuitable didn't get the necessary
549 histograms filled anymore to be rechecked with each interleaved
550 calibration.
551
552 - callisto: The relative arrival time resolution (the rms of the
553 relative arrival time offset) is now checked against its
554 median and the median deviation, instead of the average
555 plus an absolute offset.
556
557 - callisto: The relative arrival time offset is now calculated
558 w.r.t. its median not w.r.t. to an artificial reference pixel.
559
560 - callisto: The relative time calibration now marks pixels with
561 outlaying offset as unsuitable
562
563 - callisto: The interleaved relative time calibration has been switched
564 on. The advantage is that pixels which are marked as outliers
565 now can recover. An improvement over time is not expected, because
566 the relative time calibration seems stable.
567
568 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
569 option can now be omitted.
570
571 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
572 or the option "-mc" is specified as default the monte carlo datacenter
573 paths (/magic/montecarlo/...) are used if not overwritten in the
574 dataset file.
575
576 - ganymed: The output files now contain run- and event-number for all
577 events, accessible as RunNumber.fVal and EvtNumber.fVal
578
579 - ganymed: Added a plot showing the source position in the camera also
580 for wobble mode
581
582 - ganymed: In addition to the existing task which can be setup to
583 be executed after Cut1 a final task called "EstimateEnergy"
584 has been added, executed before writing the final output
585 (ganymed00000000.root). The task setup in all three cases
586 can be choosen individually. (For all three(!) cases you
587 can for example choose MRanForestCalc. For examples see all
588 sponde*.rc and all ganymed*rc)
589
590 - ganymed: If a container "MEstimatedEnergy" is found in the
591 parameter list (eg. because it was setup by MEstimateEnergy)
592 it will be written to the output file.
593
594
595
596 *** Version 1.0 (2007/02/16)
597
598 - database: Website to plot values from the database has been added.
599
600 - database: The rate of spark events as found by star is now kept
601 and the rate after cleaning is now with spark events subtracted
602
603 - general: The changes to the interpretation of phrases lead to
604 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
605
606 - general: Added example files how you can create your own calendar
607 (eg. as christmas present) with Mars. Just run
608 root macros/tutorials/calendar.C
609
610 - general: Added a possibility to display grouped data in the plotdb.C
611 macro (and similar macros). This allows to plot hourly, nightly,
612 weekly, monthly and yearly averages.
613 For more details see the plotall function of the macro
614
615 - general: fixed the error display of the camera display. It showed
616 wrong results.
617
618 - general: fixed a memory leak when reading many MStatusDisplays
619
620 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
621 between a spherical and a parabolic mirror
622
623 - callisto: We have a new pulse position check which takes the properties
624 of the extractor automatically into account. So no need to set
625 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
626 left is done. If possible the lo-gain extraction start and hi-gain
627 extraction end is changed accordingly. If no proper extraction range
628 can be set (hi-gain too much to the left) an error is raised.
629
630 - callisto: New swapped pixels have been found and corrected
631
632 - callisto: Redone the signal extraction this includes:
633 + Unified the algorithms to extract the pedestal for all pedestal
634 extractions done
635 + Unification of hi- and lo-gain into one array
636 + Unification of hi- and lo-gain extraction for Spline and
637 Digital Filter (means now exactly the same algorithm is used,
638 not a copy-and-pasted one)
639 + Store pedestal subtracted data in a common place
640 + Improved extraction algorithms. If the algorithms search a
641 maximum but don't find one they don't return the maximum anymore
642 + Improved the extraction such that a information for signal
643 and time which is consistent is returned
644 + replaced the numerical spline with a (not slower) analytical
645 solution
646 + Lowered the saturation limit from 250 to 245 to make sure that
647 we are far away in all pixels from problems with the clock-noise
648 + The start of the lo-gain extraction is calculated from the hi-gain
649 arrival time. In case of saturation an estimation is used.
650 + the hi-gain window was extended to slice 16. This allows extraction
651 of very late pulses in single pixels or of huge hadron showers.
652 + Now uses the lo-gain extraction range for pedestal extraction,
653 not the hi-gain range in the lo-gain
654
655 - callisto: New hi-/lo-gain calibration constants have been produced
656 for all periods from the statistic of the whole period. They are
657 now used automatically depending on the periods. The old constants
658 where deviation in avarega about 2%-3%. The constants are very
659 stable from period to period (<<1%) except for exchanged channels.
660 In a few cases the constants used so far were off by 1%-2% (maybe
661 temperature effects?)
662
663 - callisto: To gain obsolete space we do not write the
664 MPedestalFundamental anymore. Also calibration and bad pixel
665 treatment is not done for it anymore because it has never been used.
666
667 - callisto: Fixed a bug in the seuqence handling which caused the
668 light condition to be ignored
669
670 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
671 basically the same as "Cleaned" but the distribution devided into
672 the events fullfilling a spark cut or being rejected by it.
673 This cut can be changed from star.rc (see example inside) by
674 the "SparkCut" directive
675
676 - star: Star displays now the average individual pixel-rate (IPR) versus
677 time and the average discriminator threshold (DT) of all pixels.
678
679 - optim: fixed a problem with the optim-macros which was due to a bug
680 in the new phrase parsing
681
682 - ganymed: To get a nice FalseSource plot (instead of the all-information
683 debug plot displayed as a standard plot) use the context menu
684 somewhere between the two upper plots, click on "DrawNicePlot"
685 and enjoy the result. (It is the same context menu which contains
686 the other options)
687 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
688
689 - ganymed/optim/train: The cut program, trainings- and optimization
690 macros could run with less files found than expected from the
691 sequence-files. No the execution is stopped in this case.
692
693 - ganymed: now stores the dataset in the output file with all information
694 contained (as sequence number, sequence path, data path) so that the
695 used dataset file can be recreated complete from the output
696
697 - sponde: now also allows the uasge of random forest
698
699 - sponde: added a plot showing the cut efficiency
700
701 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
702 errors (eg. effecting the collection area) because the errors of the
703 two histograms were swapped in the calculation, which makes a difference
704 in the case the histograms contains weighted events. Aditionally the
705 totalarea was incorrectly taken into account, which results in too small
706 errors, which makes a difference at low statistics were the errors
707 or the collection area dominate.
708
709
710
711 *** Version 0.10.3 (2006/10/23)
712
713 - database: Implemented ObservationMode flag in websites.
714
715 - database: For sequences there is now also the stoptime available on the
716 websites.
717
718 - database: Removed ManuallyChanged flag from sequence-info websites,
719 as it is not needed anymore with the new sequence building algorithm.
720
721 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
722 Class for calculation of confidence intervals (upper limits).
723 Use model 3 or 4 for upper limit calculation for MAGIC observations.
724 Please read the class instruction of TRolke for more information.
725
726 - general: The programs now return 0xfe if the requested resource file
727 doesn't exist.
728
729 - general: Errors comming from root itself are now not output to
730 stderr anymore but to our default (colored) log-stream.
731
732 - general: Changed the interface to TFormula such that now everything
733 is parsed by TFormula, which should allow to use phrases even
734 without paranthesis correctly parsed.
735
736 - callisto: replaced the AdHoc number of effective integration slices
737 in the digital filter by an average of the correct number, averaged
738 over all possible set of weights. This also gives correct numbers
739 for the lo-gains which were totally wrong before.
740
741 - callisto: drastically reduced memory consumption by not storing
742 all intermediate calibration results in memory anymore (we might
743 write them into a file in the future)
744
745 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
746 debug plot displayed as a standard plot) use the context menu
747 somewhere between the two upper plots, click on "DrawNicePlot"
748 and enjoy the result. (It is the same context menu which contains
749 the "DrawAll" option)
750 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
751
752
753
754 *** Version 0.10.2 (2006/10/15)
755
756 - general: changed the building of the sequence files such, that
757 the source-/project name in case of wobble-sources is not the
758 source/project of the first data run anymore but the new generalized
759 wobble source/project
760
761 - general: Added some functions to MAstro to calculate sun and
762 moon properties
763
764 - general: Added two new macros (starvisday.C and starvisyear.C)
765 which allow to plot the visibility of several stars in one day
766 or of one star along one year
767
768
769
770 *** Version 0.10.1 (2006/10/11)
771
772 - general: HTML logging output was distorted... fixed.
773
774 - general: Changed the writing of the sequencefiles such that only
775 as many pedestal files as giving at least 1000 pedestal events which
776 are nearby the first calibration run are used as pedestal runs
777
778 - sponde: In the calculation of the collection area(s) and the
779 distribution for MOnte Carlo and estimated energy the error
780 calculation was wrong because root didn't take the errors
781 properly into account... fixed.
782
783
784
785 *** Version 0.10 (2006/10/10)
786
787 - general: all executables now check consistency of the root version
788 installed with the root version used for compilation. The return
789 code in this case is 255.
790
791 - general: The algorithm to build seqeunces has been redesigned
792 completly. It is now more flexible in terms of a resource file
793 resources/sequences.rc which can be used to partly overwrite
794 the default algorithm and defined the important part of the
795 algorithm. It also takes correctly into account several ways
796 of taking wobble-data. Currently the new algorithm doesn't take
797 the number of pedestal events anymore into account (so a sequence
798 could have much less than 1000 pedestal events and data runs are
799 no-more used instead)
800
801 - general: a lot of small changes to make the code compatible with
802 root 5.12/00 and gcc 4.1
803
804 - general: Fixed some warnings thrown if more warnings are switched
805 on in the compiler
806
807 - general: Added a function to MMath which returns the Median of
808 the distribution abs(y[i]-median) but at 68:32 division instead
809 of 50:50, which is somehow the median counterpart of the rms.
810
811 - general: MAstroCatalog allows now to read calatog files (as bsc5)
812 even if they are compressed with gzip (recommended compression
813 is with "-1")
814
815 - showplot:
816 + batch mode creation of image files now works with root 5.12/00
817 + added support for writing bmp (though it never produces
818 bmp which can be read by programs like xv or gimp)
819 + added support for xml
820 + added new option to start the display with a different size, by
821 --display-width=nnn or --display-height=nnn
822 + added options to define the canvas size when the display is started
823 --canvas-width=nnn or --canvas-height=nnn
824 the option can also be used for batch-mode conversion
825 + added an option which automatically fits the display size to the
826 desktop-size: --auto-size
827
828 - merpp: didn't recognize files with the extension .raw.gz - fixed.
829
830 - merpp: allow the reports to have 1000ms due to a bug in the camera
831 program.
832
833 - callisto: New swapped pixels have been found and corrected. For
834 details see MRawRunHeader::FixAssignment()
835
836 - callisto: Callisto now raises an error if one of the input files could
837 not be opened.
838
839 - callisto: In some rare cases it could happen that in the signal
840 extraction of the digital filter the extractor returned nonsense
841 results due a wrong initializion of a variable (this happens in
842 cases in which the extracted signal is exactly zero or the
843 digital filter couldn't slide because of a too small extraction
844 window, which could happen in the lo-gain extraction)
845
846 - callisto: The lo-gains have been marked as valid in some cases
847 when they got not extracted at all (deltsumlo=deltatimelo=0) because
848 the allowed extraction range (fLoGainLast-fLoGainFirst) was
849 smaller than the number of slices (fLoGainWindowSize) needed
850 by the lo-gain extractor
851
852 - callisto: Updated absolute calibration constants (muon calibration)
853
854 - callisto: fixed a bug which caused the hi-gain saturation not
855 to be handled properly in the spline (the position of the
856 saturation was calculated incorrectly)
857
858 - callisto: fixed a bug which gave weird results if hi- _and_
859 lo-gain could not be extracted properly. In some cases hi-
860 and lo-gain have not been extracted at all and the random result
861 got calibrated. In other cases the hi-gain was saturating and the
862 lo-gain has not been extracted. For this a completly arbitraty
863 scale factor was applied to the result from extracting the
864 charge of the saturating hi-gain.
865
866 - callisto: improves handling of extracted signal if lo- and/or
867 hi-gain could not be extracted properly. If no appropriate
868 calibration of either the signal or the arrival time is possible
869 the pixel is now markes as unsuitable instead of estimated.
870
871 - callisto: Fixed a problem in the spline extraction which gave
872 weird results if the signal was extracted from the first (and
873 highest) slice (as a workaround extraction from the first
874 slice has been forbidden)
875
876 - callisto: Fixed a bug regarding the use of the QE which doesn't
877 effect the result because the default is used anyhow.
878 (The bug was there since 14/07/2005)
879
880 - callisto: Changed the default for fgLoGainStartShift to -2.4
881
882 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
883 factors to be always 10 for all pixels as soon as the first
884 calibration update has happend.
885
886 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
887 was off by more than one slice (which gives wrong values for
888 pixels which have saturated the hi-gain) This was a problem
889 mainly for timing studies, not so much for the automatic standard
890 analysis. Also the values for the Spline have been changed slightly:
891 + Digital Filter from 1.70 to 0.95
892 + Spline from 1.39 to 1.30
893 The numbers were sorted out by an extensive test in the
894 test-database.
895
896 - callisto: Removed the tab showing the average calibrated arrival
897 time. It never gave useful information.
898
899 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
900 lo-gain pulse for data pulses if hi- and lo-gain have saturated
901 and both were extracted because the hi-gain was above the
902 LoGainSwitch.
903
904 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
905 lo-gain pulse position (after application of LoGainOffset, which
906 means in the ideal case it is 0) for data pulses if hi- and lo-gain
907 have saturated and both were extracted because the hi-gain was above
908 the LoGainSwitch.
909
910 - callisto: After extensive tests a new threshold level for determination
911 of the pulse position has been found at 50phe. This is due to the
912 fact that for lower pulses the arrival time changes its average
913 behaviour dramatically. It tends to the average of the extraction
914 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
915
916 - callisto: Added two more plots to the calibration part. The average
917 extracted signal and the average extracted arrival time as
918 extracted by the signal extractor (This can help debugging problems
919 because it doesn't involve a fit)
920
921 - star: changed the fit for the effective on time such that initial
922 values are calculated automatically now instead of using build
923 in values. This makes the fit more indepedant of the underlaying
924 rates. With a test of ~350 sequences in the test database it could
925 be shown that the new fit gives the same result +/-1sek.
926 The highest deviation was +5s the lowest -10s. You can now control
927 the bahaviour with two resource values:
928 MHEffectiveOnTime.FistBin: 3
929 MHEffectiveOnTime.NumEvents: 12000
930 Use FirstBin=1 and NumEvents=120 to fit the effective on time
931 from the resulting gamma candidates
932
933 - star: The Center histogram in MHHillas is now by default displayed
934 with the colz draw-option
935
936 - ganymed: now produces valid error codes if failed
937
938 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
939 with the option "hadronness" instead of "area" or "both" if
940 you want to use both cuts. The hadronness cut includes a fixed
941 cut in hadronness (index 8) and a fixed cut in size (index 9).
942
943 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
944 the M3Long of the anti source to be not properly evaluated
945 (actually is was evaluated as a unique random number) in case
946 of optimization with anti-theta cut switched on. This might have
947 lead to improper, but not necessarily wrong, optimization results.
948
949 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
950 how to use random forest
951
952 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
953 ganymed_onoff.rc. Seems to be unintentional that they were different.
954
955 - sponde: Since the introduction of the possibility to define a
956 normalization energy instead of using the integral the default
957 was not using the integral anymore but a normalization energy of
958 1GeV. It is now the integral again.
959
960 - sponde: Fixed a problem in the weighting which did not allow
961 a MC slope of -1.
962
963
964
965 *** Version 0.9.6 (2006/05/24)
966
967 - general: changed the binning of the azimuthal profile of the camera
968 such that it is aligned with the 60deg boundaries.
969
970 - merpp: better handling of problems with the TH, TD part of the
971 CC-REPORT for files older than 200507190 and 200412210
972 respectively
973
974 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
975
976 - merpp: implementd latest changes in starguider reports (sinc 9th May)
977
978 - callisto: if an arrival time is extracted outside the fadc range is
979 was set to the boundary before. Now a random number is assigned
980 instead to avoid unfortunate coincidences of arrival times just
981 by this arbitrary value.
982
983 - callisto: added a new option to callisto.rc which allows
984 to set the maximum arrival time difference allowed for the
985 badpixel algorithm to determin whether a pixels belongs to a shower:
986 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
987
988 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
989 to 0.9 as suggested by Stefan due to a recent study on the fraction
990 of pixels surviving the image cleaning
991
992 - callisto: switched off error in case of "pulse is too much to the left"
993
994 - callisto: The extraction window is not adapted anymore. This means that
995 the pulse is extracted from the full range. The draw-back is that the
996 background (pedestal) will become slightly higher. Switching on/off
997 the PulsePosCheck in the callisto.rc only effects filling the
998 histograms.
999 WARNING: If the pulse is too much to the left data is calibrated!
1000 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1001 in the database to make sure that your data is valid!
1002
1003 - star: Show also the number of stars correlated correctly by the
1004 starguider
1005
1006 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1007 than one off-source region in wobble-mode. To use it add the following to
1008 your ganymed_wobble.rc:
1009 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1010 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1011 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1012 + Cut1.ThetaCut: None
1013 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1014
1015 - ganymed: in the case the latest report is older than a default (currently
1016 one minute) and the current report will be skip the starguider
1017 correction and calibration will be reset. The maximum age can be
1018 setup from ganymed.rc by (minutes):
1019 MPointingDevCalc.MaxAge: 1.5
1020
1021 - ganymed: A first implementation showing all size-bins for the theta-sq
1022 resp. alpha-plots in a single tab automatically
1023
1024
1025
1026 *** Version 0.9.5.1 (2006/05/05)
1027
1028 - general: Added a new option "zdiff" to the Makefile which runs
1029 "cvs diff" as "make diff" would do, but with compression
1030
1031 - general: accelerated MTFillMatrix (used for eample in all training
1032 and optimization macros) by skipping some obsolete calles in the
1033 eventloop the first and second loop could be accelerated by ~20%
1034
1035 - general: Added a missing feature in the MFilterList class which
1036 prevented MFEnergySlope from working correctly in trainenergy.C
1037
1038 - general: Accelerated the random forest training and usage a bit
1039
1040 - merpp: Adapted to new raw data file format version 6
1041
1042 - merpp: fixed a problem with reading the starguider reports
1043 after 6.3.2006
1044
1045 - callisto: At some times six pixels had to be exchanged manually in the
1046 data. If the pixels to be swaped are both not found, an error was raised
1047 and calibration was stopped. Now it is assumed they are intentially not
1048 mapped and the Error has been changed to a Warning.
1049
1050 - star: Added new image cleaning based on the arrival time of the shower.
1051 The new cleaning can be accessed using the parameter "Time" instead of
1052 the the old one (like "Absolute) in the star.rc-file.
1053 Recommended parameters:
1054 + MImgCleanStd.CleanLevel1: 8.2
1055 + MImgCleanStd.CleanLevel2: 5
1056 + MImgCleanStd.CleanRings: 2
1057 + MImgCleanStd.KeepSinglePixels: No
1058
1059 - star: Simplified the calculation of the effective on time. By letting
1060 the fit start in the third bin the result should become more stable.
1061 The fit quality is now ignored for the theta-plot which is not used
1062 in the analysis later. Still better pre-cut which, for example,
1063 remove events triggered by car-light (rate changing on a short
1064 time-scale) are missing.
1065
1066 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1067 for optimization (kWeakSource) which is suggested by the Berlin
1068 people for weak sources.
1069
1070 - macros: plotdb.C:
1071 + if no dataset and no time-interval is given only sequences with
1072 an effective on-time above five minutes are plotted anymore
1073 + added a new tab "RelTime" displaying the relative on-time
1074 (effective on-time divided by the observation time)
1075
1076 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1077 the optimization became a lot faster
1078
1079 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1080 To display them just delete the pads displayed on top.
1081
1082 - ganymed: fixed a bug which could cause strange behaviour in wobble
1083 mode if no starguider information was available due to an incorrect
1084 initialization of the starguider calibration
1085
1086 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1087 be changed from within the plot. It can also be setup from the
1088 resource file using:
1089 + MHDisp.fScaleMin: 0.325
1090 + MHDisp.fScaleMax: 0.475
1091
1092 - ganymed, showplot: Fixed a problem with the fit to the off-data
1093 (HistOff) which could cause a time lag or an inifinite loop.
1094 The bug did not effect the results at all.
1095
1096 - sponde: Added a new tab showing the effective collection area after
1097 trigger (including the software trigger)
1098
1099 - sponde: MMcSpectrumWeight has a new option which allows to define
1100 the scaling factor not by the integral of the events but at
1101 a defined energy:
1102 e.g. MMcSpectrumWeight.NormEnergy: 200
1103
1104 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1105 eventloops the loop could be accelerated by ~20%
1106
1107
1108
1109 *** Version 0.9.5 (2006/03/13)
1110
1111 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1112 and added the standard Disp-parametrization
1113
1114 - macros: added a new macro datacenter/macros/plotstat.C allowing
1115 to plot statistics about the data processing
1116
1117 - macros: added a new macro to plot the muon correction coefficients
1118 versus period (macros/plot/mucal.C)
1119
1120 - showplot: path inflation for ganymed files was broken
1121
1122 - callisto: Fixed an important bug. When the number of saturating pixels
1123 were calculated the bad pixel information already available from the
1124 calibration was ignored. This yields wrong values in case pixels
1125 are broken and saturate all the time or randomly.
1126
1127 - callisto: Updated Muon calibration constants. Spline data now also uses
1128 different values for different periods
1129
1130 - star: The time-evolution shown in the effective on-time plot now displays
1131 the axis range (if there are no holes it should be similar to the
1132 effective on-time)
1133
1134 - star: Added two new image parameters:
1135 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1136 the three pixels next to the center of gravity and the size
1137 + MNewImagePar.fConcCore: The ratio of the signals of all
1138 pixels inside or touching the ellipse and the size
1139
1140 - ganymed: now stops in requested source isn't found in catalog file
1141
1142 - ganymed: Many improvements to the phi-plot in wobble mode:
1143 + with a template the ideal background is displayed
1144 + a possible camera inhomogeneity is taken into account
1145 + the anti theta cut is better supported
1146 + the phi cut is automatically calculated from the theta cut
1147 See the examples in ganymed_wobble.rc for more details.
1148
1149 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1150 times the bin-width instead of the absolute energy
1151
1152 - ganymed: New cuts for on/off and wobble mode
1153
1154 - ganymed: The smearing of the False Source plot has been increased
1155 to 0.06
1156
1157 - ganymed: The starguider calibration can now be changed from the
1158 resource file.
1159 See the examples in ganymed*.rc for more details.
1160
1161 - ganymed: added a new option for on-/off-observations
1162 MJCut.RandomSourcePosition
1163 If switched on the distribution of observation time of the source
1164 position in the camera is calculated from the on-data and randomly
1165 applied with this distrbution to the off-data.
1166
1167 - ganymed: by skipping some obsolete calles in the eventloop the
1168 first and second loop could be accelerated by ~20%
1169
1170 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1171 position in the off-data randomly according to its distribution in the
1172 on-data.
1173
1174
1175
1176 *** Version 0.9.4.3 (2006/02/13)
1177
1178 - general: Fixed a bug in most of the programs which prevented the
1179 compile date in the startup message to be displayed
1180
1181 - general: Simplified program calls. The following abbreviations
1182 are now possible:
1183 showlog callisto 55599
1184 showplot signal 55599
1185 star 55599
1186 callisto 55999
1187 ganymed 2
1188 In this cases the corrsponding root-, log-, sequence- or dataset-
1189 filename is automatically compiled using the default datacenter
1190 paths ("/magic/*")
1191
1192 - general: Fixed a long outstanding bug which made axis tick marks
1193 disappear if MDataFormula was used (eg. abs(x))
1194
1195 - general: Updated MMath with new functions to calculate the results of
1196 a exponential, logarithmic and powerlaw fits analytically.
1197
1198 - general: Updated some macros with comments:
1199 + macros/optim/optimdisp.C
1200 + macros/optim/optimenergy.C
1201 + macros/optim/optimwobble.C:
1202
1203 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1204 files) now allows adding a pre-cut like in the optimization. E.g. this
1205 is useful to perform g/h-separation cuts before training the random
1206 forest.
1207
1208 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1209 correctly assigned in the raw data assignement table. A fix to correct
1210 the assignment tabel have been implemented.
1211
1212 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1213 by 90, 180 and 270 deg.
1214
1215 - general: the macro plotdb.C now allows to highlight sequences belonging
1216 to a datset. For more details see the descritions in the macro.
1217
1218 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1219 of the display, it gave wrong results espacially for big sizes.
1220 Now the embedded canvas should always have a ratio width/height=3/2.
1221 The "Size" options have been updated with values fitting the 3/2
1222 size ratio.
1223
1224 - RanForest:
1225 + Updated the random forest classes to support also the
1226 regression method implemented by Thomas H.
1227 + added new tutorial macro how to train the random forest
1228 for energy estimation (macros/optim/rfenergyest.C)
1229 + new classes to train the random forest (still in development)
1230 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1231 + new tutorial macros for random forest training in macros/train
1232 trainenergy.C, traindisp.C, trainseparation.C
1233
1234 - mars: now allows to setup a cut in the resource file mars.rc to choose
1235 the events to be displayed, eg:
1236 Cut.Condition: {0} && {1}
1237 Cut.0: MHillas.fSize>100
1238 Cut.1: MHillas.fSize<900
1239
1240 - merpp: Made aware of the new .rep format 200510250. This includes
1241 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1242 the discriminator thresholds (MCameraTD) and the disciminator
1243 delays (MCameraTD). All of them come with the CC report and are therefor
1244 written to the CC tree.
1245
1246 - callisto: fixed a bug in the calculation of the arrival times in
1247 the Digital Filter. They were all shifted by the same amount
1248 fHiGainFirst. This caused an offset in the order of the position of
1249 the left border of the extraction window in the times calculated
1250 from high-gain and from low-gain. The bug effected only the absolute
1251 arrival times. The bug was there since 30.1.2005.
1252
1253 - callisto: Changed the ExtractionWindow for the pulse position check
1254 such that the camera inhomogeneity becomes as less as possible and
1255 comparable to the pulso position check switched off. More details
1256 on the study will be given at our result web-page.
1257
1258 - ganymed: ganymed.rc, ganymed_onoff.rc:
1259 changed to new cuts trained with 1ES1218 and Crab-data
1260 for maximum sigma*log10(excess)
1261
1262 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1263 a new option was implemented to estimate Disp (CalcDisp)
1264
1265 - ganymed: Implemented two new options which allow
1266 to overwrite the default path to search for the sequence files
1267 --ins=/magic/sequences
1268 and where to search for the image data
1269 --ind=/magic/data/star
1270
1271 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1272 dx/dy from the resource file by
1273 MSrcPosCorrect.Dx
1274 MSrcPosCorrect.Dy
1275
1276 - ganymed: fixed reading the source catalog. Only as many chars
1277 as the requested source name had were compared (If a source
1278 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1279 were requested it could happen that the coordinates of
1280 "1ES1218" were read) The source coordinates are now printed
1281 in addition to its name to the logging output.
1282
1283 - ganymed: changed the background fit in the case of a ThetaSq function
1284 from a polynomial to a exponential, this should give a big improvement
1285 for on-only analysis'
1286
1287 - ganymed/sponde: Calculation of the error of single size-/energy-
1288 bins now uses Li/Ma (5) instead of LiMa (17)
1289
1290 - sponde: Added a plot E^2*dN/dE
1291
1292 - sponde: The energy estimator plot should now show values like
1293 they are commonly used.
1294
1295 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1296 (a powerlaw with cutoff didn't work before)
1297
1298
1299
1300 *** Version 0.9.4.2 (2005/10/01)
1301
1302 - general: added new tutorial macro macros/tutorials/threshold.C:
1303 how to calculate the threshold
1304
1305 - general: added a new game. Start it from the interpreter with
1306 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1307 and MagicReversi)
1308
1309 - general: neighbor pixels in MGeoms are now sorted clockwise
1310
1311 - merpp: made aware of new format 20050829-0
1312
1313 - callisto: New scale factors from muon analysis, stored in new
1314 resource file resources/calibration.rc
1315
1316 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1317 the eventloop if something went wrong. This is necessary for the
1318 automatic processing
1319
1320 - callisto: Implemented a new treatment for the time information
1321 developed by S.Ruegamer, this should give much better response than
1322 the old very primitive algorithm. This is especially important
1323 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1324 treatment was buggy! As neighbor pixels to interpolate the
1325 arrival times always the pixels 0 to 5 were taken)
1326
1327 - callisto: In addition to the new treatment of arrival times the
1328 decision of the treatment whether a pixel contains shower
1329 information or not is used to improve the signal interpolation
1330 further. Previously interpolated pixels showed a non-zero signal
1331 do the peak searching signal extractors. Having a signal pixel
1332 beside raised the signal above the cleaning level. Thus the
1333 pixel survived cleaning to often but with a too low mean signal.
1334 By replacing empty pixels with a gaus (mean and rms from the
1335 corresponding Area entries in MPedPhotCam) this effect can
1336 be supressed.
1337
1338 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1339 got lost when the events were stored by the calibration... fixed.
1340 (This was no problem for normal image cleaning because the pixel
1341 content was artificially set to 0 not surviving standard cleaning
1342 algorithm)
1343
1344 - callisto: Fixed a bug which caused the random and peak-search pedestal
1345 extracted with an extractor to be exchanged for the first (roughly)
1346 500 events (*Extractor and *ExtractorRndm).
1347 (They were simply exchanged in callisto.cc) This bug might have been
1348 introduced in Mars 0.9.4 when the order of calculation of the two
1349 types of pedestal in callisto got exchanged. The bug only effects
1350 the first seconds of data of each sequence.
1351
1352 - star: Taking the arrival time of Muons into account the calculation
1353 of the parameters could be made independant of the noise
1354 (pedestal rms). The dependance was due to the bias of the peak search
1355 extractor. Now only a ZA dependamcy is left which is not yet fully
1356 understood.
1357
1358 - ganymed: The sequences were still not sorted correctly in any case,
1359 because they were sorted by the full qualified path name. Now they
1360 are sorted by their sequence number.
1361
1362 - ganymed: new values for the spark-event-cut
1363
1364 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1365
1366
1367
1368 *** Version 0.9.4.1 (2005/08/18)
1369
1370 - callisto: fixed some problems with the calibration in case of
1371 inteleaved events. Therefor the final and some intermediate
1372 fits are skipped which would take place on partly filled #
1373 histograms and gave wrong results or failed completely.
1374
1375 - callisto: If the intermediate finalization of the histograms
1376 calculating the mean charge of the calibration signal fails
1377 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1378
1379 - ganymed: Fixed some bugs which caused problems in On-only mode.
1380 Still the false source plot doesn't give reasonable results.
1381
1382
1383
1384 *** Version 0.9.4 (2005/08/05)
1385
1386 - general: Fixed the ZA binning. It did not correctly fit the
1387 MC binning
1388
1389 - general: Added a class to correct for the missfocussing in
1390 April (MSrcPosCorrect)
1391
1392 - general: Random Forest energy estimator should now work properly
1393
1394 - general: MHCamera now displays the profiles in deg instead of mm
1395
1396 - general: MH::SetPalette offers a lot of new palettes
1397
1398 - general: MHillas - the case of CorrXY==0 is now handled properly
1399
1400 - general: implemented the possibility to change the line and
1401 marker style of a sky-grid drawn by MAstroCatalog
1402
1403 - general: Runs in sequences and datasets are now automatically
1404 ordered (it is assumed that the order of their filenames correctly
1405 represents the order of observations) to ensure correct reading
1406 of the subsystem data
1407
1408 - general: Runs cannot be added to a sequence twice anymore. Also
1409 Sequences cannot be added twice anymore to a dataset.
1410
1411 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1412 It gave wrong results by 1./2pi
1413
1414 - showplot: got a new option to start a root interpreter, too
1415
1416 - mars: now displays a rough estimate of Disp and the third moment
1417
1418 - mars: now displays the event time MTime if available
1419
1420 - mars: show muon parameters graphically
1421
1422 - mars: now the file to open can be given as commandline
1423 argument
1424
1425 - merpp: Added support for new arehucas version >= 200507190
1426 implementing values for three temperature sensors in the
1427 counting house (MCameraAUX) and the name of the HV settings file
1428 (MCameraHV).
1429
1430 - merrp: Also fixed some problems with wrong versions numbers stated
1431 by arehucas and implemented some fixed for old versions (<200407070)
1432
1433 - callisto: MCalibrationHiLoCam can now be printed from its context
1434 menu, eg in the TBrowser
1435
1436 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1437 - 1.39 (MExtractTimeAndChargeSpline)
1438 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1439 This is important mainly for timing studies.
1440
1441 - callisto: Changed limits in MHCalibrationChargeCalc from
1442 - -100.125 to -98 (fgChargeHiGainFirst)
1443 - 1899.875 to 1902. (fgChargeHiGainLast)
1444 - -100.25 to -99 (fgChargeLoGainFirst)
1445 - 899.75 to 901. (fgChargeLoGainLast)
1446 Introduced new limits:
1447 - fgNumLoGainBlackoutLimit: 0.05
1448 - fgLoGainBlackoutLimit: 3.5
1449 - fgLoGainPickupLimit: 3.5
1450
1451 - callisto: The handling of automatic weights for the digital filter
1452 has been improved. There are now new calibration weights special
1453 for Monte Carlo calibrations.
1454
1455 - callisto: Updated Muon scale with latest results (1% difference
1456 for most data, 5% for Mar/Apr'05)
1457
1458 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1459 was saturated and the blackout-events in the low-gain exceed the
1460 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1461 This excludes those pixels which have a saturating high-gain
1462 channel, but the low-gain switch does not switch often enough
1463 to make the distribution reliable.
1464
1465 - callisto: fix a bug counting the number of saturated events. Up to now,
1466 the number of saturated slices was counted (which is one for a not too
1467 high number), but for some (pathological) pixels, many more slices
1468 saturated and produced wrong limits.
1469
1470 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1471 + MCalibrationRelTimeCam.CheckFitResults: Yes
1472 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1473 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1474 + MCalibrationRelTimeCam.CheckOscillations: Yes
1475
1476 - callisto: introduce max. number of events for intercalibration,
1477 the rest gets skipped. Default: 4096
1478 The calibration causes too many un-reliable pixels if more
1479 than about 5000 events are treated (@500 Hz) because of the
1480 mode hopping of the VCSels. However, in the past, some
1481 calibration runs have been taken (erroneously) with more
1482 than 5000 events, especially the intensity scans where
1483 a good precision is needed.
1484
1485 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1486 photo-electrons for the spline extractor by 1-2% (correctly).
1487
1488 - callisto: The intercalibration is now done using a full f-factor
1489 method instead of a simple update. This makes things slower but
1490 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1491 changes.
1492
1493 - callisto: MPedestalY3 now uses the same extraction range as the data
1494 as calculated by MPedestalY2
1495
1496 - callisto: A check of the fraction of allowed unsuitable (10%) and
1497 unreliable (30%) pixels has been addded when the conversion is
1498 calculated from interleaved events
1499
1500 - star: fixed a bug which caused MEffectiveOnTime containers not to
1501 be written. In the worst case they were skipped almost all, in the
1502 best case they were all ok. It depends on how often the new value
1503 was assigned just with an event which was skipped later by another
1504 task
1505
1506 - star: new histograms MHPointing and MHRate
1507
1508 - star: New tab (Currents) displaying the time evolution of the mean
1509 DC currents
1510
1511 - star: New tab (MeanRms) displaying the time volution of the mean
1512 Pedestal Rms
1513
1514 - star: Output now contains MReportStarguider
1515
1516 - star: Improved muon analysis. Due to the absense of a constant
1517 for the gaus fit for arc width and the fact that the arcwidth
1518 plot was a histogram instead of a profile the resulting psf
1519 became pedestal rms dependant
1520
1521 - ganymed: added new plot (MHPhi) for wobble mode as described in
1522 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1523
1524 - ganymed: corrects now (correctly?) for the misspointing in
1525 May/April 05
1526
1527 - ganymed: Two new default templates for ganymed.rc are avilable:
1528 ganymed_onoff.rc and ganymed_wobble.rc
1529
1530 - ganymed: The first version of MFMagicCuts has been released
1531
1532 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1533
1534 - ganymed, sponde: There are two new options to determin the number
1535 of bins for the signal region (NumBinsSignal) and the number of
1536 total bins (NumBinsTotal) in the MHThetaSq histogram
1537
1538 - ganymed: optimized palettes for MHDisp
1539
1540 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1541 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1542 sqrt(2) to large
1543
1544 - ganymed: The false source plot (MHDisp) is now based on Disp
1545 and a background model determined in the first loop is
1546 subtracted
1547
1548 - ganymed: MFMagicCuts are now available in the cvs. The correct
1549 solution for the disp ambiguity problem is now calculated using
1550 the third moment. The third moment cut therefor is skipped.
1551
1552 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1553 already determined by the third moment along the major axis and
1554 so its actual sign is aligned along the major axis of the shower.
1555
1556 - ganymed: If starguider data is available it is taken into account
1557 when calculating the source position. This is especially important
1558 for wobble data at high zenith angles and culmination data.
1559
1560 - ganymed: If available the starguider data is taken into account as
1561 good as it is possible without a starguider calibration. To switch
1562 it off add
1563 MPointingDevCalc.MaxAbsDev: -1
1564 to your ganymed.rc
1565
1566 - sponde: the zenith angle distribution is now weighted instead of
1567 choosen by default. This gurantees higher statistics in the highest
1568 and lowest energy bins. To switch this behaviour off use...
1569
1570 - sponde: now automatically displays the energy threshold
1571
1572
1573
1574 *** Version 0.9.3 (2005/06/03)
1575
1576 - general: MMcEvt now derived from MMcEvtBasic which should
1577 have no influence on compatibility with older camera files
1578
1579 - general: Implemented a new option to MReadReports which allows
1580 to force reading of the first event of some trees (eg. Drive-tree)
1581 before any other tree.
1582
1583 - general: Made a fix to MPointingPosCalc which assumes that the
1584 run-type is real-data if Process is called before ReInit, such
1585 that also the very first Drive-events in a run are treated
1586 correctly.
1587
1588 - shoplot now displays the filename in the title bar of the window
1589
1590 - merpp: new options: --auto-time-start --auto-time-stop which
1591 allow to cut updating with slow-control at the start- or
1592 (previousle --auto-time only allowed: and) stop-time of
1593 the run stored in the runheader.
1594
1595 - callisto: changed default of fgFallTimeHiGain in
1596 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1597 already set as default in callisto_Dec04Jan05.rc
1598
1599 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1600 now changes the filename for new weights automatically for
1601 cosmics, MC and for different calibration colors.
1602
1603 - callisto: a problem with the order of some code cause the
1604 name of the weights file in MPedestalY2 to be ignored.
1605 Wrongly the calibration_UV weights were used instead
1606 of the cosmics weights set in callisto.rc.
1607
1608 - callisto: should allow ct1 pulser data when the color is
1609 explicitly set also for pretty new runs
1610
1611 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1612 to introduce an additional scale factor (should be around 1)
1613 to adapt for slight deviations in different extractors from
1614 the MC calibration. For MC calibrations the scale factor
1615 is fixed to 1
1616
1617 - callisto: MFCosmics should handle very high signals a bit
1618 more accurate now
1619
1620 - callisto: when calculating the mean pedestal rms for different
1621 pixel sizes or sectors also kUnsuitableEvt is now taken into
1622 account - not only kUnsuitableRun
1623
1624 - callisto: '-raw' option is now the default
1625
1626 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1627 This has the advantage that mean values in the calibration (eg
1628 arrival times) are calculated more accuratly.
1629
1630 - callisto: In the resource file callisto_Dec04Jan05.rc
1631 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1632
1633 - callisto: new Hi-/Lo-Gain intercalibration constants
1634 hilocalib_sp1.root and hilocalib_sp1_mc.root
1635
1636 - callisto: changed default for MJPedestalY2.MaxEvents
1637 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1638
1639 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1640 has changed from 9.0 to 6.0. This is necessary to exclude two very
1641 ringing pixels in September which - when kept - destroy the image
1642 cleaning around them (Markus G.)
1643
1644 - callisto: (!) The Muon analysis of all data taken so far has
1645 suggested that different extractors give slightly different
1646 absolute results after calibration, due to there different
1647 handling of the calibration- and cosmics pulse shape. Although
1648 the over all calibration seems to be a bit to pesimistic (or
1649 the MC seems to be a little bit - 3-5% - too much attenuated).
1650 There for correction factors have been introduced which correct
1651 the calibration constants by
1652 0.956937799 for Digital Filter (callisto.rc)
1653 and
1654 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1655 calibration. The main advantage is, that both data types can
1656 be easily analysed together and compared to the same MC sample.
1657 The factors are choosen such, that the reference is now a
1658 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1659
1660 - star: fixed a bug which caused the first bin of the histograms
1661 vs time to disapear in PostProcess. This gave wrong results
1662 on the screen. The output and all following programs not
1663 directly accessing the histograms haven't been affected
1664
1665 - star, ganymed: Made sure that always the first Drive-tree event
1666 is read and Processed before the first data event was read.
1667
1668 - ganymed: implemented the possibility to replace the standard
1669 false source plot with a different one. For example: If
1670 you want to use a Disp based FS plot use the resource:
1671 NameHistFS: MHDisp
1672 For details about the requirements of these plots look
1673 at the corresponding classes
1674
1675 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1676 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1677 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1678 case MAlphaFitter is setup correctly. For On-Only optimization
1679 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1680 RunOn() instead of Run(). For energy estimation MJOptimize
1681 has been replaced by MJOptimizeEnergy
1682
1683 - sponde: The input MC spectrum can now be weighted to fake a
1684 different spectrum. This is done via MMcSpectrumWeight. For
1685 more details see the class description and sponde.rc
1686
1687 - sponde: The paremeter comparsion plots are not scaled by
1688 their entries anymore. Instead the MC plot is scaled by using
1689 the result spectrum of the analysis. If the input MC spectrum
1690 and the result spectrum has different slopes the absolut
1691 normalization is normally wrong.
1692
1693
1694
1695 *** Version 0.9.2 (2005/05/20)
1696
1697 - general: Changed the default paths for calibrated data and image
1698 files. (The implemented access to these files doesn't yet exist)
1699
1700 - general: support for MRunIter has been removed from the job classes
1701 (use the setter functions of MSeqeunce instead)
1702
1703 - general: ProcessFile has been renamed to Process in all job classes,
1704 because ProcessFile is missleading
1705
1706 - general: The storage of the palette in MHCamera is now possible
1707
1708 - general: new bits describing unsuitable and unreliable pixels have
1709 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1710 kDeadPedestalRms, kFluctuatingArrivalTimes
1711
1712 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1713 versions newer than V200404070
1714
1715 - general: support for cc file versions newer than V200504130. Added
1716 support for active loads (MCameraActiveLoad) and central pixel
1717 (MCameraCentralPixel)
1718
1719 - general: added new histograms for image parameters versus size
1720 (MHVsSize)
1721
1722 - general: The eventloop now automatically calls PrintStatistics
1723
1724 - Status Display: Improved support for printing:
1725 + A default can now be set in .rootrc (for more details see
1726 MStatusDisplay::PrintPS)
1727 + A print dialog is opened so that printer and command line
1728 can be canged
1729
1730 - showlog: improved such that it handles different verbosity levels
1731 more accurate now. This mean you can suppress output when
1732 using showlog.
1733
1734 - showplot: improved
1735 + The new graphics formats have been implemented
1736 (pdf, svg, png, jpg and xpm)
1737 + Implemented an interface for printing. Because you can change
1738 the printing command from the command line you can use all
1739 the nice postscript tool. To print a booklet for example call:
1740 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1741 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1742 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1743
1744 - callisto: fixed a bug in the recognition of the calibration bit
1745 pattern. Concerns only intensity calibration. (The strength of the
1746 intensity has been updated in some cases)
1747
1748 - callisto: add a filter against PIN Diode events when running over
1749 calibration runs since some of the recent calibration runs have
1750 been taken with Pin Diode.
1751
1752 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1753 39943, 44833 in the calibration (MCalibColorSet)
1754
1755 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1756 been set to 1e-18 in callisto_Dec04_Jan05.rc
1757
1758 - callisto: in callisto_Dec04Jan05.rc: set value for
1759 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1760 statistics for the calculation of the mean pulse time
1761 of the cosmisc
1762
1763 - callisto: the charge limit in the calibration has been raised
1764 from 2.5 to 4.5
1765
1766 - callisto: new setup read from callisto.rc
1767 + MCalibCalcFromPast.fNumEventsDump
1768 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1769 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1770
1771 - callisto: MExtractTimeAndChargeSpline extractor:
1772 + The integration ranges were shifted by 0.2 FADC slices to the right.
1773 + unreliable handling of floating point values caused different
1774 results on different platform or with different compiler options:
1775 The new algorithm is numerically exact and more accurate because
1776 it doesn't calculate the integration position by multiple times
1777 adding the step-size (which results in numerical uncertanties
1778 exspecially if multiplied with large numbers)
1779 + A lot of fixes have been introduced which effects integrating the
1780 spline at the edges of the valid range. In this case any memory
1781 was randomly accessed. This behaviour can be tested replacing
1782 all MArrayF by TArrayF which perform a range check (but of course
1783 they are a lot slower)
1784 ! No result obtained with the Spline before can be trusted! Due to
1785 random memory access it might by completely random!
1786
1787 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1788 + extraction range in the high gain to 4.
1789 + weights file to cosmics_weights46.dat
1790
1791 - callisto:
1792 + introduce the check for fluctuating arrival times.
1793 + set charge limit to from 2.5 to 4.5
1794 + introduce asymmetric exclusion due to "deviating number of phes":
1795 Default: -9.0 +4.5
1796 + make deviating number of phes unsuitable (see David's findings).
1797
1798 - callisto: fixed the display of unsuitable pixels. The old change
1799 to a real profile in MHCamera broke it.
1800
1801 - callisto: The cosmics filter is used in MJCalibration now
1802 independant of the pulser color (formaly it was used only for
1803 CT1-pulser data). The threshold of number of max empty pixels
1804 has been raised from 2% to 5% in MJCalibration. The maximum
1805 fraction of rejected event is 50% otherwise the calibration has
1806 failed. The filter now ignores unsuitable pixels.
1807 Setup the filter from callisto.rc using "ContCosmics"
1808 (see MFCosmics::ReadEnv)
1809
1810 - callisto: changed default for fgOffsetFromLogain back
1811 from -2.8 to -1.8 in digital filter.
1812
1813 - callisto: for the common extractors
1814 + MExtractFixedWindow
1815 * MExtractTimeAndChargeSlidingWindow
1816 * MExtractTimeAndChargeSpline
1817 * MExtractTimeAndChargeDigitalFilter
1818 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1819 and fResolutionPerPheLoGain
1820
1821 - callisto: Updated the hi-/lo-gain intercalibration constants
1822 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1823 hilocalib_df6.root
1824
1825 - callisto: The default lo-gain extraction window for the
1826 MExtractTimeAndChargeSlidingWindow extractor has been increased
1827 from 6 to 8 to take the stretch of the pusle into account
1828
1829 - callisto (!!!): fixed an important bug in the setting of the
1830 incoming pedestal pointer to the signal extractor extracting
1831 pedestals. This bug caused the pedestals not to be subtracted
1832 correctly in the calibration afterwards. The effect was about 10%
1833 too high conversion factors for the digital filter and the spline
1834 and more than 40% for the sliding window.
1835 The bug existed since end of February! (Markus G.)
1836
1837 - star: added muon support to star. A new tab "MHMuonPar" is
1838 displayed. The lower right plot is an estimate of the point spread
1839 function. A reference value is displayed. To get the real PSF
1840 you must compare with MC. The setup for the muon analysis
1841 is done in star.rc. More informations can be found in
1842 MHSingleMuon and MHCalibParCalc
1843
1844 - star: The weather data is now displayed in star
1845
1846 - star: MEventRateCalc handles the calculation of the event rate more
1847 accurate now in case of the start of a new run inside a sequence
1848
1849 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1850 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1851 changed only minimally
1852
1853 - ganymed: (MJCut and MJOptimize) now displayes the number of
1854 excess events versus size. The energy estimation is done in
1855 MJSpectrum (sponde)
1856
1857 - ganymed: got support for using other variables than Alpha, eg. Theta.
1858 Therefor you need a class deriving from MHAlpha which supports
1859 this variable (one is already existing: MHTheta, which is now the
1860 default in ganymed). It is setup through ganymed.rc
1861
1862 - added a full featured spectrum program (sponde) which reads
1863 ganymed output and monte carlos and compiles a spectrum
1864
1865
1866
1867 *** Version 0.9.1 (2005/04/14)
1868
1869 - Fix bug on the arrival time reconstruction when using Digital
1870 Filter (in some marginal cases (10%) times were reconstructed shifted
1871 by 0.2 slices)
1872
1873 - all executables now return 2 where in previous versions -1 has
1874 been returned (gave problems with shell-scripts)
1875
1876 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1877 also done with a intercalibration input file
1878
1879 - a bug in the time fine adjustment of the digital filter has been fixed
1880
1881 - a lot of small fixes to calling TPad::Divide with a margin==0
1882
1883 - MStatusDisplay now shows the memory usage
1884
1885 - added a memory leak statistic after the eventloop
1886
1887 - MHadronness replaced by MParameterD
1888
1889 - MEnergyEst replaced by MParameterD
1890
1891 - wobble mode can now be switched on from the data-set
1892
1893 - switched on bad pixel detection for a pedestal level
1894 which is more than 5 times the variance
1895
1896 - Fixed default paths to be correct for the new data center
1897
1898 - Fixed handling of drive data. The pointing position in now
1899 copied to MPointingPos inside star for real and MC events
1900
1901 - made sure, that the sequences in a dataset are sorted by
1902 their number to ensure the correct synchronization
1903
1904 - added all resource files necessary to handle spline extraction
1905 of signal for the late 2004 and the early 2005 data
1906
1907 - update the reference lines for the december data
1908
1909 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1910 This is important for the Dec. and Jan. data where the calibration
1911 pulse position changes much.
1912
1913 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1914 filter. This corrects only an defective extraction of the MC at
1915 low-gain signals lower than 90 phes.
1916
1917 - fixed some slowdown in calibrating data with interleaved events from
1918 Jan and Dec. As a workaround made the pretty palette the default.
1919 The inverse Deep Blue Sea has a bug which slows down long calibration
1920 runs a lot.
1921
1922 - implemented new values from new starguider report as defined
1923 in TDAS00-07 V7.1 (eg SkyBrighness)
1924
1925 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1926 in starguider report (If you merpp the same reports with this version
1927 you'll get the correct units (arcmin) but a different result
1928 than with old versions (wrong units))
1929
1930 - Now the status display can also write PNG, JPEG and XPM (other file
1931 formats are still unsupported by root)
1932
1933 - added a lot of scripts and macros in directory datacenter used
1934 for automatic processing
1935
1936
1937
1938 *** Version 0.9 (2005/03/23)
1939
1940 - Calibration is now done autmatically into photo-electrons like
1941 decided by the Collaboration Board
1942
1943 - Reference lines in the display can be read from resource file
1944
1945 - Interlaced calibration events can be handled by callisto
1946
1947 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1948 and applied in callisto.
1949
1950 - class MJCalibTest can be called by callisto
1951
1952 - callisto can now run with three data types: rawdata, rootdata, MC
1953
1954 - added two classes mreport/MReportStarguider.cc and
1955 mreport/MReportStarguider.h for implementing starguider-data
1956
1957 - the output of merpp-update now contains starguider information:
1958 MReportStarguider and MTimeStarguider
1959
1960 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1961 values were lower than they should. This was more visible for high
1962 energy (Size) events.
1963
1964 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1965
1966 - added a new loop to callisto to support the correct extraction of
1967 the pedestal and pedestal rms through the signal extractor
1968
1969 - added class to perform fourier tranformation of a hexagonal structure
1970 (MHexagonalFT)
1971
1972 - added class to perform fourier tranformation of a hexagonal structure
1973 in a tasklist (MHexagonalFTCalc) example: hft.C
1974
1975 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1976 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1977 small pixels, example: extendcam.C
1978
1979 - added possibility to write data to memory (TTree) using MWriteRootFile
1980
1981 - added possibility to read a TTree stored only in memory by MReadTree
1982
1983 - new classes to deal with the interleaved calibration events:
1984 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1985
1986 - implemented filters to callisto to skip calibration events
1987
1988 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1989 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1990 the slices by statistics
1991 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1992 signal extractor without randomization
1993 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1994 with the signal extractor with randomization (extraction window is
1995 randomly fixed)
1996 The three kind of pedestal is not yet implemented (for speed reasons) as
1997 long as nobody really needs it:
1998 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1999 extracted with the signal extractor with randomization
2000
2001 - callisto now finds the pulse position in the data automatically
2002
2003 - implemented data reduction in calibrated data by reducing the precision
2004 of the stored floating point values (pedestal, rms and signal) to
2005 roughly 0.5%
2006
2007 - fixed showplot to make file format conversion (eg. converting a
2008 status display stored in a root file into a postscript file) in
2009 batch mode possible:
2010 showplot -b --save-as-ps[=outfile.ps] infile.root
2011
2012 - Allow class names as part of filter rules, eg
2013 (MFSupercuts) && (MHillas.fSize>100)
2014
2015 - fixed a lot of stuff to allow all programs to process MonteCarlo
2016 camera files.
2017
2018 - enhanced possibility to debug reading of resource file
2019
2020 - MDataChain should handle priorities of operator more
2021 accurate now
2022
2023 - completely revised the container in which the signal is stored
2024 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2025 * the new implementation is faster and
2026 * needs less storage space
2027
2028 - FIRST version which can process Monte Carlos through the
2029 whole chain of programs (callisto, star, etc)
2030
2031 - implemented new image parameters for the border length of
2032 the shower image (MNewImagePar2)
2033
2034 - implemented wobble-mode in ganymed
2035
2036 - new class (MJOptimize) taking care of all optimization processes
2037
2038
2039
2040 *** Version 0.8.6 (2004/10/05)
2041
2042 - New combined signal and time extractor
2043 MExtractTimeAndChargeDigitalFilter
2044
2045 - The Report for the trigger section in the CC run summary has been
2046 updated, and now the IPRs (Individual Pixel Rates) are available.
2047
2048 - new macros for database interaction: filldotrun.C, filldotrbk.C
2049
2050 - added new program which can convert colored output which was redirected
2051 into a file back into colored text (for example to display it with
2052 more): showlog
2053
2054 - added new program to display an MStatusArray of plots (stored with
2055 MStatusDisplay) from a file: showplot
2056
2057 - Added support for Sequences (MSequence). Sequences are blocks of run
2058 files containing the same calibration and belonging to the same
2059 source
2060
2061 - Added a new task (MTaskEnv) which can be used in setup files to switch
2062 between different tasks (for example to choose a signal extractor)
2063
2064 - Implemented automatic file splitting in MWriteRootFile
2065
2066 - After image cleaning an island index is assigned to all used pixels.
2067 The index corresponds to the order of the islands in size.
2068
2069 - added a cleaning which takes signal height _and_ arrival time into
2070 account: probability cleaning (for more details see MImgCleanStd)
2071
2072 - added a cleaning which takes takes the absolute number of photons
2073 times the area ratio as cleaning level
2074 (for more details see MImgCleanStd)
2075
2076 - Changed calculation of image parameters such, that it can be done
2077 for all used pixels or the pixels with a defined island index only
2078
2079 - implemented new image parameters displaying the number of islands,
2080 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2081
2082 - event display in executable changed to support also calibrated files
2083 (done with MJCalibrateSignal)
2084
2085 - added program doing the calibration and the signal extraction
2086 and signal calibration: callisto Most part of the setup is done
2087 by a resource file: callisto.rc
2088
2089 - implemented support for pixels with negative IDs (Raw file format
2090 version 4)
2091
2092 - implemented an new option in merpp (--auto-time) to get the time
2093 range for cc and/or caco data from the run header of the raw data
2094
2095 - New star-program (star and MJStar). Taking calibrated data from
2096 callisto/MJCalibrateSignal as input. The setup is done through
2097 a resource file: star.rc
2098
2099 - Added possibility to setup the eventloop in the mars-executable
2100 Camera Display by a resource file: mars.rc
2101
2102 - The the mars-executable Camera Display can now also read
2103 calibrated data files written by callisto/MJCalibrateSignal
2104
2105 - Added a new class which can calculate the source position in
2106 the camera from a pointing model known to be correct and
2107 the pointing model used for observations (MSrcPosFromModel)
2108
2109 - added a new version of the class calculating the effective on-time
2110 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2111 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2112 MHTimeDiffTheta.
2113
2114 - added the possibility to count how often a signal is above (or
2115 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2116 can replace MHTriggerLvl0)
2117
2118 - added ore convinient ways to set the axis-titles of your histograms
2119 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2120 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2121
2122
2123
2124 *** Version 0.8.5 (2004/08/06)
2125
2126 - new Signal Extractors: MExtractFixedWindowSpline
2127 and MExtractAmplitudeSpline
2128
2129 - implementes interleave in merpp to be able to merpp parts of a file
2130
2131 - implemented force-functionality to merpp
2132
2133 - star display to display star catalogs (MAstroCatalog)
2134
2135 - star display to 'mirror' stars to the camera (MAstroCamera)
2136
2137 - implemented a new cleaning option which allows cleaning scaled with
2138 the real ratio of the rms depending on the pixel size, not only the
2139 square root of the pixelsize (MImgCleanStd, MCameraData)
2140
2141 - removed obsolete MBlind* classes
2142
2143 - Signal extractor taking the AB flag into account implemented (this makes
2144 an odd number of slices for signal extraction possible
2145 (MExtractSignalABcorr)
2146
2147 - implemented a class extracting the pedestal from the raw-data (events)
2148 itself using empty lo-gain (MpedCalcFromLoGain)
2149
2150 - Added mean values to MPedPhotCam
2151
2152 - Added Makefile for Darwin (this OS is NOT officially supported!)
2153
2154
2155
2156 *** Version 0.8.4 (2004/04/19)
2157
2158 - new fast arrival time extractor using cubic splines:
2159 MExtractTimeFastSpline
2160
2161 - implementes multi-argument support in MDataChain
2162 ("pow(a, b)")
2163
2164 - implemented double reference support in MDataChain
2165 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2166
2167 - added support in MF for expressiond like
2168 "MHillas.fWidth<2*<MHillas.fLength"
2169
2170 - MDataChain is now able to support variables like [0], [1], ...
2171 which can be used in fit functions as parameters. The interface
2172 is implemented through the new virtual function
2173 MParContainer::SetVariables
2174
2175 - added new class MArrivalTimeCam/MArrivalTimePix:
2176 Storage containers to hold the ArrivalTime of the camera/pixel
2177
2178 - added new classes for the calibration of relative arrival times:
2179 MCalibrationRelTimePix and MCalibrationRelTimeCam
2180
2181 - added new classes to extract the signal of the blind pixel and the
2182 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2183
2184 - added new classes for the bad-pixels treatment (MBadPixels*)
2185 which are more powerfull than the old ones (MBlindPixel*)
2186 and will replace them.
2187
2188 - added filter against cosmics: MFCosmics
2189
2190 - added new class MArrivalTimeCalc2:
2191 Calculates the arrival time as the signal weighted mean of the time
2192 slices in the maximum window
2193
2194 - added a new macro call pointspreadfucntion.C that fits with a 2D
2195 gaussian the DC spot for an star. It gives you the RMS of
2196 the PSF and the center of the star, very useful for misspointing
2197 studies.
2198
2199 - added support for multi-telescope camera files. Added classes
2200 MStereoCalc and MStereoPar, classes to calculate and store shower
2201 parameters calculated from the data of two telescopes, for the MC
2202 studies regarding the MAGIC clone.
2203
2204 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2205 MC data calibrated in photons instead of ADC counts.
2206
2207 - added three macros to show the calibration and analysis chain of
2208 MC data. The macro starmc.C does both calibration and analysis, producing
2209 an output containing Hillas parameters for each event. The macro
2210 mccalibrate.C does just the calibration and writes out a file containing
2211 pixel information in photons instead of FADC data. The macro starmc2.C
2212 reads in such a file and produces an output with Hillas parameters.
2213
2214 - added MPedPhotCalc to compute pedestals in units of photons, see
2215 macro pedphotcalc.C
2216
2217 - added all class to perform the calibration, see macro calibration.C
2218
2219 - added class MFFT to perform Fast Fourier Transforms
2220
2221 - added class MSimulatedAnnealing to perform simulated annealing
2222 minimizations
2223
2224 - added new macro bootcampstandardanalysis.C which holds the skeleton
2225 of the analysis chain discussed in the december bootcamp.
2226
2227 - added support for DAQ raw data file format V2
2228
2229 - implemented an arbitrary time stamp for the events from raw-data
2230 files with file version<3. It is calculated from the run number,
2231 the date of start and the FADC clock tick from the first module
2232
2233 - implemented the correct decoding of the event time-stamp
2234 coming from the DAQ for raw-data files with file-version>2
2235
2236 - added a new classes storing the pedestals in units of photons:
2237 MPedPhotPix, MPedPhotCam
2238
2239 - added support for DC current files from the camera control
2240
2241 - added support for start- and stop-time when merpping report files
2242
2243 - added MReportCC storing the weather data from the CC-REPORT
2244
2245 - added class to fill trainings and test matrices (MTFillMatrix)
2246
2247 - added a filter performing a software trigger (MFSoftwareTrigger)
2248
2249 - Added classes to perform parts of the standard analysis (Jobs):
2250 + MJPedestals
2251 + MJCalibration
2252 + MJExtractSignal
2253 Note: All of them are preliminary!
2254
2255 - Added Iterator to iterate over files giving only the run-number
2256
2257 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2258 the evolution of a sector vs time
2259
2260
2261
2262 *** Version 0.8.3 (2003/12/05)
2263
2264 - adapted Random Forest classes to allow the use with MC
2265 multi-telescope files which can be produced with the coming
2266 camera version 0.7.
2267
2268 - added classes to read and interprete central control report files
2269 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2270
2271 - enhanced merpp (the executable) to support .raw and .rep files.
2272
2273 - added classes for light calibration (MCalibration* and
2274 MHCalibration*) by Markus Gaug. Further work has to be and will
2275 be done soon.
2276
2277 - Added a preliminary 'synchronizer' (MReadReports) which will
2278 replace MReadMarsFile as soon as it is finished.
2279
2280 - Added a tutorial macro demonstrating how report files are merpped
2281 and how they can be read from the root file in the correct order
2282 of time (readrep.C)
2283
2284 - Added a generalized histogram (similar to MH3) called MVsTime
2285 which allows to plot variables (or rules - MDataChain - of
2286 variables) vs time. For an example have a look at tempvstime.C.
2287
2288 - Changed the name of the event trees:
2289 + Events --> Events
2290 + PedEvents --> Pedestals
2291 + CalEvents --> Calibration
2292
2293 - changed name of MTime in the event trees from MRawEvtTime to MTime
2294
2295 - added displaying the sector indices to the mars event display
2296
2297 - Magic Online Analysis (MOnA) implemented in a first version
2298 (see mona.cc, MOnlineDump and MOnlineDisplay)
2299
2300 - added classes to calculate event rate
2301 (preliminary: MEventRateCalc, MEventRate)
2302
2303 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2304
2305 - added classes dealing with the telescope pointing position (MPointing*)
2306
2307 - implemented the 'final' Mars time stamp based on some experiences with
2308 the new 'Synchonizer'
2309
2310
2311
2312 *** Version 0.8.2 (2003/11/10)
2313
2314 - accelerated standard analysis by a factor of 6-8 ...
2315 + doing precalculations in MGeomCam for the pixel area ratio
2316 + creating a look up table for the single pixels in MCerPhotEvt
2317
2318 - added task to calculates weights in case you want to 'change'
2319 the energy spectrum of a monte carlo file
2320 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2321
2322 - added a new executable star which implements the
2323 star.C macro as precompiled executable. Currently a flexible
2324 setup is not possible, but a 'input card' setup will follow.
2325
2326 - Starting to implement Multi-Telescope-Support based on the
2327 upcomming camera version 0.7. The base for a general support
2328 is implemented and the star-functionality is proven to work.
2329
2330 - Replaced Event-Display in and Camera-Display in the Mars GUI
2331 executable by a more convinient display base on MStatusDisplay.
2332
2333 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2334
2335
2336
2337 *** Version 0.8.1 (2003/10/20)
2338
2339 - added signal subtraction for pure on data by means of fitting
2340 the background in the off region or by performing a combined
2341 signal/background fit. Provides necessary histograms for
2342 obtaining energy spectra and a light curve.
2343
2344 - added classes to perform and study the selection of the
2345 2nd Level Trigger on MC data (example in triglvl2.C macro)
2346
2347 - added pedestal calculation
2348
2349 - implemented "democratic cleaning" (tail cut value proportional
2350 to pixel area) according to Wolfgang's suggestion.
2351
2352 - added Sigmabar treatment (calculation and basic histogramming)
2353
2354 - added basic routines to apply padding
2355
2356 - added first implementation of MARS-based source visibility plotter
2357 (needs to be linked against slalib, preliminary version)
2358
2359 - enhanced functionality of data chains: random numbers, conversion
2360 functions and access to MHMatrix objects
2361
2362 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2363 numbers under certain circumstances (runs with 0 events included)
2364
2365 - fixed a bug in the general filter MF (didn't work on some systems
2366 at all)
2367
2368 - fixed a bug in chaining files, which caused the analysis to crash or
2369 ignore files
2370
2371 - implemented more geometry classes describing the parameters used
2372 to simulate the PMT camera
2373
2374 - added new Monte Carlo classes containing the setup of the different
2375 programs in the MC chain.
2376
2377 - added a (preliminary) general task to evaluate chi-square of a given
2378 parameter in an eventloop.
2379
2380 - first implementation of a container describing the observatory
2381 location (Long, Lat, etc)
2382
2383 - added Random Forest - method for g/h-separation
2384
2385 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2386 (this means, that it is compiling, but not yet fully tested)
2387
2388 - added a new status display which can show the present status
2389 of histograms while an eventloop is running (MStatusDisplay,
2390 an example can be found at status.C)
2391
2392 - reorganized directories:
2393 classes describing the image --> mimage
2394 classes containing Monte Carlo Histograms --> mhistmc
2395 classes for Random Forest method --> mranforest
2396
2397 - added (event-)weights to fill histograms
2398
2399 - colors in logging output to screen
2400
2401 - changes to the Image Parameter declaration:
2402 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2403 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2404 + MHillasExt now derives from MParContainer instead of MHillas
2405 --> Files written with the old definition are more or less unreadable
2406
2407 - reading of reflector files
2408
2409 - display data from reflector files in the camera
2410
2411 - implemented currents (and display them in the camera)
2412
2413 - logarithmic scale in camera
2414
2415 - added class to iterate through directory contents (MDirIter)
2416
2417
2418
2419 *** Version 0.8 (2002/11/18)
2420
2421 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2422
2423 - corrected 48(!) wrong entries in the Next Neighbor table of the
2424 Magic Camera (all in the inner part of the outer ring, mostly
2425 missing a single NN)
2426
2427 - Fixed a bug in the table describing the Next Neighbours of the
2428 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2429 have any neighbour)
2430
2431 - changed trigrate.C: now it calculates the pure NSB triggers from
2432 a camera file (generated with no showers), so there is no need
2433 to introduce them by hand in the BgR array (for more details
2434 please ask Abelardo)
2435
2436 - added MHHadronness (and MHadronness) as a general facility to evaluate
2437 the quality of a gamma-hadron seperation method
2438
2439 - changed MWriteAsciiFile to accept rules (MDataChain)
2440
2441 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2442 must be replaced by calles to MWriteAsciiFile::AddColumn and
2443 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2444 changed.
2445
2446 - Implemented generalized event-matrices (one row per event)
2447 (MHMatrix)
2448
2449 - implemented the one dimensional composite probabilities
2450 (MHCompProb, MCompProbCalc, comprob.C)
2451
2452 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2453 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2454
2455 - Added a camera display displaying the pixel numbers to the
2456 event display gui.
2457
2458 - Added Monte Carlo Informations to event display gui
2459
2460 - Changed the camera display to display the pixel numbering
2461
2462 - Added three buttons to the camera display to change the palette
2463
2464 - Added the number of used and core pixels after image cleaning
2465 to MHillas
2466
2467 - Changed the algorithm used in MHillas according to TDAS 02-03
2468
2469 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2470
2471 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2472
2473 - Added fCosDeltaAlpha to MHillasSrc
2474
2475 - The numbers of photons used to calculate fConc and fConc1 in
2476 MHillasExt are now scaled with the pixel size, so that one get
2477 a four times smaller value for the bigger pixels in the outer ring.
2478
2479 - added new task to smooth the camera contents (MCameraSmooth)
2480
2481 - added possibility to use interpolated pixel values for blind pixels
2482 instead of removing it completely from the analysis
2483
2484 - Implemented the possibility to save the whole eventloop with
2485 its setup to a file. This information can be read and from
2486 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2487 and MEvtLoop::MakeMacro. If you find something not working, please
2488 report - this stuff is still in a beta phase.
2489
2490 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2491 file having crab starfield, but also for all following files - fixed
2492
2493 - MTaskList::PrintStatistics can now be instructud to print also the
2494 title, too: use PrintStatistics(0, kTRUE)
2495
2496 - Changed the image cleaning so that pixels with to many 'used'
2497 neighbors are left used (to get rid of 'holes' in events)
2498
2499 - Introduced more output to the camera displays
2500
2501 - Added an array of histograms (eg one hist per run), MHArray
2502
2503 - Added a _preliminary_ version of the reader for CT1 PreProc files
2504 (MCT1ReadPreProc)
2505
2506 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2507 (thanks to Raquel)
2508
2509 - added the first energy estimator (MEnergyEstParam, estimate.C,
2510 estfit.C) using a parametrization
2511
2512 - Added some new Monte Carlo paremeter containers used to store
2513 setup information from the MC chain (MMcConfigRunHeader,
2514 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2515
2516
2517
2518 *** Version 0.7 (2002/04/30)
2519
2520 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2521 the pedestal mean value was saved incorrectly. For files from
2522 this versions we substract 0.5 from the pedestal mean.
2523 WARNING: This may effect your results, so don't wonder...
2524
2525 - First implementation of an algorithm using only triggered events
2526 for the collection area calculation
2527
2528 - Ascii Output can now also be used for parameter containers which
2529 doesn't overload MParCointainer::AsciiWrite
2530
2531 - The Ascii Output is now also capable of writing single data members
2532 of one container
2533
2534 - You are now able to change the order of the values written to the
2535 ascii file
2536
2537 - You can now specify a conversion factor for each data member written
2538 to an ascii file. This may be usefull to change the units of the
2539 data member (eg. degrees instead of millimeters in case of the
2540 hillas parameters)
2541
2542 - Replaced old MHillas by a new structure which allows you to extend
2543 the parameters stored in MHillas very easily:
2544 see MHillas and MHillasExt
2545
2546 - Added classes to handle source dependancy of image parameters:
2547 see MHillasSrc
2548
2549 - Added container (MBinning) to have a standard input for the binning
2550 in different histograms (eg. the Energy bins should be the same in
2551 all histograms)
2552
2553 - Changed Hillas histograms from mm to deg
2554
2555 - Added the flexible binning to the hillas histograms
2556
2557 - Added a filter for the alpha parameter (MFAlpha)
2558
2559 - It is now possible to write single data members of a class object to
2560 an output stream instead of the whole container only
2561
2562 - Added a generalized filter for a data member:
2563 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2564
2565 - Added a generalized Filter parser for more difficult filter rules
2566 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2567
2568 - Added new Monte Carlo histograms:
2569 MHMcEnergyImpact and MHMcEfficiency
2570
2571 - Added many new histograms needed for the flux calculation.
2572
2573 - Added a generalized histograms which can fill and show up to three
2574 data members in either a one-, two- or three-dimensional histogram, eg:
2575 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2576
2577 - Added:
2578 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2579 * calculation of <Theta> as a function of time (MHThetabarTime)
2580 they are needed in the flux calculation in
2581 order to select for a given bin in Theta (or time) the appropriate
2582 effective collection area, which is assumed to be given as a function
2583 of Theta and the true energy
2584
2585 - Added calculation of the migration matrix in the energy
2586 (MHMcEnergyMigration):
2587 the migration matrix describes the migration from the true (E_true)
2588 to the estimated energy (E_est); it is needed to determine the
2589 distribution of E_true from the measured distribution of E_est
2590 by unfolding
2591
2592 - changed the color palette in the camera display to DeapSea.
2593
2594
2595
2596 *** Version 0.6 (2002/01/15)
2597
2598 - Introduce the option of disable pixels (MBlindPixels and
2599 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2600 able to deal with Star Field NSB.
2601
2602 - Fixed a bug in the pedestals substraction
2603
2604 - Introduced verbosity levels
2605
2606 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2607
2608 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2609 work correctly (thanks to Abelardo)
2610
2611 - Introduced correct treatment of the diffuse Night Sky Background
2612 and NSB (MMcPedestalNSB)
2613
2614 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2615
2616 - Introduced MMcRunHeaders which contains monte carlo run informations
2617
2618 - Added a 'Print'-Task (MPrint) which calls the Print function
2619 of a parameter container for each event
2620
2621 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2622
2623 - changes to be more efficient with root 3.02/06
2624
2625 - root 3.02/06 fixes:
2626 + the memory leak when reading MRawEvtData
2627 + loosing more time than necessary to update the progress bar
2628
2629 - MWriteAsciiFile is now capable of writing more than one container
2630 in a line. For example: To be able to write Monte Carlo and
2631 Hillas values (energy and alpha) in one line.
2632
2633
2634
2635 *** Version 0.5 (2001/11/06)
2636
2637 - Added new GUI functionality (Analysis)
2638
2639 - Added a camera display to be able to display events in the camera
2640 together with the calculated hillas ellipse
2641
2642 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2643 object at any state of the analysis, so that the output are several
2644 states
2645
2646 - Fixed a bug in the collection area error calculation
2647 (Thanks to Ciro and Abelardo)
2648
2649 - Fixed a bug which causes merpp to crash in some environments
2650
2651 - Implemented auto enabling scheme for Branches to speed up reading
2652 a lot (see MReadTree and MTask)
2653
2654 - Fixed a bug in the Histogram classes which caused histograms to
2655 be written to a file by MWriteRootFile without request
2656
2657 - changed the object I/O from the old stylish root I/O to the new
2658 'auto evolution scheme' This was done only for classes which are not
2659 yet used in Monte Carlo files, so that these files are still readable.
2660
2661 - Added support for a progress bar in MEvtLoop and MReadTree
2662 (see the Analysis Window in Mars for an example)
2663
2664 - Fixed a bug in the package creation which disturbed the conversion
2665 between a mars version unpacked from a tar file and the repository.
2666
2667 - Changed the code to writer merpped (converted into root format)
2668 raw files, to get faster (around 10%)
2669
2670
2671
2672 *** Version 0.4 (2001/09/20)
2673
2674 - This release is made to compile on a root version >= 3.00
2675
2676 - Fixed a bug which causes MReadTree to read the first file only
2677
2678 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2679
2680 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2681
2682 - Added a task to write several container to a root file (MWriteRootFile)
2683
2684 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2685
2686 - Added calculation of the collection area (MMcCollectionAreaCalc)
2687
2688 - fixed some bugs in the Hillas calculation
2689
2690 - added filters to be able to control the task execution dependent on
2691 a parameter (for example: the number of level 1 triggers in a MC-file)
2692
2693
2694
2695 *** Version 0.3 (2001/04/23)
2696
2697 - Many demo macros added
2698
2699 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2700
2701 - Hillas Calculation added
2702
2703 - Standard image cleaning available
2704
2705 - MReadTree is now able to handle more than one file
2706 (Remark: of the same structure)
2707
2708 - Now we are able to display events in a first version of the
2709 Camera event display. To do this we must run the macro
2710 "macros/readCT1.C" to read data from CT1.
2711
2712
2713
2714 *** Version 0.2 (2001/01/24)
2715
2716 - First Implementation of a Gui to read the raw data. Start the
2717 gui with the command mars.
2718
2719
2720
2721 *** Version 0.1 (2000/12/20)
2722
2723 - First official release 0.1
2724
2725 - Changes:
2726
2727 + changed calling style of MRawPixelIterator from do...while to
2728 while-loop
Note: See TracBrowser for help on using the repository browser.