source: trunk/MagicSoft/Mars/NEWS@ 8386

Last change on this file since 8386 was 8386, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 86.9 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - mars: The default cleaning is now Abolsute 8.5/4.0.
6
7 - mars: The resource file mars.rc now contains examples for MUX data
8
9 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
10 data containing only 10-bit information is still cooked down to
11 8-bit, by cutting away the lowest 8-bit.
12
13 - merpp: When reading raw data the data is now stored in a single
14 array. The lo-gain array is obsolete. The interface stays the same.
15
16 - callisto: Improved binning for the pulse position check histogram
17
18 - callisto: The code calculating the pulse position checknow takes
19 the pedestal into account
20
21 - ganymed: The output files now contain run- and event-number for all
22 events, accessible as RunNumber.fVal and EvtNumber.fVal
23
24 - ganymed: Added a plot showing the source position in the camera also
25 for wobble mode
26
27
28
29 *** Version 1.0 (2007/02/16)
30
31 - database: Website to plot values from the database has been added.
32
33 - database: The rate of spark events as found by star is now kept
34 and the rate after cleaning is now with spark events subtracted
35
36 - general: The changes to the interpretation of phrases lead to
37 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
38
39 - general: Added example files how you can create your own calendar
40 (eg. as christmas present) with Mars. Just run
41 root macros/tutorials/calendar.C
42
43 - general: Added a possibility to display grouped data in the plotdb.C
44 macro (and similar macros). This allows to plot hourly, nightly,
45 weekly, monthly and yearly averages.
46 For more details see the plotall function of the macro
47
48 - general: fixed the error display of the camera display. It showed
49 wrong results.
50
51 - general: fixed a memory leak when reading many MStatusDisplays
52
53 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
54 between a spherical and a parabolic mirror
55
56 - callisto: We have a new pulse position check which takes the properties
57 of the extractor automatically into account. So no need to set
58 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
59 left is done. If possible the lo-gain extraction start and hi-gain
60 extraction end is changed accordingly. If no proper extraction range
61 can be set (hi-gain too much to the left) an error is raised.
62
63 - callisto: New swapped pixels have been found and corrected
64
65 - callisto: Redone the signal extraction this includes:
66 + Unified the algorithms to extract the pedestal for all pedestal
67 extractions done
68 + Unification of hi- and lo-gain into one array
69 + Unification of hi- and lo-gain extraction for Spline and
70 Digital Filter (means now exactly the same algorithm is used,
71 not a copy-and-pasted one)
72 + Store pedestal subtracted data in a common place
73 + Improved extraction algorithms. If the algorithms search a
74 maximum but don't find one they don't return the maximum anymore
75 + Improved the extraction such that a information for signal
76 and time which is consistent is returned
77 + replaced the numerical spline with a (not slower) analytical
78 solution
79 + Lowered the saturation limit from 250 to 245 to make sure that
80 we are far away in all pixels from problems with the clock-noise
81 + The start of the lo-gain extraction is calculated from the hi-gain
82 arrival time. In case of saturation an estimation is used.
83 + the hi-gain window was extended to slice 16. This allows extraction
84 of very late pulses in single pixels or of huge hadron showers.
85 + Now uses the lo-gain extraction range for pedestal extraction,
86 not the hi-gain range in the lo-gain
87
88 - callisto: New hi-/lo-gain calibration constants have been produced
89 for all periods from the statistic of the whole period. They are
90 now used automatically depending on the periods. The old constants
91 where deviation in avarega about 2%-3%. The constants are very
92 stable from period to period (<<1%) except for exchanged channels.
93 In a few cases the constants used so far were off by 1%-2% (maybe
94 temperature effects?)
95
96 - callisto: To gain obsolete space we do not write the
97 MPedestalFundamental anymore. Also calibration and bad pixel
98 treatment is not done for it anymore because it has never been used.
99
100 - callisto: Fixed a bug in the seuqence handling which caused the
101 light condition to be ignored
102
103 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
104 basically the same as "Cleaned" but the distribution devided into
105 the events fullfilling a spark cut or being rejected by it.
106 This cut can be changed from star.rc (see example inside) by
107 the "SparkCut" directive
108
109 - star: Star displays now the average individual pixel-rate (IPR) versus
110 time and the average discriminator threshold (DT) of all pixels.
111
112 - optim: fixed a problem with the optim-macros which was due to a bug
113 in the new phrase parsing
114
115 - ganymed: To get a nice FalseSource plot (instead of the all-information
116 debug plot displayed as a standard plot) use the context menu
117 somewhere between the two upper plots, click on "DrawNicePlot"
118 and enjoy the result. (It is the same context menu which contains
119 the other options)
120 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
121
122 - ganymed/optim/train: The cut program, trainings- and optimization
123 macros could run with less files found than expected from the
124 sequence-files. No the execution is stopped in this case.
125
126 - ganymed: now stores the dataset in the output file with all information
127 contained (as sequence number, sequence path, data path) so that the
128 used dataset file can be recreated complete from the output
129
130 - sponde: now also allows the uasge of random forest
131
132 - sponde: added a plot showing the cut efficiency
133
134 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
135 errors (eg. effecting the collection area) because the errors of the
136 two histograms were swapped in the calculation, which makes a difference
137 in the case the histograms contains weighted events. Aditionally the
138 totalarea was incorrectly taken into account, which results in too small
139 errors, which makes a difference at low statistics were the errors
140 or the collection area dominate.
141
142
143
144 *** Version 0.10.3 (2006/10/23)
145
146 - database: Implemented ObservationMode flag in websites.
147
148 - database: For sequences there is now also the stoptime available on the
149 websites.
150
151 - database: Removed ManuallyChanged flag from sequence-info websites,
152 as it is not needed anymore with the new sequence building algorithm.
153
154 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
155 Class for calculation of confidence intervals (upper limits).
156 Use model 3 or 4 for upper limit calculation for MAGIC observations.
157 Please read the class instruction of TRolke for more information.
158
159 - general: The programs now return 0xfe if the requested resource file
160 doesn't exist.
161
162 - general: Errors comming from root itself are now not output to
163 stderr anymore but to our default (colored) log-stream.
164
165 - general: Changed the interface to TFormula such that now everything
166 is parsed by TFormula, which should allow to use phrases even
167 without paranthesis correctly parsed.
168
169 - callisto: replaced the AdHoc number of effective integration slices
170 in the digital filter by an average of the correct number, averaged
171 over all possible set of weights. This also gives correct numbers
172 for the lo-gains which were totally wrong before.
173
174 - callisto: drastically reduced memory consumption by not storing
175 all intermediate calibration results in memory anymore (we might
176 write them into a file in the future)
177
178 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
179 debug plot displayed as a standard plot) use the context menu
180 somewhere between the two upper plots, click on "DrawNicePlot"
181 and enjoy the result. (It is the same context menu which contains
182 the "DrawAll" option)
183 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
184
185
186
187 *** Version 0.10.2 (2006/10/15)
188
189 - general: changed the building of the sequence files such, that
190 the source-/project name in case of wobble-sources is not the
191 source/project of the first data run anymore but the new generalized
192 wobble source/project
193
194 - general: Added some functions to MAstro to calculate sun and
195 moon properties
196
197 - general: Added two new macros (starvisday.C and starvisyear.C)
198 which allow to plot the visibility of several stars in one day
199 or of one star along one year
200
201
202
203 *** Version 0.10.1 (2006/10/11)
204
205 - general: HTML logging output was distorted... fixed.
206
207 - general: Changed the writing of the sequencefiles such that only
208 as many pedestal files as giving at least 1000 pedestal events which
209 are nearby the first calibration run are used as pedestal runs
210
211 - sponde: In the calculation of the collection area(s) and the
212 distribution for MOnte Carlo and estimated energy the error
213 calculation was wrong because root didn't take the errors
214 properly into account... fixed.
215
216
217
218 *** Version 0.10 (2006/10/10)
219
220 - general: all executables now check consistency of the root version
221 installed with the root version used for compilation. The return
222 code in this case is 255.
223
224 - general: The algorithm to build seqeunces has been redesigned
225 completly. It is now more flexible in terms of a resource file
226 resources/sequences.rc which can be used to partly overwrite
227 the default algorithm and defined the important part of the
228 algorithm. It also takes correctly into account several ways
229 of taking wobble-data. Currently the new algorithm doesn't take
230 the number of pedestal events anymore into account (so a sequence
231 could have much less than 1000 pedestal events and data runs are
232 no-more used instead)
233
234 - general: a lot of small changes to make the code compatible with
235 root 5.12/00 and gcc 4.1
236
237 - general: Fixed some warnings thrown if more warnings are switched
238 on in the compiler
239
240 - general: Added a function to MMath which returns the Median of
241 the distribution abs(y[i]-median) but at 68:32 division instead
242 of 50:50, which is somehow the median counterpart of the rms.
243
244 - general: MAstroCatalog allows now to read calatog files (as bsc5)
245 even if they are compressed with gzip (recommended compression
246 is with "-1")
247
248 - showplot:
249 + batch mode creation of image files now works with root 5.12/00
250 + added support for writing bmp (though it never produces
251 bmp which can be read by programs like xv or gimp)
252 + added support for xml
253 + added new option to start the display with a different size, by
254 --display-width=nnn or --display-height=nnn
255 + added options to define the canvas size when the display is started
256 --canvas-width=nnn or --canvas-height=nnn
257 the option can also be used for batch-mode conversion
258 + added an option which automatically fits the display size to the
259 desktop-size: --auto-size
260
261 - merpp: didn't recognize files with the extension .raw.gz - fixed.
262
263 - merpp: allow the reports to have 1000ms due to a bug in the camera
264 program.
265
266 - callisto: New swapped pixels have been found and corrected. For
267 details see MRawRunHeader::FixAssignment()
268
269 - callisto: Callisto now raises an error if one of the input files could
270 not be opened.
271
272 - callisto: In some rare cases it could happen that in the signal
273 extraction of the digital filter the extractor returned nonsense
274 results due a wrong initializion of a variable (this happens in
275 cases in which the extracted signal is exactly zero or the
276 digital filter couldn't slide because of a too small extraction
277 window, which could happen in the lo-gain extraction)
278
279 - callisto: The lo-gains have been marked as valid in some cases
280 when they got not extracted at all (deltsumlo=deltatimelo=0) because
281 the allowed extraction range (fLoGainLast-fLoGainFirst) was
282 smaller than the number of slices (fLoGainWindowSize) needed
283 by the lo-gain extractor
284
285 - callisto: Updated absolute calibration constants (muon calibration)
286
287 - callisto: fixed a bug which caused the hi-gain saturation not
288 to be handled properly in the spline (the position of the
289 saturation was calculated incorrectly)
290
291 - callisto: fixed a bug which gave weird results if hi- _and_
292 lo-gain could not be extracted properly. In some cases hi-
293 and lo-gain have not been extracted at all and the random result
294 got calibrated. In other cases the hi-gain was saturating and the
295 lo-gain has not been extracted. For this a completly arbitraty
296 scale factor was applied to the result from extracting the
297 charge of the saturating hi-gain.
298
299 - callisto: improves handling of extracted signal if lo- and/or
300 hi-gain could not be extracted properly. If no appropriate
301 calibration of either the signal or the arrival time is possible
302 the pixel is now markes as unsuitable instead of estimated.
303
304 - callisto: Fixed a problem in the spline extraction which gave
305 weird results if the signal was extracted from the first (and
306 highest) slice (as a workaround extraction from the first
307 slice has been forbidden)
308
309 - callisto: Fixed a bug regarding the use of the QE which doesn't
310 effect the result because the default is used anyhow.
311 (The bug was there since 14/07/2005)
312
313 - callisto: Changed the default for fgLoGainStartShift to -2.4
314
315 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
316 factors to be always 10 for all pixels as soon as the first
317 calibration update has happend.
318
319 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
320 was off by more than one slice (which gives wrong values for
321 pixels which have saturated the hi-gain) This was a problem
322 mainly for timing studies, not so much for the automatic standard
323 analysis. Also the values for the Spline have been changed slightly:
324 + Digital Filter from 1.70 to 0.95
325 + Spline from 1.39 to 1.30
326 The numbers were sorted out by an extensive test in the
327 test-database.
328
329 - callisto: Removed the tab showing the average calibrated arrival
330 time. It never gave useful information.
331
332 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
333 lo-gain pulse for data pulses if hi- and lo-gain have saturated
334 and both were extracted because the hi-gain was above the
335 LoGainSwitch.
336
337 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
338 lo-gain pulse position (after application of LoGainOffset, which
339 means in the ideal case it is 0) for data pulses if hi- and lo-gain
340 have saturated and both were extracted because the hi-gain was above
341 the LoGainSwitch.
342
343 - callisto: After extensive tests a new threshold level for determination
344 of the pulse position has been found at 50phe. This is due to the
345 fact that for lower pulses the arrival time changes its average
346 behaviour dramatically. It tends to the average of the extraction
347 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
348
349 - callisto: Added two more plots to the calibration part. The average
350 extracted signal and the average extracted arrival time as
351 extracted by the signal extractor (This can help debugging problems
352 because it doesn't involve a fit)
353
354 - star: changed the fit for the effective on time such that initial
355 values are calculated automatically now instead of using build
356 in values. This makes the fit more indepedant of the underlaying
357 rates. With a test of ~350 sequences in the test database it could
358 be shown that the new fit gives the same result +/-1sek.
359 The highest deviation was +5s the lowest -10s. You can now control
360 the bahaviour with two resource values:
361 MHEffectiveOnTime.FistBin: 3
362 MHEffectiveOnTime.NumEvents: 12000
363 Use FirstBin=1 and NumEvents=120 to fit the effective on time
364 from the resulting gamma candidates
365
366 - star: The Center histogram in MHHillas is now by default displayed
367 with the colz draw-option
368
369 - ganymed: now produces valid error codes if failed
370
371 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
372 with the option "hadronness" instead of "area" or "both" if
373 you want to use both cuts. The hadronness cut includes a fixed
374 cut in hadronness (index 8) and a fixed cut in size (index 9).
375
376 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
377 the M3Long of the anti source to be not properly evaluated
378 (actually is was evaluated as a unique random number) in case
379 of optimization with anti-theta cut switched on. This might have
380 lead to improper, but not necessarily wrong, optimization results.
381
382 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
383 how to use random forest
384
385 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
386 ganymed_onoff.rc. Seems to be unintentional that they were different.
387
388 - sponde: Since the introduction of the possibility to define a
389 normalization energy instead of using the integral the default
390 was not using the integral anymore but a normalization energy of
391 1GeV. It is now the integral again.
392
393 - sponde: Fixed a problem in the weighting which did not allow
394 a MC slope of -1.
395
396
397
398 *** Version 0.9.6 (2006/05/24)
399
400 - general: changed the binning of the azimuthal profile of the camera
401 such that it is aligned with the 60deg boundaries.
402
403 - merpp: better handling of problems with the TH, TD part of the
404 CC-REPORT for files older than 200507190 and 200412210
405 respectively
406
407 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
408
409 - merpp: implementd latest changes in starguider reports (sinc 9th May)
410
411 - callisto: if an arrival time is extracted outside the fadc range is
412 was set to the boundary before. Now a random number is assigned
413 instead to avoid unfortunate coincidences of arrival times just
414 by this arbitrary value.
415
416 - callisto: added a new option to callisto.rc which allows
417 to set the maximum arrival time difference allowed for the
418 badpixel algorithm to determin whether a pixels belongs to a shower:
419 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
420
421 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
422 to 0.9 as suggested by Stefan due to a recent study on the fraction
423 of pixels surviving the image cleaning
424
425 - callisto: switched off error in case of "pulse is too much to the left"
426
427 - callisto: The extraction window is not adapted anymore. This means that
428 the pulse is extracted from the full range. The draw-back is that the
429 background (pedestal) will become slightly higher. Switching on/off
430 the PulsePosCheck in the callisto.rc only effects filling the
431 histograms.
432 WARNING: If the pulse is too much to the left data is calibrated!
433 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
434 in the database to make sure that your data is valid!
435
436 - star: Show also the number of stars correlated correctly by the
437 starguider
438
439 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
440 than one off-source region in wobble-mode. To use it add the following to
441 your ganymed_wobble.rc:
442 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
443 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
444 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
445 + Cut1.ThetaCut: None
446 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
447
448 - ganymed: in the case the latest report is older than a default (currently
449 one minute) and the current report will be skip the starguider
450 correction and calibration will be reset. The maximum age can be
451 setup from ganymed.rc by (minutes):
452 MPointingDevCalc.MaxAge: 1.5
453
454 - ganymed: A first implementation showing all size-bins for the theta-sq
455 resp. alpha-plots in a single tab automatically
456
457
458
459 *** Version 0.9.5.1 (2006/05/05)
460
461 - general: Added a new option "zdiff" to the Makefile which runs
462 "cvs diff" as "make diff" would do, but with compression
463
464 - general: accelerated MTFillMatrix (used for eample in all training
465 and optimization macros) by skipping some obsolete calles in the
466 eventloop the first and second loop could be accelerated by ~20%
467
468 - general: Added a missing feature in the MFilterList class which
469 prevented MFEnergySlope from working correctly in trainenergy.C
470
471 - general: Accelerated the random forest training and usage a bit
472
473 - merpp: Adapted to new raw data file format version 6
474
475 - merpp: fixed a problem with reading the starguider reports
476 after 6.3.2006
477
478 - callisto: At some times six pixels had to be exchanged manually in the
479 data. If the pixels to be swaped are both not found, an error was raised
480 and calibration was stopped. Now it is assumed they are intentially not
481 mapped and the Error has been changed to a Warning.
482
483 - star: Added new image cleaning based on the arrival time of the shower.
484 The new cleaning can be accessed using the parameter "Time" instead of
485 the the old one (like "Absolute) in the star.rc-file.
486 Recommended parameters:
487 + MImgCleanStd.CleanLevel1: 8.2
488 + MImgCleanStd.CleanLevel2: 5
489 + MImgCleanStd.CleanRings: 2
490 + MImgCleanStd.KeepSinglePixels: No
491
492 - star: Simplified the calculation of the effective on time. By letting
493 the fit start in the third bin the result should become more stable.
494 The fit quality is now ignored for the theta-plot which is not used
495 in the analysis later. Still better pre-cut which, for example,
496 remove events triggered by car-light (rate changing on a short
497 time-scale) are missing.
498
499 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
500 for optimization (kWeakSource) which is suggested by the Berlin
501 people for weak sources.
502
503 - macros: plotdb.C:
504 + if no dataset and no time-interval is given only sequences with
505 an effective on-time above five minutes are plotted anymore
506 + added a new tab "RelTime" displaying the relative on-time
507 (effective on-time divided by the observation time)
508
509 - macros: optim*.C: by skipping some obsolete calles in the eventloop
510 the optimization became a lot faster
511
512 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
513 To display them just delete the pads displayed on top.
514
515 - ganymed: fixed a bug which could cause strange behaviour in wobble
516 mode if no starguider information was available due to an incorrect
517 initialization of the starguider calibration
518
519 - ganymed: The scale region in the False Source Plot (MHDisp) can now
520 be changed from within the plot. It can also be setup from the
521 resource file using:
522 + MHDisp.fScaleMin: 0.325
523 + MHDisp.fScaleMax: 0.475
524
525 - ganymed, showplot: Fixed a problem with the fit to the off-data
526 (HistOff) which could cause a time lag or an inifinite loop.
527 The bug did not effect the results at all.
528
529 - sponde: Added a new tab showing the effective collection area after
530 trigger (including the software trigger)
531
532 - sponde: MMcSpectrumWeight has a new option which allows to define
533 the scaling factor not by the integral of the events but at
534 a defined energy:
535 e.g. MMcSpectrumWeight.NormEnergy: 200
536
537 - MTFillMatrix, sponde: by skipping some obsolete calles in the
538 eventloops the loop could be accelerated by ~20%
539
540
541
542 *** Version 0.9.5 (2006/03/13)
543
544 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
545 and added the standard Disp-parametrization
546
547 - macros: added a new macro datacenter/macros/plotstat.C allowing
548 to plot statistics about the data processing
549
550 - macros: added a new macro to plot the muon correction coefficients
551 versus period (macros/plot/mucal.C)
552
553 - showplot: path inflation for ganymed files was broken
554
555 - callisto: Fixed an important bug. When the number of saturating pixels
556 were calculated the bad pixel information already available from the
557 calibration was ignored. This yields wrong values in case pixels
558 are broken and saturate all the time or randomly.
559
560 - callisto: Updated Muon calibration constants. Spline data now also uses
561 different values for different periods
562
563 - star: The time-evolution shown in the effective on-time plot now displays
564 the axis range (if there are no holes it should be similar to the
565 effective on-time)
566
567 - star: Added two new image parameters:
568 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
569 the three pixels next to the center of gravity and the size
570 + MNewImagePar.fConcCore: The ratio of the signals of all
571 pixels inside or touching the ellipse and the size
572
573 - ganymed: now stops in requested source isn't found in catalog file
574
575 - ganymed: Many improvements to the phi-plot in wobble mode:
576 + with a template the ideal background is displayed
577 + a possible camera inhomogeneity is taken into account
578 + the anti theta cut is better supported
579 + the phi cut is automatically calculated from the theta cut
580 See the examples in ganymed_wobble.rc for more details.
581
582 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
583 times the bin-width instead of the absolute energy
584
585 - ganymed: New cuts for on/off and wobble mode
586
587 - ganymed: The smearing of the False Source plot has been increased
588 to 0.06
589
590 - ganymed: The starguider calibration can now be changed from the
591 resource file.
592 See the examples in ganymed*.rc for more details.
593
594 - ganymed: added a new option for on-/off-observations
595 MJCut.RandomSourcePosition
596 If switched on the distribution of observation time of the source
597 position in the camera is calculated from the on-data and randomly
598 applied with this distrbution to the off-data.
599
600 - ganymed: by skipping some obsolete calles in the eventloop the
601 first and second loop could be accelerated by ~20%
602
603 - ganymed: The default in ganymed_onoff.rc is now to determin the source
604 position in the off-data randomly according to its distribution in the
605 on-data.
606
607
608
609 *** Version 0.9.4.3 (2006/02/13)
610
611 - general: Fixed a bug in most of the programs which prevented the
612 compile date in the startup message to be displayed
613
614 - general: Simplified program calls. The following abbreviations
615 are now possible:
616 showlog callisto 55599
617 showplot signal 55599
618 star 55599
619 callisto 55999
620 ganymed 2
621 In this cases the corrsponding root-, log-, sequence- or dataset-
622 filename is automatically compiled using the default datacenter
623 paths ("/magic/*")
624
625 - general: Fixed a long outstanding bug which made axis tick marks
626 disappear if MDataFormula was used (eg. abs(x))
627
628 - general: Updated MMath with new functions to calculate the results of
629 a exponential, logarithmic and powerlaw fits analytically.
630
631 - general: Updated some macros with comments:
632 + macros/optim/optimdisp.C
633 + macros/optim/optimenergy.C
634 + macros/optim/optimwobble.C:
635
636 - general: MTFillMatrix (the class to fill one or two MHMatrix from
637 files) now allows adding a pre-cut like in the optimization. E.g. this
638 is useful to perform g/h-separation cuts before training the random
639 forest.
640
641 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
642 correctly assigned in the raw data assignement table. A fix to correct
643 the assignment tabel have been implemented.
644
645 - general: MAstroCatalog now allows rotating of the sky-grid and stars
646 by 90, 180 and 270 deg.
647
648 - general: the macro plotdb.C now allows to highlight sequences belonging
649 to a datset. For more details see the descritions in the macro.
650
651 - StatusDisplay: Fixed the algorithm to calculate the size ratio
652 of the display, it gave wrong results espacially for big sizes.
653 Now the embedded canvas should always have a ratio width/height=3/2.
654 The "Size" options have been updated with values fitting the 3/2
655 size ratio.
656
657 - RanForest:
658 + Updated the random forest classes to support also the
659 regression method implemented by Thomas H.
660 + added new tutorial macro how to train the random forest
661 for energy estimation (macros/optim/rfenergyest.C)
662 + new classes to train the random forest (still in development)
663 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
664 + new tutorial macros for random forest training in macros/train
665 trainenergy.C, traindisp.C, trainseparation.C
666
667 - mars: now allows to setup a cut in the resource file mars.rc to choose
668 the events to be displayed, eg:
669 Cut.Condition: {0} && {1}
670 Cut.0: MHillas.fSize>100
671 Cut.1: MHillas.fSize<900
672
673 - merpp: Made aware of the new .rep format 200510250. This includes
674 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
675 the discriminator thresholds (MCameraTD) and the disciminator
676 delays (MCameraTD). All of them come with the CC report and are therefor
677 written to the CC tree.
678
679 - callisto: fixed a bug in the calculation of the arrival times in
680 the Digital Filter. They were all shifted by the same amount
681 fHiGainFirst. This caused an offset in the order of the position of
682 the left border of the extraction window in the times calculated
683 from high-gain and from low-gain. The bug effected only the absolute
684 arrival times. The bug was there since 30.1.2005.
685
686 - callisto: Changed the ExtractionWindow for the pulse position check
687 such that the camera inhomogeneity becomes as less as possible and
688 comparable to the pulso position check switched off. More details
689 on the study will be given at our result web-page.
690
691 - ganymed: ganymed.rc, ganymed_onoff.rc:
692 changed to new cuts trained with 1ES1218 and Crab-data
693 for maximum sigma*log10(excess)
694
695 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
696 a new option was implemented to estimate Disp (CalcDisp)
697
698 - ganymed: Implemented two new options which allow
699 to overwrite the default path to search for the sequence files
700 --ins=/magic/sequences
701 and where to search for the image data
702 --ind=/magic/data/star
703
704 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
705 dx/dy from the resource file by
706 MSrcPosCorrect.Dx
707 MSrcPosCorrect.Dy
708
709 - ganymed: fixed reading the source catalog. Only as many chars
710 as the requested source name had were compared (If a source
711 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
712 were requested it could happen that the coordinates of
713 "1ES1218" were read) The source coordinates are now printed
714 in addition to its name to the logging output.
715
716 - ganymed: changed the background fit in the case of a ThetaSq function
717 from a polynomial to a exponential, this should give a big improvement
718 for on-only analysis'
719
720 - ganymed/sponde: Calculation of the error of single size-/energy-
721 bins now uses Li/Ma (5) instead of LiMa (17)
722
723 - sponde: Added a plot E^2*dN/dE
724
725 - sponde: The energy estimator plot should now show values like
726 they are commonly used.
727
728 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
729 (a powerlaw with cutoff didn't work before)
730
731
732
733 *** Version 0.9.4.2 (2005/10/01)
734
735 - general: added new tutorial macro macros/tutorials/threshold.C:
736 how to calculate the threshold
737
738 - general: added a new game. Start it from the interpreter with
739 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
740 and MagicReversi)
741
742 - general: neighbor pixels in MGeoms are now sorted clockwise
743
744 - merpp: made aware of new format 20050829-0
745
746 - callisto: New scale factors from muon analysis, stored in new
747 resource file resources/calibration.rc
748
749 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
750 the eventloop if something went wrong. This is necessary for the
751 automatic processing
752
753 - callisto: Implemented a new treatment for the time information
754 developed by S.Ruegamer, this should give much better response than
755 the old very primitive algorithm. This is especially important
756 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
757 treatment was buggy! As neighbor pixels to interpolate the
758 arrival times always the pixels 0 to 5 were taken)
759
760 - callisto: In addition to the new treatment of arrival times the
761 decision of the treatment whether a pixel contains shower
762 information or not is used to improve the signal interpolation
763 further. Previously interpolated pixels showed a non-zero signal
764 do the peak searching signal extractors. Having a signal pixel
765 beside raised the signal above the cleaning level. Thus the
766 pixel survived cleaning to often but with a too low mean signal.
767 By replacing empty pixels with a gaus (mean and rms from the
768 corresponding Area entries in MPedPhotCam) this effect can
769 be supressed.
770
771 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
772 got lost when the events were stored by the calibration... fixed.
773 (This was no problem for normal image cleaning because the pixel
774 content was artificially set to 0 not surviving standard cleaning
775 algorithm)
776
777 - callisto: Fixed a bug which caused the random and peak-search pedestal
778 extracted with an extractor to be exchanged for the first (roughly)
779 500 events (*Extractor and *ExtractorRndm).
780 (They were simply exchanged in callisto.cc) This bug might have been
781 introduced in Mars 0.9.4 when the order of calculation of the two
782 types of pedestal in callisto got exchanged. The bug only effects
783 the first seconds of data of each sequence.
784
785 - star: Taking the arrival time of Muons into account the calculation
786 of the parameters could be made independant of the noise
787 (pedestal rms). The dependance was due to the bias of the peak search
788 extractor. Now only a ZA dependamcy is left which is not yet fully
789 understood.
790
791 - ganymed: The sequences were still not sorted correctly in any case,
792 because they were sorted by the full qualified path name. Now they
793 are sorted by their sequence number.
794
795 - ganymed: new values for the spark-event-cut
796
797 - sponde: required missing MEnergyEst from ganymed.root... fixed.
798
799
800
801 *** Version 0.9.4.1 (2005/08/18)
802
803 - callisto: fixed some problems with the calibration in case of
804 inteleaved events. Therefor the final and some intermediate
805 fits are skipped which would take place on partly filled #
806 histograms and gave wrong results or failed completely.
807
808 - callisto: If the intermediate finalization of the histograms
809 calculating the mean charge of the calibration signal fails
810 it is counted now and printed in PostProcess of MCalibCalcFromPast.
811
812 - ganymed: Fixed some bugs which caused problems in On-only mode.
813 Still the false source plot doesn't give reasonable results.
814
815
816
817 *** Version 0.9.4 (2005/08/05)
818
819 - general: Fixed the ZA binning. It did not correctly fit the
820 MC binning
821
822 - general: Added a class to correct for the missfocussing in
823 April (MSrcPosCorrect)
824
825 - general: Random Forest energy estimator should now work properly
826
827 - general: MHCamera now displays the profiles in deg instead of mm
828
829 - general: MH::SetPalette offers a lot of new palettes
830
831 - general: MHillas - the case of CorrXY==0 is now handled properly
832
833 - general: implemented the possibility to change the line and
834 marker style of a sky-grid drawn by MAstroCatalog
835
836 - general: Runs in sequences and datasets are now automatically
837 ordered (it is assumed that the order of their filenames correctly
838 represents the order of observations) to ensure correct reading
839 of the subsystem data
840
841 - general: Runs cannot be added to a sequence twice anymore. Also
842 Sequences cannot be added twice anymore to a dataset.
843
844 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
845 It gave wrong results by 1./2pi
846
847 - showplot: got a new option to start a root interpreter, too
848
849 - mars: now displays a rough estimate of Disp and the third moment
850
851 - mars: now displays the event time MTime if available
852
853 - mars: show muon parameters graphically
854
855 - mars: now the file to open can be given as commandline
856 argument
857
858 - merpp: Added support for new arehucas version >= 200507190
859 implementing values for three temperature sensors in the
860 counting house (MCameraAUX) and the name of the HV settings file
861 (MCameraHV).
862
863 - merrp: Also fixed some problems with wrong versions numbers stated
864 by arehucas and implemented some fixed for old versions (<200407070)
865
866 - callisto: MCalibrationHiLoCam can now be printed from its context
867 menu, eg in the TBrowser
868
869 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
870 - 1.39 (MExtractTimeAndChargeSpline)
871 - 1.40 (MExtractTimeAndChargeDigitalFilter)
872 This is important mainly for timing studies.
873
874 - callisto: Changed limits in MHCalibrationChargeCalc from
875 - -100.125 to -98 (fgChargeHiGainFirst)
876 - 1899.875 to 1902. (fgChargeHiGainLast)
877 - -100.25 to -99 (fgChargeLoGainFirst)
878 - 899.75 to 901. (fgChargeLoGainLast)
879 Introduced new limits:
880 - fgNumLoGainBlackoutLimit: 0.05
881 - fgLoGainBlackoutLimit: 3.5
882 - fgLoGainPickupLimit: 3.5
883
884 - callisto: The handling of automatic weights for the digital filter
885 has been improved. There are now new calibration weights special
886 for Monte Carlo calibrations.
887
888 - callisto: Updated Muon scale with latest results (1% difference
889 for most data, 5% for Mar/Apr'05)
890
891 - callisto: use a new criterium to exclude bad pixels: If the high-gain
892 was saturated and the blackout-events in the low-gain exceed the
893 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
894 This excludes those pixels which have a saturating high-gain
895 channel, but the low-gain switch does not switch often enough
896 to make the distribution reliable.
897
898 - callisto: fix a bug counting the number of saturated events. Up to now,
899 the number of saturated slices was counted (which is one for a not too
900 high number), but for some (pathological) pixels, many more slices
901 saturated and produced wrong limits.
902
903 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
904 + MCalibrationRelTimeCam.CheckFitResults: Yes
905 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
906 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
907 + MCalibrationRelTimeCam.CheckOscillations: Yes
908
909 - callisto: introduce max. number of events for intercalibration,
910 the rest gets skipped. Default: 4096
911 The calibration causes too many un-reliable pixels if more
912 than about 5000 events are treated (@500 Hz) because of the
913 mode hopping of the VCSels. However, in the past, some
914 calibration runs have been taken (erroneously) with more
915 than 5000 events, especially the intensity scans where
916 a good precision is needed.
917
918 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
919 photo-electrons for the spline extractor by 1-2% (correctly).
920
921 - callisto: The intercalibration is now done using a full f-factor
922 method instead of a simple update. This makes things slower but
923 more reliable in terms of gain-fluctuations and sudden VCSEL gain
924 changes.
925
926 - callisto: MPedestalY3 now uses the same extraction range as the data
927 as calculated by MPedestalY2
928
929 - callisto: A check of the fraction of allowed unsuitable (10%) and
930 unreliable (30%) pixels has been addded when the conversion is
931 calculated from interleaved events
932
933 - star: fixed a bug which caused MEffectiveOnTime containers not to
934 be written. In the worst case they were skipped almost all, in the
935 best case they were all ok. It depends on how often the new value
936 was assigned just with an event which was skipped later by another
937 task
938
939 - star: new histograms MHPointing and MHRate
940
941 - star: New tab (Currents) displaying the time evolution of the mean
942 DC currents
943
944 - star: New tab (MeanRms) displaying the time volution of the mean
945 Pedestal Rms
946
947 - star: Output now contains MReportStarguider
948
949 - star: Improved muon analysis. Due to the absense of a constant
950 for the gaus fit for arc width and the fact that the arcwidth
951 plot was a histogram instead of a profile the resulting psf
952 became pedestal rms dependant
953
954 - ganymed: added new plot (MHPhi) for wobble mode as described in
955 http://www.astro.uni-wuerzburg.de/results/ringmethod/
956
957 - ganymed: corrects now (correctly?) for the misspointing in
958 May/April 05
959
960 - ganymed: Two new default templates for ganymed.rc are avilable:
961 ganymed_onoff.rc and ganymed_wobble.rc
962
963 - ganymed: The first version of MFMagicCuts has been released
964
965 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
966
967 - ganymed, sponde: There are two new options to determin the number
968 of bins for the signal region (NumBinsSignal) and the number of
969 total bins (NumBinsTotal) in the MHThetaSq histogram
970
971 - ganymed: optimized palettes for MHDisp
972
973 - ganymed: Fixed an important bug when using ThetaSq as fit function:
974 The result for the sigma of the gauss(sqrt(x)) fit was a factor
975 sqrt(2) to large
976
977 - ganymed: The false source plot (MHDisp) is now based on Disp
978 and a background model determined in the first loop is
979 subtracted
980
981 - ganymed: MFMagicCuts are now available in the cvs. The correct
982 solution for the disp ambiguity problem is now calculated using
983 the third moment. The third moment cut therefor is skipped.
984
985 - ganymed: Output now contains "Disp [MParameterD]" which sign is
986 already determined by the third moment along the major axis and
987 so its actual sign is aligned along the major axis of the shower.
988
989 - ganymed: If starguider data is available it is taken into account
990 when calculating the source position. This is especially important
991 for wobble data at high zenith angles and culmination data.
992
993 - ganymed: If available the starguider data is taken into account as
994 good as it is possible without a starguider calibration. To switch
995 it off add
996 MPointingDevCalc.MaxAbsDev: -1
997 to your ganymed.rc
998
999 - sponde: the zenith angle distribution is now weighted instead of
1000 choosen by default. This gurantees higher statistics in the highest
1001 and lowest energy bins. To switch this behaviour off use...
1002
1003 - sponde: now automatically displays the energy threshold
1004
1005
1006
1007 *** Version 0.9.3 (2005/06/03)
1008
1009 - general: MMcEvt now derived from MMcEvtBasic which should
1010 have no influence on compatibility with older camera files
1011
1012 - general: Implemented a new option to MReadReports which allows
1013 to force reading of the first event of some trees (eg. Drive-tree)
1014 before any other tree.
1015
1016 - general: Made a fix to MPointingPosCalc which assumes that the
1017 run-type is real-data if Process is called before ReInit, such
1018 that also the very first Drive-events in a run are treated
1019 correctly.
1020
1021 - shoplot now displays the filename in the title bar of the window
1022
1023 - merpp: new options: --auto-time-start --auto-time-stop which
1024 allow to cut updating with slow-control at the start- or
1025 (previousle --auto-time only allowed: and) stop-time of
1026 the run stored in the runheader.
1027
1028 - callisto: changed default of fgFallTimeHiGain in
1029 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1030 already set as default in callisto_Dec04Jan05.rc
1031
1032 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1033 now changes the filename for new weights automatically for
1034 cosmics, MC and for different calibration colors.
1035
1036 - callisto: a problem with the order of some code cause the
1037 name of the weights file in MPedestalY2 to be ignored.
1038 Wrongly the calibration_UV weights were used instead
1039 of the cosmics weights set in callisto.rc.
1040
1041 - callisto: should allow ct1 pulser data when the color is
1042 explicitly set also for pretty new runs
1043
1044 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1045 to introduce an additional scale factor (should be around 1)
1046 to adapt for slight deviations in different extractors from
1047 the MC calibration. For MC calibrations the scale factor
1048 is fixed to 1
1049
1050 - callisto: MFCosmics should handle very high signals a bit
1051 more accurate now
1052
1053 - callisto: when calculating the mean pedestal rms for different
1054 pixel sizes or sectors also kUnsuitableEvt is now taken into
1055 account - not only kUnsuitableRun
1056
1057 - callisto: '-raw' option is now the default
1058
1059 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1060 This has the advantage that mean values in the calibration (eg
1061 arrival times) are calculated more accuratly.
1062
1063 - callisto: In the resource file callisto_Dec04Jan05.rc
1064 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1065
1066 - callisto: new Hi-/Lo-Gain intercalibration constants
1067 hilocalib_sp1.root and hilocalib_sp1_mc.root
1068
1069 - callisto: changed default for MJPedestalY2.MaxEvents
1070 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1071
1072 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1073 has changed from 9.0 to 6.0. This is necessary to exclude two very
1074 ringing pixels in September which - when kept - destroy the image
1075 cleaning around them (Markus G.)
1076
1077 - callisto: (!) The Muon analysis of all data taken so far has
1078 suggested that different extractors give slightly different
1079 absolute results after calibration, due to there different
1080 handling of the calibration- and cosmics pulse shape. Although
1081 the over all calibration seems to be a bit to pesimistic (or
1082 the MC seems to be a little bit - 3-5% - too much attenuated).
1083 There for correction factors have been introduced which correct
1084 the calibration constants by
1085 0.956937799 for Digital Filter (callisto.rc)
1086 and
1087 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1088 calibration. The main advantage is, that both data types can
1089 be easily analysed together and compared to the same MC sample.
1090 The factors are choosen such, that the reference is now a
1091 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1092
1093 - star: fixed a bug which caused the first bin of the histograms
1094 vs time to disapear in PostProcess. This gave wrong results
1095 on the screen. The output and all following programs not
1096 directly accessing the histograms haven't been affected
1097
1098 - star, ganymed: Made sure that always the first Drive-tree event
1099 is read and Processed before the first data event was read.
1100
1101 - ganymed: implemented the possibility to replace the standard
1102 false source plot with a different one. For example: If
1103 you want to use a Disp based FS plot use the resource:
1104 NameHistFS: MHDisp
1105 For details about the requirements of these plots look
1106 at the corresponding classes
1107
1108 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1109 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1110 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1111 case MAlphaFitter is setup correctly. For On-Only optimization
1112 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1113 RunOn() instead of Run(). For energy estimation MJOptimize
1114 has been replaced by MJOptimizeEnergy
1115
1116 - sponde: The input MC spectrum can now be weighted to fake a
1117 different spectrum. This is done via MMcSpectrumWeight. For
1118 more details see the class description and sponde.rc
1119
1120 - sponde: The paremeter comparsion plots are not scaled by
1121 their entries anymore. Instead the MC plot is scaled by using
1122 the result spectrum of the analysis. If the input MC spectrum
1123 and the result spectrum has different slopes the absolut
1124 normalization is normally wrong.
1125
1126
1127
1128 *** Version 0.9.2 (2005/05/20)
1129
1130 - general: Changed the default paths for calibrated data and image
1131 files. (The implemented access to these files doesn't yet exist)
1132
1133 - general: support for MRunIter has been removed from the job classes
1134 (use the setter functions of MSeqeunce instead)
1135
1136 - general: ProcessFile has been renamed to Process in all job classes,
1137 because ProcessFile is missleading
1138
1139 - general: The storage of the palette in MHCamera is now possible
1140
1141 - general: new bits describing unsuitable and unreliable pixels have
1142 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1143 kDeadPedestalRms, kFluctuatingArrivalTimes
1144
1145 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1146 versions newer than V200404070
1147
1148 - general: support for cc file versions newer than V200504130. Added
1149 support for active loads (MCameraActiveLoad) and central pixel
1150 (MCameraCentralPixel)
1151
1152 - general: added new histograms for image parameters versus size
1153 (MHVsSize)
1154
1155 - general: The eventloop now automatically calls PrintStatistics
1156
1157 - Status Display: Improved support for printing:
1158 + A default can now be set in .rootrc (for more details see
1159 MStatusDisplay::PrintPS)
1160 + A print dialog is opened so that printer and command line
1161 can be canged
1162
1163 - showlog: improved such that it handles different verbosity levels
1164 more accurate now. This mean you can suppress output when
1165 using showlog.
1166
1167 - showplot: improved
1168 + The new graphics formats have been implemented
1169 (pdf, svg, png, jpg and xpm)
1170 + Implemented an interface for printing. Because you can change
1171 the printing command from the command line you can use all
1172 the nice postscript tool. To print a booklet for example call:
1173 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1174 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1175 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1176
1177 - callisto: fixed a bug in the recognition of the calibration bit
1178 pattern. Concerns only intensity calibration. (The strength of the
1179 intensity has been updated in some cases)
1180
1181 - callisto: add a filter against PIN Diode events when running over
1182 calibration runs since some of the recent calibration runs have
1183 been taken with Pin Diode.
1184
1185 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1186 39943, 44833 in the calibration (MCalibColorSet)
1187
1188 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1189 been set to 1e-18 in callisto_Dec04_Jan05.rc
1190
1191 - callisto: in callisto_Dec04Jan05.rc: set value for
1192 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1193 statistics for the calculation of the mean pulse time
1194 of the cosmisc
1195
1196 - callisto: the charge limit in the calibration has been raised
1197 from 2.5 to 4.5
1198
1199 - callisto: new setup read from callisto.rc
1200 + MCalibCalcFromPast.fNumEventsDump
1201 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1202 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1203
1204 - callisto: MExtractTimeAndChargeSpline extractor:
1205 + The integration ranges were shifted by 0.2 FADC slices to the right.
1206 + unreliable handling of floating point values caused different
1207 results on different platform or with different compiler options:
1208 The new algorithm is numerically exact and more accurate because
1209 it doesn't calculate the integration position by multiple times
1210 adding the step-size (which results in numerical uncertanties
1211 exspecially if multiplied with large numbers)
1212 + A lot of fixes have been introduced which effects integrating the
1213 spline at the edges of the valid range. In this case any memory
1214 was randomly accessed. This behaviour can be tested replacing
1215 all MArrayF by TArrayF which perform a range check (but of course
1216 they are a lot slower)
1217 ! No result obtained with the Spline before can be trusted! Due to
1218 random memory access it might by completely random!
1219
1220 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1221 + extraction range in the high gain to 4.
1222 + weights file to cosmics_weights46.dat
1223
1224 - callisto:
1225 + introduce the check for fluctuating arrival times.
1226 + set charge limit to from 2.5 to 4.5
1227 + introduce asymmetric exclusion due to "deviating number of phes":
1228 Default: -9.0 +4.5
1229 + make deviating number of phes unsuitable (see David's findings).
1230
1231 - callisto: fixed the display of unsuitable pixels. The old change
1232 to a real profile in MHCamera broke it.
1233
1234 - callisto: The cosmics filter is used in MJCalibration now
1235 independant of the pulser color (formaly it was used only for
1236 CT1-pulser data). The threshold of number of max empty pixels
1237 has been raised from 2% to 5% in MJCalibration. The maximum
1238 fraction of rejected event is 50% otherwise the calibration has
1239 failed. The filter now ignores unsuitable pixels.
1240 Setup the filter from callisto.rc using "ContCosmics"
1241 (see MFCosmics::ReadEnv)
1242
1243 - callisto: changed default for fgOffsetFromLogain back
1244 from -2.8 to -1.8 in digital filter.
1245
1246 - callisto: for the common extractors
1247 + MExtractFixedWindow
1248 * MExtractTimeAndChargeSlidingWindow
1249 * MExtractTimeAndChargeSpline
1250 * MExtractTimeAndChargeDigitalFilter
1251 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1252 and fResolutionPerPheLoGain
1253
1254 - callisto: Updated the hi-/lo-gain intercalibration constants
1255 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1256 hilocalib_df6.root
1257
1258 - callisto: The default lo-gain extraction window for the
1259 MExtractTimeAndChargeSlidingWindow extractor has been increased
1260 from 6 to 8 to take the stretch of the pusle into account
1261
1262 - callisto (!!!): fixed an important bug in the setting of the
1263 incoming pedestal pointer to the signal extractor extracting
1264 pedestals. This bug caused the pedestals not to be subtracted
1265 correctly in the calibration afterwards. The effect was about 10%
1266 too high conversion factors for the digital filter and the spline
1267 and more than 40% for the sliding window.
1268 The bug existed since end of February! (Markus G.)
1269
1270 - star: added muon support to star. A new tab "MHMuonPar" is
1271 displayed. The lower right plot is an estimate of the point spread
1272 function. A reference value is displayed. To get the real PSF
1273 you must compare with MC. The setup for the muon analysis
1274 is done in star.rc. More informations can be found in
1275 MHSingleMuon and MHCalibParCalc
1276
1277 - star: The weather data is now displayed in star
1278
1279 - star: MEventRateCalc handles the calculation of the event rate more
1280 accurate now in case of the start of a new run inside a sequence
1281
1282 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1283 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1284 changed only minimally
1285
1286 - ganymed: (MJCut and MJOptimize) now displayes the number of
1287 excess events versus size. The energy estimation is done in
1288 MJSpectrum (sponde)
1289
1290 - ganymed: got support for using other variables than Alpha, eg. Theta.
1291 Therefor you need a class deriving from MHAlpha which supports
1292 this variable (one is already existing: MHTheta, which is now the
1293 default in ganymed). It is setup through ganymed.rc
1294
1295 - added a full featured spectrum program (sponde) which reads
1296 ganymed output and monte carlos and compiles a spectrum
1297
1298
1299
1300 *** Version 0.9.1 (2005/04/14)
1301
1302 - Fix bug on the arrival time reconstruction when using Digital
1303 Filter (in some marginal cases (10%) times were reconstructed shifted
1304 by 0.2 slices)
1305
1306 - all executables now return 2 where in previous versions -1 has
1307 been returned (gave problems with shell-scripts)
1308
1309 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1310 also done with a intercalibration input file
1311
1312 - a bug in the time fine adjustment of the digital filter has been fixed
1313
1314 - a lot of small fixes to calling TPad::Divide with a margin==0
1315
1316 - MStatusDisplay now shows the memory usage
1317
1318 - added a memory leak statistic after the eventloop
1319
1320 - MHadronness replaced by MParameterD
1321
1322 - MEnergyEst replaced by MParameterD
1323
1324 - wobble mode can now be switched on from the data-set
1325
1326 - switched on bad pixel detection for a pedestal level
1327 which is more than 5 times the variance
1328
1329 - Fixed default paths to be correct for the new data center
1330
1331 - Fixed handling of drive data. The pointing position in now
1332 copied to MPointingPos inside star for real and MC events
1333
1334 - made sure, that the sequences in a dataset are sorted by
1335 their number to ensure the correct synchronization
1336
1337 - added all resource files necessary to handle spline extraction
1338 of signal for the late 2004 and the early 2005 data
1339
1340 - update the reference lines for the december data
1341
1342 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1343 This is important for the Dec. and Jan. data where the calibration
1344 pulse position changes much.
1345
1346 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1347 filter. This corrects only an defective extraction of the MC at
1348 low-gain signals lower than 90 phes.
1349
1350 - fixed some slowdown in calibrating data with interleaved events from
1351 Jan and Dec. As a workaround made the pretty palette the default.
1352 The inverse Deep Blue Sea has a bug which slows down long calibration
1353 runs a lot.
1354
1355 - implemented new values from new starguider report as defined
1356 in TDAS00-07 V7.1 (eg SkyBrighness)
1357
1358 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1359 in starguider report (If you merpp the same reports with this version
1360 you'll get the correct units (arcmin) but a different result
1361 than with old versions (wrong units))
1362
1363 - Now the status display can also write PNG, JPEG and XPM (other file
1364 formats are still unsupported by root)
1365
1366 - added a lot of scripts and macros in directory datacenter used
1367 for automatic processing
1368
1369
1370
1371 *** Version 0.9 (2005/03/23)
1372
1373 - Calibration is now done autmatically into photo-electrons like
1374 decided by the Collaboration Board
1375
1376 - Reference lines in the display can be read from resource file
1377
1378 - Interlaced calibration events can be handled by callisto
1379
1380 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1381 and applied in callisto.
1382
1383 - class MJCalibTest can be called by callisto
1384
1385 - callisto can now run with three data types: rawdata, rootdata, MC
1386
1387 - added two classes mreport/MReportStarguider.cc and
1388 mreport/MReportStarguider.h for implementing starguider-data
1389
1390 - the output of merpp-update now contains starguider information:
1391 MReportStarguider and MTimeStarguider
1392
1393 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1394 values were lower than they should. This was more visible for high
1395 energy (Size) events.
1396
1397 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1398
1399 - added a new loop to callisto to support the correct extraction of
1400 the pedestal and pedestal rms through the signal extractor
1401
1402 - added class to perform fourier tranformation of a hexagonal structure
1403 (MHexagonalFT)
1404
1405 - added class to perform fourier tranformation of a hexagonal structure
1406 in a tasklist (MHexagonalFTCalc) example: hft.C
1407
1408 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1409 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1410 small pixels, example: extendcam.C
1411
1412 - added possibility to write data to memory (TTree) using MWriteRootFile
1413
1414 - added possibility to read a TTree stored only in memory by MReadTree
1415
1416 - new classes to deal with the interleaved calibration events:
1417 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1418
1419 - implemented filters to callisto to skip calibration events
1420
1421 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1422 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1423 the slices by statistics
1424 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1425 signal extractor without randomization
1426 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1427 with the signal extractor with randomization (extraction window is
1428 randomly fixed)
1429 The three kind of pedestal is not yet implemented (for speed reasons) as
1430 long as nobody really needs it:
1431 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1432 extracted with the signal extractor with randomization
1433
1434 - callisto now finds the pulse position in the data automatically
1435
1436 - implemented data reduction in calibrated data by reducing the precision
1437 of the stored floating point values (pedestal, rms and signal) to
1438 roughly 0.5%
1439
1440 - fixed showplot to make file format conversion (eg. converting a
1441 status display stored in a root file into a postscript file) in
1442 batch mode possible:
1443 showplot -b --save-as-ps[=outfile.ps] infile.root
1444
1445 - Allow class names as part of filter rules, eg
1446 (MFSupercuts) && (MHillas.fSize>100)
1447
1448 - fixed a lot of stuff to allow all programs to process MonteCarlo
1449 camera files.
1450
1451 - enhanced possibility to debug reading of resource file
1452
1453 - MDataChain should handle priorities of operator more
1454 accurate now
1455
1456 - completely revised the container in which the signal is stored
1457 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1458 * the new implementation is faster and
1459 * needs less storage space
1460
1461 - FIRST version which can process Monte Carlos through the
1462 whole chain of programs (callisto, star, etc)
1463
1464 - implemented new image parameters for the border length of
1465 the shower image (MNewImagePar2)
1466
1467 - implemented wobble-mode in ganymed
1468
1469 - new class (MJOptimize) taking care of all optimization processes
1470
1471
1472
1473 *** Version 0.8.6 (2004/10/05)
1474
1475 - New combined signal and time extractor
1476 MExtractTimeAndChargeDigitalFilter
1477
1478 - The Report for the trigger section in the CC run summary has been
1479 updated, and now the IPRs (Individual Pixel Rates) are available.
1480
1481 - new macros for database interaction: filldotrun.C, filldotrbk.C
1482
1483 - added new program which can convert colored output which was redirected
1484 into a file back into colored text (for example to display it with
1485 more): showlog
1486
1487 - added new program to display an MStatusArray of plots (stored with
1488 MStatusDisplay) from a file: showplot
1489
1490 - Added support for Sequences (MSequence). Sequences are blocks of run
1491 files containing the same calibration and belonging to the same
1492 source
1493
1494 - Added a new task (MTaskEnv) which can be used in setup files to switch
1495 between different tasks (for example to choose a signal extractor)
1496
1497 - Implemented automatic file splitting in MWriteRootFile
1498
1499 - After image cleaning an island index is assigned to all used pixels.
1500 The index corresponds to the order of the islands in size.
1501
1502 - added a cleaning which takes signal height _and_ arrival time into
1503 account: probability cleaning (for more details see MImgCleanStd)
1504
1505 - added a cleaning which takes takes the absolute number of photons
1506 times the area ratio as cleaning level
1507 (for more details see MImgCleanStd)
1508
1509 - Changed calculation of image parameters such, that it can be done
1510 for all used pixels or the pixels with a defined island index only
1511
1512 - implemented new image parameters displaying the number of islands,
1513 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1514
1515 - event display in executable changed to support also calibrated files
1516 (done with MJCalibrateSignal)
1517
1518 - added program doing the calibration and the signal extraction
1519 and signal calibration: callisto Most part of the setup is done
1520 by a resource file: callisto.rc
1521
1522 - implemented support for pixels with negative IDs (Raw file format
1523 version 4)
1524
1525 - implemented an new option in merpp (--auto-time) to get the time
1526 range for cc and/or caco data from the run header of the raw data
1527
1528 - New star-program (star and MJStar). Taking calibrated data from
1529 callisto/MJCalibrateSignal as input. The setup is done through
1530 a resource file: star.rc
1531
1532 - Added possibility to setup the eventloop in the mars-executable
1533 Camera Display by a resource file: mars.rc
1534
1535 - The the mars-executable Camera Display can now also read
1536 calibrated data files written by callisto/MJCalibrateSignal
1537
1538 - Added a new class which can calculate the source position in
1539 the camera from a pointing model known to be correct and
1540 the pointing model used for observations (MSrcPosFromModel)
1541
1542 - added a new version of the class calculating the effective on-time
1543 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1544 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1545 MHTimeDiffTheta.
1546
1547 - added the possibility to count how often a signal is above (or
1548 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1549 can replace MHTriggerLvl0)
1550
1551 - added ore convinient ways to set the axis-titles of your histograms
1552 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1553 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1554
1555
1556
1557 *** Version 0.8.5 (2004/08/06)
1558
1559 - new Signal Extractors: MExtractFixedWindowSpline
1560 and MExtractAmplitudeSpline
1561
1562 - implementes interleave in merpp to be able to merpp parts of a file
1563
1564 - implemented force-functionality to merpp
1565
1566 - star display to display star catalogs (MAstroCatalog)
1567
1568 - star display to 'mirror' stars to the camera (MAstroCamera)
1569
1570 - implemented a new cleaning option which allows cleaning scaled with
1571 the real ratio of the rms depending on the pixel size, not only the
1572 square root of the pixelsize (MImgCleanStd, MCameraData)
1573
1574 - removed obsolete MBlind* classes
1575
1576 - Signal extractor taking the AB flag into account implemented (this makes
1577 an odd number of slices for signal extraction possible
1578 (MExtractSignalABcorr)
1579
1580 - implemented a class extracting the pedestal from the raw-data (events)
1581 itself using empty lo-gain (MpedCalcFromLoGain)
1582
1583 - Added mean values to MPedPhotCam
1584
1585 - Added Makefile for Darwin (this OS is NOT officially supported!)
1586
1587
1588
1589 *** Version 0.8.4 (2004/04/19)
1590
1591 - new fast arrival time extractor using cubic splines:
1592 MExtractTimeFastSpline
1593
1594 - implementes multi-argument support in MDataChain
1595 ("pow(a, b)")
1596
1597 - implemented double reference support in MDataChain
1598 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1599
1600 - added support in MF for expressiond like
1601 "MHillas.fWidth<2*<MHillas.fLength"
1602
1603 - MDataChain is now able to support variables like [0], [1], ...
1604 which can be used in fit functions as parameters. The interface
1605 is implemented through the new virtual function
1606 MParContainer::SetVariables
1607
1608 - added new class MArrivalTimeCam/MArrivalTimePix:
1609 Storage containers to hold the ArrivalTime of the camera/pixel
1610
1611 - added new classes for the calibration of relative arrival times:
1612 MCalibrationRelTimePix and MCalibrationRelTimeCam
1613
1614 - added new classes to extract the signal of the blind pixel and the
1615 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1616
1617 - added new classes for the bad-pixels treatment (MBadPixels*)
1618 which are more powerfull than the old ones (MBlindPixel*)
1619 and will replace them.
1620
1621 - added filter against cosmics: MFCosmics
1622
1623 - added new class MArrivalTimeCalc2:
1624 Calculates the arrival time as the signal weighted mean of the time
1625 slices in the maximum window
1626
1627 - added a new macro call pointspreadfucntion.C that fits with a 2D
1628 gaussian the DC spot for an star. It gives you the RMS of
1629 the PSF and the center of the star, very useful for misspointing
1630 studies.
1631
1632 - added support for multi-telescope camera files. Added classes
1633 MStereoCalc and MStereoPar, classes to calculate and store shower
1634 parameters calculated from the data of two telescopes, for the MC
1635 studies regarding the MAGIC clone.
1636
1637 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1638 MC data calibrated in photons instead of ADC counts.
1639
1640 - added three macros to show the calibration and analysis chain of
1641 MC data. The macro starmc.C does both calibration and analysis, producing
1642 an output containing Hillas parameters for each event. The macro
1643 mccalibrate.C does just the calibration and writes out a file containing
1644 pixel information in photons instead of FADC data. The macro starmc2.C
1645 reads in such a file and produces an output with Hillas parameters.
1646
1647 - added MPedPhotCalc to compute pedestals in units of photons, see
1648 macro pedphotcalc.C
1649
1650 - added all class to perform the calibration, see macro calibration.C
1651
1652 - added class MFFT to perform Fast Fourier Transforms
1653
1654 - added class MSimulatedAnnealing to perform simulated annealing
1655 minimizations
1656
1657 - added new macro bootcampstandardanalysis.C which holds the skeleton
1658 of the analysis chain discussed in the december bootcamp.
1659
1660 - added support for DAQ raw data file format V2
1661
1662 - implemented an arbitrary time stamp for the events from raw-data
1663 files with file version<3. It is calculated from the run number,
1664 the date of start and the FADC clock tick from the first module
1665
1666 - implemented the correct decoding of the event time-stamp
1667 coming from the DAQ for raw-data files with file-version>2
1668
1669 - added a new classes storing the pedestals in units of photons:
1670 MPedPhotPix, MPedPhotCam
1671
1672 - added support for DC current files from the camera control
1673
1674 - added support for start- and stop-time when merpping report files
1675
1676 - added MReportCC storing the weather data from the CC-REPORT
1677
1678 - added class to fill trainings and test matrices (MTFillMatrix)
1679
1680 - added a filter performing a software trigger (MFSoftwareTrigger)
1681
1682 - Added classes to perform parts of the standard analysis (Jobs):
1683 + MJPedestals
1684 + MJCalibration
1685 + MJExtractSignal
1686 Note: All of them are preliminary!
1687
1688 - Added Iterator to iterate over files giving only the run-number
1689
1690 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1691 the evolution of a sector vs time
1692
1693
1694
1695 *** Version 0.8.3 (2003/12/05)
1696
1697 - adapted Random Forest classes to allow the use with MC
1698 multi-telescope files which can be produced with the coming
1699 camera version 0.7.
1700
1701 - added classes to read and interprete central control report files
1702 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1703
1704 - enhanced merpp (the executable) to support .raw and .rep files.
1705
1706 - added classes for light calibration (MCalibration* and
1707 MHCalibration*) by Markus Gaug. Further work has to be and will
1708 be done soon.
1709
1710 - Added a preliminary 'synchronizer' (MReadReports) which will
1711 replace MReadMarsFile as soon as it is finished.
1712
1713 - Added a tutorial macro demonstrating how report files are merpped
1714 and how they can be read from the root file in the correct order
1715 of time (readrep.C)
1716
1717 - Added a generalized histogram (similar to MH3) called MVsTime
1718 which allows to plot variables (or rules - MDataChain - of
1719 variables) vs time. For an example have a look at tempvstime.C.
1720
1721 - Changed the name of the event trees:
1722 + Events --> Events
1723 + PedEvents --> Pedestals
1724 + CalEvents --> Calibration
1725
1726 - changed name of MTime in the event trees from MRawEvtTime to MTime
1727
1728 - added displaying the sector indices to the mars event display
1729
1730 - Magic Online Analysis (MOnA) implemented in a first version
1731 (see mona.cc, MOnlineDump and MOnlineDisplay)
1732
1733 - added classes to calculate event rate
1734 (preliminary: MEventRateCalc, MEventRate)
1735
1736 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1737
1738 - added classes dealing with the telescope pointing position (MPointing*)
1739
1740 - implemented the 'final' Mars time stamp based on some experiences with
1741 the new 'Synchonizer'
1742
1743
1744
1745 *** Version 0.8.2 (2003/11/10)
1746
1747 - accelerated standard analysis by a factor of 6-8 ...
1748 + doing precalculations in MGeomCam for the pixel area ratio
1749 + creating a look up table for the single pixels in MCerPhotEvt
1750
1751 - added task to calculates weights in case you want to 'change'
1752 the energy spectrum of a monte carlo file
1753 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1754
1755 - added a new executable star which implements the
1756 star.C macro as precompiled executable. Currently a flexible
1757 setup is not possible, but a 'input card' setup will follow.
1758
1759 - Starting to implement Multi-Telescope-Support based on the
1760 upcomming camera version 0.7. The base for a general support
1761 is implemented and the star-functionality is proven to work.
1762
1763 - Replaced Event-Display in and Camera-Display in the Mars GUI
1764 executable by a more convinient display base on MStatusDisplay.
1765
1766 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1767
1768
1769
1770 *** Version 0.8.1 (2003/10/20)
1771
1772 - added signal subtraction for pure on data by means of fitting
1773 the background in the off region or by performing a combined
1774 signal/background fit. Provides necessary histograms for
1775 obtaining energy spectra and a light curve.
1776
1777 - added classes to perform and study the selection of the
1778 2nd Level Trigger on MC data (example in triglvl2.C macro)
1779
1780 - added pedestal calculation
1781
1782 - implemented "democratic cleaning" (tail cut value proportional
1783 to pixel area) according to Wolfgang's suggestion.
1784
1785 - added Sigmabar treatment (calculation and basic histogramming)
1786
1787 - added basic routines to apply padding
1788
1789 - added first implementation of MARS-based source visibility plotter
1790 (needs to be linked against slalib, preliminary version)
1791
1792 - enhanced functionality of data chains: random numbers, conversion
1793 functions and access to MHMatrix objects
1794
1795 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1796 numbers under certain circumstances (runs with 0 events included)
1797
1798 - fixed a bug in the general filter MF (didn't work on some systems
1799 at all)
1800
1801 - fixed a bug in chaining files, which caused the analysis to crash or
1802 ignore files
1803
1804 - implemented more geometry classes describing the parameters used
1805 to simulate the PMT camera
1806
1807 - added new Monte Carlo classes containing the setup of the different
1808 programs in the MC chain.
1809
1810 - added a (preliminary) general task to evaluate chi-square of a given
1811 parameter in an eventloop.
1812
1813 - first implementation of a container describing the observatory
1814 location (Long, Lat, etc)
1815
1816 - added Random Forest - method for g/h-separation
1817
1818 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1819 (this means, that it is compiling, but not yet fully tested)
1820
1821 - added a new status display which can show the present status
1822 of histograms while an eventloop is running (MStatusDisplay,
1823 an example can be found at status.C)
1824
1825 - reorganized directories:
1826 classes describing the image --> mimage
1827 classes containing Monte Carlo Histograms --> mhistmc
1828 classes for Random Forest method --> mranforest
1829
1830 - added (event-)weights to fill histograms
1831
1832 - colors in logging output to screen
1833
1834 - changes to the Image Parameter declaration:
1835 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1836 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1837 + MHillasExt now derives from MParContainer instead of MHillas
1838 --> Files written with the old definition are more or less unreadable
1839
1840 - reading of reflector files
1841
1842 - display data from reflector files in the camera
1843
1844 - implemented currents (and display them in the camera)
1845
1846 - logarithmic scale in camera
1847
1848 - added class to iterate through directory contents (MDirIter)
1849
1850
1851
1852 *** Version 0.8 (2002/11/18)
1853
1854 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1855
1856 - corrected 48(!) wrong entries in the Next Neighbor table of the
1857 Magic Camera (all in the inner part of the outer ring, mostly
1858 missing a single NN)
1859
1860 - Fixed a bug in the table describing the Next Neighbours of the
1861 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1862 have any neighbour)
1863
1864 - changed trigrate.C: now it calculates the pure NSB triggers from
1865 a camera file (generated with no showers), so there is no need
1866 to introduce them by hand in the BgR array (for more details
1867 please ask Abelardo)
1868
1869 - added MHHadronness (and MHadronness) as a general facility to evaluate
1870 the quality of a gamma-hadron seperation method
1871
1872 - changed MWriteAsciiFile to accept rules (MDataChain)
1873
1874 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1875 must be replaced by calles to MWriteAsciiFile::AddColumn and
1876 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1877 changed.
1878
1879 - Implemented generalized event-matrices (one row per event)
1880 (MHMatrix)
1881
1882 - implemented the one dimensional composite probabilities
1883 (MHCompProb, MCompProbCalc, comprob.C)
1884
1885 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1886 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1887
1888 - Added a camera display displaying the pixel numbers to the
1889 event display gui.
1890
1891 - Added Monte Carlo Informations to event display gui
1892
1893 - Changed the camera display to display the pixel numbering
1894
1895 - Added three buttons to the camera display to change the palette
1896
1897 - Added the number of used and core pixels after image cleaning
1898 to MHillas
1899
1900 - Changed the algorithm used in MHillas according to TDAS 02-03
1901
1902 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1903
1904 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1905
1906 - Added fCosDeltaAlpha to MHillasSrc
1907
1908 - The numbers of photons used to calculate fConc and fConc1 in
1909 MHillasExt are now scaled with the pixel size, so that one get
1910 a four times smaller value for the bigger pixels in the outer ring.
1911
1912 - added new task to smooth the camera contents (MCameraSmooth)
1913
1914 - added possibility to use interpolated pixel values for blind pixels
1915 instead of removing it completely from the analysis
1916
1917 - Implemented the possibility to save the whole eventloop with
1918 its setup to a file. This information can be read and from
1919 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1920 and MEvtLoop::MakeMacro. If you find something not working, please
1921 report - this stuff is still in a beta phase.
1922
1923 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1924 file having crab starfield, but also for all following files - fixed
1925
1926 - MTaskList::PrintStatistics can now be instructud to print also the
1927 title, too: use PrintStatistics(0, kTRUE)
1928
1929 - Changed the image cleaning so that pixels with to many 'used'
1930 neighbors are left used (to get rid of 'holes' in events)
1931
1932 - Introduced more output to the camera displays
1933
1934 - Added an array of histograms (eg one hist per run), MHArray
1935
1936 - Added a _preliminary_ version of the reader for CT1 PreProc files
1937 (MCT1ReadPreProc)
1938
1939 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1940 (thanks to Raquel)
1941
1942 - added the first energy estimator (MEnergyEstParam, estimate.C,
1943 estfit.C) using a parametrization
1944
1945 - Added some new Monte Carlo paremeter containers used to store
1946 setup information from the MC chain (MMcConfigRunHeader,
1947 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1948
1949
1950
1951 *** Version 0.7 (2002/04/30)
1952
1953 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1954 the pedestal mean value was saved incorrectly. For files from
1955 this versions we substract 0.5 from the pedestal mean.
1956 WARNING: This may effect your results, so don't wonder...
1957
1958 - First implementation of an algorithm using only triggered events
1959 for the collection area calculation
1960
1961 - Ascii Output can now also be used for parameter containers which
1962 doesn't overload MParCointainer::AsciiWrite
1963
1964 - The Ascii Output is now also capable of writing single data members
1965 of one container
1966
1967 - You are now able to change the order of the values written to the
1968 ascii file
1969
1970 - You can now specify a conversion factor for each data member written
1971 to an ascii file. This may be usefull to change the units of the
1972 data member (eg. degrees instead of millimeters in case of the
1973 hillas parameters)
1974
1975 - Replaced old MHillas by a new structure which allows you to extend
1976 the parameters stored in MHillas very easily:
1977 see MHillas and MHillasExt
1978
1979 - Added classes to handle source dependancy of image parameters:
1980 see MHillasSrc
1981
1982 - Added container (MBinning) to have a standard input for the binning
1983 in different histograms (eg. the Energy bins should be the same in
1984 all histograms)
1985
1986 - Changed Hillas histograms from mm to deg
1987
1988 - Added the flexible binning to the hillas histograms
1989
1990 - Added a filter for the alpha parameter (MFAlpha)
1991
1992 - It is now possible to write single data members of a class object to
1993 an output stream instead of the whole container only
1994
1995 - Added a generalized filter for a data member:
1996 MFDataMember filter("MHillas.fWidth", '<', 0.5);
1997
1998 - Added a generalized Filter parser for more difficult filter rules
1999 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2000
2001 - Added new Monte Carlo histograms:
2002 MHMcEnergyImpact and MHMcEfficiency
2003
2004 - Added many new histograms needed for the flux calculation.
2005
2006 - Added a generalized histograms which can fill and show up to three
2007 data members in either a one-, two- or three-dimensional histogram, eg:
2008 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2009
2010 - Added:
2011 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2012 * calculation of <Theta> as a function of time (MHThetabarTime)
2013 they are needed in the flux calculation in
2014 order to select for a given bin in Theta (or time) the appropriate
2015 effective collection area, which is assumed to be given as a function
2016 of Theta and the true energy
2017
2018 - Added calculation of the migration matrix in the energy
2019 (MHMcEnergyMigration):
2020 the migration matrix describes the migration from the true (E_true)
2021 to the estimated energy (E_est); it is needed to determine the
2022 distribution of E_true from the measured distribution of E_est
2023 by unfolding
2024
2025 - changed the color palette in the camera display to DeapSea.
2026
2027
2028
2029 *** Version 0.6 (2002/01/15)
2030
2031 - Introduce the option of disable pixels (MBlindPixels and
2032 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2033 able to deal with Star Field NSB.
2034
2035 - Fixed a bug in the pedestals substraction
2036
2037 - Introduced verbosity levels
2038
2039 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2040
2041 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2042 work correctly (thanks to Abelardo)
2043
2044 - Introduced correct treatment of the diffuse Night Sky Background
2045 and NSB (MMcPedestalNSB)
2046
2047 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2048
2049 - Introduced MMcRunHeaders which contains monte carlo run informations
2050
2051 - Added a 'Print'-Task (MPrint) which calls the Print function
2052 of a parameter container for each event
2053
2054 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2055
2056 - changes to be more efficient with root 3.02/06
2057
2058 - root 3.02/06 fixes:
2059 + the memory leak when reading MRawEvtData
2060 + loosing more time than necessary to update the progress bar
2061
2062 - MWriteAsciiFile is now capable of writing more than one container
2063 in a line. For example: To be able to write Monte Carlo and
2064 Hillas values (energy and alpha) in one line.
2065
2066
2067
2068 *** Version 0.5 (2001/11/06)
2069
2070 - Added new GUI functionality (Analysis)
2071
2072 - Added a camera display to be able to display events in the camera
2073 together with the calculated hillas ellipse
2074
2075 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2076 object at any state of the analysis, so that the output are several
2077 states
2078
2079 - Fixed a bug in the collection area error calculation
2080 (Thanks to Ciro and Abelardo)
2081
2082 - Fixed a bug which causes merpp to crash in some environments
2083
2084 - Implemented auto enabling scheme for Branches to speed up reading
2085 a lot (see MReadTree and MTask)
2086
2087 - Fixed a bug in the Histogram classes which caused histograms to
2088 be written to a file by MWriteRootFile without request
2089
2090 - changed the object I/O from the old stylish root I/O to the new
2091 'auto evolution scheme' This was done only for classes which are not
2092 yet used in Monte Carlo files, so that these files are still readable.
2093
2094 - Added support for a progress bar in MEvtLoop and MReadTree
2095 (see the Analysis Window in Mars for an example)
2096
2097 - Fixed a bug in the package creation which disturbed the conversion
2098 between a mars version unpacked from a tar file and the repository.
2099
2100 - Changed the code to writer merpped (converted into root format)
2101 raw files, to get faster (around 10%)
2102
2103
2104
2105 *** Version 0.4 (2001/09/20)
2106
2107 - This release is made to compile on a root version >= 3.00
2108
2109 - Fixed a bug which causes MReadTree to read the first file only
2110
2111 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2112
2113 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2114
2115 - Added a task to write several container to a root file (MWriteRootFile)
2116
2117 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2118
2119 - Added calculation of the collection area (MMcCollectionAreaCalc)
2120
2121 - fixed some bugs in the Hillas calculation
2122
2123 - added filters to be able to control the task execution dependent on
2124 a parameter (for example: the number of level 1 triggers in a MC-file)
2125
2126
2127
2128 *** Version 0.3 (2001/04/23)
2129
2130 - Many demo macros added
2131
2132 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2133
2134 - Hillas Calculation added
2135
2136 - Standard image cleaning available
2137
2138 - MReadTree is now able to handle more than one file
2139 (Remark: of the same structure)
2140
2141 - Now we are able to display events in a first version of the
2142 Camera event display. To do this we must run the macro
2143 "macros/readCT1.C" to read data from CT1.
2144
2145
2146
2147 *** Version 0.2 (2001/01/24)
2148
2149 - First Implementation of a Gui to read the raw data. Start the
2150 gui with the command mars.
2151
2152
2153
2154 *** Version 0.1 (2000/12/20)
2155
2156 - First official release 0.1
2157
2158 - Changes:
2159
2160 + changed calling style of MRawPixelIterator from do...while to
2161 while-loop
Note: See TracBrowser for help on using the repository browser.