source: trunk/MagicSoft/Mars/NEWS@ 8387

Last change on this file since 8387 was 8387, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 87.1 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - general: The new class MGeomCamDwarf contains the camera geometry
6 for our prefered Dwarf camera and can be used to create general
7 geometries of roundish or hexagonal cameras.
8
9 - mars: The default cleaning is now Abolsute 8.5/4.0.
10
11 - mars: The resource file mars.rc now contains examples for MUX data
12
13 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
14 data containing only 10-bit information is still cooked down to
15 8-bit, by cutting away the lowest 8-bit.
16
17 - merpp: When reading raw data the data is now stored in a single
18 array. The lo-gain array is obsolete. The interface stays the same.
19
20 - callisto: Improved binning for the pulse position check histogram
21
22 - callisto: The code calculating the pulse position checknow takes
23 the pedestal into account
24
25 - ganymed: The output files now contain run- and event-number for all
26 events, accessible as RunNumber.fVal and EvtNumber.fVal
27
28 - ganymed: Added a plot showing the source position in the camera also
29 for wobble mode
30
31
32
33 *** Version 1.0 (2007/02/16)
34
35 - database: Website to plot values from the database has been added.
36
37 - database: The rate of spark events as found by star is now kept
38 and the rate after cleaning is now with spark events subtracted
39
40 - general: The changes to the interpretation of phrases lead to
41 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
42
43 - general: Added example files how you can create your own calendar
44 (eg. as christmas present) with Mars. Just run
45 root macros/tutorials/calendar.C
46
47 - general: Added a possibility to display grouped data in the plotdb.C
48 macro (and similar macros). This allows to plot hourly, nightly,
49 weekly, monthly and yearly averages.
50 For more details see the plotall function of the macro
51
52 - general: fixed the error display of the camera display. It showed
53 wrong results.
54
55 - general: fixed a memory leak when reading many MStatusDisplays
56
57 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
58 between a spherical and a parabolic mirror
59
60 - callisto: We have a new pulse position check which takes the properties
61 of the extractor automatically into account. So no need to set
62 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
63 left is done. If possible the lo-gain extraction start and hi-gain
64 extraction end is changed accordingly. If no proper extraction range
65 can be set (hi-gain too much to the left) an error is raised.
66
67 - callisto: New swapped pixels have been found and corrected
68
69 - callisto: Redone the signal extraction this includes:
70 + Unified the algorithms to extract the pedestal for all pedestal
71 extractions done
72 + Unification of hi- and lo-gain into one array
73 + Unification of hi- and lo-gain extraction for Spline and
74 Digital Filter (means now exactly the same algorithm is used,
75 not a copy-and-pasted one)
76 + Store pedestal subtracted data in a common place
77 + Improved extraction algorithms. If the algorithms search a
78 maximum but don't find one they don't return the maximum anymore
79 + Improved the extraction such that a information for signal
80 and time which is consistent is returned
81 + replaced the numerical spline with a (not slower) analytical
82 solution
83 + Lowered the saturation limit from 250 to 245 to make sure that
84 we are far away in all pixels from problems with the clock-noise
85 + The start of the lo-gain extraction is calculated from the hi-gain
86 arrival time. In case of saturation an estimation is used.
87 + the hi-gain window was extended to slice 16. This allows extraction
88 of very late pulses in single pixels or of huge hadron showers.
89 + Now uses the lo-gain extraction range for pedestal extraction,
90 not the hi-gain range in the lo-gain
91
92 - callisto: New hi-/lo-gain calibration constants have been produced
93 for all periods from the statistic of the whole period. They are
94 now used automatically depending on the periods. The old constants
95 where deviation in avarega about 2%-3%. The constants are very
96 stable from period to period (<<1%) except for exchanged channels.
97 In a few cases the constants used so far were off by 1%-2% (maybe
98 temperature effects?)
99
100 - callisto: To gain obsolete space we do not write the
101 MPedestalFundamental anymore. Also calibration and bad pixel
102 treatment is not done for it anymore because it has never been used.
103
104 - callisto: Fixed a bug in the seuqence handling which caused the
105 light condition to be ignored
106
107 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
108 basically the same as "Cleaned" but the distribution devided into
109 the events fullfilling a spark cut or being rejected by it.
110 This cut can be changed from star.rc (see example inside) by
111 the "SparkCut" directive
112
113 - star: Star displays now the average individual pixel-rate (IPR) versus
114 time and the average discriminator threshold (DT) of all pixels.
115
116 - optim: fixed a problem with the optim-macros which was due to a bug
117 in the new phrase parsing
118
119 - ganymed: To get a nice FalseSource plot (instead of the all-information
120 debug plot displayed as a standard plot) use the context menu
121 somewhere between the two upper plots, click on "DrawNicePlot"
122 and enjoy the result. (It is the same context menu which contains
123 the other options)
124 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
125
126 - ganymed/optim/train: The cut program, trainings- and optimization
127 macros could run with less files found than expected from the
128 sequence-files. No the execution is stopped in this case.
129
130 - ganymed: now stores the dataset in the output file with all information
131 contained (as sequence number, sequence path, data path) so that the
132 used dataset file can be recreated complete from the output
133
134 - sponde: now also allows the uasge of random forest
135
136 - sponde: added a plot showing the cut efficiency
137
138 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
139 errors (eg. effecting the collection area) because the errors of the
140 two histograms were swapped in the calculation, which makes a difference
141 in the case the histograms contains weighted events. Aditionally the
142 totalarea was incorrectly taken into account, which results in too small
143 errors, which makes a difference at low statistics were the errors
144 or the collection area dominate.
145
146
147
148 *** Version 0.10.3 (2006/10/23)
149
150 - database: Implemented ObservationMode flag in websites.
151
152 - database: For sequences there is now also the stoptime available on the
153 websites.
154
155 - database: Removed ManuallyChanged flag from sequence-info websites,
156 as it is not needed anymore with the new sequence building algorithm.
157
158 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
159 Class for calculation of confidence intervals (upper limits).
160 Use model 3 or 4 for upper limit calculation for MAGIC observations.
161 Please read the class instruction of TRolke for more information.
162
163 - general: The programs now return 0xfe if the requested resource file
164 doesn't exist.
165
166 - general: Errors comming from root itself are now not output to
167 stderr anymore but to our default (colored) log-stream.
168
169 - general: Changed the interface to TFormula such that now everything
170 is parsed by TFormula, which should allow to use phrases even
171 without paranthesis correctly parsed.
172
173 - callisto: replaced the AdHoc number of effective integration slices
174 in the digital filter by an average of the correct number, averaged
175 over all possible set of weights. This also gives correct numbers
176 for the lo-gains which were totally wrong before.
177
178 - callisto: drastically reduced memory consumption by not storing
179 all intermediate calibration results in memory anymore (we might
180 write them into a file in the future)
181
182 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
183 debug plot displayed as a standard plot) use the context menu
184 somewhere between the two upper plots, click on "DrawNicePlot"
185 and enjoy the result. (It is the same context menu which contains
186 the "DrawAll" option)
187 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
188
189
190
191 *** Version 0.10.2 (2006/10/15)
192
193 - general: changed the building of the sequence files such, that
194 the source-/project name in case of wobble-sources is not the
195 source/project of the first data run anymore but the new generalized
196 wobble source/project
197
198 - general: Added some functions to MAstro to calculate sun and
199 moon properties
200
201 - general: Added two new macros (starvisday.C and starvisyear.C)
202 which allow to plot the visibility of several stars in one day
203 or of one star along one year
204
205
206
207 *** Version 0.10.1 (2006/10/11)
208
209 - general: HTML logging output was distorted... fixed.
210
211 - general: Changed the writing of the sequencefiles such that only
212 as many pedestal files as giving at least 1000 pedestal events which
213 are nearby the first calibration run are used as pedestal runs
214
215 - sponde: In the calculation of the collection area(s) and the
216 distribution for MOnte Carlo and estimated energy the error
217 calculation was wrong because root didn't take the errors
218 properly into account... fixed.
219
220
221
222 *** Version 0.10 (2006/10/10)
223
224 - general: all executables now check consistency of the root version
225 installed with the root version used for compilation. The return
226 code in this case is 255.
227
228 - general: The algorithm to build seqeunces has been redesigned
229 completly. It is now more flexible in terms of a resource file
230 resources/sequences.rc which can be used to partly overwrite
231 the default algorithm and defined the important part of the
232 algorithm. It also takes correctly into account several ways
233 of taking wobble-data. Currently the new algorithm doesn't take
234 the number of pedestal events anymore into account (so a sequence
235 could have much less than 1000 pedestal events and data runs are
236 no-more used instead)
237
238 - general: a lot of small changes to make the code compatible with
239 root 5.12/00 and gcc 4.1
240
241 - general: Fixed some warnings thrown if more warnings are switched
242 on in the compiler
243
244 - general: Added a function to MMath which returns the Median of
245 the distribution abs(y[i]-median) but at 68:32 division instead
246 of 50:50, which is somehow the median counterpart of the rms.
247
248 - general: MAstroCatalog allows now to read calatog files (as bsc5)
249 even if they are compressed with gzip (recommended compression
250 is with "-1")
251
252 - showplot:
253 + batch mode creation of image files now works with root 5.12/00
254 + added support for writing bmp (though it never produces
255 bmp which can be read by programs like xv or gimp)
256 + added support for xml
257 + added new option to start the display with a different size, by
258 --display-width=nnn or --display-height=nnn
259 + added options to define the canvas size when the display is started
260 --canvas-width=nnn or --canvas-height=nnn
261 the option can also be used for batch-mode conversion
262 + added an option which automatically fits the display size to the
263 desktop-size: --auto-size
264
265 - merpp: didn't recognize files with the extension .raw.gz - fixed.
266
267 - merpp: allow the reports to have 1000ms due to a bug in the camera
268 program.
269
270 - callisto: New swapped pixels have been found and corrected. For
271 details see MRawRunHeader::FixAssignment()
272
273 - callisto: Callisto now raises an error if one of the input files could
274 not be opened.
275
276 - callisto: In some rare cases it could happen that in the signal
277 extraction of the digital filter the extractor returned nonsense
278 results due a wrong initializion of a variable (this happens in
279 cases in which the extracted signal is exactly zero or the
280 digital filter couldn't slide because of a too small extraction
281 window, which could happen in the lo-gain extraction)
282
283 - callisto: The lo-gains have been marked as valid in some cases
284 when they got not extracted at all (deltsumlo=deltatimelo=0) because
285 the allowed extraction range (fLoGainLast-fLoGainFirst) was
286 smaller than the number of slices (fLoGainWindowSize) needed
287 by the lo-gain extractor
288
289 - callisto: Updated absolute calibration constants (muon calibration)
290
291 - callisto: fixed a bug which caused the hi-gain saturation not
292 to be handled properly in the spline (the position of the
293 saturation was calculated incorrectly)
294
295 - callisto: fixed a bug which gave weird results if hi- _and_
296 lo-gain could not be extracted properly. In some cases hi-
297 and lo-gain have not been extracted at all and the random result
298 got calibrated. In other cases the hi-gain was saturating and the
299 lo-gain has not been extracted. For this a completly arbitraty
300 scale factor was applied to the result from extracting the
301 charge of the saturating hi-gain.
302
303 - callisto: improves handling of extracted signal if lo- and/or
304 hi-gain could not be extracted properly. If no appropriate
305 calibration of either the signal or the arrival time is possible
306 the pixel is now markes as unsuitable instead of estimated.
307
308 - callisto: Fixed a problem in the spline extraction which gave
309 weird results if the signal was extracted from the first (and
310 highest) slice (as a workaround extraction from the first
311 slice has been forbidden)
312
313 - callisto: Fixed a bug regarding the use of the QE which doesn't
314 effect the result because the default is used anyhow.
315 (The bug was there since 14/07/2005)
316
317 - callisto: Changed the default for fgLoGainStartShift to -2.4
318
319 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
320 factors to be always 10 for all pixels as soon as the first
321 calibration update has happend.
322
323 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
324 was off by more than one slice (which gives wrong values for
325 pixels which have saturated the hi-gain) This was a problem
326 mainly for timing studies, not so much for the automatic standard
327 analysis. Also the values for the Spline have been changed slightly:
328 + Digital Filter from 1.70 to 0.95
329 + Spline from 1.39 to 1.30
330 The numbers were sorted out by an extensive test in the
331 test-database.
332
333 - callisto: Removed the tab showing the average calibrated arrival
334 time. It never gave useful information.
335
336 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
337 lo-gain pulse for data pulses if hi- and lo-gain have saturated
338 and both were extracted because the hi-gain was above the
339 LoGainSwitch.
340
341 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
342 lo-gain pulse position (after application of LoGainOffset, which
343 means in the ideal case it is 0) for data pulses if hi- and lo-gain
344 have saturated and both were extracted because the hi-gain was above
345 the LoGainSwitch.
346
347 - callisto: After extensive tests a new threshold level for determination
348 of the pulse position has been found at 50phe. This is due to the
349 fact that for lower pulses the arrival time changes its average
350 behaviour dramatically. It tends to the average of the extraction
351 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
352
353 - callisto: Added two more plots to the calibration part. The average
354 extracted signal and the average extracted arrival time as
355 extracted by the signal extractor (This can help debugging problems
356 because it doesn't involve a fit)
357
358 - star: changed the fit for the effective on time such that initial
359 values are calculated automatically now instead of using build
360 in values. This makes the fit more indepedant of the underlaying
361 rates. With a test of ~350 sequences in the test database it could
362 be shown that the new fit gives the same result +/-1sek.
363 The highest deviation was +5s the lowest -10s. You can now control
364 the bahaviour with two resource values:
365 MHEffectiveOnTime.FistBin: 3
366 MHEffectiveOnTime.NumEvents: 12000
367 Use FirstBin=1 and NumEvents=120 to fit the effective on time
368 from the resulting gamma candidates
369
370 - star: The Center histogram in MHHillas is now by default displayed
371 with the colz draw-option
372
373 - ganymed: now produces valid error codes if failed
374
375 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
376 with the option "hadronness" instead of "area" or "both" if
377 you want to use both cuts. The hadronness cut includes a fixed
378 cut in hadronness (index 8) and a fixed cut in size (index 9).
379
380 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
381 the M3Long of the anti source to be not properly evaluated
382 (actually is was evaluated as a unique random number) in case
383 of optimization with anti-theta cut switched on. This might have
384 lead to improper, but not necessarily wrong, optimization results.
385
386 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
387 how to use random forest
388
389 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
390 ganymed_onoff.rc. Seems to be unintentional that they were different.
391
392 - sponde: Since the introduction of the possibility to define a
393 normalization energy instead of using the integral the default
394 was not using the integral anymore but a normalization energy of
395 1GeV. It is now the integral again.
396
397 - sponde: Fixed a problem in the weighting which did not allow
398 a MC slope of -1.
399
400
401
402 *** Version 0.9.6 (2006/05/24)
403
404 - general: changed the binning of the azimuthal profile of the camera
405 such that it is aligned with the 60deg boundaries.
406
407 - merpp: better handling of problems with the TH, TD part of the
408 CC-REPORT for files older than 200507190 and 200412210
409 respectively
410
411 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
412
413 - merpp: implementd latest changes in starguider reports (sinc 9th May)
414
415 - callisto: if an arrival time is extracted outside the fadc range is
416 was set to the boundary before. Now a random number is assigned
417 instead to avoid unfortunate coincidences of arrival times just
418 by this arbitrary value.
419
420 - callisto: added a new option to callisto.rc which allows
421 to set the maximum arrival time difference allowed for the
422 badpixel algorithm to determin whether a pixels belongs to a shower:
423 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
424
425 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
426 to 0.9 as suggested by Stefan due to a recent study on the fraction
427 of pixels surviving the image cleaning
428
429 - callisto: switched off error in case of "pulse is too much to the left"
430
431 - callisto: The extraction window is not adapted anymore. This means that
432 the pulse is extracted from the full range. The draw-back is that the
433 background (pedestal) will become slightly higher. Switching on/off
434 the PulsePosCheck in the callisto.rc only effects filling the
435 histograms.
436 WARNING: If the pulse is too much to the left data is calibrated!
437 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
438 in the database to make sure that your data is valid!
439
440 - star: Show also the number of stars correlated correctly by the
441 starguider
442
443 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
444 than one off-source region in wobble-mode. To use it add the following to
445 your ganymed_wobble.rc:
446 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
447 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
448 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
449 + Cut1.ThetaCut: None
450 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
451
452 - ganymed: in the case the latest report is older than a default (currently
453 one minute) and the current report will be skip the starguider
454 correction and calibration will be reset. The maximum age can be
455 setup from ganymed.rc by (minutes):
456 MPointingDevCalc.MaxAge: 1.5
457
458 - ganymed: A first implementation showing all size-bins for the theta-sq
459 resp. alpha-plots in a single tab automatically
460
461
462
463 *** Version 0.9.5.1 (2006/05/05)
464
465 - general: Added a new option "zdiff" to the Makefile which runs
466 "cvs diff" as "make diff" would do, but with compression
467
468 - general: accelerated MTFillMatrix (used for eample in all training
469 and optimization macros) by skipping some obsolete calles in the
470 eventloop the first and second loop could be accelerated by ~20%
471
472 - general: Added a missing feature in the MFilterList class which
473 prevented MFEnergySlope from working correctly in trainenergy.C
474
475 - general: Accelerated the random forest training and usage a bit
476
477 - merpp: Adapted to new raw data file format version 6
478
479 - merpp: fixed a problem with reading the starguider reports
480 after 6.3.2006
481
482 - callisto: At some times six pixels had to be exchanged manually in the
483 data. If the pixels to be swaped are both not found, an error was raised
484 and calibration was stopped. Now it is assumed they are intentially not
485 mapped and the Error has been changed to a Warning.
486
487 - star: Added new image cleaning based on the arrival time of the shower.
488 The new cleaning can be accessed using the parameter "Time" instead of
489 the the old one (like "Absolute) in the star.rc-file.
490 Recommended parameters:
491 + MImgCleanStd.CleanLevel1: 8.2
492 + MImgCleanStd.CleanLevel2: 5
493 + MImgCleanStd.CleanRings: 2
494 + MImgCleanStd.KeepSinglePixels: No
495
496 - star: Simplified the calculation of the effective on time. By letting
497 the fit start in the third bin the result should become more stable.
498 The fit quality is now ignored for the theta-plot which is not used
499 in the analysis later. Still better pre-cut which, for example,
500 remove events triggered by car-light (rate changing on a short
501 time-scale) are missing.
502
503 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
504 for optimization (kWeakSource) which is suggested by the Berlin
505 people for weak sources.
506
507 - macros: plotdb.C:
508 + if no dataset and no time-interval is given only sequences with
509 an effective on-time above five minutes are plotted anymore
510 + added a new tab "RelTime" displaying the relative on-time
511 (effective on-time divided by the observation time)
512
513 - macros: optim*.C: by skipping some obsolete calles in the eventloop
514 the optimization became a lot faster
515
516 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
517 To display them just delete the pads displayed on top.
518
519 - ganymed: fixed a bug which could cause strange behaviour in wobble
520 mode if no starguider information was available due to an incorrect
521 initialization of the starguider calibration
522
523 - ganymed: The scale region in the False Source Plot (MHDisp) can now
524 be changed from within the plot. It can also be setup from the
525 resource file using:
526 + MHDisp.fScaleMin: 0.325
527 + MHDisp.fScaleMax: 0.475
528
529 - ganymed, showplot: Fixed a problem with the fit to the off-data
530 (HistOff) which could cause a time lag or an inifinite loop.
531 The bug did not effect the results at all.
532
533 - sponde: Added a new tab showing the effective collection area after
534 trigger (including the software trigger)
535
536 - sponde: MMcSpectrumWeight has a new option which allows to define
537 the scaling factor not by the integral of the events but at
538 a defined energy:
539 e.g. MMcSpectrumWeight.NormEnergy: 200
540
541 - MTFillMatrix, sponde: by skipping some obsolete calles in the
542 eventloops the loop could be accelerated by ~20%
543
544
545
546 *** Version 0.9.5 (2006/03/13)
547
548 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
549 and added the standard Disp-parametrization
550
551 - macros: added a new macro datacenter/macros/plotstat.C allowing
552 to plot statistics about the data processing
553
554 - macros: added a new macro to plot the muon correction coefficients
555 versus period (macros/plot/mucal.C)
556
557 - showplot: path inflation for ganymed files was broken
558
559 - callisto: Fixed an important bug. When the number of saturating pixels
560 were calculated the bad pixel information already available from the
561 calibration was ignored. This yields wrong values in case pixels
562 are broken and saturate all the time or randomly.
563
564 - callisto: Updated Muon calibration constants. Spline data now also uses
565 different values for different periods
566
567 - star: The time-evolution shown in the effective on-time plot now displays
568 the axis range (if there are no holes it should be similar to the
569 effective on-time)
570
571 - star: Added two new image parameters:
572 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
573 the three pixels next to the center of gravity and the size
574 + MNewImagePar.fConcCore: The ratio of the signals of all
575 pixels inside or touching the ellipse and the size
576
577 - ganymed: now stops in requested source isn't found in catalog file
578
579 - ganymed: Many improvements to the phi-plot in wobble mode:
580 + with a template the ideal background is displayed
581 + a possible camera inhomogeneity is taken into account
582 + the anti theta cut is better supported
583 + the phi cut is automatically calculated from the theta cut
584 See the examples in ganymed_wobble.rc for more details.
585
586 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
587 times the bin-width instead of the absolute energy
588
589 - ganymed: New cuts for on/off and wobble mode
590
591 - ganymed: The smearing of the False Source plot has been increased
592 to 0.06
593
594 - ganymed: The starguider calibration can now be changed from the
595 resource file.
596 See the examples in ganymed*.rc for more details.
597
598 - ganymed: added a new option for on-/off-observations
599 MJCut.RandomSourcePosition
600 If switched on the distribution of observation time of the source
601 position in the camera is calculated from the on-data and randomly
602 applied with this distrbution to the off-data.
603
604 - ganymed: by skipping some obsolete calles in the eventloop the
605 first and second loop could be accelerated by ~20%
606
607 - ganymed: The default in ganymed_onoff.rc is now to determin the source
608 position in the off-data randomly according to its distribution in the
609 on-data.
610
611
612
613 *** Version 0.9.4.3 (2006/02/13)
614
615 - general: Fixed a bug in most of the programs which prevented the
616 compile date in the startup message to be displayed
617
618 - general: Simplified program calls. The following abbreviations
619 are now possible:
620 showlog callisto 55599
621 showplot signal 55599
622 star 55599
623 callisto 55999
624 ganymed 2
625 In this cases the corrsponding root-, log-, sequence- or dataset-
626 filename is automatically compiled using the default datacenter
627 paths ("/magic/*")
628
629 - general: Fixed a long outstanding bug which made axis tick marks
630 disappear if MDataFormula was used (eg. abs(x))
631
632 - general: Updated MMath with new functions to calculate the results of
633 a exponential, logarithmic and powerlaw fits analytically.
634
635 - general: Updated some macros with comments:
636 + macros/optim/optimdisp.C
637 + macros/optim/optimenergy.C
638 + macros/optim/optimwobble.C:
639
640 - general: MTFillMatrix (the class to fill one or two MHMatrix from
641 files) now allows adding a pre-cut like in the optimization. E.g. this
642 is useful to perform g/h-separation cuts before training the random
643 forest.
644
645 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
646 correctly assigned in the raw data assignement table. A fix to correct
647 the assignment tabel have been implemented.
648
649 - general: MAstroCatalog now allows rotating of the sky-grid and stars
650 by 90, 180 and 270 deg.
651
652 - general: the macro plotdb.C now allows to highlight sequences belonging
653 to a datset. For more details see the descritions in the macro.
654
655 - StatusDisplay: Fixed the algorithm to calculate the size ratio
656 of the display, it gave wrong results espacially for big sizes.
657 Now the embedded canvas should always have a ratio width/height=3/2.
658 The "Size" options have been updated with values fitting the 3/2
659 size ratio.
660
661 - RanForest:
662 + Updated the random forest classes to support also the
663 regression method implemented by Thomas H.
664 + added new tutorial macro how to train the random forest
665 for energy estimation (macros/optim/rfenergyest.C)
666 + new classes to train the random forest (still in development)
667 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
668 + new tutorial macros for random forest training in macros/train
669 trainenergy.C, traindisp.C, trainseparation.C
670
671 - mars: now allows to setup a cut in the resource file mars.rc to choose
672 the events to be displayed, eg:
673 Cut.Condition: {0} && {1}
674 Cut.0: MHillas.fSize>100
675 Cut.1: MHillas.fSize<900
676
677 - merpp: Made aware of the new .rep format 200510250. This includes
678 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
679 the discriminator thresholds (MCameraTD) and the disciminator
680 delays (MCameraTD). All of them come with the CC report and are therefor
681 written to the CC tree.
682
683 - callisto: fixed a bug in the calculation of the arrival times in
684 the Digital Filter. They were all shifted by the same amount
685 fHiGainFirst. This caused an offset in the order of the position of
686 the left border of the extraction window in the times calculated
687 from high-gain and from low-gain. The bug effected only the absolute
688 arrival times. The bug was there since 30.1.2005.
689
690 - callisto: Changed the ExtractionWindow for the pulse position check
691 such that the camera inhomogeneity becomes as less as possible and
692 comparable to the pulso position check switched off. More details
693 on the study will be given at our result web-page.
694
695 - ganymed: ganymed.rc, ganymed_onoff.rc:
696 changed to new cuts trained with 1ES1218 and Crab-data
697 for maximum sigma*log10(excess)
698
699 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
700 a new option was implemented to estimate Disp (CalcDisp)
701
702 - ganymed: Implemented two new options which allow
703 to overwrite the default path to search for the sequence files
704 --ins=/magic/sequences
705 and where to search for the image data
706 --ind=/magic/data/star
707
708 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
709 dx/dy from the resource file by
710 MSrcPosCorrect.Dx
711 MSrcPosCorrect.Dy
712
713 - ganymed: fixed reading the source catalog. Only as many chars
714 as the requested source name had were compared (If a source
715 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
716 were requested it could happen that the coordinates of
717 "1ES1218" were read) The source coordinates are now printed
718 in addition to its name to the logging output.
719
720 - ganymed: changed the background fit in the case of a ThetaSq function
721 from a polynomial to a exponential, this should give a big improvement
722 for on-only analysis'
723
724 - ganymed/sponde: Calculation of the error of single size-/energy-
725 bins now uses Li/Ma (5) instead of LiMa (17)
726
727 - sponde: Added a plot E^2*dN/dE
728
729 - sponde: The energy estimator plot should now show values like
730 they are commonly used.
731
732 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
733 (a powerlaw with cutoff didn't work before)
734
735
736
737 *** Version 0.9.4.2 (2005/10/01)
738
739 - general: added new tutorial macro macros/tutorials/threshold.C:
740 how to calculate the threshold
741
742 - general: added a new game. Start it from the interpreter with
743 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
744 and MagicReversi)
745
746 - general: neighbor pixels in MGeoms are now sorted clockwise
747
748 - merpp: made aware of new format 20050829-0
749
750 - callisto: New scale factors from muon analysis, stored in new
751 resource file resources/calibration.rc
752
753 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
754 the eventloop if something went wrong. This is necessary for the
755 automatic processing
756
757 - callisto: Implemented a new treatment for the time information
758 developed by S.Ruegamer, this should give much better response than
759 the old very primitive algorithm. This is especially important
760 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
761 treatment was buggy! As neighbor pixels to interpolate the
762 arrival times always the pixels 0 to 5 were taken)
763
764 - callisto: In addition to the new treatment of arrival times the
765 decision of the treatment whether a pixel contains shower
766 information or not is used to improve the signal interpolation
767 further. Previously interpolated pixels showed a non-zero signal
768 do the peak searching signal extractors. Having a signal pixel
769 beside raised the signal above the cleaning level. Thus the
770 pixel survived cleaning to often but with a too low mean signal.
771 By replacing empty pixels with a gaus (mean and rms from the
772 corresponding Area entries in MPedPhotCam) this effect can
773 be supressed.
774
775 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
776 got lost when the events were stored by the calibration... fixed.
777 (This was no problem for normal image cleaning because the pixel
778 content was artificially set to 0 not surviving standard cleaning
779 algorithm)
780
781 - callisto: Fixed a bug which caused the random and peak-search pedestal
782 extracted with an extractor to be exchanged for the first (roughly)
783 500 events (*Extractor and *ExtractorRndm).
784 (They were simply exchanged in callisto.cc) This bug might have been
785 introduced in Mars 0.9.4 when the order of calculation of the two
786 types of pedestal in callisto got exchanged. The bug only effects
787 the first seconds of data of each sequence.
788
789 - star: Taking the arrival time of Muons into account the calculation
790 of the parameters could be made independant of the noise
791 (pedestal rms). The dependance was due to the bias of the peak search
792 extractor. Now only a ZA dependamcy is left which is not yet fully
793 understood.
794
795 - ganymed: The sequences were still not sorted correctly in any case,
796 because they were sorted by the full qualified path name. Now they
797 are sorted by their sequence number.
798
799 - ganymed: new values for the spark-event-cut
800
801 - sponde: required missing MEnergyEst from ganymed.root... fixed.
802
803
804
805 *** Version 0.9.4.1 (2005/08/18)
806
807 - callisto: fixed some problems with the calibration in case of
808 inteleaved events. Therefor the final and some intermediate
809 fits are skipped which would take place on partly filled #
810 histograms and gave wrong results or failed completely.
811
812 - callisto: If the intermediate finalization of the histograms
813 calculating the mean charge of the calibration signal fails
814 it is counted now and printed in PostProcess of MCalibCalcFromPast.
815
816 - ganymed: Fixed some bugs which caused problems in On-only mode.
817 Still the false source plot doesn't give reasonable results.
818
819
820
821 *** Version 0.9.4 (2005/08/05)
822
823 - general: Fixed the ZA binning. It did not correctly fit the
824 MC binning
825
826 - general: Added a class to correct for the missfocussing in
827 April (MSrcPosCorrect)
828
829 - general: Random Forest energy estimator should now work properly
830
831 - general: MHCamera now displays the profiles in deg instead of mm
832
833 - general: MH::SetPalette offers a lot of new palettes
834
835 - general: MHillas - the case of CorrXY==0 is now handled properly
836
837 - general: implemented the possibility to change the line and
838 marker style of a sky-grid drawn by MAstroCatalog
839
840 - general: Runs in sequences and datasets are now automatically
841 ordered (it is assumed that the order of their filenames correctly
842 represents the order of observations) to ensure correct reading
843 of the subsystem data
844
845 - general: Runs cannot be added to a sequence twice anymore. Also
846 Sequences cannot be added twice anymore to a dataset.
847
848 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
849 It gave wrong results by 1./2pi
850
851 - showplot: got a new option to start a root interpreter, too
852
853 - mars: now displays a rough estimate of Disp and the third moment
854
855 - mars: now displays the event time MTime if available
856
857 - mars: show muon parameters graphically
858
859 - mars: now the file to open can be given as commandline
860 argument
861
862 - merpp: Added support for new arehucas version >= 200507190
863 implementing values for three temperature sensors in the
864 counting house (MCameraAUX) and the name of the HV settings file
865 (MCameraHV).
866
867 - merrp: Also fixed some problems with wrong versions numbers stated
868 by arehucas and implemented some fixed for old versions (<200407070)
869
870 - callisto: MCalibrationHiLoCam can now be printed from its context
871 menu, eg in the TBrowser
872
873 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
874 - 1.39 (MExtractTimeAndChargeSpline)
875 - 1.40 (MExtractTimeAndChargeDigitalFilter)
876 This is important mainly for timing studies.
877
878 - callisto: Changed limits in MHCalibrationChargeCalc from
879 - -100.125 to -98 (fgChargeHiGainFirst)
880 - 1899.875 to 1902. (fgChargeHiGainLast)
881 - -100.25 to -99 (fgChargeLoGainFirst)
882 - 899.75 to 901. (fgChargeLoGainLast)
883 Introduced new limits:
884 - fgNumLoGainBlackoutLimit: 0.05
885 - fgLoGainBlackoutLimit: 3.5
886 - fgLoGainPickupLimit: 3.5
887
888 - callisto: The handling of automatic weights for the digital filter
889 has been improved. There are now new calibration weights special
890 for Monte Carlo calibrations.
891
892 - callisto: Updated Muon scale with latest results (1% difference
893 for most data, 5% for Mar/Apr'05)
894
895 - callisto: use a new criterium to exclude bad pixels: If the high-gain
896 was saturated and the blackout-events in the low-gain exceed the
897 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
898 This excludes those pixels which have a saturating high-gain
899 channel, but the low-gain switch does not switch often enough
900 to make the distribution reliable.
901
902 - callisto: fix a bug counting the number of saturated events. Up to now,
903 the number of saturated slices was counted (which is one for a not too
904 high number), but for some (pathological) pixels, many more slices
905 saturated and produced wrong limits.
906
907 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
908 + MCalibrationRelTimeCam.CheckFitResults: Yes
909 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
910 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
911 + MCalibrationRelTimeCam.CheckOscillations: Yes
912
913 - callisto: introduce max. number of events for intercalibration,
914 the rest gets skipped. Default: 4096
915 The calibration causes too many un-reliable pixels if more
916 than about 5000 events are treated (@500 Hz) because of the
917 mode hopping of the VCSels. However, in the past, some
918 calibration runs have been taken (erroneously) with more
919 than 5000 events, especially the intensity scans where
920 a good precision is needed.
921
922 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
923 photo-electrons for the spline extractor by 1-2% (correctly).
924
925 - callisto: The intercalibration is now done using a full f-factor
926 method instead of a simple update. This makes things slower but
927 more reliable in terms of gain-fluctuations and sudden VCSEL gain
928 changes.
929
930 - callisto: MPedestalY3 now uses the same extraction range as the data
931 as calculated by MPedestalY2
932
933 - callisto: A check of the fraction of allowed unsuitable (10%) and
934 unreliable (30%) pixels has been addded when the conversion is
935 calculated from interleaved events
936
937 - star: fixed a bug which caused MEffectiveOnTime containers not to
938 be written. In the worst case they were skipped almost all, in the
939 best case they were all ok. It depends on how often the new value
940 was assigned just with an event which was skipped later by another
941 task
942
943 - star: new histograms MHPointing and MHRate
944
945 - star: New tab (Currents) displaying the time evolution of the mean
946 DC currents
947
948 - star: New tab (MeanRms) displaying the time volution of the mean
949 Pedestal Rms
950
951 - star: Output now contains MReportStarguider
952
953 - star: Improved muon analysis. Due to the absense of a constant
954 for the gaus fit for arc width and the fact that the arcwidth
955 plot was a histogram instead of a profile the resulting psf
956 became pedestal rms dependant
957
958 - ganymed: added new plot (MHPhi) for wobble mode as described in
959 http://www.astro.uni-wuerzburg.de/results/ringmethod/
960
961 - ganymed: corrects now (correctly?) for the misspointing in
962 May/April 05
963
964 - ganymed: Two new default templates for ganymed.rc are avilable:
965 ganymed_onoff.rc and ganymed_wobble.rc
966
967 - ganymed: The first version of MFMagicCuts has been released
968
969 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
970
971 - ganymed, sponde: There are two new options to determin the number
972 of bins for the signal region (NumBinsSignal) and the number of
973 total bins (NumBinsTotal) in the MHThetaSq histogram
974
975 - ganymed: optimized palettes for MHDisp
976
977 - ganymed: Fixed an important bug when using ThetaSq as fit function:
978 The result for the sigma of the gauss(sqrt(x)) fit was a factor
979 sqrt(2) to large
980
981 - ganymed: The false source plot (MHDisp) is now based on Disp
982 and a background model determined in the first loop is
983 subtracted
984
985 - ganymed: MFMagicCuts are now available in the cvs. The correct
986 solution for the disp ambiguity problem is now calculated using
987 the third moment. The third moment cut therefor is skipped.
988
989 - ganymed: Output now contains "Disp [MParameterD]" which sign is
990 already determined by the third moment along the major axis and
991 so its actual sign is aligned along the major axis of the shower.
992
993 - ganymed: If starguider data is available it is taken into account
994 when calculating the source position. This is especially important
995 for wobble data at high zenith angles and culmination data.
996
997 - ganymed: If available the starguider data is taken into account as
998 good as it is possible without a starguider calibration. To switch
999 it off add
1000 MPointingDevCalc.MaxAbsDev: -1
1001 to your ganymed.rc
1002
1003 - sponde: the zenith angle distribution is now weighted instead of
1004 choosen by default. This gurantees higher statistics in the highest
1005 and lowest energy bins. To switch this behaviour off use...
1006
1007 - sponde: now automatically displays the energy threshold
1008
1009
1010
1011 *** Version 0.9.3 (2005/06/03)
1012
1013 - general: MMcEvt now derived from MMcEvtBasic which should
1014 have no influence on compatibility with older camera files
1015
1016 - general: Implemented a new option to MReadReports which allows
1017 to force reading of the first event of some trees (eg. Drive-tree)
1018 before any other tree.
1019
1020 - general: Made a fix to MPointingPosCalc which assumes that the
1021 run-type is real-data if Process is called before ReInit, such
1022 that also the very first Drive-events in a run are treated
1023 correctly.
1024
1025 - shoplot now displays the filename in the title bar of the window
1026
1027 - merpp: new options: --auto-time-start --auto-time-stop which
1028 allow to cut updating with slow-control at the start- or
1029 (previousle --auto-time only allowed: and) stop-time of
1030 the run stored in the runheader.
1031
1032 - callisto: changed default of fgFallTimeHiGain in
1033 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1034 already set as default in callisto_Dec04Jan05.rc
1035
1036 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1037 now changes the filename for new weights automatically for
1038 cosmics, MC and for different calibration colors.
1039
1040 - callisto: a problem with the order of some code cause the
1041 name of the weights file in MPedestalY2 to be ignored.
1042 Wrongly the calibration_UV weights were used instead
1043 of the cosmics weights set in callisto.rc.
1044
1045 - callisto: should allow ct1 pulser data when the color is
1046 explicitly set also for pretty new runs
1047
1048 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1049 to introduce an additional scale factor (should be around 1)
1050 to adapt for slight deviations in different extractors from
1051 the MC calibration. For MC calibrations the scale factor
1052 is fixed to 1
1053
1054 - callisto: MFCosmics should handle very high signals a bit
1055 more accurate now
1056
1057 - callisto: when calculating the mean pedestal rms for different
1058 pixel sizes or sectors also kUnsuitableEvt is now taken into
1059 account - not only kUnsuitableRun
1060
1061 - callisto: '-raw' option is now the default
1062
1063 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1064 This has the advantage that mean values in the calibration (eg
1065 arrival times) are calculated more accuratly.
1066
1067 - callisto: In the resource file callisto_Dec04Jan05.rc
1068 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1069
1070 - callisto: new Hi-/Lo-Gain intercalibration constants
1071 hilocalib_sp1.root and hilocalib_sp1_mc.root
1072
1073 - callisto: changed default for MJPedestalY2.MaxEvents
1074 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1075
1076 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1077 has changed from 9.0 to 6.0. This is necessary to exclude two very
1078 ringing pixels in September which - when kept - destroy the image
1079 cleaning around them (Markus G.)
1080
1081 - callisto: (!) The Muon analysis of all data taken so far has
1082 suggested that different extractors give slightly different
1083 absolute results after calibration, due to there different
1084 handling of the calibration- and cosmics pulse shape. Although
1085 the over all calibration seems to be a bit to pesimistic (or
1086 the MC seems to be a little bit - 3-5% - too much attenuated).
1087 There for correction factors have been introduced which correct
1088 the calibration constants by
1089 0.956937799 for Digital Filter (callisto.rc)
1090 and
1091 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1092 calibration. The main advantage is, that both data types can
1093 be easily analysed together and compared to the same MC sample.
1094 The factors are choosen such, that the reference is now a
1095 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1096
1097 - star: fixed a bug which caused the first bin of the histograms
1098 vs time to disapear in PostProcess. This gave wrong results
1099 on the screen. The output and all following programs not
1100 directly accessing the histograms haven't been affected
1101
1102 - star, ganymed: Made sure that always the first Drive-tree event
1103 is read and Processed before the first data event was read.
1104
1105 - ganymed: implemented the possibility to replace the standard
1106 false source plot with a different one. For example: If
1107 you want to use a Disp based FS plot use the resource:
1108 NameHistFS: MHDisp
1109 For details about the requirements of these plots look
1110 at the corresponding classes
1111
1112 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1113 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1114 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1115 case MAlphaFitter is setup correctly. For On-Only optimization
1116 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1117 RunOn() instead of Run(). For energy estimation MJOptimize
1118 has been replaced by MJOptimizeEnergy
1119
1120 - sponde: The input MC spectrum can now be weighted to fake a
1121 different spectrum. This is done via MMcSpectrumWeight. For
1122 more details see the class description and sponde.rc
1123
1124 - sponde: The paremeter comparsion plots are not scaled by
1125 their entries anymore. Instead the MC plot is scaled by using
1126 the result spectrum of the analysis. If the input MC spectrum
1127 and the result spectrum has different slopes the absolut
1128 normalization is normally wrong.
1129
1130
1131
1132 *** Version 0.9.2 (2005/05/20)
1133
1134 - general: Changed the default paths for calibrated data and image
1135 files. (The implemented access to these files doesn't yet exist)
1136
1137 - general: support for MRunIter has been removed from the job classes
1138 (use the setter functions of MSeqeunce instead)
1139
1140 - general: ProcessFile has been renamed to Process in all job classes,
1141 because ProcessFile is missleading
1142
1143 - general: The storage of the palette in MHCamera is now possible
1144
1145 - general: new bits describing unsuitable and unreliable pixels have
1146 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1147 kDeadPedestalRms, kFluctuatingArrivalTimes
1148
1149 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1150 versions newer than V200404070
1151
1152 - general: support for cc file versions newer than V200504130. Added
1153 support for active loads (MCameraActiveLoad) and central pixel
1154 (MCameraCentralPixel)
1155
1156 - general: added new histograms for image parameters versus size
1157 (MHVsSize)
1158
1159 - general: The eventloop now automatically calls PrintStatistics
1160
1161 - Status Display: Improved support for printing:
1162 + A default can now be set in .rootrc (for more details see
1163 MStatusDisplay::PrintPS)
1164 + A print dialog is opened so that printer and command line
1165 can be canged
1166
1167 - showlog: improved such that it handles different verbosity levels
1168 more accurate now. This mean you can suppress output when
1169 using showlog.
1170
1171 - showplot: improved
1172 + The new graphics formats have been implemented
1173 (pdf, svg, png, jpg and xpm)
1174 + Implemented an interface for printing. Because you can change
1175 the printing command from the command line you can use all
1176 the nice postscript tool. To print a booklet for example call:
1177 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1178 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1179 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1180
1181 - callisto: fixed a bug in the recognition of the calibration bit
1182 pattern. Concerns only intensity calibration. (The strength of the
1183 intensity has been updated in some cases)
1184
1185 - callisto: add a filter against PIN Diode events when running over
1186 calibration runs since some of the recent calibration runs have
1187 been taken with Pin Diode.
1188
1189 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1190 39943, 44833 in the calibration (MCalibColorSet)
1191
1192 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1193 been set to 1e-18 in callisto_Dec04_Jan05.rc
1194
1195 - callisto: in callisto_Dec04Jan05.rc: set value for
1196 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1197 statistics for the calculation of the mean pulse time
1198 of the cosmisc
1199
1200 - callisto: the charge limit in the calibration has been raised
1201 from 2.5 to 4.5
1202
1203 - callisto: new setup read from callisto.rc
1204 + MCalibCalcFromPast.fNumEventsDump
1205 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1206 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1207
1208 - callisto: MExtractTimeAndChargeSpline extractor:
1209 + The integration ranges were shifted by 0.2 FADC slices to the right.
1210 + unreliable handling of floating point values caused different
1211 results on different platform or with different compiler options:
1212 The new algorithm is numerically exact and more accurate because
1213 it doesn't calculate the integration position by multiple times
1214 adding the step-size (which results in numerical uncertanties
1215 exspecially if multiplied with large numbers)
1216 + A lot of fixes have been introduced which effects integrating the
1217 spline at the edges of the valid range. In this case any memory
1218 was randomly accessed. This behaviour can be tested replacing
1219 all MArrayF by TArrayF which perform a range check (but of course
1220 they are a lot slower)
1221 ! No result obtained with the Spline before can be trusted! Due to
1222 random memory access it might by completely random!
1223
1224 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1225 + extraction range in the high gain to 4.
1226 + weights file to cosmics_weights46.dat
1227
1228 - callisto:
1229 + introduce the check for fluctuating arrival times.
1230 + set charge limit to from 2.5 to 4.5
1231 + introduce asymmetric exclusion due to "deviating number of phes":
1232 Default: -9.0 +4.5
1233 + make deviating number of phes unsuitable (see David's findings).
1234
1235 - callisto: fixed the display of unsuitable pixels. The old change
1236 to a real profile in MHCamera broke it.
1237
1238 - callisto: The cosmics filter is used in MJCalibration now
1239 independant of the pulser color (formaly it was used only for
1240 CT1-pulser data). The threshold of number of max empty pixels
1241 has been raised from 2% to 5% in MJCalibration. The maximum
1242 fraction of rejected event is 50% otherwise the calibration has
1243 failed. The filter now ignores unsuitable pixels.
1244 Setup the filter from callisto.rc using "ContCosmics"
1245 (see MFCosmics::ReadEnv)
1246
1247 - callisto: changed default for fgOffsetFromLogain back
1248 from -2.8 to -1.8 in digital filter.
1249
1250 - callisto: for the common extractors
1251 + MExtractFixedWindow
1252 * MExtractTimeAndChargeSlidingWindow
1253 * MExtractTimeAndChargeSpline
1254 * MExtractTimeAndChargeDigitalFilter
1255 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1256 and fResolutionPerPheLoGain
1257
1258 - callisto: Updated the hi-/lo-gain intercalibration constants
1259 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1260 hilocalib_df6.root
1261
1262 - callisto: The default lo-gain extraction window for the
1263 MExtractTimeAndChargeSlidingWindow extractor has been increased
1264 from 6 to 8 to take the stretch of the pusle into account
1265
1266 - callisto (!!!): fixed an important bug in the setting of the
1267 incoming pedestal pointer to the signal extractor extracting
1268 pedestals. This bug caused the pedestals not to be subtracted
1269 correctly in the calibration afterwards. The effect was about 10%
1270 too high conversion factors for the digital filter and the spline
1271 and more than 40% for the sliding window.
1272 The bug existed since end of February! (Markus G.)
1273
1274 - star: added muon support to star. A new tab "MHMuonPar" is
1275 displayed. The lower right plot is an estimate of the point spread
1276 function. A reference value is displayed. To get the real PSF
1277 you must compare with MC. The setup for the muon analysis
1278 is done in star.rc. More informations can be found in
1279 MHSingleMuon and MHCalibParCalc
1280
1281 - star: The weather data is now displayed in star
1282
1283 - star: MEventRateCalc handles the calculation of the event rate more
1284 accurate now in case of the start of a new run inside a sequence
1285
1286 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1287 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1288 changed only minimally
1289
1290 - ganymed: (MJCut and MJOptimize) now displayes the number of
1291 excess events versus size. The energy estimation is done in
1292 MJSpectrum (sponde)
1293
1294 - ganymed: got support for using other variables than Alpha, eg. Theta.
1295 Therefor you need a class deriving from MHAlpha which supports
1296 this variable (one is already existing: MHTheta, which is now the
1297 default in ganymed). It is setup through ganymed.rc
1298
1299 - added a full featured spectrum program (sponde) which reads
1300 ganymed output and monte carlos and compiles a spectrum
1301
1302
1303
1304 *** Version 0.9.1 (2005/04/14)
1305
1306 - Fix bug on the arrival time reconstruction when using Digital
1307 Filter (in some marginal cases (10%) times were reconstructed shifted
1308 by 0.2 slices)
1309
1310 - all executables now return 2 where in previous versions -1 has
1311 been returned (gave problems with shell-scripts)
1312
1313 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1314 also done with a intercalibration input file
1315
1316 - a bug in the time fine adjustment of the digital filter has been fixed
1317
1318 - a lot of small fixes to calling TPad::Divide with a margin==0
1319
1320 - MStatusDisplay now shows the memory usage
1321
1322 - added a memory leak statistic after the eventloop
1323
1324 - MHadronness replaced by MParameterD
1325
1326 - MEnergyEst replaced by MParameterD
1327
1328 - wobble mode can now be switched on from the data-set
1329
1330 - switched on bad pixel detection for a pedestal level
1331 which is more than 5 times the variance
1332
1333 - Fixed default paths to be correct for the new data center
1334
1335 - Fixed handling of drive data. The pointing position in now
1336 copied to MPointingPos inside star for real and MC events
1337
1338 - made sure, that the sequences in a dataset are sorted by
1339 their number to ensure the correct synchronization
1340
1341 - added all resource files necessary to handle spline extraction
1342 of signal for the late 2004 and the early 2005 data
1343
1344 - update the reference lines for the december data
1345
1346 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1347 This is important for the Dec. and Jan. data where the calibration
1348 pulse position changes much.
1349
1350 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1351 filter. This corrects only an defective extraction of the MC at
1352 low-gain signals lower than 90 phes.
1353
1354 - fixed some slowdown in calibrating data with interleaved events from
1355 Jan and Dec. As a workaround made the pretty palette the default.
1356 The inverse Deep Blue Sea has a bug which slows down long calibration
1357 runs a lot.
1358
1359 - implemented new values from new starguider report as defined
1360 in TDAS00-07 V7.1 (eg SkyBrighness)
1361
1362 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1363 in starguider report (If you merpp the same reports with this version
1364 you'll get the correct units (arcmin) but a different result
1365 than with old versions (wrong units))
1366
1367 - Now the status display can also write PNG, JPEG and XPM (other file
1368 formats are still unsupported by root)
1369
1370 - added a lot of scripts and macros in directory datacenter used
1371 for automatic processing
1372
1373
1374
1375 *** Version 0.9 (2005/03/23)
1376
1377 - Calibration is now done autmatically into photo-electrons like
1378 decided by the Collaboration Board
1379
1380 - Reference lines in the display can be read from resource file
1381
1382 - Interlaced calibration events can be handled by callisto
1383
1384 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1385 and applied in callisto.
1386
1387 - class MJCalibTest can be called by callisto
1388
1389 - callisto can now run with three data types: rawdata, rootdata, MC
1390
1391 - added two classes mreport/MReportStarguider.cc and
1392 mreport/MReportStarguider.h for implementing starguider-data
1393
1394 - the output of merpp-update now contains starguider information:
1395 MReportStarguider and MTimeStarguider
1396
1397 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1398 values were lower than they should. This was more visible for high
1399 energy (Size) events.
1400
1401 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1402
1403 - added a new loop to callisto to support the correct extraction of
1404 the pedestal and pedestal rms through the signal extractor
1405
1406 - added class to perform fourier tranformation of a hexagonal structure
1407 (MHexagonalFT)
1408
1409 - added class to perform fourier tranformation of a hexagonal structure
1410 in a tasklist (MHexagonalFTCalc) example: hft.C
1411
1412 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1413 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1414 small pixels, example: extendcam.C
1415
1416 - added possibility to write data to memory (TTree) using MWriteRootFile
1417
1418 - added possibility to read a TTree stored only in memory by MReadTree
1419
1420 - new classes to deal with the interleaved calibration events:
1421 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1422
1423 - implemented filters to callisto to skip calibration events
1424
1425 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1426 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1427 the slices by statistics
1428 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1429 signal extractor without randomization
1430 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1431 with the signal extractor with randomization (extraction window is
1432 randomly fixed)
1433 The three kind of pedestal is not yet implemented (for speed reasons) as
1434 long as nobody really needs it:
1435 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1436 extracted with the signal extractor with randomization
1437
1438 - callisto now finds the pulse position in the data automatically
1439
1440 - implemented data reduction in calibrated data by reducing the precision
1441 of the stored floating point values (pedestal, rms and signal) to
1442 roughly 0.5%
1443
1444 - fixed showplot to make file format conversion (eg. converting a
1445 status display stored in a root file into a postscript file) in
1446 batch mode possible:
1447 showplot -b --save-as-ps[=outfile.ps] infile.root
1448
1449 - Allow class names as part of filter rules, eg
1450 (MFSupercuts) && (MHillas.fSize>100)
1451
1452 - fixed a lot of stuff to allow all programs to process MonteCarlo
1453 camera files.
1454
1455 - enhanced possibility to debug reading of resource file
1456
1457 - MDataChain should handle priorities of operator more
1458 accurate now
1459
1460 - completely revised the container in which the signal is stored
1461 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1462 * the new implementation is faster and
1463 * needs less storage space
1464
1465 - FIRST version which can process Monte Carlos through the
1466 whole chain of programs (callisto, star, etc)
1467
1468 - implemented new image parameters for the border length of
1469 the shower image (MNewImagePar2)
1470
1471 - implemented wobble-mode in ganymed
1472
1473 - new class (MJOptimize) taking care of all optimization processes
1474
1475
1476
1477 *** Version 0.8.6 (2004/10/05)
1478
1479 - New combined signal and time extractor
1480 MExtractTimeAndChargeDigitalFilter
1481
1482 - The Report for the trigger section in the CC run summary has been
1483 updated, and now the IPRs (Individual Pixel Rates) are available.
1484
1485 - new macros for database interaction: filldotrun.C, filldotrbk.C
1486
1487 - added new program which can convert colored output which was redirected
1488 into a file back into colored text (for example to display it with
1489 more): showlog
1490
1491 - added new program to display an MStatusArray of plots (stored with
1492 MStatusDisplay) from a file: showplot
1493
1494 - Added support for Sequences (MSequence). Sequences are blocks of run
1495 files containing the same calibration and belonging to the same
1496 source
1497
1498 - Added a new task (MTaskEnv) which can be used in setup files to switch
1499 between different tasks (for example to choose a signal extractor)
1500
1501 - Implemented automatic file splitting in MWriteRootFile
1502
1503 - After image cleaning an island index is assigned to all used pixels.
1504 The index corresponds to the order of the islands in size.
1505
1506 - added a cleaning which takes signal height _and_ arrival time into
1507 account: probability cleaning (for more details see MImgCleanStd)
1508
1509 - added a cleaning which takes takes the absolute number of photons
1510 times the area ratio as cleaning level
1511 (for more details see MImgCleanStd)
1512
1513 - Changed calculation of image parameters such, that it can be done
1514 for all used pixels or the pixels with a defined island index only
1515
1516 - implemented new image parameters displaying the number of islands,
1517 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1518
1519 - event display in executable changed to support also calibrated files
1520 (done with MJCalibrateSignal)
1521
1522 - added program doing the calibration and the signal extraction
1523 and signal calibration: callisto Most part of the setup is done
1524 by a resource file: callisto.rc
1525
1526 - implemented support for pixels with negative IDs (Raw file format
1527 version 4)
1528
1529 - implemented an new option in merpp (--auto-time) to get the time
1530 range for cc and/or caco data from the run header of the raw data
1531
1532 - New star-program (star and MJStar). Taking calibrated data from
1533 callisto/MJCalibrateSignal as input. The setup is done through
1534 a resource file: star.rc
1535
1536 - Added possibility to setup the eventloop in the mars-executable
1537 Camera Display by a resource file: mars.rc
1538
1539 - The the mars-executable Camera Display can now also read
1540 calibrated data files written by callisto/MJCalibrateSignal
1541
1542 - Added a new class which can calculate the source position in
1543 the camera from a pointing model known to be correct and
1544 the pointing model used for observations (MSrcPosFromModel)
1545
1546 - added a new version of the class calculating the effective on-time
1547 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1548 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1549 MHTimeDiffTheta.
1550
1551 - added the possibility to count how often a signal is above (or
1552 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1553 can replace MHTriggerLvl0)
1554
1555 - added ore convinient ways to set the axis-titles of your histograms
1556 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1557 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1558
1559
1560
1561 *** Version 0.8.5 (2004/08/06)
1562
1563 - new Signal Extractors: MExtractFixedWindowSpline
1564 and MExtractAmplitudeSpline
1565
1566 - implementes interleave in merpp to be able to merpp parts of a file
1567
1568 - implemented force-functionality to merpp
1569
1570 - star display to display star catalogs (MAstroCatalog)
1571
1572 - star display to 'mirror' stars to the camera (MAstroCamera)
1573
1574 - implemented a new cleaning option which allows cleaning scaled with
1575 the real ratio of the rms depending on the pixel size, not only the
1576 square root of the pixelsize (MImgCleanStd, MCameraData)
1577
1578 - removed obsolete MBlind* classes
1579
1580 - Signal extractor taking the AB flag into account implemented (this makes
1581 an odd number of slices for signal extraction possible
1582 (MExtractSignalABcorr)
1583
1584 - implemented a class extracting the pedestal from the raw-data (events)
1585 itself using empty lo-gain (MpedCalcFromLoGain)
1586
1587 - Added mean values to MPedPhotCam
1588
1589 - Added Makefile for Darwin (this OS is NOT officially supported!)
1590
1591
1592
1593 *** Version 0.8.4 (2004/04/19)
1594
1595 - new fast arrival time extractor using cubic splines:
1596 MExtractTimeFastSpline
1597
1598 - implementes multi-argument support in MDataChain
1599 ("pow(a, b)")
1600
1601 - implemented double reference support in MDataChain
1602 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1603
1604 - added support in MF for expressiond like
1605 "MHillas.fWidth<2*<MHillas.fLength"
1606
1607 - MDataChain is now able to support variables like [0], [1], ...
1608 which can be used in fit functions as parameters. The interface
1609 is implemented through the new virtual function
1610 MParContainer::SetVariables
1611
1612 - added new class MArrivalTimeCam/MArrivalTimePix:
1613 Storage containers to hold the ArrivalTime of the camera/pixel
1614
1615 - added new classes for the calibration of relative arrival times:
1616 MCalibrationRelTimePix and MCalibrationRelTimeCam
1617
1618 - added new classes to extract the signal of the blind pixel and the
1619 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1620
1621 - added new classes for the bad-pixels treatment (MBadPixels*)
1622 which are more powerfull than the old ones (MBlindPixel*)
1623 and will replace them.
1624
1625 - added filter against cosmics: MFCosmics
1626
1627 - added new class MArrivalTimeCalc2:
1628 Calculates the arrival time as the signal weighted mean of the time
1629 slices in the maximum window
1630
1631 - added a new macro call pointspreadfucntion.C that fits with a 2D
1632 gaussian the DC spot for an star. It gives you the RMS of
1633 the PSF and the center of the star, very useful for misspointing
1634 studies.
1635
1636 - added support for multi-telescope camera files. Added classes
1637 MStereoCalc and MStereoPar, classes to calculate and store shower
1638 parameters calculated from the data of two telescopes, for the MC
1639 studies regarding the MAGIC clone.
1640
1641 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1642 MC data calibrated in photons instead of ADC counts.
1643
1644 - added three macros to show the calibration and analysis chain of
1645 MC data. The macro starmc.C does both calibration and analysis, producing
1646 an output containing Hillas parameters for each event. The macro
1647 mccalibrate.C does just the calibration and writes out a file containing
1648 pixel information in photons instead of FADC data. The macro starmc2.C
1649 reads in such a file and produces an output with Hillas parameters.
1650
1651 - added MPedPhotCalc to compute pedestals in units of photons, see
1652 macro pedphotcalc.C
1653
1654 - added all class to perform the calibration, see macro calibration.C
1655
1656 - added class MFFT to perform Fast Fourier Transforms
1657
1658 - added class MSimulatedAnnealing to perform simulated annealing
1659 minimizations
1660
1661 - added new macro bootcampstandardanalysis.C which holds the skeleton
1662 of the analysis chain discussed in the december bootcamp.
1663
1664 - added support for DAQ raw data file format V2
1665
1666 - implemented an arbitrary time stamp for the events from raw-data
1667 files with file version<3. It is calculated from the run number,
1668 the date of start and the FADC clock tick from the first module
1669
1670 - implemented the correct decoding of the event time-stamp
1671 coming from the DAQ for raw-data files with file-version>2
1672
1673 - added a new classes storing the pedestals in units of photons:
1674 MPedPhotPix, MPedPhotCam
1675
1676 - added support for DC current files from the camera control
1677
1678 - added support for start- and stop-time when merpping report files
1679
1680 - added MReportCC storing the weather data from the CC-REPORT
1681
1682 - added class to fill trainings and test matrices (MTFillMatrix)
1683
1684 - added a filter performing a software trigger (MFSoftwareTrigger)
1685
1686 - Added classes to perform parts of the standard analysis (Jobs):
1687 + MJPedestals
1688 + MJCalibration
1689 + MJExtractSignal
1690 Note: All of them are preliminary!
1691
1692 - Added Iterator to iterate over files giving only the run-number
1693
1694 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1695 the evolution of a sector vs time
1696
1697
1698
1699 *** Version 0.8.3 (2003/12/05)
1700
1701 - adapted Random Forest classes to allow the use with MC
1702 multi-telescope files which can be produced with the coming
1703 camera version 0.7.
1704
1705 - added classes to read and interprete central control report files
1706 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1707
1708 - enhanced merpp (the executable) to support .raw and .rep files.
1709
1710 - added classes for light calibration (MCalibration* and
1711 MHCalibration*) by Markus Gaug. Further work has to be and will
1712 be done soon.
1713
1714 - Added a preliminary 'synchronizer' (MReadReports) which will
1715 replace MReadMarsFile as soon as it is finished.
1716
1717 - Added a tutorial macro demonstrating how report files are merpped
1718 and how they can be read from the root file in the correct order
1719 of time (readrep.C)
1720
1721 - Added a generalized histogram (similar to MH3) called MVsTime
1722 which allows to plot variables (or rules - MDataChain - of
1723 variables) vs time. For an example have a look at tempvstime.C.
1724
1725 - Changed the name of the event trees:
1726 + Events --> Events
1727 + PedEvents --> Pedestals
1728 + CalEvents --> Calibration
1729
1730 - changed name of MTime in the event trees from MRawEvtTime to MTime
1731
1732 - added displaying the sector indices to the mars event display
1733
1734 - Magic Online Analysis (MOnA) implemented in a first version
1735 (see mona.cc, MOnlineDump and MOnlineDisplay)
1736
1737 - added classes to calculate event rate
1738 (preliminary: MEventRateCalc, MEventRate)
1739
1740 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1741
1742 - added classes dealing with the telescope pointing position (MPointing*)
1743
1744 - implemented the 'final' Mars time stamp based on some experiences with
1745 the new 'Synchonizer'
1746
1747
1748
1749 *** Version 0.8.2 (2003/11/10)
1750
1751 - accelerated standard analysis by a factor of 6-8 ...
1752 + doing precalculations in MGeomCam for the pixel area ratio
1753 + creating a look up table for the single pixels in MCerPhotEvt
1754
1755 - added task to calculates weights in case you want to 'change'
1756 the energy spectrum of a monte carlo file
1757 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1758
1759 - added a new executable star which implements the
1760 star.C macro as precompiled executable. Currently a flexible
1761 setup is not possible, but a 'input card' setup will follow.
1762
1763 - Starting to implement Multi-Telescope-Support based on the
1764 upcomming camera version 0.7. The base for a general support
1765 is implemented and the star-functionality is proven to work.
1766
1767 - Replaced Event-Display in and Camera-Display in the Mars GUI
1768 executable by a more convinient display base on MStatusDisplay.
1769
1770 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1771
1772
1773
1774 *** Version 0.8.1 (2003/10/20)
1775
1776 - added signal subtraction for pure on data by means of fitting
1777 the background in the off region or by performing a combined
1778 signal/background fit. Provides necessary histograms for
1779 obtaining energy spectra and a light curve.
1780
1781 - added classes to perform and study the selection of the
1782 2nd Level Trigger on MC data (example in triglvl2.C macro)
1783
1784 - added pedestal calculation
1785
1786 - implemented "democratic cleaning" (tail cut value proportional
1787 to pixel area) according to Wolfgang's suggestion.
1788
1789 - added Sigmabar treatment (calculation and basic histogramming)
1790
1791 - added basic routines to apply padding
1792
1793 - added first implementation of MARS-based source visibility plotter
1794 (needs to be linked against slalib, preliminary version)
1795
1796 - enhanced functionality of data chains: random numbers, conversion
1797 functions and access to MHMatrix objects
1798
1799 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1800 numbers under certain circumstances (runs with 0 events included)
1801
1802 - fixed a bug in the general filter MF (didn't work on some systems
1803 at all)
1804
1805 - fixed a bug in chaining files, which caused the analysis to crash or
1806 ignore files
1807
1808 - implemented more geometry classes describing the parameters used
1809 to simulate the PMT camera
1810
1811 - added new Monte Carlo classes containing the setup of the different
1812 programs in the MC chain.
1813
1814 - added a (preliminary) general task to evaluate chi-square of a given
1815 parameter in an eventloop.
1816
1817 - first implementation of a container describing the observatory
1818 location (Long, Lat, etc)
1819
1820 - added Random Forest - method for g/h-separation
1821
1822 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1823 (this means, that it is compiling, but not yet fully tested)
1824
1825 - added a new status display which can show the present status
1826 of histograms while an eventloop is running (MStatusDisplay,
1827 an example can be found at status.C)
1828
1829 - reorganized directories:
1830 classes describing the image --> mimage
1831 classes containing Monte Carlo Histograms --> mhistmc
1832 classes for Random Forest method --> mranforest
1833
1834 - added (event-)weights to fill histograms
1835
1836 - colors in logging output to screen
1837
1838 - changes to the Image Parameter declaration:
1839 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1840 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1841 + MHillasExt now derives from MParContainer instead of MHillas
1842 --> Files written with the old definition are more or less unreadable
1843
1844 - reading of reflector files
1845
1846 - display data from reflector files in the camera
1847
1848 - implemented currents (and display them in the camera)
1849
1850 - logarithmic scale in camera
1851
1852 - added class to iterate through directory contents (MDirIter)
1853
1854
1855
1856 *** Version 0.8 (2002/11/18)
1857
1858 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1859
1860 - corrected 48(!) wrong entries in the Next Neighbor table of the
1861 Magic Camera (all in the inner part of the outer ring, mostly
1862 missing a single NN)
1863
1864 - Fixed a bug in the table describing the Next Neighbours of the
1865 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1866 have any neighbour)
1867
1868 - changed trigrate.C: now it calculates the pure NSB triggers from
1869 a camera file (generated with no showers), so there is no need
1870 to introduce them by hand in the BgR array (for more details
1871 please ask Abelardo)
1872
1873 - added MHHadronness (and MHadronness) as a general facility to evaluate
1874 the quality of a gamma-hadron seperation method
1875
1876 - changed MWriteAsciiFile to accept rules (MDataChain)
1877
1878 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1879 must be replaced by calles to MWriteAsciiFile::AddColumn and
1880 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1881 changed.
1882
1883 - Implemented generalized event-matrices (one row per event)
1884 (MHMatrix)
1885
1886 - implemented the one dimensional composite probabilities
1887 (MHCompProb, MCompProbCalc, comprob.C)
1888
1889 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1890 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1891
1892 - Added a camera display displaying the pixel numbers to the
1893 event display gui.
1894
1895 - Added Monte Carlo Informations to event display gui
1896
1897 - Changed the camera display to display the pixel numbering
1898
1899 - Added three buttons to the camera display to change the palette
1900
1901 - Added the number of used and core pixels after image cleaning
1902 to MHillas
1903
1904 - Changed the algorithm used in MHillas according to TDAS 02-03
1905
1906 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1907
1908 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1909
1910 - Added fCosDeltaAlpha to MHillasSrc
1911
1912 - The numbers of photons used to calculate fConc and fConc1 in
1913 MHillasExt are now scaled with the pixel size, so that one get
1914 a four times smaller value for the bigger pixels in the outer ring.
1915
1916 - added new task to smooth the camera contents (MCameraSmooth)
1917
1918 - added possibility to use interpolated pixel values for blind pixels
1919 instead of removing it completely from the analysis
1920
1921 - Implemented the possibility to save the whole eventloop with
1922 its setup to a file. This information can be read and from
1923 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1924 and MEvtLoop::MakeMacro. If you find something not working, please
1925 report - this stuff is still in a beta phase.
1926
1927 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1928 file having crab starfield, but also for all following files - fixed
1929
1930 - MTaskList::PrintStatistics can now be instructud to print also the
1931 title, too: use PrintStatistics(0, kTRUE)
1932
1933 - Changed the image cleaning so that pixels with to many 'used'
1934 neighbors are left used (to get rid of 'holes' in events)
1935
1936 - Introduced more output to the camera displays
1937
1938 - Added an array of histograms (eg one hist per run), MHArray
1939
1940 - Added a _preliminary_ version of the reader for CT1 PreProc files
1941 (MCT1ReadPreProc)
1942
1943 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1944 (thanks to Raquel)
1945
1946 - added the first energy estimator (MEnergyEstParam, estimate.C,
1947 estfit.C) using a parametrization
1948
1949 - Added some new Monte Carlo paremeter containers used to store
1950 setup information from the MC chain (MMcConfigRunHeader,
1951 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1952
1953
1954
1955 *** Version 0.7 (2002/04/30)
1956
1957 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1958 the pedestal mean value was saved incorrectly. For files from
1959 this versions we substract 0.5 from the pedestal mean.
1960 WARNING: This may effect your results, so don't wonder...
1961
1962 - First implementation of an algorithm using only triggered events
1963 for the collection area calculation
1964
1965 - Ascii Output can now also be used for parameter containers which
1966 doesn't overload MParCointainer::AsciiWrite
1967
1968 - The Ascii Output is now also capable of writing single data members
1969 of one container
1970
1971 - You are now able to change the order of the values written to the
1972 ascii file
1973
1974 - You can now specify a conversion factor for each data member written
1975 to an ascii file. This may be usefull to change the units of the
1976 data member (eg. degrees instead of millimeters in case of the
1977 hillas parameters)
1978
1979 - Replaced old MHillas by a new structure which allows you to extend
1980 the parameters stored in MHillas very easily:
1981 see MHillas and MHillasExt
1982
1983 - Added classes to handle source dependancy of image parameters:
1984 see MHillasSrc
1985
1986 - Added container (MBinning) to have a standard input for the binning
1987 in different histograms (eg. the Energy bins should be the same in
1988 all histograms)
1989
1990 - Changed Hillas histograms from mm to deg
1991
1992 - Added the flexible binning to the hillas histograms
1993
1994 - Added a filter for the alpha parameter (MFAlpha)
1995
1996 - It is now possible to write single data members of a class object to
1997 an output stream instead of the whole container only
1998
1999 - Added a generalized filter for a data member:
2000 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2001
2002 - Added a generalized Filter parser for more difficult filter rules
2003 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2004
2005 - Added new Monte Carlo histograms:
2006 MHMcEnergyImpact and MHMcEfficiency
2007
2008 - Added many new histograms needed for the flux calculation.
2009
2010 - Added a generalized histograms which can fill and show up to three
2011 data members in either a one-, two- or three-dimensional histogram, eg:
2012 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2013
2014 - Added:
2015 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2016 * calculation of <Theta> as a function of time (MHThetabarTime)
2017 they are needed in the flux calculation in
2018 order to select for a given bin in Theta (or time) the appropriate
2019 effective collection area, which is assumed to be given as a function
2020 of Theta and the true energy
2021
2022 - Added calculation of the migration matrix in the energy
2023 (MHMcEnergyMigration):
2024 the migration matrix describes the migration from the true (E_true)
2025 to the estimated energy (E_est); it is needed to determine the
2026 distribution of E_true from the measured distribution of E_est
2027 by unfolding
2028
2029 - changed the color palette in the camera display to DeapSea.
2030
2031
2032
2033 *** Version 0.6 (2002/01/15)
2034
2035 - Introduce the option of disable pixels (MBlindPixels and
2036 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2037 able to deal with Star Field NSB.
2038
2039 - Fixed a bug in the pedestals substraction
2040
2041 - Introduced verbosity levels
2042
2043 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2044
2045 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2046 work correctly (thanks to Abelardo)
2047
2048 - Introduced correct treatment of the diffuse Night Sky Background
2049 and NSB (MMcPedestalNSB)
2050
2051 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2052
2053 - Introduced MMcRunHeaders which contains monte carlo run informations
2054
2055 - Added a 'Print'-Task (MPrint) which calls the Print function
2056 of a parameter container for each event
2057
2058 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2059
2060 - changes to be more efficient with root 3.02/06
2061
2062 - root 3.02/06 fixes:
2063 + the memory leak when reading MRawEvtData
2064 + loosing more time than necessary to update the progress bar
2065
2066 - MWriteAsciiFile is now capable of writing more than one container
2067 in a line. For example: To be able to write Monte Carlo and
2068 Hillas values (energy and alpha) in one line.
2069
2070
2071
2072 *** Version 0.5 (2001/11/06)
2073
2074 - Added new GUI functionality (Analysis)
2075
2076 - Added a camera display to be able to display events in the camera
2077 together with the calculated hillas ellipse
2078
2079 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2080 object at any state of the analysis, so that the output are several
2081 states
2082
2083 - Fixed a bug in the collection area error calculation
2084 (Thanks to Ciro and Abelardo)
2085
2086 - Fixed a bug which causes merpp to crash in some environments
2087
2088 - Implemented auto enabling scheme for Branches to speed up reading
2089 a lot (see MReadTree and MTask)
2090
2091 - Fixed a bug in the Histogram classes which caused histograms to
2092 be written to a file by MWriteRootFile without request
2093
2094 - changed the object I/O from the old stylish root I/O to the new
2095 'auto evolution scheme' This was done only for classes which are not
2096 yet used in Monte Carlo files, so that these files are still readable.
2097
2098 - Added support for a progress bar in MEvtLoop and MReadTree
2099 (see the Analysis Window in Mars for an example)
2100
2101 - Fixed a bug in the package creation which disturbed the conversion
2102 between a mars version unpacked from a tar file and the repository.
2103
2104 - Changed the code to writer merpped (converted into root format)
2105 raw files, to get faster (around 10%)
2106
2107
2108
2109 *** Version 0.4 (2001/09/20)
2110
2111 - This release is made to compile on a root version >= 3.00
2112
2113 - Fixed a bug which causes MReadTree to read the first file only
2114
2115 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2116
2117 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2118
2119 - Added a task to write several container to a root file (MWriteRootFile)
2120
2121 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2122
2123 - Added calculation of the collection area (MMcCollectionAreaCalc)
2124
2125 - fixed some bugs in the Hillas calculation
2126
2127 - added filters to be able to control the task execution dependent on
2128 a parameter (for example: the number of level 1 triggers in a MC-file)
2129
2130
2131
2132 *** Version 0.3 (2001/04/23)
2133
2134 - Many demo macros added
2135
2136 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2137
2138 - Hillas Calculation added
2139
2140 - Standard image cleaning available
2141
2142 - MReadTree is now able to handle more than one file
2143 (Remark: of the same structure)
2144
2145 - Now we are able to display events in a first version of the
2146 Camera event display. To do this we must run the macro
2147 "macros/readCT1.C" to read data from CT1.
2148
2149
2150
2151 *** Version 0.2 (2001/01/24)
2152
2153 - First Implementation of a Gui to read the raw data. Start the
2154 gui with the command mars.
2155
2156
2157
2158 *** Version 0.1 (2000/12/20)
2159
2160 - First official release 0.1
2161
2162 - Changes:
2163
2164 + changed calling style of MRawPixelIterator from do...while to
2165 while-loop
Note: See TracBrowser for help on using the repository browser.