source: trunk/MagicSoft/Mars/NEWS@ 8392

Last change on this file since 8392 was 8392, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 87.3 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - general: The new class MGeomCamDwarf contains the camera geometry
6 for our prefered Dwarf camera and can be used to create general
7 geometries of roundish or hexagonal cameras.
8
9 - mars: The default cleaning is now Abolsute 8.5/4.0.
10
11 - mars: The resource file mars.rc now contains examples for MUX data
12
13 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
14 data containing only 10-bit information is still cooked down to
15 8-bit, by cutting away the lowest 8-bit.
16
17 - merpp: When reading raw data the data is now stored in a single
18 array. The lo-gain array is obsolete. The interface stays the same.
19
20 - callisto: Improved binning for the pulse position check histogram
21
22 - callisto: The code calculating the pulse position checknow takes
23 the pedestal into account
24
25 - callisto: The arrival time is now stored with full precision this
26 helps to get rid of artefacts in histograms. For the signal this
27 is not necessray because it is displayed in log-scale anyhow
28
29 - ganymed: The output files now contain run- and event-number for all
30 events, accessible as RunNumber.fVal and EvtNumber.fVal
31
32 - ganymed: Added a plot showing the source position in the camera also
33 for wobble mode
34
35
36
37 *** Version 1.0 (2007/02/16)
38
39 - database: Website to plot values from the database has been added.
40
41 - database: The rate of spark events as found by star is now kept
42 and the rate after cleaning is now with spark events subtracted
43
44 - general: The changes to the interpretation of phrases lead to
45 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
46
47 - general: Added example files how you can create your own calendar
48 (eg. as christmas present) with Mars. Just run
49 root macros/tutorials/calendar.C
50
51 - general: Added a possibility to display grouped data in the plotdb.C
52 macro (and similar macros). This allows to plot hourly, nightly,
53 weekly, monthly and yearly averages.
54 For more details see the plotall function of the macro
55
56 - general: fixed the error display of the camera display. It showed
57 wrong results.
58
59 - general: fixed a memory leak when reading many MStatusDisplays
60
61 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
62 between a spherical and a parabolic mirror
63
64 - callisto: We have a new pulse position check which takes the properties
65 of the extractor automatically into account. So no need to set
66 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
67 left is done. If possible the lo-gain extraction start and hi-gain
68 extraction end is changed accordingly. If no proper extraction range
69 can be set (hi-gain too much to the left) an error is raised.
70
71 - callisto: New swapped pixels have been found and corrected
72
73 - callisto: Redone the signal extraction this includes:
74 + Unified the algorithms to extract the pedestal for all pedestal
75 extractions done
76 + Unification of hi- and lo-gain into one array
77 + Unification of hi- and lo-gain extraction for Spline and
78 Digital Filter (means now exactly the same algorithm is used,
79 not a copy-and-pasted one)
80 + Store pedestal subtracted data in a common place
81 + Improved extraction algorithms. If the algorithms search a
82 maximum but don't find one they don't return the maximum anymore
83 + Improved the extraction such that a information for signal
84 and time which is consistent is returned
85 + replaced the numerical spline with a (not slower) analytical
86 solution
87 + Lowered the saturation limit from 250 to 245 to make sure that
88 we are far away in all pixels from problems with the clock-noise
89 + The start of the lo-gain extraction is calculated from the hi-gain
90 arrival time. In case of saturation an estimation is used.
91 + the hi-gain window was extended to slice 16. This allows extraction
92 of very late pulses in single pixels or of huge hadron showers.
93 + Now uses the lo-gain extraction range for pedestal extraction,
94 not the hi-gain range in the lo-gain
95
96 - callisto: New hi-/lo-gain calibration constants have been produced
97 for all periods from the statistic of the whole period. They are
98 now used automatically depending on the periods. The old constants
99 where deviation in avarega about 2%-3%. The constants are very
100 stable from period to period (<<1%) except for exchanged channels.
101 In a few cases the constants used so far were off by 1%-2% (maybe
102 temperature effects?)
103
104 - callisto: To gain obsolete space we do not write the
105 MPedestalFundamental anymore. Also calibration and bad pixel
106 treatment is not done for it anymore because it has never been used.
107
108 - callisto: Fixed a bug in the seuqence handling which caused the
109 light condition to be ignored
110
111 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
112 basically the same as "Cleaned" but the distribution devided into
113 the events fullfilling a spark cut or being rejected by it.
114 This cut can be changed from star.rc (see example inside) by
115 the "SparkCut" directive
116
117 - star: Star displays now the average individual pixel-rate (IPR) versus
118 time and the average discriminator threshold (DT) of all pixels.
119
120 - optim: fixed a problem with the optim-macros which was due to a bug
121 in the new phrase parsing
122
123 - ganymed: To get a nice FalseSource plot (instead of the all-information
124 debug plot displayed as a standard plot) use the context menu
125 somewhere between the two upper plots, click on "DrawNicePlot"
126 and enjoy the result. (It is the same context menu which contains
127 the other options)
128 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
129
130 - ganymed/optim/train: The cut program, trainings- and optimization
131 macros could run with less files found than expected from the
132 sequence-files. No the execution is stopped in this case.
133
134 - ganymed: now stores the dataset in the output file with all information
135 contained (as sequence number, sequence path, data path) so that the
136 used dataset file can be recreated complete from the output
137
138 - sponde: now also allows the uasge of random forest
139
140 - sponde: added a plot showing the cut efficiency
141
142 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
143 errors (eg. effecting the collection area) because the errors of the
144 two histograms were swapped in the calculation, which makes a difference
145 in the case the histograms contains weighted events. Aditionally the
146 totalarea was incorrectly taken into account, which results in too small
147 errors, which makes a difference at low statistics were the errors
148 or the collection area dominate.
149
150
151
152 *** Version 0.10.3 (2006/10/23)
153
154 - database: Implemented ObservationMode flag in websites.
155
156 - database: For sequences there is now also the stoptime available on the
157 websites.
158
159 - database: Removed ManuallyChanged flag from sequence-info websites,
160 as it is not needed anymore with the new sequence building algorithm.
161
162 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
163 Class for calculation of confidence intervals (upper limits).
164 Use model 3 or 4 for upper limit calculation for MAGIC observations.
165 Please read the class instruction of TRolke for more information.
166
167 - general: The programs now return 0xfe if the requested resource file
168 doesn't exist.
169
170 - general: Errors comming from root itself are now not output to
171 stderr anymore but to our default (colored) log-stream.
172
173 - general: Changed the interface to TFormula such that now everything
174 is parsed by TFormula, which should allow to use phrases even
175 without paranthesis correctly parsed.
176
177 - callisto: replaced the AdHoc number of effective integration slices
178 in the digital filter by an average of the correct number, averaged
179 over all possible set of weights. This also gives correct numbers
180 for the lo-gains which were totally wrong before.
181
182 - callisto: drastically reduced memory consumption by not storing
183 all intermediate calibration results in memory anymore (we might
184 write them into a file in the future)
185
186 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
187 debug plot displayed as a standard plot) use the context menu
188 somewhere between the two upper plots, click on "DrawNicePlot"
189 and enjoy the result. (It is the same context menu which contains
190 the "DrawAll" option)
191 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
192
193
194
195 *** Version 0.10.2 (2006/10/15)
196
197 - general: changed the building of the sequence files such, that
198 the source-/project name in case of wobble-sources is not the
199 source/project of the first data run anymore but the new generalized
200 wobble source/project
201
202 - general: Added some functions to MAstro to calculate sun and
203 moon properties
204
205 - general: Added two new macros (starvisday.C and starvisyear.C)
206 which allow to plot the visibility of several stars in one day
207 or of one star along one year
208
209
210
211 *** Version 0.10.1 (2006/10/11)
212
213 - general: HTML logging output was distorted... fixed.
214
215 - general: Changed the writing of the sequencefiles such that only
216 as many pedestal files as giving at least 1000 pedestal events which
217 are nearby the first calibration run are used as pedestal runs
218
219 - sponde: In the calculation of the collection area(s) and the
220 distribution for MOnte Carlo and estimated energy the error
221 calculation was wrong because root didn't take the errors
222 properly into account... fixed.
223
224
225
226 *** Version 0.10 (2006/10/10)
227
228 - general: all executables now check consistency of the root version
229 installed with the root version used for compilation. The return
230 code in this case is 255.
231
232 - general: The algorithm to build seqeunces has been redesigned
233 completly. It is now more flexible in terms of a resource file
234 resources/sequences.rc which can be used to partly overwrite
235 the default algorithm and defined the important part of the
236 algorithm. It also takes correctly into account several ways
237 of taking wobble-data. Currently the new algorithm doesn't take
238 the number of pedestal events anymore into account (so a sequence
239 could have much less than 1000 pedestal events and data runs are
240 no-more used instead)
241
242 - general: a lot of small changes to make the code compatible with
243 root 5.12/00 and gcc 4.1
244
245 - general: Fixed some warnings thrown if more warnings are switched
246 on in the compiler
247
248 - general: Added a function to MMath which returns the Median of
249 the distribution abs(y[i]-median) but at 68:32 division instead
250 of 50:50, which is somehow the median counterpart of the rms.
251
252 - general: MAstroCatalog allows now to read calatog files (as bsc5)
253 even if they are compressed with gzip (recommended compression
254 is with "-1")
255
256 - showplot:
257 + batch mode creation of image files now works with root 5.12/00
258 + added support for writing bmp (though it never produces
259 bmp which can be read by programs like xv or gimp)
260 + added support for xml
261 + added new option to start the display with a different size, by
262 --display-width=nnn or --display-height=nnn
263 + added options to define the canvas size when the display is started
264 --canvas-width=nnn or --canvas-height=nnn
265 the option can also be used for batch-mode conversion
266 + added an option which automatically fits the display size to the
267 desktop-size: --auto-size
268
269 - merpp: didn't recognize files with the extension .raw.gz - fixed.
270
271 - merpp: allow the reports to have 1000ms due to a bug in the camera
272 program.
273
274 - callisto: New swapped pixels have been found and corrected. For
275 details see MRawRunHeader::FixAssignment()
276
277 - callisto: Callisto now raises an error if one of the input files could
278 not be opened.
279
280 - callisto: In some rare cases it could happen that in the signal
281 extraction of the digital filter the extractor returned nonsense
282 results due a wrong initializion of a variable (this happens in
283 cases in which the extracted signal is exactly zero or the
284 digital filter couldn't slide because of a too small extraction
285 window, which could happen in the lo-gain extraction)
286
287 - callisto: The lo-gains have been marked as valid in some cases
288 when they got not extracted at all (deltsumlo=deltatimelo=0) because
289 the allowed extraction range (fLoGainLast-fLoGainFirst) was
290 smaller than the number of slices (fLoGainWindowSize) needed
291 by the lo-gain extractor
292
293 - callisto: Updated absolute calibration constants (muon calibration)
294
295 - callisto: fixed a bug which caused the hi-gain saturation not
296 to be handled properly in the spline (the position of the
297 saturation was calculated incorrectly)
298
299 - callisto: fixed a bug which gave weird results if hi- _and_
300 lo-gain could not be extracted properly. In some cases hi-
301 and lo-gain have not been extracted at all and the random result
302 got calibrated. In other cases the hi-gain was saturating and the
303 lo-gain has not been extracted. For this a completly arbitraty
304 scale factor was applied to the result from extracting the
305 charge of the saturating hi-gain.
306
307 - callisto: improves handling of extracted signal if lo- and/or
308 hi-gain could not be extracted properly. If no appropriate
309 calibration of either the signal or the arrival time is possible
310 the pixel is now markes as unsuitable instead of estimated.
311
312 - callisto: Fixed a problem in the spline extraction which gave
313 weird results if the signal was extracted from the first (and
314 highest) slice (as a workaround extraction from the first
315 slice has been forbidden)
316
317 - callisto: Fixed a bug regarding the use of the QE which doesn't
318 effect the result because the default is used anyhow.
319 (The bug was there since 14/07/2005)
320
321 - callisto: Changed the default for fgLoGainStartShift to -2.4
322
323 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
324 factors to be always 10 for all pixels as soon as the first
325 calibration update has happend.
326
327 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
328 was off by more than one slice (which gives wrong values for
329 pixels which have saturated the hi-gain) This was a problem
330 mainly for timing studies, not so much for the automatic standard
331 analysis. Also the values for the Spline have been changed slightly:
332 + Digital Filter from 1.70 to 0.95
333 + Spline from 1.39 to 1.30
334 The numbers were sorted out by an extensive test in the
335 test-database.
336
337 - callisto: Removed the tab showing the average calibrated arrival
338 time. It never gave useful information.
339
340 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
341 lo-gain pulse for data pulses if hi- and lo-gain have saturated
342 and both were extracted because the hi-gain was above the
343 LoGainSwitch.
344
345 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
346 lo-gain pulse position (after application of LoGainOffset, which
347 means in the ideal case it is 0) for data pulses if hi- and lo-gain
348 have saturated and both were extracted because the hi-gain was above
349 the LoGainSwitch.
350
351 - callisto: After extensive tests a new threshold level for determination
352 of the pulse position has been found at 50phe. This is due to the
353 fact that for lower pulses the arrival time changes its average
354 behaviour dramatically. It tends to the average of the extraction
355 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
356
357 - callisto: Added two more plots to the calibration part. The average
358 extracted signal and the average extracted arrival time as
359 extracted by the signal extractor (This can help debugging problems
360 because it doesn't involve a fit)
361
362 - star: changed the fit for the effective on time such that initial
363 values are calculated automatically now instead of using build
364 in values. This makes the fit more indepedant of the underlaying
365 rates. With a test of ~350 sequences in the test database it could
366 be shown that the new fit gives the same result +/-1sek.
367 The highest deviation was +5s the lowest -10s. You can now control
368 the bahaviour with two resource values:
369 MHEffectiveOnTime.FistBin: 3
370 MHEffectiveOnTime.NumEvents: 12000
371 Use FirstBin=1 and NumEvents=120 to fit the effective on time
372 from the resulting gamma candidates
373
374 - star: The Center histogram in MHHillas is now by default displayed
375 with the colz draw-option
376
377 - ganymed: now produces valid error codes if failed
378
379 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
380 with the option "hadronness" instead of "area" or "both" if
381 you want to use both cuts. The hadronness cut includes a fixed
382 cut in hadronness (index 8) and a fixed cut in size (index 9).
383
384 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
385 the M3Long of the anti source to be not properly evaluated
386 (actually is was evaluated as a unique random number) in case
387 of optimization with anti-theta cut switched on. This might have
388 lead to improper, but not necessarily wrong, optimization results.
389
390 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
391 how to use random forest
392
393 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
394 ganymed_onoff.rc. Seems to be unintentional that they were different.
395
396 - sponde: Since the introduction of the possibility to define a
397 normalization energy instead of using the integral the default
398 was not using the integral anymore but a normalization energy of
399 1GeV. It is now the integral again.
400
401 - sponde: Fixed a problem in the weighting which did not allow
402 a MC slope of -1.
403
404
405
406 *** Version 0.9.6 (2006/05/24)
407
408 - general: changed the binning of the azimuthal profile of the camera
409 such that it is aligned with the 60deg boundaries.
410
411 - merpp: better handling of problems with the TH, TD part of the
412 CC-REPORT for files older than 200507190 and 200412210
413 respectively
414
415 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
416
417 - merpp: implementd latest changes in starguider reports (sinc 9th May)
418
419 - callisto: if an arrival time is extracted outside the fadc range is
420 was set to the boundary before. Now a random number is assigned
421 instead to avoid unfortunate coincidences of arrival times just
422 by this arbitrary value.
423
424 - callisto: added a new option to callisto.rc which allows
425 to set the maximum arrival time difference allowed for the
426 badpixel algorithm to determin whether a pixels belongs to a shower:
427 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
428
429 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
430 to 0.9 as suggested by Stefan due to a recent study on the fraction
431 of pixels surviving the image cleaning
432
433 - callisto: switched off error in case of "pulse is too much to the left"
434
435 - callisto: The extraction window is not adapted anymore. This means that
436 the pulse is extracted from the full range. The draw-back is that the
437 background (pedestal) will become slightly higher. Switching on/off
438 the PulsePosCheck in the callisto.rc only effects filling the
439 histograms.
440 WARNING: If the pulse is too much to the left data is calibrated!
441 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
442 in the database to make sure that your data is valid!
443
444 - star: Show also the number of stars correlated correctly by the
445 starguider
446
447 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
448 than one off-source region in wobble-mode. To use it add the following to
449 your ganymed_wobble.rc:
450 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
451 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
452 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
453 + Cut1.ThetaCut: None
454 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
455
456 - ganymed: in the case the latest report is older than a default (currently
457 one minute) and the current report will be skip the starguider
458 correction and calibration will be reset. The maximum age can be
459 setup from ganymed.rc by (minutes):
460 MPointingDevCalc.MaxAge: 1.5
461
462 - ganymed: A first implementation showing all size-bins for the theta-sq
463 resp. alpha-plots in a single tab automatically
464
465
466
467 *** Version 0.9.5.1 (2006/05/05)
468
469 - general: Added a new option "zdiff" to the Makefile which runs
470 "cvs diff" as "make diff" would do, but with compression
471
472 - general: accelerated MTFillMatrix (used for eample in all training
473 and optimization macros) by skipping some obsolete calles in the
474 eventloop the first and second loop could be accelerated by ~20%
475
476 - general: Added a missing feature in the MFilterList class which
477 prevented MFEnergySlope from working correctly in trainenergy.C
478
479 - general: Accelerated the random forest training and usage a bit
480
481 - merpp: Adapted to new raw data file format version 6
482
483 - merpp: fixed a problem with reading the starguider reports
484 after 6.3.2006
485
486 - callisto: At some times six pixels had to be exchanged manually in the
487 data. If the pixels to be swaped are both not found, an error was raised
488 and calibration was stopped. Now it is assumed they are intentially not
489 mapped and the Error has been changed to a Warning.
490
491 - star: Added new image cleaning based on the arrival time of the shower.
492 The new cleaning can be accessed using the parameter "Time" instead of
493 the the old one (like "Absolute) in the star.rc-file.
494 Recommended parameters:
495 + MImgCleanStd.CleanLevel1: 8.2
496 + MImgCleanStd.CleanLevel2: 5
497 + MImgCleanStd.CleanRings: 2
498 + MImgCleanStd.KeepSinglePixels: No
499
500 - star: Simplified the calculation of the effective on time. By letting
501 the fit start in the third bin the result should become more stable.
502 The fit quality is now ignored for the theta-plot which is not used
503 in the analysis later. Still better pre-cut which, for example,
504 remove events triggered by car-light (rate changing on a short
505 time-scale) are missing.
506
507 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
508 for optimization (kWeakSource) which is suggested by the Berlin
509 people for weak sources.
510
511 - macros: plotdb.C:
512 + if no dataset and no time-interval is given only sequences with
513 an effective on-time above five minutes are plotted anymore
514 + added a new tab "RelTime" displaying the relative on-time
515 (effective on-time divided by the observation time)
516
517 - macros: optim*.C: by skipping some obsolete calles in the eventloop
518 the optimization became a lot faster
519
520 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
521 To display them just delete the pads displayed on top.
522
523 - ganymed: fixed a bug which could cause strange behaviour in wobble
524 mode if no starguider information was available due to an incorrect
525 initialization of the starguider calibration
526
527 - ganymed: The scale region in the False Source Plot (MHDisp) can now
528 be changed from within the plot. It can also be setup from the
529 resource file using:
530 + MHDisp.fScaleMin: 0.325
531 + MHDisp.fScaleMax: 0.475
532
533 - ganymed, showplot: Fixed a problem with the fit to the off-data
534 (HistOff) which could cause a time lag or an inifinite loop.
535 The bug did not effect the results at all.
536
537 - sponde: Added a new tab showing the effective collection area after
538 trigger (including the software trigger)
539
540 - sponde: MMcSpectrumWeight has a new option which allows to define
541 the scaling factor not by the integral of the events but at
542 a defined energy:
543 e.g. MMcSpectrumWeight.NormEnergy: 200
544
545 - MTFillMatrix, sponde: by skipping some obsolete calles in the
546 eventloops the loop could be accelerated by ~20%
547
548
549
550 *** Version 0.9.5 (2006/03/13)
551
552 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
553 and added the standard Disp-parametrization
554
555 - macros: added a new macro datacenter/macros/plotstat.C allowing
556 to plot statistics about the data processing
557
558 - macros: added a new macro to plot the muon correction coefficients
559 versus period (macros/plot/mucal.C)
560
561 - showplot: path inflation for ganymed files was broken
562
563 - callisto: Fixed an important bug. When the number of saturating pixels
564 were calculated the bad pixel information already available from the
565 calibration was ignored. This yields wrong values in case pixels
566 are broken and saturate all the time or randomly.
567
568 - callisto: Updated Muon calibration constants. Spline data now also uses
569 different values for different periods
570
571 - star: The time-evolution shown in the effective on-time plot now displays
572 the axis range (if there are no holes it should be similar to the
573 effective on-time)
574
575 - star: Added two new image parameters:
576 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
577 the three pixels next to the center of gravity and the size
578 + MNewImagePar.fConcCore: The ratio of the signals of all
579 pixels inside or touching the ellipse and the size
580
581 - ganymed: now stops in requested source isn't found in catalog file
582
583 - ganymed: Many improvements to the phi-plot in wobble mode:
584 + with a template the ideal background is displayed
585 + a possible camera inhomogeneity is taken into account
586 + the anti theta cut is better supported
587 + the phi cut is automatically calculated from the theta cut
588 See the examples in ganymed_wobble.rc for more details.
589
590 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
591 times the bin-width instead of the absolute energy
592
593 - ganymed: New cuts for on/off and wobble mode
594
595 - ganymed: The smearing of the False Source plot has been increased
596 to 0.06
597
598 - ganymed: The starguider calibration can now be changed from the
599 resource file.
600 See the examples in ganymed*.rc for more details.
601
602 - ganymed: added a new option for on-/off-observations
603 MJCut.RandomSourcePosition
604 If switched on the distribution of observation time of the source
605 position in the camera is calculated from the on-data and randomly
606 applied with this distrbution to the off-data.
607
608 - ganymed: by skipping some obsolete calles in the eventloop the
609 first and second loop could be accelerated by ~20%
610
611 - ganymed: The default in ganymed_onoff.rc is now to determin the source
612 position in the off-data randomly according to its distribution in the
613 on-data.
614
615
616
617 *** Version 0.9.4.3 (2006/02/13)
618
619 - general: Fixed a bug in most of the programs which prevented the
620 compile date in the startup message to be displayed
621
622 - general: Simplified program calls. The following abbreviations
623 are now possible:
624 showlog callisto 55599
625 showplot signal 55599
626 star 55599
627 callisto 55999
628 ganymed 2
629 In this cases the corrsponding root-, log-, sequence- or dataset-
630 filename is automatically compiled using the default datacenter
631 paths ("/magic/*")
632
633 - general: Fixed a long outstanding bug which made axis tick marks
634 disappear if MDataFormula was used (eg. abs(x))
635
636 - general: Updated MMath with new functions to calculate the results of
637 a exponential, logarithmic and powerlaw fits analytically.
638
639 - general: Updated some macros with comments:
640 + macros/optim/optimdisp.C
641 + macros/optim/optimenergy.C
642 + macros/optim/optimwobble.C:
643
644 - general: MTFillMatrix (the class to fill one or two MHMatrix from
645 files) now allows adding a pre-cut like in the optimization. E.g. this
646 is useful to perform g/h-separation cuts before training the random
647 forest.
648
649 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
650 correctly assigned in the raw data assignement table. A fix to correct
651 the assignment tabel have been implemented.
652
653 - general: MAstroCatalog now allows rotating of the sky-grid and stars
654 by 90, 180 and 270 deg.
655
656 - general: the macro plotdb.C now allows to highlight sequences belonging
657 to a datset. For more details see the descritions in the macro.
658
659 - StatusDisplay: Fixed the algorithm to calculate the size ratio
660 of the display, it gave wrong results espacially for big sizes.
661 Now the embedded canvas should always have a ratio width/height=3/2.
662 The "Size" options have been updated with values fitting the 3/2
663 size ratio.
664
665 - RanForest:
666 + Updated the random forest classes to support also the
667 regression method implemented by Thomas H.
668 + added new tutorial macro how to train the random forest
669 for energy estimation (macros/optim/rfenergyest.C)
670 + new classes to train the random forest (still in development)
671 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
672 + new tutorial macros for random forest training in macros/train
673 trainenergy.C, traindisp.C, trainseparation.C
674
675 - mars: now allows to setup a cut in the resource file mars.rc to choose
676 the events to be displayed, eg:
677 Cut.Condition: {0} && {1}
678 Cut.0: MHillas.fSize>100
679 Cut.1: MHillas.fSize<900
680
681 - merpp: Made aware of the new .rep format 200510250. This includes
682 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
683 the discriminator thresholds (MCameraTD) and the disciminator
684 delays (MCameraTD). All of them come with the CC report and are therefor
685 written to the CC tree.
686
687 - callisto: fixed a bug in the calculation of the arrival times in
688 the Digital Filter. They were all shifted by the same amount
689 fHiGainFirst. This caused an offset in the order of the position of
690 the left border of the extraction window in the times calculated
691 from high-gain and from low-gain. The bug effected only the absolute
692 arrival times. The bug was there since 30.1.2005.
693
694 - callisto: Changed the ExtractionWindow for the pulse position check
695 such that the camera inhomogeneity becomes as less as possible and
696 comparable to the pulso position check switched off. More details
697 on the study will be given at our result web-page.
698
699 - ganymed: ganymed.rc, ganymed_onoff.rc:
700 changed to new cuts trained with 1ES1218 and Crab-data
701 for maximum sigma*log10(excess)
702
703 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
704 a new option was implemented to estimate Disp (CalcDisp)
705
706 - ganymed: Implemented two new options which allow
707 to overwrite the default path to search for the sequence files
708 --ins=/magic/sequences
709 and where to search for the image data
710 --ind=/magic/data/star
711
712 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
713 dx/dy from the resource file by
714 MSrcPosCorrect.Dx
715 MSrcPosCorrect.Dy
716
717 - ganymed: fixed reading the source catalog. Only as many chars
718 as the requested source name had were compared (If a source
719 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
720 were requested it could happen that the coordinates of
721 "1ES1218" were read) The source coordinates are now printed
722 in addition to its name to the logging output.
723
724 - ganymed: changed the background fit in the case of a ThetaSq function
725 from a polynomial to a exponential, this should give a big improvement
726 for on-only analysis'
727
728 - ganymed/sponde: Calculation of the error of single size-/energy-
729 bins now uses Li/Ma (5) instead of LiMa (17)
730
731 - sponde: Added a plot E^2*dN/dE
732
733 - sponde: The energy estimator plot should now show values like
734 they are commonly used.
735
736 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
737 (a powerlaw with cutoff didn't work before)
738
739
740
741 *** Version 0.9.4.2 (2005/10/01)
742
743 - general: added new tutorial macro macros/tutorials/threshold.C:
744 how to calculate the threshold
745
746 - general: added a new game. Start it from the interpreter with
747 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
748 and MagicReversi)
749
750 - general: neighbor pixels in MGeoms are now sorted clockwise
751
752 - merpp: made aware of new format 20050829-0
753
754 - callisto: New scale factors from muon analysis, stored in new
755 resource file resources/calibration.rc
756
757 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
758 the eventloop if something went wrong. This is necessary for the
759 automatic processing
760
761 - callisto: Implemented a new treatment for the time information
762 developed by S.Ruegamer, this should give much better response than
763 the old very primitive algorithm. This is especially important
764 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
765 treatment was buggy! As neighbor pixels to interpolate the
766 arrival times always the pixels 0 to 5 were taken)
767
768 - callisto: In addition to the new treatment of arrival times the
769 decision of the treatment whether a pixel contains shower
770 information or not is used to improve the signal interpolation
771 further. Previously interpolated pixels showed a non-zero signal
772 do the peak searching signal extractors. Having a signal pixel
773 beside raised the signal above the cleaning level. Thus the
774 pixel survived cleaning to often but with a too low mean signal.
775 By replacing empty pixels with a gaus (mean and rms from the
776 corresponding Area entries in MPedPhotCam) this effect can
777 be supressed.
778
779 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
780 got lost when the events were stored by the calibration... fixed.
781 (This was no problem for normal image cleaning because the pixel
782 content was artificially set to 0 not surviving standard cleaning
783 algorithm)
784
785 - callisto: Fixed a bug which caused the random and peak-search pedestal
786 extracted with an extractor to be exchanged for the first (roughly)
787 500 events (*Extractor and *ExtractorRndm).
788 (They were simply exchanged in callisto.cc) This bug might have been
789 introduced in Mars 0.9.4 when the order of calculation of the two
790 types of pedestal in callisto got exchanged. The bug only effects
791 the first seconds of data of each sequence.
792
793 - star: Taking the arrival time of Muons into account the calculation
794 of the parameters could be made independant of the noise
795 (pedestal rms). The dependance was due to the bias of the peak search
796 extractor. Now only a ZA dependamcy is left which is not yet fully
797 understood.
798
799 - ganymed: The sequences were still not sorted correctly in any case,
800 because they were sorted by the full qualified path name. Now they
801 are sorted by their sequence number.
802
803 - ganymed: new values for the spark-event-cut
804
805 - sponde: required missing MEnergyEst from ganymed.root... fixed.
806
807
808
809 *** Version 0.9.4.1 (2005/08/18)
810
811 - callisto: fixed some problems with the calibration in case of
812 inteleaved events. Therefor the final and some intermediate
813 fits are skipped which would take place on partly filled #
814 histograms and gave wrong results or failed completely.
815
816 - callisto: If the intermediate finalization of the histograms
817 calculating the mean charge of the calibration signal fails
818 it is counted now and printed in PostProcess of MCalibCalcFromPast.
819
820 - ganymed: Fixed some bugs which caused problems in On-only mode.
821 Still the false source plot doesn't give reasonable results.
822
823
824
825 *** Version 0.9.4 (2005/08/05)
826
827 - general: Fixed the ZA binning. It did not correctly fit the
828 MC binning
829
830 - general: Added a class to correct for the missfocussing in
831 April (MSrcPosCorrect)
832
833 - general: Random Forest energy estimator should now work properly
834
835 - general: MHCamera now displays the profiles in deg instead of mm
836
837 - general: MH::SetPalette offers a lot of new palettes
838
839 - general: MHillas - the case of CorrXY==0 is now handled properly
840
841 - general: implemented the possibility to change the line and
842 marker style of a sky-grid drawn by MAstroCatalog
843
844 - general: Runs in sequences and datasets are now automatically
845 ordered (it is assumed that the order of their filenames correctly
846 represents the order of observations) to ensure correct reading
847 of the subsystem data
848
849 - general: Runs cannot be added to a sequence twice anymore. Also
850 Sequences cannot be added twice anymore to a dataset.
851
852 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
853 It gave wrong results by 1./2pi
854
855 - showplot: got a new option to start a root interpreter, too
856
857 - mars: now displays a rough estimate of Disp and the third moment
858
859 - mars: now displays the event time MTime if available
860
861 - mars: show muon parameters graphically
862
863 - mars: now the file to open can be given as commandline
864 argument
865
866 - merpp: Added support for new arehucas version >= 200507190
867 implementing values for three temperature sensors in the
868 counting house (MCameraAUX) and the name of the HV settings file
869 (MCameraHV).
870
871 - merrp: Also fixed some problems with wrong versions numbers stated
872 by arehucas and implemented some fixed for old versions (<200407070)
873
874 - callisto: MCalibrationHiLoCam can now be printed from its context
875 menu, eg in the TBrowser
876
877 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
878 - 1.39 (MExtractTimeAndChargeSpline)
879 - 1.40 (MExtractTimeAndChargeDigitalFilter)
880 This is important mainly for timing studies.
881
882 - callisto: Changed limits in MHCalibrationChargeCalc from
883 - -100.125 to -98 (fgChargeHiGainFirst)
884 - 1899.875 to 1902. (fgChargeHiGainLast)
885 - -100.25 to -99 (fgChargeLoGainFirst)
886 - 899.75 to 901. (fgChargeLoGainLast)
887 Introduced new limits:
888 - fgNumLoGainBlackoutLimit: 0.05
889 - fgLoGainBlackoutLimit: 3.5
890 - fgLoGainPickupLimit: 3.5
891
892 - callisto: The handling of automatic weights for the digital filter
893 has been improved. There are now new calibration weights special
894 for Monte Carlo calibrations.
895
896 - callisto: Updated Muon scale with latest results (1% difference
897 for most data, 5% for Mar/Apr'05)
898
899 - callisto: use a new criterium to exclude bad pixels: If the high-gain
900 was saturated and the blackout-events in the low-gain exceed the
901 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
902 This excludes those pixels which have a saturating high-gain
903 channel, but the low-gain switch does not switch often enough
904 to make the distribution reliable.
905
906 - callisto: fix a bug counting the number of saturated events. Up to now,
907 the number of saturated slices was counted (which is one for a not too
908 high number), but for some (pathological) pixels, many more slices
909 saturated and produced wrong limits.
910
911 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
912 + MCalibrationRelTimeCam.CheckFitResults: Yes
913 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
914 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
915 + MCalibrationRelTimeCam.CheckOscillations: Yes
916
917 - callisto: introduce max. number of events for intercalibration,
918 the rest gets skipped. Default: 4096
919 The calibration causes too many un-reliable pixels if more
920 than about 5000 events are treated (@500 Hz) because of the
921 mode hopping of the VCSels. However, in the past, some
922 calibration runs have been taken (erroneously) with more
923 than 5000 events, especially the intensity scans where
924 a good precision is needed.
925
926 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
927 photo-electrons for the spline extractor by 1-2% (correctly).
928
929 - callisto: The intercalibration is now done using a full f-factor
930 method instead of a simple update. This makes things slower but
931 more reliable in terms of gain-fluctuations and sudden VCSEL gain
932 changes.
933
934 - callisto: MPedestalY3 now uses the same extraction range as the data
935 as calculated by MPedestalY2
936
937 - callisto: A check of the fraction of allowed unsuitable (10%) and
938 unreliable (30%) pixels has been addded when the conversion is
939 calculated from interleaved events
940
941 - star: fixed a bug which caused MEffectiveOnTime containers not to
942 be written. In the worst case they were skipped almost all, in the
943 best case they were all ok. It depends on how often the new value
944 was assigned just with an event which was skipped later by another
945 task
946
947 - star: new histograms MHPointing and MHRate
948
949 - star: New tab (Currents) displaying the time evolution of the mean
950 DC currents
951
952 - star: New tab (MeanRms) displaying the time volution of the mean
953 Pedestal Rms
954
955 - star: Output now contains MReportStarguider
956
957 - star: Improved muon analysis. Due to the absense of a constant
958 for the gaus fit for arc width and the fact that the arcwidth
959 plot was a histogram instead of a profile the resulting psf
960 became pedestal rms dependant
961
962 - ganymed: added new plot (MHPhi) for wobble mode as described in
963 http://www.astro.uni-wuerzburg.de/results/ringmethod/
964
965 - ganymed: corrects now (correctly?) for the misspointing in
966 May/April 05
967
968 - ganymed: Two new default templates for ganymed.rc are avilable:
969 ganymed_onoff.rc and ganymed_wobble.rc
970
971 - ganymed: The first version of MFMagicCuts has been released
972
973 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
974
975 - ganymed, sponde: There are two new options to determin the number
976 of bins for the signal region (NumBinsSignal) and the number of
977 total bins (NumBinsTotal) in the MHThetaSq histogram
978
979 - ganymed: optimized palettes for MHDisp
980
981 - ganymed: Fixed an important bug when using ThetaSq as fit function:
982 The result for the sigma of the gauss(sqrt(x)) fit was a factor
983 sqrt(2) to large
984
985 - ganymed: The false source plot (MHDisp) is now based on Disp
986 and a background model determined in the first loop is
987 subtracted
988
989 - ganymed: MFMagicCuts are now available in the cvs. The correct
990 solution for the disp ambiguity problem is now calculated using
991 the third moment. The third moment cut therefor is skipped.
992
993 - ganymed: Output now contains "Disp [MParameterD]" which sign is
994 already determined by the third moment along the major axis and
995 so its actual sign is aligned along the major axis of the shower.
996
997 - ganymed: If starguider data is available it is taken into account
998 when calculating the source position. This is especially important
999 for wobble data at high zenith angles and culmination data.
1000
1001 - ganymed: If available the starguider data is taken into account as
1002 good as it is possible without a starguider calibration. To switch
1003 it off add
1004 MPointingDevCalc.MaxAbsDev: -1
1005 to your ganymed.rc
1006
1007 - sponde: the zenith angle distribution is now weighted instead of
1008 choosen by default. This gurantees higher statistics in the highest
1009 and lowest energy bins. To switch this behaviour off use...
1010
1011 - sponde: now automatically displays the energy threshold
1012
1013
1014
1015 *** Version 0.9.3 (2005/06/03)
1016
1017 - general: MMcEvt now derived from MMcEvtBasic which should
1018 have no influence on compatibility with older camera files
1019
1020 - general: Implemented a new option to MReadReports which allows
1021 to force reading of the first event of some trees (eg. Drive-tree)
1022 before any other tree.
1023
1024 - general: Made a fix to MPointingPosCalc which assumes that the
1025 run-type is real-data if Process is called before ReInit, such
1026 that also the very first Drive-events in a run are treated
1027 correctly.
1028
1029 - shoplot now displays the filename in the title bar of the window
1030
1031 - merpp: new options: --auto-time-start --auto-time-stop which
1032 allow to cut updating with slow-control at the start- or
1033 (previousle --auto-time only allowed: and) stop-time of
1034 the run stored in the runheader.
1035
1036 - callisto: changed default of fgFallTimeHiGain in
1037 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1038 already set as default in callisto_Dec04Jan05.rc
1039
1040 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1041 now changes the filename for new weights automatically for
1042 cosmics, MC and for different calibration colors.
1043
1044 - callisto: a problem with the order of some code cause the
1045 name of the weights file in MPedestalY2 to be ignored.
1046 Wrongly the calibration_UV weights were used instead
1047 of the cosmics weights set in callisto.rc.
1048
1049 - callisto: should allow ct1 pulser data when the color is
1050 explicitly set also for pretty new runs
1051
1052 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1053 to introduce an additional scale factor (should be around 1)
1054 to adapt for slight deviations in different extractors from
1055 the MC calibration. For MC calibrations the scale factor
1056 is fixed to 1
1057
1058 - callisto: MFCosmics should handle very high signals a bit
1059 more accurate now
1060
1061 - callisto: when calculating the mean pedestal rms for different
1062 pixel sizes or sectors also kUnsuitableEvt is now taken into
1063 account - not only kUnsuitableRun
1064
1065 - callisto: '-raw' option is now the default
1066
1067 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1068 This has the advantage that mean values in the calibration (eg
1069 arrival times) are calculated more accuratly.
1070
1071 - callisto: In the resource file callisto_Dec04Jan05.rc
1072 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1073
1074 - callisto: new Hi-/Lo-Gain intercalibration constants
1075 hilocalib_sp1.root and hilocalib_sp1_mc.root
1076
1077 - callisto: changed default for MJPedestalY2.MaxEvents
1078 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1079
1080 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1081 has changed from 9.0 to 6.0. This is necessary to exclude two very
1082 ringing pixels in September which - when kept - destroy the image
1083 cleaning around them (Markus G.)
1084
1085 - callisto: (!) The Muon analysis of all data taken so far has
1086 suggested that different extractors give slightly different
1087 absolute results after calibration, due to there different
1088 handling of the calibration- and cosmics pulse shape. Although
1089 the over all calibration seems to be a bit to pesimistic (or
1090 the MC seems to be a little bit - 3-5% - too much attenuated).
1091 There for correction factors have been introduced which correct
1092 the calibration constants by
1093 0.956937799 for Digital Filter (callisto.rc)
1094 and
1095 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1096 calibration. The main advantage is, that both data types can
1097 be easily analysed together and compared to the same MC sample.
1098 The factors are choosen such, that the reference is now a
1099 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1100
1101 - star: fixed a bug which caused the first bin of the histograms
1102 vs time to disapear in PostProcess. This gave wrong results
1103 on the screen. The output and all following programs not
1104 directly accessing the histograms haven't been affected
1105
1106 - star, ganymed: Made sure that always the first Drive-tree event
1107 is read and Processed before the first data event was read.
1108
1109 - ganymed: implemented the possibility to replace the standard
1110 false source plot with a different one. For example: If
1111 you want to use a Disp based FS plot use the resource:
1112 NameHistFS: MHDisp
1113 For details about the requirements of these plots look
1114 at the corresponding classes
1115
1116 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1117 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1118 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1119 case MAlphaFitter is setup correctly. For On-Only optimization
1120 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1121 RunOn() instead of Run(). For energy estimation MJOptimize
1122 has been replaced by MJOptimizeEnergy
1123
1124 - sponde: The input MC spectrum can now be weighted to fake a
1125 different spectrum. This is done via MMcSpectrumWeight. For
1126 more details see the class description and sponde.rc
1127
1128 - sponde: The paremeter comparsion plots are not scaled by
1129 their entries anymore. Instead the MC plot is scaled by using
1130 the result spectrum of the analysis. If the input MC spectrum
1131 and the result spectrum has different slopes the absolut
1132 normalization is normally wrong.
1133
1134
1135
1136 *** Version 0.9.2 (2005/05/20)
1137
1138 - general: Changed the default paths for calibrated data and image
1139 files. (The implemented access to these files doesn't yet exist)
1140
1141 - general: support for MRunIter has been removed from the job classes
1142 (use the setter functions of MSeqeunce instead)
1143
1144 - general: ProcessFile has been renamed to Process in all job classes,
1145 because ProcessFile is missleading
1146
1147 - general: The storage of the palette in MHCamera is now possible
1148
1149 - general: new bits describing unsuitable and unreliable pixels have
1150 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1151 kDeadPedestalRms, kFluctuatingArrivalTimes
1152
1153 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1154 versions newer than V200404070
1155
1156 - general: support for cc file versions newer than V200504130. Added
1157 support for active loads (MCameraActiveLoad) and central pixel
1158 (MCameraCentralPixel)
1159
1160 - general: added new histograms for image parameters versus size
1161 (MHVsSize)
1162
1163 - general: The eventloop now automatically calls PrintStatistics
1164
1165 - Status Display: Improved support for printing:
1166 + A default can now be set in .rootrc (for more details see
1167 MStatusDisplay::PrintPS)
1168 + A print dialog is opened so that printer and command line
1169 can be canged
1170
1171 - showlog: improved such that it handles different verbosity levels
1172 more accurate now. This mean you can suppress output when
1173 using showlog.
1174
1175 - showplot: improved
1176 + The new graphics formats have been implemented
1177 (pdf, svg, png, jpg and xpm)
1178 + Implemented an interface for printing. Because you can change
1179 the printing command from the command line you can use all
1180 the nice postscript tool. To print a booklet for example call:
1181 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1182 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1183 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1184
1185 - callisto: fixed a bug in the recognition of the calibration bit
1186 pattern. Concerns only intensity calibration. (The strength of the
1187 intensity has been updated in some cases)
1188
1189 - callisto: add a filter against PIN Diode events when running over
1190 calibration runs since some of the recent calibration runs have
1191 been taken with Pin Diode.
1192
1193 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1194 39943, 44833 in the calibration (MCalibColorSet)
1195
1196 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1197 been set to 1e-18 in callisto_Dec04_Jan05.rc
1198
1199 - callisto: in callisto_Dec04Jan05.rc: set value for
1200 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1201 statistics for the calculation of the mean pulse time
1202 of the cosmisc
1203
1204 - callisto: the charge limit in the calibration has been raised
1205 from 2.5 to 4.5
1206
1207 - callisto: new setup read from callisto.rc
1208 + MCalibCalcFromPast.fNumEventsDump
1209 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1210 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1211
1212 - callisto: MExtractTimeAndChargeSpline extractor:
1213 + The integration ranges were shifted by 0.2 FADC slices to the right.
1214 + unreliable handling of floating point values caused different
1215 results on different platform or with different compiler options:
1216 The new algorithm is numerically exact and more accurate because
1217 it doesn't calculate the integration position by multiple times
1218 adding the step-size (which results in numerical uncertanties
1219 exspecially if multiplied with large numbers)
1220 + A lot of fixes have been introduced which effects integrating the
1221 spline at the edges of the valid range. In this case any memory
1222 was randomly accessed. This behaviour can be tested replacing
1223 all MArrayF by TArrayF which perform a range check (but of course
1224 they are a lot slower)
1225 ! No result obtained with the Spline before can be trusted! Due to
1226 random memory access it might by completely random!
1227
1228 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1229 + extraction range in the high gain to 4.
1230 + weights file to cosmics_weights46.dat
1231
1232 - callisto:
1233 + introduce the check for fluctuating arrival times.
1234 + set charge limit to from 2.5 to 4.5
1235 + introduce asymmetric exclusion due to "deviating number of phes":
1236 Default: -9.0 +4.5
1237 + make deviating number of phes unsuitable (see David's findings).
1238
1239 - callisto: fixed the display of unsuitable pixels. The old change
1240 to a real profile in MHCamera broke it.
1241
1242 - callisto: The cosmics filter is used in MJCalibration now
1243 independant of the pulser color (formaly it was used only for
1244 CT1-pulser data). The threshold of number of max empty pixels
1245 has been raised from 2% to 5% in MJCalibration. The maximum
1246 fraction of rejected event is 50% otherwise the calibration has
1247 failed. The filter now ignores unsuitable pixels.
1248 Setup the filter from callisto.rc using "ContCosmics"
1249 (see MFCosmics::ReadEnv)
1250
1251 - callisto: changed default for fgOffsetFromLogain back
1252 from -2.8 to -1.8 in digital filter.
1253
1254 - callisto: for the common extractors
1255 + MExtractFixedWindow
1256 * MExtractTimeAndChargeSlidingWindow
1257 * MExtractTimeAndChargeSpline
1258 * MExtractTimeAndChargeDigitalFilter
1259 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1260 and fResolutionPerPheLoGain
1261
1262 - callisto: Updated the hi-/lo-gain intercalibration constants
1263 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1264 hilocalib_df6.root
1265
1266 - callisto: The default lo-gain extraction window for the
1267 MExtractTimeAndChargeSlidingWindow extractor has been increased
1268 from 6 to 8 to take the stretch of the pusle into account
1269
1270 - callisto (!!!): fixed an important bug in the setting of the
1271 incoming pedestal pointer to the signal extractor extracting
1272 pedestals. This bug caused the pedestals not to be subtracted
1273 correctly in the calibration afterwards. The effect was about 10%
1274 too high conversion factors for the digital filter and the spline
1275 and more than 40% for the sliding window.
1276 The bug existed since end of February! (Markus G.)
1277
1278 - star: added muon support to star. A new tab "MHMuonPar" is
1279 displayed. The lower right plot is an estimate of the point spread
1280 function. A reference value is displayed. To get the real PSF
1281 you must compare with MC. The setup for the muon analysis
1282 is done in star.rc. More informations can be found in
1283 MHSingleMuon and MHCalibParCalc
1284
1285 - star: The weather data is now displayed in star
1286
1287 - star: MEventRateCalc handles the calculation of the event rate more
1288 accurate now in case of the start of a new run inside a sequence
1289
1290 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1291 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1292 changed only minimally
1293
1294 - ganymed: (MJCut and MJOptimize) now displayes the number of
1295 excess events versus size. The energy estimation is done in
1296 MJSpectrum (sponde)
1297
1298 - ganymed: got support for using other variables than Alpha, eg. Theta.
1299 Therefor you need a class deriving from MHAlpha which supports
1300 this variable (one is already existing: MHTheta, which is now the
1301 default in ganymed). It is setup through ganymed.rc
1302
1303 - added a full featured spectrum program (sponde) which reads
1304 ganymed output and monte carlos and compiles a spectrum
1305
1306
1307
1308 *** Version 0.9.1 (2005/04/14)
1309
1310 - Fix bug on the arrival time reconstruction when using Digital
1311 Filter (in some marginal cases (10%) times were reconstructed shifted
1312 by 0.2 slices)
1313
1314 - all executables now return 2 where in previous versions -1 has
1315 been returned (gave problems with shell-scripts)
1316
1317 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1318 also done with a intercalibration input file
1319
1320 - a bug in the time fine adjustment of the digital filter has been fixed
1321
1322 - a lot of small fixes to calling TPad::Divide with a margin==0
1323
1324 - MStatusDisplay now shows the memory usage
1325
1326 - added a memory leak statistic after the eventloop
1327
1328 - MHadronness replaced by MParameterD
1329
1330 - MEnergyEst replaced by MParameterD
1331
1332 - wobble mode can now be switched on from the data-set
1333
1334 - switched on bad pixel detection for a pedestal level
1335 which is more than 5 times the variance
1336
1337 - Fixed default paths to be correct for the new data center
1338
1339 - Fixed handling of drive data. The pointing position in now
1340 copied to MPointingPos inside star for real and MC events
1341
1342 - made sure, that the sequences in a dataset are sorted by
1343 their number to ensure the correct synchronization
1344
1345 - added all resource files necessary to handle spline extraction
1346 of signal for the late 2004 and the early 2005 data
1347
1348 - update the reference lines for the december data
1349
1350 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1351 This is important for the Dec. and Jan. data where the calibration
1352 pulse position changes much.
1353
1354 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1355 filter. This corrects only an defective extraction of the MC at
1356 low-gain signals lower than 90 phes.
1357
1358 - fixed some slowdown in calibrating data with interleaved events from
1359 Jan and Dec. As a workaround made the pretty palette the default.
1360 The inverse Deep Blue Sea has a bug which slows down long calibration
1361 runs a lot.
1362
1363 - implemented new values from new starguider report as defined
1364 in TDAS00-07 V7.1 (eg SkyBrighness)
1365
1366 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1367 in starguider report (If you merpp the same reports with this version
1368 you'll get the correct units (arcmin) but a different result
1369 than with old versions (wrong units))
1370
1371 - Now the status display can also write PNG, JPEG and XPM (other file
1372 formats are still unsupported by root)
1373
1374 - added a lot of scripts and macros in directory datacenter used
1375 for automatic processing
1376
1377
1378
1379 *** Version 0.9 (2005/03/23)
1380
1381 - Calibration is now done autmatically into photo-electrons like
1382 decided by the Collaboration Board
1383
1384 - Reference lines in the display can be read from resource file
1385
1386 - Interlaced calibration events can be handled by callisto
1387
1388 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1389 and applied in callisto.
1390
1391 - class MJCalibTest can be called by callisto
1392
1393 - callisto can now run with three data types: rawdata, rootdata, MC
1394
1395 - added two classes mreport/MReportStarguider.cc and
1396 mreport/MReportStarguider.h for implementing starguider-data
1397
1398 - the output of merpp-update now contains starguider information:
1399 MReportStarguider and MTimeStarguider
1400
1401 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1402 values were lower than they should. This was more visible for high
1403 energy (Size) events.
1404
1405 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1406
1407 - added a new loop to callisto to support the correct extraction of
1408 the pedestal and pedestal rms through the signal extractor
1409
1410 - added class to perform fourier tranformation of a hexagonal structure
1411 (MHexagonalFT)
1412
1413 - added class to perform fourier tranformation of a hexagonal structure
1414 in a tasklist (MHexagonalFTCalc) example: hft.C
1415
1416 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1417 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1418 small pixels, example: extendcam.C
1419
1420 - added possibility to write data to memory (TTree) using MWriteRootFile
1421
1422 - added possibility to read a TTree stored only in memory by MReadTree
1423
1424 - new classes to deal with the interleaved calibration events:
1425 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1426
1427 - implemented filters to callisto to skip calibration events
1428
1429 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1430 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1431 the slices by statistics
1432 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1433 signal extractor without randomization
1434 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1435 with the signal extractor with randomization (extraction window is
1436 randomly fixed)
1437 The three kind of pedestal is not yet implemented (for speed reasons) as
1438 long as nobody really needs it:
1439 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1440 extracted with the signal extractor with randomization
1441
1442 - callisto now finds the pulse position in the data automatically
1443
1444 - implemented data reduction in calibrated data by reducing the precision
1445 of the stored floating point values (pedestal, rms and signal) to
1446 roughly 0.5%
1447
1448 - fixed showplot to make file format conversion (eg. converting a
1449 status display stored in a root file into a postscript file) in
1450 batch mode possible:
1451 showplot -b --save-as-ps[=outfile.ps] infile.root
1452
1453 - Allow class names as part of filter rules, eg
1454 (MFSupercuts) && (MHillas.fSize>100)
1455
1456 - fixed a lot of stuff to allow all programs to process MonteCarlo
1457 camera files.
1458
1459 - enhanced possibility to debug reading of resource file
1460
1461 - MDataChain should handle priorities of operator more
1462 accurate now
1463
1464 - completely revised the container in which the signal is stored
1465 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1466 * the new implementation is faster and
1467 * needs less storage space
1468
1469 - FIRST version which can process Monte Carlos through the
1470 whole chain of programs (callisto, star, etc)
1471
1472 - implemented new image parameters for the border length of
1473 the shower image (MNewImagePar2)
1474
1475 - implemented wobble-mode in ganymed
1476
1477 - new class (MJOptimize) taking care of all optimization processes
1478
1479
1480
1481 *** Version 0.8.6 (2004/10/05)
1482
1483 - New combined signal and time extractor
1484 MExtractTimeAndChargeDigitalFilter
1485
1486 - The Report for the trigger section in the CC run summary has been
1487 updated, and now the IPRs (Individual Pixel Rates) are available.
1488
1489 - new macros for database interaction: filldotrun.C, filldotrbk.C
1490
1491 - added new program which can convert colored output which was redirected
1492 into a file back into colored text (for example to display it with
1493 more): showlog
1494
1495 - added new program to display an MStatusArray of plots (stored with
1496 MStatusDisplay) from a file: showplot
1497
1498 - Added support for Sequences (MSequence). Sequences are blocks of run
1499 files containing the same calibration and belonging to the same
1500 source
1501
1502 - Added a new task (MTaskEnv) which can be used in setup files to switch
1503 between different tasks (for example to choose a signal extractor)
1504
1505 - Implemented automatic file splitting in MWriteRootFile
1506
1507 - After image cleaning an island index is assigned to all used pixels.
1508 The index corresponds to the order of the islands in size.
1509
1510 - added a cleaning which takes signal height _and_ arrival time into
1511 account: probability cleaning (for more details see MImgCleanStd)
1512
1513 - added a cleaning which takes takes the absolute number of photons
1514 times the area ratio as cleaning level
1515 (for more details see MImgCleanStd)
1516
1517 - Changed calculation of image parameters such, that it can be done
1518 for all used pixels or the pixels with a defined island index only
1519
1520 - implemented new image parameters displaying the number of islands,
1521 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1522
1523 - event display in executable changed to support also calibrated files
1524 (done with MJCalibrateSignal)
1525
1526 - added program doing the calibration and the signal extraction
1527 and signal calibration: callisto Most part of the setup is done
1528 by a resource file: callisto.rc
1529
1530 - implemented support for pixels with negative IDs (Raw file format
1531 version 4)
1532
1533 - implemented an new option in merpp (--auto-time) to get the time
1534 range for cc and/or caco data from the run header of the raw data
1535
1536 - New star-program (star and MJStar). Taking calibrated data from
1537 callisto/MJCalibrateSignal as input. The setup is done through
1538 a resource file: star.rc
1539
1540 - Added possibility to setup the eventloop in the mars-executable
1541 Camera Display by a resource file: mars.rc
1542
1543 - The the mars-executable Camera Display can now also read
1544 calibrated data files written by callisto/MJCalibrateSignal
1545
1546 - Added a new class which can calculate the source position in
1547 the camera from a pointing model known to be correct and
1548 the pointing model used for observations (MSrcPosFromModel)
1549
1550 - added a new version of the class calculating the effective on-time
1551 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1552 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1553 MHTimeDiffTheta.
1554
1555 - added the possibility to count how often a signal is above (or
1556 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1557 can replace MHTriggerLvl0)
1558
1559 - added ore convinient ways to set the axis-titles of your histograms
1560 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1561 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1562
1563
1564
1565 *** Version 0.8.5 (2004/08/06)
1566
1567 - new Signal Extractors: MExtractFixedWindowSpline
1568 and MExtractAmplitudeSpline
1569
1570 - implementes interleave in merpp to be able to merpp parts of a file
1571
1572 - implemented force-functionality to merpp
1573
1574 - star display to display star catalogs (MAstroCatalog)
1575
1576 - star display to 'mirror' stars to the camera (MAstroCamera)
1577
1578 - implemented a new cleaning option which allows cleaning scaled with
1579 the real ratio of the rms depending on the pixel size, not only the
1580 square root of the pixelsize (MImgCleanStd, MCameraData)
1581
1582 - removed obsolete MBlind* classes
1583
1584 - Signal extractor taking the AB flag into account implemented (this makes
1585 an odd number of slices for signal extraction possible
1586 (MExtractSignalABcorr)
1587
1588 - implemented a class extracting the pedestal from the raw-data (events)
1589 itself using empty lo-gain (MpedCalcFromLoGain)
1590
1591 - Added mean values to MPedPhotCam
1592
1593 - Added Makefile for Darwin (this OS is NOT officially supported!)
1594
1595
1596
1597 *** Version 0.8.4 (2004/04/19)
1598
1599 - new fast arrival time extractor using cubic splines:
1600 MExtractTimeFastSpline
1601
1602 - implementes multi-argument support in MDataChain
1603 ("pow(a, b)")
1604
1605 - implemented double reference support in MDataChain
1606 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1607
1608 - added support in MF for expressiond like
1609 "MHillas.fWidth<2*<MHillas.fLength"
1610
1611 - MDataChain is now able to support variables like [0], [1], ...
1612 which can be used in fit functions as parameters. The interface
1613 is implemented through the new virtual function
1614 MParContainer::SetVariables
1615
1616 - added new class MArrivalTimeCam/MArrivalTimePix:
1617 Storage containers to hold the ArrivalTime of the camera/pixel
1618
1619 - added new classes for the calibration of relative arrival times:
1620 MCalibrationRelTimePix and MCalibrationRelTimeCam
1621
1622 - added new classes to extract the signal of the blind pixel and the
1623 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1624
1625 - added new classes for the bad-pixels treatment (MBadPixels*)
1626 which are more powerfull than the old ones (MBlindPixel*)
1627 and will replace them.
1628
1629 - added filter against cosmics: MFCosmics
1630
1631 - added new class MArrivalTimeCalc2:
1632 Calculates the arrival time as the signal weighted mean of the time
1633 slices in the maximum window
1634
1635 - added a new macro call pointspreadfucntion.C that fits with a 2D
1636 gaussian the DC spot for an star. It gives you the RMS of
1637 the PSF and the center of the star, very useful for misspointing
1638 studies.
1639
1640 - added support for multi-telescope camera files. Added classes
1641 MStereoCalc and MStereoPar, classes to calculate and store shower
1642 parameters calculated from the data of two telescopes, for the MC
1643 studies regarding the MAGIC clone.
1644
1645 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
1646 MC data calibrated in photons instead of ADC counts.
1647
1648 - added three macros to show the calibration and analysis chain of
1649 MC data. The macro starmc.C does both calibration and analysis, producing
1650 an output containing Hillas parameters for each event. The macro
1651 mccalibrate.C does just the calibration and writes out a file containing
1652 pixel information in photons instead of FADC data. The macro starmc2.C
1653 reads in such a file and produces an output with Hillas parameters.
1654
1655 - added MPedPhotCalc to compute pedestals in units of photons, see
1656 macro pedphotcalc.C
1657
1658 - added all class to perform the calibration, see macro calibration.C
1659
1660 - added class MFFT to perform Fast Fourier Transforms
1661
1662 - added class MSimulatedAnnealing to perform simulated annealing
1663 minimizations
1664
1665 - added new macro bootcampstandardanalysis.C which holds the skeleton
1666 of the analysis chain discussed in the december bootcamp.
1667
1668 - added support for DAQ raw data file format V2
1669
1670 - implemented an arbitrary time stamp for the events from raw-data
1671 files with file version<3. It is calculated from the run number,
1672 the date of start and the FADC clock tick from the first module
1673
1674 - implemented the correct decoding of the event time-stamp
1675 coming from the DAQ for raw-data files with file-version>2
1676
1677 - added a new classes storing the pedestals in units of photons:
1678 MPedPhotPix, MPedPhotCam
1679
1680 - added support for DC current files from the camera control
1681
1682 - added support for start- and stop-time when merpping report files
1683
1684 - added MReportCC storing the weather data from the CC-REPORT
1685
1686 - added class to fill trainings and test matrices (MTFillMatrix)
1687
1688 - added a filter performing a software trigger (MFSoftwareTrigger)
1689
1690 - Added classes to perform parts of the standard analysis (Jobs):
1691 + MJPedestals
1692 + MJCalibration
1693 + MJExtractSignal
1694 Note: All of them are preliminary!
1695
1696 - Added Iterator to iterate over files giving only the run-number
1697
1698 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
1699 the evolution of a sector vs time
1700
1701
1702
1703 *** Version 0.8.3 (2003/12/05)
1704
1705 - adapted Random Forest classes to allow the use with MC
1706 multi-telescope files which can be produced with the coming
1707 camera version 0.7.
1708
1709 - added classes to read and interprete central control report files
1710 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
1711
1712 - enhanced merpp (the executable) to support .raw and .rep files.
1713
1714 - added classes for light calibration (MCalibration* and
1715 MHCalibration*) by Markus Gaug. Further work has to be and will
1716 be done soon.
1717
1718 - Added a preliminary 'synchronizer' (MReadReports) which will
1719 replace MReadMarsFile as soon as it is finished.
1720
1721 - Added a tutorial macro demonstrating how report files are merpped
1722 and how they can be read from the root file in the correct order
1723 of time (readrep.C)
1724
1725 - Added a generalized histogram (similar to MH3) called MVsTime
1726 which allows to plot variables (or rules - MDataChain - of
1727 variables) vs time. For an example have a look at tempvstime.C.
1728
1729 - Changed the name of the event trees:
1730 + Events --> Events
1731 + PedEvents --> Pedestals
1732 + CalEvents --> Calibration
1733
1734 - changed name of MTime in the event trees from MRawEvtTime to MTime
1735
1736 - added displaying the sector indices to the mars event display
1737
1738 - Magic Online Analysis (MOnA) implemented in a first version
1739 (see mona.cc, MOnlineDump and MOnlineDisplay)
1740
1741 - added classes to calculate event rate
1742 (preliminary: MEventRateCalc, MEventRate)
1743
1744 - added new executable 'readdaq' to read *.raw files from the DAQ directly
1745
1746 - added classes dealing with the telescope pointing position (MPointing*)
1747
1748 - implemented the 'final' Mars time stamp based on some experiences with
1749 the new 'Synchonizer'
1750
1751
1752
1753 *** Version 0.8.2 (2003/11/10)
1754
1755 - accelerated standard analysis by a factor of 6-8 ...
1756 + doing precalculations in MGeomCam for the pixel area ratio
1757 + creating a look up table for the single pixels in MCerPhotEvt
1758
1759 - added task to calculates weights in case you want to 'change'
1760 the energy spectrum of a monte carlo file
1761 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
1762
1763 - added a new executable star which implements the
1764 star.C macro as precompiled executable. Currently a flexible
1765 setup is not possible, but a 'input card' setup will follow.
1766
1767 - Starting to implement Multi-Telescope-Support based on the
1768 upcomming camera version 0.7. The base for a general support
1769 is implemented and the star-functionality is proven to work.
1770
1771 - Replaced Event-Display in and Camera-Display in the Mars GUI
1772 executable by a more convinient display base on MStatusDisplay.
1773
1774 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
1775
1776
1777
1778 *** Version 0.8.1 (2003/10/20)
1779
1780 - added signal subtraction for pure on data by means of fitting
1781 the background in the off region or by performing a combined
1782 signal/background fit. Provides necessary histograms for
1783 obtaining energy spectra and a light curve.
1784
1785 - added classes to perform and study the selection of the
1786 2nd Level Trigger on MC data (example in triglvl2.C macro)
1787
1788 - added pedestal calculation
1789
1790 - implemented "democratic cleaning" (tail cut value proportional
1791 to pixel area) according to Wolfgang's suggestion.
1792
1793 - added Sigmabar treatment (calculation and basic histogramming)
1794
1795 - added basic routines to apply padding
1796
1797 - added first implementation of MARS-based source visibility plotter
1798 (needs to be linked against slalib, preliminary version)
1799
1800 - enhanced functionality of data chains: random numbers, conversion
1801 functions and access to MHMatrix objects
1802
1803 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
1804 numbers under certain circumstances (runs with 0 events included)
1805
1806 - fixed a bug in the general filter MF (didn't work on some systems
1807 at all)
1808
1809 - fixed a bug in chaining files, which caused the analysis to crash or
1810 ignore files
1811
1812 - implemented more geometry classes describing the parameters used
1813 to simulate the PMT camera
1814
1815 - added new Monte Carlo classes containing the setup of the different
1816 programs in the MC chain.
1817
1818 - added a (preliminary) general task to evaluate chi-square of a given
1819 parameter in an eventloop.
1820
1821 - first implementation of a container describing the observatory
1822 location (Long, Lat, etc)
1823
1824 - added Random Forest - method for g/h-separation
1825
1826 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
1827 (this means, that it is compiling, but not yet fully tested)
1828
1829 - added a new status display which can show the present status
1830 of histograms while an eventloop is running (MStatusDisplay,
1831 an example can be found at status.C)
1832
1833 - reorganized directories:
1834 classes describing the image --> mimage
1835 classes containing Monte Carlo Histograms --> mhistmc
1836 classes for Random Forest method --> mranforest
1837
1838 - added (event-)weights to fill histograms
1839
1840 - colors in logging output to screen
1841
1842 - changes to the Image Parameter declaration:
1843 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
1844 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
1845 + MHillasExt now derives from MParContainer instead of MHillas
1846 --> Files written with the old definition are more or less unreadable
1847
1848 - reading of reflector files
1849
1850 - display data from reflector files in the camera
1851
1852 - implemented currents (and display them in the camera)
1853
1854 - logarithmic scale in camera
1855
1856 - added class to iterate through directory contents (MDirIter)
1857
1858
1859
1860 *** Version 0.8 (2002/11/18)
1861
1862 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
1863
1864 - corrected 48(!) wrong entries in the Next Neighbor table of the
1865 Magic Camera (all in the inner part of the outer ring, mostly
1866 missing a single NN)
1867
1868 - Fixed a bug in the table describing the Next Neighbours of the
1869 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
1870 have any neighbour)
1871
1872 - changed trigrate.C: now it calculates the pure NSB triggers from
1873 a camera file (generated with no showers), so there is no need
1874 to introduce them by hand in the BgR array (for more details
1875 please ask Abelardo)
1876
1877 - added MHHadronness (and MHadronness) as a general facility to evaluate
1878 the quality of a gamma-hadron seperation method
1879
1880 - changed MWriteAsciiFile to accept rules (MDataChain)
1881
1882 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
1883 must be replaced by calles to MWriteAsciiFile::AddColumn and
1884 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
1885 changed.
1886
1887 - Implemented generalized event-matrices (one row per event)
1888 (MHMatrix)
1889
1890 - implemented the one dimensional composite probabilities
1891 (MHCompProb, MCompProbCalc, comprob.C)
1892
1893 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
1894 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
1895
1896 - Added a camera display displaying the pixel numbers to the
1897 event display gui.
1898
1899 - Added Monte Carlo Informations to event display gui
1900
1901 - Changed the camera display to display the pixel numbering
1902
1903 - Added three buttons to the camera display to change the palette
1904
1905 - Added the number of used and core pixels after image cleaning
1906 to MHillas
1907
1908 - Changed the algorithm used in MHillas according to TDAS 02-03
1909
1910 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
1911
1912 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
1913
1914 - Added fCosDeltaAlpha to MHillasSrc
1915
1916 - The numbers of photons used to calculate fConc and fConc1 in
1917 MHillasExt are now scaled with the pixel size, so that one get
1918 a four times smaller value for the bigger pixels in the outer ring.
1919
1920 - added new task to smooth the camera contents (MCameraSmooth)
1921
1922 - added possibility to use interpolated pixel values for blind pixels
1923 instead of removing it completely from the analysis
1924
1925 - Implemented the possibility to save the whole eventloop with
1926 its setup to a file. This information can be read and from
1927 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
1928 and MEvtLoop::MakeMacro. If you find something not working, please
1929 report - this stuff is still in a beta phase.
1930
1931 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
1932 file having crab starfield, but also for all following files - fixed
1933
1934 - MTaskList::PrintStatistics can now be instructud to print also the
1935 title, too: use PrintStatistics(0, kTRUE)
1936
1937 - Changed the image cleaning so that pixels with to many 'used'
1938 neighbors are left used (to get rid of 'holes' in events)
1939
1940 - Introduced more output to the camera displays
1941
1942 - Added an array of histograms (eg one hist per run), MHArray
1943
1944 - Added a _preliminary_ version of the reader for CT1 PreProc files
1945 (MCT1ReadPreProc)
1946
1947 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
1948 (thanks to Raquel)
1949
1950 - added the first energy estimator (MEnergyEstParam, estimate.C,
1951 estfit.C) using a parametrization
1952
1953 - Added some new Monte Carlo paremeter containers used to store
1954 setup information from the MC chain (MMcConfigRunHeader,
1955 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
1956
1957
1958
1959 *** Version 0.7 (2002/04/30)
1960
1961 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
1962 the pedestal mean value was saved incorrectly. For files from
1963 this versions we substract 0.5 from the pedestal mean.
1964 WARNING: This may effect your results, so don't wonder...
1965
1966 - First implementation of an algorithm using only triggered events
1967 for the collection area calculation
1968
1969 - Ascii Output can now also be used for parameter containers which
1970 doesn't overload MParCointainer::AsciiWrite
1971
1972 - The Ascii Output is now also capable of writing single data members
1973 of one container
1974
1975 - You are now able to change the order of the values written to the
1976 ascii file
1977
1978 - You can now specify a conversion factor for each data member written
1979 to an ascii file. This may be usefull to change the units of the
1980 data member (eg. degrees instead of millimeters in case of the
1981 hillas parameters)
1982
1983 - Replaced old MHillas by a new structure which allows you to extend
1984 the parameters stored in MHillas very easily:
1985 see MHillas and MHillasExt
1986
1987 - Added classes to handle source dependancy of image parameters:
1988 see MHillasSrc
1989
1990 - Added container (MBinning) to have a standard input for the binning
1991 in different histograms (eg. the Energy bins should be the same in
1992 all histograms)
1993
1994 - Changed Hillas histograms from mm to deg
1995
1996 - Added the flexible binning to the hillas histograms
1997
1998 - Added a filter for the alpha parameter (MFAlpha)
1999
2000 - It is now possible to write single data members of a class object to
2001 an output stream instead of the whole container only
2002
2003 - Added a generalized filter for a data member:
2004 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2005
2006 - Added a generalized Filter parser for more difficult filter rules
2007 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2008
2009 - Added new Monte Carlo histograms:
2010 MHMcEnergyImpact and MHMcEfficiency
2011
2012 - Added many new histograms needed for the flux calculation.
2013
2014 - Added a generalized histograms which can fill and show up to three
2015 data members in either a one-, two- or three-dimensional histogram, eg:
2016 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2017
2018 - Added:
2019 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2020 * calculation of <Theta> as a function of time (MHThetabarTime)
2021 they are needed in the flux calculation in
2022 order to select for a given bin in Theta (or time) the appropriate
2023 effective collection area, which is assumed to be given as a function
2024 of Theta and the true energy
2025
2026 - Added calculation of the migration matrix in the energy
2027 (MHMcEnergyMigration):
2028 the migration matrix describes the migration from the true (E_true)
2029 to the estimated energy (E_est); it is needed to determine the
2030 distribution of E_true from the measured distribution of E_est
2031 by unfolding
2032
2033 - changed the color palette in the camera display to DeapSea.
2034
2035
2036
2037 *** Version 0.6 (2002/01/15)
2038
2039 - Introduce the option of disable pixels (MBlindPixels and
2040 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2041 able to deal with Star Field NSB.
2042
2043 - Fixed a bug in the pedestals substraction
2044
2045 - Introduced verbosity levels
2046
2047 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2048
2049 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2050 work correctly (thanks to Abelardo)
2051
2052 - Introduced correct treatment of the diffuse Night Sky Background
2053 and NSB (MMcPedestalNSB)
2054
2055 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2056
2057 - Introduced MMcRunHeaders which contains monte carlo run informations
2058
2059 - Added a 'Print'-Task (MPrint) which calls the Print function
2060 of a parameter container for each event
2061
2062 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2063
2064 - changes to be more efficient with root 3.02/06
2065
2066 - root 3.02/06 fixes:
2067 + the memory leak when reading MRawEvtData
2068 + loosing more time than necessary to update the progress bar
2069
2070 - MWriteAsciiFile is now capable of writing more than one container
2071 in a line. For example: To be able to write Monte Carlo and
2072 Hillas values (energy and alpha) in one line.
2073
2074
2075
2076 *** Version 0.5 (2001/11/06)
2077
2078 - Added new GUI functionality (Analysis)
2079
2080 - Added a camera display to be able to display events in the camera
2081 together with the calculated hillas ellipse
2082
2083 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2084 object at any state of the analysis, so that the output are several
2085 states
2086
2087 - Fixed a bug in the collection area error calculation
2088 (Thanks to Ciro and Abelardo)
2089
2090 - Fixed a bug which causes merpp to crash in some environments
2091
2092 - Implemented auto enabling scheme for Branches to speed up reading
2093 a lot (see MReadTree and MTask)
2094
2095 - Fixed a bug in the Histogram classes which caused histograms to
2096 be written to a file by MWriteRootFile without request
2097
2098 - changed the object I/O from the old stylish root I/O to the new
2099 'auto evolution scheme' This was done only for classes which are not
2100 yet used in Monte Carlo files, so that these files are still readable.
2101
2102 - Added support for a progress bar in MEvtLoop and MReadTree
2103 (see the Analysis Window in Mars for an example)
2104
2105 - Fixed a bug in the package creation which disturbed the conversion
2106 between a mars version unpacked from a tar file and the repository.
2107
2108 - Changed the code to writer merpped (converted into root format)
2109 raw files, to get faster (around 10%)
2110
2111
2112
2113 *** Version 0.4 (2001/09/20)
2114
2115 - This release is made to compile on a root version >= 3.00
2116
2117 - Fixed a bug which causes MReadTree to read the first file only
2118
2119 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2120
2121 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2122
2123 - Added a task to write several container to a root file (MWriteRootFile)
2124
2125 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2126
2127 - Added calculation of the collection area (MMcCollectionAreaCalc)
2128
2129 - fixed some bugs in the Hillas calculation
2130
2131 - added filters to be able to control the task execution dependent on
2132 a parameter (for example: the number of level 1 triggers in a MC-file)
2133
2134
2135
2136 *** Version 0.3 (2001/04/23)
2137
2138 - Many demo macros added
2139
2140 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2141
2142 - Hillas Calculation added
2143
2144 - Standard image cleaning available
2145
2146 - MReadTree is now able to handle more than one file
2147 (Remark: of the same structure)
2148
2149 - Now we are able to display events in a first version of the
2150 Camera event display. To do this we must run the macro
2151 "macros/readCT1.C" to read data from CT1.
2152
2153
2154
2155 *** Version 0.2 (2001/01/24)
2156
2157 - First Implementation of a Gui to read the raw data. Start the
2158 gui with the command mars.
2159
2160
2161
2162 *** Version 0.1 (2000/12/20)
2163
2164 - First official release 0.1
2165
2166 - Changes:
2167
2168 + changed calling style of MRawPixelIterator from do...while to
2169 while-loop
Note: See TracBrowser for help on using the repository browser.