source: trunk/MagicSoft/Mars/NEWS@ 8672

Last change on this file since 8672 was 8671, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 104.5 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Now the output files (calib*.root, etc) also contain the
11 resource file (to check it open it in the TBrowser and choose Print()
12 from the context menu)
13
14 - general: Dataset files now allow to overwrite the default path
15 to search for sequence and data files. Note, that the program
16 option and individual resources will overwrite it. For example:
17 SequencePath: /magic/montecarlo/sequences
18 DataPath: /magic/montecarlo/star
19
20 - general: Fixed a problem with variables in MDataPhrase. It seems
21 that only optimdisp (didn't work) was effected.
22
23 - general: Some improvements to the optim and train processing. For
24 example the ststud window now got a proper title.
25
26 - general: The "Status Display: " was removed from the window title
27 within an Eventloop.
28
29 - merpp: Merpp can read file format version 9 now. Please realize
30 that for file format version 9 the extraction range is different
31 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
32 the first and last 15 slices have been removed from all MUX data.
33
34 - mars: Similar to writing movies you can now select events which
35 should be displayed in your display. Therefore add the following
36 lines to your mars.rc:
37 MFEvtNumber.FileName: ganymed00223552.root
38 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
39 The input file can be a ganymed-file after (ganymed*.root) or
40 before (ganymed*-summary.root) file. For example to select all events
41 from your on sample after cuts (excluding the ThetaSq cut) use
42 MFEvtNumber.Selector: DataType.fVal>0.5
43 To show all events from your on-sample after quality cuts
44 use the summary file instead.
45
46 - mars: new ways to call mars are implemented. Instead
47 of calling
48 mars filename.root
49 you can now also use
50 mars sequence.txt
51 or
52 mars sequence.txt inputpath
53 or replace sequence.txt by the sequence number if the default
54 sequence file should be used.
55
56 - mars: The default size has been increased
57
58 - mars: There are two new heckboxes which allow to switch off
59 the calculated image parameters
60
61 - callisto: was broken for MCs... fixed.
62
63 - callisto: improved calculation of spline coefficients a lot. This
64 leads to a further improvement of the event rate calibrating MUX
65 data of about 15% (175evt/s instead of 150evt/s)
66
67 - callisto: finally the raw data we read is now real 16bit (with
68 10bit precision) for MUX data and not a stripped 8bit number
69 anymore. Due to scaling of the numbers (without precision loss
70 into an [0-256[ range, the final numbers for pedestal, pedestalrms
71 and extacted signal don't change. However, at all places where
72 raw data is directly accessed (eg. saturation and variation
73 limits in the signal- and pedestal-extraction) the numbers
74 refer still to the data's 16bit range.
75
76 - callisto: The maximum arrival time difference used in the bad
77 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
78 for both, old FADC and MUX-FADC, data.
79
80 - callisto: Be aware that callisto is now calibrating the arrival time
81 in nanoseconds rather than time slices. Also all following tasks
82 have been changed to assume ns units now. If you star data
83 calibrated with an older version it might be necessary to adapt
84 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
85 to obtain optimal results. The plot in the PulsePos tab
86 will now be in ns, too. This might also mean that the Muon
87 analysis in star might not work as perfect as expected as long
88 as old files read in.
89
90 - star: For speed reasons events suitable for the muon analysis
91 are now also preselected by fConcCOG<0.1 which seems to be a very
92 good preselector for muons.
93
94 - star: is now calculating a new timing parameter the Slope along
95 the major and minor axis of the shower. Therefore a numerical
96 solution of a line-fit is used. To use MHillasExt.fSlopeLong
97 and MHillasExt.fSlopeTrans don't forget to multiply it with
98 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
99
100 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
101 have been removed from MNewImagePar. They have never been good for
102 anything.
103
104 - star: Implemented a new recursive algorithm which is supposed to be
105 faster. Also implemented new cleaning oiptions, which are:
106 + CleanLevel0:
107 The cleaning level above single core pixels can be kept
108 + KeepIsolatedPixels:
109 Define whether single core pixels should be kept
110 + TimeLevel1:
111 The coincidence window in nanoseconds to single used neighbors
112 + TimeLevel2:
113 The coincidence window in nanoseconds to two used neighbors
114 + PostCleanType:
115 MOde in which a time dependent post cleaning should be applied
116 0: No post cleaning
117 1: Require for each used pixels at least one used neighbor
118 within a time-window of CleanLevel1
119 2: Require for each used pixels at least two used neighbor
120 within a time-window of CleanLevel2
121 3: Require first two and second one used neighbor
122 within a time-window of CleanLevel1 and fCleanLevel2
123 respectively
124 + RecoverIsolatedPixels:
125 - recoveres isolated core pixels if they have a used neighbor
126
127 - mars/star: The new default cleaning is:
128 + CleanLevel1: 6.0
129 + CleanLevel2: 3.0
130 + CleanTime1: 1.75
131 + CleanTime2: 1.75
132 + PostCleanType: 3
133
134 - ganymed: The old hadronness and size cuts have gotten new indices
135 (10, 11). The old indices 8 and 9 now mean an additional condition
136 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
137 If you want to switch off this cut just move the line far away enough,
138 e.g. by setting c[9] to -500. Please update your ganymed.rc files
139 accordingly!
140 The unit of c[9] is deg. It is the dist at which your cut will
141 cross the slope==0. The unit of the slope is ns/deg. So if
142 you readin files calibrated with an older Mars-version you
143 have to adapt the default value for c[9] to the FADCs:
144 - Multiply by two for the MUX FADCs (run number > 200.000)
145 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
146 - Multiply by 42 for the meaning of life (run number = 200.000)
147
148 - ganymed: The old Cut0 is now called CutQ and is calculated before
149 the source position is caluclated. If you need a quality cut
150 including source dependant data (be very carefull with this!)
151 you have to use Cut0 instead.
152
153 - ganymed: now properly supports three off regions in wobble mode.
154 It will be the default from now on in ganymed_wobble.rc. To change
155 the number of off-regions use
156 NumOffSourcePositions: 1
157 in your ganymed.rc. Also by default no off-theta cut will be done
158 anymore so that you will get a background level higher than the
159 signal level in your ThetaSq plot for ThetaSq>0.2.
160 Due to this be carefull changing the scaling mode away from
161 "None". You will underestimate your signal if your scale interval
162 is not properly set.
163 (Rem: ThetaSqN is no longer needed)
164
165 - ganymed: is now storing the events of all (on- and off-)
166 source positions even in the case of more than one off-source
167 position. This should allow sponde to work properly and the
168 energy estimation is done correctly in all cases (without any
169 "nearest position" trick)
170
171 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
172 with a real pointing model for the starguider is done, calibrated
173 with more than thousand tpoints taken from this date on.
174
175 - ganymed: was broken for Wobble-MCs... fixed.
176
177 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
178 has changed. Note that your old ganymed.rc will be incompatible
179 with the new algorithms! Please check the ganymed.rc files and
180 the class description of MFMagicCuts for more information.
181 It is recommended at the moment to use identical Disp-Parametrizations
182 for on/off- and wobble-mode. If cuts are optimized only
183 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
184 should be optimized. All other values should be kept as they are.
185 If you want to do an anylsis without timing a parameters, you can
186 switch off the timing cuts by seeting parameter 7 to a very small
187 value (eg. -99). To remove the slope parameter from the disp
188 paremtrization set parameter 8 to 0.
189
190 - star/ganymed: The old spark-cuts have been replaced by new ones.
191 These new spark cuts have been cross checked with the sequences
192 84720 (before splitter), 101041 (after splitter) and 223539 (new
193 FADCs). In all cases they seperate pretty well, but of course not
194 perfect. Monte Carlos have suggested to tighten the cuts a little
195 bit further at low sizes. This has been done.
196
197 - ganymed: IMPORTANT - The spark cuts have been changed to match
198 all available data more or less well. This might mean that for
199 YOUR data there are still sparks visible.
200 Whenever you do an analysis you have to make sure that NO sparks
201 survive your cuts!
202
203 - ganymed: The distribution of observation time versus zenith
204 angle is now shown for off- AND on-data.
205
206 - optim, sponde: should now properly support three off-regions.
207 Just produce your ganymed summary files with three off-regions.
208 optim and sponde will automatically get all off events from
209 all off-regions from this file. Please do not forget to
210 set the scaling in optimwobble.C properly:
211 fit.SetScaleMode(MAlphaFitter::kNone);
212 fit.SetScaleUser(1./3);
213 it is not yet read in automatically (will follow soon).
214 In the case of fixed Scale you can also use
215 cuts.SetThetaCut(MFMagicCuts::kOn);
216 no off-cut needed.
217 Be carefull in case of three off-regions when switching on
218 scale mode. Make sure that the scale interval is set correctly.
219
220 - sponde: In the estimated energy versus monte carlo energy plot the
221 contents where exchanged.... fixed.
222
223
224
225 *** Version 1.2 (2007/05/14)
226
227 - database: The database now has two new values Unsuitable50 and
228 Unsuitable01. They express the number of pixels which are
229 unsuitable for more than 50%, respectively more than 1%, of
230 all calibrated event. It is a more accurate number than the
231 previously used numbers, because they only take the first
232 calibration (ignoring the interleaved calibrations) into account.
233
234 - database: The database now has two other new values UnsuitableMax and
235 DeadMax. They express the maximum number of pixels which were
236 unsuitable, respectively dead, during the sequence. Because
237 of high pedestal rms (cars passing) a few events with very high
238 numbers of unsuitable pixels can happen. Not to suffer from this
239 effect we don't take the highest 0.1% of the numbers into account.
240
241 - general: fixed a bug which caused callisto and star to stop working
242 properly because the callisto output was currupted
243
244 - general: a script called scripts/makemovie has been added which
245 simplified the process of producing several movies from a single
246 sequence with different setup.
247
248 - callisto: Some more code cleanup. Started to remove old obsolete
249 code from cvs.
250
251 - callisto: The extraction of the pedestal with the extractor was
252 not random. It seems that extracting at one position is still biased
253 (for example in the first or last slices we could still suffer from
254 switching noise) Now it is completely random.
255
256 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
257 pedestal files) individual pixels could be skipped due to high
258 variations. This was already the case for the pedestal extraction
259 from the lo-gains since the beginning and properly handled
260 there, but was introduced in the extraction from the pedestal files
261 a while ago. To calculate the average value it was still divided
262 by the number of events procesed not by the number of summands
263 really summed. This let to a pedestal which was a tiny amount too
264 small (for a few piels in the order of 0.1%). This led to an slightly
265 positive offset of the randomly extracted pedestal for a few pixels.
266 I doubt that this has a big effect on the result, because the effect
267 on the individual numbers is quite small. Due to this it is suggested
268 that you rerun your calibration to make sure you are without any
269 avoidable bias.
270
271 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
272 the median rms of the absolute arrival time and expressed in significance
273 levels. This replaces the old meaning of an abolute upper limit. An
274 absolute upper limit doesn't make much sense, because in our data
275 all arrival times are shifted at the same time (in fact it might be
276 a shift of the artificial trigger w.r.t. to the light flash).
277
278 - callisto: Added a new tab "BadPixTm" which shows the time evolution
279 of the number of unsuitable pixels over the whole sequence. This
280 is usefull mainly to judge if an intermediate calibration had
281 problems.
282
283 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
284 of the number of dead pixels over the whole sequence. Dead pixels
285 in this context are unmapped pixels, i.e. pixels which could not
286 be interpolated, and thus are ignored in the further analysis.
287
288 - callisto: It is now possible to use the position of the maximum
289 of the spline as arrival time instead of the leading edge even
290 when using the integral for the signal. Therefor set the extraction
291 type to kIntegralRel ("IntegralRelative") and the relative height
292 ("HeightTm") to -1:
293 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
294 MJPedestalC1.ExtractSignal.HeightTm: -1
295
296
297
298
299 *** Version 1.1 (2007/04/27)
300
301 - general: The new class MGeomCamDwarf contains the camera geometry
302 for our prefered Dwarf camera and can be used to create general
303 geometries of roundish or hexagonal cameras.
304
305 - mars: The default cleaning is now abolute 8.5/4.0.
306
307 - mars: The resource file mars.rc now contains examples for MUX data
308
309 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
310 data containing only 10-bit information is still cooked down to
311 8-bit, by cutting away the lowest 8-bit.
312
313 - merpp: When reading raw data the data is now stored in a single
314 array. The lo-gain array is obsolete. The interface stays the same.
315
316 - callisto: To process the new MUX data use the resource file
317 callisto_mux.rc
318
319 - callisto: The -root and -raw options to read merpped raw data have
320 been removed
321
322 - callisto: If the -mc option is given the sequence-name can now be
323 replaced by the MC sequence number
324
325 - callisto: If the sequence file contains "MonteCarlo: Yes" the
326 -mc option can now be omitted
327
328 - callisto: Started further simplification by removing obsolete
329 dependancies on MCalibIntensity*Cams.
330
331 - callisto: removed unsused intensity calibration from MJCalibration
332 for further simplification
333
334 - callisto: for simplification removed references to
335 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
336 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
337 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
338 (this should at minimum change nothing at all, and at maximum
339 improve thing if these containers where somewhere not handled
340 properly)
341
342 - callisto: Added the option to write an event movie. Please use
343 this option with care (huge files) but exessively to understand
344 our events. For further documentation please refer to the
345 IACT wiki
346 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
347
348 - callisto: Improved binning for the pulse position check histogram
349
350 - callisto: The code calculating the pulse position checknow takes
351 the pedestal into account
352
353 - callisto: The arrival time is now stored with full precision this
354 helps to get rid of artefacts in histograms. For the signal this
355 is not necessray because it is displayed in log-scale anyhow
356
357 - callisto: Fixed a problem with internal exclusions. Pixels which
358 have once been marked as unsuitable didn't get the necessary
359 histograms filled anymore to be rechecked with each interleaved
360 calibration.
361
362 - callisto: The relative arrival time resolution (the rms of the
363 relative arrival time offset) is now checked against its
364 median and the median deviation, instead of the average
365 plus an absolute offset.
366
367 - callisto: The relative arrival time offset is now calculated
368 w.r.t. its median not w.r.t. to an artificial reference pixel.
369
370 - callisto: The relative time calibration now marks pixels with
371 outlaying offset as unsuitable
372
373 - callisto: The interleaved relative time calibration has been switched
374 on. The advantage is that pixels which are marked as outliers
375 now can recover. An improvement over time is not expected, because
376 the relative time calibration seems stable.
377
378 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
379 option can now be omitted.
380
381 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
382 or the option "-mc" is specified as default the monte carlo datacenter
383 paths (/magic/montecarlo/...) are used if not overwritten in the
384 dataset file.
385
386 - ganymed: The output files now contain run- and event-number for all
387 events, accessible as RunNumber.fVal and EvtNumber.fVal
388
389 - ganymed: Added a plot showing the source position in the camera also
390 for wobble mode
391
392 - ganymed: In addition to the existing task which can be setup to
393 be executed after Cut1 a final task called "EstimateEnergy"
394 has been added, executed before writing the final output
395 (ganymed00000000.root). The task setup in all three cases
396 can be choosen individually. (For all three(!) cases you
397 can for example choose MRanForestCalc. For examples see all
398 sponde*.rc and all ganymed*rc)
399
400 - ganymed: If a container "MEstimatedEnergy" is found in the
401 parameter list (eg. because it was setup by MEstimateEnergy)
402 it will be written to the output file.
403
404
405
406 *** Version 1.0 (2007/02/16)
407
408 - database: Website to plot values from the database has been added.
409
410 - database: The rate of spark events as found by star is now kept
411 and the rate after cleaning is now with spark events subtracted
412
413 - general: The changes to the interpretation of phrases lead to
414 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
415
416 - general: Added example files how you can create your own calendar
417 (eg. as christmas present) with Mars. Just run
418 root macros/tutorials/calendar.C
419
420 - general: Added a possibility to display grouped data in the plotdb.C
421 macro (and similar macros). This allows to plot hourly, nightly,
422 weekly, monthly and yearly averages.
423 For more details see the plotall function of the macro
424
425 - general: fixed the error display of the camera display. It showed
426 wrong results.
427
428 - general: fixed a memory leak when reading many MStatusDisplays
429
430 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
431 between a spherical and a parabolic mirror
432
433 - callisto: We have a new pulse position check which takes the properties
434 of the extractor automatically into account. So no need to set
435 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
436 left is done. If possible the lo-gain extraction start and hi-gain
437 extraction end is changed accordingly. If no proper extraction range
438 can be set (hi-gain too much to the left) an error is raised.
439
440 - callisto: New swapped pixels have been found and corrected
441
442 - callisto: Redone the signal extraction this includes:
443 + Unified the algorithms to extract the pedestal for all pedestal
444 extractions done
445 + Unification of hi- and lo-gain into one array
446 + Unification of hi- and lo-gain extraction for Spline and
447 Digital Filter (means now exactly the same algorithm is used,
448 not a copy-and-pasted one)
449 + Store pedestal subtracted data in a common place
450 + Improved extraction algorithms. If the algorithms search a
451 maximum but don't find one they don't return the maximum anymore
452 + Improved the extraction such that a information for signal
453 and time which is consistent is returned
454 + replaced the numerical spline with a (not slower) analytical
455 solution
456 + Lowered the saturation limit from 250 to 245 to make sure that
457 we are far away in all pixels from problems with the clock-noise
458 + The start of the lo-gain extraction is calculated from the hi-gain
459 arrival time. In case of saturation an estimation is used.
460 + the hi-gain window was extended to slice 16. This allows extraction
461 of very late pulses in single pixels or of huge hadron showers.
462 + Now uses the lo-gain extraction range for pedestal extraction,
463 not the hi-gain range in the lo-gain
464
465 - callisto: New hi-/lo-gain calibration constants have been produced
466 for all periods from the statistic of the whole period. They are
467 now used automatically depending on the periods. The old constants
468 where deviation in avarega about 2%-3%. The constants are very
469 stable from period to period (<<1%) except for exchanged channels.
470 In a few cases the constants used so far were off by 1%-2% (maybe
471 temperature effects?)
472
473 - callisto: To gain obsolete space we do not write the
474 MPedestalFundamental anymore. Also calibration and bad pixel
475 treatment is not done for it anymore because it has never been used.
476
477 - callisto: Fixed a bug in the seuqence handling which caused the
478 light condition to be ignored
479
480 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
481 basically the same as "Cleaned" but the distribution devided into
482 the events fullfilling a spark cut or being rejected by it.
483 This cut can be changed from star.rc (see example inside) by
484 the "SparkCut" directive
485
486 - star: Star displays now the average individual pixel-rate (IPR) versus
487 time and the average discriminator threshold (DT) of all pixels.
488
489 - optim: fixed a problem with the optim-macros which was due to a bug
490 in the new phrase parsing
491
492 - ganymed: To get a nice FalseSource plot (instead of the all-information
493 debug plot displayed as a standard plot) use the context menu
494 somewhere between the two upper plots, click on "DrawNicePlot"
495 and enjoy the result. (It is the same context menu which contains
496 the other options)
497 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
498
499 - ganymed/optim/train: The cut program, trainings- and optimization
500 macros could run with less files found than expected from the
501 sequence-files. No the execution is stopped in this case.
502
503 - ganymed: now stores the dataset in the output file with all information
504 contained (as sequence number, sequence path, data path) so that the
505 used dataset file can be recreated complete from the output
506
507 - sponde: now also allows the uasge of random forest
508
509 - sponde: added a plot showing the cut efficiency
510
511 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
512 errors (eg. effecting the collection area) because the errors of the
513 two histograms were swapped in the calculation, which makes a difference
514 in the case the histograms contains weighted events. Aditionally the
515 totalarea was incorrectly taken into account, which results in too small
516 errors, which makes a difference at low statistics were the errors
517 or the collection area dominate.
518
519
520
521 *** Version 0.10.3 (2006/10/23)
522
523 - database: Implemented ObservationMode flag in websites.
524
525 - database: For sequences there is now also the stoptime available on the
526 websites.
527
528 - database: Removed ManuallyChanged flag from sequence-info websites,
529 as it is not needed anymore with the new sequence building algorithm.
530
531 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
532 Class for calculation of confidence intervals (upper limits).
533 Use model 3 or 4 for upper limit calculation for MAGIC observations.
534 Please read the class instruction of TRolke for more information.
535
536 - general: The programs now return 0xfe if the requested resource file
537 doesn't exist.
538
539 - general: Errors comming from root itself are now not output to
540 stderr anymore but to our default (colored) log-stream.
541
542 - general: Changed the interface to TFormula such that now everything
543 is parsed by TFormula, which should allow to use phrases even
544 without paranthesis correctly parsed.
545
546 - callisto: replaced the AdHoc number of effective integration slices
547 in the digital filter by an average of the correct number, averaged
548 over all possible set of weights. This also gives correct numbers
549 for the lo-gains which were totally wrong before.
550
551 - callisto: drastically reduced memory consumption by not storing
552 all intermediate calibration results in memory anymore (we might
553 write them into a file in the future)
554
555 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
556 debug plot displayed as a standard plot) use the context menu
557 somewhere between the two upper plots, click on "DrawNicePlot"
558 and enjoy the result. (It is the same context menu which contains
559 the "DrawAll" option)
560 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
561
562
563
564 *** Version 0.10.2 (2006/10/15)
565
566 - general: changed the building of the sequence files such, that
567 the source-/project name in case of wobble-sources is not the
568 source/project of the first data run anymore but the new generalized
569 wobble source/project
570
571 - general: Added some functions to MAstro to calculate sun and
572 moon properties
573
574 - general: Added two new macros (starvisday.C and starvisyear.C)
575 which allow to plot the visibility of several stars in one day
576 or of one star along one year
577
578
579
580 *** Version 0.10.1 (2006/10/11)
581
582 - general: HTML logging output was distorted... fixed.
583
584 - general: Changed the writing of the sequencefiles such that only
585 as many pedestal files as giving at least 1000 pedestal events which
586 are nearby the first calibration run are used as pedestal runs
587
588 - sponde: In the calculation of the collection area(s) and the
589 distribution for MOnte Carlo and estimated energy the error
590 calculation was wrong because root didn't take the errors
591 properly into account... fixed.
592
593
594
595 *** Version 0.10 (2006/10/10)
596
597 - general: all executables now check consistency of the root version
598 installed with the root version used for compilation. The return
599 code in this case is 255.
600
601 - general: The algorithm to build seqeunces has been redesigned
602 completly. It is now more flexible in terms of a resource file
603 resources/sequences.rc which can be used to partly overwrite
604 the default algorithm and defined the important part of the
605 algorithm. It also takes correctly into account several ways
606 of taking wobble-data. Currently the new algorithm doesn't take
607 the number of pedestal events anymore into account (so a sequence
608 could have much less than 1000 pedestal events and data runs are
609 no-more used instead)
610
611 - general: a lot of small changes to make the code compatible with
612 root 5.12/00 and gcc 4.1
613
614 - general: Fixed some warnings thrown if more warnings are switched
615 on in the compiler
616
617 - general: Added a function to MMath which returns the Median of
618 the distribution abs(y[i]-median) but at 68:32 division instead
619 of 50:50, which is somehow the median counterpart of the rms.
620
621 - general: MAstroCatalog allows now to read calatog files (as bsc5)
622 even if they are compressed with gzip (recommended compression
623 is with "-1")
624
625 - showplot:
626 + batch mode creation of image files now works with root 5.12/00
627 + added support for writing bmp (though it never produces
628 bmp which can be read by programs like xv or gimp)
629 + added support for xml
630 + added new option to start the display with a different size, by
631 --display-width=nnn or --display-height=nnn
632 + added options to define the canvas size when the display is started
633 --canvas-width=nnn or --canvas-height=nnn
634 the option can also be used for batch-mode conversion
635 + added an option which automatically fits the display size to the
636 desktop-size: --auto-size
637
638 - merpp: didn't recognize files with the extension .raw.gz - fixed.
639
640 - merpp: allow the reports to have 1000ms due to a bug in the camera
641 program.
642
643 - callisto: New swapped pixels have been found and corrected. For
644 details see MRawRunHeader::FixAssignment()
645
646 - callisto: Callisto now raises an error if one of the input files could
647 not be opened.
648
649 - callisto: In some rare cases it could happen that in the signal
650 extraction of the digital filter the extractor returned nonsense
651 results due a wrong initializion of a variable (this happens in
652 cases in which the extracted signal is exactly zero or the
653 digital filter couldn't slide because of a too small extraction
654 window, which could happen in the lo-gain extraction)
655
656 - callisto: The lo-gains have been marked as valid in some cases
657 when they got not extracted at all (deltsumlo=deltatimelo=0) because
658 the allowed extraction range (fLoGainLast-fLoGainFirst) was
659 smaller than the number of slices (fLoGainWindowSize) needed
660 by the lo-gain extractor
661
662 - callisto: Updated absolute calibration constants (muon calibration)
663
664 - callisto: fixed a bug which caused the hi-gain saturation not
665 to be handled properly in the spline (the position of the
666 saturation was calculated incorrectly)
667
668 - callisto: fixed a bug which gave weird results if hi- _and_
669 lo-gain could not be extracted properly. In some cases hi-
670 and lo-gain have not been extracted at all and the random result
671 got calibrated. In other cases the hi-gain was saturating and the
672 lo-gain has not been extracted. For this a completly arbitraty
673 scale factor was applied to the result from extracting the
674 charge of the saturating hi-gain.
675
676 - callisto: improves handling of extracted signal if lo- and/or
677 hi-gain could not be extracted properly. If no appropriate
678 calibration of either the signal or the arrival time is possible
679 the pixel is now markes as unsuitable instead of estimated.
680
681 - callisto: Fixed a problem in the spline extraction which gave
682 weird results if the signal was extracted from the first (and
683 highest) slice (as a workaround extraction from the first
684 slice has been forbidden)
685
686 - callisto: Fixed a bug regarding the use of the QE which doesn't
687 effect the result because the default is used anyhow.
688 (The bug was there since 14/07/2005)
689
690 - callisto: Changed the default for fgLoGainStartShift to -2.4
691
692 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
693 factors to be always 10 for all pixels as soon as the first
694 calibration update has happend.
695
696 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
697 was off by more than one slice (which gives wrong values for
698 pixels which have saturated the hi-gain) This was a problem
699 mainly for timing studies, not so much for the automatic standard
700 analysis. Also the values for the Spline have been changed slightly:
701 + Digital Filter from 1.70 to 0.95
702 + Spline from 1.39 to 1.30
703 The numbers were sorted out by an extensive test in the
704 test-database.
705
706 - callisto: Removed the tab showing the average calibrated arrival
707 time. It never gave useful information.
708
709 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
710 lo-gain pulse for data pulses if hi- and lo-gain have saturated
711 and both were extracted because the hi-gain was above the
712 LoGainSwitch.
713
714 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
715 lo-gain pulse position (after application of LoGainOffset, which
716 means in the ideal case it is 0) for data pulses if hi- and lo-gain
717 have saturated and both were extracted because the hi-gain was above
718 the LoGainSwitch.
719
720 - callisto: After extensive tests a new threshold level for determination
721 of the pulse position has been found at 50phe. This is due to the
722 fact that for lower pulses the arrival time changes its average
723 behaviour dramatically. It tends to the average of the extraction
724 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
725
726 - callisto: Added two more plots to the calibration part. The average
727 extracted signal and the average extracted arrival time as
728 extracted by the signal extractor (This can help debugging problems
729 because it doesn't involve a fit)
730
731 - star: changed the fit for the effective on time such that initial
732 values are calculated automatically now instead of using build
733 in values. This makes the fit more indepedant of the underlaying
734 rates. With a test of ~350 sequences in the test database it could
735 be shown that the new fit gives the same result +/-1sek.
736 The highest deviation was +5s the lowest -10s. You can now control
737 the bahaviour with two resource values:
738 MHEffectiveOnTime.FistBin: 3
739 MHEffectiveOnTime.NumEvents: 12000
740 Use FirstBin=1 and NumEvents=120 to fit the effective on time
741 from the resulting gamma candidates
742
743 - star: The Center histogram in MHHillas is now by default displayed
744 with the colz draw-option
745
746 - ganymed: now produces valid error codes if failed
747
748 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
749 with the option "hadronness" instead of "area" or "both" if
750 you want to use both cuts. The hadronness cut includes a fixed
751 cut in hadronness (index 8) and a fixed cut in size (index 9).
752
753 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
754 the M3Long of the anti source to be not properly evaluated
755 (actually is was evaluated as a unique random number) in case
756 of optimization with anti-theta cut switched on. This might have
757 lead to improper, but not necessarily wrong, optimization results.
758
759 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
760 how to use random forest
761
762 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
763 ganymed_onoff.rc. Seems to be unintentional that they were different.
764
765 - sponde: Since the introduction of the possibility to define a
766 normalization energy instead of using the integral the default
767 was not using the integral anymore but a normalization energy of
768 1GeV. It is now the integral again.
769
770 - sponde: Fixed a problem in the weighting which did not allow
771 a MC slope of -1.
772
773
774
775 *** Version 0.9.6 (2006/05/24)
776
777 - general: changed the binning of the azimuthal profile of the camera
778 such that it is aligned with the 60deg boundaries.
779
780 - merpp: better handling of problems with the TH, TD part of the
781 CC-REPORT for files older than 200507190 and 200412210
782 respectively
783
784 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
785
786 - merpp: implementd latest changes in starguider reports (sinc 9th May)
787
788 - callisto: if an arrival time is extracted outside the fadc range is
789 was set to the boundary before. Now a random number is assigned
790 instead to avoid unfortunate coincidences of arrival times just
791 by this arbitrary value.
792
793 - callisto: added a new option to callisto.rc which allows
794 to set the maximum arrival time difference allowed for the
795 badpixel algorithm to determin whether a pixels belongs to a shower:
796 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
797
798 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
799 to 0.9 as suggested by Stefan due to a recent study on the fraction
800 of pixels surviving the image cleaning
801
802 - callisto: switched off error in case of "pulse is too much to the left"
803
804 - callisto: The extraction window is not adapted anymore. This means that
805 the pulse is extracted from the full range. The draw-back is that the
806 background (pedestal) will become slightly higher. Switching on/off
807 the PulsePosCheck in the callisto.rc only effects filling the
808 histograms.
809 WARNING: If the pulse is too much to the left data is calibrated!
810 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
811 in the database to make sure that your data is valid!
812
813 - star: Show also the number of stars correlated correctly by the
814 starguider
815
816 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
817 than one off-source region in wobble-mode. To use it add the following to
818 your ganymed_wobble.rc:
819 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
820 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
821 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
822 + Cut1.ThetaCut: None
823 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
824
825 - ganymed: in the case the latest report is older than a default (currently
826 one minute) and the current report will be skip the starguider
827 correction and calibration will be reset. The maximum age can be
828 setup from ganymed.rc by (minutes):
829 MPointingDevCalc.MaxAge: 1.5
830
831 - ganymed: A first implementation showing all size-bins for the theta-sq
832 resp. alpha-plots in a single tab automatically
833
834
835
836 *** Version 0.9.5.1 (2006/05/05)
837
838 - general: Added a new option "zdiff" to the Makefile which runs
839 "cvs diff" as "make diff" would do, but with compression
840
841 - general: accelerated MTFillMatrix (used for eample in all training
842 and optimization macros) by skipping some obsolete calles in the
843 eventloop the first and second loop could be accelerated by ~20%
844
845 - general: Added a missing feature in the MFilterList class which
846 prevented MFEnergySlope from working correctly in trainenergy.C
847
848 - general: Accelerated the random forest training and usage a bit
849
850 - merpp: Adapted to new raw data file format version 6
851
852 - merpp: fixed a problem with reading the starguider reports
853 after 6.3.2006
854
855 - callisto: At some times six pixels had to be exchanged manually in the
856 data. If the pixels to be swaped are both not found, an error was raised
857 and calibration was stopped. Now it is assumed they are intentially not
858 mapped and the Error has been changed to a Warning.
859
860 - star: Added new image cleaning based on the arrival time of the shower.
861 The new cleaning can be accessed using the parameter "Time" instead of
862 the the old one (like "Absolute) in the star.rc-file.
863 Recommended parameters:
864 + MImgCleanStd.CleanLevel1: 8.2
865 + MImgCleanStd.CleanLevel2: 5
866 + MImgCleanStd.CleanRings: 2
867 + MImgCleanStd.KeepSinglePixels: No
868
869 - star: Simplified the calculation of the effective on time. By letting
870 the fit start in the third bin the result should become more stable.
871 The fit quality is now ignored for the theta-plot which is not used
872 in the analysis later. Still better pre-cut which, for example,
873 remove events triggered by car-light (rate changing on a short
874 time-scale) are missing.
875
876 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
877 for optimization (kWeakSource) which is suggested by the Berlin
878 people for weak sources.
879
880 - macros: plotdb.C:
881 + if no dataset and no time-interval is given only sequences with
882 an effective on-time above five minutes are plotted anymore
883 + added a new tab "RelTime" displaying the relative on-time
884 (effective on-time divided by the observation time)
885
886 - macros: optim*.C: by skipping some obsolete calles in the eventloop
887 the optimization became a lot faster
888
889 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
890 To display them just delete the pads displayed on top.
891
892 - ganymed: fixed a bug which could cause strange behaviour in wobble
893 mode if no starguider information was available due to an incorrect
894 initialization of the starguider calibration
895
896 - ganymed: The scale region in the False Source Plot (MHDisp) can now
897 be changed from within the plot. It can also be setup from the
898 resource file using:
899 + MHDisp.fScaleMin: 0.325
900 + MHDisp.fScaleMax: 0.475
901
902 - ganymed, showplot: Fixed a problem with the fit to the off-data
903 (HistOff) which could cause a time lag or an inifinite loop.
904 The bug did not effect the results at all.
905
906 - sponde: Added a new tab showing the effective collection area after
907 trigger (including the software trigger)
908
909 - sponde: MMcSpectrumWeight has a new option which allows to define
910 the scaling factor not by the integral of the events but at
911 a defined energy:
912 e.g. MMcSpectrumWeight.NormEnergy: 200
913
914 - MTFillMatrix, sponde: by skipping some obsolete calles in the
915 eventloops the loop could be accelerated by ~20%
916
917
918
919 *** Version 0.9.5 (2006/03/13)
920
921 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
922 and added the standard Disp-parametrization
923
924 - macros: added a new macro datacenter/macros/plotstat.C allowing
925 to plot statistics about the data processing
926
927 - macros: added a new macro to plot the muon correction coefficients
928 versus period (macros/plot/mucal.C)
929
930 - showplot: path inflation for ganymed files was broken
931
932 - callisto: Fixed an important bug. When the number of saturating pixels
933 were calculated the bad pixel information already available from the
934 calibration was ignored. This yields wrong values in case pixels
935 are broken and saturate all the time or randomly.
936
937 - callisto: Updated Muon calibration constants. Spline data now also uses
938 different values for different periods
939
940 - star: The time-evolution shown in the effective on-time plot now displays
941 the axis range (if there are no holes it should be similar to the
942 effective on-time)
943
944 - star: Added two new image parameters:
945 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
946 the three pixels next to the center of gravity and the size
947 + MNewImagePar.fConcCore: The ratio of the signals of all
948 pixels inside or touching the ellipse and the size
949
950 - ganymed: now stops in requested source isn't found in catalog file
951
952 - ganymed: Many improvements to the phi-plot in wobble mode:
953 + with a template the ideal background is displayed
954 + a possible camera inhomogeneity is taken into account
955 + the anti theta cut is better supported
956 + the phi cut is automatically calculated from the theta cut
957 See the examples in ganymed_wobble.rc for more details.
958
959 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
960 times the bin-width instead of the absolute energy
961
962 - ganymed: New cuts for on/off and wobble mode
963
964 - ganymed: The smearing of the False Source plot has been increased
965 to 0.06
966
967 - ganymed: The starguider calibration can now be changed from the
968 resource file.
969 See the examples in ganymed*.rc for more details.
970
971 - ganymed: added a new option for on-/off-observations
972 MJCut.RandomSourcePosition
973 If switched on the distribution of observation time of the source
974 position in the camera is calculated from the on-data and randomly
975 applied with this distrbution to the off-data.
976
977 - ganymed: by skipping some obsolete calles in the eventloop the
978 first and second loop could be accelerated by ~20%
979
980 - ganymed: The default in ganymed_onoff.rc is now to determin the source
981 position in the off-data randomly according to its distribution in the
982 on-data.
983
984
985
986 *** Version 0.9.4.3 (2006/02/13)
987
988 - general: Fixed a bug in most of the programs which prevented the
989 compile date in the startup message to be displayed
990
991 - general: Simplified program calls. The following abbreviations
992 are now possible:
993 showlog callisto 55599
994 showplot signal 55599
995 star 55599
996 callisto 55999
997 ganymed 2
998 In this cases the corrsponding root-, log-, sequence- or dataset-
999 filename is automatically compiled using the default datacenter
1000 paths ("/magic/*")
1001
1002 - general: Fixed a long outstanding bug which made axis tick marks
1003 disappear if MDataFormula was used (eg. abs(x))
1004
1005 - general: Updated MMath with new functions to calculate the results of
1006 a exponential, logarithmic and powerlaw fits analytically.
1007
1008 - general: Updated some macros with comments:
1009 + macros/optim/optimdisp.C
1010 + macros/optim/optimenergy.C
1011 + macros/optim/optimwobble.C:
1012
1013 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1014 files) now allows adding a pre-cut like in the optimization. E.g. this
1015 is useful to perform g/h-separation cuts before training the random
1016 forest.
1017
1018 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1019 correctly assigned in the raw data assignement table. A fix to correct
1020 the assignment tabel have been implemented.
1021
1022 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1023 by 90, 180 and 270 deg.
1024
1025 - general: the macro plotdb.C now allows to highlight sequences belonging
1026 to a datset. For more details see the descritions in the macro.
1027
1028 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1029 of the display, it gave wrong results espacially for big sizes.
1030 Now the embedded canvas should always have a ratio width/height=3/2.
1031 The "Size" options have been updated with values fitting the 3/2
1032 size ratio.
1033
1034 - RanForest:
1035 + Updated the random forest classes to support also the
1036 regression method implemented by Thomas H.
1037 + added new tutorial macro how to train the random forest
1038 for energy estimation (macros/optim/rfenergyest.C)
1039 + new classes to train the random forest (still in development)
1040 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1041 + new tutorial macros for random forest training in macros/train
1042 trainenergy.C, traindisp.C, trainseparation.C
1043
1044 - mars: now allows to setup a cut in the resource file mars.rc to choose
1045 the events to be displayed, eg:
1046 Cut.Condition: {0} && {1}
1047 Cut.0: MHillas.fSize>100
1048 Cut.1: MHillas.fSize<900
1049
1050 - merpp: Made aware of the new .rep format 200510250. This includes
1051 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1052 the discriminator thresholds (MCameraTD) and the disciminator
1053 delays (MCameraTD). All of them come with the CC report and are therefor
1054 written to the CC tree.
1055
1056 - callisto: fixed a bug in the calculation of the arrival times in
1057 the Digital Filter. They were all shifted by the same amount
1058 fHiGainFirst. This caused an offset in the order of the position of
1059 the left border of the extraction window in the times calculated
1060 from high-gain and from low-gain. The bug effected only the absolute
1061 arrival times. The bug was there since 30.1.2005.
1062
1063 - callisto: Changed the ExtractionWindow for the pulse position check
1064 such that the camera inhomogeneity becomes as less as possible and
1065 comparable to the pulso position check switched off. More details
1066 on the study will be given at our result web-page.
1067
1068 - ganymed: ganymed.rc, ganymed_onoff.rc:
1069 changed to new cuts trained with 1ES1218 and Crab-data
1070 for maximum sigma*log10(excess)
1071
1072 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1073 a new option was implemented to estimate Disp (CalcDisp)
1074
1075 - ganymed: Implemented two new options which allow
1076 to overwrite the default path to search for the sequence files
1077 --ins=/magic/sequences
1078 and where to search for the image data
1079 --ind=/magic/data/star
1080
1081 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1082 dx/dy from the resource file by
1083 MSrcPosCorrect.Dx
1084 MSrcPosCorrect.Dy
1085
1086 - ganymed: fixed reading the source catalog. Only as many chars
1087 as the requested source name had were compared (If a source
1088 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1089 were requested it could happen that the coordinates of
1090 "1ES1218" were read) The source coordinates are now printed
1091 in addition to its name to the logging output.
1092
1093 - ganymed: changed the background fit in the case of a ThetaSq function
1094 from a polynomial to a exponential, this should give a big improvement
1095 for on-only analysis'
1096
1097 - ganymed/sponde: Calculation of the error of single size-/energy-
1098 bins now uses Li/Ma (5) instead of LiMa (17)
1099
1100 - sponde: Added a plot E^2*dN/dE
1101
1102 - sponde: The energy estimator plot should now show values like
1103 they are commonly used.
1104
1105 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1106 (a powerlaw with cutoff didn't work before)
1107
1108
1109
1110 *** Version 0.9.4.2 (2005/10/01)
1111
1112 - general: added new tutorial macro macros/tutorials/threshold.C:
1113 how to calculate the threshold
1114
1115 - general: added a new game. Start it from the interpreter with
1116 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1117 and MagicReversi)
1118
1119 - general: neighbor pixels in MGeoms are now sorted clockwise
1120
1121 - merpp: made aware of new format 20050829-0
1122
1123 - callisto: New scale factors from muon analysis, stored in new
1124 resource file resources/calibration.rc
1125
1126 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1127 the eventloop if something went wrong. This is necessary for the
1128 automatic processing
1129
1130 - callisto: Implemented a new treatment for the time information
1131 developed by S.Ruegamer, this should give much better response than
1132 the old very primitive algorithm. This is especially important
1133 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1134 treatment was buggy! As neighbor pixels to interpolate the
1135 arrival times always the pixels 0 to 5 were taken)
1136
1137 - callisto: In addition to the new treatment of arrival times the
1138 decision of the treatment whether a pixel contains shower
1139 information or not is used to improve the signal interpolation
1140 further. Previously interpolated pixels showed a non-zero signal
1141 do the peak searching signal extractors. Having a signal pixel
1142 beside raised the signal above the cleaning level. Thus the
1143 pixel survived cleaning to often but with a too low mean signal.
1144 By replacing empty pixels with a gaus (mean and rms from the
1145 corresponding Area entries in MPedPhotCam) this effect can
1146 be supressed.
1147
1148 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1149 got lost when the events were stored by the calibration... fixed.
1150 (This was no problem for normal image cleaning because the pixel
1151 content was artificially set to 0 not surviving standard cleaning
1152 algorithm)
1153
1154 - callisto: Fixed a bug which caused the random and peak-search pedestal
1155 extracted with an extractor to be exchanged for the first (roughly)
1156 500 events (*Extractor and *ExtractorRndm).
1157 (They were simply exchanged in callisto.cc) This bug might have been
1158 introduced in Mars 0.9.4 when the order of calculation of the two
1159 types of pedestal in callisto got exchanged. The bug only effects
1160 the first seconds of data of each sequence.
1161
1162 - star: Taking the arrival time of Muons into account the calculation
1163 of the parameters could be made independant of the noise
1164 (pedestal rms). The dependance was due to the bias of the peak search
1165 extractor. Now only a ZA dependamcy is left which is not yet fully
1166 understood.
1167
1168 - ganymed: The sequences were still not sorted correctly in any case,
1169 because they were sorted by the full qualified path name. Now they
1170 are sorted by their sequence number.
1171
1172 - ganymed: new values for the spark-event-cut
1173
1174 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1175
1176
1177
1178 *** Version 0.9.4.1 (2005/08/18)
1179
1180 - callisto: fixed some problems with the calibration in case of
1181 inteleaved events. Therefor the final and some intermediate
1182 fits are skipped which would take place on partly filled #
1183 histograms and gave wrong results or failed completely.
1184
1185 - callisto: If the intermediate finalization of the histograms
1186 calculating the mean charge of the calibration signal fails
1187 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1188
1189 - ganymed: Fixed some bugs which caused problems in On-only mode.
1190 Still the false source plot doesn't give reasonable results.
1191
1192
1193
1194 *** Version 0.9.4 (2005/08/05)
1195
1196 - general: Fixed the ZA binning. It did not correctly fit the
1197 MC binning
1198
1199 - general: Added a class to correct for the missfocussing in
1200 April (MSrcPosCorrect)
1201
1202 - general: Random Forest energy estimator should now work properly
1203
1204 - general: MHCamera now displays the profiles in deg instead of mm
1205
1206 - general: MH::SetPalette offers a lot of new palettes
1207
1208 - general: MHillas - the case of CorrXY==0 is now handled properly
1209
1210 - general: implemented the possibility to change the line and
1211 marker style of a sky-grid drawn by MAstroCatalog
1212
1213 - general: Runs in sequences and datasets are now automatically
1214 ordered (it is assumed that the order of their filenames correctly
1215 represents the order of observations) to ensure correct reading
1216 of the subsystem data
1217
1218 - general: Runs cannot be added to a sequence twice anymore. Also
1219 Sequences cannot be added twice anymore to a dataset.
1220
1221 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1222 It gave wrong results by 1./2pi
1223
1224 - showplot: got a new option to start a root interpreter, too
1225
1226 - mars: now displays a rough estimate of Disp and the third moment
1227
1228 - mars: now displays the event time MTime if available
1229
1230 - mars: show muon parameters graphically
1231
1232 - mars: now the file to open can be given as commandline
1233 argument
1234
1235 - merpp: Added support for new arehucas version >= 200507190
1236 implementing values for three temperature sensors in the
1237 counting house (MCameraAUX) and the name of the HV settings file
1238 (MCameraHV).
1239
1240 - merrp: Also fixed some problems with wrong versions numbers stated
1241 by arehucas and implemented some fixed for old versions (<200407070)
1242
1243 - callisto: MCalibrationHiLoCam can now be printed from its context
1244 menu, eg in the TBrowser
1245
1246 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1247 - 1.39 (MExtractTimeAndChargeSpline)
1248 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1249 This is important mainly for timing studies.
1250
1251 - callisto: Changed limits in MHCalibrationChargeCalc from
1252 - -100.125 to -98 (fgChargeHiGainFirst)
1253 - 1899.875 to 1902. (fgChargeHiGainLast)
1254 - -100.25 to -99 (fgChargeLoGainFirst)
1255 - 899.75 to 901. (fgChargeLoGainLast)
1256 Introduced new limits:
1257 - fgNumLoGainBlackoutLimit: 0.05
1258 - fgLoGainBlackoutLimit: 3.5
1259 - fgLoGainPickupLimit: 3.5
1260
1261 - callisto: The handling of automatic weights for the digital filter
1262 has been improved. There are now new calibration weights special
1263 for Monte Carlo calibrations.
1264
1265 - callisto: Updated Muon scale with latest results (1% difference
1266 for most data, 5% for Mar/Apr'05)
1267
1268 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1269 was saturated and the blackout-events in the low-gain exceed the
1270 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1271 This excludes those pixels which have a saturating high-gain
1272 channel, but the low-gain switch does not switch often enough
1273 to make the distribution reliable.
1274
1275 - callisto: fix a bug counting the number of saturated events. Up to now,
1276 the number of saturated slices was counted (which is one for a not too
1277 high number), but for some (pathological) pixels, many more slices
1278 saturated and produced wrong limits.
1279
1280 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1281 + MCalibrationRelTimeCam.CheckFitResults: Yes
1282 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1283 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1284 + MCalibrationRelTimeCam.CheckOscillations: Yes
1285
1286 - callisto: introduce max. number of events for intercalibration,
1287 the rest gets skipped. Default: 4096
1288 The calibration causes too many un-reliable pixels if more
1289 than about 5000 events are treated (@500 Hz) because of the
1290 mode hopping of the VCSels. However, in the past, some
1291 calibration runs have been taken (erroneously) with more
1292 than 5000 events, especially the intensity scans where
1293 a good precision is needed.
1294
1295 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1296 photo-electrons for the spline extractor by 1-2% (correctly).
1297
1298 - callisto: The intercalibration is now done using a full f-factor
1299 method instead of a simple update. This makes things slower but
1300 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1301 changes.
1302
1303 - callisto: MPedestalY3 now uses the same extraction range as the data
1304 as calculated by MPedestalY2
1305
1306 - callisto: A check of the fraction of allowed unsuitable (10%) and
1307 unreliable (30%) pixels has been addded when the conversion is
1308 calculated from interleaved events
1309
1310 - star: fixed a bug which caused MEffectiveOnTime containers not to
1311 be written. In the worst case they were skipped almost all, in the
1312 best case they were all ok. It depends on how often the new value
1313 was assigned just with an event which was skipped later by another
1314 task
1315
1316 - star: new histograms MHPointing and MHRate
1317
1318 - star: New tab (Currents) displaying the time evolution of the mean
1319 DC currents
1320
1321 - star: New tab (MeanRms) displaying the time volution of the mean
1322 Pedestal Rms
1323
1324 - star: Output now contains MReportStarguider
1325
1326 - star: Improved muon analysis. Due to the absense of a constant
1327 for the gaus fit for arc width and the fact that the arcwidth
1328 plot was a histogram instead of a profile the resulting psf
1329 became pedestal rms dependant
1330
1331 - ganymed: added new plot (MHPhi) for wobble mode as described in
1332 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1333
1334 - ganymed: corrects now (correctly?) for the misspointing in
1335 May/April 05
1336
1337 - ganymed: Two new default templates for ganymed.rc are avilable:
1338 ganymed_onoff.rc and ganymed_wobble.rc
1339
1340 - ganymed: The first version of MFMagicCuts has been released
1341
1342 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1343
1344 - ganymed, sponde: There are two new options to determin the number
1345 of bins for the signal region (NumBinsSignal) and the number of
1346 total bins (NumBinsTotal) in the MHThetaSq histogram
1347
1348 - ganymed: optimized palettes for MHDisp
1349
1350 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1351 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1352 sqrt(2) to large
1353
1354 - ganymed: The false source plot (MHDisp) is now based on Disp
1355 and a background model determined in the first loop is
1356 subtracted
1357
1358 - ganymed: MFMagicCuts are now available in the cvs. The correct
1359 solution for the disp ambiguity problem is now calculated using
1360 the third moment. The third moment cut therefor is skipped.
1361
1362 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1363 already determined by the third moment along the major axis and
1364 so its actual sign is aligned along the major axis of the shower.
1365
1366 - ganymed: If starguider data is available it is taken into account
1367 when calculating the source position. This is especially important
1368 for wobble data at high zenith angles and culmination data.
1369
1370 - ganymed: If available the starguider data is taken into account as
1371 good as it is possible without a starguider calibration. To switch
1372 it off add
1373 MPointingDevCalc.MaxAbsDev: -1
1374 to your ganymed.rc
1375
1376 - sponde: the zenith angle distribution is now weighted instead of
1377 choosen by default. This gurantees higher statistics in the highest
1378 and lowest energy bins. To switch this behaviour off use...
1379
1380 - sponde: now automatically displays the energy threshold
1381
1382
1383
1384 *** Version 0.9.3 (2005/06/03)
1385
1386 - general: MMcEvt now derived from MMcEvtBasic which should
1387 have no influence on compatibility with older camera files
1388
1389 - general: Implemented a new option to MReadReports which allows
1390 to force reading of the first event of some trees (eg. Drive-tree)
1391 before any other tree.
1392
1393 - general: Made a fix to MPointingPosCalc which assumes that the
1394 run-type is real-data if Process is called before ReInit, such
1395 that also the very first Drive-events in a run are treated
1396 correctly.
1397
1398 - shoplot now displays the filename in the title bar of the window
1399
1400 - merpp: new options: --auto-time-start --auto-time-stop which
1401 allow to cut updating with slow-control at the start- or
1402 (previousle --auto-time only allowed: and) stop-time of
1403 the run stored in the runheader.
1404
1405 - callisto: changed default of fgFallTimeHiGain in
1406 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1407 already set as default in callisto_Dec04Jan05.rc
1408
1409 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1410 now changes the filename for new weights automatically for
1411 cosmics, MC and for different calibration colors.
1412
1413 - callisto: a problem with the order of some code cause the
1414 name of the weights file in MPedestalY2 to be ignored.
1415 Wrongly the calibration_UV weights were used instead
1416 of the cosmics weights set in callisto.rc.
1417
1418 - callisto: should allow ct1 pulser data when the color is
1419 explicitly set also for pretty new runs
1420
1421 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1422 to introduce an additional scale factor (should be around 1)
1423 to adapt for slight deviations in different extractors from
1424 the MC calibration. For MC calibrations the scale factor
1425 is fixed to 1
1426
1427 - callisto: MFCosmics should handle very high signals a bit
1428 more accurate now
1429
1430 - callisto: when calculating the mean pedestal rms for different
1431 pixel sizes or sectors also kUnsuitableEvt is now taken into
1432 account - not only kUnsuitableRun
1433
1434 - callisto: '-raw' option is now the default
1435
1436 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1437 This has the advantage that mean values in the calibration (eg
1438 arrival times) are calculated more accuratly.
1439
1440 - callisto: In the resource file callisto_Dec04Jan05.rc
1441 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1442
1443 - callisto: new Hi-/Lo-Gain intercalibration constants
1444 hilocalib_sp1.root and hilocalib_sp1_mc.root
1445
1446 - callisto: changed default for MJPedestalY2.MaxEvents
1447 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1448
1449 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1450 has changed from 9.0 to 6.0. This is necessary to exclude two very
1451 ringing pixels in September which - when kept - destroy the image
1452 cleaning around them (Markus G.)
1453
1454 - callisto: (!) The Muon analysis of all data taken so far has
1455 suggested that different extractors give slightly different
1456 absolute results after calibration, due to there different
1457 handling of the calibration- and cosmics pulse shape. Although
1458 the over all calibration seems to be a bit to pesimistic (or
1459 the MC seems to be a little bit - 3-5% - too much attenuated).
1460 There for correction factors have been introduced which correct
1461 the calibration constants by
1462 0.956937799 for Digital Filter (callisto.rc)
1463 and
1464 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1465 calibration. The main advantage is, that both data types can
1466 be easily analysed together and compared to the same MC sample.
1467 The factors are choosen such, that the reference is now a
1468 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1469
1470 - star: fixed a bug which caused the first bin of the histograms
1471 vs time to disapear in PostProcess. This gave wrong results
1472 on the screen. The output and all following programs not
1473 directly accessing the histograms haven't been affected
1474
1475 - star, ganymed: Made sure that always the first Drive-tree event
1476 is read and Processed before the first data event was read.
1477
1478 - ganymed: implemented the possibility to replace the standard
1479 false source plot with a different one. For example: If
1480 you want to use a Disp based FS plot use the resource:
1481 NameHistFS: MHDisp
1482 For details about the requirements of these plots look
1483 at the corresponding classes
1484
1485 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1486 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1487 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1488 case MAlphaFitter is setup correctly. For On-Only optimization
1489 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1490 RunOn() instead of Run(). For energy estimation MJOptimize
1491 has been replaced by MJOptimizeEnergy
1492
1493 - sponde: The input MC spectrum can now be weighted to fake a
1494 different spectrum. This is done via MMcSpectrumWeight. For
1495 more details see the class description and sponde.rc
1496
1497 - sponde: The paremeter comparsion plots are not scaled by
1498 their entries anymore. Instead the MC plot is scaled by using
1499 the result spectrum of the analysis. If the input MC spectrum
1500 and the result spectrum has different slopes the absolut
1501 normalization is normally wrong.
1502
1503
1504
1505 *** Version 0.9.2 (2005/05/20)
1506
1507 - general: Changed the default paths for calibrated data and image
1508 files. (The implemented access to these files doesn't yet exist)
1509
1510 - general: support for MRunIter has been removed from the job classes
1511 (use the setter functions of MSeqeunce instead)
1512
1513 - general: ProcessFile has been renamed to Process in all job classes,
1514 because ProcessFile is missleading
1515
1516 - general: The storage of the palette in MHCamera is now possible
1517
1518 - general: new bits describing unsuitable and unreliable pixels have
1519 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1520 kDeadPedestalRms, kFluctuatingArrivalTimes
1521
1522 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1523 versions newer than V200404070
1524
1525 - general: support for cc file versions newer than V200504130. Added
1526 support for active loads (MCameraActiveLoad) and central pixel
1527 (MCameraCentralPixel)
1528
1529 - general: added new histograms for image parameters versus size
1530 (MHVsSize)
1531
1532 - general: The eventloop now automatically calls PrintStatistics
1533
1534 - Status Display: Improved support for printing:
1535 + A default can now be set in .rootrc (for more details see
1536 MStatusDisplay::PrintPS)
1537 + A print dialog is opened so that printer and command line
1538 can be canged
1539
1540 - showlog: improved such that it handles different verbosity levels
1541 more accurate now. This mean you can suppress output when
1542 using showlog.
1543
1544 - showplot: improved
1545 + The new graphics formats have been implemented
1546 (pdf, svg, png, jpg and xpm)
1547 + Implemented an interface for printing. Because you can change
1548 the printing command from the command line you can use all
1549 the nice postscript tool. To print a booklet for example call:
1550 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1551 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1552 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1553
1554 - callisto: fixed a bug in the recognition of the calibration bit
1555 pattern. Concerns only intensity calibration. (The strength of the
1556 intensity has been updated in some cases)
1557
1558 - callisto: add a filter against PIN Diode events when running over
1559 calibration runs since some of the recent calibration runs have
1560 been taken with Pin Diode.
1561
1562 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1563 39943, 44833 in the calibration (MCalibColorSet)
1564
1565 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1566 been set to 1e-18 in callisto_Dec04_Jan05.rc
1567
1568 - callisto: in callisto_Dec04Jan05.rc: set value for
1569 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1570 statistics for the calculation of the mean pulse time
1571 of the cosmisc
1572
1573 - callisto: the charge limit in the calibration has been raised
1574 from 2.5 to 4.5
1575
1576 - callisto: new setup read from callisto.rc
1577 + MCalibCalcFromPast.fNumEventsDump
1578 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1579 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1580
1581 - callisto: MExtractTimeAndChargeSpline extractor:
1582 + The integration ranges were shifted by 0.2 FADC slices to the right.
1583 + unreliable handling of floating point values caused different
1584 results on different platform or with different compiler options:
1585 The new algorithm is numerically exact and more accurate because
1586 it doesn't calculate the integration position by multiple times
1587 adding the step-size (which results in numerical uncertanties
1588 exspecially if multiplied with large numbers)
1589 + A lot of fixes have been introduced which effects integrating the
1590 spline at the edges of the valid range. In this case any memory
1591 was randomly accessed. This behaviour can be tested replacing
1592 all MArrayF by TArrayF which perform a range check (but of course
1593 they are a lot slower)
1594 ! No result obtained with the Spline before can be trusted! Due to
1595 random memory access it might by completely random!
1596
1597 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1598 + extraction range in the high gain to 4.
1599 + weights file to cosmics_weights46.dat
1600
1601 - callisto:
1602 + introduce the check for fluctuating arrival times.
1603 + set charge limit to from 2.5 to 4.5
1604 + introduce asymmetric exclusion due to "deviating number of phes":
1605 Default: -9.0 +4.5
1606 + make deviating number of phes unsuitable (see David's findings).
1607
1608 - callisto: fixed the display of unsuitable pixels. The old change
1609 to a real profile in MHCamera broke it.
1610
1611 - callisto: The cosmics filter is used in MJCalibration now
1612 independant of the pulser color (formaly it was used only for
1613 CT1-pulser data). The threshold of number of max empty pixels
1614 has been raised from 2% to 5% in MJCalibration. The maximum
1615 fraction of rejected event is 50% otherwise the calibration has
1616 failed. The filter now ignores unsuitable pixels.
1617 Setup the filter from callisto.rc using "ContCosmics"
1618 (see MFCosmics::ReadEnv)
1619
1620 - callisto: changed default for fgOffsetFromLogain back
1621 from -2.8 to -1.8 in digital filter.
1622
1623 - callisto: for the common extractors
1624 + MExtractFixedWindow
1625 * MExtractTimeAndChargeSlidingWindow
1626 * MExtractTimeAndChargeSpline
1627 * MExtractTimeAndChargeDigitalFilter
1628 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1629 and fResolutionPerPheLoGain
1630
1631 - callisto: Updated the hi-/lo-gain intercalibration constants
1632 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1633 hilocalib_df6.root
1634
1635 - callisto: The default lo-gain extraction window for the
1636 MExtractTimeAndChargeSlidingWindow extractor has been increased
1637 from 6 to 8 to take the stretch of the pusle into account
1638
1639 - callisto (!!!): fixed an important bug in the setting of the
1640 incoming pedestal pointer to the signal extractor extracting
1641 pedestals. This bug caused the pedestals not to be subtracted
1642 correctly in the calibration afterwards. The effect was about 10%
1643 too high conversion factors for the digital filter and the spline
1644 and more than 40% for the sliding window.
1645 The bug existed since end of February! (Markus G.)
1646
1647 - star: added muon support to star. A new tab "MHMuonPar" is
1648 displayed. The lower right plot is an estimate of the point spread
1649 function. A reference value is displayed. To get the real PSF
1650 you must compare with MC. The setup for the muon analysis
1651 is done in star.rc. More informations can be found in
1652 MHSingleMuon and MHCalibParCalc
1653
1654 - star: The weather data is now displayed in star
1655
1656 - star: MEventRateCalc handles the calculation of the event rate more
1657 accurate now in case of the start of a new run inside a sequence
1658
1659 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1660 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1661 changed only minimally
1662
1663 - ganymed: (MJCut and MJOptimize) now displayes the number of
1664 excess events versus size. The energy estimation is done in
1665 MJSpectrum (sponde)
1666
1667 - ganymed: got support for using other variables than Alpha, eg. Theta.
1668 Therefor you need a class deriving from MHAlpha which supports
1669 this variable (one is already existing: MHTheta, which is now the
1670 default in ganymed). It is setup through ganymed.rc
1671
1672 - added a full featured spectrum program (sponde) which reads
1673 ganymed output and monte carlos and compiles a spectrum
1674
1675
1676
1677 *** Version 0.9.1 (2005/04/14)
1678
1679 - Fix bug on the arrival time reconstruction when using Digital
1680 Filter (in some marginal cases (10%) times were reconstructed shifted
1681 by 0.2 slices)
1682
1683 - all executables now return 2 where in previous versions -1 has
1684 been returned (gave problems with shell-scripts)
1685
1686 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1687 also done with a intercalibration input file
1688
1689 - a bug in the time fine adjustment of the digital filter has been fixed
1690
1691 - a lot of small fixes to calling TPad::Divide with a margin==0
1692
1693 - MStatusDisplay now shows the memory usage
1694
1695 - added a memory leak statistic after the eventloop
1696
1697 - MHadronness replaced by MParameterD
1698
1699 - MEnergyEst replaced by MParameterD
1700
1701 - wobble mode can now be switched on from the data-set
1702
1703 - switched on bad pixel detection for a pedestal level
1704 which is more than 5 times the variance
1705
1706 - Fixed default paths to be correct for the new data center
1707
1708 - Fixed handling of drive data. The pointing position in now
1709 copied to MPointingPos inside star for real and MC events
1710
1711 - made sure, that the sequences in a dataset are sorted by
1712 their number to ensure the correct synchronization
1713
1714 - added all resource files necessary to handle spline extraction
1715 of signal for the late 2004 and the early 2005 data
1716
1717 - update the reference lines for the december data
1718
1719 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1720 This is important for the Dec. and Jan. data where the calibration
1721 pulse position changes much.
1722
1723 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1724 filter. This corrects only an defective extraction of the MC at
1725 low-gain signals lower than 90 phes.
1726
1727 - fixed some slowdown in calibrating data with interleaved events from
1728 Jan and Dec. As a workaround made the pretty palette the default.
1729 The inverse Deep Blue Sea has a bug which slows down long calibration
1730 runs a lot.
1731
1732 - implemented new values from new starguider report as defined
1733 in TDAS00-07 V7.1 (eg SkyBrighness)
1734
1735 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1736 in starguider report (If you merpp the same reports with this version
1737 you'll get the correct units (arcmin) but a different result
1738 than with old versions (wrong units))
1739
1740 - Now the status display can also write PNG, JPEG and XPM (other file
1741 formats are still unsupported by root)
1742
1743 - added a lot of scripts and macros in directory datacenter used
1744 for automatic processing
1745
1746
1747
1748 *** Version 0.9 (2005/03/23)
1749
1750 - Calibration is now done autmatically into photo-electrons like
1751 decided by the Collaboration Board
1752
1753 - Reference lines in the display can be read from resource file
1754
1755 - Interlaced calibration events can be handled by callisto
1756
1757 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1758 and applied in callisto.
1759
1760 - class MJCalibTest can be called by callisto
1761
1762 - callisto can now run with three data types: rawdata, rootdata, MC
1763
1764 - added two classes mreport/MReportStarguider.cc and
1765 mreport/MReportStarguider.h for implementing starguider-data
1766
1767 - the output of merpp-update now contains starguider information:
1768 MReportStarguider and MTimeStarguider
1769
1770 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1771 values were lower than they should. This was more visible for high
1772 energy (Size) events.
1773
1774 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1775
1776 - added a new loop to callisto to support the correct extraction of
1777 the pedestal and pedestal rms through the signal extractor
1778
1779 - added class to perform fourier tranformation of a hexagonal structure
1780 (MHexagonalFT)
1781
1782 - added class to perform fourier tranformation of a hexagonal structure
1783 in a tasklist (MHexagonalFTCalc) example: hft.C
1784
1785 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1786 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1787 small pixels, example: extendcam.C
1788
1789 - added possibility to write data to memory (TTree) using MWriteRootFile
1790
1791 - added possibility to read a TTree stored only in memory by MReadTree
1792
1793 - new classes to deal with the interleaved calibration events:
1794 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1795
1796 - implemented filters to callisto to skip calibration events
1797
1798 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1799 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1800 the slices by statistics
1801 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1802 signal extractor without randomization
1803 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1804 with the signal extractor with randomization (extraction window is
1805 randomly fixed)
1806 The three kind of pedestal is not yet implemented (for speed reasons) as
1807 long as nobody really needs it:
1808 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1809 extracted with the signal extractor with randomization
1810
1811 - callisto now finds the pulse position in the data automatically
1812
1813 - implemented data reduction in calibrated data by reducing the precision
1814 of the stored floating point values (pedestal, rms and signal) to
1815 roughly 0.5%
1816
1817 - fixed showplot to make file format conversion (eg. converting a
1818 status display stored in a root file into a postscript file) in
1819 batch mode possible:
1820 showplot -b --save-as-ps[=outfile.ps] infile.root
1821
1822 - Allow class names as part of filter rules, eg
1823 (MFSupercuts) && (MHillas.fSize>100)
1824
1825 - fixed a lot of stuff to allow all programs to process MonteCarlo
1826 camera files.
1827
1828 - enhanced possibility to debug reading of resource file
1829
1830 - MDataChain should handle priorities of operator more
1831 accurate now
1832
1833 - completely revised the container in which the signal is stored
1834 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1835 * the new implementation is faster and
1836 * needs less storage space
1837
1838 - FIRST version which can process Monte Carlos through the
1839 whole chain of programs (callisto, star, etc)
1840
1841 - implemented new image parameters for the border length of
1842 the shower image (MNewImagePar2)
1843
1844 - implemented wobble-mode in ganymed
1845
1846 - new class (MJOptimize) taking care of all optimization processes
1847
1848
1849
1850 *** Version 0.8.6 (2004/10/05)
1851
1852 - New combined signal and time extractor
1853 MExtractTimeAndChargeDigitalFilter
1854
1855 - The Report for the trigger section in the CC run summary has been
1856 updated, and now the IPRs (Individual Pixel Rates) are available.
1857
1858 - new macros for database interaction: filldotrun.C, filldotrbk.C
1859
1860 - added new program which can convert colored output which was redirected
1861 into a file back into colored text (for example to display it with
1862 more): showlog
1863
1864 - added new program to display an MStatusArray of plots (stored with
1865 MStatusDisplay) from a file: showplot
1866
1867 - Added support for Sequences (MSequence). Sequences are blocks of run
1868 files containing the same calibration and belonging to the same
1869 source
1870
1871 - Added a new task (MTaskEnv) which can be used in setup files to switch
1872 between different tasks (for example to choose a signal extractor)
1873
1874 - Implemented automatic file splitting in MWriteRootFile
1875
1876 - After image cleaning an island index is assigned to all used pixels.
1877 The index corresponds to the order of the islands in size.
1878
1879 - added a cleaning which takes signal height _and_ arrival time into
1880 account: probability cleaning (for more details see MImgCleanStd)
1881
1882 - added a cleaning which takes takes the absolute number of photons
1883 times the area ratio as cleaning level
1884 (for more details see MImgCleanStd)
1885
1886 - Changed calculation of image parameters such, that it can be done
1887 for all used pixels or the pixels with a defined island index only
1888
1889 - implemented new image parameters displaying the number of islands,
1890 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1891
1892 - event display in executable changed to support also calibrated files
1893 (done with MJCalibrateSignal)
1894
1895 - added program doing the calibration and the signal extraction
1896 and signal calibration: callisto Most part of the setup is done
1897 by a resource file: callisto.rc
1898
1899 - implemented support for pixels with negative IDs (Raw file format
1900 version 4)
1901
1902 - implemented an new option in merpp (--auto-time) to get the time
1903 range for cc and/or caco data from the run header of the raw data
1904
1905 - New star-program (star and MJStar). Taking calibrated data from
1906 callisto/MJCalibrateSignal as input. The setup is done through
1907 a resource file: star.rc
1908
1909 - Added possibility to setup the eventloop in the mars-executable
1910 Camera Display by a resource file: mars.rc
1911
1912 - The the mars-executable Camera Display can now also read
1913 calibrated data files written by callisto/MJCalibrateSignal
1914
1915 - Added a new class which can calculate the source position in
1916 the camera from a pointing model known to be correct and
1917 the pointing model used for observations (MSrcPosFromModel)
1918
1919 - added a new version of the class calculating the effective on-time
1920 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1921 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1922 MHTimeDiffTheta.
1923
1924 - added the possibility to count how often a signal is above (or
1925 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1926 can replace MHTriggerLvl0)
1927
1928 - added ore convinient ways to set the axis-titles of your histograms
1929 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1930 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1931
1932
1933
1934 *** Version 0.8.5 (2004/08/06)
1935
1936 - new Signal Extractors: MExtractFixedWindowSpline
1937 and MExtractAmplitudeSpline
1938
1939 - implementes interleave in merpp to be able to merpp parts of a file
1940
1941 - implemented force-functionality to merpp
1942
1943 - star display to display star catalogs (MAstroCatalog)
1944
1945 - star display to 'mirror' stars to the camera (MAstroCamera)
1946
1947 - implemented a new cleaning option which allows cleaning scaled with
1948 the real ratio of the rms depending on the pixel size, not only the
1949 square root of the pixelsize (MImgCleanStd, MCameraData)
1950
1951 - removed obsolete MBlind* classes
1952
1953 - Signal extractor taking the AB flag into account implemented (this makes
1954 an odd number of slices for signal extraction possible
1955 (MExtractSignalABcorr)
1956
1957 - implemented a class extracting the pedestal from the raw-data (events)
1958 itself using empty lo-gain (MpedCalcFromLoGain)
1959
1960 - Added mean values to MPedPhotCam
1961
1962 - Added Makefile for Darwin (this OS is NOT officially supported!)
1963
1964
1965
1966 *** Version 0.8.4 (2004/04/19)
1967
1968 - new fast arrival time extractor using cubic splines:
1969 MExtractTimeFastSpline
1970
1971 - implementes multi-argument support in MDataChain
1972 ("pow(a, b)")
1973
1974 - implemented double reference support in MDataChain
1975 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
1976
1977 - added support in MF for expressiond like
1978 "MHillas.fWidth<2*<MHillas.fLength"
1979
1980 - MDataChain is now able to support variables like [0], [1], ...
1981 which can be used in fit functions as parameters. The interface
1982 is implemented through the new virtual function
1983 MParContainer::SetVariables
1984
1985 - added new class MArrivalTimeCam/MArrivalTimePix:
1986 Storage containers to hold the ArrivalTime of the camera/pixel
1987
1988 - added new classes for the calibration of relative arrival times:
1989 MCalibrationRelTimePix and MCalibrationRelTimeCam
1990
1991 - added new classes to extract the signal of the blind pixel and the
1992 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
1993
1994 - added new classes for the bad-pixels treatment (MBadPixels*)
1995 which are more powerfull than the old ones (MBlindPixel*)
1996 and will replace them.
1997
1998 - added filter against cosmics: MFCosmics
1999
2000 - added new class MArrivalTimeCalc2:
2001 Calculates the arrival time as the signal weighted mean of the time
2002 slices in the maximum window
2003
2004 - added a new macro call pointspreadfucntion.C that fits with a 2D
2005 gaussian the DC spot for an star. It gives you the RMS of
2006 the PSF and the center of the star, very useful for misspointing
2007 studies.
2008
2009 - added support for multi-telescope camera files. Added classes
2010 MStereoCalc and MStereoPar, classes to calculate and store shower
2011 parameters calculated from the data of two telescopes, for the MC
2012 studies regarding the MAGIC clone.
2013
2014 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2015 MC data calibrated in photons instead of ADC counts.
2016
2017 - added three macros to show the calibration and analysis chain of
2018 MC data. The macro starmc.C does both calibration and analysis, producing
2019 an output containing Hillas parameters for each event. The macro
2020 mccalibrate.C does just the calibration and writes out a file containing
2021 pixel information in photons instead of FADC data. The macro starmc2.C
2022 reads in such a file and produces an output with Hillas parameters.
2023
2024 - added MPedPhotCalc to compute pedestals in units of photons, see
2025 macro pedphotcalc.C
2026
2027 - added all class to perform the calibration, see macro calibration.C
2028
2029 - added class MFFT to perform Fast Fourier Transforms
2030
2031 - added class MSimulatedAnnealing to perform simulated annealing
2032 minimizations
2033
2034 - added new macro bootcampstandardanalysis.C which holds the skeleton
2035 of the analysis chain discussed in the december bootcamp.
2036
2037 - added support for DAQ raw data file format V2
2038
2039 - implemented an arbitrary time stamp for the events from raw-data
2040 files with file version<3. It is calculated from the run number,
2041 the date of start and the FADC clock tick from the first module
2042
2043 - implemented the correct decoding of the event time-stamp
2044 coming from the DAQ for raw-data files with file-version>2
2045
2046 - added a new classes storing the pedestals in units of photons:
2047 MPedPhotPix, MPedPhotCam
2048
2049 - added support for DC current files from the camera control
2050
2051 - added support for start- and stop-time when merpping report files
2052
2053 - added MReportCC storing the weather data from the CC-REPORT
2054
2055 - added class to fill trainings and test matrices (MTFillMatrix)
2056
2057 - added a filter performing a software trigger (MFSoftwareTrigger)
2058
2059 - Added classes to perform parts of the standard analysis (Jobs):
2060 + MJPedestals
2061 + MJCalibration
2062 + MJExtractSignal
2063 Note: All of them are preliminary!
2064
2065 - Added Iterator to iterate over files giving only the run-number
2066
2067 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2068 the evolution of a sector vs time
2069
2070
2071
2072 *** Version 0.8.3 (2003/12/05)
2073
2074 - adapted Random Forest classes to allow the use with MC
2075 multi-telescope files which can be produced with the coming
2076 camera version 0.7.
2077
2078 - added classes to read and interprete central control report files
2079 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2080
2081 - enhanced merpp (the executable) to support .raw and .rep files.
2082
2083 - added classes for light calibration (MCalibration* and
2084 MHCalibration*) by Markus Gaug. Further work has to be and will
2085 be done soon.
2086
2087 - Added a preliminary 'synchronizer' (MReadReports) which will
2088 replace MReadMarsFile as soon as it is finished.
2089
2090 - Added a tutorial macro demonstrating how report files are merpped
2091 and how they can be read from the root file in the correct order
2092 of time (readrep.C)
2093
2094 - Added a generalized histogram (similar to MH3) called MVsTime
2095 which allows to plot variables (or rules - MDataChain - of
2096 variables) vs time. For an example have a look at tempvstime.C.
2097
2098 - Changed the name of the event trees:
2099 + Events --> Events
2100 + PedEvents --> Pedestals
2101 + CalEvents --> Calibration
2102
2103 - changed name of MTime in the event trees from MRawEvtTime to MTime
2104
2105 - added displaying the sector indices to the mars event display
2106
2107 - Magic Online Analysis (MOnA) implemented in a first version
2108 (see mona.cc, MOnlineDump and MOnlineDisplay)
2109
2110 - added classes to calculate event rate
2111 (preliminary: MEventRateCalc, MEventRate)
2112
2113 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2114
2115 - added classes dealing with the telescope pointing position (MPointing*)
2116
2117 - implemented the 'final' Mars time stamp based on some experiences with
2118 the new 'Synchonizer'
2119
2120
2121
2122 *** Version 0.8.2 (2003/11/10)
2123
2124 - accelerated standard analysis by a factor of 6-8 ...
2125 + doing precalculations in MGeomCam for the pixel area ratio
2126 + creating a look up table for the single pixels in MCerPhotEvt
2127
2128 - added task to calculates weights in case you want to 'change'
2129 the energy spectrum of a monte carlo file
2130 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2131
2132 - added a new executable star which implements the
2133 star.C macro as precompiled executable. Currently a flexible
2134 setup is not possible, but a 'input card' setup will follow.
2135
2136 - Starting to implement Multi-Telescope-Support based on the
2137 upcomming camera version 0.7. The base for a general support
2138 is implemented and the star-functionality is proven to work.
2139
2140 - Replaced Event-Display in and Camera-Display in the Mars GUI
2141 executable by a more convinient display base on MStatusDisplay.
2142
2143 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2144
2145
2146
2147 *** Version 0.8.1 (2003/10/20)
2148
2149 - added signal subtraction for pure on data by means of fitting
2150 the background in the off region or by performing a combined
2151 signal/background fit. Provides necessary histograms for
2152 obtaining energy spectra and a light curve.
2153
2154 - added classes to perform and study the selection of the
2155 2nd Level Trigger on MC data (example in triglvl2.C macro)
2156
2157 - added pedestal calculation
2158
2159 - implemented "democratic cleaning" (tail cut value proportional
2160 to pixel area) according to Wolfgang's suggestion.
2161
2162 - added Sigmabar treatment (calculation and basic histogramming)
2163
2164 - added basic routines to apply padding
2165
2166 - added first implementation of MARS-based source visibility plotter
2167 (needs to be linked against slalib, preliminary version)
2168
2169 - enhanced functionality of data chains: random numbers, conversion
2170 functions and access to MHMatrix objects
2171
2172 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2173 numbers under certain circumstances (runs with 0 events included)
2174
2175 - fixed a bug in the general filter MF (didn't work on some systems
2176 at all)
2177
2178 - fixed a bug in chaining files, which caused the analysis to crash or
2179 ignore files
2180
2181 - implemented more geometry classes describing the parameters used
2182 to simulate the PMT camera
2183
2184 - added new Monte Carlo classes containing the setup of the different
2185 programs in the MC chain.
2186
2187 - added a (preliminary) general task to evaluate chi-square of a given
2188 parameter in an eventloop.
2189
2190 - first implementation of a container describing the observatory
2191 location (Long, Lat, etc)
2192
2193 - added Random Forest - method for g/h-separation
2194
2195 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2196 (this means, that it is compiling, but not yet fully tested)
2197
2198 - added a new status display which can show the present status
2199 of histograms while an eventloop is running (MStatusDisplay,
2200 an example can be found at status.C)
2201
2202 - reorganized directories:
2203 classes describing the image --> mimage
2204 classes containing Monte Carlo Histograms --> mhistmc
2205 classes for Random Forest method --> mranforest
2206
2207 - added (event-)weights to fill histograms
2208
2209 - colors in logging output to screen
2210
2211 - changes to the Image Parameter declaration:
2212 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2213 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2214 + MHillasExt now derives from MParContainer instead of MHillas
2215 --> Files written with the old definition are more or less unreadable
2216
2217 - reading of reflector files
2218
2219 - display data from reflector files in the camera
2220
2221 - implemented currents (and display them in the camera)
2222
2223 - logarithmic scale in camera
2224
2225 - added class to iterate through directory contents (MDirIter)
2226
2227
2228
2229 *** Version 0.8 (2002/11/18)
2230
2231 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2232
2233 - corrected 48(!) wrong entries in the Next Neighbor table of the
2234 Magic Camera (all in the inner part of the outer ring, mostly
2235 missing a single NN)
2236
2237 - Fixed a bug in the table describing the Next Neighbours of the
2238 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2239 have any neighbour)
2240
2241 - changed trigrate.C: now it calculates the pure NSB triggers from
2242 a camera file (generated with no showers), so there is no need
2243 to introduce them by hand in the BgR array (for more details
2244 please ask Abelardo)
2245
2246 - added MHHadronness (and MHadronness) as a general facility to evaluate
2247 the quality of a gamma-hadron seperation method
2248
2249 - changed MWriteAsciiFile to accept rules (MDataChain)
2250
2251 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2252 must be replaced by calles to MWriteAsciiFile::AddColumn and
2253 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2254 changed.
2255
2256 - Implemented generalized event-matrices (one row per event)
2257 (MHMatrix)
2258
2259 - implemented the one dimensional composite probabilities
2260 (MHCompProb, MCompProbCalc, comprob.C)
2261
2262 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2263 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2264
2265 - Added a camera display displaying the pixel numbers to the
2266 event display gui.
2267
2268 - Added Monte Carlo Informations to event display gui
2269
2270 - Changed the camera display to display the pixel numbering
2271
2272 - Added three buttons to the camera display to change the palette
2273
2274 - Added the number of used and core pixels after image cleaning
2275 to MHillas
2276
2277 - Changed the algorithm used in MHillas according to TDAS 02-03
2278
2279 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2280
2281 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2282
2283 - Added fCosDeltaAlpha to MHillasSrc
2284
2285 - The numbers of photons used to calculate fConc and fConc1 in
2286 MHillasExt are now scaled with the pixel size, so that one get
2287 a four times smaller value for the bigger pixels in the outer ring.
2288
2289 - added new task to smooth the camera contents (MCameraSmooth)
2290
2291 - added possibility to use interpolated pixel values for blind pixels
2292 instead of removing it completely from the analysis
2293
2294 - Implemented the possibility to save the whole eventloop with
2295 its setup to a file. This information can be read and from
2296 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2297 and MEvtLoop::MakeMacro. If you find something not working, please
2298 report - this stuff is still in a beta phase.
2299
2300 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2301 file having crab starfield, but also for all following files - fixed
2302
2303 - MTaskList::PrintStatistics can now be instructud to print also the
2304 title, too: use PrintStatistics(0, kTRUE)
2305
2306 - Changed the image cleaning so that pixels with to many 'used'
2307 neighbors are left used (to get rid of 'holes' in events)
2308
2309 - Introduced more output to the camera displays
2310
2311 - Added an array of histograms (eg one hist per run), MHArray
2312
2313 - Added a _preliminary_ version of the reader for CT1 PreProc files
2314 (MCT1ReadPreProc)
2315
2316 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2317 (thanks to Raquel)
2318
2319 - added the first energy estimator (MEnergyEstParam, estimate.C,
2320 estfit.C) using a parametrization
2321
2322 - Added some new Monte Carlo paremeter containers used to store
2323 setup information from the MC chain (MMcConfigRunHeader,
2324 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2325
2326
2327
2328 *** Version 0.7 (2002/04/30)
2329
2330 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2331 the pedestal mean value was saved incorrectly. For files from
2332 this versions we substract 0.5 from the pedestal mean.
2333 WARNING: This may effect your results, so don't wonder...
2334
2335 - First implementation of an algorithm using only triggered events
2336 for the collection area calculation
2337
2338 - Ascii Output can now also be used for parameter containers which
2339 doesn't overload MParCointainer::AsciiWrite
2340
2341 - The Ascii Output is now also capable of writing single data members
2342 of one container
2343
2344 - You are now able to change the order of the values written to the
2345 ascii file
2346
2347 - You can now specify a conversion factor for each data member written
2348 to an ascii file. This may be usefull to change the units of the
2349 data member (eg. degrees instead of millimeters in case of the
2350 hillas parameters)
2351
2352 - Replaced old MHillas by a new structure which allows you to extend
2353 the parameters stored in MHillas very easily:
2354 see MHillas and MHillasExt
2355
2356 - Added classes to handle source dependancy of image parameters:
2357 see MHillasSrc
2358
2359 - Added container (MBinning) to have a standard input for the binning
2360 in different histograms (eg. the Energy bins should be the same in
2361 all histograms)
2362
2363 - Changed Hillas histograms from mm to deg
2364
2365 - Added the flexible binning to the hillas histograms
2366
2367 - Added a filter for the alpha parameter (MFAlpha)
2368
2369 - It is now possible to write single data members of a class object to
2370 an output stream instead of the whole container only
2371
2372 - Added a generalized filter for a data member:
2373 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2374
2375 - Added a generalized Filter parser for more difficult filter rules
2376 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2377
2378 - Added new Monte Carlo histograms:
2379 MHMcEnergyImpact and MHMcEfficiency
2380
2381 - Added many new histograms needed for the flux calculation.
2382
2383 - Added a generalized histograms which can fill and show up to three
2384 data members in either a one-, two- or three-dimensional histogram, eg:
2385 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2386
2387 - Added:
2388 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2389 * calculation of <Theta> as a function of time (MHThetabarTime)
2390 they are needed in the flux calculation in
2391 order to select for a given bin in Theta (or time) the appropriate
2392 effective collection area, which is assumed to be given as a function
2393 of Theta and the true energy
2394
2395 - Added calculation of the migration matrix in the energy
2396 (MHMcEnergyMigration):
2397 the migration matrix describes the migration from the true (E_true)
2398 to the estimated energy (E_est); it is needed to determine the
2399 distribution of E_true from the measured distribution of E_est
2400 by unfolding
2401
2402 - changed the color palette in the camera display to DeapSea.
2403
2404
2405
2406 *** Version 0.6 (2002/01/15)
2407
2408 - Introduce the option of disable pixels (MBlindPixels and
2409 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2410 able to deal with Star Field NSB.
2411
2412 - Fixed a bug in the pedestals substraction
2413
2414 - Introduced verbosity levels
2415
2416 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2417
2418 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2419 work correctly (thanks to Abelardo)
2420
2421 - Introduced correct treatment of the diffuse Night Sky Background
2422 and NSB (MMcPedestalNSB)
2423
2424 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2425
2426 - Introduced MMcRunHeaders which contains monte carlo run informations
2427
2428 - Added a 'Print'-Task (MPrint) which calls the Print function
2429 of a parameter container for each event
2430
2431 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2432
2433 - changes to be more efficient with root 3.02/06
2434
2435 - root 3.02/06 fixes:
2436 + the memory leak when reading MRawEvtData
2437 + loosing more time than necessary to update the progress bar
2438
2439 - MWriteAsciiFile is now capable of writing more than one container
2440 in a line. For example: To be able to write Monte Carlo and
2441 Hillas values (energy and alpha) in one line.
2442
2443
2444
2445 *** Version 0.5 (2001/11/06)
2446
2447 - Added new GUI functionality (Analysis)
2448
2449 - Added a camera display to be able to display events in the camera
2450 together with the calculated hillas ellipse
2451
2452 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2453 object at any state of the analysis, so that the output are several
2454 states
2455
2456 - Fixed a bug in the collection area error calculation
2457 (Thanks to Ciro and Abelardo)
2458
2459 - Fixed a bug which causes merpp to crash in some environments
2460
2461 - Implemented auto enabling scheme for Branches to speed up reading
2462 a lot (see MReadTree and MTask)
2463
2464 - Fixed a bug in the Histogram classes which caused histograms to
2465 be written to a file by MWriteRootFile without request
2466
2467 - changed the object I/O from the old stylish root I/O to the new
2468 'auto evolution scheme' This was done only for classes which are not
2469 yet used in Monte Carlo files, so that these files are still readable.
2470
2471 - Added support for a progress bar in MEvtLoop and MReadTree
2472 (see the Analysis Window in Mars for an example)
2473
2474 - Fixed a bug in the package creation which disturbed the conversion
2475 between a mars version unpacked from a tar file and the repository.
2476
2477 - Changed the code to writer merpped (converted into root format)
2478 raw files, to get faster (around 10%)
2479
2480
2481
2482 *** Version 0.4 (2001/09/20)
2483
2484 - This release is made to compile on a root version >= 3.00
2485
2486 - Fixed a bug which causes MReadTree to read the first file only
2487
2488 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2489
2490 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2491
2492 - Added a task to write several container to a root file (MWriteRootFile)
2493
2494 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2495
2496 - Added calculation of the collection area (MMcCollectionAreaCalc)
2497
2498 - fixed some bugs in the Hillas calculation
2499
2500 - added filters to be able to control the task execution dependent on
2501 a parameter (for example: the number of level 1 triggers in a MC-file)
2502
2503
2504
2505 *** Version 0.3 (2001/04/23)
2506
2507 - Many demo macros added
2508
2509 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2510
2511 - Hillas Calculation added
2512
2513 - Standard image cleaning available
2514
2515 - MReadTree is now able to handle more than one file
2516 (Remark: of the same structure)
2517
2518 - Now we are able to display events in a first version of the
2519 Camera event display. To do this we must run the macro
2520 "macros/readCT1.C" to read data from CT1.
2521
2522
2523
2524 *** Version 0.2 (2001/01/24)
2525
2526 - First Implementation of a Gui to read the raw data. Start the
2527 gui with the command mars.
2528
2529
2530
2531 *** Version 0.1 (2000/12/20)
2532
2533 - First official release 0.1
2534
2535 - Changes:
2536
2537 + changed calling style of MRawPixelIterator from do...while to
2538 while-loop
Note: See TracBrowser for help on using the repository browser.