source: trunk/MagicSoft/Mars/NEWS@ 8676

Last change on this file since 8676 was 8676, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 106.0 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Now the output files (calib*.root, etc) also contain the
11 resource file (to check it open it in the TBrowser and choose Print()
12 from the context menu)
13
14 - general: Dataset files now allow to overwrite the default path
15 to search for sequence and data files. Note, that the program
16 option and individual resources will overwrite it. For example:
17 SequencePath: /magic/montecarlo/sequences
18 DataPath: /magic/montecarlo/star
19
20 - general: Fixed a problem with variables in MDataPhrase. It seems
21 that only optimdisp (didn't work) was effected.
22
23 - general: Some improvements to the optim and train processing. For
24 example the ststud window now got a proper title.
25
26 - general: The "Status Display: " was removed from the window title
27 within an Eventloop.
28
29 - merpp: Merpp can read file format version 9 now. Please realize
30 that for file format version 9 the extraction range is different
31 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
32 the first and last 15 slices have been removed from all MUX data.
33
34 - mars: Similar to writing movies you can now select events which
35 should be displayed in your display. Therefore add the following
36 lines to your mars.rc:
37 MFEvtNumber.FileName: ganymed00223552.root
38 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
39 The input file can be a ganymed-file after (ganymed*.root) or
40 before (ganymed*-summary.root) file. For example to select all events
41 from your on sample after cuts (excluding the ThetaSq cut) use
42 MFEvtNumber.Selector: DataType.fVal>0.5
43 To show all events from your on-sample after quality cuts
44 use the summary file instead.
45
46 - mars: new ways to call mars are implemented. Instead
47 of calling
48 mars filename.root
49 you can now also use
50 mars sequence.txt
51 or
52 mars sequence.txt inputpath
53 or replace sequence.txt by the sequence number if the default
54 sequence file should be used.
55
56 - mars: The default size has been increased
57
58 - mars: There are two new heckboxes which allow to switch off
59 the calculated image parameters
60
61 - callisto: was broken for MCs... fixed.
62
63 - callisto: improved calculation of spline coefficients a lot. This
64 leads to a further improvement of the event rate calibrating MUX
65 data of about 15% (175evt/s instead of 150evt/s)
66
67 - callisto: finally the raw data we read is now real 16bit (with
68 10bit precision) for MUX data and not a stripped 8bit number
69 anymore. Due to scaling of the numbers (without precision loss
70 into an [0-256[ range, the final numbers for pedestal, pedestalrms
71 and extacted signal don't change. However, at all places where
72 raw data is directly accessed (eg. saturation and variation
73 limits in the signal- and pedestal-extraction) the numbers
74 refer still to the data's 16bit range.
75
76 - callisto: The maximum arrival time difference used in the bad
77 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
78 for both, old FADC and MUX-FADC, data.
79
80 - callisto: Be aware that callisto is now calibrating the arrival time
81 in nanoseconds rather than time slices. Also all following tasks
82 have been changed to assume ns units now. If you star data
83 calibrated with an older version it might be necessary to adapt
84 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
85 to obtain optimal results. The plot in the PulsePos tab
86 will now be in ns, too. This might also mean that the Muon
87 analysis in star might not work as perfect as expected as long
88 as old files read in.
89
90 - star: For speed reasons events suitable for the muon analysis
91 are now also preselected by fConcCOG<0.1 which seems to be a very
92 good preselector for muons.
93
94 - star: is now calculating a new timing parameter the Slope along
95 the major and minor axis of the shower. Therefore a numerical
96 solution of a line-fit is used. To use MHillasExt.fSlopeLong
97 and MHillasExt.fSlopeTrans don't forget to multiply it with
98 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
99
100 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
101 have been removed from MNewImagePar. They have never been good for
102 anything.
103
104 - star: Implemented a new recursive algorithm which is supposed to be
105 faster. Also implemented new cleaning oiptions, which are:
106 + CleanLevel0:
107 The cleaning level above single core pixels can be kept
108 + KeepIsolatedPixels:
109 Define whether single core pixels should be kept
110 + TimeLevel1:
111 The coincidence window in nanoseconds to single used neighbors
112 + TimeLevel2:
113 The coincidence window in nanoseconds to two used neighbors
114 + PostCleanType:
115 MOde in which a time dependent post cleaning should be applied
116 0: No post cleaning
117 1: Require for each used pixels at least one used neighbor
118 within a time-window of CleanLevel1
119 2: Require for each used pixels at least two used neighbor
120 within a time-window of CleanLevel2
121 3: Require first two and second one used neighbor
122 within a time-window of CleanLevel1 and fCleanLevel2
123 respectively
124 + RecoverIsolatedPixels:
125 - recoveres isolated core pixels if they have a used neighbor
126
127 - mars/star: The new default cleaning is:
128 + CleanLevel1: 6.0
129 + CleanLevel2: 3.0
130 + CleanTime1: 1.75
131 + CleanTime2: 1.75
132 + PostCleanType: 3
133
134 - ganymed: The old hadronness and size cuts have gotten new indices
135 (10, 11). The old indices 8 and 9 now mean an additional condition
136 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
137 If you want to switch off this cut just move the line far away enough,
138 e.g. by setting c[9] to -500. Please update your ganymed.rc files
139 accordingly!
140 The unit of c[9] is deg. It is the dist at which your cut will
141 cross the slope==0. The unit of the slope is ns/deg. So if
142 you readin files calibrated with an older Mars-version you
143 have to adapt the default value for c[9] to the FADCs:
144 - Multiply by two for the MUX FADCs (run number > 200.000)
145 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
146 - Multiply by 42 for the meaning of life (run number = 200.000)
147
148 - ganymed: The old Cut0 is now called CutQ and is calculated before
149 the source position is caluclated. If you need a quality cut
150 including source dependant data (be very carefull with this!)
151 you have to use Cut0 instead.
152
153 - ganymed: now properly supports three off regions in wobble mode.
154 It will be the default from now on in ganymed_wobble.rc. To change
155 the number of off-regions use
156 NumOffSourcePositions: 1
157 in your ganymed.rc. Also by default no off-theta cut will be done
158 anymore so that you will get a background level higher than the
159 signal level in your ThetaSq plot for ThetaSq>0.2.
160 Due to this be carefull changing the scaling mode away from
161 "None". You will underestimate your signal if your scale interval
162 is not properly set.
163 (Rem: ThetaSqN is no longer needed)
164
165 - ganymed: is now storing the events of all (on- and off-)
166 source positions even in the case of more than one off-source
167 position. This should allow sponde to work properly and the
168 energy estimation is done correctly in all cases (without any
169 "nearest position" trick)
170
171 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
172 with a real pointing model for the starguider is done, calibrated
173 with more than thousand tpoints taken from this date on.
174
175 - ganymed: was broken for Wobble-MCs... fixed.
176
177 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
178 has changed. Note that your old ganymed.rc will be incompatible
179 with the new algorithms! Please check the ganymed.rc files and
180 the class description of MFMagicCuts for more information.
181 It is recommended at the moment to use identical Disp-Parametrizations
182 for on/off- and wobble-mode. If cuts are optimized only
183 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
184 should be optimized. All other values should be kept as they are.
185 If you want to do an anylsis without timing a parameters, you can
186 switch off the timing cuts by seeting parameter 7 to a very small
187 value (eg. -99). To remove the slope parameter from the disp
188 paremtrization set parameter 8 to 0.
189
190 - star/ganymed: The old spark-cuts have been replaced by new ones.
191 These new spark cuts have been cross checked with the sequences
192 84720 (before splitter), 101041 (after splitter) and 223539 (new
193 FADCs). In all cases they seperate pretty well, but of course not
194 perfect. Monte Carlos have suggested to tighten the cuts a little
195 bit further at low sizes. This has been done.
196
197 - ganymed: IMPORTANT - The spark cuts have been changed to match
198 all available data more or less well. This might mean that for
199 YOUR data there are still sparks visible.
200 Whenever you do an analysis you have to make sure that NO sparks
201 survive your cuts!
202
203 - ganymed: The distribution of observation time versus zenith
204 angle is now shown for off- AND on-data.
205
206 - optim, sponde: should now properly support three off-regions.
207 Just produce your ganymed summary files with three off-regions.
208 optim and sponde will automatically get all off events from
209 all off-regions from this file. Please do not forget to
210 set the scaling in optimwobble.C properly:
211 fit.SetScaleMode(MAlphaFitter::kNone);
212 fit.SetScaleUser(1./3);
213 it is not yet read in automatically (will follow soon).
214 In the case of fixed Scale you can also use
215 cuts.SetThetaCut(MFMagicCuts::kOn);
216 no off-cut needed.
217 Be carefull in case of three off-regions when switching on
218 scale mode. Make sure that the scale interval is set correctly.
219
220 - sponde: In the estimated energy versus monte carlo energy plot the
221 contents where exchanged.... fixed.
222
223 - sponde: the so called "accurate"-mode has been removed. It didn't
224 give any improvement in accuracy, only decreased execution speed.
225
226 - sponde: now checks whether the theta distribution of your on-data
227 and the theta-distribution of your Monte Carlo sample (after
228 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
229 sample is incomplete) execution is stopped. Execution can be forced
230 using the new option --force-theta. Use this option with care!
231
232 - sponde: Proper collection areas can now be constructed also from
233 Monte Carlo samples generated with different maximum impact
234 parameters. Note that in previous version you neither got
235 a warning or failure, nor was there any obvious sign that the
236 collection area was overestimated due to usage of files with
237 different maximum impact parameters.
238
239 - sponde: the output file now contains more information about
240 the spectrum (eg. the full 2D collection area histogram).
241 Note, that this information can only be written to the file
242 if it is stored automatically via command line argument.
243 If you only store the status display from within the display
244 the information is lost.
245
246 - sponde: added a new tab "EventDist" showing the unweighted event
247 distribution of your sample after cuts. This tells you how many
248 events with this energy you had in your MC files. The same information
249 you get from the error bars of the weighted histograms, but this is
250 less intuitive.
251
252
253
254 *** Version 1.2 (2007/05/14)
255
256 - database: The database now has two new values Unsuitable50 and
257 Unsuitable01. They express the number of pixels which are
258 unsuitable for more than 50%, respectively more than 1%, of
259 all calibrated event. It is a more accurate number than the
260 previously used numbers, because they only take the first
261 calibration (ignoring the interleaved calibrations) into account.
262
263 - database: The database now has two other new values UnsuitableMax and
264 DeadMax. They express the maximum number of pixels which were
265 unsuitable, respectively dead, during the sequence. Because
266 of high pedestal rms (cars passing) a few events with very high
267 numbers of unsuitable pixels can happen. Not to suffer from this
268 effect we don't take the highest 0.1% of the numbers into account.
269
270 - general: fixed a bug which caused callisto and star to stop working
271 properly because the callisto output was currupted
272
273 - general: a script called scripts/makemovie has been added which
274 simplified the process of producing several movies from a single
275 sequence with different setup.
276
277 - callisto: Some more code cleanup. Started to remove old obsolete
278 code from cvs.
279
280 - callisto: The extraction of the pedestal with the extractor was
281 not random. It seems that extracting at one position is still biased
282 (for example in the first or last slices we could still suffer from
283 switching noise) Now it is completely random.
284
285 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
286 pedestal files) individual pixels could be skipped due to high
287 variations. This was already the case for the pedestal extraction
288 from the lo-gains since the beginning and properly handled
289 there, but was introduced in the extraction from the pedestal files
290 a while ago. To calculate the average value it was still divided
291 by the number of events procesed not by the number of summands
292 really summed. This let to a pedestal which was a tiny amount too
293 small (for a few piels in the order of 0.1%). This led to an slightly
294 positive offset of the randomly extracted pedestal for a few pixels.
295 I doubt that this has a big effect on the result, because the effect
296 on the individual numbers is quite small. Due to this it is suggested
297 that you rerun your calibration to make sure you are without any
298 avoidable bias.
299
300 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
301 the median rms of the absolute arrival time and expressed in significance
302 levels. This replaces the old meaning of an abolute upper limit. An
303 absolute upper limit doesn't make much sense, because in our data
304 all arrival times are shifted at the same time (in fact it might be
305 a shift of the artificial trigger w.r.t. to the light flash).
306
307 - callisto: Added a new tab "BadPixTm" which shows the time evolution
308 of the number of unsuitable pixels over the whole sequence. This
309 is usefull mainly to judge if an intermediate calibration had
310 problems.
311
312 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
313 of the number of dead pixels over the whole sequence. Dead pixels
314 in this context are unmapped pixels, i.e. pixels which could not
315 be interpolated, and thus are ignored in the further analysis.
316
317 - callisto: It is now possible to use the position of the maximum
318 of the spline as arrival time instead of the leading edge even
319 when using the integral for the signal. Therefor set the extraction
320 type to kIntegralRel ("IntegralRelative") and the relative height
321 ("HeightTm") to -1:
322 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
323 MJPedestalC1.ExtractSignal.HeightTm: -1
324
325
326
327
328 *** Version 1.1 (2007/04/27)
329
330 - general: The new class MGeomCamDwarf contains the camera geometry
331 for our prefered Dwarf camera and can be used to create general
332 geometries of roundish or hexagonal cameras.
333
334 - mars: The default cleaning is now abolute 8.5/4.0.
335
336 - mars: The resource file mars.rc now contains examples for MUX data
337
338 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
339 data containing only 10-bit information is still cooked down to
340 8-bit, by cutting away the lowest 8-bit.
341
342 - merpp: When reading raw data the data is now stored in a single
343 array. The lo-gain array is obsolete. The interface stays the same.
344
345 - callisto: To process the new MUX data use the resource file
346 callisto_mux.rc
347
348 - callisto: The -root and -raw options to read merpped raw data have
349 been removed
350
351 - callisto: If the -mc option is given the sequence-name can now be
352 replaced by the MC sequence number
353
354 - callisto: If the sequence file contains "MonteCarlo: Yes" the
355 -mc option can now be omitted
356
357 - callisto: Started further simplification by removing obsolete
358 dependancies on MCalibIntensity*Cams.
359
360 - callisto: removed unsused intensity calibration from MJCalibration
361 for further simplification
362
363 - callisto: for simplification removed references to
364 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
365 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
366 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
367 (this should at minimum change nothing at all, and at maximum
368 improve thing if these containers where somewhere not handled
369 properly)
370
371 - callisto: Added the option to write an event movie. Please use
372 this option with care (huge files) but exessively to understand
373 our events. For further documentation please refer to the
374 IACT wiki
375 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
376
377 - callisto: Improved binning for the pulse position check histogram
378
379 - callisto: The code calculating the pulse position checknow takes
380 the pedestal into account
381
382 - callisto: The arrival time is now stored with full precision this
383 helps to get rid of artefacts in histograms. For the signal this
384 is not necessray because it is displayed in log-scale anyhow
385
386 - callisto: Fixed a problem with internal exclusions. Pixels which
387 have once been marked as unsuitable didn't get the necessary
388 histograms filled anymore to be rechecked with each interleaved
389 calibration.
390
391 - callisto: The relative arrival time resolution (the rms of the
392 relative arrival time offset) is now checked against its
393 median and the median deviation, instead of the average
394 plus an absolute offset.
395
396 - callisto: The relative arrival time offset is now calculated
397 w.r.t. its median not w.r.t. to an artificial reference pixel.
398
399 - callisto: The relative time calibration now marks pixels with
400 outlaying offset as unsuitable
401
402 - callisto: The interleaved relative time calibration has been switched
403 on. The advantage is that pixels which are marked as outliers
404 now can recover. An improvement over time is not expected, because
405 the relative time calibration seems stable.
406
407 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
408 option can now be omitted.
409
410 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
411 or the option "-mc" is specified as default the monte carlo datacenter
412 paths (/magic/montecarlo/...) are used if not overwritten in the
413 dataset file.
414
415 - ganymed: The output files now contain run- and event-number for all
416 events, accessible as RunNumber.fVal and EvtNumber.fVal
417
418 - ganymed: Added a plot showing the source position in the camera also
419 for wobble mode
420
421 - ganymed: In addition to the existing task which can be setup to
422 be executed after Cut1 a final task called "EstimateEnergy"
423 has been added, executed before writing the final output
424 (ganymed00000000.root). The task setup in all three cases
425 can be choosen individually. (For all three(!) cases you
426 can for example choose MRanForestCalc. For examples see all
427 sponde*.rc and all ganymed*rc)
428
429 - ganymed: If a container "MEstimatedEnergy" is found in the
430 parameter list (eg. because it was setup by MEstimateEnergy)
431 it will be written to the output file.
432
433
434
435 *** Version 1.0 (2007/02/16)
436
437 - database: Website to plot values from the database has been added.
438
439 - database: The rate of spark events as found by star is now kept
440 and the rate after cleaning is now with spark events subtracted
441
442 - general: The changes to the interpretation of phrases lead to
443 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
444
445 - general: Added example files how you can create your own calendar
446 (eg. as christmas present) with Mars. Just run
447 root macros/tutorials/calendar.C
448
449 - general: Added a possibility to display grouped data in the plotdb.C
450 macro (and similar macros). This allows to plot hourly, nightly,
451 weekly, monthly and yearly averages.
452 For more details see the plotall function of the macro
453
454 - general: fixed the error display of the camera display. It showed
455 wrong results.
456
457 - general: fixed a memory leak when reading many MStatusDisplays
458
459 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
460 between a spherical and a parabolic mirror
461
462 - callisto: We have a new pulse position check which takes the properties
463 of the extractor automatically into account. So no need to set
464 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
465 left is done. If possible the lo-gain extraction start and hi-gain
466 extraction end is changed accordingly. If no proper extraction range
467 can be set (hi-gain too much to the left) an error is raised.
468
469 - callisto: New swapped pixels have been found and corrected
470
471 - callisto: Redone the signal extraction this includes:
472 + Unified the algorithms to extract the pedestal for all pedestal
473 extractions done
474 + Unification of hi- and lo-gain into one array
475 + Unification of hi- and lo-gain extraction for Spline and
476 Digital Filter (means now exactly the same algorithm is used,
477 not a copy-and-pasted one)
478 + Store pedestal subtracted data in a common place
479 + Improved extraction algorithms. If the algorithms search a
480 maximum but don't find one they don't return the maximum anymore
481 + Improved the extraction such that a information for signal
482 and time which is consistent is returned
483 + replaced the numerical spline with a (not slower) analytical
484 solution
485 + Lowered the saturation limit from 250 to 245 to make sure that
486 we are far away in all pixels from problems with the clock-noise
487 + The start of the lo-gain extraction is calculated from the hi-gain
488 arrival time. In case of saturation an estimation is used.
489 + the hi-gain window was extended to slice 16. This allows extraction
490 of very late pulses in single pixels or of huge hadron showers.
491 + Now uses the lo-gain extraction range for pedestal extraction,
492 not the hi-gain range in the lo-gain
493
494 - callisto: New hi-/lo-gain calibration constants have been produced
495 for all periods from the statistic of the whole period. They are
496 now used automatically depending on the periods. The old constants
497 where deviation in avarega about 2%-3%. The constants are very
498 stable from period to period (<<1%) except for exchanged channels.
499 In a few cases the constants used so far were off by 1%-2% (maybe
500 temperature effects?)
501
502 - callisto: To gain obsolete space we do not write the
503 MPedestalFundamental anymore. Also calibration and bad pixel
504 treatment is not done for it anymore because it has never been used.
505
506 - callisto: Fixed a bug in the seuqence handling which caused the
507 light condition to be ignored
508
509 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
510 basically the same as "Cleaned" but the distribution devided into
511 the events fullfilling a spark cut or being rejected by it.
512 This cut can be changed from star.rc (see example inside) by
513 the "SparkCut" directive
514
515 - star: Star displays now the average individual pixel-rate (IPR) versus
516 time and the average discriminator threshold (DT) of all pixels.
517
518 - optim: fixed a problem with the optim-macros which was due to a bug
519 in the new phrase parsing
520
521 - ganymed: To get a nice FalseSource plot (instead of the all-information
522 debug plot displayed as a standard plot) use the context menu
523 somewhere between the two upper plots, click on "DrawNicePlot"
524 and enjoy the result. (It is the same context menu which contains
525 the other options)
526 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
527
528 - ganymed/optim/train: The cut program, trainings- and optimization
529 macros could run with less files found than expected from the
530 sequence-files. No the execution is stopped in this case.
531
532 - ganymed: now stores the dataset in the output file with all information
533 contained (as sequence number, sequence path, data path) so that the
534 used dataset file can be recreated complete from the output
535
536 - sponde: now also allows the uasge of random forest
537
538 - sponde: added a plot showing the cut efficiency
539
540 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
541 errors (eg. effecting the collection area) because the errors of the
542 two histograms were swapped in the calculation, which makes a difference
543 in the case the histograms contains weighted events. Aditionally the
544 totalarea was incorrectly taken into account, which results in too small
545 errors, which makes a difference at low statistics were the errors
546 or the collection area dominate.
547
548
549
550 *** Version 0.10.3 (2006/10/23)
551
552 - database: Implemented ObservationMode flag in websites.
553
554 - database: For sequences there is now also the stoptime available on the
555 websites.
556
557 - database: Removed ManuallyChanged flag from sequence-info websites,
558 as it is not needed anymore with the new sequence building algorithm.
559
560 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
561 Class for calculation of confidence intervals (upper limits).
562 Use model 3 or 4 for upper limit calculation for MAGIC observations.
563 Please read the class instruction of TRolke for more information.
564
565 - general: The programs now return 0xfe if the requested resource file
566 doesn't exist.
567
568 - general: Errors comming from root itself are now not output to
569 stderr anymore but to our default (colored) log-stream.
570
571 - general: Changed the interface to TFormula such that now everything
572 is parsed by TFormula, which should allow to use phrases even
573 without paranthesis correctly parsed.
574
575 - callisto: replaced the AdHoc number of effective integration slices
576 in the digital filter by an average of the correct number, averaged
577 over all possible set of weights. This also gives correct numbers
578 for the lo-gains which were totally wrong before.
579
580 - callisto: drastically reduced memory consumption by not storing
581 all intermediate calibration results in memory anymore (we might
582 write them into a file in the future)
583
584 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
585 debug plot displayed as a standard plot) use the context menu
586 somewhere between the two upper plots, click on "DrawNicePlot"
587 and enjoy the result. (It is the same context menu which contains
588 the "DrawAll" option)
589 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
590
591
592
593 *** Version 0.10.2 (2006/10/15)
594
595 - general: changed the building of the sequence files such, that
596 the source-/project name in case of wobble-sources is not the
597 source/project of the first data run anymore but the new generalized
598 wobble source/project
599
600 - general: Added some functions to MAstro to calculate sun and
601 moon properties
602
603 - general: Added two new macros (starvisday.C and starvisyear.C)
604 which allow to plot the visibility of several stars in one day
605 or of one star along one year
606
607
608
609 *** Version 0.10.1 (2006/10/11)
610
611 - general: HTML logging output was distorted... fixed.
612
613 - general: Changed the writing of the sequencefiles such that only
614 as many pedestal files as giving at least 1000 pedestal events which
615 are nearby the first calibration run are used as pedestal runs
616
617 - sponde: In the calculation of the collection area(s) and the
618 distribution for MOnte Carlo and estimated energy the error
619 calculation was wrong because root didn't take the errors
620 properly into account... fixed.
621
622
623
624 *** Version 0.10 (2006/10/10)
625
626 - general: all executables now check consistency of the root version
627 installed with the root version used for compilation. The return
628 code in this case is 255.
629
630 - general: The algorithm to build seqeunces has been redesigned
631 completly. It is now more flexible in terms of a resource file
632 resources/sequences.rc which can be used to partly overwrite
633 the default algorithm and defined the important part of the
634 algorithm. It also takes correctly into account several ways
635 of taking wobble-data. Currently the new algorithm doesn't take
636 the number of pedestal events anymore into account (so a sequence
637 could have much less than 1000 pedestal events and data runs are
638 no-more used instead)
639
640 - general: a lot of small changes to make the code compatible with
641 root 5.12/00 and gcc 4.1
642
643 - general: Fixed some warnings thrown if more warnings are switched
644 on in the compiler
645
646 - general: Added a function to MMath which returns the Median of
647 the distribution abs(y[i]-median) but at 68:32 division instead
648 of 50:50, which is somehow the median counterpart of the rms.
649
650 - general: MAstroCatalog allows now to read calatog files (as bsc5)
651 even if they are compressed with gzip (recommended compression
652 is with "-1")
653
654 - showplot:
655 + batch mode creation of image files now works with root 5.12/00
656 + added support for writing bmp (though it never produces
657 bmp which can be read by programs like xv or gimp)
658 + added support for xml
659 + added new option to start the display with a different size, by
660 --display-width=nnn or --display-height=nnn
661 + added options to define the canvas size when the display is started
662 --canvas-width=nnn or --canvas-height=nnn
663 the option can also be used for batch-mode conversion
664 + added an option which automatically fits the display size to the
665 desktop-size: --auto-size
666
667 - merpp: didn't recognize files with the extension .raw.gz - fixed.
668
669 - merpp: allow the reports to have 1000ms due to a bug in the camera
670 program.
671
672 - callisto: New swapped pixels have been found and corrected. For
673 details see MRawRunHeader::FixAssignment()
674
675 - callisto: Callisto now raises an error if one of the input files could
676 not be opened.
677
678 - callisto: In some rare cases it could happen that in the signal
679 extraction of the digital filter the extractor returned nonsense
680 results due a wrong initializion of a variable (this happens in
681 cases in which the extracted signal is exactly zero or the
682 digital filter couldn't slide because of a too small extraction
683 window, which could happen in the lo-gain extraction)
684
685 - callisto: The lo-gains have been marked as valid in some cases
686 when they got not extracted at all (deltsumlo=deltatimelo=0) because
687 the allowed extraction range (fLoGainLast-fLoGainFirst) was
688 smaller than the number of slices (fLoGainWindowSize) needed
689 by the lo-gain extractor
690
691 - callisto: Updated absolute calibration constants (muon calibration)
692
693 - callisto: fixed a bug which caused the hi-gain saturation not
694 to be handled properly in the spline (the position of the
695 saturation was calculated incorrectly)
696
697 - callisto: fixed a bug which gave weird results if hi- _and_
698 lo-gain could not be extracted properly. In some cases hi-
699 and lo-gain have not been extracted at all and the random result
700 got calibrated. In other cases the hi-gain was saturating and the
701 lo-gain has not been extracted. For this a completly arbitraty
702 scale factor was applied to the result from extracting the
703 charge of the saturating hi-gain.
704
705 - callisto: improves handling of extracted signal if lo- and/or
706 hi-gain could not be extracted properly. If no appropriate
707 calibration of either the signal or the arrival time is possible
708 the pixel is now markes as unsuitable instead of estimated.
709
710 - callisto: Fixed a problem in the spline extraction which gave
711 weird results if the signal was extracted from the first (and
712 highest) slice (as a workaround extraction from the first
713 slice has been forbidden)
714
715 - callisto: Fixed a bug regarding the use of the QE which doesn't
716 effect the result because the default is used anyhow.
717 (The bug was there since 14/07/2005)
718
719 - callisto: Changed the default for fgLoGainStartShift to -2.4
720
721 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
722 factors to be always 10 for all pixels as soon as the first
723 calibration update has happend.
724
725 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
726 was off by more than one slice (which gives wrong values for
727 pixels which have saturated the hi-gain) This was a problem
728 mainly for timing studies, not so much for the automatic standard
729 analysis. Also the values for the Spline have been changed slightly:
730 + Digital Filter from 1.70 to 0.95
731 + Spline from 1.39 to 1.30
732 The numbers were sorted out by an extensive test in the
733 test-database.
734
735 - callisto: Removed the tab showing the average calibrated arrival
736 time. It never gave useful information.
737
738 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
739 lo-gain pulse for data pulses if hi- and lo-gain have saturated
740 and both were extracted because the hi-gain was above the
741 LoGainSwitch.
742
743 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
744 lo-gain pulse position (after application of LoGainOffset, which
745 means in the ideal case it is 0) for data pulses if hi- and lo-gain
746 have saturated and both were extracted because the hi-gain was above
747 the LoGainSwitch.
748
749 - callisto: After extensive tests a new threshold level for determination
750 of the pulse position has been found at 50phe. This is due to the
751 fact that for lower pulses the arrival time changes its average
752 behaviour dramatically. It tends to the average of the extraction
753 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
754
755 - callisto: Added two more plots to the calibration part. The average
756 extracted signal and the average extracted arrival time as
757 extracted by the signal extractor (This can help debugging problems
758 because it doesn't involve a fit)
759
760 - star: changed the fit for the effective on time such that initial
761 values are calculated automatically now instead of using build
762 in values. This makes the fit more indepedant of the underlaying
763 rates. With a test of ~350 sequences in the test database it could
764 be shown that the new fit gives the same result +/-1sek.
765 The highest deviation was +5s the lowest -10s. You can now control
766 the bahaviour with two resource values:
767 MHEffectiveOnTime.FistBin: 3
768 MHEffectiveOnTime.NumEvents: 12000
769 Use FirstBin=1 and NumEvents=120 to fit the effective on time
770 from the resulting gamma candidates
771
772 - star: The Center histogram in MHHillas is now by default displayed
773 with the colz draw-option
774
775 - ganymed: now produces valid error codes if failed
776
777 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
778 with the option "hadronness" instead of "area" or "both" if
779 you want to use both cuts. The hadronness cut includes a fixed
780 cut in hadronness (index 8) and a fixed cut in size (index 9).
781
782 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
783 the M3Long of the anti source to be not properly evaluated
784 (actually is was evaluated as a unique random number) in case
785 of optimization with anti-theta cut switched on. This might have
786 lead to improper, but not necessarily wrong, optimization results.
787
788 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
789 how to use random forest
790
791 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
792 ganymed_onoff.rc. Seems to be unintentional that they were different.
793
794 - sponde: Since the introduction of the possibility to define a
795 normalization energy instead of using the integral the default
796 was not using the integral anymore but a normalization energy of
797 1GeV. It is now the integral again.
798
799 - sponde: Fixed a problem in the weighting which did not allow
800 a MC slope of -1.
801
802
803
804 *** Version 0.9.6 (2006/05/24)
805
806 - general: changed the binning of the azimuthal profile of the camera
807 such that it is aligned with the 60deg boundaries.
808
809 - merpp: better handling of problems with the TH, TD part of the
810 CC-REPORT for files older than 200507190 and 200412210
811 respectively
812
813 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
814
815 - merpp: implementd latest changes in starguider reports (sinc 9th May)
816
817 - callisto: if an arrival time is extracted outside the fadc range is
818 was set to the boundary before. Now a random number is assigned
819 instead to avoid unfortunate coincidences of arrival times just
820 by this arbitrary value.
821
822 - callisto: added a new option to callisto.rc which allows
823 to set the maximum arrival time difference allowed for the
824 badpixel algorithm to determin whether a pixels belongs to a shower:
825 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
826
827 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
828 to 0.9 as suggested by Stefan due to a recent study on the fraction
829 of pixels surviving the image cleaning
830
831 - callisto: switched off error in case of "pulse is too much to the left"
832
833 - callisto: The extraction window is not adapted anymore. This means that
834 the pulse is extracted from the full range. The draw-back is that the
835 background (pedestal) will become slightly higher. Switching on/off
836 the PulsePosCheck in the callisto.rc only effects filling the
837 histograms.
838 WARNING: If the pulse is too much to the left data is calibrated!
839 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
840 in the database to make sure that your data is valid!
841
842 - star: Show also the number of stars correlated correctly by the
843 starguider
844
845 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
846 than one off-source region in wobble-mode. To use it add the following to
847 your ganymed_wobble.rc:
848 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
849 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
850 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
851 + Cut1.ThetaCut: None
852 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
853
854 - ganymed: in the case the latest report is older than a default (currently
855 one minute) and the current report will be skip the starguider
856 correction and calibration will be reset. The maximum age can be
857 setup from ganymed.rc by (minutes):
858 MPointingDevCalc.MaxAge: 1.5
859
860 - ganymed: A first implementation showing all size-bins for the theta-sq
861 resp. alpha-plots in a single tab automatically
862
863
864
865 *** Version 0.9.5.1 (2006/05/05)
866
867 - general: Added a new option "zdiff" to the Makefile which runs
868 "cvs diff" as "make diff" would do, but with compression
869
870 - general: accelerated MTFillMatrix (used for eample in all training
871 and optimization macros) by skipping some obsolete calles in the
872 eventloop the first and second loop could be accelerated by ~20%
873
874 - general: Added a missing feature in the MFilterList class which
875 prevented MFEnergySlope from working correctly in trainenergy.C
876
877 - general: Accelerated the random forest training and usage a bit
878
879 - merpp: Adapted to new raw data file format version 6
880
881 - merpp: fixed a problem with reading the starguider reports
882 after 6.3.2006
883
884 - callisto: At some times six pixels had to be exchanged manually in the
885 data. If the pixels to be swaped are both not found, an error was raised
886 and calibration was stopped. Now it is assumed they are intentially not
887 mapped and the Error has been changed to a Warning.
888
889 - star: Added new image cleaning based on the arrival time of the shower.
890 The new cleaning can be accessed using the parameter "Time" instead of
891 the the old one (like "Absolute) in the star.rc-file.
892 Recommended parameters:
893 + MImgCleanStd.CleanLevel1: 8.2
894 + MImgCleanStd.CleanLevel2: 5
895 + MImgCleanStd.CleanRings: 2
896 + MImgCleanStd.KeepSinglePixels: No
897
898 - star: Simplified the calculation of the effective on time. By letting
899 the fit start in the third bin the result should become more stable.
900 The fit quality is now ignored for the theta-plot which is not used
901 in the analysis later. Still better pre-cut which, for example,
902 remove events triggered by car-light (rate changing on a short
903 time-scale) are missing.
904
905 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
906 for optimization (kWeakSource) which is suggested by the Berlin
907 people for weak sources.
908
909 - macros: plotdb.C:
910 + if no dataset and no time-interval is given only sequences with
911 an effective on-time above five minutes are plotted anymore
912 + added a new tab "RelTime" displaying the relative on-time
913 (effective on-time divided by the observation time)
914
915 - macros: optim*.C: by skipping some obsolete calles in the eventloop
916 the optimization became a lot faster
917
918 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
919 To display them just delete the pads displayed on top.
920
921 - ganymed: fixed a bug which could cause strange behaviour in wobble
922 mode if no starguider information was available due to an incorrect
923 initialization of the starguider calibration
924
925 - ganymed: The scale region in the False Source Plot (MHDisp) can now
926 be changed from within the plot. It can also be setup from the
927 resource file using:
928 + MHDisp.fScaleMin: 0.325
929 + MHDisp.fScaleMax: 0.475
930
931 - ganymed, showplot: Fixed a problem with the fit to the off-data
932 (HistOff) which could cause a time lag or an inifinite loop.
933 The bug did not effect the results at all.
934
935 - sponde: Added a new tab showing the effective collection area after
936 trigger (including the software trigger)
937
938 - sponde: MMcSpectrumWeight has a new option which allows to define
939 the scaling factor not by the integral of the events but at
940 a defined energy:
941 e.g. MMcSpectrumWeight.NormEnergy: 200
942
943 - MTFillMatrix, sponde: by skipping some obsolete calles in the
944 eventloops the loop could be accelerated by ~20%
945
946
947
948 *** Version 0.9.5 (2006/03/13)
949
950 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
951 and added the standard Disp-parametrization
952
953 - macros: added a new macro datacenter/macros/plotstat.C allowing
954 to plot statistics about the data processing
955
956 - macros: added a new macro to plot the muon correction coefficients
957 versus period (macros/plot/mucal.C)
958
959 - showplot: path inflation for ganymed files was broken
960
961 - callisto: Fixed an important bug. When the number of saturating pixels
962 were calculated the bad pixel information already available from the
963 calibration was ignored. This yields wrong values in case pixels
964 are broken and saturate all the time or randomly.
965
966 - callisto: Updated Muon calibration constants. Spline data now also uses
967 different values for different periods
968
969 - star: The time-evolution shown in the effective on-time plot now displays
970 the axis range (if there are no holes it should be similar to the
971 effective on-time)
972
973 - star: Added two new image parameters:
974 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
975 the three pixels next to the center of gravity and the size
976 + MNewImagePar.fConcCore: The ratio of the signals of all
977 pixels inside or touching the ellipse and the size
978
979 - ganymed: now stops in requested source isn't found in catalog file
980
981 - ganymed: Many improvements to the phi-plot in wobble mode:
982 + with a template the ideal background is displayed
983 + a possible camera inhomogeneity is taken into account
984 + the anti theta cut is better supported
985 + the phi cut is automatically calculated from the theta cut
986 See the examples in ganymed_wobble.rc for more details.
987
988 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
989 times the bin-width instead of the absolute energy
990
991 - ganymed: New cuts for on/off and wobble mode
992
993 - ganymed: The smearing of the False Source plot has been increased
994 to 0.06
995
996 - ganymed: The starguider calibration can now be changed from the
997 resource file.
998 See the examples in ganymed*.rc for more details.
999
1000 - ganymed: added a new option for on-/off-observations
1001 MJCut.RandomSourcePosition
1002 If switched on the distribution of observation time of the source
1003 position in the camera is calculated from the on-data and randomly
1004 applied with this distrbution to the off-data.
1005
1006 - ganymed: by skipping some obsolete calles in the eventloop the
1007 first and second loop could be accelerated by ~20%
1008
1009 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1010 position in the off-data randomly according to its distribution in the
1011 on-data.
1012
1013
1014
1015 *** Version 0.9.4.3 (2006/02/13)
1016
1017 - general: Fixed a bug in most of the programs which prevented the
1018 compile date in the startup message to be displayed
1019
1020 - general: Simplified program calls. The following abbreviations
1021 are now possible:
1022 showlog callisto 55599
1023 showplot signal 55599
1024 star 55599
1025 callisto 55999
1026 ganymed 2
1027 In this cases the corrsponding root-, log-, sequence- or dataset-
1028 filename is automatically compiled using the default datacenter
1029 paths ("/magic/*")
1030
1031 - general: Fixed a long outstanding bug which made axis tick marks
1032 disappear if MDataFormula was used (eg. abs(x))
1033
1034 - general: Updated MMath with new functions to calculate the results of
1035 a exponential, logarithmic and powerlaw fits analytically.
1036
1037 - general: Updated some macros with comments:
1038 + macros/optim/optimdisp.C
1039 + macros/optim/optimenergy.C
1040 + macros/optim/optimwobble.C:
1041
1042 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1043 files) now allows adding a pre-cut like in the optimization. E.g. this
1044 is useful to perform g/h-separation cuts before training the random
1045 forest.
1046
1047 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1048 correctly assigned in the raw data assignement table. A fix to correct
1049 the assignment tabel have been implemented.
1050
1051 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1052 by 90, 180 and 270 deg.
1053
1054 - general: the macro plotdb.C now allows to highlight sequences belonging
1055 to a datset. For more details see the descritions in the macro.
1056
1057 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1058 of the display, it gave wrong results espacially for big sizes.
1059 Now the embedded canvas should always have a ratio width/height=3/2.
1060 The "Size" options have been updated with values fitting the 3/2
1061 size ratio.
1062
1063 - RanForest:
1064 + Updated the random forest classes to support also the
1065 regression method implemented by Thomas H.
1066 + added new tutorial macro how to train the random forest
1067 for energy estimation (macros/optim/rfenergyest.C)
1068 + new classes to train the random forest (still in development)
1069 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1070 + new tutorial macros for random forest training in macros/train
1071 trainenergy.C, traindisp.C, trainseparation.C
1072
1073 - mars: now allows to setup a cut in the resource file mars.rc to choose
1074 the events to be displayed, eg:
1075 Cut.Condition: {0} && {1}
1076 Cut.0: MHillas.fSize>100
1077 Cut.1: MHillas.fSize<900
1078
1079 - merpp: Made aware of the new .rep format 200510250. This includes
1080 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1081 the discriminator thresholds (MCameraTD) and the disciminator
1082 delays (MCameraTD). All of them come with the CC report and are therefor
1083 written to the CC tree.
1084
1085 - callisto: fixed a bug in the calculation of the arrival times in
1086 the Digital Filter. They were all shifted by the same amount
1087 fHiGainFirst. This caused an offset in the order of the position of
1088 the left border of the extraction window in the times calculated
1089 from high-gain and from low-gain. The bug effected only the absolute
1090 arrival times. The bug was there since 30.1.2005.
1091
1092 - callisto: Changed the ExtractionWindow for the pulse position check
1093 such that the camera inhomogeneity becomes as less as possible and
1094 comparable to the pulso position check switched off. More details
1095 on the study will be given at our result web-page.
1096
1097 - ganymed: ganymed.rc, ganymed_onoff.rc:
1098 changed to new cuts trained with 1ES1218 and Crab-data
1099 for maximum sigma*log10(excess)
1100
1101 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1102 a new option was implemented to estimate Disp (CalcDisp)
1103
1104 - ganymed: Implemented two new options which allow
1105 to overwrite the default path to search for the sequence files
1106 --ins=/magic/sequences
1107 and where to search for the image data
1108 --ind=/magic/data/star
1109
1110 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1111 dx/dy from the resource file by
1112 MSrcPosCorrect.Dx
1113 MSrcPosCorrect.Dy
1114
1115 - ganymed: fixed reading the source catalog. Only as many chars
1116 as the requested source name had were compared (If a source
1117 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1118 were requested it could happen that the coordinates of
1119 "1ES1218" were read) The source coordinates are now printed
1120 in addition to its name to the logging output.
1121
1122 - ganymed: changed the background fit in the case of a ThetaSq function
1123 from a polynomial to a exponential, this should give a big improvement
1124 for on-only analysis'
1125
1126 - ganymed/sponde: Calculation of the error of single size-/energy-
1127 bins now uses Li/Ma (5) instead of LiMa (17)
1128
1129 - sponde: Added a plot E^2*dN/dE
1130
1131 - sponde: The energy estimator plot should now show values like
1132 they are commonly used.
1133
1134 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1135 (a powerlaw with cutoff didn't work before)
1136
1137
1138
1139 *** Version 0.9.4.2 (2005/10/01)
1140
1141 - general: added new tutorial macro macros/tutorials/threshold.C:
1142 how to calculate the threshold
1143
1144 - general: added a new game. Start it from the interpreter with
1145 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1146 and MagicReversi)
1147
1148 - general: neighbor pixels in MGeoms are now sorted clockwise
1149
1150 - merpp: made aware of new format 20050829-0
1151
1152 - callisto: New scale factors from muon analysis, stored in new
1153 resource file resources/calibration.rc
1154
1155 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1156 the eventloop if something went wrong. This is necessary for the
1157 automatic processing
1158
1159 - callisto: Implemented a new treatment for the time information
1160 developed by S.Ruegamer, this should give much better response than
1161 the old very primitive algorithm. This is especially important
1162 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1163 treatment was buggy! As neighbor pixels to interpolate the
1164 arrival times always the pixels 0 to 5 were taken)
1165
1166 - callisto: In addition to the new treatment of arrival times the
1167 decision of the treatment whether a pixel contains shower
1168 information or not is used to improve the signal interpolation
1169 further. Previously interpolated pixels showed a non-zero signal
1170 do the peak searching signal extractors. Having a signal pixel
1171 beside raised the signal above the cleaning level. Thus the
1172 pixel survived cleaning to often but with a too low mean signal.
1173 By replacing empty pixels with a gaus (mean and rms from the
1174 corresponding Area entries in MPedPhotCam) this effect can
1175 be supressed.
1176
1177 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1178 got lost when the events were stored by the calibration... fixed.
1179 (This was no problem for normal image cleaning because the pixel
1180 content was artificially set to 0 not surviving standard cleaning
1181 algorithm)
1182
1183 - callisto: Fixed a bug which caused the random and peak-search pedestal
1184 extracted with an extractor to be exchanged for the first (roughly)
1185 500 events (*Extractor and *ExtractorRndm).
1186 (They were simply exchanged in callisto.cc) This bug might have been
1187 introduced in Mars 0.9.4 when the order of calculation of the two
1188 types of pedestal in callisto got exchanged. The bug only effects
1189 the first seconds of data of each sequence.
1190
1191 - star: Taking the arrival time of Muons into account the calculation
1192 of the parameters could be made independant of the noise
1193 (pedestal rms). The dependance was due to the bias of the peak search
1194 extractor. Now only a ZA dependamcy is left which is not yet fully
1195 understood.
1196
1197 - ganymed: The sequences were still not sorted correctly in any case,
1198 because they were sorted by the full qualified path name. Now they
1199 are sorted by their sequence number.
1200
1201 - ganymed: new values for the spark-event-cut
1202
1203 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1204
1205
1206
1207 *** Version 0.9.4.1 (2005/08/18)
1208
1209 - callisto: fixed some problems with the calibration in case of
1210 inteleaved events. Therefor the final and some intermediate
1211 fits are skipped which would take place on partly filled #
1212 histograms and gave wrong results or failed completely.
1213
1214 - callisto: If the intermediate finalization of the histograms
1215 calculating the mean charge of the calibration signal fails
1216 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1217
1218 - ganymed: Fixed some bugs which caused problems in On-only mode.
1219 Still the false source plot doesn't give reasonable results.
1220
1221
1222
1223 *** Version 0.9.4 (2005/08/05)
1224
1225 - general: Fixed the ZA binning. It did not correctly fit the
1226 MC binning
1227
1228 - general: Added a class to correct for the missfocussing in
1229 April (MSrcPosCorrect)
1230
1231 - general: Random Forest energy estimator should now work properly
1232
1233 - general: MHCamera now displays the profiles in deg instead of mm
1234
1235 - general: MH::SetPalette offers a lot of new palettes
1236
1237 - general: MHillas - the case of CorrXY==0 is now handled properly
1238
1239 - general: implemented the possibility to change the line and
1240 marker style of a sky-grid drawn by MAstroCatalog
1241
1242 - general: Runs in sequences and datasets are now automatically
1243 ordered (it is assumed that the order of their filenames correctly
1244 represents the order of observations) to ensure correct reading
1245 of the subsystem data
1246
1247 - general: Runs cannot be added to a sequence twice anymore. Also
1248 Sequences cannot be added twice anymore to a dataset.
1249
1250 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1251 It gave wrong results by 1./2pi
1252
1253 - showplot: got a new option to start a root interpreter, too
1254
1255 - mars: now displays a rough estimate of Disp and the third moment
1256
1257 - mars: now displays the event time MTime if available
1258
1259 - mars: show muon parameters graphically
1260
1261 - mars: now the file to open can be given as commandline
1262 argument
1263
1264 - merpp: Added support for new arehucas version >= 200507190
1265 implementing values for three temperature sensors in the
1266 counting house (MCameraAUX) and the name of the HV settings file
1267 (MCameraHV).
1268
1269 - merrp: Also fixed some problems with wrong versions numbers stated
1270 by arehucas and implemented some fixed for old versions (<200407070)
1271
1272 - callisto: MCalibrationHiLoCam can now be printed from its context
1273 menu, eg in the TBrowser
1274
1275 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1276 - 1.39 (MExtractTimeAndChargeSpline)
1277 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1278 This is important mainly for timing studies.
1279
1280 - callisto: Changed limits in MHCalibrationChargeCalc from
1281 - -100.125 to -98 (fgChargeHiGainFirst)
1282 - 1899.875 to 1902. (fgChargeHiGainLast)
1283 - -100.25 to -99 (fgChargeLoGainFirst)
1284 - 899.75 to 901. (fgChargeLoGainLast)
1285 Introduced new limits:
1286 - fgNumLoGainBlackoutLimit: 0.05
1287 - fgLoGainBlackoutLimit: 3.5
1288 - fgLoGainPickupLimit: 3.5
1289
1290 - callisto: The handling of automatic weights for the digital filter
1291 has been improved. There are now new calibration weights special
1292 for Monte Carlo calibrations.
1293
1294 - callisto: Updated Muon scale with latest results (1% difference
1295 for most data, 5% for Mar/Apr'05)
1296
1297 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1298 was saturated and the blackout-events in the low-gain exceed the
1299 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1300 This excludes those pixels which have a saturating high-gain
1301 channel, but the low-gain switch does not switch often enough
1302 to make the distribution reliable.
1303
1304 - callisto: fix a bug counting the number of saturated events. Up to now,
1305 the number of saturated slices was counted (which is one for a not too
1306 high number), but for some (pathological) pixels, many more slices
1307 saturated and produced wrong limits.
1308
1309 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1310 + MCalibrationRelTimeCam.CheckFitResults: Yes
1311 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1312 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1313 + MCalibrationRelTimeCam.CheckOscillations: Yes
1314
1315 - callisto: introduce max. number of events for intercalibration,
1316 the rest gets skipped. Default: 4096
1317 The calibration causes too many un-reliable pixels if more
1318 than about 5000 events are treated (@500 Hz) because of the
1319 mode hopping of the VCSels. However, in the past, some
1320 calibration runs have been taken (erroneously) with more
1321 than 5000 events, especially the intensity scans where
1322 a good precision is needed.
1323
1324 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1325 photo-electrons for the spline extractor by 1-2% (correctly).
1326
1327 - callisto: The intercalibration is now done using a full f-factor
1328 method instead of a simple update. This makes things slower but
1329 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1330 changes.
1331
1332 - callisto: MPedestalY3 now uses the same extraction range as the data
1333 as calculated by MPedestalY2
1334
1335 - callisto: A check of the fraction of allowed unsuitable (10%) and
1336 unreliable (30%) pixels has been addded when the conversion is
1337 calculated from interleaved events
1338
1339 - star: fixed a bug which caused MEffectiveOnTime containers not to
1340 be written. In the worst case they were skipped almost all, in the
1341 best case they were all ok. It depends on how often the new value
1342 was assigned just with an event which was skipped later by another
1343 task
1344
1345 - star: new histograms MHPointing and MHRate
1346
1347 - star: New tab (Currents) displaying the time evolution of the mean
1348 DC currents
1349
1350 - star: New tab (MeanRms) displaying the time volution of the mean
1351 Pedestal Rms
1352
1353 - star: Output now contains MReportStarguider
1354
1355 - star: Improved muon analysis. Due to the absense of a constant
1356 for the gaus fit for arc width and the fact that the arcwidth
1357 plot was a histogram instead of a profile the resulting psf
1358 became pedestal rms dependant
1359
1360 - ganymed: added new plot (MHPhi) for wobble mode as described in
1361 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1362
1363 - ganymed: corrects now (correctly?) for the misspointing in
1364 May/April 05
1365
1366 - ganymed: Two new default templates for ganymed.rc are avilable:
1367 ganymed_onoff.rc and ganymed_wobble.rc
1368
1369 - ganymed: The first version of MFMagicCuts has been released
1370
1371 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1372
1373 - ganymed, sponde: There are two new options to determin the number
1374 of bins for the signal region (NumBinsSignal) and the number of
1375 total bins (NumBinsTotal) in the MHThetaSq histogram
1376
1377 - ganymed: optimized palettes for MHDisp
1378
1379 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1380 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1381 sqrt(2) to large
1382
1383 - ganymed: The false source plot (MHDisp) is now based on Disp
1384 and a background model determined in the first loop is
1385 subtracted
1386
1387 - ganymed: MFMagicCuts are now available in the cvs. The correct
1388 solution for the disp ambiguity problem is now calculated using
1389 the third moment. The third moment cut therefor is skipped.
1390
1391 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1392 already determined by the third moment along the major axis and
1393 so its actual sign is aligned along the major axis of the shower.
1394
1395 - ganymed: If starguider data is available it is taken into account
1396 when calculating the source position. This is especially important
1397 for wobble data at high zenith angles and culmination data.
1398
1399 - ganymed: If available the starguider data is taken into account as
1400 good as it is possible without a starguider calibration. To switch
1401 it off add
1402 MPointingDevCalc.MaxAbsDev: -1
1403 to your ganymed.rc
1404
1405 - sponde: the zenith angle distribution is now weighted instead of
1406 choosen by default. This gurantees higher statistics in the highest
1407 and lowest energy bins. To switch this behaviour off use...
1408
1409 - sponde: now automatically displays the energy threshold
1410
1411
1412
1413 *** Version 0.9.3 (2005/06/03)
1414
1415 - general: MMcEvt now derived from MMcEvtBasic which should
1416 have no influence on compatibility with older camera files
1417
1418 - general: Implemented a new option to MReadReports which allows
1419 to force reading of the first event of some trees (eg. Drive-tree)
1420 before any other tree.
1421
1422 - general: Made a fix to MPointingPosCalc which assumes that the
1423 run-type is real-data if Process is called before ReInit, such
1424 that also the very first Drive-events in a run are treated
1425 correctly.
1426
1427 - shoplot now displays the filename in the title bar of the window
1428
1429 - merpp: new options: --auto-time-start --auto-time-stop which
1430 allow to cut updating with slow-control at the start- or
1431 (previousle --auto-time only allowed: and) stop-time of
1432 the run stored in the runheader.
1433
1434 - callisto: changed default of fgFallTimeHiGain in
1435 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1436 already set as default in callisto_Dec04Jan05.rc
1437
1438 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1439 now changes the filename for new weights automatically for
1440 cosmics, MC and for different calibration colors.
1441
1442 - callisto: a problem with the order of some code cause the
1443 name of the weights file in MPedestalY2 to be ignored.
1444 Wrongly the calibration_UV weights were used instead
1445 of the cosmics weights set in callisto.rc.
1446
1447 - callisto: should allow ct1 pulser data when the color is
1448 explicitly set also for pretty new runs
1449
1450 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1451 to introduce an additional scale factor (should be around 1)
1452 to adapt for slight deviations in different extractors from
1453 the MC calibration. For MC calibrations the scale factor
1454 is fixed to 1
1455
1456 - callisto: MFCosmics should handle very high signals a bit
1457 more accurate now
1458
1459 - callisto: when calculating the mean pedestal rms for different
1460 pixel sizes or sectors also kUnsuitableEvt is now taken into
1461 account - not only kUnsuitableRun
1462
1463 - callisto: '-raw' option is now the default
1464
1465 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1466 This has the advantage that mean values in the calibration (eg
1467 arrival times) are calculated more accuratly.
1468
1469 - callisto: In the resource file callisto_Dec04Jan05.rc
1470 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1471
1472 - callisto: new Hi-/Lo-Gain intercalibration constants
1473 hilocalib_sp1.root and hilocalib_sp1_mc.root
1474
1475 - callisto: changed default for MJPedestalY2.MaxEvents
1476 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1477
1478 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1479 has changed from 9.0 to 6.0. This is necessary to exclude two very
1480 ringing pixels in September which - when kept - destroy the image
1481 cleaning around them (Markus G.)
1482
1483 - callisto: (!) The Muon analysis of all data taken so far has
1484 suggested that different extractors give slightly different
1485 absolute results after calibration, due to there different
1486 handling of the calibration- and cosmics pulse shape. Although
1487 the over all calibration seems to be a bit to pesimistic (or
1488 the MC seems to be a little bit - 3-5% - too much attenuated).
1489 There for correction factors have been introduced which correct
1490 the calibration constants by
1491 0.956937799 for Digital Filter (callisto.rc)
1492 and
1493 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1494 calibration. The main advantage is, that both data types can
1495 be easily analysed together and compared to the same MC sample.
1496 The factors are choosen such, that the reference is now a
1497 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1498
1499 - star: fixed a bug which caused the first bin of the histograms
1500 vs time to disapear in PostProcess. This gave wrong results
1501 on the screen. The output and all following programs not
1502 directly accessing the histograms haven't been affected
1503
1504 - star, ganymed: Made sure that always the first Drive-tree event
1505 is read and Processed before the first data event was read.
1506
1507 - ganymed: implemented the possibility to replace the standard
1508 false source plot with a different one. For example: If
1509 you want to use a Disp based FS plot use the resource:
1510 NameHistFS: MHDisp
1511 For details about the requirements of these plots look
1512 at the corresponding classes
1513
1514 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1515 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1516 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1517 case MAlphaFitter is setup correctly. For On-Only optimization
1518 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1519 RunOn() instead of Run(). For energy estimation MJOptimize
1520 has been replaced by MJOptimizeEnergy
1521
1522 - sponde: The input MC spectrum can now be weighted to fake a
1523 different spectrum. This is done via MMcSpectrumWeight. For
1524 more details see the class description and sponde.rc
1525
1526 - sponde: The paremeter comparsion plots are not scaled by
1527 their entries anymore. Instead the MC plot is scaled by using
1528 the result spectrum of the analysis. If the input MC spectrum
1529 and the result spectrum has different slopes the absolut
1530 normalization is normally wrong.
1531
1532
1533
1534 *** Version 0.9.2 (2005/05/20)
1535
1536 - general: Changed the default paths for calibrated data and image
1537 files. (The implemented access to these files doesn't yet exist)
1538
1539 - general: support for MRunIter has been removed from the job classes
1540 (use the setter functions of MSeqeunce instead)
1541
1542 - general: ProcessFile has been renamed to Process in all job classes,
1543 because ProcessFile is missleading
1544
1545 - general: The storage of the palette in MHCamera is now possible
1546
1547 - general: new bits describing unsuitable and unreliable pixels have
1548 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1549 kDeadPedestalRms, kFluctuatingArrivalTimes
1550
1551 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1552 versions newer than V200404070
1553
1554 - general: support for cc file versions newer than V200504130. Added
1555 support for active loads (MCameraActiveLoad) and central pixel
1556 (MCameraCentralPixel)
1557
1558 - general: added new histograms for image parameters versus size
1559 (MHVsSize)
1560
1561 - general: The eventloop now automatically calls PrintStatistics
1562
1563 - Status Display: Improved support for printing:
1564 + A default can now be set in .rootrc (for more details see
1565 MStatusDisplay::PrintPS)
1566 + A print dialog is opened so that printer and command line
1567 can be canged
1568
1569 - showlog: improved such that it handles different verbosity levels
1570 more accurate now. This mean you can suppress output when
1571 using showlog.
1572
1573 - showplot: improved
1574 + The new graphics formats have been implemented
1575 (pdf, svg, png, jpg and xpm)
1576 + Implemented an interface for printing. Because you can change
1577 the printing command from the command line you can use all
1578 the nice postscript tool. To print a booklet for example call:
1579 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1580 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1581 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1582
1583 - callisto: fixed a bug in the recognition of the calibration bit
1584 pattern. Concerns only intensity calibration. (The strength of the
1585 intensity has been updated in some cases)
1586
1587 - callisto: add a filter against PIN Diode events when running over
1588 calibration runs since some of the recent calibration runs have
1589 been taken with Pin Diode.
1590
1591 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1592 39943, 44833 in the calibration (MCalibColorSet)
1593
1594 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1595 been set to 1e-18 in callisto_Dec04_Jan05.rc
1596
1597 - callisto: in callisto_Dec04Jan05.rc: set value for
1598 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1599 statistics for the calculation of the mean pulse time
1600 of the cosmisc
1601
1602 - callisto: the charge limit in the calibration has been raised
1603 from 2.5 to 4.5
1604
1605 - callisto: new setup read from callisto.rc
1606 + MCalibCalcFromPast.fNumEventsDump
1607 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1608 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1609
1610 - callisto: MExtractTimeAndChargeSpline extractor:
1611 + The integration ranges were shifted by 0.2 FADC slices to the right.
1612 + unreliable handling of floating point values caused different
1613 results on different platform or with different compiler options:
1614 The new algorithm is numerically exact and more accurate because
1615 it doesn't calculate the integration position by multiple times
1616 adding the step-size (which results in numerical uncertanties
1617 exspecially if multiplied with large numbers)
1618 + A lot of fixes have been introduced which effects integrating the
1619 spline at the edges of the valid range. In this case any memory
1620 was randomly accessed. This behaviour can be tested replacing
1621 all MArrayF by TArrayF which perform a range check (but of course
1622 they are a lot slower)
1623 ! No result obtained with the Spline before can be trusted! Due to
1624 random memory access it might by completely random!
1625
1626 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1627 + extraction range in the high gain to 4.
1628 + weights file to cosmics_weights46.dat
1629
1630 - callisto:
1631 + introduce the check for fluctuating arrival times.
1632 + set charge limit to from 2.5 to 4.5
1633 + introduce asymmetric exclusion due to "deviating number of phes":
1634 Default: -9.0 +4.5
1635 + make deviating number of phes unsuitable (see David's findings).
1636
1637 - callisto: fixed the display of unsuitable pixels. The old change
1638 to a real profile in MHCamera broke it.
1639
1640 - callisto: The cosmics filter is used in MJCalibration now
1641 independant of the pulser color (formaly it was used only for
1642 CT1-pulser data). The threshold of number of max empty pixels
1643 has been raised from 2% to 5% in MJCalibration. The maximum
1644 fraction of rejected event is 50% otherwise the calibration has
1645 failed. The filter now ignores unsuitable pixels.
1646 Setup the filter from callisto.rc using "ContCosmics"
1647 (see MFCosmics::ReadEnv)
1648
1649 - callisto: changed default for fgOffsetFromLogain back
1650 from -2.8 to -1.8 in digital filter.
1651
1652 - callisto: for the common extractors
1653 + MExtractFixedWindow
1654 * MExtractTimeAndChargeSlidingWindow
1655 * MExtractTimeAndChargeSpline
1656 * MExtractTimeAndChargeDigitalFilter
1657 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1658 and fResolutionPerPheLoGain
1659
1660 - callisto: Updated the hi-/lo-gain intercalibration constants
1661 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1662 hilocalib_df6.root
1663
1664 - callisto: The default lo-gain extraction window for the
1665 MExtractTimeAndChargeSlidingWindow extractor has been increased
1666 from 6 to 8 to take the stretch of the pusle into account
1667
1668 - callisto (!!!): fixed an important bug in the setting of the
1669 incoming pedestal pointer to the signal extractor extracting
1670 pedestals. This bug caused the pedestals not to be subtracted
1671 correctly in the calibration afterwards. The effect was about 10%
1672 too high conversion factors for the digital filter and the spline
1673 and more than 40% for the sliding window.
1674 The bug existed since end of February! (Markus G.)
1675
1676 - star: added muon support to star. A new tab "MHMuonPar" is
1677 displayed. The lower right plot is an estimate of the point spread
1678 function. A reference value is displayed. To get the real PSF
1679 you must compare with MC. The setup for the muon analysis
1680 is done in star.rc. More informations can be found in
1681 MHSingleMuon and MHCalibParCalc
1682
1683 - star: The weather data is now displayed in star
1684
1685 - star: MEventRateCalc handles the calculation of the event rate more
1686 accurate now in case of the start of a new run inside a sequence
1687
1688 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1689 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1690 changed only minimally
1691
1692 - ganymed: (MJCut and MJOptimize) now displayes the number of
1693 excess events versus size. The energy estimation is done in
1694 MJSpectrum (sponde)
1695
1696 - ganymed: got support for using other variables than Alpha, eg. Theta.
1697 Therefor you need a class deriving from MHAlpha which supports
1698 this variable (one is already existing: MHTheta, which is now the
1699 default in ganymed). It is setup through ganymed.rc
1700
1701 - added a full featured spectrum program (sponde) which reads
1702 ganymed output and monte carlos and compiles a spectrum
1703
1704
1705
1706 *** Version 0.9.1 (2005/04/14)
1707
1708 - Fix bug on the arrival time reconstruction when using Digital
1709 Filter (in some marginal cases (10%) times were reconstructed shifted
1710 by 0.2 slices)
1711
1712 - all executables now return 2 where in previous versions -1 has
1713 been returned (gave problems with shell-scripts)
1714
1715 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1716 also done with a intercalibration input file
1717
1718 - a bug in the time fine adjustment of the digital filter has been fixed
1719
1720 - a lot of small fixes to calling TPad::Divide with a margin==0
1721
1722 - MStatusDisplay now shows the memory usage
1723
1724 - added a memory leak statistic after the eventloop
1725
1726 - MHadronness replaced by MParameterD
1727
1728 - MEnergyEst replaced by MParameterD
1729
1730 - wobble mode can now be switched on from the data-set
1731
1732 - switched on bad pixel detection for a pedestal level
1733 which is more than 5 times the variance
1734
1735 - Fixed default paths to be correct for the new data center
1736
1737 - Fixed handling of drive data. The pointing position in now
1738 copied to MPointingPos inside star for real and MC events
1739
1740 - made sure, that the sequences in a dataset are sorted by
1741 their number to ensure the correct synchronization
1742
1743 - added all resource files necessary to handle spline extraction
1744 of signal for the late 2004 and the early 2005 data
1745
1746 - update the reference lines for the december data
1747
1748 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1749 This is important for the Dec. and Jan. data where the calibration
1750 pulse position changes much.
1751
1752 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1753 filter. This corrects only an defective extraction of the MC at
1754 low-gain signals lower than 90 phes.
1755
1756 - fixed some slowdown in calibrating data with interleaved events from
1757 Jan and Dec. As a workaround made the pretty palette the default.
1758 The inverse Deep Blue Sea has a bug which slows down long calibration
1759 runs a lot.
1760
1761 - implemented new values from new starguider report as defined
1762 in TDAS00-07 V7.1 (eg SkyBrighness)
1763
1764 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1765 in starguider report (If you merpp the same reports with this version
1766 you'll get the correct units (arcmin) but a different result
1767 than with old versions (wrong units))
1768
1769 - Now the status display can also write PNG, JPEG and XPM (other file
1770 formats are still unsupported by root)
1771
1772 - added a lot of scripts and macros in directory datacenter used
1773 for automatic processing
1774
1775
1776
1777 *** Version 0.9 (2005/03/23)
1778
1779 - Calibration is now done autmatically into photo-electrons like
1780 decided by the Collaboration Board
1781
1782 - Reference lines in the display can be read from resource file
1783
1784 - Interlaced calibration events can be handled by callisto
1785
1786 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1787 and applied in callisto.
1788
1789 - class MJCalibTest can be called by callisto
1790
1791 - callisto can now run with three data types: rawdata, rootdata, MC
1792
1793 - added two classes mreport/MReportStarguider.cc and
1794 mreport/MReportStarguider.h for implementing starguider-data
1795
1796 - the output of merpp-update now contains starguider information:
1797 MReportStarguider and MTimeStarguider
1798
1799 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1800 values were lower than they should. This was more visible for high
1801 energy (Size) events.
1802
1803 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1804
1805 - added a new loop to callisto to support the correct extraction of
1806 the pedestal and pedestal rms through the signal extractor
1807
1808 - added class to perform fourier tranformation of a hexagonal structure
1809 (MHexagonalFT)
1810
1811 - added class to perform fourier tranformation of a hexagonal structure
1812 in a tasklist (MHexagonalFTCalc) example: hft.C
1813
1814 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1815 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1816 small pixels, example: extendcam.C
1817
1818 - added possibility to write data to memory (TTree) using MWriteRootFile
1819
1820 - added possibility to read a TTree stored only in memory by MReadTree
1821
1822 - new classes to deal with the interleaved calibration events:
1823 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1824
1825 - implemented filters to callisto to skip calibration events
1826
1827 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1828 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1829 the slices by statistics
1830 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1831 signal extractor without randomization
1832 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1833 with the signal extractor with randomization (extraction window is
1834 randomly fixed)
1835 The three kind of pedestal is not yet implemented (for speed reasons) as
1836 long as nobody really needs it:
1837 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1838 extracted with the signal extractor with randomization
1839
1840 - callisto now finds the pulse position in the data automatically
1841
1842 - implemented data reduction in calibrated data by reducing the precision
1843 of the stored floating point values (pedestal, rms and signal) to
1844 roughly 0.5%
1845
1846 - fixed showplot to make file format conversion (eg. converting a
1847 status display stored in a root file into a postscript file) in
1848 batch mode possible:
1849 showplot -b --save-as-ps[=outfile.ps] infile.root
1850
1851 - Allow class names as part of filter rules, eg
1852 (MFSupercuts) && (MHillas.fSize>100)
1853
1854 - fixed a lot of stuff to allow all programs to process MonteCarlo
1855 camera files.
1856
1857 - enhanced possibility to debug reading of resource file
1858
1859 - MDataChain should handle priorities of operator more
1860 accurate now
1861
1862 - completely revised the container in which the signal is stored
1863 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1864 * the new implementation is faster and
1865 * needs less storage space
1866
1867 - FIRST version which can process Monte Carlos through the
1868 whole chain of programs (callisto, star, etc)
1869
1870 - implemented new image parameters for the border length of
1871 the shower image (MNewImagePar2)
1872
1873 - implemented wobble-mode in ganymed
1874
1875 - new class (MJOptimize) taking care of all optimization processes
1876
1877
1878
1879 *** Version 0.8.6 (2004/10/05)
1880
1881 - New combined signal and time extractor
1882 MExtractTimeAndChargeDigitalFilter
1883
1884 - The Report for the trigger section in the CC run summary has been
1885 updated, and now the IPRs (Individual Pixel Rates) are available.
1886
1887 - new macros for database interaction: filldotrun.C, filldotrbk.C
1888
1889 - added new program which can convert colored output which was redirected
1890 into a file back into colored text (for example to display it with
1891 more): showlog
1892
1893 - added new program to display an MStatusArray of plots (stored with
1894 MStatusDisplay) from a file: showplot
1895
1896 - Added support for Sequences (MSequence). Sequences are blocks of run
1897 files containing the same calibration and belonging to the same
1898 source
1899
1900 - Added a new task (MTaskEnv) which can be used in setup files to switch
1901 between different tasks (for example to choose a signal extractor)
1902
1903 - Implemented automatic file splitting in MWriteRootFile
1904
1905 - After image cleaning an island index is assigned to all used pixels.
1906 The index corresponds to the order of the islands in size.
1907
1908 - added a cleaning which takes signal height _and_ arrival time into
1909 account: probability cleaning (for more details see MImgCleanStd)
1910
1911 - added a cleaning which takes takes the absolute number of photons
1912 times the area ratio as cleaning level
1913 (for more details see MImgCleanStd)
1914
1915 - Changed calculation of image parameters such, that it can be done
1916 for all used pixels or the pixels with a defined island index only
1917
1918 - implemented new image parameters displaying the number of islands,
1919 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1920
1921 - event display in executable changed to support also calibrated files
1922 (done with MJCalibrateSignal)
1923
1924 - added program doing the calibration and the signal extraction
1925 and signal calibration: callisto Most part of the setup is done
1926 by a resource file: callisto.rc
1927
1928 - implemented support for pixels with negative IDs (Raw file format
1929 version 4)
1930
1931 - implemented an new option in merpp (--auto-time) to get the time
1932 range for cc and/or caco data from the run header of the raw data
1933
1934 - New star-program (star and MJStar). Taking calibrated data from
1935 callisto/MJCalibrateSignal as input. The setup is done through
1936 a resource file: star.rc
1937
1938 - Added possibility to setup the eventloop in the mars-executable
1939 Camera Display by a resource file: mars.rc
1940
1941 - The the mars-executable Camera Display can now also read
1942 calibrated data files written by callisto/MJCalibrateSignal
1943
1944 - Added a new class which can calculate the source position in
1945 the camera from a pointing model known to be correct and
1946 the pointing model used for observations (MSrcPosFromModel)
1947
1948 - added a new version of the class calculating the effective on-time
1949 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1950 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1951 MHTimeDiffTheta.
1952
1953 - added the possibility to count how often a signal is above (or
1954 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1955 can replace MHTriggerLvl0)
1956
1957 - added ore convinient ways to set the axis-titles of your histograms
1958 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1959 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1960
1961
1962
1963 *** Version 0.8.5 (2004/08/06)
1964
1965 - new Signal Extractors: MExtractFixedWindowSpline
1966 and MExtractAmplitudeSpline
1967
1968 - implementes interleave in merpp to be able to merpp parts of a file
1969
1970 - implemented force-functionality to merpp
1971
1972 - star display to display star catalogs (MAstroCatalog)
1973
1974 - star display to 'mirror' stars to the camera (MAstroCamera)
1975
1976 - implemented a new cleaning option which allows cleaning scaled with
1977 the real ratio of the rms depending on the pixel size, not only the
1978 square root of the pixelsize (MImgCleanStd, MCameraData)
1979
1980 - removed obsolete MBlind* classes
1981
1982 - Signal extractor taking the AB flag into account implemented (this makes
1983 an odd number of slices for signal extraction possible
1984 (MExtractSignalABcorr)
1985
1986 - implemented a class extracting the pedestal from the raw-data (events)
1987 itself using empty lo-gain (MpedCalcFromLoGain)
1988
1989 - Added mean values to MPedPhotCam
1990
1991 - Added Makefile for Darwin (this OS is NOT officially supported!)
1992
1993
1994
1995 *** Version 0.8.4 (2004/04/19)
1996
1997 - new fast arrival time extractor using cubic splines:
1998 MExtractTimeFastSpline
1999
2000 - implementes multi-argument support in MDataChain
2001 ("pow(a, b)")
2002
2003 - implemented double reference support in MDataChain
2004 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2005
2006 - added support in MF for expressiond like
2007 "MHillas.fWidth<2*<MHillas.fLength"
2008
2009 - MDataChain is now able to support variables like [0], [1], ...
2010 which can be used in fit functions as parameters. The interface
2011 is implemented through the new virtual function
2012 MParContainer::SetVariables
2013
2014 - added new class MArrivalTimeCam/MArrivalTimePix:
2015 Storage containers to hold the ArrivalTime of the camera/pixel
2016
2017 - added new classes for the calibration of relative arrival times:
2018 MCalibrationRelTimePix and MCalibrationRelTimeCam
2019
2020 - added new classes to extract the signal of the blind pixel and the
2021 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2022
2023 - added new classes for the bad-pixels treatment (MBadPixels*)
2024 which are more powerfull than the old ones (MBlindPixel*)
2025 and will replace them.
2026
2027 - added filter against cosmics: MFCosmics
2028
2029 - added new class MArrivalTimeCalc2:
2030 Calculates the arrival time as the signal weighted mean of the time
2031 slices in the maximum window
2032
2033 - added a new macro call pointspreadfucntion.C that fits with a 2D
2034 gaussian the DC spot for an star. It gives you the RMS of
2035 the PSF and the center of the star, very useful for misspointing
2036 studies.
2037
2038 - added support for multi-telescope camera files. Added classes
2039 MStereoCalc and MStereoPar, classes to calculate and store shower
2040 parameters calculated from the data of two telescopes, for the MC
2041 studies regarding the MAGIC clone.
2042
2043 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2044 MC data calibrated in photons instead of ADC counts.
2045
2046 - added three macros to show the calibration and analysis chain of
2047 MC data. The macro starmc.C does both calibration and analysis, producing
2048 an output containing Hillas parameters for each event. The macro
2049 mccalibrate.C does just the calibration and writes out a file containing
2050 pixel information in photons instead of FADC data. The macro starmc2.C
2051 reads in such a file and produces an output with Hillas parameters.
2052
2053 - added MPedPhotCalc to compute pedestals in units of photons, see
2054 macro pedphotcalc.C
2055
2056 - added all class to perform the calibration, see macro calibration.C
2057
2058 - added class MFFT to perform Fast Fourier Transforms
2059
2060 - added class MSimulatedAnnealing to perform simulated annealing
2061 minimizations
2062
2063 - added new macro bootcampstandardanalysis.C which holds the skeleton
2064 of the analysis chain discussed in the december bootcamp.
2065
2066 - added support for DAQ raw data file format V2
2067
2068 - implemented an arbitrary time stamp for the events from raw-data
2069 files with file version<3. It is calculated from the run number,
2070 the date of start and the FADC clock tick from the first module
2071
2072 - implemented the correct decoding of the event time-stamp
2073 coming from the DAQ for raw-data files with file-version>2
2074
2075 - added a new classes storing the pedestals in units of photons:
2076 MPedPhotPix, MPedPhotCam
2077
2078 - added support for DC current files from the camera control
2079
2080 - added support for start- and stop-time when merpping report files
2081
2082 - added MReportCC storing the weather data from the CC-REPORT
2083
2084 - added class to fill trainings and test matrices (MTFillMatrix)
2085
2086 - added a filter performing a software trigger (MFSoftwareTrigger)
2087
2088 - Added classes to perform parts of the standard analysis (Jobs):
2089 + MJPedestals
2090 + MJCalibration
2091 + MJExtractSignal
2092 Note: All of them are preliminary!
2093
2094 - Added Iterator to iterate over files giving only the run-number
2095
2096 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2097 the evolution of a sector vs time
2098
2099
2100
2101 *** Version 0.8.3 (2003/12/05)
2102
2103 - adapted Random Forest classes to allow the use with MC
2104 multi-telescope files which can be produced with the coming
2105 camera version 0.7.
2106
2107 - added classes to read and interprete central control report files
2108 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2109
2110 - enhanced merpp (the executable) to support .raw and .rep files.
2111
2112 - added classes for light calibration (MCalibration* and
2113 MHCalibration*) by Markus Gaug. Further work has to be and will
2114 be done soon.
2115
2116 - Added a preliminary 'synchronizer' (MReadReports) which will
2117 replace MReadMarsFile as soon as it is finished.
2118
2119 - Added a tutorial macro demonstrating how report files are merpped
2120 and how they can be read from the root file in the correct order
2121 of time (readrep.C)
2122
2123 - Added a generalized histogram (similar to MH3) called MVsTime
2124 which allows to plot variables (or rules - MDataChain - of
2125 variables) vs time. For an example have a look at tempvstime.C.
2126
2127 - Changed the name of the event trees:
2128 + Events --> Events
2129 + PedEvents --> Pedestals
2130 + CalEvents --> Calibration
2131
2132 - changed name of MTime in the event trees from MRawEvtTime to MTime
2133
2134 - added displaying the sector indices to the mars event display
2135
2136 - Magic Online Analysis (MOnA) implemented in a first version
2137 (see mona.cc, MOnlineDump and MOnlineDisplay)
2138
2139 - added classes to calculate event rate
2140 (preliminary: MEventRateCalc, MEventRate)
2141
2142 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2143
2144 - added classes dealing with the telescope pointing position (MPointing*)
2145
2146 - implemented the 'final' Mars time stamp based on some experiences with
2147 the new 'Synchonizer'
2148
2149
2150
2151 *** Version 0.8.2 (2003/11/10)
2152
2153 - accelerated standard analysis by a factor of 6-8 ...
2154 + doing precalculations in MGeomCam for the pixel area ratio
2155 + creating a look up table for the single pixels in MCerPhotEvt
2156
2157 - added task to calculates weights in case you want to 'change'
2158 the energy spectrum of a monte carlo file
2159 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2160
2161 - added a new executable star which implements the
2162 star.C macro as precompiled executable. Currently a flexible
2163 setup is not possible, but a 'input card' setup will follow.
2164
2165 - Starting to implement Multi-Telescope-Support based on the
2166 upcomming camera version 0.7. The base for a general support
2167 is implemented and the star-functionality is proven to work.
2168
2169 - Replaced Event-Display in and Camera-Display in the Mars GUI
2170 executable by a more convinient display base on MStatusDisplay.
2171
2172 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2173
2174
2175
2176 *** Version 0.8.1 (2003/10/20)
2177
2178 - added signal subtraction for pure on data by means of fitting
2179 the background in the off region or by performing a combined
2180 signal/background fit. Provides necessary histograms for
2181 obtaining energy spectra and a light curve.
2182
2183 - added classes to perform and study the selection of the
2184 2nd Level Trigger on MC data (example in triglvl2.C macro)
2185
2186 - added pedestal calculation
2187
2188 - implemented "democratic cleaning" (tail cut value proportional
2189 to pixel area) according to Wolfgang's suggestion.
2190
2191 - added Sigmabar treatment (calculation and basic histogramming)
2192
2193 - added basic routines to apply padding
2194
2195 - added first implementation of MARS-based source visibility plotter
2196 (needs to be linked against slalib, preliminary version)
2197
2198 - enhanced functionality of data chains: random numbers, conversion
2199 functions and access to MHMatrix objects
2200
2201 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2202 numbers under certain circumstances (runs with 0 events included)
2203
2204 - fixed a bug in the general filter MF (didn't work on some systems
2205 at all)
2206
2207 - fixed a bug in chaining files, which caused the analysis to crash or
2208 ignore files
2209
2210 - implemented more geometry classes describing the parameters used
2211 to simulate the PMT camera
2212
2213 - added new Monte Carlo classes containing the setup of the different
2214 programs in the MC chain.
2215
2216 - added a (preliminary) general task to evaluate chi-square of a given
2217 parameter in an eventloop.
2218
2219 - first implementation of a container describing the observatory
2220 location (Long, Lat, etc)
2221
2222 - added Random Forest - method for g/h-separation
2223
2224 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2225 (this means, that it is compiling, but not yet fully tested)
2226
2227 - added a new status display which can show the present status
2228 of histograms while an eventloop is running (MStatusDisplay,
2229 an example can be found at status.C)
2230
2231 - reorganized directories:
2232 classes describing the image --> mimage
2233 classes containing Monte Carlo Histograms --> mhistmc
2234 classes for Random Forest method --> mranforest
2235
2236 - added (event-)weights to fill histograms
2237
2238 - colors in logging output to screen
2239
2240 - changes to the Image Parameter declaration:
2241 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2242 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2243 + MHillasExt now derives from MParContainer instead of MHillas
2244 --> Files written with the old definition are more or less unreadable
2245
2246 - reading of reflector files
2247
2248 - display data from reflector files in the camera
2249
2250 - implemented currents (and display them in the camera)
2251
2252 - logarithmic scale in camera
2253
2254 - added class to iterate through directory contents (MDirIter)
2255
2256
2257
2258 *** Version 0.8 (2002/11/18)
2259
2260 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2261
2262 - corrected 48(!) wrong entries in the Next Neighbor table of the
2263 Magic Camera (all in the inner part of the outer ring, mostly
2264 missing a single NN)
2265
2266 - Fixed a bug in the table describing the Next Neighbours of the
2267 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2268 have any neighbour)
2269
2270 - changed trigrate.C: now it calculates the pure NSB triggers from
2271 a camera file (generated with no showers), so there is no need
2272 to introduce them by hand in the BgR array (for more details
2273 please ask Abelardo)
2274
2275 - added MHHadronness (and MHadronness) as a general facility to evaluate
2276 the quality of a gamma-hadron seperation method
2277
2278 - changed MWriteAsciiFile to accept rules (MDataChain)
2279
2280 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2281 must be replaced by calles to MWriteAsciiFile::AddColumn and
2282 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2283 changed.
2284
2285 - Implemented generalized event-matrices (one row per event)
2286 (MHMatrix)
2287
2288 - implemented the one dimensional composite probabilities
2289 (MHCompProb, MCompProbCalc, comprob.C)
2290
2291 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2292 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2293
2294 - Added a camera display displaying the pixel numbers to the
2295 event display gui.
2296
2297 - Added Monte Carlo Informations to event display gui
2298
2299 - Changed the camera display to display the pixel numbering
2300
2301 - Added three buttons to the camera display to change the palette
2302
2303 - Added the number of used and core pixels after image cleaning
2304 to MHillas
2305
2306 - Changed the algorithm used in MHillas according to TDAS 02-03
2307
2308 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2309
2310 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2311
2312 - Added fCosDeltaAlpha to MHillasSrc
2313
2314 - The numbers of photons used to calculate fConc and fConc1 in
2315 MHillasExt are now scaled with the pixel size, so that one get
2316 a four times smaller value for the bigger pixels in the outer ring.
2317
2318 - added new task to smooth the camera contents (MCameraSmooth)
2319
2320 - added possibility to use interpolated pixel values for blind pixels
2321 instead of removing it completely from the analysis
2322
2323 - Implemented the possibility to save the whole eventloop with
2324 its setup to a file. This information can be read and from
2325 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2326 and MEvtLoop::MakeMacro. If you find something not working, please
2327 report - this stuff is still in a beta phase.
2328
2329 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2330 file having crab starfield, but also for all following files - fixed
2331
2332 - MTaskList::PrintStatistics can now be instructud to print also the
2333 title, too: use PrintStatistics(0, kTRUE)
2334
2335 - Changed the image cleaning so that pixels with to many 'used'
2336 neighbors are left used (to get rid of 'holes' in events)
2337
2338 - Introduced more output to the camera displays
2339
2340 - Added an array of histograms (eg one hist per run), MHArray
2341
2342 - Added a _preliminary_ version of the reader for CT1 PreProc files
2343 (MCT1ReadPreProc)
2344
2345 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2346 (thanks to Raquel)
2347
2348 - added the first energy estimator (MEnergyEstParam, estimate.C,
2349 estfit.C) using a parametrization
2350
2351 - Added some new Monte Carlo paremeter containers used to store
2352 setup information from the MC chain (MMcConfigRunHeader,
2353 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2354
2355
2356
2357 *** Version 0.7 (2002/04/30)
2358
2359 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2360 the pedestal mean value was saved incorrectly. For files from
2361 this versions we substract 0.5 from the pedestal mean.
2362 WARNING: This may effect your results, so don't wonder...
2363
2364 - First implementation of an algorithm using only triggered events
2365 for the collection area calculation
2366
2367 - Ascii Output can now also be used for parameter containers which
2368 doesn't overload MParCointainer::AsciiWrite
2369
2370 - The Ascii Output is now also capable of writing single data members
2371 of one container
2372
2373 - You are now able to change the order of the values written to the
2374 ascii file
2375
2376 - You can now specify a conversion factor for each data member written
2377 to an ascii file. This may be usefull to change the units of the
2378 data member (eg. degrees instead of millimeters in case of the
2379 hillas parameters)
2380
2381 - Replaced old MHillas by a new structure which allows you to extend
2382 the parameters stored in MHillas very easily:
2383 see MHillas and MHillasExt
2384
2385 - Added classes to handle source dependancy of image parameters:
2386 see MHillasSrc
2387
2388 - Added container (MBinning) to have a standard input for the binning
2389 in different histograms (eg. the Energy bins should be the same in
2390 all histograms)
2391
2392 - Changed Hillas histograms from mm to deg
2393
2394 - Added the flexible binning to the hillas histograms
2395
2396 - Added a filter for the alpha parameter (MFAlpha)
2397
2398 - It is now possible to write single data members of a class object to
2399 an output stream instead of the whole container only
2400
2401 - Added a generalized filter for a data member:
2402 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2403
2404 - Added a generalized Filter parser for more difficult filter rules
2405 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2406
2407 - Added new Monte Carlo histograms:
2408 MHMcEnergyImpact and MHMcEfficiency
2409
2410 - Added many new histograms needed for the flux calculation.
2411
2412 - Added a generalized histograms which can fill and show up to three
2413 data members in either a one-, two- or three-dimensional histogram, eg:
2414 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2415
2416 - Added:
2417 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2418 * calculation of <Theta> as a function of time (MHThetabarTime)
2419 they are needed in the flux calculation in
2420 order to select for a given bin in Theta (or time) the appropriate
2421 effective collection area, which is assumed to be given as a function
2422 of Theta and the true energy
2423
2424 - Added calculation of the migration matrix in the energy
2425 (MHMcEnergyMigration):
2426 the migration matrix describes the migration from the true (E_true)
2427 to the estimated energy (E_est); it is needed to determine the
2428 distribution of E_true from the measured distribution of E_est
2429 by unfolding
2430
2431 - changed the color palette in the camera display to DeapSea.
2432
2433
2434
2435 *** Version 0.6 (2002/01/15)
2436
2437 - Introduce the option of disable pixels (MBlindPixels and
2438 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2439 able to deal with Star Field NSB.
2440
2441 - Fixed a bug in the pedestals substraction
2442
2443 - Introduced verbosity levels
2444
2445 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2446
2447 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2448 work correctly (thanks to Abelardo)
2449
2450 - Introduced correct treatment of the diffuse Night Sky Background
2451 and NSB (MMcPedestalNSB)
2452
2453 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2454
2455 - Introduced MMcRunHeaders which contains monte carlo run informations
2456
2457 - Added a 'Print'-Task (MPrint) which calls the Print function
2458 of a parameter container for each event
2459
2460 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2461
2462 - changes to be more efficient with root 3.02/06
2463
2464 - root 3.02/06 fixes:
2465 + the memory leak when reading MRawEvtData
2466 + loosing more time than necessary to update the progress bar
2467
2468 - MWriteAsciiFile is now capable of writing more than one container
2469 in a line. For example: To be able to write Monte Carlo and
2470 Hillas values (energy and alpha) in one line.
2471
2472
2473
2474 *** Version 0.5 (2001/11/06)
2475
2476 - Added new GUI functionality (Analysis)
2477
2478 - Added a camera display to be able to display events in the camera
2479 together with the calculated hillas ellipse
2480
2481 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2482 object at any state of the analysis, so that the output are several
2483 states
2484
2485 - Fixed a bug in the collection area error calculation
2486 (Thanks to Ciro and Abelardo)
2487
2488 - Fixed a bug which causes merpp to crash in some environments
2489
2490 - Implemented auto enabling scheme for Branches to speed up reading
2491 a lot (see MReadTree and MTask)
2492
2493 - Fixed a bug in the Histogram classes which caused histograms to
2494 be written to a file by MWriteRootFile without request
2495
2496 - changed the object I/O from the old stylish root I/O to the new
2497 'auto evolution scheme' This was done only for classes which are not
2498 yet used in Monte Carlo files, so that these files are still readable.
2499
2500 - Added support for a progress bar in MEvtLoop and MReadTree
2501 (see the Analysis Window in Mars for an example)
2502
2503 - Fixed a bug in the package creation which disturbed the conversion
2504 between a mars version unpacked from a tar file and the repository.
2505
2506 - Changed the code to writer merpped (converted into root format)
2507 raw files, to get faster (around 10%)
2508
2509
2510
2511 *** Version 0.4 (2001/09/20)
2512
2513 - This release is made to compile on a root version >= 3.00
2514
2515 - Fixed a bug which causes MReadTree to read the first file only
2516
2517 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2518
2519 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2520
2521 - Added a task to write several container to a root file (MWriteRootFile)
2522
2523 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2524
2525 - Added calculation of the collection area (MMcCollectionAreaCalc)
2526
2527 - fixed some bugs in the Hillas calculation
2528
2529 - added filters to be able to control the task execution dependent on
2530 a parameter (for example: the number of level 1 triggers in a MC-file)
2531
2532
2533
2534 *** Version 0.3 (2001/04/23)
2535
2536 - Many demo macros added
2537
2538 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2539
2540 - Hillas Calculation added
2541
2542 - Standard image cleaning available
2543
2544 - MReadTree is now able to handle more than one file
2545 (Remark: of the same structure)
2546
2547 - Now we are able to display events in a first version of the
2548 Camera event display. To do this we must run the macro
2549 "macros/readCT1.C" to read data from CT1.
2550
2551
2552
2553 *** Version 0.2 (2001/01/24)
2554
2555 - First Implementation of a Gui to read the raw data. Start the
2556 gui with the command mars.
2557
2558
2559
2560 *** Version 0.1 (2000/12/20)
2561
2562 - First official release 0.1
2563
2564 - Changes:
2565
2566 + changed calling style of MRawPixelIterator from do...while to
2567 while-loop
Note: See TracBrowser for help on using the repository browser.