source: trunk/MagicSoft/Mars/NEWS@ 8679

Last change on this file since 8679 was 8679, checked in by tbretz, 18 years ago
*** empty log message ***
File size: 106.0 KB
Line 
1 -*-*- END -*-*-
2
3 *** <cvs>
4
5 - database: the position used for the pulse pos check was missing
6 in the callisto output and could thus not be filled into the DB.
7 Also the old values seemed not exactly the PulsePos used for
8 teh check.
9
10 - general: Now the output files (calib*.root, etc) also contain the
11 resource file (to check it open it in the TBrowser and choose Print()
12 from the context menu)
13
14 - general: Dataset files now allow to overwrite the default path
15 to search for sequence and data files. Note, that the program
16 option and individual resources will overwrite it. For example:
17 SequencePath: /magic/montecarlo/sequences
18 DataPath: /magic/montecarlo/star
19
20 - general: Fixed a problem with variables in MDataPhrase. It seems
21 that only optimdisp (didn't work) was effected.
22
23 - general: Some improvements to the optim and train processing. For
24 example the ststud window now got a proper title.
25
26 - general: The "Status Display: " was removed from the window title
27 within an Eventloop.
28
29 - merpp: Merpp can read file format version 9 now. Please realize
30 that for file format version 9 the extraction range is different
31 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
32 the first and last 15 slices have been removed from all MUX data.
33
34 - mars: Similar to writing movies you can now select events which
35 should be displayed in your display. Therefore add the following
36 lines to your mars.rc:
37 MFEvtNumber.FileName: ganymed00223552.root
38 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
39 The input file can be a ganymed-file after (ganymed*.root) or
40 before (ganymed*-summary.root) file. For example to select all events
41 from your on sample after cuts (excluding the ThetaSq cut) use
42 MFEvtNumber.Selector: DataType.fVal>0.5
43 To show all events from your on-sample after quality cuts
44 use the summary file instead.
45
46 - mars: new ways to call mars are implemented. Instead
47 of calling
48 mars filename.root
49 you can now also use
50 mars sequence.txt
51 or
52 mars sequence.txt inputpath
53 or replace sequence.txt by the sequence number if the default
54 sequence file should be used.
55
56 - mars: The default size has been increased
57
58 - mars: There are two new heckboxes which allow to switch off
59 the calculated image parameters
60
61 - callisto: was broken for MCs... fixed.
62
63 - callisto: improved calculation of spline coefficients a lot. This
64 leads to a further improvement of the event rate calibrating MUX
65 data of about 15% (175evt/s instead of 150evt/s)
66
67 - callisto: finally the raw data we read is now real 16bit (with
68 10bit precision) for MUX data and not a stripped 8bit number
69 anymore. Due to scaling of the numbers (without precision loss
70 into an [0-256[ range, the final numbers for pedestal, pedestalrms
71 and extacted signal don't change. However, at all places where
72 raw data is directly accessed (eg. saturation and variation
73 limits in the signal- and pedestal-extraction) the numbers
74 refer still to the data's 16bit range.
75
76 - callisto: The maximum arrival time difference used in the bad
77 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
78 for both, old FADC and MUX-FADC, data.
79
80 - callisto: Be aware that callisto is now calibrating the arrival time
81 in nanoseconds rather than time slices. Also all following tasks
82 have been changed to assume ns units now. If you star data
83 calibrated with an older version it might be necessary to adapt
84 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
85 to obtain optimal results. The plot in the PulsePos tab
86 will now be in ns, too. This might also mean that the Muon
87 analysis in star might not work as perfect as expected as long
88 as old files read in.
89
90 - star: For speed reasons events suitable for the muon analysis
91 are now also preselected by fConcCOG<0.1 which seems to be a very
92 good preselector for muons.
93
94 - star: is now calculating a new timing parameter the Slope along
95 the major and minor axis of the shower. Therefore a numerical
96 solution of a line-fit is used. To use MHillasExt.fSlopeLong
97 and MHillasExt.fSlopeTrans don't forget to multiply it with
98 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
99
100 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
101 have been removed from MNewImagePar. They have never been good for
102 anything.
103
104 - star: Implemented a new recursive algorithm which is supposed to be
105 faster. Also implemented new cleaning oiptions, which are:
106 + CleanLevel0:
107 The cleaning level above single core pixels can be kept
108 + KeepIsolatedPixels:
109 Define whether single core pixels should be kept
110 + TimeLevel1:
111 The coincidence window in nanoseconds to single used neighbors
112 + TimeLevel2:
113 The coincidence window in nanoseconds to two used neighbors
114 + PostCleanType:
115 MOde in which a time dependent post cleaning should be applied
116 0: No post cleaning
117 1: Require for each used pixels at least one used neighbor
118 within a time-window of CleanLevel1
119 2: Require for each used pixels at least two used neighbor
120 within a time-window of CleanLevel2
121 3: Require first two and second one used neighbor
122 within a time-window of CleanLevel1 and fCleanLevel2
123 respectively
124 + RecoverIsolatedPixels:
125 - recoveres isolated core pixels if they have a used neighbor
126
127 - mars/star: The new default cleaning is:
128 + CleanLevel1: 6.0
129 + CleanLevel2: 3.0
130 + CleanTime1: 1.75
131 + CleanTime2: 1.75
132 + PostCleanType: 3
133
134 - star/ganymed: The old spark-cuts have been replaced by new ones.
135 These new spark cuts have been cross checked with the sequences
136 84720 (before splitter), 101041 (after splitter) and 223539 (new
137 FADCs). In all cases they seperate pretty well, but of course not
138 perfect. Monte Carlos have suggested to tighten the cuts a little
139 bit further at low sizes. This has been done.
140
141 - ganymed: IMPORTANT - The spark cuts have been changed to match
142 all available data more or less well. This might mean that for
143 YOUR data there are still sparks visible.
144 Whenever you do an analysis you have to make sure that NO sparks
145 survive your cuts!
146
147 - ganymed: The old hadronness and size cuts have gotten new indices
148 (10, 11). The old indices 8 and 9 now mean an additional condition
149 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
150 If you want to switch off this cut just move the line far away enough,
151 e.g. by setting c[9] to -500. Please update your ganymed.rc files
152 accordingly!
153 The unit of c[9] is deg. It is the dist at which your cut will
154 cross the slope==0. The unit of the slope is ns/deg. So if
155 you readin files calibrated with an older Mars-version you
156 have to adapt the default value for c[9] to the FADCs:
157 - Multiply by two for the MUX FADCs (run number > 200.000)
158 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
159 - Multiply by 42 for the meaning of life (run number = 200.000)
160
161 - ganymed: The old Cut0 is now called CutQ and is calculated before
162 the source position is caluclated. If you need a quality cut
163 including source dependant data (be very carefull with this!)
164 you have to use Cut0 instead.
165
166 - ganymed: now properly supports three off regions in wobble mode.
167 It will be the default from now on in ganymed_wobble.rc. To change
168 the number of off-regions use
169 NumOffSourcePositions: 1
170 in your ganymed.rc. Also by default no off-theta cut will be done
171 anymore so that you will get a background level higher than the
172 signal level in your ThetaSq plot for ThetaSq>0.2.
173 Due to this be carefull changing the scaling mode away from
174 "None". You will underestimate your signal if your scale interval
175 is not properly set.
176 (Rem: ThetaSqN is no longer needed)
177
178 - ganymed: is now storing the events of all (on- and off-)
179 source positions even in the case of more than one off-source
180 position. This should allow sponde to work properly and the
181 energy estimation is done correctly in all cases (without any
182 "nearest position" trick)
183
184 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
185 with a real pointing model for the starguider is done, calibrated
186 with more than thousand tpoints taken from this date on.
187
188 - ganymed: was broken for Wobble-MCs... fixed.
189
190 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
191 has changed. Note that your old ganymed.rc will be incompatible
192 with the new algorithms! Please check the ganymed.rc files and
193 the class description of MFMagicCuts for more information.
194 It is recommended at the moment to use identical Disp-Parametrizations
195 for on/off- and wobble-mode. If cuts are optimized only
196 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
197 should be optimized. All other values should be kept as they are.
198 If you want to do an anylsis without timing a parameters, you can
199 switch off the timing cuts by seeting parameter 7 to a very small
200 value (eg. -99). To remove the slope parameter from the disp
201 paremtrization set parameter 8 to 0.
202
203 - ganymed: The distribution of observation time versus zenith
204 angle is now shown for off- AND on-data.
205
206 - optim, sponde: should now properly support three off-regions.
207 Just produce your ganymed summary files with three off-regions.
208 optim and sponde will automatically get all off events from
209 all off-regions from this file. Please do not forget to
210 set the scaling in optimwobble.C properly:
211 fit.SetScaleUser(1./3);
212 it is not yet read in automatically (will follow soon).
213 In the case of fixed Scale you can also use
214 cuts.SetThetaCut(MFMagicCuts::kOn);
215 no off-cut needed.
216 Be carefull in case of three off-regions when switching on
217 scale mode. Make sure that the scale interval is set correctly.
218
219 - sponde: In the estimated energy versus monte carlo energy plot the
220 contents where exchanged.... fixed.
221
222 - sponde: the so called "accurate"-mode has been removed. It didn't
223 give any improvement in accuracy, only decreased execution speed.
224
225 - sponde: now checks whether the theta distribution of your on-data
226 and the theta-distribution of your Monte Carlo sample (after
227 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
228 sample is incomplete) execution is stopped. Execution can be forced
229 using the new option --force-theta. Use this option with care!
230
231 - sponde: Proper collection areas can now be constructed also from
232 Monte Carlo samples generated with different maximum impact
233 parameters. Note that in previous version you neither got
234 a warning or failure, nor was there any obvious sign that the
235 collection area was overestimated due to usage of files with
236 different maximum impact parameters.
237
238 - sponde: the output file now contains more information about
239 the spectrum (eg. the full 2D collection area histogram).
240 Note, that this information can only be written to the file
241 if it is stored automatically via command line argument.
242 If you only store the status display from within the display
243 the information is lost.
244
245 - sponde: added a new tab "EventDist" showing the unweighted real
246 absolute number of events of your sample after cuts. This tells
247 you how many events with this energy you had in your MC files.
248 The same information you get from the error bars of the weighted
249 histograms, but this is less intuitive.
250
251
252
253 *** Version 1.2 (2007/05/14)
254
255 - database: The database now has two new values Unsuitable50 and
256 Unsuitable01. They express the number of pixels which are
257 unsuitable for more than 50%, respectively more than 1%, of
258 all calibrated event. It is a more accurate number than the
259 previously used numbers, because they only take the first
260 calibration (ignoring the interleaved calibrations) into account.
261
262 - database: The database now has two other new values UnsuitableMax and
263 DeadMax. They express the maximum number of pixels which were
264 unsuitable, respectively dead, during the sequence. Because
265 of high pedestal rms (cars passing) a few events with very high
266 numbers of unsuitable pixels can happen. Not to suffer from this
267 effect we don't take the highest 0.1% of the numbers into account.
268
269 - general: fixed a bug which caused callisto and star to stop working
270 properly because the callisto output was currupted
271
272 - general: a script called scripts/makemovie has been added which
273 simplified the process of producing several movies from a single
274 sequence with different setup.
275
276 - callisto: Some more code cleanup. Started to remove old obsolete
277 code from cvs.
278
279 - callisto: The extraction of the pedestal with the extractor was
280 not random. It seems that extracting at one position is still biased
281 (for example in the first or last slices we could still suffer from
282 switching noise) Now it is completely random.
283
284 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
285 pedestal files) individual pixels could be skipped due to high
286 variations. This was already the case for the pedestal extraction
287 from the lo-gains since the beginning and properly handled
288 there, but was introduced in the extraction from the pedestal files
289 a while ago. To calculate the average value it was still divided
290 by the number of events procesed not by the number of summands
291 really summed. This let to a pedestal which was a tiny amount too
292 small (for a few piels in the order of 0.1%). This led to an slightly
293 positive offset of the randomly extracted pedestal for a few pixels.
294 I doubt that this has a big effect on the result, because the effect
295 on the individual numbers is quite small. Due to this it is suggested
296 that you rerun your calibration to make sure you are without any
297 avoidable bias.
298
299 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
300 the median rms of the absolute arrival time and expressed in significance
301 levels. This replaces the old meaning of an abolute upper limit. An
302 absolute upper limit doesn't make much sense, because in our data
303 all arrival times are shifted at the same time (in fact it might be
304 a shift of the artificial trigger w.r.t. to the light flash).
305
306 - callisto: Added a new tab "BadPixTm" which shows the time evolution
307 of the number of unsuitable pixels over the whole sequence. This
308 is usefull mainly to judge if an intermediate calibration had
309 problems.
310
311 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
312 of the number of dead pixels over the whole sequence. Dead pixels
313 in this context are unmapped pixels, i.e. pixels which could not
314 be interpolated, and thus are ignored in the further analysis.
315
316 - callisto: It is now possible to use the position of the maximum
317 of the spline as arrival time instead of the leading edge even
318 when using the integral for the signal. Therefor set the extraction
319 type to kIntegralRel ("IntegralRelative") and the relative height
320 ("HeightTm") to -1:
321 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
322 MJPedestalC1.ExtractSignal.HeightTm: -1
323
324
325
326
327 *** Version 1.1 (2007/04/27)
328
329 - general: The new class MGeomCamDwarf contains the camera geometry
330 for our prefered Dwarf camera and can be used to create general
331 geometries of roundish or hexagonal cameras.
332
333 - mars: The default cleaning is now abolute 8.5/4.0.
334
335 - mars: The resource file mars.rc now contains examples for MUX data
336
337 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
338 data containing only 10-bit information is still cooked down to
339 8-bit, by cutting away the lowest 8-bit.
340
341 - merpp: When reading raw data the data is now stored in a single
342 array. The lo-gain array is obsolete. The interface stays the same.
343
344 - callisto: To process the new MUX data use the resource file
345 callisto_mux.rc
346
347 - callisto: The -root and -raw options to read merpped raw data have
348 been removed
349
350 - callisto: If the -mc option is given the sequence-name can now be
351 replaced by the MC sequence number
352
353 - callisto: If the sequence file contains "MonteCarlo: Yes" the
354 -mc option can now be omitted
355
356 - callisto: Started further simplification by removing obsolete
357 dependancies on MCalibIntensity*Cams.
358
359 - callisto: removed unsused intensity calibration from MJCalibration
360 for further simplification
361
362 - callisto: for simplification removed references to
363 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
364 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
365 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
366 (this should at minimum change nothing at all, and at maximum
367 improve thing if these containers where somewhere not handled
368 properly)
369
370 - callisto: Added the option to write an event movie. Please use
371 this option with care (huge files) but exessively to understand
372 our events. For further documentation please refer to the
373 IACT wiki
374 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
375
376 - callisto: Improved binning for the pulse position check histogram
377
378 - callisto: The code calculating the pulse position checknow takes
379 the pedestal into account
380
381 - callisto: The arrival time is now stored with full precision this
382 helps to get rid of artefacts in histograms. For the signal this
383 is not necessray because it is displayed in log-scale anyhow
384
385 - callisto: Fixed a problem with internal exclusions. Pixels which
386 have once been marked as unsuitable didn't get the necessary
387 histograms filled anymore to be rechecked with each interleaved
388 calibration.
389
390 - callisto: The relative arrival time resolution (the rms of the
391 relative arrival time offset) is now checked against its
392 median and the median deviation, instead of the average
393 plus an absolute offset.
394
395 - callisto: The relative arrival time offset is now calculated
396 w.r.t. its median not w.r.t. to an artificial reference pixel.
397
398 - callisto: The relative time calibration now marks pixels with
399 outlaying offset as unsuitable
400
401 - callisto: The interleaved relative time calibration has been switched
402 on. The advantage is that pixels which are marked as outliers
403 now can recover. An improvement over time is not expected, because
404 the relative time calibration seems stable.
405
406 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
407 option can now be omitted.
408
409 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
410 or the option "-mc" is specified as default the monte carlo datacenter
411 paths (/magic/montecarlo/...) are used if not overwritten in the
412 dataset file.
413
414 - ganymed: The output files now contain run- and event-number for all
415 events, accessible as RunNumber.fVal and EvtNumber.fVal
416
417 - ganymed: Added a plot showing the source position in the camera also
418 for wobble mode
419
420 - ganymed: In addition to the existing task which can be setup to
421 be executed after Cut1 a final task called "EstimateEnergy"
422 has been added, executed before writing the final output
423 (ganymed00000000.root). The task setup in all three cases
424 can be choosen individually. (For all three(!) cases you
425 can for example choose MRanForestCalc. For examples see all
426 sponde*.rc and all ganymed*rc)
427
428 - ganymed: If a container "MEstimatedEnergy" is found in the
429 parameter list (eg. because it was setup by MEstimateEnergy)
430 it will be written to the output file.
431
432
433
434 *** Version 1.0 (2007/02/16)
435
436 - database: Website to plot values from the database has been added.
437
438 - database: The rate of spark events as found by star is now kept
439 and the rate after cleaning is now with spark events subtracted
440
441 - general: The changes to the interpretation of phrases lead to
442 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
443
444 - general: Added example files how you can create your own calendar
445 (eg. as christmas present) with Mars. Just run
446 root macros/tutorials/calendar.C
447
448 - general: Added a possibility to display grouped data in the plotdb.C
449 macro (and similar macros). This allows to plot hourly, nightly,
450 weekly, monthly and yearly averages.
451 For more details see the plotall function of the macro
452
453 - general: fixed the error display of the camera display. It showed
454 wrong results.
455
456 - general: fixed a memory leak when reading many MStatusDisplays
457
458 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
459 between a spherical and a parabolic mirror
460
461 - callisto: We have a new pulse position check which takes the properties
462 of the extractor automatically into account. So no need to set
463 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
464 left is done. If possible the lo-gain extraction start and hi-gain
465 extraction end is changed accordingly. If no proper extraction range
466 can be set (hi-gain too much to the left) an error is raised.
467
468 - callisto: New swapped pixels have been found and corrected
469
470 - callisto: Redone the signal extraction this includes:
471 + Unified the algorithms to extract the pedestal for all pedestal
472 extractions done
473 + Unification of hi- and lo-gain into one array
474 + Unification of hi- and lo-gain extraction for Spline and
475 Digital Filter (means now exactly the same algorithm is used,
476 not a copy-and-pasted one)
477 + Store pedestal subtracted data in a common place
478 + Improved extraction algorithms. If the algorithms search a
479 maximum but don't find one they don't return the maximum anymore
480 + Improved the extraction such that a information for signal
481 and time which is consistent is returned
482 + replaced the numerical spline with a (not slower) analytical
483 solution
484 + Lowered the saturation limit from 250 to 245 to make sure that
485 we are far away in all pixels from problems with the clock-noise
486 + The start of the lo-gain extraction is calculated from the hi-gain
487 arrival time. In case of saturation an estimation is used.
488 + the hi-gain window was extended to slice 16. This allows extraction
489 of very late pulses in single pixels or of huge hadron showers.
490 + Now uses the lo-gain extraction range for pedestal extraction,
491 not the hi-gain range in the lo-gain
492
493 - callisto: New hi-/lo-gain calibration constants have been produced
494 for all periods from the statistic of the whole period. They are
495 now used automatically depending on the periods. The old constants
496 where deviation in avarega about 2%-3%. The constants are very
497 stable from period to period (<<1%) except for exchanged channels.
498 In a few cases the constants used so far were off by 1%-2% (maybe
499 temperature effects?)
500
501 - callisto: To gain obsolete space we do not write the
502 MPedestalFundamental anymore. Also calibration and bad pixel
503 treatment is not done for it anymore because it has never been used.
504
505 - callisto: Fixed a bug in the seuqence handling which caused the
506 light condition to be ignored
507
508 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
509 basically the same as "Cleaned" but the distribution devided into
510 the events fullfilling a spark cut or being rejected by it.
511 This cut can be changed from star.rc (see example inside) by
512 the "SparkCut" directive
513
514 - star: Star displays now the average individual pixel-rate (IPR) versus
515 time and the average discriminator threshold (DT) of all pixels.
516
517 - optim: fixed a problem with the optim-macros which was due to a bug
518 in the new phrase parsing
519
520 - ganymed: To get a nice FalseSource plot (instead of the all-information
521 debug plot displayed as a standard plot) use the context menu
522 somewhere between the two upper plots, click on "DrawNicePlot"
523 and enjoy the result. (It is the same context menu which contains
524 the other options)
525 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
526
527 - ganymed/optim/train: The cut program, trainings- and optimization
528 macros could run with less files found than expected from the
529 sequence-files. No the execution is stopped in this case.
530
531 - ganymed: now stores the dataset in the output file with all information
532 contained (as sequence number, sequence path, data path) so that the
533 used dataset file can be recreated complete from the output
534
535 - sponde: now also allows the uasge of random forest
536
537 - sponde: added a plot showing the cut efficiency
538
539 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
540 errors (eg. effecting the collection area) because the errors of the
541 two histograms were swapped in the calculation, which makes a difference
542 in the case the histograms contains weighted events. Aditionally the
543 totalarea was incorrectly taken into account, which results in too small
544 errors, which makes a difference at low statistics were the errors
545 or the collection area dominate.
546
547
548
549 *** Version 0.10.3 (2006/10/23)
550
551 - database: Implemented ObservationMode flag in websites.
552
553 - database: For sequences there is now also the stoptime available on the
554 websites.
555
556 - database: Removed ManuallyChanged flag from sequence-info websites,
557 as it is not needed anymore with the new sequence building algorithm.
558
559 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
560 Class for calculation of confidence intervals (upper limits).
561 Use model 3 or 4 for upper limit calculation for MAGIC observations.
562 Please read the class instruction of TRolke for more information.
563
564 - general: The programs now return 0xfe if the requested resource file
565 doesn't exist.
566
567 - general: Errors comming from root itself are now not output to
568 stderr anymore but to our default (colored) log-stream.
569
570 - general: Changed the interface to TFormula such that now everything
571 is parsed by TFormula, which should allow to use phrases even
572 without paranthesis correctly parsed.
573
574 - callisto: replaced the AdHoc number of effective integration slices
575 in the digital filter by an average of the correct number, averaged
576 over all possible set of weights. This also gives correct numbers
577 for the lo-gains which were totally wrong before.
578
579 - callisto: drastically reduced memory consumption by not storing
580 all intermediate calibration results in memory anymore (we might
581 write them into a file in the future)
582
583 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
584 debug plot displayed as a standard plot) use the context menu
585 somewhere between the two upper plots, click on "DrawNicePlot"
586 and enjoy the result. (It is the same context menu which contains
587 the "DrawAll" option)
588 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
589
590
591
592 *** Version 0.10.2 (2006/10/15)
593
594 - general: changed the building of the sequence files such, that
595 the source-/project name in case of wobble-sources is not the
596 source/project of the first data run anymore but the new generalized
597 wobble source/project
598
599 - general: Added some functions to MAstro to calculate sun and
600 moon properties
601
602 - general: Added two new macros (starvisday.C and starvisyear.C)
603 which allow to plot the visibility of several stars in one day
604 or of one star along one year
605
606
607
608 *** Version 0.10.1 (2006/10/11)
609
610 - general: HTML logging output was distorted... fixed.
611
612 - general: Changed the writing of the sequencefiles such that only
613 as many pedestal files as giving at least 1000 pedestal events which
614 are nearby the first calibration run are used as pedestal runs
615
616 - sponde: In the calculation of the collection area(s) and the
617 distribution for MOnte Carlo and estimated energy the error
618 calculation was wrong because root didn't take the errors
619 properly into account... fixed.
620
621
622
623 *** Version 0.10 (2006/10/10)
624
625 - general: all executables now check consistency of the root version
626 installed with the root version used for compilation. The return
627 code in this case is 255.
628
629 - general: The algorithm to build seqeunces has been redesigned
630 completly. It is now more flexible in terms of a resource file
631 resources/sequences.rc which can be used to partly overwrite
632 the default algorithm and defined the important part of the
633 algorithm. It also takes correctly into account several ways
634 of taking wobble-data. Currently the new algorithm doesn't take
635 the number of pedestal events anymore into account (so a sequence
636 could have much less than 1000 pedestal events and data runs are
637 no-more used instead)
638
639 - general: a lot of small changes to make the code compatible with
640 root 5.12/00 and gcc 4.1
641
642 - general: Fixed some warnings thrown if more warnings are switched
643 on in the compiler
644
645 - general: Added a function to MMath which returns the Median of
646 the distribution abs(y[i]-median) but at 68:32 division instead
647 of 50:50, which is somehow the median counterpart of the rms.
648
649 - general: MAstroCatalog allows now to read calatog files (as bsc5)
650 even if they are compressed with gzip (recommended compression
651 is with "-1")
652
653 - showplot:
654 + batch mode creation of image files now works with root 5.12/00
655 + added support for writing bmp (though it never produces
656 bmp which can be read by programs like xv or gimp)
657 + added support for xml
658 + added new option to start the display with a different size, by
659 --display-width=nnn or --display-height=nnn
660 + added options to define the canvas size when the display is started
661 --canvas-width=nnn or --canvas-height=nnn
662 the option can also be used for batch-mode conversion
663 + added an option which automatically fits the display size to the
664 desktop-size: --auto-size
665
666 - merpp: didn't recognize files with the extension .raw.gz - fixed.
667
668 - merpp: allow the reports to have 1000ms due to a bug in the camera
669 program.
670
671 - callisto: New swapped pixels have been found and corrected. For
672 details see MRawRunHeader::FixAssignment()
673
674 - callisto: Callisto now raises an error if one of the input files could
675 not be opened.
676
677 - callisto: In some rare cases it could happen that in the signal
678 extraction of the digital filter the extractor returned nonsense
679 results due a wrong initializion of a variable (this happens in
680 cases in which the extracted signal is exactly zero or the
681 digital filter couldn't slide because of a too small extraction
682 window, which could happen in the lo-gain extraction)
683
684 - callisto: The lo-gains have been marked as valid in some cases
685 when they got not extracted at all (deltsumlo=deltatimelo=0) because
686 the allowed extraction range (fLoGainLast-fLoGainFirst) was
687 smaller than the number of slices (fLoGainWindowSize) needed
688 by the lo-gain extractor
689
690 - callisto: Updated absolute calibration constants (muon calibration)
691
692 - callisto: fixed a bug which caused the hi-gain saturation not
693 to be handled properly in the spline (the position of the
694 saturation was calculated incorrectly)
695
696 - callisto: fixed a bug which gave weird results if hi- _and_
697 lo-gain could not be extracted properly. In some cases hi-
698 and lo-gain have not been extracted at all and the random result
699 got calibrated. In other cases the hi-gain was saturating and the
700 lo-gain has not been extracted. For this a completly arbitraty
701 scale factor was applied to the result from extracting the
702 charge of the saturating hi-gain.
703
704 - callisto: improves handling of extracted signal if lo- and/or
705 hi-gain could not be extracted properly. If no appropriate
706 calibration of either the signal or the arrival time is possible
707 the pixel is now markes as unsuitable instead of estimated.
708
709 - callisto: Fixed a problem in the spline extraction which gave
710 weird results if the signal was extracted from the first (and
711 highest) slice (as a workaround extraction from the first
712 slice has been forbidden)
713
714 - callisto: Fixed a bug regarding the use of the QE which doesn't
715 effect the result because the default is used anyhow.
716 (The bug was there since 14/07/2005)
717
718 - callisto: Changed the default for fgLoGainStartShift to -2.4
719
720 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
721 factors to be always 10 for all pixels as soon as the first
722 calibration update has happend.
723
724 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
725 was off by more than one slice (which gives wrong values for
726 pixels which have saturated the hi-gain) This was a problem
727 mainly for timing studies, not so much for the automatic standard
728 analysis. Also the values for the Spline have been changed slightly:
729 + Digital Filter from 1.70 to 0.95
730 + Spline from 1.39 to 1.30
731 The numbers were sorted out by an extensive test in the
732 test-database.
733
734 - callisto: Removed the tab showing the average calibrated arrival
735 time. It never gave useful information.
736
737 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
738 lo-gain pulse for data pulses if hi- and lo-gain have saturated
739 and both were extracted because the hi-gain was above the
740 LoGainSwitch.
741
742 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
743 lo-gain pulse position (after application of LoGainOffset, which
744 means in the ideal case it is 0) for data pulses if hi- and lo-gain
745 have saturated and both were extracted because the hi-gain was above
746 the LoGainSwitch.
747
748 - callisto: After extensive tests a new threshold level for determination
749 of the pulse position has been found at 50phe. This is due to the
750 fact that for lower pulses the arrival time changes its average
751 behaviour dramatically. It tends to the average of the extraction
752 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
753
754 - callisto: Added two more plots to the calibration part. The average
755 extracted signal and the average extracted arrival time as
756 extracted by the signal extractor (This can help debugging problems
757 because it doesn't involve a fit)
758
759 - star: changed the fit for the effective on time such that initial
760 values are calculated automatically now instead of using build
761 in values. This makes the fit more indepedant of the underlaying
762 rates. With a test of ~350 sequences in the test database it could
763 be shown that the new fit gives the same result +/-1sek.
764 The highest deviation was +5s the lowest -10s. You can now control
765 the bahaviour with two resource values:
766 MHEffectiveOnTime.FistBin: 3
767 MHEffectiveOnTime.NumEvents: 12000
768 Use FirstBin=1 and NumEvents=120 to fit the effective on time
769 from the resulting gamma candidates
770
771 - star: The Center histogram in MHHillas is now by default displayed
772 with the colz draw-option
773
774 - ganymed: now produces valid error codes if failed
775
776 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
777 with the option "hadronness" instead of "area" or "both" if
778 you want to use both cuts. The hadronness cut includes a fixed
779 cut in hadronness (index 8) and a fixed cut in size (index 9).
780
781 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
782 the M3Long of the anti source to be not properly evaluated
783 (actually is was evaluated as a unique random number) in case
784 of optimization with anti-theta cut switched on. This might have
785 lead to improper, but not necessarily wrong, optimization results.
786
787 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
788 how to use random forest
789
790 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
791 ganymed_onoff.rc. Seems to be unintentional that they were different.
792
793 - sponde: Since the introduction of the possibility to define a
794 normalization energy instead of using the integral the default
795 was not using the integral anymore but a normalization energy of
796 1GeV. It is now the integral again.
797
798 - sponde: Fixed a problem in the weighting which did not allow
799 a MC slope of -1.
800
801
802
803 *** Version 0.9.6 (2006/05/24)
804
805 - general: changed the binning of the azimuthal profile of the camera
806 such that it is aligned with the 60deg boundaries.
807
808 - merpp: better handling of problems with the TH, TD part of the
809 CC-REPORT for files older than 200507190 and 200412210
810 respectively
811
812 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
813
814 - merpp: implementd latest changes in starguider reports (sinc 9th May)
815
816 - callisto: if an arrival time is extracted outside the fadc range is
817 was set to the boundary before. Now a random number is assigned
818 instead to avoid unfortunate coincidences of arrival times just
819 by this arbitrary value.
820
821 - callisto: added a new option to callisto.rc which allows
822 to set the maximum arrival time difference allowed for the
823 badpixel algorithm to determin whether a pixels belongs to a shower:
824 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
825
826 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
827 to 0.9 as suggested by Stefan due to a recent study on the fraction
828 of pixels surviving the image cleaning
829
830 - callisto: switched off error in case of "pulse is too much to the left"
831
832 - callisto: The extraction window is not adapted anymore. This means that
833 the pulse is extracted from the full range. The draw-back is that the
834 background (pedestal) will become slightly higher. Switching on/off
835 the PulsePosCheck in the callisto.rc only effects filling the
836 histograms.
837 WARNING: If the pulse is too much to the left data is calibrated!
838 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
839 in the database to make sure that your data is valid!
840
841 - star: Show also the number of stars correlated correctly by the
842 starguider
843
844 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
845 than one off-source region in wobble-mode. To use it add the following to
846 your ganymed_wobble.rc:
847 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
848 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
849 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
850 + Cut1.ThetaCut: None
851 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
852
853 - ganymed: in the case the latest report is older than a default (currently
854 one minute) and the current report will be skip the starguider
855 correction and calibration will be reset. The maximum age can be
856 setup from ganymed.rc by (minutes):
857 MPointingDevCalc.MaxAge: 1.5
858
859 - ganymed: A first implementation showing all size-bins for the theta-sq
860 resp. alpha-plots in a single tab automatically
861
862
863
864 *** Version 0.9.5.1 (2006/05/05)
865
866 - general: Added a new option "zdiff" to the Makefile which runs
867 "cvs diff" as "make diff" would do, but with compression
868
869 - general: accelerated MTFillMatrix (used for eample in all training
870 and optimization macros) by skipping some obsolete calles in the
871 eventloop the first and second loop could be accelerated by ~20%
872
873 - general: Added a missing feature in the MFilterList class which
874 prevented MFEnergySlope from working correctly in trainenergy.C
875
876 - general: Accelerated the random forest training and usage a bit
877
878 - merpp: Adapted to new raw data file format version 6
879
880 - merpp: fixed a problem with reading the starguider reports
881 after 6.3.2006
882
883 - callisto: At some times six pixels had to be exchanged manually in the
884 data. If the pixels to be swaped are both not found, an error was raised
885 and calibration was stopped. Now it is assumed they are intentially not
886 mapped and the Error has been changed to a Warning.
887
888 - star: Added new image cleaning based on the arrival time of the shower.
889 The new cleaning can be accessed using the parameter "Time" instead of
890 the the old one (like "Absolute) in the star.rc-file.
891 Recommended parameters:
892 + MImgCleanStd.CleanLevel1: 8.2
893 + MImgCleanStd.CleanLevel2: 5
894 + MImgCleanStd.CleanRings: 2
895 + MImgCleanStd.KeepSinglePixels: No
896
897 - star: Simplified the calculation of the effective on time. By letting
898 the fit start in the third bin the result should become more stable.
899 The fit quality is now ignored for the theta-plot which is not used
900 in the analysis later. Still better pre-cut which, for example,
901 remove events triggered by car-light (rate changing on a short
902 time-scale) are missing.
903
904 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
905 for optimization (kWeakSource) which is suggested by the Berlin
906 people for weak sources.
907
908 - macros: plotdb.C:
909 + if no dataset and no time-interval is given only sequences with
910 an effective on-time above five minutes are plotted anymore
911 + added a new tab "RelTime" displaying the relative on-time
912 (effective on-time divided by the observation time)
913
914 - macros: optim*.C: by skipping some obsolete calles in the eventloop
915 the optimization became a lot faster
916
917 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
918 To display them just delete the pads displayed on top.
919
920 - ganymed: fixed a bug which could cause strange behaviour in wobble
921 mode if no starguider information was available due to an incorrect
922 initialization of the starguider calibration
923
924 - ganymed: The scale region in the False Source Plot (MHDisp) can now
925 be changed from within the plot. It can also be setup from the
926 resource file using:
927 + MHDisp.fScaleMin: 0.325
928 + MHDisp.fScaleMax: 0.475
929
930 - ganymed, showplot: Fixed a problem with the fit to the off-data
931 (HistOff) which could cause a time lag or an inifinite loop.
932 The bug did not effect the results at all.
933
934 - sponde: Added a new tab showing the effective collection area after
935 trigger (including the software trigger)
936
937 - sponde: MMcSpectrumWeight has a new option which allows to define
938 the scaling factor not by the integral of the events but at
939 a defined energy:
940 e.g. MMcSpectrumWeight.NormEnergy: 200
941
942 - MTFillMatrix, sponde: by skipping some obsolete calles in the
943 eventloops the loop could be accelerated by ~20%
944
945
946
947 *** Version 0.9.5 (2006/03/13)
948
949 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
950 and added the standard Disp-parametrization
951
952 - macros: added a new macro datacenter/macros/plotstat.C allowing
953 to plot statistics about the data processing
954
955 - macros: added a new macro to plot the muon correction coefficients
956 versus period (macros/plot/mucal.C)
957
958 - showplot: path inflation for ganymed files was broken
959
960 - callisto: Fixed an important bug. When the number of saturating pixels
961 were calculated the bad pixel information already available from the
962 calibration was ignored. This yields wrong values in case pixels
963 are broken and saturate all the time or randomly.
964
965 - callisto: Updated Muon calibration constants. Spline data now also uses
966 different values for different periods
967
968 - star: The time-evolution shown in the effective on-time plot now displays
969 the axis range (if there are no holes it should be similar to the
970 effective on-time)
971
972 - star: Added two new image parameters:
973 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
974 the three pixels next to the center of gravity and the size
975 + MNewImagePar.fConcCore: The ratio of the signals of all
976 pixels inside or touching the ellipse and the size
977
978 - ganymed: now stops in requested source isn't found in catalog file
979
980 - ganymed: Many improvements to the phi-plot in wobble mode:
981 + with a template the ideal background is displayed
982 + a possible camera inhomogeneity is taken into account
983 + the anti theta cut is better supported
984 + the phi cut is automatically calculated from the theta cut
985 See the examples in ganymed_wobble.rc for more details.
986
987 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
988 times the bin-width instead of the absolute energy
989
990 - ganymed: New cuts for on/off and wobble mode
991
992 - ganymed: The smearing of the False Source plot has been increased
993 to 0.06
994
995 - ganymed: The starguider calibration can now be changed from the
996 resource file.
997 See the examples in ganymed*.rc for more details.
998
999 - ganymed: added a new option for on-/off-observations
1000 MJCut.RandomSourcePosition
1001 If switched on the distribution of observation time of the source
1002 position in the camera is calculated from the on-data and randomly
1003 applied with this distrbution to the off-data.
1004
1005 - ganymed: by skipping some obsolete calles in the eventloop the
1006 first and second loop could be accelerated by ~20%
1007
1008 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1009 position in the off-data randomly according to its distribution in the
1010 on-data.
1011
1012
1013
1014 *** Version 0.9.4.3 (2006/02/13)
1015
1016 - general: Fixed a bug in most of the programs which prevented the
1017 compile date in the startup message to be displayed
1018
1019 - general: Simplified program calls. The following abbreviations
1020 are now possible:
1021 showlog callisto 55599
1022 showplot signal 55599
1023 star 55599
1024 callisto 55999
1025 ganymed 2
1026 In this cases the corrsponding root-, log-, sequence- or dataset-
1027 filename is automatically compiled using the default datacenter
1028 paths ("/magic/*")
1029
1030 - general: Fixed a long outstanding bug which made axis tick marks
1031 disappear if MDataFormula was used (eg. abs(x))
1032
1033 - general: Updated MMath with new functions to calculate the results of
1034 a exponential, logarithmic and powerlaw fits analytically.
1035
1036 - general: Updated some macros with comments:
1037 + macros/optim/optimdisp.C
1038 + macros/optim/optimenergy.C
1039 + macros/optim/optimwobble.C:
1040
1041 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1042 files) now allows adding a pre-cut like in the optimization. E.g. this
1043 is useful to perform g/h-separation cuts before training the random
1044 forest.
1045
1046 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1047 correctly assigned in the raw data assignement table. A fix to correct
1048 the assignment tabel have been implemented.
1049
1050 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1051 by 90, 180 and 270 deg.
1052
1053 - general: the macro plotdb.C now allows to highlight sequences belonging
1054 to a datset. For more details see the descritions in the macro.
1055
1056 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1057 of the display, it gave wrong results espacially for big sizes.
1058 Now the embedded canvas should always have a ratio width/height=3/2.
1059 The "Size" options have been updated with values fitting the 3/2
1060 size ratio.
1061
1062 - RanForest:
1063 + Updated the random forest classes to support also the
1064 regression method implemented by Thomas H.
1065 + added new tutorial macro how to train the random forest
1066 for energy estimation (macros/optim/rfenergyest.C)
1067 + new classes to train the random forest (still in development)
1068 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1069 + new tutorial macros for random forest training in macros/train
1070 trainenergy.C, traindisp.C, trainseparation.C
1071
1072 - mars: now allows to setup a cut in the resource file mars.rc to choose
1073 the events to be displayed, eg:
1074 Cut.Condition: {0} && {1}
1075 Cut.0: MHillas.fSize>100
1076 Cut.1: MHillas.fSize<900
1077
1078 - merpp: Made aware of the new .rep format 200510250. This includes
1079 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1080 the discriminator thresholds (MCameraTD) and the disciminator
1081 delays (MCameraTD). All of them come with the CC report and are therefor
1082 written to the CC tree.
1083
1084 - callisto: fixed a bug in the calculation of the arrival times in
1085 the Digital Filter. They were all shifted by the same amount
1086 fHiGainFirst. This caused an offset in the order of the position of
1087 the left border of the extraction window in the times calculated
1088 from high-gain and from low-gain. The bug effected only the absolute
1089 arrival times. The bug was there since 30.1.2005.
1090
1091 - callisto: Changed the ExtractionWindow for the pulse position check
1092 such that the camera inhomogeneity becomes as less as possible and
1093 comparable to the pulso position check switched off. More details
1094 on the study will be given at our result web-page.
1095
1096 - ganymed: ganymed.rc, ganymed_onoff.rc:
1097 changed to new cuts trained with 1ES1218 and Crab-data
1098 for maximum sigma*log10(excess)
1099
1100 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1101 a new option was implemented to estimate Disp (CalcDisp)
1102
1103 - ganymed: Implemented two new options which allow
1104 to overwrite the default path to search for the sequence files
1105 --ins=/magic/sequences
1106 and where to search for the image data
1107 --ind=/magic/data/star
1108
1109 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1110 dx/dy from the resource file by
1111 MSrcPosCorrect.Dx
1112 MSrcPosCorrect.Dy
1113
1114 - ganymed: fixed reading the source catalog. Only as many chars
1115 as the requested source name had were compared (If a source
1116 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1117 were requested it could happen that the coordinates of
1118 "1ES1218" were read) The source coordinates are now printed
1119 in addition to its name to the logging output.
1120
1121 - ganymed: changed the background fit in the case of a ThetaSq function
1122 from a polynomial to a exponential, this should give a big improvement
1123 for on-only analysis'
1124
1125 - ganymed/sponde: Calculation of the error of single size-/energy-
1126 bins now uses Li/Ma (5) instead of LiMa (17)
1127
1128 - sponde: Added a plot E^2*dN/dE
1129
1130 - sponde: The energy estimator plot should now show values like
1131 they are commonly used.
1132
1133 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1134 (a powerlaw with cutoff didn't work before)
1135
1136
1137
1138 *** Version 0.9.4.2 (2005/10/01)
1139
1140 - general: added new tutorial macro macros/tutorials/threshold.C:
1141 how to calculate the threshold
1142
1143 - general: added a new game. Start it from the interpreter with
1144 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1145 and MagicReversi)
1146
1147 - general: neighbor pixels in MGeoms are now sorted clockwise
1148
1149 - merpp: made aware of new format 20050829-0
1150
1151 - callisto: New scale factors from muon analysis, stored in new
1152 resource file resources/calibration.rc
1153
1154 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1155 the eventloop if something went wrong. This is necessary for the
1156 automatic processing
1157
1158 - callisto: Implemented a new treatment for the time information
1159 developed by S.Ruegamer, this should give much better response than
1160 the old very primitive algorithm. This is especially important
1161 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1162 treatment was buggy! As neighbor pixels to interpolate the
1163 arrival times always the pixels 0 to 5 were taken)
1164
1165 - callisto: In addition to the new treatment of arrival times the
1166 decision of the treatment whether a pixel contains shower
1167 information or not is used to improve the signal interpolation
1168 further. Previously interpolated pixels showed a non-zero signal
1169 do the peak searching signal extractors. Having a signal pixel
1170 beside raised the signal above the cleaning level. Thus the
1171 pixel survived cleaning to often but with a too low mean signal.
1172 By replacing empty pixels with a gaus (mean and rms from the
1173 corresponding Area entries in MPedPhotCam) this effect can
1174 be supressed.
1175
1176 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1177 got lost when the events were stored by the calibration... fixed.
1178 (This was no problem for normal image cleaning because the pixel
1179 content was artificially set to 0 not surviving standard cleaning
1180 algorithm)
1181
1182 - callisto: Fixed a bug which caused the random and peak-search pedestal
1183 extracted with an extractor to be exchanged for the first (roughly)
1184 500 events (*Extractor and *ExtractorRndm).
1185 (They were simply exchanged in callisto.cc) This bug might have been
1186 introduced in Mars 0.9.4 when the order of calculation of the two
1187 types of pedestal in callisto got exchanged. The bug only effects
1188 the first seconds of data of each sequence.
1189
1190 - star: Taking the arrival time of Muons into account the calculation
1191 of the parameters could be made independant of the noise
1192 (pedestal rms). The dependance was due to the bias of the peak search
1193 extractor. Now only a ZA dependamcy is left which is not yet fully
1194 understood.
1195
1196 - ganymed: The sequences were still not sorted correctly in any case,
1197 because they were sorted by the full qualified path name. Now they
1198 are sorted by their sequence number.
1199
1200 - ganymed: new values for the spark-event-cut
1201
1202 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1203
1204
1205
1206 *** Version 0.9.4.1 (2005/08/18)
1207
1208 - callisto: fixed some problems with the calibration in case of
1209 inteleaved events. Therefor the final and some intermediate
1210 fits are skipped which would take place on partly filled #
1211 histograms and gave wrong results or failed completely.
1212
1213 - callisto: If the intermediate finalization of the histograms
1214 calculating the mean charge of the calibration signal fails
1215 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1216
1217 - ganymed: Fixed some bugs which caused problems in On-only mode.
1218 Still the false source plot doesn't give reasonable results.
1219
1220
1221
1222 *** Version 0.9.4 (2005/08/05)
1223
1224 - general: Fixed the ZA binning. It did not correctly fit the
1225 MC binning
1226
1227 - general: Added a class to correct for the missfocussing in
1228 April (MSrcPosCorrect)
1229
1230 - general: Random Forest energy estimator should now work properly
1231
1232 - general: MHCamera now displays the profiles in deg instead of mm
1233
1234 - general: MH::SetPalette offers a lot of new palettes
1235
1236 - general: MHillas - the case of CorrXY==0 is now handled properly
1237
1238 - general: implemented the possibility to change the line and
1239 marker style of a sky-grid drawn by MAstroCatalog
1240
1241 - general: Runs in sequences and datasets are now automatically
1242 ordered (it is assumed that the order of their filenames correctly
1243 represents the order of observations) to ensure correct reading
1244 of the subsystem data
1245
1246 - general: Runs cannot be added to a sequence twice anymore. Also
1247 Sequences cannot be added twice anymore to a dataset.
1248
1249 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1250 It gave wrong results by 1./2pi
1251
1252 - showplot: got a new option to start a root interpreter, too
1253
1254 - mars: now displays a rough estimate of Disp and the third moment
1255
1256 - mars: now displays the event time MTime if available
1257
1258 - mars: show muon parameters graphically
1259
1260 - mars: now the file to open can be given as commandline
1261 argument
1262
1263 - merpp: Added support for new arehucas version >= 200507190
1264 implementing values for three temperature sensors in the
1265 counting house (MCameraAUX) and the name of the HV settings file
1266 (MCameraHV).
1267
1268 - merrp: Also fixed some problems with wrong versions numbers stated
1269 by arehucas and implemented some fixed for old versions (<200407070)
1270
1271 - callisto: MCalibrationHiLoCam can now be printed from its context
1272 menu, eg in the TBrowser
1273
1274 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1275 - 1.39 (MExtractTimeAndChargeSpline)
1276 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1277 This is important mainly for timing studies.
1278
1279 - callisto: Changed limits in MHCalibrationChargeCalc from
1280 - -100.125 to -98 (fgChargeHiGainFirst)
1281 - 1899.875 to 1902. (fgChargeHiGainLast)
1282 - -100.25 to -99 (fgChargeLoGainFirst)
1283 - 899.75 to 901. (fgChargeLoGainLast)
1284 Introduced new limits:
1285 - fgNumLoGainBlackoutLimit: 0.05
1286 - fgLoGainBlackoutLimit: 3.5
1287 - fgLoGainPickupLimit: 3.5
1288
1289 - callisto: The handling of automatic weights for the digital filter
1290 has been improved. There are now new calibration weights special
1291 for Monte Carlo calibrations.
1292
1293 - callisto: Updated Muon scale with latest results (1% difference
1294 for most data, 5% for Mar/Apr'05)
1295
1296 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1297 was saturated and the blackout-events in the low-gain exceed the
1298 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1299 This excludes those pixels which have a saturating high-gain
1300 channel, but the low-gain switch does not switch often enough
1301 to make the distribution reliable.
1302
1303 - callisto: fix a bug counting the number of saturated events. Up to now,
1304 the number of saturated slices was counted (which is one for a not too
1305 high number), but for some (pathological) pixels, many more slices
1306 saturated and produced wrong limits.
1307
1308 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1309 + MCalibrationRelTimeCam.CheckFitResults: Yes
1310 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1311 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1312 + MCalibrationRelTimeCam.CheckOscillations: Yes
1313
1314 - callisto: introduce max. number of events for intercalibration,
1315 the rest gets skipped. Default: 4096
1316 The calibration causes too many un-reliable pixels if more
1317 than about 5000 events are treated (@500 Hz) because of the
1318 mode hopping of the VCSels. However, in the past, some
1319 calibration runs have been taken (erroneously) with more
1320 than 5000 events, especially the intensity scans where
1321 a good precision is needed.
1322
1323 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1324 photo-electrons for the spline extractor by 1-2% (correctly).
1325
1326 - callisto: The intercalibration is now done using a full f-factor
1327 method instead of a simple update. This makes things slower but
1328 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1329 changes.
1330
1331 - callisto: MPedestalY3 now uses the same extraction range as the data
1332 as calculated by MPedestalY2
1333
1334 - callisto: A check of the fraction of allowed unsuitable (10%) and
1335 unreliable (30%) pixels has been addded when the conversion is
1336 calculated from interleaved events
1337
1338 - star: fixed a bug which caused MEffectiveOnTime containers not to
1339 be written. In the worst case they were skipped almost all, in the
1340 best case they were all ok. It depends on how often the new value
1341 was assigned just with an event which was skipped later by another
1342 task
1343
1344 - star: new histograms MHPointing and MHRate
1345
1346 - star: New tab (Currents) displaying the time evolution of the mean
1347 DC currents
1348
1349 - star: New tab (MeanRms) displaying the time volution of the mean
1350 Pedestal Rms
1351
1352 - star: Output now contains MReportStarguider
1353
1354 - star: Improved muon analysis. Due to the absense of a constant
1355 for the gaus fit for arc width and the fact that the arcwidth
1356 plot was a histogram instead of a profile the resulting psf
1357 became pedestal rms dependant
1358
1359 - ganymed: added new plot (MHPhi) for wobble mode as described in
1360 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1361
1362 - ganymed: corrects now (correctly?) for the misspointing in
1363 May/April 05
1364
1365 - ganymed: Two new default templates for ganymed.rc are avilable:
1366 ganymed_onoff.rc and ganymed_wobble.rc
1367
1368 - ganymed: The first version of MFMagicCuts has been released
1369
1370 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1371
1372 - ganymed, sponde: There are two new options to determin the number
1373 of bins for the signal region (NumBinsSignal) and the number of
1374 total bins (NumBinsTotal) in the MHThetaSq histogram
1375
1376 - ganymed: optimized palettes for MHDisp
1377
1378 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1379 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1380 sqrt(2) to large
1381
1382 - ganymed: The false source plot (MHDisp) is now based on Disp
1383 and a background model determined in the first loop is
1384 subtracted
1385
1386 - ganymed: MFMagicCuts are now available in the cvs. The correct
1387 solution for the disp ambiguity problem is now calculated using
1388 the third moment. The third moment cut therefor is skipped.
1389
1390 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1391 already determined by the third moment along the major axis and
1392 so its actual sign is aligned along the major axis of the shower.
1393
1394 - ganymed: If starguider data is available it is taken into account
1395 when calculating the source position. This is especially important
1396 for wobble data at high zenith angles and culmination data.
1397
1398 - ganymed: If available the starguider data is taken into account as
1399 good as it is possible without a starguider calibration. To switch
1400 it off add
1401 MPointingDevCalc.MaxAbsDev: -1
1402 to your ganymed.rc
1403
1404 - sponde: the zenith angle distribution is now weighted instead of
1405 choosen by default. This gurantees higher statistics in the highest
1406 and lowest energy bins. To switch this behaviour off use...
1407
1408 - sponde: now automatically displays the energy threshold
1409
1410
1411
1412 *** Version 0.9.3 (2005/06/03)
1413
1414 - general: MMcEvt now derived from MMcEvtBasic which should
1415 have no influence on compatibility with older camera files
1416
1417 - general: Implemented a new option to MReadReports which allows
1418 to force reading of the first event of some trees (eg. Drive-tree)
1419 before any other tree.
1420
1421 - general: Made a fix to MPointingPosCalc which assumes that the
1422 run-type is real-data if Process is called before ReInit, such
1423 that also the very first Drive-events in a run are treated
1424 correctly.
1425
1426 - shoplot now displays the filename in the title bar of the window
1427
1428 - merpp: new options: --auto-time-start --auto-time-stop which
1429 allow to cut updating with slow-control at the start- or
1430 (previousle --auto-time only allowed: and) stop-time of
1431 the run stored in the runheader.
1432
1433 - callisto: changed default of fgFallTimeHiGain in
1434 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1435 already set as default in callisto_Dec04Jan05.rc
1436
1437 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1438 now changes the filename for new weights automatically for
1439 cosmics, MC and for different calibration colors.
1440
1441 - callisto: a problem with the order of some code cause the
1442 name of the weights file in MPedestalY2 to be ignored.
1443 Wrongly the calibration_UV weights were used instead
1444 of the cosmics weights set in callisto.rc.
1445
1446 - callisto: should allow ct1 pulser data when the color is
1447 explicitly set also for pretty new runs
1448
1449 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1450 to introduce an additional scale factor (should be around 1)
1451 to adapt for slight deviations in different extractors from
1452 the MC calibration. For MC calibrations the scale factor
1453 is fixed to 1
1454
1455 - callisto: MFCosmics should handle very high signals a bit
1456 more accurate now
1457
1458 - callisto: when calculating the mean pedestal rms for different
1459 pixel sizes or sectors also kUnsuitableEvt is now taken into
1460 account - not only kUnsuitableRun
1461
1462 - callisto: '-raw' option is now the default
1463
1464 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1465 This has the advantage that mean values in the calibration (eg
1466 arrival times) are calculated more accuratly.
1467
1468 - callisto: In the resource file callisto_Dec04Jan05.rc
1469 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1470
1471 - callisto: new Hi-/Lo-Gain intercalibration constants
1472 hilocalib_sp1.root and hilocalib_sp1_mc.root
1473
1474 - callisto: changed default for MJPedestalY2.MaxEvents
1475 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1476
1477 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1478 has changed from 9.0 to 6.0. This is necessary to exclude two very
1479 ringing pixels in September which - when kept - destroy the image
1480 cleaning around them (Markus G.)
1481
1482 - callisto: (!) The Muon analysis of all data taken so far has
1483 suggested that different extractors give slightly different
1484 absolute results after calibration, due to there different
1485 handling of the calibration- and cosmics pulse shape. Although
1486 the over all calibration seems to be a bit to pesimistic (or
1487 the MC seems to be a little bit - 3-5% - too much attenuated).
1488 There for correction factors have been introduced which correct
1489 the calibration constants by
1490 0.956937799 for Digital Filter (callisto.rc)
1491 and
1492 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1493 calibration. The main advantage is, that both data types can
1494 be easily analysed together and compared to the same MC sample.
1495 The factors are choosen such, that the reference is now a
1496 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1497
1498 - star: fixed a bug which caused the first bin of the histograms
1499 vs time to disapear in PostProcess. This gave wrong results
1500 on the screen. The output and all following programs not
1501 directly accessing the histograms haven't been affected
1502
1503 - star, ganymed: Made sure that always the first Drive-tree event
1504 is read and Processed before the first data event was read.
1505
1506 - ganymed: implemented the possibility to replace the standard
1507 false source plot with a different one. For example: If
1508 you want to use a Disp based FS plot use the resource:
1509 NameHistFS: MHDisp
1510 For details about the requirements of these plots look
1511 at the corresponding classes
1512
1513 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1514 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1515 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1516 case MAlphaFitter is setup correctly. For On-Only optimization
1517 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1518 RunOn() instead of Run(). For energy estimation MJOptimize
1519 has been replaced by MJOptimizeEnergy
1520
1521 - sponde: The input MC spectrum can now be weighted to fake a
1522 different spectrum. This is done via MMcSpectrumWeight. For
1523 more details see the class description and sponde.rc
1524
1525 - sponde: The paremeter comparsion plots are not scaled by
1526 their entries anymore. Instead the MC plot is scaled by using
1527 the result spectrum of the analysis. If the input MC spectrum
1528 and the result spectrum has different slopes the absolut
1529 normalization is normally wrong.
1530
1531
1532
1533 *** Version 0.9.2 (2005/05/20)
1534
1535 - general: Changed the default paths for calibrated data and image
1536 files. (The implemented access to these files doesn't yet exist)
1537
1538 - general: support for MRunIter has been removed from the job classes
1539 (use the setter functions of MSeqeunce instead)
1540
1541 - general: ProcessFile has been renamed to Process in all job classes,
1542 because ProcessFile is missleading
1543
1544 - general: The storage of the palette in MHCamera is now possible
1545
1546 - general: new bits describing unsuitable and unreliable pixels have
1547 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1548 kDeadPedestalRms, kFluctuatingArrivalTimes
1549
1550 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1551 versions newer than V200404070
1552
1553 - general: support for cc file versions newer than V200504130. Added
1554 support for active loads (MCameraActiveLoad) and central pixel
1555 (MCameraCentralPixel)
1556
1557 - general: added new histograms for image parameters versus size
1558 (MHVsSize)
1559
1560 - general: The eventloop now automatically calls PrintStatistics
1561
1562 - Status Display: Improved support for printing:
1563 + A default can now be set in .rootrc (for more details see
1564 MStatusDisplay::PrintPS)
1565 + A print dialog is opened so that printer and command line
1566 can be canged
1567
1568 - showlog: improved such that it handles different verbosity levels
1569 more accurate now. This mean you can suppress output when
1570 using showlog.
1571
1572 - showplot: improved
1573 + The new graphics formats have been implemented
1574 (pdf, svg, png, jpg and xpm)
1575 + Implemented an interface for printing. Because you can change
1576 the printing command from the command line you can use all
1577 the nice postscript tool. To print a booklet for example call:
1578 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1579 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1580 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1581
1582 - callisto: fixed a bug in the recognition of the calibration bit
1583 pattern. Concerns only intensity calibration. (The strength of the
1584 intensity has been updated in some cases)
1585
1586 - callisto: add a filter against PIN Diode events when running over
1587 calibration runs since some of the recent calibration runs have
1588 been taken with Pin Diode.
1589
1590 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1591 39943, 44833 in the calibration (MCalibColorSet)
1592
1593 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1594 been set to 1e-18 in callisto_Dec04_Jan05.rc
1595
1596 - callisto: in callisto_Dec04Jan05.rc: set value for
1597 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1598 statistics for the calculation of the mean pulse time
1599 of the cosmisc
1600
1601 - callisto: the charge limit in the calibration has been raised
1602 from 2.5 to 4.5
1603
1604 - callisto: new setup read from callisto.rc
1605 + MCalibCalcFromPast.fNumEventsDump
1606 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1607 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1608
1609 - callisto: MExtractTimeAndChargeSpline extractor:
1610 + The integration ranges were shifted by 0.2 FADC slices to the right.
1611 + unreliable handling of floating point values caused different
1612 results on different platform or with different compiler options:
1613 The new algorithm is numerically exact and more accurate because
1614 it doesn't calculate the integration position by multiple times
1615 adding the step-size (which results in numerical uncertanties
1616 exspecially if multiplied with large numbers)
1617 + A lot of fixes have been introduced which effects integrating the
1618 spline at the edges of the valid range. In this case any memory
1619 was randomly accessed. This behaviour can be tested replacing
1620 all MArrayF by TArrayF which perform a range check (but of course
1621 they are a lot slower)
1622 ! No result obtained with the Spline before can be trusted! Due to
1623 random memory access it might by completely random!
1624
1625 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1626 + extraction range in the high gain to 4.
1627 + weights file to cosmics_weights46.dat
1628
1629 - callisto:
1630 + introduce the check for fluctuating arrival times.
1631 + set charge limit to from 2.5 to 4.5
1632 + introduce asymmetric exclusion due to "deviating number of phes":
1633 Default: -9.0 +4.5
1634 + make deviating number of phes unsuitable (see David's findings).
1635
1636 - callisto: fixed the display of unsuitable pixels. The old change
1637 to a real profile in MHCamera broke it.
1638
1639 - callisto: The cosmics filter is used in MJCalibration now
1640 independant of the pulser color (formaly it was used only for
1641 CT1-pulser data). The threshold of number of max empty pixels
1642 has been raised from 2% to 5% in MJCalibration. The maximum
1643 fraction of rejected event is 50% otherwise the calibration has
1644 failed. The filter now ignores unsuitable pixels.
1645 Setup the filter from callisto.rc using "ContCosmics"
1646 (see MFCosmics::ReadEnv)
1647
1648 - callisto: changed default for fgOffsetFromLogain back
1649 from -2.8 to -1.8 in digital filter.
1650
1651 - callisto: for the common extractors
1652 + MExtractFixedWindow
1653 * MExtractTimeAndChargeSlidingWindow
1654 * MExtractTimeAndChargeSpline
1655 * MExtractTimeAndChargeDigitalFilter
1656 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1657 and fResolutionPerPheLoGain
1658
1659 - callisto: Updated the hi-/lo-gain intercalibration constants
1660 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1661 hilocalib_df6.root
1662
1663 - callisto: The default lo-gain extraction window for the
1664 MExtractTimeAndChargeSlidingWindow extractor has been increased
1665 from 6 to 8 to take the stretch of the pusle into account
1666
1667 - callisto (!!!): fixed an important bug in the setting of the
1668 incoming pedestal pointer to the signal extractor extracting
1669 pedestals. This bug caused the pedestals not to be subtracted
1670 correctly in the calibration afterwards. The effect was about 10%
1671 too high conversion factors for the digital filter and the spline
1672 and more than 40% for the sliding window.
1673 The bug existed since end of February! (Markus G.)
1674
1675 - star: added muon support to star. A new tab "MHMuonPar" is
1676 displayed. The lower right plot is an estimate of the point spread
1677 function. A reference value is displayed. To get the real PSF
1678 you must compare with MC. The setup for the muon analysis
1679 is done in star.rc. More informations can be found in
1680 MHSingleMuon and MHCalibParCalc
1681
1682 - star: The weather data is now displayed in star
1683
1684 - star: MEventRateCalc handles the calculation of the event rate more
1685 accurate now in case of the start of a new run inside a sequence
1686
1687 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1688 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1689 changed only minimally
1690
1691 - ganymed: (MJCut and MJOptimize) now displayes the number of
1692 excess events versus size. The energy estimation is done in
1693 MJSpectrum (sponde)
1694
1695 - ganymed: got support for using other variables than Alpha, eg. Theta.
1696 Therefor you need a class deriving from MHAlpha which supports
1697 this variable (one is already existing: MHTheta, which is now the
1698 default in ganymed). It is setup through ganymed.rc
1699
1700 - added a full featured spectrum program (sponde) which reads
1701 ganymed output and monte carlos and compiles a spectrum
1702
1703
1704
1705 *** Version 0.9.1 (2005/04/14)
1706
1707 - Fix bug on the arrival time reconstruction when using Digital
1708 Filter (in some marginal cases (10%) times were reconstructed shifted
1709 by 0.2 slices)
1710
1711 - all executables now return 2 where in previous versions -1 has
1712 been returned (gave problems with shell-scripts)
1713
1714 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1715 also done with a intercalibration input file
1716
1717 - a bug in the time fine adjustment of the digital filter has been fixed
1718
1719 - a lot of small fixes to calling TPad::Divide with a margin==0
1720
1721 - MStatusDisplay now shows the memory usage
1722
1723 - added a memory leak statistic after the eventloop
1724
1725 - MHadronness replaced by MParameterD
1726
1727 - MEnergyEst replaced by MParameterD
1728
1729 - wobble mode can now be switched on from the data-set
1730
1731 - switched on bad pixel detection for a pedestal level
1732 which is more than 5 times the variance
1733
1734 - Fixed default paths to be correct for the new data center
1735
1736 - Fixed handling of drive data. The pointing position in now
1737 copied to MPointingPos inside star for real and MC events
1738
1739 - made sure, that the sequences in a dataset are sorted by
1740 their number to ensure the correct synchronization
1741
1742 - added all resource files necessary to handle spline extraction
1743 of signal for the late 2004 and the early 2005 data
1744
1745 - update the reference lines for the december data
1746
1747 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1748 This is important for the Dec. and Jan. data where the calibration
1749 pulse position changes much.
1750
1751 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1752 filter. This corrects only an defective extraction of the MC at
1753 low-gain signals lower than 90 phes.
1754
1755 - fixed some slowdown in calibrating data with interleaved events from
1756 Jan and Dec. As a workaround made the pretty palette the default.
1757 The inverse Deep Blue Sea has a bug which slows down long calibration
1758 runs a lot.
1759
1760 - implemented new values from new starguider report as defined
1761 in TDAS00-07 V7.1 (eg SkyBrighness)
1762
1763 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1764 in starguider report (If you merpp the same reports with this version
1765 you'll get the correct units (arcmin) but a different result
1766 than with old versions (wrong units))
1767
1768 - Now the status display can also write PNG, JPEG and XPM (other file
1769 formats are still unsupported by root)
1770
1771 - added a lot of scripts and macros in directory datacenter used
1772 for automatic processing
1773
1774
1775
1776 *** Version 0.9 (2005/03/23)
1777
1778 - Calibration is now done autmatically into photo-electrons like
1779 decided by the Collaboration Board
1780
1781 - Reference lines in the display can be read from resource file
1782
1783 - Interlaced calibration events can be handled by callisto
1784
1785 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1786 and applied in callisto.
1787
1788 - class MJCalibTest can be called by callisto
1789
1790 - callisto can now run with three data types: rawdata, rootdata, MC
1791
1792 - added two classes mreport/MReportStarguider.cc and
1793 mreport/MReportStarguider.h for implementing starguider-data
1794
1795 - the output of merpp-update now contains starguider information:
1796 MReportStarguider and MTimeStarguider
1797
1798 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1799 values were lower than they should. This was more visible for high
1800 energy (Size) events.
1801
1802 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1803
1804 - added a new loop to callisto to support the correct extraction of
1805 the pedestal and pedestal rms through the signal extractor
1806
1807 - added class to perform fourier tranformation of a hexagonal structure
1808 (MHexagonalFT)
1809
1810 - added class to perform fourier tranformation of a hexagonal structure
1811 in a tasklist (MHexagonalFTCalc) example: hft.C
1812
1813 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1814 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1815 small pixels, example: extendcam.C
1816
1817 - added possibility to write data to memory (TTree) using MWriteRootFile
1818
1819 - added possibility to read a TTree stored only in memory by MReadTree
1820
1821 - new classes to deal with the interleaved calibration events:
1822 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1823
1824 - implemented filters to callisto to skip calibration events
1825
1826 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1827 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1828 the slices by statistics
1829 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1830 signal extractor without randomization
1831 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1832 with the signal extractor with randomization (extraction window is
1833 randomly fixed)
1834 The three kind of pedestal is not yet implemented (for speed reasons) as
1835 long as nobody really needs it:
1836 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1837 extracted with the signal extractor with randomization
1838
1839 - callisto now finds the pulse position in the data automatically
1840
1841 - implemented data reduction in calibrated data by reducing the precision
1842 of the stored floating point values (pedestal, rms and signal) to
1843 roughly 0.5%
1844
1845 - fixed showplot to make file format conversion (eg. converting a
1846 status display stored in a root file into a postscript file) in
1847 batch mode possible:
1848 showplot -b --save-as-ps[=outfile.ps] infile.root
1849
1850 - Allow class names as part of filter rules, eg
1851 (MFSupercuts) && (MHillas.fSize>100)
1852
1853 - fixed a lot of stuff to allow all programs to process MonteCarlo
1854 camera files.
1855
1856 - enhanced possibility to debug reading of resource file
1857
1858 - MDataChain should handle priorities of operator more
1859 accurate now
1860
1861 - completely revised the container in which the signal is stored
1862 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1863 * the new implementation is faster and
1864 * needs less storage space
1865
1866 - FIRST version which can process Monte Carlos through the
1867 whole chain of programs (callisto, star, etc)
1868
1869 - implemented new image parameters for the border length of
1870 the shower image (MNewImagePar2)
1871
1872 - implemented wobble-mode in ganymed
1873
1874 - new class (MJOptimize) taking care of all optimization processes
1875
1876
1877
1878 *** Version 0.8.6 (2004/10/05)
1879
1880 - New combined signal and time extractor
1881 MExtractTimeAndChargeDigitalFilter
1882
1883 - The Report for the trigger section in the CC run summary has been
1884 updated, and now the IPRs (Individual Pixel Rates) are available.
1885
1886 - new macros for database interaction: filldotrun.C, filldotrbk.C
1887
1888 - added new program which can convert colored output which was redirected
1889 into a file back into colored text (for example to display it with
1890 more): showlog
1891
1892 - added new program to display an MStatusArray of plots (stored with
1893 MStatusDisplay) from a file: showplot
1894
1895 - Added support for Sequences (MSequence). Sequences are blocks of run
1896 files containing the same calibration and belonging to the same
1897 source
1898
1899 - Added a new task (MTaskEnv) which can be used in setup files to switch
1900 between different tasks (for example to choose a signal extractor)
1901
1902 - Implemented automatic file splitting in MWriteRootFile
1903
1904 - After image cleaning an island index is assigned to all used pixels.
1905 The index corresponds to the order of the islands in size.
1906
1907 - added a cleaning which takes signal height _and_ arrival time into
1908 account: probability cleaning (for more details see MImgCleanStd)
1909
1910 - added a cleaning which takes takes the absolute number of photons
1911 times the area ratio as cleaning level
1912 (for more details see MImgCleanStd)
1913
1914 - Changed calculation of image parameters such, that it can be done
1915 for all used pixels or the pixels with a defined island index only
1916
1917 - implemented new image parameters displaying the number of islands,
1918 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
1919
1920 - event display in executable changed to support also calibrated files
1921 (done with MJCalibrateSignal)
1922
1923 - added program doing the calibration and the signal extraction
1924 and signal calibration: callisto Most part of the setup is done
1925 by a resource file: callisto.rc
1926
1927 - implemented support for pixels with negative IDs (Raw file format
1928 version 4)
1929
1930 - implemented an new option in merpp (--auto-time) to get the time
1931 range for cc and/or caco data from the run header of the raw data
1932
1933 - New star-program (star and MJStar). Taking calibrated data from
1934 callisto/MJCalibrateSignal as input. The setup is done through
1935 a resource file: star.rc
1936
1937 - Added possibility to setup the eventloop in the mars-executable
1938 Camera Display by a resource file: mars.rc
1939
1940 - The the mars-executable Camera Display can now also read
1941 calibrated data files written by callisto/MJCalibrateSignal
1942
1943 - Added a new class which can calculate the source position in
1944 the camera from a pointing model known to be correct and
1945 the pointing model used for observations (MSrcPosFromModel)
1946
1947 - added a new version of the class calculating the effective on-time
1948 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
1949 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
1950 MHTimeDiffTheta.
1951
1952 - added the possibility to count how often a signal is above (or
1953 below) a certain threshold in MHCamEvent and MHCamEventRot (this
1954 can replace MHTriggerLvl0)
1955
1956 - added ore convinient ways to set the axis-titles of your histograms
1957 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
1958 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
1959
1960
1961
1962 *** Version 0.8.5 (2004/08/06)
1963
1964 - new Signal Extractors: MExtractFixedWindowSpline
1965 and MExtractAmplitudeSpline
1966
1967 - implementes interleave in merpp to be able to merpp parts of a file
1968
1969 - implemented force-functionality to merpp
1970
1971 - star display to display star catalogs (MAstroCatalog)
1972
1973 - star display to 'mirror' stars to the camera (MAstroCamera)
1974
1975 - implemented a new cleaning option which allows cleaning scaled with
1976 the real ratio of the rms depending on the pixel size, not only the
1977 square root of the pixelsize (MImgCleanStd, MCameraData)
1978
1979 - removed obsolete MBlind* classes
1980
1981 - Signal extractor taking the AB flag into account implemented (this makes
1982 an odd number of slices for signal extraction possible
1983 (MExtractSignalABcorr)
1984
1985 - implemented a class extracting the pedestal from the raw-data (events)
1986 itself using empty lo-gain (MpedCalcFromLoGain)
1987
1988 - Added mean values to MPedPhotCam
1989
1990 - Added Makefile for Darwin (this OS is NOT officially supported!)
1991
1992
1993
1994 *** Version 0.8.4 (2004/04/19)
1995
1996 - new fast arrival time extractor using cubic splines:
1997 MExtractTimeFastSpline
1998
1999 - implementes multi-argument support in MDataChain
2000 ("pow(a, b)")
2001
2002 - implemented double reference support in MDataChain
2003 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2004
2005 - added support in MF for expressiond like
2006 "MHillas.fWidth<2*<MHillas.fLength"
2007
2008 - MDataChain is now able to support variables like [0], [1], ...
2009 which can be used in fit functions as parameters. The interface
2010 is implemented through the new virtual function
2011 MParContainer::SetVariables
2012
2013 - added new class MArrivalTimeCam/MArrivalTimePix:
2014 Storage containers to hold the ArrivalTime of the camera/pixel
2015
2016 - added new classes for the calibration of relative arrival times:
2017 MCalibrationRelTimePix and MCalibrationRelTimeCam
2018
2019 - added new classes to extract the signal of the blind pixel and the
2020 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2021
2022 - added new classes for the bad-pixels treatment (MBadPixels*)
2023 which are more powerfull than the old ones (MBlindPixel*)
2024 and will replace them.
2025
2026 - added filter against cosmics: MFCosmics
2027
2028 - added new class MArrivalTimeCalc2:
2029 Calculates the arrival time as the signal weighted mean of the time
2030 slices in the maximum window
2031
2032 - added a new macro call pointspreadfucntion.C that fits with a 2D
2033 gaussian the DC spot for an star. It gives you the RMS of
2034 the PSF and the center of the star, very useful for misspointing
2035 studies.
2036
2037 - added support for multi-telescope camera files. Added classes
2038 MStereoCalc and MStereoPar, classes to calculate and store shower
2039 parameters calculated from the data of two telescopes, for the MC
2040 studies regarding the MAGIC clone.
2041
2042 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2043 MC data calibrated in photons instead of ADC counts.
2044
2045 - added three macros to show the calibration and analysis chain of
2046 MC data. The macro starmc.C does both calibration and analysis, producing
2047 an output containing Hillas parameters for each event. The macro
2048 mccalibrate.C does just the calibration and writes out a file containing
2049 pixel information in photons instead of FADC data. The macro starmc2.C
2050 reads in such a file and produces an output with Hillas parameters.
2051
2052 - added MPedPhotCalc to compute pedestals in units of photons, see
2053 macro pedphotcalc.C
2054
2055 - added all class to perform the calibration, see macro calibration.C
2056
2057 - added class MFFT to perform Fast Fourier Transforms
2058
2059 - added class MSimulatedAnnealing to perform simulated annealing
2060 minimizations
2061
2062 - added new macro bootcampstandardanalysis.C which holds the skeleton
2063 of the analysis chain discussed in the december bootcamp.
2064
2065 - added support for DAQ raw data file format V2
2066
2067 - implemented an arbitrary time stamp for the events from raw-data
2068 files with file version<3. It is calculated from the run number,
2069 the date of start and the FADC clock tick from the first module
2070
2071 - implemented the correct decoding of the event time-stamp
2072 coming from the DAQ for raw-data files with file-version>2
2073
2074 - added a new classes storing the pedestals in units of photons:
2075 MPedPhotPix, MPedPhotCam
2076
2077 - added support for DC current files from the camera control
2078
2079 - added support for start- and stop-time when merpping report files
2080
2081 - added MReportCC storing the weather data from the CC-REPORT
2082
2083 - added class to fill trainings and test matrices (MTFillMatrix)
2084
2085 - added a filter performing a software trigger (MFSoftwareTrigger)
2086
2087 - Added classes to perform parts of the standard analysis (Jobs):
2088 + MJPedestals
2089 + MJCalibration
2090 + MJExtractSignal
2091 Note: All of them are preliminary!
2092
2093 - Added Iterator to iterate over files giving only the run-number
2094
2095 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2096 the evolution of a sector vs time
2097
2098
2099
2100 *** Version 0.8.3 (2003/12/05)
2101
2102 - adapted Random Forest classes to allow the use with MC
2103 multi-telescope files which can be produced with the coming
2104 camera version 0.7.
2105
2106 - added classes to read and interprete central control report files
2107 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2108
2109 - enhanced merpp (the executable) to support .raw and .rep files.
2110
2111 - added classes for light calibration (MCalibration* and
2112 MHCalibration*) by Markus Gaug. Further work has to be and will
2113 be done soon.
2114
2115 - Added a preliminary 'synchronizer' (MReadReports) which will
2116 replace MReadMarsFile as soon as it is finished.
2117
2118 - Added a tutorial macro demonstrating how report files are merpped
2119 and how they can be read from the root file in the correct order
2120 of time (readrep.C)
2121
2122 - Added a generalized histogram (similar to MH3) called MVsTime
2123 which allows to plot variables (or rules - MDataChain - of
2124 variables) vs time. For an example have a look at tempvstime.C.
2125
2126 - Changed the name of the event trees:
2127 + Events --> Events
2128 + PedEvents --> Pedestals
2129 + CalEvents --> Calibration
2130
2131 - changed name of MTime in the event trees from MRawEvtTime to MTime
2132
2133 - added displaying the sector indices to the mars event display
2134
2135 - Magic Online Analysis (MOnA) implemented in a first version
2136 (see mona.cc, MOnlineDump and MOnlineDisplay)
2137
2138 - added classes to calculate event rate
2139 (preliminary: MEventRateCalc, MEventRate)
2140
2141 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2142
2143 - added classes dealing with the telescope pointing position (MPointing*)
2144
2145 - implemented the 'final' Mars time stamp based on some experiences with
2146 the new 'Synchonizer'
2147
2148
2149
2150 *** Version 0.8.2 (2003/11/10)
2151
2152 - accelerated standard analysis by a factor of 6-8 ...
2153 + doing precalculations in MGeomCam for the pixel area ratio
2154 + creating a look up table for the single pixels in MCerPhotEvt
2155
2156 - added task to calculates weights in case you want to 'change'
2157 the energy spectrum of a monte carlo file
2158 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2159
2160 - added a new executable star which implements the
2161 star.C macro as precompiled executable. Currently a flexible
2162 setup is not possible, but a 'input card' setup will follow.
2163
2164 - Starting to implement Multi-Telescope-Support based on the
2165 upcomming camera version 0.7. The base for a general support
2166 is implemented and the star-functionality is proven to work.
2167
2168 - Replaced Event-Display in and Camera-Display in the Mars GUI
2169 executable by a more convinient display base on MStatusDisplay.
2170
2171 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2172
2173
2174
2175 *** Version 0.8.1 (2003/10/20)
2176
2177 - added signal subtraction for pure on data by means of fitting
2178 the background in the off region or by performing a combined
2179 signal/background fit. Provides necessary histograms for
2180 obtaining energy spectra and a light curve.
2181
2182 - added classes to perform and study the selection of the
2183 2nd Level Trigger on MC data (example in triglvl2.C macro)
2184
2185 - added pedestal calculation
2186
2187 - implemented "democratic cleaning" (tail cut value proportional
2188 to pixel area) according to Wolfgang's suggestion.
2189
2190 - added Sigmabar treatment (calculation and basic histogramming)
2191
2192 - added basic routines to apply padding
2193
2194 - added first implementation of MARS-based source visibility plotter
2195 (needs to be linked against slalib, preliminary version)
2196
2197 - enhanced functionality of data chains: random numbers, conversion
2198 functions and access to MHMatrix objects
2199
2200 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2201 numbers under certain circumstances (runs with 0 events included)
2202
2203 - fixed a bug in the general filter MF (didn't work on some systems
2204 at all)
2205
2206 - fixed a bug in chaining files, which caused the analysis to crash or
2207 ignore files
2208
2209 - implemented more geometry classes describing the parameters used
2210 to simulate the PMT camera
2211
2212 - added new Monte Carlo classes containing the setup of the different
2213 programs in the MC chain.
2214
2215 - added a (preliminary) general task to evaluate chi-square of a given
2216 parameter in an eventloop.
2217
2218 - first implementation of a container describing the observatory
2219 location (Long, Lat, etc)
2220
2221 - added Random Forest - method for g/h-separation
2222
2223 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2224 (this means, that it is compiling, but not yet fully tested)
2225
2226 - added a new status display which can show the present status
2227 of histograms while an eventloop is running (MStatusDisplay,
2228 an example can be found at status.C)
2229
2230 - reorganized directories:
2231 classes describing the image --> mimage
2232 classes containing Monte Carlo Histograms --> mhistmc
2233 classes for Random Forest method --> mranforest
2234
2235 - added (event-)weights to fill histograms
2236
2237 - colors in logging output to screen
2238
2239 - changes to the Image Parameter declaration:
2240 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2241 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2242 + MHillasExt now derives from MParContainer instead of MHillas
2243 --> Files written with the old definition are more or less unreadable
2244
2245 - reading of reflector files
2246
2247 - display data from reflector files in the camera
2248
2249 - implemented currents (and display them in the camera)
2250
2251 - logarithmic scale in camera
2252
2253 - added class to iterate through directory contents (MDirIter)
2254
2255
2256
2257 *** Version 0.8 (2002/11/18)
2258
2259 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2260
2261 - corrected 48(!) wrong entries in the Next Neighbor table of the
2262 Magic Camera (all in the inner part of the outer ring, mostly
2263 missing a single NN)
2264
2265 - Fixed a bug in the table describing the Next Neighbours of the
2266 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2267 have any neighbour)
2268
2269 - changed trigrate.C: now it calculates the pure NSB triggers from
2270 a camera file (generated with no showers), so there is no need
2271 to introduce them by hand in the BgR array (for more details
2272 please ask Abelardo)
2273
2274 - added MHHadronness (and MHadronness) as a general facility to evaluate
2275 the quality of a gamma-hadron seperation method
2276
2277 - changed MWriteAsciiFile to accept rules (MDataChain)
2278
2279 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2280 must be replaced by calles to MWriteAsciiFile::AddColumn and
2281 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2282 changed.
2283
2284 - Implemented generalized event-matrices (one row per event)
2285 (MHMatrix)
2286
2287 - implemented the one dimensional composite probabilities
2288 (MHCompProb, MCompProbCalc, comprob.C)
2289
2290 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2291 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2292
2293 - Added a camera display displaying the pixel numbers to the
2294 event display gui.
2295
2296 - Added Monte Carlo Informations to event display gui
2297
2298 - Changed the camera display to display the pixel numbering
2299
2300 - Added three buttons to the camera display to change the palette
2301
2302 - Added the number of used and core pixels after image cleaning
2303 to MHillas
2304
2305 - Changed the algorithm used in MHillas according to TDAS 02-03
2306
2307 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2308
2309 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2310
2311 - Added fCosDeltaAlpha to MHillasSrc
2312
2313 - The numbers of photons used to calculate fConc and fConc1 in
2314 MHillasExt are now scaled with the pixel size, so that one get
2315 a four times smaller value for the bigger pixels in the outer ring.
2316
2317 - added new task to smooth the camera contents (MCameraSmooth)
2318
2319 - added possibility to use interpolated pixel values for blind pixels
2320 instead of removing it completely from the analysis
2321
2322 - Implemented the possibility to save the whole eventloop with
2323 its setup to a file. This information can be read and from
2324 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2325 and MEvtLoop::MakeMacro. If you find something not working, please
2326 report - this stuff is still in a beta phase.
2327
2328 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2329 file having crab starfield, but also for all following files - fixed
2330
2331 - MTaskList::PrintStatistics can now be instructud to print also the
2332 title, too: use PrintStatistics(0, kTRUE)
2333
2334 - Changed the image cleaning so that pixels with to many 'used'
2335 neighbors are left used (to get rid of 'holes' in events)
2336
2337 - Introduced more output to the camera displays
2338
2339 - Added an array of histograms (eg one hist per run), MHArray
2340
2341 - Added a _preliminary_ version of the reader for CT1 PreProc files
2342 (MCT1ReadPreProc)
2343
2344 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2345 (thanks to Raquel)
2346
2347 - added the first energy estimator (MEnergyEstParam, estimate.C,
2348 estfit.C) using a parametrization
2349
2350 - Added some new Monte Carlo paremeter containers used to store
2351 setup information from the MC chain (MMcConfigRunHeader,
2352 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2353
2354
2355
2356 *** Version 0.7 (2002/04/30)
2357
2358 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2359 the pedestal mean value was saved incorrectly. For files from
2360 this versions we substract 0.5 from the pedestal mean.
2361 WARNING: This may effect your results, so don't wonder...
2362
2363 - First implementation of an algorithm using only triggered events
2364 for the collection area calculation
2365
2366 - Ascii Output can now also be used for parameter containers which
2367 doesn't overload MParCointainer::AsciiWrite
2368
2369 - The Ascii Output is now also capable of writing single data members
2370 of one container
2371
2372 - You are now able to change the order of the values written to the
2373 ascii file
2374
2375 - You can now specify a conversion factor for each data member written
2376 to an ascii file. This may be usefull to change the units of the
2377 data member (eg. degrees instead of millimeters in case of the
2378 hillas parameters)
2379
2380 - Replaced old MHillas by a new structure which allows you to extend
2381 the parameters stored in MHillas very easily:
2382 see MHillas and MHillasExt
2383
2384 - Added classes to handle source dependancy of image parameters:
2385 see MHillasSrc
2386
2387 - Added container (MBinning) to have a standard input for the binning
2388 in different histograms (eg. the Energy bins should be the same in
2389 all histograms)
2390
2391 - Changed Hillas histograms from mm to deg
2392
2393 - Added the flexible binning to the hillas histograms
2394
2395 - Added a filter for the alpha parameter (MFAlpha)
2396
2397 - It is now possible to write single data members of a class object to
2398 an output stream instead of the whole container only
2399
2400 - Added a generalized filter for a data member:
2401 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2402
2403 - Added a generalized Filter parser for more difficult filter rules
2404 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2405
2406 - Added new Monte Carlo histograms:
2407 MHMcEnergyImpact and MHMcEfficiency
2408
2409 - Added many new histograms needed for the flux calculation.
2410
2411 - Added a generalized histograms which can fill and show up to three
2412 data members in either a one-, two- or three-dimensional histogram, eg:
2413 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2414
2415 - Added:
2416 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2417 * calculation of <Theta> as a function of time (MHThetabarTime)
2418 they are needed in the flux calculation in
2419 order to select for a given bin in Theta (or time) the appropriate
2420 effective collection area, which is assumed to be given as a function
2421 of Theta and the true energy
2422
2423 - Added calculation of the migration matrix in the energy
2424 (MHMcEnergyMigration):
2425 the migration matrix describes the migration from the true (E_true)
2426 to the estimated energy (E_est); it is needed to determine the
2427 distribution of E_true from the measured distribution of E_est
2428 by unfolding
2429
2430 - changed the color palette in the camera display to DeapSea.
2431
2432
2433
2434 *** Version 0.6 (2002/01/15)
2435
2436 - Introduce the option of disable pixels (MBlindPixels and
2437 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2438 able to deal with Star Field NSB.
2439
2440 - Fixed a bug in the pedestals substraction
2441
2442 - Introduced verbosity levels
2443
2444 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2445
2446 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2447 work correctly (thanks to Abelardo)
2448
2449 - Introduced correct treatment of the diffuse Night Sky Background
2450 and NSB (MMcPedestalNSB)
2451
2452 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2453
2454 - Introduced MMcRunHeaders which contains monte carlo run informations
2455
2456 - Added a 'Print'-Task (MPrint) which calls the Print function
2457 of a parameter container for each event
2458
2459 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2460
2461 - changes to be more efficient with root 3.02/06
2462
2463 - root 3.02/06 fixes:
2464 + the memory leak when reading MRawEvtData
2465 + loosing more time than necessary to update the progress bar
2466
2467 - MWriteAsciiFile is now capable of writing more than one container
2468 in a line. For example: To be able to write Monte Carlo and
2469 Hillas values (energy and alpha) in one line.
2470
2471
2472
2473 *** Version 0.5 (2001/11/06)
2474
2475 - Added new GUI functionality (Analysis)
2476
2477 - Added a camera display to be able to display events in the camera
2478 together with the calculated hillas ellipse
2479
2480 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2481 object at any state of the analysis, so that the output are several
2482 states
2483
2484 - Fixed a bug in the collection area error calculation
2485 (Thanks to Ciro and Abelardo)
2486
2487 - Fixed a bug which causes merpp to crash in some environments
2488
2489 - Implemented auto enabling scheme for Branches to speed up reading
2490 a lot (see MReadTree and MTask)
2491
2492 - Fixed a bug in the Histogram classes which caused histograms to
2493 be written to a file by MWriteRootFile without request
2494
2495 - changed the object I/O from the old stylish root I/O to the new
2496 'auto evolution scheme' This was done only for classes which are not
2497 yet used in Monte Carlo files, so that these files are still readable.
2498
2499 - Added support for a progress bar in MEvtLoop and MReadTree
2500 (see the Analysis Window in Mars for an example)
2501
2502 - Fixed a bug in the package creation which disturbed the conversion
2503 between a mars version unpacked from a tar file and the repository.
2504
2505 - Changed the code to writer merpped (converted into root format)
2506 raw files, to get faster (around 10%)
2507
2508
2509
2510 *** Version 0.4 (2001/09/20)
2511
2512 - This release is made to compile on a root version >= 3.00
2513
2514 - Fixed a bug which causes MReadTree to read the first file only
2515
2516 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2517
2518 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2519
2520 - Added a task to write several container to a root file (MWriteRootFile)
2521
2522 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2523
2524 - Added calculation of the collection area (MMcCollectionAreaCalc)
2525
2526 - fixed some bugs in the Hillas calculation
2527
2528 - added filters to be able to control the task execution dependent on
2529 a parameter (for example: the number of level 1 triggers in a MC-file)
2530
2531
2532
2533 *** Version 0.3 (2001/04/23)
2534
2535 - Many demo macros added
2536
2537 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2538
2539 - Hillas Calculation added
2540
2541 - Standard image cleaning available
2542
2543 - MReadTree is now able to handle more than one file
2544 (Remark: of the same structure)
2545
2546 - Now we are able to display events in a first version of the
2547 Camera event display. To do this we must run the macro
2548 "macros/readCT1.C" to read data from CT1.
2549
2550
2551
2552 *** Version 0.2 (2001/01/24)
2553
2554 - First Implementation of a Gui to read the raw data. Start the
2555 gui with the command mars.
2556
2557
2558
2559 *** Version 0.1 (2000/12/20)
2560
2561 - First official release 0.1
2562
2563 - Changes:
2564
2565 + changed calling style of MRawPixelIterator from do...while to
2566 while-loop
Note: See TracBrowser for help on using the repository browser.