source: trunk/MagicSoft/Mars/NEWS@ 8785

Last change on this file since 8785 was 8780, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 112.1 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5;general
6* fixed GroupBy options in plot*.C macros
7* only display KVA points (not the Tuorla points) in plotoptical.C
8* all programs now allow to add resources to the ones from the resource
9file or overwrite them from the command line. This can be done like this
10::ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
11:if something seems to be wrong you can debug what the program is doing
12using the option --debug-env=3
13* increased the diversity of debug levels. That also means that with -v3
14you get now less output, i.e. only the output which is important for
15an analysis. To get more output which helps for debugging try 4, 5 and 6.
16* fixed a problem in the task synchronizing the reading of the reports
17and the data stream. The effect was that in some circumstances the last
18events of some trees could have been skipped. Since this is only a
19very tiny part of the data no severe effect to your analysis results
20is expected.
21* Dataset file now allow to include the sequence file directly within
22the dataset file and also allow to exclude single runs from the dataset.
23(for more details see Class reference of MDataSet)
24* Sequence files now allow for excluding runs from the analysis
25(for more details see Class reference of MSequence)
26;ganymed/sponde
27* Now data points are even shown correctly if they have error bars larger
28than one sigma. Points with null or negative significances are omitted.
29;sponde
30*fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
31
32
33 *** Version 2.0 (2007/09/03)
34
35 - database: the position used for the pulse pos check was missing
36 in the callisto output and could thus not be filled into the DB.
37 Also the old values seemed not exactly the PulsePos used for
38 teh check.
39
40 - general: Resource file now allow an Include-Resource, i.e. you can
41 read a resource file with default settings, include it in your
42 resource file and overwrite the settings in your file. More than
43 one include file is allowed. Inclusions can be iterative.
44 Include: mydefaults.rc yourdefaults.rc
45 The resources in the first file have higher priority than the
46 second file.
47
48 - general: Now the output files (calib*.root, etc) also contain the
49 resource file (to check it open it in the TBrowser and choose Print()
50 from the context menu)
51
52 - general: Dataset files now allow to overwrite the default path
53 to search for sequence and data files. Note, that the program
54 option and individual resources will overwrite it. For example:
55 SequencePath: /magic/montecarlo/sequences
56 DataPath: /magic/montecarlo/star
57
58 - general: Fixed a problem with variables in MDataPhrase. It seems
59 that only optimdisp (didn't work) was effected.
60
61 - general: Some improvements to the optim and train processing. For
62 example the ststud window now got a proper title.
63
64 - general: The "Status Display: " was removed from the window title
65 within an Eventloop.
66
67 - general: added a new flexible histogram-class (MHn) which can be used
68 for example in testing after optimizations or training to produce
69 user defined histograms.
70
71 - general: The Random Forest now allows attaching an evaluation
72 function which is applied to its output. This allows to train
73 on whatever you like (eg. train on log10(energy), but return
74 energy)
75
76 - general: The Random Forest training of energy (trainenergy.c) and
77 disp (traindisp.C) has been improved by more graphical output to
78 judge the result.
79
80 - general: The training of energy (trainenergy.C) has been improved
81 a lot by training on a different quantity than energy. It gives
82 a result which is highly independant of the source spectrum
83 and shows lower bias than all other options.
84
85 - general: Dataset files are allowed to contain collections of
86 datasets. For more details see the class reference of MDataSet.
87
88 - general: The default WobbleMode in a datset file now (if not
89 overwritten) is "auto", i.e. wobble mode is set if the dataset
90 doesn't contain off-sequences.
91
92 - merpp: Merpp can read file format version 9 now. Please realize
93 that for file format version 9 the extraction range is different
94 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
95 the first and last 15 slices have been removed from all MUX data.
96
97 - mars: Similar to writing movies you can now select events which
98 should be displayed in your display. Therefore add the following
99 lines to your mars.rc:
100 MFEvtNumber.FileName: ganymed00223552.root
101 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
102 The input file can be a ganymed-file after (ganymed*.root) or
103 before (ganymed*-summary.root) file. For example to select all events
104 from your on sample after cuts (excluding the ThetaSq cut) use
105 MFEvtNumber.Selector: DataType.fVal>0.5
106 To show all events from your on-sample after quality cuts
107 use the summary file instead.
108
109 - mars: new ways to call mars are implemented. Instead
110 of calling
111 mars filename.root
112 you can now also use
113 mars sequence.txt
114 or
115 mars sequence.txt inputpath
116 or replace sequence.txt by the sequence number if the default
117 sequence file should be used.
118
119 - mars: The default size has been increased
120
121 - mars: There are two new heckboxes which allow to switch off
122 the calculated image parameters
123
124 - callisto: was broken for MCs... fixed.
125
126 - callisto: improved calculation of spline coefficients a lot. This
127 leads to a further improvement of the event rate calibrating MUX
128 data of about 15% (175evt/s instead of 150evt/s)
129
130 - callisto: finally the raw data we read is now real 16bit (with
131 10bit precision) for MUX data and not a stripped 8bit number
132 anymore. Due to scaling of the numbers (without precision loss
133 into an [0-256[ range, the final numbers for pedestal, pedestalrms
134 and extacted signal don't change. However, at all places where
135 raw data is directly accessed (eg. saturation and variation
136 limits in the signal- and pedestal-extraction) the numbers
137 refer still to the data's 16bit range.
138
139 - callisto: The maximum arrival time difference used in the bad
140 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
141 for both, old FADC and MUX-FADC, data.
142
143 - callisto: Be aware that callisto is now calibrating the arrival time
144 in nanoseconds rather than time slices. Also all following tasks
145 have been changed to assume ns units now. If you star data
146 calibrated with an older version it might be necessary to adapt
147 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
148 to obtain optimal results. The plot in the PulsePos tab
149 will now be in ns, too. This might also mean that the Muon
150 analysis in star might not work as perfect as expected as long
151 as old files read in.
152
153 - callisto: The calibration constants of earlier updates got lost
154 somehow. All constants have been updated.
155
156 - star: The PSF is now determined from the profile of the ArcWidth
157 instead of arcwidth/radius. The old way gave to much weight
158 to the bins with low statistics. The reference lines have been
159 updated.
160
161 - star: For speed reasons events suitable for the muon analysis
162 are now also preselected by fConcCOG<0.1 which seems to be a very
163 good preselector for muons.
164
165 - star: is now calculating a new timing parameter the Slope along
166 the major and minor axis of the shower. Therefore a numerical
167 solution of a line-fit is used. To use MHillasExt.fSlopeLong
168 and MHillasExt.fSlopeTrans don't forget to multiply it with
169 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
170
171 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
172 have been removed from MNewImagePar. They have never been good for
173 anything.
174
175 - star: Implemented a new recursive algorithm which is supposed to be
176 faster. Also implemented new cleaning oiptions, which are:
177 + CleanLevel0:
178 The cleaning level above single core pixels can be kept
179 + KeepIsolatedPixels:
180 Define whether single core pixels should be kept
181 + TimeLevel1:
182 The coincidence window in nanoseconds to single used neighbors
183 + TimeLevel2:
184 The coincidence window in nanoseconds to two used neighbors
185 + PostCleanType:
186 MOde in which a time dependent post cleaning should be applied
187 0: No post cleaning
188 1: Require for each used pixels at least one used neighbor
189 within a time-window of CleanLevel1
190 2: Require for each used pixels at least two used neighbor
191 within a time-window of CleanLevel2
192 3: Require first two and second one used neighbor
193 within a time-window of CleanLevel1 and fCleanLevel2
194 respectively
195 + RecoverIsolatedPixels:
196 - recoveres isolated core pixels if they have a used neighbor
197
198 - mars/star: The new default cleaning is:
199 + CleanLevel1: 6.0
200 + CleanLevel2: 3.0
201 + CleanTime1: 1.75
202 + CleanTime2: 1.75
203 + PostCleanType: 3
204
205 - star/ganymed: The old spark-cuts have been replaced by new ones.
206 These new spark cuts have been cross checked with the sequences
207 84720 (before splitter), 101041 (after splitter) and 223539 (new
208 FADCs). In all cases they seperate pretty well, but of course not
209 perfect. Monte Carlos have suggested to tighten the cuts a little
210 bit further at low sizes. This has been done.
211
212 - ganymed: IMPORTANT - The spark cuts have been changed to match
213 all available data more or less well. This might mean that for
214 YOUR data there are still sparks visible.
215 Whenever you do an analysis you have to make sure that NO sparks
216 survive your cuts!
217
218 - ganymed: The old hadronness and size cuts have gotten new indices
219 (10, 11). The old indices 8 and 9 now mean an additional condition
220 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
221 If you want to switch off this cut just move the line far away enough,
222 e.g. by setting c[9] to -500. Please update your ganymed.rc files
223 accordingly!
224 The unit of c[9] is deg. It is the dist at which your cut will
225 cross the slope==0. The unit of the slope is ns/deg. So if
226 you readin files calibrated with an older Mars-version you
227 have to adapt the default value for c[9] to the FADCs:
228 - Multiply by two for the MUX FADCs (run number > 200.000)
229 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
230 - Multiply by 42 for the meaning of life (run number = 200.000)
231
232 - ganymed: The old Cut0 is now called CutQ and is calculated before
233 the source position is caluclated. If you need a quality cut
234 including source dependant data (be very carefull with this!)
235 you have to use Cut0 instead.
236
237 - ganymed: now properly supports three off regions in wobble mode.
238 It will be the default from now on in ganymed_wobble.rc. To change
239 the number of off-regions use
240 NumOffSourcePositions: 1
241 in your ganymed.rc. Also by default no off-theta cut will be done
242 anymore so that you will get a background level higher than the
243 signal level in your ThetaSq plot for ThetaSq>0.2.
244 Due to this be carefull changing the scaling mode away from
245 "None". You will underestimate your signal if your scale interval
246 is not properly set.
247 (Rem: ThetaSqN is no longer needed)
248
249 - ganymed: is now storing the events of all (on- and off-)
250 source positions even in the case of more than one off-source
251 position. This should allow sponde to work properly and the
252 energy estimation is done correctly in all cases (without any
253 "nearest position" trick)
254
255 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
256 with a real pointing model for the starguider is done, calibrated
257 with more than thousand tpoints taken from this date on.
258
259 - ganymed: was broken for Wobble-MCs... fixed.
260
261 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
262 has changed. Note that your old ganymed.rc will be incompatible
263 with the new algorithms! Please check the ganymed.rc files and
264 the class description of MFMagicCuts for more information.
265 It is recommended at the moment to use identical Disp-Parametrizations
266 for on/off- and wobble-mode. If cuts are optimized only
267 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
268 should be optimized. All other values should be kept as they are.
269 If you want to do an anylsis without timing a parameters, you can
270 switch off the timing cuts by seeting parameter 7 to a very small
271 value (eg. -99). To remove the slope parameter from the disp
272 paremtrization set parameter 8 to 0.
273
274 - ganymed: The distribution of observation time versus zenith
275 angle is now shown for off- AND on-data.
276
277 - ganymed: The contents of the source position plot are no longer
278 averaged, thus a lot of (fake) events between the two wobble
279 positions have disappeared.
280
281 - ganymed: There is a new tab "CutT" it contains the VsSize plots
282 with the CutT, whihc is defined in ganymed.rc, applied. It
283 is resonable to use your theta-cut for it, to see if there is
284 something strange (sparks!) in your signal-region.
285
286 - ganymed: To choose a dataset from a collection in a dataset file
287 use the new command line option "--dataset=12345"
288
289 - optim, sponde: should now properly support three off-regions.
290 Just produce your ganymed summary files with three off-regions.
291 optim and sponde will automatically get all off events from
292 all off-regions from this file. Please do not forget to
293 set the scaling in optimwobble.C properly:
294 fit.SetScaleUser(1./3);
295 it is not yet read in automatically (will follow soon).
296 In the case of fixed Scale you can also use
297 cuts.SetThetaCut(MFMagicCuts::kOn);
298 no off-cut needed.
299 Be carefull in case of three off-regions when switching on
300 scale mode. Make sure that the scale interval is set correctly.
301
302 - sponde: sponde.rc and sponde_onoff.rc are now idetical
303
304 - sponde: the resouce files have been rewritten with a lot of
305 comments and a well working parametrization for an energy estimator
306
307 - sponde: In the estimated energy versus monte carlo energy plot the
308 contents where exchanged.... fixed.
309
310 - sponde: the so called "accurate"-mode has been removed. It didn't
311 give any improvement in accuracy, only decreased execution speed.
312
313 - sponde: the so called "simple"-mode has been removed. It didn't
314 give any improvement in simple.
315
316 - sponde: the so called "refill"-mode has been removed. It was anyhow
317 not implemented.
318
319 - sponde: now checks whether the theta distribution of your on-data
320 and the theta-distribution of your Monte Carlo sample (after
321 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
322 sample is incomplete) execution is stopped. Execution can be forced
323 using the new option --force-theta. Use this option with care!
324
325 - sponde: Proper collection areas can now be constructed also from
326 Monte Carlo samples generated with different maximum impact
327 parameters. Note that in previous version you neither got
328 a warning or failure, nor was there any obvious sign that the
329 collection area was overestimated due to usage of files with
330 different maximum impact parameters.
331
332 - sponde: If MC files with different lower energy limits are used
333 the primary MC spectrum is artificially completed down to the
334 lowest energy used at all. WARNING: that this gives correct
335 collection areas ONLY if none of the events in this region would
336 survive your cuts at all.
337
338 - sponde: the output file now contains more information about
339 the spectrum (eg. the full 2D collection area histogram).
340 Note, that this information can only be written to the file
341 if it is stored automatically via command line argument.
342 If you only store the status display from within the display
343 the information is lost.
344
345 - sponde: added a new tab "Disp". It shows the residual of the disp
346 (Disp-Dist) versus several parameters and it is meant to judge the
347 quality of the disp estimator. In the ideal case the residual is zero
348 and doesn't depend on any variable. The tab is displayed after
349 CutQ and Cut0.
350
351 - sponde: added a new tab "Energy". It shows the residual of the
352 energy (lg(estimated energy)-lg(monte carlo energy)) versus
353 several parameters and it is meant to judge the quality of the
354 energy estimator. In the ideal case the residual is zero
355 and doesn't depend on any variable. In reality even a good estimator
356 can show residuals versus Monte Carlo energy. The tab is displayed
357 after all cuts.
358
359 - sponde: added a new tab "EventDist" showing the unweighted real
360 absolute number of events of your sample after cuts. This tells
361 you how many events with this energy you had in your MC files.
362 The same information you get from the error bars of the weighted
363 histograms, but this is less intuitive.
364
365 - sponde: The spectrum plots now show the crab- and 1553-spectrum
366 for comparison. It is not meant to show these curves in
367 publications, they are only for production.
368
369 - sponde: The OriginalMC tree with the events produced by corsika
370 is now processed only once
371
372 - sponde: Finally fixed most annoying bug, which has effected the
373 last bin of the collection area. It was the problem that binnings
374 of root histograms are from 1 to n (included) but there was a C-like
375 loop in sponde from 0 to n (excluded). Now the loop also includes
376 correctly under- and overflow-bins. The worse thing with this is,
377 that for the events in the highest bin not only the bin-content
378 was wrong, but also the weights applied to these events, which could
379 in pricipal effect also other parts of the distribution (eg. due
380 to energy estimation). Fortunately it effected only a few events
381 in most cases.
382
383
384
385 *** Version 1.2 (2007/05/14)
386
387 - database: The database now has two new values Unsuitable50 and
388 Unsuitable01. They express the number of pixels which are
389 unsuitable for more than 50%, respectively more than 1%, of
390 all calibrated event. It is a more accurate number than the
391 previously used numbers, because they only take the first
392 calibration (ignoring the interleaved calibrations) into account.
393
394 - database: The database now has two other new values UnsuitableMax and
395 DeadMax. They express the maximum number of pixels which were
396 unsuitable, respectively dead, during the sequence. Because
397 of high pedestal rms (cars passing) a few events with very high
398 numbers of unsuitable pixels can happen. Not to suffer from this
399 effect we don't take the highest 0.1% of the numbers into account.
400
401 - general: fixed a bug which caused callisto and star to stop working
402 properly because the callisto output was currupted
403
404 - general: a script called scripts/makemovie has been added which
405 simplified the process of producing several movies from a single
406 sequence with different setup.
407
408 - callisto: Some more code cleanup. Started to remove old obsolete
409 code from cvs.
410
411 - callisto: The extraction of the pedestal with the extractor was
412 not random. It seems that extracting at one position is still biased
413 (for example in the first or last slices we could still suffer from
414 switching noise) Now it is completely random.
415
416 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
417 pedestal files) individual pixels could be skipped due to high
418 variations. This was already the case for the pedestal extraction
419 from the lo-gains since the beginning and properly handled
420 there, but was introduced in the extraction from the pedestal files
421 a while ago. To calculate the average value it was still divided
422 by the number of events procesed not by the number of summands
423 really summed. This let to a pedestal which was a tiny amount too
424 small (for a few piels in the order of 0.1%). This led to an slightly
425 positive offset of the randomly extracted pedestal for a few pixels.
426 I doubt that this has a big effect on the result, because the effect
427 on the individual numbers is quite small. Due to this it is suggested
428 that you rerun your calibration to make sure you are without any
429 avoidable bias.
430
431 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
432 the median rms of the absolute arrival time and expressed in significance
433 levels. This replaces the old meaning of an abolute upper limit. An
434 absolute upper limit doesn't make much sense, because in our data
435 all arrival times are shifted at the same time (in fact it might be
436 a shift of the artificial trigger w.r.t. to the light flash).
437
438 - callisto: Added a new tab "BadPixTm" which shows the time evolution
439 of the number of unsuitable pixels over the whole sequence. This
440 is usefull mainly to judge if an intermediate calibration had
441 problems.
442
443 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
444 of the number of dead pixels over the whole sequence. Dead pixels
445 in this context are unmapped pixels, i.e. pixels which could not
446 be interpolated, and thus are ignored in the further analysis.
447
448 - callisto: It is now possible to use the position of the maximum
449 of the spline as arrival time instead of the leading edge even
450 when using the integral for the signal. Therefor set the extraction
451 type to kIntegralRel ("IntegralRelative") and the relative height
452 ("HeightTm") to -1:
453 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
454 MJPedestalC1.ExtractSignal.HeightTm: -1
455
456
457
458
459 *** Version 1.1 (2007/04/27)
460
461 - general: The new class MGeomCamDwarf contains the camera geometry
462 for our prefered Dwarf camera and can be used to create general
463 geometries of roundish or hexagonal cameras.
464
465 - mars: The default cleaning is now abolute 8.5/4.0.
466
467 - mars: The resource file mars.rc now contains examples for MUX data
468
469 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
470 data containing only 10-bit information is still cooked down to
471 8-bit, by cutting away the lowest 8-bit.
472
473 - merpp: When reading raw data the data is now stored in a single
474 array. The lo-gain array is obsolete. The interface stays the same.
475
476 - callisto: To process the new MUX data use the resource file
477 callisto_mux.rc
478
479 - callisto: The -root and -raw options to read merpped raw data have
480 been removed
481
482 - callisto: If the -mc option is given the sequence-name can now be
483 replaced by the MC sequence number
484
485 - callisto: If the sequence file contains "MonteCarlo: Yes" the
486 -mc option can now be omitted
487
488 - callisto: Started further simplification by removing obsolete
489 dependancies on MCalibIntensity*Cams.
490
491 - callisto: removed unsused intensity calibration from MJCalibration
492 for further simplification
493
494 - callisto: for simplification removed references to
495 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
496 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
497 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
498 (this should at minimum change nothing at all, and at maximum
499 improve thing if these containers where somewhere not handled
500 properly)
501
502 - callisto: Added the option to write an event movie. Please use
503 this option with care (huge files) but exessively to understand
504 our events. For further documentation please refer to the
505 IACT wiki
506 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
507
508 - callisto: Improved binning for the pulse position check histogram
509
510 - callisto: The code calculating the pulse position checknow takes
511 the pedestal into account
512
513 - callisto: The arrival time is now stored with full precision this
514 helps to get rid of artefacts in histograms. For the signal this
515 is not necessray because it is displayed in log-scale anyhow
516
517 - callisto: Fixed a problem with internal exclusions. Pixels which
518 have once been marked as unsuitable didn't get the necessary
519 histograms filled anymore to be rechecked with each interleaved
520 calibration.
521
522 - callisto: The relative arrival time resolution (the rms of the
523 relative arrival time offset) is now checked against its
524 median and the median deviation, instead of the average
525 plus an absolute offset.
526
527 - callisto: The relative arrival time offset is now calculated
528 w.r.t. its median not w.r.t. to an artificial reference pixel.
529
530 - callisto: The relative time calibration now marks pixels with
531 outlaying offset as unsuitable
532
533 - callisto: The interleaved relative time calibration has been switched
534 on. The advantage is that pixels which are marked as outliers
535 now can recover. An improvement over time is not expected, because
536 the relative time calibration seems stable.
537
538 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
539 option can now be omitted.
540
541 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
542 or the option "-mc" is specified as default the monte carlo datacenter
543 paths (/magic/montecarlo/...) are used if not overwritten in the
544 dataset file.
545
546 - ganymed: The output files now contain run- and event-number for all
547 events, accessible as RunNumber.fVal and EvtNumber.fVal
548
549 - ganymed: Added a plot showing the source position in the camera also
550 for wobble mode
551
552 - ganymed: In addition to the existing task which can be setup to
553 be executed after Cut1 a final task called "EstimateEnergy"
554 has been added, executed before writing the final output
555 (ganymed00000000.root). The task setup in all three cases
556 can be choosen individually. (For all three(!) cases you
557 can for example choose MRanForestCalc. For examples see all
558 sponde*.rc and all ganymed*rc)
559
560 - ganymed: If a container "MEstimatedEnergy" is found in the
561 parameter list (eg. because it was setup by MEstimateEnergy)
562 it will be written to the output file.
563
564
565
566 *** Version 1.0 (2007/02/16)
567
568 - database: Website to plot values from the database has been added.
569
570 - database: The rate of spark events as found by star is now kept
571 and the rate after cleaning is now with spark events subtracted
572
573 - general: The changes to the interpretation of phrases lead to
574 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
575
576 - general: Added example files how you can create your own calendar
577 (eg. as christmas present) with Mars. Just run
578 root macros/tutorials/calendar.C
579
580 - general: Added a possibility to display grouped data in the plotdb.C
581 macro (and similar macros). This allows to plot hourly, nightly,
582 weekly, monthly and yearly averages.
583 For more details see the plotall function of the macro
584
585 - general: fixed the error display of the camera display. It showed
586 wrong results.
587
588 - general: fixed a memory leak when reading many MStatusDisplays
589
590 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
591 between a spherical and a parabolic mirror
592
593 - callisto: We have a new pulse position check which takes the properties
594 of the extractor automatically into account. So no need to set
595 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
596 left is done. If possible the lo-gain extraction start and hi-gain
597 extraction end is changed accordingly. If no proper extraction range
598 can be set (hi-gain too much to the left) an error is raised.
599
600 - callisto: New swapped pixels have been found and corrected
601
602 - callisto: Redone the signal extraction this includes:
603 + Unified the algorithms to extract the pedestal for all pedestal
604 extractions done
605 + Unification of hi- and lo-gain into one array
606 + Unification of hi- and lo-gain extraction for Spline and
607 Digital Filter (means now exactly the same algorithm is used,
608 not a copy-and-pasted one)
609 + Store pedestal subtracted data in a common place
610 + Improved extraction algorithms. If the algorithms search a
611 maximum but don't find one they don't return the maximum anymore
612 + Improved the extraction such that a information for signal
613 and time which is consistent is returned
614 + replaced the numerical spline with a (not slower) analytical
615 solution
616 + Lowered the saturation limit from 250 to 245 to make sure that
617 we are far away in all pixels from problems with the clock-noise
618 + The start of the lo-gain extraction is calculated from the hi-gain
619 arrival time. In case of saturation an estimation is used.
620 + the hi-gain window was extended to slice 16. This allows extraction
621 of very late pulses in single pixels or of huge hadron showers.
622 + Now uses the lo-gain extraction range for pedestal extraction,
623 not the hi-gain range in the lo-gain
624
625 - callisto: New hi-/lo-gain calibration constants have been produced
626 for all periods from the statistic of the whole period. They are
627 now used automatically depending on the periods. The old constants
628 where deviation in avarega about 2%-3%. The constants are very
629 stable from period to period (<<1%) except for exchanged channels.
630 In a few cases the constants used so far were off by 1%-2% (maybe
631 temperature effects?)
632
633 - callisto: To gain obsolete space we do not write the
634 MPedestalFundamental anymore. Also calibration and bad pixel
635 treatment is not done for it anymore because it has never been used.
636
637 - callisto: Fixed a bug in the seuqence handling which caused the
638 light condition to be ignored
639
640 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
641 basically the same as "Cleaned" but the distribution devided into
642 the events fullfilling a spark cut or being rejected by it.
643 This cut can be changed from star.rc (see example inside) by
644 the "SparkCut" directive
645
646 - star: Star displays now the average individual pixel-rate (IPR) versus
647 time and the average discriminator threshold (DT) of all pixels.
648
649 - optim: fixed a problem with the optim-macros which was due to a bug
650 in the new phrase parsing
651
652 - ganymed: To get a nice FalseSource plot (instead of the all-information
653 debug plot displayed as a standard plot) use the context menu
654 somewhere between the two upper plots, click on "DrawNicePlot"
655 and enjoy the result. (It is the same context menu which contains
656 the other options)
657 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
658
659 - ganymed/optim/train: The cut program, trainings- and optimization
660 macros could run with less files found than expected from the
661 sequence-files. No the execution is stopped in this case.
662
663 - ganymed: now stores the dataset in the output file with all information
664 contained (as sequence number, sequence path, data path) so that the
665 used dataset file can be recreated complete from the output
666
667 - sponde: now also allows the uasge of random forest
668
669 - sponde: added a plot showing the cut efficiency
670
671 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
672 errors (eg. effecting the collection area) because the errors of the
673 two histograms were swapped in the calculation, which makes a difference
674 in the case the histograms contains weighted events. Aditionally the
675 totalarea was incorrectly taken into account, which results in too small
676 errors, which makes a difference at low statistics were the errors
677 or the collection area dominate.
678
679
680
681 *** Version 0.10.3 (2006/10/23)
682
683 - database: Implemented ObservationMode flag in websites.
684
685 - database: For sequences there is now also the stoptime available on the
686 websites.
687
688 - database: Removed ManuallyChanged flag from sequence-info websites,
689 as it is not needed anymore with the new sequence building algorithm.
690
691 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
692 Class for calculation of confidence intervals (upper limits).
693 Use model 3 or 4 for upper limit calculation for MAGIC observations.
694 Please read the class instruction of TRolke for more information.
695
696 - general: The programs now return 0xfe if the requested resource file
697 doesn't exist.
698
699 - general: Errors comming from root itself are now not output to
700 stderr anymore but to our default (colored) log-stream.
701
702 - general: Changed the interface to TFormula such that now everything
703 is parsed by TFormula, which should allow to use phrases even
704 without paranthesis correctly parsed.
705
706 - callisto: replaced the AdHoc number of effective integration slices
707 in the digital filter by an average of the correct number, averaged
708 over all possible set of weights. This also gives correct numbers
709 for the lo-gains which were totally wrong before.
710
711 - callisto: drastically reduced memory consumption by not storing
712 all intermediate calibration results in memory anymore (we might
713 write them into a file in the future)
714
715 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
716 debug plot displayed as a standard plot) use the context menu
717 somewhere between the two upper plots, click on "DrawNicePlot"
718 and enjoy the result. (It is the same context menu which contains
719 the "DrawAll" option)
720 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
721
722
723
724 *** Version 0.10.2 (2006/10/15)
725
726 - general: changed the building of the sequence files such, that
727 the source-/project name in case of wobble-sources is not the
728 source/project of the first data run anymore but the new generalized
729 wobble source/project
730
731 - general: Added some functions to MAstro to calculate sun and
732 moon properties
733
734 - general: Added two new macros (starvisday.C and starvisyear.C)
735 which allow to plot the visibility of several stars in one day
736 or of one star along one year
737
738
739
740 *** Version 0.10.1 (2006/10/11)
741
742 - general: HTML logging output was distorted... fixed.
743
744 - general: Changed the writing of the sequencefiles such that only
745 as many pedestal files as giving at least 1000 pedestal events which
746 are nearby the first calibration run are used as pedestal runs
747
748 - sponde: In the calculation of the collection area(s) and the
749 distribution for MOnte Carlo and estimated energy the error
750 calculation was wrong because root didn't take the errors
751 properly into account... fixed.
752
753
754
755 *** Version 0.10 (2006/10/10)
756
757 - general: all executables now check consistency of the root version
758 installed with the root version used for compilation. The return
759 code in this case is 255.
760
761 - general: The algorithm to build seqeunces has been redesigned
762 completly. It is now more flexible in terms of a resource file
763 resources/sequences.rc which can be used to partly overwrite
764 the default algorithm and defined the important part of the
765 algorithm. It also takes correctly into account several ways
766 of taking wobble-data. Currently the new algorithm doesn't take
767 the number of pedestal events anymore into account (so a sequence
768 could have much less than 1000 pedestal events and data runs are
769 no-more used instead)
770
771 - general: a lot of small changes to make the code compatible with
772 root 5.12/00 and gcc 4.1
773
774 - general: Fixed some warnings thrown if more warnings are switched
775 on in the compiler
776
777 - general: Added a function to MMath which returns the Median of
778 the distribution abs(y[i]-median) but at 68:32 division instead
779 of 50:50, which is somehow the median counterpart of the rms.
780
781 - general: MAstroCatalog allows now to read calatog files (as bsc5)
782 even if they are compressed with gzip (recommended compression
783 is with "-1")
784
785 - showplot:
786 + batch mode creation of image files now works with root 5.12/00
787 + added support for writing bmp (though it never produces
788 bmp which can be read by programs like xv or gimp)
789 + added support for xml
790 + added new option to start the display with a different size, by
791 --display-width=nnn or --display-height=nnn
792 + added options to define the canvas size when the display is started
793 --canvas-width=nnn or --canvas-height=nnn
794 the option can also be used for batch-mode conversion
795 + added an option which automatically fits the display size to the
796 desktop-size: --auto-size
797
798 - merpp: didn't recognize files with the extension .raw.gz - fixed.
799
800 - merpp: allow the reports to have 1000ms due to a bug in the camera
801 program.
802
803 - callisto: New swapped pixels have been found and corrected. For
804 details see MRawRunHeader::FixAssignment()
805
806 - callisto: Callisto now raises an error if one of the input files could
807 not be opened.
808
809 - callisto: In some rare cases it could happen that in the signal
810 extraction of the digital filter the extractor returned nonsense
811 results due a wrong initializion of a variable (this happens in
812 cases in which the extracted signal is exactly zero or the
813 digital filter couldn't slide because of a too small extraction
814 window, which could happen in the lo-gain extraction)
815
816 - callisto: The lo-gains have been marked as valid in some cases
817 when they got not extracted at all (deltsumlo=deltatimelo=0) because
818 the allowed extraction range (fLoGainLast-fLoGainFirst) was
819 smaller than the number of slices (fLoGainWindowSize) needed
820 by the lo-gain extractor
821
822 - callisto: Updated absolute calibration constants (muon calibration)
823
824 - callisto: fixed a bug which caused the hi-gain saturation not
825 to be handled properly in the spline (the position of the
826 saturation was calculated incorrectly)
827
828 - callisto: fixed a bug which gave weird results if hi- _and_
829 lo-gain could not be extracted properly. In some cases hi-
830 and lo-gain have not been extracted at all and the random result
831 got calibrated. In other cases the hi-gain was saturating and the
832 lo-gain has not been extracted. For this a completly arbitraty
833 scale factor was applied to the result from extracting the
834 charge of the saturating hi-gain.
835
836 - callisto: improves handling of extracted signal if lo- and/or
837 hi-gain could not be extracted properly. If no appropriate
838 calibration of either the signal or the arrival time is possible
839 the pixel is now markes as unsuitable instead of estimated.
840
841 - callisto: Fixed a problem in the spline extraction which gave
842 weird results if the signal was extracted from the first (and
843 highest) slice (as a workaround extraction from the first
844 slice has been forbidden)
845
846 - callisto: Fixed a bug regarding the use of the QE which doesn't
847 effect the result because the default is used anyhow.
848 (The bug was there since 14/07/2005)
849
850 - callisto: Changed the default for fgLoGainStartShift to -2.4
851
852 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
853 factors to be always 10 for all pixels as soon as the first
854 calibration update has happend.
855
856 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
857 was off by more than one slice (which gives wrong values for
858 pixels which have saturated the hi-gain) This was a problem
859 mainly for timing studies, not so much for the automatic standard
860 analysis. Also the values for the Spline have been changed slightly:
861 + Digital Filter from 1.70 to 0.95
862 + Spline from 1.39 to 1.30
863 The numbers were sorted out by an extensive test in the
864 test-database.
865
866 - callisto: Removed the tab showing the average calibrated arrival
867 time. It never gave useful information.
868
869 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
870 lo-gain pulse for data pulses if hi- and lo-gain have saturated
871 and both were extracted because the hi-gain was above the
872 LoGainSwitch.
873
874 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
875 lo-gain pulse position (after application of LoGainOffset, which
876 means in the ideal case it is 0) for data pulses if hi- and lo-gain
877 have saturated and both were extracted because the hi-gain was above
878 the LoGainSwitch.
879
880 - callisto: After extensive tests a new threshold level for determination
881 of the pulse position has been found at 50phe. This is due to the
882 fact that for lower pulses the arrival time changes its average
883 behaviour dramatically. It tends to the average of the extraction
884 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
885
886 - callisto: Added two more plots to the calibration part. The average
887 extracted signal and the average extracted arrival time as
888 extracted by the signal extractor (This can help debugging problems
889 because it doesn't involve a fit)
890
891 - star: changed the fit for the effective on time such that initial
892 values are calculated automatically now instead of using build
893 in values. This makes the fit more indepedant of the underlaying
894 rates. With a test of ~350 sequences in the test database it could
895 be shown that the new fit gives the same result +/-1sek.
896 The highest deviation was +5s the lowest -10s. You can now control
897 the bahaviour with two resource values:
898 MHEffectiveOnTime.FistBin: 3
899 MHEffectiveOnTime.NumEvents: 12000
900 Use FirstBin=1 and NumEvents=120 to fit the effective on time
901 from the resulting gamma candidates
902
903 - star: The Center histogram in MHHillas is now by default displayed
904 with the colz draw-option
905
906 - ganymed: now produces valid error codes if failed
907
908 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
909 with the option "hadronness" instead of "area" or "both" if
910 you want to use both cuts. The hadronness cut includes a fixed
911 cut in hadronness (index 8) and a fixed cut in size (index 9).
912
913 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
914 the M3Long of the anti source to be not properly evaluated
915 (actually is was evaluated as a unique random number) in case
916 of optimization with anti-theta cut switched on. This might have
917 lead to improper, but not necessarily wrong, optimization results.
918
919 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
920 how to use random forest
921
922 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
923 ganymed_onoff.rc. Seems to be unintentional that they were different.
924
925 - sponde: Since the introduction of the possibility to define a
926 normalization energy instead of using the integral the default
927 was not using the integral anymore but a normalization energy of
928 1GeV. It is now the integral again.
929
930 - sponde: Fixed a problem in the weighting which did not allow
931 a MC slope of -1.
932
933
934
935 *** Version 0.9.6 (2006/05/24)
936
937 - general: changed the binning of the azimuthal profile of the camera
938 such that it is aligned with the 60deg boundaries.
939
940 - merpp: better handling of problems with the TH, TD part of the
941 CC-REPORT for files older than 200507190 and 200412210
942 respectively
943
944 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
945
946 - merpp: implementd latest changes in starguider reports (sinc 9th May)
947
948 - callisto: if an arrival time is extracted outside the fadc range is
949 was set to the boundary before. Now a random number is assigned
950 instead to avoid unfortunate coincidences of arrival times just
951 by this arbitrary value.
952
953 - callisto: added a new option to callisto.rc which allows
954 to set the maximum arrival time difference allowed for the
955 badpixel algorithm to determin whether a pixels belongs to a shower:
956 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
957
958 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
959 to 0.9 as suggested by Stefan due to a recent study on the fraction
960 of pixels surviving the image cleaning
961
962 - callisto: switched off error in case of "pulse is too much to the left"
963
964 - callisto: The extraction window is not adapted anymore. This means that
965 the pulse is extracted from the full range. The draw-back is that the
966 background (pedestal) will become slightly higher. Switching on/off
967 the PulsePosCheck in the callisto.rc only effects filling the
968 histograms.
969 WARNING: If the pulse is too much to the left data is calibrated!
970 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
971 in the database to make sure that your data is valid!
972
973 - star: Show also the number of stars correlated correctly by the
974 starguider
975
976 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
977 than one off-source region in wobble-mode. To use it add the following to
978 your ganymed_wobble.rc:
979 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
980 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
981 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
982 + Cut1.ThetaCut: None
983 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
984
985 - ganymed: in the case the latest report is older than a default (currently
986 one minute) and the current report will be skip the starguider
987 correction and calibration will be reset. The maximum age can be
988 setup from ganymed.rc by (minutes):
989 MPointingDevCalc.MaxAge: 1.5
990
991 - ganymed: A first implementation showing all size-bins for the theta-sq
992 resp. alpha-plots in a single tab automatically
993
994
995
996 *** Version 0.9.5.1 (2006/05/05)
997
998 - general: Added a new option "zdiff" to the Makefile which runs
999 "cvs diff" as "make diff" would do, but with compression
1000
1001 - general: accelerated MTFillMatrix (used for eample in all training
1002 and optimization macros) by skipping some obsolete calles in the
1003 eventloop the first and second loop could be accelerated by ~20%
1004
1005 - general: Added a missing feature in the MFilterList class which
1006 prevented MFEnergySlope from working correctly in trainenergy.C
1007
1008 - general: Accelerated the random forest training and usage a bit
1009
1010 - merpp: Adapted to new raw data file format version 6
1011
1012 - merpp: fixed a problem with reading the starguider reports
1013 after 6.3.2006
1014
1015 - callisto: At some times six pixels had to be exchanged manually in the
1016 data. If the pixels to be swaped are both not found, an error was raised
1017 and calibration was stopped. Now it is assumed they are intentially not
1018 mapped and the Error has been changed to a Warning.
1019
1020 - star: Added new image cleaning based on the arrival time of the shower.
1021 The new cleaning can be accessed using the parameter "Time" instead of
1022 the the old one (like "Absolute) in the star.rc-file.
1023 Recommended parameters:
1024 + MImgCleanStd.CleanLevel1: 8.2
1025 + MImgCleanStd.CleanLevel2: 5
1026 + MImgCleanStd.CleanRings: 2
1027 + MImgCleanStd.KeepSinglePixels: No
1028
1029 - star: Simplified the calculation of the effective on time. By letting
1030 the fit start in the third bin the result should become more stable.
1031 The fit quality is now ignored for the theta-plot which is not used
1032 in the analysis later. Still better pre-cut which, for example,
1033 remove events triggered by car-light (rate changing on a short
1034 time-scale) are missing.
1035
1036 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1037 for optimization (kWeakSource) which is suggested by the Berlin
1038 people for weak sources.
1039
1040 - macros: plotdb.C:
1041 + if no dataset and no time-interval is given only sequences with
1042 an effective on-time above five minutes are plotted anymore
1043 + added a new tab "RelTime" displaying the relative on-time
1044 (effective on-time divided by the observation time)
1045
1046 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1047 the optimization became a lot faster
1048
1049 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1050 To display them just delete the pads displayed on top.
1051
1052 - ganymed: fixed a bug which could cause strange behaviour in wobble
1053 mode if no starguider information was available due to an incorrect
1054 initialization of the starguider calibration
1055
1056 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1057 be changed from within the plot. It can also be setup from the
1058 resource file using:
1059 + MHDisp.fScaleMin: 0.325
1060 + MHDisp.fScaleMax: 0.475
1061
1062 - ganymed, showplot: Fixed a problem with the fit to the off-data
1063 (HistOff) which could cause a time lag or an inifinite loop.
1064 The bug did not effect the results at all.
1065
1066 - sponde: Added a new tab showing the effective collection area after
1067 trigger (including the software trigger)
1068
1069 - sponde: MMcSpectrumWeight has a new option which allows to define
1070 the scaling factor not by the integral of the events but at
1071 a defined energy:
1072 e.g. MMcSpectrumWeight.NormEnergy: 200
1073
1074 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1075 eventloops the loop could be accelerated by ~20%
1076
1077
1078
1079 *** Version 0.9.5 (2006/03/13)
1080
1081 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1082 and added the standard Disp-parametrization
1083
1084 - macros: added a new macro datacenter/macros/plotstat.C allowing
1085 to plot statistics about the data processing
1086
1087 - macros: added a new macro to plot the muon correction coefficients
1088 versus period (macros/plot/mucal.C)
1089
1090 - showplot: path inflation for ganymed files was broken
1091
1092 - callisto: Fixed an important bug. When the number of saturating pixels
1093 were calculated the bad pixel information already available from the
1094 calibration was ignored. This yields wrong values in case pixels
1095 are broken and saturate all the time or randomly.
1096
1097 - callisto: Updated Muon calibration constants. Spline data now also uses
1098 different values for different periods
1099
1100 - star: The time-evolution shown in the effective on-time plot now displays
1101 the axis range (if there are no holes it should be similar to the
1102 effective on-time)
1103
1104 - star: Added two new image parameters:
1105 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1106 the three pixels next to the center of gravity and the size
1107 + MNewImagePar.fConcCore: The ratio of the signals of all
1108 pixels inside or touching the ellipse and the size
1109
1110 - ganymed: now stops in requested source isn't found in catalog file
1111
1112 - ganymed: Many improvements to the phi-plot in wobble mode:
1113 + with a template the ideal background is displayed
1114 + a possible camera inhomogeneity is taken into account
1115 + the anti theta cut is better supported
1116 + the phi cut is automatically calculated from the theta cut
1117 See the examples in ganymed_wobble.rc for more details.
1118
1119 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1120 times the bin-width instead of the absolute energy
1121
1122 - ganymed: New cuts for on/off and wobble mode
1123
1124 - ganymed: The smearing of the False Source plot has been increased
1125 to 0.06
1126
1127 - ganymed: The starguider calibration can now be changed from the
1128 resource file.
1129 See the examples in ganymed*.rc for more details.
1130
1131 - ganymed: added a new option for on-/off-observations
1132 MJCut.RandomSourcePosition
1133 If switched on the distribution of observation time of the source
1134 position in the camera is calculated from the on-data and randomly
1135 applied with this distrbution to the off-data.
1136
1137 - ganymed: by skipping some obsolete calles in the eventloop the
1138 first and second loop could be accelerated by ~20%
1139
1140 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1141 position in the off-data randomly according to its distribution in the
1142 on-data.
1143
1144
1145
1146 *** Version 0.9.4.3 (2006/02/13)
1147
1148 - general: Fixed a bug in most of the programs which prevented the
1149 compile date in the startup message to be displayed
1150
1151 - general: Simplified program calls. The following abbreviations
1152 are now possible:
1153 showlog callisto 55599
1154 showplot signal 55599
1155 star 55599
1156 callisto 55999
1157 ganymed 2
1158 In this cases the corrsponding root-, log-, sequence- or dataset-
1159 filename is automatically compiled using the default datacenter
1160 paths ("/magic/*")
1161
1162 - general: Fixed a long outstanding bug which made axis tick marks
1163 disappear if MDataFormula was used (eg. abs(x))
1164
1165 - general: Updated MMath with new functions to calculate the results of
1166 a exponential, logarithmic and powerlaw fits analytically.
1167
1168 - general: Updated some macros with comments:
1169 + macros/optim/optimdisp.C
1170 + macros/optim/optimenergy.C
1171 + macros/optim/optimwobble.C:
1172
1173 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1174 files) now allows adding a pre-cut like in the optimization. E.g. this
1175 is useful to perform g/h-separation cuts before training the random
1176 forest.
1177
1178 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1179 correctly assigned in the raw data assignement table. A fix to correct
1180 the assignment tabel have been implemented.
1181
1182 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1183 by 90, 180 and 270 deg.
1184
1185 - general: the macro plotdb.C now allows to highlight sequences belonging
1186 to a datset. For more details see the descritions in the macro.
1187
1188 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1189 of the display, it gave wrong results espacially for big sizes.
1190 Now the embedded canvas should always have a ratio width/height=3/2.
1191 The "Size" options have been updated with values fitting the 3/2
1192 size ratio.
1193
1194 - RanForest:
1195 + Updated the random forest classes to support also the
1196 regression method implemented by Thomas H.
1197 + added new tutorial macro how to train the random forest
1198 for energy estimation (macros/optim/rfenergyest.C)
1199 + new classes to train the random forest (still in development)
1200 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1201 + new tutorial macros for random forest training in macros/train
1202 trainenergy.C, traindisp.C, trainseparation.C
1203
1204 - mars: now allows to setup a cut in the resource file mars.rc to choose
1205 the events to be displayed, eg:
1206 Cut.Condition: {0} && {1}
1207 Cut.0: MHillas.fSize>100
1208 Cut.1: MHillas.fSize<900
1209
1210 - merpp: Made aware of the new .rep format 200510250. This includes
1211 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1212 the discriminator thresholds (MCameraTD) and the disciminator
1213 delays (MCameraTD). All of them come with the CC report and are therefor
1214 written to the CC tree.
1215
1216 - callisto: fixed a bug in the calculation of the arrival times in
1217 the Digital Filter. They were all shifted by the same amount
1218 fHiGainFirst. This caused an offset in the order of the position of
1219 the left border of the extraction window in the times calculated
1220 from high-gain and from low-gain. The bug effected only the absolute
1221 arrival times. The bug was there since 30.1.2005.
1222
1223 - callisto: Changed the ExtractionWindow for the pulse position check
1224 such that the camera inhomogeneity becomes as less as possible and
1225 comparable to the pulso position check switched off. More details
1226 on the study will be given at our result web-page.
1227
1228 - ganymed: ganymed.rc, ganymed_onoff.rc:
1229 changed to new cuts trained with 1ES1218 and Crab-data
1230 for maximum sigma*log10(excess)
1231
1232 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1233 a new option was implemented to estimate Disp (CalcDisp)
1234
1235 - ganymed: Implemented two new options which allow
1236 to overwrite the default path to search for the sequence files
1237 --ins=/magic/sequences
1238 and where to search for the image data
1239 --ind=/magic/data/star
1240
1241 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1242 dx/dy from the resource file by
1243 MSrcPosCorrect.Dx
1244 MSrcPosCorrect.Dy
1245
1246 - ganymed: fixed reading the source catalog. Only as many chars
1247 as the requested source name had were compared (If a source
1248 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1249 were requested it could happen that the coordinates of
1250 "1ES1218" were read) The source coordinates are now printed
1251 in addition to its name to the logging output.
1252
1253 - ganymed: changed the background fit in the case of a ThetaSq function
1254 from a polynomial to a exponential, this should give a big improvement
1255 for on-only analysis'
1256
1257 - ganymed/sponde: Calculation of the error of single size-/energy-
1258 bins now uses Li/Ma (5) instead of LiMa (17)
1259
1260 - sponde: Added a plot E^2*dN/dE
1261
1262 - sponde: The energy estimator plot should now show values like
1263 they are commonly used.
1264
1265 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1266 (a powerlaw with cutoff didn't work before)
1267
1268
1269
1270 *** Version 0.9.4.2 (2005/10/01)
1271
1272 - general: added new tutorial macro macros/tutorials/threshold.C:
1273 how to calculate the threshold
1274
1275 - general: added a new game. Start it from the interpreter with
1276 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1277 and MagicReversi)
1278
1279 - general: neighbor pixels in MGeoms are now sorted clockwise
1280
1281 - merpp: made aware of new format 20050829-0
1282
1283 - callisto: New scale factors from muon analysis, stored in new
1284 resource file resources/calibration.rc
1285
1286 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1287 the eventloop if something went wrong. This is necessary for the
1288 automatic processing
1289
1290 - callisto: Implemented a new treatment for the time information
1291 developed by S.Ruegamer, this should give much better response than
1292 the old very primitive algorithm. This is especially important
1293 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1294 treatment was buggy! As neighbor pixels to interpolate the
1295 arrival times always the pixels 0 to 5 were taken)
1296
1297 - callisto: In addition to the new treatment of arrival times the
1298 decision of the treatment whether a pixel contains shower
1299 information or not is used to improve the signal interpolation
1300 further. Previously interpolated pixels showed a non-zero signal
1301 do the peak searching signal extractors. Having a signal pixel
1302 beside raised the signal above the cleaning level. Thus the
1303 pixel survived cleaning to often but with a too low mean signal.
1304 By replacing empty pixels with a gaus (mean and rms from the
1305 corresponding Area entries in MPedPhotCam) this effect can
1306 be supressed.
1307
1308 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1309 got lost when the events were stored by the calibration... fixed.
1310 (This was no problem for normal image cleaning because the pixel
1311 content was artificially set to 0 not surviving standard cleaning
1312 algorithm)
1313
1314 - callisto: Fixed a bug which caused the random and peak-search pedestal
1315 extracted with an extractor to be exchanged for the first (roughly)
1316 500 events (*Extractor and *ExtractorRndm).
1317 (They were simply exchanged in callisto.cc) This bug might have been
1318 introduced in Mars 0.9.4 when the order of calculation of the two
1319 types of pedestal in callisto got exchanged. The bug only effects
1320 the first seconds of data of each sequence.
1321
1322 - star: Taking the arrival time of Muons into account the calculation
1323 of the parameters could be made independant of the noise
1324 (pedestal rms). The dependance was due to the bias of the peak search
1325 extractor. Now only a ZA dependamcy is left which is not yet fully
1326 understood.
1327
1328 - ganymed: The sequences were still not sorted correctly in any case,
1329 because they were sorted by the full qualified path name. Now they
1330 are sorted by their sequence number.
1331
1332 - ganymed: new values for the spark-event-cut
1333
1334 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1335
1336
1337
1338 *** Version 0.9.4.1 (2005/08/18)
1339
1340 - callisto: fixed some problems with the calibration in case of
1341 inteleaved events. Therefor the final and some intermediate
1342 fits are skipped which would take place on partly filled #
1343 histograms and gave wrong results or failed completely.
1344
1345 - callisto: If the intermediate finalization of the histograms
1346 calculating the mean charge of the calibration signal fails
1347 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1348
1349 - ganymed: Fixed some bugs which caused problems in On-only mode.
1350 Still the false source plot doesn't give reasonable results.
1351
1352
1353
1354 *** Version 0.9.4 (2005/08/05)
1355
1356 - general: Fixed the ZA binning. It did not correctly fit the
1357 MC binning
1358
1359 - general: Added a class to correct for the missfocussing in
1360 April (MSrcPosCorrect)
1361
1362 - general: Random Forest energy estimator should now work properly
1363
1364 - general: MHCamera now displays the profiles in deg instead of mm
1365
1366 - general: MH::SetPalette offers a lot of new palettes
1367
1368 - general: MHillas - the case of CorrXY==0 is now handled properly
1369
1370 - general: implemented the possibility to change the line and
1371 marker style of a sky-grid drawn by MAstroCatalog
1372
1373 - general: Runs in sequences and datasets are now automatically
1374 ordered (it is assumed that the order of their filenames correctly
1375 represents the order of observations) to ensure correct reading
1376 of the subsystem data
1377
1378 - general: Runs cannot be added to a sequence twice anymore. Also
1379 Sequences cannot be added twice anymore to a dataset.
1380
1381 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1382 It gave wrong results by 1./2pi
1383
1384 - showplot: got a new option to start a root interpreter, too
1385
1386 - mars: now displays a rough estimate of Disp and the third moment
1387
1388 - mars: now displays the event time MTime if available
1389
1390 - mars: show muon parameters graphically
1391
1392 - mars: now the file to open can be given as commandline
1393 argument
1394
1395 - merpp: Added support for new arehucas version >= 200507190
1396 implementing values for three temperature sensors in the
1397 counting house (MCameraAUX) and the name of the HV settings file
1398 (MCameraHV).
1399
1400 - merrp: Also fixed some problems with wrong versions numbers stated
1401 by arehucas and implemented some fixed for old versions (<200407070)
1402
1403 - callisto: MCalibrationHiLoCam can now be printed from its context
1404 menu, eg in the TBrowser
1405
1406 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1407 - 1.39 (MExtractTimeAndChargeSpline)
1408 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1409 This is important mainly for timing studies.
1410
1411 - callisto: Changed limits in MHCalibrationChargeCalc from
1412 - -100.125 to -98 (fgChargeHiGainFirst)
1413 - 1899.875 to 1902. (fgChargeHiGainLast)
1414 - -100.25 to -99 (fgChargeLoGainFirst)
1415 - 899.75 to 901. (fgChargeLoGainLast)
1416 Introduced new limits:
1417 - fgNumLoGainBlackoutLimit: 0.05
1418 - fgLoGainBlackoutLimit: 3.5
1419 - fgLoGainPickupLimit: 3.5
1420
1421 - callisto: The handling of automatic weights for the digital filter
1422 has been improved. There are now new calibration weights special
1423 for Monte Carlo calibrations.
1424
1425 - callisto: Updated Muon scale with latest results (1% difference
1426 for most data, 5% for Mar/Apr'05)
1427
1428 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1429 was saturated and the blackout-events in the low-gain exceed the
1430 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1431 This excludes those pixels which have a saturating high-gain
1432 channel, but the low-gain switch does not switch often enough
1433 to make the distribution reliable.
1434
1435 - callisto: fix a bug counting the number of saturated events. Up to now,
1436 the number of saturated slices was counted (which is one for a not too
1437 high number), but for some (pathological) pixels, many more slices
1438 saturated and produced wrong limits.
1439
1440 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1441 + MCalibrationRelTimeCam.CheckFitResults: Yes
1442 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1443 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1444 + MCalibrationRelTimeCam.CheckOscillations: Yes
1445
1446 - callisto: introduce max. number of events for intercalibration,
1447 the rest gets skipped. Default: 4096
1448 The calibration causes too many un-reliable pixels if more
1449 than about 5000 events are treated (@500 Hz) because of the
1450 mode hopping of the VCSels. However, in the past, some
1451 calibration runs have been taken (erroneously) with more
1452 than 5000 events, especially the intensity scans where
1453 a good precision is needed.
1454
1455 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1456 photo-electrons for the spline extractor by 1-2% (correctly).
1457
1458 - callisto: The intercalibration is now done using a full f-factor
1459 method instead of a simple update. This makes things slower but
1460 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1461 changes.
1462
1463 - callisto: MPedestalY3 now uses the same extraction range as the data
1464 as calculated by MPedestalY2
1465
1466 - callisto: A check of the fraction of allowed unsuitable (10%) and
1467 unreliable (30%) pixels has been addded when the conversion is
1468 calculated from interleaved events
1469
1470 - star: fixed a bug which caused MEffectiveOnTime containers not to
1471 be written. In the worst case they were skipped almost all, in the
1472 best case they were all ok. It depends on how often the new value
1473 was assigned just with an event which was skipped later by another
1474 task
1475
1476 - star: new histograms MHPointing and MHRate
1477
1478 - star: New tab (Currents) displaying the time evolution of the mean
1479 DC currents
1480
1481 - star: New tab (MeanRms) displaying the time volution of the mean
1482 Pedestal Rms
1483
1484 - star: Output now contains MReportStarguider
1485
1486 - star: Improved muon analysis. Due to the absense of a constant
1487 for the gaus fit for arc width and the fact that the arcwidth
1488 plot was a histogram instead of a profile the resulting psf
1489 became pedestal rms dependant
1490
1491 - ganymed: added new plot (MHPhi) for wobble mode as described in
1492 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1493
1494 - ganymed: corrects now (correctly?) for the misspointing in
1495 May/April 05
1496
1497 - ganymed: Two new default templates for ganymed.rc are avilable:
1498 ganymed_onoff.rc and ganymed_wobble.rc
1499
1500 - ganymed: The first version of MFMagicCuts has been released
1501
1502 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1503
1504 - ganymed, sponde: There are two new options to determin the number
1505 of bins for the signal region (NumBinsSignal) and the number of
1506 total bins (NumBinsTotal) in the MHThetaSq histogram
1507
1508 - ganymed: optimized palettes for MHDisp
1509
1510 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1511 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1512 sqrt(2) to large
1513
1514 - ganymed: The false source plot (MHDisp) is now based on Disp
1515 and a background model determined in the first loop is
1516 subtracted
1517
1518 - ganymed: MFMagicCuts are now available in the cvs. The correct
1519 solution for the disp ambiguity problem is now calculated using
1520 the third moment. The third moment cut therefor is skipped.
1521
1522 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1523 already determined by the third moment along the major axis and
1524 so its actual sign is aligned along the major axis of the shower.
1525
1526 - ganymed: If starguider data is available it is taken into account
1527 when calculating the source position. This is especially important
1528 for wobble data at high zenith angles and culmination data.
1529
1530 - ganymed: If available the starguider data is taken into account as
1531 good as it is possible without a starguider calibration. To switch
1532 it off add
1533 MPointingDevCalc.MaxAbsDev: -1
1534 to your ganymed.rc
1535
1536 - sponde: the zenith angle distribution is now weighted instead of
1537 choosen by default. This gurantees higher statistics in the highest
1538 and lowest energy bins. To switch this behaviour off use...
1539
1540 - sponde: now automatically displays the energy threshold
1541
1542
1543
1544 *** Version 0.9.3 (2005/06/03)
1545
1546 - general: MMcEvt now derived from MMcEvtBasic which should
1547 have no influence on compatibility with older camera files
1548
1549 - general: Implemented a new option to MReadReports which allows
1550 to force reading of the first event of some trees (eg. Drive-tree)
1551 before any other tree.
1552
1553 - general: Made a fix to MPointingPosCalc which assumes that the
1554 run-type is real-data if Process is called before ReInit, such
1555 that also the very first Drive-events in a run are treated
1556 correctly.
1557
1558 - shoplot now displays the filename in the title bar of the window
1559
1560 - merpp: new options: --auto-time-start --auto-time-stop which
1561 allow to cut updating with slow-control at the start- or
1562 (previousle --auto-time only allowed: and) stop-time of
1563 the run stored in the runheader.
1564
1565 - callisto: changed default of fgFallTimeHiGain in
1566 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1567 already set as default in callisto_Dec04Jan05.rc
1568
1569 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1570 now changes the filename for new weights automatically for
1571 cosmics, MC and for different calibration colors.
1572
1573 - callisto: a problem with the order of some code cause the
1574 name of the weights file in MPedestalY2 to be ignored.
1575 Wrongly the calibration_UV weights were used instead
1576 of the cosmics weights set in callisto.rc.
1577
1578 - callisto: should allow ct1 pulser data when the color is
1579 explicitly set also for pretty new runs
1580
1581 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1582 to introduce an additional scale factor (should be around 1)
1583 to adapt for slight deviations in different extractors from
1584 the MC calibration. For MC calibrations the scale factor
1585 is fixed to 1
1586
1587 - callisto: MFCosmics should handle very high signals a bit
1588 more accurate now
1589
1590 - callisto: when calculating the mean pedestal rms for different
1591 pixel sizes or sectors also kUnsuitableEvt is now taken into
1592 account - not only kUnsuitableRun
1593
1594 - callisto: '-raw' option is now the default
1595
1596 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1597 This has the advantage that mean values in the calibration (eg
1598 arrival times) are calculated more accuratly.
1599
1600 - callisto: In the resource file callisto_Dec04Jan05.rc
1601 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1602
1603 - callisto: new Hi-/Lo-Gain intercalibration constants
1604 hilocalib_sp1.root and hilocalib_sp1_mc.root
1605
1606 - callisto: changed default for MJPedestalY2.MaxEvents
1607 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1608
1609 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1610 has changed from 9.0 to 6.0. This is necessary to exclude two very
1611 ringing pixels in September which - when kept - destroy the image
1612 cleaning around them (Markus G.)
1613
1614 - callisto: (!) The Muon analysis of all data taken so far has
1615 suggested that different extractors give slightly different
1616 absolute results after calibration, due to there different
1617 handling of the calibration- and cosmics pulse shape. Although
1618 the over all calibration seems to be a bit to pesimistic (or
1619 the MC seems to be a little bit - 3-5% - too much attenuated).
1620 There for correction factors have been introduced which correct
1621 the calibration constants by
1622 0.956937799 for Digital Filter (callisto.rc)
1623 and
1624 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1625 calibration. The main advantage is, that both data types can
1626 be easily analysed together and compared to the same MC sample.
1627 The factors are choosen such, that the reference is now a
1628 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1629
1630 - star: fixed a bug which caused the first bin of the histograms
1631 vs time to disapear in PostProcess. This gave wrong results
1632 on the screen. The output and all following programs not
1633 directly accessing the histograms haven't been affected
1634
1635 - star, ganymed: Made sure that always the first Drive-tree event
1636 is read and Processed before the first data event was read.
1637
1638 - ganymed: implemented the possibility to replace the standard
1639 false source plot with a different one. For example: If
1640 you want to use a Disp based FS plot use the resource:
1641 NameHistFS: MHDisp
1642 For details about the requirements of these plots look
1643 at the corresponding classes
1644
1645 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1646 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1647 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1648 case MAlphaFitter is setup correctly. For On-Only optimization
1649 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1650 RunOn() instead of Run(). For energy estimation MJOptimize
1651 has been replaced by MJOptimizeEnergy
1652
1653 - sponde: The input MC spectrum can now be weighted to fake a
1654 different spectrum. This is done via MMcSpectrumWeight. For
1655 more details see the class description and sponde.rc
1656
1657 - sponde: The paremeter comparsion plots are not scaled by
1658 their entries anymore. Instead the MC plot is scaled by using
1659 the result spectrum of the analysis. If the input MC spectrum
1660 and the result spectrum has different slopes the absolut
1661 normalization is normally wrong.
1662
1663
1664
1665 *** Version 0.9.2 (2005/05/20)
1666
1667 - general: Changed the default paths for calibrated data and image
1668 files. (The implemented access to these files doesn't yet exist)
1669
1670 - general: support for MRunIter has been removed from the job classes
1671 (use the setter functions of MSeqeunce instead)
1672
1673 - general: ProcessFile has been renamed to Process in all job classes,
1674 because ProcessFile is missleading
1675
1676 - general: The storage of the palette in MHCamera is now possible
1677
1678 - general: new bits describing unsuitable and unreliable pixels have
1679 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1680 kDeadPedestalRms, kFluctuatingArrivalTimes
1681
1682 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1683 versions newer than V200404070
1684
1685 - general: support for cc file versions newer than V200504130. Added
1686 support for active loads (MCameraActiveLoad) and central pixel
1687 (MCameraCentralPixel)
1688
1689 - general: added new histograms for image parameters versus size
1690 (MHVsSize)
1691
1692 - general: The eventloop now automatically calls PrintStatistics
1693
1694 - Status Display: Improved support for printing:
1695 + A default can now be set in .rootrc (for more details see
1696 MStatusDisplay::PrintPS)
1697 + A print dialog is opened so that printer and command line
1698 can be canged
1699
1700 - showlog: improved such that it handles different verbosity levels
1701 more accurate now. This mean you can suppress output when
1702 using showlog.
1703
1704 - showplot: improved
1705 + The new graphics formats have been implemented
1706 (pdf, svg, png, jpg and xpm)
1707 + Implemented an interface for printing. Because you can change
1708 the printing command from the command line you can use all
1709 the nice postscript tool. To print a booklet for example call:
1710 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1711 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1712 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1713
1714 - callisto: fixed a bug in the recognition of the calibration bit
1715 pattern. Concerns only intensity calibration. (The strength of the
1716 intensity has been updated in some cases)
1717
1718 - callisto: add a filter against PIN Diode events when running over
1719 calibration runs since some of the recent calibration runs have
1720 been taken with Pin Diode.
1721
1722 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1723 39943, 44833 in the calibration (MCalibColorSet)
1724
1725 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1726 been set to 1e-18 in callisto_Dec04_Jan05.rc
1727
1728 - callisto: in callisto_Dec04Jan05.rc: set value for
1729 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1730 statistics for the calculation of the mean pulse time
1731 of the cosmisc
1732
1733 - callisto: the charge limit in the calibration has been raised
1734 from 2.5 to 4.5
1735
1736 - callisto: new setup read from callisto.rc
1737 + MCalibCalcFromPast.fNumEventsDump
1738 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1739 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1740
1741 - callisto: MExtractTimeAndChargeSpline extractor:
1742 + The integration ranges were shifted by 0.2 FADC slices to the right.
1743 + unreliable handling of floating point values caused different
1744 results on different platform or with different compiler options:
1745 The new algorithm is numerically exact and more accurate because
1746 it doesn't calculate the integration position by multiple times
1747 adding the step-size (which results in numerical uncertanties
1748 exspecially if multiplied with large numbers)
1749 + A lot of fixes have been introduced which effects integrating the
1750 spline at the edges of the valid range. In this case any memory
1751 was randomly accessed. This behaviour can be tested replacing
1752 all MArrayF by TArrayF which perform a range check (but of course
1753 they are a lot slower)
1754 ! No result obtained with the Spline before can be trusted! Due to
1755 random memory access it might by completely random!
1756
1757 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1758 + extraction range in the high gain to 4.
1759 + weights file to cosmics_weights46.dat
1760
1761 - callisto:
1762 + introduce the check for fluctuating arrival times.
1763 + set charge limit to from 2.5 to 4.5
1764 + introduce asymmetric exclusion due to "deviating number of phes":
1765 Default: -9.0 +4.5
1766 + make deviating number of phes unsuitable (see David's findings).
1767
1768 - callisto: fixed the display of unsuitable pixels. The old change
1769 to a real profile in MHCamera broke it.
1770
1771 - callisto: The cosmics filter is used in MJCalibration now
1772 independant of the pulser color (formaly it was used only for
1773 CT1-pulser data). The threshold of number of max empty pixels
1774 has been raised from 2% to 5% in MJCalibration. The maximum
1775 fraction of rejected event is 50% otherwise the calibration has
1776 failed. The filter now ignores unsuitable pixels.
1777 Setup the filter from callisto.rc using "ContCosmics"
1778 (see MFCosmics::ReadEnv)
1779
1780 - callisto: changed default for fgOffsetFromLogain back
1781 from -2.8 to -1.8 in digital filter.
1782
1783 - callisto: for the common extractors
1784 + MExtractFixedWindow
1785 * MExtractTimeAndChargeSlidingWindow
1786 * MExtractTimeAndChargeSpline
1787 * MExtractTimeAndChargeDigitalFilter
1788 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1789 and fResolutionPerPheLoGain
1790
1791 - callisto: Updated the hi-/lo-gain intercalibration constants
1792 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1793 hilocalib_df6.root
1794
1795 - callisto: The default lo-gain extraction window for the
1796 MExtractTimeAndChargeSlidingWindow extractor has been increased
1797 from 6 to 8 to take the stretch of the pusle into account
1798
1799 - callisto (!!!): fixed an important bug in the setting of the
1800 incoming pedestal pointer to the signal extractor extracting
1801 pedestals. This bug caused the pedestals not to be subtracted
1802 correctly in the calibration afterwards. The effect was about 10%
1803 too high conversion factors for the digital filter and the spline
1804 and more than 40% for the sliding window.
1805 The bug existed since end of February! (Markus G.)
1806
1807 - star: added muon support to star. A new tab "MHMuonPar" is
1808 displayed. The lower right plot is an estimate of the point spread
1809 function. A reference value is displayed. To get the real PSF
1810 you must compare with MC. The setup for the muon analysis
1811 is done in star.rc. More informations can be found in
1812 MHSingleMuon and MHCalibParCalc
1813
1814 - star: The weather data is now displayed in star
1815
1816 - star: MEventRateCalc handles the calculation of the event rate more
1817 accurate now in case of the start of a new run inside a sequence
1818
1819 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1820 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1821 changed only minimally
1822
1823 - ganymed: (MJCut and MJOptimize) now displayes the number of
1824 excess events versus size. The energy estimation is done in
1825 MJSpectrum (sponde)
1826
1827 - ganymed: got support for using other variables than Alpha, eg. Theta.
1828 Therefor you need a class deriving from MHAlpha which supports
1829 this variable (one is already existing: MHTheta, which is now the
1830 default in ganymed). It is setup through ganymed.rc
1831
1832 - added a full featured spectrum program (sponde) which reads
1833 ganymed output and monte carlos and compiles a spectrum
1834
1835
1836
1837 *** Version 0.9.1 (2005/04/14)
1838
1839 - Fix bug on the arrival time reconstruction when using Digital
1840 Filter (in some marginal cases (10%) times were reconstructed shifted
1841 by 0.2 slices)
1842
1843 - all executables now return 2 where in previous versions -1 has
1844 been returned (gave problems with shell-scripts)
1845
1846 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1847 also done with a intercalibration input file
1848
1849 - a bug in the time fine adjustment of the digital filter has been fixed
1850
1851 - a lot of small fixes to calling TPad::Divide with a margin==0
1852
1853 - MStatusDisplay now shows the memory usage
1854
1855 - added a memory leak statistic after the eventloop
1856
1857 - MHadronness replaced by MParameterD
1858
1859 - MEnergyEst replaced by MParameterD
1860
1861 - wobble mode can now be switched on from the data-set
1862
1863 - switched on bad pixel detection for a pedestal level
1864 which is more than 5 times the variance
1865
1866 - Fixed default paths to be correct for the new data center
1867
1868 - Fixed handling of drive data. The pointing position in now
1869 copied to MPointingPos inside star for real and MC events
1870
1871 - made sure, that the sequences in a dataset are sorted by
1872 their number to ensure the correct synchronization
1873
1874 - added all resource files necessary to handle spline extraction
1875 of signal for the late 2004 and the early 2005 data
1876
1877 - update the reference lines for the december data
1878
1879 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1880 This is important for the Dec. and Jan. data where the calibration
1881 pulse position changes much.
1882
1883 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
1884 filter. This corrects only an defective extraction of the MC at
1885 low-gain signals lower than 90 phes.
1886
1887 - fixed some slowdown in calibrating data with interleaved events from
1888 Jan and Dec. As a workaround made the pretty palette the default.
1889 The inverse Deep Blue Sea has a bug which slows down long calibration
1890 runs a lot.
1891
1892 - implemented new values from new starguider report as defined
1893 in TDAS00-07 V7.1 (eg SkyBrighness)
1894
1895 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
1896 in starguider report (If you merpp the same reports with this version
1897 you'll get the correct units (arcmin) but a different result
1898 than with old versions (wrong units))
1899
1900 - Now the status display can also write PNG, JPEG and XPM (other file
1901 formats are still unsupported by root)
1902
1903 - added a lot of scripts and macros in directory datacenter used
1904 for automatic processing
1905
1906
1907
1908 *** Version 0.9 (2005/03/23)
1909
1910 - Calibration is now done autmatically into photo-electrons like
1911 decided by the Collaboration Board
1912
1913 - Reference lines in the display can be read from resource file
1914
1915 - Interlaced calibration events can be handled by callisto
1916
1917 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
1918 and applied in callisto.
1919
1920 - class MJCalibTest can be called by callisto
1921
1922 - callisto can now run with three data types: rawdata, rootdata, MC
1923
1924 - added two classes mreport/MReportStarguider.cc and
1925 mreport/MReportStarguider.h for implementing starguider-data
1926
1927 - the output of merpp-update now contains starguider information:
1928 MReportStarguider and MTimeStarguider
1929
1930 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
1931 values were lower than they should. This was more visible for high
1932 energy (Size) events.
1933
1934 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
1935
1936 - added a new loop to callisto to support the correct extraction of
1937 the pedestal and pedestal rms through the signal extractor
1938
1939 - added class to perform fourier tranformation of a hexagonal structure
1940 (MHexagonalFT)
1941
1942 - added class to perform fourier tranformation of a hexagonal structure
1943 in a tasklist (MHexagonalFTCalc) example: hft.C
1944
1945 - added class to enhance the MCerPhotEvt from the Magic camera geometry
1946 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
1947 small pixels, example: extendcam.C
1948
1949 - added possibility to write data to memory (TTree) using MWriteRootFile
1950
1951 - added possibility to read a TTree stored only in memory by MReadTree
1952
1953 - new classes to deal with the interleaved calibration events:
1954 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
1955
1956 - implemented filters to callisto to skip calibration events
1957
1958 - changed callisto to calculate three kinds of pedestals and pedestal rms:
1959 + fundamental pedestal (MPedPhotFundamental): extracted directly from
1960 the slices by statistics
1961 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
1962 signal extractor without randomization
1963 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
1964 with the signal extractor with randomization (extraction window is
1965 randomly fixed)
1966 The three kind of pedestal is not yet implemented (for speed reasons) as
1967 long as nobody really needs it:
1968 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
1969 extracted with the signal extractor with randomization
1970
1971 - callisto now finds the pulse position in the data automatically
1972
1973 - implemented data reduction in calibrated data by reducing the precision
1974 of the stored floating point values (pedestal, rms and signal) to
1975 roughly 0.5%
1976
1977 - fixed showplot to make file format conversion (eg. converting a
1978 status display stored in a root file into a postscript file) in
1979 batch mode possible:
1980 showplot -b --save-as-ps[=outfile.ps] infile.root
1981
1982 - Allow class names as part of filter rules, eg
1983 (MFSupercuts) && (MHillas.fSize>100)
1984
1985 - fixed a lot of stuff to allow all programs to process MonteCarlo
1986 camera files.
1987
1988 - enhanced possibility to debug reading of resource file
1989
1990 - MDataChain should handle priorities of operator more
1991 accurate now
1992
1993 - completely revised the container in which the signal is stored
1994 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
1995 * the new implementation is faster and
1996 * needs less storage space
1997
1998 - FIRST version which can process Monte Carlos through the
1999 whole chain of programs (callisto, star, etc)
2000
2001 - implemented new image parameters for the border length of
2002 the shower image (MNewImagePar2)
2003
2004 - implemented wobble-mode in ganymed
2005
2006 - new class (MJOptimize) taking care of all optimization processes
2007
2008
2009
2010 *** Version 0.8.6 (2004/10/05)
2011
2012 - New combined signal and time extractor
2013 MExtractTimeAndChargeDigitalFilter
2014
2015 - The Report for the trigger section in the CC run summary has been
2016 updated, and now the IPRs (Individual Pixel Rates) are available.
2017
2018 - new macros for database interaction: filldotrun.C, filldotrbk.C
2019
2020 - added new program which can convert colored output which was redirected
2021 into a file back into colored text (for example to display it with
2022 more): showlog
2023
2024 - added new program to display an MStatusArray of plots (stored with
2025 MStatusDisplay) from a file: showplot
2026
2027 - Added support for Sequences (MSequence). Sequences are blocks of run
2028 files containing the same calibration and belonging to the same
2029 source
2030
2031 - Added a new task (MTaskEnv) which can be used in setup files to switch
2032 between different tasks (for example to choose a signal extractor)
2033
2034 - Implemented automatic file splitting in MWriteRootFile
2035
2036 - After image cleaning an island index is assigned to all used pixels.
2037 The index corresponds to the order of the islands in size.
2038
2039 - added a cleaning which takes signal height _and_ arrival time into
2040 account: probability cleaning (for more details see MImgCleanStd)
2041
2042 - added a cleaning which takes takes the absolute number of photons
2043 times the area ratio as cleaning level
2044 (for more details see MImgCleanStd)
2045
2046 - Changed calculation of image parameters such, that it can be done
2047 for all used pixels or the pixels with a defined island index only
2048
2049 - implemented new image parameters displaying the number of islands,
2050 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2051
2052 - event display in executable changed to support also calibrated files
2053 (done with MJCalibrateSignal)
2054
2055 - added program doing the calibration and the signal extraction
2056 and signal calibration: callisto Most part of the setup is done
2057 by a resource file: callisto.rc
2058
2059 - implemented support for pixels with negative IDs (Raw file format
2060 version 4)
2061
2062 - implemented an new option in merpp (--auto-time) to get the time
2063 range for cc and/or caco data from the run header of the raw data
2064
2065 - New star-program (star and MJStar). Taking calibrated data from
2066 callisto/MJCalibrateSignal as input. The setup is done through
2067 a resource file: star.rc
2068
2069 - Added possibility to setup the eventloop in the mars-executable
2070 Camera Display by a resource file: mars.rc
2071
2072 - The the mars-executable Camera Display can now also read
2073 calibrated data files written by callisto/MJCalibrateSignal
2074
2075 - Added a new class which can calculate the source position in
2076 the camera from a pointing model known to be correct and
2077 the pointing model used for observations (MSrcPosFromModel)
2078
2079 - added a new version of the class calculating the effective on-time
2080 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2081 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2082 MHTimeDiffTheta.
2083
2084 - added the possibility to count how often a signal is above (or
2085 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2086 can replace MHTriggerLvl0)
2087
2088 - added ore convinient ways to set the axis-titles of your histograms
2089 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2090 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2091
2092
2093
2094 *** Version 0.8.5 (2004/08/06)
2095
2096 - new Signal Extractors: MExtractFixedWindowSpline
2097 and MExtractAmplitudeSpline
2098
2099 - implementes interleave in merpp to be able to merpp parts of a file
2100
2101 - implemented force-functionality to merpp
2102
2103 - star display to display star catalogs (MAstroCatalog)
2104
2105 - star display to 'mirror' stars to the camera (MAstroCamera)
2106
2107 - implemented a new cleaning option which allows cleaning scaled with
2108 the real ratio of the rms depending on the pixel size, not only the
2109 square root of the pixelsize (MImgCleanStd, MCameraData)
2110
2111 - removed obsolete MBlind* classes
2112
2113 - Signal extractor taking the AB flag into account implemented (this makes
2114 an odd number of slices for signal extraction possible
2115 (MExtractSignalABcorr)
2116
2117 - implemented a class extracting the pedestal from the raw-data (events)
2118 itself using empty lo-gain (MpedCalcFromLoGain)
2119
2120 - Added mean values to MPedPhotCam
2121
2122 - Added Makefile for Darwin (this OS is NOT officially supported!)
2123
2124
2125
2126 *** Version 0.8.4 (2004/04/19)
2127
2128 - new fast arrival time extractor using cubic splines:
2129 MExtractTimeFastSpline
2130
2131 - implementes multi-argument support in MDataChain
2132 ("pow(a, b)")
2133
2134 - implemented double reference support in MDataChain
2135 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2136
2137 - added support in MF for expressiond like
2138 "MHillas.fWidth<2*<MHillas.fLength"
2139
2140 - MDataChain is now able to support variables like [0], [1], ...
2141 which can be used in fit functions as parameters. The interface
2142 is implemented through the new virtual function
2143 MParContainer::SetVariables
2144
2145 - added new class MArrivalTimeCam/MArrivalTimePix:
2146 Storage containers to hold the ArrivalTime of the camera/pixel
2147
2148 - added new classes for the calibration of relative arrival times:
2149 MCalibrationRelTimePix and MCalibrationRelTimeCam
2150
2151 - added new classes to extract the signal of the blind pixel and the
2152 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2153
2154 - added new classes for the bad-pixels treatment (MBadPixels*)
2155 which are more powerfull than the old ones (MBlindPixel*)
2156 and will replace them.
2157
2158 - added filter against cosmics: MFCosmics
2159
2160 - added new class MArrivalTimeCalc2:
2161 Calculates the arrival time as the signal weighted mean of the time
2162 slices in the maximum window
2163
2164 - added a new macro call pointspreadfucntion.C that fits with a 2D
2165 gaussian the DC spot for an star. It gives you the RMS of
2166 the PSF and the center of the star, very useful for misspointing
2167 studies.
2168
2169 - added support for multi-telescope camera files. Added classes
2170 MStereoCalc and MStereoPar, classes to calculate and store shower
2171 parameters calculated from the data of two telescopes, for the MC
2172 studies regarding the MAGIC clone.
2173
2174 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2175 MC data calibrated in photons instead of ADC counts.
2176
2177 - added three macros to show the calibration and analysis chain of
2178 MC data. The macro starmc.C does both calibration and analysis, producing
2179 an output containing Hillas parameters for each event. The macro
2180 mccalibrate.C does just the calibration and writes out a file containing
2181 pixel information in photons instead of FADC data. The macro starmc2.C
2182 reads in such a file and produces an output with Hillas parameters.
2183
2184 - added MPedPhotCalc to compute pedestals in units of photons, see
2185 macro pedphotcalc.C
2186
2187 - added all class to perform the calibration, see macro calibration.C
2188
2189 - added class MFFT to perform Fast Fourier Transforms
2190
2191 - added class MSimulatedAnnealing to perform simulated annealing
2192 minimizations
2193
2194 - added new macro bootcampstandardanalysis.C which holds the skeleton
2195 of the analysis chain discussed in the december bootcamp.
2196
2197 - added support for DAQ raw data file format V2
2198
2199 - implemented an arbitrary time stamp for the events from raw-data
2200 files with file version<3. It is calculated from the run number,
2201 the date of start and the FADC clock tick from the first module
2202
2203 - implemented the correct decoding of the event time-stamp
2204 coming from the DAQ for raw-data files with file-version>2
2205
2206 - added a new classes storing the pedestals in units of photons:
2207 MPedPhotPix, MPedPhotCam
2208
2209 - added support for DC current files from the camera control
2210
2211 - added support for start- and stop-time when merpping report files
2212
2213 - added MReportCC storing the weather data from the CC-REPORT
2214
2215 - added class to fill trainings and test matrices (MTFillMatrix)
2216
2217 - added a filter performing a software trigger (MFSoftwareTrigger)
2218
2219 - Added classes to perform parts of the standard analysis (Jobs):
2220 + MJPedestals
2221 + MJCalibration
2222 + MJExtractSignal
2223 Note: All of them are preliminary!
2224
2225 - Added Iterator to iterate over files giving only the run-number
2226
2227 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2228 the evolution of a sector vs time
2229
2230
2231
2232 *** Version 0.8.3 (2003/12/05)
2233
2234 - adapted Random Forest classes to allow the use with MC
2235 multi-telescope files which can be produced with the coming
2236 camera version 0.7.
2237
2238 - added classes to read and interprete central control report files
2239 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2240
2241 - enhanced merpp (the executable) to support .raw and .rep files.
2242
2243 - added classes for light calibration (MCalibration* and
2244 MHCalibration*) by Markus Gaug. Further work has to be and will
2245 be done soon.
2246
2247 - Added a preliminary 'synchronizer' (MReadReports) which will
2248 replace MReadMarsFile as soon as it is finished.
2249
2250 - Added a tutorial macro demonstrating how report files are merpped
2251 and how they can be read from the root file in the correct order
2252 of time (readrep.C)
2253
2254 - Added a generalized histogram (similar to MH3) called MVsTime
2255 which allows to plot variables (or rules - MDataChain - of
2256 variables) vs time. For an example have a look at tempvstime.C.
2257
2258 - Changed the name of the event trees:
2259 + Events --> Events
2260 + PedEvents --> Pedestals
2261 + CalEvents --> Calibration
2262
2263 - changed name of MTime in the event trees from MRawEvtTime to MTime
2264
2265 - added displaying the sector indices to the mars event display
2266
2267 - Magic Online Analysis (MOnA) implemented in a first version
2268 (see mona.cc, MOnlineDump and MOnlineDisplay)
2269
2270 - added classes to calculate event rate
2271 (preliminary: MEventRateCalc, MEventRate)
2272
2273 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2274
2275 - added classes dealing with the telescope pointing position (MPointing*)
2276
2277 - implemented the 'final' Mars time stamp based on some experiences with
2278 the new 'Synchonizer'
2279
2280
2281
2282 *** Version 0.8.2 (2003/11/10)
2283
2284 - accelerated standard analysis by a factor of 6-8 ...
2285 + doing precalculations in MGeomCam for the pixel area ratio
2286 + creating a look up table for the single pixels in MCerPhotEvt
2287
2288 - added task to calculates weights in case you want to 'change'
2289 the energy spectrum of a monte carlo file
2290 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2291
2292 - added a new executable star which implements the
2293 star.C macro as precompiled executable. Currently a flexible
2294 setup is not possible, but a 'input card' setup will follow.
2295
2296 - Starting to implement Multi-Telescope-Support based on the
2297 upcomming camera version 0.7. The base for a general support
2298 is implemented and the star-functionality is proven to work.
2299
2300 - Replaced Event-Display in and Camera-Display in the Mars GUI
2301 executable by a more convinient display base on MStatusDisplay.
2302
2303 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2304
2305
2306
2307 *** Version 0.8.1 (2003/10/20)
2308
2309 - added signal subtraction for pure on data by means of fitting
2310 the background in the off region or by performing a combined
2311 signal/background fit. Provides necessary histograms for
2312 obtaining energy spectra and a light curve.
2313
2314 - added classes to perform and study the selection of the
2315 2nd Level Trigger on MC data (example in triglvl2.C macro)
2316
2317 - added pedestal calculation
2318
2319 - implemented "democratic cleaning" (tail cut value proportional
2320 to pixel area) according to Wolfgang's suggestion.
2321
2322 - added Sigmabar treatment (calculation and basic histogramming)
2323
2324 - added basic routines to apply padding
2325
2326 - added first implementation of MARS-based source visibility plotter
2327 (needs to be linked against slalib, preliminary version)
2328
2329 - enhanced functionality of data chains: random numbers, conversion
2330 functions and access to MHMatrix objects
2331
2332 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2333 numbers under certain circumstances (runs with 0 events included)
2334
2335 - fixed a bug in the general filter MF (didn't work on some systems
2336 at all)
2337
2338 - fixed a bug in chaining files, which caused the analysis to crash or
2339 ignore files
2340
2341 - implemented more geometry classes describing the parameters used
2342 to simulate the PMT camera
2343
2344 - added new Monte Carlo classes containing the setup of the different
2345 programs in the MC chain.
2346
2347 - added a (preliminary) general task to evaluate chi-square of a given
2348 parameter in an eventloop.
2349
2350 - first implementation of a container describing the observatory
2351 location (Long, Lat, etc)
2352
2353 - added Random Forest - method for g/h-separation
2354
2355 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2356 (this means, that it is compiling, but not yet fully tested)
2357
2358 - added a new status display which can show the present status
2359 of histograms while an eventloop is running (MStatusDisplay,
2360 an example can be found at status.C)
2361
2362 - reorganized directories:
2363 classes describing the image --> mimage
2364 classes containing Monte Carlo Histograms --> mhistmc
2365 classes for Random Forest method --> mranforest
2366
2367 - added (event-)weights to fill histograms
2368
2369 - colors in logging output to screen
2370
2371 - changes to the Image Parameter declaration:
2372 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2373 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2374 + MHillasExt now derives from MParContainer instead of MHillas
2375 --> Files written with the old definition are more or less unreadable
2376
2377 - reading of reflector files
2378
2379 - display data from reflector files in the camera
2380
2381 - implemented currents (and display them in the camera)
2382
2383 - logarithmic scale in camera
2384
2385 - added class to iterate through directory contents (MDirIter)
2386
2387
2388
2389 *** Version 0.8 (2002/11/18)
2390
2391 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2392
2393 - corrected 48(!) wrong entries in the Next Neighbor table of the
2394 Magic Camera (all in the inner part of the outer ring, mostly
2395 missing a single NN)
2396
2397 - Fixed a bug in the table describing the Next Neighbours of the
2398 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2399 have any neighbour)
2400
2401 - changed trigrate.C: now it calculates the pure NSB triggers from
2402 a camera file (generated with no showers), so there is no need
2403 to introduce them by hand in the BgR array (for more details
2404 please ask Abelardo)
2405
2406 - added MHHadronness (and MHadronness) as a general facility to evaluate
2407 the quality of a gamma-hadron seperation method
2408
2409 - changed MWriteAsciiFile to accept rules (MDataChain)
2410
2411 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2412 must be replaced by calles to MWriteAsciiFile::AddColumn and
2413 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2414 changed.
2415
2416 - Implemented generalized event-matrices (one row per event)
2417 (MHMatrix)
2418
2419 - implemented the one dimensional composite probabilities
2420 (MHCompProb, MCompProbCalc, comprob.C)
2421
2422 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2423 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2424
2425 - Added a camera display displaying the pixel numbers to the
2426 event display gui.
2427
2428 - Added Monte Carlo Informations to event display gui
2429
2430 - Changed the camera display to display the pixel numbering
2431
2432 - Added three buttons to the camera display to change the palette
2433
2434 - Added the number of used and core pixels after image cleaning
2435 to MHillas
2436
2437 - Changed the algorithm used in MHillas according to TDAS 02-03
2438
2439 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2440
2441 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2442
2443 - Added fCosDeltaAlpha to MHillasSrc
2444
2445 - The numbers of photons used to calculate fConc and fConc1 in
2446 MHillasExt are now scaled with the pixel size, so that one get
2447 a four times smaller value for the bigger pixels in the outer ring.
2448
2449 - added new task to smooth the camera contents (MCameraSmooth)
2450
2451 - added possibility to use interpolated pixel values for blind pixels
2452 instead of removing it completely from the analysis
2453
2454 - Implemented the possibility to save the whole eventloop with
2455 its setup to a file. This information can be read and from
2456 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2457 and MEvtLoop::MakeMacro. If you find something not working, please
2458 report - this stuff is still in a beta phase.
2459
2460 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2461 file having crab starfield, but also for all following files - fixed
2462
2463 - MTaskList::PrintStatistics can now be instructud to print also the
2464 title, too: use PrintStatistics(0, kTRUE)
2465
2466 - Changed the image cleaning so that pixels with to many 'used'
2467 neighbors are left used (to get rid of 'holes' in events)
2468
2469 - Introduced more output to the camera displays
2470
2471 - Added an array of histograms (eg one hist per run), MHArray
2472
2473 - Added a _preliminary_ version of the reader for CT1 PreProc files
2474 (MCT1ReadPreProc)
2475
2476 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2477 (thanks to Raquel)
2478
2479 - added the first energy estimator (MEnergyEstParam, estimate.C,
2480 estfit.C) using a parametrization
2481
2482 - Added some new Monte Carlo paremeter containers used to store
2483 setup information from the MC chain (MMcConfigRunHeader,
2484 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2485
2486
2487
2488 *** Version 0.7 (2002/04/30)
2489
2490 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2491 the pedestal mean value was saved incorrectly. For files from
2492 this versions we substract 0.5 from the pedestal mean.
2493 WARNING: This may effect your results, so don't wonder...
2494
2495 - First implementation of an algorithm using only triggered events
2496 for the collection area calculation
2497
2498 - Ascii Output can now also be used for parameter containers which
2499 doesn't overload MParCointainer::AsciiWrite
2500
2501 - The Ascii Output is now also capable of writing single data members
2502 of one container
2503
2504 - You are now able to change the order of the values written to the
2505 ascii file
2506
2507 - You can now specify a conversion factor for each data member written
2508 to an ascii file. This may be usefull to change the units of the
2509 data member (eg. degrees instead of millimeters in case of the
2510 hillas parameters)
2511
2512 - Replaced old MHillas by a new structure which allows you to extend
2513 the parameters stored in MHillas very easily:
2514 see MHillas and MHillasExt
2515
2516 - Added classes to handle source dependancy of image parameters:
2517 see MHillasSrc
2518
2519 - Added container (MBinning) to have a standard input for the binning
2520 in different histograms (eg. the Energy bins should be the same in
2521 all histograms)
2522
2523 - Changed Hillas histograms from mm to deg
2524
2525 - Added the flexible binning to the hillas histograms
2526
2527 - Added a filter for the alpha parameter (MFAlpha)
2528
2529 - It is now possible to write single data members of a class object to
2530 an output stream instead of the whole container only
2531
2532 - Added a generalized filter for a data member:
2533 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2534
2535 - Added a generalized Filter parser for more difficult filter rules
2536 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2537
2538 - Added new Monte Carlo histograms:
2539 MHMcEnergyImpact and MHMcEfficiency
2540
2541 - Added many new histograms needed for the flux calculation.
2542
2543 - Added a generalized histograms which can fill and show up to three
2544 data members in either a one-, two- or three-dimensional histogram, eg:
2545 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2546
2547 - Added:
2548 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2549 * calculation of <Theta> as a function of time (MHThetabarTime)
2550 they are needed in the flux calculation in
2551 order to select for a given bin in Theta (or time) the appropriate
2552 effective collection area, which is assumed to be given as a function
2553 of Theta and the true energy
2554
2555 - Added calculation of the migration matrix in the energy
2556 (MHMcEnergyMigration):
2557 the migration matrix describes the migration from the true (E_true)
2558 to the estimated energy (E_est); it is needed to determine the
2559 distribution of E_true from the measured distribution of E_est
2560 by unfolding
2561
2562 - changed the color palette in the camera display to DeapSea.
2563
2564
2565
2566 *** Version 0.6 (2002/01/15)
2567
2568 - Introduce the option of disable pixels (MBlindPixels and
2569 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2570 able to deal with Star Field NSB.
2571
2572 - Fixed a bug in the pedestals substraction
2573
2574 - Introduced verbosity levels
2575
2576 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2577
2578 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2579 work correctly (thanks to Abelardo)
2580
2581 - Introduced correct treatment of the diffuse Night Sky Background
2582 and NSB (MMcPedestalNSB)
2583
2584 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2585
2586 - Introduced MMcRunHeaders which contains monte carlo run informations
2587
2588 - Added a 'Print'-Task (MPrint) which calls the Print function
2589 of a parameter container for each event
2590
2591 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2592
2593 - changes to be more efficient with root 3.02/06
2594
2595 - root 3.02/06 fixes:
2596 + the memory leak when reading MRawEvtData
2597 + loosing more time than necessary to update the progress bar
2598
2599 - MWriteAsciiFile is now capable of writing more than one container
2600 in a line. For example: To be able to write Monte Carlo and
2601 Hillas values (energy and alpha) in one line.
2602
2603
2604
2605 *** Version 0.5 (2001/11/06)
2606
2607 - Added new GUI functionality (Analysis)
2608
2609 - Added a camera display to be able to display events in the camera
2610 together with the calculated hillas ellipse
2611
2612 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2613 object at any state of the analysis, so that the output are several
2614 states
2615
2616 - Fixed a bug in the collection area error calculation
2617 (Thanks to Ciro and Abelardo)
2618
2619 - Fixed a bug which causes merpp to crash in some environments
2620
2621 - Implemented auto enabling scheme for Branches to speed up reading
2622 a lot (see MReadTree and MTask)
2623
2624 - Fixed a bug in the Histogram classes which caused histograms to
2625 be written to a file by MWriteRootFile without request
2626
2627 - changed the object I/O from the old stylish root I/O to the new
2628 'auto evolution scheme' This was done only for classes which are not
2629 yet used in Monte Carlo files, so that these files are still readable.
2630
2631 - Added support for a progress bar in MEvtLoop and MReadTree
2632 (see the Analysis Window in Mars for an example)
2633
2634 - Fixed a bug in the package creation which disturbed the conversion
2635 between a mars version unpacked from a tar file and the repository.
2636
2637 - Changed the code to writer merpped (converted into root format)
2638 raw files, to get faster (around 10%)
2639
2640
2641
2642 *** Version 0.4 (2001/09/20)
2643
2644 - This release is made to compile on a root version >= 3.00
2645
2646 - Fixed a bug which causes MReadTree to read the first file only
2647
2648 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2649
2650 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2651
2652 - Added a task to write several container to a root file (MWriteRootFile)
2653
2654 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2655
2656 - Added calculation of the collection area (MMcCollectionAreaCalc)
2657
2658 - fixed some bugs in the Hillas calculation
2659
2660 - added filters to be able to control the task execution dependent on
2661 a parameter (for example: the number of level 1 triggers in a MC-file)
2662
2663
2664
2665 *** Version 0.3 (2001/04/23)
2666
2667 - Many demo macros added
2668
2669 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2670
2671 - Hillas Calculation added
2672
2673 - Standard image cleaning available
2674
2675 - MReadTree is now able to handle more than one file
2676 (Remark: of the same structure)
2677
2678 - Now we are able to display events in a first version of the
2679 Camera event display. To do this we must run the macro
2680 "macros/readCT1.C" to read data from CT1.
2681
2682
2683
2684 *** Version 0.2 (2001/01/24)
2685
2686 - First Implementation of a Gui to read the raw data. Start the
2687 gui with the command mars.
2688
2689
2690
2691 *** Version 0.1 (2000/12/20)
2692
2693 - First official release 0.1
2694
2695 - Changes:
2696
2697 + changed calling style of MRawPixelIterator from do...while to
2698 while-loop
Note: See TracBrowser for help on using the repository browser.