source: trunk/MagicSoft/Mars/NEWS@ 8932

Last change on this file since 8932 was 8932, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 116.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;Database
6
7 * introduced average temperature and wind speed from star-files
8
9 * introduced the ratio of accepted calibration events in the
10 calibration run
11
12 * introduced the average rates of the different trigger pattern,
13 e.g. the rate of pedestal and calibration events, from the signal-file
14
15 ;general
16
17 * fixed GroupBy options in plot*.C macros
18
19 * only display KVA points (not the Tuorla points) in plotoptical.C
20
21 * all programs now allow to add resources to the ones from the resource
22 file or overwrite them from the command line. This can be done like this
23 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
24 if something seems to be wrong you can debug what the program is doing
25 using the option --debug-env=3
26
27 * increased the diversity of debug levels. That also means that with -v3
28 you get now less output, i.e. only the output which is important for
29 an analysis. To get more output which helps for debugging try 4, 5 and 6.
30
31 * fixed a problem in the task synchronizing the reading of the reports
32 and the data stream. The effect was that in some circumstances the last
33 events of some trees could have been skipped. Since this is only a
34 very tiny part of the data no severe effect to your analysis results
35 is expected (an exception might be very short, i.e. singel runs,
36 datasets).
37
38 * Dataset file now allow to include the sequence file directly within
39 the dataset file and also allow to exclude single runs from the dataset.
40 (for more details see Class reference of MDataSet)
41
42 * Sequence files now allow for excluding runs from the analysis
43 (for more details see Class reference of MSequence)
44
45 * added code to process the sum-trigger flag
46
47 * the histogram classes MH3 and MHn now support profile histograms
48
49 * the histogram classes MH3 and MHn now support labels at the axis
50
51 * the Random Forest Train-classes (MJTRain*) now store the used datasets
52 in the output file
53
54 * the MFMagicCuts have a new option to allow a linear area cut (for
55 special studies)
56
57 * The liniking of the shared object is now done into a file defined
58 by ´mktemp´. This should be a local file system which accelerates
59 liniking a lot.
60
61 * The code has been prepared for compilation with root 5.18/00d
62
63 ;merpp
64
65 * Implemented cc file version 2008-20-02/0
66
67 ;callisto
68
69 * in the pedestal processing now at least 50 processed events are
70 required for succeeding.
71
72 * the signal and calib files now contain also the sequence information
73
74 * the two MPedestalCam in the calib file now have proper names
75 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
76
77 * Both pedestal cams now conatain the number of events processed
78
79 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
80 i.e. for the extraction of the calibration pulses basically the average
81 over all events of the first slice instead of all slices was used.
82 Since pedestal and calibration constants are continously recalculated
83 this only effected the very first events of every sequence.
84
85 * For the extraction of the position of the maximum sample now the
86 extraction range is set automatically to the extraction window,
87 before the whole accessible range was used.
88
89 * If the number of samples in the events and the number of samples
90 in the run-header disagrees now an error is raised (this can
91 happen in not well simulated Monte Carlo files)
92
93 * In the case of MUX-data pedestal events with the lvl1 trigger flag
94 could survive into the pedestal calculation -- fixed.
95
96 * Tab "TrigPat" added showing the distribution of the trigger pattern
97 as found in the run-files (normalized with the run length)
98
99 * The selection of events from the trigger pattern has been improved.
100 If the trigger pattern is corrupted events won't pass anymore.
101
102 * Added a new command line option --dev-null to suppress output of
103 Y-files (this is useful for test cases)
104
105 ;star
106
107 * the star file now contains also the sequence information
108
109 * Added a new command line option --dev-null to suppress output of
110 I-files (this is useful for test cases)
111
112 * Tab "Rate" added showing the distribution of the trigger pattern
113 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
114 the Y-files (normalized with the run length)
115
116 * The effective on-time calculation doesn't use events with only
117 sum-trigger anymore
118
119 ;ganymed/sponde
120
121 * Now data points are even shown correctly if they have error bars larger
122 than one sigma. Points with null or negative significances are omitted.
123
124 * DrawNicePlot now allows to set a projection range
125
126 ;sponde
127
128 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
129
130 * a new option "--force-runtime" is available. In case of very short
131 datasets (for light-curves) which are in the order of a few
132 minutes the calculated effective on-time is not very acurate because
133 it is quantizised in th eorder of a minute. Therefore you can switch
134 to using the real run-time instead (remakrt: this ignores any
135 dead-time!)
136
137 * a more analytical way is used to "fill" Monte Carlos into regions
138 of impact parameters which have not been simulated because the
139 trigger efficiency is assumed to be 0.
140
141 * estimated sensitivity curves for hi and lo zenith angles are shown
142 scaled to the correct observation time and collection area
143
144 * the Monte Carlo events after cuts are now written to the output file
145 if an output file given
146
147
148
149 *** Version 2.0 (2007/09/03)
150
151 - database: the position used for the pulse pos check was missing
152 in the callisto output and could thus not be filled into the DB.
153 Also the old values seemed not exactly the PulsePos used for
154 teh check.
155
156 - general: Resource file now allow an Include-Resource, i.e. you can
157 read a resource file with default settings, include it in your
158 resource file and overwrite the settings in your file. More than
159 one include file is allowed. Inclusions can be iterative.
160 Include: mydefaults.rc yourdefaults.rc
161 The resources in the first file have higher priority than the
162 second file.
163
164 - general: Now the output files (calib*.root, etc) also contain the
165 resource file (to check it open it in the TBrowser and choose Print()
166 from the context menu)
167
168 - general: Dataset files now allow to overwrite the default path
169 to search for sequence and data files. Note, that the program
170 option and individual resources will overwrite it. For example:
171 SequencePath: /magic/montecarlo/sequences
172 DataPath: /magic/montecarlo/star
173
174 - general: Fixed a problem with variables in MDataPhrase. It seems
175 that only optimdisp (didn't work) was effected.
176
177 - general: Some improvements to the optim and train processing. For
178 example the ststud window now got a proper title.
179
180 - general: The "Status Display: " was removed from the window title
181 within an Eventloop.
182
183 - general: added a new flexible histogram-class (MHn) which can be used
184 for example in testing after optimizations or training to produce
185 user defined histograms.
186
187 - general: The Random Forest now allows attaching an evaluation
188 function which is applied to its output. This allows to train
189 on whatever you like (eg. train on log10(energy), but return
190 energy)
191
192 - general: The Random Forest training of energy (trainenergy.c) and
193 disp (traindisp.C) has been improved by more graphical output to
194 judge the result.
195
196 - general: The training of energy (trainenergy.C) has been improved
197 a lot by training on a different quantity than energy. It gives
198 a result which is highly independant of the source spectrum
199 and shows lower bias than all other options.
200
201 - general: Dataset files are allowed to contain collections of
202 datasets. For more details see the class reference of MDataSet.
203
204 - general: The default WobbleMode in a datset file now (if not
205 overwritten) is "auto", i.e. wobble mode is set if the dataset
206 doesn't contain off-sequences.
207
208 - merpp: Merpp can read file format version 9 now. Please realize
209 that for file format version 9 the extraction range is different
210 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
211 the first and last 15 slices have been removed from all MUX data.
212
213 - mars: Similar to writing movies you can now select events which
214 should be displayed in your display. Therefore add the following
215 lines to your mars.rc:
216 MFEvtNumber.FileName: ganymed00223552.root
217 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
218 The input file can be a ganymed-file after (ganymed*.root) or
219 before (ganymed*-summary.root) file. For example to select all events
220 from your on sample after cuts (excluding the ThetaSq cut) use
221 MFEvtNumber.Selector: DataType.fVal>0.5
222 To show all events from your on-sample after quality cuts
223 use the summary file instead.
224
225 - mars: new ways to call mars are implemented. Instead
226 of calling
227 mars filename.root
228 you can now also use
229 mars sequence.txt
230 or
231 mars sequence.txt inputpath
232 or replace sequence.txt by the sequence number if the default
233 sequence file should be used.
234
235 - mars: The default size has been increased
236
237 - mars: There are two new heckboxes which allow to switch off
238 the calculated image parameters
239
240 - callisto: was broken for MCs... fixed.
241
242 - callisto: improved calculation of spline coefficients a lot. This
243 leads to a further improvement of the event rate calibrating MUX
244 data of about 15% (175evt/s instead of 150evt/s)
245
246 - callisto: finally the raw data we read is now real 16bit (with
247 10bit precision) for MUX data and not a stripped 8bit number
248 anymore. Due to scaling of the numbers (without precision loss
249 into an [0-256[ range, the final numbers for pedestal, pedestalrms
250 and extacted signal don't change. However, at all places where
251 raw data is directly accessed (eg. saturation and variation
252 limits in the signal- and pedestal-extraction) the numbers
253 refer still to the data's 16bit range.
254
255 - callisto: The maximum arrival time difference used in the bad
256 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
257 for both, old FADC and MUX-FADC, data.
258
259 - callisto: Be aware that callisto is now calibrating the arrival time
260 in nanoseconds rather than time slices. Also all following tasks
261 have been changed to assume ns units now. If you star data
262 calibrated with an older version it might be necessary to adapt
263 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
264 to obtain optimal results. The plot in the PulsePos tab
265 will now be in ns, too. This might also mean that the Muon
266 analysis in star might not work as perfect as expected as long
267 as old files read in.
268
269 - callisto: The calibration constants of earlier updates got lost
270 somehow. All constants have been updated.
271
272 - star: The PSF is now determined from the profile of the ArcWidth
273 instead of arcwidth/radius. The old way gave to much weight
274 to the bins with low statistics. The reference lines have been
275 updated.
276
277 - star: For speed reasons events suitable for the muon analysis
278 are now also preselected by fConcCOG<0.1 which seems to be a very
279 good preselector for muons.
280
281 - star: is now calculating a new timing parameter the Slope along
282 the major and minor axis of the shower. Therefore a numerical
283 solution of a line-fit is used. To use MHillasExt.fSlopeLong
284 and MHillasExt.fSlopeTrans don't forget to multiply it with
285 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
286
287 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
288 have been removed from MNewImagePar. They have never been good for
289 anything.
290
291 - star: Implemented a new recursive algorithm which is supposed to be
292 faster. Also implemented new cleaning oiptions, which are:
293 + CleanLevel0:
294 The cleaning level above single core pixels can be kept
295 + KeepIsolatedPixels:
296 Define whether single core pixels should be kept
297 + TimeLevel1:
298 The coincidence window in nanoseconds to single used neighbors
299 + TimeLevel2:
300 The coincidence window in nanoseconds to two used neighbors
301 + PostCleanType:
302 MOde in which a time dependent post cleaning should be applied
303 0: No post cleaning
304 1: Require for each used pixels at least one used neighbor
305 within a time-window of CleanLevel1
306 2: Require for each used pixels at least two used neighbor
307 within a time-window of CleanLevel2
308 3: Require first two and second one used neighbor
309 within a time-window of CleanLevel1 and fCleanLevel2
310 respectively
311 + RecoverIsolatedPixels:
312 - recoveres isolated core pixels if they have a used neighbor
313
314 - mars/star: The new default cleaning is:
315 + CleanLevel1: 6.0
316 + CleanLevel2: 3.0
317 + CleanTime1: 1.75
318 + CleanTime2: 1.75
319 + PostCleanType: 3
320
321 - star/ganymed: The old spark-cuts have been replaced by new ones.
322 These new spark cuts have been cross checked with the sequences
323 84720 (before splitter), 101041 (after splitter) and 223539 (new
324 FADCs). In all cases they seperate pretty well, but of course not
325 perfect. Monte Carlos have suggested to tighten the cuts a little
326 bit further at low sizes. This has been done.
327
328 - ganymed: IMPORTANT - The spark cuts have been changed to match
329 all available data more or less well. This might mean that for
330 YOUR data there are still sparks visible.
331 Whenever you do an analysis you have to make sure that NO sparks
332 survive your cuts!
333
334 - ganymed: The old hadronness and size cuts have gotten new indices
335 (10, 11). The old indices 8 and 9 now mean an additional condition
336 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
337 If you want to switch off this cut just move the line far away enough,
338 e.g. by setting c[9] to -500. Please update your ganymed.rc files
339 accordingly!
340 The unit of c[9] is deg. It is the dist at which your cut will
341 cross the slope==0. The unit of the slope is ns/deg. So if
342 you readin files calibrated with an older Mars-version you
343 have to adapt the default value for c[9] to the FADCs:
344 - Multiply by two for the MUX FADCs (run number > 200.000)
345 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
346 - Multiply by 42 for the meaning of life (run number = 200.000)
347
348 - ganymed: The old Cut0 is now called CutQ and is calculated before
349 the source position is caluclated. If you need a quality cut
350 including source dependant data (be very carefull with this!)
351 you have to use Cut0 instead.
352
353 - ganymed: now properly supports three off regions in wobble mode.
354 It will be the default from now on in ganymed_wobble.rc. To change
355 the number of off-regions use
356 NumOffSourcePositions: 1
357 in your ganymed.rc. Also by default no off-theta cut will be done
358 anymore so that you will get a background level higher than the
359 signal level in your ThetaSq plot for ThetaSq>0.2.
360 Due to this be carefull changing the scaling mode away from
361 "None". You will underestimate your signal if your scale interval
362 is not properly set.
363 (Rem: ThetaSqN is no longer needed)
364
365 - ganymed: is now storing the events of all (on- and off-)
366 source positions even in the case of more than one off-source
367 position. This should allow sponde to work properly and the
368 energy estimation is done correctly in all cases (without any
369 "nearest position" trick)
370
371 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
372 with a real pointing model for the starguider is done, calibrated
373 with more than thousand tpoints taken from this date on.
374
375 - ganymed: was broken for Wobble-MCs... fixed.
376
377 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
378 has changed. Note that your old ganymed.rc will be incompatible
379 with the new algorithms! Please check the ganymed.rc files and
380 the class description of MFMagicCuts for more information.
381 It is recommended at the moment to use identical Disp-Parametrizations
382 for on/off- and wobble-mode. If cuts are optimized only
383 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
384 should be optimized. All other values should be kept as they are.
385 If you want to do an anylsis without timing a parameters, you can
386 switch off the timing cuts by seeting parameter 7 to a very small
387 value (eg. -99). To remove the slope parameter from the disp
388 paremtrization set parameter 8 to 0.
389
390 - ganymed: The distribution of observation time versus zenith
391 angle is now shown for off- AND on-data.
392
393 - ganymed: The contents of the source position plot are no longer
394 averaged, thus a lot of (fake) events between the two wobble
395 positions have disappeared.
396
397 - ganymed: There is a new tab "CutT" it contains the VsSize plots
398 with the CutT, whihc is defined in ganymed.rc, applied. It
399 is resonable to use your theta-cut for it, to see if there is
400 something strange (sparks!) in your signal-region.
401
402 - ganymed: To choose a dataset from a collection in a dataset file
403 use the new command line option "--dataset=12345"
404
405 - optim, sponde: should now properly support three off-regions.
406 Just produce your ganymed summary files with three off-regions.
407 optim and sponde will automatically get all off events from
408 all off-regions from this file. Please do not forget to
409 set the scaling in optimwobble.C properly:
410 fit.SetScaleUser(1./3);
411 it is not yet read in automatically (will follow soon).
412 In the case of fixed Scale you can also use
413 cuts.SetThetaCut(MFMagicCuts::kOn);
414 no off-cut needed.
415 Be carefull in case of three off-regions when switching on
416 scale mode. Make sure that the scale interval is set correctly.
417
418 - sponde: sponde.rc and sponde_onoff.rc are now idetical
419
420 - sponde: the resouce files have been rewritten with a lot of
421 comments and a well working parametrization for an energy estimator
422
423 - sponde: In the estimated energy versus monte carlo energy plot the
424 contents where exchanged.... fixed.
425
426 - sponde: the so called "accurate"-mode has been removed. It didn't
427 give any improvement in accuracy, only decreased execution speed.
428
429 - sponde: the so called "simple"-mode has been removed. It didn't
430 give any improvement in simple.
431
432 - sponde: the so called "refill"-mode has been removed. It was anyhow
433 not implemented.
434
435 - sponde: now checks whether the theta distribution of your on-data
436 and the theta-distribution of your Monte Carlo sample (after
437 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
438 sample is incomplete) execution is stopped. Execution can be forced
439 using the new option --force-theta. Use this option with care!
440
441 - sponde: Proper collection areas can now be constructed also from
442 Monte Carlo samples generated with different maximum impact
443 parameters. Note that in previous version you neither got
444 a warning or failure, nor was there any obvious sign that the
445 collection area was overestimated due to usage of files with
446 different maximum impact parameters.
447
448 - sponde: If MC files with different lower energy limits are used
449 the primary MC spectrum is artificially completed down to the
450 lowest energy used at all. WARNING: that this gives correct
451 collection areas ONLY if none of the events in this region would
452 survive your cuts at all.
453
454 - sponde: the output file now contains more information about
455 the spectrum (eg. the full 2D collection area histogram).
456 Note, that this information can only be written to the file
457 if it is stored automatically via command line argument.
458 If you only store the status display from within the display
459 the information is lost.
460
461 - sponde: added a new tab "Disp". It shows the residual of the disp
462 (Disp-Dist) versus several parameters and it is meant to judge the
463 quality of the disp estimator. In the ideal case the residual is zero
464 and doesn't depend on any variable. The tab is displayed after
465 CutQ and Cut0.
466
467 - sponde: added a new tab "Energy". It shows the residual of the
468 energy (lg(estimated energy)-lg(monte carlo energy)) versus
469 several parameters and it is meant to judge the quality of the
470 energy estimator. In the ideal case the residual is zero
471 and doesn't depend on any variable. In reality even a good estimator
472 can show residuals versus Monte Carlo energy. The tab is displayed
473 after all cuts.
474
475 - sponde: added a new tab "EventDist" showing the unweighted real
476 absolute number of events of your sample after cuts. This tells
477 you how many events with this energy you had in your MC files.
478 The same information you get from the error bars of the weighted
479 histograms, but this is less intuitive.
480
481 - sponde: The spectrum plots now show the crab- and 1553-spectrum
482 for comparison. It is not meant to show these curves in
483 publications, they are only for production.
484
485 - sponde: The OriginalMC tree with the events produced by corsika
486 is now processed only once
487
488 - sponde: Finally fixed most annoying bug, which has effected the
489 last bin of the collection area. It was the problem that binnings
490 of root histograms are from 1 to n (included) but there was a C-like
491 loop in sponde from 0 to n (excluded). Now the loop also includes
492 correctly under- and overflow-bins. The worse thing with this is,
493 that for the events in the highest bin not only the bin-content
494 was wrong, but also the weights applied to these events, which could
495 in pricipal effect also other parts of the distribution (eg. due
496 to energy estimation). Fortunately it effected only a few events
497 in most cases.
498
499
500
501 *** Version 1.2 (2007/05/14)
502
503 - database: The database now has two new values Unsuitable50 and
504 Unsuitable01. They express the number of pixels which are
505 unsuitable for more than 50%, respectively more than 1%, of
506 all calibrated event. It is a more accurate number than the
507 previously used numbers, because they only take the first
508 calibration (ignoring the interleaved calibrations) into account.
509
510 - database: The database now has two other new values UnsuitableMax and
511 DeadMax. They express the maximum number of pixels which were
512 unsuitable, respectively dead, during the sequence. Because
513 of high pedestal rms (cars passing) a few events with very high
514 numbers of unsuitable pixels can happen. Not to suffer from this
515 effect we don't take the highest 0.1% of the numbers into account.
516
517 - general: fixed a bug which caused callisto and star to stop working
518 properly because the callisto output was currupted
519
520 - general: a script called scripts/makemovie has been added which
521 simplified the process of producing several movies from a single
522 sequence with different setup.
523
524 - callisto: Some more code cleanup. Started to remove old obsolete
525 code from cvs.
526
527 - callisto: The extraction of the pedestal with the extractor was
528 not random. It seems that extracting at one position is still biased
529 (for example in the first or last slices we could still suffer from
530 switching noise) Now it is completely random.
531
532 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
533 pedestal files) individual pixels could be skipped due to high
534 variations. This was already the case for the pedestal extraction
535 from the lo-gains since the beginning and properly handled
536 there, but was introduced in the extraction from the pedestal files
537 a while ago. To calculate the average value it was still divided
538 by the number of events procesed not by the number of summands
539 really summed. This let to a pedestal which was a tiny amount too
540 small (for a few piels in the order of 0.1%). This led to an slightly
541 positive offset of the randomly extracted pedestal for a few pixels.
542 I doubt that this has a big effect on the result, because the effect
543 on the individual numbers is quite small. Due to this it is suggested
544 that you rerun your calibration to make sure you are without any
545 avoidable bias.
546
547 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
548 the median rms of the absolute arrival time and expressed in significance
549 levels. This replaces the old meaning of an abolute upper limit. An
550 absolute upper limit doesn't make much sense, because in our data
551 all arrival times are shifted at the same time (in fact it might be
552 a shift of the artificial trigger w.r.t. to the light flash).
553
554 - callisto: Added a new tab "BadPixTm" which shows the time evolution
555 of the number of unsuitable pixels over the whole sequence. This
556 is usefull mainly to judge if an intermediate calibration had
557 problems.
558
559 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
560 of the number of dead pixels over the whole sequence. Dead pixels
561 in this context are unmapped pixels, i.e. pixels which could not
562 be interpolated, and thus are ignored in the further analysis.
563
564 - callisto: It is now possible to use the position of the maximum
565 of the spline as arrival time instead of the leading edge even
566 when using the integral for the signal. Therefor set the extraction
567 type to kIntegralRel ("IntegralRelative") and the relative height
568 ("HeightTm") to -1:
569 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
570 MJPedestalC1.ExtractSignal.HeightTm: -1
571
572
573
574
575 *** Version 1.1 (2007/04/27)
576
577 - general: The new class MGeomCamDwarf contains the camera geometry
578 for our prefered Dwarf camera and can be used to create general
579 geometries of roundish or hexagonal cameras.
580
581 - mars: The default cleaning is now abolute 8.5/4.0.
582
583 - mars: The resource file mars.rc now contains examples for MUX data
584
585 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
586 data containing only 10-bit information is still cooked down to
587 8-bit, by cutting away the lowest 8-bit.
588
589 - merpp: When reading raw data the data is now stored in a single
590 array. The lo-gain array is obsolete. The interface stays the same.
591
592 - callisto: To process the new MUX data use the resource file
593 callisto_mux.rc
594
595 - callisto: The -root and -raw options to read merpped raw data have
596 been removed
597
598 - callisto: If the -mc option is given the sequence-name can now be
599 replaced by the MC sequence number
600
601 - callisto: If the sequence file contains "MonteCarlo: Yes" the
602 -mc option can now be omitted
603
604 - callisto: Started further simplification by removing obsolete
605 dependancies on MCalibIntensity*Cams.
606
607 - callisto: removed unsused intensity calibration from MJCalibration
608 for further simplification
609
610 - callisto: for simplification removed references to
611 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
612 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
613 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
614 (this should at minimum change nothing at all, and at maximum
615 improve thing if these containers where somewhere not handled
616 properly)
617
618 - callisto: Added the option to write an event movie. Please use
619 this option with care (huge files) but exessively to understand
620 our events. For further documentation please refer to the
621 IACT wiki
622 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
623
624 - callisto: Improved binning for the pulse position check histogram
625
626 - callisto: The code calculating the pulse position checknow takes
627 the pedestal into account
628
629 - callisto: The arrival time is now stored with full precision this
630 helps to get rid of artefacts in histograms. For the signal this
631 is not necessray because it is displayed in log-scale anyhow
632
633 - callisto: Fixed a problem with internal exclusions. Pixels which
634 have once been marked as unsuitable didn't get the necessary
635 histograms filled anymore to be rechecked with each interleaved
636 calibration.
637
638 - callisto: The relative arrival time resolution (the rms of the
639 relative arrival time offset) is now checked against its
640 median and the median deviation, instead of the average
641 plus an absolute offset.
642
643 - callisto: The relative arrival time offset is now calculated
644 w.r.t. its median not w.r.t. to an artificial reference pixel.
645
646 - callisto: The relative time calibration now marks pixels with
647 outlaying offset as unsuitable
648
649 - callisto: The interleaved relative time calibration has been switched
650 on. The advantage is that pixels which are marked as outliers
651 now can recover. An improvement over time is not expected, because
652 the relative time calibration seems stable.
653
654 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
655 option can now be omitted.
656
657 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
658 or the option "-mc" is specified as default the monte carlo datacenter
659 paths (/magic/montecarlo/...) are used if not overwritten in the
660 dataset file.
661
662 - ganymed: The output files now contain run- and event-number for all
663 events, accessible as RunNumber.fVal and EvtNumber.fVal
664
665 - ganymed: Added a plot showing the source position in the camera also
666 for wobble mode
667
668 - ganymed: In addition to the existing task which can be setup to
669 be executed after Cut1 a final task called "EstimateEnergy"
670 has been added, executed before writing the final output
671 (ganymed00000000.root). The task setup in all three cases
672 can be choosen individually. (For all three(!) cases you
673 can for example choose MRanForestCalc. For examples see all
674 sponde*.rc and all ganymed*rc)
675
676 - ganymed: If a container "MEstimatedEnergy" is found in the
677 parameter list (eg. because it was setup by MEstimateEnergy)
678 it will be written to the output file.
679
680
681
682 *** Version 1.0 (2007/02/16)
683
684 - database: Website to plot values from the database has been added.
685
686 - database: The rate of spark events as found by star is now kept
687 and the rate after cleaning is now with spark events subtracted
688
689 - general: The changes to the interpretation of phrases lead to
690 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
691
692 - general: Added example files how you can create your own calendar
693 (eg. as christmas present) with Mars. Just run
694 root macros/tutorials/calendar.C
695
696 - general: Added a possibility to display grouped data in the plotdb.C
697 macro (and similar macros). This allows to plot hourly, nightly,
698 weekly, monthly and yearly averages.
699 For more details see the plotall function of the macro
700
701 - general: fixed the error display of the camera display. It showed
702 wrong results.
703
704 - general: fixed a memory leak when reading many MStatusDisplays
705
706 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
707 between a spherical and a parabolic mirror
708
709 - callisto: We have a new pulse position check which takes the properties
710 of the extractor automatically into account. So no need to set
711 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
712 left is done. If possible the lo-gain extraction start and hi-gain
713 extraction end is changed accordingly. If no proper extraction range
714 can be set (hi-gain too much to the left) an error is raised.
715
716 - callisto: New swapped pixels have been found and corrected
717
718 - callisto: Redone the signal extraction this includes:
719 + Unified the algorithms to extract the pedestal for all pedestal
720 extractions done
721 + Unification of hi- and lo-gain into one array
722 + Unification of hi- and lo-gain extraction for Spline and
723 Digital Filter (means now exactly the same algorithm is used,
724 not a copy-and-pasted one)
725 + Store pedestal subtracted data in a common place
726 + Improved extraction algorithms. If the algorithms search a
727 maximum but don't find one they don't return the maximum anymore
728 + Improved the extraction such that a information for signal
729 and time which is consistent is returned
730 + replaced the numerical spline with a (not slower) analytical
731 solution
732 + Lowered the saturation limit from 250 to 245 to make sure that
733 we are far away in all pixels from problems with the clock-noise
734 + The start of the lo-gain extraction is calculated from the hi-gain
735 arrival time. In case of saturation an estimation is used.
736 + the hi-gain window was extended to slice 16. This allows extraction
737 of very late pulses in single pixels or of huge hadron showers.
738 + Now uses the lo-gain extraction range for pedestal extraction,
739 not the hi-gain range in the lo-gain
740
741 - callisto: New hi-/lo-gain calibration constants have been produced
742 for all periods from the statistic of the whole period. They are
743 now used automatically depending on the periods. The old constants
744 where deviation in avarega about 2%-3%. The constants are very
745 stable from period to period (<<1%) except for exchanged channels.
746 In a few cases the constants used so far were off by 1%-2% (maybe
747 temperature effects?)
748
749 - callisto: To gain obsolete space we do not write the
750 MPedestalFundamental anymore. Also calibration and bad pixel
751 treatment is not done for it anymore because it has never been used.
752
753 - callisto: Fixed a bug in the seuqence handling which caused the
754 light condition to be ignored
755
756 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
757 basically the same as "Cleaned" but the distribution devided into
758 the events fullfilling a spark cut or being rejected by it.
759 This cut can be changed from star.rc (see example inside) by
760 the "SparkCut" directive
761
762 - star: Star displays now the average individual pixel-rate (IPR) versus
763 time and the average discriminator threshold (DT) of all pixels.
764
765 - optim: fixed a problem with the optim-macros which was due to a bug
766 in the new phrase parsing
767
768 - ganymed: To get a nice FalseSource plot (instead of the all-information
769 debug plot displayed as a standard plot) use the context menu
770 somewhere between the two upper plots, click on "DrawNicePlot"
771 and enjoy the result. (It is the same context menu which contains
772 the other options)
773 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
774
775 - ganymed/optim/train: The cut program, trainings- and optimization
776 macros could run with less files found than expected from the
777 sequence-files. No the execution is stopped in this case.
778
779 - ganymed: now stores the dataset in the output file with all information
780 contained (as sequence number, sequence path, data path) so that the
781 used dataset file can be recreated complete from the output
782
783 - sponde: now also allows the uasge of random forest
784
785 - sponde: added a plot showing the cut efficiency
786
787 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
788 errors (eg. effecting the collection area) because the errors of the
789 two histograms were swapped in the calculation, which makes a difference
790 in the case the histograms contains weighted events. Aditionally the
791 totalarea was incorrectly taken into account, which results in too small
792 errors, which makes a difference at low statistics were the errors
793 or the collection area dominate.
794
795
796
797 *** Version 0.10.3 (2006/10/23)
798
799 - database: Implemented ObservationMode flag in websites.
800
801 - database: For sequences there is now also the stoptime available on the
802 websites.
803
804 - database: Removed ManuallyChanged flag from sequence-info websites,
805 as it is not needed anymore with the new sequence building algorithm.
806
807 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
808 Class for calculation of confidence intervals (upper limits).
809 Use model 3 or 4 for upper limit calculation for MAGIC observations.
810 Please read the class instruction of TRolke for more information.
811
812 - general: The programs now return 0xfe if the requested resource file
813 doesn't exist.
814
815 - general: Errors comming from root itself are now not output to
816 stderr anymore but to our default (colored) log-stream.
817
818 - general: Changed the interface to TFormula such that now everything
819 is parsed by TFormula, which should allow to use phrases even
820 without paranthesis correctly parsed.
821
822 - callisto: replaced the AdHoc number of effective integration slices
823 in the digital filter by an average of the correct number, averaged
824 over all possible set of weights. This also gives correct numbers
825 for the lo-gains which were totally wrong before.
826
827 - callisto: drastically reduced memory consumption by not storing
828 all intermediate calibration results in memory anymore (we might
829 write them into a file in the future)
830
831 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
832 debug plot displayed as a standard plot) use the context menu
833 somewhere between the two upper plots, click on "DrawNicePlot"
834 and enjoy the result. (It is the same context menu which contains
835 the "DrawAll" option)
836 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
837
838
839
840 *** Version 0.10.2 (2006/10/15)
841
842 - general: changed the building of the sequence files such, that
843 the source-/project name in case of wobble-sources is not the
844 source/project of the first data run anymore but the new generalized
845 wobble source/project
846
847 - general: Added some functions to MAstro to calculate sun and
848 moon properties
849
850 - general: Added two new macros (starvisday.C and starvisyear.C)
851 which allow to plot the visibility of several stars in one day
852 or of one star along one year
853
854
855
856 *** Version 0.10.1 (2006/10/11)
857
858 - general: HTML logging output was distorted... fixed.
859
860 - general: Changed the writing of the sequencefiles such that only
861 as many pedestal files as giving at least 1000 pedestal events which
862 are nearby the first calibration run are used as pedestal runs
863
864 - sponde: In the calculation of the collection area(s) and the
865 distribution for MOnte Carlo and estimated energy the error
866 calculation was wrong because root didn't take the errors
867 properly into account... fixed.
868
869
870
871 *** Version 0.10 (2006/10/10)
872
873 - general: all executables now check consistency of the root version
874 installed with the root version used for compilation. The return
875 code in this case is 255.
876
877 - general: The algorithm to build seqeunces has been redesigned
878 completly. It is now more flexible in terms of a resource file
879 resources/sequences.rc which can be used to partly overwrite
880 the default algorithm and defined the important part of the
881 algorithm. It also takes correctly into account several ways
882 of taking wobble-data. Currently the new algorithm doesn't take
883 the number of pedestal events anymore into account (so a sequence
884 could have much less than 1000 pedestal events and data runs are
885 no-more used instead)
886
887 - general: a lot of small changes to make the code compatible with
888 root 5.12/00 and gcc 4.1
889
890 - general: Fixed some warnings thrown if more warnings are switched
891 on in the compiler
892
893 - general: Added a function to MMath which returns the Median of
894 the distribution abs(y[i]-median) but at 68:32 division instead
895 of 50:50, which is somehow the median counterpart of the rms.
896
897 - general: MAstroCatalog allows now to read calatog files (as bsc5)
898 even if they are compressed with gzip (recommended compression
899 is with "-1")
900
901 - showplot:
902 + batch mode creation of image files now works with root 5.12/00
903 + added support for writing bmp (though it never produces
904 bmp which can be read by programs like xv or gimp)
905 + added support for xml
906 + added new option to start the display with a different size, by
907 --display-width=nnn or --display-height=nnn
908 + added options to define the canvas size when the display is started
909 --canvas-width=nnn or --canvas-height=nnn
910 the option can also be used for batch-mode conversion
911 + added an option which automatically fits the display size to the
912 desktop-size: --auto-size
913
914 - merpp: didn't recognize files with the extension .raw.gz - fixed.
915
916 - merpp: allow the reports to have 1000ms due to a bug in the camera
917 program.
918
919 - callisto: New swapped pixels have been found and corrected. For
920 details see MRawRunHeader::FixAssignment()
921
922 - callisto: Callisto now raises an error if one of the input files could
923 not be opened.
924
925 - callisto: In some rare cases it could happen that in the signal
926 extraction of the digital filter the extractor returned nonsense
927 results due a wrong initializion of a variable (this happens in
928 cases in which the extracted signal is exactly zero or the
929 digital filter couldn't slide because of a too small extraction
930 window, which could happen in the lo-gain extraction)
931
932 - callisto: The lo-gains have been marked as valid in some cases
933 when they got not extracted at all (deltsumlo=deltatimelo=0) because
934 the allowed extraction range (fLoGainLast-fLoGainFirst) was
935 smaller than the number of slices (fLoGainWindowSize) needed
936 by the lo-gain extractor
937
938 - callisto: Updated absolute calibration constants (muon calibration)
939
940 - callisto: fixed a bug which caused the hi-gain saturation not
941 to be handled properly in the spline (the position of the
942 saturation was calculated incorrectly)
943
944 - callisto: fixed a bug which gave weird results if hi- _and_
945 lo-gain could not be extracted properly. In some cases hi-
946 and lo-gain have not been extracted at all and the random result
947 got calibrated. In other cases the hi-gain was saturating and the
948 lo-gain has not been extracted. For this a completly arbitraty
949 scale factor was applied to the result from extracting the
950 charge of the saturating hi-gain.
951
952 - callisto: improves handling of extracted signal if lo- and/or
953 hi-gain could not be extracted properly. If no appropriate
954 calibration of either the signal or the arrival time is possible
955 the pixel is now markes as unsuitable instead of estimated.
956
957 - callisto: Fixed a problem in the spline extraction which gave
958 weird results if the signal was extracted from the first (and
959 highest) slice (as a workaround extraction from the first
960 slice has been forbidden)
961
962 - callisto: Fixed a bug regarding the use of the QE which doesn't
963 effect the result because the default is used anyhow.
964 (The bug was there since 14/07/2005)
965
966 - callisto: Changed the default for fgLoGainStartShift to -2.4
967
968 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
969 factors to be always 10 for all pixels as soon as the first
970 calibration update has happend.
971
972 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
973 was off by more than one slice (which gives wrong values for
974 pixels which have saturated the hi-gain) This was a problem
975 mainly for timing studies, not so much for the automatic standard
976 analysis. Also the values for the Spline have been changed slightly:
977 + Digital Filter from 1.70 to 0.95
978 + Spline from 1.39 to 1.30
979 The numbers were sorted out by an extensive test in the
980 test-database.
981
982 - callisto: Removed the tab showing the average calibrated arrival
983 time. It never gave useful information.
984
985 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
986 lo-gain pulse for data pulses if hi- and lo-gain have saturated
987 and both were extracted because the hi-gain was above the
988 LoGainSwitch.
989
990 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
991 lo-gain pulse position (after application of LoGainOffset, which
992 means in the ideal case it is 0) for data pulses if hi- and lo-gain
993 have saturated and both were extracted because the hi-gain was above
994 the LoGainSwitch.
995
996 - callisto: After extensive tests a new threshold level for determination
997 of the pulse position has been found at 50phe. This is due to the
998 fact that for lower pulses the arrival time changes its average
999 behaviour dramatically. It tends to the average of the extraction
1000 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1001
1002 - callisto: Added two more plots to the calibration part. The average
1003 extracted signal and the average extracted arrival time as
1004 extracted by the signal extractor (This can help debugging problems
1005 because it doesn't involve a fit)
1006
1007 - star: changed the fit for the effective on time such that initial
1008 values are calculated automatically now instead of using build
1009 in values. This makes the fit more indepedant of the underlaying
1010 rates. With a test of ~350 sequences in the test database it could
1011 be shown that the new fit gives the same result +/-1sek.
1012 The highest deviation was +5s the lowest -10s. You can now control
1013 the bahaviour with two resource values:
1014 MHEffectiveOnTime.FistBin: 3
1015 MHEffectiveOnTime.NumEvents: 12000
1016 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1017 from the resulting gamma candidates
1018
1019 - star: The Center histogram in MHHillas is now by default displayed
1020 with the colz draw-option
1021
1022 - ganymed: now produces valid error codes if failed
1023
1024 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1025 with the option "hadronness" instead of "area" or "both" if
1026 you want to use both cuts. The hadronness cut includes a fixed
1027 cut in hadronness (index 8) and a fixed cut in size (index 9).
1028
1029 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1030 the M3Long of the anti source to be not properly evaluated
1031 (actually is was evaluated as a unique random number) in case
1032 of optimization with anti-theta cut switched on. This might have
1033 lead to improper, but not necessarily wrong, optimization results.
1034
1035 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1036 how to use random forest
1037
1038 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1039 ganymed_onoff.rc. Seems to be unintentional that they were different.
1040
1041 - sponde: Since the introduction of the possibility to define a
1042 normalization energy instead of using the integral the default
1043 was not using the integral anymore but a normalization energy of
1044 1GeV. It is now the integral again.
1045
1046 - sponde: Fixed a problem in the weighting which did not allow
1047 a MC slope of -1.
1048
1049
1050
1051 *** Version 0.9.6 (2006/05/24)
1052
1053 - general: changed the binning of the azimuthal profile of the camera
1054 such that it is aligned with the 60deg boundaries.
1055
1056 - merpp: better handling of problems with the TH, TD part of the
1057 CC-REPORT for files older than 200507190 and 200412210
1058 respectively
1059
1060 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1061
1062 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1063
1064 - callisto: if an arrival time is extracted outside the fadc range is
1065 was set to the boundary before. Now a random number is assigned
1066 instead to avoid unfortunate coincidences of arrival times just
1067 by this arbitrary value.
1068
1069 - callisto: added a new option to callisto.rc which allows
1070 to set the maximum arrival time difference allowed for the
1071 badpixel algorithm to determin whether a pixels belongs to a shower:
1072 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1073
1074 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1075 to 0.9 as suggested by Stefan due to a recent study on the fraction
1076 of pixels surviving the image cleaning
1077
1078 - callisto: switched off error in case of "pulse is too much to the left"
1079
1080 - callisto: The extraction window is not adapted anymore. This means that
1081 the pulse is extracted from the full range. The draw-back is that the
1082 background (pedestal) will become slightly higher. Switching on/off
1083 the PulsePosCheck in the callisto.rc only effects filling the
1084 histograms.
1085 WARNING: If the pulse is too much to the left data is calibrated!
1086 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1087 in the database to make sure that your data is valid!
1088
1089 - star: Show also the number of stars correlated correctly by the
1090 starguider
1091
1092 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1093 than one off-source region in wobble-mode. To use it add the following to
1094 your ganymed_wobble.rc:
1095 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1096 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1097 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1098 + Cut1.ThetaCut: None
1099 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1100
1101 - ganymed: in the case the latest report is older than a default (currently
1102 one minute) and the current report will be skip the starguider
1103 correction and calibration will be reset. The maximum age can be
1104 setup from ganymed.rc by (minutes):
1105 MPointingDevCalc.MaxAge: 1.5
1106
1107 - ganymed: A first implementation showing all size-bins for the theta-sq
1108 resp. alpha-plots in a single tab automatically
1109
1110
1111
1112 *** Version 0.9.5.1 (2006/05/05)
1113
1114 - general: Added a new option "zdiff" to the Makefile which runs
1115 "cvs diff" as "make diff" would do, but with compression
1116
1117 - general: accelerated MTFillMatrix (used for eample in all training
1118 and optimization macros) by skipping some obsolete calles in the
1119 eventloop the first and second loop could be accelerated by ~20%
1120
1121 - general: Added a missing feature in the MFilterList class which
1122 prevented MFEnergySlope from working correctly in trainenergy.C
1123
1124 - general: Accelerated the random forest training and usage a bit
1125
1126 - merpp: Adapted to new raw data file format version 6
1127
1128 - merpp: fixed a problem with reading the starguider reports
1129 after 6.3.2006
1130
1131 - callisto: At some times six pixels had to be exchanged manually in the
1132 data. If the pixels to be swaped are both not found, an error was raised
1133 and calibration was stopped. Now it is assumed they are intentially not
1134 mapped and the Error has been changed to a Warning.
1135
1136 - star: Added new image cleaning based on the arrival time of the shower.
1137 The new cleaning can be accessed using the parameter "Time" instead of
1138 the the old one (like "Absolute) in the star.rc-file.
1139 Recommended parameters:
1140 + MImgCleanStd.CleanLevel1: 8.2
1141 + MImgCleanStd.CleanLevel2: 5
1142 + MImgCleanStd.CleanRings: 2
1143 + MImgCleanStd.KeepSinglePixels: No
1144
1145 - star: Simplified the calculation of the effective on time. By letting
1146 the fit start in the third bin the result should become more stable.
1147 The fit quality is now ignored for the theta-plot which is not used
1148 in the analysis later. Still better pre-cut which, for example,
1149 remove events triggered by car-light (rate changing on a short
1150 time-scale) are missing.
1151
1152 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1153 for optimization (kWeakSource) which is suggested by the Berlin
1154 people for weak sources.
1155
1156 - macros: plotdb.C:
1157 + if no dataset and no time-interval is given only sequences with
1158 an effective on-time above five minutes are plotted anymore
1159 + added a new tab "RelTime" displaying the relative on-time
1160 (effective on-time divided by the observation time)
1161
1162 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1163 the optimization became a lot faster
1164
1165 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1166 To display them just delete the pads displayed on top.
1167
1168 - ganymed: fixed a bug which could cause strange behaviour in wobble
1169 mode if no starguider information was available due to an incorrect
1170 initialization of the starguider calibration
1171
1172 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1173 be changed from within the plot. It can also be setup from the
1174 resource file using:
1175 + MHDisp.fScaleMin: 0.325
1176 + MHDisp.fScaleMax: 0.475
1177
1178 - ganymed, showplot: Fixed a problem with the fit to the off-data
1179 (HistOff) which could cause a time lag or an inifinite loop.
1180 The bug did not effect the results at all.
1181
1182 - sponde: Added a new tab showing the effective collection area after
1183 trigger (including the software trigger)
1184
1185 - sponde: MMcSpectrumWeight has a new option which allows to define
1186 the scaling factor not by the integral of the events but at
1187 a defined energy:
1188 e.g. MMcSpectrumWeight.NormEnergy: 200
1189
1190 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1191 eventloops the loop could be accelerated by ~20%
1192
1193
1194
1195 *** Version 0.9.5 (2006/03/13)
1196
1197 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1198 and added the standard Disp-parametrization
1199
1200 - macros: added a new macro datacenter/macros/plotstat.C allowing
1201 to plot statistics about the data processing
1202
1203 - macros: added a new macro to plot the muon correction coefficients
1204 versus period (macros/plot/mucal.C)
1205
1206 - showplot: path inflation for ganymed files was broken
1207
1208 - callisto: Fixed an important bug. When the number of saturating pixels
1209 were calculated the bad pixel information already available from the
1210 calibration was ignored. This yields wrong values in case pixels
1211 are broken and saturate all the time or randomly.
1212
1213 - callisto: Updated Muon calibration constants. Spline data now also uses
1214 different values for different periods
1215
1216 - star: The time-evolution shown in the effective on-time plot now displays
1217 the axis range (if there are no holes it should be similar to the
1218 effective on-time)
1219
1220 - star: Added two new image parameters:
1221 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1222 the three pixels next to the center of gravity and the size
1223 + MNewImagePar.fConcCore: The ratio of the signals of all
1224 pixels inside or touching the ellipse and the size
1225
1226 - ganymed: now stops in requested source isn't found in catalog file
1227
1228 - ganymed: Many improvements to the phi-plot in wobble mode:
1229 + with a template the ideal background is displayed
1230 + a possible camera inhomogeneity is taken into account
1231 + the anti theta cut is better supported
1232 + the phi cut is automatically calculated from the theta cut
1233 See the examples in ganymed_wobble.rc for more details.
1234
1235 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1236 times the bin-width instead of the absolute energy
1237
1238 - ganymed: New cuts for on/off and wobble mode
1239
1240 - ganymed: The smearing of the False Source plot has been increased
1241 to 0.06
1242
1243 - ganymed: The starguider calibration can now be changed from the
1244 resource file.
1245 See the examples in ganymed*.rc for more details.
1246
1247 - ganymed: added a new option for on-/off-observations
1248 MJCut.RandomSourcePosition
1249 If switched on the distribution of observation time of the source
1250 position in the camera is calculated from the on-data and randomly
1251 applied with this distrbution to the off-data.
1252
1253 - ganymed: by skipping some obsolete calles in the eventloop the
1254 first and second loop could be accelerated by ~20%
1255
1256 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1257 position in the off-data randomly according to its distribution in the
1258 on-data.
1259
1260
1261
1262 *** Version 0.9.4.3 (2006/02/13)
1263
1264 - general: Fixed a bug in most of the programs which prevented the
1265 compile date in the startup message to be displayed
1266
1267 - general: Simplified program calls. The following abbreviations
1268 are now possible:
1269 showlog callisto 55599
1270 showplot signal 55599
1271 star 55599
1272 callisto 55999
1273 ganymed 2
1274 In this cases the corrsponding root-, log-, sequence- or dataset-
1275 filename is automatically compiled using the default datacenter
1276 paths ("/magic/*")
1277
1278 - general: Fixed a long outstanding bug which made axis tick marks
1279 disappear if MDataFormula was used (eg. abs(x))
1280
1281 - general: Updated MMath with new functions to calculate the results of
1282 a exponential, logarithmic and powerlaw fits analytically.
1283
1284 - general: Updated some macros with comments:
1285 + macros/optim/optimdisp.C
1286 + macros/optim/optimenergy.C
1287 + macros/optim/optimwobble.C:
1288
1289 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1290 files) now allows adding a pre-cut like in the optimization. E.g. this
1291 is useful to perform g/h-separation cuts before training the random
1292 forest.
1293
1294 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1295 correctly assigned in the raw data assignement table. A fix to correct
1296 the assignment tabel have been implemented.
1297
1298 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1299 by 90, 180 and 270 deg.
1300
1301 - general: the macro plotdb.C now allows to highlight sequences belonging
1302 to a datset. For more details see the descritions in the macro.
1303
1304 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1305 of the display, it gave wrong results espacially for big sizes.
1306 Now the embedded canvas should always have a ratio width/height=3/2.
1307 The "Size" options have been updated with values fitting the 3/2
1308 size ratio.
1309
1310 - RanForest:
1311 + Updated the random forest classes to support also the
1312 regression method implemented by Thomas H.
1313 + added new tutorial macro how to train the random forest
1314 for energy estimation (macros/optim/rfenergyest.C)
1315 + new classes to train the random forest (still in development)
1316 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1317 + new tutorial macros for random forest training in macros/train
1318 trainenergy.C, traindisp.C, trainseparation.C
1319
1320 - mars: now allows to setup a cut in the resource file mars.rc to choose
1321 the events to be displayed, eg:
1322 Cut.Condition: {0} && {1}
1323 Cut.0: MHillas.fSize>100
1324 Cut.1: MHillas.fSize<900
1325
1326 - merpp: Made aware of the new .rep format 200510250. This includes
1327 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1328 the discriminator thresholds (MCameraTD) and the disciminator
1329 delays (MCameraTD). All of them come with the CC report and are therefor
1330 written to the CC tree.
1331
1332 - callisto: fixed a bug in the calculation of the arrival times in
1333 the Digital Filter. They were all shifted by the same amount
1334 fHiGainFirst. This caused an offset in the order of the position of
1335 the left border of the extraction window in the times calculated
1336 from high-gain and from low-gain. The bug effected only the absolute
1337 arrival times. The bug was there since 30.1.2005.
1338
1339 - callisto: Changed the ExtractionWindow for the pulse position check
1340 such that the camera inhomogeneity becomes as less as possible and
1341 comparable to the pulso position check switched off. More details
1342 on the study will be given at our result web-page.
1343
1344 - ganymed: ganymed.rc, ganymed_onoff.rc:
1345 changed to new cuts trained with 1ES1218 and Crab-data
1346 for maximum sigma*log10(excess)
1347
1348 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1349 a new option was implemented to estimate Disp (CalcDisp)
1350
1351 - ganymed: Implemented two new options which allow
1352 to overwrite the default path to search for the sequence files
1353 --ins=/magic/sequences
1354 and where to search for the image data
1355 --ind=/magic/data/star
1356
1357 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1358 dx/dy from the resource file by
1359 MSrcPosCorrect.Dx
1360 MSrcPosCorrect.Dy
1361
1362 - ganymed: fixed reading the source catalog. Only as many chars
1363 as the requested source name had were compared (If a source
1364 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1365 were requested it could happen that the coordinates of
1366 "1ES1218" were read) The source coordinates are now printed
1367 in addition to its name to the logging output.
1368
1369 - ganymed: changed the background fit in the case of a ThetaSq function
1370 from a polynomial to a exponential, this should give a big improvement
1371 for on-only analysis'
1372
1373 - ganymed/sponde: Calculation of the error of single size-/energy-
1374 bins now uses Li/Ma (5) instead of LiMa (17)
1375
1376 - sponde: Added a plot E^2*dN/dE
1377
1378 - sponde: The energy estimator plot should now show values like
1379 they are commonly used.
1380
1381 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1382 (a powerlaw with cutoff didn't work before)
1383
1384
1385
1386 *** Version 0.9.4.2 (2005/10/01)
1387
1388 - general: added new tutorial macro macros/tutorials/threshold.C:
1389 how to calculate the threshold
1390
1391 - general: added a new game. Start it from the interpreter with
1392 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1393 and MagicReversi)
1394
1395 - general: neighbor pixels in MGeoms are now sorted clockwise
1396
1397 - merpp: made aware of new format 20050829-0
1398
1399 - callisto: New scale factors from muon analysis, stored in new
1400 resource file resources/calibration.rc
1401
1402 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1403 the eventloop if something went wrong. This is necessary for the
1404 automatic processing
1405
1406 - callisto: Implemented a new treatment for the time information
1407 developed by S.Ruegamer, this should give much better response than
1408 the old very primitive algorithm. This is especially important
1409 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1410 treatment was buggy! As neighbor pixels to interpolate the
1411 arrival times always the pixels 0 to 5 were taken)
1412
1413 - callisto: In addition to the new treatment of arrival times the
1414 decision of the treatment whether a pixel contains shower
1415 information or not is used to improve the signal interpolation
1416 further. Previously interpolated pixels showed a non-zero signal
1417 do the peak searching signal extractors. Having a signal pixel
1418 beside raised the signal above the cleaning level. Thus the
1419 pixel survived cleaning to often but with a too low mean signal.
1420 By replacing empty pixels with a gaus (mean and rms from the
1421 corresponding Area entries in MPedPhotCam) this effect can
1422 be supressed.
1423
1424 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1425 got lost when the events were stored by the calibration... fixed.
1426 (This was no problem for normal image cleaning because the pixel
1427 content was artificially set to 0 not surviving standard cleaning
1428 algorithm)
1429
1430 - callisto: Fixed a bug which caused the random and peak-search pedestal
1431 extracted with an extractor to be exchanged for the first (roughly)
1432 500 events (*Extractor and *ExtractorRndm).
1433 (They were simply exchanged in callisto.cc) This bug might have been
1434 introduced in Mars 0.9.4 when the order of calculation of the two
1435 types of pedestal in callisto got exchanged. The bug only effects
1436 the first seconds of data of each sequence.
1437
1438 - star: Taking the arrival time of Muons into account the calculation
1439 of the parameters could be made independant of the noise
1440 (pedestal rms). The dependance was due to the bias of the peak search
1441 extractor. Now only a ZA dependamcy is left which is not yet fully
1442 understood.
1443
1444 - ganymed: The sequences were still not sorted correctly in any case,
1445 because they were sorted by the full qualified path name. Now they
1446 are sorted by their sequence number.
1447
1448 - ganymed: new values for the spark-event-cut
1449
1450 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1451
1452
1453
1454 *** Version 0.9.4.1 (2005/08/18)
1455
1456 - callisto: fixed some problems with the calibration in case of
1457 inteleaved events. Therefor the final and some intermediate
1458 fits are skipped which would take place on partly filled #
1459 histograms and gave wrong results or failed completely.
1460
1461 - callisto: If the intermediate finalization of the histograms
1462 calculating the mean charge of the calibration signal fails
1463 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1464
1465 - ganymed: Fixed some bugs which caused problems in On-only mode.
1466 Still the false source plot doesn't give reasonable results.
1467
1468
1469
1470 *** Version 0.9.4 (2005/08/05)
1471
1472 - general: Fixed the ZA binning. It did not correctly fit the
1473 MC binning
1474
1475 - general: Added a class to correct for the missfocussing in
1476 April (MSrcPosCorrect)
1477
1478 - general: Random Forest energy estimator should now work properly
1479
1480 - general: MHCamera now displays the profiles in deg instead of mm
1481
1482 - general: MH::SetPalette offers a lot of new palettes
1483
1484 - general: MHillas - the case of CorrXY==0 is now handled properly
1485
1486 - general: implemented the possibility to change the line and
1487 marker style of a sky-grid drawn by MAstroCatalog
1488
1489 - general: Runs in sequences and datasets are now automatically
1490 ordered (it is assumed that the order of their filenames correctly
1491 represents the order of observations) to ensure correct reading
1492 of the subsystem data
1493
1494 - general: Runs cannot be added to a sequence twice anymore. Also
1495 Sequences cannot be added twice anymore to a dataset.
1496
1497 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1498 It gave wrong results by 1./2pi
1499
1500 - showplot: got a new option to start a root interpreter, too
1501
1502 - mars: now displays a rough estimate of Disp and the third moment
1503
1504 - mars: now displays the event time MTime if available
1505
1506 - mars: show muon parameters graphically
1507
1508 - mars: now the file to open can be given as commandline
1509 argument
1510
1511 - merpp: Added support for new arehucas version >= 200507190
1512 implementing values for three temperature sensors in the
1513 counting house (MCameraAUX) and the name of the HV settings file
1514 (MCameraHV).
1515
1516 - merrp: Also fixed some problems with wrong versions numbers stated
1517 by arehucas and implemented some fixed for old versions (<200407070)
1518
1519 - callisto: MCalibrationHiLoCam can now be printed from its context
1520 menu, eg in the TBrowser
1521
1522 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1523 - 1.39 (MExtractTimeAndChargeSpline)
1524 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1525 This is important mainly for timing studies.
1526
1527 - callisto: Changed limits in MHCalibrationChargeCalc from
1528 - -100.125 to -98 (fgChargeHiGainFirst)
1529 - 1899.875 to 1902. (fgChargeHiGainLast)
1530 - -100.25 to -99 (fgChargeLoGainFirst)
1531 - 899.75 to 901. (fgChargeLoGainLast)
1532 Introduced new limits:
1533 - fgNumLoGainBlackoutLimit: 0.05
1534 - fgLoGainBlackoutLimit: 3.5
1535 - fgLoGainPickupLimit: 3.5
1536
1537 - callisto: The handling of automatic weights for the digital filter
1538 has been improved. There are now new calibration weights special
1539 for Monte Carlo calibrations.
1540
1541 - callisto: Updated Muon scale with latest results (1% difference
1542 for most data, 5% for Mar/Apr'05)
1543
1544 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1545 was saturated and the blackout-events in the low-gain exceed the
1546 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1547 This excludes those pixels which have a saturating high-gain
1548 channel, but the low-gain switch does not switch often enough
1549 to make the distribution reliable.
1550
1551 - callisto: fix a bug counting the number of saturated events. Up to now,
1552 the number of saturated slices was counted (which is one for a not too
1553 high number), but for some (pathological) pixels, many more slices
1554 saturated and produced wrong limits.
1555
1556 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1557 + MCalibrationRelTimeCam.CheckFitResults: Yes
1558 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1559 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1560 + MCalibrationRelTimeCam.CheckOscillations: Yes
1561
1562 - callisto: introduce max. number of events for intercalibration,
1563 the rest gets skipped. Default: 4096
1564 The calibration causes too many un-reliable pixels if more
1565 than about 5000 events are treated (@500 Hz) because of the
1566 mode hopping of the VCSels. However, in the past, some
1567 calibration runs have been taken (erroneously) with more
1568 than 5000 events, especially the intensity scans where
1569 a good precision is needed.
1570
1571 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1572 photo-electrons for the spline extractor by 1-2% (correctly).
1573
1574 - callisto: The intercalibration is now done using a full f-factor
1575 method instead of a simple update. This makes things slower but
1576 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1577 changes.
1578
1579 - callisto: MPedestalY3 now uses the same extraction range as the data
1580 as calculated by MPedestalY2
1581
1582 - callisto: A check of the fraction of allowed unsuitable (10%) and
1583 unreliable (30%) pixels has been addded when the conversion is
1584 calculated from interleaved events
1585
1586 - star: fixed a bug which caused MEffectiveOnTime containers not to
1587 be written. In the worst case they were skipped almost all, in the
1588 best case they were all ok. It depends on how often the new value
1589 was assigned just with an event which was skipped later by another
1590 task
1591
1592 - star: new histograms MHPointing and MHRate
1593
1594 - star: New tab (Currents) displaying the time evolution of the mean
1595 DC currents
1596
1597 - star: New tab (MeanRms) displaying the time volution of the mean
1598 Pedestal Rms
1599
1600 - star: Output now contains MReportStarguider
1601
1602 - star: Improved muon analysis. Due to the absense of a constant
1603 for the gaus fit for arc width and the fact that the arcwidth
1604 plot was a histogram instead of a profile the resulting psf
1605 became pedestal rms dependant
1606
1607 - ganymed: added new plot (MHPhi) for wobble mode as described in
1608 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1609
1610 - ganymed: corrects now (correctly?) for the misspointing in
1611 May/April 05
1612
1613 - ganymed: Two new default templates for ganymed.rc are avilable:
1614 ganymed_onoff.rc and ganymed_wobble.rc
1615
1616 - ganymed: The first version of MFMagicCuts has been released
1617
1618 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1619
1620 - ganymed, sponde: There are two new options to determin the number
1621 of bins for the signal region (NumBinsSignal) and the number of
1622 total bins (NumBinsTotal) in the MHThetaSq histogram
1623
1624 - ganymed: optimized palettes for MHDisp
1625
1626 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1627 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1628 sqrt(2) to large
1629
1630 - ganymed: The false source plot (MHDisp) is now based on Disp
1631 and a background model determined in the first loop is
1632 subtracted
1633
1634 - ganymed: MFMagicCuts are now available in the cvs. The correct
1635 solution for the disp ambiguity problem is now calculated using
1636 the third moment. The third moment cut therefor is skipped.
1637
1638 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1639 already determined by the third moment along the major axis and
1640 so its actual sign is aligned along the major axis of the shower.
1641
1642 - ganymed: If starguider data is available it is taken into account
1643 when calculating the source position. This is especially important
1644 for wobble data at high zenith angles and culmination data.
1645
1646 - ganymed: If available the starguider data is taken into account as
1647 good as it is possible without a starguider calibration. To switch
1648 it off add
1649 MPointingDevCalc.MaxAbsDev: -1
1650 to your ganymed.rc
1651
1652 - sponde: the zenith angle distribution is now weighted instead of
1653 choosen by default. This gurantees higher statistics in the highest
1654 and lowest energy bins. To switch this behaviour off use...
1655
1656 - sponde: now automatically displays the energy threshold
1657
1658
1659
1660 *** Version 0.9.3 (2005/06/03)
1661
1662 - general: MMcEvt now derived from MMcEvtBasic which should
1663 have no influence on compatibility with older camera files
1664
1665 - general: Implemented a new option to MReadReports which allows
1666 to force reading of the first event of some trees (eg. Drive-tree)
1667 before any other tree.
1668
1669 - general: Made a fix to MPointingPosCalc which assumes that the
1670 run-type is real-data if Process is called before ReInit, such
1671 that also the very first Drive-events in a run are treated
1672 correctly.
1673
1674 - shoplot now displays the filename in the title bar of the window
1675
1676 - merpp: new options: --auto-time-start --auto-time-stop which
1677 allow to cut updating with slow-control at the start- or
1678 (previousle --auto-time only allowed: and) stop-time of
1679 the run stored in the runheader.
1680
1681 - callisto: changed default of fgFallTimeHiGain in
1682 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1683 already set as default in callisto_Dec04Jan05.rc
1684
1685 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1686 now changes the filename for new weights automatically for
1687 cosmics, MC and for different calibration colors.
1688
1689 - callisto: a problem with the order of some code cause the
1690 name of the weights file in MPedestalY2 to be ignored.
1691 Wrongly the calibration_UV weights were used instead
1692 of the cosmics weights set in callisto.rc.
1693
1694 - callisto: should allow ct1 pulser data when the color is
1695 explicitly set also for pretty new runs
1696
1697 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1698 to introduce an additional scale factor (should be around 1)
1699 to adapt for slight deviations in different extractors from
1700 the MC calibration. For MC calibrations the scale factor
1701 is fixed to 1
1702
1703 - callisto: MFCosmics should handle very high signals a bit
1704 more accurate now
1705
1706 - callisto: when calculating the mean pedestal rms for different
1707 pixel sizes or sectors also kUnsuitableEvt is now taken into
1708 account - not only kUnsuitableRun
1709
1710 - callisto: '-raw' option is now the default
1711
1712 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1713 This has the advantage that mean values in the calibration (eg
1714 arrival times) are calculated more accuratly.
1715
1716 - callisto: In the resource file callisto_Dec04Jan05.rc
1717 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1718
1719 - callisto: new Hi-/Lo-Gain intercalibration constants
1720 hilocalib_sp1.root and hilocalib_sp1_mc.root
1721
1722 - callisto: changed default for MJPedestalY2.MaxEvents
1723 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1724
1725 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1726 has changed from 9.0 to 6.0. This is necessary to exclude two very
1727 ringing pixels in September which - when kept - destroy the image
1728 cleaning around them (Markus G.)
1729
1730 - callisto: (!) The Muon analysis of all data taken so far has
1731 suggested that different extractors give slightly different
1732 absolute results after calibration, due to there different
1733 handling of the calibration- and cosmics pulse shape. Although
1734 the over all calibration seems to be a bit to pesimistic (or
1735 the MC seems to be a little bit - 3-5% - too much attenuated).
1736 There for correction factors have been introduced which correct
1737 the calibration constants by
1738 0.956937799 for Digital Filter (callisto.rc)
1739 and
1740 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1741 calibration. The main advantage is, that both data types can
1742 be easily analysed together and compared to the same MC sample.
1743 The factors are choosen such, that the reference is now a
1744 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1745
1746 - star: fixed a bug which caused the first bin of the histograms
1747 vs time to disapear in PostProcess. This gave wrong results
1748 on the screen. The output and all following programs not
1749 directly accessing the histograms haven't been affected
1750
1751 - star, ganymed: Made sure that always the first Drive-tree event
1752 is read and Processed before the first data event was read.
1753
1754 - ganymed: implemented the possibility to replace the standard
1755 false source plot with a different one. For example: If
1756 you want to use a Disp based FS plot use the resource:
1757 NameHistFS: MHDisp
1758 For details about the requirements of these plots look
1759 at the corresponding classes
1760
1761 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1762 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1763 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1764 case MAlphaFitter is setup correctly. For On-Only optimization
1765 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1766 RunOn() instead of Run(). For energy estimation MJOptimize
1767 has been replaced by MJOptimizeEnergy
1768
1769 - sponde: The input MC spectrum can now be weighted to fake a
1770 different spectrum. This is done via MMcSpectrumWeight. For
1771 more details see the class description and sponde.rc
1772
1773 - sponde: The paremeter comparsion plots are not scaled by
1774 their entries anymore. Instead the MC plot is scaled by using
1775 the result spectrum of the analysis. If the input MC spectrum
1776 and the result spectrum has different slopes the absolut
1777 normalization is normally wrong.
1778
1779
1780
1781 *** Version 0.9.2 (2005/05/20)
1782
1783 - general: Changed the default paths for calibrated data and image
1784 files. (The implemented access to these files doesn't yet exist)
1785
1786 - general: support for MRunIter has been removed from the job classes
1787 (use the setter functions of MSeqeunce instead)
1788
1789 - general: ProcessFile has been renamed to Process in all job classes,
1790 because ProcessFile is missleading
1791
1792 - general: The storage of the palette in MHCamera is now possible
1793
1794 - general: new bits describing unsuitable and unreliable pixels have
1795 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1796 kDeadPedestalRms, kFluctuatingArrivalTimes
1797
1798 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1799 versions newer than V200404070
1800
1801 - general: support for cc file versions newer than V200504130. Added
1802 support for active loads (MCameraActiveLoad) and central pixel
1803 (MCameraCentralPixel)
1804
1805 - general: added new histograms for image parameters versus size
1806 (MHVsSize)
1807
1808 - general: The eventloop now automatically calls PrintStatistics
1809
1810 - Status Display: Improved support for printing:
1811 + A default can now be set in .rootrc (for more details see
1812 MStatusDisplay::PrintPS)
1813 + A print dialog is opened so that printer and command line
1814 can be canged
1815
1816 - showlog: improved such that it handles different verbosity levels
1817 more accurate now. This mean you can suppress output when
1818 using showlog.
1819
1820 - showplot: improved
1821 + The new graphics formats have been implemented
1822 (pdf, svg, png, jpg and xpm)
1823 + Implemented an interface for printing. Because you can change
1824 the printing command from the command line you can use all
1825 the nice postscript tool. To print a booklet for example call:
1826 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1827 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1828 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1829
1830 - callisto: fixed a bug in the recognition of the calibration bit
1831 pattern. Concerns only intensity calibration. (The strength of the
1832 intensity has been updated in some cases)
1833
1834 - callisto: add a filter against PIN Diode events when running over
1835 calibration runs since some of the recent calibration runs have
1836 been taken with Pin Diode.
1837
1838 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1839 39943, 44833 in the calibration (MCalibColorSet)
1840
1841 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1842 been set to 1e-18 in callisto_Dec04_Jan05.rc
1843
1844 - callisto: in callisto_Dec04Jan05.rc: set value for
1845 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1846 statistics for the calculation of the mean pulse time
1847 of the cosmisc
1848
1849 - callisto: the charge limit in the calibration has been raised
1850 from 2.5 to 4.5
1851
1852 - callisto: new setup read from callisto.rc
1853 + MCalibCalcFromPast.fNumEventsDump
1854 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1855 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1856
1857 - callisto: MExtractTimeAndChargeSpline extractor:
1858 + The integration ranges were shifted by 0.2 FADC slices to the right.
1859 + unreliable handling of floating point values caused different
1860 results on different platform or with different compiler options:
1861 The new algorithm is numerically exact and more accurate because
1862 it doesn't calculate the integration position by multiple times
1863 adding the step-size (which results in numerical uncertanties
1864 exspecially if multiplied with large numbers)
1865 + A lot of fixes have been introduced which effects integrating the
1866 spline at the edges of the valid range. In this case any memory
1867 was randomly accessed. This behaviour can be tested replacing
1868 all MArrayF by TArrayF which perform a range check (but of course
1869 they are a lot slower)
1870 ! No result obtained with the Spline before can be trusted! Due to
1871 random memory access it might by completely random!
1872
1873 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1874 + extraction range in the high gain to 4.
1875 + weights file to cosmics_weights46.dat
1876
1877 - callisto:
1878 + introduce the check for fluctuating arrival times.
1879 + set charge limit to from 2.5 to 4.5
1880 + introduce asymmetric exclusion due to "deviating number of phes":
1881 Default: -9.0 +4.5
1882 + make deviating number of phes unsuitable (see David's findings).
1883
1884 - callisto: fixed the display of unsuitable pixels. The old change
1885 to a real profile in MHCamera broke it.
1886
1887 - callisto: The cosmics filter is used in MJCalibration now
1888 independant of the pulser color (formaly it was used only for
1889 CT1-pulser data). The threshold of number of max empty pixels
1890 has been raised from 2% to 5% in MJCalibration. The maximum
1891 fraction of rejected event is 50% otherwise the calibration has
1892 failed. The filter now ignores unsuitable pixels.
1893 Setup the filter from callisto.rc using "ContCosmics"
1894 (see MFCosmics::ReadEnv)
1895
1896 - callisto: changed default for fgOffsetFromLogain back
1897 from -2.8 to -1.8 in digital filter.
1898
1899 - callisto: for the common extractors
1900 + MExtractFixedWindow
1901 * MExtractTimeAndChargeSlidingWindow
1902 * MExtractTimeAndChargeSpline
1903 * MExtractTimeAndChargeDigitalFilter
1904 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1905 and fResolutionPerPheLoGain
1906
1907 - callisto: Updated the hi-/lo-gain intercalibration constants
1908 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1909 hilocalib_df6.root
1910
1911 - callisto: The default lo-gain extraction window for the
1912 MExtractTimeAndChargeSlidingWindow extractor has been increased
1913 from 6 to 8 to take the stretch of the pusle into account
1914
1915 - callisto (!!!): fixed an important bug in the setting of the
1916 incoming pedestal pointer to the signal extractor extracting
1917 pedestals. This bug caused the pedestals not to be subtracted
1918 correctly in the calibration afterwards. The effect was about 10%
1919 too high conversion factors for the digital filter and the spline
1920 and more than 40% for the sliding window.
1921 The bug existed since end of February! (Markus G.)
1922
1923 - star: added muon support to star. A new tab "MHMuonPar" is
1924 displayed. The lower right plot is an estimate of the point spread
1925 function. A reference value is displayed. To get the real PSF
1926 you must compare with MC. The setup for the muon analysis
1927 is done in star.rc. More informations can be found in
1928 MHSingleMuon and MHCalibParCalc
1929
1930 - star: The weather data is now displayed in star
1931
1932 - star: MEventRateCalc handles the calculation of the event rate more
1933 accurate now in case of the start of a new run inside a sequence
1934
1935 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1936 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1937 changed only minimally
1938
1939 - ganymed: (MJCut and MJOptimize) now displayes the number of
1940 excess events versus size. The energy estimation is done in
1941 MJSpectrum (sponde)
1942
1943 - ganymed: got support for using other variables than Alpha, eg. Theta.
1944 Therefor you need a class deriving from MHAlpha which supports
1945 this variable (one is already existing: MHTheta, which is now the
1946 default in ganymed). It is setup through ganymed.rc
1947
1948 - added a full featured spectrum program (sponde) which reads
1949 ganymed output and monte carlos and compiles a spectrum
1950
1951
1952
1953 *** Version 0.9.1 (2005/04/14)
1954
1955 - Fix bug on the arrival time reconstruction when using Digital
1956 Filter (in some marginal cases (10%) times were reconstructed shifted
1957 by 0.2 slices)
1958
1959 - all executables now return 2 where in previous versions -1 has
1960 been returned (gave problems with shell-scripts)
1961
1962 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1963 also done with a intercalibration input file
1964
1965 - a bug in the time fine adjustment of the digital filter has been fixed
1966
1967 - a lot of small fixes to calling TPad::Divide with a margin==0
1968
1969 - MStatusDisplay now shows the memory usage
1970
1971 - added a memory leak statistic after the eventloop
1972
1973 - MHadronness replaced by MParameterD
1974
1975 - MEnergyEst replaced by MParameterD
1976
1977 - wobble mode can now be switched on from the data-set
1978
1979 - switched on bad pixel detection for a pedestal level
1980 which is more than 5 times the variance
1981
1982 - Fixed default paths to be correct for the new data center
1983
1984 - Fixed handling of drive data. The pointing position in now
1985 copied to MPointingPos inside star for real and MC events
1986
1987 - made sure, that the sequences in a dataset are sorted by
1988 their number to ensure the correct synchronization
1989
1990 - added all resource files necessary to handle spline extraction
1991 of signal for the late 2004 and the early 2005 data
1992
1993 - update the reference lines for the december data
1994
1995 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1996 This is important for the Dec. and Jan. data where the calibration
1997 pulse position changes much.
1998
1999 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2000 filter. This corrects only an defective extraction of the MC at
2001 low-gain signals lower than 90 phes.
2002
2003 - fixed some slowdown in calibrating data with interleaved events from
2004 Jan and Dec. As a workaround made the pretty palette the default.
2005 The inverse Deep Blue Sea has a bug which slows down long calibration
2006 runs a lot.
2007
2008 - implemented new values from new starguider report as defined
2009 in TDAS00-07 V7.1 (eg SkyBrighness)
2010
2011 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2012 in starguider report (If you merpp the same reports with this version
2013 you'll get the correct units (arcmin) but a different result
2014 than with old versions (wrong units))
2015
2016 - Now the status display can also write PNG, JPEG and XPM (other file
2017 formats are still unsupported by root)
2018
2019 - added a lot of scripts and macros in directory datacenter used
2020 for automatic processing
2021
2022
2023
2024 *** Version 0.9 (2005/03/23)
2025
2026 - Calibration is now done autmatically into photo-electrons like
2027 decided by the Collaboration Board
2028
2029 - Reference lines in the display can be read from resource file
2030
2031 - Interlaced calibration events can be handled by callisto
2032
2033 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2034 and applied in callisto.
2035
2036 - class MJCalibTest can be called by callisto
2037
2038 - callisto can now run with three data types: rawdata, rootdata, MC
2039
2040 - added two classes mreport/MReportStarguider.cc and
2041 mreport/MReportStarguider.h for implementing starguider-data
2042
2043 - the output of merpp-update now contains starguider information:
2044 MReportStarguider and MTimeStarguider
2045
2046 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2047 values were lower than they should. This was more visible for high
2048 energy (Size) events.
2049
2050 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2051
2052 - added a new loop to callisto to support the correct extraction of
2053 the pedestal and pedestal rms through the signal extractor
2054
2055 - added class to perform fourier tranformation of a hexagonal structure
2056 (MHexagonalFT)
2057
2058 - added class to perform fourier tranformation of a hexagonal structure
2059 in a tasklist (MHexagonalFTCalc) example: hft.C
2060
2061 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2062 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2063 small pixels, example: extendcam.C
2064
2065 - added possibility to write data to memory (TTree) using MWriteRootFile
2066
2067 - added possibility to read a TTree stored only in memory by MReadTree
2068
2069 - new classes to deal with the interleaved calibration events:
2070 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2071
2072 - implemented filters to callisto to skip calibration events
2073
2074 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2075 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2076 the slices by statistics
2077 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2078 signal extractor without randomization
2079 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2080 with the signal extractor with randomization (extraction window is
2081 randomly fixed)
2082 The three kind of pedestal is not yet implemented (for speed reasons) as
2083 long as nobody really needs it:
2084 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2085 extracted with the signal extractor with randomization
2086
2087 - callisto now finds the pulse position in the data automatically
2088
2089 - implemented data reduction in calibrated data by reducing the precision
2090 of the stored floating point values (pedestal, rms and signal) to
2091 roughly 0.5%
2092
2093 - fixed showplot to make file format conversion (eg. converting a
2094 status display stored in a root file into a postscript file) in
2095 batch mode possible:
2096 showplot -b --save-as-ps[=outfile.ps] infile.root
2097
2098 - Allow class names as part of filter rules, eg
2099 (MFSupercuts) && (MHillas.fSize>100)
2100
2101 - fixed a lot of stuff to allow all programs to process MonteCarlo
2102 camera files.
2103
2104 - enhanced possibility to debug reading of resource file
2105
2106 - MDataChain should handle priorities of operator more
2107 accurate now
2108
2109 - completely revised the container in which the signal is stored
2110 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2111 * the new implementation is faster and
2112 * needs less storage space
2113
2114 - FIRST version which can process Monte Carlos through the
2115 whole chain of programs (callisto, star, etc)
2116
2117 - implemented new image parameters for the border length of
2118 the shower image (MNewImagePar2)
2119
2120 - implemented wobble-mode in ganymed
2121
2122 - new class (MJOptimize) taking care of all optimization processes
2123
2124
2125
2126 *** Version 0.8.6 (2004/10/05)
2127
2128 - New combined signal and time extractor
2129 MExtractTimeAndChargeDigitalFilter
2130
2131 - The Report for the trigger section in the CC run summary has been
2132 updated, and now the IPRs (Individual Pixel Rates) are available.
2133
2134 - new macros for database interaction: filldotrun.C, filldotrbk.C
2135
2136 - added new program which can convert colored output which was redirected
2137 into a file back into colored text (for example to display it with
2138 more): showlog
2139
2140 - added new program to display an MStatusArray of plots (stored with
2141 MStatusDisplay) from a file: showplot
2142
2143 - Added support for Sequences (MSequence). Sequences are blocks of run
2144 files containing the same calibration and belonging to the same
2145 source
2146
2147 - Added a new task (MTaskEnv) which can be used in setup files to switch
2148 between different tasks (for example to choose a signal extractor)
2149
2150 - Implemented automatic file splitting in MWriteRootFile
2151
2152 - After image cleaning an island index is assigned to all used pixels.
2153 The index corresponds to the order of the islands in size.
2154
2155 - added a cleaning which takes signal height _and_ arrival time into
2156 account: probability cleaning (for more details see MImgCleanStd)
2157
2158 - added a cleaning which takes takes the absolute number of photons
2159 times the area ratio as cleaning level
2160 (for more details see MImgCleanStd)
2161
2162 - Changed calculation of image parameters such, that it can be done
2163 for all used pixels or the pixels with a defined island index only
2164
2165 - implemented new image parameters displaying the number of islands,
2166 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2167
2168 - event display in executable changed to support also calibrated files
2169 (done with MJCalibrateSignal)
2170
2171 - added program doing the calibration and the signal extraction
2172 and signal calibration: callisto Most part of the setup is done
2173 by a resource file: callisto.rc
2174
2175 - implemented support for pixels with negative IDs (Raw file format
2176 version 4)
2177
2178 - implemented an new option in merpp (--auto-time) to get the time
2179 range for cc and/or caco data from the run header of the raw data
2180
2181 - New star-program (star and MJStar). Taking calibrated data from
2182 callisto/MJCalibrateSignal as input. The setup is done through
2183 a resource file: star.rc
2184
2185 - Added possibility to setup the eventloop in the mars-executable
2186 Camera Display by a resource file: mars.rc
2187
2188 - The the mars-executable Camera Display can now also read
2189 calibrated data files written by callisto/MJCalibrateSignal
2190
2191 - Added a new class which can calculate the source position in
2192 the camera from a pointing model known to be correct and
2193 the pointing model used for observations (MSrcPosFromModel)
2194
2195 - added a new version of the class calculating the effective on-time
2196 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2197 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2198 MHTimeDiffTheta.
2199
2200 - added the possibility to count how often a signal is above (or
2201 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2202 can replace MHTriggerLvl0)
2203
2204 - added ore convinient ways to set the axis-titles of your histograms
2205 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2206 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2207
2208
2209
2210 *** Version 0.8.5 (2004/08/06)
2211
2212 - new Signal Extractors: MExtractFixedWindowSpline
2213 and MExtractAmplitudeSpline
2214
2215 - implementes interleave in merpp to be able to merpp parts of a file
2216
2217 - implemented force-functionality to merpp
2218
2219 - star display to display star catalogs (MAstroCatalog)
2220
2221 - star display to 'mirror' stars to the camera (MAstroCamera)
2222
2223 - implemented a new cleaning option which allows cleaning scaled with
2224 the real ratio of the rms depending on the pixel size, not only the
2225 square root of the pixelsize (MImgCleanStd, MCameraData)
2226
2227 - removed obsolete MBlind* classes
2228
2229 - Signal extractor taking the AB flag into account implemented (this makes
2230 an odd number of slices for signal extraction possible
2231 (MExtractSignalABcorr)
2232
2233 - implemented a class extracting the pedestal from the raw-data (events)
2234 itself using empty lo-gain (MpedCalcFromLoGain)
2235
2236 - Added mean values to MPedPhotCam
2237
2238 - Added Makefile for Darwin (this OS is NOT officially supported!)
2239
2240
2241
2242 *** Version 0.8.4 (2004/04/19)
2243
2244 - new fast arrival time extractor using cubic splines:
2245 MExtractTimeFastSpline
2246
2247 - implementes multi-argument support in MDataChain
2248 ("pow(a, b)")
2249
2250 - implemented double reference support in MDataChain
2251 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2252
2253 - added support in MF for expressiond like
2254 "MHillas.fWidth<2*<MHillas.fLength"
2255
2256 - MDataChain is now able to support variables like [0], [1], ...
2257 which can be used in fit functions as parameters. The interface
2258 is implemented through the new virtual function
2259 MParContainer::SetVariables
2260
2261 - added new class MArrivalTimeCam/MArrivalTimePix:
2262 Storage containers to hold the ArrivalTime of the camera/pixel
2263
2264 - added new classes for the calibration of relative arrival times:
2265 MCalibrationRelTimePix and MCalibrationRelTimeCam
2266
2267 - added new classes to extract the signal of the blind pixel and the
2268 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2269
2270 - added new classes for the bad-pixels treatment (MBadPixels*)
2271 which are more powerfull than the old ones (MBlindPixel*)
2272 and will replace them.
2273
2274 - added filter against cosmics: MFCosmics
2275
2276 - added new class MArrivalTimeCalc2:
2277 Calculates the arrival time as the signal weighted mean of the time
2278 slices in the maximum window
2279
2280 - added a new macro call pointspreadfucntion.C that fits with a 2D
2281 gaussian the DC spot for an star. It gives you the RMS of
2282 the PSF and the center of the star, very useful for misspointing
2283 studies.
2284
2285 - added support for multi-telescope camera files. Added classes
2286 MStereoCalc and MStereoPar, classes to calculate and store shower
2287 parameters calculated from the data of two telescopes, for the MC
2288 studies regarding the MAGIC clone.
2289
2290 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2291 MC data calibrated in photons instead of ADC counts.
2292
2293 - added three macros to show the calibration and analysis chain of
2294 MC data. The macro starmc.C does both calibration and analysis, producing
2295 an output containing Hillas parameters for each event. The macro
2296 mccalibrate.C does just the calibration and writes out a file containing
2297 pixel information in photons instead of FADC data. The macro starmc2.C
2298 reads in such a file and produces an output with Hillas parameters.
2299
2300 - added MPedPhotCalc to compute pedestals in units of photons, see
2301 macro pedphotcalc.C
2302
2303 - added all class to perform the calibration, see macro calibration.C
2304
2305 - added class MFFT to perform Fast Fourier Transforms
2306
2307 - added class MSimulatedAnnealing to perform simulated annealing
2308 minimizations
2309
2310 - added new macro bootcampstandardanalysis.C which holds the skeleton
2311 of the analysis chain discussed in the december bootcamp.
2312
2313 - added support for DAQ raw data file format V2
2314
2315 - implemented an arbitrary time stamp for the events from raw-data
2316 files with file version<3. It is calculated from the run number,
2317 the date of start and the FADC clock tick from the first module
2318
2319 - implemented the correct decoding of the event time-stamp
2320 coming from the DAQ for raw-data files with file-version>2
2321
2322 - added a new classes storing the pedestals in units of photons:
2323 MPedPhotPix, MPedPhotCam
2324
2325 - added support for DC current files from the camera control
2326
2327 - added support for start- and stop-time when merpping report files
2328
2329 - added MReportCC storing the weather data from the CC-REPORT
2330
2331 - added class to fill trainings and test matrices (MTFillMatrix)
2332
2333 - added a filter performing a software trigger (MFSoftwareTrigger)
2334
2335 - Added classes to perform parts of the standard analysis (Jobs):
2336 + MJPedestals
2337 + MJCalibration
2338 + MJExtractSignal
2339 Note: All of them are preliminary!
2340
2341 - Added Iterator to iterate over files giving only the run-number
2342
2343 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2344 the evolution of a sector vs time
2345
2346
2347
2348 *** Version 0.8.3 (2003/12/05)
2349
2350 - adapted Random Forest classes to allow the use with MC
2351 multi-telescope files which can be produced with the coming
2352 camera version 0.7.
2353
2354 - added classes to read and interprete central control report files
2355 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2356
2357 - enhanced merpp (the executable) to support .raw and .rep files.
2358
2359 - added classes for light calibration (MCalibration* and
2360 MHCalibration*) by Markus Gaug. Further work has to be and will
2361 be done soon.
2362
2363 - Added a preliminary 'synchronizer' (MReadReports) which will
2364 replace MReadMarsFile as soon as it is finished.
2365
2366 - Added a tutorial macro demonstrating how report files are merpped
2367 and how they can be read from the root file in the correct order
2368 of time (readrep.C)
2369
2370 - Added a generalized histogram (similar to MH3) called MVsTime
2371 which allows to plot variables (or rules - MDataChain - of
2372 variables) vs time. For an example have a look at tempvstime.C.
2373
2374 - Changed the name of the event trees:
2375 + Events --> Events
2376 + PedEvents --> Pedestals
2377 + CalEvents --> Calibration
2378
2379 - changed name of MTime in the event trees from MRawEvtTime to MTime
2380
2381 - added displaying the sector indices to the mars event display
2382
2383 - Magic Online Analysis (MOnA) implemented in a first version
2384 (see mona.cc, MOnlineDump and MOnlineDisplay)
2385
2386 - added classes to calculate event rate
2387 (preliminary: MEventRateCalc, MEventRate)
2388
2389 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2390
2391 - added classes dealing with the telescope pointing position (MPointing*)
2392
2393 - implemented the 'final' Mars time stamp based on some experiences with
2394 the new 'Synchonizer'
2395
2396
2397
2398 *** Version 0.8.2 (2003/11/10)
2399
2400 - accelerated standard analysis by a factor of 6-8 ...
2401 + doing precalculations in MGeomCam for the pixel area ratio
2402 + creating a look up table for the single pixels in MCerPhotEvt
2403
2404 - added task to calculates weights in case you want to 'change'
2405 the energy spectrum of a monte carlo file
2406 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2407
2408 - added a new executable star which implements the
2409 star.C macro as precompiled executable. Currently a flexible
2410 setup is not possible, but a 'input card' setup will follow.
2411
2412 - Starting to implement Multi-Telescope-Support based on the
2413 upcomming camera version 0.7. The base for a general support
2414 is implemented and the star-functionality is proven to work.
2415
2416 - Replaced Event-Display in and Camera-Display in the Mars GUI
2417 executable by a more convinient display base on MStatusDisplay.
2418
2419 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2420
2421
2422
2423 *** Version 0.8.1 (2003/10/20)
2424
2425 - added signal subtraction for pure on data by means of fitting
2426 the background in the off region or by performing a combined
2427 signal/background fit. Provides necessary histograms for
2428 obtaining energy spectra and a light curve.
2429
2430 - added classes to perform and study the selection of the
2431 2nd Level Trigger on MC data (example in triglvl2.C macro)
2432
2433 - added pedestal calculation
2434
2435 - implemented "democratic cleaning" (tail cut value proportional
2436 to pixel area) according to Wolfgang's suggestion.
2437
2438 - added Sigmabar treatment (calculation and basic histogramming)
2439
2440 - added basic routines to apply padding
2441
2442 - added first implementation of MARS-based source visibility plotter
2443 (needs to be linked against slalib, preliminary version)
2444
2445 - enhanced functionality of data chains: random numbers, conversion
2446 functions and access to MHMatrix objects
2447
2448 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2449 numbers under certain circumstances (runs with 0 events included)
2450
2451 - fixed a bug in the general filter MF (didn't work on some systems
2452 at all)
2453
2454 - fixed a bug in chaining files, which caused the analysis to crash or
2455 ignore files
2456
2457 - implemented more geometry classes describing the parameters used
2458 to simulate the PMT camera
2459
2460 - added new Monte Carlo classes containing the setup of the different
2461 programs in the MC chain.
2462
2463 - added a (preliminary) general task to evaluate chi-square of a given
2464 parameter in an eventloop.
2465
2466 - first implementation of a container describing the observatory
2467 location (Long, Lat, etc)
2468
2469 - added Random Forest - method for g/h-separation
2470
2471 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2472 (this means, that it is compiling, but not yet fully tested)
2473
2474 - added a new status display which can show the present status
2475 of histograms while an eventloop is running (MStatusDisplay,
2476 an example can be found at status.C)
2477
2478 - reorganized directories:
2479 classes describing the image --> mimage
2480 classes containing Monte Carlo Histograms --> mhistmc
2481 classes for Random Forest method --> mranforest
2482
2483 - added (event-)weights to fill histograms
2484
2485 - colors in logging output to screen
2486
2487 - changes to the Image Parameter declaration:
2488 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2489 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2490 + MHillasExt now derives from MParContainer instead of MHillas
2491 --> Files written with the old definition are more or less unreadable
2492
2493 - reading of reflector files
2494
2495 - display data from reflector files in the camera
2496
2497 - implemented currents (and display them in the camera)
2498
2499 - logarithmic scale in camera
2500
2501 - added class to iterate through directory contents (MDirIter)
2502
2503
2504
2505 *** Version 0.8 (2002/11/18)
2506
2507 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2508
2509 - corrected 48(!) wrong entries in the Next Neighbor table of the
2510 Magic Camera (all in the inner part of the outer ring, mostly
2511 missing a single NN)
2512
2513 - Fixed a bug in the table describing the Next Neighbours of the
2514 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2515 have any neighbour)
2516
2517 - changed trigrate.C: now it calculates the pure NSB triggers from
2518 a camera file (generated with no showers), so there is no need
2519 to introduce them by hand in the BgR array (for more details
2520 please ask Abelardo)
2521
2522 - added MHHadronness (and MHadronness) as a general facility to evaluate
2523 the quality of a gamma-hadron seperation method
2524
2525 - changed MWriteAsciiFile to accept rules (MDataChain)
2526
2527 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2528 must be replaced by calles to MWriteAsciiFile::AddColumn and
2529 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2530 changed.
2531
2532 - Implemented generalized event-matrices (one row per event)
2533 (MHMatrix)
2534
2535 - implemented the one dimensional composite probabilities
2536 (MHCompProb, MCompProbCalc, comprob.C)
2537
2538 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2539 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2540
2541 - Added a camera display displaying the pixel numbers to the
2542 event display gui.
2543
2544 - Added Monte Carlo Informations to event display gui
2545
2546 - Changed the camera display to display the pixel numbering
2547
2548 - Added three buttons to the camera display to change the palette
2549
2550 - Added the number of used and core pixels after image cleaning
2551 to MHillas
2552
2553 - Changed the algorithm used in MHillas according to TDAS 02-03
2554
2555 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2556
2557 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2558
2559 - Added fCosDeltaAlpha to MHillasSrc
2560
2561 - The numbers of photons used to calculate fConc and fConc1 in
2562 MHillasExt are now scaled with the pixel size, so that one get
2563 a four times smaller value for the bigger pixels in the outer ring.
2564
2565 - added new task to smooth the camera contents (MCameraSmooth)
2566
2567 - added possibility to use interpolated pixel values for blind pixels
2568 instead of removing it completely from the analysis
2569
2570 - Implemented the possibility to save the whole eventloop with
2571 its setup to a file. This information can be read and from
2572 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2573 and MEvtLoop::MakeMacro. If you find something not working, please
2574 report - this stuff is still in a beta phase.
2575
2576 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2577 file having crab starfield, but also for all following files - fixed
2578
2579 - MTaskList::PrintStatistics can now be instructud to print also the
2580 title, too: use PrintStatistics(0, kTRUE)
2581
2582 - Changed the image cleaning so that pixels with to many 'used'
2583 neighbors are left used (to get rid of 'holes' in events)
2584
2585 - Introduced more output to the camera displays
2586
2587 - Added an array of histograms (eg one hist per run), MHArray
2588
2589 - Added a _preliminary_ version of the reader for CT1 PreProc files
2590 (MCT1ReadPreProc)
2591
2592 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2593 (thanks to Raquel)
2594
2595 - added the first energy estimator (MEnergyEstParam, estimate.C,
2596 estfit.C) using a parametrization
2597
2598 - Added some new Monte Carlo paremeter containers used to store
2599 setup information from the MC chain (MMcConfigRunHeader,
2600 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2601
2602
2603
2604 *** Version 0.7 (2002/04/30)
2605
2606 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2607 the pedestal mean value was saved incorrectly. For files from
2608 this versions we substract 0.5 from the pedestal mean.
2609 WARNING: This may effect your results, so don't wonder...
2610
2611 - First implementation of an algorithm using only triggered events
2612 for the collection area calculation
2613
2614 - Ascii Output can now also be used for parameter containers which
2615 doesn't overload MParCointainer::AsciiWrite
2616
2617 - The Ascii Output is now also capable of writing single data members
2618 of one container
2619
2620 - You are now able to change the order of the values written to the
2621 ascii file
2622
2623 - You can now specify a conversion factor for each data member written
2624 to an ascii file. This may be usefull to change the units of the
2625 data member (eg. degrees instead of millimeters in case of the
2626 hillas parameters)
2627
2628 - Replaced old MHillas by a new structure which allows you to extend
2629 the parameters stored in MHillas very easily:
2630 see MHillas and MHillasExt
2631
2632 - Added classes to handle source dependancy of image parameters:
2633 see MHillasSrc
2634
2635 - Added container (MBinning) to have a standard input for the binning
2636 in different histograms (eg. the Energy bins should be the same in
2637 all histograms)
2638
2639 - Changed Hillas histograms from mm to deg
2640
2641 - Added the flexible binning to the hillas histograms
2642
2643 - Added a filter for the alpha parameter (MFAlpha)
2644
2645 - It is now possible to write single data members of a class object to
2646 an output stream instead of the whole container only
2647
2648 - Added a generalized filter for a data member:
2649 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2650
2651 - Added a generalized Filter parser for more difficult filter rules
2652 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2653
2654 - Added new Monte Carlo histograms:
2655 MHMcEnergyImpact and MHMcEfficiency
2656
2657 - Added many new histograms needed for the flux calculation.
2658
2659 - Added a generalized histograms which can fill and show up to three
2660 data members in either a one-, two- or three-dimensional histogram, eg:
2661 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2662
2663 - Added:
2664 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2665 * calculation of <Theta> as a function of time (MHThetabarTime)
2666 they are needed in the flux calculation in
2667 order to select for a given bin in Theta (or time) the appropriate
2668 effective collection area, which is assumed to be given as a function
2669 of Theta and the true energy
2670
2671 - Added calculation of the migration matrix in the energy
2672 (MHMcEnergyMigration):
2673 the migration matrix describes the migration from the true (E_true)
2674 to the estimated energy (E_est); it is needed to determine the
2675 distribution of E_true from the measured distribution of E_est
2676 by unfolding
2677
2678 - changed the color palette in the camera display to DeapSea.
2679
2680
2681
2682 *** Version 0.6 (2002/01/15)
2683
2684 - Introduce the option of disable pixels (MBlindPixels and
2685 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2686 able to deal with Star Field NSB.
2687
2688 - Fixed a bug in the pedestals substraction
2689
2690 - Introduced verbosity levels
2691
2692 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2693
2694 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2695 work correctly (thanks to Abelardo)
2696
2697 - Introduced correct treatment of the diffuse Night Sky Background
2698 and NSB (MMcPedestalNSB)
2699
2700 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2701
2702 - Introduced MMcRunHeaders which contains monte carlo run informations
2703
2704 - Added a 'Print'-Task (MPrint) which calls the Print function
2705 of a parameter container for each event
2706
2707 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2708
2709 - changes to be more efficient with root 3.02/06
2710
2711 - root 3.02/06 fixes:
2712 + the memory leak when reading MRawEvtData
2713 + loosing more time than necessary to update the progress bar
2714
2715 - MWriteAsciiFile is now capable of writing more than one container
2716 in a line. For example: To be able to write Monte Carlo and
2717 Hillas values (energy and alpha) in one line.
2718
2719
2720
2721 *** Version 0.5 (2001/11/06)
2722
2723 - Added new GUI functionality (Analysis)
2724
2725 - Added a camera display to be able to display events in the camera
2726 together with the calculated hillas ellipse
2727
2728 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2729 object at any state of the analysis, so that the output are several
2730 states
2731
2732 - Fixed a bug in the collection area error calculation
2733 (Thanks to Ciro and Abelardo)
2734
2735 - Fixed a bug which causes merpp to crash in some environments
2736
2737 - Implemented auto enabling scheme for Branches to speed up reading
2738 a lot (see MReadTree and MTask)
2739
2740 - Fixed a bug in the Histogram classes which caused histograms to
2741 be written to a file by MWriteRootFile without request
2742
2743 - changed the object I/O from the old stylish root I/O to the new
2744 'auto evolution scheme' This was done only for classes which are not
2745 yet used in Monte Carlo files, so that these files are still readable.
2746
2747 - Added support for a progress bar in MEvtLoop and MReadTree
2748 (see the Analysis Window in Mars for an example)
2749
2750 - Fixed a bug in the package creation which disturbed the conversion
2751 between a mars version unpacked from a tar file and the repository.
2752
2753 - Changed the code to writer merpped (converted into root format)
2754 raw files, to get faster (around 10%)
2755
2756
2757
2758 *** Version 0.4 (2001/09/20)
2759
2760 - This release is made to compile on a root version >= 3.00
2761
2762 - Fixed a bug which causes MReadTree to read the first file only
2763
2764 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2765
2766 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2767
2768 - Added a task to write several container to a root file (MWriteRootFile)
2769
2770 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2771
2772 - Added calculation of the collection area (MMcCollectionAreaCalc)
2773
2774 - fixed some bugs in the Hillas calculation
2775
2776 - added filters to be able to control the task execution dependent on
2777 a parameter (for example: the number of level 1 triggers in a MC-file)
2778
2779
2780
2781 *** Version 0.3 (2001/04/23)
2782
2783 - Many demo macros added
2784
2785 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2786
2787 - Hillas Calculation added
2788
2789 - Standard image cleaning available
2790
2791 - MReadTree is now able to handle more than one file
2792 (Remark: of the same structure)
2793
2794 - Now we are able to display events in a first version of the
2795 Camera event display. To do this we must run the macro
2796 "macros/readCT1.C" to read data from CT1.
2797
2798
2799
2800 *** Version 0.2 (2001/01/24)
2801
2802 - First Implementation of a Gui to read the raw data. Start the
2803 gui with the command mars.
2804
2805
2806
2807 *** Version 0.1 (2000/12/20)
2808
2809 - First official release 0.1
2810
2811 - Changes:
2812
2813 + changed calling style of MRawPixelIterator from do...while to
2814 while-loop