source: trunk/MagicSoft/Mars/NEWS@ 8933

Last change on this file since 8933 was 8933, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 116.4 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;Database
6
7 * introduced average temperature and wind speed from star-files
8
9 * introduced the ratio of accepted calibration events in the
10 calibration run
11
12 * introduced the average rates of the different trigger pattern,
13 e.g. the rate of pedestal and calibration events, from the signal-file
14
15 ;general
16
17 * fixed GroupBy options in plot*.C macros
18
19 * only display KVA points (not the Tuorla points) in plotoptical.C
20
21 * all programs now allow to add resources to the ones from the resource
22 file or overwrite them from the command line. This can be done like this
23 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
24 if something seems to be wrong you can debug what the program is doing
25 using the option --debug-env=3
26
27 * increased the diversity of debug levels. That also means that with -v3
28 you get now less output, i.e. only the output which is important for
29 an analysis. To get more output which helps for debugging try 4, 5 and 6.
30
31 * fixed a problem in the task synchronizing the reading of the reports
32 and the data stream. The effect was that in some circumstances the last
33 events of some trees could have been skipped. Since this is only a
34 very tiny part of the data no severe effect to your analysis results
35 is expected (an exception might be very short, i.e. singel runs,
36 datasets).
37
38 * Dataset file now allow to include the sequence file directly within
39 the dataset file and also allow to exclude single runs from the dataset.
40 (for more details see Class reference of MDataSet)
41
42 * Sequence files now allow for excluding runs from the analysis
43 (for more details see Class reference of MSequence)
44
45 * added code to process the sum-trigger flag
46
47 * the histogram classes MH3 and MHn now support profile histograms
48
49 * the histogram classes MH3 and MHn now support labels at the axis
50
51 * the Random Forest Train-classes (MJTRain*) now store the used datasets
52 in the output file
53
54 * the MFMagicCuts have a new option to allow a linear area cut (for
55 special studies)
56
57 * The liniking of the shared object is now done into a file defined
58 by 'mktemp'. This should be a local file system which accelerates
59 liniking a lot.
60
61 * The code has been prepared for compilation with root 5.18/00d
62
63 ;merpp
64
65 * Implemented cc file version 2008-20-02/0
66
67 * Added Pyroemeter information to output (stored in a new Tree
68 Pyrometer, needs a complete new merpp, i.e. new calibration)
69
70 ;callisto
71
72 * in the pedestal processing now at least 50 processed events are
73 required for succeeding.
74
75 * the signal and calib files now contain also the sequence information
76
77 * the two MPedestalCam in the calib file now have proper names
78 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
79
80 * Both pedestal cams now conatain the number of events processed
81
82 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
83 i.e. for the extraction of the calibration pulses basically the average
84 over all events of the first slice instead of all slices was used.
85 Since pedestal and calibration constants are continously recalculated
86 this only effected the very first events of every sequence.
87
88 * For the extraction of the position of the maximum sample now the
89 extraction range is set automatically to the extraction window,
90 before the whole accessible range was used.
91
92 * If the number of samples in the events and the number of samples
93 in the run-header disagrees now an error is raised (this can
94 happen in not well simulated Monte Carlo files)
95
96 * In the case of MUX-data pedestal events with the lvl1 trigger flag
97 could survive into the pedestal calculation -- fixed.
98
99 * Tab "TrigPat" added showing the distribution of the trigger pattern
100 as found in the run-files (normalized with the run length)
101
102 * The selection of events from the trigger pattern has been improved.
103 If the trigger pattern is corrupted events won't pass anymore.
104
105 * Added a new command line option --dev-null to suppress output of
106 Y-files (this is useful for test cases)
107
108 ;star
109
110 * the star file now contains also the sequence information
111
112 * Added a new command line option --dev-null to suppress output of
113 I-files (this is useful for test cases)
114
115 * Tab "Rate" added showing the distribution of the trigger pattern
116 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
117 the Y-files (normalized with the run length)
118
119 * The effective on-time calculation doesn't use events with only
120 sum-trigger anymore
121
122 ;ganymed/sponde
123
124 * Now data points are even shown correctly if they have error bars larger
125 than one sigma. Points with null or negative significances are omitted.
126
127 * DrawNicePlot now allows to set a projection range
128
129 ;sponde
130
131 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
132
133 * a new option "--force-runtime" is available. In case of very short
134 datasets (for light-curves) which are in the order of a few
135 minutes the calculated effective on-time is not very acurate because
136 it is quantizised in th eorder of a minute. Therefore you can switch
137 to using the real run-time instead (remakrt: this ignores any
138 dead-time!)
139
140 * a more analytical way is used to "fill" Monte Carlos into regions
141 of impact parameters which have not been simulated because the
142 trigger efficiency is assumed to be 0.
143
144 * estimated sensitivity curves for hi and lo zenith angles are shown
145 scaled to the correct observation time and collection area
146
147 * the Monte Carlo events after cuts are now written to the output file
148 if an output file given
149
150
151
152 *** Version 2.0 (2007/09/03)
153
154 - database: the position used for the pulse pos check was missing
155 in the callisto output and could thus not be filled into the DB.
156 Also the old values seemed not exactly the PulsePos used for
157 teh check.
158
159 - general: Resource file now allow an Include-Resource, i.e. you can
160 read a resource file with default settings, include it in your
161 resource file and overwrite the settings in your file. More than
162 one include file is allowed. Inclusions can be iterative.
163 Include: mydefaults.rc yourdefaults.rc
164 The resources in the first file have higher priority than the
165 second file.
166
167 - general: Now the output files (calib*.root, etc) also contain the
168 resource file (to check it open it in the TBrowser and choose Print()
169 from the context menu)
170
171 - general: Dataset files now allow to overwrite the default path
172 to search for sequence and data files. Note, that the program
173 option and individual resources will overwrite it. For example:
174 SequencePath: /magic/montecarlo/sequences
175 DataPath: /magic/montecarlo/star
176
177 - general: Fixed a problem with variables in MDataPhrase. It seems
178 that only optimdisp (didn't work) was effected.
179
180 - general: Some improvements to the optim and train processing. For
181 example the ststud window now got a proper title.
182
183 - general: The "Status Display: " was removed from the window title
184 within an Eventloop.
185
186 - general: added a new flexible histogram-class (MHn) which can be used
187 for example in testing after optimizations or training to produce
188 user defined histograms.
189
190 - general: The Random Forest now allows attaching an evaluation
191 function which is applied to its output. This allows to train
192 on whatever you like (eg. train on log10(energy), but return
193 energy)
194
195 - general: The Random Forest training of energy (trainenergy.c) and
196 disp (traindisp.C) has been improved by more graphical output to
197 judge the result.
198
199 - general: The training of energy (trainenergy.C) has been improved
200 a lot by training on a different quantity than energy. It gives
201 a result which is highly independant of the source spectrum
202 and shows lower bias than all other options.
203
204 - general: Dataset files are allowed to contain collections of
205 datasets. For more details see the class reference of MDataSet.
206
207 - general: The default WobbleMode in a datset file now (if not
208 overwritten) is "auto", i.e. wobble mode is set if the dataset
209 doesn't contain off-sequences.
210
211 - merpp: Merpp can read file format version 9 now. Please realize
212 that for file format version 9 the extraction range is different
213 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
214 the first and last 15 slices have been removed from all MUX data.
215
216 - mars: Similar to writing movies you can now select events which
217 should be displayed in your display. Therefore add the following
218 lines to your mars.rc:
219 MFEvtNumber.FileName: ganymed00223552.root
220 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
221 The input file can be a ganymed-file after (ganymed*.root) or
222 before (ganymed*-summary.root) file. For example to select all events
223 from your on sample after cuts (excluding the ThetaSq cut) use
224 MFEvtNumber.Selector: DataType.fVal>0.5
225 To show all events from your on-sample after quality cuts
226 use the summary file instead.
227
228 - mars: new ways to call mars are implemented. Instead
229 of calling
230 mars filename.root
231 you can now also use
232 mars sequence.txt
233 or
234 mars sequence.txt inputpath
235 or replace sequence.txt by the sequence number if the default
236 sequence file should be used.
237
238 - mars: The default size has been increased
239
240 - mars: There are two new heckboxes which allow to switch off
241 the calculated image parameters
242
243 - callisto: was broken for MCs... fixed.
244
245 - callisto: improved calculation of spline coefficients a lot. This
246 leads to a further improvement of the event rate calibrating MUX
247 data of about 15% (175evt/s instead of 150evt/s)
248
249 - callisto: finally the raw data we read is now real 16bit (with
250 10bit precision) for MUX data and not a stripped 8bit number
251 anymore. Due to scaling of the numbers (without precision loss
252 into an [0-256[ range, the final numbers for pedestal, pedestalrms
253 and extacted signal don't change. However, at all places where
254 raw data is directly accessed (eg. saturation and variation
255 limits in the signal- and pedestal-extraction) the numbers
256 refer still to the data's 16bit range.
257
258 - callisto: The maximum arrival time difference used in the bad
259 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
260 for both, old FADC and MUX-FADC, data.
261
262 - callisto: Be aware that callisto is now calibrating the arrival time
263 in nanoseconds rather than time slices. Also all following tasks
264 have been changed to assume ns units now. If you star data
265 calibrated with an older version it might be necessary to adapt
266 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
267 to obtain optimal results. The plot in the PulsePos tab
268 will now be in ns, too. This might also mean that the Muon
269 analysis in star might not work as perfect as expected as long
270 as old files read in.
271
272 - callisto: The calibration constants of earlier updates got lost
273 somehow. All constants have been updated.
274
275 - star: The PSF is now determined from the profile of the ArcWidth
276 instead of arcwidth/radius. The old way gave to much weight
277 to the bins with low statistics. The reference lines have been
278 updated.
279
280 - star: For speed reasons events suitable for the muon analysis
281 are now also preselected by fConcCOG<0.1 which seems to be a very
282 good preselector for muons.
283
284 - star: is now calculating a new timing parameter the Slope along
285 the major and minor axis of the shower. Therefore a numerical
286 solution of a line-fit is used. To use MHillasExt.fSlopeLong
287 and MHillasExt.fSlopeTrans don't forget to multiply it with
288 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
289
290 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
291 have been removed from MNewImagePar. They have never been good for
292 anything.
293
294 - star: Implemented a new recursive algorithm which is supposed to be
295 faster. Also implemented new cleaning oiptions, which are:
296 + CleanLevel0:
297 The cleaning level above single core pixels can be kept
298 + KeepIsolatedPixels:
299 Define whether single core pixels should be kept
300 + TimeLevel1:
301 The coincidence window in nanoseconds to single used neighbors
302 + TimeLevel2:
303 The coincidence window in nanoseconds to two used neighbors
304 + PostCleanType:
305 MOde in which a time dependent post cleaning should be applied
306 0: No post cleaning
307 1: Require for each used pixels at least one used neighbor
308 within a time-window of CleanLevel1
309 2: Require for each used pixels at least two used neighbor
310 within a time-window of CleanLevel2
311 3: Require first two and second one used neighbor
312 within a time-window of CleanLevel1 and fCleanLevel2
313 respectively
314 + RecoverIsolatedPixels:
315 - recoveres isolated core pixels if they have a used neighbor
316
317 - mars/star: The new default cleaning is:
318 + CleanLevel1: 6.0
319 + CleanLevel2: 3.0
320 + CleanTime1: 1.75
321 + CleanTime2: 1.75
322 + PostCleanType: 3
323
324 - star/ganymed: The old spark-cuts have been replaced by new ones.
325 These new spark cuts have been cross checked with the sequences
326 84720 (before splitter), 101041 (after splitter) and 223539 (new
327 FADCs). In all cases they seperate pretty well, but of course not
328 perfect. Monte Carlos have suggested to tighten the cuts a little
329 bit further at low sizes. This has been done.
330
331 - ganymed: IMPORTANT - The spark cuts have been changed to match
332 all available data more or less well. This might mean that for
333 YOUR data there are still sparks visible.
334 Whenever you do an analysis you have to make sure that NO sparks
335 survive your cuts!
336
337 - ganymed: The old hadronness and size cuts have gotten new indices
338 (10, 11). The old indices 8 and 9 now mean an additional condition
339 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
340 If you want to switch off this cut just move the line far away enough,
341 e.g. by setting c[9] to -500. Please update your ganymed.rc files
342 accordingly!
343 The unit of c[9] is deg. It is the dist at which your cut will
344 cross the slope==0. The unit of the slope is ns/deg. So if
345 you readin files calibrated with an older Mars-version you
346 have to adapt the default value for c[9] to the FADCs:
347 - Multiply by two for the MUX FADCs (run number > 200.000)
348 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
349 - Multiply by 42 for the meaning of life (run number = 200.000)
350
351 - ganymed: The old Cut0 is now called CutQ and is calculated before
352 the source position is caluclated. If you need a quality cut
353 including source dependant data (be very carefull with this!)
354 you have to use Cut0 instead.
355
356 - ganymed: now properly supports three off regions in wobble mode.
357 It will be the default from now on in ganymed_wobble.rc. To change
358 the number of off-regions use
359 NumOffSourcePositions: 1
360 in your ganymed.rc. Also by default no off-theta cut will be done
361 anymore so that you will get a background level higher than the
362 signal level in your ThetaSq plot for ThetaSq>0.2.
363 Due to this be carefull changing the scaling mode away from
364 "None". You will underestimate your signal if your scale interval
365 is not properly set.
366 (Rem: ThetaSqN is no longer needed)
367
368 - ganymed: is now storing the events of all (on- and off-)
369 source positions even in the case of more than one off-source
370 position. This should allow sponde to work properly and the
371 energy estimation is done correctly in all cases (without any
372 "nearest position" trick)
373
374 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
375 with a real pointing model for the starguider is done, calibrated
376 with more than thousand tpoints taken from this date on.
377
378 - ganymed: was broken for Wobble-MCs... fixed.
379
380 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
381 has changed. Note that your old ganymed.rc will be incompatible
382 with the new algorithms! Please check the ganymed.rc files and
383 the class description of MFMagicCuts for more information.
384 It is recommended at the moment to use identical Disp-Parametrizations
385 for on/off- and wobble-mode. If cuts are optimized only
386 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
387 should be optimized. All other values should be kept as they are.
388 If you want to do an anylsis without timing a parameters, you can
389 switch off the timing cuts by seeting parameter 7 to a very small
390 value (eg. -99). To remove the slope parameter from the disp
391 paremtrization set parameter 8 to 0.
392
393 - ganymed: The distribution of observation time versus zenith
394 angle is now shown for off- AND on-data.
395
396 - ganymed: The contents of the source position plot are no longer
397 averaged, thus a lot of (fake) events between the two wobble
398 positions have disappeared.
399
400 - ganymed: There is a new tab "CutT" it contains the VsSize plots
401 with the CutT, whihc is defined in ganymed.rc, applied. It
402 is resonable to use your theta-cut for it, to see if there is
403 something strange (sparks!) in your signal-region.
404
405 - ganymed: To choose a dataset from a collection in a dataset file
406 use the new command line option "--dataset=12345"
407
408 - optim, sponde: should now properly support three off-regions.
409 Just produce your ganymed summary files with three off-regions.
410 optim and sponde will automatically get all off events from
411 all off-regions from this file. Please do not forget to
412 set the scaling in optimwobble.C properly:
413 fit.SetScaleUser(1./3);
414 it is not yet read in automatically (will follow soon).
415 In the case of fixed Scale you can also use
416 cuts.SetThetaCut(MFMagicCuts::kOn);
417 no off-cut needed.
418 Be carefull in case of three off-regions when switching on
419 scale mode. Make sure that the scale interval is set correctly.
420
421 - sponde: sponde.rc and sponde_onoff.rc are now idetical
422
423 - sponde: the resouce files have been rewritten with a lot of
424 comments and a well working parametrization for an energy estimator
425
426 - sponde: In the estimated energy versus monte carlo energy plot the
427 contents where exchanged.... fixed.
428
429 - sponde: the so called "accurate"-mode has been removed. It didn't
430 give any improvement in accuracy, only decreased execution speed.
431
432 - sponde: the so called "simple"-mode has been removed. It didn't
433 give any improvement in simple.
434
435 - sponde: the so called "refill"-mode has been removed. It was anyhow
436 not implemented.
437
438 - sponde: now checks whether the theta distribution of your on-data
439 and the theta-distribution of your Monte Carlo sample (after
440 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
441 sample is incomplete) execution is stopped. Execution can be forced
442 using the new option --force-theta. Use this option with care!
443
444 - sponde: Proper collection areas can now be constructed also from
445 Monte Carlo samples generated with different maximum impact
446 parameters. Note that in previous version you neither got
447 a warning or failure, nor was there any obvious sign that the
448 collection area was overestimated due to usage of files with
449 different maximum impact parameters.
450
451 - sponde: If MC files with different lower energy limits are used
452 the primary MC spectrum is artificially completed down to the
453 lowest energy used at all. WARNING: that this gives correct
454 collection areas ONLY if none of the events in this region would
455 survive your cuts at all.
456
457 - sponde: the output file now contains more information about
458 the spectrum (eg. the full 2D collection area histogram).
459 Note, that this information can only be written to the file
460 if it is stored automatically via command line argument.
461 If you only store the status display from within the display
462 the information is lost.
463
464 - sponde: added a new tab "Disp". It shows the residual of the disp
465 (Disp-Dist) versus several parameters and it is meant to judge the
466 quality of the disp estimator. In the ideal case the residual is zero
467 and doesn't depend on any variable. The tab is displayed after
468 CutQ and Cut0.
469
470 - sponde: added a new tab "Energy". It shows the residual of the
471 energy (lg(estimated energy)-lg(monte carlo energy)) versus
472 several parameters and it is meant to judge the quality of the
473 energy estimator. In the ideal case the residual is zero
474 and doesn't depend on any variable. In reality even a good estimator
475 can show residuals versus Monte Carlo energy. The tab is displayed
476 after all cuts.
477
478 - sponde: added a new tab "EventDist" showing the unweighted real
479 absolute number of events of your sample after cuts. This tells
480 you how many events with this energy you had in your MC files.
481 The same information you get from the error bars of the weighted
482 histograms, but this is less intuitive.
483
484 - sponde: The spectrum plots now show the crab- and 1553-spectrum
485 for comparison. It is not meant to show these curves in
486 publications, they are only for production.
487
488 - sponde: The OriginalMC tree with the events produced by corsika
489 is now processed only once
490
491 - sponde: Finally fixed most annoying bug, which has effected the
492 last bin of the collection area. It was the problem that binnings
493 of root histograms are from 1 to n (included) but there was a C-like
494 loop in sponde from 0 to n (excluded). Now the loop also includes
495 correctly under- and overflow-bins. The worse thing with this is,
496 that for the events in the highest bin not only the bin-content
497 was wrong, but also the weights applied to these events, which could
498 in pricipal effect also other parts of the distribution (eg. due
499 to energy estimation). Fortunately it effected only a few events
500 in most cases.
501
502
503
504 *** Version 1.2 (2007/05/14)
505
506 - database: The database now has two new values Unsuitable50 and
507 Unsuitable01. They express the number of pixels which are
508 unsuitable for more than 50%, respectively more than 1%, of
509 all calibrated event. It is a more accurate number than the
510 previously used numbers, because they only take the first
511 calibration (ignoring the interleaved calibrations) into account.
512
513 - database: The database now has two other new values UnsuitableMax and
514 DeadMax. They express the maximum number of pixels which were
515 unsuitable, respectively dead, during the sequence. Because
516 of high pedestal rms (cars passing) a few events with very high
517 numbers of unsuitable pixels can happen. Not to suffer from this
518 effect we don't take the highest 0.1% of the numbers into account.
519
520 - general: fixed a bug which caused callisto and star to stop working
521 properly because the callisto output was currupted
522
523 - general: a script called scripts/makemovie has been added which
524 simplified the process of producing several movies from a single
525 sequence with different setup.
526
527 - callisto: Some more code cleanup. Started to remove old obsolete
528 code from cvs.
529
530 - callisto: The extraction of the pedestal with the extractor was
531 not random. It seems that extracting at one position is still biased
532 (for example in the first or last slices we could still suffer from
533 switching noise) Now it is completely random.
534
535 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
536 pedestal files) individual pixels could be skipped due to high
537 variations. This was already the case for the pedestal extraction
538 from the lo-gains since the beginning and properly handled
539 there, but was introduced in the extraction from the pedestal files
540 a while ago. To calculate the average value it was still divided
541 by the number of events procesed not by the number of summands
542 really summed. This let to a pedestal which was a tiny amount too
543 small (for a few piels in the order of 0.1%). This led to an slightly
544 positive offset of the randomly extracted pedestal for a few pixels.
545 I doubt that this has a big effect on the result, because the effect
546 on the individual numbers is quite small. Due to this it is suggested
547 that you rerun your calibration to make sure you are without any
548 avoidable bias.
549
550 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
551 the median rms of the absolute arrival time and expressed in significance
552 levels. This replaces the old meaning of an abolute upper limit. An
553 absolute upper limit doesn't make much sense, because in our data
554 all arrival times are shifted at the same time (in fact it might be
555 a shift of the artificial trigger w.r.t. to the light flash).
556
557 - callisto: Added a new tab "BadPixTm" which shows the time evolution
558 of the number of unsuitable pixels over the whole sequence. This
559 is usefull mainly to judge if an intermediate calibration had
560 problems.
561
562 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
563 of the number of dead pixels over the whole sequence. Dead pixels
564 in this context are unmapped pixels, i.e. pixels which could not
565 be interpolated, and thus are ignored in the further analysis.
566
567 - callisto: It is now possible to use the position of the maximum
568 of the spline as arrival time instead of the leading edge even
569 when using the integral for the signal. Therefor set the extraction
570 type to kIntegralRel ("IntegralRelative") and the relative height
571 ("HeightTm") to -1:
572 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
573 MJPedestalC1.ExtractSignal.HeightTm: -1
574
575
576
577
578 *** Version 1.1 (2007/04/27)
579
580 - general: The new class MGeomCamDwarf contains the camera geometry
581 for our prefered Dwarf camera and can be used to create general
582 geometries of roundish or hexagonal cameras.
583
584 - mars: The default cleaning is now abolute 8.5/4.0.
585
586 - mars: The resource file mars.rc now contains examples for MUX data
587
588 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
589 data containing only 10-bit information is still cooked down to
590 8-bit, by cutting away the lowest 8-bit.
591
592 - merpp: When reading raw data the data is now stored in a single
593 array. The lo-gain array is obsolete. The interface stays the same.
594
595 - callisto: To process the new MUX data use the resource file
596 callisto_mux.rc
597
598 - callisto: The -root and -raw options to read merpped raw data have
599 been removed
600
601 - callisto: If the -mc option is given the sequence-name can now be
602 replaced by the MC sequence number
603
604 - callisto: If the sequence file contains "MonteCarlo: Yes" the
605 -mc option can now be omitted
606
607 - callisto: Started further simplification by removing obsolete
608 dependancies on MCalibIntensity*Cams.
609
610 - callisto: removed unsused intensity calibration from MJCalibration
611 for further simplification
612
613 - callisto: for simplification removed references to
614 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
615 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
616 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
617 (this should at minimum change nothing at all, and at maximum
618 improve thing if these containers where somewhere not handled
619 properly)
620
621 - callisto: Added the option to write an event movie. Please use
622 this option with care (huge files) but exessively to understand
623 our events. For further documentation please refer to the
624 IACT wiki
625 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
626
627 - callisto: Improved binning for the pulse position check histogram
628
629 - callisto: The code calculating the pulse position checknow takes
630 the pedestal into account
631
632 - callisto: The arrival time is now stored with full precision this
633 helps to get rid of artefacts in histograms. For the signal this
634 is not necessray because it is displayed in log-scale anyhow
635
636 - callisto: Fixed a problem with internal exclusions. Pixels which
637 have once been marked as unsuitable didn't get the necessary
638 histograms filled anymore to be rechecked with each interleaved
639 calibration.
640
641 - callisto: The relative arrival time resolution (the rms of the
642 relative arrival time offset) is now checked against its
643 median and the median deviation, instead of the average
644 plus an absolute offset.
645
646 - callisto: The relative arrival time offset is now calculated
647 w.r.t. its median not w.r.t. to an artificial reference pixel.
648
649 - callisto: The relative time calibration now marks pixels with
650 outlaying offset as unsuitable
651
652 - callisto: The interleaved relative time calibration has been switched
653 on. The advantage is that pixels which are marked as outliers
654 now can recover. An improvement over time is not expected, because
655 the relative time calibration seems stable.
656
657 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
658 option can now be omitted.
659
660 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
661 or the option "-mc" is specified as default the monte carlo datacenter
662 paths (/magic/montecarlo/...) are used if not overwritten in the
663 dataset file.
664
665 - ganymed: The output files now contain run- and event-number for all
666 events, accessible as RunNumber.fVal and EvtNumber.fVal
667
668 - ganymed: Added a plot showing the source position in the camera also
669 for wobble mode
670
671 - ganymed: In addition to the existing task which can be setup to
672 be executed after Cut1 a final task called "EstimateEnergy"
673 has been added, executed before writing the final output
674 (ganymed00000000.root). The task setup in all three cases
675 can be choosen individually. (For all three(!) cases you
676 can for example choose MRanForestCalc. For examples see all
677 sponde*.rc and all ganymed*rc)
678
679 - ganymed: If a container "MEstimatedEnergy" is found in the
680 parameter list (eg. because it was setup by MEstimateEnergy)
681 it will be written to the output file.
682
683
684
685 *** Version 1.0 (2007/02/16)
686
687 - database: Website to plot values from the database has been added.
688
689 - database: The rate of spark events as found by star is now kept
690 and the rate after cleaning is now with spark events subtracted
691
692 - general: The changes to the interpretation of phrases lead to
693 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
694
695 - general: Added example files how you can create your own calendar
696 (eg. as christmas present) with Mars. Just run
697 root macros/tutorials/calendar.C
698
699 - general: Added a possibility to display grouped data in the plotdb.C
700 macro (and similar macros). This allows to plot hourly, nightly,
701 weekly, monthly and yearly averages.
702 For more details see the plotall function of the macro
703
704 - general: fixed the error display of the camera display. It showed
705 wrong results.
706
707 - general: fixed a memory leak when reading many MStatusDisplays
708
709 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
710 between a spherical and a parabolic mirror
711
712 - callisto: We have a new pulse position check which takes the properties
713 of the extractor automatically into account. So no need to set
714 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
715 left is done. If possible the lo-gain extraction start and hi-gain
716 extraction end is changed accordingly. If no proper extraction range
717 can be set (hi-gain too much to the left) an error is raised.
718
719 - callisto: New swapped pixels have been found and corrected
720
721 - callisto: Redone the signal extraction this includes:
722 + Unified the algorithms to extract the pedestal for all pedestal
723 extractions done
724 + Unification of hi- and lo-gain into one array
725 + Unification of hi- and lo-gain extraction for Spline and
726 Digital Filter (means now exactly the same algorithm is used,
727 not a copy-and-pasted one)
728 + Store pedestal subtracted data in a common place
729 + Improved extraction algorithms. If the algorithms search a
730 maximum but don't find one they don't return the maximum anymore
731 + Improved the extraction such that a information for signal
732 and time which is consistent is returned
733 + replaced the numerical spline with a (not slower) analytical
734 solution
735 + Lowered the saturation limit from 250 to 245 to make sure that
736 we are far away in all pixels from problems with the clock-noise
737 + The start of the lo-gain extraction is calculated from the hi-gain
738 arrival time. In case of saturation an estimation is used.
739 + the hi-gain window was extended to slice 16. This allows extraction
740 of very late pulses in single pixels or of huge hadron showers.
741 + Now uses the lo-gain extraction range for pedestal extraction,
742 not the hi-gain range in the lo-gain
743
744 - callisto: New hi-/lo-gain calibration constants have been produced
745 for all periods from the statistic of the whole period. They are
746 now used automatically depending on the periods. The old constants
747 where deviation in avarega about 2%-3%. The constants are very
748 stable from period to period (<<1%) except for exchanged channels.
749 In a few cases the constants used so far were off by 1%-2% (maybe
750 temperature effects?)
751
752 - callisto: To gain obsolete space we do not write the
753 MPedestalFundamental anymore. Also calibration and bad pixel
754 treatment is not done for it anymore because it has never been used.
755
756 - callisto: Fixed a bug in the seuqence handling which caused the
757 light condition to be ignored
758
759 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
760 basically the same as "Cleaned" but the distribution devided into
761 the events fullfilling a spark cut or being rejected by it.
762 This cut can be changed from star.rc (see example inside) by
763 the "SparkCut" directive
764
765 - star: Star displays now the average individual pixel-rate (IPR) versus
766 time and the average discriminator threshold (DT) of all pixels.
767
768 - optim: fixed a problem with the optim-macros which was due to a bug
769 in the new phrase parsing
770
771 - ganymed: To get a nice FalseSource plot (instead of the all-information
772 debug plot displayed as a standard plot) use the context menu
773 somewhere between the two upper plots, click on "DrawNicePlot"
774 and enjoy the result. (It is the same context menu which contains
775 the other options)
776 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
777
778 - ganymed/optim/train: The cut program, trainings- and optimization
779 macros could run with less files found than expected from the
780 sequence-files. No the execution is stopped in this case.
781
782 - ganymed: now stores the dataset in the output file with all information
783 contained (as sequence number, sequence path, data path) so that the
784 used dataset file can be recreated complete from the output
785
786 - sponde: now also allows the uasge of random forest
787
788 - sponde: added a plot showing the cut efficiency
789
790 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
791 errors (eg. effecting the collection area) because the errors of the
792 two histograms were swapped in the calculation, which makes a difference
793 in the case the histograms contains weighted events. Aditionally the
794 totalarea was incorrectly taken into account, which results in too small
795 errors, which makes a difference at low statistics were the errors
796 or the collection area dominate.
797
798
799
800 *** Version 0.10.3 (2006/10/23)
801
802 - database: Implemented ObservationMode flag in websites.
803
804 - database: For sequences there is now also the stoptime available on the
805 websites.
806
807 - database: Removed ManuallyChanged flag from sequence-info websites,
808 as it is not needed anymore with the new sequence building algorithm.
809
810 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
811 Class for calculation of confidence intervals (upper limits).
812 Use model 3 or 4 for upper limit calculation for MAGIC observations.
813 Please read the class instruction of TRolke for more information.
814
815 - general: The programs now return 0xfe if the requested resource file
816 doesn't exist.
817
818 - general: Errors comming from root itself are now not output to
819 stderr anymore but to our default (colored) log-stream.
820
821 - general: Changed the interface to TFormula such that now everything
822 is parsed by TFormula, which should allow to use phrases even
823 without paranthesis correctly parsed.
824
825 - callisto: replaced the AdHoc number of effective integration slices
826 in the digital filter by an average of the correct number, averaged
827 over all possible set of weights. This also gives correct numbers
828 for the lo-gains which were totally wrong before.
829
830 - callisto: drastically reduced memory consumption by not storing
831 all intermediate calibration results in memory anymore (we might
832 write them into a file in the future)
833
834 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
835 debug plot displayed as a standard plot) use the context menu
836 somewhere between the two upper plots, click on "DrawNicePlot"
837 and enjoy the result. (It is the same context menu which contains
838 the "DrawAll" option)
839 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
840
841
842
843 *** Version 0.10.2 (2006/10/15)
844
845 - general: changed the building of the sequence files such, that
846 the source-/project name in case of wobble-sources is not the
847 source/project of the first data run anymore but the new generalized
848 wobble source/project
849
850 - general: Added some functions to MAstro to calculate sun and
851 moon properties
852
853 - general: Added two new macros (starvisday.C and starvisyear.C)
854 which allow to plot the visibility of several stars in one day
855 or of one star along one year
856
857
858
859 *** Version 0.10.1 (2006/10/11)
860
861 - general: HTML logging output was distorted... fixed.
862
863 - general: Changed the writing of the sequencefiles such that only
864 as many pedestal files as giving at least 1000 pedestal events which
865 are nearby the first calibration run are used as pedestal runs
866
867 - sponde: In the calculation of the collection area(s) and the
868 distribution for MOnte Carlo and estimated energy the error
869 calculation was wrong because root didn't take the errors
870 properly into account... fixed.
871
872
873
874 *** Version 0.10 (2006/10/10)
875
876 - general: all executables now check consistency of the root version
877 installed with the root version used for compilation. The return
878 code in this case is 255.
879
880 - general: The algorithm to build seqeunces has been redesigned
881 completly. It is now more flexible in terms of a resource file
882 resources/sequences.rc which can be used to partly overwrite
883 the default algorithm and defined the important part of the
884 algorithm. It also takes correctly into account several ways
885 of taking wobble-data. Currently the new algorithm doesn't take
886 the number of pedestal events anymore into account (so a sequence
887 could have much less than 1000 pedestal events and data runs are
888 no-more used instead)
889
890 - general: a lot of small changes to make the code compatible with
891 root 5.12/00 and gcc 4.1
892
893 - general: Fixed some warnings thrown if more warnings are switched
894 on in the compiler
895
896 - general: Added a function to MMath which returns the Median of
897 the distribution abs(y[i]-median) but at 68:32 division instead
898 of 50:50, which is somehow the median counterpart of the rms.
899
900 - general: MAstroCatalog allows now to read calatog files (as bsc5)
901 even if they are compressed with gzip (recommended compression
902 is with "-1")
903
904 - showplot:
905 + batch mode creation of image files now works with root 5.12/00
906 + added support for writing bmp (though it never produces
907 bmp which can be read by programs like xv or gimp)
908 + added support for xml
909 + added new option to start the display with a different size, by
910 --display-width=nnn or --display-height=nnn
911 + added options to define the canvas size when the display is started
912 --canvas-width=nnn or --canvas-height=nnn
913 the option can also be used for batch-mode conversion
914 + added an option which automatically fits the display size to the
915 desktop-size: --auto-size
916
917 - merpp: didn't recognize files with the extension .raw.gz - fixed.
918
919 - merpp: allow the reports to have 1000ms due to a bug in the camera
920 program.
921
922 - callisto: New swapped pixels have been found and corrected. For
923 details see MRawRunHeader::FixAssignment()
924
925 - callisto: Callisto now raises an error if one of the input files could
926 not be opened.
927
928 - callisto: In some rare cases it could happen that in the signal
929 extraction of the digital filter the extractor returned nonsense
930 results due a wrong initializion of a variable (this happens in
931 cases in which the extracted signal is exactly zero or the
932 digital filter couldn't slide because of a too small extraction
933 window, which could happen in the lo-gain extraction)
934
935 - callisto: The lo-gains have been marked as valid in some cases
936 when they got not extracted at all (deltsumlo=deltatimelo=0) because
937 the allowed extraction range (fLoGainLast-fLoGainFirst) was
938 smaller than the number of slices (fLoGainWindowSize) needed
939 by the lo-gain extractor
940
941 - callisto: Updated absolute calibration constants (muon calibration)
942
943 - callisto: fixed a bug which caused the hi-gain saturation not
944 to be handled properly in the spline (the position of the
945 saturation was calculated incorrectly)
946
947 - callisto: fixed a bug which gave weird results if hi- _and_
948 lo-gain could not be extracted properly. In some cases hi-
949 and lo-gain have not been extracted at all and the random result
950 got calibrated. In other cases the hi-gain was saturating and the
951 lo-gain has not been extracted. For this a completly arbitraty
952 scale factor was applied to the result from extracting the
953 charge of the saturating hi-gain.
954
955 - callisto: improves handling of extracted signal if lo- and/or
956 hi-gain could not be extracted properly. If no appropriate
957 calibration of either the signal or the arrival time is possible
958 the pixel is now markes as unsuitable instead of estimated.
959
960 - callisto: Fixed a problem in the spline extraction which gave
961 weird results if the signal was extracted from the first (and
962 highest) slice (as a workaround extraction from the first
963 slice has been forbidden)
964
965 - callisto: Fixed a bug regarding the use of the QE which doesn't
966 effect the result because the default is used anyhow.
967 (The bug was there since 14/07/2005)
968
969 - callisto: Changed the default for fgLoGainStartShift to -2.4
970
971 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
972 factors to be always 10 for all pixels as soon as the first
973 calibration update has happend.
974
975 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
976 was off by more than one slice (which gives wrong values for
977 pixels which have saturated the hi-gain) This was a problem
978 mainly for timing studies, not so much for the automatic standard
979 analysis. Also the values for the Spline have been changed slightly:
980 + Digital Filter from 1.70 to 0.95
981 + Spline from 1.39 to 1.30
982 The numbers were sorted out by an extensive test in the
983 test-database.
984
985 - callisto: Removed the tab showing the average calibrated arrival
986 time. It never gave useful information.
987
988 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
989 lo-gain pulse for data pulses if hi- and lo-gain have saturated
990 and both were extracted because the hi-gain was above the
991 LoGainSwitch.
992
993 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
994 lo-gain pulse position (after application of LoGainOffset, which
995 means in the ideal case it is 0) for data pulses if hi- and lo-gain
996 have saturated and both were extracted because the hi-gain was above
997 the LoGainSwitch.
998
999 - callisto: After extensive tests a new threshold level for determination
1000 of the pulse position has been found at 50phe. This is due to the
1001 fact that for lower pulses the arrival time changes its average
1002 behaviour dramatically. It tends to the average of the extraction
1003 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1004
1005 - callisto: Added two more plots to the calibration part. The average
1006 extracted signal and the average extracted arrival time as
1007 extracted by the signal extractor (This can help debugging problems
1008 because it doesn't involve a fit)
1009
1010 - star: changed the fit for the effective on time such that initial
1011 values are calculated automatically now instead of using build
1012 in values. This makes the fit more indepedant of the underlaying
1013 rates. With a test of ~350 sequences in the test database it could
1014 be shown that the new fit gives the same result +/-1sek.
1015 The highest deviation was +5s the lowest -10s. You can now control
1016 the bahaviour with two resource values:
1017 MHEffectiveOnTime.FistBin: 3
1018 MHEffectiveOnTime.NumEvents: 12000
1019 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1020 from the resulting gamma candidates
1021
1022 - star: The Center histogram in MHHillas is now by default displayed
1023 with the colz draw-option
1024
1025 - ganymed: now produces valid error codes if failed
1026
1027 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1028 with the option "hadronness" instead of "area" or "both" if
1029 you want to use both cuts. The hadronness cut includes a fixed
1030 cut in hadronness (index 8) and a fixed cut in size (index 9).
1031
1032 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1033 the M3Long of the anti source to be not properly evaluated
1034 (actually is was evaluated as a unique random number) in case
1035 of optimization with anti-theta cut switched on. This might have
1036 lead to improper, but not necessarily wrong, optimization results.
1037
1038 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1039 how to use random forest
1040
1041 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1042 ganymed_onoff.rc. Seems to be unintentional that they were different.
1043
1044 - sponde: Since the introduction of the possibility to define a
1045 normalization energy instead of using the integral the default
1046 was not using the integral anymore but a normalization energy of
1047 1GeV. It is now the integral again.
1048
1049 - sponde: Fixed a problem in the weighting which did not allow
1050 a MC slope of -1.
1051
1052
1053
1054 *** Version 0.9.6 (2006/05/24)
1055
1056 - general: changed the binning of the azimuthal profile of the camera
1057 such that it is aligned with the 60deg boundaries.
1058
1059 - merpp: better handling of problems with the TH, TD part of the
1060 CC-REPORT for files older than 200507190 and 200412210
1061 respectively
1062
1063 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1064
1065 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1066
1067 - callisto: if an arrival time is extracted outside the fadc range is
1068 was set to the boundary before. Now a random number is assigned
1069 instead to avoid unfortunate coincidences of arrival times just
1070 by this arbitrary value.
1071
1072 - callisto: added a new option to callisto.rc which allows
1073 to set the maximum arrival time difference allowed for the
1074 badpixel algorithm to determin whether a pixels belongs to a shower:
1075 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1076
1077 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1078 to 0.9 as suggested by Stefan due to a recent study on the fraction
1079 of pixels surviving the image cleaning
1080
1081 - callisto: switched off error in case of "pulse is too much to the left"
1082
1083 - callisto: The extraction window is not adapted anymore. This means that
1084 the pulse is extracted from the full range. The draw-back is that the
1085 background (pedestal) will become slightly higher. Switching on/off
1086 the PulsePosCheck in the callisto.rc only effects filling the
1087 histograms.
1088 WARNING: If the pulse is too much to the left data is calibrated!
1089 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1090 in the database to make sure that your data is valid!
1091
1092 - star: Show also the number of stars correlated correctly by the
1093 starguider
1094
1095 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1096 than one off-source region in wobble-mode. To use it add the following to
1097 your ganymed_wobble.rc:
1098 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1099 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1100 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1101 + Cut1.ThetaCut: None
1102 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1103
1104 - ganymed: in the case the latest report is older than a default (currently
1105 one minute) and the current report will be skip the starguider
1106 correction and calibration will be reset. The maximum age can be
1107 setup from ganymed.rc by (minutes):
1108 MPointingDevCalc.MaxAge: 1.5
1109
1110 - ganymed: A first implementation showing all size-bins for the theta-sq
1111 resp. alpha-plots in a single tab automatically
1112
1113
1114
1115 *** Version 0.9.5.1 (2006/05/05)
1116
1117 - general: Added a new option "zdiff" to the Makefile which runs
1118 "cvs diff" as "make diff" would do, but with compression
1119
1120 - general: accelerated MTFillMatrix (used for eample in all training
1121 and optimization macros) by skipping some obsolete calles in the
1122 eventloop the first and second loop could be accelerated by ~20%
1123
1124 - general: Added a missing feature in the MFilterList class which
1125 prevented MFEnergySlope from working correctly in trainenergy.C
1126
1127 - general: Accelerated the random forest training and usage a bit
1128
1129 - merpp: Adapted to new raw data file format version 6
1130
1131 - merpp: fixed a problem with reading the starguider reports
1132 after 6.3.2006
1133
1134 - callisto: At some times six pixels had to be exchanged manually in the
1135 data. If the pixels to be swaped are both not found, an error was raised
1136 and calibration was stopped. Now it is assumed they are intentially not
1137 mapped and the Error has been changed to a Warning.
1138
1139 - star: Added new image cleaning based on the arrival time of the shower.
1140 The new cleaning can be accessed using the parameter "Time" instead of
1141 the the old one (like "Absolute) in the star.rc-file.
1142 Recommended parameters:
1143 + MImgCleanStd.CleanLevel1: 8.2
1144 + MImgCleanStd.CleanLevel2: 5
1145 + MImgCleanStd.CleanRings: 2
1146 + MImgCleanStd.KeepSinglePixels: No
1147
1148 - star: Simplified the calculation of the effective on time. By letting
1149 the fit start in the third bin the result should become more stable.
1150 The fit quality is now ignored for the theta-plot which is not used
1151 in the analysis later. Still better pre-cut which, for example,
1152 remove events triggered by car-light (rate changing on a short
1153 time-scale) are missing.
1154
1155 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1156 for optimization (kWeakSource) which is suggested by the Berlin
1157 people for weak sources.
1158
1159 - macros: plotdb.C:
1160 + if no dataset and no time-interval is given only sequences with
1161 an effective on-time above five minutes are plotted anymore
1162 + added a new tab "RelTime" displaying the relative on-time
1163 (effective on-time divided by the observation time)
1164
1165 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1166 the optimization became a lot faster
1167
1168 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1169 To display them just delete the pads displayed on top.
1170
1171 - ganymed: fixed a bug which could cause strange behaviour in wobble
1172 mode if no starguider information was available due to an incorrect
1173 initialization of the starguider calibration
1174
1175 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1176 be changed from within the plot. It can also be setup from the
1177 resource file using:
1178 + MHDisp.fScaleMin: 0.325
1179 + MHDisp.fScaleMax: 0.475
1180
1181 - ganymed, showplot: Fixed a problem with the fit to the off-data
1182 (HistOff) which could cause a time lag or an inifinite loop.
1183 The bug did not effect the results at all.
1184
1185 - sponde: Added a new tab showing the effective collection area after
1186 trigger (including the software trigger)
1187
1188 - sponde: MMcSpectrumWeight has a new option which allows to define
1189 the scaling factor not by the integral of the events but at
1190 a defined energy:
1191 e.g. MMcSpectrumWeight.NormEnergy: 200
1192
1193 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1194 eventloops the loop could be accelerated by ~20%
1195
1196
1197
1198 *** Version 0.9.5 (2006/03/13)
1199
1200 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1201 and added the standard Disp-parametrization
1202
1203 - macros: added a new macro datacenter/macros/plotstat.C allowing
1204 to plot statistics about the data processing
1205
1206 - macros: added a new macro to plot the muon correction coefficients
1207 versus period (macros/plot/mucal.C)
1208
1209 - showplot: path inflation for ganymed files was broken
1210
1211 - callisto: Fixed an important bug. When the number of saturating pixels
1212 were calculated the bad pixel information already available from the
1213 calibration was ignored. This yields wrong values in case pixels
1214 are broken and saturate all the time or randomly.
1215
1216 - callisto: Updated Muon calibration constants. Spline data now also uses
1217 different values for different periods
1218
1219 - star: The time-evolution shown in the effective on-time plot now displays
1220 the axis range (if there are no holes it should be similar to the
1221 effective on-time)
1222
1223 - star: Added two new image parameters:
1224 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1225 the three pixels next to the center of gravity and the size
1226 + MNewImagePar.fConcCore: The ratio of the signals of all
1227 pixels inside or touching the ellipse and the size
1228
1229 - ganymed: now stops in requested source isn't found in catalog file
1230
1231 - ganymed: Many improvements to the phi-plot in wobble mode:
1232 + with a template the ideal background is displayed
1233 + a possible camera inhomogeneity is taken into account
1234 + the anti theta cut is better supported
1235 + the phi cut is automatically calculated from the theta cut
1236 See the examples in ganymed_wobble.rc for more details.
1237
1238 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1239 times the bin-width instead of the absolute energy
1240
1241 - ganymed: New cuts for on/off and wobble mode
1242
1243 - ganymed: The smearing of the False Source plot has been increased
1244 to 0.06
1245
1246 - ganymed: The starguider calibration can now be changed from the
1247 resource file.
1248 See the examples in ganymed*.rc for more details.
1249
1250 - ganymed: added a new option for on-/off-observations
1251 MJCut.RandomSourcePosition
1252 If switched on the distribution of observation time of the source
1253 position in the camera is calculated from the on-data and randomly
1254 applied with this distrbution to the off-data.
1255
1256 - ganymed: by skipping some obsolete calles in the eventloop the
1257 first and second loop could be accelerated by ~20%
1258
1259 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1260 position in the off-data randomly according to its distribution in the
1261 on-data.
1262
1263
1264
1265 *** Version 0.9.4.3 (2006/02/13)
1266
1267 - general: Fixed a bug in most of the programs which prevented the
1268 compile date in the startup message to be displayed
1269
1270 - general: Simplified program calls. The following abbreviations
1271 are now possible:
1272 showlog callisto 55599
1273 showplot signal 55599
1274 star 55599
1275 callisto 55999
1276 ganymed 2
1277 In this cases the corrsponding root-, log-, sequence- or dataset-
1278 filename is automatically compiled using the default datacenter
1279 paths ("/magic/*")
1280
1281 - general: Fixed a long outstanding bug which made axis tick marks
1282 disappear if MDataFormula was used (eg. abs(x))
1283
1284 - general: Updated MMath with new functions to calculate the results of
1285 a exponential, logarithmic and powerlaw fits analytically.
1286
1287 - general: Updated some macros with comments:
1288 + macros/optim/optimdisp.C
1289 + macros/optim/optimenergy.C
1290 + macros/optim/optimwobble.C:
1291
1292 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1293 files) now allows adding a pre-cut like in the optimization. E.g. this
1294 is useful to perform g/h-separation cuts before training the random
1295 forest.
1296
1297 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1298 correctly assigned in the raw data assignement table. A fix to correct
1299 the assignment tabel have been implemented.
1300
1301 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1302 by 90, 180 and 270 deg.
1303
1304 - general: the macro plotdb.C now allows to highlight sequences belonging
1305 to a datset. For more details see the descritions in the macro.
1306
1307 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1308 of the display, it gave wrong results espacially for big sizes.
1309 Now the embedded canvas should always have a ratio width/height=3/2.
1310 The "Size" options have been updated with values fitting the 3/2
1311 size ratio.
1312
1313 - RanForest:
1314 + Updated the random forest classes to support also the
1315 regression method implemented by Thomas H.
1316 + added new tutorial macro how to train the random forest
1317 for energy estimation (macros/optim/rfenergyest.C)
1318 + new classes to train the random forest (still in development)
1319 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1320 + new tutorial macros for random forest training in macros/train
1321 trainenergy.C, traindisp.C, trainseparation.C
1322
1323 - mars: now allows to setup a cut in the resource file mars.rc to choose
1324 the events to be displayed, eg:
1325 Cut.Condition: {0} && {1}
1326 Cut.0: MHillas.fSize>100
1327 Cut.1: MHillas.fSize<900
1328
1329 - merpp: Made aware of the new .rep format 200510250. This includes
1330 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1331 the discriminator thresholds (MCameraTD) and the disciminator
1332 delays (MCameraTD). All of them come with the CC report and are therefor
1333 written to the CC tree.
1334
1335 - callisto: fixed a bug in the calculation of the arrival times in
1336 the Digital Filter. They were all shifted by the same amount
1337 fHiGainFirst. This caused an offset in the order of the position of
1338 the left border of the extraction window in the times calculated
1339 from high-gain and from low-gain. The bug effected only the absolute
1340 arrival times. The bug was there since 30.1.2005.
1341
1342 - callisto: Changed the ExtractionWindow for the pulse position check
1343 such that the camera inhomogeneity becomes as less as possible and
1344 comparable to the pulso position check switched off. More details
1345 on the study will be given at our result web-page.
1346
1347 - ganymed: ganymed.rc, ganymed_onoff.rc:
1348 changed to new cuts trained with 1ES1218 and Crab-data
1349 for maximum sigma*log10(excess)
1350
1351 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1352 a new option was implemented to estimate Disp (CalcDisp)
1353
1354 - ganymed: Implemented two new options which allow
1355 to overwrite the default path to search for the sequence files
1356 --ins=/magic/sequences
1357 and where to search for the image data
1358 --ind=/magic/data/star
1359
1360 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1361 dx/dy from the resource file by
1362 MSrcPosCorrect.Dx
1363 MSrcPosCorrect.Dy
1364
1365 - ganymed: fixed reading the source catalog. Only as many chars
1366 as the requested source name had were compared (If a source
1367 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1368 were requested it could happen that the coordinates of
1369 "1ES1218" were read) The source coordinates are now printed
1370 in addition to its name to the logging output.
1371
1372 - ganymed: changed the background fit in the case of a ThetaSq function
1373 from a polynomial to a exponential, this should give a big improvement
1374 for on-only analysis'
1375
1376 - ganymed/sponde: Calculation of the error of single size-/energy-
1377 bins now uses Li/Ma (5) instead of LiMa (17)
1378
1379 - sponde: Added a plot E^2*dN/dE
1380
1381 - sponde: The energy estimator plot should now show values like
1382 they are commonly used.
1383
1384 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1385 (a powerlaw with cutoff didn't work before)
1386
1387
1388
1389 *** Version 0.9.4.2 (2005/10/01)
1390
1391 - general: added new tutorial macro macros/tutorials/threshold.C:
1392 how to calculate the threshold
1393
1394 - general: added a new game. Start it from the interpreter with
1395 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1396 and MagicReversi)
1397
1398 - general: neighbor pixels in MGeoms are now sorted clockwise
1399
1400 - merpp: made aware of new format 20050829-0
1401
1402 - callisto: New scale factors from muon analysis, stored in new
1403 resource file resources/calibration.rc
1404
1405 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1406 the eventloop if something went wrong. This is necessary for the
1407 automatic processing
1408
1409 - callisto: Implemented a new treatment for the time information
1410 developed by S.Ruegamer, this should give much better response than
1411 the old very primitive algorithm. This is especially important
1412 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1413 treatment was buggy! As neighbor pixels to interpolate the
1414 arrival times always the pixels 0 to 5 were taken)
1415
1416 - callisto: In addition to the new treatment of arrival times the
1417 decision of the treatment whether a pixel contains shower
1418 information or not is used to improve the signal interpolation
1419 further. Previously interpolated pixels showed a non-zero signal
1420 do the peak searching signal extractors. Having a signal pixel
1421 beside raised the signal above the cleaning level. Thus the
1422 pixel survived cleaning to often but with a too low mean signal.
1423 By replacing empty pixels with a gaus (mean and rms from the
1424 corresponding Area entries in MPedPhotCam) this effect can
1425 be supressed.
1426
1427 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1428 got lost when the events were stored by the calibration... fixed.
1429 (This was no problem for normal image cleaning because the pixel
1430 content was artificially set to 0 not surviving standard cleaning
1431 algorithm)
1432
1433 - callisto: Fixed a bug which caused the random and peak-search pedestal
1434 extracted with an extractor to be exchanged for the first (roughly)
1435 500 events (*Extractor and *ExtractorRndm).
1436 (They were simply exchanged in callisto.cc) This bug might have been
1437 introduced in Mars 0.9.4 when the order of calculation of the two
1438 types of pedestal in callisto got exchanged. The bug only effects
1439 the first seconds of data of each sequence.
1440
1441 - star: Taking the arrival time of Muons into account the calculation
1442 of the parameters could be made independant of the noise
1443 (pedestal rms). The dependance was due to the bias of the peak search
1444 extractor. Now only a ZA dependamcy is left which is not yet fully
1445 understood.
1446
1447 - ganymed: The sequences were still not sorted correctly in any case,
1448 because they were sorted by the full qualified path name. Now they
1449 are sorted by their sequence number.
1450
1451 - ganymed: new values for the spark-event-cut
1452
1453 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1454
1455
1456
1457 *** Version 0.9.4.1 (2005/08/18)
1458
1459 - callisto: fixed some problems with the calibration in case of
1460 inteleaved events. Therefor the final and some intermediate
1461 fits are skipped which would take place on partly filled #
1462 histograms and gave wrong results or failed completely.
1463
1464 - callisto: If the intermediate finalization of the histograms
1465 calculating the mean charge of the calibration signal fails
1466 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1467
1468 - ganymed: Fixed some bugs which caused problems in On-only mode.
1469 Still the false source plot doesn't give reasonable results.
1470
1471
1472
1473 *** Version 0.9.4 (2005/08/05)
1474
1475 - general: Fixed the ZA binning. It did not correctly fit the
1476 MC binning
1477
1478 - general: Added a class to correct for the missfocussing in
1479 April (MSrcPosCorrect)
1480
1481 - general: Random Forest energy estimator should now work properly
1482
1483 - general: MHCamera now displays the profiles in deg instead of mm
1484
1485 - general: MH::SetPalette offers a lot of new palettes
1486
1487 - general: MHillas - the case of CorrXY==0 is now handled properly
1488
1489 - general: implemented the possibility to change the line and
1490 marker style of a sky-grid drawn by MAstroCatalog
1491
1492 - general: Runs in sequences and datasets are now automatically
1493 ordered (it is assumed that the order of their filenames correctly
1494 represents the order of observations) to ensure correct reading
1495 of the subsystem data
1496
1497 - general: Runs cannot be added to a sequence twice anymore. Also
1498 Sequences cannot be added twice anymore to a dataset.
1499
1500 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1501 It gave wrong results by 1./2pi
1502
1503 - showplot: got a new option to start a root interpreter, too
1504
1505 - mars: now displays a rough estimate of Disp and the third moment
1506
1507 - mars: now displays the event time MTime if available
1508
1509 - mars: show muon parameters graphically
1510
1511 - mars: now the file to open can be given as commandline
1512 argument
1513
1514 - merpp: Added support for new arehucas version >= 200507190
1515 implementing values for three temperature sensors in the
1516 counting house (MCameraAUX) and the name of the HV settings file
1517 (MCameraHV).
1518
1519 - merrp: Also fixed some problems with wrong versions numbers stated
1520 by arehucas and implemented some fixed for old versions (<200407070)
1521
1522 - callisto: MCalibrationHiLoCam can now be printed from its context
1523 menu, eg in the TBrowser
1524
1525 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1526 - 1.39 (MExtractTimeAndChargeSpline)
1527 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1528 This is important mainly for timing studies.
1529
1530 - callisto: Changed limits in MHCalibrationChargeCalc from
1531 - -100.125 to -98 (fgChargeHiGainFirst)
1532 - 1899.875 to 1902. (fgChargeHiGainLast)
1533 - -100.25 to -99 (fgChargeLoGainFirst)
1534 - 899.75 to 901. (fgChargeLoGainLast)
1535 Introduced new limits:
1536 - fgNumLoGainBlackoutLimit: 0.05
1537 - fgLoGainBlackoutLimit: 3.5
1538 - fgLoGainPickupLimit: 3.5
1539
1540 - callisto: The handling of automatic weights for the digital filter
1541 has been improved. There are now new calibration weights special
1542 for Monte Carlo calibrations.
1543
1544 - callisto: Updated Muon scale with latest results (1% difference
1545 for most data, 5% for Mar/Apr'05)
1546
1547 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1548 was saturated and the blackout-events in the low-gain exceed the
1549 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1550 This excludes those pixels which have a saturating high-gain
1551 channel, but the low-gain switch does not switch often enough
1552 to make the distribution reliable.
1553
1554 - callisto: fix a bug counting the number of saturated events. Up to now,
1555 the number of saturated slices was counted (which is one for a not too
1556 high number), but for some (pathological) pixels, many more slices
1557 saturated and produced wrong limits.
1558
1559 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1560 + MCalibrationRelTimeCam.CheckFitResults: Yes
1561 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1562 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1563 + MCalibrationRelTimeCam.CheckOscillations: Yes
1564
1565 - callisto: introduce max. number of events for intercalibration,
1566 the rest gets skipped. Default: 4096
1567 The calibration causes too many un-reliable pixels if more
1568 than about 5000 events are treated (@500 Hz) because of the
1569 mode hopping of the VCSels. However, in the past, some
1570 calibration runs have been taken (erroneously) with more
1571 than 5000 events, especially the intensity scans where
1572 a good precision is needed.
1573
1574 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1575 photo-electrons for the spline extractor by 1-2% (correctly).
1576
1577 - callisto: The intercalibration is now done using a full f-factor
1578 method instead of a simple update. This makes things slower but
1579 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1580 changes.
1581
1582 - callisto: MPedestalY3 now uses the same extraction range as the data
1583 as calculated by MPedestalY2
1584
1585 - callisto: A check of the fraction of allowed unsuitable (10%) and
1586 unreliable (30%) pixels has been addded when the conversion is
1587 calculated from interleaved events
1588
1589 - star: fixed a bug which caused MEffectiveOnTime containers not to
1590 be written. In the worst case they were skipped almost all, in the
1591 best case they were all ok. It depends on how often the new value
1592 was assigned just with an event which was skipped later by another
1593 task
1594
1595 - star: new histograms MHPointing and MHRate
1596
1597 - star: New tab (Currents) displaying the time evolution of the mean
1598 DC currents
1599
1600 - star: New tab (MeanRms) displaying the time volution of the mean
1601 Pedestal Rms
1602
1603 - star: Output now contains MReportStarguider
1604
1605 - star: Improved muon analysis. Due to the absense of a constant
1606 for the gaus fit for arc width and the fact that the arcwidth
1607 plot was a histogram instead of a profile the resulting psf
1608 became pedestal rms dependant
1609
1610 - ganymed: added new plot (MHPhi) for wobble mode as described in
1611 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1612
1613 - ganymed: corrects now (correctly?) for the misspointing in
1614 May/April 05
1615
1616 - ganymed: Two new default templates for ganymed.rc are avilable:
1617 ganymed_onoff.rc and ganymed_wobble.rc
1618
1619 - ganymed: The first version of MFMagicCuts has been released
1620
1621 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1622
1623 - ganymed, sponde: There are two new options to determin the number
1624 of bins for the signal region (NumBinsSignal) and the number of
1625 total bins (NumBinsTotal) in the MHThetaSq histogram
1626
1627 - ganymed: optimized palettes for MHDisp
1628
1629 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1630 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1631 sqrt(2) to large
1632
1633 - ganymed: The false source plot (MHDisp) is now based on Disp
1634 and a background model determined in the first loop is
1635 subtracted
1636
1637 - ganymed: MFMagicCuts are now available in the cvs. The correct
1638 solution for the disp ambiguity problem is now calculated using
1639 the third moment. The third moment cut therefor is skipped.
1640
1641 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1642 already determined by the third moment along the major axis and
1643 so its actual sign is aligned along the major axis of the shower.
1644
1645 - ganymed: If starguider data is available it is taken into account
1646 when calculating the source position. This is especially important
1647 for wobble data at high zenith angles and culmination data.
1648
1649 - ganymed: If available the starguider data is taken into account as
1650 good as it is possible without a starguider calibration. To switch
1651 it off add
1652 MPointingDevCalc.MaxAbsDev: -1
1653 to your ganymed.rc
1654
1655 - sponde: the zenith angle distribution is now weighted instead of
1656 choosen by default. This gurantees higher statistics in the highest
1657 and lowest energy bins. To switch this behaviour off use...
1658
1659 - sponde: now automatically displays the energy threshold
1660
1661
1662
1663 *** Version 0.9.3 (2005/06/03)
1664
1665 - general: MMcEvt now derived from MMcEvtBasic which should
1666 have no influence on compatibility with older camera files
1667
1668 - general: Implemented a new option to MReadReports which allows
1669 to force reading of the first event of some trees (eg. Drive-tree)
1670 before any other tree.
1671
1672 - general: Made a fix to MPointingPosCalc which assumes that the
1673 run-type is real-data if Process is called before ReInit, such
1674 that also the very first Drive-events in a run are treated
1675 correctly.
1676
1677 - shoplot now displays the filename in the title bar of the window
1678
1679 - merpp: new options: --auto-time-start --auto-time-stop which
1680 allow to cut updating with slow-control at the start- or
1681 (previousle --auto-time only allowed: and) stop-time of
1682 the run stored in the runheader.
1683
1684 - callisto: changed default of fgFallTimeHiGain in
1685 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1686 already set as default in callisto_Dec04Jan05.rc
1687
1688 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1689 now changes the filename for new weights automatically for
1690 cosmics, MC and for different calibration colors.
1691
1692 - callisto: a problem with the order of some code cause the
1693 name of the weights file in MPedestalY2 to be ignored.
1694 Wrongly the calibration_UV weights were used instead
1695 of the cosmics weights set in callisto.rc.
1696
1697 - callisto: should allow ct1 pulser data when the color is
1698 explicitly set also for pretty new runs
1699
1700 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1701 to introduce an additional scale factor (should be around 1)
1702 to adapt for slight deviations in different extractors from
1703 the MC calibration. For MC calibrations the scale factor
1704 is fixed to 1
1705
1706 - callisto: MFCosmics should handle very high signals a bit
1707 more accurate now
1708
1709 - callisto: when calculating the mean pedestal rms for different
1710 pixel sizes or sectors also kUnsuitableEvt is now taken into
1711 account - not only kUnsuitableRun
1712
1713 - callisto: '-raw' option is now the default
1714
1715 - callisto: A dead pixel check has been implemented in MJPedestalC2.
1716 This has the advantage that mean values in the calibration (eg
1717 arrival times) are calculated more accuratly.
1718
1719 - callisto: In the resource file callisto_Dec04Jan05.rc
1720 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
1721
1722 - callisto: new Hi-/Lo-Gain intercalibration constants
1723 hilocalib_sp1.root and hilocalib_sp1_mc.root
1724
1725 - callisto: changed default for MJPedestalY2.MaxEvents
1726 from 2000 to 5000 like in callisto_Dec04Jan05.txt
1727
1728 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
1729 has changed from 9.0 to 6.0. This is necessary to exclude two very
1730 ringing pixels in September which - when kept - destroy the image
1731 cleaning around them (Markus G.)
1732
1733 - callisto: (!) The Muon analysis of all data taken so far has
1734 suggested that different extractors give slightly different
1735 absolute results after calibration, due to there different
1736 handling of the calibration- and cosmics pulse shape. Although
1737 the over all calibration seems to be a bit to pesimistic (or
1738 the MC seems to be a little bit - 3-5% - too much attenuated).
1739 There for correction factors have been introduced which correct
1740 the calibration constants by
1741 0.956937799 for Digital Filter (callisto.rc)
1742 and
1743 0.904159132 for Spline (callisto_Dec04Jan05.rc)
1744 calibration. The main advantage is, that both data types can
1745 be easily analysed together and compared to the same MC sample.
1746 The factors are choosen such, that the reference is now a
1747 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
1748
1749 - star: fixed a bug which caused the first bin of the histograms
1750 vs time to disapear in PostProcess. This gave wrong results
1751 on the screen. The output and all following programs not
1752 directly accessing the histograms haven't been affected
1753
1754 - star, ganymed: Made sure that always the first Drive-tree event
1755 is read and Processed before the first data event was read.
1756
1757 - ganymed: implemented the possibility to replace the standard
1758 false source plot with a different one. For example: If
1759 you want to use a Disp based FS plot use the resource:
1760 NameHistFS: MHDisp
1761 For details about the requirements of these plots look
1762 at the corresponding classes
1763
1764 - MJOptimize: For On/Off and Wobble optimization MJOptimize
1765 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
1766 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
1767 case MAlphaFitter is setup correctly. For On-Only optimization
1768 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
1769 RunOn() instead of Run(). For energy estimation MJOptimize
1770 has been replaced by MJOptimizeEnergy
1771
1772 - sponde: The input MC spectrum can now be weighted to fake a
1773 different spectrum. This is done via MMcSpectrumWeight. For
1774 more details see the class description and sponde.rc
1775
1776 - sponde: The paremeter comparsion plots are not scaled by
1777 their entries anymore. Instead the MC plot is scaled by using
1778 the result spectrum of the analysis. If the input MC spectrum
1779 and the result spectrum has different slopes the absolut
1780 normalization is normally wrong.
1781
1782
1783
1784 *** Version 0.9.2 (2005/05/20)
1785
1786 - general: Changed the default paths for calibrated data and image
1787 files. (The implemented access to these files doesn't yet exist)
1788
1789 - general: support for MRunIter has been removed from the job classes
1790 (use the setter functions of MSeqeunce instead)
1791
1792 - general: ProcessFile has been renamed to Process in all job classes,
1793 because ProcessFile is missleading
1794
1795 - general: The storage of the palette in MHCamera is now possible
1796
1797 - general: new bits describing unsuitable and unreliable pixels have
1798 been introduced in MBadPixelsPix: kPreviouslyExcluded,
1799 kDeadPedestalRms, kFluctuatingArrivalTimes
1800
1801 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
1802 versions newer than V200404070
1803
1804 - general: support for cc file versions newer than V200504130. Added
1805 support for active loads (MCameraActiveLoad) and central pixel
1806 (MCameraCentralPixel)
1807
1808 - general: added new histograms for image parameters versus size
1809 (MHVsSize)
1810
1811 - general: The eventloop now automatically calls PrintStatistics
1812
1813 - Status Display: Improved support for printing:
1814 + A default can now be set in .rootrc (for more details see
1815 MStatusDisplay::PrintPS)
1816 + A print dialog is opened so that printer and command line
1817 can be canged
1818
1819 - showlog: improved such that it handles different verbosity levels
1820 more accurate now. This mean you can suppress output when
1821 using showlog.
1822
1823 - showplot: improved
1824 + The new graphics formats have been implemented
1825 (pdf, svg, png, jpg and xpm)
1826 + Implemented an interface for printing. Because you can change
1827 the printing command from the command line you can use all
1828 the nice postscript tool. To print a booklet for example call:
1829 showplot -b --print --print-cmd="cat %f" filename.root | lpr
1830 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
1831 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
1832
1833 - callisto: fixed a bug in the recognition of the calibration bit
1834 pattern. Concerns only intensity calibration. (The strength of the
1835 intensity has been updated in some cases)
1836
1837 - callisto: add a filter against PIN Diode events when running over
1838 calibration runs since some of the recent calibration runs have
1839 been taken with Pin Diode.
1840
1841 - callisto: added support for the runs 39942, 39944, 44834, 39941,
1842 39943, 44833 in the calibration (MCalibColorSet)
1843
1844 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
1845 been set to 1e-18 in callisto_Dec04_Jan05.rc
1846
1847 - callisto: in callisto_Dec04Jan05.rc: set value for
1848 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
1849 statistics for the calculation of the mean pulse time
1850 of the cosmisc
1851
1852 - callisto: the charge limit in the calibration has been raised
1853 from 2.5 to 4.5
1854
1855 - callisto: new setup read from callisto.rc
1856 + MCalibCalcFromPast.fNumEventsDump
1857 + MHCalibrationChargeCam.NumHiGainSaturationLimit
1858 + MHCalibrationChargeCam.NumLoGainSaturationLimit
1859
1860 - callisto: MExtractTimeAndChargeSpline extractor:
1861 + The integration ranges were shifted by 0.2 FADC slices to the right.
1862 + unreliable handling of floating point values caused different
1863 results on different platform or with different compiler options:
1864 The new algorithm is numerically exact and more accurate because
1865 it doesn't calculate the integration position by multiple times
1866 adding the step-size (which results in numerical uncertanties
1867 exspecially if multiplied with large numbers)
1868 + A lot of fixes have been introduced which effects integrating the
1869 spline at the edges of the valid range. In this case any memory
1870 was randomly accessed. This behaviour can be tested replacing
1871 all MArrayF by TArrayF which perform a range check (but of course
1872 they are a lot slower)
1873 ! No result obtained with the Spline before can be trusted! Due to
1874 random memory access it might by completely random!
1875
1876 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
1877 + extraction range in the high gain to 4.
1878 + weights file to cosmics_weights46.dat
1879
1880 - callisto:
1881 + introduce the check for fluctuating arrival times.
1882 + set charge limit to from 2.5 to 4.5
1883 + introduce asymmetric exclusion due to "deviating number of phes":
1884 Default: -9.0 +4.5
1885 + make deviating number of phes unsuitable (see David's findings).
1886
1887 - callisto: fixed the display of unsuitable pixels. The old change
1888 to a real profile in MHCamera broke it.
1889
1890 - callisto: The cosmics filter is used in MJCalibration now
1891 independant of the pulser color (formaly it was used only for
1892 CT1-pulser data). The threshold of number of max empty pixels
1893 has been raised from 2% to 5% in MJCalibration. The maximum
1894 fraction of rejected event is 50% otherwise the calibration has
1895 failed. The filter now ignores unsuitable pixels.
1896 Setup the filter from callisto.rc using "ContCosmics"
1897 (see MFCosmics::ReadEnv)
1898
1899 - callisto: changed default for fgOffsetFromLogain back
1900 from -2.8 to -1.8 in digital filter.
1901
1902 - callisto: for the common extractors
1903 + MExtractFixedWindow
1904 * MExtractTimeAndChargeSlidingWindow
1905 * MExtractTimeAndChargeSpline
1906 * MExtractTimeAndChargeDigitalFilter
1907 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
1908 and fResolutionPerPheLoGain
1909
1910 - callisto: Updated the hi-/lo-gain intercalibration constants
1911 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
1912 hilocalib_df6.root
1913
1914 - callisto: The default lo-gain extraction window for the
1915 MExtractTimeAndChargeSlidingWindow extractor has been increased
1916 from 6 to 8 to take the stretch of the pusle into account
1917
1918 - callisto (!!!): fixed an important bug in the setting of the
1919 incoming pedestal pointer to the signal extractor extracting
1920 pedestals. This bug caused the pedestals not to be subtracted
1921 correctly in the calibration afterwards. The effect was about 10%
1922 too high conversion factors for the digital filter and the spline
1923 and more than 40% for the sliding window.
1924 The bug existed since end of February! (Markus G.)
1925
1926 - star: added muon support to star. A new tab "MHMuonPar" is
1927 displayed. The lower right plot is an estimate of the point spread
1928 function. A reference value is displayed. To get the real PSF
1929 you must compare with MC. The setup for the muon analysis
1930 is done in star.rc. More informations can be found in
1931 MHSingleMuon and MHCalibParCalc
1932
1933 - star: The weather data is now displayed in star
1934
1935 - star: MEventRateCalc handles the calculation of the event rate more
1936 accurate now in case of the start of a new run inside a sequence
1937
1938 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
1939 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
1940 changed only minimally
1941
1942 - ganymed: (MJCut and MJOptimize) now displayes the number of
1943 excess events versus size. The energy estimation is done in
1944 MJSpectrum (sponde)
1945
1946 - ganymed: got support for using other variables than Alpha, eg. Theta.
1947 Therefor you need a class deriving from MHAlpha which supports
1948 this variable (one is already existing: MHTheta, which is now the
1949 default in ganymed). It is setup through ganymed.rc
1950
1951 - added a full featured spectrum program (sponde) which reads
1952 ganymed output and monte carlos and compiles a spectrum
1953
1954
1955
1956 *** Version 0.9.1 (2005/04/14)
1957
1958 - Fix bug on the arrival time reconstruction when using Digital
1959 Filter (in some marginal cases (10%) times were reconstructed shifted
1960 by 0.2 slices)
1961
1962 - all executables now return 2 where in previous versions -1 has
1963 been returned (gave problems with shell-scripts)
1964
1965 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
1966 also done with a intercalibration input file
1967
1968 - a bug in the time fine adjustment of the digital filter has been fixed
1969
1970 - a lot of small fixes to calling TPad::Divide with a margin==0
1971
1972 - MStatusDisplay now shows the memory usage
1973
1974 - added a memory leak statistic after the eventloop
1975
1976 - MHadronness replaced by MParameterD
1977
1978 - MEnergyEst replaced by MParameterD
1979
1980 - wobble mode can now be switched on from the data-set
1981
1982 - switched on bad pixel detection for a pedestal level
1983 which is more than 5 times the variance
1984
1985 - Fixed default paths to be correct for the new data center
1986
1987 - Fixed handling of drive data. The pointing position in now
1988 copied to MPointingPos inside star for real and MC events
1989
1990 - made sure, that the sequences in a dataset are sorted by
1991 their number to ensure the correct synchronization
1992
1993 - added all resource files necessary to handle spline extraction
1994 of signal for the late 2004 and the early 2005 data
1995
1996 - update the reference lines for the december data
1997
1998 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
1999 This is important for the Dec. and Jan. data where the calibration
2000 pulse position changes much.
2001
2002 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2003 filter. This corrects only an defective extraction of the MC at
2004 low-gain signals lower than 90 phes.
2005
2006 - fixed some slowdown in calibrating data with interleaved events from
2007 Jan and Dec. As a workaround made the pretty palette the default.
2008 The inverse Deep Blue Sea has a bug which slows down long calibration
2009 runs a lot.
2010
2011 - implemented new values from new starguider report as defined
2012 in TDAS00-07 V7.1 (eg SkyBrighness)
2013
2014 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2015 in starguider report (If you merpp the same reports with this version
2016 you'll get the correct units (arcmin) but a different result
2017 than with old versions (wrong units))
2018
2019 - Now the status display can also write PNG, JPEG and XPM (other file
2020 formats are still unsupported by root)
2021
2022 - added a lot of scripts and macros in directory datacenter used
2023 for automatic processing
2024
2025
2026
2027 *** Version 0.9 (2005/03/23)
2028
2029 - Calibration is now done autmatically into photo-electrons like
2030 decided by the Collaboration Board
2031
2032 - Reference lines in the display can be read from resource file
2033
2034 - Interlaced calibration events can be handled by callisto
2035
2036 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2037 and applied in callisto.
2038
2039 - class MJCalibTest can be called by callisto
2040
2041 - callisto can now run with three data types: rawdata, rootdata, MC
2042
2043 - added two classes mreport/MReportStarguider.cc and
2044 mreport/MReportStarguider.h for implementing starguider-data
2045
2046 - the output of merpp-update now contains starguider information:
2047 MReportStarguider and MTimeStarguider
2048
2049 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2050 values were lower than they should. This was more visible for high
2051 energy (Size) events.
2052
2053 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2054
2055 - added a new loop to callisto to support the correct extraction of
2056 the pedestal and pedestal rms through the signal extractor
2057
2058 - added class to perform fourier tranformation of a hexagonal structure
2059 (MHexagonalFT)
2060
2061 - added class to perform fourier tranformation of a hexagonal structure
2062 in a tasklist (MHexagonalFTCalc) example: hft.C
2063
2064 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2065 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2066 small pixels, example: extendcam.C
2067
2068 - added possibility to write data to memory (TTree) using MWriteRootFile
2069
2070 - added possibility to read a TTree stored only in memory by MReadTree
2071
2072 - new classes to deal with the interleaved calibration events:
2073 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2074
2075 - implemented filters to callisto to skip calibration events
2076
2077 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2078 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2079 the slices by statistics
2080 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2081 signal extractor without randomization
2082 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2083 with the signal extractor with randomization (extraction window is
2084 randomly fixed)
2085 The three kind of pedestal is not yet implemented (for speed reasons) as
2086 long as nobody really needs it:
2087 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2088 extracted with the signal extractor with randomization
2089
2090 - callisto now finds the pulse position in the data automatically
2091
2092 - implemented data reduction in calibrated data by reducing the precision
2093 of the stored floating point values (pedestal, rms and signal) to
2094 roughly 0.5%
2095
2096 - fixed showplot to make file format conversion (eg. converting a
2097 status display stored in a root file into a postscript file) in
2098 batch mode possible:
2099 showplot -b --save-as-ps[=outfile.ps] infile.root
2100
2101 - Allow class names as part of filter rules, eg
2102 (MFSupercuts) && (MHillas.fSize>100)
2103
2104 - fixed a lot of stuff to allow all programs to process MonteCarlo
2105 camera files.
2106
2107 - enhanced possibility to debug reading of resource file
2108
2109 - MDataChain should handle priorities of operator more
2110 accurate now
2111
2112 - completely revised the container in which the signal is stored
2113 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2114 * the new implementation is faster and
2115 * needs less storage space
2116
2117 - FIRST version which can process Monte Carlos through the
2118 whole chain of programs (callisto, star, etc)
2119
2120 - implemented new image parameters for the border length of
2121 the shower image (MNewImagePar2)
2122
2123 - implemented wobble-mode in ganymed
2124
2125 - new class (MJOptimize) taking care of all optimization processes
2126
2127
2128
2129 *** Version 0.8.6 (2004/10/05)
2130
2131 - New combined signal and time extractor
2132 MExtractTimeAndChargeDigitalFilter
2133
2134 - The Report for the trigger section in the CC run summary has been
2135 updated, and now the IPRs (Individual Pixel Rates) are available.
2136
2137 - new macros for database interaction: filldotrun.C, filldotrbk.C
2138
2139 - added new program which can convert colored output which was redirected
2140 into a file back into colored text (for example to display it with
2141 more): showlog
2142
2143 - added new program to display an MStatusArray of plots (stored with
2144 MStatusDisplay) from a file: showplot
2145
2146 - Added support for Sequences (MSequence). Sequences are blocks of run
2147 files containing the same calibration and belonging to the same
2148 source
2149
2150 - Added a new task (MTaskEnv) which can be used in setup files to switch
2151 between different tasks (for example to choose a signal extractor)
2152
2153 - Implemented automatic file splitting in MWriteRootFile
2154
2155 - After image cleaning an island index is assigned to all used pixels.
2156 The index corresponds to the order of the islands in size.
2157
2158 - added a cleaning which takes signal height _and_ arrival time into
2159 account: probability cleaning (for more details see MImgCleanStd)
2160
2161 - added a cleaning which takes takes the absolute number of photons
2162 times the area ratio as cleaning level
2163 (for more details see MImgCleanStd)
2164
2165 - Changed calculation of image parameters such, that it can be done
2166 for all used pixels or the pixels with a defined island index only
2167
2168 - implemented new image parameters displaying the number of islands,
2169 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2170
2171 - event display in executable changed to support also calibrated files
2172 (done with MJCalibrateSignal)
2173
2174 - added program doing the calibration and the signal extraction
2175 and signal calibration: callisto Most part of the setup is done
2176 by a resource file: callisto.rc
2177
2178 - implemented support for pixels with negative IDs (Raw file format
2179 version 4)
2180
2181 - implemented an new option in merpp (--auto-time) to get the time
2182 range for cc and/or caco data from the run header of the raw data
2183
2184 - New star-program (star and MJStar). Taking calibrated data from
2185 callisto/MJCalibrateSignal as input. The setup is done through
2186 a resource file: star.rc
2187
2188 - Added possibility to setup the eventloop in the mars-executable
2189 Camera Display by a resource file: mars.rc
2190
2191 - The the mars-executable Camera Display can now also read
2192 calibrated data files written by callisto/MJCalibrateSignal
2193
2194 - Added a new class which can calculate the source position in
2195 the camera from a pointing model known to be correct and
2196 the pointing model used for observations (MSrcPosFromModel)
2197
2198 - added a new version of the class calculating the effective on-time
2199 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2200 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2201 MHTimeDiffTheta.
2202
2203 - added the possibility to count how often a signal is above (or
2204 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2205 can replace MHTriggerLvl0)
2206
2207 - added ore convinient ways to set the axis-titles of your histograms
2208 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2209 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2210
2211
2212
2213 *** Version 0.8.5 (2004/08/06)
2214
2215 - new Signal Extractors: MExtractFixedWindowSpline
2216 and MExtractAmplitudeSpline
2217
2218 - implementes interleave in merpp to be able to merpp parts of a file
2219
2220 - implemented force-functionality to merpp
2221
2222 - star display to display star catalogs (MAstroCatalog)
2223
2224 - star display to 'mirror' stars to the camera (MAstroCamera)
2225
2226 - implemented a new cleaning option which allows cleaning scaled with
2227 the real ratio of the rms depending on the pixel size, not only the
2228 square root of the pixelsize (MImgCleanStd, MCameraData)
2229
2230 - removed obsolete MBlind* classes
2231
2232 - Signal extractor taking the AB flag into account implemented (this makes
2233 an odd number of slices for signal extraction possible
2234 (MExtractSignalABcorr)
2235
2236 - implemented a class extracting the pedestal from the raw-data (events)
2237 itself using empty lo-gain (MpedCalcFromLoGain)
2238
2239 - Added mean values to MPedPhotCam
2240
2241 - Added Makefile for Darwin (this OS is NOT officially supported!)
2242
2243
2244
2245 *** Version 0.8.4 (2004/04/19)
2246
2247 - new fast arrival time extractor using cubic splines:
2248 MExtractTimeFastSpline
2249
2250 - implementes multi-argument support in MDataChain
2251 ("pow(a, b)")
2252
2253 - implemented double reference support in MDataChain
2254 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2255
2256 - added support in MF for expressiond like
2257 "MHillas.fWidth<2*<MHillas.fLength"
2258
2259 - MDataChain is now able to support variables like [0], [1], ...
2260 which can be used in fit functions as parameters. The interface
2261 is implemented through the new virtual function
2262 MParContainer::SetVariables
2263
2264 - added new class MArrivalTimeCam/MArrivalTimePix:
2265 Storage containers to hold the ArrivalTime of the camera/pixel
2266
2267 - added new classes for the calibration of relative arrival times:
2268 MCalibrationRelTimePix and MCalibrationRelTimeCam
2269
2270 - added new classes to extract the signal of the blind pixel and the
2271 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2272
2273 - added new classes for the bad-pixels treatment (MBadPixels*)
2274 which are more powerfull than the old ones (MBlindPixel*)
2275 and will replace them.
2276
2277 - added filter against cosmics: MFCosmics
2278
2279 - added new class MArrivalTimeCalc2:
2280 Calculates the arrival time as the signal weighted mean of the time
2281 slices in the maximum window
2282
2283 - added a new macro call pointspreadfucntion.C that fits with a 2D
2284 gaussian the DC spot for an star. It gives you the RMS of
2285 the PSF and the center of the star, very useful for misspointing
2286 studies.
2287
2288 - added support for multi-telescope camera files. Added classes
2289 MStereoCalc and MStereoPar, classes to calculate and store shower
2290 parameters calculated from the data of two telescopes, for the MC
2291 studies regarding the MAGIC clone.
2292
2293 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2294 MC data calibrated in photons instead of ADC counts.
2295
2296 - added three macros to show the calibration and analysis chain of
2297 MC data. The macro starmc.C does both calibration and analysis, producing
2298 an output containing Hillas parameters for each event. The macro
2299 mccalibrate.C does just the calibration and writes out a file containing
2300 pixel information in photons instead of FADC data. The macro starmc2.C
2301 reads in such a file and produces an output with Hillas parameters.
2302
2303 - added MPedPhotCalc to compute pedestals in units of photons, see
2304 macro pedphotcalc.C
2305
2306 - added all class to perform the calibration, see macro calibration.C
2307
2308 - added class MFFT to perform Fast Fourier Transforms
2309
2310 - added class MSimulatedAnnealing to perform simulated annealing
2311 minimizations
2312
2313 - added new macro bootcampstandardanalysis.C which holds the skeleton
2314 of the analysis chain discussed in the december bootcamp.
2315
2316 - added support for DAQ raw data file format V2
2317
2318 - implemented an arbitrary time stamp for the events from raw-data
2319 files with file version<3. It is calculated from the run number,
2320 the date of start and the FADC clock tick from the first module
2321
2322 - implemented the correct decoding of the event time-stamp
2323 coming from the DAQ for raw-data files with file-version>2
2324
2325 - added a new classes storing the pedestals in units of photons:
2326 MPedPhotPix, MPedPhotCam
2327
2328 - added support for DC current files from the camera control
2329
2330 - added support for start- and stop-time when merpping report files
2331
2332 - added MReportCC storing the weather data from the CC-REPORT
2333
2334 - added class to fill trainings and test matrices (MTFillMatrix)
2335
2336 - added a filter performing a software trigger (MFSoftwareTrigger)
2337
2338 - Added classes to perform parts of the standard analysis (Jobs):
2339 + MJPedestals
2340 + MJCalibration
2341 + MJExtractSignal
2342 Note: All of them are preliminary!
2343
2344 - Added Iterator to iterate over files giving only the run-number
2345
2346 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2347 the evolution of a sector vs time
2348
2349
2350
2351 *** Version 0.8.3 (2003/12/05)
2352
2353 - adapted Random Forest classes to allow the use with MC
2354 multi-telescope files which can be produced with the coming
2355 camera version 0.7.
2356
2357 - added classes to read and interprete central control report files
2358 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2359
2360 - enhanced merpp (the executable) to support .raw and .rep files.
2361
2362 - added classes for light calibration (MCalibration* and
2363 MHCalibration*) by Markus Gaug. Further work has to be and will
2364 be done soon.
2365
2366 - Added a preliminary 'synchronizer' (MReadReports) which will
2367 replace MReadMarsFile as soon as it is finished.
2368
2369 - Added a tutorial macro demonstrating how report files are merpped
2370 and how they can be read from the root file in the correct order
2371 of time (readrep.C)
2372
2373 - Added a generalized histogram (similar to MH3) called MVsTime
2374 which allows to plot variables (or rules - MDataChain - of
2375 variables) vs time. For an example have a look at tempvstime.C.
2376
2377 - Changed the name of the event trees:
2378 + Events --> Events
2379 + PedEvents --> Pedestals
2380 + CalEvents --> Calibration
2381
2382 - changed name of MTime in the event trees from MRawEvtTime to MTime
2383
2384 - added displaying the sector indices to the mars event display
2385
2386 - Magic Online Analysis (MOnA) implemented in a first version
2387 (see mona.cc, MOnlineDump and MOnlineDisplay)
2388
2389 - added classes to calculate event rate
2390 (preliminary: MEventRateCalc, MEventRate)
2391
2392 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2393
2394 - added classes dealing with the telescope pointing position (MPointing*)
2395
2396 - implemented the 'final' Mars time stamp based on some experiences with
2397 the new 'Synchonizer'
2398
2399
2400
2401 *** Version 0.8.2 (2003/11/10)
2402
2403 - accelerated standard analysis by a factor of 6-8 ...
2404 + doing precalculations in MGeomCam for the pixel area ratio
2405 + creating a look up table for the single pixels in MCerPhotEvt
2406
2407 - added task to calculates weights in case you want to 'change'
2408 the energy spectrum of a monte carlo file
2409 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2410
2411 - added a new executable star which implements the
2412 star.C macro as precompiled executable. Currently a flexible
2413 setup is not possible, but a 'input card' setup will follow.
2414
2415 - Starting to implement Multi-Telescope-Support based on the
2416 upcomming camera version 0.7. The base for a general support
2417 is implemented and the star-functionality is proven to work.
2418
2419 - Replaced Event-Display in and Camera-Display in the Mars GUI
2420 executable by a more convinient display base on MStatusDisplay.
2421
2422 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2423
2424
2425
2426 *** Version 0.8.1 (2003/10/20)
2427
2428 - added signal subtraction for pure on data by means of fitting
2429 the background in the off region or by performing a combined
2430 signal/background fit. Provides necessary histograms for
2431 obtaining energy spectra and a light curve.
2432
2433 - added classes to perform and study the selection of the
2434 2nd Level Trigger on MC data (example in triglvl2.C macro)
2435
2436 - added pedestal calculation
2437
2438 - implemented "democratic cleaning" (tail cut value proportional
2439 to pixel area) according to Wolfgang's suggestion.
2440
2441 - added Sigmabar treatment (calculation and basic histogramming)
2442
2443 - added basic routines to apply padding
2444
2445 - added first implementation of MARS-based source visibility plotter
2446 (needs to be linked against slalib, preliminary version)
2447
2448 - enhanced functionality of data chains: random numbers, conversion
2449 functions and access to MHMatrix objects
2450
2451 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2452 numbers under certain circumstances (runs with 0 events included)
2453
2454 - fixed a bug in the general filter MF (didn't work on some systems
2455 at all)
2456
2457 - fixed a bug in chaining files, which caused the analysis to crash or
2458 ignore files
2459
2460 - implemented more geometry classes describing the parameters used
2461 to simulate the PMT camera
2462
2463 - added new Monte Carlo classes containing the setup of the different
2464 programs in the MC chain.
2465
2466 - added a (preliminary) general task to evaluate chi-square of a given
2467 parameter in an eventloop.
2468
2469 - first implementation of a container describing the observatory
2470 location (Long, Lat, etc)
2471
2472 - added Random Forest - method for g/h-separation
2473
2474 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2475 (this means, that it is compiling, but not yet fully tested)
2476
2477 - added a new status display which can show the present status
2478 of histograms while an eventloop is running (MStatusDisplay,
2479 an example can be found at status.C)
2480
2481 - reorganized directories:
2482 classes describing the image --> mimage
2483 classes containing Monte Carlo Histograms --> mhistmc
2484 classes for Random Forest method --> mranforest
2485
2486 - added (event-)weights to fill histograms
2487
2488 - colors in logging output to screen
2489
2490 - changes to the Image Parameter declaration:
2491 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2492 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2493 + MHillasExt now derives from MParContainer instead of MHillas
2494 --> Files written with the old definition are more or less unreadable
2495
2496 - reading of reflector files
2497
2498 - display data from reflector files in the camera
2499
2500 - implemented currents (and display them in the camera)
2501
2502 - logarithmic scale in camera
2503
2504 - added class to iterate through directory contents (MDirIter)
2505
2506
2507
2508 *** Version 0.8 (2002/11/18)
2509
2510 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2511
2512 - corrected 48(!) wrong entries in the Next Neighbor table of the
2513 Magic Camera (all in the inner part of the outer ring, mostly
2514 missing a single NN)
2515
2516 - Fixed a bug in the table describing the Next Neighbours of the
2517 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2518 have any neighbour)
2519
2520 - changed trigrate.C: now it calculates the pure NSB triggers from
2521 a camera file (generated with no showers), so there is no need
2522 to introduce them by hand in the BgR array (for more details
2523 please ask Abelardo)
2524
2525 - added MHHadronness (and MHadronness) as a general facility to evaluate
2526 the quality of a gamma-hadron seperation method
2527
2528 - changed MWriteAsciiFile to accept rules (MDataChain)
2529
2530 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2531 must be replaced by calles to MWriteAsciiFile::AddColumn and
2532 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2533 changed.
2534
2535 - Implemented generalized event-matrices (one row per event)
2536 (MHMatrix)
2537
2538 - implemented the one dimensional composite probabilities
2539 (MHCompProb, MCompProbCalc, comprob.C)
2540
2541 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2542 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2543
2544 - Added a camera display displaying the pixel numbers to the
2545 event display gui.
2546
2547 - Added Monte Carlo Informations to event display gui
2548
2549 - Changed the camera display to display the pixel numbering
2550
2551 - Added three buttons to the camera display to change the palette
2552
2553 - Added the number of used and core pixels after image cleaning
2554 to MHillas
2555
2556 - Changed the algorithm used in MHillas according to TDAS 02-03
2557
2558 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2559
2560 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2561
2562 - Added fCosDeltaAlpha to MHillasSrc
2563
2564 - The numbers of photons used to calculate fConc and fConc1 in
2565 MHillasExt are now scaled with the pixel size, so that one get
2566 a four times smaller value for the bigger pixels in the outer ring.
2567
2568 - added new task to smooth the camera contents (MCameraSmooth)
2569
2570 - added possibility to use interpolated pixel values for blind pixels
2571 instead of removing it completely from the analysis
2572
2573 - Implemented the possibility to save the whole eventloop with
2574 its setup to a file. This information can be read and from
2575 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2576 and MEvtLoop::MakeMacro. If you find something not working, please
2577 report - this stuff is still in a beta phase.
2578
2579 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2580 file having crab starfield, but also for all following files - fixed
2581
2582 - MTaskList::PrintStatistics can now be instructud to print also the
2583 title, too: use PrintStatistics(0, kTRUE)
2584
2585 - Changed the image cleaning so that pixels with to many 'used'
2586 neighbors are left used (to get rid of 'holes' in events)
2587
2588 - Introduced more output to the camera displays
2589
2590 - Added an array of histograms (eg one hist per run), MHArray
2591
2592 - Added a _preliminary_ version of the reader for CT1 PreProc files
2593 (MCT1ReadPreProc)
2594
2595 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2596 (thanks to Raquel)
2597
2598 - added the first energy estimator (MEnergyEstParam, estimate.C,
2599 estfit.C) using a parametrization
2600
2601 - Added some new Monte Carlo paremeter containers used to store
2602 setup information from the MC chain (MMcConfigRunHeader,
2603 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2604
2605
2606
2607 *** Version 0.7 (2002/04/30)
2608
2609 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2610 the pedestal mean value was saved incorrectly. For files from
2611 this versions we substract 0.5 from the pedestal mean.
2612 WARNING: This may effect your results, so don't wonder...
2613
2614 - First implementation of an algorithm using only triggered events
2615 for the collection area calculation
2616
2617 - Ascii Output can now also be used for parameter containers which
2618 doesn't overload MParCointainer::AsciiWrite
2619
2620 - The Ascii Output is now also capable of writing single data members
2621 of one container
2622
2623 - You are now able to change the order of the values written to the
2624 ascii file
2625
2626 - You can now specify a conversion factor for each data member written
2627 to an ascii file. This may be usefull to change the units of the
2628 data member (eg. degrees instead of millimeters in case of the
2629 hillas parameters)
2630
2631 - Replaced old MHillas by a new structure which allows you to extend
2632 the parameters stored in MHillas very easily:
2633 see MHillas and MHillasExt
2634
2635 - Added classes to handle source dependancy of image parameters:
2636 see MHillasSrc
2637
2638 - Added container (MBinning) to have a standard input for the binning
2639 in different histograms (eg. the Energy bins should be the same in
2640 all histograms)
2641
2642 - Changed Hillas histograms from mm to deg
2643
2644 - Added the flexible binning to the hillas histograms
2645
2646 - Added a filter for the alpha parameter (MFAlpha)
2647
2648 - It is now possible to write single data members of a class object to
2649 an output stream instead of the whole container only
2650
2651 - Added a generalized filter for a data member:
2652 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2653
2654 - Added a generalized Filter parser for more difficult filter rules
2655 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2656
2657 - Added new Monte Carlo histograms:
2658 MHMcEnergyImpact and MHMcEfficiency
2659
2660 - Added many new histograms needed for the flux calculation.
2661
2662 - Added a generalized histograms which can fill and show up to three
2663 data members in either a one-, two- or three-dimensional histogram, eg:
2664 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2665
2666 - Added:
2667 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2668 * calculation of <Theta> as a function of time (MHThetabarTime)
2669 they are needed in the flux calculation in
2670 order to select for a given bin in Theta (or time) the appropriate
2671 effective collection area, which is assumed to be given as a function
2672 of Theta and the true energy
2673
2674 - Added calculation of the migration matrix in the energy
2675 (MHMcEnergyMigration):
2676 the migration matrix describes the migration from the true (E_true)
2677 to the estimated energy (E_est); it is needed to determine the
2678 distribution of E_true from the measured distribution of E_est
2679 by unfolding
2680
2681 - changed the color palette in the camera display to DeapSea.
2682
2683
2684
2685 *** Version 0.6 (2002/01/15)
2686
2687 - Introduce the option of disable pixels (MBlindPixels and
2688 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2689 able to deal with Star Field NSB.
2690
2691 - Fixed a bug in the pedestals substraction
2692
2693 - Introduced verbosity levels
2694
2695 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2696
2697 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2698 work correctly (thanks to Abelardo)
2699
2700 - Introduced correct treatment of the diffuse Night Sky Background
2701 and NSB (MMcPedestalNSB)
2702
2703 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2704
2705 - Introduced MMcRunHeaders which contains monte carlo run informations
2706
2707 - Added a 'Print'-Task (MPrint) which calls the Print function
2708 of a parameter container for each event
2709
2710 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
2711
2712 - changes to be more efficient with root 3.02/06
2713
2714 - root 3.02/06 fixes:
2715 + the memory leak when reading MRawEvtData
2716 + loosing more time than necessary to update the progress bar
2717
2718 - MWriteAsciiFile is now capable of writing more than one container
2719 in a line. For example: To be able to write Monte Carlo and
2720 Hillas values (energy and alpha) in one line.
2721
2722
2723
2724 *** Version 0.5 (2001/11/06)
2725
2726 - Added new GUI functionality (Analysis)
2727
2728 - Added a camera display to be able to display events in the camera
2729 together with the calculated hillas ellipse
2730
2731 - Added a 'Clone'-Task (MClone) which can clone a parameter container
2732 object at any state of the analysis, so that the output are several
2733 states
2734
2735 - Fixed a bug in the collection area error calculation
2736 (Thanks to Ciro and Abelardo)
2737
2738 - Fixed a bug which causes merpp to crash in some environments
2739
2740 - Implemented auto enabling scheme for Branches to speed up reading
2741 a lot (see MReadTree and MTask)
2742
2743 - Fixed a bug in the Histogram classes which caused histograms to
2744 be written to a file by MWriteRootFile without request
2745
2746 - changed the object I/O from the old stylish root I/O to the new
2747 'auto evolution scheme' This was done only for classes which are not
2748 yet used in Monte Carlo files, so that these files are still readable.
2749
2750 - Added support for a progress bar in MEvtLoop and MReadTree
2751 (see the Analysis Window in Mars for an example)
2752
2753 - Fixed a bug in the package creation which disturbed the conversion
2754 between a mars version unpacked from a tar file and the repository.
2755
2756 - Changed the code to writer merpped (converted into root format)
2757 raw files, to get faster (around 10%)
2758
2759
2760
2761 *** Version 0.4 (2001/09/20)
2762
2763 - This release is made to compile on a root version >= 3.00
2764
2765 - Fixed a bug which causes MReadTree to read the first file only
2766
2767 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
2768
2769 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
2770
2771 - Added a task to write several container to a root file (MWriteRootFile)
2772
2773 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
2774
2775 - Added calculation of the collection area (MMcCollectionAreaCalc)
2776
2777 - fixed some bugs in the Hillas calculation
2778
2779 - added filters to be able to control the task execution dependent on
2780 a parameter (for example: the number of level 1 triggers in a MC-file)
2781
2782
2783
2784 *** Version 0.3 (2001/04/23)
2785
2786 - Many demo macros added
2787
2788 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
2789
2790 - Hillas Calculation added
2791
2792 - Standard image cleaning available
2793
2794 - MReadTree is now able to handle more than one file
2795 (Remark: of the same structure)
2796
2797 - Now we are able to display events in a first version of the
2798 Camera event display. To do this we must run the macro
2799 "macros/readCT1.C" to read data from CT1.
2800
2801
2802
2803 *** Version 0.2 (2001/01/24)
2804
2805 - First Implementation of a Gui to read the raw data. Start the
2806 gui with the command mars.
2807
2808
2809
2810 *** Version 0.1 (2000/12/20)
2811
2812 - First official release 0.1
2813
2814 - Changes:
2815
2816 + changed calling style of MRawPixelIterator from do...while to
2817 while-loop
Note: See TracBrowser for help on using the repository browser.