source: trunk/MagicSoft/Mars/NEWS@ 9274

Last change on this file since 9274 was 9274, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 127.6 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * This release doesn't contain a major change which is expected to
8 change your results. Nevertheless there are small changes to
9 the calibration which can effect at least the first few hundred
10 events in any (mainly MUX and even more SUM) sequence a little bit.
11 So it is recommended although not necessary to reset your sequences
12 in the database before further processing.
13
14 ;NEW
15
16 * A first implementation of a Monte Carlo simulation program
17 (ceres - Camera Electronics and REflector Simulation) has been
18 implemented. It can simulate a full telescope already including
19 a complete reflector simulation and a flexible trigger and readout
20 simulation. Currently, no perfect setup is implemented and
21 especially the output of the program (data structure) should
22 be considered alpha state. Also the user interface is not yet
23 ready.
24
25 ;general
26
27 * All command line options after -- are now interpreted as
28 arguments (usually everything which doesn't start with a minus)
29 rather than options (usually everything which starts with a
30 minus). This allows to use file names starting with a -
31
32 * In all resource files you can now initialize the random number
33 generator. For details see: MJob::InitRandomNumberGenerator
34
35 * added a new program called ''readcorsika''. It's purpose is (in analogy
36 to readraw and readdaq) to read a Corsika output file (for now
37 only cherenkov output is supported) and print its contents in a
38 human readable form. It can also write the contents of this file
39 into a root-file.
40
41 * The calculation of the maximum distance to the origin in a MGeomCam
42 has been improved (edges might be further away than the sides).
43 This is just a tiny change but it might change the appearance of
44 the radial profiles a little bit.
45
46 * The default binning of the center-of-gravity plot has slightly been
47 increased
48
49 ;Database
50
51 * Added informations about the DC currents (fMinCurrents, fMedCurrents
52 and fMaxCurrents). The values are retrieved from the plots showing
53 the average DC currents of all pixels versus time.
54
55 * Websites with tables have now the opportunity to remove lines
56 ('-' button at beginning of each line) and get all lines back
57 ('+' at top of the column)
58
59 * Websites: added option to query only sequences containing sumtrigger
60 events
61
62 * Websites: added option to group by date (year, month, night) for runs
63 and sequences and enabled that combining of different group-bys,
64 e.g. status, date and source is possible
65
66 ;automatic analyis
67
68 * Rewritten producing plots in the web.
69 New plots, namely the output of plotoptical.C (extinction curve from
70 KVA), plotstat.C (status of the automatic analysis (percentage of
71 processed, analysed data etc.)) and plotusage.C (statistics of the
72 condor usage in the data center) has been are available now next to the
73 plots of plotdb.C
74 Mean values from the plots (output of the macro) are provided in a
75 txt file now.
76 The creation of the plots for callisto, star and ganymed in the web is
77 now steered via database. Consequently the plots are faster and
78 reliable up-to-date.
79 For all plots, a new layout is available facilitating the browsing
80 through the plots and providing additional information on the
81 displayed values. (tabs.php) These plots are linked from the DB
82 websites and the wiki.
83
84 ;statusdisplay
85
86 * The ''Loop'' entry in the menu bar now contains an option to pause
87 the loop and to process single events.
88
89 ;merpp
90
91 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
92 instead of RunHeaders)
93
94 * Now allows to merpp files newer than 2008/09/03.
95
96 * Added fixes for wrong (wrong or double) run- and file-numbers
97 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
98
99 ;callisto
100
101 * Extracting the pulse position for the pulse position check events
102 with sum trigger were denied. This decreased the statistics
103 extremely and therefor the resulting puse position was calculated
104 quite weak. Now sum events pass the calculation if and only if they
105 have also a level 1 trigger.
106
107 * the extraction of pedestal events and pulse position from the
108 first data events is now more automatic and makes sure that
109 a more precise number of events is extracted independent of
110 the ratio with which pedestal events or events with signals
111 are contained in the data.
112
113 ;star
114
115 * For the calculation of the effective on time all sum-triggered events
116 were skipped. Now all Level1-triggeres events will pass. This might
117 result in a slight inaccuracy of the effective on time.
118
119 ;ganymed
120
121 * If the source position is more than 1deg away from the camera
122 center an error is raised now.
123
124 ;sponde
125
126 * Fixed a problem which causes the fitted spectral slope to be displayed
127 incorrectly. If you use MJSpectrum::FormFlux in your macros make
128 sure that the parameter 0 of your fit is negative.
129
130 * Added a histogram showing the read source position of your MCs
131
132
133
134== Version 2.1.1 (2008/08/04) ==
135
136 ;Database
137
138 * Added the median number of photo electrons from the calibration
139 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
140 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
141
142 * Added fTotOnTime, which is the on-time as given by the run-headers
143 (in contradiction to fAbsOnTime which comes from CC)
144
145 * Added new primaries for the new data structure (Magic II): for the
146 tables dealing with sequences (SequenceBuild Status, Sequences,
147 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
148 this is the telescope number (fTelescopeNumber) for the tables dealing
149 with runs (RunData and RunProcessStatus) this is in addition the file
150 number (fFileNumber)
151
152 * Added column fPriority to the status tables to be able to steer the order
153 in which the data is processed. As default the run, sequence and dataset
154 number are used.
155
156 ;automatic analyis
157
158 * Adapted scripts to the new data structure: They can handle now different
159 telescopes (getting the information as usual from the database).
160 The paths for Magic 2 are not yet implemented.
161
162 ;general
163
164 * should work now with root 5.20/00 (please note that root 5.20/00
165 we encounter crahses in the status display which are ot yet
166 understood)
167
168 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
169 instead of the base name of the file. This makes them easier to
170 access from the code
171
172 * Default Monte Carlo names in MSequence do not require the _E at
173 the end anymore
174
175 * where abrrevating a sequence file with a sequence number is possible
176 also "telescope:sequence" is now accepted, e.g.:
177 star 2:2000123 --out=output
178 see the programs' help for more details.
179
180 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
181 from the database. See the constructors for more details.
182
183 * MReadTree now supports friends
184
185 * MReadTree can now read also files not written by MARS and store
186 the data encapsulated in emulated MParContainers
187
188 * added a new starguider calibration valid since 15.1.08
189
190 ;showplot
191
192 * showplot can now read more than one file at once. This is especially
193 inetersting if reading files containing pure canvases
194
195 ;merpp
196
197 * we merpp the dc currents now also from the camera reports (they have
198 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
199
200 * In the automatic analysis we omit merpping of the currents from the
201 caco files and use the lower rate camera reports from the cc files
202 instead
203
204 * merpp has been redisigned to allow merpping of the cc-reports
205 of a whole sequence. This allows to design a very simple analysis:
206 mkdir output
207 ./callisto 100776 --out=output
208 ./merpp 100776 output
209 ./star 100776 --ind=output --out=output
210 Instead of the sequence number also sequence files are accepted.
211
212 * Implemented a fix for run-numbers between 1001348 and 1001396
213 which were incorrectly assigned by the cc.
214
215
216 ;callisto
217
218 * added a filter again which was was removed in the last release.
219 it removed the most brightest events. This should not change
220 any analysis result because these events are so bright that
221 they cannot be analysed anyway, but the bad-pixel plots doesn't
222 show outliers.
223
224 * updated muon calibration constants for the periods 51-57,
225 58-63 and 67-
226
227 ;star
228
229 * The camera currents are now displayed with the rate of the camera
230 reports instead of the caco reports
231
232 ;ganymed
233
234 * if mc camera files are new enough (>=8) the source position in the
235 camera is now calculated from the stored telscope and shower
236 orientation (Note, that this might not be suitable in all cases
237 depending on the aim of the study. These case still needs
238 implementation)
239
240
241
242== Version 2.1 (2008/06/18) ==
243
244 ;Database
245
246 * introduced average temperature and wind speed from star-files
247
248 * introduced average values from Pyrometer (mainly Cloudiness)
249
250 * introduced the ratio of accepted calibration events in the
251 calibration run
252
253 * introduced the average rates of the different trigger pattern,
254 e.g. the rate of pedestal and calibration events, from the signal-file
255
256 ;general
257
258 * fixed GroupBy options in plot*.C macros
259
260 * only display KVA points (not the Tuorla points) in plotoptical.C
261
262 * all programs now allow to add resources to the ones from the resource
263 file or overwrite them from the command line. This can be done like this
264 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
265 if something seems to be wrong you can debug what the program is doing
266 using the option --debug-env=3
267
268 * increased the diversity of debug levels. That also means that with -v3
269 you get now less output, i.e. only the output which is important for
270 an analysis. To get more output which helps for debugging try 4, 5 and 6.
271
272 * fixed a problem in the task synchronizing the reading of the reports
273 and the data stream. The effect was that in some circumstances the last
274 events of some trees could have been skipped. Since this is only a
275 very tiny part of the data no severe effect to your analysis results
276 is expected (an exception might be very short, i.e. singel runs,
277 datasets).
278
279 * Dataset file now allow to include the sequence file directly within
280 the dataset file and also allow to exclude single runs from the dataset.
281 (for more details see Class reference of MDataSet)
282
283 * Sequence files now allow for excluding runs from the analysis
284 (for more details see Class reference of MSequence)
285
286 * added code to process the sum-trigger flag
287
288 * the histogram classes MH3 and MHn now support profile histograms
289
290 * the histogram classes MH3 and MHn now support labels at the axis
291
292 * the Random Forest Train-classes (MJTRain*) now store the used datasets
293 in the output file
294
295 * the MFMagicCuts have a new option to allow a linear area cut (for
296 special studies)
297
298 * The liniking of the shared object is now done into a file defined
299 by 'mktemp'. This should be a local file system which accelerates
300 liniking a lot.
301
302 * The code has been prepared for compilation with root 5.18/00d
303
304 * The MHEnergyEst histogram now shows the distribution of
305 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
306 and (Eest-Emc)/Emc vs Emc.
307
308 * fixed mars (event display) for merpped raw-data and MC data
309
310 * adapted the synatx of sequence files to allow for the new run/file
311 scheme. For more details see class description of MSequence
312
313 ;showplot
314
315 * Added support for tiff files
316
317 * Added support for csv files (tables containing tab number,
318 name and title)
319
320 * Tabs now can have a title which is displayed in the postscript file
321
322 * When multiple file are written at once (e.g. pngs from a display)
323 it is now possible to use the tab name and or tab number in the
324 file name. For details see showplos's help.
325
326 ;merpp
327
328 * Implemented cc file version 2008-02-20/0
329
330 * Implemented cc file version 2008-05-19/0
331
332 * With new options merpping can be restricted (in addition to the
333 run-number) also by telescope and file number.
334 For details see "merpp --help"
335
336 * Implemented raw data format 11 (the most important change, except
337 from plenty of changes in the format definition, is the addition
338 of the file-number in the header) If nobody makes a mistake this
339 format should have the advantage that it is by definition forward
340 compatible, so old programs will be able to read newer formats.
341
342 * Added Pyrometer information to default output (stored in a new Tree
343 Pyrometer, needs a complete new merpp, i.e. new calibration)
344
345 * Merpping (also update) can now be restricted to one single report.
346 For example:
347 If you want to update an old file with Pyrometer information call
348 merpp --only=Pyrometer --update
349
350 ;callisto
351
352 * in the pedestal processing now at least 50 processed events are
353 required for succeeding.
354
355 * the signal and calib files now contain also the sequence information
356
357 * the two MPedestalCam in the calib file now have proper names
358 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
359
360 * Both pedestal cams now contain the number of events processed
361
362 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
363 i.e. for the extraction of the calibration pulses basically the average
364 over all events of the first slice instead of all slices was used.
365 Since pedestal and calibration constants are continously recalculated
366 this only effected the very first events of every sequence.
367
368 * For the extraction of the position of the maximum sample now the
369 extraction range is set automatically to the extraction window,
370 before the whole accessible range was used.
371
372 * If the number of samples in the events and the number of samples
373 in the run-header disagrees now an error is raised (this can
374 happen in not well simulated Monte Carlo files)
375
376 * In the case of MUX-data pedestal events with the lvl1 trigger flag
377 could survive into the pedestal calculation -- fixed.
378
379 * Tab "TrigPat" added showing the distribution of the trigger pattern
380 as found in the run-files (normalized with the run length)
381
382 * The selection of events from the trigger pattern has been improved.
383 If the trigger pattern is corrupted events won't pass anymore.
384
385 * Added a new command line option --dev-null to suppress output of
386 Y-files (this is useful for test cases)
387
388 * added a new tab "CalPos" showing the arrival time of extracted
389 interleaved calibration events
390
391 ;star
392
393 * the star file now contains also the sequence information
394
395 * Added a new command line option --dev-null to suppress output of
396 I-files (this is useful for test cases)
397
398 * Tab "Rate" added showing the distribution of the trigger pattern
399 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
400 the Y-files (normalized with the run length)
401
402 * The effective on-time calculation doesn't use events with only
403 sum-trigger anymore
404
405 * The data in the MHWeather tab has been reorganized. The never
406 working solar radiation has been removed and the data from
407 the pyrometer (cloudiness, air and sky temperature) is
408 displayed in addition.
409
410 ;ganymed/sponde
411
412 * Now data points are even shown correctly if they have error bars larger
413 than one sigma. Points with null or negative significances are omitted.
414
415 * DrawNicePlot now allows to set a projection range
416
417 * Updates pointing models. One is applied after the implementation
418 of the new LUTS in August, the other one is applied after the
419 next major change of the pointing model in October. Note that
420 these models are preliminary and give wrong results below Zd=65deg
421
422 ;sponde
423
424 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
425
426 * a new option "--force-runtime" is available. In case of very short
427 datasets (for light-curves) which are in the order of a few
428 minutes the calculated effective on-time is not very acurate because
429 it is quantizised in the order of a minute. Therefore you can switch
430 to using the real run-time instead (remakrt: this ignores any
431 dead-time!)
432
433 * a more analytical way is used to "fill" Monte Carlos into regions
434 of impact parameters which have not been simulated because the
435 trigger efficiency is assumed to be 0.
436
437 * estimated sensitivity curves for hi and lo zenith angles are shown
438 scaled to the correct observation time and collection area
439
440 * the Monte Carlo events after cuts are now written to the output file
441 if an output file given
442
443
444
445 *** Version 2.0 (2007/09/03)
446
447 - database: the position used for the pulse pos check was missing
448 in the callisto output and could thus not be filled into the DB.
449 Also the old values seemed not exactly the PulsePos used for
450 teh check.
451
452 - general: Resource file now allow an Include-Resource, i.e. you can
453 read a resource file with default settings, include it in your
454 resource file and overwrite the settings in your file. More than
455 one include file is allowed. Inclusions can be iterative.
456 Include: mydefaults.rc yourdefaults.rc
457 The resources in the first file have higher priority than the
458 second file.
459
460 - general: Now the output files (calib*.root, etc) also contain the
461 resource file (to check it open it in the TBrowser and choose Print()
462 from the context menu)
463
464 - general: Dataset files now allow to overwrite the default path
465 to search for sequence and data files. Note, that the program
466 option and individual resources will overwrite it. For example:
467 SequencePath: /magic/montecarlo/sequences
468 DataPath: /magic/montecarlo/star
469
470 - general: Fixed a problem with variables in MDataPhrase. It seems
471 that only optimdisp (didn't work) was effected.
472
473 - general: Some improvements to the optim and train processing. For
474 example the ststud window now got a proper title.
475
476 - general: The "Status Display: " was removed from the window title
477 within an Eventloop.
478
479 - general: added a new flexible histogram-class (MHn) which can be used
480 for example in testing after optimizations or training to produce
481 user defined histograms.
482
483 - general: The Random Forest now allows attaching an evaluation
484 function which is applied to its output. This allows to train
485 on whatever you like (eg. train on log10(energy), but return
486 energy)
487
488 - general: The Random Forest training of energy (trainenergy.c) and
489 disp (traindisp.C) has been improved by more graphical output to
490 judge the result.
491
492 - general: The training of energy (trainenergy.C) has been improved
493 a lot by training on a different quantity than energy. It gives
494 a result which is highly independant of the source spectrum
495 and shows lower bias than all other options.
496
497 - general: Dataset files are allowed to contain collections of
498 datasets. For more details see the class reference of MDataSet.
499
500 - general: The default WobbleMode in a datset file now (if not
501 overwritten) is "auto", i.e. wobble mode is set if the dataset
502 doesn't contain off-sequences.
503
504 - merpp: Merpp can read file format version 9 now. Please realize
505 that for file format version 9 the extraction range is different
506 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
507 the first and last 15 slices have been removed from all MUX data.
508
509 - mars: Similar to writing movies you can now select events which
510 should be displayed in your display. Therefore add the following
511 lines to your mars.rc:
512 MFEvtNumber.FileName: ganymed00223552.root
513 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
514 The input file can be a ganymed-file after (ganymed*.root) or
515 before (ganymed*-summary.root) file. For example to select all events
516 from your on sample after cuts (excluding the ThetaSq cut) use
517 MFEvtNumber.Selector: DataType.fVal>0.5
518 To show all events from your on-sample after quality cuts
519 use the summary file instead.
520
521 - mars: new ways to call mars are implemented. Instead
522 of calling
523 mars filename.root
524 you can now also use
525 mars sequence.txt
526 or
527 mars sequence.txt inputpath
528 or replace sequence.txt by the sequence number if the default
529 sequence file should be used.
530
531 - mars: The default size has been increased
532
533 - mars: There are two new heckboxes which allow to switch off
534 the calculated image parameters
535
536 - callisto: was broken for MCs... fixed.
537
538 - callisto: improved calculation of spline coefficients a lot. This
539 leads to a further improvement of the event rate calibrating MUX
540 data of about 15% (175evt/s instead of 150evt/s)
541
542 - callisto: finally the raw data we read is now real 16bit (with
543 10bit precision) for MUX data and not a stripped 8bit number
544 anymore. Due to scaling of the numbers (without precision loss
545 into an [0-256[ range, the final numbers for pedestal, pedestalrms
546 and extacted signal don't change. However, at all places where
547 raw data is directly accessed (eg. saturation and variation
548 limits in the signal- and pedestal-extraction) the numbers
549 refer still to the data's 16bit range.
550
551 - callisto: The maximum arrival time difference used in the bad
552 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
553 for both, old FADC and MUX-FADC, data.
554
555 - callisto: Be aware that callisto is now calibrating the arrival time
556 in nanoseconds rather than time slices. Also all following tasks
557 have been changed to assume ns units now. If you star data
558 calibrated with an older version it might be necessary to adapt
559 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
560 to obtain optimal results. The plot in the PulsePos tab
561 will now be in ns, too. This might also mean that the Muon
562 analysis in star might not work as perfect as expected as long
563 as old files read in.
564
565 - callisto: The calibration constants of earlier updates got lost
566 somehow. All constants have been updated.
567
568 - star: The PSF is now determined from the profile of the ArcWidth
569 instead of arcwidth/radius. The old way gave to much weight
570 to the bins with low statistics. The reference lines have been
571 updated.
572
573 - star: For speed reasons events suitable for the muon analysis
574 are now also preselected by fConcCOG<0.1 which seems to be a very
575 good preselector for muons.
576
577 - star: is now calculating a new timing parameter the Slope along
578 the major and minor axis of the shower. Therefore a numerical
579 solution of a line-fit is used. To use MHillasExt.fSlopeLong
580 and MHillasExt.fSlopeTrans don't forget to multiply it with
581 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
582
583 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
584 have been removed from MNewImagePar. They have never been good for
585 anything.
586
587 - star: Implemented a new recursive algorithm which is supposed to be
588 faster. Also implemented new cleaning oiptions, which are:
589 + CleanLevel0:
590 The cleaning level above single core pixels can be kept
591 + KeepIsolatedPixels:
592 Define whether single core pixels should be kept
593 + TimeLevel1:
594 The coincidence window in nanoseconds to single used neighbors
595 + TimeLevel2:
596 The coincidence window in nanoseconds to two used neighbors
597 + PostCleanType:
598 MOde in which a time dependent post cleaning should be applied
599 0: No post cleaning
600 1: Require for each used pixels at least one used neighbor
601 within a time-window of CleanLevel1
602 2: Require for each used pixels at least two used neighbor
603 within a time-window of CleanLevel2
604 3: Require first two and second one used neighbor
605 within a time-window of CleanLevel1 and fCleanLevel2
606 respectively
607 + RecoverIsolatedPixels:
608 - recoveres isolated core pixels if they have a used neighbor
609
610 - mars/star: The new default cleaning is:
611 + CleanLevel1: 6.0
612 + CleanLevel2: 3.0
613 + CleanTime1: 1.75
614 + CleanTime2: 1.75
615 + PostCleanType: 3
616
617 - star/ganymed: The old spark-cuts have been replaced by new ones.
618 These new spark cuts have been cross checked with the sequences
619 84720 (before splitter), 101041 (after splitter) and 223539 (new
620 FADCs). In all cases they seperate pretty well, but of course not
621 perfect. Monte Carlos have suggested to tighten the cuts a little
622 bit further at low sizes. This has been done.
623
624 - ganymed: IMPORTANT - The spark cuts have been changed to match
625 all available data more or less well. This might mean that for
626 YOUR data there are still sparks visible.
627 Whenever you do an analysis you have to make sure that NO sparks
628 survive your cuts!
629
630 - ganymed: The old hadronness and size cuts have gotten new indices
631 (10, 11). The old indices 8 and 9 now mean an additional condition
632 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
633 If you want to switch off this cut just move the line far away enough,
634 e.g. by setting c[9] to -500. Please update your ganymed.rc files
635 accordingly!
636 The unit of c[9] is deg. It is the dist at which your cut will
637 cross the slope==0. The unit of the slope is ns/deg. So if
638 you readin files calibrated with an older Mars-version you
639 have to adapt the default value for c[9] to the FADCs:
640 - Multiply by two for the MUX FADCs (run number > 200.000)
641 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
642 - Multiply by 42 for the meaning of life (run number = 200.000)
643
644 - ganymed: The old Cut0 is now called CutQ and is calculated before
645 the source position is caluclated. If you need a quality cut
646 including source dependant data (be very carefull with this!)
647 you have to use Cut0 instead.
648
649 - ganymed: now properly supports three off regions in wobble mode.
650 It will be the default from now on in ganymed_wobble.rc. To change
651 the number of off-regions use
652 NumOffSourcePositions: 1
653 in your ganymed.rc. Also by default no off-theta cut will be done
654 anymore so that you will get a background level higher than the
655 signal level in your ThetaSq plot for ThetaSq>0.2.
656 Due to this be carefull changing the scaling mode away from
657 "None". You will underestimate your signal if your scale interval
658 is not properly set.
659 (Rem: ThetaSqN is no longer needed)
660
661 - ganymed: is now storing the events of all (on- and off-)
662 source positions even in the case of more than one off-source
663 position. This should allow sponde to work properly and the
664 energy estimation is done correctly in all cases (without any
665 "nearest position" trick)
666
667 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
668 with a real pointing model for the starguider is done, calibrated
669 with more than thousand tpoints taken from this date on.
670
671 - ganymed: was broken for Wobble-MCs... fixed.
672
673 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
674 has changed. Note that your old ganymed.rc will be incompatible
675 with the new algorithms! Please check the ganymed.rc files and
676 the class description of MFMagicCuts for more information.
677 It is recommended at the moment to use identical Disp-Parametrizations
678 for on/off- and wobble-mode. If cuts are optimized only
679 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
680 should be optimized. All other values should be kept as they are.
681 If you want to do an anylsis without timing a parameters, you can
682 switch off the timing cuts by seeting parameter 7 to a very small
683 value (eg. -99). To remove the slope parameter from the disp
684 paremtrization set parameter 8 to 0.
685
686 - ganymed: The distribution of observation time versus zenith
687 angle is now shown for off- AND on-data.
688
689 - ganymed: The contents of the source position plot are no longer
690 averaged, thus a lot of (fake) events between the two wobble
691 positions have disappeared.
692
693 - ganymed: There is a new tab "CutT" it contains the VsSize plots
694 with the CutT, whihc is defined in ganymed.rc, applied. It
695 is resonable to use your theta-cut for it, to see if there is
696 something strange (sparks!) in your signal-region.
697
698 - ganymed: To choose a dataset from a collection in a dataset file
699 use the new command line option "--dataset=12345"
700
701 - optim, sponde: should now properly support three off-regions.
702 Just produce your ganymed summary files with three off-regions.
703 optim and sponde will automatically get all off events from
704 all off-regions from this file. Please do not forget to
705 set the scaling in optimwobble.C properly:
706 fit.SetScaleUser(1./3);
707 it is not yet read in automatically (will follow soon).
708 In the case of fixed Scale you can also use
709 cuts.SetThetaCut(MFMagicCuts::kOn);
710 no off-cut needed.
711 Be carefull in case of three off-regions when switching on
712 scale mode. Make sure that the scale interval is set correctly.
713
714 - sponde: sponde.rc and sponde_onoff.rc are now idetical
715
716 - sponde: the resouce files have been rewritten with a lot of
717 comments and a well working parametrization for an energy estimator
718
719 - sponde: In the estimated energy versus monte carlo energy plot the
720 contents where exchanged.... fixed.
721
722 - sponde: the so called "accurate"-mode has been removed. It didn't
723 give any improvement in accuracy, only decreased execution speed.
724
725 - sponde: the so called "simple"-mode has been removed. It didn't
726 give any improvement in simple.
727
728 - sponde: the so called "refill"-mode has been removed. It was anyhow
729 not implemented.
730
731 - sponde: now checks whether the theta distribution of your on-data
732 and the theta-distribution of your Monte Carlo sample (after
733 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
734 sample is incomplete) execution is stopped. Execution can be forced
735 using the new option --force-theta. Use this option with care!
736
737 - sponde: Proper collection areas can now be constructed also from
738 Monte Carlo samples generated with different maximum impact
739 parameters. Note that in previous version you neither got
740 a warning or failure, nor was there any obvious sign that the
741 collection area was overestimated due to usage of files with
742 different maximum impact parameters.
743
744 - sponde: If MC files with different lower energy limits are used
745 the primary MC spectrum is artificially completed down to the
746 lowest energy used at all. WARNING: that this gives correct
747 collection areas ONLY if none of the events in this region would
748 survive your cuts at all.
749
750 - sponde: the output file now contains more information about
751 the spectrum (eg. the full 2D collection area histogram).
752 Note, that this information can only be written to the file
753 if it is stored automatically via command line argument.
754 If you only store the status display from within the display
755 the information is lost.
756
757 - sponde: added a new tab "Disp". It shows the residual of the disp
758 (Disp-Dist) versus several parameters and it is meant to judge the
759 quality of the disp estimator. In the ideal case the residual is zero
760 and doesn't depend on any variable. The tab is displayed after
761 CutQ and Cut0.
762
763 - sponde: added a new tab "Energy". It shows the residual of the
764 energy (lg(estimated energy)-lg(monte carlo energy)) versus
765 several parameters and it is meant to judge the quality of the
766 energy estimator. In the ideal case the residual is zero
767 and doesn't depend on any variable. In reality even a good estimator
768 can show residuals versus Monte Carlo energy. The tab is displayed
769 after all cuts.
770
771 - sponde: added a new tab "EventDist" showing the unweighted real
772 absolute number of events of your sample after cuts. This tells
773 you how many events with this energy you had in your MC files.
774 The same information you get from the error bars of the weighted
775 histograms, but this is less intuitive.
776
777 - sponde: The spectrum plots now show the crab- and 1553-spectrum
778 for comparison. It is not meant to show these curves in
779 publications, they are only for production.
780
781 - sponde: The OriginalMC tree with the events produced by corsika
782 is now processed only once
783
784 - sponde: Finally fixed most annoying bug, which has effected the
785 last bin of the collection area. It was the problem that binnings
786 of root histograms are from 1 to n (included) but there was a C-like
787 loop in sponde from 0 to n (excluded). Now the loop also includes
788 correctly under- and overflow-bins. The worse thing with this is,
789 that for the events in the highest bin not only the bin-content
790 was wrong, but also the weights applied to these events, which could
791 in pricipal effect also other parts of the distribution (eg. due
792 to energy estimation). Fortunately it effected only a few events
793 in most cases.
794
795
796
797 *** Version 1.2 (2007/05/14)
798
799 - database: The database now has two new values Unsuitable50 and
800 Unsuitable01. They express the number of pixels which are
801 unsuitable for more than 50%, respectively more than 1%, of
802 all calibrated event. It is a more accurate number than the
803 previously used numbers, because they only take the first
804 calibration (ignoring the interleaved calibrations) into account.
805
806 - database: The database now has two other new values UnsuitableMax and
807 DeadMax. They express the maximum number of pixels which were
808 unsuitable, respectively dead, during the sequence. Because
809 of high pedestal rms (cars passing) a few events with very high
810 numbers of unsuitable pixels can happen. Not to suffer from this
811 effect we don't take the highest 0.1% of the numbers into account.
812
813 - general: fixed a bug which caused callisto and star to stop working
814 properly because the callisto output was currupted
815
816 - general: a script called scripts/makemovie has been added which
817 simplified the process of producing several movies from a single
818 sequence with different setup.
819
820 - callisto: Some more code cleanup. Started to remove old obsolete
821 code from cvs.
822
823 - callisto: The extraction of the pedestal with the extractor was
824 not random. It seems that extracting at one position is still biased
825 (for example in the first or last slices we could still suffer from
826 switching noise) Now it is completely random.
827
828 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
829 pedestal files) individual pixels could be skipped due to high
830 variations. This was already the case for the pedestal extraction
831 from the lo-gains since the beginning and properly handled
832 there, but was introduced in the extraction from the pedestal files
833 a while ago. To calculate the average value it was still divided
834 by the number of events procesed not by the number of summands
835 really summed. This let to a pedestal which was a tiny amount too
836 small (for a few piels in the order of 0.1%). This led to an slightly
837 positive offset of the randomly extracted pedestal for a few pixels.
838 I doubt that this has a big effect on the result, because the effect
839 on the individual numbers is quite small. Due to this it is suggested
840 that you rerun your calibration to make sure you are without any
841 avoidable bias.
842
843 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
844 the median rms of the absolute arrival time and expressed in significance
845 levels. This replaces the old meaning of an abolute upper limit. An
846 absolute upper limit doesn't make much sense, because in our data
847 all arrival times are shifted at the same time (in fact it might be
848 a shift of the artificial trigger w.r.t. to the light flash).
849
850 - callisto: Added a new tab "BadPixTm" which shows the time evolution
851 of the number of unsuitable pixels over the whole sequence. This
852 is usefull mainly to judge if an intermediate calibration had
853 problems.
854
855 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
856 of the number of dead pixels over the whole sequence. Dead pixels
857 in this context are unmapped pixels, i.e. pixels which could not
858 be interpolated, and thus are ignored in the further analysis.
859
860 - callisto: It is now possible to use the position of the maximum
861 of the spline as arrival time instead of the leading edge even
862 when using the integral for the signal. Therefor set the extraction
863 type to kIntegralRel ("IntegralRelative") and the relative height
864 ("HeightTm") to -1:
865 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
866 MJPedestalC1.ExtractSignal.HeightTm: -1
867
868
869
870
871 *** Version 1.1 (2007/04/27)
872
873 - general: The new class MGeomCamDwarf contains the camera geometry
874 for our prefered Dwarf camera and can be used to create general
875 geometries of roundish or hexagonal cameras.
876
877 - mars: The default cleaning is now abolute 8.5/4.0.
878
879 - mars: The resource file mars.rc now contains examples for MUX data
880
881 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
882 data containing only 10-bit information is still cooked down to
883 8-bit, by cutting away the lowest 8-bit.
884
885 - merpp: When reading raw data the data is now stored in a single
886 array. The lo-gain array is obsolete. The interface stays the same.
887
888 - callisto: To process the new MUX data use the resource file
889 callisto_mux.rc
890
891 - callisto: The -root and -raw options to read merpped raw data have
892 been removed
893
894 - callisto: If the -mc option is given the sequence-name can now be
895 replaced by the MC sequence number
896
897 - callisto: If the sequence file contains "MonteCarlo: Yes" the
898 -mc option can now be omitted
899
900 - callisto: Started further simplification by removing obsolete
901 dependancies on MCalibIntensity*Cams.
902
903 - callisto: removed unsused intensity calibration from MJCalibration
904 for further simplification
905
906 - callisto: for simplification removed references to
907 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
908 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
909 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
910 (this should at minimum change nothing at all, and at maximum
911 improve thing if these containers where somewhere not handled
912 properly)
913
914 - callisto: Added the option to write an event movie. Please use
915 this option with care (huge files) but exessively to understand
916 our events. For further documentation please refer to the
917 IACT wiki
918 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
919
920 - callisto: Improved binning for the pulse position check histogram
921
922 - callisto: The code calculating the pulse position checknow takes
923 the pedestal into account
924
925 - callisto: The arrival time is now stored with full precision this
926 helps to get rid of artefacts in histograms. For the signal this
927 is not necessray because it is displayed in log-scale anyhow
928
929 - callisto: Fixed a problem with internal exclusions. Pixels which
930 have once been marked as unsuitable didn't get the necessary
931 histograms filled anymore to be rechecked with each interleaved
932 calibration.
933
934 - callisto: The relative arrival time resolution (the rms of the
935 relative arrival time offset) is now checked against its
936 median and the median deviation, instead of the average
937 plus an absolute offset.
938
939 - callisto: The relative arrival time offset is now calculated
940 w.r.t. its median not w.r.t. to an artificial reference pixel.
941
942 - callisto: The relative time calibration now marks pixels with
943 outlaying offset as unsuitable
944
945 - callisto: The interleaved relative time calibration has been switched
946 on. The advantage is that pixels which are marked as outliers
947 now can recover. An improvement over time is not expected, because
948 the relative time calibration seems stable.
949
950 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
951 option can now be omitted.
952
953 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
954 or the option "-mc" is specified as default the monte carlo datacenter
955 paths (/magic/montecarlo/...) are used if not overwritten in the
956 dataset file.
957
958 - ganymed: The output files now contain run- and event-number for all
959 events, accessible as RunNumber.fVal and EvtNumber.fVal
960
961 - ganymed: Added a plot showing the source position in the camera also
962 for wobble mode
963
964 - ganymed: In addition to the existing task which can be setup to
965 be executed after Cut1 a final task called "EstimateEnergy"
966 has been added, executed before writing the final output
967 (ganymed00000000.root). The task setup in all three cases
968 can be choosen individually. (For all three(!) cases you
969 can for example choose MRanForestCalc. For examples see all
970 sponde*.rc and all ganymed*rc)
971
972 - ganymed: If a container "MEstimatedEnergy" is found in the
973 parameter list (eg. because it was setup by MEstimateEnergy)
974 it will be written to the output file.
975
976
977
978 *** Version 1.0 (2007/02/16)
979
980 - database: Website to plot values from the database has been added.
981
982 - database: The rate of spark events as found by star is now kept
983 and the rate after cleaning is now with spark events subtracted
984
985 - general: The changes to the interpretation of phrases lead to
986 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
987
988 - general: Added example files how you can create your own calendar
989 (eg. as christmas present) with Mars. Just run
990 root macros/tutorials/calendar.C
991
992 - general: Added a possibility to display grouped data in the plotdb.C
993 macro (and similar macros). This allows to plot hourly, nightly,
994 weekly, monthly and yearly averages.
995 For more details see the plotall function of the macro
996
997 - general: fixed the error display of the camera display. It showed
998 wrong results.
999
1000 - general: fixed a memory leak when reading many MStatusDisplays
1001
1002 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1003 between a spherical and a parabolic mirror
1004
1005 - callisto: We have a new pulse position check which takes the properties
1006 of the extractor automatically into account. So no need to set
1007 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1008 left is done. If possible the lo-gain extraction start and hi-gain
1009 extraction end is changed accordingly. If no proper extraction range
1010 can be set (hi-gain too much to the left) an error is raised.
1011
1012 - callisto: New swapped pixels have been found and corrected
1013
1014 - callisto: Redone the signal extraction this includes:
1015 + Unified the algorithms to extract the pedestal for all pedestal
1016 extractions done
1017 + Unification of hi- and lo-gain into one array
1018 + Unification of hi- and lo-gain extraction for Spline and
1019 Digital Filter (means now exactly the same algorithm is used,
1020 not a copy-and-pasted one)
1021 + Store pedestal subtracted data in a common place
1022 + Improved extraction algorithms. If the algorithms search a
1023 maximum but don't find one they don't return the maximum anymore
1024 + Improved the extraction such that a information for signal
1025 and time which is consistent is returned
1026 + replaced the numerical spline with a (not slower) analytical
1027 solution
1028 + Lowered the saturation limit from 250 to 245 to make sure that
1029 we are far away in all pixels from problems with the clock-noise
1030 + The start of the lo-gain extraction is calculated from the hi-gain
1031 arrival time. In case of saturation an estimation is used.
1032 + the hi-gain window was extended to slice 16. This allows extraction
1033 of very late pulses in single pixels or of huge hadron showers.
1034 + Now uses the lo-gain extraction range for pedestal extraction,
1035 not the hi-gain range in the lo-gain
1036
1037 - callisto: New hi-/lo-gain calibration constants have been produced
1038 for all periods from the statistic of the whole period. They are
1039 now used automatically depending on the periods. The old constants
1040 where deviation in avarega about 2%-3%. The constants are very
1041 stable from period to period (<<1%) except for exchanged channels.
1042 In a few cases the constants used so far were off by 1%-2% (maybe
1043 temperature effects?)
1044
1045 - callisto: To gain obsolete space we do not write the
1046 MPedestalFundamental anymore. Also calibration and bad pixel
1047 treatment is not done for it anymore because it has never been used.
1048
1049 - callisto: Fixed a bug in the seuqence handling which caused the
1050 light condition to be ignored
1051
1052 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1053 basically the same as "Cleaned" but the distribution devided into
1054 the events fullfilling a spark cut or being rejected by it.
1055 This cut can be changed from star.rc (see example inside) by
1056 the "SparkCut" directive
1057
1058 - star: Star displays now the average individual pixel-rate (IPR) versus
1059 time and the average discriminator threshold (DT) of all pixels.
1060
1061 - optim: fixed a problem with the optim-macros which was due to a bug
1062 in the new phrase parsing
1063
1064 - ganymed: To get a nice FalseSource plot (instead of the all-information
1065 debug plot displayed as a standard plot) use the context menu
1066 somewhere between the two upper plots, click on "DrawNicePlot"
1067 and enjoy the result. (It is the same context menu which contains
1068 the other options)
1069 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1070
1071 - ganymed/optim/train: The cut program, trainings- and optimization
1072 macros could run with less files found than expected from the
1073 sequence-files. No the execution is stopped in this case.
1074
1075 - ganymed: now stores the dataset in the output file with all information
1076 contained (as sequence number, sequence path, data path) so that the
1077 used dataset file can be recreated complete from the output
1078
1079 - sponde: now also allows the uasge of random forest
1080
1081 - sponde: added a plot showing the cut efficiency
1082
1083 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1084 errors (eg. effecting the collection area) because the errors of the
1085 two histograms were swapped in the calculation, which makes a difference
1086 in the case the histograms contains weighted events. Aditionally the
1087 totalarea was incorrectly taken into account, which results in too small
1088 errors, which makes a difference at low statistics were the errors
1089 or the collection area dominate.
1090
1091
1092
1093 *** Version 0.10.3 (2006/10/23)
1094
1095 - database: Implemented ObservationMode flag in websites.
1096
1097 - database: For sequences there is now also the stoptime available on the
1098 websites.
1099
1100 - database: Removed ManuallyChanged flag from sequence-info websites,
1101 as it is not needed anymore with the new sequence building algorithm.
1102
1103 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1104 Class for calculation of confidence intervals (upper limits).
1105 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1106 Please read the class instruction of TRolke for more information.
1107
1108 - general: The programs now return 0xfe if the requested resource file
1109 doesn't exist.
1110
1111 - general: Errors comming from root itself are now not output to
1112 stderr anymore but to our default (colored) log-stream.
1113
1114 - general: Changed the interface to TFormula such that now everything
1115 is parsed by TFormula, which should allow to use phrases even
1116 without paranthesis correctly parsed.
1117
1118 - callisto: replaced the AdHoc number of effective integration slices
1119 in the digital filter by an average of the correct number, averaged
1120 over all possible set of weights. This also gives correct numbers
1121 for the lo-gains which were totally wrong before.
1122
1123 - callisto: drastically reduced memory consumption by not storing
1124 all intermediate calibration results in memory anymore (we might
1125 write them into a file in the future)
1126
1127 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1128 debug plot displayed as a standard plot) use the context menu
1129 somewhere between the two upper plots, click on "DrawNicePlot"
1130 and enjoy the result. (It is the same context menu which contains
1131 the "DrawAll" option)
1132 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1133
1134
1135
1136 *** Version 0.10.2 (2006/10/15)
1137
1138 - general: changed the building of the sequence files such, that
1139 the source-/project name in case of wobble-sources is not the
1140 source/project of the first data run anymore but the new generalized
1141 wobble source/project
1142
1143 - general: Added some functions to MAstro to calculate sun and
1144 moon properties
1145
1146 - general: Added two new macros (starvisday.C and starvisyear.C)
1147 which allow to plot the visibility of several stars in one day
1148 or of one star along one year
1149
1150
1151
1152 *** Version 0.10.1 (2006/10/11)
1153
1154 - general: HTML logging output was distorted... fixed.
1155
1156 - general: Changed the writing of the sequencefiles such that only
1157 as many pedestal files as giving at least 1000 pedestal events which
1158 are nearby the first calibration run are used as pedestal runs
1159
1160 - sponde: In the calculation of the collection area(s) and the
1161 distribution for MOnte Carlo and estimated energy the error
1162 calculation was wrong because root didn't take the errors
1163 properly into account... fixed.
1164
1165
1166
1167 *** Version 0.10 (2006/10/10)
1168
1169 - general: all executables now check consistency of the root version
1170 installed with the root version used for compilation. The return
1171 code in this case is 255.
1172
1173 - general: The algorithm to build seqeunces has been redesigned
1174 completly. It is now more flexible in terms of a resource file
1175 resources/sequences.rc which can be used to partly overwrite
1176 the default algorithm and defined the important part of the
1177 algorithm. It also takes correctly into account several ways
1178 of taking wobble-data. Currently the new algorithm doesn't take
1179 the number of pedestal events anymore into account (so a sequence
1180 could have much less than 1000 pedestal events and data runs are
1181 no-more used instead)
1182
1183 - general: a lot of small changes to make the code compatible with
1184 root 5.12/00 and gcc 4.1
1185
1186 - general: Fixed some warnings thrown if more warnings are switched
1187 on in the compiler
1188
1189 - general: Added a function to MMath which returns the Median of
1190 the distribution abs(y[i]-median) but at 68:32 division instead
1191 of 50:50, which is somehow the median counterpart of the rms.
1192
1193 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1194 even if they are compressed with gzip (recommended compression
1195 is with "-1")
1196
1197 - showplot:
1198 + batch mode creation of image files now works with root 5.12/00
1199 + added support for writing bmp (though it never produces
1200 bmp which can be read by programs like xv or gimp)
1201 + added support for xml
1202 + added new option to start the display with a different size, by
1203 --display-width=nnn or --display-height=nnn
1204 + added options to define the canvas size when the display is started
1205 --canvas-width=nnn or --canvas-height=nnn
1206 the option can also be used for batch-mode conversion
1207 + added an option which automatically fits the display size to the
1208 desktop-size: --auto-size
1209
1210 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1211
1212 - merpp: allow the reports to have 1000ms due to a bug in the camera
1213 program.
1214
1215 - callisto: New swapped pixels have been found and corrected. For
1216 details see MRawRunHeader::FixAssignment()
1217
1218 - callisto: Callisto now raises an error if one of the input files could
1219 not be opened.
1220
1221 - callisto: In some rare cases it could happen that in the signal
1222 extraction of the digital filter the extractor returned nonsense
1223 results due a wrong initializion of a variable (this happens in
1224 cases in which the extracted signal is exactly zero or the
1225 digital filter couldn't slide because of a too small extraction
1226 window, which could happen in the lo-gain extraction)
1227
1228 - callisto: The lo-gains have been marked as valid in some cases
1229 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1230 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1231 smaller than the number of slices (fLoGainWindowSize) needed
1232 by the lo-gain extractor
1233
1234 - callisto: Updated absolute calibration constants (muon calibration)
1235
1236 - callisto: fixed a bug which caused the hi-gain saturation not
1237 to be handled properly in the spline (the position of the
1238 saturation was calculated incorrectly)
1239
1240 - callisto: fixed a bug which gave weird results if hi- _and_
1241 lo-gain could not be extracted properly. In some cases hi-
1242 and lo-gain have not been extracted at all and the random result
1243 got calibrated. In other cases the hi-gain was saturating and the
1244 lo-gain has not been extracted. For this a completly arbitraty
1245 scale factor was applied to the result from extracting the
1246 charge of the saturating hi-gain.
1247
1248 - callisto: improves handling of extracted signal if lo- and/or
1249 hi-gain could not be extracted properly. If no appropriate
1250 calibration of either the signal or the arrival time is possible
1251 the pixel is now markes as unsuitable instead of estimated.
1252
1253 - callisto: Fixed a problem in the spline extraction which gave
1254 weird results if the signal was extracted from the first (and
1255 highest) slice (as a workaround extraction from the first
1256 slice has been forbidden)
1257
1258 - callisto: Fixed a bug regarding the use of the QE which doesn't
1259 effect the result because the default is used anyhow.
1260 (The bug was there since 14/07/2005)
1261
1262 - callisto: Changed the default for fgLoGainStartShift to -2.4
1263
1264 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1265 factors to be always 10 for all pixels as soon as the first
1266 calibration update has happend.
1267
1268 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1269 was off by more than one slice (which gives wrong values for
1270 pixels which have saturated the hi-gain) This was a problem
1271 mainly for timing studies, not so much for the automatic standard
1272 analysis. Also the values for the Spline have been changed slightly:
1273 + Digital Filter from 1.70 to 0.95
1274 + Spline from 1.39 to 1.30
1275 The numbers were sorted out by an extensive test in the
1276 test-database.
1277
1278 - callisto: Removed the tab showing the average calibrated arrival
1279 time. It never gave useful information.
1280
1281 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1282 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1283 and both were extracted because the hi-gain was above the
1284 LoGainSwitch.
1285
1286 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1287 lo-gain pulse position (after application of LoGainOffset, which
1288 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1289 have saturated and both were extracted because the hi-gain was above
1290 the LoGainSwitch.
1291
1292 - callisto: After extensive tests a new threshold level for determination
1293 of the pulse position has been found at 50phe. This is due to the
1294 fact that for lower pulses the arrival time changes its average
1295 behaviour dramatically. It tends to the average of the extraction
1296 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1297
1298 - callisto: Added two more plots to the calibration part. The average
1299 extracted signal and the average extracted arrival time as
1300 extracted by the signal extractor (This can help debugging problems
1301 because it doesn't involve a fit)
1302
1303 - star: changed the fit for the effective on time such that initial
1304 values are calculated automatically now instead of using build
1305 in values. This makes the fit more indepedant of the underlaying
1306 rates. With a test of ~350 sequences in the test database it could
1307 be shown that the new fit gives the same result +/-1sek.
1308 The highest deviation was +5s the lowest -10s. You can now control
1309 the bahaviour with two resource values:
1310 MHEffectiveOnTime.FistBin: 3
1311 MHEffectiveOnTime.NumEvents: 12000
1312 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1313 from the resulting gamma candidates
1314
1315 - star: The Center histogram in MHHillas is now by default displayed
1316 with the colz draw-option
1317
1318 - ganymed: now produces valid error codes if failed
1319
1320 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1321 with the option "hadronness" instead of "area" or "both" if
1322 you want to use both cuts. The hadronness cut includes a fixed
1323 cut in hadronness (index 8) and a fixed cut in size (index 9).
1324
1325 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1326 the M3Long of the anti source to be not properly evaluated
1327 (actually is was evaluated as a unique random number) in case
1328 of optimization with anti-theta cut switched on. This might have
1329 lead to improper, but not necessarily wrong, optimization results.
1330
1331 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1332 how to use random forest
1333
1334 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1335 ganymed_onoff.rc. Seems to be unintentional that they were different.
1336
1337 - sponde: Since the introduction of the possibility to define a
1338 normalization energy instead of using the integral the default
1339 was not using the integral anymore but a normalization energy of
1340 1GeV. It is now the integral again.
1341
1342 - sponde: Fixed a problem in the weighting which did not allow
1343 a MC slope of -1.
1344
1345
1346
1347 *** Version 0.9.6 (2006/05/24)
1348
1349 - general: changed the binning of the azimuthal profile of the camera
1350 such that it is aligned with the 60deg boundaries.
1351
1352 - merpp: better handling of problems with the TH, TD part of the
1353 CC-REPORT for files older than 200507190 and 200412210
1354 respectively
1355
1356 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1357
1358 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1359
1360 - callisto: if an arrival time is extracted outside the fadc range is
1361 was set to the boundary before. Now a random number is assigned
1362 instead to avoid unfortunate coincidences of arrival times just
1363 by this arbitrary value.
1364
1365 - callisto: added a new option to callisto.rc which allows
1366 to set the maximum arrival time difference allowed for the
1367 badpixel algorithm to determin whether a pixels belongs to a shower:
1368 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1369
1370 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1371 to 0.9 as suggested by Stefan due to a recent study on the fraction
1372 of pixels surviving the image cleaning
1373
1374 - callisto: switched off error in case of "pulse is too much to the left"
1375
1376 - callisto: The extraction window is not adapted anymore. This means that
1377 the pulse is extracted from the full range. The draw-back is that the
1378 background (pedestal) will become slightly higher. Switching on/off
1379 the PulsePosCheck in the callisto.rc only effects filling the
1380 histograms.
1381 WARNING: If the pulse is too much to the left data is calibrated!
1382 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1383 in the database to make sure that your data is valid!
1384
1385 - star: Show also the number of stars correlated correctly by the
1386 starguider
1387
1388 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1389 than one off-source region in wobble-mode. To use it add the following to
1390 your ganymed_wobble.rc:
1391 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1392 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1393 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1394 + Cut1.ThetaCut: None
1395 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1396
1397 - ganymed: in the case the latest report is older than a default (currently
1398 one minute) and the current report will be skip the starguider
1399 correction and calibration will be reset. The maximum age can be
1400 setup from ganymed.rc by (minutes):
1401 MPointingDevCalc.MaxAge: 1.5
1402
1403 - ganymed: A first implementation showing all size-bins for the theta-sq
1404 resp. alpha-plots in a single tab automatically
1405
1406
1407
1408 *** Version 0.9.5.1 (2006/05/05)
1409
1410 - general: Added a new option "zdiff" to the Makefile which runs
1411 "cvs diff" as "make diff" would do, but with compression
1412
1413 - general: accelerated MTFillMatrix (used for eample in all training
1414 and optimization macros) by skipping some obsolete calles in the
1415 eventloop the first and second loop could be accelerated by ~20%
1416
1417 - general: Added a missing feature in the MFilterList class which
1418 prevented MFEnergySlope from working correctly in trainenergy.C
1419
1420 - general: Accelerated the random forest training and usage a bit
1421
1422 - merpp: Adapted to new raw data file format version 6
1423
1424 - merpp: fixed a problem with reading the starguider reports
1425 after 6.3.2006
1426
1427 - callisto: At some times six pixels had to be exchanged manually in the
1428 data. If the pixels to be swaped are both not found, an error was raised
1429 and calibration was stopped. Now it is assumed they are intentially not
1430 mapped and the Error has been changed to a Warning.
1431
1432 - star: Added new image cleaning based on the arrival time of the shower.
1433 The new cleaning can be accessed using the parameter "Time" instead of
1434 the the old one (like "Absolute) in the star.rc-file.
1435 Recommended parameters:
1436 + MImgCleanStd.CleanLevel1: 8.2
1437 + MImgCleanStd.CleanLevel2: 5
1438 + MImgCleanStd.CleanRings: 2
1439 + MImgCleanStd.KeepSinglePixels: No
1440
1441 - star: Simplified the calculation of the effective on time. By letting
1442 the fit start in the third bin the result should become more stable.
1443 The fit quality is now ignored for the theta-plot which is not used
1444 in the analysis later. Still better pre-cut which, for example,
1445 remove events triggered by car-light (rate changing on a short
1446 time-scale) are missing.
1447
1448 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1449 for optimization (kWeakSource) which is suggested by the Berlin
1450 people for weak sources.
1451
1452 - macros: plotdb.C:
1453 + if no dataset and no time-interval is given only sequences with
1454 an effective on-time above five minutes are plotted anymore
1455 + added a new tab "RelTime" displaying the relative on-time
1456 (effective on-time divided by the observation time)
1457
1458 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1459 the optimization became a lot faster
1460
1461 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1462 To display them just delete the pads displayed on top.
1463
1464 - ganymed: fixed a bug which could cause strange behaviour in wobble
1465 mode if no starguider information was available due to an incorrect
1466 initialization of the starguider calibration
1467
1468 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1469 be changed from within the plot. It can also be setup from the
1470 resource file using:
1471 + MHDisp.fScaleMin: 0.325
1472 + MHDisp.fScaleMax: 0.475
1473
1474 - ganymed, showplot: Fixed a problem with the fit to the off-data
1475 (HistOff) which could cause a time lag or an inifinite loop.
1476 The bug did not effect the results at all.
1477
1478 - sponde: Added a new tab showing the effective collection area after
1479 trigger (including the software trigger)
1480
1481 - sponde: MMcSpectrumWeight has a new option which allows to define
1482 the scaling factor not by the integral of the events but at
1483 a defined energy:
1484 e.g. MMcSpectrumWeight.NormEnergy: 200
1485
1486 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1487 eventloops the loop could be accelerated by ~20%
1488
1489
1490
1491 *** Version 0.9.5 (2006/03/13)
1492
1493 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1494 and added the standard Disp-parametrization
1495
1496 - macros: added a new macro datacenter/macros/plotstat.C allowing
1497 to plot statistics about the data processing
1498
1499 - macros: added a new macro to plot the muon correction coefficients
1500 versus period (macros/plot/mucal.C)
1501
1502 - showplot: path inflation for ganymed files was broken
1503
1504 - callisto: Fixed an important bug. When the number of saturating pixels
1505 were calculated the bad pixel information already available from the
1506 calibration was ignored. This yields wrong values in case pixels
1507 are broken and saturate all the time or randomly.
1508
1509 - callisto: Updated Muon calibration constants. Spline data now also uses
1510 different values for different periods
1511
1512 - star: The time-evolution shown in the effective on-time plot now displays
1513 the axis range (if there are no holes it should be similar to the
1514 effective on-time)
1515
1516 - star: Added two new image parameters:
1517 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1518 the three pixels next to the center of gravity and the size
1519 + MNewImagePar.fConcCore: The ratio of the signals of all
1520 pixels inside or touching the ellipse and the size
1521
1522 - ganymed: now stops in requested source isn't found in catalog file
1523
1524 - ganymed: Many improvements to the phi-plot in wobble mode:
1525 + with a template the ideal background is displayed
1526 + a possible camera inhomogeneity is taken into account
1527 + the anti theta cut is better supported
1528 + the phi cut is automatically calculated from the theta cut
1529 See the examples in ganymed_wobble.rc for more details.
1530
1531 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1532 times the bin-width instead of the absolute energy
1533
1534 - ganymed: New cuts for on/off and wobble mode
1535
1536 - ganymed: The smearing of the False Source plot has been increased
1537 to 0.06
1538
1539 - ganymed: The starguider calibration can now be changed from the
1540 resource file.
1541 See the examples in ganymed*.rc for more details.
1542
1543 - ganymed: added a new option for on-/off-observations
1544 MJCut.RandomSourcePosition
1545 If switched on the distribution of observation time of the source
1546 position in the camera is calculated from the on-data and randomly
1547 applied with this distrbution to the off-data.
1548
1549 - ganymed: by skipping some obsolete calles in the eventloop the
1550 first and second loop could be accelerated by ~20%
1551
1552 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1553 position in the off-data randomly according to its distribution in the
1554 on-data.
1555
1556
1557
1558 *** Version 0.9.4.3 (2006/02/13)
1559
1560 - general: Fixed a bug in most of the programs which prevented the
1561 compile date in the startup message to be displayed
1562
1563 - general: Simplified program calls. The following abbreviations
1564 are now possible:
1565 showlog callisto 55599
1566 showplot signal 55599
1567 star 55599
1568 callisto 55999
1569 ganymed 2
1570 In this cases the corrsponding root-, log-, sequence- or dataset-
1571 filename is automatically compiled using the default datacenter
1572 paths ("/magic/*")
1573
1574 - general: Fixed a long outstanding bug which made axis tick marks
1575 disappear if MDataFormula was used (eg. abs(x))
1576
1577 - general: Updated MMath with new functions to calculate the results of
1578 a exponential, logarithmic and powerlaw fits analytically.
1579
1580 - general: Updated some macros with comments:
1581 + macros/optim/optimdisp.C
1582 + macros/optim/optimenergy.C
1583 + macros/optim/optimwobble.C:
1584
1585 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1586 files) now allows adding a pre-cut like in the optimization. E.g. this
1587 is useful to perform g/h-separation cuts before training the random
1588 forest.
1589
1590 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1591 correctly assigned in the raw data assignement table. A fix to correct
1592 the assignment tabel have been implemented.
1593
1594 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1595 by 90, 180 and 270 deg.
1596
1597 - general: the macro plotdb.C now allows to highlight sequences belonging
1598 to a datset. For more details see the descritions in the macro.
1599
1600 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1601 of the display, it gave wrong results espacially for big sizes.
1602 Now the embedded canvas should always have a ratio width/height=3/2.
1603 The "Size" options have been updated with values fitting the 3/2
1604 size ratio.
1605
1606 - RanForest:
1607 + Updated the random forest classes to support also the
1608 regression method implemented by Thomas H.
1609 + added new tutorial macro how to train the random forest
1610 for energy estimation (macros/optim/rfenergyest.C)
1611 + new classes to train the random forest (still in development)
1612 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1613 + new tutorial macros for random forest training in macros/train
1614 trainenergy.C, traindisp.C, trainseparation.C
1615
1616 - mars: now allows to setup a cut in the resource file mars.rc to choose
1617 the events to be displayed, eg:
1618 Cut.Condition: {0} && {1}
1619 Cut.0: MHillas.fSize>100
1620 Cut.1: MHillas.fSize<900
1621
1622 - merpp: Made aware of the new .rep format 200510250. This includes
1623 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1624 the discriminator thresholds (MCameraTD) and the disciminator
1625 delays (MCameraTD). All of them come with the CC report and are therefor
1626 written to the CC tree.
1627
1628 - callisto: fixed a bug in the calculation of the arrival times in
1629 the Digital Filter. They were all shifted by the same amount
1630 fHiGainFirst. This caused an offset in the order of the position of
1631 the left border of the extraction window in the times calculated
1632 from high-gain and from low-gain. The bug effected only the absolute
1633 arrival times. The bug was there since 30.1.2005.
1634
1635 - callisto: Changed the ExtractionWindow for the pulse position check
1636 such that the camera inhomogeneity becomes as less as possible and
1637 comparable to the pulso position check switched off. More details
1638 on the study will be given at our result web-page.
1639
1640 - ganymed: ganymed.rc, ganymed_onoff.rc:
1641 changed to new cuts trained with 1ES1218 and Crab-data
1642 for maximum sigma*log10(excess)
1643
1644 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1645 a new option was implemented to estimate Disp (CalcDisp)
1646
1647 - ganymed: Implemented two new options which allow
1648 to overwrite the default path to search for the sequence files
1649 --ins=/magic/sequences
1650 and where to search for the image data
1651 --ind=/magic/data/star
1652
1653 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1654 dx/dy from the resource file by
1655 MSrcPosCorrect.Dx
1656 MSrcPosCorrect.Dy
1657
1658 - ganymed: fixed reading the source catalog. Only as many chars
1659 as the requested source name had were compared (If a source
1660 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1661 were requested it could happen that the coordinates of
1662 "1ES1218" were read) The source coordinates are now printed
1663 in addition to its name to the logging output.
1664
1665 - ganymed: changed the background fit in the case of a ThetaSq function
1666 from a polynomial to a exponential, this should give a big improvement
1667 for on-only analysis'
1668
1669 - ganymed/sponde: Calculation of the error of single size-/energy-
1670 bins now uses Li/Ma (5) instead of LiMa (17)
1671
1672 - sponde: Added a plot E^2*dN/dE
1673
1674 - sponde: The energy estimator plot should now show values like
1675 they are commonly used.
1676
1677 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1678 (a powerlaw with cutoff didn't work before)
1679
1680
1681
1682 *** Version 0.9.4.2 (2005/10/01)
1683
1684 - general: added new tutorial macro macros/tutorials/threshold.C:
1685 how to calculate the threshold
1686
1687 - general: added a new game. Start it from the interpreter with
1688 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1689 and MagicReversi)
1690
1691 - general: neighbor pixels in MGeoms are now sorted clockwise
1692
1693 - merpp: made aware of new format 20050829-0
1694
1695 - callisto: New scale factors from muon analysis, stored in new
1696 resource file resources/calibration.rc
1697
1698 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1699 the eventloop if something went wrong. This is necessary for the
1700 automatic processing
1701
1702 - callisto: Implemented a new treatment for the time information
1703 developed by S.Ruegamer, this should give much better response than
1704 the old very primitive algorithm. This is especially important
1705 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1706 treatment was buggy! As neighbor pixels to interpolate the
1707 arrival times always the pixels 0 to 5 were taken)
1708
1709 - callisto: In addition to the new treatment of arrival times the
1710 decision of the treatment whether a pixel contains shower
1711 information or not is used to improve the signal interpolation
1712 further. Previously interpolated pixels showed a non-zero signal
1713 do the peak searching signal extractors. Having a signal pixel
1714 beside raised the signal above the cleaning level. Thus the
1715 pixel survived cleaning to often but with a too low mean signal.
1716 By replacing empty pixels with a gaus (mean and rms from the
1717 corresponding Area entries in MPedPhotCam) this effect can
1718 be supressed.
1719
1720 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1721 got lost when the events were stored by the calibration... fixed.
1722 (This was no problem for normal image cleaning because the pixel
1723 content was artificially set to 0 not surviving standard cleaning
1724 algorithm)
1725
1726 - callisto: Fixed a bug which caused the random and peak-search pedestal
1727 extracted with an extractor to be exchanged for the first (roughly)
1728 500 events (*Extractor and *ExtractorRndm).
1729 (They were simply exchanged in callisto.cc) This bug might have been
1730 introduced in Mars 0.9.4 when the order of calculation of the two
1731 types of pedestal in callisto got exchanged. The bug only effects
1732 the first seconds of data of each sequence.
1733
1734 - star: Taking the arrival time of Muons into account the calculation
1735 of the parameters could be made independant of the noise
1736 (pedestal rms). The dependance was due to the bias of the peak search
1737 extractor. Now only a ZA dependamcy is left which is not yet fully
1738 understood.
1739
1740 - ganymed: The sequences were still not sorted correctly in any case,
1741 because they were sorted by the full qualified path name. Now they
1742 are sorted by their sequence number.
1743
1744 - ganymed: new values for the spark-event-cut
1745
1746 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1747
1748
1749
1750 *** Version 0.9.4.1 (2005/08/18)
1751
1752 - callisto: fixed some problems with the calibration in case of
1753 inteleaved events. Therefor the final and some intermediate
1754 fits are skipped which would take place on partly filled #
1755 histograms and gave wrong results or failed completely.
1756
1757 - callisto: If the intermediate finalization of the histograms
1758 calculating the mean charge of the calibration signal fails
1759 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1760
1761 - ganymed: Fixed some bugs which caused problems in On-only mode.
1762 Still the false source plot doesn't give reasonable results.
1763
1764
1765
1766 *** Version 0.9.4 (2005/08/05)
1767
1768 - general: Fixed the ZA binning. It did not correctly fit the
1769 MC binning
1770
1771 - general: Added a class to correct for the missfocussing in
1772 April (MSrcPosCorrect)
1773
1774 - general: Random Forest energy estimator should now work properly
1775
1776 - general: MHCamera now displays the profiles in deg instead of mm
1777
1778 - general: MH::SetPalette offers a lot of new palettes
1779
1780 - general: MHillas - the case of CorrXY==0 is now handled properly
1781
1782 - general: implemented the possibility to change the line and
1783 marker style of a sky-grid drawn by MAstroCatalog
1784
1785 - general: Runs in sequences and datasets are now automatically
1786 ordered (it is assumed that the order of their filenames correctly
1787 represents the order of observations) to ensure correct reading
1788 of the subsystem data
1789
1790 - general: Runs cannot be added to a sequence twice anymore. Also
1791 Sequences cannot be added twice anymore to a dataset.
1792
1793 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1794 It gave wrong results by 1./2pi
1795
1796 - showplot: got a new option to start a root interpreter, too
1797
1798 - mars: now displays a rough estimate of Disp and the third moment
1799
1800 - mars: now displays the event time MTime if available
1801
1802 - mars: show muon parameters graphically
1803
1804 - mars: now the file to open can be given as commandline
1805 argument
1806
1807 - merpp: Added support for new arehucas version >= 200507190
1808 implementing values for three temperature sensors in the
1809 counting house (MCameraAUX) and the name of the HV settings file
1810 (MCameraHV).
1811
1812 - merrp: Also fixed some problems with wrong versions numbers stated
1813 by arehucas and implemented some fixed for old versions (<200407070)
1814
1815 - callisto: MCalibrationHiLoCam can now be printed from its context
1816 menu, eg in the TBrowser
1817
1818 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1819 - 1.39 (MExtractTimeAndChargeSpline)
1820 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1821 This is important mainly for timing studies.
1822
1823 - callisto: Changed limits in MHCalibrationChargeCalc from
1824 - -100.125 to -98 (fgChargeHiGainFirst)
1825 - 1899.875 to 1902. (fgChargeHiGainLast)
1826 - -100.25 to -99 (fgChargeLoGainFirst)
1827 - 899.75 to 901. (fgChargeLoGainLast)
1828 Introduced new limits:
1829 - fgNumLoGainBlackoutLimit: 0.05
1830 - fgLoGainBlackoutLimit: 3.5
1831 - fgLoGainPickupLimit: 3.5
1832
1833 - callisto: The handling of automatic weights for the digital filter
1834 has been improved. There are now new calibration weights special
1835 for Monte Carlo calibrations.
1836
1837 - callisto: Updated Muon scale with latest results (1% difference
1838 for most data, 5% for Mar/Apr'05)
1839
1840 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1841 was saturated and the blackout-events in the low-gain exceed the
1842 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1843 This excludes those pixels which have a saturating high-gain
1844 channel, but the low-gain switch does not switch often enough
1845 to make the distribution reliable.
1846
1847 - callisto: fix a bug counting the number of saturated events. Up to now,
1848 the number of saturated slices was counted (which is one for a not too
1849 high number), but for some (pathological) pixels, many more slices
1850 saturated and produced wrong limits.
1851
1852 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1853 + MCalibrationRelTimeCam.CheckFitResults: Yes
1854 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1855 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1856 + MCalibrationRelTimeCam.CheckOscillations: Yes
1857
1858 - callisto: introduce max. number of events for intercalibration,
1859 the rest gets skipped. Default: 4096
1860 The calibration causes too many un-reliable pixels if more
1861 than about 5000 events are treated (@500 Hz) because of the
1862 mode hopping of the VCSels. However, in the past, some
1863 calibration runs have been taken (erroneously) with more
1864 than 5000 events, especially the intensity scans where
1865 a good precision is needed.
1866
1867 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1868 photo-electrons for the spline extractor by 1-2% (correctly).
1869
1870 - callisto: The intercalibration is now done using a full f-factor
1871 method instead of a simple update. This makes things slower but
1872 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1873 changes.
1874
1875 - callisto: MPedestalY3 now uses the same extraction range as the data
1876 as calculated by MPedestalY2
1877
1878 - callisto: A check of the fraction of allowed unsuitable (10%) and
1879 unreliable (30%) pixels has been addded when the conversion is
1880 calculated from interleaved events
1881
1882 - star: fixed a bug which caused MEffectiveOnTime containers not to
1883 be written. In the worst case they were skipped almost all, in the
1884 best case they were all ok. It depends on how often the new value
1885 was assigned just with an event which was skipped later by another
1886 task
1887
1888 - star: new histograms MHPointing and MHRate
1889
1890 - star: New tab (Currents) displaying the time evolution of the mean
1891 DC currents
1892
1893 - star: New tab (MeanRms) displaying the time volution of the mean
1894 Pedestal Rms
1895
1896 - star: Output now contains MReportStarguider
1897
1898 - star: Improved muon analysis. Due to the absense of a constant
1899 for the gaus fit for arc width and the fact that the arcwidth
1900 plot was a histogram instead of a profile the resulting psf
1901 became pedestal rms dependant
1902
1903 - ganymed: added new plot (MHPhi) for wobble mode as described in
1904 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1905
1906 - ganymed: corrects now (correctly?) for the misspointing in
1907 May/April 05
1908
1909 - ganymed: Two new default templates for ganymed.rc are avilable:
1910 ganymed_onoff.rc and ganymed_wobble.rc
1911
1912 - ganymed: The first version of MFMagicCuts has been released
1913
1914 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1915
1916 - ganymed, sponde: There are two new options to determin the number
1917 of bins for the signal region (NumBinsSignal) and the number of
1918 total bins (NumBinsTotal) in the MHThetaSq histogram
1919
1920 - ganymed: optimized palettes for MHDisp
1921
1922 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1923 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1924 sqrt(2) to large
1925
1926 - ganymed: The false source plot (MHDisp) is now based on Disp
1927 and a background model determined in the first loop is
1928 subtracted
1929
1930 - ganymed: MFMagicCuts are now available in the cvs. The correct
1931 solution for the disp ambiguity problem is now calculated using
1932 the third moment. The third moment cut therefor is skipped.
1933
1934 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1935 already determined by the third moment along the major axis and
1936 so its actual sign is aligned along the major axis of the shower.
1937
1938 - ganymed: If starguider data is available it is taken into account
1939 when calculating the source position. This is especially important
1940 for wobble data at high zenith angles and culmination data.
1941
1942 - ganymed: If available the starguider data is taken into account as
1943 good as it is possible without a starguider calibration. To switch
1944 it off add
1945 MPointingDevCalc.MaxAbsDev: -1
1946 to your ganymed.rc
1947
1948 - sponde: the zenith angle distribution is now weighted instead of
1949 choosen by default. This gurantees higher statistics in the highest
1950 and lowest energy bins. To switch this behaviour off use...
1951
1952 - sponde: now automatically displays the energy threshold
1953
1954
1955
1956 *** Version 0.9.3 (2005/06/03)
1957
1958 - general: MMcEvt now derived from MMcEvtBasic which should
1959 have no influence on compatibility with older camera files
1960
1961 - general: Implemented a new option to MReadReports which allows
1962 to force reading of the first event of some trees (eg. Drive-tree)
1963 before any other tree.
1964
1965 - general: Made a fix to MPointingPosCalc which assumes that the
1966 run-type is real-data if Process is called before ReInit, such
1967 that also the very first Drive-events in a run are treated
1968 correctly.
1969
1970 - shoplot now displays the filename in the title bar of the window
1971
1972 - merpp: new options: --auto-time-start --auto-time-stop which
1973 allow to cut updating with slow-control at the start- or
1974 (previousle --auto-time only allowed: and) stop-time of
1975 the run stored in the runheader.
1976
1977 - callisto: changed default of fgFallTimeHiGain in
1978 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1979 already set as default in callisto_Dec04Jan05.rc
1980
1981 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1982 now changes the filename for new weights automatically for
1983 cosmics, MC and for different calibration colors.
1984
1985 - callisto: a problem with the order of some code cause the
1986 name of the weights file in MPedestalY2 to be ignored.
1987 Wrongly the calibration_UV weights were used instead
1988 of the cosmics weights set in callisto.rc.
1989
1990 - callisto: should allow ct1 pulser data when the color is
1991 explicitly set also for pretty new runs
1992
1993 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1994 to introduce an additional scale factor (should be around 1)
1995 to adapt for slight deviations in different extractors from
1996 the MC calibration. For MC calibrations the scale factor
1997 is fixed to 1
1998
1999 - callisto: MFCosmics should handle very high signals a bit
2000 more accurate now
2001
2002 - callisto: when calculating the mean pedestal rms for different
2003 pixel sizes or sectors also kUnsuitableEvt is now taken into
2004 account - not only kUnsuitableRun
2005
2006 - callisto: '-raw' option is now the default
2007
2008 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2009 This has the advantage that mean values in the calibration (eg
2010 arrival times) are calculated more accuratly.
2011
2012 - callisto: In the resource file callisto_Dec04Jan05.rc
2013 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2014
2015 - callisto: new Hi-/Lo-Gain intercalibration constants
2016 hilocalib_sp1.root and hilocalib_sp1_mc.root
2017
2018 - callisto: changed default for MJPedestalY2.MaxEvents
2019 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2020
2021 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2022 has changed from 9.0 to 6.0. This is necessary to exclude two very
2023 ringing pixels in September which - when kept - destroy the image
2024 cleaning around them (Markus G.)
2025
2026 - callisto: (!) The Muon analysis of all data taken so far has
2027 suggested that different extractors give slightly different
2028 absolute results after calibration, due to there different
2029 handling of the calibration- and cosmics pulse shape. Although
2030 the over all calibration seems to be a bit to pesimistic (or
2031 the MC seems to be a little bit - 3-5% - too much attenuated).
2032 There for correction factors have been introduced which correct
2033 the calibration constants by
2034 0.956937799 for Digital Filter (callisto.rc)
2035 and
2036 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2037 calibration. The main advantage is, that both data types can
2038 be easily analysed together and compared to the same MC sample.
2039 The factors are choosen such, that the reference is now a
2040 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2041
2042 - star: fixed a bug which caused the first bin of the histograms
2043 vs time to disapear in PostProcess. This gave wrong results
2044 on the screen. The output and all following programs not
2045 directly accessing the histograms haven't been affected
2046
2047 - star, ganymed: Made sure that always the first Drive-tree event
2048 is read and Processed before the first data event was read.
2049
2050 - ganymed: implemented the possibility to replace the standard
2051 false source plot with a different one. For example: If
2052 you want to use a Disp based FS plot use the resource:
2053 NameHistFS: MHDisp
2054 For details about the requirements of these plots look
2055 at the corresponding classes
2056
2057 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2058 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2059 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2060 case MAlphaFitter is setup correctly. For On-Only optimization
2061 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2062 RunOn() instead of Run(). For energy estimation MJOptimize
2063 has been replaced by MJOptimizeEnergy
2064
2065 - sponde: The input MC spectrum can now be weighted to fake a
2066 different spectrum. This is done via MMcSpectrumWeight. For
2067 more details see the class description and sponde.rc
2068
2069 - sponde: The paremeter comparsion plots are not scaled by
2070 their entries anymore. Instead the MC plot is scaled by using
2071 the result spectrum of the analysis. If the input MC spectrum
2072 and the result spectrum has different slopes the absolut
2073 normalization is normally wrong.
2074
2075
2076
2077 *** Version 0.9.2 (2005/05/20)
2078
2079 - general: Changed the default paths for calibrated data and image
2080 files. (The implemented access to these files doesn't yet exist)
2081
2082 - general: support for MRunIter has been removed from the job classes
2083 (use the setter functions of MSeqeunce instead)
2084
2085 - general: ProcessFile has been renamed to Process in all job classes,
2086 because ProcessFile is missleading
2087
2088 - general: The storage of the palette in MHCamera is now possible
2089
2090 - general: new bits describing unsuitable and unreliable pixels have
2091 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2092 kDeadPedestalRms, kFluctuatingArrivalTimes
2093
2094 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2095 versions newer than V200404070
2096
2097 - general: support for cc file versions newer than V200504130. Added
2098 support for active loads (MCameraActiveLoad) and central pixel
2099 (MCameraCentralPixel)
2100
2101 - general: added new histograms for image parameters versus size
2102 (MHVsSize)
2103
2104 - general: The eventloop now automatically calls PrintStatistics
2105
2106 - Status Display: Improved support for printing:
2107 + A default can now be set in .rootrc (for more details see
2108 MStatusDisplay::PrintPS)
2109 + A print dialog is opened so that printer and command line
2110 can be canged
2111
2112 - showlog: improved such that it handles different verbosity levels
2113 more accurate now. This mean you can suppress output when
2114 using showlog.
2115
2116 - showplot: improved
2117 + The new graphics formats have been implemented
2118 (pdf, svg, png, jpg and xpm)
2119 + Implemented an interface for printing. Because you can change
2120 the printing command from the command line you can use all
2121 the nice postscript tool. To print a booklet for example call:
2122 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2123 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2124 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2125
2126 - callisto: fixed a bug in the recognition of the calibration bit
2127 pattern. Concerns only intensity calibration. (The strength of the
2128 intensity has been updated in some cases)
2129
2130 - callisto: add a filter against PIN Diode events when running over
2131 calibration runs since some of the recent calibration runs have
2132 been taken with Pin Diode.
2133
2134 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2135 39943, 44833 in the calibration (MCalibColorSet)
2136
2137 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2138 been set to 1e-18 in callisto_Dec04_Jan05.rc
2139
2140 - callisto: in callisto_Dec04Jan05.rc: set value for
2141 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2142 statistics for the calculation of the mean pulse time
2143 of the cosmisc
2144
2145 - callisto: the charge limit in the calibration has been raised
2146 from 2.5 to 4.5
2147
2148 - callisto: new setup read from callisto.rc
2149 + MCalibCalcFromPast.fNumEventsDump
2150 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2151 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2152
2153 - callisto: MExtractTimeAndChargeSpline extractor:
2154 + The integration ranges were shifted by 0.2 FADC slices to the right.
2155 + unreliable handling of floating point values caused different
2156 results on different platform or with different compiler options:
2157 The new algorithm is numerically exact and more accurate because
2158 it doesn't calculate the integration position by multiple times
2159 adding the step-size (which results in numerical uncertanties
2160 exspecially if multiplied with large numbers)
2161 + A lot of fixes have been introduced which effects integrating the
2162 spline at the edges of the valid range. In this case any memory
2163 was randomly accessed. This behaviour can be tested replacing
2164 all MArrayF by TArrayF which perform a range check (but of course
2165 they are a lot slower)
2166 ! No result obtained with the Spline before can be trusted! Due to
2167 random memory access it might by completely random!
2168
2169 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2170 + extraction range in the high gain to 4.
2171 + weights file to cosmics_weights46.dat
2172
2173 - callisto:
2174 + introduce the check for fluctuating arrival times.
2175 + set charge limit to from 2.5 to 4.5
2176 + introduce asymmetric exclusion due to "deviating number of phes":
2177 Default: -9.0 +4.5
2178 + make deviating number of phes unsuitable (see David's findings).
2179
2180 - callisto: fixed the display of unsuitable pixels. The old change
2181 to a real profile in MHCamera broke it.
2182
2183 - callisto: The cosmics filter is used in MJCalibration now
2184 independant of the pulser color (formaly it was used only for
2185 CT1-pulser data). The threshold of number of max empty pixels
2186 has been raised from 2% to 5% in MJCalibration. The maximum
2187 fraction of rejected event is 50% otherwise the calibration has
2188 failed. The filter now ignores unsuitable pixels.
2189 Setup the filter from callisto.rc using "ContCosmics"
2190 (see MFCosmics::ReadEnv)
2191
2192 - callisto: changed default for fgOffsetFromLogain back
2193 from -2.8 to -1.8 in digital filter.
2194
2195 - callisto: for the common extractors
2196 + MExtractFixedWindow
2197 * MExtractTimeAndChargeSlidingWindow
2198 * MExtractTimeAndChargeSpline
2199 * MExtractTimeAndChargeDigitalFilter
2200 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2201 and fResolutionPerPheLoGain
2202
2203 - callisto: Updated the hi-/lo-gain intercalibration constants
2204 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2205 hilocalib_df6.root
2206
2207 - callisto: The default lo-gain extraction window for the
2208 MExtractTimeAndChargeSlidingWindow extractor has been increased
2209 from 6 to 8 to take the stretch of the pusle into account
2210
2211 - callisto (!!!): fixed an important bug in the setting of the
2212 incoming pedestal pointer to the signal extractor extracting
2213 pedestals. This bug caused the pedestals not to be subtracted
2214 correctly in the calibration afterwards. The effect was about 10%
2215 too high conversion factors for the digital filter and the spline
2216 and more than 40% for the sliding window.
2217 The bug existed since end of February! (Markus G.)
2218
2219 - star: added muon support to star. A new tab "MHMuonPar" is
2220 displayed. The lower right plot is an estimate of the point spread
2221 function. A reference value is displayed. To get the real PSF
2222 you must compare with MC. The setup for the muon analysis
2223 is done in star.rc. More informations can be found in
2224 MHSingleMuon and MHCalibParCalc
2225
2226 - star: The weather data is now displayed in star
2227
2228 - star: MEventRateCalc handles the calculation of the event rate more
2229 accurate now in case of the start of a new run inside a sequence
2230
2231 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2232 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2233 changed only minimally
2234
2235 - ganymed: (MJCut and MJOptimize) now displayes the number of
2236 excess events versus size. The energy estimation is done in
2237 MJSpectrum (sponde)
2238
2239 - ganymed: got support for using other variables than Alpha, eg. Theta.
2240 Therefor you need a class deriving from MHAlpha which supports
2241 this variable (one is already existing: MHTheta, which is now the
2242 default in ganymed). It is setup through ganymed.rc
2243
2244 - added a full featured spectrum program (sponde) which reads
2245 ganymed output and monte carlos and compiles a spectrum
2246
2247
2248
2249 *** Version 0.9.1 (2005/04/14)
2250
2251 - Fix bug on the arrival time reconstruction when using Digital
2252 Filter (in some marginal cases (10%) times were reconstructed shifted
2253 by 0.2 slices)
2254
2255 - all executables now return 2 where in previous versions -1 has
2256 been returned (gave problems with shell-scripts)
2257
2258 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2259 also done with a intercalibration input file
2260
2261 - a bug in the time fine adjustment of the digital filter has been fixed
2262
2263 - a lot of small fixes to calling TPad::Divide with a margin==0
2264
2265 - MStatusDisplay now shows the memory usage
2266
2267 - added a memory leak statistic after the eventloop
2268
2269 - MHadronness replaced by MParameterD
2270
2271 - MEnergyEst replaced by MParameterD
2272
2273 - wobble mode can now be switched on from the data-set
2274
2275 - switched on bad pixel detection for a pedestal level
2276 which is more than 5 times the variance
2277
2278 - Fixed default paths to be correct for the new data center
2279
2280 - Fixed handling of drive data. The pointing position in now
2281 copied to MPointingPos inside star for real and MC events
2282
2283 - made sure, that the sequences in a dataset are sorted by
2284 their number to ensure the correct synchronization
2285
2286 - added all resource files necessary to handle spline extraction
2287 of signal for the late 2004 and the early 2005 data
2288
2289 - update the reference lines for the december data
2290
2291 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2292 This is important for the Dec. and Jan. data where the calibration
2293 pulse position changes much.
2294
2295 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2296 filter. This corrects only an defective extraction of the MC at
2297 low-gain signals lower than 90 phes.
2298
2299 - fixed some slowdown in calibrating data with interleaved events from
2300 Jan and Dec. As a workaround made the pretty palette the default.
2301 The inverse Deep Blue Sea has a bug which slows down long calibration
2302 runs a lot.
2303
2304 - implemented new values from new starguider report as defined
2305 in TDAS00-07 V7.1 (eg SkyBrighness)
2306
2307 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2308 in starguider report (If you merpp the same reports with this version
2309 you'll get the correct units (arcmin) but a different result
2310 than with old versions (wrong units))
2311
2312 - Now the status display can also write PNG, JPEG and XPM (other file
2313 formats are still unsupported by root)
2314
2315 - added a lot of scripts and macros in directory datacenter used
2316 for automatic processing
2317
2318
2319
2320 *** Version 0.9 (2005/03/23)
2321
2322 - Calibration is now done autmatically into photo-electrons like
2323 decided by the Collaboration Board
2324
2325 - Reference lines in the display can be read from resource file
2326
2327 - Interlaced calibration events can be handled by callisto
2328
2329 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2330 and applied in callisto.
2331
2332 - class MJCalibTest can be called by callisto
2333
2334 - callisto can now run with three data types: rawdata, rootdata, MC
2335
2336 - added two classes mreport/MReportStarguider.cc and
2337 mreport/MReportStarguider.h for implementing starguider-data
2338
2339 - the output of merpp-update now contains starguider information:
2340 MReportStarguider and MTimeStarguider
2341
2342 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2343 values were lower than they should. This was more visible for high
2344 energy (Size) events.
2345
2346 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2347
2348 - added a new loop to callisto to support the correct extraction of
2349 the pedestal and pedestal rms through the signal extractor
2350
2351 - added class to perform fourier tranformation of a hexagonal structure
2352 (MHexagonalFT)
2353
2354 - added class to perform fourier tranformation of a hexagonal structure
2355 in a tasklist (MHexagonalFTCalc) example: hft.C
2356
2357 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2358 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2359 small pixels, example: extendcam.C
2360
2361 - added possibility to write data to memory (TTree) using MWriteRootFile
2362
2363 - added possibility to read a TTree stored only in memory by MReadTree
2364
2365 - new classes to deal with the interleaved calibration events:
2366 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2367
2368 - implemented filters to callisto to skip calibration events
2369
2370 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2371 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2372 the slices by statistics
2373 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2374 signal extractor without randomization
2375 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2376 with the signal extractor with randomization (extraction window is
2377 randomly fixed)
2378 The three kind of pedestal is not yet implemented (for speed reasons) as
2379 long as nobody really needs it:
2380 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2381 extracted with the signal extractor with randomization
2382
2383 - callisto now finds the pulse position in the data automatically
2384
2385 - implemented data reduction in calibrated data by reducing the precision
2386 of the stored floating point values (pedestal, rms and signal) to
2387 roughly 0.5%
2388
2389 - fixed showplot to make file format conversion (eg. converting a
2390 status display stored in a root file into a postscript file) in
2391 batch mode possible:
2392 showplot -b --save-as-ps[=outfile.ps] infile.root
2393
2394 - Allow class names as part of filter rules, eg
2395 (MFSupercuts) && (MHillas.fSize>100)
2396
2397 - fixed a lot of stuff to allow all programs to process MonteCarlo
2398 camera files.
2399
2400 - enhanced possibility to debug reading of resource file
2401
2402 - MDataChain should handle priorities of operator more
2403 accurate now
2404
2405 - completely revised the container in which the signal is stored
2406 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2407 * the new implementation is faster and
2408 * needs less storage space
2409
2410 - FIRST version which can process Monte Carlos through the
2411 whole chain of programs (callisto, star, etc)
2412
2413 - implemented new image parameters for the border length of
2414 the shower image (MNewImagePar2)
2415
2416 - implemented wobble-mode in ganymed
2417
2418 - new class (MJOptimize) taking care of all optimization processes
2419
2420
2421
2422 *** Version 0.8.6 (2004/10/05)
2423
2424 - New combined signal and time extractor
2425 MExtractTimeAndChargeDigitalFilter
2426
2427 - The Report for the trigger section in the CC run summary has been
2428 updated, and now the IPRs (Individual Pixel Rates) are available.
2429
2430 - new macros for database interaction: filldotrun.C, filldotrbk.C
2431
2432 - added new program which can convert colored output which was redirected
2433 into a file back into colored text (for example to display it with
2434 more): showlog
2435
2436 - added new program to display an MStatusArray of plots (stored with
2437 MStatusDisplay) from a file: showplot
2438
2439 - Added support for Sequences (MSequence). Sequences are blocks of run
2440 files containing the same calibration and belonging to the same
2441 source
2442
2443 - Added a new task (MTaskEnv) which can be used in setup files to switch
2444 between different tasks (for example to choose a signal extractor)
2445
2446 - Implemented automatic file splitting in MWriteRootFile
2447
2448 - After image cleaning an island index is assigned to all used pixels.
2449 The index corresponds to the order of the islands in size.
2450
2451 - added a cleaning which takes signal height _and_ arrival time into
2452 account: probability cleaning (for more details see MImgCleanStd)
2453
2454 - added a cleaning which takes takes the absolute number of photons
2455 times the area ratio as cleaning level
2456 (for more details see MImgCleanStd)
2457
2458 - Changed calculation of image parameters such, that it can be done
2459 for all used pixels or the pixels with a defined island index only
2460
2461 - implemented new image parameters displaying the number of islands,
2462 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2463
2464 - event display in executable changed to support also calibrated files
2465 (done with MJCalibrateSignal)
2466
2467 - added program doing the calibration and the signal extraction
2468 and signal calibration: callisto Most part of the setup is done
2469 by a resource file: callisto.rc
2470
2471 - implemented support for pixels with negative IDs (Raw file format
2472 version 4)
2473
2474 - implemented an new option in merpp (--auto-time) to get the time
2475 range for cc and/or caco data from the run header of the raw data
2476
2477 - New star-program (star and MJStar). Taking calibrated data from
2478 callisto/MJCalibrateSignal as input. The setup is done through
2479 a resource file: star.rc
2480
2481 - Added possibility to setup the eventloop in the mars-executable
2482 Camera Display by a resource file: mars.rc
2483
2484 - The the mars-executable Camera Display can now also read
2485 calibrated data files written by callisto/MJCalibrateSignal
2486
2487 - Added a new class which can calculate the source position in
2488 the camera from a pointing model known to be correct and
2489 the pointing model used for observations (MSrcPosFromModel)
2490
2491 - added a new version of the class calculating the effective on-time
2492 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2493 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2494 MHTimeDiffTheta.
2495
2496 - added the possibility to count how often a signal is above (or
2497 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2498 can replace MHTriggerLvl0)
2499
2500 - added ore convinient ways to set the axis-titles of your histograms
2501 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2502 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2503
2504
2505
2506 *** Version 0.8.5 (2004/08/06)
2507
2508 - new Signal Extractors: MExtractFixedWindowSpline
2509 and MExtractAmplitudeSpline
2510
2511 - implementes interleave in merpp to be able to merpp parts of a file
2512
2513 - implemented force-functionality to merpp
2514
2515 - star display to display star catalogs (MAstroCatalog)
2516
2517 - star display to 'mirror' stars to the camera (MAstroCamera)
2518
2519 - implemented a new cleaning option which allows cleaning scaled with
2520 the real ratio of the rms depending on the pixel size, not only the
2521 square root of the pixelsize (MImgCleanStd, MCameraData)
2522
2523 - removed obsolete MBlind* classes
2524
2525 - Signal extractor taking the AB flag into account implemented (this makes
2526 an odd number of slices for signal extraction possible
2527 (MExtractSignalABcorr)
2528
2529 - implemented a class extracting the pedestal from the raw-data (events)
2530 itself using empty lo-gain (MpedCalcFromLoGain)
2531
2532 - Added mean values to MPedPhotCam
2533
2534 - Added Makefile for Darwin (this OS is NOT officially supported!)
2535
2536
2537
2538 *** Version 0.8.4 (2004/04/19)
2539
2540 - new fast arrival time extractor using cubic splines:
2541 MExtractTimeFastSpline
2542
2543 - implementes multi-argument support in MDataChain
2544 ("pow(a, b)")
2545
2546 - implemented double reference support in MDataChain
2547 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2548
2549 - added support in MF for expressiond like
2550 "MHillas.fWidth<2*<MHillas.fLength"
2551
2552 - MDataChain is now able to support variables like [0], [1], ...
2553 which can be used in fit functions as parameters. The interface
2554 is implemented through the new virtual function
2555 MParContainer::SetVariables
2556
2557 - added new class MArrivalTimeCam/MArrivalTimePix:
2558 Storage containers to hold the ArrivalTime of the camera/pixel
2559
2560 - added new classes for the calibration of relative arrival times:
2561 MCalibrationRelTimePix and MCalibrationRelTimeCam
2562
2563 - added new classes to extract the signal of the blind pixel and the
2564 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2565
2566 - added new classes for the bad-pixels treatment (MBadPixels*)
2567 which are more powerfull than the old ones (MBlindPixel*)
2568 and will replace them.
2569
2570 - added filter against cosmics: MFCosmics
2571
2572 - added new class MArrivalTimeCalc2:
2573 Calculates the arrival time as the signal weighted mean of the time
2574 slices in the maximum window
2575
2576 - added a new macro call pointspreadfucntion.C that fits with a 2D
2577 gaussian the DC spot for an star. It gives you the RMS of
2578 the PSF and the center of the star, very useful for misspointing
2579 studies.
2580
2581 - added support for multi-telescope camera files. Added classes
2582 MStereoCalc and MStereoPar, classes to calculate and store shower
2583 parameters calculated from the data of two telescopes, for the MC
2584 studies regarding the MAGIC clone.
2585
2586 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2587 MC data calibrated in photons instead of ADC counts.
2588
2589 - added three macros to show the calibration and analysis chain of
2590 MC data. The macro starmc.C does both calibration and analysis, producing
2591 an output containing Hillas parameters for each event. The macro
2592 mccalibrate.C does just the calibration and writes out a file containing
2593 pixel information in photons instead of FADC data. The macro starmc2.C
2594 reads in such a file and produces an output with Hillas parameters.
2595
2596 - added MPedPhotCalc to compute pedestals in units of photons, see
2597 macro pedphotcalc.C
2598
2599 - added all class to perform the calibration, see macro calibration.C
2600
2601 - added class MFFT to perform Fast Fourier Transforms
2602
2603 - added class MSimulatedAnnealing to perform simulated annealing
2604 minimizations
2605
2606 - added new macro bootcampstandardanalysis.C which holds the skeleton
2607 of the analysis chain discussed in the december bootcamp.
2608
2609 - added support for DAQ raw data file format V2
2610
2611 - implemented an arbitrary time stamp for the events from raw-data
2612 files with file version<3. It is calculated from the run number,
2613 the date of start and the FADC clock tick from the first module
2614
2615 - implemented the correct decoding of the event time-stamp
2616 coming from the DAQ for raw-data files with file-version>2
2617
2618 - added a new classes storing the pedestals in units of photons:
2619 MPedPhotPix, MPedPhotCam
2620
2621 - added support for DC current files from the camera control
2622
2623 - added support for start- and stop-time when merpping report files
2624
2625 - added MReportCC storing the weather data from the CC-REPORT
2626
2627 - added class to fill trainings and test matrices (MTFillMatrix)
2628
2629 - added a filter performing a software trigger (MFSoftwareTrigger)
2630
2631 - Added classes to perform parts of the standard analysis (Jobs):
2632 + MJPedestals
2633 + MJCalibration
2634 + MJExtractSignal
2635 Note: All of them are preliminary!
2636
2637 - Added Iterator to iterate over files giving only the run-number
2638
2639 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2640 the evolution of a sector vs time
2641
2642
2643
2644 *** Version 0.8.3 (2003/12/05)
2645
2646 - adapted Random Forest classes to allow the use with MC
2647 multi-telescope files which can be produced with the coming
2648 camera version 0.7.
2649
2650 - added classes to read and interprete central control report files
2651 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2652
2653 - enhanced merpp (the executable) to support .raw and .rep files.
2654
2655 - added classes for light calibration (MCalibration* and
2656 MHCalibration*) by Markus Gaug. Further work has to be and will
2657 be done soon.
2658
2659 - Added a preliminary 'synchronizer' (MReadReports) which will
2660 replace MReadMarsFile as soon as it is finished.
2661
2662 - Added a tutorial macro demonstrating how report files are merpped
2663 and how they can be read from the root file in the correct order
2664 of time (readrep.C)
2665
2666 - Added a generalized histogram (similar to MH3) called MVsTime
2667 which allows to plot variables (or rules - MDataChain - of
2668 variables) vs time. For an example have a look at tempvstime.C.
2669
2670 - Changed the name of the event trees:
2671 + Events --> Events
2672 + PedEvents --> Pedestals
2673 + CalEvents --> Calibration
2674
2675 - changed name of MTime in the event trees from MRawEvtTime to MTime
2676
2677 - added displaying the sector indices to the mars event display
2678
2679 - Magic Online Analysis (MOnA) implemented in a first version
2680 (see mona.cc, MOnlineDump and MOnlineDisplay)
2681
2682 - added classes to calculate event rate
2683 (preliminary: MEventRateCalc, MEventRate)
2684
2685 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2686
2687 - added classes dealing with the telescope pointing position (MPointing*)
2688
2689 - implemented the 'final' Mars time stamp based on some experiences with
2690 the new 'Synchonizer'
2691
2692
2693
2694 *** Version 0.8.2 (2003/11/10)
2695
2696 - accelerated standard analysis by a factor of 6-8 ...
2697 + doing precalculations in MGeomCam for the pixel area ratio
2698 + creating a look up table for the single pixels in MCerPhotEvt
2699
2700 - added task to calculates weights in case you want to 'change'
2701 the energy spectrum of a monte carlo file
2702 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2703
2704 - added a new executable star which implements the
2705 star.C macro as precompiled executable. Currently a flexible
2706 setup is not possible, but a 'input card' setup will follow.
2707
2708 - Starting to implement Multi-Telescope-Support based on the
2709 upcomming camera version 0.7. The base for a general support
2710 is implemented and the star-functionality is proven to work.
2711
2712 - Replaced Event-Display in and Camera-Display in the Mars GUI
2713 executable by a more convinient display base on MStatusDisplay.
2714
2715 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2716
2717
2718
2719 *** Version 0.8.1 (2003/10/20)
2720
2721 - added signal subtraction for pure on data by means of fitting
2722 the background in the off region or by performing a combined
2723 signal/background fit. Provides necessary histograms for
2724 obtaining energy spectra and a light curve.
2725
2726 - added classes to perform and study the selection of the
2727 2nd Level Trigger on MC data (example in triglvl2.C macro)
2728
2729 - added pedestal calculation
2730
2731 - implemented "democratic cleaning" (tail cut value proportional
2732 to pixel area) according to Wolfgang's suggestion.
2733
2734 - added Sigmabar treatment (calculation and basic histogramming)
2735
2736 - added basic routines to apply padding
2737
2738 - added first implementation of MARS-based source visibility plotter
2739 (needs to be linked against slalib, preliminary version)
2740
2741 - enhanced functionality of data chains: random numbers, conversion
2742 functions and access to MHMatrix objects
2743
2744 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2745 numbers under certain circumstances (runs with 0 events included)
2746
2747 - fixed a bug in the general filter MF (didn't work on some systems
2748 at all)
2749
2750 - fixed a bug in chaining files, which caused the analysis to crash or
2751 ignore files
2752
2753 - implemented more geometry classes describing the parameters used
2754 to simulate the PMT camera
2755
2756 - added new Monte Carlo classes containing the setup of the different
2757 programs in the MC chain.
2758
2759 - added a (preliminary) general task to evaluate chi-square of a given
2760 parameter in an eventloop.
2761
2762 - first implementation of a container describing the observatory
2763 location (Long, Lat, etc)
2764
2765 - added Random Forest - method for g/h-separation
2766
2767 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2768 (this means, that it is compiling, but not yet fully tested)
2769
2770 - added a new status display which can show the present status
2771 of histograms while an eventloop is running (MStatusDisplay,
2772 an example can be found at status.C)
2773
2774 - reorganized directories:
2775 classes describing the image --> mimage
2776 classes containing Monte Carlo Histograms --> mhistmc
2777 classes for Random Forest method --> mranforest
2778
2779 - added (event-)weights to fill histograms
2780
2781 - colors in logging output to screen
2782
2783 - changes to the Image Parameter declaration:
2784 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2785 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2786 + MHillasExt now derives from MParContainer instead of MHillas
2787 --> Files written with the old definition are more or less unreadable
2788
2789 - reading of reflector files
2790
2791 - display data from reflector files in the camera
2792
2793 - implemented currents (and display them in the camera)
2794
2795 - logarithmic scale in camera
2796
2797 - added class to iterate through directory contents (MDirIter)
2798
2799
2800
2801 *** Version 0.8 (2002/11/18)
2802
2803 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2804
2805 - corrected 48(!) wrong entries in the Next Neighbor table of the
2806 Magic Camera (all in the inner part of the outer ring, mostly
2807 missing a single NN)
2808
2809 - Fixed a bug in the table describing the Next Neighbours of the
2810 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2811 have any neighbour)
2812
2813 - changed trigrate.C: now it calculates the pure NSB triggers from
2814 a camera file (generated with no showers), so there is no need
2815 to introduce them by hand in the BgR array (for more details
2816 please ask Abelardo)
2817
2818 - added MHHadronness (and MHadronness) as a general facility to evaluate
2819 the quality of a gamma-hadron seperation method
2820
2821 - changed MWriteAsciiFile to accept rules (MDataChain)
2822
2823 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2824 must be replaced by calles to MWriteAsciiFile::AddColumn and
2825 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2826 changed.
2827
2828 - Implemented generalized event-matrices (one row per event)
2829 (MHMatrix)
2830
2831 - implemented the one dimensional composite probabilities
2832 (MHCompProb, MCompProbCalc, comprob.C)
2833
2834 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2835 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2836
2837 - Added a camera display displaying the pixel numbers to the
2838 event display gui.
2839
2840 - Added Monte Carlo Informations to event display gui
2841
2842 - Changed the camera display to display the pixel numbering
2843
2844 - Added three buttons to the camera display to change the palette
2845
2846 - Added the number of used and core pixels after image cleaning
2847 to MHillas
2848
2849 - Changed the algorithm used in MHillas according to TDAS 02-03
2850
2851 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2852
2853 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2854
2855 - Added fCosDeltaAlpha to MHillasSrc
2856
2857 - The numbers of photons used to calculate fConc and fConc1 in
2858 MHillasExt are now scaled with the pixel size, so that one get
2859 a four times smaller value for the bigger pixels in the outer ring.
2860
2861 - added new task to smooth the camera contents (MCameraSmooth)
2862
2863 - added possibility to use interpolated pixel values for blind pixels
2864 instead of removing it completely from the analysis
2865
2866 - Implemented the possibility to save the whole eventloop with
2867 its setup to a file. This information can be read and from
2868 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2869 and MEvtLoop::MakeMacro. If you find something not working, please
2870 report - this stuff is still in a beta phase.
2871
2872 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2873 file having crab starfield, but also for all following files - fixed
2874
2875 - MTaskList::PrintStatistics can now be instructud to print also the
2876 title, too: use PrintStatistics(0, kTRUE)
2877
2878 - Changed the image cleaning so that pixels with to many 'used'
2879 neighbors are left used (to get rid of 'holes' in events)
2880
2881 - Introduced more output to the camera displays
2882
2883 - Added an array of histograms (eg one hist per run), MHArray
2884
2885 - Added a _preliminary_ version of the reader for CT1 PreProc files
2886 (MCT1ReadPreProc)
2887
2888 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2889 (thanks to Raquel)
2890
2891 - added the first energy estimator (MEnergyEstParam, estimate.C,
2892 estfit.C) using a parametrization
2893
2894 - Added some new Monte Carlo paremeter containers used to store
2895 setup information from the MC chain (MMcConfigRunHeader,
2896 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2897
2898
2899
2900 *** Version 0.7 (2002/04/30)
2901
2902 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2903 the pedestal mean value was saved incorrectly. For files from
2904 this versions we substract 0.5 from the pedestal mean.
2905 WARNING: This may effect your results, so don't wonder...
2906
2907 - First implementation of an algorithm using only triggered events
2908 for the collection area calculation
2909
2910 - Ascii Output can now also be used for parameter containers which
2911 doesn't overload MParCointainer::AsciiWrite
2912
2913 - The Ascii Output is now also capable of writing single data members
2914 of one container
2915
2916 - You are now able to change the order of the values written to the
2917 ascii file
2918
2919 - You can now specify a conversion factor for each data member written
2920 to an ascii file. This may be usefull to change the units of the
2921 data member (eg. degrees instead of millimeters in case of the
2922 hillas parameters)
2923
2924 - Replaced old MHillas by a new structure which allows you to extend
2925 the parameters stored in MHillas very easily:
2926 see MHillas and MHillasExt
2927
2928 - Added classes to handle source dependancy of image parameters:
2929 see MHillasSrc
2930
2931 - Added container (MBinning) to have a standard input for the binning
2932 in different histograms (eg. the Energy bins should be the same in
2933 all histograms)
2934
2935 - Changed Hillas histograms from mm to deg
2936
2937 - Added the flexible binning to the hillas histograms
2938
2939 - Added a filter for the alpha parameter (MFAlpha)
2940
2941 - It is now possible to write single data members of a class object to
2942 an output stream instead of the whole container only
2943
2944 - Added a generalized filter for a data member:
2945 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2946
2947 - Added a generalized Filter parser for more difficult filter rules
2948 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2949
2950 - Added new Monte Carlo histograms:
2951 MHMcEnergyImpact and MHMcEfficiency
2952
2953 - Added many new histograms needed for the flux calculation.
2954
2955 - Added a generalized histograms which can fill and show up to three
2956 data members in either a one-, two- or three-dimensional histogram, eg:
2957 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2958
2959 - Added:
2960 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2961 * calculation of <Theta> as a function of time (MHThetabarTime)
2962 they are needed in the flux calculation in
2963 order to select for a given bin in Theta (or time) the appropriate
2964 effective collection area, which is assumed to be given as a function
2965 of Theta and the true energy
2966
2967 - Added calculation of the migration matrix in the energy
2968 (MHMcEnergyMigration):
2969 the migration matrix describes the migration from the true (E_true)
2970 to the estimated energy (E_est); it is needed to determine the
2971 distribution of E_true from the measured distribution of E_est
2972 by unfolding
2973
2974 - changed the color palette in the camera display to DeapSea.
2975
2976
2977
2978 *** Version 0.6 (2002/01/15)
2979
2980 - Introduce the option of disable pixels (MBlindPixels and
2981 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2982 able to deal with Star Field NSB.
2983
2984 - Fixed a bug in the pedestals substraction
2985
2986 - Introduced verbosity levels
2987
2988 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2989
2990 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2991 work correctly (thanks to Abelardo)
2992
2993 - Introduced correct treatment of the diffuse Night Sky Background
2994 and NSB (MMcPedestalNSB)
2995
2996 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2997
2998 - Introduced MMcRunHeaders which contains monte carlo run informations
2999
3000 - Added a 'Print'-Task (MPrint) which calls the Print function
3001 of a parameter container for each event
3002
3003 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3004
3005 - changes to be more efficient with root 3.02/06
3006
3007 - root 3.02/06 fixes:
3008 + the memory leak when reading MRawEvtData
3009 + loosing more time than necessary to update the progress bar
3010
3011 - MWriteAsciiFile is now capable of writing more than one container
3012 in a line. For example: To be able to write Monte Carlo and
3013 Hillas values (energy and alpha) in one line.
3014
3015
3016
3017 *** Version 0.5 (2001/11/06)
3018
3019 - Added new GUI functionality (Analysis)
3020
3021 - Added a camera display to be able to display events in the camera
3022 together with the calculated hillas ellipse
3023
3024 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3025 object at any state of the analysis, so that the output are several
3026 states
3027
3028 - Fixed a bug in the collection area error calculation
3029 (Thanks to Ciro and Abelardo)
3030
3031 - Fixed a bug which causes merpp to crash in some environments
3032
3033 - Implemented auto enabling scheme for Branches to speed up reading
3034 a lot (see MReadTree and MTask)
3035
3036 - Fixed a bug in the Histogram classes which caused histograms to
3037 be written to a file by MWriteRootFile without request
3038
3039 - changed the object I/O from the old stylish root I/O to the new
3040 'auto evolution scheme' This was done only for classes which are not
3041 yet used in Monte Carlo files, so that these files are still readable.
3042
3043 - Added support for a progress bar in MEvtLoop and MReadTree
3044 (see the Analysis Window in Mars for an example)
3045
3046 - Fixed a bug in the package creation which disturbed the conversion
3047 between a mars version unpacked from a tar file and the repository.
3048
3049 - Changed the code to writer merpped (converted into root format)
3050 raw files, to get faster (around 10%)
3051
3052
3053
3054 *** Version 0.4 (2001/09/20)
3055
3056 - This release is made to compile on a root version >= 3.00
3057
3058 - Fixed a bug which causes MReadTree to read the first file only
3059
3060 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3061
3062 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3063
3064 - Added a task to write several container to a root file (MWriteRootFile)
3065
3066 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3067
3068 - Added calculation of the collection area (MMcCollectionAreaCalc)
3069
3070 - fixed some bugs in the Hillas calculation
3071
3072 - added filters to be able to control the task execution dependent on
3073 a parameter (for example: the number of level 1 triggers in a MC-file)
3074
3075
3076
3077 *** Version 0.3 (2001/04/23)
3078
3079 - Many demo macros added
3080
3081 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3082
3083 - Hillas Calculation added
3084
3085 - Standard image cleaning available
3086
3087 - MReadTree is now able to handle more than one file
3088 (Remark: of the same structure)
3089
3090 - Now we are able to display events in a first version of the
3091 Camera event display. To do this we must run the macro
3092 "macros/readCT1.C" to read data from CT1.
3093
3094
3095
3096 *** Version 0.2 (2001/01/24)
3097
3098 - First Implementation of a Gui to read the raw data. Start the
3099 gui with the command mars.
3100
3101
3102
3103 *** Version 0.1 (2000/12/20)
3104
3105 - First official release 0.1
3106
3107 - Changes:
3108
3109 + changed calling style of MRawPixelIterator from do...while to
3110 while-loop
Note: See TracBrowser for help on using the repository browser.