source: trunk/MagicSoft/Mars/NEWS@ 9281

Last change on this file since 9281 was 9281, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 127.6 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * This release doesn't contain a major change which is expected to
8 change your results. Nevertheless there are small changes to
9 the calibration which can effect at least the first few hundred
10 events in any (mainly MUX and even more SUM) sequence a little bit.
11 So it is recommended although not necessary to reset your sequences
12 in the database before further processing.
13
14 ;NEW
15
16 * A first implementation of a Monte Carlo simulation program
17 (ceres - Camera Electronics and REflector Simulation) has been
18 implemented. It can simulate a full telescope already including
19 a complete reflector simulation and a flexible trigger and readout
20 simulation. Currently, no perfect setup is implemented and
21 especially the output of the program (data structure) should
22 be considered alpha state. Also the user interface is not yet
23 ready.
24
25 ;general
26
27 * All command line options after -- are now interpreted as
28 arguments (usually everything which doesn't start with a minus)
29 rather than options (usually everything which starts with a
30 minus). This allows to use file names starting with a -
31
32 * In all resource files you can now initialize the random number
33 generator. For details see: MJob::InitRandomNumberGenerator
34
35 * added a new program called ''readcorsika''. It's purpose is (in analogy
36 to readraw and readdaq) to read a Corsika output file (for now
37 only cherenkov output is supported) and print its contents in a
38 human readable form. It can also write the contents of this file
39 into a root-file.
40
41 * The calculation of the maximum distance to the origin in a MGeomCam
42 has been improved (edges might be further away than the sides).
43 This is just a tiny change but it might change the appearance of
44 the radial profiles a little bit.
45
46 * The default binning of the center-of-gravity plot has slightly been
47 increased
48
49 ;Database
50
51 * Added informations about the DC currents (fMinCurrents, fMedCurrents
52 and fMaxCurrents). The values are retrieved from the plots showing
53 the average DC currents of all pixels versus time.
54
55 * Websites with tables have now the opportunity to remove lines
56 ('-' button at beginning of each line) and get all lines back
57 ('+' at top of the column)
58
59 * Websites: added option to query only sequences containing sumtrigger
60 events
61
62 * Websites: added option to group by date (year, month, night) for runs
63 and sequences and enabled that combining of different group-bys,
64 e.g. status, date and source is possible
65
66 ;automatic analyis
67
68 * Rewritten producing plots in the web.
69 New plots, namely the output of plotoptical.C (extinction curve from
70 KVA), plotstat.C (status of the automatic analysis (percentage of
71 processed, analysed data etc.)) and plotusage.C (statistics of the
72 condor usage in the data center) has been are available now next to the
73 plots of plotdb.C
74 Mean values from the plots (output of the macro) are provided in a
75 txt file now.
76 The creation of the plots for callisto, star and ganymed in the web is
77 now steered via database. Consequently the plots are faster and
78 reliable up-to-date.
79 For all plots, a new layout is available facilitating the browsing
80 through the plots and providing additional information on the
81 displayed values. (tabs.php) These plots are linked from the DB
82 websites and the wiki.
83
84 ;statusdisplay
85
86 * The ''Loop'' entry in the menu bar now contains an option to pause
87 the loop and to process single events.
88
89 ;merpp
90
91 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
92 instead of RunHeaders)
93
94 * Now allows to merpp files newer than 2008/09/03.
95
96 * Added fixes for wrong (wrong or double) run- and file-numbers
97 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
98
99 ;callisto
100
101 * Extracting the pulse position for the pulse position check events
102 with sum trigger were denied. This decreased the statistics
103 extremely and therefor the resulting puse position was calculated
104 quite weak. Now sum events pass the calculation if and only if they
105 have also a level 1 trigger.
106
107 * the extraction of pedestal events and pulse position from the
108 first data events is now more automatic and makes sure that
109 a more precise number of events is extracted independent of
110 the ratio with which pedestal events or events with signals
111 are contained in the data.
112
113 ;star
114
115 * For the calculation of the effective on time all sum-triggered events
116 were skipped. Now all Level1-triggeres events will pass. This might
117 result in a slight inaccuracy of the effective on time.
118
119 ;ganymed
120
121 * If the source position is more than 1deg away from the camera
122 center an error is raised now.
123
124 * Hopefully fixed the bug ''ganymed crashes when resized''
125
126 ;sponde
127
128 * Fixed a problem which causes the fitted spectral slope to be displayed
129 incorrectly. If you use MJSpectrum::FormFlux in your macros make
130 sure that the parameter 0 of your fit is negative.
131
132 * Added a histogram showing the read source position of your MCs
133
134
135
136== Version 2.1.1 (2008/08/04) ==
137
138 ;Database
139
140 * Added the median number of photo electrons from the calibration
141 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
142 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
143
144 * Added fTotOnTime, which is the on-time as given by the run-headers
145 (in contradiction to fAbsOnTime which comes from CC)
146
147 * Added new primaries for the new data structure (Magic II): for the
148 tables dealing with sequences (SequenceBuild Status, Sequences,
149 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
150 this is the telescope number (fTelescopeNumber) for the tables dealing
151 with runs (RunData and RunProcessStatus) this is in addition the file
152 number (fFileNumber)
153
154 * Added column fPriority to the status tables to be able to steer the order
155 in which the data is processed. As default the run, sequence and dataset
156 number are used.
157
158 ;automatic analyis
159
160 * Adapted scripts to the new data structure: They can handle now different
161 telescopes (getting the information as usual from the database).
162 The paths for Magic 2 are not yet implemented.
163
164 ;general
165
166 * should work now with root 5.20/00 (please note that root 5.20/00
167 we encounter crahses in the status display which are ot yet
168 understood)
169
170 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
171 instead of the base name of the file. This makes them easier to
172 access from the code
173
174 * Default Monte Carlo names in MSequence do not require the _E at
175 the end anymore
176
177 * where abrrevating a sequence file with a sequence number is possible
178 also "telescope:sequence" is now accepted, e.g.:
179 star 2:2000123 --out=output
180 see the programs' help for more details.
181
182 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
183 from the database. See the constructors for more details.
184
185 * MReadTree now supports friends
186
187 * MReadTree can now read also files not written by MARS and store
188 the data encapsulated in emulated MParContainers
189
190 * added a new starguider calibration valid since 15.1.08
191
192 ;showplot
193
194 * showplot can now read more than one file at once. This is especially
195 inetersting if reading files containing pure canvases
196
197 ;merpp
198
199 * we merpp the dc currents now also from the camera reports (they have
200 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
201
202 * In the automatic analysis we omit merpping of the currents from the
203 caco files and use the lower rate camera reports from the cc files
204 instead
205
206 * merpp has been redisigned to allow merpping of the cc-reports
207 of a whole sequence. This allows to design a very simple analysis:
208 mkdir output
209 ./callisto 100776 --out=output
210 ./merpp 100776 output
211 ./star 100776 --ind=output --out=output
212 Instead of the sequence number also sequence files are accepted.
213
214 * Implemented a fix for run-numbers between 1001348 and 1001396
215 which were incorrectly assigned by the cc.
216
217
218 ;callisto
219
220 * added a filter again which was was removed in the last release.
221 it removed the most brightest events. This should not change
222 any analysis result because these events are so bright that
223 they cannot be analysed anyway, but the bad-pixel plots doesn't
224 show outliers.
225
226 * updated muon calibration constants for the periods 51-57,
227 58-63 and 67-
228
229 ;star
230
231 * The camera currents are now displayed with the rate of the camera
232 reports instead of the caco reports
233
234 ;ganymed
235
236 * if mc camera files are new enough (>=8) the source position in the
237 camera is now calculated from the stored telscope and shower
238 orientation (Note, that this might not be suitable in all cases
239 depending on the aim of the study. These case still needs
240 implementation)
241
242
243
244== Version 2.1 (2008/06/18) ==
245
246 ;Database
247
248 * introduced average temperature and wind speed from star-files
249
250 * introduced average values from Pyrometer (mainly Cloudiness)
251
252 * introduced the ratio of accepted calibration events in the
253 calibration run
254
255 * introduced the average rates of the different trigger pattern,
256 e.g. the rate of pedestal and calibration events, from the signal-file
257
258 ;general
259
260 * fixed GroupBy options in plot*.C macros
261
262 * only display KVA points (not the Tuorla points) in plotoptical.C
263
264 * all programs now allow to add resources to the ones from the resource
265 file or overwrite them from the command line. This can be done like this
266 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
267 if something seems to be wrong you can debug what the program is doing
268 using the option --debug-env=3
269
270 * increased the diversity of debug levels. That also means that with -v3
271 you get now less output, i.e. only the output which is important for
272 an analysis. To get more output which helps for debugging try 4, 5 and 6.
273
274 * fixed a problem in the task synchronizing the reading of the reports
275 and the data stream. The effect was that in some circumstances the last
276 events of some trees could have been skipped. Since this is only a
277 very tiny part of the data no severe effect to your analysis results
278 is expected (an exception might be very short, i.e. singel runs,
279 datasets).
280
281 * Dataset file now allow to include the sequence file directly within
282 the dataset file and also allow to exclude single runs from the dataset.
283 (for more details see Class reference of MDataSet)
284
285 * Sequence files now allow for excluding runs from the analysis
286 (for more details see Class reference of MSequence)
287
288 * added code to process the sum-trigger flag
289
290 * the histogram classes MH3 and MHn now support profile histograms
291
292 * the histogram classes MH3 and MHn now support labels at the axis
293
294 * the Random Forest Train-classes (MJTRain*) now store the used datasets
295 in the output file
296
297 * the MFMagicCuts have a new option to allow a linear area cut (for
298 special studies)
299
300 * The liniking of the shared object is now done into a file defined
301 by 'mktemp'. This should be a local file system which accelerates
302 liniking a lot.
303
304 * The code has been prepared for compilation with root 5.18/00d
305
306 * The MHEnergyEst histogram now shows the distribution of
307 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
308 and (Eest-Emc)/Emc vs Emc.
309
310 * fixed mars (event display) for merpped raw-data and MC data
311
312 * adapted the synatx of sequence files to allow for the new run/file
313 scheme. For more details see class description of MSequence
314
315 ;showplot
316
317 * Added support for tiff files
318
319 * Added support for csv files (tables containing tab number,
320 name and title)
321
322 * Tabs now can have a title which is displayed in the postscript file
323
324 * When multiple file are written at once (e.g. pngs from a display)
325 it is now possible to use the tab name and or tab number in the
326 file name. For details see showplos's help.
327
328 ;merpp
329
330 * Implemented cc file version 2008-02-20/0
331
332 * Implemented cc file version 2008-05-19/0
333
334 * With new options merpping can be restricted (in addition to the
335 run-number) also by telescope and file number.
336 For details see "merpp --help"
337
338 * Implemented raw data format 11 (the most important change, except
339 from plenty of changes in the format definition, is the addition
340 of the file-number in the header) If nobody makes a mistake this
341 format should have the advantage that it is by definition forward
342 compatible, so old programs will be able to read newer formats.
343
344 * Added Pyrometer information to default output (stored in a new Tree
345 Pyrometer, needs a complete new merpp, i.e. new calibration)
346
347 * Merpping (also update) can now be restricted to one single report.
348 For example:
349 If you want to update an old file with Pyrometer information call
350 merpp --only=Pyrometer --update
351
352 ;callisto
353
354 * in the pedestal processing now at least 50 processed events are
355 required for succeeding.
356
357 * the signal and calib files now contain also the sequence information
358
359 * the two MPedestalCam in the calib file now have proper names
360 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
361
362 * Both pedestal cams now contain the number of events processed
363
364 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
365 i.e. for the extraction of the calibration pulses basically the average
366 over all events of the first slice instead of all slices was used.
367 Since pedestal and calibration constants are continously recalculated
368 this only effected the very first events of every sequence.
369
370 * For the extraction of the position of the maximum sample now the
371 extraction range is set automatically to the extraction window,
372 before the whole accessible range was used.
373
374 * If the number of samples in the events and the number of samples
375 in the run-header disagrees now an error is raised (this can
376 happen in not well simulated Monte Carlo files)
377
378 * In the case of MUX-data pedestal events with the lvl1 trigger flag
379 could survive into the pedestal calculation -- fixed.
380
381 * Tab "TrigPat" added showing the distribution of the trigger pattern
382 as found in the run-files (normalized with the run length)
383
384 * The selection of events from the trigger pattern has been improved.
385 If the trigger pattern is corrupted events won't pass anymore.
386
387 * Added a new command line option --dev-null to suppress output of
388 Y-files (this is useful for test cases)
389
390 * added a new tab "CalPos" showing the arrival time of extracted
391 interleaved calibration events
392
393 ;star
394
395 * the star file now contains also the sequence information
396
397 * Added a new command line option --dev-null to suppress output of
398 I-files (this is useful for test cases)
399
400 * Tab "Rate" added showing the distribution of the trigger pattern
401 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
402 the Y-files (normalized with the run length)
403
404 * The effective on-time calculation doesn't use events with only
405 sum-trigger anymore
406
407 * The data in the MHWeather tab has been reorganized. The never
408 working solar radiation has been removed and the data from
409 the pyrometer (cloudiness, air and sky temperature) is
410 displayed in addition.
411
412 ;ganymed/sponde
413
414 * Now data points are even shown correctly if they have error bars larger
415 than one sigma. Points with null or negative significances are omitted.
416
417 * DrawNicePlot now allows to set a projection range
418
419 * Updates pointing models. One is applied after the implementation
420 of the new LUTS in August, the other one is applied after the
421 next major change of the pointing model in October. Note that
422 these models are preliminary and give wrong results below Zd=65deg
423
424 ;sponde
425
426 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
427
428 * a new option "--force-runtime" is available. In case of very short
429 datasets (for light-curves) which are in the order of a few
430 minutes the calculated effective on-time is not very acurate because
431 it is quantizised in the order of a minute. Therefore you can switch
432 to using the real run-time instead (remakrt: this ignores any
433 dead-time!)
434
435 * a more analytical way is used to "fill" Monte Carlos into regions
436 of impact parameters which have not been simulated because the
437 trigger efficiency is assumed to be 0.
438
439 * estimated sensitivity curves for hi and lo zenith angles are shown
440 scaled to the correct observation time and collection area
441
442 * the Monte Carlo events after cuts are now written to the output file
443 if an output file given
444
445
446
447 *** Version 2.0 (2007/09/03)
448
449 - database: the position used for the pulse pos check was missing
450 in the callisto output and could thus not be filled into the DB.
451 Also the old values seemed not exactly the PulsePos used for
452 teh check.
453
454 - general: Resource file now allow an Include-Resource, i.e. you can
455 read a resource file with default settings, include it in your
456 resource file and overwrite the settings in your file. More than
457 one include file is allowed. Inclusions can be iterative.
458 Include: mydefaults.rc yourdefaults.rc
459 The resources in the first file have higher priority than the
460 second file.
461
462 - general: Now the output files (calib*.root, etc) also contain the
463 resource file (to check it open it in the TBrowser and choose Print()
464 from the context menu)
465
466 - general: Dataset files now allow to overwrite the default path
467 to search for sequence and data files. Note, that the program
468 option and individual resources will overwrite it. For example:
469 SequencePath: /magic/montecarlo/sequences
470 DataPath: /magic/montecarlo/star
471
472 - general: Fixed a problem with variables in MDataPhrase. It seems
473 that only optimdisp (didn't work) was effected.
474
475 - general: Some improvements to the optim and train processing. For
476 example the ststud window now got a proper title.
477
478 - general: The "Status Display: " was removed from the window title
479 within an Eventloop.
480
481 - general: added a new flexible histogram-class (MHn) which can be used
482 for example in testing after optimizations or training to produce
483 user defined histograms.
484
485 - general: The Random Forest now allows attaching an evaluation
486 function which is applied to its output. This allows to train
487 on whatever you like (eg. train on log10(energy), but return
488 energy)
489
490 - general: The Random Forest training of energy (trainenergy.c) and
491 disp (traindisp.C) has been improved by more graphical output to
492 judge the result.
493
494 - general: The training of energy (trainenergy.C) has been improved
495 a lot by training on a different quantity than energy. It gives
496 a result which is highly independant of the source spectrum
497 and shows lower bias than all other options.
498
499 - general: Dataset files are allowed to contain collections of
500 datasets. For more details see the class reference of MDataSet.
501
502 - general: The default WobbleMode in a datset file now (if not
503 overwritten) is "auto", i.e. wobble mode is set if the dataset
504 doesn't contain off-sequences.
505
506 - merpp: Merpp can read file format version 9 now. Please realize
507 that for file format version 9 the extraction range is different
508 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
509 the first and last 15 slices have been removed from all MUX data.
510
511 - mars: Similar to writing movies you can now select events which
512 should be displayed in your display. Therefore add the following
513 lines to your mars.rc:
514 MFEvtNumber.FileName: ganymed00223552.root
515 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
516 The input file can be a ganymed-file after (ganymed*.root) or
517 before (ganymed*-summary.root) file. For example to select all events
518 from your on sample after cuts (excluding the ThetaSq cut) use
519 MFEvtNumber.Selector: DataType.fVal>0.5
520 To show all events from your on-sample after quality cuts
521 use the summary file instead.
522
523 - mars: new ways to call mars are implemented. Instead
524 of calling
525 mars filename.root
526 you can now also use
527 mars sequence.txt
528 or
529 mars sequence.txt inputpath
530 or replace sequence.txt by the sequence number if the default
531 sequence file should be used.
532
533 - mars: The default size has been increased
534
535 - mars: There are two new heckboxes which allow to switch off
536 the calculated image parameters
537
538 - callisto: was broken for MCs... fixed.
539
540 - callisto: improved calculation of spline coefficients a lot. This
541 leads to a further improvement of the event rate calibrating MUX
542 data of about 15% (175evt/s instead of 150evt/s)
543
544 - callisto: finally the raw data we read is now real 16bit (with
545 10bit precision) for MUX data and not a stripped 8bit number
546 anymore. Due to scaling of the numbers (without precision loss
547 into an [0-256[ range, the final numbers for pedestal, pedestalrms
548 and extacted signal don't change. However, at all places where
549 raw data is directly accessed (eg. saturation and variation
550 limits in the signal- and pedestal-extraction) the numbers
551 refer still to the data's 16bit range.
552
553 - callisto: The maximum arrival time difference used in the bad
554 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
555 for both, old FADC and MUX-FADC, data.
556
557 - callisto: Be aware that callisto is now calibrating the arrival time
558 in nanoseconds rather than time slices. Also all following tasks
559 have been changed to assume ns units now. If you star data
560 calibrated with an older version it might be necessary to adapt
561 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
562 to obtain optimal results. The plot in the PulsePos tab
563 will now be in ns, too. This might also mean that the Muon
564 analysis in star might not work as perfect as expected as long
565 as old files read in.
566
567 - callisto: The calibration constants of earlier updates got lost
568 somehow. All constants have been updated.
569
570 - star: The PSF is now determined from the profile of the ArcWidth
571 instead of arcwidth/radius. The old way gave to much weight
572 to the bins with low statistics. The reference lines have been
573 updated.
574
575 - star: For speed reasons events suitable for the muon analysis
576 are now also preselected by fConcCOG<0.1 which seems to be a very
577 good preselector for muons.
578
579 - star: is now calculating a new timing parameter the Slope along
580 the major and minor axis of the shower. Therefore a numerical
581 solution of a line-fit is used. To use MHillasExt.fSlopeLong
582 and MHillasExt.fSlopeTrans don't forget to multiply it with
583 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
584
585 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
586 have been removed from MNewImagePar. They have never been good for
587 anything.
588
589 - star: Implemented a new recursive algorithm which is supposed to be
590 faster. Also implemented new cleaning oiptions, which are:
591 + CleanLevel0:
592 The cleaning level above single core pixels can be kept
593 + KeepIsolatedPixels:
594 Define whether single core pixels should be kept
595 + TimeLevel1:
596 The coincidence window in nanoseconds to single used neighbors
597 + TimeLevel2:
598 The coincidence window in nanoseconds to two used neighbors
599 + PostCleanType:
600 MOde in which a time dependent post cleaning should be applied
601 0: No post cleaning
602 1: Require for each used pixels at least one used neighbor
603 within a time-window of CleanLevel1
604 2: Require for each used pixels at least two used neighbor
605 within a time-window of CleanLevel2
606 3: Require first two and second one used neighbor
607 within a time-window of CleanLevel1 and fCleanLevel2
608 respectively
609 + RecoverIsolatedPixels:
610 - recoveres isolated core pixels if they have a used neighbor
611
612 - mars/star: The new default cleaning is:
613 + CleanLevel1: 6.0
614 + CleanLevel2: 3.0
615 + CleanTime1: 1.75
616 + CleanTime2: 1.75
617 + PostCleanType: 3
618
619 - star/ganymed: The old spark-cuts have been replaced by new ones.
620 These new spark cuts have been cross checked with the sequences
621 84720 (before splitter), 101041 (after splitter) and 223539 (new
622 FADCs). In all cases they seperate pretty well, but of course not
623 perfect. Monte Carlos have suggested to tighten the cuts a little
624 bit further at low sizes. This has been done.
625
626 - ganymed: IMPORTANT - The spark cuts have been changed to match
627 all available data more or less well. This might mean that for
628 YOUR data there are still sparks visible.
629 Whenever you do an analysis you have to make sure that NO sparks
630 survive your cuts!
631
632 - ganymed: The old hadronness and size cuts have gotten new indices
633 (10, 11). The old indices 8 and 9 now mean an additional condition
634 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
635 If you want to switch off this cut just move the line far away enough,
636 e.g. by setting c[9] to -500. Please update your ganymed.rc files
637 accordingly!
638 The unit of c[9] is deg. It is the dist at which your cut will
639 cross the slope==0. The unit of the slope is ns/deg. So if
640 you readin files calibrated with an older Mars-version you
641 have to adapt the default value for c[9] to the FADCs:
642 - Multiply by two for the MUX FADCs (run number > 200.000)
643 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
644 - Multiply by 42 for the meaning of life (run number = 200.000)
645
646 - ganymed: The old Cut0 is now called CutQ and is calculated before
647 the source position is caluclated. If you need a quality cut
648 including source dependant data (be very carefull with this!)
649 you have to use Cut0 instead.
650
651 - ganymed: now properly supports three off regions in wobble mode.
652 It will be the default from now on in ganymed_wobble.rc. To change
653 the number of off-regions use
654 NumOffSourcePositions: 1
655 in your ganymed.rc. Also by default no off-theta cut will be done
656 anymore so that you will get a background level higher than the
657 signal level in your ThetaSq plot for ThetaSq>0.2.
658 Due to this be carefull changing the scaling mode away from
659 "None". You will underestimate your signal if your scale interval
660 is not properly set.
661 (Rem: ThetaSqN is no longer needed)
662
663 - ganymed: is now storing the events of all (on- and off-)
664 source positions even in the case of more than one off-source
665 position. This should allow sponde to work properly and the
666 energy estimation is done correctly in all cases (without any
667 "nearest position" trick)
668
669 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
670 with a real pointing model for the starguider is done, calibrated
671 with more than thousand tpoints taken from this date on.
672
673 - ganymed: was broken for Wobble-MCs... fixed.
674
675 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
676 has changed. Note that your old ganymed.rc will be incompatible
677 with the new algorithms! Please check the ganymed.rc files and
678 the class description of MFMagicCuts for more information.
679 It is recommended at the moment to use identical Disp-Parametrizations
680 for on/off- and wobble-mode. If cuts are optimized only
681 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
682 should be optimized. All other values should be kept as they are.
683 If you want to do an anylsis without timing a parameters, you can
684 switch off the timing cuts by seeting parameter 7 to a very small
685 value (eg. -99). To remove the slope parameter from the disp
686 paremtrization set parameter 8 to 0.
687
688 - ganymed: The distribution of observation time versus zenith
689 angle is now shown for off- AND on-data.
690
691 - ganymed: The contents of the source position plot are no longer
692 averaged, thus a lot of (fake) events between the two wobble
693 positions have disappeared.
694
695 - ganymed: There is a new tab "CutT" it contains the VsSize plots
696 with the CutT, whihc is defined in ganymed.rc, applied. It
697 is resonable to use your theta-cut for it, to see if there is
698 something strange (sparks!) in your signal-region.
699
700 - ganymed: To choose a dataset from a collection in a dataset file
701 use the new command line option "--dataset=12345"
702
703 - optim, sponde: should now properly support three off-regions.
704 Just produce your ganymed summary files with three off-regions.
705 optim and sponde will automatically get all off events from
706 all off-regions from this file. Please do not forget to
707 set the scaling in optimwobble.C properly:
708 fit.SetScaleUser(1./3);
709 it is not yet read in automatically (will follow soon).
710 In the case of fixed Scale you can also use
711 cuts.SetThetaCut(MFMagicCuts::kOn);
712 no off-cut needed.
713 Be carefull in case of three off-regions when switching on
714 scale mode. Make sure that the scale interval is set correctly.
715
716 - sponde: sponde.rc and sponde_onoff.rc are now idetical
717
718 - sponde: the resouce files have been rewritten with a lot of
719 comments and a well working parametrization for an energy estimator
720
721 - sponde: In the estimated energy versus monte carlo energy plot the
722 contents where exchanged.... fixed.
723
724 - sponde: the so called "accurate"-mode has been removed. It didn't
725 give any improvement in accuracy, only decreased execution speed.
726
727 - sponde: the so called "simple"-mode has been removed. It didn't
728 give any improvement in simple.
729
730 - sponde: the so called "refill"-mode has been removed. It was anyhow
731 not implemented.
732
733 - sponde: now checks whether the theta distribution of your on-data
734 and the theta-distribution of your Monte Carlo sample (after
735 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
736 sample is incomplete) execution is stopped. Execution can be forced
737 using the new option --force-theta. Use this option with care!
738
739 - sponde: Proper collection areas can now be constructed also from
740 Monte Carlo samples generated with different maximum impact
741 parameters. Note that in previous version you neither got
742 a warning or failure, nor was there any obvious sign that the
743 collection area was overestimated due to usage of files with
744 different maximum impact parameters.
745
746 - sponde: If MC files with different lower energy limits are used
747 the primary MC spectrum is artificially completed down to the
748 lowest energy used at all. WARNING: that this gives correct
749 collection areas ONLY if none of the events in this region would
750 survive your cuts at all.
751
752 - sponde: the output file now contains more information about
753 the spectrum (eg. the full 2D collection area histogram).
754 Note, that this information can only be written to the file
755 if it is stored automatically via command line argument.
756 If you only store the status display from within the display
757 the information is lost.
758
759 - sponde: added a new tab "Disp". It shows the residual of the disp
760 (Disp-Dist) versus several parameters and it is meant to judge the
761 quality of the disp estimator. In the ideal case the residual is zero
762 and doesn't depend on any variable. The tab is displayed after
763 CutQ and Cut0.
764
765 - sponde: added a new tab "Energy". It shows the residual of the
766 energy (lg(estimated energy)-lg(monte carlo energy)) versus
767 several parameters and it is meant to judge the quality of the
768 energy estimator. In the ideal case the residual is zero
769 and doesn't depend on any variable. In reality even a good estimator
770 can show residuals versus Monte Carlo energy. The tab is displayed
771 after all cuts.
772
773 - sponde: added a new tab "EventDist" showing the unweighted real
774 absolute number of events of your sample after cuts. This tells
775 you how many events with this energy you had in your MC files.
776 The same information you get from the error bars of the weighted
777 histograms, but this is less intuitive.
778
779 - sponde: The spectrum plots now show the crab- and 1553-spectrum
780 for comparison. It is not meant to show these curves in
781 publications, they are only for production.
782
783 - sponde: The OriginalMC tree with the events produced by corsika
784 is now processed only once
785
786 - sponde: Finally fixed most annoying bug, which has effected the
787 last bin of the collection area. It was the problem that binnings
788 of root histograms are from 1 to n (included) but there was a C-like
789 loop in sponde from 0 to n (excluded). Now the loop also includes
790 correctly under- and overflow-bins. The worse thing with this is,
791 that for the events in the highest bin not only the bin-content
792 was wrong, but also the weights applied to these events, which could
793 in pricipal effect also other parts of the distribution (eg. due
794 to energy estimation). Fortunately it effected only a few events
795 in most cases.
796
797
798
799 *** Version 1.2 (2007/05/14)
800
801 - database: The database now has two new values Unsuitable50 and
802 Unsuitable01. They express the number of pixels which are
803 unsuitable for more than 50%, respectively more than 1%, of
804 all calibrated event. It is a more accurate number than the
805 previously used numbers, because they only take the first
806 calibration (ignoring the interleaved calibrations) into account.
807
808 - database: The database now has two other new values UnsuitableMax and
809 DeadMax. They express the maximum number of pixels which were
810 unsuitable, respectively dead, during the sequence. Because
811 of high pedestal rms (cars passing) a few events with very high
812 numbers of unsuitable pixels can happen. Not to suffer from this
813 effect we don't take the highest 0.1% of the numbers into account.
814
815 - general: fixed a bug which caused callisto and star to stop working
816 properly because the callisto output was currupted
817
818 - general: a script called scripts/makemovie has been added which
819 simplified the process of producing several movies from a single
820 sequence with different setup.
821
822 - callisto: Some more code cleanup. Started to remove old obsolete
823 code from cvs.
824
825 - callisto: The extraction of the pedestal with the extractor was
826 not random. It seems that extracting at one position is still biased
827 (for example in the first or last slices we could still suffer from
828 switching noise) Now it is completely random.
829
830 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
831 pedestal files) individual pixels could be skipped due to high
832 variations. This was already the case for the pedestal extraction
833 from the lo-gains since the beginning and properly handled
834 there, but was introduced in the extraction from the pedestal files
835 a while ago. To calculate the average value it was still divided
836 by the number of events procesed not by the number of summands
837 really summed. This let to a pedestal which was a tiny amount too
838 small (for a few piels in the order of 0.1%). This led to an slightly
839 positive offset of the randomly extracted pedestal for a few pixels.
840 I doubt that this has a big effect on the result, because the effect
841 on the individual numbers is quite small. Due to this it is suggested
842 that you rerun your calibration to make sure you are without any
843 avoidable bias.
844
845 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
846 the median rms of the absolute arrival time and expressed in significance
847 levels. This replaces the old meaning of an abolute upper limit. An
848 absolute upper limit doesn't make much sense, because in our data
849 all arrival times are shifted at the same time (in fact it might be
850 a shift of the artificial trigger w.r.t. to the light flash).
851
852 - callisto: Added a new tab "BadPixTm" which shows the time evolution
853 of the number of unsuitable pixels over the whole sequence. This
854 is usefull mainly to judge if an intermediate calibration had
855 problems.
856
857 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
858 of the number of dead pixels over the whole sequence. Dead pixels
859 in this context are unmapped pixels, i.e. pixels which could not
860 be interpolated, and thus are ignored in the further analysis.
861
862 - callisto: It is now possible to use the position of the maximum
863 of the spline as arrival time instead of the leading edge even
864 when using the integral for the signal. Therefor set the extraction
865 type to kIntegralRel ("IntegralRelative") and the relative height
866 ("HeightTm") to -1:
867 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
868 MJPedestalC1.ExtractSignal.HeightTm: -1
869
870
871
872
873 *** Version 1.1 (2007/04/27)
874
875 - general: The new class MGeomCamDwarf contains the camera geometry
876 for our prefered Dwarf camera and can be used to create general
877 geometries of roundish or hexagonal cameras.
878
879 - mars: The default cleaning is now abolute 8.5/4.0.
880
881 - mars: The resource file mars.rc now contains examples for MUX data
882
883 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
884 data containing only 10-bit information is still cooked down to
885 8-bit, by cutting away the lowest 8-bit.
886
887 - merpp: When reading raw data the data is now stored in a single
888 array. The lo-gain array is obsolete. The interface stays the same.
889
890 - callisto: To process the new MUX data use the resource file
891 callisto_mux.rc
892
893 - callisto: The -root and -raw options to read merpped raw data have
894 been removed
895
896 - callisto: If the -mc option is given the sequence-name can now be
897 replaced by the MC sequence number
898
899 - callisto: If the sequence file contains "MonteCarlo: Yes" the
900 -mc option can now be omitted
901
902 - callisto: Started further simplification by removing obsolete
903 dependancies on MCalibIntensity*Cams.
904
905 - callisto: removed unsused intensity calibration from MJCalibration
906 for further simplification
907
908 - callisto: for simplification removed references to
909 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
910 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
911 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
912 (this should at minimum change nothing at all, and at maximum
913 improve thing if these containers where somewhere not handled
914 properly)
915
916 - callisto: Added the option to write an event movie. Please use
917 this option with care (huge files) but exessively to understand
918 our events. For further documentation please refer to the
919 IACT wiki
920 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
921
922 - callisto: Improved binning for the pulse position check histogram
923
924 - callisto: The code calculating the pulse position checknow takes
925 the pedestal into account
926
927 - callisto: The arrival time is now stored with full precision this
928 helps to get rid of artefacts in histograms. For the signal this
929 is not necessray because it is displayed in log-scale anyhow
930
931 - callisto: Fixed a problem with internal exclusions. Pixels which
932 have once been marked as unsuitable didn't get the necessary
933 histograms filled anymore to be rechecked with each interleaved
934 calibration.
935
936 - callisto: The relative arrival time resolution (the rms of the
937 relative arrival time offset) is now checked against its
938 median and the median deviation, instead of the average
939 plus an absolute offset.
940
941 - callisto: The relative arrival time offset is now calculated
942 w.r.t. its median not w.r.t. to an artificial reference pixel.
943
944 - callisto: The relative time calibration now marks pixels with
945 outlaying offset as unsuitable
946
947 - callisto: The interleaved relative time calibration has been switched
948 on. The advantage is that pixels which are marked as outliers
949 now can recover. An improvement over time is not expected, because
950 the relative time calibration seems stable.
951
952 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
953 option can now be omitted.
954
955 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
956 or the option "-mc" is specified as default the monte carlo datacenter
957 paths (/magic/montecarlo/...) are used if not overwritten in the
958 dataset file.
959
960 - ganymed: The output files now contain run- and event-number for all
961 events, accessible as RunNumber.fVal and EvtNumber.fVal
962
963 - ganymed: Added a plot showing the source position in the camera also
964 for wobble mode
965
966 - ganymed: In addition to the existing task which can be setup to
967 be executed after Cut1 a final task called "EstimateEnergy"
968 has been added, executed before writing the final output
969 (ganymed00000000.root). The task setup in all three cases
970 can be choosen individually. (For all three(!) cases you
971 can for example choose MRanForestCalc. For examples see all
972 sponde*.rc and all ganymed*rc)
973
974 - ganymed: If a container "MEstimatedEnergy" is found in the
975 parameter list (eg. because it was setup by MEstimateEnergy)
976 it will be written to the output file.
977
978
979
980 *** Version 1.0 (2007/02/16)
981
982 - database: Website to plot values from the database has been added.
983
984 - database: The rate of spark events as found by star is now kept
985 and the rate after cleaning is now with spark events subtracted
986
987 - general: The changes to the interpretation of phrases lead to
988 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
989
990 - general: Added example files how you can create your own calendar
991 (eg. as christmas present) with Mars. Just run
992 root macros/tutorials/calendar.C
993
994 - general: Added a possibility to display grouped data in the plotdb.C
995 macro (and similar macros). This allows to plot hourly, nightly,
996 weekly, monthly and yearly averages.
997 For more details see the plotall function of the macro
998
999 - general: fixed the error display of the camera display. It showed
1000 wrong results.
1001
1002 - general: fixed a memory leak when reading many MStatusDisplays
1003
1004 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1005 between a spherical and a parabolic mirror
1006
1007 - callisto: We have a new pulse position check which takes the properties
1008 of the extractor automatically into account. So no need to set
1009 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1010 left is done. If possible the lo-gain extraction start and hi-gain
1011 extraction end is changed accordingly. If no proper extraction range
1012 can be set (hi-gain too much to the left) an error is raised.
1013
1014 - callisto: New swapped pixels have been found and corrected
1015
1016 - callisto: Redone the signal extraction this includes:
1017 + Unified the algorithms to extract the pedestal for all pedestal
1018 extractions done
1019 + Unification of hi- and lo-gain into one array
1020 + Unification of hi- and lo-gain extraction for Spline and
1021 Digital Filter (means now exactly the same algorithm is used,
1022 not a copy-and-pasted one)
1023 + Store pedestal subtracted data in a common place
1024 + Improved extraction algorithms. If the algorithms search a
1025 maximum but don't find one they don't return the maximum anymore
1026 + Improved the extraction such that a information for signal
1027 and time which is consistent is returned
1028 + replaced the numerical spline with a (not slower) analytical
1029 solution
1030 + Lowered the saturation limit from 250 to 245 to make sure that
1031 we are far away in all pixels from problems with the clock-noise
1032 + The start of the lo-gain extraction is calculated from the hi-gain
1033 arrival time. In case of saturation an estimation is used.
1034 + the hi-gain window was extended to slice 16. This allows extraction
1035 of very late pulses in single pixels or of huge hadron showers.
1036 + Now uses the lo-gain extraction range for pedestal extraction,
1037 not the hi-gain range in the lo-gain
1038
1039 - callisto: New hi-/lo-gain calibration constants have been produced
1040 for all periods from the statistic of the whole period. They are
1041 now used automatically depending on the periods. The old constants
1042 where deviation in avarega about 2%-3%. The constants are very
1043 stable from period to period (<<1%) except for exchanged channels.
1044 In a few cases the constants used so far were off by 1%-2% (maybe
1045 temperature effects?)
1046
1047 - callisto: To gain obsolete space we do not write the
1048 MPedestalFundamental anymore. Also calibration and bad pixel
1049 treatment is not done for it anymore because it has never been used.
1050
1051 - callisto: Fixed a bug in the seuqence handling which caused the
1052 light condition to be ignored
1053
1054 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1055 basically the same as "Cleaned" but the distribution devided into
1056 the events fullfilling a spark cut or being rejected by it.
1057 This cut can be changed from star.rc (see example inside) by
1058 the "SparkCut" directive
1059
1060 - star: Star displays now the average individual pixel-rate (IPR) versus
1061 time and the average discriminator threshold (DT) of all pixels.
1062
1063 - optim: fixed a problem with the optim-macros which was due to a bug
1064 in the new phrase parsing
1065
1066 - ganymed: To get a nice FalseSource plot (instead of the all-information
1067 debug plot displayed as a standard plot) use the context menu
1068 somewhere between the two upper plots, click on "DrawNicePlot"
1069 and enjoy the result. (It is the same context menu which contains
1070 the other options)
1071 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1072
1073 - ganymed/optim/train: The cut program, trainings- and optimization
1074 macros could run with less files found than expected from the
1075 sequence-files. No the execution is stopped in this case.
1076
1077 - ganymed: now stores the dataset in the output file with all information
1078 contained (as sequence number, sequence path, data path) so that the
1079 used dataset file can be recreated complete from the output
1080
1081 - sponde: now also allows the uasge of random forest
1082
1083 - sponde: added a plot showing the cut efficiency
1084
1085 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1086 errors (eg. effecting the collection area) because the errors of the
1087 two histograms were swapped in the calculation, which makes a difference
1088 in the case the histograms contains weighted events. Aditionally the
1089 totalarea was incorrectly taken into account, which results in too small
1090 errors, which makes a difference at low statistics were the errors
1091 or the collection area dominate.
1092
1093
1094
1095 *** Version 0.10.3 (2006/10/23)
1096
1097 - database: Implemented ObservationMode flag in websites.
1098
1099 - database: For sequences there is now also the stoptime available on the
1100 websites.
1101
1102 - database: Removed ManuallyChanged flag from sequence-info websites,
1103 as it is not needed anymore with the new sequence building algorithm.
1104
1105 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1106 Class for calculation of confidence intervals (upper limits).
1107 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1108 Please read the class instruction of TRolke for more information.
1109
1110 - general: The programs now return 0xfe if the requested resource file
1111 doesn't exist.
1112
1113 - general: Errors comming from root itself are now not output to
1114 stderr anymore but to our default (colored) log-stream.
1115
1116 - general: Changed the interface to TFormula such that now everything
1117 is parsed by TFormula, which should allow to use phrases even
1118 without paranthesis correctly parsed.
1119
1120 - callisto: replaced the AdHoc number of effective integration slices
1121 in the digital filter by an average of the correct number, averaged
1122 over all possible set of weights. This also gives correct numbers
1123 for the lo-gains which were totally wrong before.
1124
1125 - callisto: drastically reduced memory consumption by not storing
1126 all intermediate calibration results in memory anymore (we might
1127 write them into a file in the future)
1128
1129 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1130 debug plot displayed as a standard plot) use the context menu
1131 somewhere between the two upper plots, click on "DrawNicePlot"
1132 and enjoy the result. (It is the same context menu which contains
1133 the "DrawAll" option)
1134 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1135
1136
1137
1138 *** Version 0.10.2 (2006/10/15)
1139
1140 - general: changed the building of the sequence files such, that
1141 the source-/project name in case of wobble-sources is not the
1142 source/project of the first data run anymore but the new generalized
1143 wobble source/project
1144
1145 - general: Added some functions to MAstro to calculate sun and
1146 moon properties
1147
1148 - general: Added two new macros (starvisday.C and starvisyear.C)
1149 which allow to plot the visibility of several stars in one day
1150 or of one star along one year
1151
1152
1153
1154 *** Version 0.10.1 (2006/10/11)
1155
1156 - general: HTML logging output was distorted... fixed.
1157
1158 - general: Changed the writing of the sequencefiles such that only
1159 as many pedestal files as giving at least 1000 pedestal events which
1160 are nearby the first calibration run are used as pedestal runs
1161
1162 - sponde: In the calculation of the collection area(s) and the
1163 distribution for MOnte Carlo and estimated energy the error
1164 calculation was wrong because root didn't take the errors
1165 properly into account... fixed.
1166
1167
1168
1169 *** Version 0.10 (2006/10/10)
1170
1171 - general: all executables now check consistency of the root version
1172 installed with the root version used for compilation. The return
1173 code in this case is 255.
1174
1175 - general: The algorithm to build seqeunces has been redesigned
1176 completly. It is now more flexible in terms of a resource file
1177 resources/sequences.rc which can be used to partly overwrite
1178 the default algorithm and defined the important part of the
1179 algorithm. It also takes correctly into account several ways
1180 of taking wobble-data. Currently the new algorithm doesn't take
1181 the number of pedestal events anymore into account (so a sequence
1182 could have much less than 1000 pedestal events and data runs are
1183 no-more used instead)
1184
1185 - general: a lot of small changes to make the code compatible with
1186 root 5.12/00 and gcc 4.1
1187
1188 - general: Fixed some warnings thrown if more warnings are switched
1189 on in the compiler
1190
1191 - general: Added a function to MMath which returns the Median of
1192 the distribution abs(y[i]-median) but at 68:32 division instead
1193 of 50:50, which is somehow the median counterpart of the rms.
1194
1195 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1196 even if they are compressed with gzip (recommended compression
1197 is with "-1")
1198
1199 - showplot:
1200 + batch mode creation of image files now works with root 5.12/00
1201 + added support for writing bmp (though it never produces
1202 bmp which can be read by programs like xv or gimp)
1203 + added support for xml
1204 + added new option to start the display with a different size, by
1205 --display-width=nnn or --display-height=nnn
1206 + added options to define the canvas size when the display is started
1207 --canvas-width=nnn or --canvas-height=nnn
1208 the option can also be used for batch-mode conversion
1209 + added an option which automatically fits the display size to the
1210 desktop-size: --auto-size
1211
1212 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1213
1214 - merpp: allow the reports to have 1000ms due to a bug in the camera
1215 program.
1216
1217 - callisto: New swapped pixels have been found and corrected. For
1218 details see MRawRunHeader::FixAssignment()
1219
1220 - callisto: Callisto now raises an error if one of the input files could
1221 not be opened.
1222
1223 - callisto: In some rare cases it could happen that in the signal
1224 extraction of the digital filter the extractor returned nonsense
1225 results due a wrong initializion of a variable (this happens in
1226 cases in which the extracted signal is exactly zero or the
1227 digital filter couldn't slide because of a too small extraction
1228 window, which could happen in the lo-gain extraction)
1229
1230 - callisto: The lo-gains have been marked as valid in some cases
1231 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1232 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1233 smaller than the number of slices (fLoGainWindowSize) needed
1234 by the lo-gain extractor
1235
1236 - callisto: Updated absolute calibration constants (muon calibration)
1237
1238 - callisto: fixed a bug which caused the hi-gain saturation not
1239 to be handled properly in the spline (the position of the
1240 saturation was calculated incorrectly)
1241
1242 - callisto: fixed a bug which gave weird results if hi- _and_
1243 lo-gain could not be extracted properly. In some cases hi-
1244 and lo-gain have not been extracted at all and the random result
1245 got calibrated. In other cases the hi-gain was saturating and the
1246 lo-gain has not been extracted. For this a completly arbitraty
1247 scale factor was applied to the result from extracting the
1248 charge of the saturating hi-gain.
1249
1250 - callisto: improves handling of extracted signal if lo- and/or
1251 hi-gain could not be extracted properly. If no appropriate
1252 calibration of either the signal or the arrival time is possible
1253 the pixel is now markes as unsuitable instead of estimated.
1254
1255 - callisto: Fixed a problem in the spline extraction which gave
1256 weird results if the signal was extracted from the first (and
1257 highest) slice (as a workaround extraction from the first
1258 slice has been forbidden)
1259
1260 - callisto: Fixed a bug regarding the use of the QE which doesn't
1261 effect the result because the default is used anyhow.
1262 (The bug was there since 14/07/2005)
1263
1264 - callisto: Changed the default for fgLoGainStartShift to -2.4
1265
1266 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1267 factors to be always 10 for all pixels as soon as the first
1268 calibration update has happend.
1269
1270 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1271 was off by more than one slice (which gives wrong values for
1272 pixels which have saturated the hi-gain) This was a problem
1273 mainly for timing studies, not so much for the automatic standard
1274 analysis. Also the values for the Spline have been changed slightly:
1275 + Digital Filter from 1.70 to 0.95
1276 + Spline from 1.39 to 1.30
1277 The numbers were sorted out by an extensive test in the
1278 test-database.
1279
1280 - callisto: Removed the tab showing the average calibrated arrival
1281 time. It never gave useful information.
1282
1283 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1284 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1285 and both were extracted because the hi-gain was above the
1286 LoGainSwitch.
1287
1288 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1289 lo-gain pulse position (after application of LoGainOffset, which
1290 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1291 have saturated and both were extracted because the hi-gain was above
1292 the LoGainSwitch.
1293
1294 - callisto: After extensive tests a new threshold level for determination
1295 of the pulse position has been found at 50phe. This is due to the
1296 fact that for lower pulses the arrival time changes its average
1297 behaviour dramatically. It tends to the average of the extraction
1298 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1299
1300 - callisto: Added two more plots to the calibration part. The average
1301 extracted signal and the average extracted arrival time as
1302 extracted by the signal extractor (This can help debugging problems
1303 because it doesn't involve a fit)
1304
1305 - star: changed the fit for the effective on time such that initial
1306 values are calculated automatically now instead of using build
1307 in values. This makes the fit more indepedant of the underlaying
1308 rates. With a test of ~350 sequences in the test database it could
1309 be shown that the new fit gives the same result +/-1sek.
1310 The highest deviation was +5s the lowest -10s. You can now control
1311 the bahaviour with two resource values:
1312 MHEffectiveOnTime.FistBin: 3
1313 MHEffectiveOnTime.NumEvents: 12000
1314 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1315 from the resulting gamma candidates
1316
1317 - star: The Center histogram in MHHillas is now by default displayed
1318 with the colz draw-option
1319
1320 - ganymed: now produces valid error codes if failed
1321
1322 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1323 with the option "hadronness" instead of "area" or "both" if
1324 you want to use both cuts. The hadronness cut includes a fixed
1325 cut in hadronness (index 8) and a fixed cut in size (index 9).
1326
1327 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1328 the M3Long of the anti source to be not properly evaluated
1329 (actually is was evaluated as a unique random number) in case
1330 of optimization with anti-theta cut switched on. This might have
1331 lead to improper, but not necessarily wrong, optimization results.
1332
1333 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1334 how to use random forest
1335
1336 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1337 ganymed_onoff.rc. Seems to be unintentional that they were different.
1338
1339 - sponde: Since the introduction of the possibility to define a
1340 normalization energy instead of using the integral the default
1341 was not using the integral anymore but a normalization energy of
1342 1GeV. It is now the integral again.
1343
1344 - sponde: Fixed a problem in the weighting which did not allow
1345 a MC slope of -1.
1346
1347
1348
1349 *** Version 0.9.6 (2006/05/24)
1350
1351 - general: changed the binning of the azimuthal profile of the camera
1352 such that it is aligned with the 60deg boundaries.
1353
1354 - merpp: better handling of problems with the TH, TD part of the
1355 CC-REPORT for files older than 200507190 and 200412210
1356 respectively
1357
1358 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1359
1360 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1361
1362 - callisto: if an arrival time is extracted outside the fadc range is
1363 was set to the boundary before. Now a random number is assigned
1364 instead to avoid unfortunate coincidences of arrival times just
1365 by this arbitrary value.
1366
1367 - callisto: added a new option to callisto.rc which allows
1368 to set the maximum arrival time difference allowed for the
1369 badpixel algorithm to determin whether a pixels belongs to a shower:
1370 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1371
1372 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1373 to 0.9 as suggested by Stefan due to a recent study on the fraction
1374 of pixels surviving the image cleaning
1375
1376 - callisto: switched off error in case of "pulse is too much to the left"
1377
1378 - callisto: The extraction window is not adapted anymore. This means that
1379 the pulse is extracted from the full range. The draw-back is that the
1380 background (pedestal) will become slightly higher. Switching on/off
1381 the PulsePosCheck in the callisto.rc only effects filling the
1382 histograms.
1383 WARNING: If the pulse is too much to the left data is calibrated!
1384 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1385 in the database to make sure that your data is valid!
1386
1387 - star: Show also the number of stars correlated correctly by the
1388 starguider
1389
1390 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1391 than one off-source region in wobble-mode. To use it add the following to
1392 your ganymed_wobble.rc:
1393 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1394 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1395 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1396 + Cut1.ThetaCut: None
1397 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1398
1399 - ganymed: in the case the latest report is older than a default (currently
1400 one minute) and the current report will be skip the starguider
1401 correction and calibration will be reset. The maximum age can be
1402 setup from ganymed.rc by (minutes):
1403 MPointingDevCalc.MaxAge: 1.5
1404
1405 - ganymed: A first implementation showing all size-bins for the theta-sq
1406 resp. alpha-plots in a single tab automatically
1407
1408
1409
1410 *** Version 0.9.5.1 (2006/05/05)
1411
1412 - general: Added a new option "zdiff" to the Makefile which runs
1413 "cvs diff" as "make diff" would do, but with compression
1414
1415 - general: accelerated MTFillMatrix (used for eample in all training
1416 and optimization macros) by skipping some obsolete calles in the
1417 eventloop the first and second loop could be accelerated by ~20%
1418
1419 - general: Added a missing feature in the MFilterList class which
1420 prevented MFEnergySlope from working correctly in trainenergy.C
1421
1422 - general: Accelerated the random forest training and usage a bit
1423
1424 - merpp: Adapted to new raw data file format version 6
1425
1426 - merpp: fixed a problem with reading the starguider reports
1427 after 6.3.2006
1428
1429 - callisto: At some times six pixels had to be exchanged manually in the
1430 data. If the pixels to be swaped are both not found, an error was raised
1431 and calibration was stopped. Now it is assumed they are intentially not
1432 mapped and the Error has been changed to a Warning.
1433
1434 - star: Added new image cleaning based on the arrival time of the shower.
1435 The new cleaning can be accessed using the parameter "Time" instead of
1436 the the old one (like "Absolute) in the star.rc-file.
1437 Recommended parameters:
1438 + MImgCleanStd.CleanLevel1: 8.2
1439 + MImgCleanStd.CleanLevel2: 5
1440 + MImgCleanStd.CleanRings: 2
1441 + MImgCleanStd.KeepSinglePixels: No
1442
1443 - star: Simplified the calculation of the effective on time. By letting
1444 the fit start in the third bin the result should become more stable.
1445 The fit quality is now ignored for the theta-plot which is not used
1446 in the analysis later. Still better pre-cut which, for example,
1447 remove events triggered by car-light (rate changing on a short
1448 time-scale) are missing.
1449
1450 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1451 for optimization (kWeakSource) which is suggested by the Berlin
1452 people for weak sources.
1453
1454 - macros: plotdb.C:
1455 + if no dataset and no time-interval is given only sequences with
1456 an effective on-time above five minutes are plotted anymore
1457 + added a new tab "RelTime" displaying the relative on-time
1458 (effective on-time divided by the observation time)
1459
1460 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1461 the optimization became a lot faster
1462
1463 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1464 To display them just delete the pads displayed on top.
1465
1466 - ganymed: fixed a bug which could cause strange behaviour in wobble
1467 mode if no starguider information was available due to an incorrect
1468 initialization of the starguider calibration
1469
1470 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1471 be changed from within the plot. It can also be setup from the
1472 resource file using:
1473 + MHDisp.fScaleMin: 0.325
1474 + MHDisp.fScaleMax: 0.475
1475
1476 - ganymed, showplot: Fixed a problem with the fit to the off-data
1477 (HistOff) which could cause a time lag or an inifinite loop.
1478 The bug did not effect the results at all.
1479
1480 - sponde: Added a new tab showing the effective collection area after
1481 trigger (including the software trigger)
1482
1483 - sponde: MMcSpectrumWeight has a new option which allows to define
1484 the scaling factor not by the integral of the events but at
1485 a defined energy:
1486 e.g. MMcSpectrumWeight.NormEnergy: 200
1487
1488 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1489 eventloops the loop could be accelerated by ~20%
1490
1491
1492
1493 *** Version 0.9.5 (2006/03/13)
1494
1495 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1496 and added the standard Disp-parametrization
1497
1498 - macros: added a new macro datacenter/macros/plotstat.C allowing
1499 to plot statistics about the data processing
1500
1501 - macros: added a new macro to plot the muon correction coefficients
1502 versus period (macros/plot/mucal.C)
1503
1504 - showplot: path inflation for ganymed files was broken
1505
1506 - callisto: Fixed an important bug. When the number of saturating pixels
1507 were calculated the bad pixel information already available from the
1508 calibration was ignored. This yields wrong values in case pixels
1509 are broken and saturate all the time or randomly.
1510
1511 - callisto: Updated Muon calibration constants. Spline data now also uses
1512 different values for different periods
1513
1514 - star: The time-evolution shown in the effective on-time plot now displays
1515 the axis range (if there are no holes it should be similar to the
1516 effective on-time)
1517
1518 - star: Added two new image parameters:
1519 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1520 the three pixels next to the center of gravity and the size
1521 + MNewImagePar.fConcCore: The ratio of the signals of all
1522 pixels inside or touching the ellipse and the size
1523
1524 - ganymed: now stops in requested source isn't found in catalog file
1525
1526 - ganymed: Many improvements to the phi-plot in wobble mode:
1527 + with a template the ideal background is displayed
1528 + a possible camera inhomogeneity is taken into account
1529 + the anti theta cut is better supported
1530 + the phi cut is automatically calculated from the theta cut
1531 See the examples in ganymed_wobble.rc for more details.
1532
1533 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1534 times the bin-width instead of the absolute energy
1535
1536 - ganymed: New cuts for on/off and wobble mode
1537
1538 - ganymed: The smearing of the False Source plot has been increased
1539 to 0.06
1540
1541 - ganymed: The starguider calibration can now be changed from the
1542 resource file.
1543 See the examples in ganymed*.rc for more details.
1544
1545 - ganymed: added a new option for on-/off-observations
1546 MJCut.RandomSourcePosition
1547 If switched on the distribution of observation time of the source
1548 position in the camera is calculated from the on-data and randomly
1549 applied with this distrbution to the off-data.
1550
1551 - ganymed: by skipping some obsolete calles in the eventloop the
1552 first and second loop could be accelerated by ~20%
1553
1554 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1555 position in the off-data randomly according to its distribution in the
1556 on-data.
1557
1558
1559
1560 *** Version 0.9.4.3 (2006/02/13)
1561
1562 - general: Fixed a bug in most of the programs which prevented the
1563 compile date in the startup message to be displayed
1564
1565 - general: Simplified program calls. The following abbreviations
1566 are now possible:
1567 showlog callisto 55599
1568 showplot signal 55599
1569 star 55599
1570 callisto 55999
1571 ganymed 2
1572 In this cases the corrsponding root-, log-, sequence- or dataset-
1573 filename is automatically compiled using the default datacenter
1574 paths ("/magic/*")
1575
1576 - general: Fixed a long outstanding bug which made axis tick marks
1577 disappear if MDataFormula was used (eg. abs(x))
1578
1579 - general: Updated MMath with new functions to calculate the results of
1580 a exponential, logarithmic and powerlaw fits analytically.
1581
1582 - general: Updated some macros with comments:
1583 + macros/optim/optimdisp.C
1584 + macros/optim/optimenergy.C
1585 + macros/optim/optimwobble.C:
1586
1587 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1588 files) now allows adding a pre-cut like in the optimization. E.g. this
1589 is useful to perform g/h-separation cuts before training the random
1590 forest.
1591
1592 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1593 correctly assigned in the raw data assignement table. A fix to correct
1594 the assignment tabel have been implemented.
1595
1596 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1597 by 90, 180 and 270 deg.
1598
1599 - general: the macro plotdb.C now allows to highlight sequences belonging
1600 to a datset. For more details see the descritions in the macro.
1601
1602 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1603 of the display, it gave wrong results espacially for big sizes.
1604 Now the embedded canvas should always have a ratio width/height=3/2.
1605 The "Size" options have been updated with values fitting the 3/2
1606 size ratio.
1607
1608 - RanForest:
1609 + Updated the random forest classes to support also the
1610 regression method implemented by Thomas H.
1611 + added new tutorial macro how to train the random forest
1612 for energy estimation (macros/optim/rfenergyest.C)
1613 + new classes to train the random forest (still in development)
1614 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1615 + new tutorial macros for random forest training in macros/train
1616 trainenergy.C, traindisp.C, trainseparation.C
1617
1618 - mars: now allows to setup a cut in the resource file mars.rc to choose
1619 the events to be displayed, eg:
1620 Cut.Condition: {0} && {1}
1621 Cut.0: MHillas.fSize>100
1622 Cut.1: MHillas.fSize<900
1623
1624 - merpp: Made aware of the new .rep format 200510250. This includes
1625 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1626 the discriminator thresholds (MCameraTD) and the disciminator
1627 delays (MCameraTD). All of them come with the CC report and are therefor
1628 written to the CC tree.
1629
1630 - callisto: fixed a bug in the calculation of the arrival times in
1631 the Digital Filter. They were all shifted by the same amount
1632 fHiGainFirst. This caused an offset in the order of the position of
1633 the left border of the extraction window in the times calculated
1634 from high-gain and from low-gain. The bug effected only the absolute
1635 arrival times. The bug was there since 30.1.2005.
1636
1637 - callisto: Changed the ExtractionWindow for the pulse position check
1638 such that the camera inhomogeneity becomes as less as possible and
1639 comparable to the pulso position check switched off. More details
1640 on the study will be given at our result web-page.
1641
1642 - ganymed: ganymed.rc, ganymed_onoff.rc:
1643 changed to new cuts trained with 1ES1218 and Crab-data
1644 for maximum sigma*log10(excess)
1645
1646 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1647 a new option was implemented to estimate Disp (CalcDisp)
1648
1649 - ganymed: Implemented two new options which allow
1650 to overwrite the default path to search for the sequence files
1651 --ins=/magic/sequences
1652 and where to search for the image data
1653 --ind=/magic/data/star
1654
1655 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1656 dx/dy from the resource file by
1657 MSrcPosCorrect.Dx
1658 MSrcPosCorrect.Dy
1659
1660 - ganymed: fixed reading the source catalog. Only as many chars
1661 as the requested source name had were compared (If a source
1662 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1663 were requested it could happen that the coordinates of
1664 "1ES1218" were read) The source coordinates are now printed
1665 in addition to its name to the logging output.
1666
1667 - ganymed: changed the background fit in the case of a ThetaSq function
1668 from a polynomial to a exponential, this should give a big improvement
1669 for on-only analysis'
1670
1671 - ganymed/sponde: Calculation of the error of single size-/energy-
1672 bins now uses Li/Ma (5) instead of LiMa (17)
1673
1674 - sponde: Added a plot E^2*dN/dE
1675
1676 - sponde: The energy estimator plot should now show values like
1677 they are commonly used.
1678
1679 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1680 (a powerlaw with cutoff didn't work before)
1681
1682
1683
1684 *** Version 0.9.4.2 (2005/10/01)
1685
1686 - general: added new tutorial macro macros/tutorials/threshold.C:
1687 how to calculate the threshold
1688
1689 - general: added a new game. Start it from the interpreter with
1690 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1691 and MagicReversi)
1692
1693 - general: neighbor pixels in MGeoms are now sorted clockwise
1694
1695 - merpp: made aware of new format 20050829-0
1696
1697 - callisto: New scale factors from muon analysis, stored in new
1698 resource file resources/calibration.rc
1699
1700 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1701 the eventloop if something went wrong. This is necessary for the
1702 automatic processing
1703
1704 - callisto: Implemented a new treatment for the time information
1705 developed by S.Ruegamer, this should give much better response than
1706 the old very primitive algorithm. This is especially important
1707 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1708 treatment was buggy! As neighbor pixels to interpolate the
1709 arrival times always the pixels 0 to 5 were taken)
1710
1711 - callisto: In addition to the new treatment of arrival times the
1712 decision of the treatment whether a pixel contains shower
1713 information or not is used to improve the signal interpolation
1714 further. Previously interpolated pixels showed a non-zero signal
1715 do the peak searching signal extractors. Having a signal pixel
1716 beside raised the signal above the cleaning level. Thus the
1717 pixel survived cleaning to often but with a too low mean signal.
1718 By replacing empty pixels with a gaus (mean and rms from the
1719 corresponding Area entries in MPedPhotCam) this effect can
1720 be supressed.
1721
1722 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1723 got lost when the events were stored by the calibration... fixed.
1724 (This was no problem for normal image cleaning because the pixel
1725 content was artificially set to 0 not surviving standard cleaning
1726 algorithm)
1727
1728 - callisto: Fixed a bug which caused the random and peak-search pedestal
1729 extracted with an extractor to be exchanged for the first (roughly)
1730 500 events (*Extractor and *ExtractorRndm).
1731 (They were simply exchanged in callisto.cc) This bug might have been
1732 introduced in Mars 0.9.4 when the order of calculation of the two
1733 types of pedestal in callisto got exchanged. The bug only effects
1734 the first seconds of data of each sequence.
1735
1736 - star: Taking the arrival time of Muons into account the calculation
1737 of the parameters could be made independant of the noise
1738 (pedestal rms). The dependance was due to the bias of the peak search
1739 extractor. Now only a ZA dependamcy is left which is not yet fully
1740 understood.
1741
1742 - ganymed: The sequences were still not sorted correctly in any case,
1743 because they were sorted by the full qualified path name. Now they
1744 are sorted by their sequence number.
1745
1746 - ganymed: new values for the spark-event-cut
1747
1748 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1749
1750
1751
1752 *** Version 0.9.4.1 (2005/08/18)
1753
1754 - callisto: fixed some problems with the calibration in case of
1755 inteleaved events. Therefor the final and some intermediate
1756 fits are skipped which would take place on partly filled #
1757 histograms and gave wrong results or failed completely.
1758
1759 - callisto: If the intermediate finalization of the histograms
1760 calculating the mean charge of the calibration signal fails
1761 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1762
1763 - ganymed: Fixed some bugs which caused problems in On-only mode.
1764 Still the false source plot doesn't give reasonable results.
1765
1766
1767
1768 *** Version 0.9.4 (2005/08/05)
1769
1770 - general: Fixed the ZA binning. It did not correctly fit the
1771 MC binning
1772
1773 - general: Added a class to correct for the missfocussing in
1774 April (MSrcPosCorrect)
1775
1776 - general: Random Forest energy estimator should now work properly
1777
1778 - general: MHCamera now displays the profiles in deg instead of mm
1779
1780 - general: MH::SetPalette offers a lot of new palettes
1781
1782 - general: MHillas - the case of CorrXY==0 is now handled properly
1783
1784 - general: implemented the possibility to change the line and
1785 marker style of a sky-grid drawn by MAstroCatalog
1786
1787 - general: Runs in sequences and datasets are now automatically
1788 ordered (it is assumed that the order of their filenames correctly
1789 represents the order of observations) to ensure correct reading
1790 of the subsystem data
1791
1792 - general: Runs cannot be added to a sequence twice anymore. Also
1793 Sequences cannot be added twice anymore to a dataset.
1794
1795 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1796 It gave wrong results by 1./2pi
1797
1798 - showplot: got a new option to start a root interpreter, too
1799
1800 - mars: now displays a rough estimate of Disp and the third moment
1801
1802 - mars: now displays the event time MTime if available
1803
1804 - mars: show muon parameters graphically
1805
1806 - mars: now the file to open can be given as commandline
1807 argument
1808
1809 - merpp: Added support for new arehucas version >= 200507190
1810 implementing values for three temperature sensors in the
1811 counting house (MCameraAUX) and the name of the HV settings file
1812 (MCameraHV).
1813
1814 - merrp: Also fixed some problems with wrong versions numbers stated
1815 by arehucas and implemented some fixed for old versions (<200407070)
1816
1817 - callisto: MCalibrationHiLoCam can now be printed from its context
1818 menu, eg in the TBrowser
1819
1820 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1821 - 1.39 (MExtractTimeAndChargeSpline)
1822 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1823 This is important mainly for timing studies.
1824
1825 - callisto: Changed limits in MHCalibrationChargeCalc from
1826 - -100.125 to -98 (fgChargeHiGainFirst)
1827 - 1899.875 to 1902. (fgChargeHiGainLast)
1828 - -100.25 to -99 (fgChargeLoGainFirst)
1829 - 899.75 to 901. (fgChargeLoGainLast)
1830 Introduced new limits:
1831 - fgNumLoGainBlackoutLimit: 0.05
1832 - fgLoGainBlackoutLimit: 3.5
1833 - fgLoGainPickupLimit: 3.5
1834
1835 - callisto: The handling of automatic weights for the digital filter
1836 has been improved. There are now new calibration weights special
1837 for Monte Carlo calibrations.
1838
1839 - callisto: Updated Muon scale with latest results (1% difference
1840 for most data, 5% for Mar/Apr'05)
1841
1842 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1843 was saturated and the blackout-events in the low-gain exceed the
1844 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1845 This excludes those pixels which have a saturating high-gain
1846 channel, but the low-gain switch does not switch often enough
1847 to make the distribution reliable.
1848
1849 - callisto: fix a bug counting the number of saturated events. Up to now,
1850 the number of saturated slices was counted (which is one for a not too
1851 high number), but for some (pathological) pixels, many more slices
1852 saturated and produced wrong limits.
1853
1854 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1855 + MCalibrationRelTimeCam.CheckFitResults: Yes
1856 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1857 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1858 + MCalibrationRelTimeCam.CheckOscillations: Yes
1859
1860 - callisto: introduce max. number of events for intercalibration,
1861 the rest gets skipped. Default: 4096
1862 The calibration causes too many un-reliable pixels if more
1863 than about 5000 events are treated (@500 Hz) because of the
1864 mode hopping of the VCSels. However, in the past, some
1865 calibration runs have been taken (erroneously) with more
1866 than 5000 events, especially the intensity scans where
1867 a good precision is needed.
1868
1869 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1870 photo-electrons for the spline extractor by 1-2% (correctly).
1871
1872 - callisto: The intercalibration is now done using a full f-factor
1873 method instead of a simple update. This makes things slower but
1874 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1875 changes.
1876
1877 - callisto: MPedestalY3 now uses the same extraction range as the data
1878 as calculated by MPedestalY2
1879
1880 - callisto: A check of the fraction of allowed unsuitable (10%) and
1881 unreliable (30%) pixels has been addded when the conversion is
1882 calculated from interleaved events
1883
1884 - star: fixed a bug which caused MEffectiveOnTime containers not to
1885 be written. In the worst case they were skipped almost all, in the
1886 best case they were all ok. It depends on how often the new value
1887 was assigned just with an event which was skipped later by another
1888 task
1889
1890 - star: new histograms MHPointing and MHRate
1891
1892 - star: New tab (Currents) displaying the time evolution of the mean
1893 DC currents
1894
1895 - star: New tab (MeanRms) displaying the time volution of the mean
1896 Pedestal Rms
1897
1898 - star: Output now contains MReportStarguider
1899
1900 - star: Improved muon analysis. Due to the absense of a constant
1901 for the gaus fit for arc width and the fact that the arcwidth
1902 plot was a histogram instead of a profile the resulting psf
1903 became pedestal rms dependant
1904
1905 - ganymed: added new plot (MHPhi) for wobble mode as described in
1906 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1907
1908 - ganymed: corrects now (correctly?) for the misspointing in
1909 May/April 05
1910
1911 - ganymed: Two new default templates for ganymed.rc are avilable:
1912 ganymed_onoff.rc and ganymed_wobble.rc
1913
1914 - ganymed: The first version of MFMagicCuts has been released
1915
1916 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1917
1918 - ganymed, sponde: There are two new options to determin the number
1919 of bins for the signal region (NumBinsSignal) and the number of
1920 total bins (NumBinsTotal) in the MHThetaSq histogram
1921
1922 - ganymed: optimized palettes for MHDisp
1923
1924 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1925 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1926 sqrt(2) to large
1927
1928 - ganymed: The false source plot (MHDisp) is now based on Disp
1929 and a background model determined in the first loop is
1930 subtracted
1931
1932 - ganymed: MFMagicCuts are now available in the cvs. The correct
1933 solution for the disp ambiguity problem is now calculated using
1934 the third moment. The third moment cut therefor is skipped.
1935
1936 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1937 already determined by the third moment along the major axis and
1938 so its actual sign is aligned along the major axis of the shower.
1939
1940 - ganymed: If starguider data is available it is taken into account
1941 when calculating the source position. This is especially important
1942 for wobble data at high zenith angles and culmination data.
1943
1944 - ganymed: If available the starguider data is taken into account as
1945 good as it is possible without a starguider calibration. To switch
1946 it off add
1947 MPointingDevCalc.MaxAbsDev: -1
1948 to your ganymed.rc
1949
1950 - sponde: the zenith angle distribution is now weighted instead of
1951 choosen by default. This gurantees higher statistics in the highest
1952 and lowest energy bins. To switch this behaviour off use...
1953
1954 - sponde: now automatically displays the energy threshold
1955
1956
1957
1958 *** Version 0.9.3 (2005/06/03)
1959
1960 - general: MMcEvt now derived from MMcEvtBasic which should
1961 have no influence on compatibility with older camera files
1962
1963 - general: Implemented a new option to MReadReports which allows
1964 to force reading of the first event of some trees (eg. Drive-tree)
1965 before any other tree.
1966
1967 - general: Made a fix to MPointingPosCalc which assumes that the
1968 run-type is real-data if Process is called before ReInit, such
1969 that also the very first Drive-events in a run are treated
1970 correctly.
1971
1972 - shoplot now displays the filename in the title bar of the window
1973
1974 - merpp: new options: --auto-time-start --auto-time-stop which
1975 allow to cut updating with slow-control at the start- or
1976 (previousle --auto-time only allowed: and) stop-time of
1977 the run stored in the runheader.
1978
1979 - callisto: changed default of fgFallTimeHiGain in
1980 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
1981 already set as default in callisto_Dec04Jan05.rc
1982
1983 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
1984 now changes the filename for new weights automatically for
1985 cosmics, MC and for different calibration colors.
1986
1987 - callisto: a problem with the order of some code cause the
1988 name of the weights file in MPedestalY2 to be ignored.
1989 Wrongly the calibration_UV weights were used instead
1990 of the cosmics weights set in callisto.rc.
1991
1992 - callisto: should allow ct1 pulser data when the color is
1993 explicitly set also for pretty new runs
1994
1995 - callisto: a new option (MCalibrateData.ScaleFactor) allows
1996 to introduce an additional scale factor (should be around 1)
1997 to adapt for slight deviations in different extractors from
1998 the MC calibration. For MC calibrations the scale factor
1999 is fixed to 1
2000
2001 - callisto: MFCosmics should handle very high signals a bit
2002 more accurate now
2003
2004 - callisto: when calculating the mean pedestal rms for different
2005 pixel sizes or sectors also kUnsuitableEvt is now taken into
2006 account - not only kUnsuitableRun
2007
2008 - callisto: '-raw' option is now the default
2009
2010 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2011 This has the advantage that mean values in the calibration (eg
2012 arrival times) are calculated more accuratly.
2013
2014 - callisto: In the resource file callisto_Dec04Jan05.rc
2015 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2016
2017 - callisto: new Hi-/Lo-Gain intercalibration constants
2018 hilocalib_sp1.root and hilocalib_sp1_mc.root
2019
2020 - callisto: changed default for MJPedestalY2.MaxEvents
2021 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2022
2023 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2024 has changed from 9.0 to 6.0. This is necessary to exclude two very
2025 ringing pixels in September which - when kept - destroy the image
2026 cleaning around them (Markus G.)
2027
2028 - callisto: (!) The Muon analysis of all data taken so far has
2029 suggested that different extractors give slightly different
2030 absolute results after calibration, due to there different
2031 handling of the calibration- and cosmics pulse shape. Although
2032 the over all calibration seems to be a bit to pesimistic (or
2033 the MC seems to be a little bit - 3-5% - too much attenuated).
2034 There for correction factors have been introduced which correct
2035 the calibration constants by
2036 0.956937799 for Digital Filter (callisto.rc)
2037 and
2038 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2039 calibration. The main advantage is, that both data types can
2040 be easily analysed together and compared to the same MC sample.
2041 The factors are choosen such, that the reference is now a
2042 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2043
2044 - star: fixed a bug which caused the first bin of the histograms
2045 vs time to disapear in PostProcess. This gave wrong results
2046 on the screen. The output and all following programs not
2047 directly accessing the histograms haven't been affected
2048
2049 - star, ganymed: Made sure that always the first Drive-tree event
2050 is read and Processed before the first data event was read.
2051
2052 - ganymed: implemented the possibility to replace the standard
2053 false source plot with a different one. For example: If
2054 you want to use a Disp based FS plot use the resource:
2055 NameHistFS: MHDisp
2056 For details about the requirements of these plots look
2057 at the corresponding classes
2058
2059 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2060 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2061 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2062 case MAlphaFitter is setup correctly. For On-Only optimization
2063 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2064 RunOn() instead of Run(). For energy estimation MJOptimize
2065 has been replaced by MJOptimizeEnergy
2066
2067 - sponde: The input MC spectrum can now be weighted to fake a
2068 different spectrum. This is done via MMcSpectrumWeight. For
2069 more details see the class description and sponde.rc
2070
2071 - sponde: The paremeter comparsion plots are not scaled by
2072 their entries anymore. Instead the MC plot is scaled by using
2073 the result spectrum of the analysis. If the input MC spectrum
2074 and the result spectrum has different slopes the absolut
2075 normalization is normally wrong.
2076
2077
2078
2079 *** Version 0.9.2 (2005/05/20)
2080
2081 - general: Changed the default paths for calibrated data and image
2082 files. (The implemented access to these files doesn't yet exist)
2083
2084 - general: support for MRunIter has been removed from the job classes
2085 (use the setter functions of MSeqeunce instead)
2086
2087 - general: ProcessFile has been renamed to Process in all job classes,
2088 because ProcessFile is missleading
2089
2090 - general: The storage of the palette in MHCamera is now possible
2091
2092 - general: new bits describing unsuitable and unreliable pixels have
2093 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2094 kDeadPedestalRms, kFluctuatingArrivalTimes
2095
2096 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2097 versions newer than V200404070
2098
2099 - general: support for cc file versions newer than V200504130. Added
2100 support for active loads (MCameraActiveLoad) and central pixel
2101 (MCameraCentralPixel)
2102
2103 - general: added new histograms for image parameters versus size
2104 (MHVsSize)
2105
2106 - general: The eventloop now automatically calls PrintStatistics
2107
2108 - Status Display: Improved support for printing:
2109 + A default can now be set in .rootrc (for more details see
2110 MStatusDisplay::PrintPS)
2111 + A print dialog is opened so that printer and command line
2112 can be canged
2113
2114 - showlog: improved such that it handles different verbosity levels
2115 more accurate now. This mean you can suppress output when
2116 using showlog.
2117
2118 - showplot: improved
2119 + The new graphics formats have been implemented
2120 (pdf, svg, png, jpg and xpm)
2121 + Implemented an interface for printing. Because you can change
2122 the printing command from the command line you can use all
2123 the nice postscript tool. To print a booklet for example call:
2124 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2125 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2126 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2127
2128 - callisto: fixed a bug in the recognition of the calibration bit
2129 pattern. Concerns only intensity calibration. (The strength of the
2130 intensity has been updated in some cases)
2131
2132 - callisto: add a filter against PIN Diode events when running over
2133 calibration runs since some of the recent calibration runs have
2134 been taken with Pin Diode.
2135
2136 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2137 39943, 44833 in the calibration (MCalibColorSet)
2138
2139 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2140 been set to 1e-18 in callisto_Dec04_Jan05.rc
2141
2142 - callisto: in callisto_Dec04Jan05.rc: set value for
2143 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2144 statistics for the calculation of the mean pulse time
2145 of the cosmisc
2146
2147 - callisto: the charge limit in the calibration has been raised
2148 from 2.5 to 4.5
2149
2150 - callisto: new setup read from callisto.rc
2151 + MCalibCalcFromPast.fNumEventsDump
2152 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2153 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2154
2155 - callisto: MExtractTimeAndChargeSpline extractor:
2156 + The integration ranges were shifted by 0.2 FADC slices to the right.
2157 + unreliable handling of floating point values caused different
2158 results on different platform or with different compiler options:
2159 The new algorithm is numerically exact and more accurate because
2160 it doesn't calculate the integration position by multiple times
2161 adding the step-size (which results in numerical uncertanties
2162 exspecially if multiplied with large numbers)
2163 + A lot of fixes have been introduced which effects integrating the
2164 spline at the edges of the valid range. In this case any memory
2165 was randomly accessed. This behaviour can be tested replacing
2166 all MArrayF by TArrayF which perform a range check (but of course
2167 they are a lot slower)
2168 ! No result obtained with the Spline before can be trusted! Due to
2169 random memory access it might by completely random!
2170
2171 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2172 + extraction range in the high gain to 4.
2173 + weights file to cosmics_weights46.dat
2174
2175 - callisto:
2176 + introduce the check for fluctuating arrival times.
2177 + set charge limit to from 2.5 to 4.5
2178 + introduce asymmetric exclusion due to "deviating number of phes":
2179 Default: -9.0 +4.5
2180 + make deviating number of phes unsuitable (see David's findings).
2181
2182 - callisto: fixed the display of unsuitable pixels. The old change
2183 to a real profile in MHCamera broke it.
2184
2185 - callisto: The cosmics filter is used in MJCalibration now
2186 independant of the pulser color (formaly it was used only for
2187 CT1-pulser data). The threshold of number of max empty pixels
2188 has been raised from 2% to 5% in MJCalibration. The maximum
2189 fraction of rejected event is 50% otherwise the calibration has
2190 failed. The filter now ignores unsuitable pixels.
2191 Setup the filter from callisto.rc using "ContCosmics"
2192 (see MFCosmics::ReadEnv)
2193
2194 - callisto: changed default for fgOffsetFromLogain back
2195 from -2.8 to -1.8 in digital filter.
2196
2197 - callisto: for the common extractors
2198 + MExtractFixedWindow
2199 * MExtractTimeAndChargeSlidingWindow
2200 * MExtractTimeAndChargeSpline
2201 * MExtractTimeAndChargeDigitalFilter
2202 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2203 and fResolutionPerPheLoGain
2204
2205 - callisto: Updated the hi-/lo-gain intercalibration constants
2206 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2207 hilocalib_df6.root
2208
2209 - callisto: The default lo-gain extraction window for the
2210 MExtractTimeAndChargeSlidingWindow extractor has been increased
2211 from 6 to 8 to take the stretch of the pusle into account
2212
2213 - callisto (!!!): fixed an important bug in the setting of the
2214 incoming pedestal pointer to the signal extractor extracting
2215 pedestals. This bug caused the pedestals not to be subtracted
2216 correctly in the calibration afterwards. The effect was about 10%
2217 too high conversion factors for the digital filter and the spline
2218 and more than 40% for the sliding window.
2219 The bug existed since end of February! (Markus G.)
2220
2221 - star: added muon support to star. A new tab "MHMuonPar" is
2222 displayed. The lower right plot is an estimate of the point spread
2223 function. A reference value is displayed. To get the real PSF
2224 you must compare with MC. The setup for the muon analysis
2225 is done in star.rc. More informations can be found in
2226 MHSingleMuon and MHCalibParCalc
2227
2228 - star: The weather data is now displayed in star
2229
2230 - star: MEventRateCalc handles the calculation of the event rate more
2231 accurate now in case of the start of a new run inside a sequence
2232
2233 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2234 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2235 changed only minimally
2236
2237 - ganymed: (MJCut and MJOptimize) now displayes the number of
2238 excess events versus size. The energy estimation is done in
2239 MJSpectrum (sponde)
2240
2241 - ganymed: got support for using other variables than Alpha, eg. Theta.
2242 Therefor you need a class deriving from MHAlpha which supports
2243 this variable (one is already existing: MHTheta, which is now the
2244 default in ganymed). It is setup through ganymed.rc
2245
2246 - added a full featured spectrum program (sponde) which reads
2247 ganymed output and monte carlos and compiles a spectrum
2248
2249
2250
2251 *** Version 0.9.1 (2005/04/14)
2252
2253 - Fix bug on the arrival time reconstruction when using Digital
2254 Filter (in some marginal cases (10%) times were reconstructed shifted
2255 by 0.2 slices)
2256
2257 - all executables now return 2 where in previous versions -1 has
2258 been returned (gave problems with shell-scripts)
2259
2260 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2261 also done with a intercalibration input file
2262
2263 - a bug in the time fine adjustment of the digital filter has been fixed
2264
2265 - a lot of small fixes to calling TPad::Divide with a margin==0
2266
2267 - MStatusDisplay now shows the memory usage
2268
2269 - added a memory leak statistic after the eventloop
2270
2271 - MHadronness replaced by MParameterD
2272
2273 - MEnergyEst replaced by MParameterD
2274
2275 - wobble mode can now be switched on from the data-set
2276
2277 - switched on bad pixel detection for a pedestal level
2278 which is more than 5 times the variance
2279
2280 - Fixed default paths to be correct for the new data center
2281
2282 - Fixed handling of drive data. The pointing position in now
2283 copied to MPointingPos inside star for real and MC events
2284
2285 - made sure, that the sequences in a dataset are sorted by
2286 their number to ensure the correct synchronization
2287
2288 - added all resource files necessary to handle spline extraction
2289 of signal for the late 2004 and the early 2005 data
2290
2291 - update the reference lines for the december data
2292
2293 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2294 This is important for the Dec. and Jan. data where the calibration
2295 pulse position changes much.
2296
2297 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2298 filter. This corrects only an defective extraction of the MC at
2299 low-gain signals lower than 90 phes.
2300
2301 - fixed some slowdown in calibrating data with interleaved events from
2302 Jan and Dec. As a workaround made the pretty palette the default.
2303 The inverse Deep Blue Sea has a bug which slows down long calibration
2304 runs a lot.
2305
2306 - implemented new values from new starguider report as defined
2307 in TDAS00-07 V7.1 (eg SkyBrighness)
2308
2309 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2310 in starguider report (If you merpp the same reports with this version
2311 you'll get the correct units (arcmin) but a different result
2312 than with old versions (wrong units))
2313
2314 - Now the status display can also write PNG, JPEG and XPM (other file
2315 formats are still unsupported by root)
2316
2317 - added a lot of scripts and macros in directory datacenter used
2318 for automatic processing
2319
2320
2321
2322 *** Version 0.9 (2005/03/23)
2323
2324 - Calibration is now done autmatically into photo-electrons like
2325 decided by the Collaboration Board
2326
2327 - Reference lines in the display can be read from resource file
2328
2329 - Interlaced calibration events can be handled by callisto
2330
2331 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2332 and applied in callisto.
2333
2334 - class MJCalibTest can be called by callisto
2335
2336 - callisto can now run with three data types: rawdata, rootdata, MC
2337
2338 - added two classes mreport/MReportStarguider.cc and
2339 mreport/MReportStarguider.h for implementing starguider-data
2340
2341 - the output of merpp-update now contains starguider information:
2342 MReportStarguider and MTimeStarguider
2343
2344 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2345 values were lower than they should. This was more visible for high
2346 energy (Size) events.
2347
2348 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2349
2350 - added a new loop to callisto to support the correct extraction of
2351 the pedestal and pedestal rms through the signal extractor
2352
2353 - added class to perform fourier tranformation of a hexagonal structure
2354 (MHexagonalFT)
2355
2356 - added class to perform fourier tranformation of a hexagonal structure
2357 in a tasklist (MHexagonalFTCalc) example: hft.C
2358
2359 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2360 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2361 small pixels, example: extendcam.C
2362
2363 - added possibility to write data to memory (TTree) using MWriteRootFile
2364
2365 - added possibility to read a TTree stored only in memory by MReadTree
2366
2367 - new classes to deal with the interleaved calibration events:
2368 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2369
2370 - implemented filters to callisto to skip calibration events
2371
2372 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2373 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2374 the slices by statistics
2375 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2376 signal extractor without randomization
2377 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2378 with the signal extractor with randomization (extraction window is
2379 randomly fixed)
2380 The three kind of pedestal is not yet implemented (for speed reasons) as
2381 long as nobody really needs it:
2382 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2383 extracted with the signal extractor with randomization
2384
2385 - callisto now finds the pulse position in the data automatically
2386
2387 - implemented data reduction in calibrated data by reducing the precision
2388 of the stored floating point values (pedestal, rms and signal) to
2389 roughly 0.5%
2390
2391 - fixed showplot to make file format conversion (eg. converting a
2392 status display stored in a root file into a postscript file) in
2393 batch mode possible:
2394 showplot -b --save-as-ps[=outfile.ps] infile.root
2395
2396 - Allow class names as part of filter rules, eg
2397 (MFSupercuts) && (MHillas.fSize>100)
2398
2399 - fixed a lot of stuff to allow all programs to process MonteCarlo
2400 camera files.
2401
2402 - enhanced possibility to debug reading of resource file
2403
2404 - MDataChain should handle priorities of operator more
2405 accurate now
2406
2407 - completely revised the container in which the signal is stored
2408 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2409 * the new implementation is faster and
2410 * needs less storage space
2411
2412 - FIRST version which can process Monte Carlos through the
2413 whole chain of programs (callisto, star, etc)
2414
2415 - implemented new image parameters for the border length of
2416 the shower image (MNewImagePar2)
2417
2418 - implemented wobble-mode in ganymed
2419
2420 - new class (MJOptimize) taking care of all optimization processes
2421
2422
2423
2424 *** Version 0.8.6 (2004/10/05)
2425
2426 - New combined signal and time extractor
2427 MExtractTimeAndChargeDigitalFilter
2428
2429 - The Report for the trigger section in the CC run summary has been
2430 updated, and now the IPRs (Individual Pixel Rates) are available.
2431
2432 - new macros for database interaction: filldotrun.C, filldotrbk.C
2433
2434 - added new program which can convert colored output which was redirected
2435 into a file back into colored text (for example to display it with
2436 more): showlog
2437
2438 - added new program to display an MStatusArray of plots (stored with
2439 MStatusDisplay) from a file: showplot
2440
2441 - Added support for Sequences (MSequence). Sequences are blocks of run
2442 files containing the same calibration and belonging to the same
2443 source
2444
2445 - Added a new task (MTaskEnv) which can be used in setup files to switch
2446 between different tasks (for example to choose a signal extractor)
2447
2448 - Implemented automatic file splitting in MWriteRootFile
2449
2450 - After image cleaning an island index is assigned to all used pixels.
2451 The index corresponds to the order of the islands in size.
2452
2453 - added a cleaning which takes signal height _and_ arrival time into
2454 account: probability cleaning (for more details see MImgCleanStd)
2455
2456 - added a cleaning which takes takes the absolute number of photons
2457 times the area ratio as cleaning level
2458 (for more details see MImgCleanStd)
2459
2460 - Changed calculation of image parameters such, that it can be done
2461 for all used pixels or the pixels with a defined island index only
2462
2463 - implemented new image parameters displaying the number of islands,
2464 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2465
2466 - event display in executable changed to support also calibrated files
2467 (done with MJCalibrateSignal)
2468
2469 - added program doing the calibration and the signal extraction
2470 and signal calibration: callisto Most part of the setup is done
2471 by a resource file: callisto.rc
2472
2473 - implemented support for pixels with negative IDs (Raw file format
2474 version 4)
2475
2476 - implemented an new option in merpp (--auto-time) to get the time
2477 range for cc and/or caco data from the run header of the raw data
2478
2479 - New star-program (star and MJStar). Taking calibrated data from
2480 callisto/MJCalibrateSignal as input. The setup is done through
2481 a resource file: star.rc
2482
2483 - Added possibility to setup the eventloop in the mars-executable
2484 Camera Display by a resource file: mars.rc
2485
2486 - The the mars-executable Camera Display can now also read
2487 calibrated data files written by callisto/MJCalibrateSignal
2488
2489 - Added a new class which can calculate the source position in
2490 the camera from a pointing model known to be correct and
2491 the pointing model used for observations (MSrcPosFromModel)
2492
2493 - added a new version of the class calculating the effective on-time
2494 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2495 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2496 MHTimeDiffTheta.
2497
2498 - added the possibility to count how often a signal is above (or
2499 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2500 can replace MHTriggerLvl0)
2501
2502 - added ore convinient ways to set the axis-titles of your histograms
2503 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2504 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2505
2506
2507
2508 *** Version 0.8.5 (2004/08/06)
2509
2510 - new Signal Extractors: MExtractFixedWindowSpline
2511 and MExtractAmplitudeSpline
2512
2513 - implementes interleave in merpp to be able to merpp parts of a file
2514
2515 - implemented force-functionality to merpp
2516
2517 - star display to display star catalogs (MAstroCatalog)
2518
2519 - star display to 'mirror' stars to the camera (MAstroCamera)
2520
2521 - implemented a new cleaning option which allows cleaning scaled with
2522 the real ratio of the rms depending on the pixel size, not only the
2523 square root of the pixelsize (MImgCleanStd, MCameraData)
2524
2525 - removed obsolete MBlind* classes
2526
2527 - Signal extractor taking the AB flag into account implemented (this makes
2528 an odd number of slices for signal extraction possible
2529 (MExtractSignalABcorr)
2530
2531 - implemented a class extracting the pedestal from the raw-data (events)
2532 itself using empty lo-gain (MpedCalcFromLoGain)
2533
2534 - Added mean values to MPedPhotCam
2535
2536 - Added Makefile for Darwin (this OS is NOT officially supported!)
2537
2538
2539
2540 *** Version 0.8.4 (2004/04/19)
2541
2542 - new fast arrival time extractor using cubic splines:
2543 MExtractTimeFastSpline
2544
2545 - implementes multi-argument support in MDataChain
2546 ("pow(a, b)")
2547
2548 - implemented double reference support in MDataChain
2549 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2550
2551 - added support in MF for expressiond like
2552 "MHillas.fWidth<2*<MHillas.fLength"
2553
2554 - MDataChain is now able to support variables like [0], [1], ...
2555 which can be used in fit functions as parameters. The interface
2556 is implemented through the new virtual function
2557 MParContainer::SetVariables
2558
2559 - added new class MArrivalTimeCam/MArrivalTimePix:
2560 Storage containers to hold the ArrivalTime of the camera/pixel
2561
2562 - added new classes for the calibration of relative arrival times:
2563 MCalibrationRelTimePix and MCalibrationRelTimeCam
2564
2565 - added new classes to extract the signal of the blind pixel and the
2566 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2567
2568 - added new classes for the bad-pixels treatment (MBadPixels*)
2569 which are more powerfull than the old ones (MBlindPixel*)
2570 and will replace them.
2571
2572 - added filter against cosmics: MFCosmics
2573
2574 - added new class MArrivalTimeCalc2:
2575 Calculates the arrival time as the signal weighted mean of the time
2576 slices in the maximum window
2577
2578 - added a new macro call pointspreadfucntion.C that fits with a 2D
2579 gaussian the DC spot for an star. It gives you the RMS of
2580 the PSF and the center of the star, very useful for misspointing
2581 studies.
2582
2583 - added support for multi-telescope camera files. Added classes
2584 MStereoCalc and MStereoPar, classes to calculate and store shower
2585 parameters calculated from the data of two telescopes, for the MC
2586 studies regarding the MAGIC clone.
2587
2588 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2589 MC data calibrated in photons instead of ADC counts.
2590
2591 - added three macros to show the calibration and analysis chain of
2592 MC data. The macro starmc.C does both calibration and analysis, producing
2593 an output containing Hillas parameters for each event. The macro
2594 mccalibrate.C does just the calibration and writes out a file containing
2595 pixel information in photons instead of FADC data. The macro starmc2.C
2596 reads in such a file and produces an output with Hillas parameters.
2597
2598 - added MPedPhotCalc to compute pedestals in units of photons, see
2599 macro pedphotcalc.C
2600
2601 - added all class to perform the calibration, see macro calibration.C
2602
2603 - added class MFFT to perform Fast Fourier Transforms
2604
2605 - added class MSimulatedAnnealing to perform simulated annealing
2606 minimizations
2607
2608 - added new macro bootcampstandardanalysis.C which holds the skeleton
2609 of the analysis chain discussed in the december bootcamp.
2610
2611 - added support for DAQ raw data file format V2
2612
2613 - implemented an arbitrary time stamp for the events from raw-data
2614 files with file version<3. It is calculated from the run number,
2615 the date of start and the FADC clock tick from the first module
2616
2617 - implemented the correct decoding of the event time-stamp
2618 coming from the DAQ for raw-data files with file-version>2
2619
2620 - added a new classes storing the pedestals in units of photons:
2621 MPedPhotPix, MPedPhotCam
2622
2623 - added support for DC current files from the camera control
2624
2625 - added support for start- and stop-time when merpping report files
2626
2627 - added MReportCC storing the weather data from the CC-REPORT
2628
2629 - added class to fill trainings and test matrices (MTFillMatrix)
2630
2631 - added a filter performing a software trigger (MFSoftwareTrigger)
2632
2633 - Added classes to perform parts of the standard analysis (Jobs):
2634 + MJPedestals
2635 + MJCalibration
2636 + MJExtractSignal
2637 Note: All of them are preliminary!
2638
2639 - Added Iterator to iterate over files giving only the run-number
2640
2641 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2642 the evolution of a sector vs time
2643
2644
2645
2646 *** Version 0.8.3 (2003/12/05)
2647
2648 - adapted Random Forest classes to allow the use with MC
2649 multi-telescope files which can be produced with the coming
2650 camera version 0.7.
2651
2652 - added classes to read and interprete central control report files
2653 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2654
2655 - enhanced merpp (the executable) to support .raw and .rep files.
2656
2657 - added classes for light calibration (MCalibration* and
2658 MHCalibration*) by Markus Gaug. Further work has to be and will
2659 be done soon.
2660
2661 - Added a preliminary 'synchronizer' (MReadReports) which will
2662 replace MReadMarsFile as soon as it is finished.
2663
2664 - Added a tutorial macro demonstrating how report files are merpped
2665 and how they can be read from the root file in the correct order
2666 of time (readrep.C)
2667
2668 - Added a generalized histogram (similar to MH3) called MVsTime
2669 which allows to plot variables (or rules - MDataChain - of
2670 variables) vs time. For an example have a look at tempvstime.C.
2671
2672 - Changed the name of the event trees:
2673 + Events --> Events
2674 + PedEvents --> Pedestals
2675 + CalEvents --> Calibration
2676
2677 - changed name of MTime in the event trees from MRawEvtTime to MTime
2678
2679 - added displaying the sector indices to the mars event display
2680
2681 - Magic Online Analysis (MOnA) implemented in a first version
2682 (see mona.cc, MOnlineDump and MOnlineDisplay)
2683
2684 - added classes to calculate event rate
2685 (preliminary: MEventRateCalc, MEventRate)
2686
2687 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2688
2689 - added classes dealing with the telescope pointing position (MPointing*)
2690
2691 - implemented the 'final' Mars time stamp based on some experiences with
2692 the new 'Synchonizer'
2693
2694
2695
2696 *** Version 0.8.2 (2003/11/10)
2697
2698 - accelerated standard analysis by a factor of 6-8 ...
2699 + doing precalculations in MGeomCam for the pixel area ratio
2700 + creating a look up table for the single pixels in MCerPhotEvt
2701
2702 - added task to calculates weights in case you want to 'change'
2703 the energy spectrum of a monte carlo file
2704 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2705
2706 - added a new executable star which implements the
2707 star.C macro as precompiled executable. Currently a flexible
2708 setup is not possible, but a 'input card' setup will follow.
2709
2710 - Starting to implement Multi-Telescope-Support based on the
2711 upcomming camera version 0.7. The base for a general support
2712 is implemented and the star-functionality is proven to work.
2713
2714 - Replaced Event-Display in and Camera-Display in the Mars GUI
2715 executable by a more convinient display base on MStatusDisplay.
2716
2717 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2718
2719
2720
2721 *** Version 0.8.1 (2003/10/20)
2722
2723 - added signal subtraction for pure on data by means of fitting
2724 the background in the off region or by performing a combined
2725 signal/background fit. Provides necessary histograms for
2726 obtaining energy spectra and a light curve.
2727
2728 - added classes to perform and study the selection of the
2729 2nd Level Trigger on MC data (example in triglvl2.C macro)
2730
2731 - added pedestal calculation
2732
2733 - implemented "democratic cleaning" (tail cut value proportional
2734 to pixel area) according to Wolfgang's suggestion.
2735
2736 - added Sigmabar treatment (calculation and basic histogramming)
2737
2738 - added basic routines to apply padding
2739
2740 - added first implementation of MARS-based source visibility plotter
2741 (needs to be linked against slalib, preliminary version)
2742
2743 - enhanced functionality of data chains: random numbers, conversion
2744 functions and access to MHMatrix objects
2745
2746 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2747 numbers under certain circumstances (runs with 0 events included)
2748
2749 - fixed a bug in the general filter MF (didn't work on some systems
2750 at all)
2751
2752 - fixed a bug in chaining files, which caused the analysis to crash or
2753 ignore files
2754
2755 - implemented more geometry classes describing the parameters used
2756 to simulate the PMT camera
2757
2758 - added new Monte Carlo classes containing the setup of the different
2759 programs in the MC chain.
2760
2761 - added a (preliminary) general task to evaluate chi-square of a given
2762 parameter in an eventloop.
2763
2764 - first implementation of a container describing the observatory
2765 location (Long, Lat, etc)
2766
2767 - added Random Forest - method for g/h-separation
2768
2769 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2770 (this means, that it is compiling, but not yet fully tested)
2771
2772 - added a new status display which can show the present status
2773 of histograms while an eventloop is running (MStatusDisplay,
2774 an example can be found at status.C)
2775
2776 - reorganized directories:
2777 classes describing the image --> mimage
2778 classes containing Monte Carlo Histograms --> mhistmc
2779 classes for Random Forest method --> mranforest
2780
2781 - added (event-)weights to fill histograms
2782
2783 - colors in logging output to screen
2784
2785 - changes to the Image Parameter declaration:
2786 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2787 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2788 + MHillasExt now derives from MParContainer instead of MHillas
2789 --> Files written with the old definition are more or less unreadable
2790
2791 - reading of reflector files
2792
2793 - display data from reflector files in the camera
2794
2795 - implemented currents (and display them in the camera)
2796
2797 - logarithmic scale in camera
2798
2799 - added class to iterate through directory contents (MDirIter)
2800
2801
2802
2803 *** Version 0.8 (2002/11/18)
2804
2805 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2806
2807 - corrected 48(!) wrong entries in the Next Neighbor table of the
2808 Magic Camera (all in the inner part of the outer ring, mostly
2809 missing a single NN)
2810
2811 - Fixed a bug in the table describing the Next Neighbours of the
2812 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2813 have any neighbour)
2814
2815 - changed trigrate.C: now it calculates the pure NSB triggers from
2816 a camera file (generated with no showers), so there is no need
2817 to introduce them by hand in the BgR array (for more details
2818 please ask Abelardo)
2819
2820 - added MHHadronness (and MHadronness) as a general facility to evaluate
2821 the quality of a gamma-hadron seperation method
2822
2823 - changed MWriteAsciiFile to accept rules (MDataChain)
2824
2825 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2826 must be replaced by calles to MWriteAsciiFile::AddColumn and
2827 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2828 changed.
2829
2830 - Implemented generalized event-matrices (one row per event)
2831 (MHMatrix)
2832
2833 - implemented the one dimensional composite probabilities
2834 (MHCompProb, MCompProbCalc, comprob.C)
2835
2836 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2837 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2838
2839 - Added a camera display displaying the pixel numbers to the
2840 event display gui.
2841
2842 - Added Monte Carlo Informations to event display gui
2843
2844 - Changed the camera display to display the pixel numbering
2845
2846 - Added three buttons to the camera display to change the palette
2847
2848 - Added the number of used and core pixels after image cleaning
2849 to MHillas
2850
2851 - Changed the algorithm used in MHillas according to TDAS 02-03
2852
2853 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2854
2855 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2856
2857 - Added fCosDeltaAlpha to MHillasSrc
2858
2859 - The numbers of photons used to calculate fConc and fConc1 in
2860 MHillasExt are now scaled with the pixel size, so that one get
2861 a four times smaller value for the bigger pixels in the outer ring.
2862
2863 - added new task to smooth the camera contents (MCameraSmooth)
2864
2865 - added possibility to use interpolated pixel values for blind pixels
2866 instead of removing it completely from the analysis
2867
2868 - Implemented the possibility to save the whole eventloop with
2869 its setup to a file. This information can be read and from
2870 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2871 and MEvtLoop::MakeMacro. If you find something not working, please
2872 report - this stuff is still in a beta phase.
2873
2874 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2875 file having crab starfield, but also for all following files - fixed
2876
2877 - MTaskList::PrintStatistics can now be instructud to print also the
2878 title, too: use PrintStatistics(0, kTRUE)
2879
2880 - Changed the image cleaning so that pixels with to many 'used'
2881 neighbors are left used (to get rid of 'holes' in events)
2882
2883 - Introduced more output to the camera displays
2884
2885 - Added an array of histograms (eg one hist per run), MHArray
2886
2887 - Added a _preliminary_ version of the reader for CT1 PreProc files
2888 (MCT1ReadPreProc)
2889
2890 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2891 (thanks to Raquel)
2892
2893 - added the first energy estimator (MEnergyEstParam, estimate.C,
2894 estfit.C) using a parametrization
2895
2896 - Added some new Monte Carlo paremeter containers used to store
2897 setup information from the MC chain (MMcConfigRunHeader,
2898 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2899
2900
2901
2902 *** Version 0.7 (2002/04/30)
2903
2904 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2905 the pedestal mean value was saved incorrectly. For files from
2906 this versions we substract 0.5 from the pedestal mean.
2907 WARNING: This may effect your results, so don't wonder...
2908
2909 - First implementation of an algorithm using only triggered events
2910 for the collection area calculation
2911
2912 - Ascii Output can now also be used for parameter containers which
2913 doesn't overload MParCointainer::AsciiWrite
2914
2915 - The Ascii Output is now also capable of writing single data members
2916 of one container
2917
2918 - You are now able to change the order of the values written to the
2919 ascii file
2920
2921 - You can now specify a conversion factor for each data member written
2922 to an ascii file. This may be usefull to change the units of the
2923 data member (eg. degrees instead of millimeters in case of the
2924 hillas parameters)
2925
2926 - Replaced old MHillas by a new structure which allows you to extend
2927 the parameters stored in MHillas very easily:
2928 see MHillas and MHillasExt
2929
2930 - Added classes to handle source dependancy of image parameters:
2931 see MHillasSrc
2932
2933 - Added container (MBinning) to have a standard input for the binning
2934 in different histograms (eg. the Energy bins should be the same in
2935 all histograms)
2936
2937 - Changed Hillas histograms from mm to deg
2938
2939 - Added the flexible binning to the hillas histograms
2940
2941 - Added a filter for the alpha parameter (MFAlpha)
2942
2943 - It is now possible to write single data members of a class object to
2944 an output stream instead of the whole container only
2945
2946 - Added a generalized filter for a data member:
2947 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2948
2949 - Added a generalized Filter parser for more difficult filter rules
2950 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2951
2952 - Added new Monte Carlo histograms:
2953 MHMcEnergyImpact and MHMcEfficiency
2954
2955 - Added many new histograms needed for the flux calculation.
2956
2957 - Added a generalized histograms which can fill and show up to three
2958 data members in either a one-, two- or three-dimensional histogram, eg:
2959 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
2960
2961 - Added:
2962 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
2963 * calculation of <Theta> as a function of time (MHThetabarTime)
2964 they are needed in the flux calculation in
2965 order to select for a given bin in Theta (or time) the appropriate
2966 effective collection area, which is assumed to be given as a function
2967 of Theta and the true energy
2968
2969 - Added calculation of the migration matrix in the energy
2970 (MHMcEnergyMigration):
2971 the migration matrix describes the migration from the true (E_true)
2972 to the estimated energy (E_est); it is needed to determine the
2973 distribution of E_true from the measured distribution of E_est
2974 by unfolding
2975
2976 - changed the color palette in the camera display to DeapSea.
2977
2978
2979
2980 *** Version 0.6 (2002/01/15)
2981
2982 - Introduce the option of disable pixels (MBlindPixels and
2983 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
2984 able to deal with Star Field NSB.
2985
2986 - Fixed a bug in the pedestals substraction
2987
2988 - Introduced verbosity levels
2989
2990 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
2991
2992 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
2993 work correctly (thanks to Abelardo)
2994
2995 - Introduced correct treatment of the diffuse Night Sky Background
2996 and NSB (MMcPedestalNSB)
2997
2998 - Corrected treatment of the electronic noise (MMcPedestalCopy)
2999
3000 - Introduced MMcRunHeaders which contains monte carlo run informations
3001
3002 - Added a 'Print'-Task (MPrint) which calls the Print function
3003 of a parameter container for each event
3004
3005 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3006
3007 - changes to be more efficient with root 3.02/06
3008
3009 - root 3.02/06 fixes:
3010 + the memory leak when reading MRawEvtData
3011 + loosing more time than necessary to update the progress bar
3012
3013 - MWriteAsciiFile is now capable of writing more than one container
3014 in a line. For example: To be able to write Monte Carlo and
3015 Hillas values (energy and alpha) in one line.
3016
3017
3018
3019 *** Version 0.5 (2001/11/06)
3020
3021 - Added new GUI functionality (Analysis)
3022
3023 - Added a camera display to be able to display events in the camera
3024 together with the calculated hillas ellipse
3025
3026 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3027 object at any state of the analysis, so that the output are several
3028 states
3029
3030 - Fixed a bug in the collection area error calculation
3031 (Thanks to Ciro and Abelardo)
3032
3033 - Fixed a bug which causes merpp to crash in some environments
3034
3035 - Implemented auto enabling scheme for Branches to speed up reading
3036 a lot (see MReadTree and MTask)
3037
3038 - Fixed a bug in the Histogram classes which caused histograms to
3039 be written to a file by MWriteRootFile without request
3040
3041 - changed the object I/O from the old stylish root I/O to the new
3042 'auto evolution scheme' This was done only for classes which are not
3043 yet used in Monte Carlo files, so that these files are still readable.
3044
3045 - Added support for a progress bar in MEvtLoop and MReadTree
3046 (see the Analysis Window in Mars for an example)
3047
3048 - Fixed a bug in the package creation which disturbed the conversion
3049 between a mars version unpacked from a tar file and the repository.
3050
3051 - Changed the code to writer merpped (converted into root format)
3052 raw files, to get faster (around 10%)
3053
3054
3055
3056 *** Version 0.4 (2001/09/20)
3057
3058 - This release is made to compile on a root version >= 3.00
3059
3060 - Fixed a bug which causes MReadTree to read the first file only
3061
3062 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3063
3064 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3065
3066 - Added a task to write several container to a root file (MWriteRootFile)
3067
3068 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3069
3070 - Added calculation of the collection area (MMcCollectionAreaCalc)
3071
3072 - fixed some bugs in the Hillas calculation
3073
3074 - added filters to be able to control the task execution dependent on
3075 a parameter (for example: the number of level 1 triggers in a MC-file)
3076
3077
3078
3079 *** Version 0.3 (2001/04/23)
3080
3081 - Many demo macros added
3082
3083 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3084
3085 - Hillas Calculation added
3086
3087 - Standard image cleaning available
3088
3089 - MReadTree is now able to handle more than one file
3090 (Remark: of the same structure)
3091
3092 - Now we are able to display events in a first version of the
3093 Camera event display. To do this we must run the macro
3094 "macros/readCT1.C" to read data from CT1.
3095
3096
3097
3098 *** Version 0.2 (2001/01/24)
3099
3100 - First Implementation of a Gui to read the raw data. Start the
3101 gui with the command mars.
3102
3103
3104
3105 *** Version 0.1 (2000/12/20)
3106
3107 - First official release 0.1
3108
3109 - Changes:
3110
3111 + changed calling style of MRawPixelIterator from do...while to
3112 while-loop
Note: See TracBrowser for help on using the repository browser.