1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general
6
7 * fixed a few small bugs which could cause the display to crash in ganymed
8 and sponde
9
10 ;database
11
12 * plotdb.php: added default (sequences) for startup, added possibility
13 to set size of plot
14
15 ;merpp
16
17 * added support for Arehucas Version >= 200812140
18
19 ;ceres
20
21 * added a uniformly distributed one-bin time jitter for the start of the
22 digitization. Otherwise the first photon would be digitized always with
23 the same alignment to the bins
24
25 * Added a plot showing the production height of the photons
26
27 * Moved the particle id from the event header to the run header
28
29 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
30
31 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
32
33 * Added many new options to control the tasks. For deatils see ''ceres.rc''
34
35 * Removed obsolete plots in pedestal and calibration mode
36
37 * Removed the non-NightSky photons from the plots where they are just
38 disturbing
39
40 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
41
42 * The daq event number now represents the readout number
43
44
45
46== Version 2.2 (2009/01/30) ==
47
48 ;SUGGESTION
49
50 * This release doesn't contain a major change which is expected to
51 change your results. Nevertheless there are small changes to
52 the calibration which can effect at least the first few hundred
53 events in any (mainly MUX and even more SUM) sequence a little bit.
54 So it is recommended although not necessary to reset your sequences
55 in the database before further processing.
56
57 ;NEW
58
59 * A first implementation of a Monte Carlo simulation program
60 (ceres - Camera Electronics and REflector Simulation) has been
61 implemented. It can simulate a full telescope already including
62 a complete reflector simulation and a flexible trigger and readout
63 simulation. Currently, no perfect setup is implemented and
64 especially the output of the program (data structure) should
65 be considered alpha state. Also the user interface is not yet
66 ready.
67
68 ;general
69
70 * All command line options after -- are now interpreted as
71 arguments (usually everything which doesn't start with a minus)
72 rather than options (usually everything which starts with a
73 minus). This allows to use file names starting with a -
74
75 * In all resource files you can now initialize the random number
76 generator. For details see: MJob::InitRandomNumberGenerator
77
78 * added a new program called ''readcorsika''. It's purpose is (in analogy
79 to readraw and readdaq) to read a Corsika output file (for now
80 only cherenkov output is supported) and print its contents in a
81 human readable form. It can also write the contents of this file
82 into a root-file.
83
84 * The calculation of the maximum distance to the origin in a MGeomCam
85 has been improved (edges might be further away than the sides).
86 This is just a tiny change but it might change the appearance of
87 the radial profiles a little bit.
88
89 * The default binning of the center-of-gravity plot has slightly been
90 increased
91
92 ;Database
93
94 * Added informations about the DC currents (fMinCurrents, fMedCurrents
95 and fMaxCurrents). The values are retrieved from the plots showing
96 the average DC currents of all pixels versus time.
97
98 * Websites with tables have now the opportunity to remove lines
99 ('-' button at beginning of each line) and get all lines back
100 ('+' at top of the column)
101
102 * Websites: added option to query only sequences containing sumtrigger
103 events
104
105 * Websites: added option to group by date (year, month, night) for runs
106 and sequences and enabled that combining of different group-bys,
107 e.g. status, date and source is possible
108
109 ;automatic analyis
110
111 * Rewritten producing plots in the web.
112 New plots, namely the output of plotoptical.C (extinction curve from
113 KVA), plotstat.C (status of the automatic analysis (percentage of
114 processed, analysed data etc.)) and plotusage.C (statistics of the
115 condor usage in the data center) has been are available now next to the
116 plots of plotdb.C
117 Mean values from the plots (output of the macro) are provided in a
118 txt file now.
119 The creation of the plots for callisto, star and ganymed in the web is
120 now steered via database. Consequently the plots are faster and
121 reliable up-to-date.
122 For all plots, a new layout is available facilitating the browsing
123 through the plots and providing additional information on the
124 displayed values. (tabs.php) These plots are linked from the DB
125 websites and the wiki.
126
127 ;statusdisplay
128
129 * The ''Loop'' entry in the menu bar now contains an option to pause
130 the loop and to process single events.
131
132 ;merpp
133
134 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
135 instead of RunHeaders)
136
137 * Now allows to merpp files newer than 2008/09/03.
138
139 * Added fixes for wrong (wrong or double) run- and file-numbers
140 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
141
142 ;callisto
143
144 * Extracting the pulse position for the pulse position check events
145 with sum trigger were denied. This decreased the statistics
146 extremely and therefor the resulting puse position was calculated
147 quite weak. Now sum events pass the calculation if and only if they
148 have also a level 1 trigger.
149
150 * the extraction of pedestal events and pulse position from the
151 first data events is now more automatic and makes sure that
152 a more precise number of events is extracted independent of
153 the ratio with which pedestal events or events with signals
154 are contained in the data.
155
156 * Updated Muon calibration constants for all MUX data (teh changes were
157 all smaller than 5%)
158
159 ;star
160
161 * For the calculation of the effective on time all sum-triggered events
162 were skipped. Now all Level1-triggeres events will pass. This might
163 result in a slight inaccuracy of the effective on time.
164
165 ;ganymed
166
167 * If the source position is more than 1deg away from the camera
168 center an error is raised now.
169
170 * Hopefully fixed the bug ''ganymed crashes when resized''
171
172 ;sponde
173
174 * Fixed a problem which causes the fitted spectral slope to be displayed
175 incorrectly. If you use MJSpectrum::FormFlux in your macros make
176 sure that the parameter 0 of your fit is negative.
177
178 * Added a histogram showing the read source position of your MCs
179
180
181
182== Version 2.1.1 (2008/08/04) ==
183
184 ;Database
185
186 * Added the median number of photo electrons from the calibration
187 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
188 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
189
190 * Added fTotOnTime, which is the on-time as given by the run-headers
191 (in contradiction to fAbsOnTime which comes from CC)
192
193 * Added new primaries for the new data structure (Magic II): for the
194 tables dealing with sequences (SequenceBuild Status, Sequences,
195 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
196 this is the telescope number (fTelescopeNumber) for the tables dealing
197 with runs (RunData and RunProcessStatus) this is in addition the file
198 number (fFileNumber)
199
200 * Added column fPriority to the status tables to be able to steer the order
201 in which the data is processed. As default the run, sequence and dataset
202 number are used.
203
204 ;automatic analyis
205
206 * Adapted scripts to the new data structure: They can handle now different
207 telescopes (getting the information as usual from the database).
208 The paths for Magic 2 are not yet implemented.
209
210 ;general
211
212 * should work now with root 5.20/00 (please note that root 5.20/00
213 we encounter crahses in the status display which are ot yet
214 understood)
215
216 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
217 instead of the base name of the file. This makes them easier to
218 access from the code
219
220 * Default Monte Carlo names in MSequence do not require the _E at
221 the end anymore
222
223 * where abrrevating a sequence file with a sequence number is possible
224 also "telescope:sequence" is now accepted, e.g.:
225 star 2:2000123 --out=output
226 see the programs' help for more details.
227
228 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
229 from the database. See the constructors for more details.
230
231 * MReadTree now supports friends
232
233 * MReadTree can now read also files not written by MARS and store
234 the data encapsulated in emulated MParContainers
235
236 * added a new starguider calibration valid since 15.1.08
237
238 ;showplot
239
240 * showplot can now read more than one file at once. This is especially
241 inetersting if reading files containing pure canvases
242
243 ;merpp
244
245 * we merpp the dc currents now also from the camera reports (they have
246 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
247
248 * In the automatic analysis we omit merpping of the currents from the
249 caco files and use the lower rate camera reports from the cc files
250 instead
251
252 * merpp has been redisigned to allow merpping of the cc-reports
253 of a whole sequence. This allows to design a very simple analysis:
254 mkdir output
255 ./callisto 100776 --out=output
256 ./merpp 100776 output
257 ./star 100776 --ind=output --out=output
258 Instead of the sequence number also sequence files are accepted.
259
260 * Implemented a fix for run-numbers between 1001348 and 1001396
261 which were incorrectly assigned by the cc.
262
263
264 ;callisto
265
266 * added a filter again which was was removed in the last release.
267 it removed the most brightest events. This should not change
268 any analysis result because these events are so bright that
269 they cannot be analysed anyway, but the bad-pixel plots doesn't
270 show outliers.
271
272 * updated muon calibration constants for the periods 51-57,
273 58-63 and 67-
274
275 ;star
276
277 * The camera currents are now displayed with the rate of the camera
278 reports instead of the caco reports
279
280 ;ganymed
281
282 * if mc camera files are new enough (>=8) the source position in the
283 camera is now calculated from the stored telscope and shower
284 orientation (Note, that this might not be suitable in all cases
285 depending on the aim of the study. These case still needs
286 implementation)
287
288
289
290== Version 2.1 (2008/06/18) ==
291
292 ;Database
293
294 * introduced average temperature and wind speed from star-files
295
296 * introduced average values from Pyrometer (mainly Cloudiness)
297
298 * introduced the ratio of accepted calibration events in the
299 calibration run
300
301 * introduced the average rates of the different trigger pattern,
302 e.g. the rate of pedestal and calibration events, from the signal-file
303
304 ;general
305
306 * fixed GroupBy options in plot*.C macros
307
308 * only display KVA points (not the Tuorla points) in plotoptical.C
309
310 * all programs now allow to add resources to the ones from the resource
311 file or overwrite them from the command line. This can be done like this
312 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
313 if something seems to be wrong you can debug what the program is doing
314 using the option --debug-env=3
315
316 * increased the diversity of debug levels. That also means that with -v3
317 you get now less output, i.e. only the output which is important for
318 an analysis. To get more output which helps for debugging try 4, 5 and 6.
319
320 * fixed a problem in the task synchronizing the reading of the reports
321 and the data stream. The effect was that in some circumstances the last
322 events of some trees could have been skipped. Since this is only a
323 very tiny part of the data no severe effect to your analysis results
324 is expected (an exception might be very short, i.e. singel runs,
325 datasets).
326
327 * Dataset file now allow to include the sequence file directly within
328 the dataset file and also allow to exclude single runs from the dataset.
329 (for more details see Class reference of MDataSet)
330
331 * Sequence files now allow for excluding runs from the analysis
332 (for more details see Class reference of MSequence)
333
334 * added code to process the sum-trigger flag
335
336 * the histogram classes MH3 and MHn now support profile histograms
337
338 * the histogram classes MH3 and MHn now support labels at the axis
339
340 * the Random Forest Train-classes (MJTRain*) now store the used datasets
341 in the output file
342
343 * the MFMagicCuts have a new option to allow a linear area cut (for
344 special studies)
345
346 * The liniking of the shared object is now done into a file defined
347 by 'mktemp'. This should be a local file system which accelerates
348 liniking a lot.
349
350 * The code has been prepared for compilation with root 5.18/00d
351
352 * The MHEnergyEst histogram now shows the distribution of
353 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
354 and (Eest-Emc)/Emc vs Emc.
355
356 * fixed mars (event display) for merpped raw-data and MC data
357
358 * adapted the synatx of sequence files to allow for the new run/file
359 scheme. For more details see class description of MSequence
360
361 ;showplot
362
363 * Added support for tiff files
364
365 * Added support for csv files (tables containing tab number,
366 name and title)
367
368 * Tabs now can have a title which is displayed in the postscript file
369
370 * When multiple file are written at once (e.g. pngs from a display)
371 it is now possible to use the tab name and or tab number in the
372 file name. For details see showplos's help.
373
374 ;merpp
375
376 * Implemented cc file version 2008-02-20/0
377
378 * Implemented cc file version 2008-05-19/0
379
380 * With new options merpping can be restricted (in addition to the
381 run-number) also by telescope and file number.
382 For details see "merpp --help"
383
384 * Implemented raw data format 11 (the most important change, except
385 from plenty of changes in the format definition, is the addition
386 of the file-number in the header) If nobody makes a mistake this
387 format should have the advantage that it is by definition forward
388 compatible, so old programs will be able to read newer formats.
389
390 * Added Pyrometer information to default output (stored in a new Tree
391 Pyrometer, needs a complete new merpp, i.e. new calibration)
392
393 * Merpping (also update) can now be restricted to one single report.
394 For example:
395 If you want to update an old file with Pyrometer information call
396 merpp --only=Pyrometer --update
397
398 ;callisto
399
400 * in the pedestal processing now at least 50 processed events are
401 required for succeeding.
402
403 * the signal and calib files now contain also the sequence information
404
405 * the two MPedestalCam in the calib file now have proper names
406 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
407
408 * Both pedestal cams now contain the number of events processed
409
410 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
411 i.e. for the extraction of the calibration pulses basically the average
412 over all events of the first slice instead of all slices was used.
413 Since pedestal and calibration constants are continously recalculated
414 this only effected the very first events of every sequence.
415
416 * For the extraction of the position of the maximum sample now the
417 extraction range is set automatically to the extraction window,
418 before the whole accessible range was used.
419
420 * If the number of samples in the events and the number of samples
421 in the run-header disagrees now an error is raised (this can
422 happen in not well simulated Monte Carlo files)
423
424 * In the case of MUX-data pedestal events with the lvl1 trigger flag
425 could survive into the pedestal calculation -- fixed.
426
427 * Tab "TrigPat" added showing the distribution of the trigger pattern
428 as found in the run-files (normalized with the run length)
429
430 * The selection of events from the trigger pattern has been improved.
431 If the trigger pattern is corrupted events won't pass anymore.
432
433 * Added a new command line option --dev-null to suppress output of
434 Y-files (this is useful for test cases)
435
436 * added a new tab "CalPos" showing the arrival time of extracted
437 interleaved calibration events
438
439 ;star
440
441 * the star file now contains also the sequence information
442
443 * Added a new command line option --dev-null to suppress output of
444 I-files (this is useful for test cases)
445
446 * Tab "Rate" added showing the distribution of the trigger pattern
447 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
448 the Y-files (normalized with the run length)
449
450 * The effective on-time calculation doesn't use events with only
451 sum-trigger anymore
452
453 * The data in the MHWeather tab has been reorganized. The never
454 working solar radiation has been removed and the data from
455 the pyrometer (cloudiness, air and sky temperature) is
456 displayed in addition.
457
458 ;ganymed/sponde
459
460 * Now data points are even shown correctly if they have error bars larger
461 than one sigma. Points with null or negative significances are omitted.
462
463 * DrawNicePlot now allows to set a projection range
464
465 * Updates pointing models. One is applied after the implementation
466 of the new LUTS in August, the other one is applied after the
467 next major change of the pointing model in October. Note that
468 these models are preliminary and give wrong results below Zd=65deg
469
470 ;sponde
471
472 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
473
474 * a new option "--force-runtime" is available. In case of very short
475 datasets (for light-curves) which are in the order of a few
476 minutes the calculated effective on-time is not very acurate because
477 it is quantizised in the order of a minute. Therefore you can switch
478 to using the real run-time instead (remakrt: this ignores any
479 dead-time!)
480
481 * a more analytical way is used to "fill" Monte Carlos into regions
482 of impact parameters which have not been simulated because the
483 trigger efficiency is assumed to be 0.
484
485 * estimated sensitivity curves for hi and lo zenith angles are shown
486 scaled to the correct observation time and collection area
487
488 * the Monte Carlo events after cuts are now written to the output file
489 if an output file given
490
491
492
493 *** Version 2.0 (2007/09/03)
494
495 - database: the position used for the pulse pos check was missing
496 in the callisto output and could thus not be filled into the DB.
497 Also the old values seemed not exactly the PulsePos used for
498 teh check.
499
500 - general: Resource file now allow an Include-Resource, i.e. you can
501 read a resource file with default settings, include it in your
502 resource file and overwrite the settings in your file. More than
503 one include file is allowed. Inclusions can be iterative.
504 Include: mydefaults.rc yourdefaults.rc
505 The resources in the first file have higher priority than the
506 second file.
507
508 - general: Now the output files (calib*.root, etc) also contain the
509 resource file (to check it open it in the TBrowser and choose Print()
510 from the context menu)
511
512 - general: Dataset files now allow to overwrite the default path
513 to search for sequence and data files. Note, that the program
514 option and individual resources will overwrite it. For example:
515 SequencePath: /magic/montecarlo/sequences
516 DataPath: /magic/montecarlo/star
517
518 - general: Fixed a problem with variables in MDataPhrase. It seems
519 that only optimdisp (didn't work) was effected.
520
521 - general: Some improvements to the optim and train processing. For
522 example the ststud window now got a proper title.
523
524 - general: The "Status Display: " was removed from the window title
525 within an Eventloop.
526
527 - general: added a new flexible histogram-class (MHn) which can be used
528 for example in testing after optimizations or training to produce
529 user defined histograms.
530
531 - general: The Random Forest now allows attaching an evaluation
532 function which is applied to its output. This allows to train
533 on whatever you like (eg. train on log10(energy), but return
534 energy)
535
536 - general: The Random Forest training of energy (trainenergy.c) and
537 disp (traindisp.C) has been improved by more graphical output to
538 judge the result.
539
540 - general: The training of energy (trainenergy.C) has been improved
541 a lot by training on a different quantity than energy. It gives
542 a result which is highly independant of the source spectrum
543 and shows lower bias than all other options.
544
545 - general: Dataset files are allowed to contain collections of
546 datasets. For more details see the class reference of MDataSet.
547
548 - general: The default WobbleMode in a datset file now (if not
549 overwritten) is "auto", i.e. wobble mode is set if the dataset
550 doesn't contain off-sequences.
551
552 - merpp: Merpp can read file format version 9 now. Please realize
553 that for file format version 9 the extraction range is different
554 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
555 the first and last 15 slices have been removed from all MUX data.
556
557 - mars: Similar to writing movies you can now select events which
558 should be displayed in your display. Therefore add the following
559 lines to your mars.rc:
560 MFEvtNumber.FileName: ganymed00223552.root
561 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
562 The input file can be a ganymed-file after (ganymed*.root) or
563 before (ganymed*-summary.root) file. For example to select all events
564 from your on sample after cuts (excluding the ThetaSq cut) use
565 MFEvtNumber.Selector: DataType.fVal>0.5
566 To show all events from your on-sample after quality cuts
567 use the summary file instead.
568
569 - mars: new ways to call mars are implemented. Instead
570 of calling
571 mars filename.root
572 you can now also use
573 mars sequence.txt
574 or
575 mars sequence.txt inputpath
576 or replace sequence.txt by the sequence number if the default
577 sequence file should be used.
578
579 - mars: The default size has been increased
580
581 - mars: There are two new heckboxes which allow to switch off
582 the calculated image parameters
583
584 - callisto: was broken for MCs... fixed.
585
586 - callisto: improved calculation of spline coefficients a lot. This
587 leads to a further improvement of the event rate calibrating MUX
588 data of about 15% (175evt/s instead of 150evt/s)
589
590 - callisto: finally the raw data we read is now real 16bit (with
591 10bit precision) for MUX data and not a stripped 8bit number
592 anymore. Due to scaling of the numbers (without precision loss
593 into an [0-256[ range, the final numbers for pedestal, pedestalrms
594 and extacted signal don't change. However, at all places where
595 raw data is directly accessed (eg. saturation and variation
596 limits in the signal- and pedestal-extraction) the numbers
597 refer still to the data's 16bit range.
598
599 - callisto: The maximum arrival time difference used in the bad
600 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
601 for both, old FADC and MUX-FADC, data.
602
603 - callisto: Be aware that callisto is now calibrating the arrival time
604 in nanoseconds rather than time slices. Also all following tasks
605 have been changed to assume ns units now. If you star data
606 calibrated with an older version it might be necessary to adapt
607 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
608 to obtain optimal results. The plot in the PulsePos tab
609 will now be in ns, too. This might also mean that the Muon
610 analysis in star might not work as perfect as expected as long
611 as old files read in.
612
613 - callisto: The calibration constants of earlier updates got lost
614 somehow. All constants have been updated.
615
616 - star: The PSF is now determined from the profile of the ArcWidth
617 instead of arcwidth/radius. The old way gave to much weight
618 to the bins with low statistics. The reference lines have been
619 updated.
620
621 - star: For speed reasons events suitable for the muon analysis
622 are now also preselected by fConcCOG<0.1 which seems to be a very
623 good preselector for muons.
624
625 - star: is now calculating a new timing parameter the Slope along
626 the major and minor axis of the shower. Therefore a numerical
627 solution of a line-fit is used. To use MHillasExt.fSlopeLong
628 and MHillasExt.fSlopeTrans don't forget to multiply it with
629 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
630
631 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
632 have been removed from MNewImagePar. They have never been good for
633 anything.
634
635 - star: Implemented a new recursive algorithm which is supposed to be
636 faster. Also implemented new cleaning oiptions, which are:
637 + CleanLevel0:
638 The cleaning level above single core pixels can be kept
639 + KeepIsolatedPixels:
640 Define whether single core pixels should be kept
641 + TimeLevel1:
642 The coincidence window in nanoseconds to single used neighbors
643 + TimeLevel2:
644 The coincidence window in nanoseconds to two used neighbors
645 + PostCleanType:
646 MOde in which a time dependent post cleaning should be applied
647 0: No post cleaning
648 1: Require for each used pixels at least one used neighbor
649 within a time-window of CleanLevel1
650 2: Require for each used pixels at least two used neighbor
651 within a time-window of CleanLevel2
652 3: Require first two and second one used neighbor
653 within a time-window of CleanLevel1 and fCleanLevel2
654 respectively
655 + RecoverIsolatedPixels:
656 - recoveres isolated core pixels if they have a used neighbor
657
658 - mars/star: The new default cleaning is:
659 + CleanLevel1: 6.0
660 + CleanLevel2: 3.0
661 + CleanTime1: 1.75
662 + CleanTime2: 1.75
663 + PostCleanType: 3
664
665 - star/ganymed: The old spark-cuts have been replaced by new ones.
666 These new spark cuts have been cross checked with the sequences
667 84720 (before splitter), 101041 (after splitter) and 223539 (new
668 FADCs). In all cases they seperate pretty well, but of course not
669 perfect. Monte Carlos have suggested to tighten the cuts a little
670 bit further at low sizes. This has been done.
671
672 - ganymed: IMPORTANT - The spark cuts have been changed to match
673 all available data more or less well. This might mean that for
674 YOUR data there are still sparks visible.
675 Whenever you do an analysis you have to make sure that NO sparks
676 survive your cuts!
677
678 - ganymed: The old hadronness and size cuts have gotten new indices
679 (10, 11). The old indices 8 and 9 now mean an additional condition
680 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
681 If you want to switch off this cut just move the line far away enough,
682 e.g. by setting c[9] to -500. Please update your ganymed.rc files
683 accordingly!
684 The unit of c[9] is deg. It is the dist at which your cut will
685 cross the slope==0. The unit of the slope is ns/deg. So if
686 you readin files calibrated with an older Mars-version you
687 have to adapt the default value for c[9] to the FADCs:
688 - Multiply by two for the MUX FADCs (run number > 200.000)
689 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
690 - Multiply by 42 for the meaning of life (run number = 200.000)
691
692 - ganymed: The old Cut0 is now called CutQ and is calculated before
693 the source position is caluclated. If you need a quality cut
694 including source dependant data (be very carefull with this!)
695 you have to use Cut0 instead.
696
697 - ganymed: now properly supports three off regions in wobble mode.
698 It will be the default from now on in ganymed_wobble.rc. To change
699 the number of off-regions use
700 NumOffSourcePositions: 1
701 in your ganymed.rc. Also by default no off-theta cut will be done
702 anymore so that you will get a background level higher than the
703 signal level in your ThetaSq plot for ThetaSq>0.2.
704 Due to this be carefull changing the scaling mode away from
705 "None". You will underestimate your signal if your scale interval
706 is not properly set.
707 (Rem: ThetaSqN is no longer needed)
708
709 - ganymed: is now storing the events of all (on- and off-)
710 source positions even in the case of more than one off-source
711 position. This should allow sponde to work properly and the
712 energy estimation is done correctly in all cases (without any
713 "nearest position" trick)
714
715 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
716 with a real pointing model for the starguider is done, calibrated
717 with more than thousand tpoints taken from this date on.
718
719 - ganymed: was broken for Wobble-MCs... fixed.
720
721 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
722 has changed. Note that your old ganymed.rc will be incompatible
723 with the new algorithms! Please check the ganymed.rc files and
724 the class description of MFMagicCuts for more information.
725 It is recommended at the moment to use identical Disp-Parametrizations
726 for on/off- and wobble-mode. If cuts are optimized only
727 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
728 should be optimized. All other values should be kept as they are.
729 If you want to do an anylsis without timing a parameters, you can
730 switch off the timing cuts by seeting parameter 7 to a very small
731 value (eg. -99). To remove the slope parameter from the disp
732 paremtrization set parameter 8 to 0.
733
734 - ganymed: The distribution of observation time versus zenith
735 angle is now shown for off- AND on-data.
736
737 - ganymed: The contents of the source position plot are no longer
738 averaged, thus a lot of (fake) events between the two wobble
739 positions have disappeared.
740
741 - ganymed: There is a new tab "CutT" it contains the VsSize plots
742 with the CutT, whihc is defined in ganymed.rc, applied. It
743 is resonable to use your theta-cut for it, to see if there is
744 something strange (sparks!) in your signal-region.
745
746 - ganymed: To choose a dataset from a collection in a dataset file
747 use the new command line option "--dataset=12345"
748
749 - optim, sponde: should now properly support three off-regions.
750 Just produce your ganymed summary files with three off-regions.
751 optim and sponde will automatically get all off events from
752 all off-regions from this file. Please do not forget to
753 set the scaling in optimwobble.C properly:
754 fit.SetScaleUser(1./3);
755 it is not yet read in automatically (will follow soon).
756 In the case of fixed Scale you can also use
757 cuts.SetThetaCut(MFMagicCuts::kOn);
758 no off-cut needed.
759 Be carefull in case of three off-regions when switching on
760 scale mode. Make sure that the scale interval is set correctly.
761
762 - sponde: sponde.rc and sponde_onoff.rc are now idetical
763
764 - sponde: the resouce files have been rewritten with a lot of
765 comments and a well working parametrization for an energy estimator
766
767 - sponde: In the estimated energy versus monte carlo energy plot the
768 contents where exchanged.... fixed.
769
770 - sponde: the so called "accurate"-mode has been removed. It didn't
771 give any improvement in accuracy, only decreased execution speed.
772
773 - sponde: the so called "simple"-mode has been removed. It didn't
774 give any improvement in simple.
775
776 - sponde: the so called "refill"-mode has been removed. It was anyhow
777 not implemented.
778
779 - sponde: now checks whether the theta distribution of your on-data
780 and the theta-distribution of your Monte Carlo sample (after
781 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
782 sample is incomplete) execution is stopped. Execution can be forced
783 using the new option --force-theta. Use this option with care!
784
785 - sponde: Proper collection areas can now be constructed also from
786 Monte Carlo samples generated with different maximum impact
787 parameters. Note that in previous version you neither got
788 a warning or failure, nor was there any obvious sign that the
789 collection area was overestimated due to usage of files with
790 different maximum impact parameters.
791
792 - sponde: If MC files with different lower energy limits are used
793 the primary MC spectrum is artificially completed down to the
794 lowest energy used at all. WARNING: that this gives correct
795 collection areas ONLY if none of the events in this region would
796 survive your cuts at all.
797
798 - sponde: the output file now contains more information about
799 the spectrum (eg. the full 2D collection area histogram).
800 Note, that this information can only be written to the file
801 if it is stored automatically via command line argument.
802 If you only store the status display from within the display
803 the information is lost.
804
805 - sponde: added a new tab "Disp". It shows the residual of the disp
806 (Disp-Dist) versus several parameters and it is meant to judge the
807 quality of the disp estimator. In the ideal case the residual is zero
808 and doesn't depend on any variable. The tab is displayed after
809 CutQ and Cut0.
810
811 - sponde: added a new tab "Energy". It shows the residual of the
812 energy (lg(estimated energy)-lg(monte carlo energy)) versus
813 several parameters and it is meant to judge the quality of the
814 energy estimator. In the ideal case the residual is zero
815 and doesn't depend on any variable. In reality even a good estimator
816 can show residuals versus Monte Carlo energy. The tab is displayed
817 after all cuts.
818
819 - sponde: added a new tab "EventDist" showing the unweighted real
820 absolute number of events of your sample after cuts. This tells
821 you how many events with this energy you had in your MC files.
822 The same information you get from the error bars of the weighted
823 histograms, but this is less intuitive.
824
825 - sponde: The spectrum plots now show the crab- and 1553-spectrum
826 for comparison. It is not meant to show these curves in
827 publications, they are only for production.
828
829 - sponde: The OriginalMC tree with the events produced by corsika
830 is now processed only once
831
832 - sponde: Finally fixed most annoying bug, which has effected the
833 last bin of the collection area. It was the problem that binnings
834 of root histograms are from 1 to n (included) but there was a C-like
835 loop in sponde from 0 to n (excluded). Now the loop also includes
836 correctly under- and overflow-bins. The worse thing with this is,
837 that for the events in the highest bin not only the bin-content
838 was wrong, but also the weights applied to these events, which could
839 in pricipal effect also other parts of the distribution (eg. due
840 to energy estimation). Fortunately it effected only a few events
841 in most cases.
842
843
844
845 *** Version 1.2 (2007/05/14)
846
847 - database: The database now has two new values Unsuitable50 and
848 Unsuitable01. They express the number of pixels which are
849 unsuitable for more than 50%, respectively more than 1%, of
850 all calibrated event. It is a more accurate number than the
851 previously used numbers, because they only take the first
852 calibration (ignoring the interleaved calibrations) into account.
853
854 - database: The database now has two other new values UnsuitableMax and
855 DeadMax. They express the maximum number of pixels which were
856 unsuitable, respectively dead, during the sequence. Because
857 of high pedestal rms (cars passing) a few events with very high
858 numbers of unsuitable pixels can happen. Not to suffer from this
859 effect we don't take the highest 0.1% of the numbers into account.
860
861 - general: fixed a bug which caused callisto and star to stop working
862 properly because the callisto output was currupted
863
864 - general: a script called scripts/makemovie has been added which
865 simplified the process of producing several movies from a single
866 sequence with different setup.
867
868 - callisto: Some more code cleanup. Started to remove old obsolete
869 code from cvs.
870
871 - callisto: The extraction of the pedestal with the extractor was
872 not random. It seems that extracting at one position is still biased
873 (for example in the first or last slices we could still suffer from
874 switching noise) Now it is completely random.
875
876 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
877 pedestal files) individual pixels could be skipped due to high
878 variations. This was already the case for the pedestal extraction
879 from the lo-gains since the beginning and properly handled
880 there, but was introduced in the extraction from the pedestal files
881 a while ago. To calculate the average value it was still divided
882 by the number of events procesed not by the number of summands
883 really summed. This let to a pedestal which was a tiny amount too
884 small (for a few piels in the order of 0.1%). This led to an slightly
885 positive offset of the randomly extracted pedestal for a few pixels.
886 I doubt that this has a big effect on the result, because the effect
887 on the individual numbers is quite small. Due to this it is suggested
888 that you rerun your calibration to make sure you are without any
889 avoidable bias.
890
891 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
892 the median rms of the absolute arrival time and expressed in significance
893 levels. This replaces the old meaning of an abolute upper limit. An
894 absolute upper limit doesn't make much sense, because in our data
895 all arrival times are shifted at the same time (in fact it might be
896 a shift of the artificial trigger w.r.t. to the light flash).
897
898 - callisto: Added a new tab "BadPixTm" which shows the time evolution
899 of the number of unsuitable pixels over the whole sequence. This
900 is usefull mainly to judge if an intermediate calibration had
901 problems.
902
903 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
904 of the number of dead pixels over the whole sequence. Dead pixels
905 in this context are unmapped pixels, i.e. pixels which could not
906 be interpolated, and thus are ignored in the further analysis.
907
908 - callisto: It is now possible to use the position of the maximum
909 of the spline as arrival time instead of the leading edge even
910 when using the integral for the signal. Therefor set the extraction
911 type to kIntegralRel ("IntegralRelative") and the relative height
912 ("HeightTm") to -1:
913 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
914 MJPedestalC1.ExtractSignal.HeightTm: -1
915
916
917
918
919 *** Version 1.1 (2007/04/27)
920
921 - general: The new class MGeomCamDwarf contains the camera geometry
922 for our prefered Dwarf camera and can be used to create general
923 geometries of roundish or hexagonal cameras.
924
925 - mars: The default cleaning is now abolute 8.5/4.0.
926
927 - mars: The resource file mars.rc now contains examples for MUX data
928
929 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
930 data containing only 10-bit information is still cooked down to
931 8-bit, by cutting away the lowest 8-bit.
932
933 - merpp: When reading raw data the data is now stored in a single
934 array. The lo-gain array is obsolete. The interface stays the same.
935
936 - callisto: To process the new MUX data use the resource file
937 callisto_mux.rc
938
939 - callisto: The -root and -raw options to read merpped raw data have
940 been removed
941
942 - callisto: If the -mc option is given the sequence-name can now be
943 replaced by the MC sequence number
944
945 - callisto: If the sequence file contains "MonteCarlo: Yes" the
946 -mc option can now be omitted
947
948 - callisto: Started further simplification by removing obsolete
949 dependancies on MCalibIntensity*Cams.
950
951 - callisto: removed unsused intensity calibration from MJCalibration
952 for further simplification
953
954 - callisto: for simplification removed references to
955 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
956 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
957 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
958 (this should at minimum change nothing at all, and at maximum
959 improve thing if these containers where somewhere not handled
960 properly)
961
962 - callisto: Added the option to write an event movie. Please use
963 this option with care (huge files) but exessively to understand
964 our events. For further documentation please refer to the
965 IACT wiki
966 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
967
968 - callisto: Improved binning for the pulse position check histogram
969
970 - callisto: The code calculating the pulse position checknow takes
971 the pedestal into account
972
973 - callisto: The arrival time is now stored with full precision this
974 helps to get rid of artefacts in histograms. For the signal this
975 is not necessray because it is displayed in log-scale anyhow
976
977 - callisto: Fixed a problem with internal exclusions. Pixels which
978 have once been marked as unsuitable didn't get the necessary
979 histograms filled anymore to be rechecked with each interleaved
980 calibration.
981
982 - callisto: The relative arrival time resolution (the rms of the
983 relative arrival time offset) is now checked against its
984 median and the median deviation, instead of the average
985 plus an absolute offset.
986
987 - callisto: The relative arrival time offset is now calculated
988 w.r.t. its median not w.r.t. to an artificial reference pixel.
989
990 - callisto: The relative time calibration now marks pixels with
991 outlaying offset as unsuitable
992
993 - callisto: The interleaved relative time calibration has been switched
994 on. The advantage is that pixels which are marked as outliers
995 now can recover. An improvement over time is not expected, because
996 the relative time calibration seems stable.
997
998 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
999 option can now be omitted.
1000
1001 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1002 or the option "-mc" is specified as default the monte carlo datacenter
1003 paths (/magic/montecarlo/...) are used if not overwritten in the
1004 dataset file.
1005
1006 - ganymed: The output files now contain run- and event-number for all
1007 events, accessible as RunNumber.fVal and EvtNumber.fVal
1008
1009 - ganymed: Added a plot showing the source position in the camera also
1010 for wobble mode
1011
1012 - ganymed: In addition to the existing task which can be setup to
1013 be executed after Cut1 a final task called "EstimateEnergy"
1014 has been added, executed before writing the final output
1015 (ganymed00000000.root). The task setup in all three cases
1016 can be choosen individually. (For all three(!) cases you
1017 can for example choose MRanForestCalc. For examples see all
1018 sponde*.rc and all ganymed*rc)
1019
1020 - ganymed: If a container "MEstimatedEnergy" is found in the
1021 parameter list (eg. because it was setup by MEstimateEnergy)
1022 it will be written to the output file.
1023
1024
1025
1026 *** Version 1.0 (2007/02/16)
1027
1028 - database: Website to plot values from the database has been added.
1029
1030 - database: The rate of spark events as found by star is now kept
1031 and the rate after cleaning is now with spark events subtracted
1032
1033 - general: The changes to the interpretation of phrases lead to
1034 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1035
1036 - general: Added example files how you can create your own calendar
1037 (eg. as christmas present) with Mars. Just run
1038 root macros/tutorials/calendar.C
1039
1040 - general: Added a possibility to display grouped data in the plotdb.C
1041 macro (and similar macros). This allows to plot hourly, nightly,
1042 weekly, monthly and yearly averages.
1043 For more details see the plotall function of the macro
1044
1045 - general: fixed the error display of the camera display. It showed
1046 wrong results.
1047
1048 - general: fixed a memory leak when reading many MStatusDisplays
1049
1050 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1051 between a spherical and a parabolic mirror
1052
1053 - callisto: We have a new pulse position check which takes the properties
1054 of the extractor automatically into account. So no need to set
1055 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1056 left is done. If possible the lo-gain extraction start and hi-gain
1057 extraction end is changed accordingly. If no proper extraction range
1058 can be set (hi-gain too much to the left) an error is raised.
1059
1060 - callisto: New swapped pixels have been found and corrected
1061
1062 - callisto: Redone the signal extraction this includes:
1063 + Unified the algorithms to extract the pedestal for all pedestal
1064 extractions done
1065 + Unification of hi- and lo-gain into one array
1066 + Unification of hi- and lo-gain extraction for Spline and
1067 Digital Filter (means now exactly the same algorithm is used,
1068 not a copy-and-pasted one)
1069 + Store pedestal subtracted data in a common place
1070 + Improved extraction algorithms. If the algorithms search a
1071 maximum but don't find one they don't return the maximum anymore
1072 + Improved the extraction such that a information for signal
1073 and time which is consistent is returned
1074 + replaced the numerical spline with a (not slower) analytical
1075 solution
1076 + Lowered the saturation limit from 250 to 245 to make sure that
1077 we are far away in all pixels from problems with the clock-noise
1078 + The start of the lo-gain extraction is calculated from the hi-gain
1079 arrival time. In case of saturation an estimation is used.
1080 + the hi-gain window was extended to slice 16. This allows extraction
1081 of very late pulses in single pixels or of huge hadron showers.
1082 + Now uses the lo-gain extraction range for pedestal extraction,
1083 not the hi-gain range in the lo-gain
1084
1085 - callisto: New hi-/lo-gain calibration constants have been produced
1086 for all periods from the statistic of the whole period. They are
1087 now used automatically depending on the periods. The old constants
1088 where deviation in avarega about 2%-3%. The constants are very
1089 stable from period to period (<<1%) except for exchanged channels.
1090 In a few cases the constants used so far were off by 1%-2% (maybe
1091 temperature effects?)
1092
1093 - callisto: To gain obsolete space we do not write the
1094 MPedestalFundamental anymore. Also calibration and bad pixel
1095 treatment is not done for it anymore because it has never been used.
1096
1097 - callisto: Fixed a bug in the seuqence handling which caused the
1098 light condition to be ignored
1099
1100 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1101 basically the same as "Cleaned" but the distribution devided into
1102 the events fullfilling a spark cut or being rejected by it.
1103 This cut can be changed from star.rc (see example inside) by
1104 the "SparkCut" directive
1105
1106 - star: Star displays now the average individual pixel-rate (IPR) versus
1107 time and the average discriminator threshold (DT) of all pixels.
1108
1109 - optim: fixed a problem with the optim-macros which was due to a bug
1110 in the new phrase parsing
1111
1112 - ganymed: To get a nice FalseSource plot (instead of the all-information
1113 debug plot displayed as a standard plot) use the context menu
1114 somewhere between the two upper plots, click on "DrawNicePlot"
1115 and enjoy the result. (It is the same context menu which contains
1116 the other options)
1117 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1118
1119 - ganymed/optim/train: The cut program, trainings- and optimization
1120 macros could run with less files found than expected from the
1121 sequence-files. No the execution is stopped in this case.
1122
1123 - ganymed: now stores the dataset in the output file with all information
1124 contained (as sequence number, sequence path, data path) so that the
1125 used dataset file can be recreated complete from the output
1126
1127 - sponde: now also allows the uasge of random forest
1128
1129 - sponde: added a plot showing the cut efficiency
1130
1131 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1132 errors (eg. effecting the collection area) because the errors of the
1133 two histograms were swapped in the calculation, which makes a difference
1134 in the case the histograms contains weighted events. Aditionally the
1135 totalarea was incorrectly taken into account, which results in too small
1136 errors, which makes a difference at low statistics were the errors
1137 or the collection area dominate.
1138
1139
1140
1141 *** Version 0.10.3 (2006/10/23)
1142
1143 - database: Implemented ObservationMode flag in websites.
1144
1145 - database: For sequences there is now also the stoptime available on the
1146 websites.
1147
1148 - database: Removed ManuallyChanged flag from sequence-info websites,
1149 as it is not needed anymore with the new sequence building algorithm.
1150
1151 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1152 Class for calculation of confidence intervals (upper limits).
1153 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1154 Please read the class instruction of TRolke for more information.
1155
1156 - general: The programs now return 0xfe if the requested resource file
1157 doesn't exist.
1158
1159 - general: Errors comming from root itself are now not output to
1160 stderr anymore but to our default (colored) log-stream.
1161
1162 - general: Changed the interface to TFormula such that now everything
1163 is parsed by TFormula, which should allow to use phrases even
1164 without paranthesis correctly parsed.
1165
1166 - callisto: replaced the AdHoc number of effective integration slices
1167 in the digital filter by an average of the correct number, averaged
1168 over all possible set of weights. This also gives correct numbers
1169 for the lo-gains which were totally wrong before.
1170
1171 - callisto: drastically reduced memory consumption by not storing
1172 all intermediate calibration results in memory anymore (we might
1173 write them into a file in the future)
1174
1175 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1176 debug plot displayed as a standard plot) use the context menu
1177 somewhere between the two upper plots, click on "DrawNicePlot"
1178 and enjoy the result. (It is the same context menu which contains
1179 the "DrawAll" option)
1180 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1181
1182
1183
1184 *** Version 0.10.2 (2006/10/15)
1185
1186 - general: changed the building of the sequence files such, that
1187 the source-/project name in case of wobble-sources is not the
1188 source/project of the first data run anymore but the new generalized
1189 wobble source/project
1190
1191 - general: Added some functions to MAstro to calculate sun and
1192 moon properties
1193
1194 - general: Added two new macros (starvisday.C and starvisyear.C)
1195 which allow to plot the visibility of several stars in one day
1196 or of one star along one year
1197
1198
1199
1200 *** Version 0.10.1 (2006/10/11)
1201
1202 - general: HTML logging output was distorted... fixed.
1203
1204 - general: Changed the writing of the sequencefiles such that only
1205 as many pedestal files as giving at least 1000 pedestal events which
1206 are nearby the first calibration run are used as pedestal runs
1207
1208 - sponde: In the calculation of the collection area(s) and the
1209 distribution for MOnte Carlo and estimated energy the error
1210 calculation was wrong because root didn't take the errors
1211 properly into account... fixed.
1212
1213
1214
1215 *** Version 0.10 (2006/10/10)
1216
1217 - general: all executables now check consistency of the root version
1218 installed with the root version used for compilation. The return
1219 code in this case is 255.
1220
1221 - general: The algorithm to build seqeunces has been redesigned
1222 completly. It is now more flexible in terms of a resource file
1223 resources/sequences.rc which can be used to partly overwrite
1224 the default algorithm and defined the important part of the
1225 algorithm. It also takes correctly into account several ways
1226 of taking wobble-data. Currently the new algorithm doesn't take
1227 the number of pedestal events anymore into account (so a sequence
1228 could have much less than 1000 pedestal events and data runs are
1229 no-more used instead)
1230
1231 - general: a lot of small changes to make the code compatible with
1232 root 5.12/00 and gcc 4.1
1233
1234 - general: Fixed some warnings thrown if more warnings are switched
1235 on in the compiler
1236
1237 - general: Added a function to MMath which returns the Median of
1238 the distribution abs(y[i]-median) but at 68:32 division instead
1239 of 50:50, which is somehow the median counterpart of the rms.
1240
1241 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1242 even if they are compressed with gzip (recommended compression
1243 is with "-1")
1244
1245 - showplot:
1246 + batch mode creation of image files now works with root 5.12/00
1247 + added support for writing bmp (though it never produces
1248 bmp which can be read by programs like xv or gimp)
1249 + added support for xml
1250 + added new option to start the display with a different size, by
1251 --display-width=nnn or --display-height=nnn
1252 + added options to define the canvas size when the display is started
1253 --canvas-width=nnn or --canvas-height=nnn
1254 the option can also be used for batch-mode conversion
1255 + added an option which automatically fits the display size to the
1256 desktop-size: --auto-size
1257
1258 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1259
1260 - merpp: allow the reports to have 1000ms due to a bug in the camera
1261 program.
1262
1263 - callisto: New swapped pixels have been found and corrected. For
1264 details see MRawRunHeader::FixAssignment()
1265
1266 - callisto: Callisto now raises an error if one of the input files could
1267 not be opened.
1268
1269 - callisto: In some rare cases it could happen that in the signal
1270 extraction of the digital filter the extractor returned nonsense
1271 results due a wrong initializion of a variable (this happens in
1272 cases in which the extracted signal is exactly zero or the
1273 digital filter couldn't slide because of a too small extraction
1274 window, which could happen in the lo-gain extraction)
1275
1276 - callisto: The lo-gains have been marked as valid in some cases
1277 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1278 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1279 smaller than the number of slices (fLoGainWindowSize) needed
1280 by the lo-gain extractor
1281
1282 - callisto: Updated absolute calibration constants (muon calibration)
1283
1284 - callisto: fixed a bug which caused the hi-gain saturation not
1285 to be handled properly in the spline (the position of the
1286 saturation was calculated incorrectly)
1287
1288 - callisto: fixed a bug which gave weird results if hi- _and_
1289 lo-gain could not be extracted properly. In some cases hi-
1290 and lo-gain have not been extracted at all and the random result
1291 got calibrated. In other cases the hi-gain was saturating and the
1292 lo-gain has not been extracted. For this a completly arbitraty
1293 scale factor was applied to the result from extracting the
1294 charge of the saturating hi-gain.
1295
1296 - callisto: improves handling of extracted signal if lo- and/or
1297 hi-gain could not be extracted properly. If no appropriate
1298 calibration of either the signal or the arrival time is possible
1299 the pixel is now markes as unsuitable instead of estimated.
1300
1301 - callisto: Fixed a problem in the spline extraction which gave
1302 weird results if the signal was extracted from the first (and
1303 highest) slice (as a workaround extraction from the first
1304 slice has been forbidden)
1305
1306 - callisto: Fixed a bug regarding the use of the QE which doesn't
1307 effect the result because the default is used anyhow.
1308 (The bug was there since 14/07/2005)
1309
1310 - callisto: Changed the default for fgLoGainStartShift to -2.4
1311
1312 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1313 factors to be always 10 for all pixels as soon as the first
1314 calibration update has happend.
1315
1316 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1317 was off by more than one slice (which gives wrong values for
1318 pixels which have saturated the hi-gain) This was a problem
1319 mainly for timing studies, not so much for the automatic standard
1320 analysis. Also the values for the Spline have been changed slightly:
1321 + Digital Filter from 1.70 to 0.95
1322 + Spline from 1.39 to 1.30
1323 The numbers were sorted out by an extensive test in the
1324 test-database.
1325
1326 - callisto: Removed the tab showing the average calibrated arrival
1327 time. It never gave useful information.
1328
1329 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1330 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1331 and both were extracted because the hi-gain was above the
1332 LoGainSwitch.
1333
1334 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1335 lo-gain pulse position (after application of LoGainOffset, which
1336 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1337 have saturated and both were extracted because the hi-gain was above
1338 the LoGainSwitch.
1339
1340 - callisto: After extensive tests a new threshold level for determination
1341 of the pulse position has been found at 50phe. This is due to the
1342 fact that for lower pulses the arrival time changes its average
1343 behaviour dramatically. It tends to the average of the extraction
1344 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1345
1346 - callisto: Added two more plots to the calibration part. The average
1347 extracted signal and the average extracted arrival time as
1348 extracted by the signal extractor (This can help debugging problems
1349 because it doesn't involve a fit)
1350
1351 - star: changed the fit for the effective on time such that initial
1352 values are calculated automatically now instead of using build
1353 in values. This makes the fit more indepedant of the underlaying
1354 rates. With a test of ~350 sequences in the test database it could
1355 be shown that the new fit gives the same result +/-1sek.
1356 The highest deviation was +5s the lowest -10s. You can now control
1357 the bahaviour with two resource values:
1358 MHEffectiveOnTime.FistBin: 3
1359 MHEffectiveOnTime.NumEvents: 12000
1360 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1361 from the resulting gamma candidates
1362
1363 - star: The Center histogram in MHHillas is now by default displayed
1364 with the colz draw-option
1365
1366 - ganymed: now produces valid error codes if failed
1367
1368 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1369 with the option "hadronness" instead of "area" or "both" if
1370 you want to use both cuts. The hadronness cut includes a fixed
1371 cut in hadronness (index 8) and a fixed cut in size (index 9).
1372
1373 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1374 the M3Long of the anti source to be not properly evaluated
1375 (actually is was evaluated as a unique random number) in case
1376 of optimization with anti-theta cut switched on. This might have
1377 lead to improper, but not necessarily wrong, optimization results.
1378
1379 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1380 how to use random forest
1381
1382 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1383 ganymed_onoff.rc. Seems to be unintentional that they were different.
1384
1385 - sponde: Since the introduction of the possibility to define a
1386 normalization energy instead of using the integral the default
1387 was not using the integral anymore but a normalization energy of
1388 1GeV. It is now the integral again.
1389
1390 - sponde: Fixed a problem in the weighting which did not allow
1391 a MC slope of -1.
1392
1393
1394
1395 *** Version 0.9.6 (2006/05/24)
1396
1397 - general: changed the binning of the azimuthal profile of the camera
1398 such that it is aligned with the 60deg boundaries.
1399
1400 - merpp: better handling of problems with the TH, TD part of the
1401 CC-REPORT for files older than 200507190 and 200412210
1402 respectively
1403
1404 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1405
1406 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1407
1408 - callisto: if an arrival time is extracted outside the fadc range is
1409 was set to the boundary before. Now a random number is assigned
1410 instead to avoid unfortunate coincidences of arrival times just
1411 by this arbitrary value.
1412
1413 - callisto: added a new option to callisto.rc which allows
1414 to set the maximum arrival time difference allowed for the
1415 badpixel algorithm to determin whether a pixels belongs to a shower:
1416 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1417
1418 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1419 to 0.9 as suggested by Stefan due to a recent study on the fraction
1420 of pixels surviving the image cleaning
1421
1422 - callisto: switched off error in case of "pulse is too much to the left"
1423
1424 - callisto: The extraction window is not adapted anymore. This means that
1425 the pulse is extracted from the full range. The draw-back is that the
1426 background (pedestal) will become slightly higher. Switching on/off
1427 the PulsePosCheck in the callisto.rc only effects filling the
1428 histograms.
1429 WARNING: If the pulse is too much to the left data is calibrated!
1430 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1431 in the database to make sure that your data is valid!
1432
1433 - star: Show also the number of stars correlated correctly by the
1434 starguider
1435
1436 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1437 than one off-source region in wobble-mode. To use it add the following to
1438 your ganymed_wobble.rc:
1439 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1440 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1441 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1442 + Cut1.ThetaCut: None
1443 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1444
1445 - ganymed: in the case the latest report is older than a default (currently
1446 one minute) and the current report will be skip the starguider
1447 correction and calibration will be reset. The maximum age can be
1448 setup from ganymed.rc by (minutes):
1449 MPointingDevCalc.MaxAge: 1.5
1450
1451 - ganymed: A first implementation showing all size-bins for the theta-sq
1452 resp. alpha-plots in a single tab automatically
1453
1454
1455
1456 *** Version 0.9.5.1 (2006/05/05)
1457
1458 - general: Added a new option "zdiff" to the Makefile which runs
1459 "cvs diff" as "make diff" would do, but with compression
1460
1461 - general: accelerated MTFillMatrix (used for eample in all training
1462 and optimization macros) by skipping some obsolete calles in the
1463 eventloop the first and second loop could be accelerated by ~20%
1464
1465 - general: Added a missing feature in the MFilterList class which
1466 prevented MFEnergySlope from working correctly in trainenergy.C
1467
1468 - general: Accelerated the random forest training and usage a bit
1469
1470 - merpp: Adapted to new raw data file format version 6
1471
1472 - merpp: fixed a problem with reading the starguider reports
1473 after 6.3.2006
1474
1475 - callisto: At some times six pixels had to be exchanged manually in the
1476 data. If the pixels to be swaped are both not found, an error was raised
1477 and calibration was stopped. Now it is assumed they are intentially not
1478 mapped and the Error has been changed to a Warning.
1479
1480 - star: Added new image cleaning based on the arrival time of the shower.
1481 The new cleaning can be accessed using the parameter "Time" instead of
1482 the the old one (like "Absolute) in the star.rc-file.
1483 Recommended parameters:
1484 + MImgCleanStd.CleanLevel1: 8.2
1485 + MImgCleanStd.CleanLevel2: 5
1486 + MImgCleanStd.CleanRings: 2
1487 + MImgCleanStd.KeepSinglePixels: No
1488
1489 - star: Simplified the calculation of the effective on time. By letting
1490 the fit start in the third bin the result should become more stable.
1491 The fit quality is now ignored for the theta-plot which is not used
1492 in the analysis later. Still better pre-cut which, for example,
1493 remove events triggered by car-light (rate changing on a short
1494 time-scale) are missing.
1495
1496 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1497 for optimization (kWeakSource) which is suggested by the Berlin
1498 people for weak sources.
1499
1500 - macros: plotdb.C:
1501 + if no dataset and no time-interval is given only sequences with
1502 an effective on-time above five minutes are plotted anymore
1503 + added a new tab "RelTime" displaying the relative on-time
1504 (effective on-time divided by the observation time)
1505
1506 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1507 the optimization became a lot faster
1508
1509 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1510 To display them just delete the pads displayed on top.
1511
1512 - ganymed: fixed a bug which could cause strange behaviour in wobble
1513 mode if no starguider information was available due to an incorrect
1514 initialization of the starguider calibration
1515
1516 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1517 be changed from within the plot. It can also be setup from the
1518 resource file using:
1519 + MHDisp.fScaleMin: 0.325
1520 + MHDisp.fScaleMax: 0.475
1521
1522 - ganymed, showplot: Fixed a problem with the fit to the off-data
1523 (HistOff) which could cause a time lag or an inifinite loop.
1524 The bug did not effect the results at all.
1525
1526 - sponde: Added a new tab showing the effective collection area after
1527 trigger (including the software trigger)
1528
1529 - sponde: MMcSpectrumWeight has a new option which allows to define
1530 the scaling factor not by the integral of the events but at
1531 a defined energy:
1532 e.g. MMcSpectrumWeight.NormEnergy: 200
1533
1534 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1535 eventloops the loop could be accelerated by ~20%
1536
1537
1538
1539 *** Version 0.9.5 (2006/03/13)
1540
1541 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1542 and added the standard Disp-parametrization
1543
1544 - macros: added a new macro datacenter/macros/plotstat.C allowing
1545 to plot statistics about the data processing
1546
1547 - macros: added a new macro to plot the muon correction coefficients
1548 versus period (macros/plot/mucal.C)
1549
1550 - showplot: path inflation for ganymed files was broken
1551
1552 - callisto: Fixed an important bug. When the number of saturating pixels
1553 were calculated the bad pixel information already available from the
1554 calibration was ignored. This yields wrong values in case pixels
1555 are broken and saturate all the time or randomly.
1556
1557 - callisto: Updated Muon calibration constants. Spline data now also uses
1558 different values for different periods
1559
1560 - star: The time-evolution shown in the effective on-time plot now displays
1561 the axis range (if there are no holes it should be similar to the
1562 effective on-time)
1563
1564 - star: Added two new image parameters:
1565 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1566 the three pixels next to the center of gravity and the size
1567 + MNewImagePar.fConcCore: The ratio of the signals of all
1568 pixels inside or touching the ellipse and the size
1569
1570 - ganymed: now stops in requested source isn't found in catalog file
1571
1572 - ganymed: Many improvements to the phi-plot in wobble mode:
1573 + with a template the ideal background is displayed
1574 + a possible camera inhomogeneity is taken into account
1575 + the anti theta cut is better supported
1576 + the phi cut is automatically calculated from the theta cut
1577 See the examples in ganymed_wobble.rc for more details.
1578
1579 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1580 times the bin-width instead of the absolute energy
1581
1582 - ganymed: New cuts for on/off and wobble mode
1583
1584 - ganymed: The smearing of the False Source plot has been increased
1585 to 0.06
1586
1587 - ganymed: The starguider calibration can now be changed from the
1588 resource file.
1589 See the examples in ganymed*.rc for more details.
1590
1591 - ganymed: added a new option for on-/off-observations
1592 MJCut.RandomSourcePosition
1593 If switched on the distribution of observation time of the source
1594 position in the camera is calculated from the on-data and randomly
1595 applied with this distrbution to the off-data.
1596
1597 - ganymed: by skipping some obsolete calles in the eventloop the
1598 first and second loop could be accelerated by ~20%
1599
1600 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1601 position in the off-data randomly according to its distribution in the
1602 on-data.
1603
1604
1605
1606 *** Version 0.9.4.3 (2006/02/13)
1607
1608 - general: Fixed a bug in most of the programs which prevented the
1609 compile date in the startup message to be displayed
1610
1611 - general: Simplified program calls. The following abbreviations
1612 are now possible:
1613 showlog callisto 55599
1614 showplot signal 55599
1615 star 55599
1616 callisto 55999
1617 ganymed 2
1618 In this cases the corrsponding root-, log-, sequence- or dataset-
1619 filename is automatically compiled using the default datacenter
1620 paths ("/magic/*")
1621
1622 - general: Fixed a long outstanding bug which made axis tick marks
1623 disappear if MDataFormula was used (eg. abs(x))
1624
1625 - general: Updated MMath with new functions to calculate the results of
1626 a exponential, logarithmic and powerlaw fits analytically.
1627
1628 - general: Updated some macros with comments:
1629 + macros/optim/optimdisp.C
1630 + macros/optim/optimenergy.C
1631 + macros/optim/optimwobble.C:
1632
1633 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1634 files) now allows adding a pre-cut like in the optimization. E.g. this
1635 is useful to perform g/h-separation cuts before training the random
1636 forest.
1637
1638 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1639 correctly assigned in the raw data assignement table. A fix to correct
1640 the assignment tabel have been implemented.
1641
1642 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1643 by 90, 180 and 270 deg.
1644
1645 - general: the macro plotdb.C now allows to highlight sequences belonging
1646 to a datset. For more details see the descritions in the macro.
1647
1648 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1649 of the display, it gave wrong results espacially for big sizes.
1650 Now the embedded canvas should always have a ratio width/height=3/2.
1651 The "Size" options have been updated with values fitting the 3/2
1652 size ratio.
1653
1654 - RanForest:
1655 + Updated the random forest classes to support also the
1656 regression method implemented by Thomas H.
1657 + added new tutorial macro how to train the random forest
1658 for energy estimation (macros/optim/rfenergyest.C)
1659 + new classes to train the random forest (still in development)
1660 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1661 + new tutorial macros for random forest training in macros/train
1662 trainenergy.C, traindisp.C, trainseparation.C
1663
1664 - mars: now allows to setup a cut in the resource file mars.rc to choose
1665 the events to be displayed, eg:
1666 Cut.Condition: {0} && {1}
1667 Cut.0: MHillas.fSize>100
1668 Cut.1: MHillas.fSize<900
1669
1670 - merpp: Made aware of the new .rep format 200510250. This includes
1671 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1672 the discriminator thresholds (MCameraTD) and the disciminator
1673 delays (MCameraTD). All of them come with the CC report and are therefor
1674 written to the CC tree.
1675
1676 - callisto: fixed a bug in the calculation of the arrival times in
1677 the Digital Filter. They were all shifted by the same amount
1678 fHiGainFirst. This caused an offset in the order of the position of
1679 the left border of the extraction window in the times calculated
1680 from high-gain and from low-gain. The bug effected only the absolute
1681 arrival times. The bug was there since 30.1.2005.
1682
1683 - callisto: Changed the ExtractionWindow for the pulse position check
1684 such that the camera inhomogeneity becomes as less as possible and
1685 comparable to the pulso position check switched off. More details
1686 on the study will be given at our result web-page.
1687
1688 - ganymed: ganymed.rc, ganymed_onoff.rc:
1689 changed to new cuts trained with 1ES1218 and Crab-data
1690 for maximum sigma*log10(excess)
1691
1692 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1693 a new option was implemented to estimate Disp (CalcDisp)
1694
1695 - ganymed: Implemented two new options which allow
1696 to overwrite the default path to search for the sequence files
1697 --ins=/magic/sequences
1698 and where to search for the image data
1699 --ind=/magic/data/star
1700
1701 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1702 dx/dy from the resource file by
1703 MSrcPosCorrect.Dx
1704 MSrcPosCorrect.Dy
1705
1706 - ganymed: fixed reading the source catalog. Only as many chars
1707 as the requested source name had were compared (If a source
1708 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1709 were requested it could happen that the coordinates of
1710 "1ES1218" were read) The source coordinates are now printed
1711 in addition to its name to the logging output.
1712
1713 - ganymed: changed the background fit in the case of a ThetaSq function
1714 from a polynomial to a exponential, this should give a big improvement
1715 for on-only analysis'
1716
1717 - ganymed/sponde: Calculation of the error of single size-/energy-
1718 bins now uses Li/Ma (5) instead of LiMa (17)
1719
1720 - sponde: Added a plot E^2*dN/dE
1721
1722 - sponde: The energy estimator plot should now show values like
1723 they are commonly used.
1724
1725 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1726 (a powerlaw with cutoff didn't work before)
1727
1728
1729
1730 *** Version 0.9.4.2 (2005/10/01)
1731
1732 - general: added new tutorial macro macros/tutorials/threshold.C:
1733 how to calculate the threshold
1734
1735 - general: added a new game. Start it from the interpreter with
1736 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1737 and MagicReversi)
1738
1739 - general: neighbor pixels in MGeoms are now sorted clockwise
1740
1741 - merpp: made aware of new format 20050829-0
1742
1743 - callisto: New scale factors from muon analysis, stored in new
1744 resource file resources/calibration.rc
1745
1746 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1747 the eventloop if something went wrong. This is necessary for the
1748 automatic processing
1749
1750 - callisto: Implemented a new treatment for the time information
1751 developed by S.Ruegamer, this should give much better response than
1752 the old very primitive algorithm. This is especially important
1753 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1754 treatment was buggy! As neighbor pixels to interpolate the
1755 arrival times always the pixels 0 to 5 were taken)
1756
1757 - callisto: In addition to the new treatment of arrival times the
1758 decision of the treatment whether a pixel contains shower
1759 information or not is used to improve the signal interpolation
1760 further. Previously interpolated pixels showed a non-zero signal
1761 do the peak searching signal extractors. Having a signal pixel
1762 beside raised the signal above the cleaning level. Thus the
1763 pixel survived cleaning to often but with a too low mean signal.
1764 By replacing empty pixels with a gaus (mean and rms from the
1765 corresponding Area entries in MPedPhotCam) this effect can
1766 be supressed.
1767
1768 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1769 got lost when the events were stored by the calibration... fixed.
1770 (This was no problem for normal image cleaning because the pixel
1771 content was artificially set to 0 not surviving standard cleaning
1772 algorithm)
1773
1774 - callisto: Fixed a bug which caused the random and peak-search pedestal
1775 extracted with an extractor to be exchanged for the first (roughly)
1776 500 events (*Extractor and *ExtractorRndm).
1777 (They were simply exchanged in callisto.cc) This bug might have been
1778 introduced in Mars 0.9.4 when the order of calculation of the two
1779 types of pedestal in callisto got exchanged. The bug only effects
1780 the first seconds of data of each sequence.
1781
1782 - star: Taking the arrival time of Muons into account the calculation
1783 of the parameters could be made independant of the noise
1784 (pedestal rms). The dependance was due to the bias of the peak search
1785 extractor. Now only a ZA dependamcy is left which is not yet fully
1786 understood.
1787
1788 - ganymed: The sequences were still not sorted correctly in any case,
1789 because they were sorted by the full qualified path name. Now they
1790 are sorted by their sequence number.
1791
1792 - ganymed: new values for the spark-event-cut
1793
1794 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1795
1796
1797
1798 *** Version 0.9.4.1 (2005/08/18)
1799
1800 - callisto: fixed some problems with the calibration in case of
1801 inteleaved events. Therefor the final and some intermediate
1802 fits are skipped which would take place on partly filled #
1803 histograms and gave wrong results or failed completely.
1804
1805 - callisto: If the intermediate finalization of the histograms
1806 calculating the mean charge of the calibration signal fails
1807 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1808
1809 - ganymed: Fixed some bugs which caused problems in On-only mode.
1810 Still the false source plot doesn't give reasonable results.
1811
1812
1813
1814 *** Version 0.9.4 (2005/08/05)
1815
1816 - general: Fixed the ZA binning. It did not correctly fit the
1817 MC binning
1818
1819 - general: Added a class to correct for the missfocussing in
1820 April (MSrcPosCorrect)
1821
1822 - general: Random Forest energy estimator should now work properly
1823
1824 - general: MHCamera now displays the profiles in deg instead of mm
1825
1826 - general: MH::SetPalette offers a lot of new palettes
1827
1828 - general: MHillas - the case of CorrXY==0 is now handled properly
1829
1830 - general: implemented the possibility to change the line and
1831 marker style of a sky-grid drawn by MAstroCatalog
1832
1833 - general: Runs in sequences and datasets are now automatically
1834 ordered (it is assumed that the order of their filenames correctly
1835 represents the order of observations) to ensure correct reading
1836 of the subsystem data
1837
1838 - general: Runs cannot be added to a sequence twice anymore. Also
1839 Sequences cannot be added twice anymore to a dataset.
1840
1841 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1842 It gave wrong results by 1./2pi
1843
1844 - showplot: got a new option to start a root interpreter, too
1845
1846 - mars: now displays a rough estimate of Disp and the third moment
1847
1848 - mars: now displays the event time MTime if available
1849
1850 - mars: show muon parameters graphically
1851
1852 - mars: now the file to open can be given as commandline
1853 argument
1854
1855 - merpp: Added support for new arehucas version >= 200507190
1856 implementing values for three temperature sensors in the
1857 counting house (MCameraAUX) and the name of the HV settings file
1858 (MCameraHV).
1859
1860 - merrp: Also fixed some problems with wrong versions numbers stated
1861 by arehucas and implemented some fixed for old versions (<200407070)
1862
1863 - callisto: MCalibrationHiLoCam can now be printed from its context
1864 menu, eg in the TBrowser
1865
1866 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1867 - 1.39 (MExtractTimeAndChargeSpline)
1868 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1869 This is important mainly for timing studies.
1870
1871 - callisto: Changed limits in MHCalibrationChargeCalc from
1872 - -100.125 to -98 (fgChargeHiGainFirst)
1873 - 1899.875 to 1902. (fgChargeHiGainLast)
1874 - -100.25 to -99 (fgChargeLoGainFirst)
1875 - 899.75 to 901. (fgChargeLoGainLast)
1876 Introduced new limits:
1877 - fgNumLoGainBlackoutLimit: 0.05
1878 - fgLoGainBlackoutLimit: 3.5
1879 - fgLoGainPickupLimit: 3.5
1880
1881 - callisto: The handling of automatic weights for the digital filter
1882 has been improved. There are now new calibration weights special
1883 for Monte Carlo calibrations.
1884
1885 - callisto: Updated Muon scale with latest results (1% difference
1886 for most data, 5% for Mar/Apr'05)
1887
1888 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1889 was saturated and the blackout-events in the low-gain exceed the
1890 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1891 This excludes those pixels which have a saturating high-gain
1892 channel, but the low-gain switch does not switch often enough
1893 to make the distribution reliable.
1894
1895 - callisto: fix a bug counting the number of saturated events. Up to now,
1896 the number of saturated slices was counted (which is one for a not too
1897 high number), but for some (pathological) pixels, many more slices
1898 saturated and produced wrong limits.
1899
1900 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1901 + MCalibrationRelTimeCam.CheckFitResults: Yes
1902 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1903 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1904 + MCalibrationRelTimeCam.CheckOscillations: Yes
1905
1906 - callisto: introduce max. number of events for intercalibration,
1907 the rest gets skipped. Default: 4096
1908 The calibration causes too many un-reliable pixels if more
1909 than about 5000 events are treated (@500 Hz) because of the
1910 mode hopping of the VCSels. However, in the past, some
1911 calibration runs have been taken (erroneously) with more
1912 than 5000 events, especially the intensity scans where
1913 a good precision is needed.
1914
1915 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1916 photo-electrons for the spline extractor by 1-2% (correctly).
1917
1918 - callisto: The intercalibration is now done using a full f-factor
1919 method instead of a simple update. This makes things slower but
1920 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1921 changes.
1922
1923 - callisto: MPedestalY3 now uses the same extraction range as the data
1924 as calculated by MPedestalY2
1925
1926 - callisto: A check of the fraction of allowed unsuitable (10%) and
1927 unreliable (30%) pixels has been addded when the conversion is
1928 calculated from interleaved events
1929
1930 - star: fixed a bug which caused MEffectiveOnTime containers not to
1931 be written. In the worst case they were skipped almost all, in the
1932 best case they were all ok. It depends on how often the new value
1933 was assigned just with an event which was skipped later by another
1934 task
1935
1936 - star: new histograms MHPointing and MHRate
1937
1938 - star: New tab (Currents) displaying the time evolution of the mean
1939 DC currents
1940
1941 - star: New tab (MeanRms) displaying the time volution of the mean
1942 Pedestal Rms
1943
1944 - star: Output now contains MReportStarguider
1945
1946 - star: Improved muon analysis. Due to the absense of a constant
1947 for the gaus fit for arc width and the fact that the arcwidth
1948 plot was a histogram instead of a profile the resulting psf
1949 became pedestal rms dependant
1950
1951 - ganymed: added new plot (MHPhi) for wobble mode as described in
1952 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1953
1954 - ganymed: corrects now (correctly?) for the misspointing in
1955 May/April 05
1956
1957 - ganymed: Two new default templates for ganymed.rc are avilable:
1958 ganymed_onoff.rc and ganymed_wobble.rc
1959
1960 - ganymed: The first version of MFMagicCuts has been released
1961
1962 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
1963
1964 - ganymed, sponde: There are two new options to determin the number
1965 of bins for the signal region (NumBinsSignal) and the number of
1966 total bins (NumBinsTotal) in the MHThetaSq histogram
1967
1968 - ganymed: optimized palettes for MHDisp
1969
1970 - ganymed: Fixed an important bug when using ThetaSq as fit function:
1971 The result for the sigma of the gauss(sqrt(x)) fit was a factor
1972 sqrt(2) to large
1973
1974 - ganymed: The false source plot (MHDisp) is now based on Disp
1975 and a background model determined in the first loop is
1976 subtracted
1977
1978 - ganymed: MFMagicCuts are now available in the cvs. The correct
1979 solution for the disp ambiguity problem is now calculated using
1980 the third moment. The third moment cut therefor is skipped.
1981
1982 - ganymed: Output now contains "Disp [MParameterD]" which sign is
1983 already determined by the third moment along the major axis and
1984 so its actual sign is aligned along the major axis of the shower.
1985
1986 - ganymed: If starguider data is available it is taken into account
1987 when calculating the source position. This is especially important
1988 for wobble data at high zenith angles and culmination data.
1989
1990 - ganymed: If available the starguider data is taken into account as
1991 good as it is possible without a starguider calibration. To switch
1992 it off add
1993 MPointingDevCalc.MaxAbsDev: -1
1994 to your ganymed.rc
1995
1996 - sponde: the zenith angle distribution is now weighted instead of
1997 choosen by default. This gurantees higher statistics in the highest
1998 and lowest energy bins. To switch this behaviour off use...
1999
2000 - sponde: now automatically displays the energy threshold
2001
2002
2003
2004 *** Version 0.9.3 (2005/06/03)
2005
2006 - general: MMcEvt now derived from MMcEvtBasic which should
2007 have no influence on compatibility with older camera files
2008
2009 - general: Implemented a new option to MReadReports which allows
2010 to force reading of the first event of some trees (eg. Drive-tree)
2011 before any other tree.
2012
2013 - general: Made a fix to MPointingPosCalc which assumes that the
2014 run-type is real-data if Process is called before ReInit, such
2015 that also the very first Drive-events in a run are treated
2016 correctly.
2017
2018 - shoplot now displays the filename in the title bar of the window
2019
2020 - merpp: new options: --auto-time-start --auto-time-stop which
2021 allow to cut updating with slow-control at the start- or
2022 (previousle --auto-time only allowed: and) stop-time of
2023 the run stored in the runheader.
2024
2025 - callisto: changed default of fgFallTimeHiGain in
2026 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2027 already set as default in callisto_Dec04Jan05.rc
2028
2029 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2030 now changes the filename for new weights automatically for
2031 cosmics, MC and for different calibration colors.
2032
2033 - callisto: a problem with the order of some code cause the
2034 name of the weights file in MPedestalY2 to be ignored.
2035 Wrongly the calibration_UV weights were used instead
2036 of the cosmics weights set in callisto.rc.
2037
2038 - callisto: should allow ct1 pulser data when the color is
2039 explicitly set also for pretty new runs
2040
2041 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2042 to introduce an additional scale factor (should be around 1)
2043 to adapt for slight deviations in different extractors from
2044 the MC calibration. For MC calibrations the scale factor
2045 is fixed to 1
2046
2047 - callisto: MFCosmics should handle very high signals a bit
2048 more accurate now
2049
2050 - callisto: when calculating the mean pedestal rms for different
2051 pixel sizes or sectors also kUnsuitableEvt is now taken into
2052 account - not only kUnsuitableRun
2053
2054 - callisto: '-raw' option is now the default
2055
2056 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2057 This has the advantage that mean values in the calibration (eg
2058 arrival times) are calculated more accuratly.
2059
2060 - callisto: In the resource file callisto_Dec04Jan05.rc
2061 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2062
2063 - callisto: new Hi-/Lo-Gain intercalibration constants
2064 hilocalib_sp1.root and hilocalib_sp1_mc.root
2065
2066 - callisto: changed default for MJPedestalY2.MaxEvents
2067 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2068
2069 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2070 has changed from 9.0 to 6.0. This is necessary to exclude two very
2071 ringing pixels in September which - when kept - destroy the image
2072 cleaning around them (Markus G.)
2073
2074 - callisto: (!) The Muon analysis of all data taken so far has
2075 suggested that different extractors give slightly different
2076 absolute results after calibration, due to there different
2077 handling of the calibration- and cosmics pulse shape. Although
2078 the over all calibration seems to be a bit to pesimistic (or
2079 the MC seems to be a little bit - 3-5% - too much attenuated).
2080 There for correction factors have been introduced which correct
2081 the calibration constants by
2082 0.956937799 for Digital Filter (callisto.rc)
2083 and
2084 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2085 calibration. The main advantage is, that both data types can
2086 be easily analysed together and compared to the same MC sample.
2087 The factors are choosen such, that the reference is now a
2088 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2089
2090 - star: fixed a bug which caused the first bin of the histograms
2091 vs time to disapear in PostProcess. This gave wrong results
2092 on the screen. The output and all following programs not
2093 directly accessing the histograms haven't been affected
2094
2095 - star, ganymed: Made sure that always the first Drive-tree event
2096 is read and Processed before the first data event was read.
2097
2098 - ganymed: implemented the possibility to replace the standard
2099 false source plot with a different one. For example: If
2100 you want to use a Disp based FS plot use the resource:
2101 NameHistFS: MHDisp
2102 For details about the requirements of these plots look
2103 at the corresponding classes
2104
2105 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2106 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2107 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2108 case MAlphaFitter is setup correctly. For On-Only optimization
2109 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2110 RunOn() instead of Run(). For energy estimation MJOptimize
2111 has been replaced by MJOptimizeEnergy
2112
2113 - sponde: The input MC spectrum can now be weighted to fake a
2114 different spectrum. This is done via MMcSpectrumWeight. For
2115 more details see the class description and sponde.rc
2116
2117 - sponde: The paremeter comparsion plots are not scaled by
2118 their entries anymore. Instead the MC plot is scaled by using
2119 the result spectrum of the analysis. If the input MC spectrum
2120 and the result spectrum has different slopes the absolut
2121 normalization is normally wrong.
2122
2123
2124
2125 *** Version 0.9.2 (2005/05/20)
2126
2127 - general: Changed the default paths for calibrated data and image
2128 files. (The implemented access to these files doesn't yet exist)
2129
2130 - general: support for MRunIter has been removed from the job classes
2131 (use the setter functions of MSeqeunce instead)
2132
2133 - general: ProcessFile has been renamed to Process in all job classes,
2134 because ProcessFile is missleading
2135
2136 - general: The storage of the palette in MHCamera is now possible
2137
2138 - general: new bits describing unsuitable and unreliable pixels have
2139 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2140 kDeadPedestalRms, kFluctuatingArrivalTimes
2141
2142 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2143 versions newer than V200404070
2144
2145 - general: support for cc file versions newer than V200504130. Added
2146 support for active loads (MCameraActiveLoad) and central pixel
2147 (MCameraCentralPixel)
2148
2149 - general: added new histograms for image parameters versus size
2150 (MHVsSize)
2151
2152 - general: The eventloop now automatically calls PrintStatistics
2153
2154 - Status Display: Improved support for printing:
2155 + A default can now be set in .rootrc (for more details see
2156 MStatusDisplay::PrintPS)
2157 + A print dialog is opened so that printer and command line
2158 can be canged
2159
2160 - showlog: improved such that it handles different verbosity levels
2161 more accurate now. This mean you can suppress output when
2162 using showlog.
2163
2164 - showplot: improved
2165 + The new graphics formats have been implemented
2166 (pdf, svg, png, jpg and xpm)
2167 + Implemented an interface for printing. Because you can change
2168 the printing command from the command line you can use all
2169 the nice postscript tool. To print a booklet for example call:
2170 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2171 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2172 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2173
2174 - callisto: fixed a bug in the recognition of the calibration bit
2175 pattern. Concerns only intensity calibration. (The strength of the
2176 intensity has been updated in some cases)
2177
2178 - callisto: add a filter against PIN Diode events when running over
2179 calibration runs since some of the recent calibration runs have
2180 been taken with Pin Diode.
2181
2182 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2183 39943, 44833 in the calibration (MCalibColorSet)
2184
2185 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2186 been set to 1e-18 in callisto_Dec04_Jan05.rc
2187
2188 - callisto: in callisto_Dec04Jan05.rc: set value for
2189 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2190 statistics for the calculation of the mean pulse time
2191 of the cosmisc
2192
2193 - callisto: the charge limit in the calibration has been raised
2194 from 2.5 to 4.5
2195
2196 - callisto: new setup read from callisto.rc
2197 + MCalibCalcFromPast.fNumEventsDump
2198 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2199 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2200
2201 - callisto: MExtractTimeAndChargeSpline extractor:
2202 + The integration ranges were shifted by 0.2 FADC slices to the right.
2203 + unreliable handling of floating point values caused different
2204 results on different platform or with different compiler options:
2205 The new algorithm is numerically exact and more accurate because
2206 it doesn't calculate the integration position by multiple times
2207 adding the step-size (which results in numerical uncertanties
2208 exspecially if multiplied with large numbers)
2209 + A lot of fixes have been introduced which effects integrating the
2210 spline at the edges of the valid range. In this case any memory
2211 was randomly accessed. This behaviour can be tested replacing
2212 all MArrayF by TArrayF which perform a range check (but of course
2213 they are a lot slower)
2214 ! No result obtained with the Spline before can be trusted! Due to
2215 random memory access it might by completely random!
2216
2217 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2218 + extraction range in the high gain to 4.
2219 + weights file to cosmics_weights46.dat
2220
2221 - callisto:
2222 + introduce the check for fluctuating arrival times.
2223 + set charge limit to from 2.5 to 4.5
2224 + introduce asymmetric exclusion due to "deviating number of phes":
2225 Default: -9.0 +4.5
2226 + make deviating number of phes unsuitable (see David's findings).
2227
2228 - callisto: fixed the display of unsuitable pixels. The old change
2229 to a real profile in MHCamera broke it.
2230
2231 - callisto: The cosmics filter is used in MJCalibration now
2232 independant of the pulser color (formaly it was used only for
2233 CT1-pulser data). The threshold of number of max empty pixels
2234 has been raised from 2% to 5% in MJCalibration. The maximum
2235 fraction of rejected event is 50% otherwise the calibration has
2236 failed. The filter now ignores unsuitable pixels.
2237 Setup the filter from callisto.rc using "ContCosmics"
2238 (see MFCosmics::ReadEnv)
2239
2240 - callisto: changed default for fgOffsetFromLogain back
2241 from -2.8 to -1.8 in digital filter.
2242
2243 - callisto: for the common extractors
2244 + MExtractFixedWindow
2245 * MExtractTimeAndChargeSlidingWindow
2246 * MExtractTimeAndChargeSpline
2247 * MExtractTimeAndChargeDigitalFilter
2248 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2249 and fResolutionPerPheLoGain
2250
2251 - callisto: Updated the hi-/lo-gain intercalibration constants
2252 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2253 hilocalib_df6.root
2254
2255 - callisto: The default lo-gain extraction window for the
2256 MExtractTimeAndChargeSlidingWindow extractor has been increased
2257 from 6 to 8 to take the stretch of the pusle into account
2258
2259 - callisto (!!!): fixed an important bug in the setting of the
2260 incoming pedestal pointer to the signal extractor extracting
2261 pedestals. This bug caused the pedestals not to be subtracted
2262 correctly in the calibration afterwards. The effect was about 10%
2263 too high conversion factors for the digital filter and the spline
2264 and more than 40% for the sliding window.
2265 The bug existed since end of February! (Markus G.)
2266
2267 - star: added muon support to star. A new tab "MHMuonPar" is
2268 displayed. The lower right plot is an estimate of the point spread
2269 function. A reference value is displayed. To get the real PSF
2270 you must compare with MC. The setup for the muon analysis
2271 is done in star.rc. More informations can be found in
2272 MHSingleMuon and MHCalibParCalc
2273
2274 - star: The weather data is now displayed in star
2275
2276 - star: MEventRateCalc handles the calculation of the event rate more
2277 accurate now in case of the start of a new run inside a sequence
2278
2279 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2280 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2281 changed only minimally
2282
2283 - ganymed: (MJCut and MJOptimize) now displayes the number of
2284 excess events versus size. The energy estimation is done in
2285 MJSpectrum (sponde)
2286
2287 - ganymed: got support for using other variables than Alpha, eg. Theta.
2288 Therefor you need a class deriving from MHAlpha which supports
2289 this variable (one is already existing: MHTheta, which is now the
2290 default in ganymed). It is setup through ganymed.rc
2291
2292 - added a full featured spectrum program (sponde) which reads
2293 ganymed output and monte carlos and compiles a spectrum
2294
2295
2296
2297 *** Version 0.9.1 (2005/04/14)
2298
2299 - Fix bug on the arrival time reconstruction when using Digital
2300 Filter (in some marginal cases (10%) times were reconstructed shifted
2301 by 0.2 slices)
2302
2303 - all executables now return 2 where in previous versions -1 has
2304 been returned (gave problems with shell-scripts)
2305
2306 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2307 also done with a intercalibration input file
2308
2309 - a bug in the time fine adjustment of the digital filter has been fixed
2310
2311 - a lot of small fixes to calling TPad::Divide with a margin==0
2312
2313 - MStatusDisplay now shows the memory usage
2314
2315 - added a memory leak statistic after the eventloop
2316
2317 - MHadronness replaced by MParameterD
2318
2319 - MEnergyEst replaced by MParameterD
2320
2321 - wobble mode can now be switched on from the data-set
2322
2323 - switched on bad pixel detection for a pedestal level
2324 which is more than 5 times the variance
2325
2326 - Fixed default paths to be correct for the new data center
2327
2328 - Fixed handling of drive data. The pointing position in now
2329 copied to MPointingPos inside star for real and MC events
2330
2331 - made sure, that the sequences in a dataset are sorted by
2332 their number to ensure the correct synchronization
2333
2334 - added all resource files necessary to handle spline extraction
2335 of signal for the late 2004 and the early 2005 data
2336
2337 - update the reference lines for the december data
2338
2339 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2340 This is important for the Dec. and Jan. data where the calibration
2341 pulse position changes much.
2342
2343 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2344 filter. This corrects only an defective extraction of the MC at
2345 low-gain signals lower than 90 phes.
2346
2347 - fixed some slowdown in calibrating data with interleaved events from
2348 Jan and Dec. As a workaround made the pretty palette the default.
2349 The inverse Deep Blue Sea has a bug which slows down long calibration
2350 runs a lot.
2351
2352 - implemented new values from new starguider report as defined
2353 in TDAS00-07 V7.1 (eg SkyBrighness)
2354
2355 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2356 in starguider report (If you merpp the same reports with this version
2357 you'll get the correct units (arcmin) but a different result
2358 than with old versions (wrong units))
2359
2360 - Now the status display can also write PNG, JPEG and XPM (other file
2361 formats are still unsupported by root)
2362
2363 - added a lot of scripts and macros in directory datacenter used
2364 for automatic processing
2365
2366
2367
2368 *** Version 0.9 (2005/03/23)
2369
2370 - Calibration is now done autmatically into photo-electrons like
2371 decided by the Collaboration Board
2372
2373 - Reference lines in the display can be read from resource file
2374
2375 - Interlaced calibration events can be handled by callisto
2376
2377 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2378 and applied in callisto.
2379
2380 - class MJCalibTest can be called by callisto
2381
2382 - callisto can now run with three data types: rawdata, rootdata, MC
2383
2384 - added two classes mreport/MReportStarguider.cc and
2385 mreport/MReportStarguider.h for implementing starguider-data
2386
2387 - the output of merpp-update now contains starguider information:
2388 MReportStarguider and MTimeStarguider
2389
2390 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2391 values were lower than they should. This was more visible for high
2392 energy (Size) events.
2393
2394 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2395
2396 - added a new loop to callisto to support the correct extraction of
2397 the pedestal and pedestal rms through the signal extractor
2398
2399 - added class to perform fourier tranformation of a hexagonal structure
2400 (MHexagonalFT)
2401
2402 - added class to perform fourier tranformation of a hexagonal structure
2403 in a tasklist (MHexagonalFTCalc) example: hft.C
2404
2405 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2406 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2407 small pixels, example: extendcam.C
2408
2409 - added possibility to write data to memory (TTree) using MWriteRootFile
2410
2411 - added possibility to read a TTree stored only in memory by MReadTree
2412
2413 - new classes to deal with the interleaved calibration events:
2414 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2415
2416 - implemented filters to callisto to skip calibration events
2417
2418 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2419 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2420 the slices by statistics
2421 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2422 signal extractor without randomization
2423 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2424 with the signal extractor with randomization (extraction window is
2425 randomly fixed)
2426 The three kind of pedestal is not yet implemented (for speed reasons) as
2427 long as nobody really needs it:
2428 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2429 extracted with the signal extractor with randomization
2430
2431 - callisto now finds the pulse position in the data automatically
2432
2433 - implemented data reduction in calibrated data by reducing the precision
2434 of the stored floating point values (pedestal, rms and signal) to
2435 roughly 0.5%
2436
2437 - fixed showplot to make file format conversion (eg. converting a
2438 status display stored in a root file into a postscript file) in
2439 batch mode possible:
2440 showplot -b --save-as-ps[=outfile.ps] infile.root
2441
2442 - Allow class names as part of filter rules, eg
2443 (MFSupercuts) && (MHillas.fSize>100)
2444
2445 - fixed a lot of stuff to allow all programs to process MonteCarlo
2446 camera files.
2447
2448 - enhanced possibility to debug reading of resource file
2449
2450 - MDataChain should handle priorities of operator more
2451 accurate now
2452
2453 - completely revised the container in which the signal is stored
2454 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2455 * the new implementation is faster and
2456 * needs less storage space
2457
2458 - FIRST version which can process Monte Carlos through the
2459 whole chain of programs (callisto, star, etc)
2460
2461 - implemented new image parameters for the border length of
2462 the shower image (MNewImagePar2)
2463
2464 - implemented wobble-mode in ganymed
2465
2466 - new class (MJOptimize) taking care of all optimization processes
2467
2468
2469
2470 *** Version 0.8.6 (2004/10/05)
2471
2472 - New combined signal and time extractor
2473 MExtractTimeAndChargeDigitalFilter
2474
2475 - The Report for the trigger section in the CC run summary has been
2476 updated, and now the IPRs (Individual Pixel Rates) are available.
2477
2478 - new macros for database interaction: filldotrun.C, filldotrbk.C
2479
2480 - added new program which can convert colored output which was redirected
2481 into a file back into colored text (for example to display it with
2482 more): showlog
2483
2484 - added new program to display an MStatusArray of plots (stored with
2485 MStatusDisplay) from a file: showplot
2486
2487 - Added support for Sequences (MSequence). Sequences are blocks of run
2488 files containing the same calibration and belonging to the same
2489 source
2490
2491 - Added a new task (MTaskEnv) which can be used in setup files to switch
2492 between different tasks (for example to choose a signal extractor)
2493
2494 - Implemented automatic file splitting in MWriteRootFile
2495
2496 - After image cleaning an island index is assigned to all used pixels.
2497 The index corresponds to the order of the islands in size.
2498
2499 - added a cleaning which takes signal height _and_ arrival time into
2500 account: probability cleaning (for more details see MImgCleanStd)
2501
2502 - added a cleaning which takes takes the absolute number of photons
2503 times the area ratio as cleaning level
2504 (for more details see MImgCleanStd)
2505
2506 - Changed calculation of image parameters such, that it can be done
2507 for all used pixels or the pixels with a defined island index only
2508
2509 - implemented new image parameters displaying the number of islands,
2510 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2511
2512 - event display in executable changed to support also calibrated files
2513 (done with MJCalibrateSignal)
2514
2515 - added program doing the calibration and the signal extraction
2516 and signal calibration: callisto Most part of the setup is done
2517 by a resource file: callisto.rc
2518
2519 - implemented support for pixels with negative IDs (Raw file format
2520 version 4)
2521
2522 - implemented an new option in merpp (--auto-time) to get the time
2523 range for cc and/or caco data from the run header of the raw data
2524
2525 - New star-program (star and MJStar). Taking calibrated data from
2526 callisto/MJCalibrateSignal as input. The setup is done through
2527 a resource file: star.rc
2528
2529 - Added possibility to setup the eventloop in the mars-executable
2530 Camera Display by a resource file: mars.rc
2531
2532 - The the mars-executable Camera Display can now also read
2533 calibrated data files written by callisto/MJCalibrateSignal
2534
2535 - Added a new class which can calculate the source position in
2536 the camera from a pointing model known to be correct and
2537 the pointing model used for observations (MSrcPosFromModel)
2538
2539 - added a new version of the class calculating the effective on-time
2540 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2541 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2542 MHTimeDiffTheta.
2543
2544 - added the possibility to count how often a signal is above (or
2545 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2546 can replace MHTriggerLvl0)
2547
2548 - added ore convinient ways to set the axis-titles of your histograms
2549 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2550 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2551
2552
2553
2554 *** Version 0.8.5 (2004/08/06)
2555
2556 - new Signal Extractors: MExtractFixedWindowSpline
2557 and MExtractAmplitudeSpline
2558
2559 - implementes interleave in merpp to be able to merpp parts of a file
2560
2561 - implemented force-functionality to merpp
2562
2563 - star display to display star catalogs (MAstroCatalog)
2564
2565 - star display to 'mirror' stars to the camera (MAstroCamera)
2566
2567 - implemented a new cleaning option which allows cleaning scaled with
2568 the real ratio of the rms depending on the pixel size, not only the
2569 square root of the pixelsize (MImgCleanStd, MCameraData)
2570
2571 - removed obsolete MBlind* classes
2572
2573 - Signal extractor taking the AB flag into account implemented (this makes
2574 an odd number of slices for signal extraction possible
2575 (MExtractSignalABcorr)
2576
2577 - implemented a class extracting the pedestal from the raw-data (events)
2578 itself using empty lo-gain (MpedCalcFromLoGain)
2579
2580 - Added mean values to MPedPhotCam
2581
2582 - Added Makefile for Darwin (this OS is NOT officially supported!)
2583
2584
2585
2586 *** Version 0.8.4 (2004/04/19)
2587
2588 - new fast arrival time extractor using cubic splines:
2589 MExtractTimeFastSpline
2590
2591 - implementes multi-argument support in MDataChain
2592 ("pow(a, b)")
2593
2594 - implemented double reference support in MDataChain
2595 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2596
2597 - added support in MF for expressiond like
2598 "MHillas.fWidth<2*<MHillas.fLength"
2599
2600 - MDataChain is now able to support variables like [0], [1], ...
2601 which can be used in fit functions as parameters. The interface
2602 is implemented through the new virtual function
2603 MParContainer::SetVariables
2604
2605 - added new class MArrivalTimeCam/MArrivalTimePix:
2606 Storage containers to hold the ArrivalTime of the camera/pixel
2607
2608 - added new classes for the calibration of relative arrival times:
2609 MCalibrationRelTimePix and MCalibrationRelTimeCam
2610
2611 - added new classes to extract the signal of the blind pixel and the
2612 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2613
2614 - added new classes for the bad-pixels treatment (MBadPixels*)
2615 which are more powerfull than the old ones (MBlindPixel*)
2616 and will replace them.
2617
2618 - added filter against cosmics: MFCosmics
2619
2620 - added new class MArrivalTimeCalc2:
2621 Calculates the arrival time as the signal weighted mean of the time
2622 slices in the maximum window
2623
2624 - added a new macro call pointspreadfucntion.C that fits with a 2D
2625 gaussian the DC spot for an star. It gives you the RMS of
2626 the PSF and the center of the star, very useful for misspointing
2627 studies.
2628
2629 - added support for multi-telescope camera files. Added classes
2630 MStereoCalc and MStereoPar, classes to calculate and store shower
2631 parameters calculated from the data of two telescopes, for the MC
2632 studies regarding the MAGIC clone.
2633
2634 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2635 MC data calibrated in photons instead of ADC counts.
2636
2637 - added three macros to show the calibration and analysis chain of
2638 MC data. The macro starmc.C does both calibration and analysis, producing
2639 an output containing Hillas parameters for each event. The macro
2640 mccalibrate.C does just the calibration and writes out a file containing
2641 pixel information in photons instead of FADC data. The macro starmc2.C
2642 reads in such a file and produces an output with Hillas parameters.
2643
2644 - added MPedPhotCalc to compute pedestals in units of photons, see
2645 macro pedphotcalc.C
2646
2647 - added all class to perform the calibration, see macro calibration.C
2648
2649 - added class MFFT to perform Fast Fourier Transforms
2650
2651 - added class MSimulatedAnnealing to perform simulated annealing
2652 minimizations
2653
2654 - added new macro bootcampstandardanalysis.C which holds the skeleton
2655 of the analysis chain discussed in the december bootcamp.
2656
2657 - added support for DAQ raw data file format V2
2658
2659 - implemented an arbitrary time stamp for the events from raw-data
2660 files with file version<3. It is calculated from the run number,
2661 the date of start and the FADC clock tick from the first module
2662
2663 - implemented the correct decoding of the event time-stamp
2664 coming from the DAQ for raw-data files with file-version>2
2665
2666 - added a new classes storing the pedestals in units of photons:
2667 MPedPhotPix, MPedPhotCam
2668
2669 - added support for DC current files from the camera control
2670
2671 - added support for start- and stop-time when merpping report files
2672
2673 - added MReportCC storing the weather data from the CC-REPORT
2674
2675 - added class to fill trainings and test matrices (MTFillMatrix)
2676
2677 - added a filter performing a software trigger (MFSoftwareTrigger)
2678
2679 - Added classes to perform parts of the standard analysis (Jobs):
2680 + MJPedestals
2681 + MJCalibration
2682 + MJExtractSignal
2683 Note: All of them are preliminary!
2684
2685 - Added Iterator to iterate over files giving only the run-number
2686
2687 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2688 the evolution of a sector vs time
2689
2690
2691
2692 *** Version 0.8.3 (2003/12/05)
2693
2694 - adapted Random Forest classes to allow the use with MC
2695 multi-telescope files which can be produced with the coming
2696 camera version 0.7.
2697
2698 - added classes to read and interprete central control report files
2699 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2700
2701 - enhanced merpp (the executable) to support .raw and .rep files.
2702
2703 - added classes for light calibration (MCalibration* and
2704 MHCalibration*) by Markus Gaug. Further work has to be and will
2705 be done soon.
2706
2707 - Added a preliminary 'synchronizer' (MReadReports) which will
2708 replace MReadMarsFile as soon as it is finished.
2709
2710 - Added a tutorial macro demonstrating how report files are merpped
2711 and how they can be read from the root file in the correct order
2712 of time (readrep.C)
2713
2714 - Added a generalized histogram (similar to MH3) called MVsTime
2715 which allows to plot variables (or rules - MDataChain - of
2716 variables) vs time. For an example have a look at tempvstime.C.
2717
2718 - Changed the name of the event trees:
2719 + Events --> Events
2720 + PedEvents --> Pedestals
2721 + CalEvents --> Calibration
2722
2723 - changed name of MTime in the event trees from MRawEvtTime to MTime
2724
2725 - added displaying the sector indices to the mars event display
2726
2727 - Magic Online Analysis (MOnA) implemented in a first version
2728 (see mona.cc, MOnlineDump and MOnlineDisplay)
2729
2730 - added classes to calculate event rate
2731 (preliminary: MEventRateCalc, MEventRate)
2732
2733 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2734
2735 - added classes dealing with the telescope pointing position (MPointing*)
2736
2737 - implemented the 'final' Mars time stamp based on some experiences with
2738 the new 'Synchonizer'
2739
2740
2741
2742 *** Version 0.8.2 (2003/11/10)
2743
2744 - accelerated standard analysis by a factor of 6-8 ...
2745 + doing precalculations in MGeomCam for the pixel area ratio
2746 + creating a look up table for the single pixels in MCerPhotEvt
2747
2748 - added task to calculates weights in case you want to 'change'
2749 the energy spectrum of a monte carlo file
2750 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2751
2752 - added a new executable star which implements the
2753 star.C macro as precompiled executable. Currently a flexible
2754 setup is not possible, but a 'input card' setup will follow.
2755
2756 - Starting to implement Multi-Telescope-Support based on the
2757 upcomming camera version 0.7. The base for a general support
2758 is implemented and the star-functionality is proven to work.
2759
2760 - Replaced Event-Display in and Camera-Display in the Mars GUI
2761 executable by a more convinient display base on MStatusDisplay.
2762
2763 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2764
2765
2766
2767 *** Version 0.8.1 (2003/10/20)
2768
2769 - added signal subtraction for pure on data by means of fitting
2770 the background in the off region or by performing a combined
2771 signal/background fit. Provides necessary histograms for
2772 obtaining energy spectra and a light curve.
2773
2774 - added classes to perform and study the selection of the
2775 2nd Level Trigger on MC data (example in triglvl2.C macro)
2776
2777 - added pedestal calculation
2778
2779 - implemented "democratic cleaning" (tail cut value proportional
2780 to pixel area) according to Wolfgang's suggestion.
2781
2782 - added Sigmabar treatment (calculation and basic histogramming)
2783
2784 - added basic routines to apply padding
2785
2786 - added first implementation of MARS-based source visibility plotter
2787 (needs to be linked against slalib, preliminary version)
2788
2789 - enhanced functionality of data chains: random numbers, conversion
2790 functions and access to MHMatrix objects
2791
2792 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2793 numbers under certain circumstances (runs with 0 events included)
2794
2795 - fixed a bug in the general filter MF (didn't work on some systems
2796 at all)
2797
2798 - fixed a bug in chaining files, which caused the analysis to crash or
2799 ignore files
2800
2801 - implemented more geometry classes describing the parameters used
2802 to simulate the PMT camera
2803
2804 - added new Monte Carlo classes containing the setup of the different
2805 programs in the MC chain.
2806
2807 - added a (preliminary) general task to evaluate chi-square of a given
2808 parameter in an eventloop.
2809
2810 - first implementation of a container describing the observatory
2811 location (Long, Lat, etc)
2812
2813 - added Random Forest - method for g/h-separation
2814
2815 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2816 (this means, that it is compiling, but not yet fully tested)
2817
2818 - added a new status display which can show the present status
2819 of histograms while an eventloop is running (MStatusDisplay,
2820 an example can be found at status.C)
2821
2822 - reorganized directories:
2823 classes describing the image --> mimage
2824 classes containing Monte Carlo Histograms --> mhistmc
2825 classes for Random Forest method --> mranforest
2826
2827 - added (event-)weights to fill histograms
2828
2829 - colors in logging output to screen
2830
2831 - changes to the Image Parameter declaration:
2832 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2833 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2834 + MHillasExt now derives from MParContainer instead of MHillas
2835 --> Files written with the old definition are more or less unreadable
2836
2837 - reading of reflector files
2838
2839 - display data from reflector files in the camera
2840
2841 - implemented currents (and display them in the camera)
2842
2843 - logarithmic scale in camera
2844
2845 - added class to iterate through directory contents (MDirIter)
2846
2847
2848
2849 *** Version 0.8 (2002/11/18)
2850
2851 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2852
2853 - corrected 48(!) wrong entries in the Next Neighbor table of the
2854 Magic Camera (all in the inner part of the outer ring, mostly
2855 missing a single NN)
2856
2857 - Fixed a bug in the table describing the Next Neighbours of the
2858 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2859 have any neighbour)
2860
2861 - changed trigrate.C: now it calculates the pure NSB triggers from
2862 a camera file (generated with no showers), so there is no need
2863 to introduce them by hand in the BgR array (for more details
2864 please ask Abelardo)
2865
2866 - added MHHadronness (and MHadronness) as a general facility to evaluate
2867 the quality of a gamma-hadron seperation method
2868
2869 - changed MWriteAsciiFile to accept rules (MDataChain)
2870
2871 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2872 must be replaced by calles to MWriteAsciiFile::AddColumn and
2873 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2874 changed.
2875
2876 - Implemented generalized event-matrices (one row per event)
2877 (MHMatrix)
2878
2879 - implemented the one dimensional composite probabilities
2880 (MHCompProb, MCompProbCalc, comprob.C)
2881
2882 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2883 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2884
2885 - Added a camera display displaying the pixel numbers to the
2886 event display gui.
2887
2888 - Added Monte Carlo Informations to event display gui
2889
2890 - Changed the camera display to display the pixel numbering
2891
2892 - Added three buttons to the camera display to change the palette
2893
2894 - Added the number of used and core pixels after image cleaning
2895 to MHillas
2896
2897 - Changed the algorithm used in MHillas according to TDAS 02-03
2898
2899 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2900
2901 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2902
2903 - Added fCosDeltaAlpha to MHillasSrc
2904
2905 - The numbers of photons used to calculate fConc and fConc1 in
2906 MHillasExt are now scaled with the pixel size, so that one get
2907 a four times smaller value for the bigger pixels in the outer ring.
2908
2909 - added new task to smooth the camera contents (MCameraSmooth)
2910
2911 - added possibility to use interpolated pixel values for blind pixels
2912 instead of removing it completely from the analysis
2913
2914 - Implemented the possibility to save the whole eventloop with
2915 its setup to a file. This information can be read and from
2916 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2917 and MEvtLoop::MakeMacro. If you find something not working, please
2918 report - this stuff is still in a beta phase.
2919
2920 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2921 file having crab starfield, but also for all following files - fixed
2922
2923 - MTaskList::PrintStatistics can now be instructud to print also the
2924 title, too: use PrintStatistics(0, kTRUE)
2925
2926 - Changed the image cleaning so that pixels with to many 'used'
2927 neighbors are left used (to get rid of 'holes' in events)
2928
2929 - Introduced more output to the camera displays
2930
2931 - Added an array of histograms (eg one hist per run), MHArray
2932
2933 - Added a _preliminary_ version of the reader for CT1 PreProc files
2934 (MCT1ReadPreProc)
2935
2936 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2937 (thanks to Raquel)
2938
2939 - added the first energy estimator (MEnergyEstParam, estimate.C,
2940 estfit.C) using a parametrization
2941
2942 - Added some new Monte Carlo paremeter containers used to store
2943 setup information from the MC chain (MMcConfigRunHeader,
2944 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2945
2946
2947
2948 *** Version 0.7 (2002/04/30)
2949
2950 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2951 the pedestal mean value was saved incorrectly. For files from
2952 this versions we substract 0.5 from the pedestal mean.
2953 WARNING: This may effect your results, so don't wonder...
2954
2955 - First implementation of an algorithm using only triggered events
2956 for the collection area calculation
2957
2958 - Ascii Output can now also be used for parameter containers which
2959 doesn't overload MParCointainer::AsciiWrite
2960
2961 - The Ascii Output is now also capable of writing single data members
2962 of one container
2963
2964 - You are now able to change the order of the values written to the
2965 ascii file
2966
2967 - You can now specify a conversion factor for each data member written
2968 to an ascii file. This may be usefull to change the units of the
2969 data member (eg. degrees instead of millimeters in case of the
2970 hillas parameters)
2971
2972 - Replaced old MHillas by a new structure which allows you to extend
2973 the parameters stored in MHillas very easily:
2974 see MHillas and MHillasExt
2975
2976 - Added classes to handle source dependancy of image parameters:
2977 see MHillasSrc
2978
2979 - Added container (MBinning) to have a standard input for the binning
2980 in different histograms (eg. the Energy bins should be the same in
2981 all histograms)
2982
2983 - Changed Hillas histograms from mm to deg
2984
2985 - Added the flexible binning to the hillas histograms
2986
2987 - Added a filter for the alpha parameter (MFAlpha)
2988
2989 - It is now possible to write single data members of a class object to
2990 an output stream instead of the whole container only
2991
2992 - Added a generalized filter for a data member:
2993 MFDataMember filter("MHillas.fWidth", '<', 0.5);
2994
2995 - Added a generalized Filter parser for more difficult filter rules
2996 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
2997
2998 - Added new Monte Carlo histograms:
2999 MHMcEnergyImpact and MHMcEfficiency
3000
3001 - Added many new histograms needed for the flux calculation.
3002
3003 - Added a generalized histograms which can fill and show up to three
3004 data members in either a one-, two- or three-dimensional histogram, eg:
3005 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3006
3007 - Added:
3008 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3009 * calculation of <Theta> as a function of time (MHThetabarTime)
3010 they are needed in the flux calculation in
3011 order to select for a given bin in Theta (or time) the appropriate
3012 effective collection area, which is assumed to be given as a function
3013 of Theta and the true energy
3014
3015 - Added calculation of the migration matrix in the energy
3016 (MHMcEnergyMigration):
3017 the migration matrix describes the migration from the true (E_true)
3018 to the estimated energy (E_est); it is needed to determine the
3019 distribution of E_true from the measured distribution of E_est
3020 by unfolding
3021
3022 - changed the color palette in the camera display to DeapSea.
3023
3024
3025
3026 *** Version 0.6 (2002/01/15)
3027
3028 - Introduce the option of disable pixels (MBlindPixels and
3029 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3030 able to deal with Star Field NSB.
3031
3032 - Fixed a bug in the pedestals substraction
3033
3034 - Introduced verbosity levels
3035
3036 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3037
3038 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3039 work correctly (thanks to Abelardo)
3040
3041 - Introduced correct treatment of the diffuse Night Sky Background
3042 and NSB (MMcPedestalNSB)
3043
3044 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3045
3046 - Introduced MMcRunHeaders which contains monte carlo run informations
3047
3048 - Added a 'Print'-Task (MPrint) which calls the Print function
3049 of a parameter container for each event
3050
3051 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3052
3053 - changes to be more efficient with root 3.02/06
3054
3055 - root 3.02/06 fixes:
3056 + the memory leak when reading MRawEvtData
3057 + loosing more time than necessary to update the progress bar
3058
3059 - MWriteAsciiFile is now capable of writing more than one container
3060 in a line. For example: To be able to write Monte Carlo and
3061 Hillas values (energy and alpha) in one line.
3062
3063
3064
3065 *** Version 0.5 (2001/11/06)
3066
3067 - Added new GUI functionality (Analysis)
3068
3069 - Added a camera display to be able to display events in the camera
3070 together with the calculated hillas ellipse
3071
3072 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3073 object at any state of the analysis, so that the output are several
3074 states
3075
3076 - Fixed a bug in the collection area error calculation
3077 (Thanks to Ciro and Abelardo)
3078
3079 - Fixed a bug which causes merpp to crash in some environments
3080
3081 - Implemented auto enabling scheme for Branches to speed up reading
3082 a lot (see MReadTree and MTask)
3083
3084 - Fixed a bug in the Histogram classes which caused histograms to
3085 be written to a file by MWriteRootFile without request
3086
3087 - changed the object I/O from the old stylish root I/O to the new
3088 'auto evolution scheme' This was done only for classes which are not
3089 yet used in Monte Carlo files, so that these files are still readable.
3090
3091 - Added support for a progress bar in MEvtLoop and MReadTree
3092 (see the Analysis Window in Mars for an example)
3093
3094 - Fixed a bug in the package creation which disturbed the conversion
3095 between a mars version unpacked from a tar file and the repository.
3096
3097 - Changed the code to writer merpped (converted into root format)
3098 raw files, to get faster (around 10%)
3099
3100
3101
3102 *** Version 0.4 (2001/09/20)
3103
3104 - This release is made to compile on a root version >= 3.00
3105
3106 - Fixed a bug which causes MReadTree to read the first file only
3107
3108 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3109
3110 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3111
3112 - Added a task to write several container to a root file (MWriteRootFile)
3113
3114 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3115
3116 - Added calculation of the collection area (MMcCollectionAreaCalc)
3117
3118 - fixed some bugs in the Hillas calculation
3119
3120 - added filters to be able to control the task execution dependent on
3121 a parameter (for example: the number of level 1 triggers in a MC-file)
3122
3123
3124
3125 *** Version 0.3 (2001/04/23)
3126
3127 - Many demo macros added
3128
3129 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3130
3131 - Hillas Calculation added
3132
3133 - Standard image cleaning available
3134
3135 - MReadTree is now able to handle more than one file
3136 (Remark: of the same structure)
3137
3138 - Now we are able to display events in a first version of the
3139 Camera event display. To do this we must run the macro
3140 "macros/readCT1.C" to read data from CT1.
3141
3142
3143
3144 *** Version 0.2 (2001/01/24)
3145
3146 - First Implementation of a Gui to read the raw data. Start the
3147 gui with the command mars.
3148
3149
3150
3151 *** Version 0.1 (2000/12/20)
3152
3153 - First official release 0.1