source: trunk/MagicSoft/Mars/NEWS@ 9345

Last change on this file since 9345 was 9345, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 130.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * There is no need to re-run any data because no change took place which
8 could have an effect on the output. However, if you want a
9 meaningful SrcPos plot for your MCs in sponde you must re-process
10 star for your MCs first.
11
12 ;general
13
14 * fixed a few small bugs which could cause the display to crash in ganymed
15 and sponde
16
17 * in sequence file the date can now be omittet. In this case the
18 leading date with the underscore is missing in the expected filename
19
20 ;automation
21
22 * added magnetic field Azimuth direction (ARRANG), currently
23 at ~ -7deg at La Palma
24
25
26 ;database
27
28 * plotdb.php: added default (sequences) for startup, added possibility
29 to set size of plot
30
31 ;merpp
32
33 * added support for Arehucas Version >= 200812140
34
35 ;mars
36
37 * The display now also displays the trigger pattern
38
39 ;ceres
40
41 * added a uniformly distributed one-bin time jitter for the start of the
42 digitization. Otherwise the first photon would be digitized always with
43 the same alignment to the bins
44
45 * Added a plot showing the production height of the photons
46
47 * Moved the particle id from the event header to the run header
48
49 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
50
51 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
52
53 * Added many new options to control the tasks. For deatils see ''ceres.rc''
54
55 * Removed obsolete plots in pedestal and calibration mode
56
57 * Removed the non-NightSky photons from the plots where they are just
58 disturbing
59
60 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
61
62 * The daq event number now represents the readout number
63
64 * The camera ''electronics'' can now be ''switched off''
65
66 * A new tab ''info'' now display basic things like the reflector
67 layout
68
69 ;star
70
71 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
72
73 ;sponde
74
75 * The SrcPos plot for your MCs was so far meaningless because it just
76 displayes the MSrcPosCam data from the input star-files. Unfortunately,
77 this containes was never written to the star-files yet.
78
79 * A new Tab 'OnTime' is available which is an effective on-time
80 fit as in star but for all data. This is mainly for manual cross-check
81 of the effective on-time
82
83 * In some circumstances it might be necessary to re-calculate the
84 eff. on-time from the fit in the new tab, e.g. when a zenith distance
85 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
86
87 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
88 it to its own output file (for convinience)
89
90
91
92== Version 2.2 (2009/01/30) ==
93
94 ;SUGGESTION
95
96 * This release doesn't contain a major change which is expected to
97 change your results. Nevertheless there are small changes to
98 the calibration which can effect at least the first few hundred
99 events in any (mainly MUX and even more SUM) sequence a little bit.
100 So it is recommended although not necessary to reset your sequences
101 in the database before further processing.
102
103 ;NEW
104
105 * A first implementation of a Monte Carlo simulation program
106 (ceres - Camera Electronics and REflector Simulation) has been
107 implemented. It can simulate a full telescope already including
108 a complete reflector simulation and a flexible trigger and readout
109 simulation. Currently, no perfect setup is implemented and
110 especially the output of the program (data structure) should
111 be considered alpha state. Also the user interface is not yet
112 ready.
113
114 ;general
115
116 * All command line options after -- are now interpreted as
117 arguments (usually everything which doesn't start with a minus)
118 rather than options (usually everything which starts with a
119 minus). This allows to use file names starting with a -
120
121 * In all resource files you can now initialize the random number
122 generator. For details see: MJob::InitRandomNumberGenerator
123
124 * added a new program called ''readcorsika''. It's purpose is (in analogy
125 to readraw and readdaq) to read a Corsika output file (for now
126 only cherenkov output is supported) and print its contents in a
127 human readable form. It can also write the contents of this file
128 into a root-file.
129
130 * The calculation of the maximum distance to the origin in a MGeomCam
131 has been improved (edges might be further away than the sides).
132 This is just a tiny change but it might change the appearance of
133 the radial profiles a little bit.
134
135 * The default binning of the center-of-gravity plot has slightly been
136 increased
137
138 ;Database
139
140 * Added informations about the DC currents (fMinCurrents, fMedCurrents
141 and fMaxCurrents). The values are retrieved from the plots showing
142 the average DC currents of all pixels versus time.
143
144 * Websites with tables have now the opportunity to remove lines
145 ('-' button at beginning of each line) and get all lines back
146 ('+' at top of the column)
147
148 * Websites: added option to query only sequences containing sumtrigger
149 events
150
151 * Websites: added option to group by date (year, month, night) for runs
152 and sequences and enabled that combining of different group-bys,
153 e.g. status, date and source is possible
154
155 ;automatic analyis
156
157 * Rewritten producing plots in the web.
158 New plots, namely the output of plotoptical.C (extinction curve from
159 KVA), plotstat.C (status of the automatic analysis (percentage of
160 processed, analysed data etc.)) and plotusage.C (statistics of the
161 condor usage in the data center) has been are available now next to the
162 plots of plotdb.C
163 Mean values from the plots (output of the macro) are provided in a
164 txt file now.
165 The creation of the plots for callisto, star and ganymed in the web is
166 now steered via database. Consequently the plots are faster and
167 reliable up-to-date.
168 For all plots, a new layout is available facilitating the browsing
169 through the plots and providing additional information on the
170 displayed values. (tabs.php) These plots are linked from the DB
171 websites and the wiki.
172
173 ;statusdisplay
174
175 * The ''Loop'' entry in the menu bar now contains an option to pause
176 the loop and to process single events.
177
178 ;merpp
179
180 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
181 instead of RunHeaders)
182
183 * Now allows to merpp files newer than 2008/09/03.
184
185 * Added fixes for wrong (wrong or double) run- and file-numbers
186 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
187
188 ;callisto
189
190 * Extracting the pulse position for the pulse position check events
191 with sum trigger were denied. This decreased the statistics
192 extremely and therefor the resulting puse position was calculated
193 quite weak. Now sum events pass the calculation if and only if they
194 have also a level 1 trigger.
195
196 * the extraction of pedestal events and pulse position from the
197 first data events is now more automatic and makes sure that
198 a more precise number of events is extracted independent of
199 the ratio with which pedestal events or events with signals
200 are contained in the data.
201
202 * Updated Muon calibration constants for all MUX data (teh changes were
203 all smaller than 5%)
204
205 ;star
206
207 * For the calculation of the effective on time all sum-triggered events
208 were skipped. Now all Level1-triggeres events will pass. This might
209 result in a slight inaccuracy of the effective on time.
210
211 ;ganymed
212
213 * If the source position is more than 1deg away from the camera
214 center an error is raised now.
215
216 * Hopefully fixed the bug ''ganymed crashes when resized''
217
218 ;sponde
219
220 * Fixed a problem which causes the fitted spectral slope to be displayed
221 incorrectly. If you use MJSpectrum::FormFlux in your macros make
222 sure that the parameter 0 of your fit is negative.
223
224 * Added a histogram showing the read source position of your MCs
225
226
227
228== Version 2.1.1 (2008/08/04) ==
229
230 ;Database
231
232 * Added the median number of photo electrons from the calibration
233 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
234 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
235
236 * Added fTotOnTime, which is the on-time as given by the run-headers
237 (in contradiction to fAbsOnTime which comes from CC)
238
239 * Added new primaries for the new data structure (Magic II): for the
240 tables dealing with sequences (SequenceBuild Status, Sequences,
241 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
242 this is the telescope number (fTelescopeNumber) for the tables dealing
243 with runs (RunData and RunProcessStatus) this is in addition the file
244 number (fFileNumber)
245
246 * Added column fPriority to the status tables to be able to steer the order
247 in which the data is processed. As default the run, sequence and dataset
248 number are used.
249
250 ;automatic analyis
251
252 * Adapted scripts to the new data structure: They can handle now different
253 telescopes (getting the information as usual from the database).
254 The paths for Magic 2 are not yet implemented.
255
256 ;general
257
258 * should work now with root 5.20/00 (please note that root 5.20/00
259 we encounter crahses in the status display which are ot yet
260 understood)
261
262 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
263 instead of the base name of the file. This makes them easier to
264 access from the code
265
266 * Default Monte Carlo names in MSequence do not require the _E at
267 the end anymore
268
269 * where abrrevating a sequence file with a sequence number is possible
270 also "telescope:sequence" is now accepted, e.g.:
271 star 2:2000123 --out=output
272 see the programs' help for more details.
273
274 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
275 from the database. See the constructors for more details.
276
277 * MReadTree now supports friends
278
279 * MReadTree can now read also files not written by MARS and store
280 the data encapsulated in emulated MParContainers
281
282 * added a new starguider calibration valid since 15.1.08
283
284 ;showplot
285
286 * showplot can now read more than one file at once. This is especially
287 inetersting if reading files containing pure canvases
288
289 ;merpp
290
291 * we merpp the dc currents now also from the camera reports (they have
292 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
293
294 * In the automatic analysis we omit merpping of the currents from the
295 caco files and use the lower rate camera reports from the cc files
296 instead
297
298 * merpp has been redisigned to allow merpping of the cc-reports
299 of a whole sequence. This allows to design a very simple analysis:
300 mkdir output
301 ./callisto 100776 --out=output
302 ./merpp 100776 output
303 ./star 100776 --ind=output --out=output
304 Instead of the sequence number also sequence files are accepted.
305
306 * Implemented a fix for run-numbers between 1001348 and 1001396
307 which were incorrectly assigned by the cc.
308
309
310 ;callisto
311
312 * added a filter again which was was removed in the last release.
313 it removed the most brightest events. This should not change
314 any analysis result because these events are so bright that
315 they cannot be analysed anyway, but the bad-pixel plots doesn't
316 show outliers.
317
318 * updated muon calibration constants for the periods 51-57,
319 58-63 and 67-
320
321 ;star
322
323 * The camera currents are now displayed with the rate of the camera
324 reports instead of the caco reports
325
326 ;ganymed
327
328 * if mc camera files are new enough (>=8) the source position in the
329 camera is now calculated from the stored telscope and shower
330 orientation (Note, that this might not be suitable in all cases
331 depending on the aim of the study. These case still needs
332 implementation)
333
334
335
336== Version 2.1 (2008/06/18) ==
337
338 ;Database
339
340 * introduced average temperature and wind speed from star-files
341
342 * introduced average values from Pyrometer (mainly Cloudiness)
343
344 * introduced the ratio of accepted calibration events in the
345 calibration run
346
347 * introduced the average rates of the different trigger pattern,
348 e.g. the rate of pedestal and calibration events, from the signal-file
349
350 ;general
351
352 * fixed GroupBy options in plot*.C macros
353
354 * only display KVA points (not the Tuorla points) in plotoptical.C
355
356 * all programs now allow to add resources to the ones from the resource
357 file or overwrite them from the command line. This can be done like this
358 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
359 if something seems to be wrong you can debug what the program is doing
360 using the option --debug-env=3
361
362 * increased the diversity of debug levels. That also means that with -v3
363 you get now less output, i.e. only the output which is important for
364 an analysis. To get more output which helps for debugging try 4, 5 and 6.
365
366 * fixed a problem in the task synchronizing the reading of the reports
367 and the data stream. The effect was that in some circumstances the last
368 events of some trees could have been skipped. Since this is only a
369 very tiny part of the data no severe effect to your analysis results
370 is expected (an exception might be very short, i.e. singel runs,
371 datasets).
372
373 * Dataset file now allow to include the sequence file directly within
374 the dataset file and also allow to exclude single runs from the dataset.
375 (for more details see Class reference of MDataSet)
376
377 * Sequence files now allow for excluding runs from the analysis
378 (for more details see Class reference of MSequence)
379
380 * added code to process the sum-trigger flag
381
382 * the histogram classes MH3 and MHn now support profile histograms
383
384 * the histogram classes MH3 and MHn now support labels at the axis
385
386 * the Random Forest Train-classes (MJTRain*) now store the used datasets
387 in the output file
388
389 * the MFMagicCuts have a new option to allow a linear area cut (for
390 special studies)
391
392 * The liniking of the shared object is now done into a file defined
393 by 'mktemp'. This should be a local file system which accelerates
394 liniking a lot.
395
396 * The code has been prepared for compilation with root 5.18/00d
397
398 * The MHEnergyEst histogram now shows the distribution of
399 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
400 and (Eest-Emc)/Emc vs Emc.
401
402 * fixed mars (event display) for merpped raw-data and MC data
403
404 * adapted the synatx of sequence files to allow for the new run/file
405 scheme. For more details see class description of MSequence
406
407 ;showplot
408
409 * Added support for tiff files
410
411 * Added support for csv files (tables containing tab number,
412 name and title)
413
414 * Tabs now can have a title which is displayed in the postscript file
415
416 * When multiple file are written at once (e.g. pngs from a display)
417 it is now possible to use the tab name and or tab number in the
418 file name. For details see showplos's help.
419
420 ;merpp
421
422 * Implemented cc file version 2008-02-20/0
423
424 * Implemented cc file version 2008-05-19/0
425
426 * With new options merpping can be restricted (in addition to the
427 run-number) also by telescope and file number.
428 For details see "merpp --help"
429
430 * Implemented raw data format 11 (the most important change, except
431 from plenty of changes in the format definition, is the addition
432 of the file-number in the header) If nobody makes a mistake this
433 format should have the advantage that it is by definition forward
434 compatible, so old programs will be able to read newer formats.
435
436 * Added Pyrometer information to default output (stored in a new Tree
437 Pyrometer, needs a complete new merpp, i.e. new calibration)
438
439 * Merpping (also update) can now be restricted to one single report.
440 For example:
441 If you want to update an old file with Pyrometer information call
442 merpp --only=Pyrometer --update
443
444 ;callisto
445
446 * in the pedestal processing now at least 50 processed events are
447 required for succeeding.
448
449 * the signal and calib files now contain also the sequence information
450
451 * the two MPedestalCam in the calib file now have proper names
452 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
453
454 * Both pedestal cams now contain the number of events processed
455
456 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
457 i.e. for the extraction of the calibration pulses basically the average
458 over all events of the first slice instead of all slices was used.
459 Since pedestal and calibration constants are continously recalculated
460 this only effected the very first events of every sequence.
461
462 * For the extraction of the position of the maximum sample now the
463 extraction range is set automatically to the extraction window,
464 before the whole accessible range was used.
465
466 * If the number of samples in the events and the number of samples
467 in the run-header disagrees now an error is raised (this can
468 happen in not well simulated Monte Carlo files)
469
470 * In the case of MUX-data pedestal events with the lvl1 trigger flag
471 could survive into the pedestal calculation -- fixed.
472
473 * Tab "TrigPat" added showing the distribution of the trigger pattern
474 as found in the run-files (normalized with the run length)
475
476 * The selection of events from the trigger pattern has been improved.
477 If the trigger pattern is corrupted events won't pass anymore.
478
479 * Added a new command line option --dev-null to suppress output of
480 Y-files (this is useful for test cases)
481
482 * added a new tab "CalPos" showing the arrival time of extracted
483 interleaved calibration events
484
485 ;star
486
487 * the star file now contains also the sequence information
488
489 * Added a new command line option --dev-null to suppress output of
490 I-files (this is useful for test cases)
491
492 * Tab "Rate" added showing the distribution of the trigger pattern
493 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
494 the Y-files (normalized with the run length)
495
496 * The effective on-time calculation doesn't use events with only
497 sum-trigger anymore
498
499 * The data in the MHWeather tab has been reorganized. The never
500 working solar radiation has been removed and the data from
501 the pyrometer (cloudiness, air and sky temperature) is
502 displayed in addition.
503
504 ;ganymed/sponde
505
506 * Now data points are even shown correctly if they have error bars larger
507 than one sigma. Points with null or negative significances are omitted.
508
509 * DrawNicePlot now allows to set a projection range
510
511 * Updates pointing models. One is applied after the implementation
512 of the new LUTS in August, the other one is applied after the
513 next major change of the pointing model in October. Note that
514 these models are preliminary and give wrong results below Zd=65deg
515
516 ;sponde
517
518 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
519
520 * a new option "--force-runtime" is available. In case of very short
521 datasets (for light-curves) which are in the order of a few
522 minutes the calculated effective on-time is not very acurate because
523 it is quantizised in the order of a minute. Therefore you can switch
524 to using the real run-time instead (remakrt: this ignores any
525 dead-time!)
526
527 * a more analytical way is used to "fill" Monte Carlos into regions
528 of impact parameters which have not been simulated because the
529 trigger efficiency is assumed to be 0.
530
531 * estimated sensitivity curves for hi and lo zenith angles are shown
532 scaled to the correct observation time and collection area
533
534 * the Monte Carlo events after cuts are now written to the output file
535 if an output file given
536
537
538
539 *** Version 2.0 (2007/09/03)
540
541 - database: the position used for the pulse pos check was missing
542 in the callisto output and could thus not be filled into the DB.
543 Also the old values seemed not exactly the PulsePos used for
544 teh check.
545
546 - general: Resource file now allow an Include-Resource, i.e. you can
547 read a resource file with default settings, include it in your
548 resource file and overwrite the settings in your file. More than
549 one include file is allowed. Inclusions can be iterative.
550 Include: mydefaults.rc yourdefaults.rc
551 The resources in the first file have higher priority than the
552 second file.
553
554 - general: Now the output files (calib*.root, etc) also contain the
555 resource file (to check it open it in the TBrowser and choose Print()
556 from the context menu)
557
558 - general: Dataset files now allow to overwrite the default path
559 to search for sequence and data files. Note, that the program
560 option and individual resources will overwrite it. For example:
561 SequencePath: /magic/montecarlo/sequences
562 DataPath: /magic/montecarlo/star
563
564 - general: Fixed a problem with variables in MDataPhrase. It seems
565 that only optimdisp (didn't work) was effected.
566
567 - general: Some improvements to the optim and train processing. For
568 example the ststud window now got a proper title.
569
570 - general: The "Status Display: " was removed from the window title
571 within an Eventloop.
572
573 - general: added a new flexible histogram-class (MHn) which can be used
574 for example in testing after optimizations or training to produce
575 user defined histograms.
576
577 - general: The Random Forest now allows attaching an evaluation
578 function which is applied to its output. This allows to train
579 on whatever you like (eg. train on log10(energy), but return
580 energy)
581
582 - general: The Random Forest training of energy (trainenergy.c) and
583 disp (traindisp.C) has been improved by more graphical output to
584 judge the result.
585
586 - general: The training of energy (trainenergy.C) has been improved
587 a lot by training on a different quantity than energy. It gives
588 a result which is highly independant of the source spectrum
589 and shows lower bias than all other options.
590
591 - general: Dataset files are allowed to contain collections of
592 datasets. For more details see the class reference of MDataSet.
593
594 - general: The default WobbleMode in a datset file now (if not
595 overwritten) is "auto", i.e. wobble mode is set if the dataset
596 doesn't contain off-sequences.
597
598 - merpp: Merpp can read file format version 9 now. Please realize
599 that for file format version 9 the extraction range is different
600 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
601 the first and last 15 slices have been removed from all MUX data.
602
603 - mars: Similar to writing movies you can now select events which
604 should be displayed in your display. Therefore add the following
605 lines to your mars.rc:
606 MFEvtNumber.FileName: ganymed00223552.root
607 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
608 The input file can be a ganymed-file after (ganymed*.root) or
609 before (ganymed*-summary.root) file. For example to select all events
610 from your on sample after cuts (excluding the ThetaSq cut) use
611 MFEvtNumber.Selector: DataType.fVal>0.5
612 To show all events from your on-sample after quality cuts
613 use the summary file instead.
614
615 - mars: new ways to call mars are implemented. Instead
616 of calling
617 mars filename.root
618 you can now also use
619 mars sequence.txt
620 or
621 mars sequence.txt inputpath
622 or replace sequence.txt by the sequence number if the default
623 sequence file should be used.
624
625 - mars: The default size has been increased
626
627 - mars: There are two new heckboxes which allow to switch off
628 the calculated image parameters
629
630 - callisto: was broken for MCs... fixed.
631
632 - callisto: improved calculation of spline coefficients a lot. This
633 leads to a further improvement of the event rate calibrating MUX
634 data of about 15% (175evt/s instead of 150evt/s)
635
636 - callisto: finally the raw data we read is now real 16bit (with
637 10bit precision) for MUX data and not a stripped 8bit number
638 anymore. Due to scaling of the numbers (without precision loss
639 into an [0-256[ range, the final numbers for pedestal, pedestalrms
640 and extacted signal don't change. However, at all places where
641 raw data is directly accessed (eg. saturation and variation
642 limits in the signal- and pedestal-extraction) the numbers
643 refer still to the data's 16bit range.
644
645 - callisto: The maximum arrival time difference used in the bad
646 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
647 for both, old FADC and MUX-FADC, data.
648
649 - callisto: Be aware that callisto is now calibrating the arrival time
650 in nanoseconds rather than time slices. Also all following tasks
651 have been changed to assume ns units now. If you star data
652 calibrated with an older version it might be necessary to adapt
653 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
654 to obtain optimal results. The plot in the PulsePos tab
655 will now be in ns, too. This might also mean that the Muon
656 analysis in star might not work as perfect as expected as long
657 as old files read in.
658
659 - callisto: The calibration constants of earlier updates got lost
660 somehow. All constants have been updated.
661
662 - star: The PSF is now determined from the profile of the ArcWidth
663 instead of arcwidth/radius. The old way gave to much weight
664 to the bins with low statistics. The reference lines have been
665 updated.
666
667 - star: For speed reasons events suitable for the muon analysis
668 are now also preselected by fConcCOG<0.1 which seems to be a very
669 good preselector for muons.
670
671 - star: is now calculating a new timing parameter the Slope along
672 the major and minor axis of the shower. Therefore a numerical
673 solution of a line-fit is used. To use MHillasExt.fSlopeLong
674 and MHillasExt.fSlopeTrans don't forget to multiply it with
675 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
676
677 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
678 have been removed from MNewImagePar. They have never been good for
679 anything.
680
681 - star: Implemented a new recursive algorithm which is supposed to be
682 faster. Also implemented new cleaning oiptions, which are:
683 + CleanLevel0:
684 The cleaning level above single core pixels can be kept
685 + KeepIsolatedPixels:
686 Define whether single core pixels should be kept
687 + TimeLevel1:
688 The coincidence window in nanoseconds to single used neighbors
689 + TimeLevel2:
690 The coincidence window in nanoseconds to two used neighbors
691 + PostCleanType:
692 MOde in which a time dependent post cleaning should be applied
693 0: No post cleaning
694 1: Require for each used pixels at least one used neighbor
695 within a time-window of CleanLevel1
696 2: Require for each used pixels at least two used neighbor
697 within a time-window of CleanLevel2
698 3: Require first two and second one used neighbor
699 within a time-window of CleanLevel1 and fCleanLevel2
700 respectively
701 + RecoverIsolatedPixels:
702 - recoveres isolated core pixels if they have a used neighbor
703
704 - mars/star: The new default cleaning is:
705 + CleanLevel1: 6.0
706 + CleanLevel2: 3.0
707 + CleanTime1: 1.75
708 + CleanTime2: 1.75
709 + PostCleanType: 3
710
711 - star/ganymed: The old spark-cuts have been replaced by new ones.
712 These new spark cuts have been cross checked with the sequences
713 84720 (before splitter), 101041 (after splitter) and 223539 (new
714 FADCs). In all cases they seperate pretty well, but of course not
715 perfect. Monte Carlos have suggested to tighten the cuts a little
716 bit further at low sizes. This has been done.
717
718 - ganymed: IMPORTANT - The spark cuts have been changed to match
719 all available data more or less well. This might mean that for
720 YOUR data there are still sparks visible.
721 Whenever you do an analysis you have to make sure that NO sparks
722 survive your cuts!
723
724 - ganymed: The old hadronness and size cuts have gotten new indices
725 (10, 11). The old indices 8 and 9 now mean an additional condition
726 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
727 If you want to switch off this cut just move the line far away enough,
728 e.g. by setting c[9] to -500. Please update your ganymed.rc files
729 accordingly!
730 The unit of c[9] is deg. It is the dist at which your cut will
731 cross the slope==0. The unit of the slope is ns/deg. So if
732 you readin files calibrated with an older Mars-version you
733 have to adapt the default value for c[9] to the FADCs:
734 - Multiply by two for the MUX FADCs (run number > 200.000)
735 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
736 - Multiply by 42 for the meaning of life (run number = 200.000)
737
738 - ganymed: The old Cut0 is now called CutQ and is calculated before
739 the source position is caluclated. If you need a quality cut
740 including source dependant data (be very carefull with this!)
741 you have to use Cut0 instead.
742
743 - ganymed: now properly supports three off regions in wobble mode.
744 It will be the default from now on in ganymed_wobble.rc. To change
745 the number of off-regions use
746 NumOffSourcePositions: 1
747 in your ganymed.rc. Also by default no off-theta cut will be done
748 anymore so that you will get a background level higher than the
749 signal level in your ThetaSq plot for ThetaSq>0.2.
750 Due to this be carefull changing the scaling mode away from
751 "None". You will underestimate your signal if your scale interval
752 is not properly set.
753 (Rem: ThetaSqN is no longer needed)
754
755 - ganymed: is now storing the events of all (on- and off-)
756 source positions even in the case of more than one off-source
757 position. This should allow sponde to work properly and the
758 energy estimation is done correctly in all cases (without any
759 "nearest position" trick)
760
761 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
762 with a real pointing model for the starguider is done, calibrated
763 with more than thousand tpoints taken from this date on.
764
765 - ganymed: was broken for Wobble-MCs... fixed.
766
767 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
768 has changed. Note that your old ganymed.rc will be incompatible
769 with the new algorithms! Please check the ganymed.rc files and
770 the class description of MFMagicCuts for more information.
771 It is recommended at the moment to use identical Disp-Parametrizations
772 for on/off- and wobble-mode. If cuts are optimized only
773 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
774 should be optimized. All other values should be kept as they are.
775 If you want to do an anylsis without timing a parameters, you can
776 switch off the timing cuts by seeting parameter 7 to a very small
777 value (eg. -99). To remove the slope parameter from the disp
778 paremtrization set parameter 8 to 0.
779
780 - ganymed: The distribution of observation time versus zenith
781 angle is now shown for off- AND on-data.
782
783 - ganymed: The contents of the source position plot are no longer
784 averaged, thus a lot of (fake) events between the two wobble
785 positions have disappeared.
786
787 - ganymed: There is a new tab "CutT" it contains the VsSize plots
788 with the CutT, whihc is defined in ganymed.rc, applied. It
789 is resonable to use your theta-cut for it, to see if there is
790 something strange (sparks!) in your signal-region.
791
792 - ganymed: To choose a dataset from a collection in a dataset file
793 use the new command line option "--dataset=12345"
794
795 - optim, sponde: should now properly support three off-regions.
796 Just produce your ganymed summary files with three off-regions.
797 optim and sponde will automatically get all off events from
798 all off-regions from this file. Please do not forget to
799 set the scaling in optimwobble.C properly:
800 fit.SetScaleUser(1./3);
801 it is not yet read in automatically (will follow soon).
802 In the case of fixed Scale you can also use
803 cuts.SetThetaCut(MFMagicCuts::kOn);
804 no off-cut needed.
805 Be carefull in case of three off-regions when switching on
806 scale mode. Make sure that the scale interval is set correctly.
807
808 - sponde: sponde.rc and sponde_onoff.rc are now idetical
809
810 - sponde: the resouce files have been rewritten with a lot of
811 comments and a well working parametrization for an energy estimator
812
813 - sponde: In the estimated energy versus monte carlo energy plot the
814 contents where exchanged.... fixed.
815
816 - sponde: the so called "accurate"-mode has been removed. It didn't
817 give any improvement in accuracy, only decreased execution speed.
818
819 - sponde: the so called "simple"-mode has been removed. It didn't
820 give any improvement in simple.
821
822 - sponde: the so called "refill"-mode has been removed. It was anyhow
823 not implemented.
824
825 - sponde: now checks whether the theta distribution of your on-data
826 and the theta-distribution of your Monte Carlo sample (after
827 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
828 sample is incomplete) execution is stopped. Execution can be forced
829 using the new option --force-theta. Use this option with care!
830
831 - sponde: Proper collection areas can now be constructed also from
832 Monte Carlo samples generated with different maximum impact
833 parameters. Note that in previous version you neither got
834 a warning or failure, nor was there any obvious sign that the
835 collection area was overestimated due to usage of files with
836 different maximum impact parameters.
837
838 - sponde: If MC files with different lower energy limits are used
839 the primary MC spectrum is artificially completed down to the
840 lowest energy used at all. WARNING: that this gives correct
841 collection areas ONLY if none of the events in this region would
842 survive your cuts at all.
843
844 - sponde: the output file now contains more information about
845 the spectrum (eg. the full 2D collection area histogram).
846 Note, that this information can only be written to the file
847 if it is stored automatically via command line argument.
848 If you only store the status display from within the display
849 the information is lost.
850
851 - sponde: added a new tab "Disp". It shows the residual of the disp
852 (Disp-Dist) versus several parameters and it is meant to judge the
853 quality of the disp estimator. In the ideal case the residual is zero
854 and doesn't depend on any variable. The tab is displayed after
855 CutQ and Cut0.
856
857 - sponde: added a new tab "Energy". It shows the residual of the
858 energy (lg(estimated energy)-lg(monte carlo energy)) versus
859 several parameters and it is meant to judge the quality of the
860 energy estimator. In the ideal case the residual is zero
861 and doesn't depend on any variable. In reality even a good estimator
862 can show residuals versus Monte Carlo energy. The tab is displayed
863 after all cuts.
864
865 - sponde: added a new tab "EventDist" showing the unweighted real
866 absolute number of events of your sample after cuts. This tells
867 you how many events with this energy you had in your MC files.
868 The same information you get from the error bars of the weighted
869 histograms, but this is less intuitive.
870
871 - sponde: The spectrum plots now show the crab- and 1553-spectrum
872 for comparison. It is not meant to show these curves in
873 publications, they are only for production.
874
875 - sponde: The OriginalMC tree with the events produced by corsika
876 is now processed only once
877
878 - sponde: Finally fixed most annoying bug, which has effected the
879 last bin of the collection area. It was the problem that binnings
880 of root histograms are from 1 to n (included) but there was a C-like
881 loop in sponde from 0 to n (excluded). Now the loop also includes
882 correctly under- and overflow-bins. The worse thing with this is,
883 that for the events in the highest bin not only the bin-content
884 was wrong, but also the weights applied to these events, which could
885 in pricipal effect also other parts of the distribution (eg. due
886 to energy estimation). Fortunately it effected only a few events
887 in most cases.
888
889
890
891 *** Version 1.2 (2007/05/14)
892
893 - database: The database now has two new values Unsuitable50 and
894 Unsuitable01. They express the number of pixels which are
895 unsuitable for more than 50%, respectively more than 1%, of
896 all calibrated event. It is a more accurate number than the
897 previously used numbers, because they only take the first
898 calibration (ignoring the interleaved calibrations) into account.
899
900 - database: The database now has two other new values UnsuitableMax and
901 DeadMax. They express the maximum number of pixels which were
902 unsuitable, respectively dead, during the sequence. Because
903 of high pedestal rms (cars passing) a few events with very high
904 numbers of unsuitable pixels can happen. Not to suffer from this
905 effect we don't take the highest 0.1% of the numbers into account.
906
907 - general: fixed a bug which caused callisto and star to stop working
908 properly because the callisto output was currupted
909
910 - general: a script called scripts/makemovie has been added which
911 simplified the process of producing several movies from a single
912 sequence with different setup.
913
914 - callisto: Some more code cleanup. Started to remove old obsolete
915 code from cvs.
916
917 - callisto: The extraction of the pedestal with the extractor was
918 not random. It seems that extracting at one position is still biased
919 (for example in the first or last slices we could still suffer from
920 switching noise) Now it is completely random.
921
922 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
923 pedestal files) individual pixels could be skipped due to high
924 variations. This was already the case for the pedestal extraction
925 from the lo-gains since the beginning and properly handled
926 there, but was introduced in the extraction from the pedestal files
927 a while ago. To calculate the average value it was still divided
928 by the number of events procesed not by the number of summands
929 really summed. This let to a pedestal which was a tiny amount too
930 small (for a few piels in the order of 0.1%). This led to an slightly
931 positive offset of the randomly extracted pedestal for a few pixels.
932 I doubt that this has a big effect on the result, because the effect
933 on the individual numbers is quite small. Due to this it is suggested
934 that you rerun your calibration to make sure you are without any
935 avoidable bias.
936
937 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
938 the median rms of the absolute arrival time and expressed in significance
939 levels. This replaces the old meaning of an abolute upper limit. An
940 absolute upper limit doesn't make much sense, because in our data
941 all arrival times are shifted at the same time (in fact it might be
942 a shift of the artificial trigger w.r.t. to the light flash).
943
944 - callisto: Added a new tab "BadPixTm" which shows the time evolution
945 of the number of unsuitable pixels over the whole sequence. This
946 is usefull mainly to judge if an intermediate calibration had
947 problems.
948
949 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
950 of the number of dead pixels over the whole sequence. Dead pixels
951 in this context are unmapped pixels, i.e. pixels which could not
952 be interpolated, and thus are ignored in the further analysis.
953
954 - callisto: It is now possible to use the position of the maximum
955 of the spline as arrival time instead of the leading edge even
956 when using the integral for the signal. Therefor set the extraction
957 type to kIntegralRel ("IntegralRelative") and the relative height
958 ("HeightTm") to -1:
959 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
960 MJPedestalC1.ExtractSignal.HeightTm: -1
961
962
963
964
965 *** Version 1.1 (2007/04/27)
966
967 - general: The new class MGeomCamDwarf contains the camera geometry
968 for our prefered Dwarf camera and can be used to create general
969 geometries of roundish or hexagonal cameras.
970
971 - mars: The default cleaning is now abolute 8.5/4.0.
972
973 - mars: The resource file mars.rc now contains examples for MUX data
974
975 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
976 data containing only 10-bit information is still cooked down to
977 8-bit, by cutting away the lowest 8-bit.
978
979 - merpp: When reading raw data the data is now stored in a single
980 array. The lo-gain array is obsolete. The interface stays the same.
981
982 - callisto: To process the new MUX data use the resource file
983 callisto_mux.rc
984
985 - callisto: The -root and -raw options to read merpped raw data have
986 been removed
987
988 - callisto: If the -mc option is given the sequence-name can now be
989 replaced by the MC sequence number
990
991 - callisto: If the sequence file contains "MonteCarlo: Yes" the
992 -mc option can now be omitted
993
994 - callisto: Started further simplification by removing obsolete
995 dependancies on MCalibIntensity*Cams.
996
997 - callisto: removed unsused intensity calibration from MJCalibration
998 for further simplification
999
1000 - callisto: for simplification removed references to
1001 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1002 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1003 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1004 (this should at minimum change nothing at all, and at maximum
1005 improve thing if these containers where somewhere not handled
1006 properly)
1007
1008 - callisto: Added the option to write an event movie. Please use
1009 this option with care (huge files) but exessively to understand
1010 our events. For further documentation please refer to the
1011 IACT wiki
1012 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1013
1014 - callisto: Improved binning for the pulse position check histogram
1015
1016 - callisto: The code calculating the pulse position checknow takes
1017 the pedestal into account
1018
1019 - callisto: The arrival time is now stored with full precision this
1020 helps to get rid of artefacts in histograms. For the signal this
1021 is not necessray because it is displayed in log-scale anyhow
1022
1023 - callisto: Fixed a problem with internal exclusions. Pixels which
1024 have once been marked as unsuitable didn't get the necessary
1025 histograms filled anymore to be rechecked with each interleaved
1026 calibration.
1027
1028 - callisto: The relative arrival time resolution (the rms of the
1029 relative arrival time offset) is now checked against its
1030 median and the median deviation, instead of the average
1031 plus an absolute offset.
1032
1033 - callisto: The relative arrival time offset is now calculated
1034 w.r.t. its median not w.r.t. to an artificial reference pixel.
1035
1036 - callisto: The relative time calibration now marks pixels with
1037 outlaying offset as unsuitable
1038
1039 - callisto: The interleaved relative time calibration has been switched
1040 on. The advantage is that pixels which are marked as outliers
1041 now can recover. An improvement over time is not expected, because
1042 the relative time calibration seems stable.
1043
1044 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1045 option can now be omitted.
1046
1047 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1048 or the option "-mc" is specified as default the monte carlo datacenter
1049 paths (/magic/montecarlo/...) are used if not overwritten in the
1050 dataset file.
1051
1052 - ganymed: The output files now contain run- and event-number for all
1053 events, accessible as RunNumber.fVal and EvtNumber.fVal
1054
1055 - ganymed: Added a plot showing the source position in the camera also
1056 for wobble mode
1057
1058 - ganymed: In addition to the existing task which can be setup to
1059 be executed after Cut1 a final task called "EstimateEnergy"
1060 has been added, executed before writing the final output
1061 (ganymed00000000.root). The task setup in all three cases
1062 can be choosen individually. (For all three(!) cases you
1063 can for example choose MRanForestCalc. For examples see all
1064 sponde*.rc and all ganymed*rc)
1065
1066 - ganymed: If a container "MEstimatedEnergy" is found in the
1067 parameter list (eg. because it was setup by MEstimateEnergy)
1068 it will be written to the output file.
1069
1070
1071
1072 *** Version 1.0 (2007/02/16)
1073
1074 - database: Website to plot values from the database has been added.
1075
1076 - database: The rate of spark events as found by star is now kept
1077 and the rate after cleaning is now with spark events subtracted
1078
1079 - general: The changes to the interpretation of phrases lead to
1080 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1081
1082 - general: Added example files how you can create your own calendar
1083 (eg. as christmas present) with Mars. Just run
1084 root macros/tutorials/calendar.C
1085
1086 - general: Added a possibility to display grouped data in the plotdb.C
1087 macro (and similar macros). This allows to plot hourly, nightly,
1088 weekly, monthly and yearly averages.
1089 For more details see the plotall function of the macro
1090
1091 - general: fixed the error display of the camera display. It showed
1092 wrong results.
1093
1094 - general: fixed a memory leak when reading many MStatusDisplays
1095
1096 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1097 between a spherical and a parabolic mirror
1098
1099 - callisto: We have a new pulse position check which takes the properties
1100 of the extractor automatically into account. So no need to set
1101 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1102 left is done. If possible the lo-gain extraction start and hi-gain
1103 extraction end is changed accordingly. If no proper extraction range
1104 can be set (hi-gain too much to the left) an error is raised.
1105
1106 - callisto: New swapped pixels have been found and corrected
1107
1108 - callisto: Redone the signal extraction this includes:
1109 + Unified the algorithms to extract the pedestal for all pedestal
1110 extractions done
1111 + Unification of hi- and lo-gain into one array
1112 + Unification of hi- and lo-gain extraction for Spline and
1113 Digital Filter (means now exactly the same algorithm is used,
1114 not a copy-and-pasted one)
1115 + Store pedestal subtracted data in a common place
1116 + Improved extraction algorithms. If the algorithms search a
1117 maximum but don't find one they don't return the maximum anymore
1118 + Improved the extraction such that a information for signal
1119 and time which is consistent is returned
1120 + replaced the numerical spline with a (not slower) analytical
1121 solution
1122 + Lowered the saturation limit from 250 to 245 to make sure that
1123 we are far away in all pixels from problems with the clock-noise
1124 + The start of the lo-gain extraction is calculated from the hi-gain
1125 arrival time. In case of saturation an estimation is used.
1126 + the hi-gain window was extended to slice 16. This allows extraction
1127 of very late pulses in single pixels or of huge hadron showers.
1128 + Now uses the lo-gain extraction range for pedestal extraction,
1129 not the hi-gain range in the lo-gain
1130
1131 - callisto: New hi-/lo-gain calibration constants have been produced
1132 for all periods from the statistic of the whole period. They are
1133 now used automatically depending on the periods. The old constants
1134 where deviation in avarega about 2%-3%. The constants are very
1135 stable from period to period (<<1%) except for exchanged channels.
1136 In a few cases the constants used so far were off by 1%-2% (maybe
1137 temperature effects?)
1138
1139 - callisto: To gain obsolete space we do not write the
1140 MPedestalFundamental anymore. Also calibration and bad pixel
1141 treatment is not done for it anymore because it has never been used.
1142
1143 - callisto: Fixed a bug in the seuqence handling which caused the
1144 light condition to be ignored
1145
1146 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1147 basically the same as "Cleaned" but the distribution devided into
1148 the events fullfilling a spark cut or being rejected by it.
1149 This cut can be changed from star.rc (see example inside) by
1150 the "SparkCut" directive
1151
1152 - star: Star displays now the average individual pixel-rate (IPR) versus
1153 time and the average discriminator threshold (DT) of all pixels.
1154
1155 - optim: fixed a problem with the optim-macros which was due to a bug
1156 in the new phrase parsing
1157
1158 - ganymed: To get a nice FalseSource plot (instead of the all-information
1159 debug plot displayed as a standard plot) use the context menu
1160 somewhere between the two upper plots, click on "DrawNicePlot"
1161 and enjoy the result. (It is the same context menu which contains
1162 the other options)
1163 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1164
1165 - ganymed/optim/train: The cut program, trainings- and optimization
1166 macros could run with less files found than expected from the
1167 sequence-files. No the execution is stopped in this case.
1168
1169 - ganymed: now stores the dataset in the output file with all information
1170 contained (as sequence number, sequence path, data path) so that the
1171 used dataset file can be recreated complete from the output
1172
1173 - sponde: now also allows the uasge of random forest
1174
1175 - sponde: added a plot showing the cut efficiency
1176
1177 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1178 errors (eg. effecting the collection area) because the errors of the
1179 two histograms were swapped in the calculation, which makes a difference
1180 in the case the histograms contains weighted events. Aditionally the
1181 totalarea was incorrectly taken into account, which results in too small
1182 errors, which makes a difference at low statistics were the errors
1183 or the collection area dominate.
1184
1185
1186
1187 *** Version 0.10.3 (2006/10/23)
1188
1189 - database: Implemented ObservationMode flag in websites.
1190
1191 - database: For sequences there is now also the stoptime available on the
1192 websites.
1193
1194 - database: Removed ManuallyChanged flag from sequence-info websites,
1195 as it is not needed anymore with the new sequence building algorithm.
1196
1197 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1198 Class for calculation of confidence intervals (upper limits).
1199 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1200 Please read the class instruction of TRolke for more information.
1201
1202 - general: The programs now return 0xfe if the requested resource file
1203 doesn't exist.
1204
1205 - general: Errors comming from root itself are now not output to
1206 stderr anymore but to our default (colored) log-stream.
1207
1208 - general: Changed the interface to TFormula such that now everything
1209 is parsed by TFormula, which should allow to use phrases even
1210 without paranthesis correctly parsed.
1211
1212 - callisto: replaced the AdHoc number of effective integration slices
1213 in the digital filter by an average of the correct number, averaged
1214 over all possible set of weights. This also gives correct numbers
1215 for the lo-gains which were totally wrong before.
1216
1217 - callisto: drastically reduced memory consumption by not storing
1218 all intermediate calibration results in memory anymore (we might
1219 write them into a file in the future)
1220
1221 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1222 debug plot displayed as a standard plot) use the context menu
1223 somewhere between the two upper plots, click on "DrawNicePlot"
1224 and enjoy the result. (It is the same context menu which contains
1225 the "DrawAll" option)
1226 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1227
1228
1229
1230 *** Version 0.10.2 (2006/10/15)
1231
1232 - general: changed the building of the sequence files such, that
1233 the source-/project name in case of wobble-sources is not the
1234 source/project of the first data run anymore but the new generalized
1235 wobble source/project
1236
1237 - general: Added some functions to MAstro to calculate sun and
1238 moon properties
1239
1240 - general: Added two new macros (starvisday.C and starvisyear.C)
1241 which allow to plot the visibility of several stars in one day
1242 or of one star along one year
1243
1244
1245
1246 *** Version 0.10.1 (2006/10/11)
1247
1248 - general: HTML logging output was distorted... fixed.
1249
1250 - general: Changed the writing of the sequencefiles such that only
1251 as many pedestal files as giving at least 1000 pedestal events which
1252 are nearby the first calibration run are used as pedestal runs
1253
1254 - sponde: In the calculation of the collection area(s) and the
1255 distribution for MOnte Carlo and estimated energy the error
1256 calculation was wrong because root didn't take the errors
1257 properly into account... fixed.
1258
1259
1260
1261 *** Version 0.10 (2006/10/10)
1262
1263 - general: all executables now check consistency of the root version
1264 installed with the root version used for compilation. The return
1265 code in this case is 255.
1266
1267 - general: The algorithm to build seqeunces has been redesigned
1268 completly. It is now more flexible in terms of a resource file
1269 resources/sequences.rc which can be used to partly overwrite
1270 the default algorithm and defined the important part of the
1271 algorithm. It also takes correctly into account several ways
1272 of taking wobble-data. Currently the new algorithm doesn't take
1273 the number of pedestal events anymore into account (so a sequence
1274 could have much less than 1000 pedestal events and data runs are
1275 no-more used instead)
1276
1277 - general: a lot of small changes to make the code compatible with
1278 root 5.12/00 and gcc 4.1
1279
1280 - general: Fixed some warnings thrown if more warnings are switched
1281 on in the compiler
1282
1283 - general: Added a function to MMath which returns the Median of
1284 the distribution abs(y[i]-median) but at 68:32 division instead
1285 of 50:50, which is somehow the median counterpart of the rms.
1286
1287 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1288 even if they are compressed with gzip (recommended compression
1289 is with "-1")
1290
1291 - showplot:
1292 + batch mode creation of image files now works with root 5.12/00
1293 + added support for writing bmp (though it never produces
1294 bmp which can be read by programs like xv or gimp)
1295 + added support for xml
1296 + added new option to start the display with a different size, by
1297 --display-width=nnn or --display-height=nnn
1298 + added options to define the canvas size when the display is started
1299 --canvas-width=nnn or --canvas-height=nnn
1300 the option can also be used for batch-mode conversion
1301 + added an option which automatically fits the display size to the
1302 desktop-size: --auto-size
1303
1304 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1305
1306 - merpp: allow the reports to have 1000ms due to a bug in the camera
1307 program.
1308
1309 - callisto: New swapped pixels have been found and corrected. For
1310 details see MRawRunHeader::FixAssignment()
1311
1312 - callisto: Callisto now raises an error if one of the input files could
1313 not be opened.
1314
1315 - callisto: In some rare cases it could happen that in the signal
1316 extraction of the digital filter the extractor returned nonsense
1317 results due a wrong initializion of a variable (this happens in
1318 cases in which the extracted signal is exactly zero or the
1319 digital filter couldn't slide because of a too small extraction
1320 window, which could happen in the lo-gain extraction)
1321
1322 - callisto: The lo-gains have been marked as valid in some cases
1323 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1324 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1325 smaller than the number of slices (fLoGainWindowSize) needed
1326 by the lo-gain extractor
1327
1328 - callisto: Updated absolute calibration constants (muon calibration)
1329
1330 - callisto: fixed a bug which caused the hi-gain saturation not
1331 to be handled properly in the spline (the position of the
1332 saturation was calculated incorrectly)
1333
1334 - callisto: fixed a bug which gave weird results if hi- _and_
1335 lo-gain could not be extracted properly. In some cases hi-
1336 and lo-gain have not been extracted at all and the random result
1337 got calibrated. In other cases the hi-gain was saturating and the
1338 lo-gain has not been extracted. For this a completly arbitraty
1339 scale factor was applied to the result from extracting the
1340 charge of the saturating hi-gain.
1341
1342 - callisto: improves handling of extracted signal if lo- and/or
1343 hi-gain could not be extracted properly. If no appropriate
1344 calibration of either the signal or the arrival time is possible
1345 the pixel is now markes as unsuitable instead of estimated.
1346
1347 - callisto: Fixed a problem in the spline extraction which gave
1348 weird results if the signal was extracted from the first (and
1349 highest) slice (as a workaround extraction from the first
1350 slice has been forbidden)
1351
1352 - callisto: Fixed a bug regarding the use of the QE which doesn't
1353 effect the result because the default is used anyhow.
1354 (The bug was there since 14/07/2005)
1355
1356 - callisto: Changed the default for fgLoGainStartShift to -2.4
1357
1358 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1359 factors to be always 10 for all pixels as soon as the first
1360 calibration update has happend.
1361
1362 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1363 was off by more than one slice (which gives wrong values for
1364 pixels which have saturated the hi-gain) This was a problem
1365 mainly for timing studies, not so much for the automatic standard
1366 analysis. Also the values for the Spline have been changed slightly:
1367 + Digital Filter from 1.70 to 0.95
1368 + Spline from 1.39 to 1.30
1369 The numbers were sorted out by an extensive test in the
1370 test-database.
1371
1372 - callisto: Removed the tab showing the average calibrated arrival
1373 time. It never gave useful information.
1374
1375 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1376 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1377 and both were extracted because the hi-gain was above the
1378 LoGainSwitch.
1379
1380 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1381 lo-gain pulse position (after application of LoGainOffset, which
1382 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1383 have saturated and both were extracted because the hi-gain was above
1384 the LoGainSwitch.
1385
1386 - callisto: After extensive tests a new threshold level for determination
1387 of the pulse position has been found at 50phe. This is due to the
1388 fact that for lower pulses the arrival time changes its average
1389 behaviour dramatically. It tends to the average of the extraction
1390 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1391
1392 - callisto: Added two more plots to the calibration part. The average
1393 extracted signal and the average extracted arrival time as
1394 extracted by the signal extractor (This can help debugging problems
1395 because it doesn't involve a fit)
1396
1397 - star: changed the fit for the effective on time such that initial
1398 values are calculated automatically now instead of using build
1399 in values. This makes the fit more indepedant of the underlaying
1400 rates. With a test of ~350 sequences in the test database it could
1401 be shown that the new fit gives the same result +/-1sek.
1402 The highest deviation was +5s the lowest -10s. You can now control
1403 the bahaviour with two resource values:
1404 MHEffectiveOnTime.FistBin: 3
1405 MHEffectiveOnTime.NumEvents: 12000
1406 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1407 from the resulting gamma candidates
1408
1409 - star: The Center histogram in MHHillas is now by default displayed
1410 with the colz draw-option
1411
1412 - ganymed: now produces valid error codes if failed
1413
1414 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1415 with the option "hadronness" instead of "area" or "both" if
1416 you want to use both cuts. The hadronness cut includes a fixed
1417 cut in hadronness (index 8) and a fixed cut in size (index 9).
1418
1419 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1420 the M3Long of the anti source to be not properly evaluated
1421 (actually is was evaluated as a unique random number) in case
1422 of optimization with anti-theta cut switched on. This might have
1423 lead to improper, but not necessarily wrong, optimization results.
1424
1425 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1426 how to use random forest
1427
1428 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1429 ganymed_onoff.rc. Seems to be unintentional that they were different.
1430
1431 - sponde: Since the introduction of the possibility to define a
1432 normalization energy instead of using the integral the default
1433 was not using the integral anymore but a normalization energy of
1434 1GeV. It is now the integral again.
1435
1436 - sponde: Fixed a problem in the weighting which did not allow
1437 a MC slope of -1.
1438
1439
1440
1441 *** Version 0.9.6 (2006/05/24)
1442
1443 - general: changed the binning of the azimuthal profile of the camera
1444 such that it is aligned with the 60deg boundaries.
1445
1446 - merpp: better handling of problems with the TH, TD part of the
1447 CC-REPORT for files older than 200507190 and 200412210
1448 respectively
1449
1450 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1451
1452 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1453
1454 - callisto: if an arrival time is extracted outside the fadc range is
1455 was set to the boundary before. Now a random number is assigned
1456 instead to avoid unfortunate coincidences of arrival times just
1457 by this arbitrary value.
1458
1459 - callisto: added a new option to callisto.rc which allows
1460 to set the maximum arrival time difference allowed for the
1461 badpixel algorithm to determin whether a pixels belongs to a shower:
1462 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1463
1464 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1465 to 0.9 as suggested by Stefan due to a recent study on the fraction
1466 of pixels surviving the image cleaning
1467
1468 - callisto: switched off error in case of "pulse is too much to the left"
1469
1470 - callisto: The extraction window is not adapted anymore. This means that
1471 the pulse is extracted from the full range. The draw-back is that the
1472 background (pedestal) will become slightly higher. Switching on/off
1473 the PulsePosCheck in the callisto.rc only effects filling the
1474 histograms.
1475 WARNING: If the pulse is too much to the left data is calibrated!
1476 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1477 in the database to make sure that your data is valid!
1478
1479 - star: Show also the number of stars correlated correctly by the
1480 starguider
1481
1482 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1483 than one off-source region in wobble-mode. To use it add the following to
1484 your ganymed_wobble.rc:
1485 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1486 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1487 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1488 + Cut1.ThetaCut: None
1489 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1490
1491 - ganymed: in the case the latest report is older than a default (currently
1492 one minute) and the current report will be skip the starguider
1493 correction and calibration will be reset. The maximum age can be
1494 setup from ganymed.rc by (minutes):
1495 MPointingDevCalc.MaxAge: 1.5
1496
1497 - ganymed: A first implementation showing all size-bins for the theta-sq
1498 resp. alpha-plots in a single tab automatically
1499
1500
1501
1502 *** Version 0.9.5.1 (2006/05/05)
1503
1504 - general: Added a new option "zdiff" to the Makefile which runs
1505 "cvs diff" as "make diff" would do, but with compression
1506
1507 - general: accelerated MTFillMatrix (used for eample in all training
1508 and optimization macros) by skipping some obsolete calles in the
1509 eventloop the first and second loop could be accelerated by ~20%
1510
1511 - general: Added a missing feature in the MFilterList class which
1512 prevented MFEnergySlope from working correctly in trainenergy.C
1513
1514 - general: Accelerated the random forest training and usage a bit
1515
1516 - merpp: Adapted to new raw data file format version 6
1517
1518 - merpp: fixed a problem with reading the starguider reports
1519 after 6.3.2006
1520
1521 - callisto: At some times six pixels had to be exchanged manually in the
1522 data. If the pixels to be swaped are both not found, an error was raised
1523 and calibration was stopped. Now it is assumed they are intentially not
1524 mapped and the Error has been changed to a Warning.
1525
1526 - star: Added new image cleaning based on the arrival time of the shower.
1527 The new cleaning can be accessed using the parameter "Time" instead of
1528 the the old one (like "Absolute) in the star.rc-file.
1529 Recommended parameters:
1530 + MImgCleanStd.CleanLevel1: 8.2
1531 + MImgCleanStd.CleanLevel2: 5
1532 + MImgCleanStd.CleanRings: 2
1533 + MImgCleanStd.KeepSinglePixels: No
1534
1535 - star: Simplified the calculation of the effective on time. By letting
1536 the fit start in the third bin the result should become more stable.
1537 The fit quality is now ignored for the theta-plot which is not used
1538 in the analysis later. Still better pre-cut which, for example,
1539 remove events triggered by car-light (rate changing on a short
1540 time-scale) are missing.
1541
1542 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1543 for optimization (kWeakSource) which is suggested by the Berlin
1544 people for weak sources.
1545
1546 - macros: plotdb.C:
1547 + if no dataset and no time-interval is given only sequences with
1548 an effective on-time above five minutes are plotted anymore
1549 + added a new tab "RelTime" displaying the relative on-time
1550 (effective on-time divided by the observation time)
1551
1552 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1553 the optimization became a lot faster
1554
1555 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1556 To display them just delete the pads displayed on top.
1557
1558 - ganymed: fixed a bug which could cause strange behaviour in wobble
1559 mode if no starguider information was available due to an incorrect
1560 initialization of the starguider calibration
1561
1562 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1563 be changed from within the plot. It can also be setup from the
1564 resource file using:
1565 + MHDisp.fScaleMin: 0.325
1566 + MHDisp.fScaleMax: 0.475
1567
1568 - ganymed, showplot: Fixed a problem with the fit to the off-data
1569 (HistOff) which could cause a time lag or an inifinite loop.
1570 The bug did not effect the results at all.
1571
1572 - sponde: Added a new tab showing the effective collection area after
1573 trigger (including the software trigger)
1574
1575 - sponde: MMcSpectrumWeight has a new option which allows to define
1576 the scaling factor not by the integral of the events but at
1577 a defined energy:
1578 e.g. MMcSpectrumWeight.NormEnergy: 200
1579
1580 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1581 eventloops the loop could be accelerated by ~20%
1582
1583
1584
1585 *** Version 0.9.5 (2006/03/13)
1586
1587 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1588 and added the standard Disp-parametrization
1589
1590 - macros: added a new macro datacenter/macros/plotstat.C allowing
1591 to plot statistics about the data processing
1592
1593 - macros: added a new macro to plot the muon correction coefficients
1594 versus period (macros/plot/mucal.C)
1595
1596 - showplot: path inflation for ganymed files was broken
1597
1598 - callisto: Fixed an important bug. When the number of saturating pixels
1599 were calculated the bad pixel information already available from the
1600 calibration was ignored. This yields wrong values in case pixels
1601 are broken and saturate all the time or randomly.
1602
1603 - callisto: Updated Muon calibration constants. Spline data now also uses
1604 different values for different periods
1605
1606 - star: The time-evolution shown in the effective on-time plot now displays
1607 the axis range (if there are no holes it should be similar to the
1608 effective on-time)
1609
1610 - star: Added two new image parameters:
1611 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1612 the three pixels next to the center of gravity and the size
1613 + MNewImagePar.fConcCore: The ratio of the signals of all
1614 pixels inside or touching the ellipse and the size
1615
1616 - ganymed: now stops in requested source isn't found in catalog file
1617
1618 - ganymed: Many improvements to the phi-plot in wobble mode:
1619 + with a template the ideal background is displayed
1620 + a possible camera inhomogeneity is taken into account
1621 + the anti theta cut is better supported
1622 + the phi cut is automatically calculated from the theta cut
1623 See the examples in ganymed_wobble.rc for more details.
1624
1625 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1626 times the bin-width instead of the absolute energy
1627
1628 - ganymed: New cuts for on/off and wobble mode
1629
1630 - ganymed: The smearing of the False Source plot has been increased
1631 to 0.06
1632
1633 - ganymed: The starguider calibration can now be changed from the
1634 resource file.
1635 See the examples in ganymed*.rc for more details.
1636
1637 - ganymed: added a new option for on-/off-observations
1638 MJCut.RandomSourcePosition
1639 If switched on the distribution of observation time of the source
1640 position in the camera is calculated from the on-data and randomly
1641 applied with this distrbution to the off-data.
1642
1643 - ganymed: by skipping some obsolete calles in the eventloop the
1644 first and second loop could be accelerated by ~20%
1645
1646 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1647 position in the off-data randomly according to its distribution in the
1648 on-data.
1649
1650
1651
1652 *** Version 0.9.4.3 (2006/02/13)
1653
1654 - general: Fixed a bug in most of the programs which prevented the
1655 compile date in the startup message to be displayed
1656
1657 - general: Simplified program calls. The following abbreviations
1658 are now possible:
1659 showlog callisto 55599
1660 showplot signal 55599
1661 star 55599
1662 callisto 55999
1663 ganymed 2
1664 In this cases the corrsponding root-, log-, sequence- or dataset-
1665 filename is automatically compiled using the default datacenter
1666 paths ("/magic/*")
1667
1668 - general: Fixed a long outstanding bug which made axis tick marks
1669 disappear if MDataFormula was used (eg. abs(x))
1670
1671 - general: Updated MMath with new functions to calculate the results of
1672 a exponential, logarithmic and powerlaw fits analytically.
1673
1674 - general: Updated some macros with comments:
1675 + macros/optim/optimdisp.C
1676 + macros/optim/optimenergy.C
1677 + macros/optim/optimwobble.C:
1678
1679 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1680 files) now allows adding a pre-cut like in the optimization. E.g. this
1681 is useful to perform g/h-separation cuts before training the random
1682 forest.
1683
1684 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1685 correctly assigned in the raw data assignement table. A fix to correct
1686 the assignment tabel have been implemented.
1687
1688 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1689 by 90, 180 and 270 deg.
1690
1691 - general: the macro plotdb.C now allows to highlight sequences belonging
1692 to a datset. For more details see the descritions in the macro.
1693
1694 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1695 of the display, it gave wrong results espacially for big sizes.
1696 Now the embedded canvas should always have a ratio width/height=3/2.
1697 The "Size" options have been updated with values fitting the 3/2
1698 size ratio.
1699
1700 - RanForest:
1701 + Updated the random forest classes to support also the
1702 regression method implemented by Thomas H.
1703 + added new tutorial macro how to train the random forest
1704 for energy estimation (macros/optim/rfenergyest.C)
1705 + new classes to train the random forest (still in development)
1706 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1707 + new tutorial macros for random forest training in macros/train
1708 trainenergy.C, traindisp.C, trainseparation.C
1709
1710 - mars: now allows to setup a cut in the resource file mars.rc to choose
1711 the events to be displayed, eg:
1712 Cut.Condition: {0} && {1}
1713 Cut.0: MHillas.fSize>100
1714 Cut.1: MHillas.fSize<900
1715
1716 - merpp: Made aware of the new .rep format 200510250. This includes
1717 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1718 the discriminator thresholds (MCameraTD) and the disciminator
1719 delays (MCameraTD). All of them come with the CC report and are therefor
1720 written to the CC tree.
1721
1722 - callisto: fixed a bug in the calculation of the arrival times in
1723 the Digital Filter. They were all shifted by the same amount
1724 fHiGainFirst. This caused an offset in the order of the position of
1725 the left border of the extraction window in the times calculated
1726 from high-gain and from low-gain. The bug effected only the absolute
1727 arrival times. The bug was there since 30.1.2005.
1728
1729 - callisto: Changed the ExtractionWindow for the pulse position check
1730 such that the camera inhomogeneity becomes as less as possible and
1731 comparable to the pulso position check switched off. More details
1732 on the study will be given at our result web-page.
1733
1734 - ganymed: ganymed.rc, ganymed_onoff.rc:
1735 changed to new cuts trained with 1ES1218 and Crab-data
1736 for maximum sigma*log10(excess)
1737
1738 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1739 a new option was implemented to estimate Disp (CalcDisp)
1740
1741 - ganymed: Implemented two new options which allow
1742 to overwrite the default path to search for the sequence files
1743 --ins=/magic/sequences
1744 and where to search for the image data
1745 --ind=/magic/data/star
1746
1747 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1748 dx/dy from the resource file by
1749 MSrcPosCorrect.Dx
1750 MSrcPosCorrect.Dy
1751
1752 - ganymed: fixed reading the source catalog. Only as many chars
1753 as the requested source name had were compared (If a source
1754 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1755 were requested it could happen that the coordinates of
1756 "1ES1218" were read) The source coordinates are now printed
1757 in addition to its name to the logging output.
1758
1759 - ganymed: changed the background fit in the case of a ThetaSq function
1760 from a polynomial to a exponential, this should give a big improvement
1761 for on-only analysis'
1762
1763 - ganymed/sponde: Calculation of the error of single size-/energy-
1764 bins now uses Li/Ma (5) instead of LiMa (17)
1765
1766 - sponde: Added a plot E^2*dN/dE
1767
1768 - sponde: The energy estimator plot should now show values like
1769 they are commonly used.
1770
1771 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1772 (a powerlaw with cutoff didn't work before)
1773
1774
1775
1776 *** Version 0.9.4.2 (2005/10/01)
1777
1778 - general: added new tutorial macro macros/tutorials/threshold.C:
1779 how to calculate the threshold
1780
1781 - general: added a new game. Start it from the interpreter with
1782 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1783 and MagicReversi)
1784
1785 - general: neighbor pixels in MGeoms are now sorted clockwise
1786
1787 - merpp: made aware of new format 20050829-0
1788
1789 - callisto: New scale factors from muon analysis, stored in new
1790 resource file resources/calibration.rc
1791
1792 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1793 the eventloop if something went wrong. This is necessary for the
1794 automatic processing
1795
1796 - callisto: Implemented a new treatment for the time information
1797 developed by S.Ruegamer, this should give much better response than
1798 the old very primitive algorithm. This is especially important
1799 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1800 treatment was buggy! As neighbor pixels to interpolate the
1801 arrival times always the pixels 0 to 5 were taken)
1802
1803 - callisto: In addition to the new treatment of arrival times the
1804 decision of the treatment whether a pixel contains shower
1805 information or not is used to improve the signal interpolation
1806 further. Previously interpolated pixels showed a non-zero signal
1807 do the peak searching signal extractors. Having a signal pixel
1808 beside raised the signal above the cleaning level. Thus the
1809 pixel survived cleaning to often but with a too low mean signal.
1810 By replacing empty pixels with a gaus (mean and rms from the
1811 corresponding Area entries in MPedPhotCam) this effect can
1812 be supressed.
1813
1814 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1815 got lost when the events were stored by the calibration... fixed.
1816 (This was no problem for normal image cleaning because the pixel
1817 content was artificially set to 0 not surviving standard cleaning
1818 algorithm)
1819
1820 - callisto: Fixed a bug which caused the random and peak-search pedestal
1821 extracted with an extractor to be exchanged for the first (roughly)
1822 500 events (*Extractor and *ExtractorRndm).
1823 (They were simply exchanged in callisto.cc) This bug might have been
1824 introduced in Mars 0.9.4 when the order of calculation of the two
1825 types of pedestal in callisto got exchanged. The bug only effects
1826 the first seconds of data of each sequence.
1827
1828 - star: Taking the arrival time of Muons into account the calculation
1829 of the parameters could be made independant of the noise
1830 (pedestal rms). The dependance was due to the bias of the peak search
1831 extractor. Now only a ZA dependamcy is left which is not yet fully
1832 understood.
1833
1834 - ganymed: The sequences were still not sorted correctly in any case,
1835 because they were sorted by the full qualified path name. Now they
1836 are sorted by their sequence number.
1837
1838 - ganymed: new values for the spark-event-cut
1839
1840 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1841
1842
1843
1844 *** Version 0.9.4.1 (2005/08/18)
1845
1846 - callisto: fixed some problems with the calibration in case of
1847 inteleaved events. Therefor the final and some intermediate
1848 fits are skipped which would take place on partly filled #
1849 histograms and gave wrong results or failed completely.
1850
1851 - callisto: If the intermediate finalization of the histograms
1852 calculating the mean charge of the calibration signal fails
1853 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1854
1855 - ganymed: Fixed some bugs which caused problems in On-only mode.
1856 Still the false source plot doesn't give reasonable results.
1857
1858
1859
1860 *** Version 0.9.4 (2005/08/05)
1861
1862 - general: Fixed the ZA binning. It did not correctly fit the
1863 MC binning
1864
1865 - general: Added a class to correct for the missfocussing in
1866 April (MSrcPosCorrect)
1867
1868 - general: Random Forest energy estimator should now work properly
1869
1870 - general: MHCamera now displays the profiles in deg instead of mm
1871
1872 - general: MH::SetPalette offers a lot of new palettes
1873
1874 - general: MHillas - the case of CorrXY==0 is now handled properly
1875
1876 - general: implemented the possibility to change the line and
1877 marker style of a sky-grid drawn by MAstroCatalog
1878
1879 - general: Runs in sequences and datasets are now automatically
1880 ordered (it is assumed that the order of their filenames correctly
1881 represents the order of observations) to ensure correct reading
1882 of the subsystem data
1883
1884 - general: Runs cannot be added to a sequence twice anymore. Also
1885 Sequences cannot be added twice anymore to a dataset.
1886
1887 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1888 It gave wrong results by 1./2pi
1889
1890 - showplot: got a new option to start a root interpreter, too
1891
1892 - mars: now displays a rough estimate of Disp and the third moment
1893
1894 - mars: now displays the event time MTime if available
1895
1896 - mars: show muon parameters graphically
1897
1898 - mars: now the file to open can be given as commandline
1899 argument
1900
1901 - merpp: Added support for new arehucas version >= 200507190
1902 implementing values for three temperature sensors in the
1903 counting house (MCameraAUX) and the name of the HV settings file
1904 (MCameraHV).
1905
1906 - merrp: Also fixed some problems with wrong versions numbers stated
1907 by arehucas and implemented some fixed for old versions (<200407070)
1908
1909 - callisto: MCalibrationHiLoCam can now be printed from its context
1910 menu, eg in the TBrowser
1911
1912 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1913 - 1.39 (MExtractTimeAndChargeSpline)
1914 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1915 This is important mainly for timing studies.
1916
1917 - callisto: Changed limits in MHCalibrationChargeCalc from
1918 - -100.125 to -98 (fgChargeHiGainFirst)
1919 - 1899.875 to 1902. (fgChargeHiGainLast)
1920 - -100.25 to -99 (fgChargeLoGainFirst)
1921 - 899.75 to 901. (fgChargeLoGainLast)
1922 Introduced new limits:
1923 - fgNumLoGainBlackoutLimit: 0.05
1924 - fgLoGainBlackoutLimit: 3.5
1925 - fgLoGainPickupLimit: 3.5
1926
1927 - callisto: The handling of automatic weights for the digital filter
1928 has been improved. There are now new calibration weights special
1929 for Monte Carlo calibrations.
1930
1931 - callisto: Updated Muon scale with latest results (1% difference
1932 for most data, 5% for Mar/Apr'05)
1933
1934 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1935 was saturated and the blackout-events in the low-gain exceed the
1936 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1937 This excludes those pixels which have a saturating high-gain
1938 channel, but the low-gain switch does not switch often enough
1939 to make the distribution reliable.
1940
1941 - callisto: fix a bug counting the number of saturated events. Up to now,
1942 the number of saturated slices was counted (which is one for a not too
1943 high number), but for some (pathological) pixels, many more slices
1944 saturated and produced wrong limits.
1945
1946 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1947 + MCalibrationRelTimeCam.CheckFitResults: Yes
1948 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1949 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1950 + MCalibrationRelTimeCam.CheckOscillations: Yes
1951
1952 - callisto: introduce max. number of events for intercalibration,
1953 the rest gets skipped. Default: 4096
1954 The calibration causes too many un-reliable pixels if more
1955 than about 5000 events are treated (@500 Hz) because of the
1956 mode hopping of the VCSels. However, in the past, some
1957 calibration runs have been taken (erroneously) with more
1958 than 5000 events, especially the intensity scans where
1959 a good precision is needed.
1960
1961 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1962 photo-electrons for the spline extractor by 1-2% (correctly).
1963
1964 - callisto: The intercalibration is now done using a full f-factor
1965 method instead of a simple update. This makes things slower but
1966 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1967 changes.
1968
1969 - callisto: MPedestalY3 now uses the same extraction range as the data
1970 as calculated by MPedestalY2
1971
1972 - callisto: A check of the fraction of allowed unsuitable (10%) and
1973 unreliable (30%) pixels has been addded when the conversion is
1974 calculated from interleaved events
1975
1976 - star: fixed a bug which caused MEffectiveOnTime containers not to
1977 be written. In the worst case they were skipped almost all, in the
1978 best case they were all ok. It depends on how often the new value
1979 was assigned just with an event which was skipped later by another
1980 task
1981
1982 - star: new histograms MHPointing and MHRate
1983
1984 - star: New tab (Currents) displaying the time evolution of the mean
1985 DC currents
1986
1987 - star: New tab (MeanRms) displaying the time volution of the mean
1988 Pedestal Rms
1989
1990 - star: Output now contains MReportStarguider
1991
1992 - star: Improved muon analysis. Due to the absense of a constant
1993 for the gaus fit for arc width and the fact that the arcwidth
1994 plot was a histogram instead of a profile the resulting psf
1995 became pedestal rms dependant
1996
1997 - ganymed: added new plot (MHPhi) for wobble mode as described in
1998 http://www.astro.uni-wuerzburg.de/results/ringmethod/
1999
2000 - ganymed: corrects now (correctly?) for the misspointing in
2001 May/April 05
2002
2003 - ganymed: Two new default templates for ganymed.rc are avilable:
2004 ganymed_onoff.rc and ganymed_wobble.rc
2005
2006 - ganymed: The first version of MFMagicCuts has been released
2007
2008 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2009
2010 - ganymed, sponde: There are two new options to determin the number
2011 of bins for the signal region (NumBinsSignal) and the number of
2012 total bins (NumBinsTotal) in the MHThetaSq histogram
2013
2014 - ganymed: optimized palettes for MHDisp
2015
2016 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2017 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2018 sqrt(2) to large
2019
2020 - ganymed: The false source plot (MHDisp) is now based on Disp
2021 and a background model determined in the first loop is
2022 subtracted
2023
2024 - ganymed: MFMagicCuts are now available in the cvs. The correct
2025 solution for the disp ambiguity problem is now calculated using
2026 the third moment. The third moment cut therefor is skipped.
2027
2028 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2029 already determined by the third moment along the major axis and
2030 so its actual sign is aligned along the major axis of the shower.
2031
2032 - ganymed: If starguider data is available it is taken into account
2033 when calculating the source position. This is especially important
2034 for wobble data at high zenith angles and culmination data.
2035
2036 - ganymed: If available the starguider data is taken into account as
2037 good as it is possible without a starguider calibration. To switch
2038 it off add
2039 MPointingDevCalc.MaxAbsDev: -1
2040 to your ganymed.rc
2041
2042 - sponde: the zenith angle distribution is now weighted instead of
2043 choosen by default. This gurantees higher statistics in the highest
2044 and lowest energy bins. To switch this behaviour off use...
2045
2046 - sponde: now automatically displays the energy threshold
2047
2048
2049
2050 *** Version 0.9.3 (2005/06/03)
2051
2052 - general: MMcEvt now derived from MMcEvtBasic which should
2053 have no influence on compatibility with older camera files
2054
2055 - general: Implemented a new option to MReadReports which allows
2056 to force reading of the first event of some trees (eg. Drive-tree)
2057 before any other tree.
2058
2059 - general: Made a fix to MPointingPosCalc which assumes that the
2060 run-type is real-data if Process is called before ReInit, such
2061 that also the very first Drive-events in a run are treated
2062 correctly.
2063
2064 - shoplot now displays the filename in the title bar of the window
2065
2066 - merpp: new options: --auto-time-start --auto-time-stop which
2067 allow to cut updating with slow-control at the start- or
2068 (previousle --auto-time only allowed: and) stop-time of
2069 the run stored in the runheader.
2070
2071 - callisto: changed default of fgFallTimeHiGain in
2072 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2073 already set as default in callisto_Dec04Jan05.rc
2074
2075 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2076 now changes the filename for new weights automatically for
2077 cosmics, MC and for different calibration colors.
2078
2079 - callisto: a problem with the order of some code cause the
2080 name of the weights file in MPedestalY2 to be ignored.
2081 Wrongly the calibration_UV weights were used instead
2082 of the cosmics weights set in callisto.rc.
2083
2084 - callisto: should allow ct1 pulser data when the color is
2085 explicitly set also for pretty new runs
2086
2087 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2088 to introduce an additional scale factor (should be around 1)
2089 to adapt for slight deviations in different extractors from
2090 the MC calibration. For MC calibrations the scale factor
2091 is fixed to 1
2092
2093 - callisto: MFCosmics should handle very high signals a bit
2094 more accurate now
2095
2096 - callisto: when calculating the mean pedestal rms for different
2097 pixel sizes or sectors also kUnsuitableEvt is now taken into
2098 account - not only kUnsuitableRun
2099
2100 - callisto: '-raw' option is now the default
2101
2102 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2103 This has the advantage that mean values in the calibration (eg
2104 arrival times) are calculated more accuratly.
2105
2106 - callisto: In the resource file callisto_Dec04Jan05.rc
2107 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2108
2109 - callisto: new Hi-/Lo-Gain intercalibration constants
2110 hilocalib_sp1.root and hilocalib_sp1_mc.root
2111
2112 - callisto: changed default for MJPedestalY2.MaxEvents
2113 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2114
2115 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2116 has changed from 9.0 to 6.0. This is necessary to exclude two very
2117 ringing pixels in September which - when kept - destroy the image
2118 cleaning around them (Markus G.)
2119
2120 - callisto: (!) The Muon analysis of all data taken so far has
2121 suggested that different extractors give slightly different
2122 absolute results after calibration, due to there different
2123 handling of the calibration- and cosmics pulse shape. Although
2124 the over all calibration seems to be a bit to pesimistic (or
2125 the MC seems to be a little bit - 3-5% - too much attenuated).
2126 There for correction factors have been introduced which correct
2127 the calibration constants by
2128 0.956937799 for Digital Filter (callisto.rc)
2129 and
2130 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2131 calibration. The main advantage is, that both data types can
2132 be easily analysed together and compared to the same MC sample.
2133 The factors are choosen such, that the reference is now a
2134 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2135
2136 - star: fixed a bug which caused the first bin of the histograms
2137 vs time to disapear in PostProcess. This gave wrong results
2138 on the screen. The output and all following programs not
2139 directly accessing the histograms haven't been affected
2140
2141 - star, ganymed: Made sure that always the first Drive-tree event
2142 is read and Processed before the first data event was read.
2143
2144 - ganymed: implemented the possibility to replace the standard
2145 false source plot with a different one. For example: If
2146 you want to use a Disp based FS plot use the resource:
2147 NameHistFS: MHDisp
2148 For details about the requirements of these plots look
2149 at the corresponding classes
2150
2151 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2152 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2153 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2154 case MAlphaFitter is setup correctly. For On-Only optimization
2155 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2156 RunOn() instead of Run(). For energy estimation MJOptimize
2157 has been replaced by MJOptimizeEnergy
2158
2159 - sponde: The input MC spectrum can now be weighted to fake a
2160 different spectrum. This is done via MMcSpectrumWeight. For
2161 more details see the class description and sponde.rc
2162
2163 - sponde: The paremeter comparsion plots are not scaled by
2164 their entries anymore. Instead the MC plot is scaled by using
2165 the result spectrum of the analysis. If the input MC spectrum
2166 and the result spectrum has different slopes the absolut
2167 normalization is normally wrong.
2168
2169
2170
2171 *** Version 0.9.2 (2005/05/20)
2172
2173 - general: Changed the default paths for calibrated data and image
2174 files. (The implemented access to these files doesn't yet exist)
2175
2176 - general: support for MRunIter has been removed from the job classes
2177 (use the setter functions of MSeqeunce instead)
2178
2179 - general: ProcessFile has been renamed to Process in all job classes,
2180 because ProcessFile is missleading
2181
2182 - general: The storage of the palette in MHCamera is now possible
2183
2184 - general: new bits describing unsuitable and unreliable pixels have
2185 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2186 kDeadPedestalRms, kFluctuatingArrivalTimes
2187
2188 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2189 versions newer than V200404070
2190
2191 - general: support for cc file versions newer than V200504130. Added
2192 support for active loads (MCameraActiveLoad) and central pixel
2193 (MCameraCentralPixel)
2194
2195 - general: added new histograms for image parameters versus size
2196 (MHVsSize)
2197
2198 - general: The eventloop now automatically calls PrintStatistics
2199
2200 - Status Display: Improved support for printing:
2201 + A default can now be set in .rootrc (for more details see
2202 MStatusDisplay::PrintPS)
2203 + A print dialog is opened so that printer and command line
2204 can be canged
2205
2206 - showlog: improved such that it handles different verbosity levels
2207 more accurate now. This mean you can suppress output when
2208 using showlog.
2209
2210 - showplot: improved
2211 + The new graphics formats have been implemented
2212 (pdf, svg, png, jpg and xpm)
2213 + Implemented an interface for printing. Because you can change
2214 the printing command from the command line you can use all
2215 the nice postscript tool. To print a booklet for example call:
2216 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2217 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2218 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2219
2220 - callisto: fixed a bug in the recognition of the calibration bit
2221 pattern. Concerns only intensity calibration. (The strength of the
2222 intensity has been updated in some cases)
2223
2224 - callisto: add a filter against PIN Diode events when running over
2225 calibration runs since some of the recent calibration runs have
2226 been taken with Pin Diode.
2227
2228 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2229 39943, 44833 in the calibration (MCalibColorSet)
2230
2231 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2232 been set to 1e-18 in callisto_Dec04_Jan05.rc
2233
2234 - callisto: in callisto_Dec04Jan05.rc: set value for
2235 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2236 statistics for the calculation of the mean pulse time
2237 of the cosmisc
2238
2239 - callisto: the charge limit in the calibration has been raised
2240 from 2.5 to 4.5
2241
2242 - callisto: new setup read from callisto.rc
2243 + MCalibCalcFromPast.fNumEventsDump
2244 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2245 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2246
2247 - callisto: MExtractTimeAndChargeSpline extractor:
2248 + The integration ranges were shifted by 0.2 FADC slices to the right.
2249 + unreliable handling of floating point values caused different
2250 results on different platform or with different compiler options:
2251 The new algorithm is numerically exact and more accurate because
2252 it doesn't calculate the integration position by multiple times
2253 adding the step-size (which results in numerical uncertanties
2254 exspecially if multiplied with large numbers)
2255 + A lot of fixes have been introduced which effects integrating the
2256 spline at the edges of the valid range. In this case any memory
2257 was randomly accessed. This behaviour can be tested replacing
2258 all MArrayF by TArrayF which perform a range check (but of course
2259 they are a lot slower)
2260 ! No result obtained with the Spline before can be trusted! Due to
2261 random memory access it might by completely random!
2262
2263 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2264 + extraction range in the high gain to 4.
2265 + weights file to cosmics_weights46.dat
2266
2267 - callisto:
2268 + introduce the check for fluctuating arrival times.
2269 + set charge limit to from 2.5 to 4.5
2270 + introduce asymmetric exclusion due to "deviating number of phes":
2271 Default: -9.0 +4.5
2272 + make deviating number of phes unsuitable (see David's findings).
2273
2274 - callisto: fixed the display of unsuitable pixels. The old change
2275 to a real profile in MHCamera broke it.
2276
2277 - callisto: The cosmics filter is used in MJCalibration now
2278 independant of the pulser color (formaly it was used only for
2279 CT1-pulser data). The threshold of number of max empty pixels
2280 has been raised from 2% to 5% in MJCalibration. The maximum
2281 fraction of rejected event is 50% otherwise the calibration has
2282 failed. The filter now ignores unsuitable pixels.
2283 Setup the filter from callisto.rc using "ContCosmics"
2284 (see MFCosmics::ReadEnv)
2285
2286 - callisto: changed default for fgOffsetFromLogain back
2287 from -2.8 to -1.8 in digital filter.
2288
2289 - callisto: for the common extractors
2290 + MExtractFixedWindow
2291 * MExtractTimeAndChargeSlidingWindow
2292 * MExtractTimeAndChargeSpline
2293 * MExtractTimeAndChargeDigitalFilter
2294 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2295 and fResolutionPerPheLoGain
2296
2297 - callisto: Updated the hi-/lo-gain intercalibration constants
2298 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2299 hilocalib_df6.root
2300
2301 - callisto: The default lo-gain extraction window for the
2302 MExtractTimeAndChargeSlidingWindow extractor has been increased
2303 from 6 to 8 to take the stretch of the pusle into account
2304
2305 - callisto (!!!): fixed an important bug in the setting of the
2306 incoming pedestal pointer to the signal extractor extracting
2307 pedestals. This bug caused the pedestals not to be subtracted
2308 correctly in the calibration afterwards. The effect was about 10%
2309 too high conversion factors for the digital filter and the spline
2310 and more than 40% for the sliding window.
2311 The bug existed since end of February! (Markus G.)
2312
2313 - star: added muon support to star. A new tab "MHMuonPar" is
2314 displayed. The lower right plot is an estimate of the point spread
2315 function. A reference value is displayed. To get the real PSF
2316 you must compare with MC. The setup for the muon analysis
2317 is done in star.rc. More informations can be found in
2318 MHSingleMuon and MHCalibParCalc
2319
2320 - star: The weather data is now displayed in star
2321
2322 - star: MEventRateCalc handles the calculation of the event rate more
2323 accurate now in case of the start of a new run inside a sequence
2324
2325 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2326 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2327 changed only minimally
2328
2329 - ganymed: (MJCut and MJOptimize) now displayes the number of
2330 excess events versus size. The energy estimation is done in
2331 MJSpectrum (sponde)
2332
2333 - ganymed: got support for using other variables than Alpha, eg. Theta.
2334 Therefor you need a class deriving from MHAlpha which supports
2335 this variable (one is already existing: MHTheta, which is now the
2336 default in ganymed). It is setup through ganymed.rc
2337
2338 - added a full featured spectrum program (sponde) which reads
2339 ganymed output and monte carlos and compiles a spectrum
2340
2341
2342
2343 *** Version 0.9.1 (2005/04/14)
2344
2345 - Fix bug on the arrival time reconstruction when using Digital
2346 Filter (in some marginal cases (10%) times were reconstructed shifted
2347 by 0.2 slices)
2348
2349 - all executables now return 2 where in previous versions -1 has
2350 been returned (gave problems with shell-scripts)
2351
2352 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2353 also done with a intercalibration input file
2354
2355 - a bug in the time fine adjustment of the digital filter has been fixed
2356
2357 - a lot of small fixes to calling TPad::Divide with a margin==0
2358
2359 - MStatusDisplay now shows the memory usage
2360
2361 - added a memory leak statistic after the eventloop
2362
2363 - MHadronness replaced by MParameterD
2364
2365 - MEnergyEst replaced by MParameterD
2366
2367 - wobble mode can now be switched on from the data-set
2368
2369 - switched on bad pixel detection for a pedestal level
2370 which is more than 5 times the variance
2371
2372 - Fixed default paths to be correct for the new data center
2373
2374 - Fixed handling of drive data. The pointing position in now
2375 copied to MPointingPos inside star for real and MC events
2376
2377 - made sure, that the sequences in a dataset are sorted by
2378 their number to ensure the correct synchronization
2379
2380 - added all resource files necessary to handle spline extraction
2381 of signal for the late 2004 and the early 2005 data
2382
2383 - update the reference lines for the december data
2384
2385 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2386 This is important for the Dec. and Jan. data where the calibration
2387 pulse position changes much.
2388
2389 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2390 filter. This corrects only an defective extraction of the MC at
2391 low-gain signals lower than 90 phes.
2392
2393 - fixed some slowdown in calibrating data with interleaved events from
2394 Jan and Dec. As a workaround made the pretty palette the default.
2395 The inverse Deep Blue Sea has a bug which slows down long calibration
2396 runs a lot.
2397
2398 - implemented new values from new starguider report as defined
2399 in TDAS00-07 V7.1 (eg SkyBrighness)
2400
2401 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2402 in starguider report (If you merpp the same reports with this version
2403 you'll get the correct units (arcmin) but a different result
2404 than with old versions (wrong units))
2405
2406 - Now the status display can also write PNG, JPEG and XPM (other file
2407 formats are still unsupported by root)
2408
2409 - added a lot of scripts and macros in directory datacenter used
2410 for automatic processing
2411
2412
2413
2414 *** Version 0.9 (2005/03/23)
2415
2416 - Calibration is now done autmatically into photo-electrons like
2417 decided by the Collaboration Board
2418
2419 - Reference lines in the display can be read from resource file
2420
2421 - Interlaced calibration events can be handled by callisto
2422
2423 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2424 and applied in callisto.
2425
2426 - class MJCalibTest can be called by callisto
2427
2428 - callisto can now run with three data types: rawdata, rootdata, MC
2429
2430 - added two classes mreport/MReportStarguider.cc and
2431 mreport/MReportStarguider.h for implementing starguider-data
2432
2433 - the output of merpp-update now contains starguider information:
2434 MReportStarguider and MTimeStarguider
2435
2436 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2437 values were lower than they should. This was more visible for high
2438 energy (Size) events.
2439
2440 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2441
2442 - added a new loop to callisto to support the correct extraction of
2443 the pedestal and pedestal rms through the signal extractor
2444
2445 - added class to perform fourier tranformation of a hexagonal structure
2446 (MHexagonalFT)
2447
2448 - added class to perform fourier tranformation of a hexagonal structure
2449 in a tasklist (MHexagonalFTCalc) example: hft.C
2450
2451 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2452 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2453 small pixels, example: extendcam.C
2454
2455 - added possibility to write data to memory (TTree) using MWriteRootFile
2456
2457 - added possibility to read a TTree stored only in memory by MReadTree
2458
2459 - new classes to deal with the interleaved calibration events:
2460 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2461
2462 - implemented filters to callisto to skip calibration events
2463
2464 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2465 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2466 the slices by statistics
2467 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2468 signal extractor without randomization
2469 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2470 with the signal extractor with randomization (extraction window is
2471 randomly fixed)
2472 The three kind of pedestal is not yet implemented (for speed reasons) as
2473 long as nobody really needs it:
2474 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2475 extracted with the signal extractor with randomization
2476
2477 - callisto now finds the pulse position in the data automatically
2478
2479 - implemented data reduction in calibrated data by reducing the precision
2480 of the stored floating point values (pedestal, rms and signal) to
2481 roughly 0.5%
2482
2483 - fixed showplot to make file format conversion (eg. converting a
2484 status display stored in a root file into a postscript file) in
2485 batch mode possible:
2486 showplot -b --save-as-ps[=outfile.ps] infile.root
2487
2488 - Allow class names as part of filter rules, eg
2489 (MFSupercuts) && (MHillas.fSize>100)
2490
2491 - fixed a lot of stuff to allow all programs to process MonteCarlo
2492 camera files.
2493
2494 - enhanced possibility to debug reading of resource file
2495
2496 - MDataChain should handle priorities of operator more
2497 accurate now
2498
2499 - completely revised the container in which the signal is stored
2500 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2501 * the new implementation is faster and
2502 * needs less storage space
2503
2504 - FIRST version which can process Monte Carlos through the
2505 whole chain of programs (callisto, star, etc)
2506
2507 - implemented new image parameters for the border length of
2508 the shower image (MNewImagePar2)
2509
2510 - implemented wobble-mode in ganymed
2511
2512 - new class (MJOptimize) taking care of all optimization processes
2513
2514
2515
2516 *** Version 0.8.6 (2004/10/05)
2517
2518 - New combined signal and time extractor
2519 MExtractTimeAndChargeDigitalFilter
2520
2521 - The Report for the trigger section in the CC run summary has been
2522 updated, and now the IPRs (Individual Pixel Rates) are available.
2523
2524 - new macros for database interaction: filldotrun.C, filldotrbk.C
2525
2526 - added new program which can convert colored output which was redirected
2527 into a file back into colored text (for example to display it with
2528 more): showlog
2529
2530 - added new program to display an MStatusArray of plots (stored with
2531 MStatusDisplay) from a file: showplot
2532
2533 - Added support for Sequences (MSequence). Sequences are blocks of run
2534 files containing the same calibration and belonging to the same
2535 source
2536
2537 - Added a new task (MTaskEnv) which can be used in setup files to switch
2538 between different tasks (for example to choose a signal extractor)
2539
2540 - Implemented automatic file splitting in MWriteRootFile
2541
2542 - After image cleaning an island index is assigned to all used pixels.
2543 The index corresponds to the order of the islands in size.
2544
2545 - added a cleaning which takes signal height _and_ arrival time into
2546 account: probability cleaning (for more details see MImgCleanStd)
2547
2548 - added a cleaning which takes takes the absolute number of photons
2549 times the area ratio as cleaning level
2550 (for more details see MImgCleanStd)
2551
2552 - Changed calculation of image parameters such, that it can be done
2553 for all used pixels or the pixels with a defined island index only
2554
2555 - implemented new image parameters displaying the number of islands,
2556 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2557
2558 - event display in executable changed to support also calibrated files
2559 (done with MJCalibrateSignal)
2560
2561 - added program doing the calibration and the signal extraction
2562 and signal calibration: callisto Most part of the setup is done
2563 by a resource file: callisto.rc
2564
2565 - implemented support for pixels with negative IDs (Raw file format
2566 version 4)
2567
2568 - implemented an new option in merpp (--auto-time) to get the time
2569 range for cc and/or caco data from the run header of the raw data
2570
2571 - New star-program (star and MJStar). Taking calibrated data from
2572 callisto/MJCalibrateSignal as input. The setup is done through
2573 a resource file: star.rc
2574
2575 - Added possibility to setup the eventloop in the mars-executable
2576 Camera Display by a resource file: mars.rc
2577
2578 - The the mars-executable Camera Display can now also read
2579 calibrated data files written by callisto/MJCalibrateSignal
2580
2581 - Added a new class which can calculate the source position in
2582 the camera from a pointing model known to be correct and
2583 the pointing model used for observations (MSrcPosFromModel)
2584
2585 - added a new version of the class calculating the effective on-time
2586 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2587 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2588 MHTimeDiffTheta.
2589
2590 - added the possibility to count how often a signal is above (or
2591 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2592 can replace MHTriggerLvl0)
2593
2594 - added ore convinient ways to set the axis-titles of your histograms
2595 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2596 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2597
2598
2599
2600 *** Version 0.8.5 (2004/08/06)
2601
2602 - new Signal Extractors: MExtractFixedWindowSpline
2603 and MExtractAmplitudeSpline
2604
2605 - implementes interleave in merpp to be able to merpp parts of a file
2606
2607 - implemented force-functionality to merpp
2608
2609 - star display to display star catalogs (MAstroCatalog)
2610
2611 - star display to 'mirror' stars to the camera (MAstroCamera)
2612
2613 - implemented a new cleaning option which allows cleaning scaled with
2614 the real ratio of the rms depending on the pixel size, not only the
2615 square root of the pixelsize (MImgCleanStd, MCameraData)
2616
2617 - removed obsolete MBlind* classes
2618
2619 - Signal extractor taking the AB flag into account implemented (this makes
2620 an odd number of slices for signal extraction possible
2621 (MExtractSignalABcorr)
2622
2623 - implemented a class extracting the pedestal from the raw-data (events)
2624 itself using empty lo-gain (MpedCalcFromLoGain)
2625
2626 - Added mean values to MPedPhotCam
2627
2628 - Added Makefile for Darwin (this OS is NOT officially supported!)
2629
2630
2631
2632 *** Version 0.8.4 (2004/04/19)
2633
2634 - new fast arrival time extractor using cubic splines:
2635 MExtractTimeFastSpline
2636
2637 - implementes multi-argument support in MDataChain
2638 ("pow(a, b)")
2639
2640 - implemented double reference support in MDataChain
2641 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2642
2643 - added support in MF for expressiond like
2644 "MHillas.fWidth<2*<MHillas.fLength"
2645
2646 - MDataChain is now able to support variables like [0], [1], ...
2647 which can be used in fit functions as parameters. The interface
2648 is implemented through the new virtual function
2649 MParContainer::SetVariables
2650
2651 - added new class MArrivalTimeCam/MArrivalTimePix:
2652 Storage containers to hold the ArrivalTime of the camera/pixel
2653
2654 - added new classes for the calibration of relative arrival times:
2655 MCalibrationRelTimePix and MCalibrationRelTimeCam
2656
2657 - added new classes to extract the signal of the blind pixel and the
2658 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2659
2660 - added new classes for the bad-pixels treatment (MBadPixels*)
2661 which are more powerfull than the old ones (MBlindPixel*)
2662 and will replace them.
2663
2664 - added filter against cosmics: MFCosmics
2665
2666 - added new class MArrivalTimeCalc2:
2667 Calculates the arrival time as the signal weighted mean of the time
2668 slices in the maximum window
2669
2670 - added a new macro call pointspreadfucntion.C that fits with a 2D
2671 gaussian the DC spot for an star. It gives you the RMS of
2672 the PSF and the center of the star, very useful for misspointing
2673 studies.
2674
2675 - added support for multi-telescope camera files. Added classes
2676 MStereoCalc and MStereoPar, classes to calculate and store shower
2677 parameters calculated from the data of two telescopes, for the MC
2678 studies regarding the MAGIC clone.
2679
2680 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2681 MC data calibrated in photons instead of ADC counts.
2682
2683 - added three macros to show the calibration and analysis chain of
2684 MC data. The macro starmc.C does both calibration and analysis, producing
2685 an output containing Hillas parameters for each event. The macro
2686 mccalibrate.C does just the calibration and writes out a file containing
2687 pixel information in photons instead of FADC data. The macro starmc2.C
2688 reads in such a file and produces an output with Hillas parameters.
2689
2690 - added MPedPhotCalc to compute pedestals in units of photons, see
2691 macro pedphotcalc.C
2692
2693 - added all class to perform the calibration, see macro calibration.C
2694
2695 - added class MFFT to perform Fast Fourier Transforms
2696
2697 - added class MSimulatedAnnealing to perform simulated annealing
2698 minimizations
2699
2700 - added new macro bootcampstandardanalysis.C which holds the skeleton
2701 of the analysis chain discussed in the december bootcamp.
2702
2703 - added support for DAQ raw data file format V2
2704
2705 - implemented an arbitrary time stamp for the events from raw-data
2706 files with file version<3. It is calculated from the run number,
2707 the date of start and the FADC clock tick from the first module
2708
2709 - implemented the correct decoding of the event time-stamp
2710 coming from the DAQ for raw-data files with file-version>2
2711
2712 - added a new classes storing the pedestals in units of photons:
2713 MPedPhotPix, MPedPhotCam
2714
2715 - added support for DC current files from the camera control
2716
2717 - added support for start- and stop-time when merpping report files
2718
2719 - added MReportCC storing the weather data from the CC-REPORT
2720
2721 - added class to fill trainings and test matrices (MTFillMatrix)
2722
2723 - added a filter performing a software trigger (MFSoftwareTrigger)
2724
2725 - Added classes to perform parts of the standard analysis (Jobs):
2726 + MJPedestals
2727 + MJCalibration
2728 + MJExtractSignal
2729 Note: All of them are preliminary!
2730
2731 - Added Iterator to iterate over files giving only the run-number
2732
2733 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2734 the evolution of a sector vs time
2735
2736
2737
2738 *** Version 0.8.3 (2003/12/05)
2739
2740 - adapted Random Forest classes to allow the use with MC
2741 multi-telescope files which can be produced with the coming
2742 camera version 0.7.
2743
2744 - added classes to read and interprete central control report files
2745 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2746
2747 - enhanced merpp (the executable) to support .raw and .rep files.
2748
2749 - added classes for light calibration (MCalibration* and
2750 MHCalibration*) by Markus Gaug. Further work has to be and will
2751 be done soon.
2752
2753 - Added a preliminary 'synchronizer' (MReadReports) which will
2754 replace MReadMarsFile as soon as it is finished.
2755
2756 - Added a tutorial macro demonstrating how report files are merpped
2757 and how they can be read from the root file in the correct order
2758 of time (readrep.C)
2759
2760 - Added a generalized histogram (similar to MH3) called MVsTime
2761 which allows to plot variables (or rules - MDataChain - of
2762 variables) vs time. For an example have a look at tempvstime.C.
2763
2764 - Changed the name of the event trees:
2765 + Events --> Events
2766 + PedEvents --> Pedestals
2767 + CalEvents --> Calibration
2768
2769 - changed name of MTime in the event trees from MRawEvtTime to MTime
2770
2771 - added displaying the sector indices to the mars event display
2772
2773 - Magic Online Analysis (MOnA) implemented in a first version
2774 (see mona.cc, MOnlineDump and MOnlineDisplay)
2775
2776 - added classes to calculate event rate
2777 (preliminary: MEventRateCalc, MEventRate)
2778
2779 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2780
2781 - added classes dealing with the telescope pointing position (MPointing*)
2782
2783 - implemented the 'final' Mars time stamp based on some experiences with
2784 the new 'Synchonizer'
2785
2786
2787
2788 *** Version 0.8.2 (2003/11/10)
2789
2790 - accelerated standard analysis by a factor of 6-8 ...
2791 + doing precalculations in MGeomCam for the pixel area ratio
2792 + creating a look up table for the single pixels in MCerPhotEvt
2793
2794 - added task to calculates weights in case you want to 'change'
2795 the energy spectrum of a monte carlo file
2796 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2797
2798 - added a new executable star which implements the
2799 star.C macro as precompiled executable. Currently a flexible
2800 setup is not possible, but a 'input card' setup will follow.
2801
2802 - Starting to implement Multi-Telescope-Support based on the
2803 upcomming camera version 0.7. The base for a general support
2804 is implemented and the star-functionality is proven to work.
2805
2806 - Replaced Event-Display in and Camera-Display in the Mars GUI
2807 executable by a more convinient display base on MStatusDisplay.
2808
2809 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2810
2811
2812
2813 *** Version 0.8.1 (2003/10/20)
2814
2815 - added signal subtraction for pure on data by means of fitting
2816 the background in the off region or by performing a combined
2817 signal/background fit. Provides necessary histograms for
2818 obtaining energy spectra and a light curve.
2819
2820 - added classes to perform and study the selection of the
2821 2nd Level Trigger on MC data (example in triglvl2.C macro)
2822
2823 - added pedestal calculation
2824
2825 - implemented "democratic cleaning" (tail cut value proportional
2826 to pixel area) according to Wolfgang's suggestion.
2827
2828 - added Sigmabar treatment (calculation and basic histogramming)
2829
2830 - added basic routines to apply padding
2831
2832 - added first implementation of MARS-based source visibility plotter
2833 (needs to be linked against slalib, preliminary version)
2834
2835 - enhanced functionality of data chains: random numbers, conversion
2836 functions and access to MHMatrix objects
2837
2838 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2839 numbers under certain circumstances (runs with 0 events included)
2840
2841 - fixed a bug in the general filter MF (didn't work on some systems
2842 at all)
2843
2844 - fixed a bug in chaining files, which caused the analysis to crash or
2845 ignore files
2846
2847 - implemented more geometry classes describing the parameters used
2848 to simulate the PMT camera
2849
2850 - added new Monte Carlo classes containing the setup of the different
2851 programs in the MC chain.
2852
2853 - added a (preliminary) general task to evaluate chi-square of a given
2854 parameter in an eventloop.
2855
2856 - first implementation of a container describing the observatory
2857 location (Long, Lat, etc)
2858
2859 - added Random Forest - method for g/h-separation
2860
2861 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2862 (this means, that it is compiling, but not yet fully tested)
2863
2864 - added a new status display which can show the present status
2865 of histograms while an eventloop is running (MStatusDisplay,
2866 an example can be found at status.C)
2867
2868 - reorganized directories:
2869 classes describing the image --> mimage
2870 classes containing Monte Carlo Histograms --> mhistmc
2871 classes for Random Forest method --> mranforest
2872
2873 - added (event-)weights to fill histograms
2874
2875 - colors in logging output to screen
2876
2877 - changes to the Image Parameter declaration:
2878 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2879 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2880 + MHillasExt now derives from MParContainer instead of MHillas
2881 --> Files written with the old definition are more or less unreadable
2882
2883 - reading of reflector files
2884
2885 - display data from reflector files in the camera
2886
2887 - implemented currents (and display them in the camera)
2888
2889 - logarithmic scale in camera
2890
2891 - added class to iterate through directory contents (MDirIter)
2892
2893
2894
2895 *** Version 0.8 (2002/11/18)
2896
2897 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2898
2899 - corrected 48(!) wrong entries in the Next Neighbor table of the
2900 Magic Camera (all in the inner part of the outer ring, mostly
2901 missing a single NN)
2902
2903 - Fixed a bug in the table describing the Next Neighbours of the
2904 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2905 have any neighbour)
2906
2907 - changed trigrate.C: now it calculates the pure NSB triggers from
2908 a camera file (generated with no showers), so there is no need
2909 to introduce them by hand in the BgR array (for more details
2910 please ask Abelardo)
2911
2912 - added MHHadronness (and MHadronness) as a general facility to evaluate
2913 the quality of a gamma-hadron seperation method
2914
2915 - changed MWriteAsciiFile to accept rules (MDataChain)
2916
2917 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2918 must be replaced by calles to MWriteAsciiFile::AddColumn and
2919 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2920 changed.
2921
2922 - Implemented generalized event-matrices (one row per event)
2923 (MHMatrix)
2924
2925 - implemented the one dimensional composite probabilities
2926 (MHCompProb, MCompProbCalc, comprob.C)
2927
2928 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2929 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2930
2931 - Added a camera display displaying the pixel numbers to the
2932 event display gui.
2933
2934 - Added Monte Carlo Informations to event display gui
2935
2936 - Changed the camera display to display the pixel numbering
2937
2938 - Added three buttons to the camera display to change the palette
2939
2940 - Added the number of used and core pixels after image cleaning
2941 to MHillas
2942
2943 - Changed the algorithm used in MHillas according to TDAS 02-03
2944
2945 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2946
2947 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2948
2949 - Added fCosDeltaAlpha to MHillasSrc
2950
2951 - The numbers of photons used to calculate fConc and fConc1 in
2952 MHillasExt are now scaled with the pixel size, so that one get
2953 a four times smaller value for the bigger pixels in the outer ring.
2954
2955 - added new task to smooth the camera contents (MCameraSmooth)
2956
2957 - added possibility to use interpolated pixel values for blind pixels
2958 instead of removing it completely from the analysis
2959
2960 - Implemented the possibility to save the whole eventloop with
2961 its setup to a file. This information can be read and from
2962 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2963 and MEvtLoop::MakeMacro. If you find something not working, please
2964 report - this stuff is still in a beta phase.
2965
2966 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2967 file having crab starfield, but also for all following files - fixed
2968
2969 - MTaskList::PrintStatistics can now be instructud to print also the
2970 title, too: use PrintStatistics(0, kTRUE)
2971
2972 - Changed the image cleaning so that pixels with to many 'used'
2973 neighbors are left used (to get rid of 'holes' in events)
2974
2975 - Introduced more output to the camera displays
2976
2977 - Added an array of histograms (eg one hist per run), MHArray
2978
2979 - Added a _preliminary_ version of the reader for CT1 PreProc files
2980 (MCT1ReadPreProc)
2981
2982 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2983 (thanks to Raquel)
2984
2985 - added the first energy estimator (MEnergyEstParam, estimate.C,
2986 estfit.C) using a parametrization
2987
2988 - Added some new Monte Carlo paremeter containers used to store
2989 setup information from the MC chain (MMcConfigRunHeader,
2990 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2991
2992
2993
2994 *** Version 0.7 (2002/04/30)
2995
2996 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2997 the pedestal mean value was saved incorrectly. For files from
2998 this versions we substract 0.5 from the pedestal mean.
2999 WARNING: This may effect your results, so don't wonder...
3000
3001 - First implementation of an algorithm using only triggered events
3002 for the collection area calculation
3003
3004 - Ascii Output can now also be used for parameter containers which
3005 doesn't overload MParCointainer::AsciiWrite
3006
3007 - The Ascii Output is now also capable of writing single data members
3008 of one container
3009
3010 - You are now able to change the order of the values written to the
3011 ascii file
3012
3013 - You can now specify a conversion factor for each data member written
3014 to an ascii file. This may be usefull to change the units of the
3015 data member (eg. degrees instead of millimeters in case of the
3016 hillas parameters)
3017
3018 - Replaced old MHillas by a new structure which allows you to extend
3019 the parameters stored in MHillas very easily:
3020 see MHillas and MHillasExt
3021
3022 - Added classes to handle source dependancy of image parameters:
3023 see MHillasSrc
3024
3025 - Added container (MBinning) to have a standard input for the binning
3026 in different histograms (eg. the Energy bins should be the same in
3027 all histograms)
3028
3029 - Changed Hillas histograms from mm to deg
3030
3031 - Added the flexible binning to the hillas histograms
3032
3033 - Added a filter for the alpha parameter (MFAlpha)
3034
3035 - It is now possible to write single data members of a class object to
3036 an output stream instead of the whole container only
3037
3038 - Added a generalized filter for a data member:
3039 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3040
3041 - Added a generalized Filter parser for more difficult filter rules
3042 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3043
3044 - Added new Monte Carlo histograms:
3045 MHMcEnergyImpact and MHMcEfficiency
3046
3047 - Added many new histograms needed for the flux calculation.
3048
3049 - Added a generalized histograms which can fill and show up to three
3050 data members in either a one-, two- or three-dimensional histogram, eg:
3051 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3052
3053 - Added:
3054 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3055 * calculation of <Theta> as a function of time (MHThetabarTime)
3056 they are needed in the flux calculation in
3057 order to select for a given bin in Theta (or time) the appropriate
3058 effective collection area, which is assumed to be given as a function
3059 of Theta and the true energy
3060
3061 - Added calculation of the migration matrix in the energy
3062 (MHMcEnergyMigration):
3063 the migration matrix describes the migration from the true (E_true)
3064 to the estimated energy (E_est); it is needed to determine the
3065 distribution of E_true from the measured distribution of E_est
3066 by unfolding
3067
3068 - changed the color palette in the camera display to DeapSea.
3069
3070
3071
3072 *** Version 0.6 (2002/01/15)
3073
3074 - Introduce the option of disable pixels (MBlindPixels and
3075 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3076 able to deal with Star Field NSB.
3077
3078 - Fixed a bug in the pedestals substraction
3079
3080 - Introduced verbosity levels
3081
3082 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3083
3084 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3085 work correctly (thanks to Abelardo)
3086
3087 - Introduced correct treatment of the diffuse Night Sky Background
3088 and NSB (MMcPedestalNSB)
3089
3090 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3091
3092 - Introduced MMcRunHeaders which contains monte carlo run informations
3093
3094 - Added a 'Print'-Task (MPrint) which calls the Print function
3095 of a parameter container for each event
3096
3097 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3098
3099 - changes to be more efficient with root 3.02/06
3100
3101 - root 3.02/06 fixes:
3102 + the memory leak when reading MRawEvtData
3103 + loosing more time than necessary to update the progress bar
3104
3105 - MWriteAsciiFile is now capable of writing more than one container
3106 in a line. For example: To be able to write Monte Carlo and
3107 Hillas values (energy and alpha) in one line.
3108
3109
3110
3111 *** Version 0.5 (2001/11/06)
3112
3113 - Added new GUI functionality (Analysis)
3114
3115 - Added a camera display to be able to display events in the camera
3116 together with the calculated hillas ellipse
3117
3118 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3119 object at any state of the analysis, so that the output are several
3120 states
3121
3122 - Fixed a bug in the collection area error calculation
3123 (Thanks to Ciro and Abelardo)
3124
3125 - Fixed a bug which causes merpp to crash in some environments
3126
3127 - Implemented auto enabling scheme for Branches to speed up reading
3128 a lot (see MReadTree and MTask)
3129
3130 - Fixed a bug in the Histogram classes which caused histograms to
3131 be written to a file by MWriteRootFile without request
3132
3133 - changed the object I/O from the old stylish root I/O to the new
3134 'auto evolution scheme' This was done only for classes which are not
3135 yet used in Monte Carlo files, so that these files are still readable.
3136
3137 - Added support for a progress bar in MEvtLoop and MReadTree
3138 (see the Analysis Window in Mars for an example)
3139
3140 - Fixed a bug in the package creation which disturbed the conversion
3141 between a mars version unpacked from a tar file and the repository.
3142
3143 - Changed the code to writer merpped (converted into root format)
3144 raw files, to get faster (around 10%)
3145
3146
3147
3148 *** Version 0.4 (2001/09/20)
3149
3150 - This release is made to compile on a root version >= 3.00
3151
3152 - Fixed a bug which causes MReadTree to read the first file only
3153
3154 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3155
3156 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3157
3158 - Added a task to write several container to a root file (MWriteRootFile)
3159
3160 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3161
3162 - Added calculation of the collection area (MMcCollectionAreaCalc)
3163
3164 - fixed some bugs in the Hillas calculation
3165
3166 - added filters to be able to control the task execution dependent on
3167 a parameter (for example: the number of level 1 triggers in a MC-file)
3168
3169
3170
3171 *** Version 0.3 (2001/04/23)
3172
3173 - Many demo macros added
3174
3175 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3176
3177 - Hillas Calculation added
3178
3179 - Standard image cleaning available
3180
3181 - MReadTree is now able to handle more than one file
3182 (Remark: of the same structure)
3183
3184 - Now we are able to display events in a first version of the
3185 Camera event display. To do this we must run the macro
3186 "macros/readCT1.C" to read data from CT1.
3187
3188
3189
3190 *** Version 0.2 (2001/01/24)
3191
3192 - First Implementation of a Gui to read the raw data. Start the
3193 gui with the command mars.
3194
3195
3196
3197 *** Version 0.1 (2000/12/20)
3198
3199 - First official release 0.1
3200
3201 - Changes:
3202
3203 + changed calling style of MRawPixelIterator from do...while to
3204 while-loop
Note: See TracBrowser for help on using the repository browser.