source: trunk/MagicSoft/Mars/NEWS@ 9347

Last change on this file since 9347 was 9347, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 130.4 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * There is no need to re-run any data because no change took place which
8 could have an effect on the output. However, if you want a
9 meaningful SrcPos plot for your MCs in sponde you must re-process
10 star for your MCs first.
11
12 ;general
13
14 * fixed a few small bugs which could cause the display to crash in ganymed
15 and sponde
16
17 * in sequence file the date can now be omittet. In this case the
18 leading date with the underscore is missing in the expected filename
19
20 ;automation
21
22 * added magnetic field Azimuth direction (ARRANG), currently
23 at ~ -7deg at La Palma
24
25
26 ;database
27
28 * plotdb.php: added default (sequences) for startup, added possibility
29 to set size of plot
30
31 ;merpp
32
33 * added support for Arehucas Version >= 200812140
34
35 ;mars
36
37 * The display now also displays the trigger pattern
38
39 * The display can now display ceres reflector (_R_) files
40
41 ;ceres
42
43 * added a uniformly distributed one-bin time jitter for the start of the
44 digitization. Otherwise the first photon would be digitized always with
45 the same alignment to the bins
46
47 * Added a plot showing the production height of the photons
48
49 * Moved the particle id from the event header to the run header
50
51 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
52
53 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
54
55 * Added many new options to control the tasks. For deatils see ''ceres.rc''
56
57 * Removed obsolete plots in pedestal and calibration mode
58
59 * Removed the non-NightSky photons from the plots where they are just
60 disturbing
61
62 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
63
64 * The daq event number now represents the readout number
65
66 * The camera ''electronics'' can now be ''switched off''
67
68 * A new tab ''info'' now display basic things like the reflector
69 layout
70
71 ;star
72
73 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
74
75 ;sponde
76
77 * The SrcPos plot for your MCs was so far meaningless because it just
78 displayes the MSrcPosCam data from the input star-files. Unfortunately,
79 this containes was never written to the star-files yet.
80
81 * A new Tab 'OnTime' is available which is an effective on-time
82 fit as in star but for all data. This is mainly for manual cross-check
83 of the effective on-time
84
85 * In some circumstances it might be necessary to re-calculate the
86 eff. on-time from the fit in the new tab, e.g. when a zenith distance
87 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
88
89 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
90 it to its own output file (for convinience)
91
92
93
94== Version 2.2 (2009/01/30) ==
95
96 ;SUGGESTION
97
98 * This release doesn't contain a major change which is expected to
99 change your results. Nevertheless there are small changes to
100 the calibration which can effect at least the first few hundred
101 events in any (mainly MUX and even more SUM) sequence a little bit.
102 So it is recommended although not necessary to reset your sequences
103 in the database before further processing.
104
105 ;NEW
106
107 * A first implementation of a Monte Carlo simulation program
108 (ceres - Camera Electronics and REflector Simulation) has been
109 implemented. It can simulate a full telescope already including
110 a complete reflector simulation and a flexible trigger and readout
111 simulation. Currently, no perfect setup is implemented and
112 especially the output of the program (data structure) should
113 be considered alpha state. Also the user interface is not yet
114 ready.
115
116 ;general
117
118 * All command line options after -- are now interpreted as
119 arguments (usually everything which doesn't start with a minus)
120 rather than options (usually everything which starts with a
121 minus). This allows to use file names starting with a -
122
123 * In all resource files you can now initialize the random number
124 generator. For details see: MJob::InitRandomNumberGenerator
125
126 * added a new program called ''readcorsika''. It's purpose is (in analogy
127 to readraw and readdaq) to read a Corsika output file (for now
128 only cherenkov output is supported) and print its contents in a
129 human readable form. It can also write the contents of this file
130 into a root-file.
131
132 * The calculation of the maximum distance to the origin in a MGeomCam
133 has been improved (edges might be further away than the sides).
134 This is just a tiny change but it might change the appearance of
135 the radial profiles a little bit.
136
137 * The default binning of the center-of-gravity plot has slightly been
138 increased
139
140 ;Database
141
142 * Added informations about the DC currents (fMinCurrents, fMedCurrents
143 and fMaxCurrents). The values are retrieved from the plots showing
144 the average DC currents of all pixels versus time.
145
146 * Websites with tables have now the opportunity to remove lines
147 ('-' button at beginning of each line) and get all lines back
148 ('+' at top of the column)
149
150 * Websites: added option to query only sequences containing sumtrigger
151 events
152
153 * Websites: added option to group by date (year, month, night) for runs
154 and sequences and enabled that combining of different group-bys,
155 e.g. status, date and source is possible
156
157 ;automatic analyis
158
159 * Rewritten producing plots in the web.
160 New plots, namely the output of plotoptical.C (extinction curve from
161 KVA), plotstat.C (status of the automatic analysis (percentage of
162 processed, analysed data etc.)) and plotusage.C (statistics of the
163 condor usage in the data center) has been are available now next to the
164 plots of plotdb.C
165 Mean values from the plots (output of the macro) are provided in a
166 txt file now.
167 The creation of the plots for callisto, star and ganymed in the web is
168 now steered via database. Consequently the plots are faster and
169 reliable up-to-date.
170 For all plots, a new layout is available facilitating the browsing
171 through the plots and providing additional information on the
172 displayed values. (tabs.php) These plots are linked from the DB
173 websites and the wiki.
174
175 ;statusdisplay
176
177 * The ''Loop'' entry in the menu bar now contains an option to pause
178 the loop and to process single events.
179
180 ;merpp
181
182 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
183 instead of RunHeaders)
184
185 * Now allows to merpp files newer than 2008/09/03.
186
187 * Added fixes for wrong (wrong or double) run- and file-numbers
188 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
189
190 ;callisto
191
192 * Extracting the pulse position for the pulse position check events
193 with sum trigger were denied. This decreased the statistics
194 extremely and therefor the resulting puse position was calculated
195 quite weak. Now sum events pass the calculation if and only if they
196 have also a level 1 trigger.
197
198 * the extraction of pedestal events and pulse position from the
199 first data events is now more automatic and makes sure that
200 a more precise number of events is extracted independent of
201 the ratio with which pedestal events or events with signals
202 are contained in the data.
203
204 * Updated Muon calibration constants for all MUX data (teh changes were
205 all smaller than 5%)
206
207 ;star
208
209 * For the calculation of the effective on time all sum-triggered events
210 were skipped. Now all Level1-triggeres events will pass. This might
211 result in a slight inaccuracy of the effective on time.
212
213 ;ganymed
214
215 * If the source position is more than 1deg away from the camera
216 center an error is raised now.
217
218 * Hopefully fixed the bug ''ganymed crashes when resized''
219
220 ;sponde
221
222 * Fixed a problem which causes the fitted spectral slope to be displayed
223 incorrectly. If you use MJSpectrum::FormFlux in your macros make
224 sure that the parameter 0 of your fit is negative.
225
226 * Added a histogram showing the read source position of your MCs
227
228
229
230== Version 2.1.1 (2008/08/04) ==
231
232 ;Database
233
234 * Added the median number of photo electrons from the calibration
235 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
236 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
237
238 * Added fTotOnTime, which is the on-time as given by the run-headers
239 (in contradiction to fAbsOnTime which comes from CC)
240
241 * Added new primaries for the new data structure (Magic II): for the
242 tables dealing with sequences (SequenceBuild Status, Sequences,
243 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
244 this is the telescope number (fTelescopeNumber) for the tables dealing
245 with runs (RunData and RunProcessStatus) this is in addition the file
246 number (fFileNumber)
247
248 * Added column fPriority to the status tables to be able to steer the order
249 in which the data is processed. As default the run, sequence and dataset
250 number are used.
251
252 ;automatic analyis
253
254 * Adapted scripts to the new data structure: They can handle now different
255 telescopes (getting the information as usual from the database).
256 The paths for Magic 2 are not yet implemented.
257
258 ;general
259
260 * should work now with root 5.20/00 (please note that root 5.20/00
261 we encounter crahses in the status display which are ot yet
262 understood)
263
264 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
265 instead of the base name of the file. This makes them easier to
266 access from the code
267
268 * Default Monte Carlo names in MSequence do not require the _E at
269 the end anymore
270
271 * where abrrevating a sequence file with a sequence number is possible
272 also "telescope:sequence" is now accepted, e.g.:
273 star 2:2000123 --out=output
274 see the programs' help for more details.
275
276 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
277 from the database. See the constructors for more details.
278
279 * MReadTree now supports friends
280
281 * MReadTree can now read also files not written by MARS and store
282 the data encapsulated in emulated MParContainers
283
284 * added a new starguider calibration valid since 15.1.08
285
286 ;showplot
287
288 * showplot can now read more than one file at once. This is especially
289 inetersting if reading files containing pure canvases
290
291 ;merpp
292
293 * we merpp the dc currents now also from the camera reports (they have
294 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
295
296 * In the automatic analysis we omit merpping of the currents from the
297 caco files and use the lower rate camera reports from the cc files
298 instead
299
300 * merpp has been redisigned to allow merpping of the cc-reports
301 of a whole sequence. This allows to design a very simple analysis:
302 mkdir output
303 ./callisto 100776 --out=output
304 ./merpp 100776 output
305 ./star 100776 --ind=output --out=output
306 Instead of the sequence number also sequence files are accepted.
307
308 * Implemented a fix for run-numbers between 1001348 and 1001396
309 which were incorrectly assigned by the cc.
310
311
312 ;callisto
313
314 * added a filter again which was was removed in the last release.
315 it removed the most brightest events. This should not change
316 any analysis result because these events are so bright that
317 they cannot be analysed anyway, but the bad-pixel plots doesn't
318 show outliers.
319
320 * updated muon calibration constants for the periods 51-57,
321 58-63 and 67-
322
323 ;star
324
325 * The camera currents are now displayed with the rate of the camera
326 reports instead of the caco reports
327
328 ;ganymed
329
330 * if mc camera files are new enough (>=8) the source position in the
331 camera is now calculated from the stored telscope and shower
332 orientation (Note, that this might not be suitable in all cases
333 depending on the aim of the study. These case still needs
334 implementation)
335
336
337
338== Version 2.1 (2008/06/18) ==
339
340 ;Database
341
342 * introduced average temperature and wind speed from star-files
343
344 * introduced average values from Pyrometer (mainly Cloudiness)
345
346 * introduced the ratio of accepted calibration events in the
347 calibration run
348
349 * introduced the average rates of the different trigger pattern,
350 e.g. the rate of pedestal and calibration events, from the signal-file
351
352 ;general
353
354 * fixed GroupBy options in plot*.C macros
355
356 * only display KVA points (not the Tuorla points) in plotoptical.C
357
358 * all programs now allow to add resources to the ones from the resource
359 file or overwrite them from the command line. This can be done like this
360 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
361 if something seems to be wrong you can debug what the program is doing
362 using the option --debug-env=3
363
364 * increased the diversity of debug levels. That also means that with -v3
365 you get now less output, i.e. only the output which is important for
366 an analysis. To get more output which helps for debugging try 4, 5 and 6.
367
368 * fixed a problem in the task synchronizing the reading of the reports
369 and the data stream. The effect was that in some circumstances the last
370 events of some trees could have been skipped. Since this is only a
371 very tiny part of the data no severe effect to your analysis results
372 is expected (an exception might be very short, i.e. singel runs,
373 datasets).
374
375 * Dataset file now allow to include the sequence file directly within
376 the dataset file and also allow to exclude single runs from the dataset.
377 (for more details see Class reference of MDataSet)
378
379 * Sequence files now allow for excluding runs from the analysis
380 (for more details see Class reference of MSequence)
381
382 * added code to process the sum-trigger flag
383
384 * the histogram classes MH3 and MHn now support profile histograms
385
386 * the histogram classes MH3 and MHn now support labels at the axis
387
388 * the Random Forest Train-classes (MJTRain*) now store the used datasets
389 in the output file
390
391 * the MFMagicCuts have a new option to allow a linear area cut (for
392 special studies)
393
394 * The liniking of the shared object is now done into a file defined
395 by 'mktemp'. This should be a local file system which accelerates
396 liniking a lot.
397
398 * The code has been prepared for compilation with root 5.18/00d
399
400 * The MHEnergyEst histogram now shows the distribution of
401 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
402 and (Eest-Emc)/Emc vs Emc.
403
404 * fixed mars (event display) for merpped raw-data and MC data
405
406 * adapted the synatx of sequence files to allow for the new run/file
407 scheme. For more details see class description of MSequence
408
409 ;showplot
410
411 * Added support for tiff files
412
413 * Added support for csv files (tables containing tab number,
414 name and title)
415
416 * Tabs now can have a title which is displayed in the postscript file
417
418 * When multiple file are written at once (e.g. pngs from a display)
419 it is now possible to use the tab name and or tab number in the
420 file name. For details see showplos's help.
421
422 ;merpp
423
424 * Implemented cc file version 2008-02-20/0
425
426 * Implemented cc file version 2008-05-19/0
427
428 * With new options merpping can be restricted (in addition to the
429 run-number) also by telescope and file number.
430 For details see "merpp --help"
431
432 * Implemented raw data format 11 (the most important change, except
433 from plenty of changes in the format definition, is the addition
434 of the file-number in the header) If nobody makes a mistake this
435 format should have the advantage that it is by definition forward
436 compatible, so old programs will be able to read newer formats.
437
438 * Added Pyrometer information to default output (stored in a new Tree
439 Pyrometer, needs a complete new merpp, i.e. new calibration)
440
441 * Merpping (also update) can now be restricted to one single report.
442 For example:
443 If you want to update an old file with Pyrometer information call
444 merpp --only=Pyrometer --update
445
446 ;callisto
447
448 * in the pedestal processing now at least 50 processed events are
449 required for succeeding.
450
451 * the signal and calib files now contain also the sequence information
452
453 * the two MPedestalCam in the calib file now have proper names
454 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
455
456 * Both pedestal cams now contain the number of events processed
457
458 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
459 i.e. for the extraction of the calibration pulses basically the average
460 over all events of the first slice instead of all slices was used.
461 Since pedestal and calibration constants are continously recalculated
462 this only effected the very first events of every sequence.
463
464 * For the extraction of the position of the maximum sample now the
465 extraction range is set automatically to the extraction window,
466 before the whole accessible range was used.
467
468 * If the number of samples in the events and the number of samples
469 in the run-header disagrees now an error is raised (this can
470 happen in not well simulated Monte Carlo files)
471
472 * In the case of MUX-data pedestal events with the lvl1 trigger flag
473 could survive into the pedestal calculation -- fixed.
474
475 * Tab "TrigPat" added showing the distribution of the trigger pattern
476 as found in the run-files (normalized with the run length)
477
478 * The selection of events from the trigger pattern has been improved.
479 If the trigger pattern is corrupted events won't pass anymore.
480
481 * Added a new command line option --dev-null to suppress output of
482 Y-files (this is useful for test cases)
483
484 * added a new tab "CalPos" showing the arrival time of extracted
485 interleaved calibration events
486
487 ;star
488
489 * the star file now contains also the sequence information
490
491 * Added a new command line option --dev-null to suppress output of
492 I-files (this is useful for test cases)
493
494 * Tab "Rate" added showing the distribution of the trigger pattern
495 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
496 the Y-files (normalized with the run length)
497
498 * The effective on-time calculation doesn't use events with only
499 sum-trigger anymore
500
501 * The data in the MHWeather tab has been reorganized. The never
502 working solar radiation has been removed and the data from
503 the pyrometer (cloudiness, air and sky temperature) is
504 displayed in addition.
505
506 ;ganymed/sponde
507
508 * Now data points are even shown correctly if they have error bars larger
509 than one sigma. Points with null or negative significances are omitted.
510
511 * DrawNicePlot now allows to set a projection range
512
513 * Updates pointing models. One is applied after the implementation
514 of the new LUTS in August, the other one is applied after the
515 next major change of the pointing model in October. Note that
516 these models are preliminary and give wrong results below Zd=65deg
517
518 ;sponde
519
520 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
521
522 * a new option "--force-runtime" is available. In case of very short
523 datasets (for light-curves) which are in the order of a few
524 minutes the calculated effective on-time is not very acurate because
525 it is quantizised in the order of a minute. Therefore you can switch
526 to using the real run-time instead (remakrt: this ignores any
527 dead-time!)
528
529 * a more analytical way is used to "fill" Monte Carlos into regions
530 of impact parameters which have not been simulated because the
531 trigger efficiency is assumed to be 0.
532
533 * estimated sensitivity curves for hi and lo zenith angles are shown
534 scaled to the correct observation time and collection area
535
536 * the Monte Carlo events after cuts are now written to the output file
537 if an output file given
538
539
540
541 *** Version 2.0 (2007/09/03)
542
543 - database: the position used for the pulse pos check was missing
544 in the callisto output and could thus not be filled into the DB.
545 Also the old values seemed not exactly the PulsePos used for
546 teh check.
547
548 - general: Resource file now allow an Include-Resource, i.e. you can
549 read a resource file with default settings, include it in your
550 resource file and overwrite the settings in your file. More than
551 one include file is allowed. Inclusions can be iterative.
552 Include: mydefaults.rc yourdefaults.rc
553 The resources in the first file have higher priority than the
554 second file.
555
556 - general: Now the output files (calib*.root, etc) also contain the
557 resource file (to check it open it in the TBrowser and choose Print()
558 from the context menu)
559
560 - general: Dataset files now allow to overwrite the default path
561 to search for sequence and data files. Note, that the program
562 option and individual resources will overwrite it. For example:
563 SequencePath: /magic/montecarlo/sequences
564 DataPath: /magic/montecarlo/star
565
566 - general: Fixed a problem with variables in MDataPhrase. It seems
567 that only optimdisp (didn't work) was effected.
568
569 - general: Some improvements to the optim and train processing. For
570 example the ststud window now got a proper title.
571
572 - general: The "Status Display: " was removed from the window title
573 within an Eventloop.
574
575 - general: added a new flexible histogram-class (MHn) which can be used
576 for example in testing after optimizations or training to produce
577 user defined histograms.
578
579 - general: The Random Forest now allows attaching an evaluation
580 function which is applied to its output. This allows to train
581 on whatever you like (eg. train on log10(energy), but return
582 energy)
583
584 - general: The Random Forest training of energy (trainenergy.c) and
585 disp (traindisp.C) has been improved by more graphical output to
586 judge the result.
587
588 - general: The training of energy (trainenergy.C) has been improved
589 a lot by training on a different quantity than energy. It gives
590 a result which is highly independant of the source spectrum
591 and shows lower bias than all other options.
592
593 - general: Dataset files are allowed to contain collections of
594 datasets. For more details see the class reference of MDataSet.
595
596 - general: The default WobbleMode in a datset file now (if not
597 overwritten) is "auto", i.e. wobble mode is set if the dataset
598 doesn't contain off-sequences.
599
600 - merpp: Merpp can read file format version 9 now. Please realize
601 that for file format version 9 the extraction range is different
602 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
603 the first and last 15 slices have been removed from all MUX data.
604
605 - mars: Similar to writing movies you can now select events which
606 should be displayed in your display. Therefore add the following
607 lines to your mars.rc:
608 MFEvtNumber.FileName: ganymed00223552.root
609 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
610 The input file can be a ganymed-file after (ganymed*.root) or
611 before (ganymed*-summary.root) file. For example to select all events
612 from your on sample after cuts (excluding the ThetaSq cut) use
613 MFEvtNumber.Selector: DataType.fVal>0.5
614 To show all events from your on-sample after quality cuts
615 use the summary file instead.
616
617 - mars: new ways to call mars are implemented. Instead
618 of calling
619 mars filename.root
620 you can now also use
621 mars sequence.txt
622 or
623 mars sequence.txt inputpath
624 or replace sequence.txt by the sequence number if the default
625 sequence file should be used.
626
627 - mars: The default size has been increased
628
629 - mars: There are two new heckboxes which allow to switch off
630 the calculated image parameters
631
632 - callisto: was broken for MCs... fixed.
633
634 - callisto: improved calculation of spline coefficients a lot. This
635 leads to a further improvement of the event rate calibrating MUX
636 data of about 15% (175evt/s instead of 150evt/s)
637
638 - callisto: finally the raw data we read is now real 16bit (with
639 10bit precision) for MUX data and not a stripped 8bit number
640 anymore. Due to scaling of the numbers (without precision loss
641 into an [0-256[ range, the final numbers for pedestal, pedestalrms
642 and extacted signal don't change. However, at all places where
643 raw data is directly accessed (eg. saturation and variation
644 limits in the signal- and pedestal-extraction) the numbers
645 refer still to the data's 16bit range.
646
647 - callisto: The maximum arrival time difference used in the bad
648 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
649 for both, old FADC and MUX-FADC, data.
650
651 - callisto: Be aware that callisto is now calibrating the arrival time
652 in nanoseconds rather than time slices. Also all following tasks
653 have been changed to assume ns units now. If you star data
654 calibrated with an older version it might be necessary to adapt
655 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
656 to obtain optimal results. The plot in the PulsePos tab
657 will now be in ns, too. This might also mean that the Muon
658 analysis in star might not work as perfect as expected as long
659 as old files read in.
660
661 - callisto: The calibration constants of earlier updates got lost
662 somehow. All constants have been updated.
663
664 - star: The PSF is now determined from the profile of the ArcWidth
665 instead of arcwidth/radius. The old way gave to much weight
666 to the bins with low statistics. The reference lines have been
667 updated.
668
669 - star: For speed reasons events suitable for the muon analysis
670 are now also preselected by fConcCOG<0.1 which seems to be a very
671 good preselector for muons.
672
673 - star: is now calculating a new timing parameter the Slope along
674 the major and minor axis of the shower. Therefore a numerical
675 solution of a line-fit is used. To use MHillasExt.fSlopeLong
676 and MHillasExt.fSlopeTrans don't forget to multiply it with
677 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
678
679 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
680 have been removed from MNewImagePar. They have never been good for
681 anything.
682
683 - star: Implemented a new recursive algorithm which is supposed to be
684 faster. Also implemented new cleaning oiptions, which are:
685 + CleanLevel0:
686 The cleaning level above single core pixels can be kept
687 + KeepIsolatedPixels:
688 Define whether single core pixels should be kept
689 + TimeLevel1:
690 The coincidence window in nanoseconds to single used neighbors
691 + TimeLevel2:
692 The coincidence window in nanoseconds to two used neighbors
693 + PostCleanType:
694 MOde in which a time dependent post cleaning should be applied
695 0: No post cleaning
696 1: Require for each used pixels at least one used neighbor
697 within a time-window of CleanLevel1
698 2: Require for each used pixels at least two used neighbor
699 within a time-window of CleanLevel2
700 3: Require first two and second one used neighbor
701 within a time-window of CleanLevel1 and fCleanLevel2
702 respectively
703 + RecoverIsolatedPixels:
704 - recoveres isolated core pixels if they have a used neighbor
705
706 - mars/star: The new default cleaning is:
707 + CleanLevel1: 6.0
708 + CleanLevel2: 3.0
709 + CleanTime1: 1.75
710 + CleanTime2: 1.75
711 + PostCleanType: 3
712
713 - star/ganymed: The old spark-cuts have been replaced by new ones.
714 These new spark cuts have been cross checked with the sequences
715 84720 (before splitter), 101041 (after splitter) and 223539 (new
716 FADCs). In all cases they seperate pretty well, but of course not
717 perfect. Monte Carlos have suggested to tighten the cuts a little
718 bit further at low sizes. This has been done.
719
720 - ganymed: IMPORTANT - The spark cuts have been changed to match
721 all available data more or less well. This might mean that for
722 YOUR data there are still sparks visible.
723 Whenever you do an analysis you have to make sure that NO sparks
724 survive your cuts!
725
726 - ganymed: The old hadronness and size cuts have gotten new indices
727 (10, 11). The old indices 8 and 9 now mean an additional condition
728 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
729 If you want to switch off this cut just move the line far away enough,
730 e.g. by setting c[9] to -500. Please update your ganymed.rc files
731 accordingly!
732 The unit of c[9] is deg. It is the dist at which your cut will
733 cross the slope==0. The unit of the slope is ns/deg. So if
734 you readin files calibrated with an older Mars-version you
735 have to adapt the default value for c[9] to the FADCs:
736 - Multiply by two for the MUX FADCs (run number > 200.000)
737 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
738 - Multiply by 42 for the meaning of life (run number = 200.000)
739
740 - ganymed: The old Cut0 is now called CutQ and is calculated before
741 the source position is caluclated. If you need a quality cut
742 including source dependant data (be very carefull with this!)
743 you have to use Cut0 instead.
744
745 - ganymed: now properly supports three off regions in wobble mode.
746 It will be the default from now on in ganymed_wobble.rc. To change
747 the number of off-regions use
748 NumOffSourcePositions: 1
749 in your ganymed.rc. Also by default no off-theta cut will be done
750 anymore so that you will get a background level higher than the
751 signal level in your ThetaSq plot for ThetaSq>0.2.
752 Due to this be carefull changing the scaling mode away from
753 "None". You will underestimate your signal if your scale interval
754 is not properly set.
755 (Rem: ThetaSqN is no longer needed)
756
757 - ganymed: is now storing the events of all (on- and off-)
758 source positions even in the case of more than one off-source
759 position. This should allow sponde to work properly and the
760 energy estimation is done correctly in all cases (without any
761 "nearest position" trick)
762
763 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
764 with a real pointing model for the starguider is done, calibrated
765 with more than thousand tpoints taken from this date on.
766
767 - ganymed: was broken for Wobble-MCs... fixed.
768
769 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
770 has changed. Note that your old ganymed.rc will be incompatible
771 with the new algorithms! Please check the ganymed.rc files and
772 the class description of MFMagicCuts for more information.
773 It is recommended at the moment to use identical Disp-Parametrizations
774 for on/off- and wobble-mode. If cuts are optimized only
775 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
776 should be optimized. All other values should be kept as they are.
777 If you want to do an anylsis without timing a parameters, you can
778 switch off the timing cuts by seeting parameter 7 to a very small
779 value (eg. -99). To remove the slope parameter from the disp
780 paremtrization set parameter 8 to 0.
781
782 - ganymed: The distribution of observation time versus zenith
783 angle is now shown for off- AND on-data.
784
785 - ganymed: The contents of the source position plot are no longer
786 averaged, thus a lot of (fake) events between the two wobble
787 positions have disappeared.
788
789 - ganymed: There is a new tab "CutT" it contains the VsSize plots
790 with the CutT, whihc is defined in ganymed.rc, applied. It
791 is resonable to use your theta-cut for it, to see if there is
792 something strange (sparks!) in your signal-region.
793
794 - ganymed: To choose a dataset from a collection in a dataset file
795 use the new command line option "--dataset=12345"
796
797 - optim, sponde: should now properly support three off-regions.
798 Just produce your ganymed summary files with three off-regions.
799 optim and sponde will automatically get all off events from
800 all off-regions from this file. Please do not forget to
801 set the scaling in optimwobble.C properly:
802 fit.SetScaleUser(1./3);
803 it is not yet read in automatically (will follow soon).
804 In the case of fixed Scale you can also use
805 cuts.SetThetaCut(MFMagicCuts::kOn);
806 no off-cut needed.
807 Be carefull in case of three off-regions when switching on
808 scale mode. Make sure that the scale interval is set correctly.
809
810 - sponde: sponde.rc and sponde_onoff.rc are now idetical
811
812 - sponde: the resouce files have been rewritten with a lot of
813 comments and a well working parametrization for an energy estimator
814
815 - sponde: In the estimated energy versus monte carlo energy plot the
816 contents where exchanged.... fixed.
817
818 - sponde: the so called "accurate"-mode has been removed. It didn't
819 give any improvement in accuracy, only decreased execution speed.
820
821 - sponde: the so called "simple"-mode has been removed. It didn't
822 give any improvement in simple.
823
824 - sponde: the so called "refill"-mode has been removed. It was anyhow
825 not implemented.
826
827 - sponde: now checks whether the theta distribution of your on-data
828 and the theta-distribution of your Monte Carlo sample (after
829 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
830 sample is incomplete) execution is stopped. Execution can be forced
831 using the new option --force-theta. Use this option with care!
832
833 - sponde: Proper collection areas can now be constructed also from
834 Monte Carlo samples generated with different maximum impact
835 parameters. Note that in previous version you neither got
836 a warning or failure, nor was there any obvious sign that the
837 collection area was overestimated due to usage of files with
838 different maximum impact parameters.
839
840 - sponde: If MC files with different lower energy limits are used
841 the primary MC spectrum is artificially completed down to the
842 lowest energy used at all. WARNING: that this gives correct
843 collection areas ONLY if none of the events in this region would
844 survive your cuts at all.
845
846 - sponde: the output file now contains more information about
847 the spectrum (eg. the full 2D collection area histogram).
848 Note, that this information can only be written to the file
849 if it is stored automatically via command line argument.
850 If you only store the status display from within the display
851 the information is lost.
852
853 - sponde: added a new tab "Disp". It shows the residual of the disp
854 (Disp-Dist) versus several parameters and it is meant to judge the
855 quality of the disp estimator. In the ideal case the residual is zero
856 and doesn't depend on any variable. The tab is displayed after
857 CutQ and Cut0.
858
859 - sponde: added a new tab "Energy". It shows the residual of the
860 energy (lg(estimated energy)-lg(monte carlo energy)) versus
861 several parameters and it is meant to judge the quality of the
862 energy estimator. In the ideal case the residual is zero
863 and doesn't depend on any variable. In reality even a good estimator
864 can show residuals versus Monte Carlo energy. The tab is displayed
865 after all cuts.
866
867 - sponde: added a new tab "EventDist" showing the unweighted real
868 absolute number of events of your sample after cuts. This tells
869 you how many events with this energy you had in your MC files.
870 The same information you get from the error bars of the weighted
871 histograms, but this is less intuitive.
872
873 - sponde: The spectrum plots now show the crab- and 1553-spectrum
874 for comparison. It is not meant to show these curves in
875 publications, they are only for production.
876
877 - sponde: The OriginalMC tree with the events produced by corsika
878 is now processed only once
879
880 - sponde: Finally fixed most annoying bug, which has effected the
881 last bin of the collection area. It was the problem that binnings
882 of root histograms are from 1 to n (included) but there was a C-like
883 loop in sponde from 0 to n (excluded). Now the loop also includes
884 correctly under- and overflow-bins. The worse thing with this is,
885 that for the events in the highest bin not only the bin-content
886 was wrong, but also the weights applied to these events, which could
887 in pricipal effect also other parts of the distribution (eg. due
888 to energy estimation). Fortunately it effected only a few events
889 in most cases.
890
891
892
893 *** Version 1.2 (2007/05/14)
894
895 - database: The database now has two new values Unsuitable50 and
896 Unsuitable01. They express the number of pixels which are
897 unsuitable for more than 50%, respectively more than 1%, of
898 all calibrated event. It is a more accurate number than the
899 previously used numbers, because they only take the first
900 calibration (ignoring the interleaved calibrations) into account.
901
902 - database: The database now has two other new values UnsuitableMax and
903 DeadMax. They express the maximum number of pixels which were
904 unsuitable, respectively dead, during the sequence. Because
905 of high pedestal rms (cars passing) a few events with very high
906 numbers of unsuitable pixels can happen. Not to suffer from this
907 effect we don't take the highest 0.1% of the numbers into account.
908
909 - general: fixed a bug which caused callisto and star to stop working
910 properly because the callisto output was currupted
911
912 - general: a script called scripts/makemovie has been added which
913 simplified the process of producing several movies from a single
914 sequence with different setup.
915
916 - callisto: Some more code cleanup. Started to remove old obsolete
917 code from cvs.
918
919 - callisto: The extraction of the pedestal with the extractor was
920 not random. It seems that extracting at one position is still biased
921 (for example in the first or last slices we could still suffer from
922 switching noise) Now it is completely random.
923
924 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
925 pedestal files) individual pixels could be skipped due to high
926 variations. This was already the case for the pedestal extraction
927 from the lo-gains since the beginning and properly handled
928 there, but was introduced in the extraction from the pedestal files
929 a while ago. To calculate the average value it was still divided
930 by the number of events procesed not by the number of summands
931 really summed. This let to a pedestal which was a tiny amount too
932 small (for a few piels in the order of 0.1%). This led to an slightly
933 positive offset of the randomly extracted pedestal for a few pixels.
934 I doubt that this has a big effect on the result, because the effect
935 on the individual numbers is quite small. Due to this it is suggested
936 that you rerun your calibration to make sure you are without any
937 avoidable bias.
938
939 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
940 the median rms of the absolute arrival time and expressed in significance
941 levels. This replaces the old meaning of an abolute upper limit. An
942 absolute upper limit doesn't make much sense, because in our data
943 all arrival times are shifted at the same time (in fact it might be
944 a shift of the artificial trigger w.r.t. to the light flash).
945
946 - callisto: Added a new tab "BadPixTm" which shows the time evolution
947 of the number of unsuitable pixels over the whole sequence. This
948 is usefull mainly to judge if an intermediate calibration had
949 problems.
950
951 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
952 of the number of dead pixels over the whole sequence. Dead pixels
953 in this context are unmapped pixels, i.e. pixels which could not
954 be interpolated, and thus are ignored in the further analysis.
955
956 - callisto: It is now possible to use the position of the maximum
957 of the spline as arrival time instead of the leading edge even
958 when using the integral for the signal. Therefor set the extraction
959 type to kIntegralRel ("IntegralRelative") and the relative height
960 ("HeightTm") to -1:
961 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
962 MJPedestalC1.ExtractSignal.HeightTm: -1
963
964
965
966
967 *** Version 1.1 (2007/04/27)
968
969 - general: The new class MGeomCamDwarf contains the camera geometry
970 for our prefered Dwarf camera and can be used to create general
971 geometries of roundish or hexagonal cameras.
972
973 - mars: The default cleaning is now abolute 8.5/4.0.
974
975 - mars: The resource file mars.rc now contains examples for MUX data
976
977 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
978 data containing only 10-bit information is still cooked down to
979 8-bit, by cutting away the lowest 8-bit.
980
981 - merpp: When reading raw data the data is now stored in a single
982 array. The lo-gain array is obsolete. The interface stays the same.
983
984 - callisto: To process the new MUX data use the resource file
985 callisto_mux.rc
986
987 - callisto: The -root and -raw options to read merpped raw data have
988 been removed
989
990 - callisto: If the -mc option is given the sequence-name can now be
991 replaced by the MC sequence number
992
993 - callisto: If the sequence file contains "MonteCarlo: Yes" the
994 -mc option can now be omitted
995
996 - callisto: Started further simplification by removing obsolete
997 dependancies on MCalibIntensity*Cams.
998
999 - callisto: removed unsused intensity calibration from MJCalibration
1000 for further simplification
1001
1002 - callisto: for simplification removed references to
1003 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1004 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1005 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1006 (this should at minimum change nothing at all, and at maximum
1007 improve thing if these containers where somewhere not handled
1008 properly)
1009
1010 - callisto: Added the option to write an event movie. Please use
1011 this option with care (huge files) but exessively to understand
1012 our events. For further documentation please refer to the
1013 IACT wiki
1014 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1015
1016 - callisto: Improved binning for the pulse position check histogram
1017
1018 - callisto: The code calculating the pulse position checknow takes
1019 the pedestal into account
1020
1021 - callisto: The arrival time is now stored with full precision this
1022 helps to get rid of artefacts in histograms. For the signal this
1023 is not necessray because it is displayed in log-scale anyhow
1024
1025 - callisto: Fixed a problem with internal exclusions. Pixels which
1026 have once been marked as unsuitable didn't get the necessary
1027 histograms filled anymore to be rechecked with each interleaved
1028 calibration.
1029
1030 - callisto: The relative arrival time resolution (the rms of the
1031 relative arrival time offset) is now checked against its
1032 median and the median deviation, instead of the average
1033 plus an absolute offset.
1034
1035 - callisto: The relative arrival time offset is now calculated
1036 w.r.t. its median not w.r.t. to an artificial reference pixel.
1037
1038 - callisto: The relative time calibration now marks pixels with
1039 outlaying offset as unsuitable
1040
1041 - callisto: The interleaved relative time calibration has been switched
1042 on. The advantage is that pixels which are marked as outliers
1043 now can recover. An improvement over time is not expected, because
1044 the relative time calibration seems stable.
1045
1046 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1047 option can now be omitted.
1048
1049 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1050 or the option "-mc" is specified as default the monte carlo datacenter
1051 paths (/magic/montecarlo/...) are used if not overwritten in the
1052 dataset file.
1053
1054 - ganymed: The output files now contain run- and event-number for all
1055 events, accessible as RunNumber.fVal and EvtNumber.fVal
1056
1057 - ganymed: Added a plot showing the source position in the camera also
1058 for wobble mode
1059
1060 - ganymed: In addition to the existing task which can be setup to
1061 be executed after Cut1 a final task called "EstimateEnergy"
1062 has been added, executed before writing the final output
1063 (ganymed00000000.root). The task setup in all three cases
1064 can be choosen individually. (For all three(!) cases you
1065 can for example choose MRanForestCalc. For examples see all
1066 sponde*.rc and all ganymed*rc)
1067
1068 - ganymed: If a container "MEstimatedEnergy" is found in the
1069 parameter list (eg. because it was setup by MEstimateEnergy)
1070 it will be written to the output file.
1071
1072
1073
1074 *** Version 1.0 (2007/02/16)
1075
1076 - database: Website to plot values from the database has been added.
1077
1078 - database: The rate of spark events as found by star is now kept
1079 and the rate after cleaning is now with spark events subtracted
1080
1081 - general: The changes to the interpretation of phrases lead to
1082 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1083
1084 - general: Added example files how you can create your own calendar
1085 (eg. as christmas present) with Mars. Just run
1086 root macros/tutorials/calendar.C
1087
1088 - general: Added a possibility to display grouped data in the plotdb.C
1089 macro (and similar macros). This allows to plot hourly, nightly,
1090 weekly, monthly and yearly averages.
1091 For more details see the plotall function of the macro
1092
1093 - general: fixed the error display of the camera display. It showed
1094 wrong results.
1095
1096 - general: fixed a memory leak when reading many MStatusDisplays
1097
1098 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1099 between a spherical and a parabolic mirror
1100
1101 - callisto: We have a new pulse position check which takes the properties
1102 of the extractor automatically into account. So no need to set
1103 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1104 left is done. If possible the lo-gain extraction start and hi-gain
1105 extraction end is changed accordingly. If no proper extraction range
1106 can be set (hi-gain too much to the left) an error is raised.
1107
1108 - callisto: New swapped pixels have been found and corrected
1109
1110 - callisto: Redone the signal extraction this includes:
1111 + Unified the algorithms to extract the pedestal for all pedestal
1112 extractions done
1113 + Unification of hi- and lo-gain into one array
1114 + Unification of hi- and lo-gain extraction for Spline and
1115 Digital Filter (means now exactly the same algorithm is used,
1116 not a copy-and-pasted one)
1117 + Store pedestal subtracted data in a common place
1118 + Improved extraction algorithms. If the algorithms search a
1119 maximum but don't find one they don't return the maximum anymore
1120 + Improved the extraction such that a information for signal
1121 and time which is consistent is returned
1122 + replaced the numerical spline with a (not slower) analytical
1123 solution
1124 + Lowered the saturation limit from 250 to 245 to make sure that
1125 we are far away in all pixels from problems with the clock-noise
1126 + The start of the lo-gain extraction is calculated from the hi-gain
1127 arrival time. In case of saturation an estimation is used.
1128 + the hi-gain window was extended to slice 16. This allows extraction
1129 of very late pulses in single pixels or of huge hadron showers.
1130 + Now uses the lo-gain extraction range for pedestal extraction,
1131 not the hi-gain range in the lo-gain
1132
1133 - callisto: New hi-/lo-gain calibration constants have been produced
1134 for all periods from the statistic of the whole period. They are
1135 now used automatically depending on the periods. The old constants
1136 where deviation in avarega about 2%-3%. The constants are very
1137 stable from period to period (<<1%) except for exchanged channels.
1138 In a few cases the constants used so far were off by 1%-2% (maybe
1139 temperature effects?)
1140
1141 - callisto: To gain obsolete space we do not write the
1142 MPedestalFundamental anymore. Also calibration and bad pixel
1143 treatment is not done for it anymore because it has never been used.
1144
1145 - callisto: Fixed a bug in the seuqence handling which caused the
1146 light condition to be ignored
1147
1148 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1149 basically the same as "Cleaned" but the distribution devided into
1150 the events fullfilling a spark cut or being rejected by it.
1151 This cut can be changed from star.rc (see example inside) by
1152 the "SparkCut" directive
1153
1154 - star: Star displays now the average individual pixel-rate (IPR) versus
1155 time and the average discriminator threshold (DT) of all pixels.
1156
1157 - optim: fixed a problem with the optim-macros which was due to a bug
1158 in the new phrase parsing
1159
1160 - ganymed: To get a nice FalseSource plot (instead of the all-information
1161 debug plot displayed as a standard plot) use the context menu
1162 somewhere between the two upper plots, click on "DrawNicePlot"
1163 and enjoy the result. (It is the same context menu which contains
1164 the other options)
1165 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1166
1167 - ganymed/optim/train: The cut program, trainings- and optimization
1168 macros could run with less files found than expected from the
1169 sequence-files. No the execution is stopped in this case.
1170
1171 - ganymed: now stores the dataset in the output file with all information
1172 contained (as sequence number, sequence path, data path) so that the
1173 used dataset file can be recreated complete from the output
1174
1175 - sponde: now also allows the uasge of random forest
1176
1177 - sponde: added a plot showing the cut efficiency
1178
1179 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1180 errors (eg. effecting the collection area) because the errors of the
1181 two histograms were swapped in the calculation, which makes a difference
1182 in the case the histograms contains weighted events. Aditionally the
1183 totalarea was incorrectly taken into account, which results in too small
1184 errors, which makes a difference at low statistics were the errors
1185 or the collection area dominate.
1186
1187
1188
1189 *** Version 0.10.3 (2006/10/23)
1190
1191 - database: Implemented ObservationMode flag in websites.
1192
1193 - database: For sequences there is now also the stoptime available on the
1194 websites.
1195
1196 - database: Removed ManuallyChanged flag from sequence-info websites,
1197 as it is not needed anymore with the new sequence building algorithm.
1198
1199 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1200 Class for calculation of confidence intervals (upper limits).
1201 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1202 Please read the class instruction of TRolke for more information.
1203
1204 - general: The programs now return 0xfe if the requested resource file
1205 doesn't exist.
1206
1207 - general: Errors comming from root itself are now not output to
1208 stderr anymore but to our default (colored) log-stream.
1209
1210 - general: Changed the interface to TFormula such that now everything
1211 is parsed by TFormula, which should allow to use phrases even
1212 without paranthesis correctly parsed.
1213
1214 - callisto: replaced the AdHoc number of effective integration slices
1215 in the digital filter by an average of the correct number, averaged
1216 over all possible set of weights. This also gives correct numbers
1217 for the lo-gains which were totally wrong before.
1218
1219 - callisto: drastically reduced memory consumption by not storing
1220 all intermediate calibration results in memory anymore (we might
1221 write them into a file in the future)
1222
1223 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1224 debug plot displayed as a standard plot) use the context menu
1225 somewhere between the two upper plots, click on "DrawNicePlot"
1226 and enjoy the result. (It is the same context menu which contains
1227 the "DrawAll" option)
1228 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1229
1230
1231
1232 *** Version 0.10.2 (2006/10/15)
1233
1234 - general: changed the building of the sequence files such, that
1235 the source-/project name in case of wobble-sources is not the
1236 source/project of the first data run anymore but the new generalized
1237 wobble source/project
1238
1239 - general: Added some functions to MAstro to calculate sun and
1240 moon properties
1241
1242 - general: Added two new macros (starvisday.C and starvisyear.C)
1243 which allow to plot the visibility of several stars in one day
1244 or of one star along one year
1245
1246
1247
1248 *** Version 0.10.1 (2006/10/11)
1249
1250 - general: HTML logging output was distorted... fixed.
1251
1252 - general: Changed the writing of the sequencefiles such that only
1253 as many pedestal files as giving at least 1000 pedestal events which
1254 are nearby the first calibration run are used as pedestal runs
1255
1256 - sponde: In the calculation of the collection area(s) and the
1257 distribution for MOnte Carlo and estimated energy the error
1258 calculation was wrong because root didn't take the errors
1259 properly into account... fixed.
1260
1261
1262
1263 *** Version 0.10 (2006/10/10)
1264
1265 - general: all executables now check consistency of the root version
1266 installed with the root version used for compilation. The return
1267 code in this case is 255.
1268
1269 - general: The algorithm to build seqeunces has been redesigned
1270 completly. It is now more flexible in terms of a resource file
1271 resources/sequences.rc which can be used to partly overwrite
1272 the default algorithm and defined the important part of the
1273 algorithm. It also takes correctly into account several ways
1274 of taking wobble-data. Currently the new algorithm doesn't take
1275 the number of pedestal events anymore into account (so a sequence
1276 could have much less than 1000 pedestal events and data runs are
1277 no-more used instead)
1278
1279 - general: a lot of small changes to make the code compatible with
1280 root 5.12/00 and gcc 4.1
1281
1282 - general: Fixed some warnings thrown if more warnings are switched
1283 on in the compiler
1284
1285 - general: Added a function to MMath which returns the Median of
1286 the distribution abs(y[i]-median) but at 68:32 division instead
1287 of 50:50, which is somehow the median counterpart of the rms.
1288
1289 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1290 even if they are compressed with gzip (recommended compression
1291 is with "-1")
1292
1293 - showplot:
1294 + batch mode creation of image files now works with root 5.12/00
1295 + added support for writing bmp (though it never produces
1296 bmp which can be read by programs like xv or gimp)
1297 + added support for xml
1298 + added new option to start the display with a different size, by
1299 --display-width=nnn or --display-height=nnn
1300 + added options to define the canvas size when the display is started
1301 --canvas-width=nnn or --canvas-height=nnn
1302 the option can also be used for batch-mode conversion
1303 + added an option which automatically fits the display size to the
1304 desktop-size: --auto-size
1305
1306 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1307
1308 - merpp: allow the reports to have 1000ms due to a bug in the camera
1309 program.
1310
1311 - callisto: New swapped pixels have been found and corrected. For
1312 details see MRawRunHeader::FixAssignment()
1313
1314 - callisto: Callisto now raises an error if one of the input files could
1315 not be opened.
1316
1317 - callisto: In some rare cases it could happen that in the signal
1318 extraction of the digital filter the extractor returned nonsense
1319 results due a wrong initializion of a variable (this happens in
1320 cases in which the extracted signal is exactly zero or the
1321 digital filter couldn't slide because of a too small extraction
1322 window, which could happen in the lo-gain extraction)
1323
1324 - callisto: The lo-gains have been marked as valid in some cases
1325 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1326 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1327 smaller than the number of slices (fLoGainWindowSize) needed
1328 by the lo-gain extractor
1329
1330 - callisto: Updated absolute calibration constants (muon calibration)
1331
1332 - callisto: fixed a bug which caused the hi-gain saturation not
1333 to be handled properly in the spline (the position of the
1334 saturation was calculated incorrectly)
1335
1336 - callisto: fixed a bug which gave weird results if hi- _and_
1337 lo-gain could not be extracted properly. In some cases hi-
1338 and lo-gain have not been extracted at all and the random result
1339 got calibrated. In other cases the hi-gain was saturating and the
1340 lo-gain has not been extracted. For this a completly arbitraty
1341 scale factor was applied to the result from extracting the
1342 charge of the saturating hi-gain.
1343
1344 - callisto: improves handling of extracted signal if lo- and/or
1345 hi-gain could not be extracted properly. If no appropriate
1346 calibration of either the signal or the arrival time is possible
1347 the pixel is now markes as unsuitable instead of estimated.
1348
1349 - callisto: Fixed a problem in the spline extraction which gave
1350 weird results if the signal was extracted from the first (and
1351 highest) slice (as a workaround extraction from the first
1352 slice has been forbidden)
1353
1354 - callisto: Fixed a bug regarding the use of the QE which doesn't
1355 effect the result because the default is used anyhow.
1356 (The bug was there since 14/07/2005)
1357
1358 - callisto: Changed the default for fgLoGainStartShift to -2.4
1359
1360 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1361 factors to be always 10 for all pixels as soon as the first
1362 calibration update has happend.
1363
1364 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1365 was off by more than one slice (which gives wrong values for
1366 pixels which have saturated the hi-gain) This was a problem
1367 mainly for timing studies, not so much for the automatic standard
1368 analysis. Also the values for the Spline have been changed slightly:
1369 + Digital Filter from 1.70 to 0.95
1370 + Spline from 1.39 to 1.30
1371 The numbers were sorted out by an extensive test in the
1372 test-database.
1373
1374 - callisto: Removed the tab showing the average calibrated arrival
1375 time. It never gave useful information.
1376
1377 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1378 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1379 and both were extracted because the hi-gain was above the
1380 LoGainSwitch.
1381
1382 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1383 lo-gain pulse position (after application of LoGainOffset, which
1384 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1385 have saturated and both were extracted because the hi-gain was above
1386 the LoGainSwitch.
1387
1388 - callisto: After extensive tests a new threshold level for determination
1389 of the pulse position has been found at 50phe. This is due to the
1390 fact that for lower pulses the arrival time changes its average
1391 behaviour dramatically. It tends to the average of the extraction
1392 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1393
1394 - callisto: Added two more plots to the calibration part. The average
1395 extracted signal and the average extracted arrival time as
1396 extracted by the signal extractor (This can help debugging problems
1397 because it doesn't involve a fit)
1398
1399 - star: changed the fit for the effective on time such that initial
1400 values are calculated automatically now instead of using build
1401 in values. This makes the fit more indepedant of the underlaying
1402 rates. With a test of ~350 sequences in the test database it could
1403 be shown that the new fit gives the same result +/-1sek.
1404 The highest deviation was +5s the lowest -10s. You can now control
1405 the bahaviour with two resource values:
1406 MHEffectiveOnTime.FistBin: 3
1407 MHEffectiveOnTime.NumEvents: 12000
1408 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1409 from the resulting gamma candidates
1410
1411 - star: The Center histogram in MHHillas is now by default displayed
1412 with the colz draw-option
1413
1414 - ganymed: now produces valid error codes if failed
1415
1416 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1417 with the option "hadronness" instead of "area" or "both" if
1418 you want to use both cuts. The hadronness cut includes a fixed
1419 cut in hadronness (index 8) and a fixed cut in size (index 9).
1420
1421 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1422 the M3Long of the anti source to be not properly evaluated
1423 (actually is was evaluated as a unique random number) in case
1424 of optimization with anti-theta cut switched on. This might have
1425 lead to improper, but not necessarily wrong, optimization results.
1426
1427 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1428 how to use random forest
1429
1430 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1431 ganymed_onoff.rc. Seems to be unintentional that they were different.
1432
1433 - sponde: Since the introduction of the possibility to define a
1434 normalization energy instead of using the integral the default
1435 was not using the integral anymore but a normalization energy of
1436 1GeV. It is now the integral again.
1437
1438 - sponde: Fixed a problem in the weighting which did not allow
1439 a MC slope of -1.
1440
1441
1442
1443 *** Version 0.9.6 (2006/05/24)
1444
1445 - general: changed the binning of the azimuthal profile of the camera
1446 such that it is aligned with the 60deg boundaries.
1447
1448 - merpp: better handling of problems with the TH, TD part of the
1449 CC-REPORT for files older than 200507190 and 200412210
1450 respectively
1451
1452 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1453
1454 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1455
1456 - callisto: if an arrival time is extracted outside the fadc range is
1457 was set to the boundary before. Now a random number is assigned
1458 instead to avoid unfortunate coincidences of arrival times just
1459 by this arbitrary value.
1460
1461 - callisto: added a new option to callisto.rc which allows
1462 to set the maximum arrival time difference allowed for the
1463 badpixel algorithm to determin whether a pixels belongs to a shower:
1464 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1465
1466 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1467 to 0.9 as suggested by Stefan due to a recent study on the fraction
1468 of pixels surviving the image cleaning
1469
1470 - callisto: switched off error in case of "pulse is too much to the left"
1471
1472 - callisto: The extraction window is not adapted anymore. This means that
1473 the pulse is extracted from the full range. The draw-back is that the
1474 background (pedestal) will become slightly higher. Switching on/off
1475 the PulsePosCheck in the callisto.rc only effects filling the
1476 histograms.
1477 WARNING: If the pulse is too much to the left data is calibrated!
1478 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1479 in the database to make sure that your data is valid!
1480
1481 - star: Show also the number of stars correlated correctly by the
1482 starguider
1483
1484 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1485 than one off-source region in wobble-mode. To use it add the following to
1486 your ganymed_wobble.rc:
1487 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1488 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1489 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1490 + Cut1.ThetaCut: None
1491 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1492
1493 - ganymed: in the case the latest report is older than a default (currently
1494 one minute) and the current report will be skip the starguider
1495 correction and calibration will be reset. The maximum age can be
1496 setup from ganymed.rc by (minutes):
1497 MPointingDevCalc.MaxAge: 1.5
1498
1499 - ganymed: A first implementation showing all size-bins for the theta-sq
1500 resp. alpha-plots in a single tab automatically
1501
1502
1503
1504 *** Version 0.9.5.1 (2006/05/05)
1505
1506 - general: Added a new option "zdiff" to the Makefile which runs
1507 "cvs diff" as "make diff" would do, but with compression
1508
1509 - general: accelerated MTFillMatrix (used for eample in all training
1510 and optimization macros) by skipping some obsolete calles in the
1511 eventloop the first and second loop could be accelerated by ~20%
1512
1513 - general: Added a missing feature in the MFilterList class which
1514 prevented MFEnergySlope from working correctly in trainenergy.C
1515
1516 - general: Accelerated the random forest training and usage a bit
1517
1518 - merpp: Adapted to new raw data file format version 6
1519
1520 - merpp: fixed a problem with reading the starguider reports
1521 after 6.3.2006
1522
1523 - callisto: At some times six pixels had to be exchanged manually in the
1524 data. If the pixels to be swaped are both not found, an error was raised
1525 and calibration was stopped. Now it is assumed they are intentially not
1526 mapped and the Error has been changed to a Warning.
1527
1528 - star: Added new image cleaning based on the arrival time of the shower.
1529 The new cleaning can be accessed using the parameter "Time" instead of
1530 the the old one (like "Absolute) in the star.rc-file.
1531 Recommended parameters:
1532 + MImgCleanStd.CleanLevel1: 8.2
1533 + MImgCleanStd.CleanLevel2: 5
1534 + MImgCleanStd.CleanRings: 2
1535 + MImgCleanStd.KeepSinglePixels: No
1536
1537 - star: Simplified the calculation of the effective on time. By letting
1538 the fit start in the third bin the result should become more stable.
1539 The fit quality is now ignored for the theta-plot which is not used
1540 in the analysis later. Still better pre-cut which, for example,
1541 remove events triggered by car-light (rate changing on a short
1542 time-scale) are missing.
1543
1544 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1545 for optimization (kWeakSource) which is suggested by the Berlin
1546 people for weak sources.
1547
1548 - macros: plotdb.C:
1549 + if no dataset and no time-interval is given only sequences with
1550 an effective on-time above five minutes are plotted anymore
1551 + added a new tab "RelTime" displaying the relative on-time
1552 (effective on-time divided by the observation time)
1553
1554 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1555 the optimization became a lot faster
1556
1557 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1558 To display them just delete the pads displayed on top.
1559
1560 - ganymed: fixed a bug which could cause strange behaviour in wobble
1561 mode if no starguider information was available due to an incorrect
1562 initialization of the starguider calibration
1563
1564 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1565 be changed from within the plot. It can also be setup from the
1566 resource file using:
1567 + MHDisp.fScaleMin: 0.325
1568 + MHDisp.fScaleMax: 0.475
1569
1570 - ganymed, showplot: Fixed a problem with the fit to the off-data
1571 (HistOff) which could cause a time lag or an inifinite loop.
1572 The bug did not effect the results at all.
1573
1574 - sponde: Added a new tab showing the effective collection area after
1575 trigger (including the software trigger)
1576
1577 - sponde: MMcSpectrumWeight has a new option which allows to define
1578 the scaling factor not by the integral of the events but at
1579 a defined energy:
1580 e.g. MMcSpectrumWeight.NormEnergy: 200
1581
1582 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1583 eventloops the loop could be accelerated by ~20%
1584
1585
1586
1587 *** Version 0.9.5 (2006/03/13)
1588
1589 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1590 and added the standard Disp-parametrization
1591
1592 - macros: added a new macro datacenter/macros/plotstat.C allowing
1593 to plot statistics about the data processing
1594
1595 - macros: added a new macro to plot the muon correction coefficients
1596 versus period (macros/plot/mucal.C)
1597
1598 - showplot: path inflation for ganymed files was broken
1599
1600 - callisto: Fixed an important bug. When the number of saturating pixels
1601 were calculated the bad pixel information already available from the
1602 calibration was ignored. This yields wrong values in case pixels
1603 are broken and saturate all the time or randomly.
1604
1605 - callisto: Updated Muon calibration constants. Spline data now also uses
1606 different values for different periods
1607
1608 - star: The time-evolution shown in the effective on-time plot now displays
1609 the axis range (if there are no holes it should be similar to the
1610 effective on-time)
1611
1612 - star: Added two new image parameters:
1613 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1614 the three pixels next to the center of gravity and the size
1615 + MNewImagePar.fConcCore: The ratio of the signals of all
1616 pixels inside or touching the ellipse and the size
1617
1618 - ganymed: now stops in requested source isn't found in catalog file
1619
1620 - ganymed: Many improvements to the phi-plot in wobble mode:
1621 + with a template the ideal background is displayed
1622 + a possible camera inhomogeneity is taken into account
1623 + the anti theta cut is better supported
1624 + the phi cut is automatically calculated from the theta cut
1625 See the examples in ganymed_wobble.rc for more details.
1626
1627 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1628 times the bin-width instead of the absolute energy
1629
1630 - ganymed: New cuts for on/off and wobble mode
1631
1632 - ganymed: The smearing of the False Source plot has been increased
1633 to 0.06
1634
1635 - ganymed: The starguider calibration can now be changed from the
1636 resource file.
1637 See the examples in ganymed*.rc for more details.
1638
1639 - ganymed: added a new option for on-/off-observations
1640 MJCut.RandomSourcePosition
1641 If switched on the distribution of observation time of the source
1642 position in the camera is calculated from the on-data and randomly
1643 applied with this distrbution to the off-data.
1644
1645 - ganymed: by skipping some obsolete calles in the eventloop the
1646 first and second loop could be accelerated by ~20%
1647
1648 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1649 position in the off-data randomly according to its distribution in the
1650 on-data.
1651
1652
1653
1654 *** Version 0.9.4.3 (2006/02/13)
1655
1656 - general: Fixed a bug in most of the programs which prevented the
1657 compile date in the startup message to be displayed
1658
1659 - general: Simplified program calls. The following abbreviations
1660 are now possible:
1661 showlog callisto 55599
1662 showplot signal 55599
1663 star 55599
1664 callisto 55999
1665 ganymed 2
1666 In this cases the corrsponding root-, log-, sequence- or dataset-
1667 filename is automatically compiled using the default datacenter
1668 paths ("/magic/*")
1669
1670 - general: Fixed a long outstanding bug which made axis tick marks
1671 disappear if MDataFormula was used (eg. abs(x))
1672
1673 - general: Updated MMath with new functions to calculate the results of
1674 a exponential, logarithmic and powerlaw fits analytically.
1675
1676 - general: Updated some macros with comments:
1677 + macros/optim/optimdisp.C
1678 + macros/optim/optimenergy.C
1679 + macros/optim/optimwobble.C:
1680
1681 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1682 files) now allows adding a pre-cut like in the optimization. E.g. this
1683 is useful to perform g/h-separation cuts before training the random
1684 forest.
1685
1686 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1687 correctly assigned in the raw data assignement table. A fix to correct
1688 the assignment tabel have been implemented.
1689
1690 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1691 by 90, 180 and 270 deg.
1692
1693 - general: the macro plotdb.C now allows to highlight sequences belonging
1694 to a datset. For more details see the descritions in the macro.
1695
1696 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1697 of the display, it gave wrong results espacially for big sizes.
1698 Now the embedded canvas should always have a ratio width/height=3/2.
1699 The "Size" options have been updated with values fitting the 3/2
1700 size ratio.
1701
1702 - RanForest:
1703 + Updated the random forest classes to support also the
1704 regression method implemented by Thomas H.
1705 + added new tutorial macro how to train the random forest
1706 for energy estimation (macros/optim/rfenergyest.C)
1707 + new classes to train the random forest (still in development)
1708 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1709 + new tutorial macros for random forest training in macros/train
1710 trainenergy.C, traindisp.C, trainseparation.C
1711
1712 - mars: now allows to setup a cut in the resource file mars.rc to choose
1713 the events to be displayed, eg:
1714 Cut.Condition: {0} && {1}
1715 Cut.0: MHillas.fSize>100
1716 Cut.1: MHillas.fSize<900
1717
1718 - merpp: Made aware of the new .rep format 200510250. This includes
1719 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1720 the discriminator thresholds (MCameraTD) and the disciminator
1721 delays (MCameraTD). All of them come with the CC report and are therefor
1722 written to the CC tree.
1723
1724 - callisto: fixed a bug in the calculation of the arrival times in
1725 the Digital Filter. They were all shifted by the same amount
1726 fHiGainFirst. This caused an offset in the order of the position of
1727 the left border of the extraction window in the times calculated
1728 from high-gain and from low-gain. The bug effected only the absolute
1729 arrival times. The bug was there since 30.1.2005.
1730
1731 - callisto: Changed the ExtractionWindow for the pulse position check
1732 such that the camera inhomogeneity becomes as less as possible and
1733 comparable to the pulso position check switched off. More details
1734 on the study will be given at our result web-page.
1735
1736 - ganymed: ganymed.rc, ganymed_onoff.rc:
1737 changed to new cuts trained with 1ES1218 and Crab-data
1738 for maximum sigma*log10(excess)
1739
1740 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1741 a new option was implemented to estimate Disp (CalcDisp)
1742
1743 - ganymed: Implemented two new options which allow
1744 to overwrite the default path to search for the sequence files
1745 --ins=/magic/sequences
1746 and where to search for the image data
1747 --ind=/magic/data/star
1748
1749 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1750 dx/dy from the resource file by
1751 MSrcPosCorrect.Dx
1752 MSrcPosCorrect.Dy
1753
1754 - ganymed: fixed reading the source catalog. Only as many chars
1755 as the requested source name had were compared (If a source
1756 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1757 were requested it could happen that the coordinates of
1758 "1ES1218" were read) The source coordinates are now printed
1759 in addition to its name to the logging output.
1760
1761 - ganymed: changed the background fit in the case of a ThetaSq function
1762 from a polynomial to a exponential, this should give a big improvement
1763 for on-only analysis'
1764
1765 - ganymed/sponde: Calculation of the error of single size-/energy-
1766 bins now uses Li/Ma (5) instead of LiMa (17)
1767
1768 - sponde: Added a plot E^2*dN/dE
1769
1770 - sponde: The energy estimator plot should now show values like
1771 they are commonly used.
1772
1773 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1774 (a powerlaw with cutoff didn't work before)
1775
1776
1777
1778 *** Version 0.9.4.2 (2005/10/01)
1779
1780 - general: added new tutorial macro macros/tutorials/threshold.C:
1781 how to calculate the threshold
1782
1783 - general: added a new game. Start it from the interpreter with
1784 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1785 and MagicReversi)
1786
1787 - general: neighbor pixels in MGeoms are now sorted clockwise
1788
1789 - merpp: made aware of new format 20050829-0
1790
1791 - callisto: New scale factors from muon analysis, stored in new
1792 resource file resources/calibration.rc
1793
1794 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1795 the eventloop if something went wrong. This is necessary for the
1796 automatic processing
1797
1798 - callisto: Implemented a new treatment for the time information
1799 developed by S.Ruegamer, this should give much better response than
1800 the old very primitive algorithm. This is especially important
1801 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1802 treatment was buggy! As neighbor pixels to interpolate the
1803 arrival times always the pixels 0 to 5 were taken)
1804
1805 - callisto: In addition to the new treatment of arrival times the
1806 decision of the treatment whether a pixel contains shower
1807 information or not is used to improve the signal interpolation
1808 further. Previously interpolated pixels showed a non-zero signal
1809 do the peak searching signal extractors. Having a signal pixel
1810 beside raised the signal above the cleaning level. Thus the
1811 pixel survived cleaning to often but with a too low mean signal.
1812 By replacing empty pixels with a gaus (mean and rms from the
1813 corresponding Area entries in MPedPhotCam) this effect can
1814 be supressed.
1815
1816 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1817 got lost when the events were stored by the calibration... fixed.
1818 (This was no problem for normal image cleaning because the pixel
1819 content was artificially set to 0 not surviving standard cleaning
1820 algorithm)
1821
1822 - callisto: Fixed a bug which caused the random and peak-search pedestal
1823 extracted with an extractor to be exchanged for the first (roughly)
1824 500 events (*Extractor and *ExtractorRndm).
1825 (They were simply exchanged in callisto.cc) This bug might have been
1826 introduced in Mars 0.9.4 when the order of calculation of the two
1827 types of pedestal in callisto got exchanged. The bug only effects
1828 the first seconds of data of each sequence.
1829
1830 - star: Taking the arrival time of Muons into account the calculation
1831 of the parameters could be made independant of the noise
1832 (pedestal rms). The dependance was due to the bias of the peak search
1833 extractor. Now only a ZA dependamcy is left which is not yet fully
1834 understood.
1835
1836 - ganymed: The sequences were still not sorted correctly in any case,
1837 because they were sorted by the full qualified path name. Now they
1838 are sorted by their sequence number.
1839
1840 - ganymed: new values for the spark-event-cut
1841
1842 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1843
1844
1845
1846 *** Version 0.9.4.1 (2005/08/18)
1847
1848 - callisto: fixed some problems with the calibration in case of
1849 inteleaved events. Therefor the final and some intermediate
1850 fits are skipped which would take place on partly filled #
1851 histograms and gave wrong results or failed completely.
1852
1853 - callisto: If the intermediate finalization of the histograms
1854 calculating the mean charge of the calibration signal fails
1855 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1856
1857 - ganymed: Fixed some bugs which caused problems in On-only mode.
1858 Still the false source plot doesn't give reasonable results.
1859
1860
1861
1862 *** Version 0.9.4 (2005/08/05)
1863
1864 - general: Fixed the ZA binning. It did not correctly fit the
1865 MC binning
1866
1867 - general: Added a class to correct for the missfocussing in
1868 April (MSrcPosCorrect)
1869
1870 - general: Random Forest energy estimator should now work properly
1871
1872 - general: MHCamera now displays the profiles in deg instead of mm
1873
1874 - general: MH::SetPalette offers a lot of new palettes
1875
1876 - general: MHillas - the case of CorrXY==0 is now handled properly
1877
1878 - general: implemented the possibility to change the line and
1879 marker style of a sky-grid drawn by MAstroCatalog
1880
1881 - general: Runs in sequences and datasets are now automatically
1882 ordered (it is assumed that the order of their filenames correctly
1883 represents the order of observations) to ensure correct reading
1884 of the subsystem data
1885
1886 - general: Runs cannot be added to a sequence twice anymore. Also
1887 Sequences cannot be added twice anymore to a dataset.
1888
1889 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1890 It gave wrong results by 1./2pi
1891
1892 - showplot: got a new option to start a root interpreter, too
1893
1894 - mars: now displays a rough estimate of Disp and the third moment
1895
1896 - mars: now displays the event time MTime if available
1897
1898 - mars: show muon parameters graphically
1899
1900 - mars: now the file to open can be given as commandline
1901 argument
1902
1903 - merpp: Added support for new arehucas version >= 200507190
1904 implementing values for three temperature sensors in the
1905 counting house (MCameraAUX) and the name of the HV settings file
1906 (MCameraHV).
1907
1908 - merrp: Also fixed some problems with wrong versions numbers stated
1909 by arehucas and implemented some fixed for old versions (<200407070)
1910
1911 - callisto: MCalibrationHiLoCam can now be printed from its context
1912 menu, eg in the TBrowser
1913
1914 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1915 - 1.39 (MExtractTimeAndChargeSpline)
1916 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1917 This is important mainly for timing studies.
1918
1919 - callisto: Changed limits in MHCalibrationChargeCalc from
1920 - -100.125 to -98 (fgChargeHiGainFirst)
1921 - 1899.875 to 1902. (fgChargeHiGainLast)
1922 - -100.25 to -99 (fgChargeLoGainFirst)
1923 - 899.75 to 901. (fgChargeLoGainLast)
1924 Introduced new limits:
1925 - fgNumLoGainBlackoutLimit: 0.05
1926 - fgLoGainBlackoutLimit: 3.5
1927 - fgLoGainPickupLimit: 3.5
1928
1929 - callisto: The handling of automatic weights for the digital filter
1930 has been improved. There are now new calibration weights special
1931 for Monte Carlo calibrations.
1932
1933 - callisto: Updated Muon scale with latest results (1% difference
1934 for most data, 5% for Mar/Apr'05)
1935
1936 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1937 was saturated and the blackout-events in the low-gain exceed the
1938 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1939 This excludes those pixels which have a saturating high-gain
1940 channel, but the low-gain switch does not switch often enough
1941 to make the distribution reliable.
1942
1943 - callisto: fix a bug counting the number of saturated events. Up to now,
1944 the number of saturated slices was counted (which is one for a not too
1945 high number), but for some (pathological) pixels, many more slices
1946 saturated and produced wrong limits.
1947
1948 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1949 + MCalibrationRelTimeCam.CheckFitResults: Yes
1950 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1951 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1952 + MCalibrationRelTimeCam.CheckOscillations: Yes
1953
1954 - callisto: introduce max. number of events for intercalibration,
1955 the rest gets skipped. Default: 4096
1956 The calibration causes too many un-reliable pixels if more
1957 than about 5000 events are treated (@500 Hz) because of the
1958 mode hopping of the VCSels. However, in the past, some
1959 calibration runs have been taken (erroneously) with more
1960 than 5000 events, especially the intensity scans where
1961 a good precision is needed.
1962
1963 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1964 photo-electrons for the spline extractor by 1-2% (correctly).
1965
1966 - callisto: The intercalibration is now done using a full f-factor
1967 method instead of a simple update. This makes things slower but
1968 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1969 changes.
1970
1971 - callisto: MPedestalY3 now uses the same extraction range as the data
1972 as calculated by MPedestalY2
1973
1974 - callisto: A check of the fraction of allowed unsuitable (10%) and
1975 unreliable (30%) pixels has been addded when the conversion is
1976 calculated from interleaved events
1977
1978 - star: fixed a bug which caused MEffectiveOnTime containers not to
1979 be written. In the worst case they were skipped almost all, in the
1980 best case they were all ok. It depends on how often the new value
1981 was assigned just with an event which was skipped later by another
1982 task
1983
1984 - star: new histograms MHPointing and MHRate
1985
1986 - star: New tab (Currents) displaying the time evolution of the mean
1987 DC currents
1988
1989 - star: New tab (MeanRms) displaying the time volution of the mean
1990 Pedestal Rms
1991
1992 - star: Output now contains MReportStarguider
1993
1994 - star: Improved muon analysis. Due to the absense of a constant
1995 for the gaus fit for arc width and the fact that the arcwidth
1996 plot was a histogram instead of a profile the resulting psf
1997 became pedestal rms dependant
1998
1999 - ganymed: added new plot (MHPhi) for wobble mode as described in
2000 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2001
2002 - ganymed: corrects now (correctly?) for the misspointing in
2003 May/April 05
2004
2005 - ganymed: Two new default templates for ganymed.rc are avilable:
2006 ganymed_onoff.rc and ganymed_wobble.rc
2007
2008 - ganymed: The first version of MFMagicCuts has been released
2009
2010 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2011
2012 - ganymed, sponde: There are two new options to determin the number
2013 of bins for the signal region (NumBinsSignal) and the number of
2014 total bins (NumBinsTotal) in the MHThetaSq histogram
2015
2016 - ganymed: optimized palettes for MHDisp
2017
2018 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2019 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2020 sqrt(2) to large
2021
2022 - ganymed: The false source plot (MHDisp) is now based on Disp
2023 and a background model determined in the first loop is
2024 subtracted
2025
2026 - ganymed: MFMagicCuts are now available in the cvs. The correct
2027 solution for the disp ambiguity problem is now calculated using
2028 the third moment. The third moment cut therefor is skipped.
2029
2030 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2031 already determined by the third moment along the major axis and
2032 so its actual sign is aligned along the major axis of the shower.
2033
2034 - ganymed: If starguider data is available it is taken into account
2035 when calculating the source position. This is especially important
2036 for wobble data at high zenith angles and culmination data.
2037
2038 - ganymed: If available the starguider data is taken into account as
2039 good as it is possible without a starguider calibration. To switch
2040 it off add
2041 MPointingDevCalc.MaxAbsDev: -1
2042 to your ganymed.rc
2043
2044 - sponde: the zenith angle distribution is now weighted instead of
2045 choosen by default. This gurantees higher statistics in the highest
2046 and lowest energy bins. To switch this behaviour off use...
2047
2048 - sponde: now automatically displays the energy threshold
2049
2050
2051
2052 *** Version 0.9.3 (2005/06/03)
2053
2054 - general: MMcEvt now derived from MMcEvtBasic which should
2055 have no influence on compatibility with older camera files
2056
2057 - general: Implemented a new option to MReadReports which allows
2058 to force reading of the first event of some trees (eg. Drive-tree)
2059 before any other tree.
2060
2061 - general: Made a fix to MPointingPosCalc which assumes that the
2062 run-type is real-data if Process is called before ReInit, such
2063 that also the very first Drive-events in a run are treated
2064 correctly.
2065
2066 - shoplot now displays the filename in the title bar of the window
2067
2068 - merpp: new options: --auto-time-start --auto-time-stop which
2069 allow to cut updating with slow-control at the start- or
2070 (previousle --auto-time only allowed: and) stop-time of
2071 the run stored in the runheader.
2072
2073 - callisto: changed default of fgFallTimeHiGain in
2074 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2075 already set as default in callisto_Dec04Jan05.rc
2076
2077 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2078 now changes the filename for new weights automatically for
2079 cosmics, MC and for different calibration colors.
2080
2081 - callisto: a problem with the order of some code cause the
2082 name of the weights file in MPedestalY2 to be ignored.
2083 Wrongly the calibration_UV weights were used instead
2084 of the cosmics weights set in callisto.rc.
2085
2086 - callisto: should allow ct1 pulser data when the color is
2087 explicitly set also for pretty new runs
2088
2089 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2090 to introduce an additional scale factor (should be around 1)
2091 to adapt for slight deviations in different extractors from
2092 the MC calibration. For MC calibrations the scale factor
2093 is fixed to 1
2094
2095 - callisto: MFCosmics should handle very high signals a bit
2096 more accurate now
2097
2098 - callisto: when calculating the mean pedestal rms for different
2099 pixel sizes or sectors also kUnsuitableEvt is now taken into
2100 account - not only kUnsuitableRun
2101
2102 - callisto: '-raw' option is now the default
2103
2104 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2105 This has the advantage that mean values in the calibration (eg
2106 arrival times) are calculated more accuratly.
2107
2108 - callisto: In the resource file callisto_Dec04Jan05.rc
2109 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2110
2111 - callisto: new Hi-/Lo-Gain intercalibration constants
2112 hilocalib_sp1.root and hilocalib_sp1_mc.root
2113
2114 - callisto: changed default for MJPedestalY2.MaxEvents
2115 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2116
2117 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2118 has changed from 9.0 to 6.0. This is necessary to exclude two very
2119 ringing pixels in September which - when kept - destroy the image
2120 cleaning around them (Markus G.)
2121
2122 - callisto: (!) The Muon analysis of all data taken so far has
2123 suggested that different extractors give slightly different
2124 absolute results after calibration, due to there different
2125 handling of the calibration- and cosmics pulse shape. Although
2126 the over all calibration seems to be a bit to pesimistic (or
2127 the MC seems to be a little bit - 3-5% - too much attenuated).
2128 There for correction factors have been introduced which correct
2129 the calibration constants by
2130 0.956937799 for Digital Filter (callisto.rc)
2131 and
2132 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2133 calibration. The main advantage is, that both data types can
2134 be easily analysed together and compared to the same MC sample.
2135 The factors are choosen such, that the reference is now a
2136 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2137
2138 - star: fixed a bug which caused the first bin of the histograms
2139 vs time to disapear in PostProcess. This gave wrong results
2140 on the screen. The output and all following programs not
2141 directly accessing the histograms haven't been affected
2142
2143 - star, ganymed: Made sure that always the first Drive-tree event
2144 is read and Processed before the first data event was read.
2145
2146 - ganymed: implemented the possibility to replace the standard
2147 false source plot with a different one. For example: If
2148 you want to use a Disp based FS plot use the resource:
2149 NameHistFS: MHDisp
2150 For details about the requirements of these plots look
2151 at the corresponding classes
2152
2153 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2154 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2155 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2156 case MAlphaFitter is setup correctly. For On-Only optimization
2157 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2158 RunOn() instead of Run(). For energy estimation MJOptimize
2159 has been replaced by MJOptimizeEnergy
2160
2161 - sponde: The input MC spectrum can now be weighted to fake a
2162 different spectrum. This is done via MMcSpectrumWeight. For
2163 more details see the class description and sponde.rc
2164
2165 - sponde: The paremeter comparsion plots are not scaled by
2166 their entries anymore. Instead the MC plot is scaled by using
2167 the result spectrum of the analysis. If the input MC spectrum
2168 and the result spectrum has different slopes the absolut
2169 normalization is normally wrong.
2170
2171
2172
2173 *** Version 0.9.2 (2005/05/20)
2174
2175 - general: Changed the default paths for calibrated data and image
2176 files. (The implemented access to these files doesn't yet exist)
2177
2178 - general: support for MRunIter has been removed from the job classes
2179 (use the setter functions of MSeqeunce instead)
2180
2181 - general: ProcessFile has been renamed to Process in all job classes,
2182 because ProcessFile is missleading
2183
2184 - general: The storage of the palette in MHCamera is now possible
2185
2186 - general: new bits describing unsuitable and unreliable pixels have
2187 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2188 kDeadPedestalRms, kFluctuatingArrivalTimes
2189
2190 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2191 versions newer than V200404070
2192
2193 - general: support for cc file versions newer than V200504130. Added
2194 support for active loads (MCameraActiveLoad) and central pixel
2195 (MCameraCentralPixel)
2196
2197 - general: added new histograms for image parameters versus size
2198 (MHVsSize)
2199
2200 - general: The eventloop now automatically calls PrintStatistics
2201
2202 - Status Display: Improved support for printing:
2203 + A default can now be set in .rootrc (for more details see
2204 MStatusDisplay::PrintPS)
2205 + A print dialog is opened so that printer and command line
2206 can be canged
2207
2208 - showlog: improved such that it handles different verbosity levels
2209 more accurate now. This mean you can suppress output when
2210 using showlog.
2211
2212 - showplot: improved
2213 + The new graphics formats have been implemented
2214 (pdf, svg, png, jpg and xpm)
2215 + Implemented an interface for printing. Because you can change
2216 the printing command from the command line you can use all
2217 the nice postscript tool. To print a booklet for example call:
2218 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2219 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2220 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2221
2222 - callisto: fixed a bug in the recognition of the calibration bit
2223 pattern. Concerns only intensity calibration. (The strength of the
2224 intensity has been updated in some cases)
2225
2226 - callisto: add a filter against PIN Diode events when running over
2227 calibration runs since some of the recent calibration runs have
2228 been taken with Pin Diode.
2229
2230 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2231 39943, 44833 in the calibration (MCalibColorSet)
2232
2233 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2234 been set to 1e-18 in callisto_Dec04_Jan05.rc
2235
2236 - callisto: in callisto_Dec04Jan05.rc: set value for
2237 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2238 statistics for the calculation of the mean pulse time
2239 of the cosmisc
2240
2241 - callisto: the charge limit in the calibration has been raised
2242 from 2.5 to 4.5
2243
2244 - callisto: new setup read from callisto.rc
2245 + MCalibCalcFromPast.fNumEventsDump
2246 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2247 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2248
2249 - callisto: MExtractTimeAndChargeSpline extractor:
2250 + The integration ranges were shifted by 0.2 FADC slices to the right.
2251 + unreliable handling of floating point values caused different
2252 results on different platform or with different compiler options:
2253 The new algorithm is numerically exact and more accurate because
2254 it doesn't calculate the integration position by multiple times
2255 adding the step-size (which results in numerical uncertanties
2256 exspecially if multiplied with large numbers)
2257 + A lot of fixes have been introduced which effects integrating the
2258 spline at the edges of the valid range. In this case any memory
2259 was randomly accessed. This behaviour can be tested replacing
2260 all MArrayF by TArrayF which perform a range check (but of course
2261 they are a lot slower)
2262 ! No result obtained with the Spline before can be trusted! Due to
2263 random memory access it might by completely random!
2264
2265 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2266 + extraction range in the high gain to 4.
2267 + weights file to cosmics_weights46.dat
2268
2269 - callisto:
2270 + introduce the check for fluctuating arrival times.
2271 + set charge limit to from 2.5 to 4.5
2272 + introduce asymmetric exclusion due to "deviating number of phes":
2273 Default: -9.0 +4.5
2274 + make deviating number of phes unsuitable (see David's findings).
2275
2276 - callisto: fixed the display of unsuitable pixels. The old change
2277 to a real profile in MHCamera broke it.
2278
2279 - callisto: The cosmics filter is used in MJCalibration now
2280 independant of the pulser color (formaly it was used only for
2281 CT1-pulser data). The threshold of number of max empty pixels
2282 has been raised from 2% to 5% in MJCalibration. The maximum
2283 fraction of rejected event is 50% otherwise the calibration has
2284 failed. The filter now ignores unsuitable pixels.
2285 Setup the filter from callisto.rc using "ContCosmics"
2286 (see MFCosmics::ReadEnv)
2287
2288 - callisto: changed default for fgOffsetFromLogain back
2289 from -2.8 to -1.8 in digital filter.
2290
2291 - callisto: for the common extractors
2292 + MExtractFixedWindow
2293 * MExtractTimeAndChargeSlidingWindow
2294 * MExtractTimeAndChargeSpline
2295 * MExtractTimeAndChargeDigitalFilter
2296 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2297 and fResolutionPerPheLoGain
2298
2299 - callisto: Updated the hi-/lo-gain intercalibration constants
2300 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2301 hilocalib_df6.root
2302
2303 - callisto: The default lo-gain extraction window for the
2304 MExtractTimeAndChargeSlidingWindow extractor has been increased
2305 from 6 to 8 to take the stretch of the pusle into account
2306
2307 - callisto (!!!): fixed an important bug in the setting of the
2308 incoming pedestal pointer to the signal extractor extracting
2309 pedestals. This bug caused the pedestals not to be subtracted
2310 correctly in the calibration afterwards. The effect was about 10%
2311 too high conversion factors for the digital filter and the spline
2312 and more than 40% for the sliding window.
2313 The bug existed since end of February! (Markus G.)
2314
2315 - star: added muon support to star. A new tab "MHMuonPar" is
2316 displayed. The lower right plot is an estimate of the point spread
2317 function. A reference value is displayed. To get the real PSF
2318 you must compare with MC. The setup for the muon analysis
2319 is done in star.rc. More informations can be found in
2320 MHSingleMuon and MHCalibParCalc
2321
2322 - star: The weather data is now displayed in star
2323
2324 - star: MEventRateCalc handles the calculation of the event rate more
2325 accurate now in case of the start of a new run inside a sequence
2326
2327 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2328 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2329 changed only minimally
2330
2331 - ganymed: (MJCut and MJOptimize) now displayes the number of
2332 excess events versus size. The energy estimation is done in
2333 MJSpectrum (sponde)
2334
2335 - ganymed: got support for using other variables than Alpha, eg. Theta.
2336 Therefor you need a class deriving from MHAlpha which supports
2337 this variable (one is already existing: MHTheta, which is now the
2338 default in ganymed). It is setup through ganymed.rc
2339
2340 - added a full featured spectrum program (sponde) which reads
2341 ganymed output and monte carlos and compiles a spectrum
2342
2343
2344
2345 *** Version 0.9.1 (2005/04/14)
2346
2347 - Fix bug on the arrival time reconstruction when using Digital
2348 Filter (in some marginal cases (10%) times were reconstructed shifted
2349 by 0.2 slices)
2350
2351 - all executables now return 2 where in previous versions -1 has
2352 been returned (gave problems with shell-scripts)
2353
2354 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2355 also done with a intercalibration input file
2356
2357 - a bug in the time fine adjustment of the digital filter has been fixed
2358
2359 - a lot of small fixes to calling TPad::Divide with a margin==0
2360
2361 - MStatusDisplay now shows the memory usage
2362
2363 - added a memory leak statistic after the eventloop
2364
2365 - MHadronness replaced by MParameterD
2366
2367 - MEnergyEst replaced by MParameterD
2368
2369 - wobble mode can now be switched on from the data-set
2370
2371 - switched on bad pixel detection for a pedestal level
2372 which is more than 5 times the variance
2373
2374 - Fixed default paths to be correct for the new data center
2375
2376 - Fixed handling of drive data. The pointing position in now
2377 copied to MPointingPos inside star for real and MC events
2378
2379 - made sure, that the sequences in a dataset are sorted by
2380 their number to ensure the correct synchronization
2381
2382 - added all resource files necessary to handle spline extraction
2383 of signal for the late 2004 and the early 2005 data
2384
2385 - update the reference lines for the december data
2386
2387 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2388 This is important for the Dec. and Jan. data where the calibration
2389 pulse position changes much.
2390
2391 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2392 filter. This corrects only an defective extraction of the MC at
2393 low-gain signals lower than 90 phes.
2394
2395 - fixed some slowdown in calibrating data with interleaved events from
2396 Jan and Dec. As a workaround made the pretty palette the default.
2397 The inverse Deep Blue Sea has a bug which slows down long calibration
2398 runs a lot.
2399
2400 - implemented new values from new starguider report as defined
2401 in TDAS00-07 V7.1 (eg SkyBrighness)
2402
2403 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2404 in starguider report (If you merpp the same reports with this version
2405 you'll get the correct units (arcmin) but a different result
2406 than with old versions (wrong units))
2407
2408 - Now the status display can also write PNG, JPEG and XPM (other file
2409 formats are still unsupported by root)
2410
2411 - added a lot of scripts and macros in directory datacenter used
2412 for automatic processing
2413
2414
2415
2416 *** Version 0.9 (2005/03/23)
2417
2418 - Calibration is now done autmatically into photo-electrons like
2419 decided by the Collaboration Board
2420
2421 - Reference lines in the display can be read from resource file
2422
2423 - Interlaced calibration events can be handled by callisto
2424
2425 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2426 and applied in callisto.
2427
2428 - class MJCalibTest can be called by callisto
2429
2430 - callisto can now run with three data types: rawdata, rootdata, MC
2431
2432 - added two classes mreport/MReportStarguider.cc and
2433 mreport/MReportStarguider.h for implementing starguider-data
2434
2435 - the output of merpp-update now contains starguider information:
2436 MReportStarguider and MTimeStarguider
2437
2438 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2439 values were lower than they should. This was more visible for high
2440 energy (Size) events.
2441
2442 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2443
2444 - added a new loop to callisto to support the correct extraction of
2445 the pedestal and pedestal rms through the signal extractor
2446
2447 - added class to perform fourier tranformation of a hexagonal structure
2448 (MHexagonalFT)
2449
2450 - added class to perform fourier tranformation of a hexagonal structure
2451 in a tasklist (MHexagonalFTCalc) example: hft.C
2452
2453 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2454 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2455 small pixels, example: extendcam.C
2456
2457 - added possibility to write data to memory (TTree) using MWriteRootFile
2458
2459 - added possibility to read a TTree stored only in memory by MReadTree
2460
2461 - new classes to deal with the interleaved calibration events:
2462 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2463
2464 - implemented filters to callisto to skip calibration events
2465
2466 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2467 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2468 the slices by statistics
2469 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2470 signal extractor without randomization
2471 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2472 with the signal extractor with randomization (extraction window is
2473 randomly fixed)
2474 The three kind of pedestal is not yet implemented (for speed reasons) as
2475 long as nobody really needs it:
2476 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2477 extracted with the signal extractor with randomization
2478
2479 - callisto now finds the pulse position in the data automatically
2480
2481 - implemented data reduction in calibrated data by reducing the precision
2482 of the stored floating point values (pedestal, rms and signal) to
2483 roughly 0.5%
2484
2485 - fixed showplot to make file format conversion (eg. converting a
2486 status display stored in a root file into a postscript file) in
2487 batch mode possible:
2488 showplot -b --save-as-ps[=outfile.ps] infile.root
2489
2490 - Allow class names as part of filter rules, eg
2491 (MFSupercuts) && (MHillas.fSize>100)
2492
2493 - fixed a lot of stuff to allow all programs to process MonteCarlo
2494 camera files.
2495
2496 - enhanced possibility to debug reading of resource file
2497
2498 - MDataChain should handle priorities of operator more
2499 accurate now
2500
2501 - completely revised the container in which the signal is stored
2502 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2503 * the new implementation is faster and
2504 * needs less storage space
2505
2506 - FIRST version which can process Monte Carlos through the
2507 whole chain of programs (callisto, star, etc)
2508
2509 - implemented new image parameters for the border length of
2510 the shower image (MNewImagePar2)
2511
2512 - implemented wobble-mode in ganymed
2513
2514 - new class (MJOptimize) taking care of all optimization processes
2515
2516
2517
2518 *** Version 0.8.6 (2004/10/05)
2519
2520 - New combined signal and time extractor
2521 MExtractTimeAndChargeDigitalFilter
2522
2523 - The Report for the trigger section in the CC run summary has been
2524 updated, and now the IPRs (Individual Pixel Rates) are available.
2525
2526 - new macros for database interaction: filldotrun.C, filldotrbk.C
2527
2528 - added new program which can convert colored output which was redirected
2529 into a file back into colored text (for example to display it with
2530 more): showlog
2531
2532 - added new program to display an MStatusArray of plots (stored with
2533 MStatusDisplay) from a file: showplot
2534
2535 - Added support for Sequences (MSequence). Sequences are blocks of run
2536 files containing the same calibration and belonging to the same
2537 source
2538
2539 - Added a new task (MTaskEnv) which can be used in setup files to switch
2540 between different tasks (for example to choose a signal extractor)
2541
2542 - Implemented automatic file splitting in MWriteRootFile
2543
2544 - After image cleaning an island index is assigned to all used pixels.
2545 The index corresponds to the order of the islands in size.
2546
2547 - added a cleaning which takes signal height _and_ arrival time into
2548 account: probability cleaning (for more details see MImgCleanStd)
2549
2550 - added a cleaning which takes takes the absolute number of photons
2551 times the area ratio as cleaning level
2552 (for more details see MImgCleanStd)
2553
2554 - Changed calculation of image parameters such, that it can be done
2555 for all used pixels or the pixels with a defined island index only
2556
2557 - implemented new image parameters displaying the number of islands,
2558 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2559
2560 - event display in executable changed to support also calibrated files
2561 (done with MJCalibrateSignal)
2562
2563 - added program doing the calibration and the signal extraction
2564 and signal calibration: callisto Most part of the setup is done
2565 by a resource file: callisto.rc
2566
2567 - implemented support for pixels with negative IDs (Raw file format
2568 version 4)
2569
2570 - implemented an new option in merpp (--auto-time) to get the time
2571 range for cc and/or caco data from the run header of the raw data
2572
2573 - New star-program (star and MJStar). Taking calibrated data from
2574 callisto/MJCalibrateSignal as input. The setup is done through
2575 a resource file: star.rc
2576
2577 - Added possibility to setup the eventloop in the mars-executable
2578 Camera Display by a resource file: mars.rc
2579
2580 - The the mars-executable Camera Display can now also read
2581 calibrated data files written by callisto/MJCalibrateSignal
2582
2583 - Added a new class which can calculate the source position in
2584 the camera from a pointing model known to be correct and
2585 the pointing model used for observations (MSrcPosFromModel)
2586
2587 - added a new version of the class calculating the effective on-time
2588 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2589 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2590 MHTimeDiffTheta.
2591
2592 - added the possibility to count how often a signal is above (or
2593 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2594 can replace MHTriggerLvl0)
2595
2596 - added ore convinient ways to set the axis-titles of your histograms
2597 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2598 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2599
2600
2601
2602 *** Version 0.8.5 (2004/08/06)
2603
2604 - new Signal Extractors: MExtractFixedWindowSpline
2605 and MExtractAmplitudeSpline
2606
2607 - implementes interleave in merpp to be able to merpp parts of a file
2608
2609 - implemented force-functionality to merpp
2610
2611 - star display to display star catalogs (MAstroCatalog)
2612
2613 - star display to 'mirror' stars to the camera (MAstroCamera)
2614
2615 - implemented a new cleaning option which allows cleaning scaled with
2616 the real ratio of the rms depending on the pixel size, not only the
2617 square root of the pixelsize (MImgCleanStd, MCameraData)
2618
2619 - removed obsolete MBlind* classes
2620
2621 - Signal extractor taking the AB flag into account implemented (this makes
2622 an odd number of slices for signal extraction possible
2623 (MExtractSignalABcorr)
2624
2625 - implemented a class extracting the pedestal from the raw-data (events)
2626 itself using empty lo-gain (MpedCalcFromLoGain)
2627
2628 - Added mean values to MPedPhotCam
2629
2630 - Added Makefile for Darwin (this OS is NOT officially supported!)
2631
2632
2633
2634 *** Version 0.8.4 (2004/04/19)
2635
2636 - new fast arrival time extractor using cubic splines:
2637 MExtractTimeFastSpline
2638
2639 - implementes multi-argument support in MDataChain
2640 ("pow(a, b)")
2641
2642 - implemented double reference support in MDataChain
2643 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2644
2645 - added support in MF for expressiond like
2646 "MHillas.fWidth<2*<MHillas.fLength"
2647
2648 - MDataChain is now able to support variables like [0], [1], ...
2649 which can be used in fit functions as parameters. The interface
2650 is implemented through the new virtual function
2651 MParContainer::SetVariables
2652
2653 - added new class MArrivalTimeCam/MArrivalTimePix:
2654 Storage containers to hold the ArrivalTime of the camera/pixel
2655
2656 - added new classes for the calibration of relative arrival times:
2657 MCalibrationRelTimePix and MCalibrationRelTimeCam
2658
2659 - added new classes to extract the signal of the blind pixel and the
2660 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2661
2662 - added new classes for the bad-pixels treatment (MBadPixels*)
2663 which are more powerfull than the old ones (MBlindPixel*)
2664 and will replace them.
2665
2666 - added filter against cosmics: MFCosmics
2667
2668 - added new class MArrivalTimeCalc2:
2669 Calculates the arrival time as the signal weighted mean of the time
2670 slices in the maximum window
2671
2672 - added a new macro call pointspreadfucntion.C that fits with a 2D
2673 gaussian the DC spot for an star. It gives you the RMS of
2674 the PSF and the center of the star, very useful for misspointing
2675 studies.
2676
2677 - added support for multi-telescope camera files. Added classes
2678 MStereoCalc and MStereoPar, classes to calculate and store shower
2679 parameters calculated from the data of two telescopes, for the MC
2680 studies regarding the MAGIC clone.
2681
2682 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2683 MC data calibrated in photons instead of ADC counts.
2684
2685 - added three macros to show the calibration and analysis chain of
2686 MC data. The macro starmc.C does both calibration and analysis, producing
2687 an output containing Hillas parameters for each event. The macro
2688 mccalibrate.C does just the calibration and writes out a file containing
2689 pixel information in photons instead of FADC data. The macro starmc2.C
2690 reads in such a file and produces an output with Hillas parameters.
2691
2692 - added MPedPhotCalc to compute pedestals in units of photons, see
2693 macro pedphotcalc.C
2694
2695 - added all class to perform the calibration, see macro calibration.C
2696
2697 - added class MFFT to perform Fast Fourier Transforms
2698
2699 - added class MSimulatedAnnealing to perform simulated annealing
2700 minimizations
2701
2702 - added new macro bootcampstandardanalysis.C which holds the skeleton
2703 of the analysis chain discussed in the december bootcamp.
2704
2705 - added support for DAQ raw data file format V2
2706
2707 - implemented an arbitrary time stamp for the events from raw-data
2708 files with file version<3. It is calculated from the run number,
2709 the date of start and the FADC clock tick from the first module
2710
2711 - implemented the correct decoding of the event time-stamp
2712 coming from the DAQ for raw-data files with file-version>2
2713
2714 - added a new classes storing the pedestals in units of photons:
2715 MPedPhotPix, MPedPhotCam
2716
2717 - added support for DC current files from the camera control
2718
2719 - added support for start- and stop-time when merpping report files
2720
2721 - added MReportCC storing the weather data from the CC-REPORT
2722
2723 - added class to fill trainings and test matrices (MTFillMatrix)
2724
2725 - added a filter performing a software trigger (MFSoftwareTrigger)
2726
2727 - Added classes to perform parts of the standard analysis (Jobs):
2728 + MJPedestals
2729 + MJCalibration
2730 + MJExtractSignal
2731 Note: All of them are preliminary!
2732
2733 - Added Iterator to iterate over files giving only the run-number
2734
2735 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2736 the evolution of a sector vs time
2737
2738
2739
2740 *** Version 0.8.3 (2003/12/05)
2741
2742 - adapted Random Forest classes to allow the use with MC
2743 multi-telescope files which can be produced with the coming
2744 camera version 0.7.
2745
2746 - added classes to read and interprete central control report files
2747 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2748
2749 - enhanced merpp (the executable) to support .raw and .rep files.
2750
2751 - added classes for light calibration (MCalibration* and
2752 MHCalibration*) by Markus Gaug. Further work has to be and will
2753 be done soon.
2754
2755 - Added a preliminary 'synchronizer' (MReadReports) which will
2756 replace MReadMarsFile as soon as it is finished.
2757
2758 - Added a tutorial macro demonstrating how report files are merpped
2759 and how they can be read from the root file in the correct order
2760 of time (readrep.C)
2761
2762 - Added a generalized histogram (similar to MH3) called MVsTime
2763 which allows to plot variables (or rules - MDataChain - of
2764 variables) vs time. For an example have a look at tempvstime.C.
2765
2766 - Changed the name of the event trees:
2767 + Events --> Events
2768 + PedEvents --> Pedestals
2769 + CalEvents --> Calibration
2770
2771 - changed name of MTime in the event trees from MRawEvtTime to MTime
2772
2773 - added displaying the sector indices to the mars event display
2774
2775 - Magic Online Analysis (MOnA) implemented in a first version
2776 (see mona.cc, MOnlineDump and MOnlineDisplay)
2777
2778 - added classes to calculate event rate
2779 (preliminary: MEventRateCalc, MEventRate)
2780
2781 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2782
2783 - added classes dealing with the telescope pointing position (MPointing*)
2784
2785 - implemented the 'final' Mars time stamp based on some experiences with
2786 the new 'Synchonizer'
2787
2788
2789
2790 *** Version 0.8.2 (2003/11/10)
2791
2792 - accelerated standard analysis by a factor of 6-8 ...
2793 + doing precalculations in MGeomCam for the pixel area ratio
2794 + creating a look up table for the single pixels in MCerPhotEvt
2795
2796 - added task to calculates weights in case you want to 'change'
2797 the energy spectrum of a monte carlo file
2798 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2799
2800 - added a new executable star which implements the
2801 star.C macro as precompiled executable. Currently a flexible
2802 setup is not possible, but a 'input card' setup will follow.
2803
2804 - Starting to implement Multi-Telescope-Support based on the
2805 upcomming camera version 0.7. The base for a general support
2806 is implemented and the star-functionality is proven to work.
2807
2808 - Replaced Event-Display in and Camera-Display in the Mars GUI
2809 executable by a more convinient display base on MStatusDisplay.
2810
2811 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2812
2813
2814
2815 *** Version 0.8.1 (2003/10/20)
2816
2817 - added signal subtraction for pure on data by means of fitting
2818 the background in the off region or by performing a combined
2819 signal/background fit. Provides necessary histograms for
2820 obtaining energy spectra and a light curve.
2821
2822 - added classes to perform and study the selection of the
2823 2nd Level Trigger on MC data (example in triglvl2.C macro)
2824
2825 - added pedestal calculation
2826
2827 - implemented "democratic cleaning" (tail cut value proportional
2828 to pixel area) according to Wolfgang's suggestion.
2829
2830 - added Sigmabar treatment (calculation and basic histogramming)
2831
2832 - added basic routines to apply padding
2833
2834 - added first implementation of MARS-based source visibility plotter
2835 (needs to be linked against slalib, preliminary version)
2836
2837 - enhanced functionality of data chains: random numbers, conversion
2838 functions and access to MHMatrix objects
2839
2840 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2841 numbers under certain circumstances (runs with 0 events included)
2842
2843 - fixed a bug in the general filter MF (didn't work on some systems
2844 at all)
2845
2846 - fixed a bug in chaining files, which caused the analysis to crash or
2847 ignore files
2848
2849 - implemented more geometry classes describing the parameters used
2850 to simulate the PMT camera
2851
2852 - added new Monte Carlo classes containing the setup of the different
2853 programs in the MC chain.
2854
2855 - added a (preliminary) general task to evaluate chi-square of a given
2856 parameter in an eventloop.
2857
2858 - first implementation of a container describing the observatory
2859 location (Long, Lat, etc)
2860
2861 - added Random Forest - method for g/h-separation
2862
2863 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2864 (this means, that it is compiling, but not yet fully tested)
2865
2866 - added a new status display which can show the present status
2867 of histograms while an eventloop is running (MStatusDisplay,
2868 an example can be found at status.C)
2869
2870 - reorganized directories:
2871 classes describing the image --> mimage
2872 classes containing Monte Carlo Histograms --> mhistmc
2873 classes for Random Forest method --> mranforest
2874
2875 - added (event-)weights to fill histograms
2876
2877 - colors in logging output to screen
2878
2879 - changes to the Image Parameter declaration:
2880 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2881 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2882 + MHillasExt now derives from MParContainer instead of MHillas
2883 --> Files written with the old definition are more or less unreadable
2884
2885 - reading of reflector files
2886
2887 - display data from reflector files in the camera
2888
2889 - implemented currents (and display them in the camera)
2890
2891 - logarithmic scale in camera
2892
2893 - added class to iterate through directory contents (MDirIter)
2894
2895
2896
2897 *** Version 0.8 (2002/11/18)
2898
2899 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2900
2901 - corrected 48(!) wrong entries in the Next Neighbor table of the
2902 Magic Camera (all in the inner part of the outer ring, mostly
2903 missing a single NN)
2904
2905 - Fixed a bug in the table describing the Next Neighbours of the
2906 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2907 have any neighbour)
2908
2909 - changed trigrate.C: now it calculates the pure NSB triggers from
2910 a camera file (generated with no showers), so there is no need
2911 to introduce them by hand in the BgR array (for more details
2912 please ask Abelardo)
2913
2914 - added MHHadronness (and MHadronness) as a general facility to evaluate
2915 the quality of a gamma-hadron seperation method
2916
2917 - changed MWriteAsciiFile to accept rules (MDataChain)
2918
2919 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2920 must be replaced by calles to MWriteAsciiFile::AddColumn and
2921 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2922 changed.
2923
2924 - Implemented generalized event-matrices (one row per event)
2925 (MHMatrix)
2926
2927 - implemented the one dimensional composite probabilities
2928 (MHCompProb, MCompProbCalc, comprob.C)
2929
2930 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2931 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2932
2933 - Added a camera display displaying the pixel numbers to the
2934 event display gui.
2935
2936 - Added Monte Carlo Informations to event display gui
2937
2938 - Changed the camera display to display the pixel numbering
2939
2940 - Added three buttons to the camera display to change the palette
2941
2942 - Added the number of used and core pixels after image cleaning
2943 to MHillas
2944
2945 - Changed the algorithm used in MHillas according to TDAS 02-03
2946
2947 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2948
2949 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2950
2951 - Added fCosDeltaAlpha to MHillasSrc
2952
2953 - The numbers of photons used to calculate fConc and fConc1 in
2954 MHillasExt are now scaled with the pixel size, so that one get
2955 a four times smaller value for the bigger pixels in the outer ring.
2956
2957 - added new task to smooth the camera contents (MCameraSmooth)
2958
2959 - added possibility to use interpolated pixel values for blind pixels
2960 instead of removing it completely from the analysis
2961
2962 - Implemented the possibility to save the whole eventloop with
2963 its setup to a file. This information can be read and from
2964 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2965 and MEvtLoop::MakeMacro. If you find something not working, please
2966 report - this stuff is still in a beta phase.
2967
2968 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2969 file having crab starfield, but also for all following files - fixed
2970
2971 - MTaskList::PrintStatistics can now be instructud to print also the
2972 title, too: use PrintStatistics(0, kTRUE)
2973
2974 - Changed the image cleaning so that pixels with to many 'used'
2975 neighbors are left used (to get rid of 'holes' in events)
2976
2977 - Introduced more output to the camera displays
2978
2979 - Added an array of histograms (eg one hist per run), MHArray
2980
2981 - Added a _preliminary_ version of the reader for CT1 PreProc files
2982 (MCT1ReadPreProc)
2983
2984 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
2985 (thanks to Raquel)
2986
2987 - added the first energy estimator (MEnergyEstParam, estimate.C,
2988 estfit.C) using a parametrization
2989
2990 - Added some new Monte Carlo paremeter containers used to store
2991 setup information from the MC chain (MMcConfigRunHeader,
2992 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
2993
2994
2995
2996 *** Version 0.7 (2002/04/30)
2997
2998 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
2999 the pedestal mean value was saved incorrectly. For files from
3000 this versions we substract 0.5 from the pedestal mean.
3001 WARNING: This may effect your results, so don't wonder...
3002
3003 - First implementation of an algorithm using only triggered events
3004 for the collection area calculation
3005
3006 - Ascii Output can now also be used for parameter containers which
3007 doesn't overload MParCointainer::AsciiWrite
3008
3009 - The Ascii Output is now also capable of writing single data members
3010 of one container
3011
3012 - You are now able to change the order of the values written to the
3013 ascii file
3014
3015 - You can now specify a conversion factor for each data member written
3016 to an ascii file. This may be usefull to change the units of the
3017 data member (eg. degrees instead of millimeters in case of the
3018 hillas parameters)
3019
3020 - Replaced old MHillas by a new structure which allows you to extend
3021 the parameters stored in MHillas very easily:
3022 see MHillas and MHillasExt
3023
3024 - Added classes to handle source dependancy of image parameters:
3025 see MHillasSrc
3026
3027 - Added container (MBinning) to have a standard input for the binning
3028 in different histograms (eg. the Energy bins should be the same in
3029 all histograms)
3030
3031 - Changed Hillas histograms from mm to deg
3032
3033 - Added the flexible binning to the hillas histograms
3034
3035 - Added a filter for the alpha parameter (MFAlpha)
3036
3037 - It is now possible to write single data members of a class object to
3038 an output stream instead of the whole container only
3039
3040 - Added a generalized filter for a data member:
3041 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3042
3043 - Added a generalized Filter parser for more difficult filter rules
3044 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3045
3046 - Added new Monte Carlo histograms:
3047 MHMcEnergyImpact and MHMcEfficiency
3048
3049 - Added many new histograms needed for the flux calculation.
3050
3051 - Added a generalized histograms which can fill and show up to three
3052 data members in either a one-, two- or three-dimensional histogram, eg:
3053 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3054
3055 - Added:
3056 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3057 * calculation of <Theta> as a function of time (MHThetabarTime)
3058 they are needed in the flux calculation in
3059 order to select for a given bin in Theta (or time) the appropriate
3060 effective collection area, which is assumed to be given as a function
3061 of Theta and the true energy
3062
3063 - Added calculation of the migration matrix in the energy
3064 (MHMcEnergyMigration):
3065 the migration matrix describes the migration from the true (E_true)
3066 to the estimated energy (E_est); it is needed to determine the
3067 distribution of E_true from the measured distribution of E_est
3068 by unfolding
3069
3070 - changed the color palette in the camera display to DeapSea.
3071
3072
3073
3074 *** Version 0.6 (2002/01/15)
3075
3076 - Introduce the option of disable pixels (MBlindPixels and
3077 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3078 able to deal with Star Field NSB.
3079
3080 - Fixed a bug in the pedestals substraction
3081
3082 - Introduced verbosity levels
3083
3084 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3085
3086 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3087 work correctly (thanks to Abelardo)
3088
3089 - Introduced correct treatment of the diffuse Night Sky Background
3090 and NSB (MMcPedestalNSB)
3091
3092 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3093
3094 - Introduced MMcRunHeaders which contains monte carlo run informations
3095
3096 - Added a 'Print'-Task (MPrint) which calls the Print function
3097 of a parameter container for each event
3098
3099 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3100
3101 - changes to be more efficient with root 3.02/06
3102
3103 - root 3.02/06 fixes:
3104 + the memory leak when reading MRawEvtData
3105 + loosing more time than necessary to update the progress bar
3106
3107 - MWriteAsciiFile is now capable of writing more than one container
3108 in a line. For example: To be able to write Monte Carlo and
3109 Hillas values (energy and alpha) in one line.
3110
3111
3112
3113 *** Version 0.5 (2001/11/06)
3114
3115 - Added new GUI functionality (Analysis)
3116
3117 - Added a camera display to be able to display events in the camera
3118 together with the calculated hillas ellipse
3119
3120 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3121 object at any state of the analysis, so that the output are several
3122 states
3123
3124 - Fixed a bug in the collection area error calculation
3125 (Thanks to Ciro and Abelardo)
3126
3127 - Fixed a bug which causes merpp to crash in some environments
3128
3129 - Implemented auto enabling scheme for Branches to speed up reading
3130 a lot (see MReadTree and MTask)
3131
3132 - Fixed a bug in the Histogram classes which caused histograms to
3133 be written to a file by MWriteRootFile without request
3134
3135 - changed the object I/O from the old stylish root I/O to the new
3136 'auto evolution scheme' This was done only for classes which are not
3137 yet used in Monte Carlo files, so that these files are still readable.
3138
3139 - Added support for a progress bar in MEvtLoop and MReadTree
3140 (see the Analysis Window in Mars for an example)
3141
3142 - Fixed a bug in the package creation which disturbed the conversion
3143 between a mars version unpacked from a tar file and the repository.
3144
3145 - Changed the code to writer merpped (converted into root format)
3146 raw files, to get faster (around 10%)
3147
3148
3149
3150 *** Version 0.4 (2001/09/20)
3151
3152 - This release is made to compile on a root version >= 3.00
3153
3154 - Fixed a bug which causes MReadTree to read the first file only
3155
3156 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3157
3158 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3159
3160 - Added a task to write several container to a root file (MWriteRootFile)
3161
3162 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3163
3164 - Added calculation of the collection area (MMcCollectionAreaCalc)
3165
3166 - fixed some bugs in the Hillas calculation
3167
3168 - added filters to be able to control the task execution dependent on
3169 a parameter (for example: the number of level 1 triggers in a MC-file)
3170
3171
3172
3173 *** Version 0.3 (2001/04/23)
3174
3175 - Many demo macros added
3176
3177 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3178
3179 - Hillas Calculation added
3180
3181 - Standard image cleaning available
3182
3183 - MReadTree is now able to handle more than one file
3184 (Remark: of the same structure)
3185
3186 - Now we are able to display events in a first version of the
3187 Camera event display. To do this we must run the macro
3188 "macros/readCT1.C" to read data from CT1.
3189
3190
3191
3192 *** Version 0.2 (2001/01/24)
3193
3194 - First Implementation of a Gui to read the raw data. Start the
3195 gui with the command mars.
3196
3197
3198
3199 *** Version 0.1 (2000/12/20)
3200
3201 - First official release 0.1
3202
3203 - Changes:
3204
3205 + changed calling style of MRawPixelIterator from do...while to
3206 while-loop
Note: See TracBrowser for help on using the repository browser.