source: trunk/MagicSoft/Mars/NEWS@ 9366

Last change on this file since 9366 was 9359, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 131.2 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * There is no need to re-run any data because no change took place which
8 could have an effect on the output. However, if you want a
9 meaningful SrcPos plot for your MCs in sponde you must re-process
10 star for your MCs first.
11
12 ;general
13
14 * fixed a few small bugs which could cause the display to crash in ganymed
15 and sponde
16
17 * in sequence file the date can now be omittet. In this case the
18 leading date with the underscore is missing in the expected filename
19
20 ;automation
21
22 * added magnetic field Azimuth direction (ARRANG), currently
23 at ~ -7deg at La Palma
24
25
26 ;database
27
28 * plotdb.php: added default (sequences) for startup, added possibility
29 to set size of plot
30
31 ;merpp
32
33 * added support for Arehucas Version >= 200812140
34
35 ;mars
36
37 * The display now also displays the trigger pattern
38
39 * The display can now display ceres reflector (_R_) files
40
41 ;ceres
42
43 * added a uniformly distributed one-bin time jitter for the start of the
44 digitization. Otherwise the first photon would be digitized always with
45 the same alignment to the bins
46
47 * Added a plot showing the production height of the photons
48
49 * Moved the particle id from the event header to the run header
50
51 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
52
53 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
54
55 * Added many new options to control the tasks. For deatils see ''ceres.rc''
56
57 * Removed obsolete plots in pedestal and calibration mode
58
59 * Removed the non-NightSky photons from the plots where they are just
60 disturbing
61
62 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
63
64 * The daq event number now represents the readout number
65
66 * The camera ''electronics'' can now be ''switched off''
67
68 * A new tab ''Info'' now display basic things like the reflector
69 layout
70
71 * Improved reading speed for corsika files
72
73 * Improved memory handling (if a large ampount of memory was needed
74 for a single event all further events were stored in the same
75 memory and it was never freed, so the program took this memory
76 until the end)
77
78 * Converted the code from MMCS' reflector program to MSimAtmosphere
79 (instead of the tables build in for MAGIC Winter and Summer
80 atmosphere we use the values written by Corsika fitted to the
81 tabulated atmosphere given as input)
82
83 * For caluclating the displayed image parameters in ceres a basic
84 image cleaning removing isolated pixels is now done.
85
86 * The magnetic field direction (ARRANG) is now taken into account
87
88 * Added plot for the energy threshold after trigger ''Threshold''
89
90 * Added plot for the effective collection area after trigger ''TrigArea''
91
92 ;star
93
94 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
95
96 ;sponde
97
98 * The SrcPos plot for your MCs was so far meaningless because it just
99 displayes the MSrcPosCam data from the input star-files. Unfortunately,
100 this containes was never written to the star-files yet.
101
102 * A new Tab 'OnTime' is available which is an effective on-time
103 fit as in star but for all data. This is mainly for manual cross-check
104 of the effective on-time
105
106 * In some circumstances it might be necessary to re-calculate the
107 eff. on-time from the fit in the new tab, e.g. when a zenith distance
108 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
109
110 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
111 it to its own output file (for convinience)
112
113
114
115== Version 2.2 (2009/01/30) ==
116
117 ;SUGGESTION
118
119 * This release doesn't contain a major change which is expected to
120 change your results. Nevertheless there are small changes to
121 the calibration which can effect at least the first few hundred
122 events in any (mainly MUX and even more SUM) sequence a little bit.
123 So it is recommended although not necessary to reset your sequences
124 in the database before further processing.
125
126 ;NEW
127
128 * A first implementation of a Monte Carlo simulation program
129 (ceres - Camera Electronics and REflector Simulation) has been
130 implemented. It can simulate a full telescope already including
131 a complete reflector simulation and a flexible trigger and readout
132 simulation. Currently, no perfect setup is implemented and
133 especially the output of the program (data structure) should
134 be considered alpha state. Also the user interface is not yet
135 ready.
136
137 ;general
138
139 * All command line options after -- are now interpreted as
140 arguments (usually everything which doesn't start with a minus)
141 rather than options (usually everything which starts with a
142 minus). This allows to use file names starting with a -
143
144 * In all resource files you can now initialize the random number
145 generator. For details see: MJob::InitRandomNumberGenerator
146
147 * added a new program called ''readcorsika''. It's purpose is (in analogy
148 to readraw and readdaq) to read a Corsika output file (for now
149 only cherenkov output is supported) and print its contents in a
150 human readable form. It can also write the contents of this file
151 into a root-file.
152
153 * The calculation of the maximum distance to the origin in a MGeomCam
154 has been improved (edges might be further away than the sides).
155 This is just a tiny change but it might change the appearance of
156 the radial profiles a little bit.
157
158 * The default binning of the center-of-gravity plot has slightly been
159 increased
160
161 ;Database
162
163 * Added informations about the DC currents (fMinCurrents, fMedCurrents
164 and fMaxCurrents). The values are retrieved from the plots showing
165 the average DC currents of all pixels versus time.
166
167 * Websites with tables have now the opportunity to remove lines
168 ('-' button at beginning of each line) and get all lines back
169 ('+' at top of the column)
170
171 * Websites: added option to query only sequences containing sumtrigger
172 events
173
174 * Websites: added option to group by date (year, month, night) for runs
175 and sequences and enabled that combining of different group-bys,
176 e.g. status, date and source is possible
177
178 ;automatic analyis
179
180 * Rewritten producing plots in the web.
181 New plots, namely the output of plotoptical.C (extinction curve from
182 KVA), plotstat.C (status of the automatic analysis (percentage of
183 processed, analysed data etc.)) and plotusage.C (statistics of the
184 condor usage in the data center) has been are available now next to the
185 plots of plotdb.C
186 Mean values from the plots (output of the macro) are provided in a
187 txt file now.
188 The creation of the plots for callisto, star and ganymed in the web is
189 now steered via database. Consequently the plots are faster and
190 reliable up-to-date.
191 For all plots, a new layout is available facilitating the browsing
192 through the plots and providing additional information on the
193 displayed values. (tabs.php) These plots are linked from the DB
194 websites and the wiki.
195
196 ;statusdisplay
197
198 * The ''Loop'' entry in the menu bar now contains an option to pause
199 the loop and to process single events.
200
201 ;merpp
202
203 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
204 instead of RunHeaders)
205
206 * Now allows to merpp files newer than 2008/09/03.
207
208 * Added fixes for wrong (wrong or double) run- and file-numbers
209 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
210
211 ;callisto
212
213 * Extracting the pulse position for the pulse position check events
214 with sum trigger were denied. This decreased the statistics
215 extremely and therefor the resulting puse position was calculated
216 quite weak. Now sum events pass the calculation if and only if they
217 have also a level 1 trigger.
218
219 * the extraction of pedestal events and pulse position from the
220 first data events is now more automatic and makes sure that
221 a more precise number of events is extracted independent of
222 the ratio with which pedestal events or events with signals
223 are contained in the data.
224
225 * Updated Muon calibration constants for all MUX data (teh changes were
226 all smaller than 5%)
227
228 ;star
229
230 * For the calculation of the effective on time all sum-triggered events
231 were skipped. Now all Level1-triggeres events will pass. This might
232 result in a slight inaccuracy of the effective on time.
233
234 ;ganymed
235
236 * If the source position is more than 1deg away from the camera
237 center an error is raised now.
238
239 * Hopefully fixed the bug ''ganymed crashes when resized''
240
241 ;sponde
242
243 * Fixed a problem which causes the fitted spectral slope to be displayed
244 incorrectly. If you use MJSpectrum::FormFlux in your macros make
245 sure that the parameter 0 of your fit is negative.
246
247 * Added a histogram showing the read source position of your MCs
248
249
250
251== Version 2.1.1 (2008/08/04) ==
252
253 ;Database
254
255 * Added the median number of photo electrons from the calibration
256 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
257 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
258
259 * Added fTotOnTime, which is the on-time as given by the run-headers
260 (in contradiction to fAbsOnTime which comes from CC)
261
262 * Added new primaries for the new data structure (Magic II): for the
263 tables dealing with sequences (SequenceBuild Status, Sequences,
264 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
265 this is the telescope number (fTelescopeNumber) for the tables dealing
266 with runs (RunData and RunProcessStatus) this is in addition the file
267 number (fFileNumber)
268
269 * Added column fPriority to the status tables to be able to steer the order
270 in which the data is processed. As default the run, sequence and dataset
271 number are used.
272
273 ;automatic analyis
274
275 * Adapted scripts to the new data structure: They can handle now different
276 telescopes (getting the information as usual from the database).
277 The paths for Magic 2 are not yet implemented.
278
279 ;general
280
281 * should work now with root 5.20/00 (please note that root 5.20/00
282 we encounter crahses in the status display which are ot yet
283 understood)
284
285 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
286 instead of the base name of the file. This makes them easier to
287 access from the code
288
289 * Default Monte Carlo names in MSequence do not require the _E at
290 the end anymore
291
292 * where abrrevating a sequence file with a sequence number is possible
293 also "telescope:sequence" is now accepted, e.g.:
294 star 2:2000123 --out=output
295 see the programs' help for more details.
296
297 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
298 from the database. See the constructors for more details.
299
300 * MReadTree now supports friends
301
302 * MReadTree can now read also files not written by MARS and store
303 the data encapsulated in emulated MParContainers
304
305 * added a new starguider calibration valid since 15.1.08
306
307 ;showplot
308
309 * showplot can now read more than one file at once. This is especially
310 inetersting if reading files containing pure canvases
311
312 ;merpp
313
314 * we merpp the dc currents now also from the camera reports (they have
315 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
316
317 * In the automatic analysis we omit merpping of the currents from the
318 caco files and use the lower rate camera reports from the cc files
319 instead
320
321 * merpp has been redisigned to allow merpping of the cc-reports
322 of a whole sequence. This allows to design a very simple analysis:
323 mkdir output
324 ./callisto 100776 --out=output
325 ./merpp 100776 output
326 ./star 100776 --ind=output --out=output
327 Instead of the sequence number also sequence files are accepted.
328
329 * Implemented a fix for run-numbers between 1001348 and 1001396
330 which were incorrectly assigned by the cc.
331
332
333 ;callisto
334
335 * added a filter again which was was removed in the last release.
336 it removed the most brightest events. This should not change
337 any analysis result because these events are so bright that
338 they cannot be analysed anyway, but the bad-pixel plots doesn't
339 show outliers.
340
341 * updated muon calibration constants for the periods 51-57,
342 58-63 and 67-
343
344 ;star
345
346 * The camera currents are now displayed with the rate of the camera
347 reports instead of the caco reports
348
349 ;ganymed
350
351 * if mc camera files are new enough (>=8) the source position in the
352 camera is now calculated from the stored telscope and shower
353 orientation (Note, that this might not be suitable in all cases
354 depending on the aim of the study. These case still needs
355 implementation)
356
357
358
359== Version 2.1 (2008/06/18) ==
360
361 ;Database
362
363 * introduced average temperature and wind speed from star-files
364
365 * introduced average values from Pyrometer (mainly Cloudiness)
366
367 * introduced the ratio of accepted calibration events in the
368 calibration run
369
370 * introduced the average rates of the different trigger pattern,
371 e.g. the rate of pedestal and calibration events, from the signal-file
372
373 ;general
374
375 * fixed GroupBy options in plot*.C macros
376
377 * only display KVA points (not the Tuorla points) in plotoptical.C
378
379 * all programs now allow to add resources to the ones from the resource
380 file or overwrite them from the command line. This can be done like this
381 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
382 if something seems to be wrong you can debug what the program is doing
383 using the option --debug-env=3
384
385 * increased the diversity of debug levels. That also means that with -v3
386 you get now less output, i.e. only the output which is important for
387 an analysis. To get more output which helps for debugging try 4, 5 and 6.
388
389 * fixed a problem in the task synchronizing the reading of the reports
390 and the data stream. The effect was that in some circumstances the last
391 events of some trees could have been skipped. Since this is only a
392 very tiny part of the data no severe effect to your analysis results
393 is expected (an exception might be very short, i.e. singel runs,
394 datasets).
395
396 * Dataset file now allow to include the sequence file directly within
397 the dataset file and also allow to exclude single runs from the dataset.
398 (for more details see Class reference of MDataSet)
399
400 * Sequence files now allow for excluding runs from the analysis
401 (for more details see Class reference of MSequence)
402
403 * added code to process the sum-trigger flag
404
405 * the histogram classes MH3 and MHn now support profile histograms
406
407 * the histogram classes MH3 and MHn now support labels at the axis
408
409 * the Random Forest Train-classes (MJTRain*) now store the used datasets
410 in the output file
411
412 * the MFMagicCuts have a new option to allow a linear area cut (for
413 special studies)
414
415 * The liniking of the shared object is now done into a file defined
416 by 'mktemp'. This should be a local file system which accelerates
417 liniking a lot.
418
419 * The code has been prepared for compilation with root 5.18/00d
420
421 * The MHEnergyEst histogram now shows the distribution of
422 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
423 and (Eest-Emc)/Emc vs Emc.
424
425 * fixed mars (event display) for merpped raw-data and MC data
426
427 * adapted the synatx of sequence files to allow for the new run/file
428 scheme. For more details see class description of MSequence
429
430 ;showplot
431
432 * Added support for tiff files
433
434 * Added support for csv files (tables containing tab number,
435 name and title)
436
437 * Tabs now can have a title which is displayed in the postscript file
438
439 * When multiple file are written at once (e.g. pngs from a display)
440 it is now possible to use the tab name and or tab number in the
441 file name. For details see showplos's help.
442
443 ;merpp
444
445 * Implemented cc file version 2008-02-20/0
446
447 * Implemented cc file version 2008-05-19/0
448
449 * With new options merpping can be restricted (in addition to the
450 run-number) also by telescope and file number.
451 For details see "merpp --help"
452
453 * Implemented raw data format 11 (the most important change, except
454 from plenty of changes in the format definition, is the addition
455 of the file-number in the header) If nobody makes a mistake this
456 format should have the advantage that it is by definition forward
457 compatible, so old programs will be able to read newer formats.
458
459 * Added Pyrometer information to default output (stored in a new Tree
460 Pyrometer, needs a complete new merpp, i.e. new calibration)
461
462 * Merpping (also update) can now be restricted to one single report.
463 For example:
464 If you want to update an old file with Pyrometer information call
465 merpp --only=Pyrometer --update
466
467 ;callisto
468
469 * in the pedestal processing now at least 50 processed events are
470 required for succeeding.
471
472 * the signal and calib files now contain also the sequence information
473
474 * the two MPedestalCam in the calib file now have proper names
475 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
476
477 * Both pedestal cams now contain the number of events processed
478
479 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
480 i.e. for the extraction of the calibration pulses basically the average
481 over all events of the first slice instead of all slices was used.
482 Since pedestal and calibration constants are continously recalculated
483 this only effected the very first events of every sequence.
484
485 * For the extraction of the position of the maximum sample now the
486 extraction range is set automatically to the extraction window,
487 before the whole accessible range was used.
488
489 * If the number of samples in the events and the number of samples
490 in the run-header disagrees now an error is raised (this can
491 happen in not well simulated Monte Carlo files)
492
493 * In the case of MUX-data pedestal events with the lvl1 trigger flag
494 could survive into the pedestal calculation -- fixed.
495
496 * Tab "TrigPat" added showing the distribution of the trigger pattern
497 as found in the run-files (normalized with the run length)
498
499 * The selection of events from the trigger pattern has been improved.
500 If the trigger pattern is corrupted events won't pass anymore.
501
502 * Added a new command line option --dev-null to suppress output of
503 Y-files (this is useful for test cases)
504
505 * added a new tab "CalPos" showing the arrival time of extracted
506 interleaved calibration events
507
508 ;star
509
510 * the star file now contains also the sequence information
511
512 * Added a new command line option --dev-null to suppress output of
513 I-files (this is useful for test cases)
514
515 * Tab "Rate" added showing the distribution of the trigger pattern
516 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
517 the Y-files (normalized with the run length)
518
519 * The effective on-time calculation doesn't use events with only
520 sum-trigger anymore
521
522 * The data in the MHWeather tab has been reorganized. The never
523 working solar radiation has been removed and the data from
524 the pyrometer (cloudiness, air and sky temperature) is
525 displayed in addition.
526
527 ;ganymed/sponde
528
529 * Now data points are even shown correctly if they have error bars larger
530 than one sigma. Points with null or negative significances are omitted.
531
532 * DrawNicePlot now allows to set a projection range
533
534 * Updates pointing models. One is applied after the implementation
535 of the new LUTS in August, the other one is applied after the
536 next major change of the pointing model in October. Note that
537 these models are preliminary and give wrong results below Zd=65deg
538
539 ;sponde
540
541 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
542
543 * a new option "--force-runtime" is available. In case of very short
544 datasets (for light-curves) which are in the order of a few
545 minutes the calculated effective on-time is not very acurate because
546 it is quantizised in the order of a minute. Therefore you can switch
547 to using the real run-time instead (remakrt: this ignores any
548 dead-time!)
549
550 * a more analytical way is used to "fill" Monte Carlos into regions
551 of impact parameters which have not been simulated because the
552 trigger efficiency is assumed to be 0.
553
554 * estimated sensitivity curves for hi and lo zenith angles are shown
555 scaled to the correct observation time and collection area
556
557 * the Monte Carlo events after cuts are now written to the output file
558 if an output file given
559
560
561
562 *** Version 2.0 (2007/09/03)
563
564 - database: the position used for the pulse pos check was missing
565 in the callisto output and could thus not be filled into the DB.
566 Also the old values seemed not exactly the PulsePos used for
567 teh check.
568
569 - general: Resource file now allow an Include-Resource, i.e. you can
570 read a resource file with default settings, include it in your
571 resource file and overwrite the settings in your file. More than
572 one include file is allowed. Inclusions can be iterative.
573 Include: mydefaults.rc yourdefaults.rc
574 The resources in the first file have higher priority than the
575 second file.
576
577 - general: Now the output files (calib*.root, etc) also contain the
578 resource file (to check it open it in the TBrowser and choose Print()
579 from the context menu)
580
581 - general: Dataset files now allow to overwrite the default path
582 to search for sequence and data files. Note, that the program
583 option and individual resources will overwrite it. For example:
584 SequencePath: /magic/montecarlo/sequences
585 DataPath: /magic/montecarlo/star
586
587 - general: Fixed a problem with variables in MDataPhrase. It seems
588 that only optimdisp (didn't work) was effected.
589
590 - general: Some improvements to the optim and train processing. For
591 example the ststud window now got a proper title.
592
593 - general: The "Status Display: " was removed from the window title
594 within an Eventloop.
595
596 - general: added a new flexible histogram-class (MHn) which can be used
597 for example in testing after optimizations or training to produce
598 user defined histograms.
599
600 - general: The Random Forest now allows attaching an evaluation
601 function which is applied to its output. This allows to train
602 on whatever you like (eg. train on log10(energy), but return
603 energy)
604
605 - general: The Random Forest training of energy (trainenergy.c) and
606 disp (traindisp.C) has been improved by more graphical output to
607 judge the result.
608
609 - general: The training of energy (trainenergy.C) has been improved
610 a lot by training on a different quantity than energy. It gives
611 a result which is highly independant of the source spectrum
612 and shows lower bias than all other options.
613
614 - general: Dataset files are allowed to contain collections of
615 datasets. For more details see the class reference of MDataSet.
616
617 - general: The default WobbleMode in a datset file now (if not
618 overwritten) is "auto", i.e. wobble mode is set if the dataset
619 doesn't contain off-sequences.
620
621 - merpp: Merpp can read file format version 9 now. Please realize
622 that for file format version 9 the extraction range is different
623 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
624 the first and last 15 slices have been removed from all MUX data.
625
626 - mars: Similar to writing movies you can now select events which
627 should be displayed in your display. Therefore add the following
628 lines to your mars.rc:
629 MFEvtNumber.FileName: ganymed00223552.root
630 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
631 The input file can be a ganymed-file after (ganymed*.root) or
632 before (ganymed*-summary.root) file. For example to select all events
633 from your on sample after cuts (excluding the ThetaSq cut) use
634 MFEvtNumber.Selector: DataType.fVal>0.5
635 To show all events from your on-sample after quality cuts
636 use the summary file instead.
637
638 - mars: new ways to call mars are implemented. Instead
639 of calling
640 mars filename.root
641 you can now also use
642 mars sequence.txt
643 or
644 mars sequence.txt inputpath
645 or replace sequence.txt by the sequence number if the default
646 sequence file should be used.
647
648 - mars: The default size has been increased
649
650 - mars: There are two new heckboxes which allow to switch off
651 the calculated image parameters
652
653 - callisto: was broken for MCs... fixed.
654
655 - callisto: improved calculation of spline coefficients a lot. This
656 leads to a further improvement of the event rate calibrating MUX
657 data of about 15% (175evt/s instead of 150evt/s)
658
659 - callisto: finally the raw data we read is now real 16bit (with
660 10bit precision) for MUX data and not a stripped 8bit number
661 anymore. Due to scaling of the numbers (without precision loss
662 into an [0-256[ range, the final numbers for pedestal, pedestalrms
663 and extacted signal don't change. However, at all places where
664 raw data is directly accessed (eg. saturation and variation
665 limits in the signal- and pedestal-extraction) the numbers
666 refer still to the data's 16bit range.
667
668 - callisto: The maximum arrival time difference used in the bad
669 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
670 for both, old FADC and MUX-FADC, data.
671
672 - callisto: Be aware that callisto is now calibrating the arrival time
673 in nanoseconds rather than time slices. Also all following tasks
674 have been changed to assume ns units now. If you star data
675 calibrated with an older version it might be necessary to adapt
676 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
677 to obtain optimal results. The plot in the PulsePos tab
678 will now be in ns, too. This might also mean that the Muon
679 analysis in star might not work as perfect as expected as long
680 as old files read in.
681
682 - callisto: The calibration constants of earlier updates got lost
683 somehow. All constants have been updated.
684
685 - star: The PSF is now determined from the profile of the ArcWidth
686 instead of arcwidth/radius. The old way gave to much weight
687 to the bins with low statistics. The reference lines have been
688 updated.
689
690 - star: For speed reasons events suitable for the muon analysis
691 are now also preselected by fConcCOG<0.1 which seems to be a very
692 good preselector for muons.
693
694 - star: is now calculating a new timing parameter the Slope along
695 the major and minor axis of the shower. Therefore a numerical
696 solution of a line-fit is used. To use MHillasExt.fSlopeLong
697 and MHillasExt.fSlopeTrans don't forget to multiply it with
698 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
699
700 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
701 have been removed from MNewImagePar. They have never been good for
702 anything.
703
704 - star: Implemented a new recursive algorithm which is supposed to be
705 faster. Also implemented new cleaning oiptions, which are:
706 + CleanLevel0:
707 The cleaning level above single core pixels can be kept
708 + KeepIsolatedPixels:
709 Define whether single core pixels should be kept
710 + TimeLevel1:
711 The coincidence window in nanoseconds to single used neighbors
712 + TimeLevel2:
713 The coincidence window in nanoseconds to two used neighbors
714 + PostCleanType:
715 MOde in which a time dependent post cleaning should be applied
716 0: No post cleaning
717 1: Require for each used pixels at least one used neighbor
718 within a time-window of CleanLevel1
719 2: Require for each used pixels at least two used neighbor
720 within a time-window of CleanLevel2
721 3: Require first two and second one used neighbor
722 within a time-window of CleanLevel1 and fCleanLevel2
723 respectively
724 + RecoverIsolatedPixels:
725 - recoveres isolated core pixels if they have a used neighbor
726
727 - mars/star: The new default cleaning is:
728 + CleanLevel1: 6.0
729 + CleanLevel2: 3.0
730 + CleanTime1: 1.75
731 + CleanTime2: 1.75
732 + PostCleanType: 3
733
734 - star/ganymed: The old spark-cuts have been replaced by new ones.
735 These new spark cuts have been cross checked with the sequences
736 84720 (before splitter), 101041 (after splitter) and 223539 (new
737 FADCs). In all cases they seperate pretty well, but of course not
738 perfect. Monte Carlos have suggested to tighten the cuts a little
739 bit further at low sizes. This has been done.
740
741 - ganymed: IMPORTANT - The spark cuts have been changed to match
742 all available data more or less well. This might mean that for
743 YOUR data there are still sparks visible.
744 Whenever you do an analysis you have to make sure that NO sparks
745 survive your cuts!
746
747 - ganymed: The old hadronness and size cuts have gotten new indices
748 (10, 11). The old indices 8 and 9 now mean an additional condition
749 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
750 If you want to switch off this cut just move the line far away enough,
751 e.g. by setting c[9] to -500. Please update your ganymed.rc files
752 accordingly!
753 The unit of c[9] is deg. It is the dist at which your cut will
754 cross the slope==0. The unit of the slope is ns/deg. So if
755 you readin files calibrated with an older Mars-version you
756 have to adapt the default value for c[9] to the FADCs:
757 - Multiply by two for the MUX FADCs (run number > 200.000)
758 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
759 - Multiply by 42 for the meaning of life (run number = 200.000)
760
761 - ganymed: The old Cut0 is now called CutQ and is calculated before
762 the source position is caluclated. If you need a quality cut
763 including source dependant data (be very carefull with this!)
764 you have to use Cut0 instead.
765
766 - ganymed: now properly supports three off regions in wobble mode.
767 It will be the default from now on in ganymed_wobble.rc. To change
768 the number of off-regions use
769 NumOffSourcePositions: 1
770 in your ganymed.rc. Also by default no off-theta cut will be done
771 anymore so that you will get a background level higher than the
772 signal level in your ThetaSq plot for ThetaSq>0.2.
773 Due to this be carefull changing the scaling mode away from
774 "None". You will underestimate your signal if your scale interval
775 is not properly set.
776 (Rem: ThetaSqN is no longer needed)
777
778 - ganymed: is now storing the events of all (on- and off-)
779 source positions even in the case of more than one off-source
780 position. This should allow sponde to work properly and the
781 energy estimation is done correctly in all cases (without any
782 "nearest position" trick)
783
784 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
785 with a real pointing model for the starguider is done, calibrated
786 with more than thousand tpoints taken from this date on.
787
788 - ganymed: was broken for Wobble-MCs... fixed.
789
790 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
791 has changed. Note that your old ganymed.rc will be incompatible
792 with the new algorithms! Please check the ganymed.rc files and
793 the class description of MFMagicCuts for more information.
794 It is recommended at the moment to use identical Disp-Parametrizations
795 for on/off- and wobble-mode. If cuts are optimized only
796 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
797 should be optimized. All other values should be kept as they are.
798 If you want to do an anylsis without timing a parameters, you can
799 switch off the timing cuts by seeting parameter 7 to a very small
800 value (eg. -99). To remove the slope parameter from the disp
801 paremtrization set parameter 8 to 0.
802
803 - ganymed: The distribution of observation time versus zenith
804 angle is now shown for off- AND on-data.
805
806 - ganymed: The contents of the source position plot are no longer
807 averaged, thus a lot of (fake) events between the two wobble
808 positions have disappeared.
809
810 - ganymed: There is a new tab "CutT" it contains the VsSize plots
811 with the CutT, whihc is defined in ganymed.rc, applied. It
812 is resonable to use your theta-cut for it, to see if there is
813 something strange (sparks!) in your signal-region.
814
815 - ganymed: To choose a dataset from a collection in a dataset file
816 use the new command line option "--dataset=12345"
817
818 - optim, sponde: should now properly support three off-regions.
819 Just produce your ganymed summary files with three off-regions.
820 optim and sponde will automatically get all off events from
821 all off-regions from this file. Please do not forget to
822 set the scaling in optimwobble.C properly:
823 fit.SetScaleUser(1./3);
824 it is not yet read in automatically (will follow soon).
825 In the case of fixed Scale you can also use
826 cuts.SetThetaCut(MFMagicCuts::kOn);
827 no off-cut needed.
828 Be carefull in case of three off-regions when switching on
829 scale mode. Make sure that the scale interval is set correctly.
830
831 - sponde: sponde.rc and sponde_onoff.rc are now idetical
832
833 - sponde: the resouce files have been rewritten with a lot of
834 comments and a well working parametrization for an energy estimator
835
836 - sponde: In the estimated energy versus monte carlo energy plot the
837 contents where exchanged.... fixed.
838
839 - sponde: the so called "accurate"-mode has been removed. It didn't
840 give any improvement in accuracy, only decreased execution speed.
841
842 - sponde: the so called "simple"-mode has been removed. It didn't
843 give any improvement in simple.
844
845 - sponde: the so called "refill"-mode has been removed. It was anyhow
846 not implemented.
847
848 - sponde: now checks whether the theta distribution of your on-data
849 and the theta-distribution of your Monte Carlo sample (after
850 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
851 sample is incomplete) execution is stopped. Execution can be forced
852 using the new option --force-theta. Use this option with care!
853
854 - sponde: Proper collection areas can now be constructed also from
855 Monte Carlo samples generated with different maximum impact
856 parameters. Note that in previous version you neither got
857 a warning or failure, nor was there any obvious sign that the
858 collection area was overestimated due to usage of files with
859 different maximum impact parameters.
860
861 - sponde: If MC files with different lower energy limits are used
862 the primary MC spectrum is artificially completed down to the
863 lowest energy used at all. WARNING: that this gives correct
864 collection areas ONLY if none of the events in this region would
865 survive your cuts at all.
866
867 - sponde: the output file now contains more information about
868 the spectrum (eg. the full 2D collection area histogram).
869 Note, that this information can only be written to the file
870 if it is stored automatically via command line argument.
871 If you only store the status display from within the display
872 the information is lost.
873
874 - sponde: added a new tab "Disp". It shows the residual of the disp
875 (Disp-Dist) versus several parameters and it is meant to judge the
876 quality of the disp estimator. In the ideal case the residual is zero
877 and doesn't depend on any variable. The tab is displayed after
878 CutQ and Cut0.
879
880 - sponde: added a new tab "Energy". It shows the residual of the
881 energy (lg(estimated energy)-lg(monte carlo energy)) versus
882 several parameters and it is meant to judge the quality of the
883 energy estimator. In the ideal case the residual is zero
884 and doesn't depend on any variable. In reality even a good estimator
885 can show residuals versus Monte Carlo energy. The tab is displayed
886 after all cuts.
887
888 - sponde: added a new tab "EventDist" showing the unweighted real
889 absolute number of events of your sample after cuts. This tells
890 you how many events with this energy you had in your MC files.
891 The same information you get from the error bars of the weighted
892 histograms, but this is less intuitive.
893
894 - sponde: The spectrum plots now show the crab- and 1553-spectrum
895 for comparison. It is not meant to show these curves in
896 publications, they are only for production.
897
898 - sponde: The OriginalMC tree with the events produced by corsika
899 is now processed only once
900
901 - sponde: Finally fixed most annoying bug, which has effected the
902 last bin of the collection area. It was the problem that binnings
903 of root histograms are from 1 to n (included) but there was a C-like
904 loop in sponde from 0 to n (excluded). Now the loop also includes
905 correctly under- and overflow-bins. The worse thing with this is,
906 that for the events in the highest bin not only the bin-content
907 was wrong, but also the weights applied to these events, which could
908 in pricipal effect also other parts of the distribution (eg. due
909 to energy estimation). Fortunately it effected only a few events
910 in most cases.
911
912
913
914 *** Version 1.2 (2007/05/14)
915
916 - database: The database now has two new values Unsuitable50 and
917 Unsuitable01. They express the number of pixels which are
918 unsuitable for more than 50%, respectively more than 1%, of
919 all calibrated event. It is a more accurate number than the
920 previously used numbers, because they only take the first
921 calibration (ignoring the interleaved calibrations) into account.
922
923 - database: The database now has two other new values UnsuitableMax and
924 DeadMax. They express the maximum number of pixels which were
925 unsuitable, respectively dead, during the sequence. Because
926 of high pedestal rms (cars passing) a few events with very high
927 numbers of unsuitable pixels can happen. Not to suffer from this
928 effect we don't take the highest 0.1% of the numbers into account.
929
930 - general: fixed a bug which caused callisto and star to stop working
931 properly because the callisto output was currupted
932
933 - general: a script called scripts/makemovie has been added which
934 simplified the process of producing several movies from a single
935 sequence with different setup.
936
937 - callisto: Some more code cleanup. Started to remove old obsolete
938 code from cvs.
939
940 - callisto: The extraction of the pedestal with the extractor was
941 not random. It seems that extracting at one position is still biased
942 (for example in the first or last slices we could still suffer from
943 switching noise) Now it is completely random.
944
945 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
946 pedestal files) individual pixels could be skipped due to high
947 variations. This was already the case for the pedestal extraction
948 from the lo-gains since the beginning and properly handled
949 there, but was introduced in the extraction from the pedestal files
950 a while ago. To calculate the average value it was still divided
951 by the number of events procesed not by the number of summands
952 really summed. This let to a pedestal which was a tiny amount too
953 small (for a few piels in the order of 0.1%). This led to an slightly
954 positive offset of the randomly extracted pedestal for a few pixels.
955 I doubt that this has a big effect on the result, because the effect
956 on the individual numbers is quite small. Due to this it is suggested
957 that you rerun your calibration to make sure you are without any
958 avoidable bias.
959
960 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
961 the median rms of the absolute arrival time and expressed in significance
962 levels. This replaces the old meaning of an abolute upper limit. An
963 absolute upper limit doesn't make much sense, because in our data
964 all arrival times are shifted at the same time (in fact it might be
965 a shift of the artificial trigger w.r.t. to the light flash).
966
967 - callisto: Added a new tab "BadPixTm" which shows the time evolution
968 of the number of unsuitable pixels over the whole sequence. This
969 is usefull mainly to judge if an intermediate calibration had
970 problems.
971
972 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
973 of the number of dead pixels over the whole sequence. Dead pixels
974 in this context are unmapped pixels, i.e. pixels which could not
975 be interpolated, and thus are ignored in the further analysis.
976
977 - callisto: It is now possible to use the position of the maximum
978 of the spline as arrival time instead of the leading edge even
979 when using the integral for the signal. Therefor set the extraction
980 type to kIntegralRel ("IntegralRelative") and the relative height
981 ("HeightTm") to -1:
982 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
983 MJPedestalC1.ExtractSignal.HeightTm: -1
984
985
986
987
988 *** Version 1.1 (2007/04/27)
989
990 - general: The new class MGeomCamDwarf contains the camera geometry
991 for our prefered Dwarf camera and can be used to create general
992 geometries of roundish or hexagonal cameras.
993
994 - mars: The default cleaning is now abolute 8.5/4.0.
995
996 - mars: The resource file mars.rc now contains examples for MUX data
997
998 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
999 data containing only 10-bit information is still cooked down to
1000 8-bit, by cutting away the lowest 8-bit.
1001
1002 - merpp: When reading raw data the data is now stored in a single
1003 array. The lo-gain array is obsolete. The interface stays the same.
1004
1005 - callisto: To process the new MUX data use the resource file
1006 callisto_mux.rc
1007
1008 - callisto: The -root and -raw options to read merpped raw data have
1009 been removed
1010
1011 - callisto: If the -mc option is given the sequence-name can now be
1012 replaced by the MC sequence number
1013
1014 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1015 -mc option can now be omitted
1016
1017 - callisto: Started further simplification by removing obsolete
1018 dependancies on MCalibIntensity*Cams.
1019
1020 - callisto: removed unsused intensity calibration from MJCalibration
1021 for further simplification
1022
1023 - callisto: for simplification removed references to
1024 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1025 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1026 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1027 (this should at minimum change nothing at all, and at maximum
1028 improve thing if these containers where somewhere not handled
1029 properly)
1030
1031 - callisto: Added the option to write an event movie. Please use
1032 this option with care (huge files) but exessively to understand
1033 our events. For further documentation please refer to the
1034 IACT wiki
1035 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1036
1037 - callisto: Improved binning for the pulse position check histogram
1038
1039 - callisto: The code calculating the pulse position checknow takes
1040 the pedestal into account
1041
1042 - callisto: The arrival time is now stored with full precision this
1043 helps to get rid of artefacts in histograms. For the signal this
1044 is not necessray because it is displayed in log-scale anyhow
1045
1046 - callisto: Fixed a problem with internal exclusions. Pixels which
1047 have once been marked as unsuitable didn't get the necessary
1048 histograms filled anymore to be rechecked with each interleaved
1049 calibration.
1050
1051 - callisto: The relative arrival time resolution (the rms of the
1052 relative arrival time offset) is now checked against its
1053 median and the median deviation, instead of the average
1054 plus an absolute offset.
1055
1056 - callisto: The relative arrival time offset is now calculated
1057 w.r.t. its median not w.r.t. to an artificial reference pixel.
1058
1059 - callisto: The relative time calibration now marks pixels with
1060 outlaying offset as unsuitable
1061
1062 - callisto: The interleaved relative time calibration has been switched
1063 on. The advantage is that pixels which are marked as outliers
1064 now can recover. An improvement over time is not expected, because
1065 the relative time calibration seems stable.
1066
1067 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1068 option can now be omitted.
1069
1070 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1071 or the option "-mc" is specified as default the monte carlo datacenter
1072 paths (/magic/montecarlo/...) are used if not overwritten in the
1073 dataset file.
1074
1075 - ganymed: The output files now contain run- and event-number for all
1076 events, accessible as RunNumber.fVal and EvtNumber.fVal
1077
1078 - ganymed: Added a plot showing the source position in the camera also
1079 for wobble mode
1080
1081 - ganymed: In addition to the existing task which can be setup to
1082 be executed after Cut1 a final task called "EstimateEnergy"
1083 has been added, executed before writing the final output
1084 (ganymed00000000.root). The task setup in all three cases
1085 can be choosen individually. (For all three(!) cases you
1086 can for example choose MRanForestCalc. For examples see all
1087 sponde*.rc and all ganymed*rc)
1088
1089 - ganymed: If a container "MEstimatedEnergy" is found in the
1090 parameter list (eg. because it was setup by MEstimateEnergy)
1091 it will be written to the output file.
1092
1093
1094
1095 *** Version 1.0 (2007/02/16)
1096
1097 - database: Website to plot values from the database has been added.
1098
1099 - database: The rate of spark events as found by star is now kept
1100 and the rate after cleaning is now with spark events subtracted
1101
1102 - general: The changes to the interpretation of phrases lead to
1103 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1104
1105 - general: Added example files how you can create your own calendar
1106 (eg. as christmas present) with Mars. Just run
1107 root macros/tutorials/calendar.C
1108
1109 - general: Added a possibility to display grouped data in the plotdb.C
1110 macro (and similar macros). This allows to plot hourly, nightly,
1111 weekly, monthly and yearly averages.
1112 For more details see the plotall function of the macro
1113
1114 - general: fixed the error display of the camera display. It showed
1115 wrong results.
1116
1117 - general: fixed a memory leak when reading many MStatusDisplays
1118
1119 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1120 between a spherical and a parabolic mirror
1121
1122 - callisto: We have a new pulse position check which takes the properties
1123 of the extractor automatically into account. So no need to set
1124 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1125 left is done. If possible the lo-gain extraction start and hi-gain
1126 extraction end is changed accordingly. If no proper extraction range
1127 can be set (hi-gain too much to the left) an error is raised.
1128
1129 - callisto: New swapped pixels have been found and corrected
1130
1131 - callisto: Redone the signal extraction this includes:
1132 + Unified the algorithms to extract the pedestal for all pedestal
1133 extractions done
1134 + Unification of hi- and lo-gain into one array
1135 + Unification of hi- and lo-gain extraction for Spline and
1136 Digital Filter (means now exactly the same algorithm is used,
1137 not a copy-and-pasted one)
1138 + Store pedestal subtracted data in a common place
1139 + Improved extraction algorithms. If the algorithms search a
1140 maximum but don't find one they don't return the maximum anymore
1141 + Improved the extraction such that a information for signal
1142 and time which is consistent is returned
1143 + replaced the numerical spline with a (not slower) analytical
1144 solution
1145 + Lowered the saturation limit from 250 to 245 to make sure that
1146 we are far away in all pixels from problems with the clock-noise
1147 + The start of the lo-gain extraction is calculated from the hi-gain
1148 arrival time. In case of saturation an estimation is used.
1149 + the hi-gain window was extended to slice 16. This allows extraction
1150 of very late pulses in single pixels or of huge hadron showers.
1151 + Now uses the lo-gain extraction range for pedestal extraction,
1152 not the hi-gain range in the lo-gain
1153
1154 - callisto: New hi-/lo-gain calibration constants have been produced
1155 for all periods from the statistic of the whole period. They are
1156 now used automatically depending on the periods. The old constants
1157 where deviation in avarega about 2%-3%. The constants are very
1158 stable from period to period (<<1%) except for exchanged channels.
1159 In a few cases the constants used so far were off by 1%-2% (maybe
1160 temperature effects?)
1161
1162 - callisto: To gain obsolete space we do not write the
1163 MPedestalFundamental anymore. Also calibration and bad pixel
1164 treatment is not done for it anymore because it has never been used.
1165
1166 - callisto: Fixed a bug in the seuqence handling which caused the
1167 light condition to be ignored
1168
1169 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1170 basically the same as "Cleaned" but the distribution devided into
1171 the events fullfilling a spark cut or being rejected by it.
1172 This cut can be changed from star.rc (see example inside) by
1173 the "SparkCut" directive
1174
1175 - star: Star displays now the average individual pixel-rate (IPR) versus
1176 time and the average discriminator threshold (DT) of all pixels.
1177
1178 - optim: fixed a problem with the optim-macros which was due to a bug
1179 in the new phrase parsing
1180
1181 - ganymed: To get a nice FalseSource plot (instead of the all-information
1182 debug plot displayed as a standard plot) use the context menu
1183 somewhere between the two upper plots, click on "DrawNicePlot"
1184 and enjoy the result. (It is the same context menu which contains
1185 the other options)
1186 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1187
1188 - ganymed/optim/train: The cut program, trainings- and optimization
1189 macros could run with less files found than expected from the
1190 sequence-files. No the execution is stopped in this case.
1191
1192 - ganymed: now stores the dataset in the output file with all information
1193 contained (as sequence number, sequence path, data path) so that the
1194 used dataset file can be recreated complete from the output
1195
1196 - sponde: now also allows the uasge of random forest
1197
1198 - sponde: added a plot showing the cut efficiency
1199
1200 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1201 errors (eg. effecting the collection area) because the errors of the
1202 two histograms were swapped in the calculation, which makes a difference
1203 in the case the histograms contains weighted events. Aditionally the
1204 totalarea was incorrectly taken into account, which results in too small
1205 errors, which makes a difference at low statistics were the errors
1206 or the collection area dominate.
1207
1208
1209
1210 *** Version 0.10.3 (2006/10/23)
1211
1212 - database: Implemented ObservationMode flag in websites.
1213
1214 - database: For sequences there is now also the stoptime available on the
1215 websites.
1216
1217 - database: Removed ManuallyChanged flag from sequence-info websites,
1218 as it is not needed anymore with the new sequence building algorithm.
1219
1220 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1221 Class for calculation of confidence intervals (upper limits).
1222 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1223 Please read the class instruction of TRolke for more information.
1224
1225 - general: The programs now return 0xfe if the requested resource file
1226 doesn't exist.
1227
1228 - general: Errors comming from root itself are now not output to
1229 stderr anymore but to our default (colored) log-stream.
1230
1231 - general: Changed the interface to TFormula such that now everything
1232 is parsed by TFormula, which should allow to use phrases even
1233 without paranthesis correctly parsed.
1234
1235 - callisto: replaced the AdHoc number of effective integration slices
1236 in the digital filter by an average of the correct number, averaged
1237 over all possible set of weights. This also gives correct numbers
1238 for the lo-gains which were totally wrong before.
1239
1240 - callisto: drastically reduced memory consumption by not storing
1241 all intermediate calibration results in memory anymore (we might
1242 write them into a file in the future)
1243
1244 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1245 debug plot displayed as a standard plot) use the context menu
1246 somewhere between the two upper plots, click on "DrawNicePlot"
1247 and enjoy the result. (It is the same context menu which contains
1248 the "DrawAll" option)
1249 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1250
1251
1252
1253 *** Version 0.10.2 (2006/10/15)
1254
1255 - general: changed the building of the sequence files such, that
1256 the source-/project name in case of wobble-sources is not the
1257 source/project of the first data run anymore but the new generalized
1258 wobble source/project
1259
1260 - general: Added some functions to MAstro to calculate sun and
1261 moon properties
1262
1263 - general: Added two new macros (starvisday.C and starvisyear.C)
1264 which allow to plot the visibility of several stars in one day
1265 or of one star along one year
1266
1267
1268
1269 *** Version 0.10.1 (2006/10/11)
1270
1271 - general: HTML logging output was distorted... fixed.
1272
1273 - general: Changed the writing of the sequencefiles such that only
1274 as many pedestal files as giving at least 1000 pedestal events which
1275 are nearby the first calibration run are used as pedestal runs
1276
1277 - sponde: In the calculation of the collection area(s) and the
1278 distribution for MOnte Carlo and estimated energy the error
1279 calculation was wrong because root didn't take the errors
1280 properly into account... fixed.
1281
1282
1283
1284 *** Version 0.10 (2006/10/10)
1285
1286 - general: all executables now check consistency of the root version
1287 installed with the root version used for compilation. The return
1288 code in this case is 255.
1289
1290 - general: The algorithm to build seqeunces has been redesigned
1291 completly. It is now more flexible in terms of a resource file
1292 resources/sequences.rc which can be used to partly overwrite
1293 the default algorithm and defined the important part of the
1294 algorithm. It also takes correctly into account several ways
1295 of taking wobble-data. Currently the new algorithm doesn't take
1296 the number of pedestal events anymore into account (so a sequence
1297 could have much less than 1000 pedestal events and data runs are
1298 no-more used instead)
1299
1300 - general: a lot of small changes to make the code compatible with
1301 root 5.12/00 and gcc 4.1
1302
1303 - general: Fixed some warnings thrown if more warnings are switched
1304 on in the compiler
1305
1306 - general: Added a function to MMath which returns the Median of
1307 the distribution abs(y[i]-median) but at 68:32 division instead
1308 of 50:50, which is somehow the median counterpart of the rms.
1309
1310 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1311 even if they are compressed with gzip (recommended compression
1312 is with "-1")
1313
1314 - showplot:
1315 + batch mode creation of image files now works with root 5.12/00
1316 + added support for writing bmp (though it never produces
1317 bmp which can be read by programs like xv or gimp)
1318 + added support for xml
1319 + added new option to start the display with a different size, by
1320 --display-width=nnn or --display-height=nnn
1321 + added options to define the canvas size when the display is started
1322 --canvas-width=nnn or --canvas-height=nnn
1323 the option can also be used for batch-mode conversion
1324 + added an option which automatically fits the display size to the
1325 desktop-size: --auto-size
1326
1327 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1328
1329 - merpp: allow the reports to have 1000ms due to a bug in the camera
1330 program.
1331
1332 - callisto: New swapped pixels have been found and corrected. For
1333 details see MRawRunHeader::FixAssignment()
1334
1335 - callisto: Callisto now raises an error if one of the input files could
1336 not be opened.
1337
1338 - callisto: In some rare cases it could happen that in the signal
1339 extraction of the digital filter the extractor returned nonsense
1340 results due a wrong initializion of a variable (this happens in
1341 cases in which the extracted signal is exactly zero or the
1342 digital filter couldn't slide because of a too small extraction
1343 window, which could happen in the lo-gain extraction)
1344
1345 - callisto: The lo-gains have been marked as valid in some cases
1346 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1347 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1348 smaller than the number of slices (fLoGainWindowSize) needed
1349 by the lo-gain extractor
1350
1351 - callisto: Updated absolute calibration constants (muon calibration)
1352
1353 - callisto: fixed a bug which caused the hi-gain saturation not
1354 to be handled properly in the spline (the position of the
1355 saturation was calculated incorrectly)
1356
1357 - callisto: fixed a bug which gave weird results if hi- _and_
1358 lo-gain could not be extracted properly. In some cases hi-
1359 and lo-gain have not been extracted at all and the random result
1360 got calibrated. In other cases the hi-gain was saturating and the
1361 lo-gain has not been extracted. For this a completly arbitraty
1362 scale factor was applied to the result from extracting the
1363 charge of the saturating hi-gain.
1364
1365 - callisto: improves handling of extracted signal if lo- and/or
1366 hi-gain could not be extracted properly. If no appropriate
1367 calibration of either the signal or the arrival time is possible
1368 the pixel is now markes as unsuitable instead of estimated.
1369
1370 - callisto: Fixed a problem in the spline extraction which gave
1371 weird results if the signal was extracted from the first (and
1372 highest) slice (as a workaround extraction from the first
1373 slice has been forbidden)
1374
1375 - callisto: Fixed a bug regarding the use of the QE which doesn't
1376 effect the result because the default is used anyhow.
1377 (The bug was there since 14/07/2005)
1378
1379 - callisto: Changed the default for fgLoGainStartShift to -2.4
1380
1381 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1382 factors to be always 10 for all pixels as soon as the first
1383 calibration update has happend.
1384
1385 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1386 was off by more than one slice (which gives wrong values for
1387 pixels which have saturated the hi-gain) This was a problem
1388 mainly for timing studies, not so much for the automatic standard
1389 analysis. Also the values for the Spline have been changed slightly:
1390 + Digital Filter from 1.70 to 0.95
1391 + Spline from 1.39 to 1.30
1392 The numbers were sorted out by an extensive test in the
1393 test-database.
1394
1395 - callisto: Removed the tab showing the average calibrated arrival
1396 time. It never gave useful information.
1397
1398 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1399 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1400 and both were extracted because the hi-gain was above the
1401 LoGainSwitch.
1402
1403 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1404 lo-gain pulse position (after application of LoGainOffset, which
1405 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1406 have saturated and both were extracted because the hi-gain was above
1407 the LoGainSwitch.
1408
1409 - callisto: After extensive tests a new threshold level for determination
1410 of the pulse position has been found at 50phe. This is due to the
1411 fact that for lower pulses the arrival time changes its average
1412 behaviour dramatically. It tends to the average of the extraction
1413 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1414
1415 - callisto: Added two more plots to the calibration part. The average
1416 extracted signal and the average extracted arrival time as
1417 extracted by the signal extractor (This can help debugging problems
1418 because it doesn't involve a fit)
1419
1420 - star: changed the fit for the effective on time such that initial
1421 values are calculated automatically now instead of using build
1422 in values. This makes the fit more indepedant of the underlaying
1423 rates. With a test of ~350 sequences in the test database it could
1424 be shown that the new fit gives the same result +/-1sek.
1425 The highest deviation was +5s the lowest -10s. You can now control
1426 the bahaviour with two resource values:
1427 MHEffectiveOnTime.FistBin: 3
1428 MHEffectiveOnTime.NumEvents: 12000
1429 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1430 from the resulting gamma candidates
1431
1432 - star: The Center histogram in MHHillas is now by default displayed
1433 with the colz draw-option
1434
1435 - ganymed: now produces valid error codes if failed
1436
1437 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1438 with the option "hadronness" instead of "area" or "both" if
1439 you want to use both cuts. The hadronness cut includes a fixed
1440 cut in hadronness (index 8) and a fixed cut in size (index 9).
1441
1442 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1443 the M3Long of the anti source to be not properly evaluated
1444 (actually is was evaluated as a unique random number) in case
1445 of optimization with anti-theta cut switched on. This might have
1446 lead to improper, but not necessarily wrong, optimization results.
1447
1448 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1449 how to use random forest
1450
1451 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1452 ganymed_onoff.rc. Seems to be unintentional that they were different.
1453
1454 - sponde: Since the introduction of the possibility to define a
1455 normalization energy instead of using the integral the default
1456 was not using the integral anymore but a normalization energy of
1457 1GeV. It is now the integral again.
1458
1459 - sponde: Fixed a problem in the weighting which did not allow
1460 a MC slope of -1.
1461
1462
1463
1464 *** Version 0.9.6 (2006/05/24)
1465
1466 - general: changed the binning of the azimuthal profile of the camera
1467 such that it is aligned with the 60deg boundaries.
1468
1469 - merpp: better handling of problems with the TH, TD part of the
1470 CC-REPORT for files older than 200507190 and 200412210
1471 respectively
1472
1473 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1474
1475 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1476
1477 - callisto: if an arrival time is extracted outside the fadc range is
1478 was set to the boundary before. Now a random number is assigned
1479 instead to avoid unfortunate coincidences of arrival times just
1480 by this arbitrary value.
1481
1482 - callisto: added a new option to callisto.rc which allows
1483 to set the maximum arrival time difference allowed for the
1484 badpixel algorithm to determin whether a pixels belongs to a shower:
1485 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1486
1487 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1488 to 0.9 as suggested by Stefan due to a recent study on the fraction
1489 of pixels surviving the image cleaning
1490
1491 - callisto: switched off error in case of "pulse is too much to the left"
1492
1493 - callisto: The extraction window is not adapted anymore. This means that
1494 the pulse is extracted from the full range. The draw-back is that the
1495 background (pedestal) will become slightly higher. Switching on/off
1496 the PulsePosCheck in the callisto.rc only effects filling the
1497 histograms.
1498 WARNING: If the pulse is too much to the left data is calibrated!
1499 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1500 in the database to make sure that your data is valid!
1501
1502 - star: Show also the number of stars correlated correctly by the
1503 starguider
1504
1505 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1506 than one off-source region in wobble-mode. To use it add the following to
1507 your ganymed_wobble.rc:
1508 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1509 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1510 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1511 + Cut1.ThetaCut: None
1512 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1513
1514 - ganymed: in the case the latest report is older than a default (currently
1515 one minute) and the current report will be skip the starguider
1516 correction and calibration will be reset. The maximum age can be
1517 setup from ganymed.rc by (minutes):
1518 MPointingDevCalc.MaxAge: 1.5
1519
1520 - ganymed: A first implementation showing all size-bins for the theta-sq
1521 resp. alpha-plots in a single tab automatically
1522
1523
1524
1525 *** Version 0.9.5.1 (2006/05/05)
1526
1527 - general: Added a new option "zdiff" to the Makefile which runs
1528 "cvs diff" as "make diff" would do, but with compression
1529
1530 - general: accelerated MTFillMatrix (used for eample in all training
1531 and optimization macros) by skipping some obsolete calles in the
1532 eventloop the first and second loop could be accelerated by ~20%
1533
1534 - general: Added a missing feature in the MFilterList class which
1535 prevented MFEnergySlope from working correctly in trainenergy.C
1536
1537 - general: Accelerated the random forest training and usage a bit
1538
1539 - merpp: Adapted to new raw data file format version 6
1540
1541 - merpp: fixed a problem with reading the starguider reports
1542 after 6.3.2006
1543
1544 - callisto: At some times six pixels had to be exchanged manually in the
1545 data. If the pixels to be swaped are both not found, an error was raised
1546 and calibration was stopped. Now it is assumed they are intentially not
1547 mapped and the Error has been changed to a Warning.
1548
1549 - star: Added new image cleaning based on the arrival time of the shower.
1550 The new cleaning can be accessed using the parameter "Time" instead of
1551 the the old one (like "Absolute) in the star.rc-file.
1552 Recommended parameters:
1553 + MImgCleanStd.CleanLevel1: 8.2
1554 + MImgCleanStd.CleanLevel2: 5
1555 + MImgCleanStd.CleanRings: 2
1556 + MImgCleanStd.KeepSinglePixels: No
1557
1558 - star: Simplified the calculation of the effective on time. By letting
1559 the fit start in the third bin the result should become more stable.
1560 The fit quality is now ignored for the theta-plot which is not used
1561 in the analysis later. Still better pre-cut which, for example,
1562 remove events triggered by car-light (rate changing on a short
1563 time-scale) are missing.
1564
1565 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1566 for optimization (kWeakSource) which is suggested by the Berlin
1567 people for weak sources.
1568
1569 - macros: plotdb.C:
1570 + if no dataset and no time-interval is given only sequences with
1571 an effective on-time above five minutes are plotted anymore
1572 + added a new tab "RelTime" displaying the relative on-time
1573 (effective on-time divided by the observation time)
1574
1575 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1576 the optimization became a lot faster
1577
1578 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1579 To display them just delete the pads displayed on top.
1580
1581 - ganymed: fixed a bug which could cause strange behaviour in wobble
1582 mode if no starguider information was available due to an incorrect
1583 initialization of the starguider calibration
1584
1585 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1586 be changed from within the plot. It can also be setup from the
1587 resource file using:
1588 + MHDisp.fScaleMin: 0.325
1589 + MHDisp.fScaleMax: 0.475
1590
1591 - ganymed, showplot: Fixed a problem with the fit to the off-data
1592 (HistOff) which could cause a time lag or an inifinite loop.
1593 The bug did not effect the results at all.
1594
1595 - sponde: Added a new tab showing the effective collection area after
1596 trigger (including the software trigger)
1597
1598 - sponde: MMcSpectrumWeight has a new option which allows to define
1599 the scaling factor not by the integral of the events but at
1600 a defined energy:
1601 e.g. MMcSpectrumWeight.NormEnergy: 200
1602
1603 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1604 eventloops the loop could be accelerated by ~20%
1605
1606
1607
1608 *** Version 0.9.5 (2006/03/13)
1609
1610 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1611 and added the standard Disp-parametrization
1612
1613 - macros: added a new macro datacenter/macros/plotstat.C allowing
1614 to plot statistics about the data processing
1615
1616 - macros: added a new macro to plot the muon correction coefficients
1617 versus period (macros/plot/mucal.C)
1618
1619 - showplot: path inflation for ganymed files was broken
1620
1621 - callisto: Fixed an important bug. When the number of saturating pixels
1622 were calculated the bad pixel information already available from the
1623 calibration was ignored. This yields wrong values in case pixels
1624 are broken and saturate all the time or randomly.
1625
1626 - callisto: Updated Muon calibration constants. Spline data now also uses
1627 different values for different periods
1628
1629 - star: The time-evolution shown in the effective on-time plot now displays
1630 the axis range (if there are no holes it should be similar to the
1631 effective on-time)
1632
1633 - star: Added two new image parameters:
1634 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1635 the three pixels next to the center of gravity and the size
1636 + MNewImagePar.fConcCore: The ratio of the signals of all
1637 pixels inside or touching the ellipse and the size
1638
1639 - ganymed: now stops in requested source isn't found in catalog file
1640
1641 - ganymed: Many improvements to the phi-plot in wobble mode:
1642 + with a template the ideal background is displayed
1643 + a possible camera inhomogeneity is taken into account
1644 + the anti theta cut is better supported
1645 + the phi cut is automatically calculated from the theta cut
1646 See the examples in ganymed_wobble.rc for more details.
1647
1648 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1649 times the bin-width instead of the absolute energy
1650
1651 - ganymed: New cuts for on/off and wobble mode
1652
1653 - ganymed: The smearing of the False Source plot has been increased
1654 to 0.06
1655
1656 - ganymed: The starguider calibration can now be changed from the
1657 resource file.
1658 See the examples in ganymed*.rc for more details.
1659
1660 - ganymed: added a new option for on-/off-observations
1661 MJCut.RandomSourcePosition
1662 If switched on the distribution of observation time of the source
1663 position in the camera is calculated from the on-data and randomly
1664 applied with this distrbution to the off-data.
1665
1666 - ganymed: by skipping some obsolete calles in the eventloop the
1667 first and second loop could be accelerated by ~20%
1668
1669 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1670 position in the off-data randomly according to its distribution in the
1671 on-data.
1672
1673
1674
1675 *** Version 0.9.4.3 (2006/02/13)
1676
1677 - general: Fixed a bug in most of the programs which prevented the
1678 compile date in the startup message to be displayed
1679
1680 - general: Simplified program calls. The following abbreviations
1681 are now possible:
1682 showlog callisto 55599
1683 showplot signal 55599
1684 star 55599
1685 callisto 55999
1686 ganymed 2
1687 In this cases the corrsponding root-, log-, sequence- or dataset-
1688 filename is automatically compiled using the default datacenter
1689 paths ("/magic/*")
1690
1691 - general: Fixed a long outstanding bug which made axis tick marks
1692 disappear if MDataFormula was used (eg. abs(x))
1693
1694 - general: Updated MMath with new functions to calculate the results of
1695 a exponential, logarithmic and powerlaw fits analytically.
1696
1697 - general: Updated some macros with comments:
1698 + macros/optim/optimdisp.C
1699 + macros/optim/optimenergy.C
1700 + macros/optim/optimwobble.C:
1701
1702 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1703 files) now allows adding a pre-cut like in the optimization. E.g. this
1704 is useful to perform g/h-separation cuts before training the random
1705 forest.
1706
1707 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1708 correctly assigned in the raw data assignement table. A fix to correct
1709 the assignment tabel have been implemented.
1710
1711 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1712 by 90, 180 and 270 deg.
1713
1714 - general: the macro plotdb.C now allows to highlight sequences belonging
1715 to a datset. For more details see the descritions in the macro.
1716
1717 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1718 of the display, it gave wrong results espacially for big sizes.
1719 Now the embedded canvas should always have a ratio width/height=3/2.
1720 The "Size" options have been updated with values fitting the 3/2
1721 size ratio.
1722
1723 - RanForest:
1724 + Updated the random forest classes to support also the
1725 regression method implemented by Thomas H.
1726 + added new tutorial macro how to train the random forest
1727 for energy estimation (macros/optim/rfenergyest.C)
1728 + new classes to train the random forest (still in development)
1729 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1730 + new tutorial macros for random forest training in macros/train
1731 trainenergy.C, traindisp.C, trainseparation.C
1732
1733 - mars: now allows to setup a cut in the resource file mars.rc to choose
1734 the events to be displayed, eg:
1735 Cut.Condition: {0} && {1}
1736 Cut.0: MHillas.fSize>100
1737 Cut.1: MHillas.fSize<900
1738
1739 - merpp: Made aware of the new .rep format 200510250. This includes
1740 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1741 the discriminator thresholds (MCameraTD) and the disciminator
1742 delays (MCameraTD). All of them come with the CC report and are therefor
1743 written to the CC tree.
1744
1745 - callisto: fixed a bug in the calculation of the arrival times in
1746 the Digital Filter. They were all shifted by the same amount
1747 fHiGainFirst. This caused an offset in the order of the position of
1748 the left border of the extraction window in the times calculated
1749 from high-gain and from low-gain. The bug effected only the absolute
1750 arrival times. The bug was there since 30.1.2005.
1751
1752 - callisto: Changed the ExtractionWindow for the pulse position check
1753 such that the camera inhomogeneity becomes as less as possible and
1754 comparable to the pulso position check switched off. More details
1755 on the study will be given at our result web-page.
1756
1757 - ganymed: ganymed.rc, ganymed_onoff.rc:
1758 changed to new cuts trained with 1ES1218 and Crab-data
1759 for maximum sigma*log10(excess)
1760
1761 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1762 a new option was implemented to estimate Disp (CalcDisp)
1763
1764 - ganymed: Implemented two new options which allow
1765 to overwrite the default path to search for the sequence files
1766 --ins=/magic/sequences
1767 and where to search for the image data
1768 --ind=/magic/data/star
1769
1770 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1771 dx/dy from the resource file by
1772 MSrcPosCorrect.Dx
1773 MSrcPosCorrect.Dy
1774
1775 - ganymed: fixed reading the source catalog. Only as many chars
1776 as the requested source name had were compared (If a source
1777 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1778 were requested it could happen that the coordinates of
1779 "1ES1218" were read) The source coordinates are now printed
1780 in addition to its name to the logging output.
1781
1782 - ganymed: changed the background fit in the case of a ThetaSq function
1783 from a polynomial to a exponential, this should give a big improvement
1784 for on-only analysis'
1785
1786 - ganymed/sponde: Calculation of the error of single size-/energy-
1787 bins now uses Li/Ma (5) instead of LiMa (17)
1788
1789 - sponde: Added a plot E^2*dN/dE
1790
1791 - sponde: The energy estimator plot should now show values like
1792 they are commonly used.
1793
1794 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1795 (a powerlaw with cutoff didn't work before)
1796
1797
1798
1799 *** Version 0.9.4.2 (2005/10/01)
1800
1801 - general: added new tutorial macro macros/tutorials/threshold.C:
1802 how to calculate the threshold
1803
1804 - general: added a new game. Start it from the interpreter with
1805 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1806 and MagicReversi)
1807
1808 - general: neighbor pixels in MGeoms are now sorted clockwise
1809
1810 - merpp: made aware of new format 20050829-0
1811
1812 - callisto: New scale factors from muon analysis, stored in new
1813 resource file resources/calibration.rc
1814
1815 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1816 the eventloop if something went wrong. This is necessary for the
1817 automatic processing
1818
1819 - callisto: Implemented a new treatment for the time information
1820 developed by S.Ruegamer, this should give much better response than
1821 the old very primitive algorithm. This is especially important
1822 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1823 treatment was buggy! As neighbor pixels to interpolate the
1824 arrival times always the pixels 0 to 5 were taken)
1825
1826 - callisto: In addition to the new treatment of arrival times the
1827 decision of the treatment whether a pixel contains shower
1828 information or not is used to improve the signal interpolation
1829 further. Previously interpolated pixels showed a non-zero signal
1830 do the peak searching signal extractors. Having a signal pixel
1831 beside raised the signal above the cleaning level. Thus the
1832 pixel survived cleaning to often but with a too low mean signal.
1833 By replacing empty pixels with a gaus (mean and rms from the
1834 corresponding Area entries in MPedPhotCam) this effect can
1835 be supressed.
1836
1837 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1838 got lost when the events were stored by the calibration... fixed.
1839 (This was no problem for normal image cleaning because the pixel
1840 content was artificially set to 0 not surviving standard cleaning
1841 algorithm)
1842
1843 - callisto: Fixed a bug which caused the random and peak-search pedestal
1844 extracted with an extractor to be exchanged for the first (roughly)
1845 500 events (*Extractor and *ExtractorRndm).
1846 (They were simply exchanged in callisto.cc) This bug might have been
1847 introduced in Mars 0.9.4 when the order of calculation of the two
1848 types of pedestal in callisto got exchanged. The bug only effects
1849 the first seconds of data of each sequence.
1850
1851 - star: Taking the arrival time of Muons into account the calculation
1852 of the parameters could be made independant of the noise
1853 (pedestal rms). The dependance was due to the bias of the peak search
1854 extractor. Now only a ZA dependamcy is left which is not yet fully
1855 understood.
1856
1857 - ganymed: The sequences were still not sorted correctly in any case,
1858 because they were sorted by the full qualified path name. Now they
1859 are sorted by their sequence number.
1860
1861 - ganymed: new values for the spark-event-cut
1862
1863 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1864
1865
1866
1867 *** Version 0.9.4.1 (2005/08/18)
1868
1869 - callisto: fixed some problems with the calibration in case of
1870 inteleaved events. Therefor the final and some intermediate
1871 fits are skipped which would take place on partly filled #
1872 histograms and gave wrong results or failed completely.
1873
1874 - callisto: If the intermediate finalization of the histograms
1875 calculating the mean charge of the calibration signal fails
1876 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1877
1878 - ganymed: Fixed some bugs which caused problems in On-only mode.
1879 Still the false source plot doesn't give reasonable results.
1880
1881
1882
1883 *** Version 0.9.4 (2005/08/05)
1884
1885 - general: Fixed the ZA binning. It did not correctly fit the
1886 MC binning
1887
1888 - general: Added a class to correct for the missfocussing in
1889 April (MSrcPosCorrect)
1890
1891 - general: Random Forest energy estimator should now work properly
1892
1893 - general: MHCamera now displays the profiles in deg instead of mm
1894
1895 - general: MH::SetPalette offers a lot of new palettes
1896
1897 - general: MHillas - the case of CorrXY==0 is now handled properly
1898
1899 - general: implemented the possibility to change the line and
1900 marker style of a sky-grid drawn by MAstroCatalog
1901
1902 - general: Runs in sequences and datasets are now automatically
1903 ordered (it is assumed that the order of their filenames correctly
1904 represents the order of observations) to ensure correct reading
1905 of the subsystem data
1906
1907 - general: Runs cannot be added to a sequence twice anymore. Also
1908 Sequences cannot be added twice anymore to a dataset.
1909
1910 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1911 It gave wrong results by 1./2pi
1912
1913 - showplot: got a new option to start a root interpreter, too
1914
1915 - mars: now displays a rough estimate of Disp and the third moment
1916
1917 - mars: now displays the event time MTime if available
1918
1919 - mars: show muon parameters graphically
1920
1921 - mars: now the file to open can be given as commandline
1922 argument
1923
1924 - merpp: Added support for new arehucas version >= 200507190
1925 implementing values for three temperature sensors in the
1926 counting house (MCameraAUX) and the name of the HV settings file
1927 (MCameraHV).
1928
1929 - merrp: Also fixed some problems with wrong versions numbers stated
1930 by arehucas and implemented some fixed for old versions (<200407070)
1931
1932 - callisto: MCalibrationHiLoCam can now be printed from its context
1933 menu, eg in the TBrowser
1934
1935 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1936 - 1.39 (MExtractTimeAndChargeSpline)
1937 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1938 This is important mainly for timing studies.
1939
1940 - callisto: Changed limits in MHCalibrationChargeCalc from
1941 - -100.125 to -98 (fgChargeHiGainFirst)
1942 - 1899.875 to 1902. (fgChargeHiGainLast)
1943 - -100.25 to -99 (fgChargeLoGainFirst)
1944 - 899.75 to 901. (fgChargeLoGainLast)
1945 Introduced new limits:
1946 - fgNumLoGainBlackoutLimit: 0.05
1947 - fgLoGainBlackoutLimit: 3.5
1948 - fgLoGainPickupLimit: 3.5
1949
1950 - callisto: The handling of automatic weights for the digital filter
1951 has been improved. There are now new calibration weights special
1952 for Monte Carlo calibrations.
1953
1954 - callisto: Updated Muon scale with latest results (1% difference
1955 for most data, 5% for Mar/Apr'05)
1956
1957 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1958 was saturated and the blackout-events in the low-gain exceed the
1959 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1960 This excludes those pixels which have a saturating high-gain
1961 channel, but the low-gain switch does not switch often enough
1962 to make the distribution reliable.
1963
1964 - callisto: fix a bug counting the number of saturated events. Up to now,
1965 the number of saturated slices was counted (which is one for a not too
1966 high number), but for some (pathological) pixels, many more slices
1967 saturated and produced wrong limits.
1968
1969 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1970 + MCalibrationRelTimeCam.CheckFitResults: Yes
1971 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1972 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1973 + MCalibrationRelTimeCam.CheckOscillations: Yes
1974
1975 - callisto: introduce max. number of events for intercalibration,
1976 the rest gets skipped. Default: 4096
1977 The calibration causes too many un-reliable pixels if more
1978 than about 5000 events are treated (@500 Hz) because of the
1979 mode hopping of the VCSels. However, in the past, some
1980 calibration runs have been taken (erroneously) with more
1981 than 5000 events, especially the intensity scans where
1982 a good precision is needed.
1983
1984 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1985 photo-electrons for the spline extractor by 1-2% (correctly).
1986
1987 - callisto: The intercalibration is now done using a full f-factor
1988 method instead of a simple update. This makes things slower but
1989 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1990 changes.
1991
1992 - callisto: MPedestalY3 now uses the same extraction range as the data
1993 as calculated by MPedestalY2
1994
1995 - callisto: A check of the fraction of allowed unsuitable (10%) and
1996 unreliable (30%) pixels has been addded when the conversion is
1997 calculated from interleaved events
1998
1999 - star: fixed a bug which caused MEffectiveOnTime containers not to
2000 be written. In the worst case they were skipped almost all, in the
2001 best case they were all ok. It depends on how often the new value
2002 was assigned just with an event which was skipped later by another
2003 task
2004
2005 - star: new histograms MHPointing and MHRate
2006
2007 - star: New tab (Currents) displaying the time evolution of the mean
2008 DC currents
2009
2010 - star: New tab (MeanRms) displaying the time volution of the mean
2011 Pedestal Rms
2012
2013 - star: Output now contains MReportStarguider
2014
2015 - star: Improved muon analysis. Due to the absense of a constant
2016 for the gaus fit for arc width and the fact that the arcwidth
2017 plot was a histogram instead of a profile the resulting psf
2018 became pedestal rms dependant
2019
2020 - ganymed: added new plot (MHPhi) for wobble mode as described in
2021 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2022
2023 - ganymed: corrects now (correctly?) for the misspointing in
2024 May/April 05
2025
2026 - ganymed: Two new default templates for ganymed.rc are avilable:
2027 ganymed_onoff.rc and ganymed_wobble.rc
2028
2029 - ganymed: The first version of MFMagicCuts has been released
2030
2031 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2032
2033 - ganymed, sponde: There are two new options to determin the number
2034 of bins for the signal region (NumBinsSignal) and the number of
2035 total bins (NumBinsTotal) in the MHThetaSq histogram
2036
2037 - ganymed: optimized palettes for MHDisp
2038
2039 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2040 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2041 sqrt(2) to large
2042
2043 - ganymed: The false source plot (MHDisp) is now based on Disp
2044 and a background model determined in the first loop is
2045 subtracted
2046
2047 - ganymed: MFMagicCuts are now available in the cvs. The correct
2048 solution for the disp ambiguity problem is now calculated using
2049 the third moment. The third moment cut therefor is skipped.
2050
2051 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2052 already determined by the third moment along the major axis and
2053 so its actual sign is aligned along the major axis of the shower.
2054
2055 - ganymed: If starguider data is available it is taken into account
2056 when calculating the source position. This is especially important
2057 for wobble data at high zenith angles and culmination data.
2058
2059 - ganymed: If available the starguider data is taken into account as
2060 good as it is possible without a starguider calibration. To switch
2061 it off add
2062 MPointingDevCalc.MaxAbsDev: -1
2063 to your ganymed.rc
2064
2065 - sponde: the zenith angle distribution is now weighted instead of
2066 choosen by default. This gurantees higher statistics in the highest
2067 and lowest energy bins. To switch this behaviour off use...
2068
2069 - sponde: now automatically displays the energy threshold
2070
2071
2072
2073 *** Version 0.9.3 (2005/06/03)
2074
2075 - general: MMcEvt now derived from MMcEvtBasic which should
2076 have no influence on compatibility with older camera files
2077
2078 - general: Implemented a new option to MReadReports which allows
2079 to force reading of the first event of some trees (eg. Drive-tree)
2080 before any other tree.
2081
2082 - general: Made a fix to MPointingPosCalc which assumes that the
2083 run-type is real-data if Process is called before ReInit, such
2084 that also the very first Drive-events in a run are treated
2085 correctly.
2086
2087 - shoplot now displays the filename in the title bar of the window
2088
2089 - merpp: new options: --auto-time-start --auto-time-stop which
2090 allow to cut updating with slow-control at the start- or
2091 (previousle --auto-time only allowed: and) stop-time of
2092 the run stored in the runheader.
2093
2094 - callisto: changed default of fgFallTimeHiGain in
2095 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2096 already set as default in callisto_Dec04Jan05.rc
2097
2098 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2099 now changes the filename for new weights automatically for
2100 cosmics, MC and for different calibration colors.
2101
2102 - callisto: a problem with the order of some code cause the
2103 name of the weights file in MPedestalY2 to be ignored.
2104 Wrongly the calibration_UV weights were used instead
2105 of the cosmics weights set in callisto.rc.
2106
2107 - callisto: should allow ct1 pulser data when the color is
2108 explicitly set also for pretty new runs
2109
2110 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2111 to introduce an additional scale factor (should be around 1)
2112 to adapt for slight deviations in different extractors from
2113 the MC calibration. For MC calibrations the scale factor
2114 is fixed to 1
2115
2116 - callisto: MFCosmics should handle very high signals a bit
2117 more accurate now
2118
2119 - callisto: when calculating the mean pedestal rms for different
2120 pixel sizes or sectors also kUnsuitableEvt is now taken into
2121 account - not only kUnsuitableRun
2122
2123 - callisto: '-raw' option is now the default
2124
2125 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2126 This has the advantage that mean values in the calibration (eg
2127 arrival times) are calculated more accuratly.
2128
2129 - callisto: In the resource file callisto_Dec04Jan05.rc
2130 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2131
2132 - callisto: new Hi-/Lo-Gain intercalibration constants
2133 hilocalib_sp1.root and hilocalib_sp1_mc.root
2134
2135 - callisto: changed default for MJPedestalY2.MaxEvents
2136 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2137
2138 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2139 has changed from 9.0 to 6.0. This is necessary to exclude two very
2140 ringing pixels in September which - when kept - destroy the image
2141 cleaning around them (Markus G.)
2142
2143 - callisto: (!) The Muon analysis of all data taken so far has
2144 suggested that different extractors give slightly different
2145 absolute results after calibration, due to there different
2146 handling of the calibration- and cosmics pulse shape. Although
2147 the over all calibration seems to be a bit to pesimistic (or
2148 the MC seems to be a little bit - 3-5% - too much attenuated).
2149 There for correction factors have been introduced which correct
2150 the calibration constants by
2151 0.956937799 for Digital Filter (callisto.rc)
2152 and
2153 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2154 calibration. The main advantage is, that both data types can
2155 be easily analysed together and compared to the same MC sample.
2156 The factors are choosen such, that the reference is now a
2157 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2158
2159 - star: fixed a bug which caused the first bin of the histograms
2160 vs time to disapear in PostProcess. This gave wrong results
2161 on the screen. The output and all following programs not
2162 directly accessing the histograms haven't been affected
2163
2164 - star, ganymed: Made sure that always the first Drive-tree event
2165 is read and Processed before the first data event was read.
2166
2167 - ganymed: implemented the possibility to replace the standard
2168 false source plot with a different one. For example: If
2169 you want to use a Disp based FS plot use the resource:
2170 NameHistFS: MHDisp
2171 For details about the requirements of these plots look
2172 at the corresponding classes
2173
2174 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2175 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2176 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2177 case MAlphaFitter is setup correctly. For On-Only optimization
2178 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2179 RunOn() instead of Run(). For energy estimation MJOptimize
2180 has been replaced by MJOptimizeEnergy
2181
2182 - sponde: The input MC spectrum can now be weighted to fake a
2183 different spectrum. This is done via MMcSpectrumWeight. For
2184 more details see the class description and sponde.rc
2185
2186 - sponde: The paremeter comparsion plots are not scaled by
2187 their entries anymore. Instead the MC plot is scaled by using
2188 the result spectrum of the analysis. If the input MC spectrum
2189 and the result spectrum has different slopes the absolut
2190 normalization is normally wrong.
2191
2192
2193
2194 *** Version 0.9.2 (2005/05/20)
2195
2196 - general: Changed the default paths for calibrated data and image
2197 files. (The implemented access to these files doesn't yet exist)
2198
2199 - general: support for MRunIter has been removed from the job classes
2200 (use the setter functions of MSeqeunce instead)
2201
2202 - general: ProcessFile has been renamed to Process in all job classes,
2203 because ProcessFile is missleading
2204
2205 - general: The storage of the palette in MHCamera is now possible
2206
2207 - general: new bits describing unsuitable and unreliable pixels have
2208 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2209 kDeadPedestalRms, kFluctuatingArrivalTimes
2210
2211 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2212 versions newer than V200404070
2213
2214 - general: support for cc file versions newer than V200504130. Added
2215 support for active loads (MCameraActiveLoad) and central pixel
2216 (MCameraCentralPixel)
2217
2218 - general: added new histograms for image parameters versus size
2219 (MHVsSize)
2220
2221 - general: The eventloop now automatically calls PrintStatistics
2222
2223 - Status Display: Improved support for printing:
2224 + A default can now be set in .rootrc (for more details see
2225 MStatusDisplay::PrintPS)
2226 + A print dialog is opened so that printer and command line
2227 can be canged
2228
2229 - showlog: improved such that it handles different verbosity levels
2230 more accurate now. This mean you can suppress output when
2231 using showlog.
2232
2233 - showplot: improved
2234 + The new graphics formats have been implemented
2235 (pdf, svg, png, jpg and xpm)
2236 + Implemented an interface for printing. Because you can change
2237 the printing command from the command line you can use all
2238 the nice postscript tool. To print a booklet for example call:
2239 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2240 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2241 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2242
2243 - callisto: fixed a bug in the recognition of the calibration bit
2244 pattern. Concerns only intensity calibration. (The strength of the
2245 intensity has been updated in some cases)
2246
2247 - callisto: add a filter against PIN Diode events when running over
2248 calibration runs since some of the recent calibration runs have
2249 been taken with Pin Diode.
2250
2251 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2252 39943, 44833 in the calibration (MCalibColorSet)
2253
2254 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2255 been set to 1e-18 in callisto_Dec04_Jan05.rc
2256
2257 - callisto: in callisto_Dec04Jan05.rc: set value for
2258 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2259 statistics for the calculation of the mean pulse time
2260 of the cosmisc
2261
2262 - callisto: the charge limit in the calibration has been raised
2263 from 2.5 to 4.5
2264
2265 - callisto: new setup read from callisto.rc
2266 + MCalibCalcFromPast.fNumEventsDump
2267 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2268 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2269
2270 - callisto: MExtractTimeAndChargeSpline extractor:
2271 + The integration ranges were shifted by 0.2 FADC slices to the right.
2272 + unreliable handling of floating point values caused different
2273 results on different platform or with different compiler options:
2274 The new algorithm is numerically exact and more accurate because
2275 it doesn't calculate the integration position by multiple times
2276 adding the step-size (which results in numerical uncertanties
2277 exspecially if multiplied with large numbers)
2278 + A lot of fixes have been introduced which effects integrating the
2279 spline at the edges of the valid range. In this case any memory
2280 was randomly accessed. This behaviour can be tested replacing
2281 all MArrayF by TArrayF which perform a range check (but of course
2282 they are a lot slower)
2283 ! No result obtained with the Spline before can be trusted! Due to
2284 random memory access it might by completely random!
2285
2286 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2287 + extraction range in the high gain to 4.
2288 + weights file to cosmics_weights46.dat
2289
2290 - callisto:
2291 + introduce the check for fluctuating arrival times.
2292 + set charge limit to from 2.5 to 4.5
2293 + introduce asymmetric exclusion due to "deviating number of phes":
2294 Default: -9.0 +4.5
2295 + make deviating number of phes unsuitable (see David's findings).
2296
2297 - callisto: fixed the display of unsuitable pixels. The old change
2298 to a real profile in MHCamera broke it.
2299
2300 - callisto: The cosmics filter is used in MJCalibration now
2301 independant of the pulser color (formaly it was used only for
2302 CT1-pulser data). The threshold of number of max empty pixels
2303 has been raised from 2% to 5% in MJCalibration. The maximum
2304 fraction of rejected event is 50% otherwise the calibration has
2305 failed. The filter now ignores unsuitable pixels.
2306 Setup the filter from callisto.rc using "ContCosmics"
2307 (see MFCosmics::ReadEnv)
2308
2309 - callisto: changed default for fgOffsetFromLogain back
2310 from -2.8 to -1.8 in digital filter.
2311
2312 - callisto: for the common extractors
2313 + MExtractFixedWindow
2314 * MExtractTimeAndChargeSlidingWindow
2315 * MExtractTimeAndChargeSpline
2316 * MExtractTimeAndChargeDigitalFilter
2317 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2318 and fResolutionPerPheLoGain
2319
2320 - callisto: Updated the hi-/lo-gain intercalibration constants
2321 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2322 hilocalib_df6.root
2323
2324 - callisto: The default lo-gain extraction window for the
2325 MExtractTimeAndChargeSlidingWindow extractor has been increased
2326 from 6 to 8 to take the stretch of the pusle into account
2327
2328 - callisto (!!!): fixed an important bug in the setting of the
2329 incoming pedestal pointer to the signal extractor extracting
2330 pedestals. This bug caused the pedestals not to be subtracted
2331 correctly in the calibration afterwards. The effect was about 10%
2332 too high conversion factors for the digital filter and the spline
2333 and more than 40% for the sliding window.
2334 The bug existed since end of February! (Markus G.)
2335
2336 - star: added muon support to star. A new tab "MHMuonPar" is
2337 displayed. The lower right plot is an estimate of the point spread
2338 function. A reference value is displayed. To get the real PSF
2339 you must compare with MC. The setup for the muon analysis
2340 is done in star.rc. More informations can be found in
2341 MHSingleMuon and MHCalibParCalc
2342
2343 - star: The weather data is now displayed in star
2344
2345 - star: MEventRateCalc handles the calculation of the event rate more
2346 accurate now in case of the start of a new run inside a sequence
2347
2348 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2349 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2350 changed only minimally
2351
2352 - ganymed: (MJCut and MJOptimize) now displayes the number of
2353 excess events versus size. The energy estimation is done in
2354 MJSpectrum (sponde)
2355
2356 - ganymed: got support for using other variables than Alpha, eg. Theta.
2357 Therefor you need a class deriving from MHAlpha which supports
2358 this variable (one is already existing: MHTheta, which is now the
2359 default in ganymed). It is setup through ganymed.rc
2360
2361 - added a full featured spectrum program (sponde) which reads
2362 ganymed output and monte carlos and compiles a spectrum
2363
2364
2365
2366 *** Version 0.9.1 (2005/04/14)
2367
2368 - Fix bug on the arrival time reconstruction when using Digital
2369 Filter (in some marginal cases (10%) times were reconstructed shifted
2370 by 0.2 slices)
2371
2372 - all executables now return 2 where in previous versions -1 has
2373 been returned (gave problems with shell-scripts)
2374
2375 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2376 also done with a intercalibration input file
2377
2378 - a bug in the time fine adjustment of the digital filter has been fixed
2379
2380 - a lot of small fixes to calling TPad::Divide with a margin==0
2381
2382 - MStatusDisplay now shows the memory usage
2383
2384 - added a memory leak statistic after the eventloop
2385
2386 - MHadronness replaced by MParameterD
2387
2388 - MEnergyEst replaced by MParameterD
2389
2390 - wobble mode can now be switched on from the data-set
2391
2392 - switched on bad pixel detection for a pedestal level
2393 which is more than 5 times the variance
2394
2395 - Fixed default paths to be correct for the new data center
2396
2397 - Fixed handling of drive data. The pointing position in now
2398 copied to MPointingPos inside star for real and MC events
2399
2400 - made sure, that the sequences in a dataset are sorted by
2401 their number to ensure the correct synchronization
2402
2403 - added all resource files necessary to handle spline extraction
2404 of signal for the late 2004 and the early 2005 data
2405
2406 - update the reference lines for the december data
2407
2408 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2409 This is important for the Dec. and Jan. data where the calibration
2410 pulse position changes much.
2411
2412 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2413 filter. This corrects only an defective extraction of the MC at
2414 low-gain signals lower than 90 phes.
2415
2416 - fixed some slowdown in calibrating data with interleaved events from
2417 Jan and Dec. As a workaround made the pretty palette the default.
2418 The inverse Deep Blue Sea has a bug which slows down long calibration
2419 runs a lot.
2420
2421 - implemented new values from new starguider report as defined
2422 in TDAS00-07 V7.1 (eg SkyBrighness)
2423
2424 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2425 in starguider report (If you merpp the same reports with this version
2426 you'll get the correct units (arcmin) but a different result
2427 than with old versions (wrong units))
2428
2429 - Now the status display can also write PNG, JPEG and XPM (other file
2430 formats are still unsupported by root)
2431
2432 - added a lot of scripts and macros in directory datacenter used
2433 for automatic processing
2434
2435
2436
2437 *** Version 0.9 (2005/03/23)
2438
2439 - Calibration is now done autmatically into photo-electrons like
2440 decided by the Collaboration Board
2441
2442 - Reference lines in the display can be read from resource file
2443
2444 - Interlaced calibration events can be handled by callisto
2445
2446 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2447 and applied in callisto.
2448
2449 - class MJCalibTest can be called by callisto
2450
2451 - callisto can now run with three data types: rawdata, rootdata, MC
2452
2453 - added two classes mreport/MReportStarguider.cc and
2454 mreport/MReportStarguider.h for implementing starguider-data
2455
2456 - the output of merpp-update now contains starguider information:
2457 MReportStarguider and MTimeStarguider
2458
2459 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2460 values were lower than they should. This was more visible for high
2461 energy (Size) events.
2462
2463 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2464
2465 - added a new loop to callisto to support the correct extraction of
2466 the pedestal and pedestal rms through the signal extractor
2467
2468 - added class to perform fourier tranformation of a hexagonal structure
2469 (MHexagonalFT)
2470
2471 - added class to perform fourier tranformation of a hexagonal structure
2472 in a tasklist (MHexagonalFTCalc) example: hft.C
2473
2474 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2475 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2476 small pixels, example: extendcam.C
2477
2478 - added possibility to write data to memory (TTree) using MWriteRootFile
2479
2480 - added possibility to read a TTree stored only in memory by MReadTree
2481
2482 - new classes to deal with the interleaved calibration events:
2483 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2484
2485 - implemented filters to callisto to skip calibration events
2486
2487 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2488 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2489 the slices by statistics
2490 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2491 signal extractor without randomization
2492 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2493 with the signal extractor with randomization (extraction window is
2494 randomly fixed)
2495 The three kind of pedestal is not yet implemented (for speed reasons) as
2496 long as nobody really needs it:
2497 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2498 extracted with the signal extractor with randomization
2499
2500 - callisto now finds the pulse position in the data automatically
2501
2502 - implemented data reduction in calibrated data by reducing the precision
2503 of the stored floating point values (pedestal, rms and signal) to
2504 roughly 0.5%
2505
2506 - fixed showplot to make file format conversion (eg. converting a
2507 status display stored in a root file into a postscript file) in
2508 batch mode possible:
2509 showplot -b --save-as-ps[=outfile.ps] infile.root
2510
2511 - Allow class names as part of filter rules, eg
2512 (MFSupercuts) && (MHillas.fSize>100)
2513
2514 - fixed a lot of stuff to allow all programs to process MonteCarlo
2515 camera files.
2516
2517 - enhanced possibility to debug reading of resource file
2518
2519 - MDataChain should handle priorities of operator more
2520 accurate now
2521
2522 - completely revised the container in which the signal is stored
2523 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2524 * the new implementation is faster and
2525 * needs less storage space
2526
2527 - FIRST version which can process Monte Carlos through the
2528 whole chain of programs (callisto, star, etc)
2529
2530 - implemented new image parameters for the border length of
2531 the shower image (MNewImagePar2)
2532
2533 - implemented wobble-mode in ganymed
2534
2535 - new class (MJOptimize) taking care of all optimization processes
2536
2537
2538
2539 *** Version 0.8.6 (2004/10/05)
2540
2541 - New combined signal and time extractor
2542 MExtractTimeAndChargeDigitalFilter
2543
2544 - The Report for the trigger section in the CC run summary has been
2545 updated, and now the IPRs (Individual Pixel Rates) are available.
2546
2547 - new macros for database interaction: filldotrun.C, filldotrbk.C
2548
2549 - added new program which can convert colored output which was redirected
2550 into a file back into colored text (for example to display it with
2551 more): showlog
2552
2553 - added new program to display an MStatusArray of plots (stored with
2554 MStatusDisplay) from a file: showplot
2555
2556 - Added support for Sequences (MSequence). Sequences are blocks of run
2557 files containing the same calibration and belonging to the same
2558 source
2559
2560 - Added a new task (MTaskEnv) which can be used in setup files to switch
2561 between different tasks (for example to choose a signal extractor)
2562
2563 - Implemented automatic file splitting in MWriteRootFile
2564
2565 - After image cleaning an island index is assigned to all used pixels.
2566 The index corresponds to the order of the islands in size.
2567
2568 - added a cleaning which takes signal height _and_ arrival time into
2569 account: probability cleaning (for more details see MImgCleanStd)
2570
2571 - added a cleaning which takes takes the absolute number of photons
2572 times the area ratio as cleaning level
2573 (for more details see MImgCleanStd)
2574
2575 - Changed calculation of image parameters such, that it can be done
2576 for all used pixels or the pixels with a defined island index only
2577
2578 - implemented new image parameters displaying the number of islands,
2579 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2580
2581 - event display in executable changed to support also calibrated files
2582 (done with MJCalibrateSignal)
2583
2584 - added program doing the calibration and the signal extraction
2585 and signal calibration: callisto Most part of the setup is done
2586 by a resource file: callisto.rc
2587
2588 - implemented support for pixels with negative IDs (Raw file format
2589 version 4)
2590
2591 - implemented an new option in merpp (--auto-time) to get the time
2592 range for cc and/or caco data from the run header of the raw data
2593
2594 - New star-program (star and MJStar). Taking calibrated data from
2595 callisto/MJCalibrateSignal as input. The setup is done through
2596 a resource file: star.rc
2597
2598 - Added possibility to setup the eventloop in the mars-executable
2599 Camera Display by a resource file: mars.rc
2600
2601 - The the mars-executable Camera Display can now also read
2602 calibrated data files written by callisto/MJCalibrateSignal
2603
2604 - Added a new class which can calculate the source position in
2605 the camera from a pointing model known to be correct and
2606 the pointing model used for observations (MSrcPosFromModel)
2607
2608 - added a new version of the class calculating the effective on-time
2609 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2610 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2611 MHTimeDiffTheta.
2612
2613 - added the possibility to count how often a signal is above (or
2614 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2615 can replace MHTriggerLvl0)
2616
2617 - added ore convinient ways to set the axis-titles of your histograms
2618 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2619 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2620
2621
2622
2623 *** Version 0.8.5 (2004/08/06)
2624
2625 - new Signal Extractors: MExtractFixedWindowSpline
2626 and MExtractAmplitudeSpline
2627
2628 - implementes interleave in merpp to be able to merpp parts of a file
2629
2630 - implemented force-functionality to merpp
2631
2632 - star display to display star catalogs (MAstroCatalog)
2633
2634 - star display to 'mirror' stars to the camera (MAstroCamera)
2635
2636 - implemented a new cleaning option which allows cleaning scaled with
2637 the real ratio of the rms depending on the pixel size, not only the
2638 square root of the pixelsize (MImgCleanStd, MCameraData)
2639
2640 - removed obsolete MBlind* classes
2641
2642 - Signal extractor taking the AB flag into account implemented (this makes
2643 an odd number of slices for signal extraction possible
2644 (MExtractSignalABcorr)
2645
2646 - implemented a class extracting the pedestal from the raw-data (events)
2647 itself using empty lo-gain (MpedCalcFromLoGain)
2648
2649 - Added mean values to MPedPhotCam
2650
2651 - Added Makefile for Darwin (this OS is NOT officially supported!)
2652
2653
2654
2655 *** Version 0.8.4 (2004/04/19)
2656
2657 - new fast arrival time extractor using cubic splines:
2658 MExtractTimeFastSpline
2659
2660 - implementes multi-argument support in MDataChain
2661 ("pow(a, b)")
2662
2663 - implemented double reference support in MDataChain
2664 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2665
2666 - added support in MF for expressiond like
2667 "MHillas.fWidth<2*<MHillas.fLength"
2668
2669 - MDataChain is now able to support variables like [0], [1], ...
2670 which can be used in fit functions as parameters. The interface
2671 is implemented through the new virtual function
2672 MParContainer::SetVariables
2673
2674 - added new class MArrivalTimeCam/MArrivalTimePix:
2675 Storage containers to hold the ArrivalTime of the camera/pixel
2676
2677 - added new classes for the calibration of relative arrival times:
2678 MCalibrationRelTimePix and MCalibrationRelTimeCam
2679
2680 - added new classes to extract the signal of the blind pixel and the
2681 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2682
2683 - added new classes for the bad-pixels treatment (MBadPixels*)
2684 which are more powerfull than the old ones (MBlindPixel*)
2685 and will replace them.
2686
2687 - added filter against cosmics: MFCosmics
2688
2689 - added new class MArrivalTimeCalc2:
2690 Calculates the arrival time as the signal weighted mean of the time
2691 slices in the maximum window
2692
2693 - added a new macro call pointspreadfucntion.C that fits with a 2D
2694 gaussian the DC spot for an star. It gives you the RMS of
2695 the PSF and the center of the star, very useful for misspointing
2696 studies.
2697
2698 - added support for multi-telescope camera files. Added classes
2699 MStereoCalc and MStereoPar, classes to calculate and store shower
2700 parameters calculated from the data of two telescopes, for the MC
2701 studies regarding the MAGIC clone.
2702
2703 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2704 MC data calibrated in photons instead of ADC counts.
2705
2706 - added three macros to show the calibration and analysis chain of
2707 MC data. The macro starmc.C does both calibration and analysis, producing
2708 an output containing Hillas parameters for each event. The macro
2709 mccalibrate.C does just the calibration and writes out a file containing
2710 pixel information in photons instead of FADC data. The macro starmc2.C
2711 reads in such a file and produces an output with Hillas parameters.
2712
2713 - added MPedPhotCalc to compute pedestals in units of photons, see
2714 macro pedphotcalc.C
2715
2716 - added all class to perform the calibration, see macro calibration.C
2717
2718 - added class MFFT to perform Fast Fourier Transforms
2719
2720 - added class MSimulatedAnnealing to perform simulated annealing
2721 minimizations
2722
2723 - added new macro bootcampstandardanalysis.C which holds the skeleton
2724 of the analysis chain discussed in the december bootcamp.
2725
2726 - added support for DAQ raw data file format V2
2727
2728 - implemented an arbitrary time stamp for the events from raw-data
2729 files with file version<3. It is calculated from the run number,
2730 the date of start and the FADC clock tick from the first module
2731
2732 - implemented the correct decoding of the event time-stamp
2733 coming from the DAQ for raw-data files with file-version>2
2734
2735 - added a new classes storing the pedestals in units of photons:
2736 MPedPhotPix, MPedPhotCam
2737
2738 - added support for DC current files from the camera control
2739
2740 - added support for start- and stop-time when merpping report files
2741
2742 - added MReportCC storing the weather data from the CC-REPORT
2743
2744 - added class to fill trainings and test matrices (MTFillMatrix)
2745
2746 - added a filter performing a software trigger (MFSoftwareTrigger)
2747
2748 - Added classes to perform parts of the standard analysis (Jobs):
2749 + MJPedestals
2750 + MJCalibration
2751 + MJExtractSignal
2752 Note: All of them are preliminary!
2753
2754 - Added Iterator to iterate over files giving only the run-number
2755
2756 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2757 the evolution of a sector vs time
2758
2759
2760
2761 *** Version 0.8.3 (2003/12/05)
2762
2763 - adapted Random Forest classes to allow the use with MC
2764 multi-telescope files which can be produced with the coming
2765 camera version 0.7.
2766
2767 - added classes to read and interprete central control report files
2768 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2769
2770 - enhanced merpp (the executable) to support .raw and .rep files.
2771
2772 - added classes for light calibration (MCalibration* and
2773 MHCalibration*) by Markus Gaug. Further work has to be and will
2774 be done soon.
2775
2776 - Added a preliminary 'synchronizer' (MReadReports) which will
2777 replace MReadMarsFile as soon as it is finished.
2778
2779 - Added a tutorial macro demonstrating how report files are merpped
2780 and how they can be read from the root file in the correct order
2781 of time (readrep.C)
2782
2783 - Added a generalized histogram (similar to MH3) called MVsTime
2784 which allows to plot variables (or rules - MDataChain - of
2785 variables) vs time. For an example have a look at tempvstime.C.
2786
2787 - Changed the name of the event trees:
2788 + Events --> Events
2789 + PedEvents --> Pedestals
2790 + CalEvents --> Calibration
2791
2792 - changed name of MTime in the event trees from MRawEvtTime to MTime
2793
2794 - added displaying the sector indices to the mars event display
2795
2796 - Magic Online Analysis (MOnA) implemented in a first version
2797 (see mona.cc, MOnlineDump and MOnlineDisplay)
2798
2799 - added classes to calculate event rate
2800 (preliminary: MEventRateCalc, MEventRate)
2801
2802 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2803
2804 - added classes dealing with the telescope pointing position (MPointing*)
2805
2806 - implemented the 'final' Mars time stamp based on some experiences with
2807 the new 'Synchonizer'
2808
2809
2810
2811 *** Version 0.8.2 (2003/11/10)
2812
2813 - accelerated standard analysis by a factor of 6-8 ...
2814 + doing precalculations in MGeomCam for the pixel area ratio
2815 + creating a look up table for the single pixels in MCerPhotEvt
2816
2817 - added task to calculates weights in case you want to 'change'
2818 the energy spectrum of a monte carlo file
2819 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2820
2821 - added a new executable star which implements the
2822 star.C macro as precompiled executable. Currently a flexible
2823 setup is not possible, but a 'input card' setup will follow.
2824
2825 - Starting to implement Multi-Telescope-Support based on the
2826 upcomming camera version 0.7. The base for a general support
2827 is implemented and the star-functionality is proven to work.
2828
2829 - Replaced Event-Display in and Camera-Display in the Mars GUI
2830 executable by a more convinient display base on MStatusDisplay.
2831
2832 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2833
2834
2835
2836 *** Version 0.8.1 (2003/10/20)
2837
2838 - added signal subtraction for pure on data by means of fitting
2839 the background in the off region or by performing a combined
2840 signal/background fit. Provides necessary histograms for
2841 obtaining energy spectra and a light curve.
2842
2843 - added classes to perform and study the selection of the
2844 2nd Level Trigger on MC data (example in triglvl2.C macro)
2845
2846 - added pedestal calculation
2847
2848 - implemented "democratic cleaning" (tail cut value proportional
2849 to pixel area) according to Wolfgang's suggestion.
2850
2851 - added Sigmabar treatment (calculation and basic histogramming)
2852
2853 - added basic routines to apply padding
2854
2855 - added first implementation of MARS-based source visibility plotter
2856 (needs to be linked against slalib, preliminary version)
2857
2858 - enhanced functionality of data chains: random numbers, conversion
2859 functions and access to MHMatrix objects
2860
2861 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2862 numbers under certain circumstances (runs with 0 events included)
2863
2864 - fixed a bug in the general filter MF (didn't work on some systems
2865 at all)
2866
2867 - fixed a bug in chaining files, which caused the analysis to crash or
2868 ignore files
2869
2870 - implemented more geometry classes describing the parameters used
2871 to simulate the PMT camera
2872
2873 - added new Monte Carlo classes containing the setup of the different
2874 programs in the MC chain.
2875
2876 - added a (preliminary) general task to evaluate chi-square of a given
2877 parameter in an eventloop.
2878
2879 - first implementation of a container describing the observatory
2880 location (Long, Lat, etc)
2881
2882 - added Random Forest - method for g/h-separation
2883
2884 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2885 (this means, that it is compiling, but not yet fully tested)
2886
2887 - added a new status display which can show the present status
2888 of histograms while an eventloop is running (MStatusDisplay,
2889 an example can be found at status.C)
2890
2891 - reorganized directories:
2892 classes describing the image --> mimage
2893 classes containing Monte Carlo Histograms --> mhistmc
2894 classes for Random Forest method --> mranforest
2895
2896 - added (event-)weights to fill histograms
2897
2898 - colors in logging output to screen
2899
2900 - changes to the Image Parameter declaration:
2901 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2902 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2903 + MHillasExt now derives from MParContainer instead of MHillas
2904 --> Files written with the old definition are more or less unreadable
2905
2906 - reading of reflector files
2907
2908 - display data from reflector files in the camera
2909
2910 - implemented currents (and display them in the camera)
2911
2912 - logarithmic scale in camera
2913
2914 - added class to iterate through directory contents (MDirIter)
2915
2916
2917
2918 *** Version 0.8 (2002/11/18)
2919
2920 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2921
2922 - corrected 48(!) wrong entries in the Next Neighbor table of the
2923 Magic Camera (all in the inner part of the outer ring, mostly
2924 missing a single NN)
2925
2926 - Fixed a bug in the table describing the Next Neighbours of the
2927 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2928 have any neighbour)
2929
2930 - changed trigrate.C: now it calculates the pure NSB triggers from
2931 a camera file (generated with no showers), so there is no need
2932 to introduce them by hand in the BgR array (for more details
2933 please ask Abelardo)
2934
2935 - added MHHadronness (and MHadronness) as a general facility to evaluate
2936 the quality of a gamma-hadron seperation method
2937
2938 - changed MWriteAsciiFile to accept rules (MDataChain)
2939
2940 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2941 must be replaced by calles to MWriteAsciiFile::AddColumn and
2942 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2943 changed.
2944
2945 - Implemented generalized event-matrices (one row per event)
2946 (MHMatrix)
2947
2948 - implemented the one dimensional composite probabilities
2949 (MHCompProb, MCompProbCalc, comprob.C)
2950
2951 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2952 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2953
2954 - Added a camera display displaying the pixel numbers to the
2955 event display gui.
2956
2957 - Added Monte Carlo Informations to event display gui
2958
2959 - Changed the camera display to display the pixel numbering
2960
2961 - Added three buttons to the camera display to change the palette
2962
2963 - Added the number of used and core pixels after image cleaning
2964 to MHillas
2965
2966 - Changed the algorithm used in MHillas according to TDAS 02-03
2967
2968 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2969
2970 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2971
2972 - Added fCosDeltaAlpha to MHillasSrc
2973
2974 - The numbers of photons used to calculate fConc and fConc1 in
2975 MHillasExt are now scaled with the pixel size, so that one get
2976 a four times smaller value for the bigger pixels in the outer ring.
2977
2978 - added new task to smooth the camera contents (MCameraSmooth)
2979
2980 - added possibility to use interpolated pixel values for blind pixels
2981 instead of removing it completely from the analysis
2982
2983 - Implemented the possibility to save the whole eventloop with
2984 its setup to a file. This information can be read and from
2985 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2986 and MEvtLoop::MakeMacro. If you find something not working, please
2987 report - this stuff is still in a beta phase.
2988
2989 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2990 file having crab starfield, but also for all following files - fixed
2991
2992 - MTaskList::PrintStatistics can now be instructud to print also the
2993 title, too: use PrintStatistics(0, kTRUE)
2994
2995 - Changed the image cleaning so that pixels with to many 'used'
2996 neighbors are left used (to get rid of 'holes' in events)
2997
2998 - Introduced more output to the camera displays
2999
3000 - Added an array of histograms (eg one hist per run), MHArray
3001
3002 - Added a _preliminary_ version of the reader for CT1 PreProc files
3003 (MCT1ReadPreProc)
3004
3005 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3006 (thanks to Raquel)
3007
3008 - added the first energy estimator (MEnergyEstParam, estimate.C,
3009 estfit.C) using a parametrization
3010
3011 - Added some new Monte Carlo paremeter containers used to store
3012 setup information from the MC chain (MMcConfigRunHeader,
3013 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3014
3015
3016
3017 *** Version 0.7 (2002/04/30)
3018
3019 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3020 the pedestal mean value was saved incorrectly. For files from
3021 this versions we substract 0.5 from the pedestal mean.
3022 WARNING: This may effect your results, so don't wonder...
3023
3024 - First implementation of an algorithm using only triggered events
3025 for the collection area calculation
3026
3027 - Ascii Output can now also be used for parameter containers which
3028 doesn't overload MParCointainer::AsciiWrite
3029
3030 - The Ascii Output is now also capable of writing single data members
3031 of one container
3032
3033 - You are now able to change the order of the values written to the
3034 ascii file
3035
3036 - You can now specify a conversion factor for each data member written
3037 to an ascii file. This may be usefull to change the units of the
3038 data member (eg. degrees instead of millimeters in case of the
3039 hillas parameters)
3040
3041 - Replaced old MHillas by a new structure which allows you to extend
3042 the parameters stored in MHillas very easily:
3043 see MHillas and MHillasExt
3044
3045 - Added classes to handle source dependancy of image parameters:
3046 see MHillasSrc
3047
3048 - Added container (MBinning) to have a standard input for the binning
3049 in different histograms (eg. the Energy bins should be the same in
3050 all histograms)
3051
3052 - Changed Hillas histograms from mm to deg
3053
3054 - Added the flexible binning to the hillas histograms
3055
3056 - Added a filter for the alpha parameter (MFAlpha)
3057
3058 - It is now possible to write single data members of a class object to
3059 an output stream instead of the whole container only
3060
3061 - Added a generalized filter for a data member:
3062 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3063
3064 - Added a generalized Filter parser for more difficult filter rules
3065 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3066
3067 - Added new Monte Carlo histograms:
3068 MHMcEnergyImpact and MHMcEfficiency
3069
3070 - Added many new histograms needed for the flux calculation.
3071
3072 - Added a generalized histograms which can fill and show up to three
3073 data members in either a one-, two- or three-dimensional histogram, eg:
3074 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3075
3076 - Added:
3077 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3078 * calculation of <Theta> as a function of time (MHThetabarTime)
3079 they are needed in the flux calculation in
3080 order to select for a given bin in Theta (or time) the appropriate
3081 effective collection area, which is assumed to be given as a function
3082 of Theta and the true energy
3083
3084 - Added calculation of the migration matrix in the energy
3085 (MHMcEnergyMigration):
3086 the migration matrix describes the migration from the true (E_true)
3087 to the estimated energy (E_est); it is needed to determine the
3088 distribution of E_true from the measured distribution of E_est
3089 by unfolding
3090
3091 - changed the color palette in the camera display to DeapSea.
3092
3093
3094
3095 *** Version 0.6 (2002/01/15)
3096
3097 - Introduce the option of disable pixels (MBlindPixels and
3098 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3099 able to deal with Star Field NSB.
3100
3101 - Fixed a bug in the pedestals substraction
3102
3103 - Introduced verbosity levels
3104
3105 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3106
3107 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3108 work correctly (thanks to Abelardo)
3109
3110 - Introduced correct treatment of the diffuse Night Sky Background
3111 and NSB (MMcPedestalNSB)
3112
3113 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3114
3115 - Introduced MMcRunHeaders which contains monte carlo run informations
3116
3117 - Added a 'Print'-Task (MPrint) which calls the Print function
3118 of a parameter container for each event
3119
3120 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3121
3122 - changes to be more efficient with root 3.02/06
3123
3124 - root 3.02/06 fixes:
3125 + the memory leak when reading MRawEvtData
3126 + loosing more time than necessary to update the progress bar
3127
3128 - MWriteAsciiFile is now capable of writing more than one container
3129 in a line. For example: To be able to write Monte Carlo and
3130 Hillas values (energy and alpha) in one line.
3131
3132
3133
3134 *** Version 0.5 (2001/11/06)
3135
3136 - Added new GUI functionality (Analysis)
3137
3138 - Added a camera display to be able to display events in the camera
3139 together with the calculated hillas ellipse
3140
3141 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3142 object at any state of the analysis, so that the output are several
3143 states
3144
3145 - Fixed a bug in the collection area error calculation
3146 (Thanks to Ciro and Abelardo)
3147
3148 - Fixed a bug which causes merpp to crash in some environments
3149
3150 - Implemented auto enabling scheme for Branches to speed up reading
3151 a lot (see MReadTree and MTask)
3152
3153 - Fixed a bug in the Histogram classes which caused histograms to
3154 be written to a file by MWriteRootFile without request
3155
3156 - changed the object I/O from the old stylish root I/O to the new
3157 'auto evolution scheme' This was done only for classes which are not
3158 yet used in Monte Carlo files, so that these files are still readable.
3159
3160 - Added support for a progress bar in MEvtLoop and MReadTree
3161 (see the Analysis Window in Mars for an example)
3162
3163 - Fixed a bug in the package creation which disturbed the conversion
3164 between a mars version unpacked from a tar file and the repository.
3165
3166 - Changed the code to writer merpped (converted into root format)
3167 raw files, to get faster (around 10%)
3168
3169
3170
3171 *** Version 0.4 (2001/09/20)
3172
3173 - This release is made to compile on a root version >= 3.00
3174
3175 - Fixed a bug which causes MReadTree to read the first file only
3176
3177 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3178
3179 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3180
3181 - Added a task to write several container to a root file (MWriteRootFile)
3182
3183 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3184
3185 - Added calculation of the collection area (MMcCollectionAreaCalc)
3186
3187 - fixed some bugs in the Hillas calculation
3188
3189 - added filters to be able to control the task execution dependent on
3190 a parameter (for example: the number of level 1 triggers in a MC-file)
3191
3192
3193
3194 *** Version 0.3 (2001/04/23)
3195
3196 - Many demo macros added
3197
3198 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3199
3200 - Hillas Calculation added
3201
3202 - Standard image cleaning available
3203
3204 - MReadTree is now able to handle more than one file
3205 (Remark: of the same structure)
3206
3207 - Now we are able to display events in a first version of the
3208 Camera event display. To do this we must run the macro
3209 "macros/readCT1.C" to read data from CT1.
3210
3211
3212
3213 *** Version 0.2 (2001/01/24)
3214
3215 - First Implementation of a Gui to read the raw data. Start the
3216 gui with the command mars.
3217
3218
3219
3220 *** Version 0.1 (2000/12/20)
3221
3222 - First official release 0.1
3223
3224 - Changes:
3225
3226 + changed calling style of MRawPixelIterator from do...while to
3227 while-loop
Note: See TracBrowser for help on using the repository browser.