source: trunk/MagicSoft/Mars/NEWS@ 9384

Last change on this file since 9384 was 9369, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 131.5 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;SUGGESTION
6
7 * There is no need to re-run any data because no change took place which
8 could have an effect on the output. However, if you want a
9 meaningful SrcPos plot for your MCs in sponde you must re-process
10 star for your MCs first.
11
12 ;general
13
14 * fixed a few small bugs which could cause the display to crash in ganymed
15 and sponde
16
17 * in sequence file the date can now be omittet. In this case the
18 leading date with the underscore is missing in the expected filename
19
20 * the geometry class now also supports other geometries than just hexagons
21
22 ;automation
23
24 * added magnetic field Azimuth direction (ARRANG), currently
25 at ~ -7deg at La Palma
26
27
28 ;database
29
30 * plotdb.php: added default (sequences) for startup, added possibility
31 to set size of plot
32
33 ;merpp
34
35 * added support for Arehucas Version >= 200812140
36
37 ;mars
38
39 * The display now also displays the trigger pattern
40
41 * The display can now display ceres reflector (_R_) files
42
43 ;ceres
44
45 * added a uniformly distributed one-bin time jitter for the start of the
46 digitization. Otherwise the first photon would be digitized always with
47 the same alignment to the bins
48
49 * Added a plot showing the production height of the photons
50
51 * Moved the particle id from the event header to the run header
52
53 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
54
55 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
56
57 * Added many new options to control the tasks. For deatils see ''ceres.rc''
58
59 * Removed obsolete plots in pedestal and calibration mode
60
61 * Removed the non-NightSky photons from the plots where they are just
62 disturbing
63
64 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
65
66 * The daq event number now represents the readout number
67
68 * The camera ''electronics'' can now be ''switched off''
69
70 * A new tab ''Info'' now display basic things like the reflector
71 layout
72
73 * Improved reading speed for corsika files
74
75 * Improved memory handling (if a large ampount of memory was needed
76 for a single event all further events were stored in the same
77 memory and it was never freed, so the program took this memory
78 until the end)
79
80 * Converted the code from MMCS' reflector program to MSimAtmosphere
81 (instead of the tables build in for MAGIC Winter and Summer
82 atmosphere we use the values written by Corsika fitted to the
83 tabulated atmosphere given as input)
84
85 * For caluclating the displayed image parameters in ceres a basic
86 image cleaning removing isolated pixels is now done.
87
88 * The magnetic field direction (ARRANG) is now taken into account
89
90 * Added plot for the energy threshold after trigger ''Threshold''
91
92 * Added plot for the effective collection area after trigger ''TrigArea''
93
94 ;star
95
96 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
97
98 * The definition of fConcCore has slightly changed. The numbers
99 might decrease a little bit (the effect should be rather small)
100
101 ;ganymed
102
103 * added pointing model 328198
104
105 ;sponde
106
107 * The SrcPos plot for your MCs was so far meaningless because it just
108 displayes the MSrcPosCam data from the input star-files. Unfortunately,
109 this containes was never written to the star-files yet.
110
111 * A new Tab 'OnTime' is available which is an effective on-time
112 fit as in star but for all data. This is mainly for manual cross-check
113 of the effective on-time
114
115 * In some circumstances it might be necessary to re-calculate the
116 eff. on-time from the fit in the new tab, e.g. when a zenith distance
117 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
118
119 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
120 it to its own output file (for convinience)
121
122
123
124== Version 2.2 (2009/01/30) ==
125
126 ;SUGGESTION
127
128 * This release doesn't contain a major change which is expected to
129 change your results. Nevertheless there are small changes to
130 the calibration which can effect at least the first few hundred
131 events in any (mainly MUX and even more SUM) sequence a little bit.
132 So it is recommended although not necessary to reset your sequences
133 in the database before further processing.
134
135 ;NEW
136
137 * A first implementation of a Monte Carlo simulation program
138 (ceres - Camera Electronics and REflector Simulation) has been
139 implemented. It can simulate a full telescope already including
140 a complete reflector simulation and a flexible trigger and readout
141 simulation. Currently, no perfect setup is implemented and
142 especially the output of the program (data structure) should
143 be considered alpha state. Also the user interface is not yet
144 ready.
145
146 ;general
147
148 * All command line options after -- are now interpreted as
149 arguments (usually everything which doesn't start with a minus)
150 rather than options (usually everything which starts with a
151 minus). This allows to use file names starting with a -
152
153 * In all resource files you can now initialize the random number
154 generator. For details see: MJob::InitRandomNumberGenerator
155
156 * added a new program called ''readcorsika''. It's purpose is (in analogy
157 to readraw and readdaq) to read a Corsika output file (for now
158 only cherenkov output is supported) and print its contents in a
159 human readable form. It can also write the contents of this file
160 into a root-file.
161
162 * The calculation of the maximum distance to the origin in a MGeomCam
163 has been improved (edges might be further away than the sides).
164 This is just a tiny change but it might change the appearance of
165 the radial profiles a little bit.
166
167 * The default binning of the center-of-gravity plot has slightly been
168 increased
169
170 ;Database
171
172 * Added informations about the DC currents (fMinCurrents, fMedCurrents
173 and fMaxCurrents). The values are retrieved from the plots showing
174 the average DC currents of all pixels versus time.
175
176 * Websites with tables have now the opportunity to remove lines
177 ('-' button at beginning of each line) and get all lines back
178 ('+' at top of the column)
179
180 * Websites: added option to query only sequences containing sumtrigger
181 events
182
183 * Websites: added option to group by date (year, month, night) for runs
184 and sequences and enabled that combining of different group-bys,
185 e.g. status, date and source is possible
186
187 ;automatic analyis
188
189 * Rewritten producing plots in the web.
190 New plots, namely the output of plotoptical.C (extinction curve from
191 KVA), plotstat.C (status of the automatic analysis (percentage of
192 processed, analysed data etc.)) and plotusage.C (statistics of the
193 condor usage in the data center) has been are available now next to the
194 plots of plotdb.C
195 Mean values from the plots (output of the macro) are provided in a
196 txt file now.
197 The creation of the plots for callisto, star and ganymed in the web is
198 now steered via database. Consequently the plots are faster and
199 reliable up-to-date.
200 For all plots, a new layout is available facilitating the browsing
201 through the plots and providing additional information on the
202 displayed values. (tabs.php) These plots are linked from the DB
203 websites and the wiki.
204
205 ;statusdisplay
206
207 * The ''Loop'' entry in the menu bar now contains an option to pause
208 the loop and to process single events.
209
210 ;merpp
211
212 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
213 instead of RunHeaders)
214
215 * Now allows to merpp files newer than 2008/09/03.
216
217 * Added fixes for wrong (wrong or double) run- and file-numbers
218 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
219
220 ;callisto
221
222 * Extracting the pulse position for the pulse position check events
223 with sum trigger were denied. This decreased the statistics
224 extremely and therefor the resulting puse position was calculated
225 quite weak. Now sum events pass the calculation if and only if they
226 have also a level 1 trigger.
227
228 * the extraction of pedestal events and pulse position from the
229 first data events is now more automatic and makes sure that
230 a more precise number of events is extracted independent of
231 the ratio with which pedestal events or events with signals
232 are contained in the data.
233
234 * Updated Muon calibration constants for all MUX data (teh changes were
235 all smaller than 5%)
236
237 ;star
238
239 * For the calculation of the effective on time all sum-triggered events
240 were skipped. Now all Level1-triggeres events will pass. This might
241 result in a slight inaccuracy of the effective on time.
242
243 ;ganymed
244
245 * If the source position is more than 1deg away from the camera
246 center an error is raised now.
247
248 * Hopefully fixed the bug ''ganymed crashes when resized''
249
250 ;sponde
251
252 * Fixed a problem which causes the fitted spectral slope to be displayed
253 incorrectly. If you use MJSpectrum::FormFlux in your macros make
254 sure that the parameter 0 of your fit is negative.
255
256 * Added a histogram showing the read source position of your MCs
257
258
259
260== Version 2.1.1 (2008/08/04) ==
261
262 ;Database
263
264 * Added the median number of photo electrons from the calibration
265 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
266 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
267
268 * Added fTotOnTime, which is the on-time as given by the run-headers
269 (in contradiction to fAbsOnTime which comes from CC)
270
271 * Added new primaries for the new data structure (Magic II): for the
272 tables dealing with sequences (SequenceBuild Status, Sequences,
273 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
274 this is the telescope number (fTelescopeNumber) for the tables dealing
275 with runs (RunData and RunProcessStatus) this is in addition the file
276 number (fFileNumber)
277
278 * Added column fPriority to the status tables to be able to steer the order
279 in which the data is processed. As default the run, sequence and dataset
280 number are used.
281
282 ;automatic analyis
283
284 * Adapted scripts to the new data structure: They can handle now different
285 telescopes (getting the information as usual from the database).
286 The paths for Magic 2 are not yet implemented.
287
288 ;general
289
290 * should work now with root 5.20/00 (please note that root 5.20/00
291 we encounter crahses in the status display which are ot yet
292 understood)
293
294 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
295 instead of the base name of the file. This makes them easier to
296 access from the code
297
298 * Default Monte Carlo names in MSequence do not require the _E at
299 the end anymore
300
301 * where abrrevating a sequence file with a sequence number is possible
302 also "telescope:sequence" is now accepted, e.g.:
303 star 2:2000123 --out=output
304 see the programs' help for more details.
305
306 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
307 from the database. See the constructors for more details.
308
309 * MReadTree now supports friends
310
311 * MReadTree can now read also files not written by MARS and store
312 the data encapsulated in emulated MParContainers
313
314 * added a new starguider calibration valid since 15.1.08
315
316 ;showplot
317
318 * showplot can now read more than one file at once. This is especially
319 inetersting if reading files containing pure canvases
320
321 ;merpp
322
323 * we merpp the dc currents now also from the camera reports (they have
324 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
325
326 * In the automatic analysis we omit merpping of the currents from the
327 caco files and use the lower rate camera reports from the cc files
328 instead
329
330 * merpp has been redisigned to allow merpping of the cc-reports
331 of a whole sequence. This allows to design a very simple analysis:
332 mkdir output
333 ./callisto 100776 --out=output
334 ./merpp 100776 output
335 ./star 100776 --ind=output --out=output
336 Instead of the sequence number also sequence files are accepted.
337
338 * Implemented a fix for run-numbers between 1001348 and 1001396
339 which were incorrectly assigned by the cc.
340
341
342 ;callisto
343
344 * added a filter again which was was removed in the last release.
345 it removed the most brightest events. This should not change
346 any analysis result because these events are so bright that
347 they cannot be analysed anyway, but the bad-pixel plots doesn't
348 show outliers.
349
350 * updated muon calibration constants for the periods 51-57,
351 58-63 and 67-
352
353 ;star
354
355 * The camera currents are now displayed with the rate of the camera
356 reports instead of the caco reports
357
358 ;ganymed
359
360 * if mc camera files are new enough (>=8) the source position in the
361 camera is now calculated from the stored telscope and shower
362 orientation (Note, that this might not be suitable in all cases
363 depending on the aim of the study. These case still needs
364 implementation)
365
366
367
368== Version 2.1 (2008/06/18) ==
369
370 ;Database
371
372 * introduced average temperature and wind speed from star-files
373
374 * introduced average values from Pyrometer (mainly Cloudiness)
375
376 * introduced the ratio of accepted calibration events in the
377 calibration run
378
379 * introduced the average rates of the different trigger pattern,
380 e.g. the rate of pedestal and calibration events, from the signal-file
381
382 ;general
383
384 * fixed GroupBy options in plot*.C macros
385
386 * only display KVA points (not the Tuorla points) in plotoptical.C
387
388 * all programs now allow to add resources to the ones from the resource
389 file or overwrite them from the command line. This can be done like this
390 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
391 if something seems to be wrong you can debug what the program is doing
392 using the option --debug-env=3
393
394 * increased the diversity of debug levels. That also means that with -v3
395 you get now less output, i.e. only the output which is important for
396 an analysis. To get more output which helps for debugging try 4, 5 and 6.
397
398 * fixed a problem in the task synchronizing the reading of the reports
399 and the data stream. The effect was that in some circumstances the last
400 events of some trees could have been skipped. Since this is only a
401 very tiny part of the data no severe effect to your analysis results
402 is expected (an exception might be very short, i.e. singel runs,
403 datasets).
404
405 * Dataset file now allow to include the sequence file directly within
406 the dataset file and also allow to exclude single runs from the dataset.
407 (for more details see Class reference of MDataSet)
408
409 * Sequence files now allow for excluding runs from the analysis
410 (for more details see Class reference of MSequence)
411
412 * added code to process the sum-trigger flag
413
414 * the histogram classes MH3 and MHn now support profile histograms
415
416 * the histogram classes MH3 and MHn now support labels at the axis
417
418 * the Random Forest Train-classes (MJTRain*) now store the used datasets
419 in the output file
420
421 * the MFMagicCuts have a new option to allow a linear area cut (for
422 special studies)
423
424 * The liniking of the shared object is now done into a file defined
425 by 'mktemp'. This should be a local file system which accelerates
426 liniking a lot.
427
428 * The code has been prepared for compilation with root 5.18/00d
429
430 * The MHEnergyEst histogram now shows the distribution of
431 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
432 and (Eest-Emc)/Emc vs Emc.
433
434 * fixed mars (event display) for merpped raw-data and MC data
435
436 * adapted the synatx of sequence files to allow for the new run/file
437 scheme. For more details see class description of MSequence
438
439 ;showplot
440
441 * Added support for tiff files
442
443 * Added support for csv files (tables containing tab number,
444 name and title)
445
446 * Tabs now can have a title which is displayed in the postscript file
447
448 * When multiple file are written at once (e.g. pngs from a display)
449 it is now possible to use the tab name and or tab number in the
450 file name. For details see showplos's help.
451
452 ;merpp
453
454 * Implemented cc file version 2008-02-20/0
455
456 * Implemented cc file version 2008-05-19/0
457
458 * With new options merpping can be restricted (in addition to the
459 run-number) also by telescope and file number.
460 For details see "merpp --help"
461
462 * Implemented raw data format 11 (the most important change, except
463 from plenty of changes in the format definition, is the addition
464 of the file-number in the header) If nobody makes a mistake this
465 format should have the advantage that it is by definition forward
466 compatible, so old programs will be able to read newer formats.
467
468 * Added Pyrometer information to default output (stored in a new Tree
469 Pyrometer, needs a complete new merpp, i.e. new calibration)
470
471 * Merpping (also update) can now be restricted to one single report.
472 For example:
473 If you want to update an old file with Pyrometer information call
474 merpp --only=Pyrometer --update
475
476 ;callisto
477
478 * in the pedestal processing now at least 50 processed events are
479 required for succeeding.
480
481 * the signal and calib files now contain also the sequence information
482
483 * the two MPedestalCam in the calib file now have proper names
484 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
485
486 * Both pedestal cams now contain the number of events processed
487
488 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
489 i.e. for the extraction of the calibration pulses basically the average
490 over all events of the first slice instead of all slices was used.
491 Since pedestal and calibration constants are continously recalculated
492 this only effected the very first events of every sequence.
493
494 * For the extraction of the position of the maximum sample now the
495 extraction range is set automatically to the extraction window,
496 before the whole accessible range was used.
497
498 * If the number of samples in the events and the number of samples
499 in the run-header disagrees now an error is raised (this can
500 happen in not well simulated Monte Carlo files)
501
502 * In the case of MUX-data pedestal events with the lvl1 trigger flag
503 could survive into the pedestal calculation -- fixed.
504
505 * Tab "TrigPat" added showing the distribution of the trigger pattern
506 as found in the run-files (normalized with the run length)
507
508 * The selection of events from the trigger pattern has been improved.
509 If the trigger pattern is corrupted events won't pass anymore.
510
511 * Added a new command line option --dev-null to suppress output of
512 Y-files (this is useful for test cases)
513
514 * added a new tab "CalPos" showing the arrival time of extracted
515 interleaved calibration events
516
517 ;star
518
519 * the star file now contains also the sequence information
520
521 * Added a new command line option --dev-null to suppress output of
522 I-files (this is useful for test cases)
523
524 * Tab "Rate" added showing the distribution of the trigger pattern
525 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
526 the Y-files (normalized with the run length)
527
528 * The effective on-time calculation doesn't use events with only
529 sum-trigger anymore
530
531 * The data in the MHWeather tab has been reorganized. The never
532 working solar radiation has been removed and the data from
533 the pyrometer (cloudiness, air and sky temperature) is
534 displayed in addition.
535
536 ;ganymed/sponde
537
538 * Now data points are even shown correctly if they have error bars larger
539 than one sigma. Points with null or negative significances are omitted.
540
541 * DrawNicePlot now allows to set a projection range
542
543 * Updates pointing models. One is applied after the implementation
544 of the new LUTS in August, the other one is applied after the
545 next major change of the pointing model in October. Note that
546 these models are preliminary and give wrong results below Zd=65deg
547
548 ;sponde
549
550 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
551
552 * a new option "--force-runtime" is available. In case of very short
553 datasets (for light-curves) which are in the order of a few
554 minutes the calculated effective on-time is not very acurate because
555 it is quantizised in the order of a minute. Therefore you can switch
556 to using the real run-time instead (remakrt: this ignores any
557 dead-time!)
558
559 * a more analytical way is used to "fill" Monte Carlos into regions
560 of impact parameters which have not been simulated because the
561 trigger efficiency is assumed to be 0.
562
563 * estimated sensitivity curves for hi and lo zenith angles are shown
564 scaled to the correct observation time and collection area
565
566 * the Monte Carlo events after cuts are now written to the output file
567 if an output file given
568
569
570
571 *** Version 2.0 (2007/09/03)
572
573 - database: the position used for the pulse pos check was missing
574 in the callisto output and could thus not be filled into the DB.
575 Also the old values seemed not exactly the PulsePos used for
576 teh check.
577
578 - general: Resource file now allow an Include-Resource, i.e. you can
579 read a resource file with default settings, include it in your
580 resource file and overwrite the settings in your file. More than
581 one include file is allowed. Inclusions can be iterative.
582 Include: mydefaults.rc yourdefaults.rc
583 The resources in the first file have higher priority than the
584 second file.
585
586 - general: Now the output files (calib*.root, etc) also contain the
587 resource file (to check it open it in the TBrowser and choose Print()
588 from the context menu)
589
590 - general: Dataset files now allow to overwrite the default path
591 to search for sequence and data files. Note, that the program
592 option and individual resources will overwrite it. For example:
593 SequencePath: /magic/montecarlo/sequences
594 DataPath: /magic/montecarlo/star
595
596 - general: Fixed a problem with variables in MDataPhrase. It seems
597 that only optimdisp (didn't work) was effected.
598
599 - general: Some improvements to the optim and train processing. For
600 example the ststud window now got a proper title.
601
602 - general: The "Status Display: " was removed from the window title
603 within an Eventloop.
604
605 - general: added a new flexible histogram-class (MHn) which can be used
606 for example in testing after optimizations or training to produce
607 user defined histograms.
608
609 - general: The Random Forest now allows attaching an evaluation
610 function which is applied to its output. This allows to train
611 on whatever you like (eg. train on log10(energy), but return
612 energy)
613
614 - general: The Random Forest training of energy (trainenergy.c) and
615 disp (traindisp.C) has been improved by more graphical output to
616 judge the result.
617
618 - general: The training of energy (trainenergy.C) has been improved
619 a lot by training on a different quantity than energy. It gives
620 a result which is highly independant of the source spectrum
621 and shows lower bias than all other options.
622
623 - general: Dataset files are allowed to contain collections of
624 datasets. For more details see the class reference of MDataSet.
625
626 - general: The default WobbleMode in a datset file now (if not
627 overwritten) is "auto", i.e. wobble mode is set if the dataset
628 doesn't contain off-sequences.
629
630 - merpp: Merpp can read file format version 9 now. Please realize
631 that for file format version 9 the extraction range is different
632 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
633 the first and last 15 slices have been removed from all MUX data.
634
635 - mars: Similar to writing movies you can now select events which
636 should be displayed in your display. Therefore add the following
637 lines to your mars.rc:
638 MFEvtNumber.FileName: ganymed00223552.root
639 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
640 The input file can be a ganymed-file after (ganymed*.root) or
641 before (ganymed*-summary.root) file. For example to select all events
642 from your on sample after cuts (excluding the ThetaSq cut) use
643 MFEvtNumber.Selector: DataType.fVal>0.5
644 To show all events from your on-sample after quality cuts
645 use the summary file instead.
646
647 - mars: new ways to call mars are implemented. Instead
648 of calling
649 mars filename.root
650 you can now also use
651 mars sequence.txt
652 or
653 mars sequence.txt inputpath
654 or replace sequence.txt by the sequence number if the default
655 sequence file should be used.
656
657 - mars: The default size has been increased
658
659 - mars: There are two new heckboxes which allow to switch off
660 the calculated image parameters
661
662 - callisto: was broken for MCs... fixed.
663
664 - callisto: improved calculation of spline coefficients a lot. This
665 leads to a further improvement of the event rate calibrating MUX
666 data of about 15% (175evt/s instead of 150evt/s)
667
668 - callisto: finally the raw data we read is now real 16bit (with
669 10bit precision) for MUX data and not a stripped 8bit number
670 anymore. Due to scaling of the numbers (without precision loss
671 into an [0-256[ range, the final numbers for pedestal, pedestalrms
672 and extacted signal don't change. However, at all places where
673 raw data is directly accessed (eg. saturation and variation
674 limits in the signal- and pedestal-extraction) the numbers
675 refer still to the data's 16bit range.
676
677 - callisto: The maximum arrival time difference used in the bad
678 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
679 for both, old FADC and MUX-FADC, data.
680
681 - callisto: Be aware that callisto is now calibrating the arrival time
682 in nanoseconds rather than time slices. Also all following tasks
683 have been changed to assume ns units now. If you star data
684 calibrated with an older version it might be necessary to adapt
685 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
686 to obtain optimal results. The plot in the PulsePos tab
687 will now be in ns, too. This might also mean that the Muon
688 analysis in star might not work as perfect as expected as long
689 as old files read in.
690
691 - callisto: The calibration constants of earlier updates got lost
692 somehow. All constants have been updated.
693
694 - star: The PSF is now determined from the profile of the ArcWidth
695 instead of arcwidth/radius. The old way gave to much weight
696 to the bins with low statistics. The reference lines have been
697 updated.
698
699 - star: For speed reasons events suitable for the muon analysis
700 are now also preselected by fConcCOG<0.1 which seems to be a very
701 good preselector for muons.
702
703 - star: is now calculating a new timing parameter the Slope along
704 the major and minor axis of the shower. Therefore a numerical
705 solution of a line-fit is used. To use MHillasExt.fSlopeLong
706 and MHillasExt.fSlopeTrans don't forget to multiply it with
707 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
708
709 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
710 have been removed from MNewImagePar. They have never been good for
711 anything.
712
713 - star: Implemented a new recursive algorithm which is supposed to be
714 faster. Also implemented new cleaning oiptions, which are:
715 + CleanLevel0:
716 The cleaning level above single core pixels can be kept
717 + KeepIsolatedPixels:
718 Define whether single core pixels should be kept
719 + TimeLevel1:
720 The coincidence window in nanoseconds to single used neighbors
721 + TimeLevel2:
722 The coincidence window in nanoseconds to two used neighbors
723 + PostCleanType:
724 MOde in which a time dependent post cleaning should be applied
725 0: No post cleaning
726 1: Require for each used pixels at least one used neighbor
727 within a time-window of CleanLevel1
728 2: Require for each used pixels at least two used neighbor
729 within a time-window of CleanLevel2
730 3: Require first two and second one used neighbor
731 within a time-window of CleanLevel1 and fCleanLevel2
732 respectively
733 + RecoverIsolatedPixels:
734 - recoveres isolated core pixels if they have a used neighbor
735
736 - mars/star: The new default cleaning is:
737 + CleanLevel1: 6.0
738 + CleanLevel2: 3.0
739 + CleanTime1: 1.75
740 + CleanTime2: 1.75
741 + PostCleanType: 3
742
743 - star/ganymed: The old spark-cuts have been replaced by new ones.
744 These new spark cuts have been cross checked with the sequences
745 84720 (before splitter), 101041 (after splitter) and 223539 (new
746 FADCs). In all cases they seperate pretty well, but of course not
747 perfect. Monte Carlos have suggested to tighten the cuts a little
748 bit further at low sizes. This has been done.
749
750 - ganymed: IMPORTANT - The spark cuts have been changed to match
751 all available data more or less well. This might mean that for
752 YOUR data there are still sparks visible.
753 Whenever you do an analysis you have to make sure that NO sparks
754 survive your cuts!
755
756 - ganymed: The old hadronness and size cuts have gotten new indices
757 (10, 11). The old indices 8 and 9 now mean an additional condition
758 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
759 If you want to switch off this cut just move the line far away enough,
760 e.g. by setting c[9] to -500. Please update your ganymed.rc files
761 accordingly!
762 The unit of c[9] is deg. It is the dist at which your cut will
763 cross the slope==0. The unit of the slope is ns/deg. So if
764 you readin files calibrated with an older Mars-version you
765 have to adapt the default value for c[9] to the FADCs:
766 - Multiply by two for the MUX FADCs (run number > 200.000)
767 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
768 - Multiply by 42 for the meaning of life (run number = 200.000)
769
770 - ganymed: The old Cut0 is now called CutQ and is calculated before
771 the source position is caluclated. If you need a quality cut
772 including source dependant data (be very carefull with this!)
773 you have to use Cut0 instead.
774
775 - ganymed: now properly supports three off regions in wobble mode.
776 It will be the default from now on in ganymed_wobble.rc. To change
777 the number of off-regions use
778 NumOffSourcePositions: 1
779 in your ganymed.rc. Also by default no off-theta cut will be done
780 anymore so that you will get a background level higher than the
781 signal level in your ThetaSq plot for ThetaSq>0.2.
782 Due to this be carefull changing the scaling mode away from
783 "None". You will underestimate your signal if your scale interval
784 is not properly set.
785 (Rem: ThetaSqN is no longer needed)
786
787 - ganymed: is now storing the events of all (on- and off-)
788 source positions even in the case of more than one off-source
789 position. This should allow sponde to work properly and the
790 energy estimation is done correctly in all cases (without any
791 "nearest position" trick)
792
793 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
794 with a real pointing model for the starguider is done, calibrated
795 with more than thousand tpoints taken from this date on.
796
797 - ganymed: was broken for Wobble-MCs... fixed.
798
799 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
800 has changed. Note that your old ganymed.rc will be incompatible
801 with the new algorithms! Please check the ganymed.rc files and
802 the class description of MFMagicCuts for more information.
803 It is recommended at the moment to use identical Disp-Parametrizations
804 for on/off- and wobble-mode. If cuts are optimized only
805 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
806 should be optimized. All other values should be kept as they are.
807 If you want to do an anylsis without timing a parameters, you can
808 switch off the timing cuts by seeting parameter 7 to a very small
809 value (eg. -99). To remove the slope parameter from the disp
810 paremtrization set parameter 8 to 0.
811
812 - ganymed: The distribution of observation time versus zenith
813 angle is now shown for off- AND on-data.
814
815 - ganymed: The contents of the source position plot are no longer
816 averaged, thus a lot of (fake) events between the two wobble
817 positions have disappeared.
818
819 - ganymed: There is a new tab "CutT" it contains the VsSize plots
820 with the CutT, whihc is defined in ganymed.rc, applied. It
821 is resonable to use your theta-cut for it, to see if there is
822 something strange (sparks!) in your signal-region.
823
824 - ganymed: To choose a dataset from a collection in a dataset file
825 use the new command line option "--dataset=12345"
826
827 - optim, sponde: should now properly support three off-regions.
828 Just produce your ganymed summary files with three off-regions.
829 optim and sponde will automatically get all off events from
830 all off-regions from this file. Please do not forget to
831 set the scaling in optimwobble.C properly:
832 fit.SetScaleUser(1./3);
833 it is not yet read in automatically (will follow soon).
834 In the case of fixed Scale you can also use
835 cuts.SetThetaCut(MFMagicCuts::kOn);
836 no off-cut needed.
837 Be carefull in case of three off-regions when switching on
838 scale mode. Make sure that the scale interval is set correctly.
839
840 - sponde: sponde.rc and sponde_onoff.rc are now idetical
841
842 - sponde: the resouce files have been rewritten with a lot of
843 comments and a well working parametrization for an energy estimator
844
845 - sponde: In the estimated energy versus monte carlo energy plot the
846 contents where exchanged.... fixed.
847
848 - sponde: the so called "accurate"-mode has been removed. It didn't
849 give any improvement in accuracy, only decreased execution speed.
850
851 - sponde: the so called "simple"-mode has been removed. It didn't
852 give any improvement in simple.
853
854 - sponde: the so called "refill"-mode has been removed. It was anyhow
855 not implemented.
856
857 - sponde: now checks whether the theta distribution of your on-data
858 and the theta-distribution of your Monte Carlo sample (after
859 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
860 sample is incomplete) execution is stopped. Execution can be forced
861 using the new option --force-theta. Use this option with care!
862
863 - sponde: Proper collection areas can now be constructed also from
864 Monte Carlo samples generated with different maximum impact
865 parameters. Note that in previous version you neither got
866 a warning or failure, nor was there any obvious sign that the
867 collection area was overestimated due to usage of files with
868 different maximum impact parameters.
869
870 - sponde: If MC files with different lower energy limits are used
871 the primary MC spectrum is artificially completed down to the
872 lowest energy used at all. WARNING: that this gives correct
873 collection areas ONLY if none of the events in this region would
874 survive your cuts at all.
875
876 - sponde: the output file now contains more information about
877 the spectrum (eg. the full 2D collection area histogram).
878 Note, that this information can only be written to the file
879 if it is stored automatically via command line argument.
880 If you only store the status display from within the display
881 the information is lost.
882
883 - sponde: added a new tab "Disp". It shows the residual of the disp
884 (Disp-Dist) versus several parameters and it is meant to judge the
885 quality of the disp estimator. In the ideal case the residual is zero
886 and doesn't depend on any variable. The tab is displayed after
887 CutQ and Cut0.
888
889 - sponde: added a new tab "Energy". It shows the residual of the
890 energy (lg(estimated energy)-lg(monte carlo energy)) versus
891 several parameters and it is meant to judge the quality of the
892 energy estimator. In the ideal case the residual is zero
893 and doesn't depend on any variable. In reality even a good estimator
894 can show residuals versus Monte Carlo energy. The tab is displayed
895 after all cuts.
896
897 - sponde: added a new tab "EventDist" showing the unweighted real
898 absolute number of events of your sample after cuts. This tells
899 you how many events with this energy you had in your MC files.
900 The same information you get from the error bars of the weighted
901 histograms, but this is less intuitive.
902
903 - sponde: The spectrum plots now show the crab- and 1553-spectrum
904 for comparison. It is not meant to show these curves in
905 publications, they are only for production.
906
907 - sponde: The OriginalMC tree with the events produced by corsika
908 is now processed only once
909
910 - sponde: Finally fixed most annoying bug, which has effected the
911 last bin of the collection area. It was the problem that binnings
912 of root histograms are from 1 to n (included) but there was a C-like
913 loop in sponde from 0 to n (excluded). Now the loop also includes
914 correctly under- and overflow-bins. The worse thing with this is,
915 that for the events in the highest bin not only the bin-content
916 was wrong, but also the weights applied to these events, which could
917 in pricipal effect also other parts of the distribution (eg. due
918 to energy estimation). Fortunately it effected only a few events
919 in most cases.
920
921
922
923 *** Version 1.2 (2007/05/14)
924
925 - database: The database now has two new values Unsuitable50 and
926 Unsuitable01. They express the number of pixels which are
927 unsuitable for more than 50%, respectively more than 1%, of
928 all calibrated event. It is a more accurate number than the
929 previously used numbers, because they only take the first
930 calibration (ignoring the interleaved calibrations) into account.
931
932 - database: The database now has two other new values UnsuitableMax and
933 DeadMax. They express the maximum number of pixels which were
934 unsuitable, respectively dead, during the sequence. Because
935 of high pedestal rms (cars passing) a few events with very high
936 numbers of unsuitable pixels can happen. Not to suffer from this
937 effect we don't take the highest 0.1% of the numbers into account.
938
939 - general: fixed a bug which caused callisto and star to stop working
940 properly because the callisto output was currupted
941
942 - general: a script called scripts/makemovie has been added which
943 simplified the process of producing several movies from a single
944 sequence with different setup.
945
946 - callisto: Some more code cleanup. Started to remove old obsolete
947 code from cvs.
948
949 - callisto: The extraction of the pedestal with the extractor was
950 not random. It seems that extracting at one position is still biased
951 (for example in the first or last slices we could still suffer from
952 switching noise) Now it is completely random.
953
954 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
955 pedestal files) individual pixels could be skipped due to high
956 variations. This was already the case for the pedestal extraction
957 from the lo-gains since the beginning and properly handled
958 there, but was introduced in the extraction from the pedestal files
959 a while ago. To calculate the average value it was still divided
960 by the number of events procesed not by the number of summands
961 really summed. This let to a pedestal which was a tiny amount too
962 small (for a few piels in the order of 0.1%). This led to an slightly
963 positive offset of the randomly extracted pedestal for a few pixels.
964 I doubt that this has a big effect on the result, because the effect
965 on the individual numbers is quite small. Due to this it is suggested
966 that you rerun your calibration to make sure you are without any
967 avoidable bias.
968
969 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
970 the median rms of the absolute arrival time and expressed in significance
971 levels. This replaces the old meaning of an abolute upper limit. An
972 absolute upper limit doesn't make much sense, because in our data
973 all arrival times are shifted at the same time (in fact it might be
974 a shift of the artificial trigger w.r.t. to the light flash).
975
976 - callisto: Added a new tab "BadPixTm" which shows the time evolution
977 of the number of unsuitable pixels over the whole sequence. This
978 is usefull mainly to judge if an intermediate calibration had
979 problems.
980
981 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
982 of the number of dead pixels over the whole sequence. Dead pixels
983 in this context are unmapped pixels, i.e. pixels which could not
984 be interpolated, and thus are ignored in the further analysis.
985
986 - callisto: It is now possible to use the position of the maximum
987 of the spline as arrival time instead of the leading edge even
988 when using the integral for the signal. Therefor set the extraction
989 type to kIntegralRel ("IntegralRelative") and the relative height
990 ("HeightTm") to -1:
991 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
992 MJPedestalC1.ExtractSignal.HeightTm: -1
993
994
995
996
997 *** Version 1.1 (2007/04/27)
998
999 - general: The new class MGeomCamDwarf contains the camera geometry
1000 for our prefered Dwarf camera and can be used to create general
1001 geometries of roundish or hexagonal cameras.
1002
1003 - mars: The default cleaning is now abolute 8.5/4.0.
1004
1005 - mars: The resource file mars.rc now contains examples for MUX data
1006
1007 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1008 data containing only 10-bit information is still cooked down to
1009 8-bit, by cutting away the lowest 8-bit.
1010
1011 - merpp: When reading raw data the data is now stored in a single
1012 array. The lo-gain array is obsolete. The interface stays the same.
1013
1014 - callisto: To process the new MUX data use the resource file
1015 callisto_mux.rc
1016
1017 - callisto: The -root and -raw options to read merpped raw data have
1018 been removed
1019
1020 - callisto: If the -mc option is given the sequence-name can now be
1021 replaced by the MC sequence number
1022
1023 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1024 -mc option can now be omitted
1025
1026 - callisto: Started further simplification by removing obsolete
1027 dependancies on MCalibIntensity*Cams.
1028
1029 - callisto: removed unsused intensity calibration from MJCalibration
1030 for further simplification
1031
1032 - callisto: for simplification removed references to
1033 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1034 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1035 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1036 (this should at minimum change nothing at all, and at maximum
1037 improve thing if these containers where somewhere not handled
1038 properly)
1039
1040 - callisto: Added the option to write an event movie. Please use
1041 this option with care (huge files) but exessively to understand
1042 our events. For further documentation please refer to the
1043 IACT wiki
1044 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1045
1046 - callisto: Improved binning for the pulse position check histogram
1047
1048 - callisto: The code calculating the pulse position checknow takes
1049 the pedestal into account
1050
1051 - callisto: The arrival time is now stored with full precision this
1052 helps to get rid of artefacts in histograms. For the signal this
1053 is not necessray because it is displayed in log-scale anyhow
1054
1055 - callisto: Fixed a problem with internal exclusions. Pixels which
1056 have once been marked as unsuitable didn't get the necessary
1057 histograms filled anymore to be rechecked with each interleaved
1058 calibration.
1059
1060 - callisto: The relative arrival time resolution (the rms of the
1061 relative arrival time offset) is now checked against its
1062 median and the median deviation, instead of the average
1063 plus an absolute offset.
1064
1065 - callisto: The relative arrival time offset is now calculated
1066 w.r.t. its median not w.r.t. to an artificial reference pixel.
1067
1068 - callisto: The relative time calibration now marks pixels with
1069 outlaying offset as unsuitable
1070
1071 - callisto: The interleaved relative time calibration has been switched
1072 on. The advantage is that pixels which are marked as outliers
1073 now can recover. An improvement over time is not expected, because
1074 the relative time calibration seems stable.
1075
1076 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1077 option can now be omitted.
1078
1079 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1080 or the option "-mc" is specified as default the monte carlo datacenter
1081 paths (/magic/montecarlo/...) are used if not overwritten in the
1082 dataset file.
1083
1084 - ganymed: The output files now contain run- and event-number for all
1085 events, accessible as RunNumber.fVal and EvtNumber.fVal
1086
1087 - ganymed: Added a plot showing the source position in the camera also
1088 for wobble mode
1089
1090 - ganymed: In addition to the existing task which can be setup to
1091 be executed after Cut1 a final task called "EstimateEnergy"
1092 has been added, executed before writing the final output
1093 (ganymed00000000.root). The task setup in all three cases
1094 can be choosen individually. (For all three(!) cases you
1095 can for example choose MRanForestCalc. For examples see all
1096 sponde*.rc and all ganymed*rc)
1097
1098 - ganymed: If a container "MEstimatedEnergy" is found in the
1099 parameter list (eg. because it was setup by MEstimateEnergy)
1100 it will be written to the output file.
1101
1102
1103
1104 *** Version 1.0 (2007/02/16)
1105
1106 - database: Website to plot values from the database has been added.
1107
1108 - database: The rate of spark events as found by star is now kept
1109 and the rate after cleaning is now with spark events subtracted
1110
1111 - general: The changes to the interpretation of phrases lead to
1112 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1113
1114 - general: Added example files how you can create your own calendar
1115 (eg. as christmas present) with Mars. Just run
1116 root macros/tutorials/calendar.C
1117
1118 - general: Added a possibility to display grouped data in the plotdb.C
1119 macro (and similar macros). This allows to plot hourly, nightly,
1120 weekly, monthly and yearly averages.
1121 For more details see the plotall function of the macro
1122
1123 - general: fixed the error display of the camera display. It showed
1124 wrong results.
1125
1126 - general: fixed a memory leak when reading many MStatusDisplays
1127
1128 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1129 between a spherical and a parabolic mirror
1130
1131 - callisto: We have a new pulse position check which takes the properties
1132 of the extractor automatically into account. So no need to set
1133 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1134 left is done. If possible the lo-gain extraction start and hi-gain
1135 extraction end is changed accordingly. If no proper extraction range
1136 can be set (hi-gain too much to the left) an error is raised.
1137
1138 - callisto: New swapped pixels have been found and corrected
1139
1140 - callisto: Redone the signal extraction this includes:
1141 + Unified the algorithms to extract the pedestal for all pedestal
1142 extractions done
1143 + Unification of hi- and lo-gain into one array
1144 + Unification of hi- and lo-gain extraction for Spline and
1145 Digital Filter (means now exactly the same algorithm is used,
1146 not a copy-and-pasted one)
1147 + Store pedestal subtracted data in a common place
1148 + Improved extraction algorithms. If the algorithms search a
1149 maximum but don't find one they don't return the maximum anymore
1150 + Improved the extraction such that a information for signal
1151 and time which is consistent is returned
1152 + replaced the numerical spline with a (not slower) analytical
1153 solution
1154 + Lowered the saturation limit from 250 to 245 to make sure that
1155 we are far away in all pixels from problems with the clock-noise
1156 + The start of the lo-gain extraction is calculated from the hi-gain
1157 arrival time. In case of saturation an estimation is used.
1158 + the hi-gain window was extended to slice 16. This allows extraction
1159 of very late pulses in single pixels or of huge hadron showers.
1160 + Now uses the lo-gain extraction range for pedestal extraction,
1161 not the hi-gain range in the lo-gain
1162
1163 - callisto: New hi-/lo-gain calibration constants have been produced
1164 for all periods from the statistic of the whole period. They are
1165 now used automatically depending on the periods. The old constants
1166 where deviation in avarega about 2%-3%. The constants are very
1167 stable from period to period (<<1%) except for exchanged channels.
1168 In a few cases the constants used so far were off by 1%-2% (maybe
1169 temperature effects?)
1170
1171 - callisto: To gain obsolete space we do not write the
1172 MPedestalFundamental anymore. Also calibration and bad pixel
1173 treatment is not done for it anymore because it has never been used.
1174
1175 - callisto: Fixed a bug in the seuqence handling which caused the
1176 light condition to be ignored
1177
1178 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1179 basically the same as "Cleaned" but the distribution devided into
1180 the events fullfilling a spark cut or being rejected by it.
1181 This cut can be changed from star.rc (see example inside) by
1182 the "SparkCut" directive
1183
1184 - star: Star displays now the average individual pixel-rate (IPR) versus
1185 time and the average discriminator threshold (DT) of all pixels.
1186
1187 - optim: fixed a problem with the optim-macros which was due to a bug
1188 in the new phrase parsing
1189
1190 - ganymed: To get a nice FalseSource plot (instead of the all-information
1191 debug plot displayed as a standard plot) use the context menu
1192 somewhere between the two upper plots, click on "DrawNicePlot"
1193 and enjoy the result. (It is the same context menu which contains
1194 the other options)
1195 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1196
1197 - ganymed/optim/train: The cut program, trainings- and optimization
1198 macros could run with less files found than expected from the
1199 sequence-files. No the execution is stopped in this case.
1200
1201 - ganymed: now stores the dataset in the output file with all information
1202 contained (as sequence number, sequence path, data path) so that the
1203 used dataset file can be recreated complete from the output
1204
1205 - sponde: now also allows the uasge of random forest
1206
1207 - sponde: added a plot showing the cut efficiency
1208
1209 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1210 errors (eg. effecting the collection area) because the errors of the
1211 two histograms were swapped in the calculation, which makes a difference
1212 in the case the histograms contains weighted events. Aditionally the
1213 totalarea was incorrectly taken into account, which results in too small
1214 errors, which makes a difference at low statistics were the errors
1215 or the collection area dominate.
1216
1217
1218
1219 *** Version 0.10.3 (2006/10/23)
1220
1221 - database: Implemented ObservationMode flag in websites.
1222
1223 - database: For sequences there is now also the stoptime available on the
1224 websites.
1225
1226 - database: Removed ManuallyChanged flag from sequence-info websites,
1227 as it is not needed anymore with the new sequence building algorithm.
1228
1229 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1230 Class for calculation of confidence intervals (upper limits).
1231 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1232 Please read the class instruction of TRolke for more information.
1233
1234 - general: The programs now return 0xfe if the requested resource file
1235 doesn't exist.
1236
1237 - general: Errors comming from root itself are now not output to
1238 stderr anymore but to our default (colored) log-stream.
1239
1240 - general: Changed the interface to TFormula such that now everything
1241 is parsed by TFormula, which should allow to use phrases even
1242 without paranthesis correctly parsed.
1243
1244 - callisto: replaced the AdHoc number of effective integration slices
1245 in the digital filter by an average of the correct number, averaged
1246 over all possible set of weights. This also gives correct numbers
1247 for the lo-gains which were totally wrong before.
1248
1249 - callisto: drastically reduced memory consumption by not storing
1250 all intermediate calibration results in memory anymore (we might
1251 write them into a file in the future)
1252
1253 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1254 debug plot displayed as a standard plot) use the context menu
1255 somewhere between the two upper plots, click on "DrawNicePlot"
1256 and enjoy the result. (It is the same context menu which contains
1257 the "DrawAll" option)
1258 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1259
1260
1261
1262 *** Version 0.10.2 (2006/10/15)
1263
1264 - general: changed the building of the sequence files such, that
1265 the source-/project name in case of wobble-sources is not the
1266 source/project of the first data run anymore but the new generalized
1267 wobble source/project
1268
1269 - general: Added some functions to MAstro to calculate sun and
1270 moon properties
1271
1272 - general: Added two new macros (starvisday.C and starvisyear.C)
1273 which allow to plot the visibility of several stars in one day
1274 or of one star along one year
1275
1276
1277
1278 *** Version 0.10.1 (2006/10/11)
1279
1280 - general: HTML logging output was distorted... fixed.
1281
1282 - general: Changed the writing of the sequencefiles such that only
1283 as many pedestal files as giving at least 1000 pedestal events which
1284 are nearby the first calibration run are used as pedestal runs
1285
1286 - sponde: In the calculation of the collection area(s) and the
1287 distribution for MOnte Carlo and estimated energy the error
1288 calculation was wrong because root didn't take the errors
1289 properly into account... fixed.
1290
1291
1292
1293 *** Version 0.10 (2006/10/10)
1294
1295 - general: all executables now check consistency of the root version
1296 installed with the root version used for compilation. The return
1297 code in this case is 255.
1298
1299 - general: The algorithm to build seqeunces has been redesigned
1300 completly. It is now more flexible in terms of a resource file
1301 resources/sequences.rc which can be used to partly overwrite
1302 the default algorithm and defined the important part of the
1303 algorithm. It also takes correctly into account several ways
1304 of taking wobble-data. Currently the new algorithm doesn't take
1305 the number of pedestal events anymore into account (so a sequence
1306 could have much less than 1000 pedestal events and data runs are
1307 no-more used instead)
1308
1309 - general: a lot of small changes to make the code compatible with
1310 root 5.12/00 and gcc 4.1
1311
1312 - general: Fixed some warnings thrown if more warnings are switched
1313 on in the compiler
1314
1315 - general: Added a function to MMath which returns the Median of
1316 the distribution abs(y[i]-median) but at 68:32 division instead
1317 of 50:50, which is somehow the median counterpart of the rms.
1318
1319 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1320 even if they are compressed with gzip (recommended compression
1321 is with "-1")
1322
1323 - showplot:
1324 + batch mode creation of image files now works with root 5.12/00
1325 + added support for writing bmp (though it never produces
1326 bmp which can be read by programs like xv or gimp)
1327 + added support for xml
1328 + added new option to start the display with a different size, by
1329 --display-width=nnn or --display-height=nnn
1330 + added options to define the canvas size when the display is started
1331 --canvas-width=nnn or --canvas-height=nnn
1332 the option can also be used for batch-mode conversion
1333 + added an option which automatically fits the display size to the
1334 desktop-size: --auto-size
1335
1336 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1337
1338 - merpp: allow the reports to have 1000ms due to a bug in the camera
1339 program.
1340
1341 - callisto: New swapped pixels have been found and corrected. For
1342 details see MRawRunHeader::FixAssignment()
1343
1344 - callisto: Callisto now raises an error if one of the input files could
1345 not be opened.
1346
1347 - callisto: In some rare cases it could happen that in the signal
1348 extraction of the digital filter the extractor returned nonsense
1349 results due a wrong initializion of a variable (this happens in
1350 cases in which the extracted signal is exactly zero or the
1351 digital filter couldn't slide because of a too small extraction
1352 window, which could happen in the lo-gain extraction)
1353
1354 - callisto: The lo-gains have been marked as valid in some cases
1355 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1356 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1357 smaller than the number of slices (fLoGainWindowSize) needed
1358 by the lo-gain extractor
1359
1360 - callisto: Updated absolute calibration constants (muon calibration)
1361
1362 - callisto: fixed a bug which caused the hi-gain saturation not
1363 to be handled properly in the spline (the position of the
1364 saturation was calculated incorrectly)
1365
1366 - callisto: fixed a bug which gave weird results if hi- _and_
1367 lo-gain could not be extracted properly. In some cases hi-
1368 and lo-gain have not been extracted at all and the random result
1369 got calibrated. In other cases the hi-gain was saturating and the
1370 lo-gain has not been extracted. For this a completly arbitraty
1371 scale factor was applied to the result from extracting the
1372 charge of the saturating hi-gain.
1373
1374 - callisto: improves handling of extracted signal if lo- and/or
1375 hi-gain could not be extracted properly. If no appropriate
1376 calibration of either the signal or the arrival time is possible
1377 the pixel is now markes as unsuitable instead of estimated.
1378
1379 - callisto: Fixed a problem in the spline extraction which gave
1380 weird results if the signal was extracted from the first (and
1381 highest) slice (as a workaround extraction from the first
1382 slice has been forbidden)
1383
1384 - callisto: Fixed a bug regarding the use of the QE which doesn't
1385 effect the result because the default is used anyhow.
1386 (The bug was there since 14/07/2005)
1387
1388 - callisto: Changed the default for fgLoGainStartShift to -2.4
1389
1390 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1391 factors to be always 10 for all pixels as soon as the first
1392 calibration update has happend.
1393
1394 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1395 was off by more than one slice (which gives wrong values for
1396 pixels which have saturated the hi-gain) This was a problem
1397 mainly for timing studies, not so much for the automatic standard
1398 analysis. Also the values for the Spline have been changed slightly:
1399 + Digital Filter from 1.70 to 0.95
1400 + Spline from 1.39 to 1.30
1401 The numbers were sorted out by an extensive test in the
1402 test-database.
1403
1404 - callisto: Removed the tab showing the average calibrated arrival
1405 time. It never gave useful information.
1406
1407 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1408 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1409 and both were extracted because the hi-gain was above the
1410 LoGainSwitch.
1411
1412 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1413 lo-gain pulse position (after application of LoGainOffset, which
1414 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1415 have saturated and both were extracted because the hi-gain was above
1416 the LoGainSwitch.
1417
1418 - callisto: After extensive tests a new threshold level for determination
1419 of the pulse position has been found at 50phe. This is due to the
1420 fact that for lower pulses the arrival time changes its average
1421 behaviour dramatically. It tends to the average of the extraction
1422 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1423
1424 - callisto: Added two more plots to the calibration part. The average
1425 extracted signal and the average extracted arrival time as
1426 extracted by the signal extractor (This can help debugging problems
1427 because it doesn't involve a fit)
1428
1429 - star: changed the fit for the effective on time such that initial
1430 values are calculated automatically now instead of using build
1431 in values. This makes the fit more indepedant of the underlaying
1432 rates. With a test of ~350 sequences in the test database it could
1433 be shown that the new fit gives the same result +/-1sek.
1434 The highest deviation was +5s the lowest -10s. You can now control
1435 the bahaviour with two resource values:
1436 MHEffectiveOnTime.FistBin: 3
1437 MHEffectiveOnTime.NumEvents: 12000
1438 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1439 from the resulting gamma candidates
1440
1441 - star: The Center histogram in MHHillas is now by default displayed
1442 with the colz draw-option
1443
1444 - ganymed: now produces valid error codes if failed
1445
1446 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1447 with the option "hadronness" instead of "area" or "both" if
1448 you want to use both cuts. The hadronness cut includes a fixed
1449 cut in hadronness (index 8) and a fixed cut in size (index 9).
1450
1451 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1452 the M3Long of the anti source to be not properly evaluated
1453 (actually is was evaluated as a unique random number) in case
1454 of optimization with anti-theta cut switched on. This might have
1455 lead to improper, but not necessarily wrong, optimization results.
1456
1457 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1458 how to use random forest
1459
1460 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1461 ganymed_onoff.rc. Seems to be unintentional that they were different.
1462
1463 - sponde: Since the introduction of the possibility to define a
1464 normalization energy instead of using the integral the default
1465 was not using the integral anymore but a normalization energy of
1466 1GeV. It is now the integral again.
1467
1468 - sponde: Fixed a problem in the weighting which did not allow
1469 a MC slope of -1.
1470
1471
1472
1473 *** Version 0.9.6 (2006/05/24)
1474
1475 - general: changed the binning of the azimuthal profile of the camera
1476 such that it is aligned with the 60deg boundaries.
1477
1478 - merpp: better handling of problems with the TH, TD part of the
1479 CC-REPORT for files older than 200507190 and 200412210
1480 respectively
1481
1482 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1483
1484 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1485
1486 - callisto: if an arrival time is extracted outside the fadc range is
1487 was set to the boundary before. Now a random number is assigned
1488 instead to avoid unfortunate coincidences of arrival times just
1489 by this arbitrary value.
1490
1491 - callisto: added a new option to callisto.rc which allows
1492 to set the maximum arrival time difference allowed for the
1493 badpixel algorithm to determin whether a pixels belongs to a shower:
1494 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1495
1496 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1497 to 0.9 as suggested by Stefan due to a recent study on the fraction
1498 of pixels surviving the image cleaning
1499
1500 - callisto: switched off error in case of "pulse is too much to the left"
1501
1502 - callisto: The extraction window is not adapted anymore. This means that
1503 the pulse is extracted from the full range. The draw-back is that the
1504 background (pedestal) will become slightly higher. Switching on/off
1505 the PulsePosCheck in the callisto.rc only effects filling the
1506 histograms.
1507 WARNING: If the pulse is too much to the left data is calibrated!
1508 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1509 in the database to make sure that your data is valid!
1510
1511 - star: Show also the number of stars correlated correctly by the
1512 starguider
1513
1514 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1515 than one off-source region in wobble-mode. To use it add the following to
1516 your ganymed_wobble.rc:
1517 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1518 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1519 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1520 + Cut1.ThetaCut: None
1521 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1522
1523 - ganymed: in the case the latest report is older than a default (currently
1524 one minute) and the current report will be skip the starguider
1525 correction and calibration will be reset. The maximum age can be
1526 setup from ganymed.rc by (minutes):
1527 MPointingDevCalc.MaxAge: 1.5
1528
1529 - ganymed: A first implementation showing all size-bins for the theta-sq
1530 resp. alpha-plots in a single tab automatically
1531
1532
1533
1534 *** Version 0.9.5.1 (2006/05/05)
1535
1536 - general: Added a new option "zdiff" to the Makefile which runs
1537 "cvs diff" as "make diff" would do, but with compression
1538
1539 - general: accelerated MTFillMatrix (used for eample in all training
1540 and optimization macros) by skipping some obsolete calles in the
1541 eventloop the first and second loop could be accelerated by ~20%
1542
1543 - general: Added a missing feature in the MFilterList class which
1544 prevented MFEnergySlope from working correctly in trainenergy.C
1545
1546 - general: Accelerated the random forest training and usage a bit
1547
1548 - merpp: Adapted to new raw data file format version 6
1549
1550 - merpp: fixed a problem with reading the starguider reports
1551 after 6.3.2006
1552
1553 - callisto: At some times six pixels had to be exchanged manually in the
1554 data. If the pixels to be swaped are both not found, an error was raised
1555 and calibration was stopped. Now it is assumed they are intentially not
1556 mapped and the Error has been changed to a Warning.
1557
1558 - star: Added new image cleaning based on the arrival time of the shower.
1559 The new cleaning can be accessed using the parameter "Time" instead of
1560 the the old one (like "Absolute) in the star.rc-file.
1561 Recommended parameters:
1562 + MImgCleanStd.CleanLevel1: 8.2
1563 + MImgCleanStd.CleanLevel2: 5
1564 + MImgCleanStd.CleanRings: 2
1565 + MImgCleanStd.KeepSinglePixels: No
1566
1567 - star: Simplified the calculation of the effective on time. By letting
1568 the fit start in the third bin the result should become more stable.
1569 The fit quality is now ignored for the theta-plot which is not used
1570 in the analysis later. Still better pre-cut which, for example,
1571 remove events triggered by car-light (rate changing on a short
1572 time-scale) are missing.
1573
1574 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1575 for optimization (kWeakSource) which is suggested by the Berlin
1576 people for weak sources.
1577
1578 - macros: plotdb.C:
1579 + if no dataset and no time-interval is given only sequences with
1580 an effective on-time above five minutes are plotted anymore
1581 + added a new tab "RelTime" displaying the relative on-time
1582 (effective on-time divided by the observation time)
1583
1584 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1585 the optimization became a lot faster
1586
1587 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1588 To display them just delete the pads displayed on top.
1589
1590 - ganymed: fixed a bug which could cause strange behaviour in wobble
1591 mode if no starguider information was available due to an incorrect
1592 initialization of the starguider calibration
1593
1594 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1595 be changed from within the plot. It can also be setup from the
1596 resource file using:
1597 + MHDisp.fScaleMin: 0.325
1598 + MHDisp.fScaleMax: 0.475
1599
1600 - ganymed, showplot: Fixed a problem with the fit to the off-data
1601 (HistOff) which could cause a time lag or an inifinite loop.
1602 The bug did not effect the results at all.
1603
1604 - sponde: Added a new tab showing the effective collection area after
1605 trigger (including the software trigger)
1606
1607 - sponde: MMcSpectrumWeight has a new option which allows to define
1608 the scaling factor not by the integral of the events but at
1609 a defined energy:
1610 e.g. MMcSpectrumWeight.NormEnergy: 200
1611
1612 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1613 eventloops the loop could be accelerated by ~20%
1614
1615
1616
1617 *** Version 0.9.5 (2006/03/13)
1618
1619 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1620 and added the standard Disp-parametrization
1621
1622 - macros: added a new macro datacenter/macros/plotstat.C allowing
1623 to plot statistics about the data processing
1624
1625 - macros: added a new macro to plot the muon correction coefficients
1626 versus period (macros/plot/mucal.C)
1627
1628 - showplot: path inflation for ganymed files was broken
1629
1630 - callisto: Fixed an important bug. When the number of saturating pixels
1631 were calculated the bad pixel information already available from the
1632 calibration was ignored. This yields wrong values in case pixels
1633 are broken and saturate all the time or randomly.
1634
1635 - callisto: Updated Muon calibration constants. Spline data now also uses
1636 different values for different periods
1637
1638 - star: The time-evolution shown in the effective on-time plot now displays
1639 the axis range (if there are no holes it should be similar to the
1640 effective on-time)
1641
1642 - star: Added two new image parameters:
1643 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1644 the three pixels next to the center of gravity and the size
1645 + MNewImagePar.fConcCore: The ratio of the signals of all
1646 pixels inside or touching the ellipse and the size
1647
1648 - ganymed: now stops in requested source isn't found in catalog file
1649
1650 - ganymed: Many improvements to the phi-plot in wobble mode:
1651 + with a template the ideal background is displayed
1652 + a possible camera inhomogeneity is taken into account
1653 + the anti theta cut is better supported
1654 + the phi cut is automatically calculated from the theta cut
1655 See the examples in ganymed_wobble.rc for more details.
1656
1657 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1658 times the bin-width instead of the absolute energy
1659
1660 - ganymed: New cuts for on/off and wobble mode
1661
1662 - ganymed: The smearing of the False Source plot has been increased
1663 to 0.06
1664
1665 - ganymed: The starguider calibration can now be changed from the
1666 resource file.
1667 See the examples in ganymed*.rc for more details.
1668
1669 - ganymed: added a new option for on-/off-observations
1670 MJCut.RandomSourcePosition
1671 If switched on the distribution of observation time of the source
1672 position in the camera is calculated from the on-data and randomly
1673 applied with this distrbution to the off-data.
1674
1675 - ganymed: by skipping some obsolete calles in the eventloop the
1676 first and second loop could be accelerated by ~20%
1677
1678 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1679 position in the off-data randomly according to its distribution in the
1680 on-data.
1681
1682
1683
1684 *** Version 0.9.4.3 (2006/02/13)
1685
1686 - general: Fixed a bug in most of the programs which prevented the
1687 compile date in the startup message to be displayed
1688
1689 - general: Simplified program calls. The following abbreviations
1690 are now possible:
1691 showlog callisto 55599
1692 showplot signal 55599
1693 star 55599
1694 callisto 55999
1695 ganymed 2
1696 In this cases the corrsponding root-, log-, sequence- or dataset-
1697 filename is automatically compiled using the default datacenter
1698 paths ("/magic/*")
1699
1700 - general: Fixed a long outstanding bug which made axis tick marks
1701 disappear if MDataFormula was used (eg. abs(x))
1702
1703 - general: Updated MMath with new functions to calculate the results of
1704 a exponential, logarithmic and powerlaw fits analytically.
1705
1706 - general: Updated some macros with comments:
1707 + macros/optim/optimdisp.C
1708 + macros/optim/optimenergy.C
1709 + macros/optim/optimwobble.C:
1710
1711 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1712 files) now allows adding a pre-cut like in the optimization. E.g. this
1713 is useful to perform g/h-separation cuts before training the random
1714 forest.
1715
1716 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1717 correctly assigned in the raw data assignement table. A fix to correct
1718 the assignment tabel have been implemented.
1719
1720 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1721 by 90, 180 and 270 deg.
1722
1723 - general: the macro plotdb.C now allows to highlight sequences belonging
1724 to a datset. For more details see the descritions in the macro.
1725
1726 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1727 of the display, it gave wrong results espacially for big sizes.
1728 Now the embedded canvas should always have a ratio width/height=3/2.
1729 The "Size" options have been updated with values fitting the 3/2
1730 size ratio.
1731
1732 - RanForest:
1733 + Updated the random forest classes to support also the
1734 regression method implemented by Thomas H.
1735 + added new tutorial macro how to train the random forest
1736 for energy estimation (macros/optim/rfenergyest.C)
1737 + new classes to train the random forest (still in development)
1738 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1739 + new tutorial macros for random forest training in macros/train
1740 trainenergy.C, traindisp.C, trainseparation.C
1741
1742 - mars: now allows to setup a cut in the resource file mars.rc to choose
1743 the events to be displayed, eg:
1744 Cut.Condition: {0} && {1}
1745 Cut.0: MHillas.fSize>100
1746 Cut.1: MHillas.fSize<900
1747
1748 - merpp: Made aware of the new .rep format 200510250. This includes
1749 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1750 the discriminator thresholds (MCameraTD) and the disciminator
1751 delays (MCameraTD). All of them come with the CC report and are therefor
1752 written to the CC tree.
1753
1754 - callisto: fixed a bug in the calculation of the arrival times in
1755 the Digital Filter. They were all shifted by the same amount
1756 fHiGainFirst. This caused an offset in the order of the position of
1757 the left border of the extraction window in the times calculated
1758 from high-gain and from low-gain. The bug effected only the absolute
1759 arrival times. The bug was there since 30.1.2005.
1760
1761 - callisto: Changed the ExtractionWindow for the pulse position check
1762 such that the camera inhomogeneity becomes as less as possible and
1763 comparable to the pulso position check switched off. More details
1764 on the study will be given at our result web-page.
1765
1766 - ganymed: ganymed.rc, ganymed_onoff.rc:
1767 changed to new cuts trained with 1ES1218 and Crab-data
1768 for maximum sigma*log10(excess)
1769
1770 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1771 a new option was implemented to estimate Disp (CalcDisp)
1772
1773 - ganymed: Implemented two new options which allow
1774 to overwrite the default path to search for the sequence files
1775 --ins=/magic/sequences
1776 and where to search for the image data
1777 --ind=/magic/data/star
1778
1779 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1780 dx/dy from the resource file by
1781 MSrcPosCorrect.Dx
1782 MSrcPosCorrect.Dy
1783
1784 - ganymed: fixed reading the source catalog. Only as many chars
1785 as the requested source name had were compared (If a source
1786 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1787 were requested it could happen that the coordinates of
1788 "1ES1218" were read) The source coordinates are now printed
1789 in addition to its name to the logging output.
1790
1791 - ganymed: changed the background fit in the case of a ThetaSq function
1792 from a polynomial to a exponential, this should give a big improvement
1793 for on-only analysis'
1794
1795 - ganymed/sponde: Calculation of the error of single size-/energy-
1796 bins now uses Li/Ma (5) instead of LiMa (17)
1797
1798 - sponde: Added a plot E^2*dN/dE
1799
1800 - sponde: The energy estimator plot should now show values like
1801 they are commonly used.
1802
1803 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1804 (a powerlaw with cutoff didn't work before)
1805
1806
1807
1808 *** Version 0.9.4.2 (2005/10/01)
1809
1810 - general: added new tutorial macro macros/tutorials/threshold.C:
1811 how to calculate the threshold
1812
1813 - general: added a new game. Start it from the interpreter with
1814 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1815 and MagicReversi)
1816
1817 - general: neighbor pixels in MGeoms are now sorted clockwise
1818
1819 - merpp: made aware of new format 20050829-0
1820
1821 - callisto: New scale factors from muon analysis, stored in new
1822 resource file resources/calibration.rc
1823
1824 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1825 the eventloop if something went wrong. This is necessary for the
1826 automatic processing
1827
1828 - callisto: Implemented a new treatment for the time information
1829 developed by S.Ruegamer, this should give much better response than
1830 the old very primitive algorithm. This is especially important
1831 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1832 treatment was buggy! As neighbor pixels to interpolate the
1833 arrival times always the pixels 0 to 5 were taken)
1834
1835 - callisto: In addition to the new treatment of arrival times the
1836 decision of the treatment whether a pixel contains shower
1837 information or not is used to improve the signal interpolation
1838 further. Previously interpolated pixels showed a non-zero signal
1839 do the peak searching signal extractors. Having a signal pixel
1840 beside raised the signal above the cleaning level. Thus the
1841 pixel survived cleaning to often but with a too low mean signal.
1842 By replacing empty pixels with a gaus (mean and rms from the
1843 corresponding Area entries in MPedPhotCam) this effect can
1844 be supressed.
1845
1846 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1847 got lost when the events were stored by the calibration... fixed.
1848 (This was no problem for normal image cleaning because the pixel
1849 content was artificially set to 0 not surviving standard cleaning
1850 algorithm)
1851
1852 - callisto: Fixed a bug which caused the random and peak-search pedestal
1853 extracted with an extractor to be exchanged for the first (roughly)
1854 500 events (*Extractor and *ExtractorRndm).
1855 (They were simply exchanged in callisto.cc) This bug might have been
1856 introduced in Mars 0.9.4 when the order of calculation of the two
1857 types of pedestal in callisto got exchanged. The bug only effects
1858 the first seconds of data of each sequence.
1859
1860 - star: Taking the arrival time of Muons into account the calculation
1861 of the parameters could be made independant of the noise
1862 (pedestal rms). The dependance was due to the bias of the peak search
1863 extractor. Now only a ZA dependamcy is left which is not yet fully
1864 understood.
1865
1866 - ganymed: The sequences were still not sorted correctly in any case,
1867 because they were sorted by the full qualified path name. Now they
1868 are sorted by their sequence number.
1869
1870 - ganymed: new values for the spark-event-cut
1871
1872 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1873
1874
1875
1876 *** Version 0.9.4.1 (2005/08/18)
1877
1878 - callisto: fixed some problems with the calibration in case of
1879 inteleaved events. Therefor the final and some intermediate
1880 fits are skipped which would take place on partly filled #
1881 histograms and gave wrong results or failed completely.
1882
1883 - callisto: If the intermediate finalization of the histograms
1884 calculating the mean charge of the calibration signal fails
1885 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1886
1887 - ganymed: Fixed some bugs which caused problems in On-only mode.
1888 Still the false source plot doesn't give reasonable results.
1889
1890
1891
1892 *** Version 0.9.4 (2005/08/05)
1893
1894 - general: Fixed the ZA binning. It did not correctly fit the
1895 MC binning
1896
1897 - general: Added a class to correct for the missfocussing in
1898 April (MSrcPosCorrect)
1899
1900 - general: Random Forest energy estimator should now work properly
1901
1902 - general: MHCamera now displays the profiles in deg instead of mm
1903
1904 - general: MH::SetPalette offers a lot of new palettes
1905
1906 - general: MHillas - the case of CorrXY==0 is now handled properly
1907
1908 - general: implemented the possibility to change the line and
1909 marker style of a sky-grid drawn by MAstroCatalog
1910
1911 - general: Runs in sequences and datasets are now automatically
1912 ordered (it is assumed that the order of their filenames correctly
1913 represents the order of observations) to ensure correct reading
1914 of the subsystem data
1915
1916 - general: Runs cannot be added to a sequence twice anymore. Also
1917 Sequences cannot be added twice anymore to a dataset.
1918
1919 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1920 It gave wrong results by 1./2pi
1921
1922 - showplot: got a new option to start a root interpreter, too
1923
1924 - mars: now displays a rough estimate of Disp and the third moment
1925
1926 - mars: now displays the event time MTime if available
1927
1928 - mars: show muon parameters graphically
1929
1930 - mars: now the file to open can be given as commandline
1931 argument
1932
1933 - merpp: Added support for new arehucas version >= 200507190
1934 implementing values for three temperature sensors in the
1935 counting house (MCameraAUX) and the name of the HV settings file
1936 (MCameraHV).
1937
1938 - merrp: Also fixed some problems with wrong versions numbers stated
1939 by arehucas and implemented some fixed for old versions (<200407070)
1940
1941 - callisto: MCalibrationHiLoCam can now be printed from its context
1942 menu, eg in the TBrowser
1943
1944 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1945 - 1.39 (MExtractTimeAndChargeSpline)
1946 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1947 This is important mainly for timing studies.
1948
1949 - callisto: Changed limits in MHCalibrationChargeCalc from
1950 - -100.125 to -98 (fgChargeHiGainFirst)
1951 - 1899.875 to 1902. (fgChargeHiGainLast)
1952 - -100.25 to -99 (fgChargeLoGainFirst)
1953 - 899.75 to 901. (fgChargeLoGainLast)
1954 Introduced new limits:
1955 - fgNumLoGainBlackoutLimit: 0.05
1956 - fgLoGainBlackoutLimit: 3.5
1957 - fgLoGainPickupLimit: 3.5
1958
1959 - callisto: The handling of automatic weights for the digital filter
1960 has been improved. There are now new calibration weights special
1961 for Monte Carlo calibrations.
1962
1963 - callisto: Updated Muon scale with latest results (1% difference
1964 for most data, 5% for Mar/Apr'05)
1965
1966 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1967 was saturated and the blackout-events in the low-gain exceed the
1968 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1969 This excludes those pixels which have a saturating high-gain
1970 channel, but the low-gain switch does not switch often enough
1971 to make the distribution reliable.
1972
1973 - callisto: fix a bug counting the number of saturated events. Up to now,
1974 the number of saturated slices was counted (which is one for a not too
1975 high number), but for some (pathological) pixels, many more slices
1976 saturated and produced wrong limits.
1977
1978 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
1979 + MCalibrationRelTimeCam.CheckFitResults: Yes
1980 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
1981 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
1982 + MCalibrationRelTimeCam.CheckOscillations: Yes
1983
1984 - callisto: introduce max. number of events for intercalibration,
1985 the rest gets skipped. Default: 4096
1986 The calibration causes too many un-reliable pixels if more
1987 than about 5000 events are treated (@500 Hz) because of the
1988 mode hopping of the VCSels. However, in the past, some
1989 calibration runs have been taken (erroneously) with more
1990 than 5000 events, especially the intensity scans where
1991 a good precision is needed.
1992
1993 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
1994 photo-electrons for the spline extractor by 1-2% (correctly).
1995
1996 - callisto: The intercalibration is now done using a full f-factor
1997 method instead of a simple update. This makes things slower but
1998 more reliable in terms of gain-fluctuations and sudden VCSEL gain
1999 changes.
2000
2001 - callisto: MPedestalY3 now uses the same extraction range as the data
2002 as calculated by MPedestalY2
2003
2004 - callisto: A check of the fraction of allowed unsuitable (10%) and
2005 unreliable (30%) pixels has been addded when the conversion is
2006 calculated from interleaved events
2007
2008 - star: fixed a bug which caused MEffectiveOnTime containers not to
2009 be written. In the worst case they were skipped almost all, in the
2010 best case they were all ok. It depends on how often the new value
2011 was assigned just with an event which was skipped later by another
2012 task
2013
2014 - star: new histograms MHPointing and MHRate
2015
2016 - star: New tab (Currents) displaying the time evolution of the mean
2017 DC currents
2018
2019 - star: New tab (MeanRms) displaying the time volution of the mean
2020 Pedestal Rms
2021
2022 - star: Output now contains MReportStarguider
2023
2024 - star: Improved muon analysis. Due to the absense of a constant
2025 for the gaus fit for arc width and the fact that the arcwidth
2026 plot was a histogram instead of a profile the resulting psf
2027 became pedestal rms dependant
2028
2029 - ganymed: added new plot (MHPhi) for wobble mode as described in
2030 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2031
2032 - ganymed: corrects now (correctly?) for the misspointing in
2033 May/April 05
2034
2035 - ganymed: Two new default templates for ganymed.rc are avilable:
2036 ganymed_onoff.rc and ganymed_wobble.rc
2037
2038 - ganymed: The first version of MFMagicCuts has been released
2039
2040 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2041
2042 - ganymed, sponde: There are two new options to determin the number
2043 of bins for the signal region (NumBinsSignal) and the number of
2044 total bins (NumBinsTotal) in the MHThetaSq histogram
2045
2046 - ganymed: optimized palettes for MHDisp
2047
2048 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2049 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2050 sqrt(2) to large
2051
2052 - ganymed: The false source plot (MHDisp) is now based on Disp
2053 and a background model determined in the first loop is
2054 subtracted
2055
2056 - ganymed: MFMagicCuts are now available in the cvs. The correct
2057 solution for the disp ambiguity problem is now calculated using
2058 the third moment. The third moment cut therefor is skipped.
2059
2060 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2061 already determined by the third moment along the major axis and
2062 so its actual sign is aligned along the major axis of the shower.
2063
2064 - ganymed: If starguider data is available it is taken into account
2065 when calculating the source position. This is especially important
2066 for wobble data at high zenith angles and culmination data.
2067
2068 - ganymed: If available the starguider data is taken into account as
2069 good as it is possible without a starguider calibration. To switch
2070 it off add
2071 MPointingDevCalc.MaxAbsDev: -1
2072 to your ganymed.rc
2073
2074 - sponde: the zenith angle distribution is now weighted instead of
2075 choosen by default. This gurantees higher statistics in the highest
2076 and lowest energy bins. To switch this behaviour off use...
2077
2078 - sponde: now automatically displays the energy threshold
2079
2080
2081
2082 *** Version 0.9.3 (2005/06/03)
2083
2084 - general: MMcEvt now derived from MMcEvtBasic which should
2085 have no influence on compatibility with older camera files
2086
2087 - general: Implemented a new option to MReadReports which allows
2088 to force reading of the first event of some trees (eg. Drive-tree)
2089 before any other tree.
2090
2091 - general: Made a fix to MPointingPosCalc which assumes that the
2092 run-type is real-data if Process is called before ReInit, such
2093 that also the very first Drive-events in a run are treated
2094 correctly.
2095
2096 - shoplot now displays the filename in the title bar of the window
2097
2098 - merpp: new options: --auto-time-start --auto-time-stop which
2099 allow to cut updating with slow-control at the start- or
2100 (previousle --auto-time only allowed: and) stop-time of
2101 the run stored in the runheader.
2102
2103 - callisto: changed default of fgFallTimeHiGain in
2104 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2105 already set as default in callisto_Dec04Jan05.rc
2106
2107 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2108 now changes the filename for new weights automatically for
2109 cosmics, MC and for different calibration colors.
2110
2111 - callisto: a problem with the order of some code cause the
2112 name of the weights file in MPedestalY2 to be ignored.
2113 Wrongly the calibration_UV weights were used instead
2114 of the cosmics weights set in callisto.rc.
2115
2116 - callisto: should allow ct1 pulser data when the color is
2117 explicitly set also for pretty new runs
2118
2119 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2120 to introduce an additional scale factor (should be around 1)
2121 to adapt for slight deviations in different extractors from
2122 the MC calibration. For MC calibrations the scale factor
2123 is fixed to 1
2124
2125 - callisto: MFCosmics should handle very high signals a bit
2126 more accurate now
2127
2128 - callisto: when calculating the mean pedestal rms for different
2129 pixel sizes or sectors also kUnsuitableEvt is now taken into
2130 account - not only kUnsuitableRun
2131
2132 - callisto: '-raw' option is now the default
2133
2134 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2135 This has the advantage that mean values in the calibration (eg
2136 arrival times) are calculated more accuratly.
2137
2138 - callisto: In the resource file callisto_Dec04Jan05.rc
2139 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2140
2141 - callisto: new Hi-/Lo-Gain intercalibration constants
2142 hilocalib_sp1.root and hilocalib_sp1_mc.root
2143
2144 - callisto: changed default for MJPedestalY2.MaxEvents
2145 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2146
2147 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2148 has changed from 9.0 to 6.0. This is necessary to exclude two very
2149 ringing pixels in September which - when kept - destroy the image
2150 cleaning around them (Markus G.)
2151
2152 - callisto: (!) The Muon analysis of all data taken so far has
2153 suggested that different extractors give slightly different
2154 absolute results after calibration, due to there different
2155 handling of the calibration- and cosmics pulse shape. Although
2156 the over all calibration seems to be a bit to pesimistic (or
2157 the MC seems to be a little bit - 3-5% - too much attenuated).
2158 There for correction factors have been introduced which correct
2159 the calibration constants by
2160 0.956937799 for Digital Filter (callisto.rc)
2161 and
2162 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2163 calibration. The main advantage is, that both data types can
2164 be easily analysed together and compared to the same MC sample.
2165 The factors are choosen such, that the reference is now a
2166 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2167
2168 - star: fixed a bug which caused the first bin of the histograms
2169 vs time to disapear in PostProcess. This gave wrong results
2170 on the screen. The output and all following programs not
2171 directly accessing the histograms haven't been affected
2172
2173 - star, ganymed: Made sure that always the first Drive-tree event
2174 is read and Processed before the first data event was read.
2175
2176 - ganymed: implemented the possibility to replace the standard
2177 false source plot with a different one. For example: If
2178 you want to use a Disp based FS plot use the resource:
2179 NameHistFS: MHDisp
2180 For details about the requirements of these plots look
2181 at the corresponding classes
2182
2183 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2184 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2185 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2186 case MAlphaFitter is setup correctly. For On-Only optimization
2187 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2188 RunOn() instead of Run(). For energy estimation MJOptimize
2189 has been replaced by MJOptimizeEnergy
2190
2191 - sponde: The input MC spectrum can now be weighted to fake a
2192 different spectrum. This is done via MMcSpectrumWeight. For
2193 more details see the class description and sponde.rc
2194
2195 - sponde: The paremeter comparsion plots are not scaled by
2196 their entries anymore. Instead the MC plot is scaled by using
2197 the result spectrum of the analysis. If the input MC spectrum
2198 and the result spectrum has different slopes the absolut
2199 normalization is normally wrong.
2200
2201
2202
2203 *** Version 0.9.2 (2005/05/20)
2204
2205 - general: Changed the default paths for calibrated data and image
2206 files. (The implemented access to these files doesn't yet exist)
2207
2208 - general: support for MRunIter has been removed from the job classes
2209 (use the setter functions of MSeqeunce instead)
2210
2211 - general: ProcessFile has been renamed to Process in all job classes,
2212 because ProcessFile is missleading
2213
2214 - general: The storage of the palette in MHCamera is now possible
2215
2216 - general: new bits describing unsuitable and unreliable pixels have
2217 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2218 kDeadPedestalRms, kFluctuatingArrivalTimes
2219
2220 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2221 versions newer than V200404070
2222
2223 - general: support for cc file versions newer than V200504130. Added
2224 support for active loads (MCameraActiveLoad) and central pixel
2225 (MCameraCentralPixel)
2226
2227 - general: added new histograms for image parameters versus size
2228 (MHVsSize)
2229
2230 - general: The eventloop now automatically calls PrintStatistics
2231
2232 - Status Display: Improved support for printing:
2233 + A default can now be set in .rootrc (for more details see
2234 MStatusDisplay::PrintPS)
2235 + A print dialog is opened so that printer and command line
2236 can be canged
2237
2238 - showlog: improved such that it handles different verbosity levels
2239 more accurate now. This mean you can suppress output when
2240 using showlog.
2241
2242 - showplot: improved
2243 + The new graphics formats have been implemented
2244 (pdf, svg, png, jpg and xpm)
2245 + Implemented an interface for printing. Because you can change
2246 the printing command from the command line you can use all
2247 the nice postscript tool. To print a booklet for example call:
2248 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2249 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2250 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2251
2252 - callisto: fixed a bug in the recognition of the calibration bit
2253 pattern. Concerns only intensity calibration. (The strength of the
2254 intensity has been updated in some cases)
2255
2256 - callisto: add a filter against PIN Diode events when running over
2257 calibration runs since some of the recent calibration runs have
2258 been taken with Pin Diode.
2259
2260 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2261 39943, 44833 in the calibration (MCalibColorSet)
2262
2263 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2264 been set to 1e-18 in callisto_Dec04_Jan05.rc
2265
2266 - callisto: in callisto_Dec04Jan05.rc: set value for
2267 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2268 statistics for the calculation of the mean pulse time
2269 of the cosmisc
2270
2271 - callisto: the charge limit in the calibration has been raised
2272 from 2.5 to 4.5
2273
2274 - callisto: new setup read from callisto.rc
2275 + MCalibCalcFromPast.fNumEventsDump
2276 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2277 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2278
2279 - callisto: MExtractTimeAndChargeSpline extractor:
2280 + The integration ranges were shifted by 0.2 FADC slices to the right.
2281 + unreliable handling of floating point values caused different
2282 results on different platform or with different compiler options:
2283 The new algorithm is numerically exact and more accurate because
2284 it doesn't calculate the integration position by multiple times
2285 adding the step-size (which results in numerical uncertanties
2286 exspecially if multiplied with large numbers)
2287 + A lot of fixes have been introduced which effects integrating the
2288 spline at the edges of the valid range. In this case any memory
2289 was randomly accessed. This behaviour can be tested replacing
2290 all MArrayF by TArrayF which perform a range check (but of course
2291 they are a lot slower)
2292 ! No result obtained with the Spline before can be trusted! Due to
2293 random memory access it might by completely random!
2294
2295 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2296 + extraction range in the high gain to 4.
2297 + weights file to cosmics_weights46.dat
2298
2299 - callisto:
2300 + introduce the check for fluctuating arrival times.
2301 + set charge limit to from 2.5 to 4.5
2302 + introduce asymmetric exclusion due to "deviating number of phes":
2303 Default: -9.0 +4.5
2304 + make deviating number of phes unsuitable (see David's findings).
2305
2306 - callisto: fixed the display of unsuitable pixels. The old change
2307 to a real profile in MHCamera broke it.
2308
2309 - callisto: The cosmics filter is used in MJCalibration now
2310 independant of the pulser color (formaly it was used only for
2311 CT1-pulser data). The threshold of number of max empty pixels
2312 has been raised from 2% to 5% in MJCalibration. The maximum
2313 fraction of rejected event is 50% otherwise the calibration has
2314 failed. The filter now ignores unsuitable pixels.
2315 Setup the filter from callisto.rc using "ContCosmics"
2316 (see MFCosmics::ReadEnv)
2317
2318 - callisto: changed default for fgOffsetFromLogain back
2319 from -2.8 to -1.8 in digital filter.
2320
2321 - callisto: for the common extractors
2322 + MExtractFixedWindow
2323 * MExtractTimeAndChargeSlidingWindow
2324 * MExtractTimeAndChargeSpline
2325 * MExtractTimeAndChargeDigitalFilter
2326 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2327 and fResolutionPerPheLoGain
2328
2329 - callisto: Updated the hi-/lo-gain intercalibration constants
2330 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2331 hilocalib_df6.root
2332
2333 - callisto: The default lo-gain extraction window for the
2334 MExtractTimeAndChargeSlidingWindow extractor has been increased
2335 from 6 to 8 to take the stretch of the pusle into account
2336
2337 - callisto (!!!): fixed an important bug in the setting of the
2338 incoming pedestal pointer to the signal extractor extracting
2339 pedestals. This bug caused the pedestals not to be subtracted
2340 correctly in the calibration afterwards. The effect was about 10%
2341 too high conversion factors for the digital filter and the spline
2342 and more than 40% for the sliding window.
2343 The bug existed since end of February! (Markus G.)
2344
2345 - star: added muon support to star. A new tab "MHMuonPar" is
2346 displayed. The lower right plot is an estimate of the point spread
2347 function. A reference value is displayed. To get the real PSF
2348 you must compare with MC. The setup for the muon analysis
2349 is done in star.rc. More informations can be found in
2350 MHSingleMuon and MHCalibParCalc
2351
2352 - star: The weather data is now displayed in star
2353
2354 - star: MEventRateCalc handles the calculation of the event rate more
2355 accurate now in case of the start of a new run inside a sequence
2356
2357 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2358 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2359 changed only minimally
2360
2361 - ganymed: (MJCut and MJOptimize) now displayes the number of
2362 excess events versus size. The energy estimation is done in
2363 MJSpectrum (sponde)
2364
2365 - ganymed: got support for using other variables than Alpha, eg. Theta.
2366 Therefor you need a class deriving from MHAlpha which supports
2367 this variable (one is already existing: MHTheta, which is now the
2368 default in ganymed). It is setup through ganymed.rc
2369
2370 - added a full featured spectrum program (sponde) which reads
2371 ganymed output and monte carlos and compiles a spectrum
2372
2373
2374
2375 *** Version 0.9.1 (2005/04/14)
2376
2377 - Fix bug on the arrival time reconstruction when using Digital
2378 Filter (in some marginal cases (10%) times were reconstructed shifted
2379 by 0.2 slices)
2380
2381 - all executables now return 2 where in previous versions -1 has
2382 been returned (gave problems with shell-scripts)
2383
2384 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2385 also done with a intercalibration input file
2386
2387 - a bug in the time fine adjustment of the digital filter has been fixed
2388
2389 - a lot of small fixes to calling TPad::Divide with a margin==0
2390
2391 - MStatusDisplay now shows the memory usage
2392
2393 - added a memory leak statistic after the eventloop
2394
2395 - MHadronness replaced by MParameterD
2396
2397 - MEnergyEst replaced by MParameterD
2398
2399 - wobble mode can now be switched on from the data-set
2400
2401 - switched on bad pixel detection for a pedestal level
2402 which is more than 5 times the variance
2403
2404 - Fixed default paths to be correct for the new data center
2405
2406 - Fixed handling of drive data. The pointing position in now
2407 copied to MPointingPos inside star for real and MC events
2408
2409 - made sure, that the sequences in a dataset are sorted by
2410 their number to ensure the correct synchronization
2411
2412 - added all resource files necessary to handle spline extraction
2413 of signal for the late 2004 and the early 2005 data
2414
2415 - update the reference lines for the december data
2416
2417 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2418 This is important for the Dec. and Jan. data where the calibration
2419 pulse position changes much.
2420
2421 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2422 filter. This corrects only an defective extraction of the MC at
2423 low-gain signals lower than 90 phes.
2424
2425 - fixed some slowdown in calibrating data with interleaved events from
2426 Jan and Dec. As a workaround made the pretty palette the default.
2427 The inverse Deep Blue Sea has a bug which slows down long calibration
2428 runs a lot.
2429
2430 - implemented new values from new starguider report as defined
2431 in TDAS00-07 V7.1 (eg SkyBrighness)
2432
2433 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2434 in starguider report (If you merpp the same reports with this version
2435 you'll get the correct units (arcmin) but a different result
2436 than with old versions (wrong units))
2437
2438 - Now the status display can also write PNG, JPEG and XPM (other file
2439 formats are still unsupported by root)
2440
2441 - added a lot of scripts and macros in directory datacenter used
2442 for automatic processing
2443
2444
2445
2446 *** Version 0.9 (2005/03/23)
2447
2448 - Calibration is now done autmatically into photo-electrons like
2449 decided by the Collaboration Board
2450
2451 - Reference lines in the display can be read from resource file
2452
2453 - Interlaced calibration events can be handled by callisto
2454
2455 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2456 and applied in callisto.
2457
2458 - class MJCalibTest can be called by callisto
2459
2460 - callisto can now run with three data types: rawdata, rootdata, MC
2461
2462 - added two classes mreport/MReportStarguider.cc and
2463 mreport/MReportStarguider.h for implementing starguider-data
2464
2465 - the output of merpp-update now contains starguider information:
2466 MReportStarguider and MTimeStarguider
2467
2468 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2469 values were lower than they should. This was more visible for high
2470 energy (Size) events.
2471
2472 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2473
2474 - added a new loop to callisto to support the correct extraction of
2475 the pedestal and pedestal rms through the signal extractor
2476
2477 - added class to perform fourier tranformation of a hexagonal structure
2478 (MHexagonalFT)
2479
2480 - added class to perform fourier tranformation of a hexagonal structure
2481 in a tasklist (MHexagonalFTCalc) example: hft.C
2482
2483 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2484 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2485 small pixels, example: extendcam.C
2486
2487 - added possibility to write data to memory (TTree) using MWriteRootFile
2488
2489 - added possibility to read a TTree stored only in memory by MReadTree
2490
2491 - new classes to deal with the interleaved calibration events:
2492 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2493
2494 - implemented filters to callisto to skip calibration events
2495
2496 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2497 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2498 the slices by statistics
2499 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2500 signal extractor without randomization
2501 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2502 with the signal extractor with randomization (extraction window is
2503 randomly fixed)
2504 The three kind of pedestal is not yet implemented (for speed reasons) as
2505 long as nobody really needs it:
2506 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2507 extracted with the signal extractor with randomization
2508
2509 - callisto now finds the pulse position in the data automatically
2510
2511 - implemented data reduction in calibrated data by reducing the precision
2512 of the stored floating point values (pedestal, rms and signal) to
2513 roughly 0.5%
2514
2515 - fixed showplot to make file format conversion (eg. converting a
2516 status display stored in a root file into a postscript file) in
2517 batch mode possible:
2518 showplot -b --save-as-ps[=outfile.ps] infile.root
2519
2520 - Allow class names as part of filter rules, eg
2521 (MFSupercuts) && (MHillas.fSize>100)
2522
2523 - fixed a lot of stuff to allow all programs to process MonteCarlo
2524 camera files.
2525
2526 - enhanced possibility to debug reading of resource file
2527
2528 - MDataChain should handle priorities of operator more
2529 accurate now
2530
2531 - completely revised the container in which the signal is stored
2532 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2533 * the new implementation is faster and
2534 * needs less storage space
2535
2536 - FIRST version which can process Monte Carlos through the
2537 whole chain of programs (callisto, star, etc)
2538
2539 - implemented new image parameters for the border length of
2540 the shower image (MNewImagePar2)
2541
2542 - implemented wobble-mode in ganymed
2543
2544 - new class (MJOptimize) taking care of all optimization processes
2545
2546
2547
2548 *** Version 0.8.6 (2004/10/05)
2549
2550 - New combined signal and time extractor
2551 MExtractTimeAndChargeDigitalFilter
2552
2553 - The Report for the trigger section in the CC run summary has been
2554 updated, and now the IPRs (Individual Pixel Rates) are available.
2555
2556 - new macros for database interaction: filldotrun.C, filldotrbk.C
2557
2558 - added new program which can convert colored output which was redirected
2559 into a file back into colored text (for example to display it with
2560 more): showlog
2561
2562 - added new program to display an MStatusArray of plots (stored with
2563 MStatusDisplay) from a file: showplot
2564
2565 - Added support for Sequences (MSequence). Sequences are blocks of run
2566 files containing the same calibration and belonging to the same
2567 source
2568
2569 - Added a new task (MTaskEnv) which can be used in setup files to switch
2570 between different tasks (for example to choose a signal extractor)
2571
2572 - Implemented automatic file splitting in MWriteRootFile
2573
2574 - After image cleaning an island index is assigned to all used pixels.
2575 The index corresponds to the order of the islands in size.
2576
2577 - added a cleaning which takes signal height _and_ arrival time into
2578 account: probability cleaning (for more details see MImgCleanStd)
2579
2580 - added a cleaning which takes takes the absolute number of photons
2581 times the area ratio as cleaning level
2582 (for more details see MImgCleanStd)
2583
2584 - Changed calculation of image parameters such, that it can be done
2585 for all used pixels or the pixels with a defined island index only
2586
2587 - implemented new image parameters displaying the number of islands,
2588 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2589
2590 - event display in executable changed to support also calibrated files
2591 (done with MJCalibrateSignal)
2592
2593 - added program doing the calibration and the signal extraction
2594 and signal calibration: callisto Most part of the setup is done
2595 by a resource file: callisto.rc
2596
2597 - implemented support for pixels with negative IDs (Raw file format
2598 version 4)
2599
2600 - implemented an new option in merpp (--auto-time) to get the time
2601 range for cc and/or caco data from the run header of the raw data
2602
2603 - New star-program (star and MJStar). Taking calibrated data from
2604 callisto/MJCalibrateSignal as input. The setup is done through
2605 a resource file: star.rc
2606
2607 - Added possibility to setup the eventloop in the mars-executable
2608 Camera Display by a resource file: mars.rc
2609
2610 - The the mars-executable Camera Display can now also read
2611 calibrated data files written by callisto/MJCalibrateSignal
2612
2613 - Added a new class which can calculate the source position in
2614 the camera from a pointing model known to be correct and
2615 the pointing model used for observations (MSrcPosFromModel)
2616
2617 - added a new version of the class calculating the effective on-time
2618 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2619 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2620 MHTimeDiffTheta.
2621
2622 - added the possibility to count how often a signal is above (or
2623 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2624 can replace MHTriggerLvl0)
2625
2626 - added ore convinient ways to set the axis-titles of your histograms
2627 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2628 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2629
2630
2631
2632 *** Version 0.8.5 (2004/08/06)
2633
2634 - new Signal Extractors: MExtractFixedWindowSpline
2635 and MExtractAmplitudeSpline
2636
2637 - implementes interleave in merpp to be able to merpp parts of a file
2638
2639 - implemented force-functionality to merpp
2640
2641 - star display to display star catalogs (MAstroCatalog)
2642
2643 - star display to 'mirror' stars to the camera (MAstroCamera)
2644
2645 - implemented a new cleaning option which allows cleaning scaled with
2646 the real ratio of the rms depending on the pixel size, not only the
2647 square root of the pixelsize (MImgCleanStd, MCameraData)
2648
2649 - removed obsolete MBlind* classes
2650
2651 - Signal extractor taking the AB flag into account implemented (this makes
2652 an odd number of slices for signal extraction possible
2653 (MExtractSignalABcorr)
2654
2655 - implemented a class extracting the pedestal from the raw-data (events)
2656 itself using empty lo-gain (MpedCalcFromLoGain)
2657
2658 - Added mean values to MPedPhotCam
2659
2660 - Added Makefile for Darwin (this OS is NOT officially supported!)
2661
2662
2663
2664 *** Version 0.8.4 (2004/04/19)
2665
2666 - new fast arrival time extractor using cubic splines:
2667 MExtractTimeFastSpline
2668
2669 - implementes multi-argument support in MDataChain
2670 ("pow(a, b)")
2671
2672 - implemented double reference support in MDataChain
2673 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2674
2675 - added support in MF for expressiond like
2676 "MHillas.fWidth<2*<MHillas.fLength"
2677
2678 - MDataChain is now able to support variables like [0], [1], ...
2679 which can be used in fit functions as parameters. The interface
2680 is implemented through the new virtual function
2681 MParContainer::SetVariables
2682
2683 - added new class MArrivalTimeCam/MArrivalTimePix:
2684 Storage containers to hold the ArrivalTime of the camera/pixel
2685
2686 - added new classes for the calibration of relative arrival times:
2687 MCalibrationRelTimePix and MCalibrationRelTimeCam
2688
2689 - added new classes to extract the signal of the blind pixel and the
2690 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2691
2692 - added new classes for the bad-pixels treatment (MBadPixels*)
2693 which are more powerfull than the old ones (MBlindPixel*)
2694 and will replace them.
2695
2696 - added filter against cosmics: MFCosmics
2697
2698 - added new class MArrivalTimeCalc2:
2699 Calculates the arrival time as the signal weighted mean of the time
2700 slices in the maximum window
2701
2702 - added a new macro call pointspreadfucntion.C that fits with a 2D
2703 gaussian the DC spot for an star. It gives you the RMS of
2704 the PSF and the center of the star, very useful for misspointing
2705 studies.
2706
2707 - added support for multi-telescope camera files. Added classes
2708 MStereoCalc and MStereoPar, classes to calculate and store shower
2709 parameters calculated from the data of two telescopes, for the MC
2710 studies regarding the MAGIC clone.
2711
2712 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2713 MC data calibrated in photons instead of ADC counts.
2714
2715 - added three macros to show the calibration and analysis chain of
2716 MC data. The macro starmc.C does both calibration and analysis, producing
2717 an output containing Hillas parameters for each event. The macro
2718 mccalibrate.C does just the calibration and writes out a file containing
2719 pixel information in photons instead of FADC data. The macro starmc2.C
2720 reads in such a file and produces an output with Hillas parameters.
2721
2722 - added MPedPhotCalc to compute pedestals in units of photons, see
2723 macro pedphotcalc.C
2724
2725 - added all class to perform the calibration, see macro calibration.C
2726
2727 - added class MFFT to perform Fast Fourier Transforms
2728
2729 - added class MSimulatedAnnealing to perform simulated annealing
2730 minimizations
2731
2732 - added new macro bootcampstandardanalysis.C which holds the skeleton
2733 of the analysis chain discussed in the december bootcamp.
2734
2735 - added support for DAQ raw data file format V2
2736
2737 - implemented an arbitrary time stamp for the events from raw-data
2738 files with file version<3. It is calculated from the run number,
2739 the date of start and the FADC clock tick from the first module
2740
2741 - implemented the correct decoding of the event time-stamp
2742 coming from the DAQ for raw-data files with file-version>2
2743
2744 - added a new classes storing the pedestals in units of photons:
2745 MPedPhotPix, MPedPhotCam
2746
2747 - added support for DC current files from the camera control
2748
2749 - added support for start- and stop-time when merpping report files
2750
2751 - added MReportCC storing the weather data from the CC-REPORT
2752
2753 - added class to fill trainings and test matrices (MTFillMatrix)
2754
2755 - added a filter performing a software trigger (MFSoftwareTrigger)
2756
2757 - Added classes to perform parts of the standard analysis (Jobs):
2758 + MJPedestals
2759 + MJCalibration
2760 + MJExtractSignal
2761 Note: All of them are preliminary!
2762
2763 - Added Iterator to iterate over files giving only the run-number
2764
2765 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2766 the evolution of a sector vs time
2767
2768
2769
2770 *** Version 0.8.3 (2003/12/05)
2771
2772 - adapted Random Forest classes to allow the use with MC
2773 multi-telescope files which can be produced with the coming
2774 camera version 0.7.
2775
2776 - added classes to read and interprete central control report files
2777 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2778
2779 - enhanced merpp (the executable) to support .raw and .rep files.
2780
2781 - added classes for light calibration (MCalibration* and
2782 MHCalibration*) by Markus Gaug. Further work has to be and will
2783 be done soon.
2784
2785 - Added a preliminary 'synchronizer' (MReadReports) which will
2786 replace MReadMarsFile as soon as it is finished.
2787
2788 - Added a tutorial macro demonstrating how report files are merpped
2789 and how they can be read from the root file in the correct order
2790 of time (readrep.C)
2791
2792 - Added a generalized histogram (similar to MH3) called MVsTime
2793 which allows to plot variables (or rules - MDataChain - of
2794 variables) vs time. For an example have a look at tempvstime.C.
2795
2796 - Changed the name of the event trees:
2797 + Events --> Events
2798 + PedEvents --> Pedestals
2799 + CalEvents --> Calibration
2800
2801 - changed name of MTime in the event trees from MRawEvtTime to MTime
2802
2803 - added displaying the sector indices to the mars event display
2804
2805 - Magic Online Analysis (MOnA) implemented in a first version
2806 (see mona.cc, MOnlineDump and MOnlineDisplay)
2807
2808 - added classes to calculate event rate
2809 (preliminary: MEventRateCalc, MEventRate)
2810
2811 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2812
2813 - added classes dealing with the telescope pointing position (MPointing*)
2814
2815 - implemented the 'final' Mars time stamp based on some experiences with
2816 the new 'Synchonizer'
2817
2818
2819
2820 *** Version 0.8.2 (2003/11/10)
2821
2822 - accelerated standard analysis by a factor of 6-8 ...
2823 + doing precalculations in MGeomCam for the pixel area ratio
2824 + creating a look up table for the single pixels in MCerPhotEvt
2825
2826 - added task to calculates weights in case you want to 'change'
2827 the energy spectrum of a monte carlo file
2828 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2829
2830 - added a new executable star which implements the
2831 star.C macro as precompiled executable. Currently a flexible
2832 setup is not possible, but a 'input card' setup will follow.
2833
2834 - Starting to implement Multi-Telescope-Support based on the
2835 upcomming camera version 0.7. The base for a general support
2836 is implemented and the star-functionality is proven to work.
2837
2838 - Replaced Event-Display in and Camera-Display in the Mars GUI
2839 executable by a more convinient display base on MStatusDisplay.
2840
2841 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2842
2843
2844
2845 *** Version 0.8.1 (2003/10/20)
2846
2847 - added signal subtraction for pure on data by means of fitting
2848 the background in the off region or by performing a combined
2849 signal/background fit. Provides necessary histograms for
2850 obtaining energy spectra and a light curve.
2851
2852 - added classes to perform and study the selection of the
2853 2nd Level Trigger on MC data (example in triglvl2.C macro)
2854
2855 - added pedestal calculation
2856
2857 - implemented "democratic cleaning" (tail cut value proportional
2858 to pixel area) according to Wolfgang's suggestion.
2859
2860 - added Sigmabar treatment (calculation and basic histogramming)
2861
2862 - added basic routines to apply padding
2863
2864 - added first implementation of MARS-based source visibility plotter
2865 (needs to be linked against slalib, preliminary version)
2866
2867 - enhanced functionality of data chains: random numbers, conversion
2868 functions and access to MHMatrix objects
2869
2870 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2871 numbers under certain circumstances (runs with 0 events included)
2872
2873 - fixed a bug in the general filter MF (didn't work on some systems
2874 at all)
2875
2876 - fixed a bug in chaining files, which caused the analysis to crash or
2877 ignore files
2878
2879 - implemented more geometry classes describing the parameters used
2880 to simulate the PMT camera
2881
2882 - added new Monte Carlo classes containing the setup of the different
2883 programs in the MC chain.
2884
2885 - added a (preliminary) general task to evaluate chi-square of a given
2886 parameter in an eventloop.
2887
2888 - first implementation of a container describing the observatory
2889 location (Long, Lat, etc)
2890
2891 - added Random Forest - method for g/h-separation
2892
2893 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2894 (this means, that it is compiling, but not yet fully tested)
2895
2896 - added a new status display which can show the present status
2897 of histograms while an eventloop is running (MStatusDisplay,
2898 an example can be found at status.C)
2899
2900 - reorganized directories:
2901 classes describing the image --> mimage
2902 classes containing Monte Carlo Histograms --> mhistmc
2903 classes for Random Forest method --> mranforest
2904
2905 - added (event-)weights to fill histograms
2906
2907 - colors in logging output to screen
2908
2909 - changes to the Image Parameter declaration:
2910 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2911 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2912 + MHillasExt now derives from MParContainer instead of MHillas
2913 --> Files written with the old definition are more or less unreadable
2914
2915 - reading of reflector files
2916
2917 - display data from reflector files in the camera
2918
2919 - implemented currents (and display them in the camera)
2920
2921 - logarithmic scale in camera
2922
2923 - added class to iterate through directory contents (MDirIter)
2924
2925
2926
2927 *** Version 0.8 (2002/11/18)
2928
2929 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2930
2931 - corrected 48(!) wrong entries in the Next Neighbor table of the
2932 Magic Camera (all in the inner part of the outer ring, mostly
2933 missing a single NN)
2934
2935 - Fixed a bug in the table describing the Next Neighbours of the
2936 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2937 have any neighbour)
2938
2939 - changed trigrate.C: now it calculates the pure NSB triggers from
2940 a camera file (generated with no showers), so there is no need
2941 to introduce them by hand in the BgR array (for more details
2942 please ask Abelardo)
2943
2944 - added MHHadronness (and MHadronness) as a general facility to evaluate
2945 the quality of a gamma-hadron seperation method
2946
2947 - changed MWriteAsciiFile to accept rules (MDataChain)
2948
2949 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2950 must be replaced by calles to MWriteAsciiFile::AddColumn and
2951 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2952 changed.
2953
2954 - Implemented generalized event-matrices (one row per event)
2955 (MHMatrix)
2956
2957 - implemented the one dimensional composite probabilities
2958 (MHCompProb, MCompProbCalc, comprob.C)
2959
2960 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2961 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2962
2963 - Added a camera display displaying the pixel numbers to the
2964 event display gui.
2965
2966 - Added Monte Carlo Informations to event display gui
2967
2968 - Changed the camera display to display the pixel numbering
2969
2970 - Added three buttons to the camera display to change the palette
2971
2972 - Added the number of used and core pixels after image cleaning
2973 to MHillas
2974
2975 - Changed the algorithm used in MHillas according to TDAS 02-03
2976
2977 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
2978
2979 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
2980
2981 - Added fCosDeltaAlpha to MHillasSrc
2982
2983 - The numbers of photons used to calculate fConc and fConc1 in
2984 MHillasExt are now scaled with the pixel size, so that one get
2985 a four times smaller value for the bigger pixels in the outer ring.
2986
2987 - added new task to smooth the camera contents (MCameraSmooth)
2988
2989 - added possibility to use interpolated pixel values for blind pixels
2990 instead of removing it completely from the analysis
2991
2992 - Implemented the possibility to save the whole eventloop with
2993 its setup to a file. This information can be read and from
2994 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
2995 and MEvtLoop::MakeMacro. If you find something not working, please
2996 report - this stuff is still in a beta phase.
2997
2998 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
2999 file having crab starfield, but also for all following files - fixed
3000
3001 - MTaskList::PrintStatistics can now be instructud to print also the
3002 title, too: use PrintStatistics(0, kTRUE)
3003
3004 - Changed the image cleaning so that pixels with to many 'used'
3005 neighbors are left used (to get rid of 'holes' in events)
3006
3007 - Introduced more output to the camera displays
3008
3009 - Added an array of histograms (eg one hist per run), MHArray
3010
3011 - Added a _preliminary_ version of the reader for CT1 PreProc files
3012 (MCT1ReadPreProc)
3013
3014 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3015 (thanks to Raquel)
3016
3017 - added the first energy estimator (MEnergyEstParam, estimate.C,
3018 estfit.C) using a parametrization
3019
3020 - Added some new Monte Carlo paremeter containers used to store
3021 setup information from the MC chain (MMcConfigRunHeader,
3022 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3023
3024
3025
3026 *** Version 0.7 (2002/04/30)
3027
3028 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3029 the pedestal mean value was saved incorrectly. For files from
3030 this versions we substract 0.5 from the pedestal mean.
3031 WARNING: This may effect your results, so don't wonder...
3032
3033 - First implementation of an algorithm using only triggered events
3034 for the collection area calculation
3035
3036 - Ascii Output can now also be used for parameter containers which
3037 doesn't overload MParCointainer::AsciiWrite
3038
3039 - The Ascii Output is now also capable of writing single data members
3040 of one container
3041
3042 - You are now able to change the order of the values written to the
3043 ascii file
3044
3045 - You can now specify a conversion factor for each data member written
3046 to an ascii file. This may be usefull to change the units of the
3047 data member (eg. degrees instead of millimeters in case of the
3048 hillas parameters)
3049
3050 - Replaced old MHillas by a new structure which allows you to extend
3051 the parameters stored in MHillas very easily:
3052 see MHillas and MHillasExt
3053
3054 - Added classes to handle source dependancy of image parameters:
3055 see MHillasSrc
3056
3057 - Added container (MBinning) to have a standard input for the binning
3058 in different histograms (eg. the Energy bins should be the same in
3059 all histograms)
3060
3061 - Changed Hillas histograms from mm to deg
3062
3063 - Added the flexible binning to the hillas histograms
3064
3065 - Added a filter for the alpha parameter (MFAlpha)
3066
3067 - It is now possible to write single data members of a class object to
3068 an output stream instead of the whole container only
3069
3070 - Added a generalized filter for a data member:
3071 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3072
3073 - Added a generalized Filter parser for more difficult filter rules
3074 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3075
3076 - Added new Monte Carlo histograms:
3077 MHMcEnergyImpact and MHMcEfficiency
3078
3079 - Added many new histograms needed for the flux calculation.
3080
3081 - Added a generalized histograms which can fill and show up to three
3082 data members in either a one-, two- or three-dimensional histogram, eg:
3083 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3084
3085 - Added:
3086 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3087 * calculation of <Theta> as a function of time (MHThetabarTime)
3088 they are needed in the flux calculation in
3089 order to select for a given bin in Theta (or time) the appropriate
3090 effective collection area, which is assumed to be given as a function
3091 of Theta and the true energy
3092
3093 - Added calculation of the migration matrix in the energy
3094 (MHMcEnergyMigration):
3095 the migration matrix describes the migration from the true (E_true)
3096 to the estimated energy (E_est); it is needed to determine the
3097 distribution of E_true from the measured distribution of E_est
3098 by unfolding
3099
3100 - changed the color palette in the camera display to DeapSea.
3101
3102
3103
3104 *** Version 0.6 (2002/01/15)
3105
3106 - Introduce the option of disable pixels (MBlindPixels and
3107 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3108 able to deal with Star Field NSB.
3109
3110 - Fixed a bug in the pedestals substraction
3111
3112 - Introduced verbosity levels
3113
3114 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3115
3116 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3117 work correctly (thanks to Abelardo)
3118
3119 - Introduced correct treatment of the diffuse Night Sky Background
3120 and NSB (MMcPedestalNSB)
3121
3122 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3123
3124 - Introduced MMcRunHeaders which contains monte carlo run informations
3125
3126 - Added a 'Print'-Task (MPrint) which calls the Print function
3127 of a parameter container for each event
3128
3129 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3130
3131 - changes to be more efficient with root 3.02/06
3132
3133 - root 3.02/06 fixes:
3134 + the memory leak when reading MRawEvtData
3135 + loosing more time than necessary to update the progress bar
3136
3137 - MWriteAsciiFile is now capable of writing more than one container
3138 in a line. For example: To be able to write Monte Carlo and
3139 Hillas values (energy and alpha) in one line.
3140
3141
3142
3143 *** Version 0.5 (2001/11/06)
3144
3145 - Added new GUI functionality (Analysis)
3146
3147 - Added a camera display to be able to display events in the camera
3148 together with the calculated hillas ellipse
3149
3150 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3151 object at any state of the analysis, so that the output are several
3152 states
3153
3154 - Fixed a bug in the collection area error calculation
3155 (Thanks to Ciro and Abelardo)
3156
3157 - Fixed a bug which causes merpp to crash in some environments
3158
3159 - Implemented auto enabling scheme for Branches to speed up reading
3160 a lot (see MReadTree and MTask)
3161
3162 - Fixed a bug in the Histogram classes which caused histograms to
3163 be written to a file by MWriteRootFile without request
3164
3165 - changed the object I/O from the old stylish root I/O to the new
3166 'auto evolution scheme' This was done only for classes which are not
3167 yet used in Monte Carlo files, so that these files are still readable.
3168
3169 - Added support for a progress bar in MEvtLoop and MReadTree
3170 (see the Analysis Window in Mars for an example)
3171
3172 - Fixed a bug in the package creation which disturbed the conversion
3173 between a mars version unpacked from a tar file and the repository.
3174
3175 - Changed the code to writer merpped (converted into root format)
3176 raw files, to get faster (around 10%)
3177
3178
3179
3180 *** Version 0.4 (2001/09/20)
3181
3182 - This release is made to compile on a root version >= 3.00
3183
3184 - Fixed a bug which causes MReadTree to read the first file only
3185
3186 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3187
3188 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3189
3190 - Added a task to write several container to a root file (MWriteRootFile)
3191
3192 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3193
3194 - Added calculation of the collection area (MMcCollectionAreaCalc)
3195
3196 - fixed some bugs in the Hillas calculation
3197
3198 - added filters to be able to control the task execution dependent on
3199 a parameter (for example: the number of level 1 triggers in a MC-file)
3200
3201
3202
3203 *** Version 0.3 (2001/04/23)
3204
3205 - Many demo macros added
3206
3207 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3208
3209 - Hillas Calculation added
3210
3211 - Standard image cleaning available
3212
3213 - MReadTree is now able to handle more than one file
3214 (Remark: of the same structure)
3215
3216 - Now we are able to display events in a first version of the
3217 Camera event display. To do this we must run the macro
3218 "macros/readCT1.C" to read data from CT1.
3219
3220
3221
3222 *** Version 0.2 (2001/01/24)
3223
3224 - First Implementation of a Gui to read the raw data. Start the
3225 gui with the command mars.
3226
3227
3228
3229 *** Version 0.1 (2000/12/20)
3230
3231 - First official release 0.1
3232
3233 - Changes:
3234
3235 + changed calling style of MRawPixelIterator from do...while to
3236 while-loop