source: trunk/MagicSoft/Mars/NEWS@ 9411

Last change on this file since 9411 was 9410, checked in by tbretz, 17 years ago
*** empty log message ***
File size: 132.2 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;showplot:
6
7 * If a file without a MStatusArray is opened all object (not just
8 canvases) found in the file are drawn. Note that this may result
9 in empty tabs.
10
11 ;ganymed:
12
13 * added new starguider calibration for sequences since 1000534
14
15
16
17== Version 2.3 (2009/03/07) ==
18
19 ;SUGGESTION
20
21 * There is no need to re-run any data because no change took place which
22 could have an effect on the output. However, if you want a
23 meaningful SrcPos plot for your MCs in sponde you must re-process
24 star for your MCs first.
25
26 ;REMARK
27
28 * File produced with this release containing a gamera geometry (which
29 are basically all files we produce per default) will not be readable
30 by older releases.
31
32 ;general
33
34 * fixed a few small bugs which could cause the display to crash in ganymed
35 and sponde
36
37 * in sequence file the date can now be omittet. In this case the
38 leading date with the underscore is missing in the expected filename
39
40 * the geometry class now also supports other geometries than just hexagons
41
42 ;automation
43
44 * added magnetic field Azimuth direction (ARRANG), currently
45 at ~ -7deg at La Palma
46
47 ;database
48
49 * plotdb.php: added default (sequences) for startup, added possibility
50 to set size of plot
51
52 * added a new table ''RunDataCheck'' which containes the rates after
53 image cleaning for every run which succeeded star. It can be
54 plotted using ''plotrundb.C''
55
56 ;merpp
57
58 * added support for Arehucas Version >= 200812140
59
60 * added support for Arehucas Version >= 200809030
61
62 ;mars
63
64 * The display now also displays the trigger pattern
65
66 * The display can now display ceres reflector (_R_) files
67
68 ;ceres
69
70 * added a uniformly distributed one-bin time jitter for the start of the
71 digitization. Otherwise the first photon would be digitized always with
72 the same alignment to the bins
73
74 * Added a plot showing the production height of the photons
75
76 * Moved the particle id from the event header to the run header
77
78 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
79
80 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
81
82 * Added many new options to control the tasks. For deatils see ''ceres.rc''
83
84 * Removed obsolete plots in pedestal and calibration mode
85
86 * Removed the non-NightSky photons from the plots where they are just
87 disturbing
88
89 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
90
91 * The daq event number now represents the readout number
92
93 * The camera ''electronics'' can now be ''switched off''
94
95 * A new tab ''Info'' now display basic things like the reflector
96 layout
97
98 * Improved reading speed for corsika files
99
100 * Improved memory handling (if a large ampount of memory was needed
101 for a single event all further events were stored in the same
102 memory and it was never freed, so the program took this memory
103 until the end)
104
105 * Converted the code from MMCS' reflector program to MSimAtmosphere
106 (instead of the tables build in for MAGIC Winter and Summer
107 atmosphere we use the values written by Corsika fitted to the
108 tabulated atmosphere given as input)
109
110 * For caluclating the displayed image parameters in ceres a basic
111 image cleaning removing isolated pixels is now done.
112
113 * The magnetic field direction (ARRANG) is now taken into account
114
115 * Added plot for the energy threshold after trigger ''Threshold''
116
117 * Added plot for the effective collection area after trigger ''TrigArea''
118
119 ;star
120
121 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
122
123 * The definition of fConcCore has slightly changed. The numbers
124 might decrease a little bit (the effect should be rather small)
125
126 ;ganymed
127
128 * added pointing model 328198
129
130 ;sponde
131
132 * The SrcPos plot for your MCs was so far meaningless because it just
133 displayes the MSrcPosCam data from the input star-files. Unfortunately,
134 this containes was never written to the star-files yet.
135
136 * A new Tab 'OnTime' is available which is an effective on-time
137 fit as in star but for all data. This is mainly for manual cross-check
138 of the effective on-time
139
140 * In some circumstances it might be necessary to re-calculate the
141 eff. on-time from the fit in the new tab, e.g. when a zenith distance
142 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
143
144 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
145 it to its own output file (for convinience)
146
147
148
149== Version 2.2 (2009/01/30) ==
150
151 ;SUGGESTION
152
153 * This release doesn't contain a major change which is expected to
154 change your results. Nevertheless there are small changes to
155 the calibration which can effect at least the first few hundred
156 events in any (mainly MUX and even more SUM) sequence a little bit.
157 So it is recommended although not necessary to reset your sequences
158 in the database before further processing.
159
160 ;NEW
161
162 * A first implementation of a Monte Carlo simulation program
163 (ceres - Camera Electronics and REflector Simulation) has been
164 implemented. It can simulate a full telescope already including
165 a complete reflector simulation and a flexible trigger and readout
166 simulation. Currently, no perfect setup is implemented and
167 especially the output of the program (data structure) should
168 be considered alpha state. Also the user interface is not yet
169 ready.
170
171 ;general
172
173 * All command line options after -- are now interpreted as
174 arguments (usually everything which doesn't start with a minus)
175 rather than options (usually everything which starts with a
176 minus). This allows to use file names starting with a -
177
178 * In all resource files you can now initialize the random number
179 generator. For details see: MJob::InitRandomNumberGenerator
180
181 * added a new program called ''readcorsika''. It's purpose is (in analogy
182 to readraw and readdaq) to read a Corsika output file (for now
183 only cherenkov output is supported) and print its contents in a
184 human readable form. It can also write the contents of this file
185 into a root-file.
186
187 * The calculation of the maximum distance to the origin in a MGeomCam
188 has been improved (edges might be further away than the sides).
189 This is just a tiny change but it might change the appearance of
190 the radial profiles a little bit.
191
192 * The default binning of the center-of-gravity plot has slightly been
193 increased
194
195 ;Database
196
197 * Added informations about the DC currents (fMinCurrents, fMedCurrents
198 and fMaxCurrents). The values are retrieved from the plots showing
199 the average DC currents of all pixels versus time.
200
201 * Websites with tables have now the opportunity to remove lines
202 ('-' button at beginning of each line) and get all lines back
203 ('+' at top of the column)
204
205 * Websites: added option to query only sequences containing sumtrigger
206 events
207
208 * Websites: added option to group by date (year, month, night) for runs
209 and sequences and enabled that combining of different group-bys,
210 e.g. status, date and source is possible
211
212 ;automatic analyis
213
214 * Rewritten producing plots in the web.
215 New plots, namely the output of plotoptical.C (extinction curve from
216 KVA), plotstat.C (status of the automatic analysis (percentage of
217 processed, analysed data etc.)) and plotusage.C (statistics of the
218 condor usage in the data center) has been are available now next to the
219 plots of plotdb.C
220 Mean values from the plots (output of the macro) are provided in a
221 txt file now.
222 The creation of the plots for callisto, star and ganymed in the web is
223 now steered via database. Consequently the plots are faster and
224 reliable up-to-date.
225 For all plots, a new layout is available facilitating the browsing
226 through the plots and providing additional information on the
227 displayed values. (tabs.php) These plots are linked from the DB
228 websites and the wiki.
229
230 ;statusdisplay
231
232 * The ''Loop'' entry in the menu bar now contains an option to pause
233 the loop and to process single events.
234
235 ;merpp
236
237 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
238 instead of RunHeaders)
239
240 * Now allows to merpp files newer than 2008/09/03.
241
242 * Added fixes for wrong (wrong or double) run- and file-numbers
243 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
244
245 ;callisto
246
247 * Extracting the pulse position for the pulse position check events
248 with sum trigger were denied. This decreased the statistics
249 extremely and therefor the resulting puse position was calculated
250 quite weak. Now sum events pass the calculation if and only if they
251 have also a level 1 trigger.
252
253 * the extraction of pedestal events and pulse position from the
254 first data events is now more automatic and makes sure that
255 a more precise number of events is extracted independent of
256 the ratio with which pedestal events or events with signals
257 are contained in the data.
258
259 * Updated Muon calibration constants for all MUX data (teh changes were
260 all smaller than 5%)
261
262 ;star
263
264 * For the calculation of the effective on time all sum-triggered events
265 were skipped. Now all Level1-triggeres events will pass. This might
266 result in a slight inaccuracy of the effective on time.
267
268 ;ganymed
269
270 * If the source position is more than 1deg away from the camera
271 center an error is raised now.
272
273 * Hopefully fixed the bug ''ganymed crashes when resized''
274
275 ;sponde
276
277 * Fixed a problem which causes the fitted spectral slope to be displayed
278 incorrectly. If you use MJSpectrum::FormFlux in your macros make
279 sure that the parameter 0 of your fit is negative.
280
281 * Added a histogram showing the read source position of your MCs
282
283
284
285== Version 2.1.1 (2008/08/04) ==
286
287 ;Database
288
289 * Added the median number of photo electrons from the calibration
290 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
291 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
292
293 * Added fTotOnTime, which is the on-time as given by the run-headers
294 (in contradiction to fAbsOnTime which comes from CC)
295
296 * Added new primaries for the new data structure (Magic II): for the
297 tables dealing with sequences (SequenceBuild Status, Sequences,
298 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
299 this is the telescope number (fTelescopeNumber) for the tables dealing
300 with runs (RunData and RunProcessStatus) this is in addition the file
301 number (fFileNumber)
302
303 * Added column fPriority to the status tables to be able to steer the order
304 in which the data is processed. As default the run, sequence and dataset
305 number are used.
306
307 ;automatic analyis
308
309 * Adapted scripts to the new data structure: They can handle now different
310 telescopes (getting the information as usual from the database).
311 The paths for Magic 2 are not yet implemented.
312
313 ;general
314
315 * should work now with root 5.20/00 (please note that root 5.20/00
316 we encounter crahses in the status display which are ot yet
317 understood)
318
319 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
320 instead of the base name of the file. This makes them easier to
321 access from the code
322
323 * Default Monte Carlo names in MSequence do not require the _E at
324 the end anymore
325
326 * where abrrevating a sequence file with a sequence number is possible
327 also "telescope:sequence" is now accepted, e.g.:
328 star 2:2000123 --out=output
329 see the programs' help for more details.
330
331 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
332 from the database. See the constructors for more details.
333
334 * MReadTree now supports friends
335
336 * MReadTree can now read also files not written by MARS and store
337 the data encapsulated in emulated MParContainers
338
339 * added a new starguider calibration valid since 15.1.08
340
341 ;showplot
342
343 * showplot can now read more than one file at once. This is especially
344 inetersting if reading files containing pure canvases
345
346 ;merpp
347
348 * we merpp the dc currents now also from the camera reports (they have
349 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
350
351 * In the automatic analysis we omit merpping of the currents from the
352 caco files and use the lower rate camera reports from the cc files
353 instead
354
355 * merpp has been redisigned to allow merpping of the cc-reports
356 of a whole sequence. This allows to design a very simple analysis:
357 mkdir output
358 ./callisto 100776 --out=output
359 ./merpp 100776 output
360 ./star 100776 --ind=output --out=output
361 Instead of the sequence number also sequence files are accepted.
362
363 * Implemented a fix for run-numbers between 1001348 and 1001396
364 which were incorrectly assigned by the cc.
365
366
367 ;callisto
368
369 * added a filter again which was was removed in the last release.
370 it removed the most brightest events. This should not change
371 any analysis result because these events are so bright that
372 they cannot be analysed anyway, but the bad-pixel plots doesn't
373 show outliers.
374
375 * updated muon calibration constants for the periods 51-57,
376 58-63 and 67-
377
378 ;star
379
380 * The camera currents are now displayed with the rate of the camera
381 reports instead of the caco reports
382
383 ;ganymed
384
385 * if mc camera files are new enough (>=8) the source position in the
386 camera is now calculated from the stored telscope and shower
387 orientation (Note, that this might not be suitable in all cases
388 depending on the aim of the study. These case still needs
389 implementation)
390
391
392
393== Version 2.1 (2008/06/18) ==
394
395 ;Database
396
397 * introduced average temperature and wind speed from star-files
398
399 * introduced average values from Pyrometer (mainly Cloudiness)
400
401 * introduced the ratio of accepted calibration events in the
402 calibration run
403
404 * introduced the average rates of the different trigger pattern,
405 e.g. the rate of pedestal and calibration events, from the signal-file
406
407 ;general
408
409 * fixed GroupBy options in plot*.C macros
410
411 * only display KVA points (not the Tuorla points) in plotoptical.C
412
413 * all programs now allow to add resources to the ones from the resource
414 file or overwrite them from the command line. This can be done like this
415 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
416 if something seems to be wrong you can debug what the program is doing
417 using the option --debug-env=3
418
419 * increased the diversity of debug levels. That also means that with -v3
420 you get now less output, i.e. only the output which is important for
421 an analysis. To get more output which helps for debugging try 4, 5 and 6.
422
423 * fixed a problem in the task synchronizing the reading of the reports
424 and the data stream. The effect was that in some circumstances the last
425 events of some trees could have been skipped. Since this is only a
426 very tiny part of the data no severe effect to your analysis results
427 is expected (an exception might be very short, i.e. singel runs,
428 datasets).
429
430 * Dataset file now allow to include the sequence file directly within
431 the dataset file and also allow to exclude single runs from the dataset.
432 (for more details see Class reference of MDataSet)
433
434 * Sequence files now allow for excluding runs from the analysis
435 (for more details see Class reference of MSequence)
436
437 * added code to process the sum-trigger flag
438
439 * the histogram classes MH3 and MHn now support profile histograms
440
441 * the histogram classes MH3 and MHn now support labels at the axis
442
443 * the Random Forest Train-classes (MJTRain*) now store the used datasets
444 in the output file
445
446 * the MFMagicCuts have a new option to allow a linear area cut (for
447 special studies)
448
449 * The liniking of the shared object is now done into a file defined
450 by 'mktemp'. This should be a local file system which accelerates
451 liniking a lot.
452
453 * The code has been prepared for compilation with root 5.18/00d
454
455 * The MHEnergyEst histogram now shows the distribution of
456 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
457 and (Eest-Emc)/Emc vs Emc.
458
459 * fixed mars (event display) for merpped raw-data and MC data
460
461 * adapted the synatx of sequence files to allow for the new run/file
462 scheme. For more details see class description of MSequence
463
464 ;showplot
465
466 * Added support for tiff files
467
468 * Added support for csv files (tables containing tab number,
469 name and title)
470
471 * Tabs now can have a title which is displayed in the postscript file
472
473 * When multiple file are written at once (e.g. pngs from a display)
474 it is now possible to use the tab name and or tab number in the
475 file name. For details see showplos's help.
476
477 ;merpp
478
479 * Implemented cc file version 2008-02-20/0
480
481 * Implemented cc file version 2008-05-19/0
482
483 * With new options merpping can be restricted (in addition to the
484 run-number) also by telescope and file number.
485 For details see "merpp --help"
486
487 * Implemented raw data format 11 (the most important change, except
488 from plenty of changes in the format definition, is the addition
489 of the file-number in the header) If nobody makes a mistake this
490 format should have the advantage that it is by definition forward
491 compatible, so old programs will be able to read newer formats.
492
493 * Added Pyrometer information to default output (stored in a new Tree
494 Pyrometer, needs a complete new merpp, i.e. new calibration)
495
496 * Merpping (also update) can now be restricted to one single report.
497 For example:
498 If you want to update an old file with Pyrometer information call
499 merpp --only=Pyrometer --update
500
501 ;callisto
502
503 * in the pedestal processing now at least 50 processed events are
504 required for succeeding.
505
506 * the signal and calib files now contain also the sequence information
507
508 * the two MPedestalCam in the calib file now have proper names
509 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
510
511 * Both pedestal cams now contain the number of events processed
512
513 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
514 i.e. for the extraction of the calibration pulses basically the average
515 over all events of the first slice instead of all slices was used.
516 Since pedestal and calibration constants are continously recalculated
517 this only effected the very first events of every sequence.
518
519 * For the extraction of the position of the maximum sample now the
520 extraction range is set automatically to the extraction window,
521 before the whole accessible range was used.
522
523 * If the number of samples in the events and the number of samples
524 in the run-header disagrees now an error is raised (this can
525 happen in not well simulated Monte Carlo files)
526
527 * In the case of MUX-data pedestal events with the lvl1 trigger flag
528 could survive into the pedestal calculation -- fixed.
529
530 * Tab "TrigPat" added showing the distribution of the trigger pattern
531 as found in the run-files (normalized with the run length)
532
533 * The selection of events from the trigger pattern has been improved.
534 If the trigger pattern is corrupted events won't pass anymore.
535
536 * Added a new command line option --dev-null to suppress output of
537 Y-files (this is useful for test cases)
538
539 * added a new tab "CalPos" showing the arrival time of extracted
540 interleaved calibration events
541
542 ;star
543
544 * the star file now contains also the sequence information
545
546 * Added a new command line option --dev-null to suppress output of
547 I-files (this is useful for test cases)
548
549 * Tab "Rate" added showing the distribution of the trigger pattern
550 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
551 the Y-files (normalized with the run length)
552
553 * The effective on-time calculation doesn't use events with only
554 sum-trigger anymore
555
556 * The data in the MHWeather tab has been reorganized. The never
557 working solar radiation has been removed and the data from
558 the pyrometer (cloudiness, air and sky temperature) is
559 displayed in addition.
560
561 ;ganymed/sponde
562
563 * Now data points are even shown correctly if they have error bars larger
564 than one sigma. Points with null or negative significances are omitted.
565
566 * DrawNicePlot now allows to set a projection range
567
568 * Updates pointing models. One is applied after the implementation
569 of the new LUTS in August, the other one is applied after the
570 next major change of the pointing model in October. Note that
571 these models are preliminary and give wrong results below Zd=65deg
572
573 ;sponde
574
575 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
576
577 * a new option "--force-runtime" is available. In case of very short
578 datasets (for light-curves) which are in the order of a few
579 minutes the calculated effective on-time is not very acurate because
580 it is quantizised in the order of a minute. Therefore you can switch
581 to using the real run-time instead (remakrt: this ignores any
582 dead-time!)
583
584 * a more analytical way is used to "fill" Monte Carlos into regions
585 of impact parameters which have not been simulated because the
586 trigger efficiency is assumed to be 0.
587
588 * estimated sensitivity curves for hi and lo zenith angles are shown
589 scaled to the correct observation time and collection area
590
591 * the Monte Carlo events after cuts are now written to the output file
592 if an output file given
593
594
595
596 *** Version 2.0 (2007/09/03)
597
598 - database: the position used for the pulse pos check was missing
599 in the callisto output and could thus not be filled into the DB.
600 Also the old values seemed not exactly the PulsePos used for
601 teh check.
602
603 - general: Resource file now allow an Include-Resource, i.e. you can
604 read a resource file with default settings, include it in your
605 resource file and overwrite the settings in your file. More than
606 one include file is allowed. Inclusions can be iterative.
607 Include: mydefaults.rc yourdefaults.rc
608 The resources in the first file have higher priority than the
609 second file.
610
611 - general: Now the output files (calib*.root, etc) also contain the
612 resource file (to check it open it in the TBrowser and choose Print()
613 from the context menu)
614
615 - general: Dataset files now allow to overwrite the default path
616 to search for sequence and data files. Note, that the program
617 option and individual resources will overwrite it. For example:
618 SequencePath: /magic/montecarlo/sequences
619 DataPath: /magic/montecarlo/star
620
621 - general: Fixed a problem with variables in MDataPhrase. It seems
622 that only optimdisp (didn't work) was effected.
623
624 - general: Some improvements to the optim and train processing. For
625 example the ststud window now got a proper title.
626
627 - general: The "Status Display: " was removed from the window title
628 within an Eventloop.
629
630 - general: added a new flexible histogram-class (MHn) which can be used
631 for example in testing after optimizations or training to produce
632 user defined histograms.
633
634 - general: The Random Forest now allows attaching an evaluation
635 function which is applied to its output. This allows to train
636 on whatever you like (eg. train on log10(energy), but return
637 energy)
638
639 - general: The Random Forest training of energy (trainenergy.c) and
640 disp (traindisp.C) has been improved by more graphical output to
641 judge the result.
642
643 - general: The training of energy (trainenergy.C) has been improved
644 a lot by training on a different quantity than energy. It gives
645 a result which is highly independant of the source spectrum
646 and shows lower bias than all other options.
647
648 - general: Dataset files are allowed to contain collections of
649 datasets. For more details see the class reference of MDataSet.
650
651 - general: The default WobbleMode in a datset file now (if not
652 overwritten) is "auto", i.e. wobble mode is set if the dataset
653 doesn't contain off-sequences.
654
655 - merpp: Merpp can read file format version 9 now. Please realize
656 that for file format version 9 the extraction range is different
657 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
658 the first and last 15 slices have been removed from all MUX data.
659
660 - mars: Similar to writing movies you can now select events which
661 should be displayed in your display. Therefore add the following
662 lines to your mars.rc:
663 MFEvtNumber.FileName: ganymed00223552.root
664 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
665 The input file can be a ganymed-file after (ganymed*.root) or
666 before (ganymed*-summary.root) file. For example to select all events
667 from your on sample after cuts (excluding the ThetaSq cut) use
668 MFEvtNumber.Selector: DataType.fVal>0.5
669 To show all events from your on-sample after quality cuts
670 use the summary file instead.
671
672 - mars: new ways to call mars are implemented. Instead
673 of calling
674 mars filename.root
675 you can now also use
676 mars sequence.txt
677 or
678 mars sequence.txt inputpath
679 or replace sequence.txt by the sequence number if the default
680 sequence file should be used.
681
682 - mars: The default size has been increased
683
684 - mars: There are two new heckboxes which allow to switch off
685 the calculated image parameters
686
687 - callisto: was broken for MCs... fixed.
688
689 - callisto: improved calculation of spline coefficients a lot. This
690 leads to a further improvement of the event rate calibrating MUX
691 data of about 15% (175evt/s instead of 150evt/s)
692
693 - callisto: finally the raw data we read is now real 16bit (with
694 10bit precision) for MUX data and not a stripped 8bit number
695 anymore. Due to scaling of the numbers (without precision loss
696 into an [0-256[ range, the final numbers for pedestal, pedestalrms
697 and extacted signal don't change. However, at all places where
698 raw data is directly accessed (eg. saturation and variation
699 limits in the signal- and pedestal-extraction) the numbers
700 refer still to the data's 16bit range.
701
702 - callisto: The maximum arrival time difference used in the bad
703 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
704 for both, old FADC and MUX-FADC, data.
705
706 - callisto: Be aware that callisto is now calibrating the arrival time
707 in nanoseconds rather than time slices. Also all following tasks
708 have been changed to assume ns units now. If you star data
709 calibrated with an older version it might be necessary to adapt
710 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
711 to obtain optimal results. The plot in the PulsePos tab
712 will now be in ns, too. This might also mean that the Muon
713 analysis in star might not work as perfect as expected as long
714 as old files read in.
715
716 - callisto: The calibration constants of earlier updates got lost
717 somehow. All constants have been updated.
718
719 - star: The PSF is now determined from the profile of the ArcWidth
720 instead of arcwidth/radius. The old way gave to much weight
721 to the bins with low statistics. The reference lines have been
722 updated.
723
724 - star: For speed reasons events suitable for the muon analysis
725 are now also preselected by fConcCOG<0.1 which seems to be a very
726 good preselector for muons.
727
728 - star: is now calculating a new timing parameter the Slope along
729 the major and minor axis of the shower. Therefore a numerical
730 solution of a line-fit is used. To use MHillasExt.fSlopeLong
731 and MHillasExt.fSlopeTrans don't forget to multiply it with
732 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
733
734 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
735 have been removed from MNewImagePar. They have never been good for
736 anything.
737
738 - star: Implemented a new recursive algorithm which is supposed to be
739 faster. Also implemented new cleaning oiptions, which are:
740 + CleanLevel0:
741 The cleaning level above single core pixels can be kept
742 + KeepIsolatedPixels:
743 Define whether single core pixels should be kept
744 + TimeLevel1:
745 The coincidence window in nanoseconds to single used neighbors
746 + TimeLevel2:
747 The coincidence window in nanoseconds to two used neighbors
748 + PostCleanType:
749 MOde in which a time dependent post cleaning should be applied
750 0: No post cleaning
751 1: Require for each used pixels at least one used neighbor
752 within a time-window of CleanLevel1
753 2: Require for each used pixels at least two used neighbor
754 within a time-window of CleanLevel2
755 3: Require first two and second one used neighbor
756 within a time-window of CleanLevel1 and fCleanLevel2
757 respectively
758 + RecoverIsolatedPixels:
759 - recoveres isolated core pixels if they have a used neighbor
760
761 - mars/star: The new default cleaning is:
762 + CleanLevel1: 6.0
763 + CleanLevel2: 3.0
764 + CleanTime1: 1.75
765 + CleanTime2: 1.75
766 + PostCleanType: 3
767
768 - star/ganymed: The old spark-cuts have been replaced by new ones.
769 These new spark cuts have been cross checked with the sequences
770 84720 (before splitter), 101041 (after splitter) and 223539 (new
771 FADCs). In all cases they seperate pretty well, but of course not
772 perfect. Monte Carlos have suggested to tighten the cuts a little
773 bit further at low sizes. This has been done.
774
775 - ganymed: IMPORTANT - The spark cuts have been changed to match
776 all available data more or less well. This might mean that for
777 YOUR data there are still sparks visible.
778 Whenever you do an analysis you have to make sure that NO sparks
779 survive your cuts!
780
781 - ganymed: The old hadronness and size cuts have gotten new indices
782 (10, 11). The old indices 8 and 9 now mean an additional condition
783 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
784 If you want to switch off this cut just move the line far away enough,
785 e.g. by setting c[9] to -500. Please update your ganymed.rc files
786 accordingly!
787 The unit of c[9] is deg. It is the dist at which your cut will
788 cross the slope==0. The unit of the slope is ns/deg. So if
789 you readin files calibrated with an older Mars-version you
790 have to adapt the default value for c[9] to the FADCs:
791 - Multiply by two for the MUX FADCs (run number > 200.000)
792 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
793 - Multiply by 42 for the meaning of life (run number = 200.000)
794
795 - ganymed: The old Cut0 is now called CutQ and is calculated before
796 the source position is caluclated. If you need a quality cut
797 including source dependant data (be very carefull with this!)
798 you have to use Cut0 instead.
799
800 - ganymed: now properly supports three off regions in wobble mode.
801 It will be the default from now on in ganymed_wobble.rc. To change
802 the number of off-regions use
803 NumOffSourcePositions: 1
804 in your ganymed.rc. Also by default no off-theta cut will be done
805 anymore so that you will get a background level higher than the
806 signal level in your ThetaSq plot for ThetaSq>0.2.
807 Due to this be carefull changing the scaling mode away from
808 "None". You will underestimate your signal if your scale interval
809 is not properly set.
810 (Rem: ThetaSqN is no longer needed)
811
812 - ganymed: is now storing the events of all (on- and off-)
813 source positions even in the case of more than one off-source
814 position. This should allow sponde to work properly and the
815 energy estimation is done correctly in all cases (without any
816 "nearest position" trick)
817
818 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
819 with a real pointing model for the starguider is done, calibrated
820 with more than thousand tpoints taken from this date on.
821
822 - ganymed: was broken for Wobble-MCs... fixed.
823
824 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
825 has changed. Note that your old ganymed.rc will be incompatible
826 with the new algorithms! Please check the ganymed.rc files and
827 the class description of MFMagicCuts for more information.
828 It is recommended at the moment to use identical Disp-Parametrizations
829 for on/off- and wobble-mode. If cuts are optimized only
830 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
831 should be optimized. All other values should be kept as they are.
832 If you want to do an anylsis without timing a parameters, you can
833 switch off the timing cuts by seeting parameter 7 to a very small
834 value (eg. -99). To remove the slope parameter from the disp
835 paremtrization set parameter 8 to 0.
836
837 - ganymed: The distribution of observation time versus zenith
838 angle is now shown for off- AND on-data.
839
840 - ganymed: The contents of the source position plot are no longer
841 averaged, thus a lot of (fake) events between the two wobble
842 positions have disappeared.
843
844 - ganymed: There is a new tab "CutT" it contains the VsSize plots
845 with the CutT, whihc is defined in ganymed.rc, applied. It
846 is resonable to use your theta-cut for it, to see if there is
847 something strange (sparks!) in your signal-region.
848
849 - ganymed: To choose a dataset from a collection in a dataset file
850 use the new command line option "--dataset=12345"
851
852 - optim, sponde: should now properly support three off-regions.
853 Just produce your ganymed summary files with three off-regions.
854 optim and sponde will automatically get all off events from
855 all off-regions from this file. Please do not forget to
856 set the scaling in optimwobble.C properly:
857 fit.SetScaleUser(1./3);
858 it is not yet read in automatically (will follow soon).
859 In the case of fixed Scale you can also use
860 cuts.SetThetaCut(MFMagicCuts::kOn);
861 no off-cut needed.
862 Be carefull in case of three off-regions when switching on
863 scale mode. Make sure that the scale interval is set correctly.
864
865 - sponde: sponde.rc and sponde_onoff.rc are now idetical
866
867 - sponde: the resouce files have been rewritten with a lot of
868 comments and a well working parametrization for an energy estimator
869
870 - sponde: In the estimated energy versus monte carlo energy plot the
871 contents where exchanged.... fixed.
872
873 - sponde: the so called "accurate"-mode has been removed. It didn't
874 give any improvement in accuracy, only decreased execution speed.
875
876 - sponde: the so called "simple"-mode has been removed. It didn't
877 give any improvement in simple.
878
879 - sponde: the so called "refill"-mode has been removed. It was anyhow
880 not implemented.
881
882 - sponde: now checks whether the theta distribution of your on-data
883 and the theta-distribution of your Monte Carlo sample (after
884 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
885 sample is incomplete) execution is stopped. Execution can be forced
886 using the new option --force-theta. Use this option with care!
887
888 - sponde: Proper collection areas can now be constructed also from
889 Monte Carlo samples generated with different maximum impact
890 parameters. Note that in previous version you neither got
891 a warning or failure, nor was there any obvious sign that the
892 collection area was overestimated due to usage of files with
893 different maximum impact parameters.
894
895 - sponde: If MC files with different lower energy limits are used
896 the primary MC spectrum is artificially completed down to the
897 lowest energy used at all. WARNING: that this gives correct
898 collection areas ONLY if none of the events in this region would
899 survive your cuts at all.
900
901 - sponde: the output file now contains more information about
902 the spectrum (eg. the full 2D collection area histogram).
903 Note, that this information can only be written to the file
904 if it is stored automatically via command line argument.
905 If you only store the status display from within the display
906 the information is lost.
907
908 - sponde: added a new tab "Disp". It shows the residual of the disp
909 (Disp-Dist) versus several parameters and it is meant to judge the
910 quality of the disp estimator. In the ideal case the residual is zero
911 and doesn't depend on any variable. The tab is displayed after
912 CutQ and Cut0.
913
914 - sponde: added a new tab "Energy". It shows the residual of the
915 energy (lg(estimated energy)-lg(monte carlo energy)) versus
916 several parameters and it is meant to judge the quality of the
917 energy estimator. In the ideal case the residual is zero
918 and doesn't depend on any variable. In reality even a good estimator
919 can show residuals versus Monte Carlo energy. The tab is displayed
920 after all cuts.
921
922 - sponde: added a new tab "EventDist" showing the unweighted real
923 absolute number of events of your sample after cuts. This tells
924 you how many events with this energy you had in your MC files.
925 The same information you get from the error bars of the weighted
926 histograms, but this is less intuitive.
927
928 - sponde: The spectrum plots now show the crab- and 1553-spectrum
929 for comparison. It is not meant to show these curves in
930 publications, they are only for production.
931
932 - sponde: The OriginalMC tree with the events produced by corsika
933 is now processed only once
934
935 - sponde: Finally fixed most annoying bug, which has effected the
936 last bin of the collection area. It was the problem that binnings
937 of root histograms are from 1 to n (included) but there was a C-like
938 loop in sponde from 0 to n (excluded). Now the loop also includes
939 correctly under- and overflow-bins. The worse thing with this is,
940 that for the events in the highest bin not only the bin-content
941 was wrong, but also the weights applied to these events, which could
942 in pricipal effect also other parts of the distribution (eg. due
943 to energy estimation). Fortunately it effected only a few events
944 in most cases.
945
946
947
948 *** Version 1.2 (2007/05/14)
949
950 - database: The database now has two new values Unsuitable50 and
951 Unsuitable01. They express the number of pixels which are
952 unsuitable for more than 50%, respectively more than 1%, of
953 all calibrated event. It is a more accurate number than the
954 previously used numbers, because they only take the first
955 calibration (ignoring the interleaved calibrations) into account.
956
957 - database: The database now has two other new values UnsuitableMax and
958 DeadMax. They express the maximum number of pixels which were
959 unsuitable, respectively dead, during the sequence. Because
960 of high pedestal rms (cars passing) a few events with very high
961 numbers of unsuitable pixels can happen. Not to suffer from this
962 effect we don't take the highest 0.1% of the numbers into account.
963
964 - general: fixed a bug which caused callisto and star to stop working
965 properly because the callisto output was currupted
966
967 - general: a script called scripts/makemovie has been added which
968 simplified the process of producing several movies from a single
969 sequence with different setup.
970
971 - callisto: Some more code cleanup. Started to remove old obsolete
972 code from cvs.
973
974 - callisto: The extraction of the pedestal with the extractor was
975 not random. It seems that extracting at one position is still biased
976 (for example in the first or last slices we could still suffer from
977 switching noise) Now it is completely random.
978
979 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
980 pedestal files) individual pixels could be skipped due to high
981 variations. This was already the case for the pedestal extraction
982 from the lo-gains since the beginning and properly handled
983 there, but was introduced in the extraction from the pedestal files
984 a while ago. To calculate the average value it was still divided
985 by the number of events procesed not by the number of summands
986 really summed. This let to a pedestal which was a tiny amount too
987 small (for a few piels in the order of 0.1%). This led to an slightly
988 positive offset of the randomly extracted pedestal for a few pixels.
989 I doubt that this has a big effect on the result, because the effect
990 on the individual numbers is quite small. Due to this it is suggested
991 that you rerun your calibration to make sure you are without any
992 avoidable bias.
993
994 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
995 the median rms of the absolute arrival time and expressed in significance
996 levels. This replaces the old meaning of an abolute upper limit. An
997 absolute upper limit doesn't make much sense, because in our data
998 all arrival times are shifted at the same time (in fact it might be
999 a shift of the artificial trigger w.r.t. to the light flash).
1000
1001 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1002 of the number of unsuitable pixels over the whole sequence. This
1003 is usefull mainly to judge if an intermediate calibration had
1004 problems.
1005
1006 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1007 of the number of dead pixels over the whole sequence. Dead pixels
1008 in this context are unmapped pixels, i.e. pixels which could not
1009 be interpolated, and thus are ignored in the further analysis.
1010
1011 - callisto: It is now possible to use the position of the maximum
1012 of the spline as arrival time instead of the leading edge even
1013 when using the integral for the signal. Therefor set the extraction
1014 type to kIntegralRel ("IntegralRelative") and the relative height
1015 ("HeightTm") to -1:
1016 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1017 MJPedestalC1.ExtractSignal.HeightTm: -1
1018
1019
1020
1021
1022 *** Version 1.1 (2007/04/27)
1023
1024 - general: The new class MGeomCamDwarf contains the camera geometry
1025 for our prefered Dwarf camera and can be used to create general
1026 geometries of roundish or hexagonal cameras.
1027
1028 - mars: The default cleaning is now abolute 8.5/4.0.
1029
1030 - mars: The resource file mars.rc now contains examples for MUX data
1031
1032 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1033 data containing only 10-bit information is still cooked down to
1034 8-bit, by cutting away the lowest 8-bit.
1035
1036 - merpp: When reading raw data the data is now stored in a single
1037 array. The lo-gain array is obsolete. The interface stays the same.
1038
1039 - callisto: To process the new MUX data use the resource file
1040 callisto_mux.rc
1041
1042 - callisto: The -root and -raw options to read merpped raw data have
1043 been removed
1044
1045 - callisto: If the -mc option is given the sequence-name can now be
1046 replaced by the MC sequence number
1047
1048 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1049 -mc option can now be omitted
1050
1051 - callisto: Started further simplification by removing obsolete
1052 dependancies on MCalibIntensity*Cams.
1053
1054 - callisto: removed unsused intensity calibration from MJCalibration
1055 for further simplification
1056
1057 - callisto: for simplification removed references to
1058 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1059 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1060 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1061 (this should at minimum change nothing at all, and at maximum
1062 improve thing if these containers where somewhere not handled
1063 properly)
1064
1065 - callisto: Added the option to write an event movie. Please use
1066 this option with care (huge files) but exessively to understand
1067 our events. For further documentation please refer to the
1068 IACT wiki
1069 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1070
1071 - callisto: Improved binning for the pulse position check histogram
1072
1073 - callisto: The code calculating the pulse position checknow takes
1074 the pedestal into account
1075
1076 - callisto: The arrival time is now stored with full precision this
1077 helps to get rid of artefacts in histograms. For the signal this
1078 is not necessray because it is displayed in log-scale anyhow
1079
1080 - callisto: Fixed a problem with internal exclusions. Pixels which
1081 have once been marked as unsuitable didn't get the necessary
1082 histograms filled anymore to be rechecked with each interleaved
1083 calibration.
1084
1085 - callisto: The relative arrival time resolution (the rms of the
1086 relative arrival time offset) is now checked against its
1087 median and the median deviation, instead of the average
1088 plus an absolute offset.
1089
1090 - callisto: The relative arrival time offset is now calculated
1091 w.r.t. its median not w.r.t. to an artificial reference pixel.
1092
1093 - callisto: The relative time calibration now marks pixels with
1094 outlaying offset as unsuitable
1095
1096 - callisto: The interleaved relative time calibration has been switched
1097 on. The advantage is that pixels which are marked as outliers
1098 now can recover. An improvement over time is not expected, because
1099 the relative time calibration seems stable.
1100
1101 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1102 option can now be omitted.
1103
1104 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1105 or the option "-mc" is specified as default the monte carlo datacenter
1106 paths (/magic/montecarlo/...) are used if not overwritten in the
1107 dataset file.
1108
1109 - ganymed: The output files now contain run- and event-number for all
1110 events, accessible as RunNumber.fVal and EvtNumber.fVal
1111
1112 - ganymed: Added a plot showing the source position in the camera also
1113 for wobble mode
1114
1115 - ganymed: In addition to the existing task which can be setup to
1116 be executed after Cut1 a final task called "EstimateEnergy"
1117 has been added, executed before writing the final output
1118 (ganymed00000000.root). The task setup in all three cases
1119 can be choosen individually. (For all three(!) cases you
1120 can for example choose MRanForestCalc. For examples see all
1121 sponde*.rc and all ganymed*rc)
1122
1123 - ganymed: If a container "MEstimatedEnergy" is found in the
1124 parameter list (eg. because it was setup by MEstimateEnergy)
1125 it will be written to the output file.
1126
1127
1128
1129 *** Version 1.0 (2007/02/16)
1130
1131 - database: Website to plot values from the database has been added.
1132
1133 - database: The rate of spark events as found by star is now kept
1134 and the rate after cleaning is now with spark events subtracted
1135
1136 - general: The changes to the interpretation of phrases lead to
1137 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1138
1139 - general: Added example files how you can create your own calendar
1140 (eg. as christmas present) with Mars. Just run
1141 root macros/tutorials/calendar.C
1142
1143 - general: Added a possibility to display grouped data in the plotdb.C
1144 macro (and similar macros). This allows to plot hourly, nightly,
1145 weekly, monthly and yearly averages.
1146 For more details see the plotall function of the macro
1147
1148 - general: fixed the error display of the camera display. It showed
1149 wrong results.
1150
1151 - general: fixed a memory leak when reading many MStatusDisplays
1152
1153 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1154 between a spherical and a parabolic mirror
1155
1156 - callisto: We have a new pulse position check which takes the properties
1157 of the extractor automatically into account. So no need to set
1158 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1159 left is done. If possible the lo-gain extraction start and hi-gain
1160 extraction end is changed accordingly. If no proper extraction range
1161 can be set (hi-gain too much to the left) an error is raised.
1162
1163 - callisto: New swapped pixels have been found and corrected
1164
1165 - callisto: Redone the signal extraction this includes:
1166 + Unified the algorithms to extract the pedestal for all pedestal
1167 extractions done
1168 + Unification of hi- and lo-gain into one array
1169 + Unification of hi- and lo-gain extraction for Spline and
1170 Digital Filter (means now exactly the same algorithm is used,
1171 not a copy-and-pasted one)
1172 + Store pedestal subtracted data in a common place
1173 + Improved extraction algorithms. If the algorithms search a
1174 maximum but don't find one they don't return the maximum anymore
1175 + Improved the extraction such that a information for signal
1176 and time which is consistent is returned
1177 + replaced the numerical spline with a (not slower) analytical
1178 solution
1179 + Lowered the saturation limit from 250 to 245 to make sure that
1180 we are far away in all pixels from problems with the clock-noise
1181 + The start of the lo-gain extraction is calculated from the hi-gain
1182 arrival time. In case of saturation an estimation is used.
1183 + the hi-gain window was extended to slice 16. This allows extraction
1184 of very late pulses in single pixels or of huge hadron showers.
1185 + Now uses the lo-gain extraction range for pedestal extraction,
1186 not the hi-gain range in the lo-gain
1187
1188 - callisto: New hi-/lo-gain calibration constants have been produced
1189 for all periods from the statistic of the whole period. They are
1190 now used automatically depending on the periods. The old constants
1191 where deviation in avarega about 2%-3%. The constants are very
1192 stable from period to period (<<1%) except for exchanged channels.
1193 In a few cases the constants used so far were off by 1%-2% (maybe
1194 temperature effects?)
1195
1196 - callisto: To gain obsolete space we do not write the
1197 MPedestalFundamental anymore. Also calibration and bad pixel
1198 treatment is not done for it anymore because it has never been used.
1199
1200 - callisto: Fixed a bug in the seuqence handling which caused the
1201 light condition to be ignored
1202
1203 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1204 basically the same as "Cleaned" but the distribution devided into
1205 the events fullfilling a spark cut or being rejected by it.
1206 This cut can be changed from star.rc (see example inside) by
1207 the "SparkCut" directive
1208
1209 - star: Star displays now the average individual pixel-rate (IPR) versus
1210 time and the average discriminator threshold (DT) of all pixels.
1211
1212 - optim: fixed a problem with the optim-macros which was due to a bug
1213 in the new phrase parsing
1214
1215 - ganymed: To get a nice FalseSource plot (instead of the all-information
1216 debug plot displayed as a standard plot) use the context menu
1217 somewhere between the two upper plots, click on "DrawNicePlot"
1218 and enjoy the result. (It is the same context menu which contains
1219 the other options)
1220 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1221
1222 - ganymed/optim/train: The cut program, trainings- and optimization
1223 macros could run with less files found than expected from the
1224 sequence-files. No the execution is stopped in this case.
1225
1226 - ganymed: now stores the dataset in the output file with all information
1227 contained (as sequence number, sequence path, data path) so that the
1228 used dataset file can be recreated complete from the output
1229
1230 - sponde: now also allows the uasge of random forest
1231
1232 - sponde: added a plot showing the cut efficiency
1233
1234 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1235 errors (eg. effecting the collection area) because the errors of the
1236 two histograms were swapped in the calculation, which makes a difference
1237 in the case the histograms contains weighted events. Aditionally the
1238 totalarea was incorrectly taken into account, which results in too small
1239 errors, which makes a difference at low statistics were the errors
1240 or the collection area dominate.
1241
1242
1243
1244 *** Version 0.10.3 (2006/10/23)
1245
1246 - database: Implemented ObservationMode flag in websites.
1247
1248 - database: For sequences there is now also the stoptime available on the
1249 websites.
1250
1251 - database: Removed ManuallyChanged flag from sequence-info websites,
1252 as it is not needed anymore with the new sequence building algorithm.
1253
1254 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1255 Class for calculation of confidence intervals (upper limits).
1256 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1257 Please read the class instruction of TRolke for more information.
1258
1259 - general: The programs now return 0xfe if the requested resource file
1260 doesn't exist.
1261
1262 - general: Errors comming from root itself are now not output to
1263 stderr anymore but to our default (colored) log-stream.
1264
1265 - general: Changed the interface to TFormula such that now everything
1266 is parsed by TFormula, which should allow to use phrases even
1267 without paranthesis correctly parsed.
1268
1269 - callisto: replaced the AdHoc number of effective integration slices
1270 in the digital filter by an average of the correct number, averaged
1271 over all possible set of weights. This also gives correct numbers
1272 for the lo-gains which were totally wrong before.
1273
1274 - callisto: drastically reduced memory consumption by not storing
1275 all intermediate calibration results in memory anymore (we might
1276 write them into a file in the future)
1277
1278 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1279 debug plot displayed as a standard plot) use the context menu
1280 somewhere between the two upper plots, click on "DrawNicePlot"
1281 and enjoy the result. (It is the same context menu which contains
1282 the "DrawAll" option)
1283 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1284
1285
1286
1287 *** Version 0.10.2 (2006/10/15)
1288
1289 - general: changed the building of the sequence files such, that
1290 the source-/project name in case of wobble-sources is not the
1291 source/project of the first data run anymore but the new generalized
1292 wobble source/project
1293
1294 - general: Added some functions to MAstro to calculate sun and
1295 moon properties
1296
1297 - general: Added two new macros (starvisday.C and starvisyear.C)
1298 which allow to plot the visibility of several stars in one day
1299 or of one star along one year
1300
1301
1302
1303 *** Version 0.10.1 (2006/10/11)
1304
1305 - general: HTML logging output was distorted... fixed.
1306
1307 - general: Changed the writing of the sequencefiles such that only
1308 as many pedestal files as giving at least 1000 pedestal events which
1309 are nearby the first calibration run are used as pedestal runs
1310
1311 - sponde: In the calculation of the collection area(s) and the
1312 distribution for MOnte Carlo and estimated energy the error
1313 calculation was wrong because root didn't take the errors
1314 properly into account... fixed.
1315
1316
1317
1318 *** Version 0.10 (2006/10/10)
1319
1320 - general: all executables now check consistency of the root version
1321 installed with the root version used for compilation. The return
1322 code in this case is 255.
1323
1324 - general: The algorithm to build seqeunces has been redesigned
1325 completly. It is now more flexible in terms of a resource file
1326 resources/sequences.rc which can be used to partly overwrite
1327 the default algorithm and defined the important part of the
1328 algorithm. It also takes correctly into account several ways
1329 of taking wobble-data. Currently the new algorithm doesn't take
1330 the number of pedestal events anymore into account (so a sequence
1331 could have much less than 1000 pedestal events and data runs are
1332 no-more used instead)
1333
1334 - general: a lot of small changes to make the code compatible with
1335 root 5.12/00 and gcc 4.1
1336
1337 - general: Fixed some warnings thrown if more warnings are switched
1338 on in the compiler
1339
1340 - general: Added a function to MMath which returns the Median of
1341 the distribution abs(y[i]-median) but at 68:32 division instead
1342 of 50:50, which is somehow the median counterpart of the rms.
1343
1344 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1345 even if they are compressed with gzip (recommended compression
1346 is with "-1")
1347
1348 - showplot:
1349 + batch mode creation of image files now works with root 5.12/00
1350 + added support for writing bmp (though it never produces
1351 bmp which can be read by programs like xv or gimp)
1352 + added support for xml
1353 + added new option to start the display with a different size, by
1354 --display-width=nnn or --display-height=nnn
1355 + added options to define the canvas size when the display is started
1356 --canvas-width=nnn or --canvas-height=nnn
1357 the option can also be used for batch-mode conversion
1358 + added an option which automatically fits the display size to the
1359 desktop-size: --auto-size
1360
1361 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1362
1363 - merpp: allow the reports to have 1000ms due to a bug in the camera
1364 program.
1365
1366 - callisto: New swapped pixels have been found and corrected. For
1367 details see MRawRunHeader::FixAssignment()
1368
1369 - callisto: Callisto now raises an error if one of the input files could
1370 not be opened.
1371
1372 - callisto: In some rare cases it could happen that in the signal
1373 extraction of the digital filter the extractor returned nonsense
1374 results due a wrong initializion of a variable (this happens in
1375 cases in which the extracted signal is exactly zero or the
1376 digital filter couldn't slide because of a too small extraction
1377 window, which could happen in the lo-gain extraction)
1378
1379 - callisto: The lo-gains have been marked as valid in some cases
1380 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1381 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1382 smaller than the number of slices (fLoGainWindowSize) needed
1383 by the lo-gain extractor
1384
1385 - callisto: Updated absolute calibration constants (muon calibration)
1386
1387 - callisto: fixed a bug which caused the hi-gain saturation not
1388 to be handled properly in the spline (the position of the
1389 saturation was calculated incorrectly)
1390
1391 - callisto: fixed a bug which gave weird results if hi- _and_
1392 lo-gain could not be extracted properly. In some cases hi-
1393 and lo-gain have not been extracted at all and the random result
1394 got calibrated. In other cases the hi-gain was saturating and the
1395 lo-gain has not been extracted. For this a completly arbitraty
1396 scale factor was applied to the result from extracting the
1397 charge of the saturating hi-gain.
1398
1399 - callisto: improves handling of extracted signal if lo- and/or
1400 hi-gain could not be extracted properly. If no appropriate
1401 calibration of either the signal or the arrival time is possible
1402 the pixel is now markes as unsuitable instead of estimated.
1403
1404 - callisto: Fixed a problem in the spline extraction which gave
1405 weird results if the signal was extracted from the first (and
1406 highest) slice (as a workaround extraction from the first
1407 slice has been forbidden)
1408
1409 - callisto: Fixed a bug regarding the use of the QE which doesn't
1410 effect the result because the default is used anyhow.
1411 (The bug was there since 14/07/2005)
1412
1413 - callisto: Changed the default for fgLoGainStartShift to -2.4
1414
1415 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1416 factors to be always 10 for all pixels as soon as the first
1417 calibration update has happend.
1418
1419 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1420 was off by more than one slice (which gives wrong values for
1421 pixels which have saturated the hi-gain) This was a problem
1422 mainly for timing studies, not so much for the automatic standard
1423 analysis. Also the values for the Spline have been changed slightly:
1424 + Digital Filter from 1.70 to 0.95
1425 + Spline from 1.39 to 1.30
1426 The numbers were sorted out by an extensive test in the
1427 test-database.
1428
1429 - callisto: Removed the tab showing the average calibrated arrival
1430 time. It never gave useful information.
1431
1432 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1433 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1434 and both were extracted because the hi-gain was above the
1435 LoGainSwitch.
1436
1437 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1438 lo-gain pulse position (after application of LoGainOffset, which
1439 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1440 have saturated and both were extracted because the hi-gain was above
1441 the LoGainSwitch.
1442
1443 - callisto: After extensive tests a new threshold level for determination
1444 of the pulse position has been found at 50phe. This is due to the
1445 fact that for lower pulses the arrival time changes its average
1446 behaviour dramatically. It tends to the average of the extraction
1447 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1448
1449 - callisto: Added two more plots to the calibration part. The average
1450 extracted signal and the average extracted arrival time as
1451 extracted by the signal extractor (This can help debugging problems
1452 because it doesn't involve a fit)
1453
1454 - star: changed the fit for the effective on time such that initial
1455 values are calculated automatically now instead of using build
1456 in values. This makes the fit more indepedant of the underlaying
1457 rates. With a test of ~350 sequences in the test database it could
1458 be shown that the new fit gives the same result +/-1sek.
1459 The highest deviation was +5s the lowest -10s. You can now control
1460 the bahaviour with two resource values:
1461 MHEffectiveOnTime.FistBin: 3
1462 MHEffectiveOnTime.NumEvents: 12000
1463 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1464 from the resulting gamma candidates
1465
1466 - star: The Center histogram in MHHillas is now by default displayed
1467 with the colz draw-option
1468
1469 - ganymed: now produces valid error codes if failed
1470
1471 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1472 with the option "hadronness" instead of "area" or "both" if
1473 you want to use both cuts. The hadronness cut includes a fixed
1474 cut in hadronness (index 8) and a fixed cut in size (index 9).
1475
1476 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1477 the M3Long of the anti source to be not properly evaluated
1478 (actually is was evaluated as a unique random number) in case
1479 of optimization with anti-theta cut switched on. This might have
1480 lead to improper, but not necessarily wrong, optimization results.
1481
1482 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1483 how to use random forest
1484
1485 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1486 ganymed_onoff.rc. Seems to be unintentional that they were different.
1487
1488 - sponde: Since the introduction of the possibility to define a
1489 normalization energy instead of using the integral the default
1490 was not using the integral anymore but a normalization energy of
1491 1GeV. It is now the integral again.
1492
1493 - sponde: Fixed a problem in the weighting which did not allow
1494 a MC slope of -1.
1495
1496
1497
1498 *** Version 0.9.6 (2006/05/24)
1499
1500 - general: changed the binning of the azimuthal profile of the camera
1501 such that it is aligned with the 60deg boundaries.
1502
1503 - merpp: better handling of problems with the TH, TD part of the
1504 CC-REPORT for files older than 200507190 and 200412210
1505 respectively
1506
1507 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1508
1509 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1510
1511 - callisto: if an arrival time is extracted outside the fadc range is
1512 was set to the boundary before. Now a random number is assigned
1513 instead to avoid unfortunate coincidences of arrival times just
1514 by this arbitrary value.
1515
1516 - callisto: added a new option to callisto.rc which allows
1517 to set the maximum arrival time difference allowed for the
1518 badpixel algorithm to determin whether a pixels belongs to a shower:
1519 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1520
1521 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1522 to 0.9 as suggested by Stefan due to a recent study on the fraction
1523 of pixels surviving the image cleaning
1524
1525 - callisto: switched off error in case of "pulse is too much to the left"
1526
1527 - callisto: The extraction window is not adapted anymore. This means that
1528 the pulse is extracted from the full range. The draw-back is that the
1529 background (pedestal) will become slightly higher. Switching on/off
1530 the PulsePosCheck in the callisto.rc only effects filling the
1531 histograms.
1532 WARNING: If the pulse is too much to the left data is calibrated!
1533 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1534 in the database to make sure that your data is valid!
1535
1536 - star: Show also the number of stars correlated correctly by the
1537 starguider
1538
1539 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1540 than one off-source region in wobble-mode. To use it add the following to
1541 your ganymed_wobble.rc:
1542 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1543 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1544 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1545 + Cut1.ThetaCut: None
1546 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1547
1548 - ganymed: in the case the latest report is older than a default (currently
1549 one minute) and the current report will be skip the starguider
1550 correction and calibration will be reset. The maximum age can be
1551 setup from ganymed.rc by (minutes):
1552 MPointingDevCalc.MaxAge: 1.5
1553
1554 - ganymed: A first implementation showing all size-bins for the theta-sq
1555 resp. alpha-plots in a single tab automatically
1556
1557
1558
1559 *** Version 0.9.5.1 (2006/05/05)
1560
1561 - general: Added a new option "zdiff" to the Makefile which runs
1562 "cvs diff" as "make diff" would do, but with compression
1563
1564 - general: accelerated MTFillMatrix (used for eample in all training
1565 and optimization macros) by skipping some obsolete calles in the
1566 eventloop the first and second loop could be accelerated by ~20%
1567
1568 - general: Added a missing feature in the MFilterList class which
1569 prevented MFEnergySlope from working correctly in trainenergy.C
1570
1571 - general: Accelerated the random forest training and usage a bit
1572
1573 - merpp: Adapted to new raw data file format version 6
1574
1575 - merpp: fixed a problem with reading the starguider reports
1576 after 6.3.2006
1577
1578 - callisto: At some times six pixels had to be exchanged manually in the
1579 data. If the pixels to be swaped are both not found, an error was raised
1580 and calibration was stopped. Now it is assumed they are intentially not
1581 mapped and the Error has been changed to a Warning.
1582
1583 - star: Added new image cleaning based on the arrival time of the shower.
1584 The new cleaning can be accessed using the parameter "Time" instead of
1585 the the old one (like "Absolute) in the star.rc-file.
1586 Recommended parameters:
1587 + MImgCleanStd.CleanLevel1: 8.2
1588 + MImgCleanStd.CleanLevel2: 5
1589 + MImgCleanStd.CleanRings: 2
1590 + MImgCleanStd.KeepSinglePixels: No
1591
1592 - star: Simplified the calculation of the effective on time. By letting
1593 the fit start in the third bin the result should become more stable.
1594 The fit quality is now ignored for the theta-plot which is not used
1595 in the analysis later. Still better pre-cut which, for example,
1596 remove events triggered by car-light (rate changing on a short
1597 time-scale) are missing.
1598
1599 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1600 for optimization (kWeakSource) which is suggested by the Berlin
1601 people for weak sources.
1602
1603 - macros: plotdb.C:
1604 + if no dataset and no time-interval is given only sequences with
1605 an effective on-time above five minutes are plotted anymore
1606 + added a new tab "RelTime" displaying the relative on-time
1607 (effective on-time divided by the observation time)
1608
1609 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1610 the optimization became a lot faster
1611
1612 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1613 To display them just delete the pads displayed on top.
1614
1615 - ganymed: fixed a bug which could cause strange behaviour in wobble
1616 mode if no starguider information was available due to an incorrect
1617 initialization of the starguider calibration
1618
1619 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1620 be changed from within the plot. It can also be setup from the
1621 resource file using:
1622 + MHDisp.fScaleMin: 0.325
1623 + MHDisp.fScaleMax: 0.475
1624
1625 - ganymed, showplot: Fixed a problem with the fit to the off-data
1626 (HistOff) which could cause a time lag or an inifinite loop.
1627 The bug did not effect the results at all.
1628
1629 - sponde: Added a new tab showing the effective collection area after
1630 trigger (including the software trigger)
1631
1632 - sponde: MMcSpectrumWeight has a new option which allows to define
1633 the scaling factor not by the integral of the events but at
1634 a defined energy:
1635 e.g. MMcSpectrumWeight.NormEnergy: 200
1636
1637 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1638 eventloops the loop could be accelerated by ~20%
1639
1640
1641
1642 *** Version 0.9.5 (2006/03/13)
1643
1644 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1645 and added the standard Disp-parametrization
1646
1647 - macros: added a new macro datacenter/macros/plotstat.C allowing
1648 to plot statistics about the data processing
1649
1650 - macros: added a new macro to plot the muon correction coefficients
1651 versus period (macros/plot/mucal.C)
1652
1653 - showplot: path inflation for ganymed files was broken
1654
1655 - callisto: Fixed an important bug. When the number of saturating pixels
1656 were calculated the bad pixel information already available from the
1657 calibration was ignored. This yields wrong values in case pixels
1658 are broken and saturate all the time or randomly.
1659
1660 - callisto: Updated Muon calibration constants. Spline data now also uses
1661 different values for different periods
1662
1663 - star: The time-evolution shown in the effective on-time plot now displays
1664 the axis range (if there are no holes it should be similar to the
1665 effective on-time)
1666
1667 - star: Added two new image parameters:
1668 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1669 the three pixels next to the center of gravity and the size
1670 + MNewImagePar.fConcCore: The ratio of the signals of all
1671 pixels inside or touching the ellipse and the size
1672
1673 - ganymed: now stops in requested source isn't found in catalog file
1674
1675 - ganymed: Many improvements to the phi-plot in wobble mode:
1676 + with a template the ideal background is displayed
1677 + a possible camera inhomogeneity is taken into account
1678 + the anti theta cut is better supported
1679 + the phi cut is automatically calculated from the theta cut
1680 See the examples in ganymed_wobble.rc for more details.
1681
1682 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1683 times the bin-width instead of the absolute energy
1684
1685 - ganymed: New cuts for on/off and wobble mode
1686
1687 - ganymed: The smearing of the False Source plot has been increased
1688 to 0.06
1689
1690 - ganymed: The starguider calibration can now be changed from the
1691 resource file.
1692 See the examples in ganymed*.rc for more details.
1693
1694 - ganymed: added a new option for on-/off-observations
1695 MJCut.RandomSourcePosition
1696 If switched on the distribution of observation time of the source
1697 position in the camera is calculated from the on-data and randomly
1698 applied with this distrbution to the off-data.
1699
1700 - ganymed: by skipping some obsolete calles in the eventloop the
1701 first and second loop could be accelerated by ~20%
1702
1703 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1704 position in the off-data randomly according to its distribution in the
1705 on-data.
1706
1707
1708
1709 *** Version 0.9.4.3 (2006/02/13)
1710
1711 - general: Fixed a bug in most of the programs which prevented the
1712 compile date in the startup message to be displayed
1713
1714 - general: Simplified program calls. The following abbreviations
1715 are now possible:
1716 showlog callisto 55599
1717 showplot signal 55599
1718 star 55599
1719 callisto 55999
1720 ganymed 2
1721 In this cases the corrsponding root-, log-, sequence- or dataset-
1722 filename is automatically compiled using the default datacenter
1723 paths ("/magic/*")
1724
1725 - general: Fixed a long outstanding bug which made axis tick marks
1726 disappear if MDataFormula was used (eg. abs(x))
1727
1728 - general: Updated MMath with new functions to calculate the results of
1729 a exponential, logarithmic and powerlaw fits analytically.
1730
1731 - general: Updated some macros with comments:
1732 + macros/optim/optimdisp.C
1733 + macros/optim/optimenergy.C
1734 + macros/optim/optimwobble.C:
1735
1736 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1737 files) now allows adding a pre-cut like in the optimization. E.g. this
1738 is useful to perform g/h-separation cuts before training the random
1739 forest.
1740
1741 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1742 correctly assigned in the raw data assignement table. A fix to correct
1743 the assignment tabel have been implemented.
1744
1745 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1746 by 90, 180 and 270 deg.
1747
1748 - general: the macro plotdb.C now allows to highlight sequences belonging
1749 to a datset. For more details see the descritions in the macro.
1750
1751 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1752 of the display, it gave wrong results espacially for big sizes.
1753 Now the embedded canvas should always have a ratio width/height=3/2.
1754 The "Size" options have been updated with values fitting the 3/2
1755 size ratio.
1756
1757 - RanForest:
1758 + Updated the random forest classes to support also the
1759 regression method implemented by Thomas H.
1760 + added new tutorial macro how to train the random forest
1761 for energy estimation (macros/optim/rfenergyest.C)
1762 + new classes to train the random forest (still in development)
1763 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1764 + new tutorial macros for random forest training in macros/train
1765 trainenergy.C, traindisp.C, trainseparation.C
1766
1767 - mars: now allows to setup a cut in the resource file mars.rc to choose
1768 the events to be displayed, eg:
1769 Cut.Condition: {0} && {1}
1770 Cut.0: MHillas.fSize>100
1771 Cut.1: MHillas.fSize<900
1772
1773 - merpp: Made aware of the new .rep format 200510250. This includes
1774 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1775 the discriminator thresholds (MCameraTD) and the disciminator
1776 delays (MCameraTD). All of them come with the CC report and are therefor
1777 written to the CC tree.
1778
1779 - callisto: fixed a bug in the calculation of the arrival times in
1780 the Digital Filter. They were all shifted by the same amount
1781 fHiGainFirst. This caused an offset in the order of the position of
1782 the left border of the extraction window in the times calculated
1783 from high-gain and from low-gain. The bug effected only the absolute
1784 arrival times. The bug was there since 30.1.2005.
1785
1786 - callisto: Changed the ExtractionWindow for the pulse position check
1787 such that the camera inhomogeneity becomes as less as possible and
1788 comparable to the pulso position check switched off. More details
1789 on the study will be given at our result web-page.
1790
1791 - ganymed: ganymed.rc, ganymed_onoff.rc:
1792 changed to new cuts trained with 1ES1218 and Crab-data
1793 for maximum sigma*log10(excess)
1794
1795 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1796 a new option was implemented to estimate Disp (CalcDisp)
1797
1798 - ganymed: Implemented two new options which allow
1799 to overwrite the default path to search for the sequence files
1800 --ins=/magic/sequences
1801 and where to search for the image data
1802 --ind=/magic/data/star
1803
1804 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1805 dx/dy from the resource file by
1806 MSrcPosCorrect.Dx
1807 MSrcPosCorrect.Dy
1808
1809 - ganymed: fixed reading the source catalog. Only as many chars
1810 as the requested source name had were compared (If a source
1811 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1812 were requested it could happen that the coordinates of
1813 "1ES1218" were read) The source coordinates are now printed
1814 in addition to its name to the logging output.
1815
1816 - ganymed: changed the background fit in the case of a ThetaSq function
1817 from a polynomial to a exponential, this should give a big improvement
1818 for on-only analysis'
1819
1820 - ganymed/sponde: Calculation of the error of single size-/energy-
1821 bins now uses Li/Ma (5) instead of LiMa (17)
1822
1823 - sponde: Added a plot E^2*dN/dE
1824
1825 - sponde: The energy estimator plot should now show values like
1826 they are commonly used.
1827
1828 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1829 (a powerlaw with cutoff didn't work before)
1830
1831
1832
1833 *** Version 0.9.4.2 (2005/10/01)
1834
1835 - general: added new tutorial macro macros/tutorials/threshold.C:
1836 how to calculate the threshold
1837
1838 - general: added a new game. Start it from the interpreter with
1839 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1840 and MagicReversi)
1841
1842 - general: neighbor pixels in MGeoms are now sorted clockwise
1843
1844 - merpp: made aware of new format 20050829-0
1845
1846 - callisto: New scale factors from muon analysis, stored in new
1847 resource file resources/calibration.rc
1848
1849 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1850 the eventloop if something went wrong. This is necessary for the
1851 automatic processing
1852
1853 - callisto: Implemented a new treatment for the time information
1854 developed by S.Ruegamer, this should give much better response than
1855 the old very primitive algorithm. This is especially important
1856 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1857 treatment was buggy! As neighbor pixels to interpolate the
1858 arrival times always the pixels 0 to 5 were taken)
1859
1860 - callisto: In addition to the new treatment of arrival times the
1861 decision of the treatment whether a pixel contains shower
1862 information or not is used to improve the signal interpolation
1863 further. Previously interpolated pixels showed a non-zero signal
1864 do the peak searching signal extractors. Having a signal pixel
1865 beside raised the signal above the cleaning level. Thus the
1866 pixel survived cleaning to often but with a too low mean signal.
1867 By replacing empty pixels with a gaus (mean and rms from the
1868 corresponding Area entries in MPedPhotCam) this effect can
1869 be supressed.
1870
1871 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1872 got lost when the events were stored by the calibration... fixed.
1873 (This was no problem for normal image cleaning because the pixel
1874 content was artificially set to 0 not surviving standard cleaning
1875 algorithm)
1876
1877 - callisto: Fixed a bug which caused the random and peak-search pedestal
1878 extracted with an extractor to be exchanged for the first (roughly)
1879 500 events (*Extractor and *ExtractorRndm).
1880 (They were simply exchanged in callisto.cc) This bug might have been
1881 introduced in Mars 0.9.4 when the order of calculation of the two
1882 types of pedestal in callisto got exchanged. The bug only effects
1883 the first seconds of data of each sequence.
1884
1885 - star: Taking the arrival time of Muons into account the calculation
1886 of the parameters could be made independant of the noise
1887 (pedestal rms). The dependance was due to the bias of the peak search
1888 extractor. Now only a ZA dependamcy is left which is not yet fully
1889 understood.
1890
1891 - ganymed: The sequences were still not sorted correctly in any case,
1892 because they were sorted by the full qualified path name. Now they
1893 are sorted by their sequence number.
1894
1895 - ganymed: new values for the spark-event-cut
1896
1897 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1898
1899
1900
1901 *** Version 0.9.4.1 (2005/08/18)
1902
1903 - callisto: fixed some problems with the calibration in case of
1904 inteleaved events. Therefor the final and some intermediate
1905 fits are skipped which would take place on partly filled #
1906 histograms and gave wrong results or failed completely.
1907
1908 - callisto: If the intermediate finalization of the histograms
1909 calculating the mean charge of the calibration signal fails
1910 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1911
1912 - ganymed: Fixed some bugs which caused problems in On-only mode.
1913 Still the false source plot doesn't give reasonable results.
1914
1915
1916
1917 *** Version 0.9.4 (2005/08/05)
1918
1919 - general: Fixed the ZA binning. It did not correctly fit the
1920 MC binning
1921
1922 - general: Added a class to correct for the missfocussing in
1923 April (MSrcPosCorrect)
1924
1925 - general: Random Forest energy estimator should now work properly
1926
1927 - general: MHCamera now displays the profiles in deg instead of mm
1928
1929 - general: MH::SetPalette offers a lot of new palettes
1930
1931 - general: MHillas - the case of CorrXY==0 is now handled properly
1932
1933 - general: implemented the possibility to change the line and
1934 marker style of a sky-grid drawn by MAstroCatalog
1935
1936 - general: Runs in sequences and datasets are now automatically
1937 ordered (it is assumed that the order of their filenames correctly
1938 represents the order of observations) to ensure correct reading
1939 of the subsystem data
1940
1941 - general: Runs cannot be added to a sequence twice anymore. Also
1942 Sequences cannot be added twice anymore to a dataset.
1943
1944 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1945 It gave wrong results by 1./2pi
1946
1947 - showplot: got a new option to start a root interpreter, too
1948
1949 - mars: now displays a rough estimate of Disp and the third moment
1950
1951 - mars: now displays the event time MTime if available
1952
1953 - mars: show muon parameters graphically
1954
1955 - mars: now the file to open can be given as commandline
1956 argument
1957
1958 - merpp: Added support for new arehucas version >= 200507190
1959 implementing values for three temperature sensors in the
1960 counting house (MCameraAUX) and the name of the HV settings file
1961 (MCameraHV).
1962
1963 - merrp: Also fixed some problems with wrong versions numbers stated
1964 by arehucas and implemented some fixed for old versions (<200407070)
1965
1966 - callisto: MCalibrationHiLoCam can now be printed from its context
1967 menu, eg in the TBrowser
1968
1969 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1970 - 1.39 (MExtractTimeAndChargeSpline)
1971 - 1.40 (MExtractTimeAndChargeDigitalFilter)
1972 This is important mainly for timing studies.
1973
1974 - callisto: Changed limits in MHCalibrationChargeCalc from
1975 - -100.125 to -98 (fgChargeHiGainFirst)
1976 - 1899.875 to 1902. (fgChargeHiGainLast)
1977 - -100.25 to -99 (fgChargeLoGainFirst)
1978 - 899.75 to 901. (fgChargeLoGainLast)
1979 Introduced new limits:
1980 - fgNumLoGainBlackoutLimit: 0.05
1981 - fgLoGainBlackoutLimit: 3.5
1982 - fgLoGainPickupLimit: 3.5
1983
1984 - callisto: The handling of automatic weights for the digital filter
1985 has been improved. There are now new calibration weights special
1986 for Monte Carlo calibrations.
1987
1988 - callisto: Updated Muon scale with latest results (1% difference
1989 for most data, 5% for Mar/Apr'05)
1990
1991 - callisto: use a new criterium to exclude bad pixels: If the high-gain
1992 was saturated and the blackout-events in the low-gain exceed the
1993 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
1994 This excludes those pixels which have a saturating high-gain
1995 channel, but the low-gain switch does not switch often enough
1996 to make the distribution reliable.
1997
1998 - callisto: fix a bug counting the number of saturated events. Up to now,
1999 the number of saturated slices was counted (which is one for a not too
2000 high number), but for some (pathological) pixels, many more slices
2001 saturated and produced wrong limits.
2002
2003 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2004 + MCalibrationRelTimeCam.CheckFitResults: Yes
2005 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2006 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2007 + MCalibrationRelTimeCam.CheckOscillations: Yes
2008
2009 - callisto: introduce max. number of events for intercalibration,
2010 the rest gets skipped. Default: 4096
2011 The calibration causes too many un-reliable pixels if more
2012 than about 5000 events are treated (@500 Hz) because of the
2013 mode hopping of the VCSels. However, in the past, some
2014 calibration runs have been taken (erroneously) with more
2015 than 5000 events, especially the intensity scans where
2016 a good precision is needed.
2017
2018 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2019 photo-electrons for the spline extractor by 1-2% (correctly).
2020
2021 - callisto: The intercalibration is now done using a full f-factor
2022 method instead of a simple update. This makes things slower but
2023 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2024 changes.
2025
2026 - callisto: MPedestalY3 now uses the same extraction range as the data
2027 as calculated by MPedestalY2
2028
2029 - callisto: A check of the fraction of allowed unsuitable (10%) and
2030 unreliable (30%) pixels has been addded when the conversion is
2031 calculated from interleaved events
2032
2033 - star: fixed a bug which caused MEffectiveOnTime containers not to
2034 be written. In the worst case they were skipped almost all, in the
2035 best case they were all ok. It depends on how often the new value
2036 was assigned just with an event which was skipped later by another
2037 task
2038
2039 - star: new histograms MHPointing and MHRate
2040
2041 - star: New tab (Currents) displaying the time evolution of the mean
2042 DC currents
2043
2044 - star: New tab (MeanRms) displaying the time volution of the mean
2045 Pedestal Rms
2046
2047 - star: Output now contains MReportStarguider
2048
2049 - star: Improved muon analysis. Due to the absense of a constant
2050 for the gaus fit for arc width and the fact that the arcwidth
2051 plot was a histogram instead of a profile the resulting psf
2052 became pedestal rms dependant
2053
2054 - ganymed: added new plot (MHPhi) for wobble mode as described in
2055 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2056
2057 - ganymed: corrects now (correctly?) for the misspointing in
2058 May/April 05
2059
2060 - ganymed: Two new default templates for ganymed.rc are avilable:
2061 ganymed_onoff.rc and ganymed_wobble.rc
2062
2063 - ganymed: The first version of MFMagicCuts has been released
2064
2065 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2066
2067 - ganymed, sponde: There are two new options to determin the number
2068 of bins for the signal region (NumBinsSignal) and the number of
2069 total bins (NumBinsTotal) in the MHThetaSq histogram
2070
2071 - ganymed: optimized palettes for MHDisp
2072
2073 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2074 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2075 sqrt(2) to large
2076
2077 - ganymed: The false source plot (MHDisp) is now based on Disp
2078 and a background model determined in the first loop is
2079 subtracted
2080
2081 - ganymed: MFMagicCuts are now available in the cvs. The correct
2082 solution for the disp ambiguity problem is now calculated using
2083 the third moment. The third moment cut therefor is skipped.
2084
2085 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2086 already determined by the third moment along the major axis and
2087 so its actual sign is aligned along the major axis of the shower.
2088
2089 - ganymed: If starguider data is available it is taken into account
2090 when calculating the source position. This is especially important
2091 for wobble data at high zenith angles and culmination data.
2092
2093 - ganymed: If available the starguider data is taken into account as
2094 good as it is possible without a starguider calibration. To switch
2095 it off add
2096 MPointingDevCalc.MaxAbsDev: -1
2097 to your ganymed.rc
2098
2099 - sponde: the zenith angle distribution is now weighted instead of
2100 choosen by default. This gurantees higher statistics in the highest
2101 and lowest energy bins. To switch this behaviour off use...
2102
2103 - sponde: now automatically displays the energy threshold
2104
2105
2106
2107 *** Version 0.9.3 (2005/06/03)
2108
2109 - general: MMcEvt now derived from MMcEvtBasic which should
2110 have no influence on compatibility with older camera files
2111
2112 - general: Implemented a new option to MReadReports which allows
2113 to force reading of the first event of some trees (eg. Drive-tree)
2114 before any other tree.
2115
2116 - general: Made a fix to MPointingPosCalc which assumes that the
2117 run-type is real-data if Process is called before ReInit, such
2118 that also the very first Drive-events in a run are treated
2119 correctly.
2120
2121 - shoplot now displays the filename in the title bar of the window
2122
2123 - merpp: new options: --auto-time-start --auto-time-stop which
2124 allow to cut updating with slow-control at the start- or
2125 (previousle --auto-time only allowed: and) stop-time of
2126 the run stored in the runheader.
2127
2128 - callisto: changed default of fgFallTimeHiGain in
2129 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2130 already set as default in callisto_Dec04Jan05.rc
2131
2132 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2133 now changes the filename for new weights automatically for
2134 cosmics, MC and for different calibration colors.
2135
2136 - callisto: a problem with the order of some code cause the
2137 name of the weights file in MPedestalY2 to be ignored.
2138 Wrongly the calibration_UV weights were used instead
2139 of the cosmics weights set in callisto.rc.
2140
2141 - callisto: should allow ct1 pulser data when the color is
2142 explicitly set also for pretty new runs
2143
2144 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2145 to introduce an additional scale factor (should be around 1)
2146 to adapt for slight deviations in different extractors from
2147 the MC calibration. For MC calibrations the scale factor
2148 is fixed to 1
2149
2150 - callisto: MFCosmics should handle very high signals a bit
2151 more accurate now
2152
2153 - callisto: when calculating the mean pedestal rms for different
2154 pixel sizes or sectors also kUnsuitableEvt is now taken into
2155 account - not only kUnsuitableRun
2156
2157 - callisto: '-raw' option is now the default
2158
2159 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2160 This has the advantage that mean values in the calibration (eg
2161 arrival times) are calculated more accuratly.
2162
2163 - callisto: In the resource file callisto_Dec04Jan05.rc
2164 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2165
2166 - callisto: new Hi-/Lo-Gain intercalibration constants
2167 hilocalib_sp1.root and hilocalib_sp1_mc.root
2168
2169 - callisto: changed default for MJPedestalY2.MaxEvents
2170 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2171
2172 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2173 has changed from 9.0 to 6.0. This is necessary to exclude two very
2174 ringing pixels in September which - when kept - destroy the image
2175 cleaning around them (Markus G.)
2176
2177 - callisto: (!) The Muon analysis of all data taken so far has
2178 suggested that different extractors give slightly different
2179 absolute results after calibration, due to there different
2180 handling of the calibration- and cosmics pulse shape. Although
2181 the over all calibration seems to be a bit to pesimistic (or
2182 the MC seems to be a little bit - 3-5% - too much attenuated).
2183 There for correction factors have been introduced which correct
2184 the calibration constants by
2185 0.956937799 for Digital Filter (callisto.rc)
2186 and
2187 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2188 calibration. The main advantage is, that both data types can
2189 be easily analysed together and compared to the same MC sample.
2190 The factors are choosen such, that the reference is now a
2191 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2192
2193 - star: fixed a bug which caused the first bin of the histograms
2194 vs time to disapear in PostProcess. This gave wrong results
2195 on the screen. The output and all following programs not
2196 directly accessing the histograms haven't been affected
2197
2198 - star, ganymed: Made sure that always the first Drive-tree event
2199 is read and Processed before the first data event was read.
2200
2201 - ganymed: implemented the possibility to replace the standard
2202 false source plot with a different one. For example: If
2203 you want to use a Disp based FS plot use the resource:
2204 NameHistFS: MHDisp
2205 For details about the requirements of these plots look
2206 at the corresponding classes
2207
2208 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2209 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2210 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2211 case MAlphaFitter is setup correctly. For On-Only optimization
2212 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2213 RunOn() instead of Run(). For energy estimation MJOptimize
2214 has been replaced by MJOptimizeEnergy
2215
2216 - sponde: The input MC spectrum can now be weighted to fake a
2217 different spectrum. This is done via MMcSpectrumWeight. For
2218 more details see the class description and sponde.rc
2219
2220 - sponde: The paremeter comparsion plots are not scaled by
2221 their entries anymore. Instead the MC plot is scaled by using
2222 the result spectrum of the analysis. If the input MC spectrum
2223 and the result spectrum has different slopes the absolut
2224 normalization is normally wrong.
2225
2226
2227
2228 *** Version 0.9.2 (2005/05/20)
2229
2230 - general: Changed the default paths for calibrated data and image
2231 files. (The implemented access to these files doesn't yet exist)
2232
2233 - general: support for MRunIter has been removed from the job classes
2234 (use the setter functions of MSeqeunce instead)
2235
2236 - general: ProcessFile has been renamed to Process in all job classes,
2237 because ProcessFile is missleading
2238
2239 - general: The storage of the palette in MHCamera is now possible
2240
2241 - general: new bits describing unsuitable and unreliable pixels have
2242 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2243 kDeadPedestalRms, kFluctuatingArrivalTimes
2244
2245 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2246 versions newer than V200404070
2247
2248 - general: support for cc file versions newer than V200504130. Added
2249 support for active loads (MCameraActiveLoad) and central pixel
2250 (MCameraCentralPixel)
2251
2252 - general: added new histograms for image parameters versus size
2253 (MHVsSize)
2254
2255 - general: The eventloop now automatically calls PrintStatistics
2256
2257 - Status Display: Improved support for printing:
2258 + A default can now be set in .rootrc (for more details see
2259 MStatusDisplay::PrintPS)
2260 + A print dialog is opened so that printer and command line
2261 can be canged
2262
2263 - showlog: improved such that it handles different verbosity levels
2264 more accurate now. This mean you can suppress output when
2265 using showlog.
2266
2267 - showplot: improved
2268 + The new graphics formats have been implemented
2269 (pdf, svg, png, jpg and xpm)
2270 + Implemented an interface for printing. Because you can change
2271 the printing command from the command line you can use all
2272 the nice postscript tool. To print a booklet for example call:
2273 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2274 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2275 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2276
2277 - callisto: fixed a bug in the recognition of the calibration bit
2278 pattern. Concerns only intensity calibration. (The strength of the
2279 intensity has been updated in some cases)
2280
2281 - callisto: add a filter against PIN Diode events when running over
2282 calibration runs since some of the recent calibration runs have
2283 been taken with Pin Diode.
2284
2285 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2286 39943, 44833 in the calibration (MCalibColorSet)
2287
2288 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2289 been set to 1e-18 in callisto_Dec04_Jan05.rc
2290
2291 - callisto: in callisto_Dec04Jan05.rc: set value for
2292 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2293 statistics for the calculation of the mean pulse time
2294 of the cosmisc
2295
2296 - callisto: the charge limit in the calibration has been raised
2297 from 2.5 to 4.5
2298
2299 - callisto: new setup read from callisto.rc
2300 + MCalibCalcFromPast.fNumEventsDump
2301 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2302 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2303
2304 - callisto: MExtractTimeAndChargeSpline extractor:
2305 + The integration ranges were shifted by 0.2 FADC slices to the right.
2306 + unreliable handling of floating point values caused different
2307 results on different platform or with different compiler options:
2308 The new algorithm is numerically exact and more accurate because
2309 it doesn't calculate the integration position by multiple times
2310 adding the step-size (which results in numerical uncertanties
2311 exspecially if multiplied with large numbers)
2312 + A lot of fixes have been introduced which effects integrating the
2313 spline at the edges of the valid range. In this case any memory
2314 was randomly accessed. This behaviour can be tested replacing
2315 all MArrayF by TArrayF which perform a range check (but of course
2316 they are a lot slower)
2317 ! No result obtained with the Spline before can be trusted! Due to
2318 random memory access it might by completely random!
2319
2320 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2321 + extraction range in the high gain to 4.
2322 + weights file to cosmics_weights46.dat
2323
2324 - callisto:
2325 + introduce the check for fluctuating arrival times.
2326 + set charge limit to from 2.5 to 4.5
2327 + introduce asymmetric exclusion due to "deviating number of phes":
2328 Default: -9.0 +4.5
2329 + make deviating number of phes unsuitable (see David's findings).
2330
2331 - callisto: fixed the display of unsuitable pixels. The old change
2332 to a real profile in MHCamera broke it.
2333
2334 - callisto: The cosmics filter is used in MJCalibration now
2335 independant of the pulser color (formaly it was used only for
2336 CT1-pulser data). The threshold of number of max empty pixels
2337 has been raised from 2% to 5% in MJCalibration. The maximum
2338 fraction of rejected event is 50% otherwise the calibration has
2339 failed. The filter now ignores unsuitable pixels.
2340 Setup the filter from callisto.rc using "ContCosmics"
2341 (see MFCosmics::ReadEnv)
2342
2343 - callisto: changed default for fgOffsetFromLogain back
2344 from -2.8 to -1.8 in digital filter.
2345
2346 - callisto: for the common extractors
2347 + MExtractFixedWindow
2348 * MExtractTimeAndChargeSlidingWindow
2349 * MExtractTimeAndChargeSpline
2350 * MExtractTimeAndChargeDigitalFilter
2351 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2352 and fResolutionPerPheLoGain
2353
2354 - callisto: Updated the hi-/lo-gain intercalibration constants
2355 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2356 hilocalib_df6.root
2357
2358 - callisto: The default lo-gain extraction window for the
2359 MExtractTimeAndChargeSlidingWindow extractor has been increased
2360 from 6 to 8 to take the stretch of the pusle into account
2361
2362 - callisto (!!!): fixed an important bug in the setting of the
2363 incoming pedestal pointer to the signal extractor extracting
2364 pedestals. This bug caused the pedestals not to be subtracted
2365 correctly in the calibration afterwards. The effect was about 10%
2366 too high conversion factors for the digital filter and the spline
2367 and more than 40% for the sliding window.
2368 The bug existed since end of February! (Markus G.)
2369
2370 - star: added muon support to star. A new tab "MHMuonPar" is
2371 displayed. The lower right plot is an estimate of the point spread
2372 function. A reference value is displayed. To get the real PSF
2373 you must compare with MC. The setup for the muon analysis
2374 is done in star.rc. More informations can be found in
2375 MHSingleMuon and MHCalibParCalc
2376
2377 - star: The weather data is now displayed in star
2378
2379 - star: MEventRateCalc handles the calculation of the event rate more
2380 accurate now in case of the start of a new run inside a sequence
2381
2382 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2383 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2384 changed only minimally
2385
2386 - ganymed: (MJCut and MJOptimize) now displayes the number of
2387 excess events versus size. The energy estimation is done in
2388 MJSpectrum (sponde)
2389
2390 - ganymed: got support for using other variables than Alpha, eg. Theta.
2391 Therefor you need a class deriving from MHAlpha which supports
2392 this variable (one is already existing: MHTheta, which is now the
2393 default in ganymed). It is setup through ganymed.rc
2394
2395 - added a full featured spectrum program (sponde) which reads
2396 ganymed output and monte carlos and compiles a spectrum
2397
2398
2399
2400 *** Version 0.9.1 (2005/04/14)
2401
2402 - Fix bug on the arrival time reconstruction when using Digital
2403 Filter (in some marginal cases (10%) times were reconstructed shifted
2404 by 0.2 slices)
2405
2406 - all executables now return 2 where in previous versions -1 has
2407 been returned (gave problems with shell-scripts)
2408
2409 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2410 also done with a intercalibration input file
2411
2412 - a bug in the time fine adjustment of the digital filter has been fixed
2413
2414 - a lot of small fixes to calling TPad::Divide with a margin==0
2415
2416 - MStatusDisplay now shows the memory usage
2417
2418 - added a memory leak statistic after the eventloop
2419
2420 - MHadronness replaced by MParameterD
2421
2422 - MEnergyEst replaced by MParameterD
2423
2424 - wobble mode can now be switched on from the data-set
2425
2426 - switched on bad pixel detection for a pedestal level
2427 which is more than 5 times the variance
2428
2429 - Fixed default paths to be correct for the new data center
2430
2431 - Fixed handling of drive data. The pointing position in now
2432 copied to MPointingPos inside star for real and MC events
2433
2434 - made sure, that the sequences in a dataset are sorted by
2435 their number to ensure the correct synchronization
2436
2437 - added all resource files necessary to handle spline extraction
2438 of signal for the late 2004 and the early 2005 data
2439
2440 - update the reference lines for the december data
2441
2442 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2443 This is important for the Dec. and Jan. data where the calibration
2444 pulse position changes much.
2445
2446 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2447 filter. This corrects only an defective extraction of the MC at
2448 low-gain signals lower than 90 phes.
2449
2450 - fixed some slowdown in calibrating data with interleaved events from
2451 Jan and Dec. As a workaround made the pretty palette the default.
2452 The inverse Deep Blue Sea has a bug which slows down long calibration
2453 runs a lot.
2454
2455 - implemented new values from new starguider report as defined
2456 in TDAS00-07 V7.1 (eg SkyBrighness)
2457
2458 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2459 in starguider report (If you merpp the same reports with this version
2460 you'll get the correct units (arcmin) but a different result
2461 than with old versions (wrong units))
2462
2463 - Now the status display can also write PNG, JPEG and XPM (other file
2464 formats are still unsupported by root)
2465
2466 - added a lot of scripts and macros in directory datacenter used
2467 for automatic processing
2468
2469
2470
2471 *** Version 0.9 (2005/03/23)
2472
2473 - Calibration is now done autmatically into photo-electrons like
2474 decided by the Collaboration Board
2475
2476 - Reference lines in the display can be read from resource file
2477
2478 - Interlaced calibration events can be handled by callisto
2479
2480 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2481 and applied in callisto.
2482
2483 - class MJCalibTest can be called by callisto
2484
2485 - callisto can now run with three data types: rawdata, rootdata, MC
2486
2487 - added two classes mreport/MReportStarguider.cc and
2488 mreport/MReportStarguider.h for implementing starguider-data
2489
2490 - the output of merpp-update now contains starguider information:
2491 MReportStarguider and MTimeStarguider
2492
2493 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2494 values were lower than they should. This was more visible for high
2495 energy (Size) events.
2496
2497 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2498
2499 - added a new loop to callisto to support the correct extraction of
2500 the pedestal and pedestal rms through the signal extractor
2501
2502 - added class to perform fourier tranformation of a hexagonal structure
2503 (MHexagonalFT)
2504
2505 - added class to perform fourier tranformation of a hexagonal structure
2506 in a tasklist (MHexagonalFTCalc) example: hft.C
2507
2508 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2509 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2510 small pixels, example: extendcam.C
2511
2512 - added possibility to write data to memory (TTree) using MWriteRootFile
2513
2514 - added possibility to read a TTree stored only in memory by MReadTree
2515
2516 - new classes to deal with the interleaved calibration events:
2517 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2518
2519 - implemented filters to callisto to skip calibration events
2520
2521 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2522 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2523 the slices by statistics
2524 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2525 signal extractor without randomization
2526 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2527 with the signal extractor with randomization (extraction window is
2528 randomly fixed)
2529 The three kind of pedestal is not yet implemented (for speed reasons) as
2530 long as nobody really needs it:
2531 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2532 extracted with the signal extractor with randomization
2533
2534 - callisto now finds the pulse position in the data automatically
2535
2536 - implemented data reduction in calibrated data by reducing the precision
2537 of the stored floating point values (pedestal, rms and signal) to
2538 roughly 0.5%
2539
2540 - fixed showplot to make file format conversion (eg. converting a
2541 status display stored in a root file into a postscript file) in
2542 batch mode possible:
2543 showplot -b --save-as-ps[=outfile.ps] infile.root
2544
2545 - Allow class names as part of filter rules, eg
2546 (MFSupercuts) && (MHillas.fSize>100)
2547
2548 - fixed a lot of stuff to allow all programs to process MonteCarlo
2549 camera files.
2550
2551 - enhanced possibility to debug reading of resource file
2552
2553 - MDataChain should handle priorities of operator more
2554 accurate now
2555
2556 - completely revised the container in which the signal is stored
2557 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2558 * the new implementation is faster and
2559 * needs less storage space
2560
2561 - FIRST version which can process Monte Carlos through the
2562 whole chain of programs (callisto, star, etc)
2563
2564 - implemented new image parameters for the border length of
2565 the shower image (MNewImagePar2)
2566
2567 - implemented wobble-mode in ganymed
2568
2569 - new class (MJOptimize) taking care of all optimization processes
2570
2571
2572
2573 *** Version 0.8.6 (2004/10/05)
2574
2575 - New combined signal and time extractor
2576 MExtractTimeAndChargeDigitalFilter
2577
2578 - The Report for the trigger section in the CC run summary has been
2579 updated, and now the IPRs (Individual Pixel Rates) are available.
2580
2581 - new macros for database interaction: filldotrun.C, filldotrbk.C
2582
2583 - added new program which can convert colored output which was redirected
2584 into a file back into colored text (for example to display it with
2585 more): showlog
2586
2587 - added new program to display an MStatusArray of plots (stored with
2588 MStatusDisplay) from a file: showplot
2589
2590 - Added support for Sequences (MSequence). Sequences are blocks of run
2591 files containing the same calibration and belonging to the same
2592 source
2593
2594 - Added a new task (MTaskEnv) which can be used in setup files to switch
2595 between different tasks (for example to choose a signal extractor)
2596
2597 - Implemented automatic file splitting in MWriteRootFile
2598
2599 - After image cleaning an island index is assigned to all used pixels.
2600 The index corresponds to the order of the islands in size.
2601
2602 - added a cleaning which takes signal height _and_ arrival time into
2603 account: probability cleaning (for more details see MImgCleanStd)
2604
2605 - added a cleaning which takes takes the absolute number of photons
2606 times the area ratio as cleaning level
2607 (for more details see MImgCleanStd)
2608
2609 - Changed calculation of image parameters such, that it can be done
2610 for all used pixels or the pixels with a defined island index only
2611
2612 - implemented new image parameters displaying the number of islands,
2613 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2614
2615 - event display in executable changed to support also calibrated files
2616 (done with MJCalibrateSignal)
2617
2618 - added program doing the calibration and the signal extraction
2619 and signal calibration: callisto Most part of the setup is done
2620 by a resource file: callisto.rc
2621
2622 - implemented support for pixels with negative IDs (Raw file format
2623 version 4)
2624
2625 - implemented an new option in merpp (--auto-time) to get the time
2626 range for cc and/or caco data from the run header of the raw data
2627
2628 - New star-program (star and MJStar). Taking calibrated data from
2629 callisto/MJCalibrateSignal as input. The setup is done through
2630 a resource file: star.rc
2631
2632 - Added possibility to setup the eventloop in the mars-executable
2633 Camera Display by a resource file: mars.rc
2634
2635 - The the mars-executable Camera Display can now also read
2636 calibrated data files written by callisto/MJCalibrateSignal
2637
2638 - Added a new class which can calculate the source position in
2639 the camera from a pointing model known to be correct and
2640 the pointing model used for observations (MSrcPosFromModel)
2641
2642 - added a new version of the class calculating the effective on-time
2643 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2644 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2645 MHTimeDiffTheta.
2646
2647 - added the possibility to count how often a signal is above (or
2648 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2649 can replace MHTriggerLvl0)
2650
2651 - added ore convinient ways to set the axis-titles of your histograms
2652 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2653 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2654
2655
2656
2657 *** Version 0.8.5 (2004/08/06)
2658
2659 - new Signal Extractors: MExtractFixedWindowSpline
2660 and MExtractAmplitudeSpline
2661
2662 - implementes interleave in merpp to be able to merpp parts of a file
2663
2664 - implemented force-functionality to merpp
2665
2666 - star display to display star catalogs (MAstroCatalog)
2667
2668 - star display to 'mirror' stars to the camera (MAstroCamera)
2669
2670 - implemented a new cleaning option which allows cleaning scaled with
2671 the real ratio of the rms depending on the pixel size, not only the
2672 square root of the pixelsize (MImgCleanStd, MCameraData)
2673
2674 - removed obsolete MBlind* classes
2675
2676 - Signal extractor taking the AB flag into account implemented (this makes
2677 an odd number of slices for signal extraction possible
2678 (MExtractSignalABcorr)
2679
2680 - implemented a class extracting the pedestal from the raw-data (events)
2681 itself using empty lo-gain (MpedCalcFromLoGain)
2682
2683 - Added mean values to MPedPhotCam
2684
2685 - Added Makefile for Darwin (this OS is NOT officially supported!)
2686
2687
2688
2689 *** Version 0.8.4 (2004/04/19)
2690
2691 - new fast arrival time extractor using cubic splines:
2692 MExtractTimeFastSpline
2693
2694 - implementes multi-argument support in MDataChain
2695 ("pow(a, b)")
2696
2697 - implemented double reference support in MDataChain
2698 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2699
2700 - added support in MF for expressiond like
2701 "MHillas.fWidth<2*<MHillas.fLength"
2702
2703 - MDataChain is now able to support variables like [0], [1], ...
2704 which can be used in fit functions as parameters. The interface
2705 is implemented through the new virtual function
2706 MParContainer::SetVariables
2707
2708 - added new class MArrivalTimeCam/MArrivalTimePix:
2709 Storage containers to hold the ArrivalTime of the camera/pixel
2710
2711 - added new classes for the calibration of relative arrival times:
2712 MCalibrationRelTimePix and MCalibrationRelTimeCam
2713
2714 - added new classes to extract the signal of the blind pixel and the
2715 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2716
2717 - added new classes for the bad-pixels treatment (MBadPixels*)
2718 which are more powerfull than the old ones (MBlindPixel*)
2719 and will replace them.
2720
2721 - added filter against cosmics: MFCosmics
2722
2723 - added new class MArrivalTimeCalc2:
2724 Calculates the arrival time as the signal weighted mean of the time
2725 slices in the maximum window
2726
2727 - added a new macro call pointspreadfucntion.C that fits with a 2D
2728 gaussian the DC spot for an star. It gives you the RMS of
2729 the PSF and the center of the star, very useful for misspointing
2730 studies.
2731
2732 - added support for multi-telescope camera files. Added classes
2733 MStereoCalc and MStereoPar, classes to calculate and store shower
2734 parameters calculated from the data of two telescopes, for the MC
2735 studies regarding the MAGIC clone.
2736
2737 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2738 MC data calibrated in photons instead of ADC counts.
2739
2740 - added three macros to show the calibration and analysis chain of
2741 MC data. The macro starmc.C does both calibration and analysis, producing
2742 an output containing Hillas parameters for each event. The macro
2743 mccalibrate.C does just the calibration and writes out a file containing
2744 pixel information in photons instead of FADC data. The macro starmc2.C
2745 reads in such a file and produces an output with Hillas parameters.
2746
2747 - added MPedPhotCalc to compute pedestals in units of photons, see
2748 macro pedphotcalc.C
2749
2750 - added all class to perform the calibration, see macro calibration.C
2751
2752 - added class MFFT to perform Fast Fourier Transforms
2753
2754 - added class MSimulatedAnnealing to perform simulated annealing
2755 minimizations
2756
2757 - added new macro bootcampstandardanalysis.C which holds the skeleton
2758 of the analysis chain discussed in the december bootcamp.
2759
2760 - added support for DAQ raw data file format V2
2761
2762 - implemented an arbitrary time stamp for the events from raw-data
2763 files with file version<3. It is calculated from the run number,
2764 the date of start and the FADC clock tick from the first module
2765
2766 - implemented the correct decoding of the event time-stamp
2767 coming from the DAQ for raw-data files with file-version>2
2768
2769 - added a new classes storing the pedestals in units of photons:
2770 MPedPhotPix, MPedPhotCam
2771
2772 - added support for DC current files from the camera control
2773
2774 - added support for start- and stop-time when merpping report files
2775
2776 - added MReportCC storing the weather data from the CC-REPORT
2777
2778 - added class to fill trainings and test matrices (MTFillMatrix)
2779
2780 - added a filter performing a software trigger (MFSoftwareTrigger)
2781
2782 - Added classes to perform parts of the standard analysis (Jobs):
2783 + MJPedestals
2784 + MJCalibration
2785 + MJExtractSignal
2786 Note: All of them are preliminary!
2787
2788 - Added Iterator to iterate over files giving only the run-number
2789
2790 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2791 the evolution of a sector vs time
2792
2793
2794
2795 *** Version 0.8.3 (2003/12/05)
2796
2797 - adapted Random Forest classes to allow the use with MC
2798 multi-telescope files which can be produced with the coming
2799 camera version 0.7.
2800
2801 - added classes to read and interprete central control report files
2802 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2803
2804 - enhanced merpp (the executable) to support .raw and .rep files.
2805
2806 - added classes for light calibration (MCalibration* and
2807 MHCalibration*) by Markus Gaug. Further work has to be and will
2808 be done soon.
2809
2810 - Added a preliminary 'synchronizer' (MReadReports) which will
2811 replace MReadMarsFile as soon as it is finished.
2812
2813 - Added a tutorial macro demonstrating how report files are merpped
2814 and how they can be read from the root file in the correct order
2815 of time (readrep.C)
2816
2817 - Added a generalized histogram (similar to MH3) called MVsTime
2818 which allows to plot variables (or rules - MDataChain - of
2819 variables) vs time. For an example have a look at tempvstime.C.
2820
2821 - Changed the name of the event trees:
2822 + Events --> Events
2823 + PedEvents --> Pedestals
2824 + CalEvents --> Calibration
2825
2826 - changed name of MTime in the event trees from MRawEvtTime to MTime
2827
2828 - added displaying the sector indices to the mars event display
2829
2830 - Magic Online Analysis (MOnA) implemented in a first version
2831 (see mona.cc, MOnlineDump and MOnlineDisplay)
2832
2833 - added classes to calculate event rate
2834 (preliminary: MEventRateCalc, MEventRate)
2835
2836 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2837
2838 - added classes dealing with the telescope pointing position (MPointing*)
2839
2840 - implemented the 'final' Mars time stamp based on some experiences with
2841 the new 'Synchonizer'
2842
2843
2844
2845 *** Version 0.8.2 (2003/11/10)
2846
2847 - accelerated standard analysis by a factor of 6-8 ...
2848 + doing precalculations in MGeomCam for the pixel area ratio
2849 + creating a look up table for the single pixels in MCerPhotEvt
2850
2851 - added task to calculates weights in case you want to 'change'
2852 the energy spectrum of a monte carlo file
2853 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2854
2855 - added a new executable star which implements the
2856 star.C macro as precompiled executable. Currently a flexible
2857 setup is not possible, but a 'input card' setup will follow.
2858
2859 - Starting to implement Multi-Telescope-Support based on the
2860 upcomming camera version 0.7. The base for a general support
2861 is implemented and the star-functionality is proven to work.
2862
2863 - Replaced Event-Display in and Camera-Display in the Mars GUI
2864 executable by a more convinient display base on MStatusDisplay.
2865
2866 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2867
2868
2869
2870 *** Version 0.8.1 (2003/10/20)
2871
2872 - added signal subtraction for pure on data by means of fitting
2873 the background in the off region or by performing a combined
2874 signal/background fit. Provides necessary histograms for
2875 obtaining energy spectra and a light curve.
2876
2877 - added classes to perform and study the selection of the
2878 2nd Level Trigger on MC data (example in triglvl2.C macro)
2879
2880 - added pedestal calculation
2881
2882 - implemented "democratic cleaning" (tail cut value proportional
2883 to pixel area) according to Wolfgang's suggestion.
2884
2885 - added Sigmabar treatment (calculation and basic histogramming)
2886
2887 - added basic routines to apply padding
2888
2889 - added first implementation of MARS-based source visibility plotter
2890 (needs to be linked against slalib, preliminary version)
2891
2892 - enhanced functionality of data chains: random numbers, conversion
2893 functions and access to MHMatrix objects
2894
2895 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2896 numbers under certain circumstances (runs with 0 events included)
2897
2898 - fixed a bug in the general filter MF (didn't work on some systems
2899 at all)
2900
2901 - fixed a bug in chaining files, which caused the analysis to crash or
2902 ignore files
2903
2904 - implemented more geometry classes describing the parameters used
2905 to simulate the PMT camera
2906
2907 - added new Monte Carlo classes containing the setup of the different
2908 programs in the MC chain.
2909
2910 - added a (preliminary) general task to evaluate chi-square of a given
2911 parameter in an eventloop.
2912
2913 - first implementation of a container describing the observatory
2914 location (Long, Lat, etc)
2915
2916 - added Random Forest - method for g/h-separation
2917
2918 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2919 (this means, that it is compiling, but not yet fully tested)
2920
2921 - added a new status display which can show the present status
2922 of histograms while an eventloop is running (MStatusDisplay,
2923 an example can be found at status.C)
2924
2925 - reorganized directories:
2926 classes describing the image --> mimage
2927 classes containing Monte Carlo Histograms --> mhistmc
2928 classes for Random Forest method --> mranforest
2929
2930 - added (event-)weights to fill histograms
2931
2932 - colors in logging output to screen
2933
2934 - changes to the Image Parameter declaration:
2935 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2936 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2937 + MHillasExt now derives from MParContainer instead of MHillas
2938 --> Files written with the old definition are more or less unreadable
2939
2940 - reading of reflector files
2941
2942 - display data from reflector files in the camera
2943
2944 - implemented currents (and display them in the camera)
2945
2946 - logarithmic scale in camera
2947
2948 - added class to iterate through directory contents (MDirIter)
2949
2950
2951
2952 *** Version 0.8 (2002/11/18)
2953
2954 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2955
2956 - corrected 48(!) wrong entries in the Next Neighbor table of the
2957 Magic Camera (all in the inner part of the outer ring, mostly
2958 missing a single NN)
2959
2960 - Fixed a bug in the table describing the Next Neighbours of the
2961 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2962 have any neighbour)
2963
2964 - changed trigrate.C: now it calculates the pure NSB triggers from
2965 a camera file (generated with no showers), so there is no need
2966 to introduce them by hand in the BgR array (for more details
2967 please ask Abelardo)
2968
2969 - added MHHadronness (and MHadronness) as a general facility to evaluate
2970 the quality of a gamma-hadron seperation method
2971
2972 - changed MWriteAsciiFile to accept rules (MDataChain)
2973
2974 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
2975 must be replaced by calles to MWriteAsciiFile::AddColumn and
2976 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
2977 changed.
2978
2979 - Implemented generalized event-matrices (one row per event)
2980 (MHMatrix)
2981
2982 - implemented the one dimensional composite probabilities
2983 (MHCompProb, MCompProbCalc, comprob.C)
2984
2985 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
2986 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
2987
2988 - Added a camera display displaying the pixel numbers to the
2989 event display gui.
2990
2991 - Added Monte Carlo Informations to event display gui
2992
2993 - Changed the camera display to display the pixel numbering
2994
2995 - Added three buttons to the camera display to change the palette
2996
2997 - Added the number of used and core pixels after image cleaning
2998 to MHillas
2999
3000 - Changed the algorithm used in MHillas according to TDAS 02-03
3001
3002 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3003
3004 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3005
3006 - Added fCosDeltaAlpha to MHillasSrc
3007
3008 - The numbers of photons used to calculate fConc and fConc1 in
3009 MHillasExt are now scaled with the pixel size, so that one get
3010 a four times smaller value for the bigger pixels in the outer ring.
3011
3012 - added new task to smooth the camera contents (MCameraSmooth)
3013
3014 - added possibility to use interpolated pixel values for blind pixels
3015 instead of removing it completely from the analysis
3016
3017 - Implemented the possibility to save the whole eventloop with
3018 its setup to a file. This information can be read and from
3019 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3020 and MEvtLoop::MakeMacro. If you find something not working, please
3021 report - this stuff is still in a beta phase.
3022
3023 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3024 file having crab starfield, but also for all following files - fixed
3025
3026 - MTaskList::PrintStatistics can now be instructud to print also the
3027 title, too: use PrintStatistics(0, kTRUE)
3028
3029 - Changed the image cleaning so that pixels with to many 'used'
3030 neighbors are left used (to get rid of 'holes' in events)
3031
3032 - Introduced more output to the camera displays
3033
3034 - Added an array of histograms (eg one hist per run), MHArray
3035
3036 - Added a _preliminary_ version of the reader for CT1 PreProc files
3037 (MCT1ReadPreProc)
3038
3039 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3040 (thanks to Raquel)
3041
3042 - added the first energy estimator (MEnergyEstParam, estimate.C,
3043 estfit.C) using a parametrization
3044
3045 - Added some new Monte Carlo paremeter containers used to store
3046 setup information from the MC chain (MMcConfigRunHeader,
3047 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3048
3049
3050
3051 *** Version 0.7 (2002/04/30)
3052
3053 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3054 the pedestal mean value was saved incorrectly. For files from
3055 this versions we substract 0.5 from the pedestal mean.
3056 WARNING: This may effect your results, so don't wonder...
3057
3058 - First implementation of an algorithm using only triggered events
3059 for the collection area calculation
3060
3061 - Ascii Output can now also be used for parameter containers which
3062 doesn't overload MParCointainer::AsciiWrite
3063
3064 - The Ascii Output is now also capable of writing single data members
3065 of one container
3066
3067 - You are now able to change the order of the values written to the
3068 ascii file
3069
3070 - You can now specify a conversion factor for each data member written
3071 to an ascii file. This may be usefull to change the units of the
3072 data member (eg. degrees instead of millimeters in case of the
3073 hillas parameters)
3074
3075 - Replaced old MHillas by a new structure which allows you to extend
3076 the parameters stored in MHillas very easily:
3077 see MHillas and MHillasExt
3078
3079 - Added classes to handle source dependancy of image parameters:
3080 see MHillasSrc
3081
3082 - Added container (MBinning) to have a standard input for the binning
3083 in different histograms (eg. the Energy bins should be the same in
3084 all histograms)
3085
3086 - Changed Hillas histograms from mm to deg
3087
3088 - Added the flexible binning to the hillas histograms
3089
3090 - Added a filter for the alpha parameter (MFAlpha)
3091
3092 - It is now possible to write single data members of a class object to
3093 an output stream instead of the whole container only
3094
3095 - Added a generalized filter for a data member:
3096 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3097
3098 - Added a generalized Filter parser for more difficult filter rules
3099 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3100
3101 - Added new Monte Carlo histograms:
3102 MHMcEnergyImpact and MHMcEfficiency
3103
3104 - Added many new histograms needed for the flux calculation.
3105
3106 - Added a generalized histograms which can fill and show up to three
3107 data members in either a one-, two- or three-dimensional histogram, eg:
3108 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3109
3110 - Added:
3111 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3112 * calculation of <Theta> as a function of time (MHThetabarTime)
3113 they are needed in the flux calculation in
3114 order to select for a given bin in Theta (or time) the appropriate
3115 effective collection area, which is assumed to be given as a function
3116 of Theta and the true energy
3117
3118 - Added calculation of the migration matrix in the energy
3119 (MHMcEnergyMigration):
3120 the migration matrix describes the migration from the true (E_true)
3121 to the estimated energy (E_est); it is needed to determine the
3122 distribution of E_true from the measured distribution of E_est
3123 by unfolding
3124
3125 - changed the color palette in the camera display to DeapSea.
3126
3127
3128
3129 *** Version 0.6 (2002/01/15)
3130
3131 - Introduce the option of disable pixels (MBlindPixels and
3132 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3133 able to deal with Star Field NSB.
3134
3135 - Fixed a bug in the pedestals substraction
3136
3137 - Introduced verbosity levels
3138
3139 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3140
3141 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3142 work correctly (thanks to Abelardo)
3143
3144 - Introduced correct treatment of the diffuse Night Sky Background
3145 and NSB (MMcPedestalNSB)
3146
3147 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3148
3149 - Introduced MMcRunHeaders which contains monte carlo run informations
3150
3151 - Added a 'Print'-Task (MPrint) which calls the Print function
3152 of a parameter container for each event
3153
3154 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3155
3156 - changes to be more efficient with root 3.02/06
3157
3158 - root 3.02/06 fixes:
3159 + the memory leak when reading MRawEvtData
3160 + loosing more time than necessary to update the progress bar
3161
3162 - MWriteAsciiFile is now capable of writing more than one container
3163 in a line. For example: To be able to write Monte Carlo and
3164 Hillas values (energy and alpha) in one line.
3165
3166
3167
3168 *** Version 0.5 (2001/11/06)
3169
3170 - Added new GUI functionality (Analysis)
3171
3172 - Added a camera display to be able to display events in the camera
3173 together with the calculated hillas ellipse
3174
3175 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3176 object at any state of the analysis, so that the output are several
3177 states
3178
3179 - Fixed a bug in the collection area error calculation
3180 (Thanks to Ciro and Abelardo)
3181
3182 - Fixed a bug which causes merpp to crash in some environments
3183
3184 - Implemented auto enabling scheme for Branches to speed up reading
3185 a lot (see MReadTree and MTask)
3186
3187 - Fixed a bug in the Histogram classes which caused histograms to
3188 be written to a file by MWriteRootFile without request
3189
3190 - changed the object I/O from the old stylish root I/O to the new
3191 'auto evolution scheme' This was done only for classes which are not
3192 yet used in Monte Carlo files, so that these files are still readable.
3193
3194 - Added support for a progress bar in MEvtLoop and MReadTree
3195 (see the Analysis Window in Mars for an example)
3196
3197 - Fixed a bug in the package creation which disturbed the conversion
3198 between a mars version unpacked from a tar file and the repository.
3199
3200 - Changed the code to writer merpped (converted into root format)
3201 raw files, to get faster (around 10%)
3202
3203
3204
3205 *** Version 0.4 (2001/09/20)
3206
3207 - This release is made to compile on a root version >= 3.00
3208
3209 - Fixed a bug which causes MReadTree to read the first file only
3210
3211 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3212
3213 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3214
3215 - Added a task to write several container to a root file (MWriteRootFile)
3216
3217 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3218
3219 - Added calculation of the collection area (MMcCollectionAreaCalc)
3220
3221 - fixed some bugs in the Hillas calculation
3222
3223 - added filters to be able to control the task execution dependent on
3224 a parameter (for example: the number of level 1 triggers in a MC-file)
3225
3226
3227
3228 *** Version 0.3 (2001/04/23)
3229
3230 - Many demo macros added
3231
3232 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3233
3234 - Hillas Calculation added
3235
3236 - Standard image cleaning available
3237
3238 - MReadTree is now able to handle more than one file
3239 (Remark: of the same structure)
3240
3241 - Now we are able to display events in a first version of the
3242 Camera event display. To do this we must run the macro
3243 "macros/readCT1.C" to read data from CT1.
3244
3245
3246
3247 *** Version 0.2 (2001/01/24)
3248
3249 - First Implementation of a Gui to read the raw data. Start the
3250 gui with the command mars.
3251
3252
3253
3254 *** Version 0.1 (2000/12/20)
3255
3256 - First official release 0.1
3257
3258 - Changes:
3259
3260 + changed calling style of MRawPixelIterator from do...while to
3261 while-loop
Note: See TracBrowser for help on using the repository browser.