source: trunk/MagicSoft/Mars/NEWS@ 9426

Last change on this file since 9426 was 9422, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 133.0 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 ;showplot:
11
12 * If a file without a MStatusArray is opened all object (not just
13 canvases) found in the file are drawn. Note that this may result
14 in empty tabs.
15
16 ;ceres:
17
18 * The night sky noise is now scaled with the sensitive area and
19 is given in units per square centimeter
20
21 * Added the possibility to add a cut after the image parameter
22 calculation (''Cut'')
23
24 * updated the PDE of the GAPDs with a more reliable curve from
25 the meeting page (linear extrapolate below 350nm)
26
27 * The impact distribution in the event distrbutions is now
28 perpendicular to Alt/Az and the histogram is displayed in 1D
29
30 * The GAPD PDE has been updated
31
32 * PDEs and mirror reflectivities have been linearily extrapolated
33 to match the wavelegth range between 290nm and 900nm
34
35 ;callisto:
36
37 * Fixed a bug which prevented MAGIC Monte Carlo file from being
38 calibrated (ceres files worked)
39
40 ;ganymed:
41
42 * added new starguider calibration for sequences since 1000534
43
44
45
46== Version 2.3 (2009/03/07) ==
47
48 ;SUGGESTION
49
50 * There is no need to re-run any data because no change took place which
51 could have an effect on the output. However, if you want a
52 meaningful SrcPos plot for your MCs in sponde you must re-process
53 star for your MCs first.
54
55 ;REMARK
56
57 * File produced with this release containing a camera geometry (which
58 are basically all files were produced as default) will not be readable
59 by older releases.
60
61 ;general
62
63 * fixed a few small bugs which could cause the display to crash in ganymed
64 and sponde
65
66 * in sequence file the date can now be omittet. In this case the
67 leading date with the underscore is missing in the expected filename
68
69 * the geometry class now also supports other geometries than just hexagons
70
71 ;automation
72
73 * added magnetic field Azimuth direction (ARRANG), currently
74 at ~ -7deg at La Palma
75
76 ;database
77
78 * plotdb.php: added default (sequences) for startup, added possibility
79 to set size of plot
80
81 * added a new table ''RunDataCheck'' which containes the rates after
82 image cleaning for every run which succeeded star. It can be
83 plotted using ''plotrundb.C''
84
85 ;merpp
86
87 * added support for Arehucas Version >= 200812140
88
89 * added support for Arehucas Version >= 200809030
90
91 ;mars
92
93 * The display now also displays the trigger pattern
94
95 * The display can now display ceres reflector (_R_) files
96
97 ;ceres
98
99 * added a uniformly distributed one-bin time jitter for the start of the
100 digitization. Otherwise the first photon would be digitized always with
101 the same alignment to the bins
102
103 * Added a plot showing the production height of the photons
104
105 * Moved the particle id from the event header to the run header
106
107 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
108
109 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
110
111 * Added many new options to control the tasks. For deatils see ''ceres.rc''
112
113 * Removed obsolete plots in pedestal and calibration mode
114
115 * Removed the non-NightSky photons from the plots where they are just
116 disturbing
117
118 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
119
120 * The daq event number now represents the readout number
121
122 * The camera ''electronics'' can now be ''switched off''
123
124 * A new tab ''Info'' now display basic things like the reflector
125 layout
126
127 * Improved reading speed for corsika files
128
129 * Improved memory handling (if a large ampount of memory was needed
130 for a single event all further events were stored in the same
131 memory and it was never freed, so the program took this memory
132 until the end)
133
134 * Converted the code from MMCS' reflector program to MSimAtmosphere
135 (instead of the tables build in for MAGIC Winter and Summer
136 atmosphere we use the values written by Corsika fitted to the
137 tabulated atmosphere given as input)
138
139 * For caluclating the displayed image parameters in ceres a basic
140 image cleaning removing isolated pixels is now done.
141
142 * The magnetic field direction (ARRANG) is now taken into account
143
144 * Added plot for the energy threshold after trigger ''Threshold''
145
146 * Added plot for the effective collection area after trigger ''TrigArea''
147
148 ;star
149
150 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
151
152 * The definition of fConcCore has slightly changed. The numbers
153 might decrease a little bit (the effect should be rather small)
154
155 ;ganymed
156
157 * added pointing model 328198
158
159 ;sponde
160
161 * The SrcPos plot for your MCs was so far meaningless because it just
162 displayes the MSrcPosCam data from the input star-files. Unfortunately,
163 this containes was never written to the star-files yet.
164
165 * A new Tab 'OnTime' is available which is an effective on-time
166 fit as in star but for all data. This is mainly for manual cross-check
167 of the effective on-time
168
169 * In some circumstances it might be necessary to re-calculate the
170 eff. on-time from the fit in the new tab, e.g. when a zenith distance
171 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
172
173 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
174 it to its own output file (for convinience)
175
176
177
178== Version 2.2 (2009/01/30) ==
179
180 ;SUGGESTION
181
182 * This release doesn't contain a major change which is expected to
183 change your results. Nevertheless there are small changes to
184 the calibration which can effect at least the first few hundred
185 events in any (mainly MUX and even more SUM) sequence a little bit.
186 So it is recommended although not necessary to reset your sequences
187 in the database before further processing.
188
189 ;NEW
190
191 * A first implementation of a Monte Carlo simulation program
192 (ceres - Camera Electronics and REflector Simulation) has been
193 implemented. It can simulate a full telescope already including
194 a complete reflector simulation and a flexible trigger and readout
195 simulation. Currently, no perfect setup is implemented and
196 especially the output of the program (data structure) should
197 be considered alpha state. Also the user interface is not yet
198 ready.
199
200 ;general
201
202 * All command line options after -- are now interpreted as
203 arguments (usually everything which doesn't start with a minus)
204 rather than options (usually everything which starts with a
205 minus). This allows to use file names starting with a -
206
207 * In all resource files you can now initialize the random number
208 generator. For details see: MJob::InitRandomNumberGenerator
209
210 * added a new program called ''readcorsika''. It's purpose is (in analogy
211 to readraw and readdaq) to read a Corsika output file (for now
212 only cherenkov output is supported) and print its contents in a
213 human readable form. It can also write the contents of this file
214 into a root-file.
215
216 * The calculation of the maximum distance to the origin in a MGeomCam
217 has been improved (edges might be further away than the sides).
218 This is just a tiny change but it might change the appearance of
219 the radial profiles a little bit.
220
221 * The default binning of the center-of-gravity plot has slightly been
222 increased
223
224 ;Database
225
226 * Added informations about the DC currents (fMinCurrents, fMedCurrents
227 and fMaxCurrents). The values are retrieved from the plots showing
228 the average DC currents of all pixels versus time.
229
230 * Websites with tables have now the opportunity to remove lines
231 ('-' button at beginning of each line) and get all lines back
232 ('+' at top of the column)
233
234 * Websites: added option to query only sequences containing sumtrigger
235 events
236
237 * Websites: added option to group by date (year, month, night) for runs
238 and sequences and enabled that combining of different group-bys,
239 e.g. status, date and source is possible
240
241 ;automatic analyis
242
243 * Rewritten producing plots in the web.
244 New plots, namely the output of plotoptical.C (extinction curve from
245 KVA), plotstat.C (status of the automatic analysis (percentage of
246 processed, analysed data etc.)) and plotusage.C (statistics of the
247 condor usage in the data center) has been are available now next to the
248 plots of plotdb.C
249 Mean values from the plots (output of the macro) are provided in a
250 txt file now.
251 The creation of the plots for callisto, star and ganymed in the web is
252 now steered via database. Consequently the plots are faster and
253 reliable up-to-date.
254 For all plots, a new layout is available facilitating the browsing
255 through the plots and providing additional information on the
256 displayed values. (tabs.php) These plots are linked from the DB
257 websites and the wiki.
258
259 ;statusdisplay
260
261 * The ''Loop'' entry in the menu bar now contains an option to pause
262 the loop and to process single events.
263
264 ;merpp
265
266 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
267 instead of RunHeaders)
268
269 * Now allows to merpp files newer than 2008/09/03.
270
271 * Added fixes for wrong (wrong or double) run- and file-numbers
272 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
273
274 ;callisto
275
276 * Extracting the pulse position for the pulse position check events
277 with sum trigger were denied. This decreased the statistics
278 extremely and therefor the resulting puse position was calculated
279 quite weak. Now sum events pass the calculation if and only if they
280 have also a level 1 trigger.
281
282 * the extraction of pedestal events and pulse position from the
283 first data events is now more automatic and makes sure that
284 a more precise number of events is extracted independent of
285 the ratio with which pedestal events or events with signals
286 are contained in the data.
287
288 * Updated Muon calibration constants for all MUX data (teh changes were
289 all smaller than 5%)
290
291 ;star
292
293 * For the calculation of the effective on time all sum-triggered events
294 were skipped. Now all Level1-triggeres events will pass. This might
295 result in a slight inaccuracy of the effective on time.
296
297 ;ganymed
298
299 * If the source position is more than 1deg away from the camera
300 center an error is raised now.
301
302 * Hopefully fixed the bug ''ganymed crashes when resized''
303
304 ;sponde
305
306 * Fixed a problem which causes the fitted spectral slope to be displayed
307 incorrectly. If you use MJSpectrum::FormFlux in your macros make
308 sure that the parameter 0 of your fit is negative.
309
310 * Added a histogram showing the read source position of your MCs
311
312
313
314== Version 2.1.1 (2008/08/04) ==
315
316 ;Database
317
318 * Added the median number of photo electrons from the calibration
319 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
320 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
321
322 * Added fTotOnTime, which is the on-time as given by the run-headers
323 (in contradiction to fAbsOnTime which comes from CC)
324
325 * Added new primaries for the new data structure (Magic II): for the
326 tables dealing with sequences (SequenceBuild Status, Sequences,
327 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
328 this is the telescope number (fTelescopeNumber) for the tables dealing
329 with runs (RunData and RunProcessStatus) this is in addition the file
330 number (fFileNumber)
331
332 * Added column fPriority to the status tables to be able to steer the order
333 in which the data is processed. As default the run, sequence and dataset
334 number are used.
335
336 ;automatic analyis
337
338 * Adapted scripts to the new data structure: They can handle now different
339 telescopes (getting the information as usual from the database).
340 The paths for Magic 2 are not yet implemented.
341
342 ;general
343
344 * should work now with root 5.20/00 (please note that root 5.20/00
345 we encounter crahses in the status display which are ot yet
346 understood)
347
348 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
349 instead of the base name of the file. This makes them easier to
350 access from the code
351
352 * Default Monte Carlo names in MSequence do not require the _E at
353 the end anymore
354
355 * where abrrevating a sequence file with a sequence number is possible
356 also "telescope:sequence" is now accepted, e.g.:
357 star 2:2000123 --out=output
358 see the programs' help for more details.
359
360 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
361 from the database. See the constructors for more details.
362
363 * MReadTree now supports friends
364
365 * MReadTree can now read also files not written by MARS and store
366 the data encapsulated in emulated MParContainers
367
368 * added a new starguider calibration valid since 15.1.08
369
370 ;showplot
371
372 * showplot can now read more than one file at once. This is especially
373 inetersting if reading files containing pure canvases
374
375 ;merpp
376
377 * we merpp the dc currents now also from the camera reports (they have
378 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
379
380 * In the automatic analysis we omit merpping of the currents from the
381 caco files and use the lower rate camera reports from the cc files
382 instead
383
384 * merpp has been redisigned to allow merpping of the cc-reports
385 of a whole sequence. This allows to design a very simple analysis:
386 mkdir output
387 ./callisto 100776 --out=output
388 ./merpp 100776 output
389 ./star 100776 --ind=output --out=output
390 Instead of the sequence number also sequence files are accepted.
391
392 * Implemented a fix for run-numbers between 1001348 and 1001396
393 which were incorrectly assigned by the cc.
394
395
396 ;callisto
397
398 * added a filter again which was was removed in the last release.
399 it removed the most brightest events. This should not change
400 any analysis result because these events are so bright that
401 they cannot be analysed anyway, but the bad-pixel plots doesn't
402 show outliers.
403
404 * updated muon calibration constants for the periods 51-57,
405 58-63 and 67-
406
407 ;star
408
409 * The camera currents are now displayed with the rate of the camera
410 reports instead of the caco reports
411
412 ;ganymed
413
414 * if mc camera files are new enough (>=8) the source position in the
415 camera is now calculated from the stored telscope and shower
416 orientation (Note, that this might not be suitable in all cases
417 depending on the aim of the study. These case still needs
418 implementation)
419
420
421
422== Version 2.1 (2008/06/18) ==
423
424 ;Database
425
426 * introduced average temperature and wind speed from star-files
427
428 * introduced average values from Pyrometer (mainly Cloudiness)
429
430 * introduced the ratio of accepted calibration events in the
431 calibration run
432
433 * introduced the average rates of the different trigger pattern,
434 e.g. the rate of pedestal and calibration events, from the signal-file
435
436 ;general
437
438 * fixed GroupBy options in plot*.C macros
439
440 * only display KVA points (not the Tuorla points) in plotoptical.C
441
442 * all programs now allow to add resources to the ones from the resource
443 file or overwrite them from the command line. This can be done like this
444 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
445 if something seems to be wrong you can debug what the program is doing
446 using the option --debug-env=3
447
448 * increased the diversity of debug levels. That also means that with -v3
449 you get now less output, i.e. only the output which is important for
450 an analysis. To get more output which helps for debugging try 4, 5 and 6.
451
452 * fixed a problem in the task synchronizing the reading of the reports
453 and the data stream. The effect was that in some circumstances the last
454 events of some trees could have been skipped. Since this is only a
455 very tiny part of the data no severe effect to your analysis results
456 is expected (an exception might be very short, i.e. singel runs,
457 datasets).
458
459 * Dataset file now allow to include the sequence file directly within
460 the dataset file and also allow to exclude single runs from the dataset.
461 (for more details see Class reference of MDataSet)
462
463 * Sequence files now allow for excluding runs from the analysis
464 (for more details see Class reference of MSequence)
465
466 * added code to process the sum-trigger flag
467
468 * the histogram classes MH3 and MHn now support profile histograms
469
470 * the histogram classes MH3 and MHn now support labels at the axis
471
472 * the Random Forest Train-classes (MJTRain*) now store the used datasets
473 in the output file
474
475 * the MFMagicCuts have a new option to allow a linear area cut (for
476 special studies)
477
478 * The liniking of the shared object is now done into a file defined
479 by 'mktemp'. This should be a local file system which accelerates
480 liniking a lot.
481
482 * The code has been prepared for compilation with root 5.18/00d
483
484 * The MHEnergyEst histogram now shows the distribution of
485 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
486 and (Eest-Emc)/Emc vs Emc.
487
488 * fixed mars (event display) for merpped raw-data and MC data
489
490 * adapted the synatx of sequence files to allow for the new run/file
491 scheme. For more details see class description of MSequence
492
493 ;showplot
494
495 * Added support for tiff files
496
497 * Added support for csv files (tables containing tab number,
498 name and title)
499
500 * Tabs now can have a title which is displayed in the postscript file
501
502 * When multiple file are written at once (e.g. pngs from a display)
503 it is now possible to use the tab name and or tab number in the
504 file name. For details see showplos's help.
505
506 ;merpp
507
508 * Implemented cc file version 2008-02-20/0
509
510 * Implemented cc file version 2008-05-19/0
511
512 * With new options merpping can be restricted (in addition to the
513 run-number) also by telescope and file number.
514 For details see "merpp --help"
515
516 * Implemented raw data format 11 (the most important change, except
517 from plenty of changes in the format definition, is the addition
518 of the file-number in the header) If nobody makes a mistake this
519 format should have the advantage that it is by definition forward
520 compatible, so old programs will be able to read newer formats.
521
522 * Added Pyrometer information to default output (stored in a new Tree
523 Pyrometer, needs a complete new merpp, i.e. new calibration)
524
525 * Merpping (also update) can now be restricted to one single report.
526 For example:
527 If you want to update an old file with Pyrometer information call
528 merpp --only=Pyrometer --update
529
530 ;callisto
531
532 * in the pedestal processing now at least 50 processed events are
533 required for succeeding.
534
535 * the signal and calib files now contain also the sequence information
536
537 * the two MPedestalCam in the calib file now have proper names
538 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
539
540 * Both pedestal cams now contain the number of events processed
541
542 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
543 i.e. for the extraction of the calibration pulses basically the average
544 over all events of the first slice instead of all slices was used.
545 Since pedestal and calibration constants are continously recalculated
546 this only effected the very first events of every sequence.
547
548 * For the extraction of the position of the maximum sample now the
549 extraction range is set automatically to the extraction window,
550 before the whole accessible range was used.
551
552 * If the number of samples in the events and the number of samples
553 in the run-header disagrees now an error is raised (this can
554 happen in not well simulated Monte Carlo files)
555
556 * In the case of MUX-data pedestal events with the lvl1 trigger flag
557 could survive into the pedestal calculation -- fixed.
558
559 * Tab "TrigPat" added showing the distribution of the trigger pattern
560 as found in the run-files (normalized with the run length)
561
562 * The selection of events from the trigger pattern has been improved.
563 If the trigger pattern is corrupted events won't pass anymore.
564
565 * Added a new command line option --dev-null to suppress output of
566 Y-files (this is useful for test cases)
567
568 * added a new tab "CalPos" showing the arrival time of extracted
569 interleaved calibration events
570
571 ;star
572
573 * the star file now contains also the sequence information
574
575 * Added a new command line option --dev-null to suppress output of
576 I-files (this is useful for test cases)
577
578 * Tab "Rate" added showing the distribution of the trigger pattern
579 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
580 the Y-files (normalized with the run length)
581
582 * The effective on-time calculation doesn't use events with only
583 sum-trigger anymore
584
585 * The data in the MHWeather tab has been reorganized. The never
586 working solar radiation has been removed and the data from
587 the pyrometer (cloudiness, air and sky temperature) is
588 displayed in addition.
589
590 ;ganymed/sponde
591
592 * Now data points are even shown correctly if they have error bars larger
593 than one sigma. Points with null or negative significances are omitted.
594
595 * DrawNicePlot now allows to set a projection range
596
597 * Updates pointing models. One is applied after the implementation
598 of the new LUTS in August, the other one is applied after the
599 next major change of the pointing model in October. Note that
600 these models are preliminary and give wrong results below Zd=65deg
601
602 ;sponde
603
604 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
605
606 * a new option "--force-runtime" is available. In case of very short
607 datasets (for light-curves) which are in the order of a few
608 minutes the calculated effective on-time is not very acurate because
609 it is quantizised in the order of a minute. Therefore you can switch
610 to using the real run-time instead (remakrt: this ignores any
611 dead-time!)
612
613 * a more analytical way is used to "fill" Monte Carlos into regions
614 of impact parameters which have not been simulated because the
615 trigger efficiency is assumed to be 0.
616
617 * estimated sensitivity curves for hi and lo zenith angles are shown
618 scaled to the correct observation time and collection area
619
620 * the Monte Carlo events after cuts are now written to the output file
621 if an output file given
622
623
624
625 *** Version 2.0 (2007/09/03)
626
627 - database: the position used for the pulse pos check was missing
628 in the callisto output and could thus not be filled into the DB.
629 Also the old values seemed not exactly the PulsePos used for
630 teh check.
631
632 - general: Resource file now allow an Include-Resource, i.e. you can
633 read a resource file with default settings, include it in your
634 resource file and overwrite the settings in your file. More than
635 one include file is allowed. Inclusions can be iterative.
636 Include: mydefaults.rc yourdefaults.rc
637 The resources in the first file have higher priority than the
638 second file.
639
640 - general: Now the output files (calib*.root, etc) also contain the
641 resource file (to check it open it in the TBrowser and choose Print()
642 from the context menu)
643
644 - general: Dataset files now allow to overwrite the default path
645 to search for sequence and data files. Note, that the program
646 option and individual resources will overwrite it. For example:
647 SequencePath: /magic/montecarlo/sequences
648 DataPath: /magic/montecarlo/star
649
650 - general: Fixed a problem with variables in MDataPhrase. It seems
651 that only optimdisp (didn't work) was effected.
652
653 - general: Some improvements to the optim and train processing. For
654 example the ststud window now got a proper title.
655
656 - general: The "Status Display: " was removed from the window title
657 within an Eventloop.
658
659 - general: added a new flexible histogram-class (MHn) which can be used
660 for example in testing after optimizations or training to produce
661 user defined histograms.
662
663 - general: The Random Forest now allows attaching an evaluation
664 function which is applied to its output. This allows to train
665 on whatever you like (eg. train on log10(energy), but return
666 energy)
667
668 - general: The Random Forest training of energy (trainenergy.c) and
669 disp (traindisp.C) has been improved by more graphical output to
670 judge the result.
671
672 - general: The training of energy (trainenergy.C) has been improved
673 a lot by training on a different quantity than energy. It gives
674 a result which is highly independant of the source spectrum
675 and shows lower bias than all other options.
676
677 - general: Dataset files are allowed to contain collections of
678 datasets. For more details see the class reference of MDataSet.
679
680 - general: The default WobbleMode in a datset file now (if not
681 overwritten) is "auto", i.e. wobble mode is set if the dataset
682 doesn't contain off-sequences.
683
684 - merpp: Merpp can read file format version 9 now. Please realize
685 that for file format version 9 the extraction range is different
686 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
687 the first and last 15 slices have been removed from all MUX data.
688
689 - mars: Similar to writing movies you can now select events which
690 should be displayed in your display. Therefore add the following
691 lines to your mars.rc:
692 MFEvtNumber.FileName: ganymed00223552.root
693 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
694 The input file can be a ganymed-file after (ganymed*.root) or
695 before (ganymed*-summary.root) file. For example to select all events
696 from your on sample after cuts (excluding the ThetaSq cut) use
697 MFEvtNumber.Selector: DataType.fVal>0.5
698 To show all events from your on-sample after quality cuts
699 use the summary file instead.
700
701 - mars: new ways to call mars are implemented. Instead
702 of calling
703 mars filename.root
704 you can now also use
705 mars sequence.txt
706 or
707 mars sequence.txt inputpath
708 or replace sequence.txt by the sequence number if the default
709 sequence file should be used.
710
711 - mars: The default size has been increased
712
713 - mars: There are two new heckboxes which allow to switch off
714 the calculated image parameters
715
716 - callisto: was broken for MCs... fixed.
717
718 - callisto: improved calculation of spline coefficients a lot. This
719 leads to a further improvement of the event rate calibrating MUX
720 data of about 15% (175evt/s instead of 150evt/s)
721
722 - callisto: finally the raw data we read is now real 16bit (with
723 10bit precision) for MUX data and not a stripped 8bit number
724 anymore. Due to scaling of the numbers (without precision loss
725 into an [0-256[ range, the final numbers for pedestal, pedestalrms
726 and extacted signal don't change. However, at all places where
727 raw data is directly accessed (eg. saturation and variation
728 limits in the signal- and pedestal-extraction) the numbers
729 refer still to the data's 16bit range.
730
731 - callisto: The maximum arrival time difference used in the bad
732 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
733 for both, old FADC and MUX-FADC, data.
734
735 - callisto: Be aware that callisto is now calibrating the arrival time
736 in nanoseconds rather than time slices. Also all following tasks
737 have been changed to assume ns units now. If you star data
738 calibrated with an older version it might be necessary to adapt
739 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
740 to obtain optimal results. The plot in the PulsePos tab
741 will now be in ns, too. This might also mean that the Muon
742 analysis in star might not work as perfect as expected as long
743 as old files read in.
744
745 - callisto: The calibration constants of earlier updates got lost
746 somehow. All constants have been updated.
747
748 - star: The PSF is now determined from the profile of the ArcWidth
749 instead of arcwidth/radius. The old way gave to much weight
750 to the bins with low statistics. The reference lines have been
751 updated.
752
753 - star: For speed reasons events suitable for the muon analysis
754 are now also preselected by fConcCOG<0.1 which seems to be a very
755 good preselector for muons.
756
757 - star: is now calculating a new timing parameter the Slope along
758 the major and minor axis of the shower. Therefore a numerical
759 solution of a line-fit is used. To use MHillasExt.fSlopeLong
760 and MHillasExt.fSlopeTrans don't forget to multiply it with
761 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
762
763 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
764 have been removed from MNewImagePar. They have never been good for
765 anything.
766
767 - star: Implemented a new recursive algorithm which is supposed to be
768 faster. Also implemented new cleaning oiptions, which are:
769 + CleanLevel0:
770 The cleaning level above single core pixels can be kept
771 + KeepIsolatedPixels:
772 Define whether single core pixels should be kept
773 + TimeLevel1:
774 The coincidence window in nanoseconds to single used neighbors
775 + TimeLevel2:
776 The coincidence window in nanoseconds to two used neighbors
777 + PostCleanType:
778 MOde in which a time dependent post cleaning should be applied
779 0: No post cleaning
780 1: Require for each used pixels at least one used neighbor
781 within a time-window of CleanLevel1
782 2: Require for each used pixels at least two used neighbor
783 within a time-window of CleanLevel2
784 3: Require first two and second one used neighbor
785 within a time-window of CleanLevel1 and fCleanLevel2
786 respectively
787 + RecoverIsolatedPixels:
788 - recoveres isolated core pixels if they have a used neighbor
789
790 - mars/star: The new default cleaning is:
791 + CleanLevel1: 6.0
792 + CleanLevel2: 3.0
793 + CleanTime1: 1.75
794 + CleanTime2: 1.75
795 + PostCleanType: 3
796
797 - star/ganymed: The old spark-cuts have been replaced by new ones.
798 These new spark cuts have been cross checked with the sequences
799 84720 (before splitter), 101041 (after splitter) and 223539 (new
800 FADCs). In all cases they seperate pretty well, but of course not
801 perfect. Monte Carlos have suggested to tighten the cuts a little
802 bit further at low sizes. This has been done.
803
804 - ganymed: IMPORTANT - The spark cuts have been changed to match
805 all available data more or less well. This might mean that for
806 YOUR data there are still sparks visible.
807 Whenever you do an analysis you have to make sure that NO sparks
808 survive your cuts!
809
810 - ganymed: The old hadronness and size cuts have gotten new indices
811 (10, 11). The old indices 8 and 9 now mean an additional condition
812 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
813 If you want to switch off this cut just move the line far away enough,
814 e.g. by setting c[9] to -500. Please update your ganymed.rc files
815 accordingly!
816 The unit of c[9] is deg. It is the dist at which your cut will
817 cross the slope==0. The unit of the slope is ns/deg. So if
818 you readin files calibrated with an older Mars-version you
819 have to adapt the default value for c[9] to the FADCs:
820 - Multiply by two for the MUX FADCs (run number > 200.000)
821 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
822 - Multiply by 42 for the meaning of life (run number = 200.000)
823
824 - ganymed: The old Cut0 is now called CutQ and is calculated before
825 the source position is caluclated. If you need a quality cut
826 including source dependant data (be very carefull with this!)
827 you have to use Cut0 instead.
828
829 - ganymed: now properly supports three off regions in wobble mode.
830 It will be the default from now on in ganymed_wobble.rc. To change
831 the number of off-regions use
832 NumOffSourcePositions: 1
833 in your ganymed.rc. Also by default no off-theta cut will be done
834 anymore so that you will get a background level higher than the
835 signal level in your ThetaSq plot for ThetaSq>0.2.
836 Due to this be carefull changing the scaling mode away from
837 "None". You will underestimate your signal if your scale interval
838 is not properly set.
839 (Rem: ThetaSqN is no longer needed)
840
841 - ganymed: is now storing the events of all (on- and off-)
842 source positions even in the case of more than one off-source
843 position. This should allow sponde to work properly and the
844 energy estimation is done correctly in all cases (without any
845 "nearest position" trick)
846
847 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
848 with a real pointing model for the starguider is done, calibrated
849 with more than thousand tpoints taken from this date on.
850
851 - ganymed: was broken for Wobble-MCs... fixed.
852
853 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
854 has changed. Note that your old ganymed.rc will be incompatible
855 with the new algorithms! Please check the ganymed.rc files and
856 the class description of MFMagicCuts for more information.
857 It is recommended at the moment to use identical Disp-Parametrizations
858 for on/off- and wobble-mode. If cuts are optimized only
859 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
860 should be optimized. All other values should be kept as they are.
861 If you want to do an anylsis without timing a parameters, you can
862 switch off the timing cuts by seeting parameter 7 to a very small
863 value (eg. -99). To remove the slope parameter from the disp
864 paremtrization set parameter 8 to 0.
865
866 - ganymed: The distribution of observation time versus zenith
867 angle is now shown for off- AND on-data.
868
869 - ganymed: The contents of the source position plot are no longer
870 averaged, thus a lot of (fake) events between the two wobble
871 positions have disappeared.
872
873 - ganymed: There is a new tab "CutT" it contains the VsSize plots
874 with the CutT, whihc is defined in ganymed.rc, applied. It
875 is resonable to use your theta-cut for it, to see if there is
876 something strange (sparks!) in your signal-region.
877
878 - ganymed: To choose a dataset from a collection in a dataset file
879 use the new command line option "--dataset=12345"
880
881 - optim, sponde: should now properly support three off-regions.
882 Just produce your ganymed summary files with three off-regions.
883 optim and sponde will automatically get all off events from
884 all off-regions from this file. Please do not forget to
885 set the scaling in optimwobble.C properly:
886 fit.SetScaleUser(1./3);
887 it is not yet read in automatically (will follow soon).
888 In the case of fixed Scale you can also use
889 cuts.SetThetaCut(MFMagicCuts::kOn);
890 no off-cut needed.
891 Be carefull in case of three off-regions when switching on
892 scale mode. Make sure that the scale interval is set correctly.
893
894 - sponde: sponde.rc and sponde_onoff.rc are now idetical
895
896 - sponde: the resouce files have been rewritten with a lot of
897 comments and a well working parametrization for an energy estimator
898
899 - sponde: In the estimated energy versus monte carlo energy plot the
900 contents where exchanged.... fixed.
901
902 - sponde: the so called "accurate"-mode has been removed. It didn't
903 give any improvement in accuracy, only decreased execution speed.
904
905 - sponde: the so called "simple"-mode has been removed. It didn't
906 give any improvement in simple.
907
908 - sponde: the so called "refill"-mode has been removed. It was anyhow
909 not implemented.
910
911 - sponde: now checks whether the theta distribution of your on-data
912 and the theta-distribution of your Monte Carlo sample (after
913 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
914 sample is incomplete) execution is stopped. Execution can be forced
915 using the new option --force-theta. Use this option with care!
916
917 - sponde: Proper collection areas can now be constructed also from
918 Monte Carlo samples generated with different maximum impact
919 parameters. Note that in previous version you neither got
920 a warning or failure, nor was there any obvious sign that the
921 collection area was overestimated due to usage of files with
922 different maximum impact parameters.
923
924 - sponde: If MC files with different lower energy limits are used
925 the primary MC spectrum is artificially completed down to the
926 lowest energy used at all. WARNING: that this gives correct
927 collection areas ONLY if none of the events in this region would
928 survive your cuts at all.
929
930 - sponde: the output file now contains more information about
931 the spectrum (eg. the full 2D collection area histogram).
932 Note, that this information can only be written to the file
933 if it is stored automatically via command line argument.
934 If you only store the status display from within the display
935 the information is lost.
936
937 - sponde: added a new tab "Disp". It shows the residual of the disp
938 (Disp-Dist) versus several parameters and it is meant to judge the
939 quality of the disp estimator. In the ideal case the residual is zero
940 and doesn't depend on any variable. The tab is displayed after
941 CutQ and Cut0.
942
943 - sponde: added a new tab "Energy". It shows the residual of the
944 energy (lg(estimated energy)-lg(monte carlo energy)) versus
945 several parameters and it is meant to judge the quality of the
946 energy estimator. In the ideal case the residual is zero
947 and doesn't depend on any variable. In reality even a good estimator
948 can show residuals versus Monte Carlo energy. The tab is displayed
949 after all cuts.
950
951 - sponde: added a new tab "EventDist" showing the unweighted real
952 absolute number of events of your sample after cuts. This tells
953 you how many events with this energy you had in your MC files.
954 The same information you get from the error bars of the weighted
955 histograms, but this is less intuitive.
956
957 - sponde: The spectrum plots now show the crab- and 1553-spectrum
958 for comparison. It is not meant to show these curves in
959 publications, they are only for production.
960
961 - sponde: The OriginalMC tree with the events produced by corsika
962 is now processed only once
963
964 - sponde: Finally fixed most annoying bug, which has effected the
965 last bin of the collection area. It was the problem that binnings
966 of root histograms are from 1 to n (included) but there was a C-like
967 loop in sponde from 0 to n (excluded). Now the loop also includes
968 correctly under- and overflow-bins. The worse thing with this is,
969 that for the events in the highest bin not only the bin-content
970 was wrong, but also the weights applied to these events, which could
971 in pricipal effect also other parts of the distribution (eg. due
972 to energy estimation). Fortunately it effected only a few events
973 in most cases.
974
975
976
977 *** Version 1.2 (2007/05/14)
978
979 - database: The database now has two new values Unsuitable50 and
980 Unsuitable01. They express the number of pixels which are
981 unsuitable for more than 50%, respectively more than 1%, of
982 all calibrated event. It is a more accurate number than the
983 previously used numbers, because they only take the first
984 calibration (ignoring the interleaved calibrations) into account.
985
986 - database: The database now has two other new values UnsuitableMax and
987 DeadMax. They express the maximum number of pixels which were
988 unsuitable, respectively dead, during the sequence. Because
989 of high pedestal rms (cars passing) a few events with very high
990 numbers of unsuitable pixels can happen. Not to suffer from this
991 effect we don't take the highest 0.1% of the numbers into account.
992
993 - general: fixed a bug which caused callisto and star to stop working
994 properly because the callisto output was currupted
995
996 - general: a script called scripts/makemovie has been added which
997 simplified the process of producing several movies from a single
998 sequence with different setup.
999
1000 - callisto: Some more code cleanup. Started to remove old obsolete
1001 code from cvs.
1002
1003 - callisto: The extraction of the pedestal with the extractor was
1004 not random. It seems that extracting at one position is still biased
1005 (for example in the first or last slices we could still suffer from
1006 switching noise) Now it is completely random.
1007
1008 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1009 pedestal files) individual pixels could be skipped due to high
1010 variations. This was already the case for the pedestal extraction
1011 from the lo-gains since the beginning and properly handled
1012 there, but was introduced in the extraction from the pedestal files
1013 a while ago. To calculate the average value it was still divided
1014 by the number of events procesed not by the number of summands
1015 really summed. This let to a pedestal which was a tiny amount too
1016 small (for a few piels in the order of 0.1%). This led to an slightly
1017 positive offset of the randomly extracted pedestal for a few pixels.
1018 I doubt that this has a big effect on the result, because the effect
1019 on the individual numbers is quite small. Due to this it is suggested
1020 that you rerun your calibration to make sure you are without any
1021 avoidable bias.
1022
1023 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1024 the median rms of the absolute arrival time and expressed in significance
1025 levels. This replaces the old meaning of an abolute upper limit. An
1026 absolute upper limit doesn't make much sense, because in our data
1027 all arrival times are shifted at the same time (in fact it might be
1028 a shift of the artificial trigger w.r.t. to the light flash).
1029
1030 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1031 of the number of unsuitable pixels over the whole sequence. This
1032 is usefull mainly to judge if an intermediate calibration had
1033 problems.
1034
1035 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1036 of the number of dead pixels over the whole sequence. Dead pixels
1037 in this context are unmapped pixels, i.e. pixels which could not
1038 be interpolated, and thus are ignored in the further analysis.
1039
1040 - callisto: It is now possible to use the position of the maximum
1041 of the spline as arrival time instead of the leading edge even
1042 when using the integral for the signal. Therefor set the extraction
1043 type to kIntegralRel ("IntegralRelative") and the relative height
1044 ("HeightTm") to -1:
1045 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1046 MJPedestalC1.ExtractSignal.HeightTm: -1
1047
1048
1049
1050
1051 *** Version 1.1 (2007/04/27)
1052
1053 - general: The new class MGeomCamDwarf contains the camera geometry
1054 for our prefered Dwarf camera and can be used to create general
1055 geometries of roundish or hexagonal cameras.
1056
1057 - mars: The default cleaning is now abolute 8.5/4.0.
1058
1059 - mars: The resource file mars.rc now contains examples for MUX data
1060
1061 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1062 data containing only 10-bit information is still cooked down to
1063 8-bit, by cutting away the lowest 8-bit.
1064
1065 - merpp: When reading raw data the data is now stored in a single
1066 array. The lo-gain array is obsolete. The interface stays the same.
1067
1068 - callisto: To process the new MUX data use the resource file
1069 callisto_mux.rc
1070
1071 - callisto: The -root and -raw options to read merpped raw data have
1072 been removed
1073
1074 - callisto: If the -mc option is given the sequence-name can now be
1075 replaced by the MC sequence number
1076
1077 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1078 -mc option can now be omitted
1079
1080 - callisto: Started further simplification by removing obsolete
1081 dependancies on MCalibIntensity*Cams.
1082
1083 - callisto: removed unsused intensity calibration from MJCalibration
1084 for further simplification
1085
1086 - callisto: for simplification removed references to
1087 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1088 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1089 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1090 (this should at minimum change nothing at all, and at maximum
1091 improve thing if these containers where somewhere not handled
1092 properly)
1093
1094 - callisto: Added the option to write an event movie. Please use
1095 this option with care (huge files) but exessively to understand
1096 our events. For further documentation please refer to the
1097 IACT wiki
1098 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1099
1100 - callisto: Improved binning for the pulse position check histogram
1101
1102 - callisto: The code calculating the pulse position checknow takes
1103 the pedestal into account
1104
1105 - callisto: The arrival time is now stored with full precision this
1106 helps to get rid of artefacts in histograms. For the signal this
1107 is not necessray because it is displayed in log-scale anyhow
1108
1109 - callisto: Fixed a problem with internal exclusions. Pixels which
1110 have once been marked as unsuitable didn't get the necessary
1111 histograms filled anymore to be rechecked with each interleaved
1112 calibration.
1113
1114 - callisto: The relative arrival time resolution (the rms of the
1115 relative arrival time offset) is now checked against its
1116 median and the median deviation, instead of the average
1117 plus an absolute offset.
1118
1119 - callisto: The relative arrival time offset is now calculated
1120 w.r.t. its median not w.r.t. to an artificial reference pixel.
1121
1122 - callisto: The relative time calibration now marks pixels with
1123 outlaying offset as unsuitable
1124
1125 - callisto: The interleaved relative time calibration has been switched
1126 on. The advantage is that pixels which are marked as outliers
1127 now can recover. An improvement over time is not expected, because
1128 the relative time calibration seems stable.
1129
1130 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1131 option can now be omitted.
1132
1133 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1134 or the option "-mc" is specified as default the monte carlo datacenter
1135 paths (/magic/montecarlo/...) are used if not overwritten in the
1136 dataset file.
1137
1138 - ganymed: The output files now contain run- and event-number for all
1139 events, accessible as RunNumber.fVal and EvtNumber.fVal
1140
1141 - ganymed: Added a plot showing the source position in the camera also
1142 for wobble mode
1143
1144 - ganymed: In addition to the existing task which can be setup to
1145 be executed after Cut1 a final task called "EstimateEnergy"
1146 has been added, executed before writing the final output
1147 (ganymed00000000.root). The task setup in all three cases
1148 can be choosen individually. (For all three(!) cases you
1149 can for example choose MRanForestCalc. For examples see all
1150 sponde*.rc and all ganymed*rc)
1151
1152 - ganymed: If a container "MEstimatedEnergy" is found in the
1153 parameter list (eg. because it was setup by MEstimateEnergy)
1154 it will be written to the output file.
1155
1156
1157
1158 *** Version 1.0 (2007/02/16)
1159
1160 - database: Website to plot values from the database has been added.
1161
1162 - database: The rate of spark events as found by star is now kept
1163 and the rate after cleaning is now with spark events subtracted
1164
1165 - general: The changes to the interpretation of phrases lead to
1166 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1167
1168 - general: Added example files how you can create your own calendar
1169 (eg. as christmas present) with Mars. Just run
1170 root macros/tutorials/calendar.C
1171
1172 - general: Added a possibility to display grouped data in the plotdb.C
1173 macro (and similar macros). This allows to plot hourly, nightly,
1174 weekly, monthly and yearly averages.
1175 For more details see the plotall function of the macro
1176
1177 - general: fixed the error display of the camera display. It showed
1178 wrong results.
1179
1180 - general: fixed a memory leak when reading many MStatusDisplays
1181
1182 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1183 between a spherical and a parabolic mirror
1184
1185 - callisto: We have a new pulse position check which takes the properties
1186 of the extractor automatically into account. So no need to set
1187 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1188 left is done. If possible the lo-gain extraction start and hi-gain
1189 extraction end is changed accordingly. If no proper extraction range
1190 can be set (hi-gain too much to the left) an error is raised.
1191
1192 - callisto: New swapped pixels have been found and corrected
1193
1194 - callisto: Redone the signal extraction this includes:
1195 + Unified the algorithms to extract the pedestal for all pedestal
1196 extractions done
1197 + Unification of hi- and lo-gain into one array
1198 + Unification of hi- and lo-gain extraction for Spline and
1199 Digital Filter (means now exactly the same algorithm is used,
1200 not a copy-and-pasted one)
1201 + Store pedestal subtracted data in a common place
1202 + Improved extraction algorithms. If the algorithms search a
1203 maximum but don't find one they don't return the maximum anymore
1204 + Improved the extraction such that a information for signal
1205 and time which is consistent is returned
1206 + replaced the numerical spline with a (not slower) analytical
1207 solution
1208 + Lowered the saturation limit from 250 to 245 to make sure that
1209 we are far away in all pixels from problems with the clock-noise
1210 + The start of the lo-gain extraction is calculated from the hi-gain
1211 arrival time. In case of saturation an estimation is used.
1212 + the hi-gain window was extended to slice 16. This allows extraction
1213 of very late pulses in single pixels or of huge hadron showers.
1214 + Now uses the lo-gain extraction range for pedestal extraction,
1215 not the hi-gain range in the lo-gain
1216
1217 - callisto: New hi-/lo-gain calibration constants have been produced
1218 for all periods from the statistic of the whole period. They are
1219 now used automatically depending on the periods. The old constants
1220 where deviation in avarega about 2%-3%. The constants are very
1221 stable from period to period (<<1%) except for exchanged channels.
1222 In a few cases the constants used so far were off by 1%-2% (maybe
1223 temperature effects?)
1224
1225 - callisto: To gain obsolete space we do not write the
1226 MPedestalFundamental anymore. Also calibration and bad pixel
1227 treatment is not done for it anymore because it has never been used.
1228
1229 - callisto: Fixed a bug in the seuqence handling which caused the
1230 light condition to be ignored
1231
1232 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1233 basically the same as "Cleaned" but the distribution devided into
1234 the events fullfilling a spark cut or being rejected by it.
1235 This cut can be changed from star.rc (see example inside) by
1236 the "SparkCut" directive
1237
1238 - star: Star displays now the average individual pixel-rate (IPR) versus
1239 time and the average discriminator threshold (DT) of all pixels.
1240
1241 - optim: fixed a problem with the optim-macros which was due to a bug
1242 in the new phrase parsing
1243
1244 - ganymed: To get a nice FalseSource plot (instead of the all-information
1245 debug plot displayed as a standard plot) use the context menu
1246 somewhere between the two upper plots, click on "DrawNicePlot"
1247 and enjoy the result. (It is the same context menu which contains
1248 the other options)
1249 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1250
1251 - ganymed/optim/train: The cut program, trainings- and optimization
1252 macros could run with less files found than expected from the
1253 sequence-files. No the execution is stopped in this case.
1254
1255 - ganymed: now stores the dataset in the output file with all information
1256 contained (as sequence number, sequence path, data path) so that the
1257 used dataset file can be recreated complete from the output
1258
1259 - sponde: now also allows the uasge of random forest
1260
1261 - sponde: added a plot showing the cut efficiency
1262
1263 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1264 errors (eg. effecting the collection area) because the errors of the
1265 two histograms were swapped in the calculation, which makes a difference
1266 in the case the histograms contains weighted events. Aditionally the
1267 totalarea was incorrectly taken into account, which results in too small
1268 errors, which makes a difference at low statistics were the errors
1269 or the collection area dominate.
1270
1271
1272
1273 *** Version 0.10.3 (2006/10/23)
1274
1275 - database: Implemented ObservationMode flag in websites.
1276
1277 - database: For sequences there is now also the stoptime available on the
1278 websites.
1279
1280 - database: Removed ManuallyChanged flag from sequence-info websites,
1281 as it is not needed anymore with the new sequence building algorithm.
1282
1283 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1284 Class for calculation of confidence intervals (upper limits).
1285 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1286 Please read the class instruction of TRolke for more information.
1287
1288 - general: The programs now return 0xfe if the requested resource file
1289 doesn't exist.
1290
1291 - general: Errors comming from root itself are now not output to
1292 stderr anymore but to our default (colored) log-stream.
1293
1294 - general: Changed the interface to TFormula such that now everything
1295 is parsed by TFormula, which should allow to use phrases even
1296 without paranthesis correctly parsed.
1297
1298 - callisto: replaced the AdHoc number of effective integration slices
1299 in the digital filter by an average of the correct number, averaged
1300 over all possible set of weights. This also gives correct numbers
1301 for the lo-gains which were totally wrong before.
1302
1303 - callisto: drastically reduced memory consumption by not storing
1304 all intermediate calibration results in memory anymore (we might
1305 write them into a file in the future)
1306
1307 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1308 debug plot displayed as a standard plot) use the context menu
1309 somewhere between the two upper plots, click on "DrawNicePlot"
1310 and enjoy the result. (It is the same context menu which contains
1311 the "DrawAll" option)
1312 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1313
1314
1315
1316 *** Version 0.10.2 (2006/10/15)
1317
1318 - general: changed the building of the sequence files such, that
1319 the source-/project name in case of wobble-sources is not the
1320 source/project of the first data run anymore but the new generalized
1321 wobble source/project
1322
1323 - general: Added some functions to MAstro to calculate sun and
1324 moon properties
1325
1326 - general: Added two new macros (starvisday.C and starvisyear.C)
1327 which allow to plot the visibility of several stars in one day
1328 or of one star along one year
1329
1330
1331
1332 *** Version 0.10.1 (2006/10/11)
1333
1334 - general: HTML logging output was distorted... fixed.
1335
1336 - general: Changed the writing of the sequencefiles such that only
1337 as many pedestal files as giving at least 1000 pedestal events which
1338 are nearby the first calibration run are used as pedestal runs
1339
1340 - sponde: In the calculation of the collection area(s) and the
1341 distribution for MOnte Carlo and estimated energy the error
1342 calculation was wrong because root didn't take the errors
1343 properly into account... fixed.
1344
1345
1346
1347 *** Version 0.10 (2006/10/10)
1348
1349 - general: all executables now check consistency of the root version
1350 installed with the root version used for compilation. The return
1351 code in this case is 255.
1352
1353 - general: The algorithm to build seqeunces has been redesigned
1354 completly. It is now more flexible in terms of a resource file
1355 resources/sequences.rc which can be used to partly overwrite
1356 the default algorithm and defined the important part of the
1357 algorithm. It also takes correctly into account several ways
1358 of taking wobble-data. Currently the new algorithm doesn't take
1359 the number of pedestal events anymore into account (so a sequence
1360 could have much less than 1000 pedestal events and data runs are
1361 no-more used instead)
1362
1363 - general: a lot of small changes to make the code compatible with
1364 root 5.12/00 and gcc 4.1
1365
1366 - general: Fixed some warnings thrown if more warnings are switched
1367 on in the compiler
1368
1369 - general: Added a function to MMath which returns the Median of
1370 the distribution abs(y[i]-median) but at 68:32 division instead
1371 of 50:50, which is somehow the median counterpart of the rms.
1372
1373 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1374 even if they are compressed with gzip (recommended compression
1375 is with "-1")
1376
1377 - showplot:
1378 + batch mode creation of image files now works with root 5.12/00
1379 + added support for writing bmp (though it never produces
1380 bmp which can be read by programs like xv or gimp)
1381 + added support for xml
1382 + added new option to start the display with a different size, by
1383 --display-width=nnn or --display-height=nnn
1384 + added options to define the canvas size when the display is started
1385 --canvas-width=nnn or --canvas-height=nnn
1386 the option can also be used for batch-mode conversion
1387 + added an option which automatically fits the display size to the
1388 desktop-size: --auto-size
1389
1390 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1391
1392 - merpp: allow the reports to have 1000ms due to a bug in the camera
1393 program.
1394
1395 - callisto: New swapped pixels have been found and corrected. For
1396 details see MRawRunHeader::FixAssignment()
1397
1398 - callisto: Callisto now raises an error if one of the input files could
1399 not be opened.
1400
1401 - callisto: In some rare cases it could happen that in the signal
1402 extraction of the digital filter the extractor returned nonsense
1403 results due a wrong initializion of a variable (this happens in
1404 cases in which the extracted signal is exactly zero or the
1405 digital filter couldn't slide because of a too small extraction
1406 window, which could happen in the lo-gain extraction)
1407
1408 - callisto: The lo-gains have been marked as valid in some cases
1409 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1410 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1411 smaller than the number of slices (fLoGainWindowSize) needed
1412 by the lo-gain extractor
1413
1414 - callisto: Updated absolute calibration constants (muon calibration)
1415
1416 - callisto: fixed a bug which caused the hi-gain saturation not
1417 to be handled properly in the spline (the position of the
1418 saturation was calculated incorrectly)
1419
1420 - callisto: fixed a bug which gave weird results if hi- _and_
1421 lo-gain could not be extracted properly. In some cases hi-
1422 and lo-gain have not been extracted at all and the random result
1423 got calibrated. In other cases the hi-gain was saturating and the
1424 lo-gain has not been extracted. For this a completly arbitraty
1425 scale factor was applied to the result from extracting the
1426 charge of the saturating hi-gain.
1427
1428 - callisto: improves handling of extracted signal if lo- and/or
1429 hi-gain could not be extracted properly. If no appropriate
1430 calibration of either the signal or the arrival time is possible
1431 the pixel is now markes as unsuitable instead of estimated.
1432
1433 - callisto: Fixed a problem in the spline extraction which gave
1434 weird results if the signal was extracted from the first (and
1435 highest) slice (as a workaround extraction from the first
1436 slice has been forbidden)
1437
1438 - callisto: Fixed a bug regarding the use of the QE which doesn't
1439 effect the result because the default is used anyhow.
1440 (The bug was there since 14/07/2005)
1441
1442 - callisto: Changed the default for fgLoGainStartShift to -2.4
1443
1444 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1445 factors to be always 10 for all pixels as soon as the first
1446 calibration update has happend.
1447
1448 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1449 was off by more than one slice (which gives wrong values for
1450 pixels which have saturated the hi-gain) This was a problem
1451 mainly for timing studies, not so much for the automatic standard
1452 analysis. Also the values for the Spline have been changed slightly:
1453 + Digital Filter from 1.70 to 0.95
1454 + Spline from 1.39 to 1.30
1455 The numbers were sorted out by an extensive test in the
1456 test-database.
1457
1458 - callisto: Removed the tab showing the average calibrated arrival
1459 time. It never gave useful information.
1460
1461 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1462 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1463 and both were extracted because the hi-gain was above the
1464 LoGainSwitch.
1465
1466 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1467 lo-gain pulse position (after application of LoGainOffset, which
1468 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1469 have saturated and both were extracted because the hi-gain was above
1470 the LoGainSwitch.
1471
1472 - callisto: After extensive tests a new threshold level for determination
1473 of the pulse position has been found at 50phe. This is due to the
1474 fact that for lower pulses the arrival time changes its average
1475 behaviour dramatically. It tends to the average of the extraction
1476 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1477
1478 - callisto: Added two more plots to the calibration part. The average
1479 extracted signal and the average extracted arrival time as
1480 extracted by the signal extractor (This can help debugging problems
1481 because it doesn't involve a fit)
1482
1483 - star: changed the fit for the effective on time such that initial
1484 values are calculated automatically now instead of using build
1485 in values. This makes the fit more indepedant of the underlaying
1486 rates. With a test of ~350 sequences in the test database it could
1487 be shown that the new fit gives the same result +/-1sek.
1488 The highest deviation was +5s the lowest -10s. You can now control
1489 the bahaviour with two resource values:
1490 MHEffectiveOnTime.FistBin: 3
1491 MHEffectiveOnTime.NumEvents: 12000
1492 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1493 from the resulting gamma candidates
1494
1495 - star: The Center histogram in MHHillas is now by default displayed
1496 with the colz draw-option
1497
1498 - ganymed: now produces valid error codes if failed
1499
1500 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1501 with the option "hadronness" instead of "area" or "both" if
1502 you want to use both cuts. The hadronness cut includes a fixed
1503 cut in hadronness (index 8) and a fixed cut in size (index 9).
1504
1505 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1506 the M3Long of the anti source to be not properly evaluated
1507 (actually is was evaluated as a unique random number) in case
1508 of optimization with anti-theta cut switched on. This might have
1509 lead to improper, but not necessarily wrong, optimization results.
1510
1511 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1512 how to use random forest
1513
1514 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1515 ganymed_onoff.rc. Seems to be unintentional that they were different.
1516
1517 - sponde: Since the introduction of the possibility to define a
1518 normalization energy instead of using the integral the default
1519 was not using the integral anymore but a normalization energy of
1520 1GeV. It is now the integral again.
1521
1522 - sponde: Fixed a problem in the weighting which did not allow
1523 a MC slope of -1.
1524
1525
1526
1527 *** Version 0.9.6 (2006/05/24)
1528
1529 - general: changed the binning of the azimuthal profile of the camera
1530 such that it is aligned with the 60deg boundaries.
1531
1532 - merpp: better handling of problems with the TH, TD part of the
1533 CC-REPORT for files older than 200507190 and 200412210
1534 respectively
1535
1536 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1537
1538 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1539
1540 - callisto: if an arrival time is extracted outside the fadc range is
1541 was set to the boundary before. Now a random number is assigned
1542 instead to avoid unfortunate coincidences of arrival times just
1543 by this arbitrary value.
1544
1545 - callisto: added a new option to callisto.rc which allows
1546 to set the maximum arrival time difference allowed for the
1547 badpixel algorithm to determin whether a pixels belongs to a shower:
1548 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1549
1550 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1551 to 0.9 as suggested by Stefan due to a recent study on the fraction
1552 of pixels surviving the image cleaning
1553
1554 - callisto: switched off error in case of "pulse is too much to the left"
1555
1556 - callisto: The extraction window is not adapted anymore. This means that
1557 the pulse is extracted from the full range. The draw-back is that the
1558 background (pedestal) will become slightly higher. Switching on/off
1559 the PulsePosCheck in the callisto.rc only effects filling the
1560 histograms.
1561 WARNING: If the pulse is too much to the left data is calibrated!
1562 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1563 in the database to make sure that your data is valid!
1564
1565 - star: Show also the number of stars correlated correctly by the
1566 starguider
1567
1568 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1569 than one off-source region in wobble-mode. To use it add the following to
1570 your ganymed_wobble.rc:
1571 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1572 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1573 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1574 + Cut1.ThetaCut: None
1575 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1576
1577 - ganymed: in the case the latest report is older than a default (currently
1578 one minute) and the current report will be skip the starguider
1579 correction and calibration will be reset. The maximum age can be
1580 setup from ganymed.rc by (minutes):
1581 MPointingDevCalc.MaxAge: 1.5
1582
1583 - ganymed: A first implementation showing all size-bins for the theta-sq
1584 resp. alpha-plots in a single tab automatically
1585
1586
1587
1588 *** Version 0.9.5.1 (2006/05/05)
1589
1590 - general: Added a new option "zdiff" to the Makefile which runs
1591 "cvs diff" as "make diff" would do, but with compression
1592
1593 - general: accelerated MTFillMatrix (used for eample in all training
1594 and optimization macros) by skipping some obsolete calles in the
1595 eventloop the first and second loop could be accelerated by ~20%
1596
1597 - general: Added a missing feature in the MFilterList class which
1598 prevented MFEnergySlope from working correctly in trainenergy.C
1599
1600 - general: Accelerated the random forest training and usage a bit
1601
1602 - merpp: Adapted to new raw data file format version 6
1603
1604 - merpp: fixed a problem with reading the starguider reports
1605 after 6.3.2006
1606
1607 - callisto: At some times six pixels had to be exchanged manually in the
1608 data. If the pixels to be swaped are both not found, an error was raised
1609 and calibration was stopped. Now it is assumed they are intentially not
1610 mapped and the Error has been changed to a Warning.
1611
1612 - star: Added new image cleaning based on the arrival time of the shower.
1613 The new cleaning can be accessed using the parameter "Time" instead of
1614 the the old one (like "Absolute) in the star.rc-file.
1615 Recommended parameters:
1616 + MImgCleanStd.CleanLevel1: 8.2
1617 + MImgCleanStd.CleanLevel2: 5
1618 + MImgCleanStd.CleanRings: 2
1619 + MImgCleanStd.KeepSinglePixels: No
1620
1621 - star: Simplified the calculation of the effective on time. By letting
1622 the fit start in the third bin the result should become more stable.
1623 The fit quality is now ignored for the theta-plot which is not used
1624 in the analysis later. Still better pre-cut which, for example,
1625 remove events triggered by car-light (rate changing on a short
1626 time-scale) are missing.
1627
1628 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1629 for optimization (kWeakSource) which is suggested by the Berlin
1630 people for weak sources.
1631
1632 - macros: plotdb.C:
1633 + if no dataset and no time-interval is given only sequences with
1634 an effective on-time above five minutes are plotted anymore
1635 + added a new tab "RelTime" displaying the relative on-time
1636 (effective on-time divided by the observation time)
1637
1638 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1639 the optimization became a lot faster
1640
1641 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1642 To display them just delete the pads displayed on top.
1643
1644 - ganymed: fixed a bug which could cause strange behaviour in wobble
1645 mode if no starguider information was available due to an incorrect
1646 initialization of the starguider calibration
1647
1648 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1649 be changed from within the plot. It can also be setup from the
1650 resource file using:
1651 + MHDisp.fScaleMin: 0.325
1652 + MHDisp.fScaleMax: 0.475
1653
1654 - ganymed, showplot: Fixed a problem with the fit to the off-data
1655 (HistOff) which could cause a time lag or an inifinite loop.
1656 The bug did not effect the results at all.
1657
1658 - sponde: Added a new tab showing the effective collection area after
1659 trigger (including the software trigger)
1660
1661 - sponde: MMcSpectrumWeight has a new option which allows to define
1662 the scaling factor not by the integral of the events but at
1663 a defined energy:
1664 e.g. MMcSpectrumWeight.NormEnergy: 200
1665
1666 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1667 eventloops the loop could be accelerated by ~20%
1668
1669
1670
1671 *** Version 0.9.5 (2006/03/13)
1672
1673 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1674 and added the standard Disp-parametrization
1675
1676 - macros: added a new macro datacenter/macros/plotstat.C allowing
1677 to plot statistics about the data processing
1678
1679 - macros: added a new macro to plot the muon correction coefficients
1680 versus period (macros/plot/mucal.C)
1681
1682 - showplot: path inflation for ganymed files was broken
1683
1684 - callisto: Fixed an important bug. When the number of saturating pixels
1685 were calculated the bad pixel information already available from the
1686 calibration was ignored. This yields wrong values in case pixels
1687 are broken and saturate all the time or randomly.
1688
1689 - callisto: Updated Muon calibration constants. Spline data now also uses
1690 different values for different periods
1691
1692 - star: The time-evolution shown in the effective on-time plot now displays
1693 the axis range (if there are no holes it should be similar to the
1694 effective on-time)
1695
1696 - star: Added two new image parameters:
1697 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1698 the three pixels next to the center of gravity and the size
1699 + MNewImagePar.fConcCore: The ratio of the signals of all
1700 pixels inside or touching the ellipse and the size
1701
1702 - ganymed: now stops in requested source isn't found in catalog file
1703
1704 - ganymed: Many improvements to the phi-plot in wobble mode:
1705 + with a template the ideal background is displayed
1706 + a possible camera inhomogeneity is taken into account
1707 + the anti theta cut is better supported
1708 + the phi cut is automatically calculated from the theta cut
1709 See the examples in ganymed_wobble.rc for more details.
1710
1711 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1712 times the bin-width instead of the absolute energy
1713
1714 - ganymed: New cuts for on/off and wobble mode
1715
1716 - ganymed: The smearing of the False Source plot has been increased
1717 to 0.06
1718
1719 - ganymed: The starguider calibration can now be changed from the
1720 resource file.
1721 See the examples in ganymed*.rc for more details.
1722
1723 - ganymed: added a new option for on-/off-observations
1724 MJCut.RandomSourcePosition
1725 If switched on the distribution of observation time of the source
1726 position in the camera is calculated from the on-data and randomly
1727 applied with this distrbution to the off-data.
1728
1729 - ganymed: by skipping some obsolete calles in the eventloop the
1730 first and second loop could be accelerated by ~20%
1731
1732 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1733 position in the off-data randomly according to its distribution in the
1734 on-data.
1735
1736
1737
1738 *** Version 0.9.4.3 (2006/02/13)
1739
1740 - general: Fixed a bug in most of the programs which prevented the
1741 compile date in the startup message to be displayed
1742
1743 - general: Simplified program calls. The following abbreviations
1744 are now possible:
1745 showlog callisto 55599
1746 showplot signal 55599
1747 star 55599
1748 callisto 55999
1749 ganymed 2
1750 In this cases the corrsponding root-, log-, sequence- or dataset-
1751 filename is automatically compiled using the default datacenter
1752 paths ("/magic/*")
1753
1754 - general: Fixed a long outstanding bug which made axis tick marks
1755 disappear if MDataFormula was used (eg. abs(x))
1756
1757 - general: Updated MMath with new functions to calculate the results of
1758 a exponential, logarithmic and powerlaw fits analytically.
1759
1760 - general: Updated some macros with comments:
1761 + macros/optim/optimdisp.C
1762 + macros/optim/optimenergy.C
1763 + macros/optim/optimwobble.C:
1764
1765 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1766 files) now allows adding a pre-cut like in the optimization. E.g. this
1767 is useful to perform g/h-separation cuts before training the random
1768 forest.
1769
1770 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1771 correctly assigned in the raw data assignement table. A fix to correct
1772 the assignment tabel have been implemented.
1773
1774 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1775 by 90, 180 and 270 deg.
1776
1777 - general: the macro plotdb.C now allows to highlight sequences belonging
1778 to a datset. For more details see the descritions in the macro.
1779
1780 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1781 of the display, it gave wrong results espacially for big sizes.
1782 Now the embedded canvas should always have a ratio width/height=3/2.
1783 The "Size" options have been updated with values fitting the 3/2
1784 size ratio.
1785
1786 - RanForest:
1787 + Updated the random forest classes to support also the
1788 regression method implemented by Thomas H.
1789 + added new tutorial macro how to train the random forest
1790 for energy estimation (macros/optim/rfenergyest.C)
1791 + new classes to train the random forest (still in development)
1792 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1793 + new tutorial macros for random forest training in macros/train
1794 trainenergy.C, traindisp.C, trainseparation.C
1795
1796 - mars: now allows to setup a cut in the resource file mars.rc to choose
1797 the events to be displayed, eg:
1798 Cut.Condition: {0} && {1}
1799 Cut.0: MHillas.fSize>100
1800 Cut.1: MHillas.fSize<900
1801
1802 - merpp: Made aware of the new .rep format 200510250. This includes
1803 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1804 the discriminator thresholds (MCameraTD) and the disciminator
1805 delays (MCameraTD). All of them come with the CC report and are therefor
1806 written to the CC tree.
1807
1808 - callisto: fixed a bug in the calculation of the arrival times in
1809 the Digital Filter. They were all shifted by the same amount
1810 fHiGainFirst. This caused an offset in the order of the position of
1811 the left border of the extraction window in the times calculated
1812 from high-gain and from low-gain. The bug effected only the absolute
1813 arrival times. The bug was there since 30.1.2005.
1814
1815 - callisto: Changed the ExtractionWindow for the pulse position check
1816 such that the camera inhomogeneity becomes as less as possible and
1817 comparable to the pulso position check switched off. More details
1818 on the study will be given at our result web-page.
1819
1820 - ganymed: ganymed.rc, ganymed_onoff.rc:
1821 changed to new cuts trained with 1ES1218 and Crab-data
1822 for maximum sigma*log10(excess)
1823
1824 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1825 a new option was implemented to estimate Disp (CalcDisp)
1826
1827 - ganymed: Implemented two new options which allow
1828 to overwrite the default path to search for the sequence files
1829 --ins=/magic/sequences
1830 and where to search for the image data
1831 --ind=/magic/data/star
1832
1833 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1834 dx/dy from the resource file by
1835 MSrcPosCorrect.Dx
1836 MSrcPosCorrect.Dy
1837
1838 - ganymed: fixed reading the source catalog. Only as many chars
1839 as the requested source name had were compared (If a source
1840 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1841 were requested it could happen that the coordinates of
1842 "1ES1218" were read) The source coordinates are now printed
1843 in addition to its name to the logging output.
1844
1845 - ganymed: changed the background fit in the case of a ThetaSq function
1846 from a polynomial to a exponential, this should give a big improvement
1847 for on-only analysis'
1848
1849 - ganymed/sponde: Calculation of the error of single size-/energy-
1850 bins now uses Li/Ma (5) instead of LiMa (17)
1851
1852 - sponde: Added a plot E^2*dN/dE
1853
1854 - sponde: The energy estimator plot should now show values like
1855 they are commonly used.
1856
1857 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1858 (a powerlaw with cutoff didn't work before)
1859
1860
1861
1862 *** Version 0.9.4.2 (2005/10/01)
1863
1864 - general: added new tutorial macro macros/tutorials/threshold.C:
1865 how to calculate the threshold
1866
1867 - general: added a new game. Start it from the interpreter with
1868 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1869 and MagicReversi)
1870
1871 - general: neighbor pixels in MGeoms are now sorted clockwise
1872
1873 - merpp: made aware of new format 20050829-0
1874
1875 - callisto: New scale factors from muon analysis, stored in new
1876 resource file resources/calibration.rc
1877
1878 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1879 the eventloop if something went wrong. This is necessary for the
1880 automatic processing
1881
1882 - callisto: Implemented a new treatment for the time information
1883 developed by S.Ruegamer, this should give much better response than
1884 the old very primitive algorithm. This is especially important
1885 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1886 treatment was buggy! As neighbor pixels to interpolate the
1887 arrival times always the pixels 0 to 5 were taken)
1888
1889 - callisto: In addition to the new treatment of arrival times the
1890 decision of the treatment whether a pixel contains shower
1891 information or not is used to improve the signal interpolation
1892 further. Previously interpolated pixels showed a non-zero signal
1893 do the peak searching signal extractors. Having a signal pixel
1894 beside raised the signal above the cleaning level. Thus the
1895 pixel survived cleaning to often but with a too low mean signal.
1896 By replacing empty pixels with a gaus (mean and rms from the
1897 corresponding Area entries in MPedPhotCam) this effect can
1898 be supressed.
1899
1900 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1901 got lost when the events were stored by the calibration... fixed.
1902 (This was no problem for normal image cleaning because the pixel
1903 content was artificially set to 0 not surviving standard cleaning
1904 algorithm)
1905
1906 - callisto: Fixed a bug which caused the random and peak-search pedestal
1907 extracted with an extractor to be exchanged for the first (roughly)
1908 500 events (*Extractor and *ExtractorRndm).
1909 (They were simply exchanged in callisto.cc) This bug might have been
1910 introduced in Mars 0.9.4 when the order of calculation of the two
1911 types of pedestal in callisto got exchanged. The bug only effects
1912 the first seconds of data of each sequence.
1913
1914 - star: Taking the arrival time of Muons into account the calculation
1915 of the parameters could be made independant of the noise
1916 (pedestal rms). The dependance was due to the bias of the peak search
1917 extractor. Now only a ZA dependamcy is left which is not yet fully
1918 understood.
1919
1920 - ganymed: The sequences were still not sorted correctly in any case,
1921 because they were sorted by the full qualified path name. Now they
1922 are sorted by their sequence number.
1923
1924 - ganymed: new values for the spark-event-cut
1925
1926 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1927
1928
1929
1930 *** Version 0.9.4.1 (2005/08/18)
1931
1932 - callisto: fixed some problems with the calibration in case of
1933 inteleaved events. Therefor the final and some intermediate
1934 fits are skipped which would take place on partly filled #
1935 histograms and gave wrong results or failed completely.
1936
1937 - callisto: If the intermediate finalization of the histograms
1938 calculating the mean charge of the calibration signal fails
1939 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1940
1941 - ganymed: Fixed some bugs which caused problems in On-only mode.
1942 Still the false source plot doesn't give reasonable results.
1943
1944
1945
1946 *** Version 0.9.4 (2005/08/05)
1947
1948 - general: Fixed the ZA binning. It did not correctly fit the
1949 MC binning
1950
1951 - general: Added a class to correct for the missfocussing in
1952 April (MSrcPosCorrect)
1953
1954 - general: Random Forest energy estimator should now work properly
1955
1956 - general: MHCamera now displays the profiles in deg instead of mm
1957
1958 - general: MH::SetPalette offers a lot of new palettes
1959
1960 - general: MHillas - the case of CorrXY==0 is now handled properly
1961
1962 - general: implemented the possibility to change the line and
1963 marker style of a sky-grid drawn by MAstroCatalog
1964
1965 - general: Runs in sequences and datasets are now automatically
1966 ordered (it is assumed that the order of their filenames correctly
1967 represents the order of observations) to ensure correct reading
1968 of the subsystem data
1969
1970 - general: Runs cannot be added to a sequence twice anymore. Also
1971 Sequences cannot be added twice anymore to a dataset.
1972
1973 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1974 It gave wrong results by 1./2pi
1975
1976 - showplot: got a new option to start a root interpreter, too
1977
1978 - mars: now displays a rough estimate of Disp and the third moment
1979
1980 - mars: now displays the event time MTime if available
1981
1982 - mars: show muon parameters graphically
1983
1984 - mars: now the file to open can be given as commandline
1985 argument
1986
1987 - merpp: Added support for new arehucas version >= 200507190
1988 implementing values for three temperature sensors in the
1989 counting house (MCameraAUX) and the name of the HV settings file
1990 (MCameraHV).
1991
1992 - merrp: Also fixed some problems with wrong versions numbers stated
1993 by arehucas and implemented some fixed for old versions (<200407070)
1994
1995 - callisto: MCalibrationHiLoCam can now be printed from its context
1996 menu, eg in the TBrowser
1997
1998 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
1999 - 1.39 (MExtractTimeAndChargeSpline)
2000 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2001 This is important mainly for timing studies.
2002
2003 - callisto: Changed limits in MHCalibrationChargeCalc from
2004 - -100.125 to -98 (fgChargeHiGainFirst)
2005 - 1899.875 to 1902. (fgChargeHiGainLast)
2006 - -100.25 to -99 (fgChargeLoGainFirst)
2007 - 899.75 to 901. (fgChargeLoGainLast)
2008 Introduced new limits:
2009 - fgNumLoGainBlackoutLimit: 0.05
2010 - fgLoGainBlackoutLimit: 3.5
2011 - fgLoGainPickupLimit: 3.5
2012
2013 - callisto: The handling of automatic weights for the digital filter
2014 has been improved. There are now new calibration weights special
2015 for Monte Carlo calibrations.
2016
2017 - callisto: Updated Muon scale with latest results (1% difference
2018 for most data, 5% for Mar/Apr'05)
2019
2020 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2021 was saturated and the blackout-events in the low-gain exceed the
2022 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2023 This excludes those pixels which have a saturating high-gain
2024 channel, but the low-gain switch does not switch often enough
2025 to make the distribution reliable.
2026
2027 - callisto: fix a bug counting the number of saturated events. Up to now,
2028 the number of saturated slices was counted (which is one for a not too
2029 high number), but for some (pathological) pixels, many more slices
2030 saturated and produced wrong limits.
2031
2032 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2033 + MCalibrationRelTimeCam.CheckFitResults: Yes
2034 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2035 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2036 + MCalibrationRelTimeCam.CheckOscillations: Yes
2037
2038 - callisto: introduce max. number of events for intercalibration,
2039 the rest gets skipped. Default: 4096
2040 The calibration causes too many un-reliable pixels if more
2041 than about 5000 events are treated (@500 Hz) because of the
2042 mode hopping of the VCSels. However, in the past, some
2043 calibration runs have been taken (erroneously) with more
2044 than 5000 events, especially the intensity scans where
2045 a good precision is needed.
2046
2047 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2048 photo-electrons for the spline extractor by 1-2% (correctly).
2049
2050 - callisto: The intercalibration is now done using a full f-factor
2051 method instead of a simple update. This makes things slower but
2052 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2053 changes.
2054
2055 - callisto: MPedestalY3 now uses the same extraction range as the data
2056 as calculated by MPedestalY2
2057
2058 - callisto: A check of the fraction of allowed unsuitable (10%) and
2059 unreliable (30%) pixels has been addded when the conversion is
2060 calculated from interleaved events
2061
2062 - star: fixed a bug which caused MEffectiveOnTime containers not to
2063 be written. In the worst case they were skipped almost all, in the
2064 best case they were all ok. It depends on how often the new value
2065 was assigned just with an event which was skipped later by another
2066 task
2067
2068 - star: new histograms MHPointing and MHRate
2069
2070 - star: New tab (Currents) displaying the time evolution of the mean
2071 DC currents
2072
2073 - star: New tab (MeanRms) displaying the time volution of the mean
2074 Pedestal Rms
2075
2076 - star: Output now contains MReportStarguider
2077
2078 - star: Improved muon analysis. Due to the absense of a constant
2079 for the gaus fit for arc width and the fact that the arcwidth
2080 plot was a histogram instead of a profile the resulting psf
2081 became pedestal rms dependant
2082
2083 - ganymed: added new plot (MHPhi) for wobble mode as described in
2084 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2085
2086 - ganymed: corrects now (correctly?) for the misspointing in
2087 May/April 05
2088
2089 - ganymed: Two new default templates for ganymed.rc are avilable:
2090 ganymed_onoff.rc and ganymed_wobble.rc
2091
2092 - ganymed: The first version of MFMagicCuts has been released
2093
2094 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2095
2096 - ganymed, sponde: There are two new options to determin the number
2097 of bins for the signal region (NumBinsSignal) and the number of
2098 total bins (NumBinsTotal) in the MHThetaSq histogram
2099
2100 - ganymed: optimized palettes for MHDisp
2101
2102 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2103 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2104 sqrt(2) to large
2105
2106 - ganymed: The false source plot (MHDisp) is now based on Disp
2107 and a background model determined in the first loop is
2108 subtracted
2109
2110 - ganymed: MFMagicCuts are now available in the cvs. The correct
2111 solution for the disp ambiguity problem is now calculated using
2112 the third moment. The third moment cut therefor is skipped.
2113
2114 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2115 already determined by the third moment along the major axis and
2116 so its actual sign is aligned along the major axis of the shower.
2117
2118 - ganymed: If starguider data is available it is taken into account
2119 when calculating the source position. This is especially important
2120 for wobble data at high zenith angles and culmination data.
2121
2122 - ganymed: If available the starguider data is taken into account as
2123 good as it is possible without a starguider calibration. To switch
2124 it off add
2125 MPointingDevCalc.MaxAbsDev: -1
2126 to your ganymed.rc
2127
2128 - sponde: the zenith angle distribution is now weighted instead of
2129 choosen by default. This gurantees higher statistics in the highest
2130 and lowest energy bins. To switch this behaviour off use...
2131
2132 - sponde: now automatically displays the energy threshold
2133
2134
2135
2136 *** Version 0.9.3 (2005/06/03)
2137
2138 - general: MMcEvt now derived from MMcEvtBasic which should
2139 have no influence on compatibility with older camera files
2140
2141 - general: Implemented a new option to MReadReports which allows
2142 to force reading of the first event of some trees (eg. Drive-tree)
2143 before any other tree.
2144
2145 - general: Made a fix to MPointingPosCalc which assumes that the
2146 run-type is real-data if Process is called before ReInit, such
2147 that also the very first Drive-events in a run are treated
2148 correctly.
2149
2150 - shoplot now displays the filename in the title bar of the window
2151
2152 - merpp: new options: --auto-time-start --auto-time-stop which
2153 allow to cut updating with slow-control at the start- or
2154 (previousle --auto-time only allowed: and) stop-time of
2155 the run stored in the runheader.
2156
2157 - callisto: changed default of fgFallTimeHiGain in
2158 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2159 already set as default in callisto_Dec04Jan05.rc
2160
2161 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2162 now changes the filename for new weights automatically for
2163 cosmics, MC and for different calibration colors.
2164
2165 - callisto: a problem with the order of some code cause the
2166 name of the weights file in MPedestalY2 to be ignored.
2167 Wrongly the calibration_UV weights were used instead
2168 of the cosmics weights set in callisto.rc.
2169
2170 - callisto: should allow ct1 pulser data when the color is
2171 explicitly set also for pretty new runs
2172
2173 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2174 to introduce an additional scale factor (should be around 1)
2175 to adapt for slight deviations in different extractors from
2176 the MC calibration. For MC calibrations the scale factor
2177 is fixed to 1
2178
2179 - callisto: MFCosmics should handle very high signals a bit
2180 more accurate now
2181
2182 - callisto: when calculating the mean pedestal rms for different
2183 pixel sizes or sectors also kUnsuitableEvt is now taken into
2184 account - not only kUnsuitableRun
2185
2186 - callisto: '-raw' option is now the default
2187
2188 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2189 This has the advantage that mean values in the calibration (eg
2190 arrival times) are calculated more accuratly.
2191
2192 - callisto: In the resource file callisto_Dec04Jan05.rc
2193 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2194
2195 - callisto: new Hi-/Lo-Gain intercalibration constants
2196 hilocalib_sp1.root and hilocalib_sp1_mc.root
2197
2198 - callisto: changed default for MJPedestalY2.MaxEvents
2199 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2200
2201 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2202 has changed from 9.0 to 6.0. This is necessary to exclude two very
2203 ringing pixels in September which - when kept - destroy the image
2204 cleaning around them (Markus G.)
2205
2206 - callisto: (!) The Muon analysis of all data taken so far has
2207 suggested that different extractors give slightly different
2208 absolute results after calibration, due to there different
2209 handling of the calibration- and cosmics pulse shape. Although
2210 the over all calibration seems to be a bit to pesimistic (or
2211 the MC seems to be a little bit - 3-5% - too much attenuated).
2212 There for correction factors have been introduced which correct
2213 the calibration constants by
2214 0.956937799 for Digital Filter (callisto.rc)
2215 and
2216 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2217 calibration. The main advantage is, that both data types can
2218 be easily analysed together and compared to the same MC sample.
2219 The factors are choosen such, that the reference is now a
2220 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2221
2222 - star: fixed a bug which caused the first bin of the histograms
2223 vs time to disapear in PostProcess. This gave wrong results
2224 on the screen. The output and all following programs not
2225 directly accessing the histograms haven't been affected
2226
2227 - star, ganymed: Made sure that always the first Drive-tree event
2228 is read and Processed before the first data event was read.
2229
2230 - ganymed: implemented the possibility to replace the standard
2231 false source plot with a different one. For example: If
2232 you want to use a Disp based FS plot use the resource:
2233 NameHistFS: MHDisp
2234 For details about the requirements of these plots look
2235 at the corresponding classes
2236
2237 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2238 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2239 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2240 case MAlphaFitter is setup correctly. For On-Only optimization
2241 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2242 RunOn() instead of Run(). For energy estimation MJOptimize
2243 has been replaced by MJOptimizeEnergy
2244
2245 - sponde: The input MC spectrum can now be weighted to fake a
2246 different spectrum. This is done via MMcSpectrumWeight. For
2247 more details see the class description and sponde.rc
2248
2249 - sponde: The paremeter comparsion plots are not scaled by
2250 their entries anymore. Instead the MC plot is scaled by using
2251 the result spectrum of the analysis. If the input MC spectrum
2252 and the result spectrum has different slopes the absolut
2253 normalization is normally wrong.
2254
2255
2256
2257 *** Version 0.9.2 (2005/05/20)
2258
2259 - general: Changed the default paths for calibrated data and image
2260 files. (The implemented access to these files doesn't yet exist)
2261
2262 - general: support for MRunIter has been removed from the job classes
2263 (use the setter functions of MSeqeunce instead)
2264
2265 - general: ProcessFile has been renamed to Process in all job classes,
2266 because ProcessFile is missleading
2267
2268 - general: The storage of the palette in MHCamera is now possible
2269
2270 - general: new bits describing unsuitable and unreliable pixels have
2271 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2272 kDeadPedestalRms, kFluctuatingArrivalTimes
2273
2274 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2275 versions newer than V200404070
2276
2277 - general: support for cc file versions newer than V200504130. Added
2278 support for active loads (MCameraActiveLoad) and central pixel
2279 (MCameraCentralPixel)
2280
2281 - general: added new histograms for image parameters versus size
2282 (MHVsSize)
2283
2284 - general: The eventloop now automatically calls PrintStatistics
2285
2286 - Status Display: Improved support for printing:
2287 + A default can now be set in .rootrc (for more details see
2288 MStatusDisplay::PrintPS)
2289 + A print dialog is opened so that printer and command line
2290 can be canged
2291
2292 - showlog: improved such that it handles different verbosity levels
2293 more accurate now. This mean you can suppress output when
2294 using showlog.
2295
2296 - showplot: improved
2297 + The new graphics formats have been implemented
2298 (pdf, svg, png, jpg and xpm)
2299 + Implemented an interface for printing. Because you can change
2300 the printing command from the command line you can use all
2301 the nice postscript tool. To print a booklet for example call:
2302 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2303 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2304 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2305
2306 - callisto: fixed a bug in the recognition of the calibration bit
2307 pattern. Concerns only intensity calibration. (The strength of the
2308 intensity has been updated in some cases)
2309
2310 - callisto: add a filter against PIN Diode events when running over
2311 calibration runs since some of the recent calibration runs have
2312 been taken with Pin Diode.
2313
2314 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2315 39943, 44833 in the calibration (MCalibColorSet)
2316
2317 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2318 been set to 1e-18 in callisto_Dec04_Jan05.rc
2319
2320 - callisto: in callisto_Dec04Jan05.rc: set value for
2321 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2322 statistics for the calculation of the mean pulse time
2323 of the cosmisc
2324
2325 - callisto: the charge limit in the calibration has been raised
2326 from 2.5 to 4.5
2327
2328 - callisto: new setup read from callisto.rc
2329 + MCalibCalcFromPast.fNumEventsDump
2330 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2331 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2332
2333 - callisto: MExtractTimeAndChargeSpline extractor:
2334 + The integration ranges were shifted by 0.2 FADC slices to the right.
2335 + unreliable handling of floating point values caused different
2336 results on different platform or with different compiler options:
2337 The new algorithm is numerically exact and more accurate because
2338 it doesn't calculate the integration position by multiple times
2339 adding the step-size (which results in numerical uncertanties
2340 exspecially if multiplied with large numbers)
2341 + A lot of fixes have been introduced which effects integrating the
2342 spline at the edges of the valid range. In this case any memory
2343 was randomly accessed. This behaviour can be tested replacing
2344 all MArrayF by TArrayF which perform a range check (but of course
2345 they are a lot slower)
2346 ! No result obtained with the Spline before can be trusted! Due to
2347 random memory access it might by completely random!
2348
2349 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2350 + extraction range in the high gain to 4.
2351 + weights file to cosmics_weights46.dat
2352
2353 - callisto:
2354 + introduce the check for fluctuating arrival times.
2355 + set charge limit to from 2.5 to 4.5
2356 + introduce asymmetric exclusion due to "deviating number of phes":
2357 Default: -9.0 +4.5
2358 + make deviating number of phes unsuitable (see David's findings).
2359
2360 - callisto: fixed the display of unsuitable pixels. The old change
2361 to a real profile in MHCamera broke it.
2362
2363 - callisto: The cosmics filter is used in MJCalibration now
2364 independant of the pulser color (formaly it was used only for
2365 CT1-pulser data). The threshold of number of max empty pixels
2366 has been raised from 2% to 5% in MJCalibration. The maximum
2367 fraction of rejected event is 50% otherwise the calibration has
2368 failed. The filter now ignores unsuitable pixels.
2369 Setup the filter from callisto.rc using "ContCosmics"
2370 (see MFCosmics::ReadEnv)
2371
2372 - callisto: changed default for fgOffsetFromLogain back
2373 from -2.8 to -1.8 in digital filter.
2374
2375 - callisto: for the common extractors
2376 + MExtractFixedWindow
2377 * MExtractTimeAndChargeSlidingWindow
2378 * MExtractTimeAndChargeSpline
2379 * MExtractTimeAndChargeDigitalFilter
2380 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2381 and fResolutionPerPheLoGain
2382
2383 - callisto: Updated the hi-/lo-gain intercalibration constants
2384 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2385 hilocalib_df6.root
2386
2387 - callisto: The default lo-gain extraction window for the
2388 MExtractTimeAndChargeSlidingWindow extractor has been increased
2389 from 6 to 8 to take the stretch of the pusle into account
2390
2391 - callisto (!!!): fixed an important bug in the setting of the
2392 incoming pedestal pointer to the signal extractor extracting
2393 pedestals. This bug caused the pedestals not to be subtracted
2394 correctly in the calibration afterwards. The effect was about 10%
2395 too high conversion factors for the digital filter and the spline
2396 and more than 40% for the sliding window.
2397 The bug existed since end of February! (Markus G.)
2398
2399 - star: added muon support to star. A new tab "MHMuonPar" is
2400 displayed. The lower right plot is an estimate of the point spread
2401 function. A reference value is displayed. To get the real PSF
2402 you must compare with MC. The setup for the muon analysis
2403 is done in star.rc. More informations can be found in
2404 MHSingleMuon and MHCalibParCalc
2405
2406 - star: The weather data is now displayed in star
2407
2408 - star: MEventRateCalc handles the calculation of the event rate more
2409 accurate now in case of the start of a new run inside a sequence
2410
2411 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2412 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2413 changed only minimally
2414
2415 - ganymed: (MJCut and MJOptimize) now displayes the number of
2416 excess events versus size. The energy estimation is done in
2417 MJSpectrum (sponde)
2418
2419 - ganymed: got support for using other variables than Alpha, eg. Theta.
2420 Therefor you need a class deriving from MHAlpha which supports
2421 this variable (one is already existing: MHTheta, which is now the
2422 default in ganymed). It is setup through ganymed.rc
2423
2424 - added a full featured spectrum program (sponde) which reads
2425 ganymed output and monte carlos and compiles a spectrum
2426
2427
2428
2429 *** Version 0.9.1 (2005/04/14)
2430
2431 - Fix bug on the arrival time reconstruction when using Digital
2432 Filter (in some marginal cases (10%) times were reconstructed shifted
2433 by 0.2 slices)
2434
2435 - all executables now return 2 where in previous versions -1 has
2436 been returned (gave problems with shell-scripts)
2437
2438 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2439 also done with a intercalibration input file
2440
2441 - a bug in the time fine adjustment of the digital filter has been fixed
2442
2443 - a lot of small fixes to calling TPad::Divide with a margin==0
2444
2445 - MStatusDisplay now shows the memory usage
2446
2447 - added a memory leak statistic after the eventloop
2448
2449 - MHadronness replaced by MParameterD
2450
2451 - MEnergyEst replaced by MParameterD
2452
2453 - wobble mode can now be switched on from the data-set
2454
2455 - switched on bad pixel detection for a pedestal level
2456 which is more than 5 times the variance
2457
2458 - Fixed default paths to be correct for the new data center
2459
2460 - Fixed handling of drive data. The pointing position in now
2461 copied to MPointingPos inside star for real and MC events
2462
2463 - made sure, that the sequences in a dataset are sorted by
2464 their number to ensure the correct synchronization
2465
2466 - added all resource files necessary to handle spline extraction
2467 of signal for the late 2004 and the early 2005 data
2468
2469 - update the reference lines for the december data
2470
2471 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2472 This is important for the Dec. and Jan. data where the calibration
2473 pulse position changes much.
2474
2475 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2476 filter. This corrects only an defective extraction of the MC at
2477 low-gain signals lower than 90 phes.
2478
2479 - fixed some slowdown in calibrating data with interleaved events from
2480 Jan and Dec. As a workaround made the pretty palette the default.
2481 The inverse Deep Blue Sea has a bug which slows down long calibration
2482 runs a lot.
2483
2484 - implemented new values from new starguider report as defined
2485 in TDAS00-07 V7.1 (eg SkyBrighness)
2486
2487 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2488 in starguider report (If you merpp the same reports with this version
2489 you'll get the correct units (arcmin) but a different result
2490 than with old versions (wrong units))
2491
2492 - Now the status display can also write PNG, JPEG and XPM (other file
2493 formats are still unsupported by root)
2494
2495 - added a lot of scripts and macros in directory datacenter used
2496 for automatic processing
2497
2498
2499
2500 *** Version 0.9 (2005/03/23)
2501
2502 - Calibration is now done autmatically into photo-electrons like
2503 decided by the Collaboration Board
2504
2505 - Reference lines in the display can be read from resource file
2506
2507 - Interlaced calibration events can be handled by callisto
2508
2509 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2510 and applied in callisto.
2511
2512 - class MJCalibTest can be called by callisto
2513
2514 - callisto can now run with three data types: rawdata, rootdata, MC
2515
2516 - added two classes mreport/MReportStarguider.cc and
2517 mreport/MReportStarguider.h for implementing starguider-data
2518
2519 - the output of merpp-update now contains starguider information:
2520 MReportStarguider and MTimeStarguider
2521
2522 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2523 values were lower than they should. This was more visible for high
2524 energy (Size) events.
2525
2526 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2527
2528 - added a new loop to callisto to support the correct extraction of
2529 the pedestal and pedestal rms through the signal extractor
2530
2531 - added class to perform fourier tranformation of a hexagonal structure
2532 (MHexagonalFT)
2533
2534 - added class to perform fourier tranformation of a hexagonal structure
2535 in a tasklist (MHexagonalFTCalc) example: hft.C
2536
2537 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2538 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2539 small pixels, example: extendcam.C
2540
2541 - added possibility to write data to memory (TTree) using MWriteRootFile
2542
2543 - added possibility to read a TTree stored only in memory by MReadTree
2544
2545 - new classes to deal with the interleaved calibration events:
2546 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2547
2548 - implemented filters to callisto to skip calibration events
2549
2550 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2551 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2552 the slices by statistics
2553 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2554 signal extractor without randomization
2555 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2556 with the signal extractor with randomization (extraction window is
2557 randomly fixed)
2558 The three kind of pedestal is not yet implemented (for speed reasons) as
2559 long as nobody really needs it:
2560 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2561 extracted with the signal extractor with randomization
2562
2563 - callisto now finds the pulse position in the data automatically
2564
2565 - implemented data reduction in calibrated data by reducing the precision
2566 of the stored floating point values (pedestal, rms and signal) to
2567 roughly 0.5%
2568
2569 - fixed showplot to make file format conversion (eg. converting a
2570 status display stored in a root file into a postscript file) in
2571 batch mode possible:
2572 showplot -b --save-as-ps[=outfile.ps] infile.root
2573
2574 - Allow class names as part of filter rules, eg
2575 (MFSupercuts) && (MHillas.fSize>100)
2576
2577 - fixed a lot of stuff to allow all programs to process MonteCarlo
2578 camera files.
2579
2580 - enhanced possibility to debug reading of resource file
2581
2582 - MDataChain should handle priorities of operator more
2583 accurate now
2584
2585 - completely revised the container in which the signal is stored
2586 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2587 * the new implementation is faster and
2588 * needs less storage space
2589
2590 - FIRST version which can process Monte Carlos through the
2591 whole chain of programs (callisto, star, etc)
2592
2593 - implemented new image parameters for the border length of
2594 the shower image (MNewImagePar2)
2595
2596 - implemented wobble-mode in ganymed
2597
2598 - new class (MJOptimize) taking care of all optimization processes
2599
2600
2601
2602 *** Version 0.8.6 (2004/10/05)
2603
2604 - New combined signal and time extractor
2605 MExtractTimeAndChargeDigitalFilter
2606
2607 - The Report for the trigger section in the CC run summary has been
2608 updated, and now the IPRs (Individual Pixel Rates) are available.
2609
2610 - new macros for database interaction: filldotrun.C, filldotrbk.C
2611
2612 - added new program which can convert colored output which was redirected
2613 into a file back into colored text (for example to display it with
2614 more): showlog
2615
2616 - added new program to display an MStatusArray of plots (stored with
2617 MStatusDisplay) from a file: showplot
2618
2619 - Added support for Sequences (MSequence). Sequences are blocks of run
2620 files containing the same calibration and belonging to the same
2621 source
2622
2623 - Added a new task (MTaskEnv) which can be used in setup files to switch
2624 between different tasks (for example to choose a signal extractor)
2625
2626 - Implemented automatic file splitting in MWriteRootFile
2627
2628 - After image cleaning an island index is assigned to all used pixels.
2629 The index corresponds to the order of the islands in size.
2630
2631 - added a cleaning which takes signal height _and_ arrival time into
2632 account: probability cleaning (for more details see MImgCleanStd)
2633
2634 - added a cleaning which takes takes the absolute number of photons
2635 times the area ratio as cleaning level
2636 (for more details see MImgCleanStd)
2637
2638 - Changed calculation of image parameters such, that it can be done
2639 for all used pixels or the pixels with a defined island index only
2640
2641 - implemented new image parameters displaying the number of islands,
2642 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2643
2644 - event display in executable changed to support also calibrated files
2645 (done with MJCalibrateSignal)
2646
2647 - added program doing the calibration and the signal extraction
2648 and signal calibration: callisto Most part of the setup is done
2649 by a resource file: callisto.rc
2650
2651 - implemented support for pixels with negative IDs (Raw file format
2652 version 4)
2653
2654 - implemented an new option in merpp (--auto-time) to get the time
2655 range for cc and/or caco data from the run header of the raw data
2656
2657 - New star-program (star and MJStar). Taking calibrated data from
2658 callisto/MJCalibrateSignal as input. The setup is done through
2659 a resource file: star.rc
2660
2661 - Added possibility to setup the eventloop in the mars-executable
2662 Camera Display by a resource file: mars.rc
2663
2664 - The the mars-executable Camera Display can now also read
2665 calibrated data files written by callisto/MJCalibrateSignal
2666
2667 - Added a new class which can calculate the source position in
2668 the camera from a pointing model known to be correct and
2669 the pointing model used for observations (MSrcPosFromModel)
2670
2671 - added a new version of the class calculating the effective on-time
2672 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2673 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2674 MHTimeDiffTheta.
2675
2676 - added the possibility to count how often a signal is above (or
2677 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2678 can replace MHTriggerLvl0)
2679
2680 - added ore convinient ways to set the axis-titles of your histograms
2681 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2682 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2683
2684
2685
2686 *** Version 0.8.5 (2004/08/06)
2687
2688 - new Signal Extractors: MExtractFixedWindowSpline
2689 and MExtractAmplitudeSpline
2690
2691 - implementes interleave in merpp to be able to merpp parts of a file
2692
2693 - implemented force-functionality to merpp
2694
2695 - star display to display star catalogs (MAstroCatalog)
2696
2697 - star display to 'mirror' stars to the camera (MAstroCamera)
2698
2699 - implemented a new cleaning option which allows cleaning scaled with
2700 the real ratio of the rms depending on the pixel size, not only the
2701 square root of the pixelsize (MImgCleanStd, MCameraData)
2702
2703 - removed obsolete MBlind* classes
2704
2705 - Signal extractor taking the AB flag into account implemented (this makes
2706 an odd number of slices for signal extraction possible
2707 (MExtractSignalABcorr)
2708
2709 - implemented a class extracting the pedestal from the raw-data (events)
2710 itself using empty lo-gain (MpedCalcFromLoGain)
2711
2712 - Added mean values to MPedPhotCam
2713
2714 - Added Makefile for Darwin (this OS is NOT officially supported!)
2715
2716
2717
2718 *** Version 0.8.4 (2004/04/19)
2719
2720 - new fast arrival time extractor using cubic splines:
2721 MExtractTimeFastSpline
2722
2723 - implementes multi-argument support in MDataChain
2724 ("pow(a, b)")
2725
2726 - implemented double reference support in MDataChain
2727 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2728
2729 - added support in MF for expressiond like
2730 "MHillas.fWidth<2*<MHillas.fLength"
2731
2732 - MDataChain is now able to support variables like [0], [1], ...
2733 which can be used in fit functions as parameters. The interface
2734 is implemented through the new virtual function
2735 MParContainer::SetVariables
2736
2737 - added new class MArrivalTimeCam/MArrivalTimePix:
2738 Storage containers to hold the ArrivalTime of the camera/pixel
2739
2740 - added new classes for the calibration of relative arrival times:
2741 MCalibrationRelTimePix and MCalibrationRelTimeCam
2742
2743 - added new classes to extract the signal of the blind pixel and the
2744 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2745
2746 - added new classes for the bad-pixels treatment (MBadPixels*)
2747 which are more powerfull than the old ones (MBlindPixel*)
2748 and will replace them.
2749
2750 - added filter against cosmics: MFCosmics
2751
2752 - added new class MArrivalTimeCalc2:
2753 Calculates the arrival time as the signal weighted mean of the time
2754 slices in the maximum window
2755
2756 - added a new macro call pointspreadfucntion.C that fits with a 2D
2757 gaussian the DC spot for an star. It gives you the RMS of
2758 the PSF and the center of the star, very useful for misspointing
2759 studies.
2760
2761 - added support for multi-telescope camera files. Added classes
2762 MStereoCalc and MStereoPar, classes to calculate and store shower
2763 parameters calculated from the data of two telescopes, for the MC
2764 studies regarding the MAGIC clone.
2765
2766 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2767 MC data calibrated in photons instead of ADC counts.
2768
2769 - added three macros to show the calibration and analysis chain of
2770 MC data. The macro starmc.C does both calibration and analysis, producing
2771 an output containing Hillas parameters for each event. The macro
2772 mccalibrate.C does just the calibration and writes out a file containing
2773 pixel information in photons instead of FADC data. The macro starmc2.C
2774 reads in such a file and produces an output with Hillas parameters.
2775
2776 - added MPedPhotCalc to compute pedestals in units of photons, see
2777 macro pedphotcalc.C
2778
2779 - added all class to perform the calibration, see macro calibration.C
2780
2781 - added class MFFT to perform Fast Fourier Transforms
2782
2783 - added class MSimulatedAnnealing to perform simulated annealing
2784 minimizations
2785
2786 - added new macro bootcampstandardanalysis.C which holds the skeleton
2787 of the analysis chain discussed in the december bootcamp.
2788
2789 - added support for DAQ raw data file format V2
2790
2791 - implemented an arbitrary time stamp for the events from raw-data
2792 files with file version<3. It is calculated from the run number,
2793 the date of start and the FADC clock tick from the first module
2794
2795 - implemented the correct decoding of the event time-stamp
2796 coming from the DAQ for raw-data files with file-version>2
2797
2798 - added a new classes storing the pedestals in units of photons:
2799 MPedPhotPix, MPedPhotCam
2800
2801 - added support for DC current files from the camera control
2802
2803 - added support for start- and stop-time when merpping report files
2804
2805 - added MReportCC storing the weather data from the CC-REPORT
2806
2807 - added class to fill trainings and test matrices (MTFillMatrix)
2808
2809 - added a filter performing a software trigger (MFSoftwareTrigger)
2810
2811 - Added classes to perform parts of the standard analysis (Jobs):
2812 + MJPedestals
2813 + MJCalibration
2814 + MJExtractSignal
2815 Note: All of them are preliminary!
2816
2817 - Added Iterator to iterate over files giving only the run-number
2818
2819 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2820 the evolution of a sector vs time
2821
2822
2823
2824 *** Version 0.8.3 (2003/12/05)
2825
2826 - adapted Random Forest classes to allow the use with MC
2827 multi-telescope files which can be produced with the coming
2828 camera version 0.7.
2829
2830 - added classes to read and interprete central control report files
2831 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2832
2833 - enhanced merpp (the executable) to support .raw and .rep files.
2834
2835 - added classes for light calibration (MCalibration* and
2836 MHCalibration*) by Markus Gaug. Further work has to be and will
2837 be done soon.
2838
2839 - Added a preliminary 'synchronizer' (MReadReports) which will
2840 replace MReadMarsFile as soon as it is finished.
2841
2842 - Added a tutorial macro demonstrating how report files are merpped
2843 and how they can be read from the root file in the correct order
2844 of time (readrep.C)
2845
2846 - Added a generalized histogram (similar to MH3) called MVsTime
2847 which allows to plot variables (or rules - MDataChain - of
2848 variables) vs time. For an example have a look at tempvstime.C.
2849
2850 - Changed the name of the event trees:
2851 + Events --> Events
2852 + PedEvents --> Pedestals
2853 + CalEvents --> Calibration
2854
2855 - changed name of MTime in the event trees from MRawEvtTime to MTime
2856
2857 - added displaying the sector indices to the mars event display
2858
2859 - Magic Online Analysis (MOnA) implemented in a first version
2860 (see mona.cc, MOnlineDump and MOnlineDisplay)
2861
2862 - added classes to calculate event rate
2863 (preliminary: MEventRateCalc, MEventRate)
2864
2865 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2866
2867 - added classes dealing with the telescope pointing position (MPointing*)
2868
2869 - implemented the 'final' Mars time stamp based on some experiences with
2870 the new 'Synchonizer'
2871
2872
2873
2874 *** Version 0.8.2 (2003/11/10)
2875
2876 - accelerated standard analysis by a factor of 6-8 ...
2877 + doing precalculations in MGeomCam for the pixel area ratio
2878 + creating a look up table for the single pixels in MCerPhotEvt
2879
2880 - added task to calculates weights in case you want to 'change'
2881 the energy spectrum of a monte carlo file
2882 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2883
2884 - added a new executable star which implements the
2885 star.C macro as precompiled executable. Currently a flexible
2886 setup is not possible, but a 'input card' setup will follow.
2887
2888 - Starting to implement Multi-Telescope-Support based on the
2889 upcomming camera version 0.7. The base for a general support
2890 is implemented and the star-functionality is proven to work.
2891
2892 - Replaced Event-Display in and Camera-Display in the Mars GUI
2893 executable by a more convinient display base on MStatusDisplay.
2894
2895 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2896
2897
2898
2899 *** Version 0.8.1 (2003/10/20)
2900
2901 - added signal subtraction for pure on data by means of fitting
2902 the background in the off region or by performing a combined
2903 signal/background fit. Provides necessary histograms for
2904 obtaining energy spectra and a light curve.
2905
2906 - added classes to perform and study the selection of the
2907 2nd Level Trigger on MC data (example in triglvl2.C macro)
2908
2909 - added pedestal calculation
2910
2911 - implemented "democratic cleaning" (tail cut value proportional
2912 to pixel area) according to Wolfgang's suggestion.
2913
2914 - added Sigmabar treatment (calculation and basic histogramming)
2915
2916 - added basic routines to apply padding
2917
2918 - added first implementation of MARS-based source visibility plotter
2919 (needs to be linked against slalib, preliminary version)
2920
2921 - enhanced functionality of data chains: random numbers, conversion
2922 functions and access to MHMatrix objects
2923
2924 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2925 numbers under certain circumstances (runs with 0 events included)
2926
2927 - fixed a bug in the general filter MF (didn't work on some systems
2928 at all)
2929
2930 - fixed a bug in chaining files, which caused the analysis to crash or
2931 ignore files
2932
2933 - implemented more geometry classes describing the parameters used
2934 to simulate the PMT camera
2935
2936 - added new Monte Carlo classes containing the setup of the different
2937 programs in the MC chain.
2938
2939 - added a (preliminary) general task to evaluate chi-square of a given
2940 parameter in an eventloop.
2941
2942 - first implementation of a container describing the observatory
2943 location (Long, Lat, etc)
2944
2945 - added Random Forest - method for g/h-separation
2946
2947 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2948 (this means, that it is compiling, but not yet fully tested)
2949
2950 - added a new status display which can show the present status
2951 of histograms while an eventloop is running (MStatusDisplay,
2952 an example can be found at status.C)
2953
2954 - reorganized directories:
2955 classes describing the image --> mimage
2956 classes containing Monte Carlo Histograms --> mhistmc
2957 classes for Random Forest method --> mranforest
2958
2959 - added (event-)weights to fill histograms
2960
2961 - colors in logging output to screen
2962
2963 - changes to the Image Parameter declaration:
2964 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2965 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2966 + MHillasExt now derives from MParContainer instead of MHillas
2967 --> Files written with the old definition are more or less unreadable
2968
2969 - reading of reflector files
2970
2971 - display data from reflector files in the camera
2972
2973 - implemented currents (and display them in the camera)
2974
2975 - logarithmic scale in camera
2976
2977 - added class to iterate through directory contents (MDirIter)
2978
2979
2980
2981 *** Version 0.8 (2002/11/18)
2982
2983 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2984
2985 - corrected 48(!) wrong entries in the Next Neighbor table of the
2986 Magic Camera (all in the inner part of the outer ring, mostly
2987 missing a single NN)
2988
2989 - Fixed a bug in the table describing the Next Neighbours of the
2990 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2991 have any neighbour)
2992
2993 - changed trigrate.C: now it calculates the pure NSB triggers from
2994 a camera file (generated with no showers), so there is no need
2995 to introduce them by hand in the BgR array (for more details
2996 please ask Abelardo)
2997
2998 - added MHHadronness (and MHadronness) as a general facility to evaluate
2999 the quality of a gamma-hadron seperation method
3000
3001 - changed MWriteAsciiFile to accept rules (MDataChain)
3002
3003 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3004 must be replaced by calles to MWriteAsciiFile::AddColumn and
3005 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3006 changed.
3007
3008 - Implemented generalized event-matrices (one row per event)
3009 (MHMatrix)
3010
3011 - implemented the one dimensional composite probabilities
3012 (MHCompProb, MCompProbCalc, comprob.C)
3013
3014 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3015 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3016
3017 - Added a camera display displaying the pixel numbers to the
3018 event display gui.
3019
3020 - Added Monte Carlo Informations to event display gui
3021
3022 - Changed the camera display to display the pixel numbering
3023
3024 - Added three buttons to the camera display to change the palette
3025
3026 - Added the number of used and core pixels after image cleaning
3027 to MHillas
3028
3029 - Changed the algorithm used in MHillas according to TDAS 02-03
3030
3031 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3032
3033 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3034
3035 - Added fCosDeltaAlpha to MHillasSrc
3036
3037 - The numbers of photons used to calculate fConc and fConc1 in
3038 MHillasExt are now scaled with the pixel size, so that one get
3039 a four times smaller value for the bigger pixels in the outer ring.
3040
3041 - added new task to smooth the camera contents (MCameraSmooth)
3042
3043 - added possibility to use interpolated pixel values for blind pixels
3044 instead of removing it completely from the analysis
3045
3046 - Implemented the possibility to save the whole eventloop with
3047 its setup to a file. This information can be read and from
3048 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3049 and MEvtLoop::MakeMacro. If you find something not working, please
3050 report - this stuff is still in a beta phase.
3051
3052 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3053 file having crab starfield, but also for all following files - fixed
3054
3055 - MTaskList::PrintStatistics can now be instructud to print also the
3056 title, too: use PrintStatistics(0, kTRUE)
3057
3058 - Changed the image cleaning so that pixels with to many 'used'
3059 neighbors are left used (to get rid of 'holes' in events)
3060
3061 - Introduced more output to the camera displays
3062
3063 - Added an array of histograms (eg one hist per run), MHArray
3064
3065 - Added a _preliminary_ version of the reader for CT1 PreProc files
3066 (MCT1ReadPreProc)
3067
3068 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3069 (thanks to Raquel)
3070
3071 - added the first energy estimator (MEnergyEstParam, estimate.C,
3072 estfit.C) using a parametrization
3073
3074 - Added some new Monte Carlo paremeter containers used to store
3075 setup information from the MC chain (MMcConfigRunHeader,
3076 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3077
3078
3079
3080 *** Version 0.7 (2002/04/30)
3081
3082 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3083 the pedestal mean value was saved incorrectly. For files from
3084 this versions we substract 0.5 from the pedestal mean.
3085 WARNING: This may effect your results, so don't wonder...
3086
3087 - First implementation of an algorithm using only triggered events
3088 for the collection area calculation
3089
3090 - Ascii Output can now also be used for parameter containers which
3091 doesn't overload MParCointainer::AsciiWrite
3092
3093 - The Ascii Output is now also capable of writing single data members
3094 of one container
3095
3096 - You are now able to change the order of the values written to the
3097 ascii file
3098
3099 - You can now specify a conversion factor for each data member written
3100 to an ascii file. This may be usefull to change the units of the
3101 data member (eg. degrees instead of millimeters in case of the
3102 hillas parameters)
3103
3104 - Replaced old MHillas by a new structure which allows you to extend
3105 the parameters stored in MHillas very easily:
3106 see MHillas and MHillasExt
3107
3108 - Added classes to handle source dependancy of image parameters:
3109 see MHillasSrc
3110
3111 - Added container (MBinning) to have a standard input for the binning
3112 in different histograms (eg. the Energy bins should be the same in
3113 all histograms)
3114
3115 - Changed Hillas histograms from mm to deg
3116
3117 - Added the flexible binning to the hillas histograms
3118
3119 - Added a filter for the alpha parameter (MFAlpha)
3120
3121 - It is now possible to write single data members of a class object to
3122 an output stream instead of the whole container only
3123
3124 - Added a generalized filter for a data member:
3125 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3126
3127 - Added a generalized Filter parser for more difficult filter rules
3128 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3129
3130 - Added new Monte Carlo histograms:
3131 MHMcEnergyImpact and MHMcEfficiency
3132
3133 - Added many new histograms needed for the flux calculation.
3134
3135 - Added a generalized histograms which can fill and show up to three
3136 data members in either a one-, two- or three-dimensional histogram, eg:
3137 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3138
3139 - Added:
3140 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3141 * calculation of <Theta> as a function of time (MHThetabarTime)
3142 they are needed in the flux calculation in
3143 order to select for a given bin in Theta (or time) the appropriate
3144 effective collection area, which is assumed to be given as a function
3145 of Theta and the true energy
3146
3147 - Added calculation of the migration matrix in the energy
3148 (MHMcEnergyMigration):
3149 the migration matrix describes the migration from the true (E_true)
3150 to the estimated energy (E_est); it is needed to determine the
3151 distribution of E_true from the measured distribution of E_est
3152 by unfolding
3153
3154 - changed the color palette in the camera display to DeapSea.
3155
3156
3157
3158 *** Version 0.6 (2002/01/15)
3159
3160 - Introduce the option of disable pixels (MBlindPixels and
3161 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3162 able to deal with Star Field NSB.
3163
3164 - Fixed a bug in the pedestals substraction
3165
3166 - Introduced verbosity levels
3167
3168 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3169
3170 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3171 work correctly (thanks to Abelardo)
3172
3173 - Introduced correct treatment of the diffuse Night Sky Background
3174 and NSB (MMcPedestalNSB)
3175
3176 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3177
3178 - Introduced MMcRunHeaders which contains monte carlo run informations
3179
3180 - Added a 'Print'-Task (MPrint) which calls the Print function
3181 of a parameter container for each event
3182
3183 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3184
3185 - changes to be more efficient with root 3.02/06
3186
3187 - root 3.02/06 fixes:
3188 + the memory leak when reading MRawEvtData
3189 + loosing more time than necessary to update the progress bar
3190
3191 - MWriteAsciiFile is now capable of writing more than one container
3192 in a line. For example: To be able to write Monte Carlo and
3193 Hillas values (energy and alpha) in one line.
3194
3195
3196
3197 *** Version 0.5 (2001/11/06)
3198
3199 - Added new GUI functionality (Analysis)
3200
3201 - Added a camera display to be able to display events in the camera
3202 together with the calculated hillas ellipse
3203
3204 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3205 object at any state of the analysis, so that the output are several
3206 states
3207
3208 - Fixed a bug in the collection area error calculation
3209 (Thanks to Ciro and Abelardo)
3210
3211 - Fixed a bug which causes merpp to crash in some environments
3212
3213 - Implemented auto enabling scheme for Branches to speed up reading
3214 a lot (see MReadTree and MTask)
3215
3216 - Fixed a bug in the Histogram classes which caused histograms to
3217 be written to a file by MWriteRootFile without request
3218
3219 - changed the object I/O from the old stylish root I/O to the new
3220 'auto evolution scheme' This was done only for classes which are not
3221 yet used in Monte Carlo files, so that these files are still readable.
3222
3223 - Added support for a progress bar in MEvtLoop and MReadTree
3224 (see the Analysis Window in Mars for an example)
3225
3226 - Fixed a bug in the package creation which disturbed the conversion
3227 between a mars version unpacked from a tar file and the repository.
3228
3229 - Changed the code to writer merpped (converted into root format)
3230 raw files, to get faster (around 10%)
3231
3232
3233
3234 *** Version 0.4 (2001/09/20)
3235
3236 - This release is made to compile on a root version >= 3.00
3237
3238 - Fixed a bug which causes MReadTree to read the first file only
3239
3240 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3241
3242 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3243
3244 - Added a task to write several container to a root file (MWriteRootFile)
3245
3246 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3247
3248 - Added calculation of the collection area (MMcCollectionAreaCalc)
3249
3250 - fixed some bugs in the Hillas calculation
3251
3252 - added filters to be able to control the task execution dependent on
3253 a parameter (for example: the number of level 1 triggers in a MC-file)
3254
3255
3256
3257 *** Version 0.3 (2001/04/23)
3258
3259 - Many demo macros added
3260
3261 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3262
3263 - Hillas Calculation added
3264
3265 - Standard image cleaning available
3266
3267 - MReadTree is now able to handle more than one file
3268 (Remark: of the same structure)
3269
3270 - Now we are able to display events in a first version of the
3271 Camera event display. To do this we must run the macro
3272 "macros/readCT1.C" to read data from CT1.
3273
3274
3275
3276 *** Version 0.2 (2001/01/24)
3277
3278 - First Implementation of a Gui to read the raw data. Start the
3279 gui with the command mars.
3280
3281
3282
3283 *** Version 0.1 (2000/12/20)
3284
3285 - First official release 0.1
3286
3287 - Changes:
3288
3289 + changed calling style of MRawPixelIterator from do...while to
3290 while-loop
Note: See TracBrowser for help on using the repository browser.