1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 ;showplot:
13
14 * If a file without a MStatusArray is opened all object (not just
15 canvases) found in the file are drawn. Note that this may result
16 in empty tabs.
17
18 ;ceres:
19
20 * The night sky noise is now scaled with the sensitive area and
21 is given in units per square centimeter
22
23 * Added the possibility to add a cut after the image parameter
24 calculation (''Cut'')
25
26 * updated the PDE of the GAPDs with a more reliable curve from
27 the meeting page (linear extrapolate below 350nm)
28
29 * The impact distribution in the event distrbutions is now
30 perpendicular to Alt/Az and the histogram is displayed in 1D
31
32 * The GAPD PDE has been updated
33
34 * PDEs and mirror reflectivities have been linearily extrapolated
35 to match the wavelegth range between 290nm and 900nm
36
37 * There is no default pulse shape anymoe it must be given in
38 the resource file
39
40 * Fixed a bug which caused the aerosol coefficient to be incorrectly
41 initialized. The effect might be random but seems to be small.
42
43 ;callisto:
44
45 * Fixed a bug which prevented MAGIC Monte Carlo file from being
46 calibrated (ceres files worked)
47
48 ;star;
49
50 * allow to run thru even if discriminator threshold are missing
51 (they are not used for analysis so far anyway)
52
53 ;ganymed:
54
55 * added new starguider calibration for sequences since 1000534
56
57
58
59== Version 2.3 (2009/03/07) ==
60
61 ;SUGGESTION
62
63 * There is no need to re-run any data because no change took place which
64 could have an effect on the output. However, if you want a
65 meaningful SrcPos plot for your MCs in sponde you must re-process
66 star for your MCs first.
67
68 ;REMARK
69
70 * File produced with this release containing a camera geometry (which
71 are basically all files were produced as default) will not be readable
72 by older releases.
73
74 ;general
75
76 * fixed a few small bugs which could cause the display to crash in ganymed
77 and sponde
78
79 * in sequence file the date can now be omittet. In this case the
80 leading date with the underscore is missing in the expected filename
81
82 * the geometry class now also supports other geometries than just hexagons
83
84 ;automation
85
86 * added magnetic field Azimuth direction (ARRANG), currently
87 at ~ -7deg at La Palma
88
89 ;database
90
91 * plotdb.php: added default (sequences) for startup, added possibility
92 to set size of plot
93
94 * added a new table ''RunDataCheck'' which containes the rates after
95 image cleaning for every run which succeeded star. It can be
96 plotted using ''plotrundb.C''
97
98 ;merpp
99
100 * added support for Arehucas Version >= 200812140
101
102 * added support for Arehucas Version >= 200809030
103
104 ;mars
105
106 * The display now also displays the trigger pattern
107
108 * The display can now display ceres reflector (_R_) files
109
110 ;ceres
111
112 * added a uniformly distributed one-bin time jitter for the start of the
113 digitization. Otherwise the first photon would be digitized always with
114 the same alignment to the bins
115
116 * Added a plot showing the production height of the photons
117
118 * Moved the particle id from the event header to the run header
119
120 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
121
122 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
123
124 * Added many new options to control the tasks. For deatils see ''ceres.rc''
125
126 * Removed obsolete plots in pedestal and calibration mode
127
128 * Removed the non-NightSky photons from the plots where they are just
129 disturbing
130
131 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
132
133 * The daq event number now represents the readout number
134
135 * The camera ''electronics'' can now be ''switched off''
136
137 * A new tab ''Info'' now display basic things like the reflector
138 layout
139
140 * Improved reading speed for corsika files
141
142 * Improved memory handling (if a large ampount of memory was needed
143 for a single event all further events were stored in the same
144 memory and it was never freed, so the program took this memory
145 until the end)
146
147 * Converted the code from MMCS' reflector program to MSimAtmosphere
148 (instead of the tables build in for MAGIC Winter and Summer
149 atmosphere we use the values written by Corsika fitted to the
150 tabulated atmosphere given as input)
151
152 * For caluclating the displayed image parameters in ceres a basic
153 image cleaning removing isolated pixels is now done.
154
155 * The magnetic field direction (ARRANG) is now taken into account
156
157 * Added plot for the energy threshold after trigger ''Threshold''
158
159 * Added plot for the effective collection area after trigger ''TrigArea''
160
161 ;star
162
163 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
164
165 * The definition of fConcCore has slightly changed. The numbers
166 might decrease a little bit (the effect should be rather small)
167
168 ;ganymed
169
170 * added pointing model 328198
171
172 ;sponde
173
174 * The SrcPos plot for your MCs was so far meaningless because it just
175 displayes the MSrcPosCam data from the input star-files. Unfortunately,
176 this containes was never written to the star-files yet.
177
178 * A new Tab 'OnTime' is available which is an effective on-time
179 fit as in star but for all data. This is mainly for manual cross-check
180 of the effective on-time
181
182 * In some circumstances it might be necessary to re-calculate the
183 eff. on-time from the fit in the new tab, e.g. when a zenith distance
184 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
185
186 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
187 it to its own output file (for convinience)
188
189
190
191== Version 2.2 (2009/01/30) ==
192
193 ;SUGGESTION
194
195 * This release doesn't contain a major change which is expected to
196 change your results. Nevertheless there are small changes to
197 the calibration which can effect at least the first few hundred
198 events in any (mainly MUX and even more SUM) sequence a little bit.
199 So it is recommended although not necessary to reset your sequences
200 in the database before further processing.
201
202 ;NEW
203
204 * A first implementation of a Monte Carlo simulation program
205 (ceres - Camera Electronics and REflector Simulation) has been
206 implemented. It can simulate a full telescope already including
207 a complete reflector simulation and a flexible trigger and readout
208 simulation. Currently, no perfect setup is implemented and
209 especially the output of the program (data structure) should
210 be considered alpha state. Also the user interface is not yet
211 ready.
212
213 ;general
214
215 * All command line options after -- are now interpreted as
216 arguments (usually everything which doesn't start with a minus)
217 rather than options (usually everything which starts with a
218 minus). This allows to use file names starting with a -
219
220 * In all resource files you can now initialize the random number
221 generator. For details see: MJob::InitRandomNumberGenerator
222
223 * added a new program called ''readcorsika''. It's purpose is (in analogy
224 to readraw and readdaq) to read a Corsika output file (for now
225 only cherenkov output is supported) and print its contents in a
226 human readable form. It can also write the contents of this file
227 into a root-file.
228
229 * The calculation of the maximum distance to the origin in a MGeomCam
230 has been improved (edges might be further away than the sides).
231 This is just a tiny change but it might change the appearance of
232 the radial profiles a little bit.
233
234 * The default binning of the center-of-gravity plot has slightly been
235 increased
236
237 ;Database
238
239 * Added informations about the DC currents (fMinCurrents, fMedCurrents
240 and fMaxCurrents). The values are retrieved from the plots showing
241 the average DC currents of all pixels versus time.
242
243 * Websites with tables have now the opportunity to remove lines
244 ('-' button at beginning of each line) and get all lines back
245 ('+' at top of the column)
246
247 * Websites: added option to query only sequences containing sumtrigger
248 events
249
250 * Websites: added option to group by date (year, month, night) for runs
251 and sequences and enabled that combining of different group-bys,
252 e.g. status, date and source is possible
253
254 ;automatic analyis
255
256 * Rewritten producing plots in the web.
257 New plots, namely the output of plotoptical.C (extinction curve from
258 KVA), plotstat.C (status of the automatic analysis (percentage of
259 processed, analysed data etc.)) and plotusage.C (statistics of the
260 condor usage in the data center) has been are available now next to the
261 plots of plotdb.C
262 Mean values from the plots (output of the macro) are provided in a
263 txt file now.
264 The creation of the plots for callisto, star and ganymed in the web is
265 now steered via database. Consequently the plots are faster and
266 reliable up-to-date.
267 For all plots, a new layout is available facilitating the browsing
268 through the plots and providing additional information on the
269 displayed values. (tabs.php) These plots are linked from the DB
270 websites and the wiki.
271
272 ;statusdisplay
273
274 * The ''Loop'' entry in the menu bar now contains an option to pause
275 the loop and to process single events.
276
277 ;merpp
278
279 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
280 instead of RunHeaders)
281
282 * Now allows to merpp files newer than 2008/09/03.
283
284 * Added fixes for wrong (wrong or double) run- and file-numbers
285 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
286
287 ;callisto
288
289 * Extracting the pulse position for the pulse position check events
290 with sum trigger were denied. This decreased the statistics
291 extremely and therefor the resulting puse position was calculated
292 quite weak. Now sum events pass the calculation if and only if they
293 have also a level 1 trigger.
294
295 * the extraction of pedestal events and pulse position from the
296 first data events is now more automatic and makes sure that
297 a more precise number of events is extracted independent of
298 the ratio with which pedestal events or events with signals
299 are contained in the data.
300
301 * Updated Muon calibration constants for all MUX data (teh changes were
302 all smaller than 5%)
303
304 ;star
305
306 * For the calculation of the effective on time all sum-triggered events
307 were skipped. Now all Level1-triggeres events will pass. This might
308 result in a slight inaccuracy of the effective on time.
309
310 ;ganymed
311
312 * If the source position is more than 1deg away from the camera
313 center an error is raised now.
314
315 * Hopefully fixed the bug ''ganymed crashes when resized''
316
317 ;sponde
318
319 * Fixed a problem which causes the fitted spectral slope to be displayed
320 incorrectly. If you use MJSpectrum::FormFlux in your macros make
321 sure that the parameter 0 of your fit is negative.
322
323 * Added a histogram showing the read source position of your MCs
324
325
326
327== Version 2.1.1 (2008/08/04) ==
328
329 ;Database
330
331 * Added the median number of photo electrons from the calibration
332 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
333 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
334
335 * Added fTotOnTime, which is the on-time as given by the run-headers
336 (in contradiction to fAbsOnTime which comes from CC)
337
338 * Added new primaries for the new data structure (Magic II): for the
339 tables dealing with sequences (SequenceBuild Status, Sequences,
340 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
341 this is the telescope number (fTelescopeNumber) for the tables dealing
342 with runs (RunData and RunProcessStatus) this is in addition the file
343 number (fFileNumber)
344
345 * Added column fPriority to the status tables to be able to steer the order
346 in which the data is processed. As default the run, sequence and dataset
347 number are used.
348
349 ;automatic analyis
350
351 * Adapted scripts to the new data structure: They can handle now different
352 telescopes (getting the information as usual from the database).
353 The paths for Magic 2 are not yet implemented.
354
355 ;general
356
357 * should work now with root 5.20/00 (please note that root 5.20/00
358 we encounter crahses in the status display which are ot yet
359 understood)
360
361 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
362 instead of the base name of the file. This makes them easier to
363 access from the code
364
365 * Default Monte Carlo names in MSequence do not require the _E at
366 the end anymore
367
368 * where abrrevating a sequence file with a sequence number is possible
369 also "telescope:sequence" is now accepted, e.g.:
370 star 2:2000123 --out=output
371 see the programs' help for more details.
372
373 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
374 from the database. See the constructors for more details.
375
376 * MReadTree now supports friends
377
378 * MReadTree can now read also files not written by MARS and store
379 the data encapsulated in emulated MParContainers
380
381 * added a new starguider calibration valid since 15.1.08
382
383 ;showplot
384
385 * showplot can now read more than one file at once. This is especially
386 inetersting if reading files containing pure canvases
387
388 ;merpp
389
390 * we merpp the dc currents now also from the camera reports (they have
391 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
392
393 * In the automatic analysis we omit merpping of the currents from the
394 caco files and use the lower rate camera reports from the cc files
395 instead
396
397 * merpp has been redisigned to allow merpping of the cc-reports
398 of a whole sequence. This allows to design a very simple analysis:
399 mkdir output
400 ./callisto 100776 --out=output
401 ./merpp 100776 output
402 ./star 100776 --ind=output --out=output
403 Instead of the sequence number also sequence files are accepted.
404
405 * Implemented a fix for run-numbers between 1001348 and 1001396
406 which were incorrectly assigned by the cc.
407
408
409 ;callisto
410
411 * added a filter again which was was removed in the last release.
412 it removed the most brightest events. This should not change
413 any analysis result because these events are so bright that
414 they cannot be analysed anyway, but the bad-pixel plots doesn't
415 show outliers.
416
417 * updated muon calibration constants for the periods 51-57,
418 58-63 and 67-
419
420 ;star
421
422 * The camera currents are now displayed with the rate of the camera
423 reports instead of the caco reports
424
425 ;ganymed
426
427 * if mc camera files are new enough (>=8) the source position in the
428 camera is now calculated from the stored telscope and shower
429 orientation (Note, that this might not be suitable in all cases
430 depending on the aim of the study. These case still needs
431 implementation)
432
433
434
435== Version 2.1 (2008/06/18) ==
436
437 ;Database
438
439 * introduced average temperature and wind speed from star-files
440
441 * introduced average values from Pyrometer (mainly Cloudiness)
442
443 * introduced the ratio of accepted calibration events in the
444 calibration run
445
446 * introduced the average rates of the different trigger pattern,
447 e.g. the rate of pedestal and calibration events, from the signal-file
448
449 ;general
450
451 * fixed GroupBy options in plot*.C macros
452
453 * only display KVA points (not the Tuorla points) in plotoptical.C
454
455 * all programs now allow to add resources to the ones from the resource
456 file or overwrite them from the command line. This can be done like this
457 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
458 if something seems to be wrong you can debug what the program is doing
459 using the option --debug-env=3
460
461 * increased the diversity of debug levels. That also means that with -v3
462 you get now less output, i.e. only the output which is important for
463 an analysis. To get more output which helps for debugging try 4, 5 and 6.
464
465 * fixed a problem in the task synchronizing the reading of the reports
466 and the data stream. The effect was that in some circumstances the last
467 events of some trees could have been skipped. Since this is only a
468 very tiny part of the data no severe effect to your analysis results
469 is expected (an exception might be very short, i.e. singel runs,
470 datasets).
471
472 * Dataset file now allow to include the sequence file directly within
473 the dataset file and also allow to exclude single runs from the dataset.
474 (for more details see Class reference of MDataSet)
475
476 * Sequence files now allow for excluding runs from the analysis
477 (for more details see Class reference of MSequence)
478
479 * added code to process the sum-trigger flag
480
481 * the histogram classes MH3 and MHn now support profile histograms
482
483 * the histogram classes MH3 and MHn now support labels at the axis
484
485 * the Random Forest Train-classes (MJTRain*) now store the used datasets
486 in the output file
487
488 * the MFMagicCuts have a new option to allow a linear area cut (for
489 special studies)
490
491 * The liniking of the shared object is now done into a file defined
492 by 'mktemp'. This should be a local file system which accelerates
493 liniking a lot.
494
495 * The code has been prepared for compilation with root 5.18/00d
496
497 * The MHEnergyEst histogram now shows the distribution of
498 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
499 and (Eest-Emc)/Emc vs Emc.
500
501 * fixed mars (event display) for merpped raw-data and MC data
502
503 * adapted the synatx of sequence files to allow for the new run/file
504 scheme. For more details see class description of MSequence
505
506 ;showplot
507
508 * Added support for tiff files
509
510 * Added support for csv files (tables containing tab number,
511 name and title)
512
513 * Tabs now can have a title which is displayed in the postscript file
514
515 * When multiple file are written at once (e.g. pngs from a display)
516 it is now possible to use the tab name and or tab number in the
517 file name. For details see showplos's help.
518
519 ;merpp
520
521 * Implemented cc file version 2008-02-20/0
522
523 * Implemented cc file version 2008-05-19/0
524
525 * With new options merpping can be restricted (in addition to the
526 run-number) also by telescope and file number.
527 For details see "merpp --help"
528
529 * Implemented raw data format 11 (the most important change, except
530 from plenty of changes in the format definition, is the addition
531 of the file-number in the header) If nobody makes a mistake this
532 format should have the advantage that it is by definition forward
533 compatible, so old programs will be able to read newer formats.
534
535 * Added Pyrometer information to default output (stored in a new Tree
536 Pyrometer, needs a complete new merpp, i.e. new calibration)
537
538 * Merpping (also update) can now be restricted to one single report.
539 For example:
540 If you want to update an old file with Pyrometer information call
541 merpp --only=Pyrometer --update
542
543 ;callisto
544
545 * in the pedestal processing now at least 50 processed events are
546 required for succeeding.
547
548 * the signal and calib files now contain also the sequence information
549
550 * the two MPedestalCam in the calib file now have proper names
551 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
552
553 * Both pedestal cams now contain the number of events processed
554
555 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
556 i.e. for the extraction of the calibration pulses basically the average
557 over all events of the first slice instead of all slices was used.
558 Since pedestal and calibration constants are continously recalculated
559 this only effected the very first events of every sequence.
560
561 * For the extraction of the position of the maximum sample now the
562 extraction range is set automatically to the extraction window,
563 before the whole accessible range was used.
564
565 * If the number of samples in the events and the number of samples
566 in the run-header disagrees now an error is raised (this can
567 happen in not well simulated Monte Carlo files)
568
569 * In the case of MUX-data pedestal events with the lvl1 trigger flag
570 could survive into the pedestal calculation -- fixed.
571
572 * Tab "TrigPat" added showing the distribution of the trigger pattern
573 as found in the run-files (normalized with the run length)
574
575 * The selection of events from the trigger pattern has been improved.
576 If the trigger pattern is corrupted events won't pass anymore.
577
578 * Added a new command line option --dev-null to suppress output of
579 Y-files (this is useful for test cases)
580
581 * added a new tab "CalPos" showing the arrival time of extracted
582 interleaved calibration events
583
584 ;star
585
586 * the star file now contains also the sequence information
587
588 * Added a new command line option --dev-null to suppress output of
589 I-files (this is useful for test cases)
590
591 * Tab "Rate" added showing the distribution of the trigger pattern
592 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
593 the Y-files (normalized with the run length)
594
595 * The effective on-time calculation doesn't use events with only
596 sum-trigger anymore
597
598 * The data in the MHWeather tab has been reorganized. The never
599 working solar radiation has been removed and the data from
600 the pyrometer (cloudiness, air and sky temperature) is
601 displayed in addition.
602
603 ;ganymed/sponde
604
605 * Now data points are even shown correctly if they have error bars larger
606 than one sigma. Points with null or negative significances are omitted.
607
608 * DrawNicePlot now allows to set a projection range
609
610 * Updates pointing models. One is applied after the implementation
611 of the new LUTS in August, the other one is applied after the
612 next major change of the pointing model in October. Note that
613 these models are preliminary and give wrong results below Zd=65deg
614
615 ;sponde
616
617 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
618
619 * a new option "--force-runtime" is available. In case of very short
620 datasets (for light-curves) which are in the order of a few
621 minutes the calculated effective on-time is not very acurate because
622 it is quantizised in the order of a minute. Therefore you can switch
623 to using the real run-time instead (remakrt: this ignores any
624 dead-time!)
625
626 * a more analytical way is used to "fill" Monte Carlos into regions
627 of impact parameters which have not been simulated because the
628 trigger efficiency is assumed to be 0.
629
630 * estimated sensitivity curves for hi and lo zenith angles are shown
631 scaled to the correct observation time and collection area
632
633 * the Monte Carlo events after cuts are now written to the output file
634 if an output file given
635
636
637
638 *** Version 2.0 (2007/09/03)
639
640 - database: the position used for the pulse pos check was missing
641 in the callisto output and could thus not be filled into the DB.
642 Also the old values seemed not exactly the PulsePos used for
643 teh check.
644
645 - general: Resource file now allow an Include-Resource, i.e. you can
646 read a resource file with default settings, include it in your
647 resource file and overwrite the settings in your file. More than
648 one include file is allowed. Inclusions can be iterative.
649 Include: mydefaults.rc yourdefaults.rc
650 The resources in the first file have higher priority than the
651 second file.
652
653 - general: Now the output files (calib*.root, etc) also contain the
654 resource file (to check it open it in the TBrowser and choose Print()
655 from the context menu)
656
657 - general: Dataset files now allow to overwrite the default path
658 to search for sequence and data files. Note, that the program
659 option and individual resources will overwrite it. For example:
660 SequencePath: /magic/montecarlo/sequences
661 DataPath: /magic/montecarlo/star
662
663 - general: Fixed a problem with variables in MDataPhrase. It seems
664 that only optimdisp (didn't work) was effected.
665
666 - general: Some improvements to the optim and train processing. For
667 example the ststud window now got a proper title.
668
669 - general: The "Status Display: " was removed from the window title
670 within an Eventloop.
671
672 - general: added a new flexible histogram-class (MHn) which can be used
673 for example in testing after optimizations or training to produce
674 user defined histograms.
675
676 - general: The Random Forest now allows attaching an evaluation
677 function which is applied to its output. This allows to train
678 on whatever you like (eg. train on log10(energy), but return
679 energy)
680
681 - general: The Random Forest training of energy (trainenergy.c) and
682 disp (traindisp.C) has been improved by more graphical output to
683 judge the result.
684
685 - general: The training of energy (trainenergy.C) has been improved
686 a lot by training on a different quantity than energy. It gives
687 a result which is highly independant of the source spectrum
688 and shows lower bias than all other options.
689
690 - general: Dataset files are allowed to contain collections of
691 datasets. For more details see the class reference of MDataSet.
692
693 - general: The default WobbleMode in a datset file now (if not
694 overwritten) is "auto", i.e. wobble mode is set if the dataset
695 doesn't contain off-sequences.
696
697 - merpp: Merpp can read file format version 9 now. Please realize
698 that for file format version 9 the extraction range is different
699 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
700 the first and last 15 slices have been removed from all MUX data.
701
702 - mars: Similar to writing movies you can now select events which
703 should be displayed in your display. Therefore add the following
704 lines to your mars.rc:
705 MFEvtNumber.FileName: ganymed00223552.root
706 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
707 The input file can be a ganymed-file after (ganymed*.root) or
708 before (ganymed*-summary.root) file. For example to select all events
709 from your on sample after cuts (excluding the ThetaSq cut) use
710 MFEvtNumber.Selector: DataType.fVal>0.5
711 To show all events from your on-sample after quality cuts
712 use the summary file instead.
713
714 - mars: new ways to call mars are implemented. Instead
715 of calling
716 mars filename.root
717 you can now also use
718 mars sequence.txt
719 or
720 mars sequence.txt inputpath
721 or replace sequence.txt by the sequence number if the default
722 sequence file should be used.
723
724 - mars: The default size has been increased
725
726 - mars: There are two new heckboxes which allow to switch off
727 the calculated image parameters
728
729 - callisto: was broken for MCs... fixed.
730
731 - callisto: improved calculation of spline coefficients a lot. This
732 leads to a further improvement of the event rate calibrating MUX
733 data of about 15% (175evt/s instead of 150evt/s)
734
735 - callisto: finally the raw data we read is now real 16bit (with
736 10bit precision) for MUX data and not a stripped 8bit number
737 anymore. Due to scaling of the numbers (without precision loss
738 into an [0-256[ range, the final numbers for pedestal, pedestalrms
739 and extacted signal don't change. However, at all places where
740 raw data is directly accessed (eg. saturation and variation
741 limits in the signal- and pedestal-extraction) the numbers
742 refer still to the data's 16bit range.
743
744 - callisto: The maximum arrival time difference used in the bad
745 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
746 for both, old FADC and MUX-FADC, data.
747
748 - callisto: Be aware that callisto is now calibrating the arrival time
749 in nanoseconds rather than time slices. Also all following tasks
750 have been changed to assume ns units now. If you star data
751 calibrated with an older version it might be necessary to adapt
752 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
753 to obtain optimal results. The plot in the PulsePos tab
754 will now be in ns, too. This might also mean that the Muon
755 analysis in star might not work as perfect as expected as long
756 as old files read in.
757
758 - callisto: The calibration constants of earlier updates got lost
759 somehow. All constants have been updated.
760
761 - star: The PSF is now determined from the profile of the ArcWidth
762 instead of arcwidth/radius. The old way gave to much weight
763 to the bins with low statistics. The reference lines have been
764 updated.
765
766 - star: For speed reasons events suitable for the muon analysis
767 are now also preselected by fConcCOG<0.1 which seems to be a very
768 good preselector for muons.
769
770 - star: is now calculating a new timing parameter the Slope along
771 the major and minor axis of the shower. Therefore a numerical
772 solution of a line-fit is used. To use MHillasExt.fSlopeLong
773 and MHillasExt.fSlopeTrans don't forget to multiply it with
774 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
775
776 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
777 have been removed from MNewImagePar. They have never been good for
778 anything.
779
780 - star: Implemented a new recursive algorithm which is supposed to be
781 faster. Also implemented new cleaning oiptions, which are:
782 + CleanLevel0:
783 The cleaning level above single core pixels can be kept
784 + KeepIsolatedPixels:
785 Define whether single core pixels should be kept
786 + TimeLevel1:
787 The coincidence window in nanoseconds to single used neighbors
788 + TimeLevel2:
789 The coincidence window in nanoseconds to two used neighbors
790 + PostCleanType:
791 MOde in which a time dependent post cleaning should be applied
792 0: No post cleaning
793 1: Require for each used pixels at least one used neighbor
794 within a time-window of CleanLevel1
795 2: Require for each used pixels at least two used neighbor
796 within a time-window of CleanLevel2
797 3: Require first two and second one used neighbor
798 within a time-window of CleanLevel1 and fCleanLevel2
799 respectively
800 + RecoverIsolatedPixels:
801 - recoveres isolated core pixels if they have a used neighbor
802
803 - mars/star: The new default cleaning is:
804 + CleanLevel1: 6.0
805 + CleanLevel2: 3.0
806 + CleanTime1: 1.75
807 + CleanTime2: 1.75
808 + PostCleanType: 3
809
810 - star/ganymed: The old spark-cuts have been replaced by new ones.
811 These new spark cuts have been cross checked with the sequences
812 84720 (before splitter), 101041 (after splitter) and 223539 (new
813 FADCs). In all cases they seperate pretty well, but of course not
814 perfect. Monte Carlos have suggested to tighten the cuts a little
815 bit further at low sizes. This has been done.
816
817 - ganymed: IMPORTANT - The spark cuts have been changed to match
818 all available data more or less well. This might mean that for
819 YOUR data there are still sparks visible.
820 Whenever you do an analysis you have to make sure that NO sparks
821 survive your cuts!
822
823 - ganymed: The old hadronness and size cuts have gotten new indices
824 (10, 11). The old indices 8 and 9 now mean an additional condition
825 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
826 If you want to switch off this cut just move the line far away enough,
827 e.g. by setting c[9] to -500. Please update your ganymed.rc files
828 accordingly!
829 The unit of c[9] is deg. It is the dist at which your cut will
830 cross the slope==0. The unit of the slope is ns/deg. So if
831 you readin files calibrated with an older Mars-version you
832 have to adapt the default value for c[9] to the FADCs:
833 - Multiply by two for the MUX FADCs (run number > 200.000)
834 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
835 - Multiply by 42 for the meaning of life (run number = 200.000)
836
837 - ganymed: The old Cut0 is now called CutQ and is calculated before
838 the source position is caluclated. If you need a quality cut
839 including source dependant data (be very carefull with this!)
840 you have to use Cut0 instead.
841
842 - ganymed: now properly supports three off regions in wobble mode.
843 It will be the default from now on in ganymed_wobble.rc. To change
844 the number of off-regions use
845 NumOffSourcePositions: 1
846 in your ganymed.rc. Also by default no off-theta cut will be done
847 anymore so that you will get a background level higher than the
848 signal level in your ThetaSq plot for ThetaSq>0.2.
849 Due to this be carefull changing the scaling mode away from
850 "None". You will underestimate your signal if your scale interval
851 is not properly set.
852 (Rem: ThetaSqN is no longer needed)
853
854 - ganymed: is now storing the events of all (on- and off-)
855 source positions even in the case of more than one off-source
856 position. This should allow sponde to work properly and the
857 energy estimation is done correctly in all cases (without any
858 "nearest position" trick)
859
860 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
861 with a real pointing model for the starguider is done, calibrated
862 with more than thousand tpoints taken from this date on.
863
864 - ganymed: was broken for Wobble-MCs... fixed.
865
866 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
867 has changed. Note that your old ganymed.rc will be incompatible
868 with the new algorithms! Please check the ganymed.rc files and
869 the class description of MFMagicCuts for more information.
870 It is recommended at the moment to use identical Disp-Parametrizations
871 for on/off- and wobble-mode. If cuts are optimized only
872 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
873 should be optimized. All other values should be kept as they are.
874 If you want to do an anylsis without timing a parameters, you can
875 switch off the timing cuts by seeting parameter 7 to a very small
876 value (eg. -99). To remove the slope parameter from the disp
877 paremtrization set parameter 8 to 0.
878
879 - ganymed: The distribution of observation time versus zenith
880 angle is now shown for off- AND on-data.
881
882 - ganymed: The contents of the source position plot are no longer
883 averaged, thus a lot of (fake) events between the two wobble
884 positions have disappeared.
885
886 - ganymed: There is a new tab "CutT" it contains the VsSize plots
887 with the CutT, whihc is defined in ganymed.rc, applied. It
888 is resonable to use your theta-cut for it, to see if there is
889 something strange (sparks!) in your signal-region.
890
891 - ganymed: To choose a dataset from a collection in a dataset file
892 use the new command line option "--dataset=12345"
893
894 - optim, sponde: should now properly support three off-regions.
895 Just produce your ganymed summary files with three off-regions.
896 optim and sponde will automatically get all off events from
897 all off-regions from this file. Please do not forget to
898 set the scaling in optimwobble.C properly:
899 fit.SetScaleUser(1./3);
900 it is not yet read in automatically (will follow soon).
901 In the case of fixed Scale you can also use
902 cuts.SetThetaCut(MFMagicCuts::kOn);
903 no off-cut needed.
904 Be carefull in case of three off-regions when switching on
905 scale mode. Make sure that the scale interval is set correctly.
906
907 - sponde: sponde.rc and sponde_onoff.rc are now idetical
908
909 - sponde: the resouce files have been rewritten with a lot of
910 comments and a well working parametrization for an energy estimator
911
912 - sponde: In the estimated energy versus monte carlo energy plot the
913 contents where exchanged.... fixed.
914
915 - sponde: the so called "accurate"-mode has been removed. It didn't
916 give any improvement in accuracy, only decreased execution speed.
917
918 - sponde: the so called "simple"-mode has been removed. It didn't
919 give any improvement in simple.
920
921 - sponde: the so called "refill"-mode has been removed. It was anyhow
922 not implemented.
923
924 - sponde: now checks whether the theta distribution of your on-data
925 and the theta-distribution of your Monte Carlo sample (after
926 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
927 sample is incomplete) execution is stopped. Execution can be forced
928 using the new option --force-theta. Use this option with care!
929
930 - sponde: Proper collection areas can now be constructed also from
931 Monte Carlo samples generated with different maximum impact
932 parameters. Note that in previous version you neither got
933 a warning or failure, nor was there any obvious sign that the
934 collection area was overestimated due to usage of files with
935 different maximum impact parameters.
936
937 - sponde: If MC files with different lower energy limits are used
938 the primary MC spectrum is artificially completed down to the
939 lowest energy used at all. WARNING: that this gives correct
940 collection areas ONLY if none of the events in this region would
941 survive your cuts at all.
942
943 - sponde: the output file now contains more information about
944 the spectrum (eg. the full 2D collection area histogram).
945 Note, that this information can only be written to the file
946 if it is stored automatically via command line argument.
947 If you only store the status display from within the display
948 the information is lost.
949
950 - sponde: added a new tab "Disp". It shows the residual of the disp
951 (Disp-Dist) versus several parameters and it is meant to judge the
952 quality of the disp estimator. In the ideal case the residual is zero
953 and doesn't depend on any variable. The tab is displayed after
954 CutQ and Cut0.
955
956 - sponde: added a new tab "Energy". It shows the residual of the
957 energy (lg(estimated energy)-lg(monte carlo energy)) versus
958 several parameters and it is meant to judge the quality of the
959 energy estimator. In the ideal case the residual is zero
960 and doesn't depend on any variable. In reality even a good estimator
961 can show residuals versus Monte Carlo energy. The tab is displayed
962 after all cuts.
963
964 - sponde: added a new tab "EventDist" showing the unweighted real
965 absolute number of events of your sample after cuts. This tells
966 you how many events with this energy you had in your MC files.
967 The same information you get from the error bars of the weighted
968 histograms, but this is less intuitive.
969
970 - sponde: The spectrum plots now show the crab- and 1553-spectrum
971 for comparison. It is not meant to show these curves in
972 publications, they are only for production.
973
974 - sponde: The OriginalMC tree with the events produced by corsika
975 is now processed only once
976
977 - sponde: Finally fixed most annoying bug, which has effected the
978 last bin of the collection area. It was the problem that binnings
979 of root histograms are from 1 to n (included) but there was a C-like
980 loop in sponde from 0 to n (excluded). Now the loop also includes
981 correctly under- and overflow-bins. The worse thing with this is,
982 that for the events in the highest bin not only the bin-content
983 was wrong, but also the weights applied to these events, which could
984 in pricipal effect also other parts of the distribution (eg. due
985 to energy estimation). Fortunately it effected only a few events
986 in most cases.
987
988
989
990 *** Version 1.2 (2007/05/14)
991
992 - database: The database now has two new values Unsuitable50 and
993 Unsuitable01. They express the number of pixels which are
994 unsuitable for more than 50%, respectively more than 1%, of
995 all calibrated event. It is a more accurate number than the
996 previously used numbers, because they only take the first
997 calibration (ignoring the interleaved calibrations) into account.
998
999 - database: The database now has two other new values UnsuitableMax and
1000 DeadMax. They express the maximum number of pixels which were
1001 unsuitable, respectively dead, during the sequence. Because
1002 of high pedestal rms (cars passing) a few events with very high
1003 numbers of unsuitable pixels can happen. Not to suffer from this
1004 effect we don't take the highest 0.1% of the numbers into account.
1005
1006 - general: fixed a bug which caused callisto and star to stop working
1007 properly because the callisto output was currupted
1008
1009 - general: a script called scripts/makemovie has been added which
1010 simplified the process of producing several movies from a single
1011 sequence with different setup.
1012
1013 - callisto: Some more code cleanup. Started to remove old obsolete
1014 code from cvs.
1015
1016 - callisto: The extraction of the pedestal with the extractor was
1017 not random. It seems that extracting at one position is still biased
1018 (for example in the first or last slices we could still suffer from
1019 switching noise) Now it is completely random.
1020
1021 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1022 pedestal files) individual pixels could be skipped due to high
1023 variations. This was already the case for the pedestal extraction
1024 from the lo-gains since the beginning and properly handled
1025 there, but was introduced in the extraction from the pedestal files
1026 a while ago. To calculate the average value it was still divided
1027 by the number of events procesed not by the number of summands
1028 really summed. This let to a pedestal which was a tiny amount too
1029 small (for a few piels in the order of 0.1%). This led to an slightly
1030 positive offset of the randomly extracted pedestal for a few pixels.
1031 I doubt that this has a big effect on the result, because the effect
1032 on the individual numbers is quite small. Due to this it is suggested
1033 that you rerun your calibration to make sure you are without any
1034 avoidable bias.
1035
1036 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1037 the median rms of the absolute arrival time and expressed in significance
1038 levels. This replaces the old meaning of an abolute upper limit. An
1039 absolute upper limit doesn't make much sense, because in our data
1040 all arrival times are shifted at the same time (in fact it might be
1041 a shift of the artificial trigger w.r.t. to the light flash).
1042
1043 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1044 of the number of unsuitable pixels over the whole sequence. This
1045 is usefull mainly to judge if an intermediate calibration had
1046 problems.
1047
1048 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1049 of the number of dead pixels over the whole sequence. Dead pixels
1050 in this context are unmapped pixels, i.e. pixels which could not
1051 be interpolated, and thus are ignored in the further analysis.
1052
1053 - callisto: It is now possible to use the position of the maximum
1054 of the spline as arrival time instead of the leading edge even
1055 when using the integral for the signal. Therefor set the extraction
1056 type to kIntegralRel ("IntegralRelative") and the relative height
1057 ("HeightTm") to -1:
1058 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1059 MJPedestalC1.ExtractSignal.HeightTm: -1
1060
1061
1062
1063
1064 *** Version 1.1 (2007/04/27)
1065
1066 - general: The new class MGeomCamDwarf contains the camera geometry
1067 for our prefered Dwarf camera and can be used to create general
1068 geometries of roundish or hexagonal cameras.
1069
1070 - mars: The default cleaning is now abolute 8.5/4.0.
1071
1072 - mars: The resource file mars.rc now contains examples for MUX data
1073
1074 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1075 data containing only 10-bit information is still cooked down to
1076 8-bit, by cutting away the lowest 8-bit.
1077
1078 - merpp: When reading raw data the data is now stored in a single
1079 array. The lo-gain array is obsolete. The interface stays the same.
1080
1081 - callisto: To process the new MUX data use the resource file
1082 callisto_mux.rc
1083
1084 - callisto: The -root and -raw options to read merpped raw data have
1085 been removed
1086
1087 - callisto: If the -mc option is given the sequence-name can now be
1088 replaced by the MC sequence number
1089
1090 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1091 -mc option can now be omitted
1092
1093 - callisto: Started further simplification by removing obsolete
1094 dependancies on MCalibIntensity*Cams.
1095
1096 - callisto: removed unsused intensity calibration from MJCalibration
1097 for further simplification
1098
1099 - callisto: for simplification removed references to
1100 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1101 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1102 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1103 (this should at minimum change nothing at all, and at maximum
1104 improve thing if these containers where somewhere not handled
1105 properly)
1106
1107 - callisto: Added the option to write an event movie. Please use
1108 this option with care (huge files) but exessively to understand
1109 our events. For further documentation please refer to the
1110 IACT wiki
1111 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1112
1113 - callisto: Improved binning for the pulse position check histogram
1114
1115 - callisto: The code calculating the pulse position checknow takes
1116 the pedestal into account
1117
1118 - callisto: The arrival time is now stored with full precision this
1119 helps to get rid of artefacts in histograms. For the signal this
1120 is not necessray because it is displayed in log-scale anyhow
1121
1122 - callisto: Fixed a problem with internal exclusions. Pixels which
1123 have once been marked as unsuitable didn't get the necessary
1124 histograms filled anymore to be rechecked with each interleaved
1125 calibration.
1126
1127 - callisto: The relative arrival time resolution (the rms of the
1128 relative arrival time offset) is now checked against its
1129 median and the median deviation, instead of the average
1130 plus an absolute offset.
1131
1132 - callisto: The relative arrival time offset is now calculated
1133 w.r.t. its median not w.r.t. to an artificial reference pixel.
1134
1135 - callisto: The relative time calibration now marks pixels with
1136 outlaying offset as unsuitable
1137
1138 - callisto: The interleaved relative time calibration has been switched
1139 on. The advantage is that pixels which are marked as outliers
1140 now can recover. An improvement over time is not expected, because
1141 the relative time calibration seems stable.
1142
1143 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1144 option can now be omitted.
1145
1146 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1147 or the option "-mc" is specified as default the monte carlo datacenter
1148 paths (/magic/montecarlo/...) are used if not overwritten in the
1149 dataset file.
1150
1151 - ganymed: The output files now contain run- and event-number for all
1152 events, accessible as RunNumber.fVal and EvtNumber.fVal
1153
1154 - ganymed: Added a plot showing the source position in the camera also
1155 for wobble mode
1156
1157 - ganymed: In addition to the existing task which can be setup to
1158 be executed after Cut1 a final task called "EstimateEnergy"
1159 has been added, executed before writing the final output
1160 (ganymed00000000.root). The task setup in all three cases
1161 can be choosen individually. (For all three(!) cases you
1162 can for example choose MRanForestCalc. For examples see all
1163 sponde*.rc and all ganymed*rc)
1164
1165 - ganymed: If a container "MEstimatedEnergy" is found in the
1166 parameter list (eg. because it was setup by MEstimateEnergy)
1167 it will be written to the output file.
1168
1169
1170
1171 *** Version 1.0 (2007/02/16)
1172
1173 - database: Website to plot values from the database has been added.
1174
1175 - database: The rate of spark events as found by star is now kept
1176 and the rate after cleaning is now with spark events subtracted
1177
1178 - general: The changes to the interpretation of phrases lead to
1179 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1180
1181 - general: Added example files how you can create your own calendar
1182 (eg. as christmas present) with Mars. Just run
1183 root macros/tutorials/calendar.C
1184
1185 - general: Added a possibility to display grouped data in the plotdb.C
1186 macro (and similar macros). This allows to plot hourly, nightly,
1187 weekly, monthly and yearly averages.
1188 For more details see the plotall function of the macro
1189
1190 - general: fixed the error display of the camera display. It showed
1191 wrong results.
1192
1193 - general: fixed a memory leak when reading many MStatusDisplays
1194
1195 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1196 between a spherical and a parabolic mirror
1197
1198 - callisto: We have a new pulse position check which takes the properties
1199 of the extractor automatically into account. So no need to set
1200 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1201 left is done. If possible the lo-gain extraction start and hi-gain
1202 extraction end is changed accordingly. If no proper extraction range
1203 can be set (hi-gain too much to the left) an error is raised.
1204
1205 - callisto: New swapped pixels have been found and corrected
1206
1207 - callisto: Redone the signal extraction this includes:
1208 + Unified the algorithms to extract the pedestal for all pedestal
1209 extractions done
1210 + Unification of hi- and lo-gain into one array
1211 + Unification of hi- and lo-gain extraction for Spline and
1212 Digital Filter (means now exactly the same algorithm is used,
1213 not a copy-and-pasted one)
1214 + Store pedestal subtracted data in a common place
1215 + Improved extraction algorithms. If the algorithms search a
1216 maximum but don't find one they don't return the maximum anymore
1217 + Improved the extraction such that a information for signal
1218 and time which is consistent is returned
1219 + replaced the numerical spline with a (not slower) analytical
1220 solution
1221 + Lowered the saturation limit from 250 to 245 to make sure that
1222 we are far away in all pixels from problems with the clock-noise
1223 + The start of the lo-gain extraction is calculated from the hi-gain
1224 arrival time. In case of saturation an estimation is used.
1225 + the hi-gain window was extended to slice 16. This allows extraction
1226 of very late pulses in single pixels or of huge hadron showers.
1227 + Now uses the lo-gain extraction range for pedestal extraction,
1228 not the hi-gain range in the lo-gain
1229
1230 - callisto: New hi-/lo-gain calibration constants have been produced
1231 for all periods from the statistic of the whole period. They are
1232 now used automatically depending on the periods. The old constants
1233 where deviation in avarega about 2%-3%. The constants are very
1234 stable from period to period (<<1%) except for exchanged channels.
1235 In a few cases the constants used so far were off by 1%-2% (maybe
1236 temperature effects?)
1237
1238 - callisto: To gain obsolete space we do not write the
1239 MPedestalFundamental anymore. Also calibration and bad pixel
1240 treatment is not done for it anymore because it has never been used.
1241
1242 - callisto: Fixed a bug in the seuqence handling which caused the
1243 light condition to be ignored
1244
1245 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1246 basically the same as "Cleaned" but the distribution devided into
1247 the events fullfilling a spark cut or being rejected by it.
1248 This cut can be changed from star.rc (see example inside) by
1249 the "SparkCut" directive
1250
1251 - star: Star displays now the average individual pixel-rate (IPR) versus
1252 time and the average discriminator threshold (DT) of all pixels.
1253
1254 - optim: fixed a problem with the optim-macros which was due to a bug
1255 in the new phrase parsing
1256
1257 - ganymed: To get a nice FalseSource plot (instead of the all-information
1258 debug plot displayed as a standard plot) use the context menu
1259 somewhere between the two upper plots, click on "DrawNicePlot"
1260 and enjoy the result. (It is the same context menu which contains
1261 the other options)
1262 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1263
1264 - ganymed/optim/train: The cut program, trainings- and optimization
1265 macros could run with less files found than expected from the
1266 sequence-files. No the execution is stopped in this case.
1267
1268 - ganymed: now stores the dataset in the output file with all information
1269 contained (as sequence number, sequence path, data path) so that the
1270 used dataset file can be recreated complete from the output
1271
1272 - sponde: now also allows the uasge of random forest
1273
1274 - sponde: added a plot showing the cut efficiency
1275
1276 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1277 errors (eg. effecting the collection area) because the errors of the
1278 two histograms were swapped in the calculation, which makes a difference
1279 in the case the histograms contains weighted events. Aditionally the
1280 totalarea was incorrectly taken into account, which results in too small
1281 errors, which makes a difference at low statistics were the errors
1282 or the collection area dominate.
1283
1284
1285
1286 *** Version 0.10.3 (2006/10/23)
1287
1288 - database: Implemented ObservationMode flag in websites.
1289
1290 - database: For sequences there is now also the stoptime available on the
1291 websites.
1292
1293 - database: Removed ManuallyChanged flag from sequence-info websites,
1294 as it is not needed anymore with the new sequence building algorithm.
1295
1296 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1297 Class for calculation of confidence intervals (upper limits).
1298 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1299 Please read the class instruction of TRolke for more information.
1300
1301 - general: The programs now return 0xfe if the requested resource file
1302 doesn't exist.
1303
1304 - general: Errors comming from root itself are now not output to
1305 stderr anymore but to our default (colored) log-stream.
1306
1307 - general: Changed the interface to TFormula such that now everything
1308 is parsed by TFormula, which should allow to use phrases even
1309 without paranthesis correctly parsed.
1310
1311 - callisto: replaced the AdHoc number of effective integration slices
1312 in the digital filter by an average of the correct number, averaged
1313 over all possible set of weights. This also gives correct numbers
1314 for the lo-gains which were totally wrong before.
1315
1316 - callisto: drastically reduced memory consumption by not storing
1317 all intermediate calibration results in memory anymore (we might
1318 write them into a file in the future)
1319
1320 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1321 debug plot displayed as a standard plot) use the context menu
1322 somewhere between the two upper plots, click on "DrawNicePlot"
1323 and enjoy the result. (It is the same context menu which contains
1324 the "DrawAll" option)
1325 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1326
1327
1328
1329 *** Version 0.10.2 (2006/10/15)
1330
1331 - general: changed the building of the sequence files such, that
1332 the source-/project name in case of wobble-sources is not the
1333 source/project of the first data run anymore but the new generalized
1334 wobble source/project
1335
1336 - general: Added some functions to MAstro to calculate sun and
1337 moon properties
1338
1339 - general: Added two new macros (starvisday.C and starvisyear.C)
1340 which allow to plot the visibility of several stars in one day
1341 or of one star along one year
1342
1343
1344
1345 *** Version 0.10.1 (2006/10/11)
1346
1347 - general: HTML logging output was distorted... fixed.
1348
1349 - general: Changed the writing of the sequencefiles such that only
1350 as many pedestal files as giving at least 1000 pedestal events which
1351 are nearby the first calibration run are used as pedestal runs
1352
1353 - sponde: In the calculation of the collection area(s) and the
1354 distribution for MOnte Carlo and estimated energy the error
1355 calculation was wrong because root didn't take the errors
1356 properly into account... fixed.
1357
1358
1359
1360 *** Version 0.10 (2006/10/10)
1361
1362 - general: all executables now check consistency of the root version
1363 installed with the root version used for compilation. The return
1364 code in this case is 255.
1365
1366 - general: The algorithm to build seqeunces has been redesigned
1367 completly. It is now more flexible in terms of a resource file
1368 resources/sequences.rc which can be used to partly overwrite
1369 the default algorithm and defined the important part of the
1370 algorithm. It also takes correctly into account several ways
1371 of taking wobble-data. Currently the new algorithm doesn't take
1372 the number of pedestal events anymore into account (so a sequence
1373 could have much less than 1000 pedestal events and data runs are
1374 no-more used instead)
1375
1376 - general: a lot of small changes to make the code compatible with
1377 root 5.12/00 and gcc 4.1
1378
1379 - general: Fixed some warnings thrown if more warnings are switched
1380 on in the compiler
1381
1382 - general: Added a function to MMath which returns the Median of
1383 the distribution abs(y[i]-median) but at 68:32 division instead
1384 of 50:50, which is somehow the median counterpart of the rms.
1385
1386 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1387 even if they are compressed with gzip (recommended compression
1388 is with "-1")
1389
1390 - showplot:
1391 + batch mode creation of image files now works with root 5.12/00
1392 + added support for writing bmp (though it never produces
1393 bmp which can be read by programs like xv or gimp)
1394 + added support for xml
1395 + added new option to start the display with a different size, by
1396 --display-width=nnn or --display-height=nnn
1397 + added options to define the canvas size when the display is started
1398 --canvas-width=nnn or --canvas-height=nnn
1399 the option can also be used for batch-mode conversion
1400 + added an option which automatically fits the display size to the
1401 desktop-size: --auto-size
1402
1403 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1404
1405 - merpp: allow the reports to have 1000ms due to a bug in the camera
1406 program.
1407
1408 - callisto: New swapped pixels have been found and corrected. For
1409 details see MRawRunHeader::FixAssignment()
1410
1411 - callisto: Callisto now raises an error if one of the input files could
1412 not be opened.
1413
1414 - callisto: In some rare cases it could happen that in the signal
1415 extraction of the digital filter the extractor returned nonsense
1416 results due a wrong initializion of a variable (this happens in
1417 cases in which the extracted signal is exactly zero or the
1418 digital filter couldn't slide because of a too small extraction
1419 window, which could happen in the lo-gain extraction)
1420
1421 - callisto: The lo-gains have been marked as valid in some cases
1422 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1423 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1424 smaller than the number of slices (fLoGainWindowSize) needed
1425 by the lo-gain extractor
1426
1427 - callisto: Updated absolute calibration constants (muon calibration)
1428
1429 - callisto: fixed a bug which caused the hi-gain saturation not
1430 to be handled properly in the spline (the position of the
1431 saturation was calculated incorrectly)
1432
1433 - callisto: fixed a bug which gave weird results if hi- _and_
1434 lo-gain could not be extracted properly. In some cases hi-
1435 and lo-gain have not been extracted at all and the random result
1436 got calibrated. In other cases the hi-gain was saturating and the
1437 lo-gain has not been extracted. For this a completly arbitraty
1438 scale factor was applied to the result from extracting the
1439 charge of the saturating hi-gain.
1440
1441 - callisto: improves handling of extracted signal if lo- and/or
1442 hi-gain could not be extracted properly. If no appropriate
1443 calibration of either the signal or the arrival time is possible
1444 the pixel is now markes as unsuitable instead of estimated.
1445
1446 - callisto: Fixed a problem in the spline extraction which gave
1447 weird results if the signal was extracted from the first (and
1448 highest) slice (as a workaround extraction from the first
1449 slice has been forbidden)
1450
1451 - callisto: Fixed a bug regarding the use of the QE which doesn't
1452 effect the result because the default is used anyhow.
1453 (The bug was there since 14/07/2005)
1454
1455 - callisto: Changed the default for fgLoGainStartShift to -2.4
1456
1457 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1458 factors to be always 10 for all pixels as soon as the first
1459 calibration update has happend.
1460
1461 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1462 was off by more than one slice (which gives wrong values for
1463 pixels which have saturated the hi-gain) This was a problem
1464 mainly for timing studies, not so much for the automatic standard
1465 analysis. Also the values for the Spline have been changed slightly:
1466 + Digital Filter from 1.70 to 0.95
1467 + Spline from 1.39 to 1.30
1468 The numbers were sorted out by an extensive test in the
1469 test-database.
1470
1471 - callisto: Removed the tab showing the average calibrated arrival
1472 time. It never gave useful information.
1473
1474 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1475 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1476 and both were extracted because the hi-gain was above the
1477 LoGainSwitch.
1478
1479 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1480 lo-gain pulse position (after application of LoGainOffset, which
1481 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1482 have saturated and both were extracted because the hi-gain was above
1483 the LoGainSwitch.
1484
1485 - callisto: After extensive tests a new threshold level for determination
1486 of the pulse position has been found at 50phe. This is due to the
1487 fact that for lower pulses the arrival time changes its average
1488 behaviour dramatically. It tends to the average of the extraction
1489 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1490
1491 - callisto: Added two more plots to the calibration part. The average
1492 extracted signal and the average extracted arrival time as
1493 extracted by the signal extractor (This can help debugging problems
1494 because it doesn't involve a fit)
1495
1496 - star: changed the fit for the effective on time such that initial
1497 values are calculated automatically now instead of using build
1498 in values. This makes the fit more indepedant of the underlaying
1499 rates. With a test of ~350 sequences in the test database it could
1500 be shown that the new fit gives the same result +/-1sek.
1501 The highest deviation was +5s the lowest -10s. You can now control
1502 the bahaviour with two resource values:
1503 MHEffectiveOnTime.FistBin: 3
1504 MHEffectiveOnTime.NumEvents: 12000
1505 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1506 from the resulting gamma candidates
1507
1508 - star: The Center histogram in MHHillas is now by default displayed
1509 with the colz draw-option
1510
1511 - ganymed: now produces valid error codes if failed
1512
1513 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1514 with the option "hadronness" instead of "area" or "both" if
1515 you want to use both cuts. The hadronness cut includes a fixed
1516 cut in hadronness (index 8) and a fixed cut in size (index 9).
1517
1518 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1519 the M3Long of the anti source to be not properly evaluated
1520 (actually is was evaluated as a unique random number) in case
1521 of optimization with anti-theta cut switched on. This might have
1522 lead to improper, but not necessarily wrong, optimization results.
1523
1524 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1525 how to use random forest
1526
1527 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1528 ganymed_onoff.rc. Seems to be unintentional that they were different.
1529
1530 - sponde: Since the introduction of the possibility to define a
1531 normalization energy instead of using the integral the default
1532 was not using the integral anymore but a normalization energy of
1533 1GeV. It is now the integral again.
1534
1535 - sponde: Fixed a problem in the weighting which did not allow
1536 a MC slope of -1.
1537
1538
1539
1540 *** Version 0.9.6 (2006/05/24)
1541
1542 - general: changed the binning of the azimuthal profile of the camera
1543 such that it is aligned with the 60deg boundaries.
1544
1545 - merpp: better handling of problems with the TH, TD part of the
1546 CC-REPORT for files older than 200507190 and 200412210
1547 respectively
1548
1549 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1550
1551 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1552
1553 - callisto: if an arrival time is extracted outside the fadc range is
1554 was set to the boundary before. Now a random number is assigned
1555 instead to avoid unfortunate coincidences of arrival times just
1556 by this arbitrary value.
1557
1558 - callisto: added a new option to callisto.rc which allows
1559 to set the maximum arrival time difference allowed for the
1560 badpixel algorithm to determin whether a pixels belongs to a shower:
1561 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1562
1563 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1564 to 0.9 as suggested by Stefan due to a recent study on the fraction
1565 of pixels surviving the image cleaning
1566
1567 - callisto: switched off error in case of "pulse is too much to the left"
1568
1569 - callisto: The extraction window is not adapted anymore. This means that
1570 the pulse is extracted from the full range. The draw-back is that the
1571 background (pedestal) will become slightly higher. Switching on/off
1572 the PulsePosCheck in the callisto.rc only effects filling the
1573 histograms.
1574 WARNING: If the pulse is too much to the left data is calibrated!
1575 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1576 in the database to make sure that your data is valid!
1577
1578 - star: Show also the number of stars correlated correctly by the
1579 starguider
1580
1581 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1582 than one off-source region in wobble-mode. To use it add the following to
1583 your ganymed_wobble.rc:
1584 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1585 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1586 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1587 + Cut1.ThetaCut: None
1588 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1589
1590 - ganymed: in the case the latest report is older than a default (currently
1591 one minute) and the current report will be skip the starguider
1592 correction and calibration will be reset. The maximum age can be
1593 setup from ganymed.rc by (minutes):
1594 MPointingDevCalc.MaxAge: 1.5
1595
1596 - ganymed: A first implementation showing all size-bins for the theta-sq
1597 resp. alpha-plots in a single tab automatically
1598
1599
1600
1601 *** Version 0.9.5.1 (2006/05/05)
1602
1603 - general: Added a new option "zdiff" to the Makefile which runs
1604 "cvs diff" as "make diff" would do, but with compression
1605
1606 - general: accelerated MTFillMatrix (used for eample in all training
1607 and optimization macros) by skipping some obsolete calles in the
1608 eventloop the first and second loop could be accelerated by ~20%
1609
1610 - general: Added a missing feature in the MFilterList class which
1611 prevented MFEnergySlope from working correctly in trainenergy.C
1612
1613 - general: Accelerated the random forest training and usage a bit
1614
1615 - merpp: Adapted to new raw data file format version 6
1616
1617 - merpp: fixed a problem with reading the starguider reports
1618 after 6.3.2006
1619
1620 - callisto: At some times six pixels had to be exchanged manually in the
1621 data. If the pixels to be swaped are both not found, an error was raised
1622 and calibration was stopped. Now it is assumed they are intentially not
1623 mapped and the Error has been changed to a Warning.
1624
1625 - star: Added new image cleaning based on the arrival time of the shower.
1626 The new cleaning can be accessed using the parameter "Time" instead of
1627 the the old one (like "Absolute) in the star.rc-file.
1628 Recommended parameters:
1629 + MImgCleanStd.CleanLevel1: 8.2
1630 + MImgCleanStd.CleanLevel2: 5
1631 + MImgCleanStd.CleanRings: 2
1632 + MImgCleanStd.KeepSinglePixels: No
1633
1634 - star: Simplified the calculation of the effective on time. By letting
1635 the fit start in the third bin the result should become more stable.
1636 The fit quality is now ignored for the theta-plot which is not used
1637 in the analysis later. Still better pre-cut which, for example,
1638 remove events triggered by car-light (rate changing on a short
1639 time-scale) are missing.
1640
1641 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1642 for optimization (kWeakSource) which is suggested by the Berlin
1643 people for weak sources.
1644
1645 - macros: plotdb.C:
1646 + if no dataset and no time-interval is given only sequences with
1647 an effective on-time above five minutes are plotted anymore
1648 + added a new tab "RelTime" displaying the relative on-time
1649 (effective on-time divided by the observation time)
1650
1651 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1652 the optimization became a lot faster
1653
1654 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1655 To display them just delete the pads displayed on top.
1656
1657 - ganymed: fixed a bug which could cause strange behaviour in wobble
1658 mode if no starguider information was available due to an incorrect
1659 initialization of the starguider calibration
1660
1661 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1662 be changed from within the plot. It can also be setup from the
1663 resource file using:
1664 + MHDisp.fScaleMin: 0.325
1665 + MHDisp.fScaleMax: 0.475
1666
1667 - ganymed, showplot: Fixed a problem with the fit to the off-data
1668 (HistOff) which could cause a time lag or an inifinite loop.
1669 The bug did not effect the results at all.
1670
1671 - sponde: Added a new tab showing the effective collection area after
1672 trigger (including the software trigger)
1673
1674 - sponde: MMcSpectrumWeight has a new option which allows to define
1675 the scaling factor not by the integral of the events but at
1676 a defined energy:
1677 e.g. MMcSpectrumWeight.NormEnergy: 200
1678
1679 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1680 eventloops the loop could be accelerated by ~20%
1681
1682
1683
1684 *** Version 0.9.5 (2006/03/13)
1685
1686 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1687 and added the standard Disp-parametrization
1688
1689 - macros: added a new macro datacenter/macros/plotstat.C allowing
1690 to plot statistics about the data processing
1691
1692 - macros: added a new macro to plot the muon correction coefficients
1693 versus period (macros/plot/mucal.C)
1694
1695 - showplot: path inflation for ganymed files was broken
1696
1697 - callisto: Fixed an important bug. When the number of saturating pixels
1698 were calculated the bad pixel information already available from the
1699 calibration was ignored. This yields wrong values in case pixels
1700 are broken and saturate all the time or randomly.
1701
1702 - callisto: Updated Muon calibration constants. Spline data now also uses
1703 different values for different periods
1704
1705 - star: The time-evolution shown in the effective on-time plot now displays
1706 the axis range (if there are no holes it should be similar to the
1707 effective on-time)
1708
1709 - star: Added two new image parameters:
1710 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1711 the three pixels next to the center of gravity and the size
1712 + MNewImagePar.fConcCore: The ratio of the signals of all
1713 pixels inside or touching the ellipse and the size
1714
1715 - ganymed: now stops in requested source isn't found in catalog file
1716
1717 - ganymed: Many improvements to the phi-plot in wobble mode:
1718 + with a template the ideal background is displayed
1719 + a possible camera inhomogeneity is taken into account
1720 + the anti theta cut is better supported
1721 + the phi cut is automatically calculated from the theta cut
1722 See the examples in ganymed_wobble.rc for more details.
1723
1724 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1725 times the bin-width instead of the absolute energy
1726
1727 - ganymed: New cuts for on/off and wobble mode
1728
1729 - ganymed: The smearing of the False Source plot has been increased
1730 to 0.06
1731
1732 - ganymed: The starguider calibration can now be changed from the
1733 resource file.
1734 See the examples in ganymed*.rc for more details.
1735
1736 - ganymed: added a new option for on-/off-observations
1737 MJCut.RandomSourcePosition
1738 If switched on the distribution of observation time of the source
1739 position in the camera is calculated from the on-data and randomly
1740 applied with this distrbution to the off-data.
1741
1742 - ganymed: by skipping some obsolete calles in the eventloop the
1743 first and second loop could be accelerated by ~20%
1744
1745 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1746 position in the off-data randomly according to its distribution in the
1747 on-data.
1748
1749
1750
1751 *** Version 0.9.4.3 (2006/02/13)
1752
1753 - general: Fixed a bug in most of the programs which prevented the
1754 compile date in the startup message to be displayed
1755
1756 - general: Simplified program calls. The following abbreviations
1757 are now possible:
1758 showlog callisto 55599
1759 showplot signal 55599
1760 star 55599
1761 callisto 55999
1762 ganymed 2
1763 In this cases the corrsponding root-, log-, sequence- or dataset-
1764 filename is automatically compiled using the default datacenter
1765 paths ("/magic/*")
1766
1767 - general: Fixed a long outstanding bug which made axis tick marks
1768 disappear if MDataFormula was used (eg. abs(x))
1769
1770 - general: Updated MMath with new functions to calculate the results of
1771 a exponential, logarithmic and powerlaw fits analytically.
1772
1773 - general: Updated some macros with comments:
1774 + macros/optim/optimdisp.C
1775 + macros/optim/optimenergy.C
1776 + macros/optim/optimwobble.C:
1777
1778 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1779 files) now allows adding a pre-cut like in the optimization. E.g. this
1780 is useful to perform g/h-separation cuts before training the random
1781 forest.
1782
1783 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1784 correctly assigned in the raw data assignement table. A fix to correct
1785 the assignment tabel have been implemented.
1786
1787 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1788 by 90, 180 and 270 deg.
1789
1790 - general: the macro plotdb.C now allows to highlight sequences belonging
1791 to a datset. For more details see the descritions in the macro.
1792
1793 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1794 of the display, it gave wrong results espacially for big sizes.
1795 Now the embedded canvas should always have a ratio width/height=3/2.
1796 The "Size" options have been updated with values fitting the 3/2
1797 size ratio.
1798
1799 - RanForest:
1800 + Updated the random forest classes to support also the
1801 regression method implemented by Thomas H.
1802 + added new tutorial macro how to train the random forest
1803 for energy estimation (macros/optim/rfenergyest.C)
1804 + new classes to train the random forest (still in development)
1805 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1806 + new tutorial macros for random forest training in macros/train
1807 trainenergy.C, traindisp.C, trainseparation.C
1808
1809 - mars: now allows to setup a cut in the resource file mars.rc to choose
1810 the events to be displayed, eg:
1811 Cut.Condition: {0} && {1}
1812 Cut.0: MHillas.fSize>100
1813 Cut.1: MHillas.fSize<900
1814
1815 - merpp: Made aware of the new .rep format 200510250. This includes
1816 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1817 the discriminator thresholds (MCameraTD) and the disciminator
1818 delays (MCameraTD). All of them come with the CC report and are therefor
1819 written to the CC tree.
1820
1821 - callisto: fixed a bug in the calculation of the arrival times in
1822 the Digital Filter. They were all shifted by the same amount
1823 fHiGainFirst. This caused an offset in the order of the position of
1824 the left border of the extraction window in the times calculated
1825 from high-gain and from low-gain. The bug effected only the absolute
1826 arrival times. The bug was there since 30.1.2005.
1827
1828 - callisto: Changed the ExtractionWindow for the pulse position check
1829 such that the camera inhomogeneity becomes as less as possible and
1830 comparable to the pulso position check switched off. More details
1831 on the study will be given at our result web-page.
1832
1833 - ganymed: ganymed.rc, ganymed_onoff.rc:
1834 changed to new cuts trained with 1ES1218 and Crab-data
1835 for maximum sigma*log10(excess)
1836
1837 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1838 a new option was implemented to estimate Disp (CalcDisp)
1839
1840 - ganymed: Implemented two new options which allow
1841 to overwrite the default path to search for the sequence files
1842 --ins=/magic/sequences
1843 and where to search for the image data
1844 --ind=/magic/data/star
1845
1846 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1847 dx/dy from the resource file by
1848 MSrcPosCorrect.Dx
1849 MSrcPosCorrect.Dy
1850
1851 - ganymed: fixed reading the source catalog. Only as many chars
1852 as the requested source name had were compared (If a source
1853 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1854 were requested it could happen that the coordinates of
1855 "1ES1218" were read) The source coordinates are now printed
1856 in addition to its name to the logging output.
1857
1858 - ganymed: changed the background fit in the case of a ThetaSq function
1859 from a polynomial to a exponential, this should give a big improvement
1860 for on-only analysis'
1861
1862 - ganymed/sponde: Calculation of the error of single size-/energy-
1863 bins now uses Li/Ma (5) instead of LiMa (17)
1864
1865 - sponde: Added a plot E^2*dN/dE
1866
1867 - sponde: The energy estimator plot should now show values like
1868 they are commonly used.
1869
1870 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1871 (a powerlaw with cutoff didn't work before)
1872
1873
1874
1875 *** Version 0.9.4.2 (2005/10/01)
1876
1877 - general: added new tutorial macro macros/tutorials/threshold.C:
1878 how to calculate the threshold
1879
1880 - general: added a new game. Start it from the interpreter with
1881 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1882 and MagicReversi)
1883
1884 - general: neighbor pixels in MGeoms are now sorted clockwise
1885
1886 - merpp: made aware of new format 20050829-0
1887
1888 - callisto: New scale factors from muon analysis, stored in new
1889 resource file resources/calibration.rc
1890
1891 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1892 the eventloop if something went wrong. This is necessary for the
1893 automatic processing
1894
1895 - callisto: Implemented a new treatment for the time information
1896 developed by S.Ruegamer, this should give much better response than
1897 the old very primitive algorithm. This is especially important
1898 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1899 treatment was buggy! As neighbor pixels to interpolate the
1900 arrival times always the pixels 0 to 5 were taken)
1901
1902 - callisto: In addition to the new treatment of arrival times the
1903 decision of the treatment whether a pixel contains shower
1904 information or not is used to improve the signal interpolation
1905 further. Previously interpolated pixels showed a non-zero signal
1906 do the peak searching signal extractors. Having a signal pixel
1907 beside raised the signal above the cleaning level. Thus the
1908 pixel survived cleaning to often but with a too low mean signal.
1909 By replacing empty pixels with a gaus (mean and rms from the
1910 corresponding Area entries in MPedPhotCam) this effect can
1911 be supressed.
1912
1913 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1914 got lost when the events were stored by the calibration... fixed.
1915 (This was no problem for normal image cleaning because the pixel
1916 content was artificially set to 0 not surviving standard cleaning
1917 algorithm)
1918
1919 - callisto: Fixed a bug which caused the random and peak-search pedestal
1920 extracted with an extractor to be exchanged for the first (roughly)
1921 500 events (*Extractor and *ExtractorRndm).
1922 (They were simply exchanged in callisto.cc) This bug might have been
1923 introduced in Mars 0.9.4 when the order of calculation of the two
1924 types of pedestal in callisto got exchanged. The bug only effects
1925 the first seconds of data of each sequence.
1926
1927 - star: Taking the arrival time of Muons into account the calculation
1928 of the parameters could be made independant of the noise
1929 (pedestal rms). The dependance was due to the bias of the peak search
1930 extractor. Now only a ZA dependamcy is left which is not yet fully
1931 understood.
1932
1933 - ganymed: The sequences were still not sorted correctly in any case,
1934 because they were sorted by the full qualified path name. Now they
1935 are sorted by their sequence number.
1936
1937 - ganymed: new values for the spark-event-cut
1938
1939 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1940
1941
1942
1943 *** Version 0.9.4.1 (2005/08/18)
1944
1945 - callisto: fixed some problems with the calibration in case of
1946 inteleaved events. Therefor the final and some intermediate
1947 fits are skipped which would take place on partly filled #
1948 histograms and gave wrong results or failed completely.
1949
1950 - callisto: If the intermediate finalization of the histograms
1951 calculating the mean charge of the calibration signal fails
1952 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1953
1954 - ganymed: Fixed some bugs which caused problems in On-only mode.
1955 Still the false source plot doesn't give reasonable results.
1956
1957
1958
1959 *** Version 0.9.4 (2005/08/05)
1960
1961 - general: Fixed the ZA binning. It did not correctly fit the
1962 MC binning
1963
1964 - general: Added a class to correct for the missfocussing in
1965 April (MSrcPosCorrect)
1966
1967 - general: Random Forest energy estimator should now work properly
1968
1969 - general: MHCamera now displays the profiles in deg instead of mm
1970
1971 - general: MH::SetPalette offers a lot of new palettes
1972
1973 - general: MHillas - the case of CorrXY==0 is now handled properly
1974
1975 - general: implemented the possibility to change the line and
1976 marker style of a sky-grid drawn by MAstroCatalog
1977
1978 - general: Runs in sequences and datasets are now automatically
1979 ordered (it is assumed that the order of their filenames correctly
1980 represents the order of observations) to ensure correct reading
1981 of the subsystem data
1982
1983 - general: Runs cannot be added to a sequence twice anymore. Also
1984 Sequences cannot be added twice anymore to a dataset.
1985
1986 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1987 It gave wrong results by 1./2pi
1988
1989 - showplot: got a new option to start a root interpreter, too
1990
1991 - mars: now displays a rough estimate of Disp and the third moment
1992
1993 - mars: now displays the event time MTime if available
1994
1995 - mars: show muon parameters graphically
1996
1997 - mars: now the file to open can be given as commandline
1998 argument
1999
2000 - merpp: Added support for new arehucas version >= 200507190
2001 implementing values for three temperature sensors in the
2002 counting house (MCameraAUX) and the name of the HV settings file
2003 (MCameraHV).
2004
2005 - merrp: Also fixed some problems with wrong versions numbers stated
2006 by arehucas and implemented some fixed for old versions (<200407070)
2007
2008 - callisto: MCalibrationHiLoCam can now be printed from its context
2009 menu, eg in the TBrowser
2010
2011 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2012 - 1.39 (MExtractTimeAndChargeSpline)
2013 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2014 This is important mainly for timing studies.
2015
2016 - callisto: Changed limits in MHCalibrationChargeCalc from
2017 - -100.125 to -98 (fgChargeHiGainFirst)
2018 - 1899.875 to 1902. (fgChargeHiGainLast)
2019 - -100.25 to -99 (fgChargeLoGainFirst)
2020 - 899.75 to 901. (fgChargeLoGainLast)
2021 Introduced new limits:
2022 - fgNumLoGainBlackoutLimit: 0.05
2023 - fgLoGainBlackoutLimit: 3.5
2024 - fgLoGainPickupLimit: 3.5
2025
2026 - callisto: The handling of automatic weights for the digital filter
2027 has been improved. There are now new calibration weights special
2028 for Monte Carlo calibrations.
2029
2030 - callisto: Updated Muon scale with latest results (1% difference
2031 for most data, 5% for Mar/Apr'05)
2032
2033 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2034 was saturated and the blackout-events in the low-gain exceed the
2035 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2036 This excludes those pixels which have a saturating high-gain
2037 channel, but the low-gain switch does not switch often enough
2038 to make the distribution reliable.
2039
2040 - callisto: fix a bug counting the number of saturated events. Up to now,
2041 the number of saturated slices was counted (which is one for a not too
2042 high number), but for some (pathological) pixels, many more slices
2043 saturated and produced wrong limits.
2044
2045 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2046 + MCalibrationRelTimeCam.CheckFitResults: Yes
2047 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2048 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2049 + MCalibrationRelTimeCam.CheckOscillations: Yes
2050
2051 - callisto: introduce max. number of events for intercalibration,
2052 the rest gets skipped. Default: 4096
2053 The calibration causes too many un-reliable pixels if more
2054 than about 5000 events are treated (@500 Hz) because of the
2055 mode hopping of the VCSels. However, in the past, some
2056 calibration runs have been taken (erroneously) with more
2057 than 5000 events, especially the intensity scans where
2058 a good precision is needed.
2059
2060 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2061 photo-electrons for the spline extractor by 1-2% (correctly).
2062
2063 - callisto: The intercalibration is now done using a full f-factor
2064 method instead of a simple update. This makes things slower but
2065 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2066 changes.
2067
2068 - callisto: MPedestalY3 now uses the same extraction range as the data
2069 as calculated by MPedestalY2
2070
2071 - callisto: A check of the fraction of allowed unsuitable (10%) and
2072 unreliable (30%) pixels has been addded when the conversion is
2073 calculated from interleaved events
2074
2075 - star: fixed a bug which caused MEffectiveOnTime containers not to
2076 be written. In the worst case they were skipped almost all, in the
2077 best case they were all ok. It depends on how often the new value
2078 was assigned just with an event which was skipped later by another
2079 task
2080
2081 - star: new histograms MHPointing and MHRate
2082
2083 - star: New tab (Currents) displaying the time evolution of the mean
2084 DC currents
2085
2086 - star: New tab (MeanRms) displaying the time volution of the mean
2087 Pedestal Rms
2088
2089 - star: Output now contains MReportStarguider
2090
2091 - star: Improved muon analysis. Due to the absense of a constant
2092 for the gaus fit for arc width and the fact that the arcwidth
2093 plot was a histogram instead of a profile the resulting psf
2094 became pedestal rms dependant
2095
2096 - ganymed: added new plot (MHPhi) for wobble mode as described in
2097 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2098
2099 - ganymed: corrects now (correctly?) for the misspointing in
2100 May/April 05
2101
2102 - ganymed: Two new default templates for ganymed.rc are avilable:
2103 ganymed_onoff.rc and ganymed_wobble.rc
2104
2105 - ganymed: The first version of MFMagicCuts has been released
2106
2107 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2108
2109 - ganymed, sponde: There are two new options to determin the number
2110 of bins for the signal region (NumBinsSignal) and the number of
2111 total bins (NumBinsTotal) in the MHThetaSq histogram
2112
2113 - ganymed: optimized palettes for MHDisp
2114
2115 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2116 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2117 sqrt(2) to large
2118
2119 - ganymed: The false source plot (MHDisp) is now based on Disp
2120 and a background model determined in the first loop is
2121 subtracted
2122
2123 - ganymed: MFMagicCuts are now available in the cvs. The correct
2124 solution for the disp ambiguity problem is now calculated using
2125 the third moment. The third moment cut therefor is skipped.
2126
2127 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2128 already determined by the third moment along the major axis and
2129 so its actual sign is aligned along the major axis of the shower.
2130
2131 - ganymed: If starguider data is available it is taken into account
2132 when calculating the source position. This is especially important
2133 for wobble data at high zenith angles and culmination data.
2134
2135 - ganymed: If available the starguider data is taken into account as
2136 good as it is possible without a starguider calibration. To switch
2137 it off add
2138 MPointingDevCalc.MaxAbsDev: -1
2139 to your ganymed.rc
2140
2141 - sponde: the zenith angle distribution is now weighted instead of
2142 choosen by default. This gurantees higher statistics in the highest
2143 and lowest energy bins. To switch this behaviour off use...
2144
2145 - sponde: now automatically displays the energy threshold
2146
2147
2148
2149 *** Version 0.9.3 (2005/06/03)
2150
2151 - general: MMcEvt now derived from MMcEvtBasic which should
2152 have no influence on compatibility with older camera files
2153
2154 - general: Implemented a new option to MReadReports which allows
2155 to force reading of the first event of some trees (eg. Drive-tree)
2156 before any other tree.
2157
2158 - general: Made a fix to MPointingPosCalc which assumes that the
2159 run-type is real-data if Process is called before ReInit, such
2160 that also the very first Drive-events in a run are treated
2161 correctly.
2162
2163 - shoplot now displays the filename in the title bar of the window
2164
2165 - merpp: new options: --auto-time-start --auto-time-stop which
2166 allow to cut updating with slow-control at the start- or
2167 (previousle --auto-time only allowed: and) stop-time of
2168 the run stored in the runheader.
2169
2170 - callisto: changed default of fgFallTimeHiGain in
2171 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2172 already set as default in callisto_Dec04Jan05.rc
2173
2174 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2175 now changes the filename for new weights automatically for
2176 cosmics, MC and for different calibration colors.
2177
2178 - callisto: a problem with the order of some code cause the
2179 name of the weights file in MPedestalY2 to be ignored.
2180 Wrongly the calibration_UV weights were used instead
2181 of the cosmics weights set in callisto.rc.
2182
2183 - callisto: should allow ct1 pulser data when the color is
2184 explicitly set also for pretty new runs
2185
2186 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2187 to introduce an additional scale factor (should be around 1)
2188 to adapt for slight deviations in different extractors from
2189 the MC calibration. For MC calibrations the scale factor
2190 is fixed to 1
2191
2192 - callisto: MFCosmics should handle very high signals a bit
2193 more accurate now
2194
2195 - callisto: when calculating the mean pedestal rms for different
2196 pixel sizes or sectors also kUnsuitableEvt is now taken into
2197 account - not only kUnsuitableRun
2198
2199 - callisto: '-raw' option is now the default
2200
2201 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2202 This has the advantage that mean values in the calibration (eg
2203 arrival times) are calculated more accuratly.
2204
2205 - callisto: In the resource file callisto_Dec04Jan05.rc
2206 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2207
2208 - callisto: new Hi-/Lo-Gain intercalibration constants
2209 hilocalib_sp1.root and hilocalib_sp1_mc.root
2210
2211 - callisto: changed default for MJPedestalY2.MaxEvents
2212 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2213
2214 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2215 has changed from 9.0 to 6.0. This is necessary to exclude two very
2216 ringing pixels in September which - when kept - destroy the image
2217 cleaning around them (Markus G.)
2218
2219 - callisto: (!) The Muon analysis of all data taken so far has
2220 suggested that different extractors give slightly different
2221 absolute results after calibration, due to there different
2222 handling of the calibration- and cosmics pulse shape. Although
2223 the over all calibration seems to be a bit to pesimistic (or
2224 the MC seems to be a little bit - 3-5% - too much attenuated).
2225 There for correction factors have been introduced which correct
2226 the calibration constants by
2227 0.956937799 for Digital Filter (callisto.rc)
2228 and
2229 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2230 calibration. The main advantage is, that both data types can
2231 be easily analysed together and compared to the same MC sample.
2232 The factors are choosen such, that the reference is now a
2233 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2234
2235 - star: fixed a bug which caused the first bin of the histograms
2236 vs time to disapear in PostProcess. This gave wrong results
2237 on the screen. The output and all following programs not
2238 directly accessing the histograms haven't been affected
2239
2240 - star, ganymed: Made sure that always the first Drive-tree event
2241 is read and Processed before the first data event was read.
2242
2243 - ganymed: implemented the possibility to replace the standard
2244 false source plot with a different one. For example: If
2245 you want to use a Disp based FS plot use the resource:
2246 NameHistFS: MHDisp
2247 For details about the requirements of these plots look
2248 at the corresponding classes
2249
2250 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2251 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2252 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2253 case MAlphaFitter is setup correctly. For On-Only optimization
2254 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2255 RunOn() instead of Run(). For energy estimation MJOptimize
2256 has been replaced by MJOptimizeEnergy
2257
2258 - sponde: The input MC spectrum can now be weighted to fake a
2259 different spectrum. This is done via MMcSpectrumWeight. For
2260 more details see the class description and sponde.rc
2261
2262 - sponde: The paremeter comparsion plots are not scaled by
2263 their entries anymore. Instead the MC plot is scaled by using
2264 the result spectrum of the analysis. If the input MC spectrum
2265 and the result spectrum has different slopes the absolut
2266 normalization is normally wrong.
2267
2268
2269
2270 *** Version 0.9.2 (2005/05/20)
2271
2272 - general: Changed the default paths for calibrated data and image
2273 files. (The implemented access to these files doesn't yet exist)
2274
2275 - general: support for MRunIter has been removed from the job classes
2276 (use the setter functions of MSeqeunce instead)
2277
2278 - general: ProcessFile has been renamed to Process in all job classes,
2279 because ProcessFile is missleading
2280
2281 - general: The storage of the palette in MHCamera is now possible
2282
2283 - general: new bits describing unsuitable and unreliable pixels have
2284 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2285 kDeadPedestalRms, kFluctuatingArrivalTimes
2286
2287 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2288 versions newer than V200404070
2289
2290 - general: support for cc file versions newer than V200504130. Added
2291 support for active loads (MCameraActiveLoad) and central pixel
2292 (MCameraCentralPixel)
2293
2294 - general: added new histograms for image parameters versus size
2295 (MHVsSize)
2296
2297 - general: The eventloop now automatically calls PrintStatistics
2298
2299 - Status Display: Improved support for printing:
2300 + A default can now be set in .rootrc (for more details see
2301 MStatusDisplay::PrintPS)
2302 + A print dialog is opened so that printer and command line
2303 can be canged
2304
2305 - showlog: improved such that it handles different verbosity levels
2306 more accurate now. This mean you can suppress output when
2307 using showlog.
2308
2309 - showplot: improved
2310 + The new graphics formats have been implemented
2311 (pdf, svg, png, jpg and xpm)
2312 + Implemented an interface for printing. Because you can change
2313 the printing command from the command line you can use all
2314 the nice postscript tool. To print a booklet for example call:
2315 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2316 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2317 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2318
2319 - callisto: fixed a bug in the recognition of the calibration bit
2320 pattern. Concerns only intensity calibration. (The strength of the
2321 intensity has been updated in some cases)
2322
2323 - callisto: add a filter against PIN Diode events when running over
2324 calibration runs since some of the recent calibration runs have
2325 been taken with Pin Diode.
2326
2327 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2328 39943, 44833 in the calibration (MCalibColorSet)
2329
2330 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2331 been set to 1e-18 in callisto_Dec04_Jan05.rc
2332
2333 - callisto: in callisto_Dec04Jan05.rc: set value for
2334 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2335 statistics for the calculation of the mean pulse time
2336 of the cosmisc
2337
2338 - callisto: the charge limit in the calibration has been raised
2339 from 2.5 to 4.5
2340
2341 - callisto: new setup read from callisto.rc
2342 + MCalibCalcFromPast.fNumEventsDump
2343 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2344 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2345
2346 - callisto: MExtractTimeAndChargeSpline extractor:
2347 + The integration ranges were shifted by 0.2 FADC slices to the right.
2348 + unreliable handling of floating point values caused different
2349 results on different platform or with different compiler options:
2350 The new algorithm is numerically exact and more accurate because
2351 it doesn't calculate the integration position by multiple times
2352 adding the step-size (which results in numerical uncertanties
2353 exspecially if multiplied with large numbers)
2354 + A lot of fixes have been introduced which effects integrating the
2355 spline at the edges of the valid range. In this case any memory
2356 was randomly accessed. This behaviour can be tested replacing
2357 all MArrayF by TArrayF which perform a range check (but of course
2358 they are a lot slower)
2359 ! No result obtained with the Spline before can be trusted! Due to
2360 random memory access it might by completely random!
2361
2362 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2363 + extraction range in the high gain to 4.
2364 + weights file to cosmics_weights46.dat
2365
2366 - callisto:
2367 + introduce the check for fluctuating arrival times.
2368 + set charge limit to from 2.5 to 4.5
2369 + introduce asymmetric exclusion due to "deviating number of phes":
2370 Default: -9.0 +4.5
2371 + make deviating number of phes unsuitable (see David's findings).
2372
2373 - callisto: fixed the display of unsuitable pixels. The old change
2374 to a real profile in MHCamera broke it.
2375
2376 - callisto: The cosmics filter is used in MJCalibration now
2377 independant of the pulser color (formaly it was used only for
2378 CT1-pulser data). The threshold of number of max empty pixels
2379 has been raised from 2% to 5% in MJCalibration. The maximum
2380 fraction of rejected event is 50% otherwise the calibration has
2381 failed. The filter now ignores unsuitable pixels.
2382 Setup the filter from callisto.rc using "ContCosmics"
2383 (see MFCosmics::ReadEnv)
2384
2385 - callisto: changed default for fgOffsetFromLogain back
2386 from -2.8 to -1.8 in digital filter.
2387
2388 - callisto: for the common extractors
2389 + MExtractFixedWindow
2390 * MExtractTimeAndChargeSlidingWindow
2391 * MExtractTimeAndChargeSpline
2392 * MExtractTimeAndChargeDigitalFilter
2393 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2394 and fResolutionPerPheLoGain
2395
2396 - callisto: Updated the hi-/lo-gain intercalibration constants
2397 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2398 hilocalib_df6.root
2399
2400 - callisto: The default lo-gain extraction window for the
2401 MExtractTimeAndChargeSlidingWindow extractor has been increased
2402 from 6 to 8 to take the stretch of the pusle into account
2403
2404 - callisto (!!!): fixed an important bug in the setting of the
2405 incoming pedestal pointer to the signal extractor extracting
2406 pedestals. This bug caused the pedestals not to be subtracted
2407 correctly in the calibration afterwards. The effect was about 10%
2408 too high conversion factors for the digital filter and the spline
2409 and more than 40% for the sliding window.
2410 The bug existed since end of February! (Markus G.)
2411
2412 - star: added muon support to star. A new tab "MHMuonPar" is
2413 displayed. The lower right plot is an estimate of the point spread
2414 function. A reference value is displayed. To get the real PSF
2415 you must compare with MC. The setup for the muon analysis
2416 is done in star.rc. More informations can be found in
2417 MHSingleMuon and MHCalibParCalc
2418
2419 - star: The weather data is now displayed in star
2420
2421 - star: MEventRateCalc handles the calculation of the event rate more
2422 accurate now in case of the start of a new run inside a sequence
2423
2424 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2425 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2426 changed only minimally
2427
2428 - ganymed: (MJCut and MJOptimize) now displayes the number of
2429 excess events versus size. The energy estimation is done in
2430 MJSpectrum (sponde)
2431
2432 - ganymed: got support for using other variables than Alpha, eg. Theta.
2433 Therefor you need a class deriving from MHAlpha which supports
2434 this variable (one is already existing: MHTheta, which is now the
2435 default in ganymed). It is setup through ganymed.rc
2436
2437 - added a full featured spectrum program (sponde) which reads
2438 ganymed output and monte carlos and compiles a spectrum
2439
2440
2441
2442 *** Version 0.9.1 (2005/04/14)
2443
2444 - Fix bug on the arrival time reconstruction when using Digital
2445 Filter (in some marginal cases (10%) times were reconstructed shifted
2446 by 0.2 slices)
2447
2448 - all executables now return 2 where in previous versions -1 has
2449 been returned (gave problems with shell-scripts)
2450
2451 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2452 also done with a intercalibration input file
2453
2454 - a bug in the time fine adjustment of the digital filter has been fixed
2455
2456 - a lot of small fixes to calling TPad::Divide with a margin==0
2457
2458 - MStatusDisplay now shows the memory usage
2459
2460 - added a memory leak statistic after the eventloop
2461
2462 - MHadronness replaced by MParameterD
2463
2464 - MEnergyEst replaced by MParameterD
2465
2466 - wobble mode can now be switched on from the data-set
2467
2468 - switched on bad pixel detection for a pedestal level
2469 which is more than 5 times the variance
2470
2471 - Fixed default paths to be correct for the new data center
2472
2473 - Fixed handling of drive data. The pointing position in now
2474 copied to MPointingPos inside star for real and MC events
2475
2476 - made sure, that the sequences in a dataset are sorted by
2477 their number to ensure the correct synchronization
2478
2479 - added all resource files necessary to handle spline extraction
2480 of signal for the late 2004 and the early 2005 data
2481
2482 - update the reference lines for the december data
2483
2484 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2485 This is important for the Dec. and Jan. data where the calibration
2486 pulse position changes much.
2487
2488 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2489 filter. This corrects only an defective extraction of the MC at
2490 low-gain signals lower than 90 phes.
2491
2492 - fixed some slowdown in calibrating data with interleaved events from
2493 Jan and Dec. As a workaround made the pretty palette the default.
2494 The inverse Deep Blue Sea has a bug which slows down long calibration
2495 runs a lot.
2496
2497 - implemented new values from new starguider report as defined
2498 in TDAS00-07 V7.1 (eg SkyBrighness)
2499
2500 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2501 in starguider report (If you merpp the same reports with this version
2502 you'll get the correct units (arcmin) but a different result
2503 than with old versions (wrong units))
2504
2505 - Now the status display can also write PNG, JPEG and XPM (other file
2506 formats are still unsupported by root)
2507
2508 - added a lot of scripts and macros in directory datacenter used
2509 for automatic processing
2510
2511
2512
2513 *** Version 0.9 (2005/03/23)
2514
2515 - Calibration is now done autmatically into photo-electrons like
2516 decided by the Collaboration Board
2517
2518 - Reference lines in the display can be read from resource file
2519
2520 - Interlaced calibration events can be handled by callisto
2521
2522 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2523 and applied in callisto.
2524
2525 - class MJCalibTest can be called by callisto
2526
2527 - callisto can now run with three data types: rawdata, rootdata, MC
2528
2529 - added two classes mreport/MReportStarguider.cc and
2530 mreport/MReportStarguider.h for implementing starguider-data
2531
2532 - the output of merpp-update now contains starguider information:
2533 MReportStarguider and MTimeStarguider
2534
2535 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2536 values were lower than they should. This was more visible for high
2537 energy (Size) events.
2538
2539 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2540
2541 - added a new loop to callisto to support the correct extraction of
2542 the pedestal and pedestal rms through the signal extractor
2543
2544 - added class to perform fourier tranformation of a hexagonal structure
2545 (MHexagonalFT)
2546
2547 - added class to perform fourier tranformation of a hexagonal structure
2548 in a tasklist (MHexagonalFTCalc) example: hft.C
2549
2550 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2551 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2552 small pixels, example: extendcam.C
2553
2554 - added possibility to write data to memory (TTree) using MWriteRootFile
2555
2556 - added possibility to read a TTree stored only in memory by MReadTree
2557
2558 - new classes to deal with the interleaved calibration events:
2559 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2560
2561 - implemented filters to callisto to skip calibration events
2562
2563 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2564 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2565 the slices by statistics
2566 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2567 signal extractor without randomization
2568 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2569 with the signal extractor with randomization (extraction window is
2570 randomly fixed)
2571 The three kind of pedestal is not yet implemented (for speed reasons) as
2572 long as nobody really needs it:
2573 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2574 extracted with the signal extractor with randomization
2575
2576 - callisto now finds the pulse position in the data automatically
2577
2578 - implemented data reduction in calibrated data by reducing the precision
2579 of the stored floating point values (pedestal, rms and signal) to
2580 roughly 0.5%
2581
2582 - fixed showplot to make file format conversion (eg. converting a
2583 status display stored in a root file into a postscript file) in
2584 batch mode possible:
2585 showplot -b --save-as-ps[=outfile.ps] infile.root
2586
2587 - Allow class names as part of filter rules, eg
2588 (MFSupercuts) && (MHillas.fSize>100)
2589
2590 - fixed a lot of stuff to allow all programs to process MonteCarlo
2591 camera files.
2592
2593 - enhanced possibility to debug reading of resource file
2594
2595 - MDataChain should handle priorities of operator more
2596 accurate now
2597
2598 - completely revised the container in which the signal is stored
2599 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2600 * the new implementation is faster and
2601 * needs less storage space
2602
2603 - FIRST version which can process Monte Carlos through the
2604 whole chain of programs (callisto, star, etc)
2605
2606 - implemented new image parameters for the border length of
2607 the shower image (MNewImagePar2)
2608
2609 - implemented wobble-mode in ganymed
2610
2611 - new class (MJOptimize) taking care of all optimization processes
2612
2613
2614
2615 *** Version 0.8.6 (2004/10/05)
2616
2617 - New combined signal and time extractor
2618 MExtractTimeAndChargeDigitalFilter
2619
2620 - The Report for the trigger section in the CC run summary has been
2621 updated, and now the IPRs (Individual Pixel Rates) are available.
2622
2623 - new macros for database interaction: filldotrun.C, filldotrbk.C
2624
2625 - added new program which can convert colored output which was redirected
2626 into a file back into colored text (for example to display it with
2627 more): showlog
2628
2629 - added new program to display an MStatusArray of plots (stored with
2630 MStatusDisplay) from a file: showplot
2631
2632 - Added support for Sequences (MSequence). Sequences are blocks of run
2633 files containing the same calibration and belonging to the same
2634 source
2635
2636 - Added a new task (MTaskEnv) which can be used in setup files to switch
2637 between different tasks (for example to choose a signal extractor)
2638
2639 - Implemented automatic file splitting in MWriteRootFile
2640
2641 - After image cleaning an island index is assigned to all used pixels.
2642 The index corresponds to the order of the islands in size.
2643
2644 - added a cleaning which takes signal height _and_ arrival time into
2645 account: probability cleaning (for more details see MImgCleanStd)
2646
2647 - added a cleaning which takes takes the absolute number of photons
2648 times the area ratio as cleaning level
2649 (for more details see MImgCleanStd)
2650
2651 - Changed calculation of image parameters such, that it can be done
2652 for all used pixels or the pixels with a defined island index only
2653
2654 - implemented new image parameters displaying the number of islands,
2655 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2656
2657 - event display in executable changed to support also calibrated files
2658 (done with MJCalibrateSignal)
2659
2660 - added program doing the calibration and the signal extraction
2661 and signal calibration: callisto Most part of the setup is done
2662 by a resource file: callisto.rc
2663
2664 - implemented support for pixels with negative IDs (Raw file format
2665 version 4)
2666
2667 - implemented an new option in merpp (--auto-time) to get the time
2668 range for cc and/or caco data from the run header of the raw data
2669
2670 - New star-program (star and MJStar). Taking calibrated data from
2671 callisto/MJCalibrateSignal as input. The setup is done through
2672 a resource file: star.rc
2673
2674 - Added possibility to setup the eventloop in the mars-executable
2675 Camera Display by a resource file: mars.rc
2676
2677 - The the mars-executable Camera Display can now also read
2678 calibrated data files written by callisto/MJCalibrateSignal
2679
2680 - Added a new class which can calculate the source position in
2681 the camera from a pointing model known to be correct and
2682 the pointing model used for observations (MSrcPosFromModel)
2683
2684 - added a new version of the class calculating the effective on-time
2685 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2686 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2687 MHTimeDiffTheta.
2688
2689 - added the possibility to count how often a signal is above (or
2690 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2691 can replace MHTriggerLvl0)
2692
2693 - added ore convinient ways to set the axis-titles of your histograms
2694 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2695 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2696
2697
2698
2699 *** Version 0.8.5 (2004/08/06)
2700
2701 - new Signal Extractors: MExtractFixedWindowSpline
2702 and MExtractAmplitudeSpline
2703
2704 - implementes interleave in merpp to be able to merpp parts of a file
2705
2706 - implemented force-functionality to merpp
2707
2708 - star display to display star catalogs (MAstroCatalog)
2709
2710 - star display to 'mirror' stars to the camera (MAstroCamera)
2711
2712 - implemented a new cleaning option which allows cleaning scaled with
2713 the real ratio of the rms depending on the pixel size, not only the
2714 square root of the pixelsize (MImgCleanStd, MCameraData)
2715
2716 - removed obsolete MBlind* classes
2717
2718 - Signal extractor taking the AB flag into account implemented (this makes
2719 an odd number of slices for signal extraction possible
2720 (MExtractSignalABcorr)
2721
2722 - implemented a class extracting the pedestal from the raw-data (events)
2723 itself using empty lo-gain (MpedCalcFromLoGain)
2724
2725 - Added mean values to MPedPhotCam
2726
2727 - Added Makefile for Darwin (this OS is NOT officially supported!)
2728
2729
2730
2731 *** Version 0.8.4 (2004/04/19)
2732
2733 - new fast arrival time extractor using cubic splines:
2734 MExtractTimeFastSpline
2735
2736 - implementes multi-argument support in MDataChain
2737 ("pow(a, b)")
2738
2739 - implemented double reference support in MDataChain
2740 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2741
2742 - added support in MF for expressiond like
2743 "MHillas.fWidth<2*<MHillas.fLength"
2744
2745 - MDataChain is now able to support variables like [0], [1], ...
2746 which can be used in fit functions as parameters. The interface
2747 is implemented through the new virtual function
2748 MParContainer::SetVariables
2749
2750 - added new class MArrivalTimeCam/MArrivalTimePix:
2751 Storage containers to hold the ArrivalTime of the camera/pixel
2752
2753 - added new classes for the calibration of relative arrival times:
2754 MCalibrationRelTimePix and MCalibrationRelTimeCam
2755
2756 - added new classes to extract the signal of the blind pixel and the
2757 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2758
2759 - added new classes for the bad-pixels treatment (MBadPixels*)
2760 which are more powerfull than the old ones (MBlindPixel*)
2761 and will replace them.
2762
2763 - added filter against cosmics: MFCosmics
2764
2765 - added new class MArrivalTimeCalc2:
2766 Calculates the arrival time as the signal weighted mean of the time
2767 slices in the maximum window
2768
2769 - added a new macro call pointspreadfucntion.C that fits with a 2D
2770 gaussian the DC spot for an star. It gives you the RMS of
2771 the PSF and the center of the star, very useful for misspointing
2772 studies.
2773
2774 - added support for multi-telescope camera files. Added classes
2775 MStereoCalc and MStereoPar, classes to calculate and store shower
2776 parameters calculated from the data of two telescopes, for the MC
2777 studies regarding the MAGIC clone.
2778
2779 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2780 MC data calibrated in photons instead of ADC counts.
2781
2782 - added three macros to show the calibration and analysis chain of
2783 MC data. The macro starmc.C does both calibration and analysis, producing
2784 an output containing Hillas parameters for each event. The macro
2785 mccalibrate.C does just the calibration and writes out a file containing
2786 pixel information in photons instead of FADC data. The macro starmc2.C
2787 reads in such a file and produces an output with Hillas parameters.
2788
2789 - added MPedPhotCalc to compute pedestals in units of photons, see
2790 macro pedphotcalc.C
2791
2792 - added all class to perform the calibration, see macro calibration.C
2793
2794 - added class MFFT to perform Fast Fourier Transforms
2795
2796 - added class MSimulatedAnnealing to perform simulated annealing
2797 minimizations
2798
2799 - added new macro bootcampstandardanalysis.C which holds the skeleton
2800 of the analysis chain discussed in the december bootcamp.
2801
2802 - added support for DAQ raw data file format V2
2803
2804 - implemented an arbitrary time stamp for the events from raw-data
2805 files with file version<3. It is calculated from the run number,
2806 the date of start and the FADC clock tick from the first module
2807
2808 - implemented the correct decoding of the event time-stamp
2809 coming from the DAQ for raw-data files with file-version>2
2810
2811 - added a new classes storing the pedestals in units of photons:
2812 MPedPhotPix, MPedPhotCam
2813
2814 - added support for DC current files from the camera control
2815
2816 - added support for start- and stop-time when merpping report files
2817
2818 - added MReportCC storing the weather data from the CC-REPORT
2819
2820 - added class to fill trainings and test matrices (MTFillMatrix)
2821
2822 - added a filter performing a software trigger (MFSoftwareTrigger)
2823
2824 - Added classes to perform parts of the standard analysis (Jobs):
2825 + MJPedestals
2826 + MJCalibration
2827 + MJExtractSignal
2828 Note: All of them are preliminary!
2829
2830 - Added Iterator to iterate over files giving only the run-number
2831
2832 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2833 the evolution of a sector vs time
2834
2835
2836
2837 *** Version 0.8.3 (2003/12/05)
2838
2839 - adapted Random Forest classes to allow the use with MC
2840 multi-telescope files which can be produced with the coming
2841 camera version 0.7.
2842
2843 - added classes to read and interprete central control report files
2844 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2845
2846 - enhanced merpp (the executable) to support .raw and .rep files.
2847
2848 - added classes for light calibration (MCalibration* and
2849 MHCalibration*) by Markus Gaug. Further work has to be and will
2850 be done soon.
2851
2852 - Added a preliminary 'synchronizer' (MReadReports) which will
2853 replace MReadMarsFile as soon as it is finished.
2854
2855 - Added a tutorial macro demonstrating how report files are merpped
2856 and how they can be read from the root file in the correct order
2857 of time (readrep.C)
2858
2859 - Added a generalized histogram (similar to MH3) called MVsTime
2860 which allows to plot variables (or rules - MDataChain - of
2861 variables) vs time. For an example have a look at tempvstime.C.
2862
2863 - Changed the name of the event trees:
2864 + Events --> Events
2865 + PedEvents --> Pedestals
2866 + CalEvents --> Calibration
2867
2868 - changed name of MTime in the event trees from MRawEvtTime to MTime
2869
2870 - added displaying the sector indices to the mars event display
2871
2872 - Magic Online Analysis (MOnA) implemented in a first version
2873 (see mona.cc, MOnlineDump and MOnlineDisplay)
2874
2875 - added classes to calculate event rate
2876 (preliminary: MEventRateCalc, MEventRate)
2877
2878 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2879
2880 - added classes dealing with the telescope pointing position (MPointing*)
2881
2882 - implemented the 'final' Mars time stamp based on some experiences with
2883 the new 'Synchonizer'
2884
2885
2886
2887 *** Version 0.8.2 (2003/11/10)
2888
2889 - accelerated standard analysis by a factor of 6-8 ...
2890 + doing precalculations in MGeomCam for the pixel area ratio
2891 + creating a look up table for the single pixels in MCerPhotEvt
2892
2893 - added task to calculates weights in case you want to 'change'
2894 the energy spectrum of a monte carlo file
2895 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2896
2897 - added a new executable star which implements the
2898 star.C macro as precompiled executable. Currently a flexible
2899 setup is not possible, but a 'input card' setup will follow.
2900
2901 - Starting to implement Multi-Telescope-Support based on the
2902 upcomming camera version 0.7. The base for a general support
2903 is implemented and the star-functionality is proven to work.
2904
2905 - Replaced Event-Display in and Camera-Display in the Mars GUI
2906 executable by a more convinient display base on MStatusDisplay.
2907
2908 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2909
2910
2911
2912 *** Version 0.8.1 (2003/10/20)
2913
2914 - added signal subtraction for pure on data by means of fitting
2915 the background in the off region or by performing a combined
2916 signal/background fit. Provides necessary histograms for
2917 obtaining energy spectra and a light curve.
2918
2919 - added classes to perform and study the selection of the
2920 2nd Level Trigger on MC data (example in triglvl2.C macro)
2921
2922 - added pedestal calculation
2923
2924 - implemented "democratic cleaning" (tail cut value proportional
2925 to pixel area) according to Wolfgang's suggestion.
2926
2927 - added Sigmabar treatment (calculation and basic histogramming)
2928
2929 - added basic routines to apply padding
2930
2931 - added first implementation of MARS-based source visibility plotter
2932 (needs to be linked against slalib, preliminary version)
2933
2934 - enhanced functionality of data chains: random numbers, conversion
2935 functions and access to MHMatrix objects
2936
2937 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2938 numbers under certain circumstances (runs with 0 events included)
2939
2940 - fixed a bug in the general filter MF (didn't work on some systems
2941 at all)
2942
2943 - fixed a bug in chaining files, which caused the analysis to crash or
2944 ignore files
2945
2946 - implemented more geometry classes describing the parameters used
2947 to simulate the PMT camera
2948
2949 - added new Monte Carlo classes containing the setup of the different
2950 programs in the MC chain.
2951
2952 - added a (preliminary) general task to evaluate chi-square of a given
2953 parameter in an eventloop.
2954
2955 - first implementation of a container describing the observatory
2956 location (Long, Lat, etc)
2957
2958 - added Random Forest - method for g/h-separation
2959
2960 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2961 (this means, that it is compiling, but not yet fully tested)
2962
2963 - added a new status display which can show the present status
2964 of histograms while an eventloop is running (MStatusDisplay,
2965 an example can be found at status.C)
2966
2967 - reorganized directories:
2968 classes describing the image --> mimage
2969 classes containing Monte Carlo Histograms --> mhistmc
2970 classes for Random Forest method --> mranforest
2971
2972 - added (event-)weights to fill histograms
2973
2974 - colors in logging output to screen
2975
2976 - changes to the Image Parameter declaration:
2977 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2978 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2979 + MHillasExt now derives from MParContainer instead of MHillas
2980 --> Files written with the old definition are more or less unreadable
2981
2982 - reading of reflector files
2983
2984 - display data from reflector files in the camera
2985
2986 - implemented currents (and display them in the camera)
2987
2988 - logarithmic scale in camera
2989
2990 - added class to iterate through directory contents (MDirIter)
2991
2992
2993
2994 *** Version 0.8 (2002/11/18)
2995
2996 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2997
2998 - corrected 48(!) wrong entries in the Next Neighbor table of the
2999 Magic Camera (all in the inner part of the outer ring, mostly
3000 missing a single NN)
3001
3002 - Fixed a bug in the table describing the Next Neighbours of the
3003 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3004 have any neighbour)
3005
3006 - changed trigrate.C: now it calculates the pure NSB triggers from
3007 a camera file (generated with no showers), so there is no need
3008 to introduce them by hand in the BgR array (for more details
3009 please ask Abelardo)
3010
3011 - added MHHadronness (and MHadronness) as a general facility to evaluate
3012 the quality of a gamma-hadron seperation method
3013
3014 - changed MWriteAsciiFile to accept rules (MDataChain)
3015
3016 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3017 must be replaced by calles to MWriteAsciiFile::AddColumn and
3018 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3019 changed.
3020
3021 - Implemented generalized event-matrices (one row per event)
3022 (MHMatrix)
3023
3024 - implemented the one dimensional composite probabilities
3025 (MHCompProb, MCompProbCalc, comprob.C)
3026
3027 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3028 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3029
3030 - Added a camera display displaying the pixel numbers to the
3031 event display gui.
3032
3033 - Added Monte Carlo Informations to event display gui
3034
3035 - Changed the camera display to display the pixel numbering
3036
3037 - Added three buttons to the camera display to change the palette
3038
3039 - Added the number of used and core pixels after image cleaning
3040 to MHillas
3041
3042 - Changed the algorithm used in MHillas according to TDAS 02-03
3043
3044 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3045
3046 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3047
3048 - Added fCosDeltaAlpha to MHillasSrc
3049
3050 - The numbers of photons used to calculate fConc and fConc1 in
3051 MHillasExt are now scaled with the pixel size, so that one get
3052 a four times smaller value for the bigger pixels in the outer ring.
3053
3054 - added new task to smooth the camera contents (MCameraSmooth)
3055
3056 - added possibility to use interpolated pixel values for blind pixels
3057 instead of removing it completely from the analysis
3058
3059 - Implemented the possibility to save the whole eventloop with
3060 its setup to a file. This information can be read and from
3061 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3062 and MEvtLoop::MakeMacro. If you find something not working, please
3063 report - this stuff is still in a beta phase.
3064
3065 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3066 file having crab starfield, but also for all following files - fixed
3067
3068 - MTaskList::PrintStatistics can now be instructud to print also the
3069 title, too: use PrintStatistics(0, kTRUE)
3070
3071 - Changed the image cleaning so that pixels with to many 'used'
3072 neighbors are left used (to get rid of 'holes' in events)
3073
3074 - Introduced more output to the camera displays
3075
3076 - Added an array of histograms (eg one hist per run), MHArray
3077
3078 - Added a _preliminary_ version of the reader for CT1 PreProc files
3079 (MCT1ReadPreProc)
3080
3081 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3082 (thanks to Raquel)
3083
3084 - added the first energy estimator (MEnergyEstParam, estimate.C,
3085 estfit.C) using a parametrization
3086
3087 - Added some new Monte Carlo paremeter containers used to store
3088 setup information from the MC chain (MMcConfigRunHeader,
3089 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3090
3091
3092
3093 *** Version 0.7 (2002/04/30)
3094
3095 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3096 the pedestal mean value was saved incorrectly. For files from
3097 this versions we substract 0.5 from the pedestal mean.
3098 WARNING: This may effect your results, so don't wonder...
3099
3100 - First implementation of an algorithm using only triggered events
3101 for the collection area calculation
3102
3103 - Ascii Output can now also be used for parameter containers which
3104 doesn't overload MParCointainer::AsciiWrite
3105
3106 - The Ascii Output is now also capable of writing single data members
3107 of one container
3108
3109 - You are now able to change the order of the values written to the
3110 ascii file
3111
3112 - You can now specify a conversion factor for each data member written
3113 to an ascii file. This may be usefull to change the units of the
3114 data member (eg. degrees instead of millimeters in case of the
3115 hillas parameters)
3116
3117 - Replaced old MHillas by a new structure which allows you to extend
3118 the parameters stored in MHillas very easily:
3119 see MHillas and MHillasExt
3120
3121 - Added classes to handle source dependancy of image parameters:
3122 see MHillasSrc
3123
3124 - Added container (MBinning) to have a standard input for the binning
3125 in different histograms (eg. the Energy bins should be the same in
3126 all histograms)
3127
3128 - Changed Hillas histograms from mm to deg
3129
3130 - Added the flexible binning to the hillas histograms
3131
3132 - Added a filter for the alpha parameter (MFAlpha)
3133
3134 - It is now possible to write single data members of a class object to
3135 an output stream instead of the whole container only
3136
3137 - Added a generalized filter for a data member:
3138 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3139
3140 - Added a generalized Filter parser for more difficult filter rules
3141 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3142
3143 - Added new Monte Carlo histograms:
3144 MHMcEnergyImpact and MHMcEfficiency
3145
3146 - Added many new histograms needed for the flux calculation.
3147
3148 - Added a generalized histograms which can fill and show up to three
3149 data members in either a one-, two- or three-dimensional histogram, eg:
3150 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3151
3152 - Added:
3153 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3154 * calculation of <Theta> as a function of time (MHThetabarTime)
3155 they are needed in the flux calculation in
3156 order to select for a given bin in Theta (or time) the appropriate
3157 effective collection area, which is assumed to be given as a function
3158 of Theta and the true energy
3159
3160 - Added calculation of the migration matrix in the energy
3161 (MHMcEnergyMigration):
3162 the migration matrix describes the migration from the true (E_true)
3163 to the estimated energy (E_est); it is needed to determine the
3164 distribution of E_true from the measured distribution of E_est
3165 by unfolding
3166
3167 - changed the color palette in the camera display to DeapSea.
3168
3169
3170
3171 *** Version 0.6 (2002/01/15)
3172
3173 - Introduce the option of disable pixels (MBlindPixels and
3174 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3175 able to deal with Star Field NSB.
3176
3177 - Fixed a bug in the pedestals substraction
3178
3179 - Introduced verbosity levels
3180
3181 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3182
3183 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3184 work correctly (thanks to Abelardo)
3185
3186 - Introduced correct treatment of the diffuse Night Sky Background
3187 and NSB (MMcPedestalNSB)
3188
3189 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3190
3191 - Introduced MMcRunHeaders which contains monte carlo run informations
3192
3193 - Added a 'Print'-Task (MPrint) which calls the Print function
3194 of a parameter container for each event
3195
3196 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3197
3198 - changes to be more efficient with root 3.02/06
3199
3200 - root 3.02/06 fixes:
3201 + the memory leak when reading MRawEvtData
3202 + loosing more time than necessary to update the progress bar
3203
3204 - MWriteAsciiFile is now capable of writing more than one container
3205 in a line. For example: To be able to write Monte Carlo and
3206 Hillas values (energy and alpha) in one line.
3207
3208
3209
3210 *** Version 0.5 (2001/11/06)
3211
3212 - Added new GUI functionality (Analysis)
3213
3214 - Added a camera display to be able to display events in the camera
3215 together with the calculated hillas ellipse
3216
3217 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3218 object at any state of the analysis, so that the output are several
3219 states
3220
3221 - Fixed a bug in the collection area error calculation
3222 (Thanks to Ciro and Abelardo)
3223
3224 - Fixed a bug which causes merpp to crash in some environments
3225
3226 - Implemented auto enabling scheme for Branches to speed up reading
3227 a lot (see MReadTree and MTask)
3228
3229 - Fixed a bug in the Histogram classes which caused histograms to
3230 be written to a file by MWriteRootFile without request
3231
3232 - changed the object I/O from the old stylish root I/O to the new
3233 'auto evolution scheme' This was done only for classes which are not
3234 yet used in Monte Carlo files, so that these files are still readable.
3235
3236 - Added support for a progress bar in MEvtLoop and MReadTree
3237 (see the Analysis Window in Mars for an example)
3238
3239 - Fixed a bug in the package creation which disturbed the conversion
3240 between a mars version unpacked from a tar file and the repository.
3241
3242 - Changed the code to writer merpped (converted into root format)
3243 raw files, to get faster (around 10%)
3244
3245
3246
3247 *** Version 0.4 (2001/09/20)
3248
3249 - This release is made to compile on a root version >= 3.00
3250
3251 - Fixed a bug which causes MReadTree to read the first file only
3252
3253 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3254
3255 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3256
3257 - Added a task to write several container to a root file (MWriteRootFile)
3258
3259 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3260
3261 - Added calculation of the collection area (MMcCollectionAreaCalc)
3262
3263 - fixed some bugs in the Hillas calculation
3264
3265 - added filters to be able to control the task execution dependent on
3266 a parameter (for example: the number of level 1 triggers in a MC-file)
3267
3268
3269
3270 *** Version 0.3 (2001/04/23)
3271
3272 - Many demo macros added
3273
3274 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3275
3276 - Hillas Calculation added
3277
3278 - Standard image cleaning available
3279
3280 - MReadTree is now able to handle more than one file
3281 (Remark: of the same structure)
3282
3283 - Now we are able to display events in a first version of the
3284 Camera event display. To do this we must run the macro
3285 "macros/readCT1.C" to read data from CT1.
3286
3287
3288
3289 *** Version 0.2 (2001/01/24)
3290
3291 - First Implementation of a Gui to read the raw data. Start the
3292 gui with the command mars.
3293
3294
3295
3296 *** Version 0.1 (2000/12/20)
3297
3298 - First official release 0.1
3299
3300 - Changes:
3301
3302 + changed calling style of MRawPixelIterator from do...while to
3303 while-loop