source: trunk/MagicSoft/Mars/NEWS@ 9465

Last change on this file since 9465 was 9464, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 135.0 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 * Added consistency check for two consecutive runs
11
12 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
13 has been disconnected and the L1 (L1TPU) has directly been connected
14 to another bit in the trigger pattern. This has been fixed by an
15 update of the decoding. Both bits are now or'ed together.
16
17 * Added a new camera layout MGeomCamFact which is the "four rectangular
18 pixels ordered in a hexagonal geometry" layout
19
20 ;showplot:
21
22 * If a file without a MStatusArray is opened all object (not just
23 canvases) found in the file are drawn. Note that this may result
24 in empty tabs.
25
26 ;ceres:
27
28 * The night sky noise is now scaled with the sensitive area and
29 is given in units per square centimeter
30
31 * Added the possibility to add a cut after the image parameter
32 calculation (''Cut'')
33
34 * updated the PDE of the GAPDs with a more reliable curve from
35 the meeting page (linear extrapolate below 350nm)
36
37 * The impact distribution in the event distrbutions is now
38 perpendicular to Alt/Az and the histogram is displayed in 1D
39
40 * The GAPD PDE has been updated
41
42 * PDEs and mirror reflectivities have been linearily extrapolated
43 to match the wavelegth range between 290nm and 900nm
44
45 * There is no default pulse shape anymoe it must be given in
46 the resource file
47
48 * Fixed a bug which caused the aerosol coefficient to be incorrectly
49 initialized. The effect might be random but seems to be small.
50
51 * Now accepts sequence files as input
52
53 * creation of pedestal and calibration files is now steered by
54 --mode (see ceres help)
55
56 * Instead of initializing the whole G-APD chip (all cells) before
57 each event (which is rather time consuming) a time evolution before
58 each event is now simulated which is enough to recovere every cell
59 to 99.999% of its response taking the background rate into account.
60 This is in total about a factor of ten faster and should not be
61 less accurate because under normal conditions the recovering cells
62 and the newly hitten cells will hardly be identical (due to
63 statistical reasons)
64
65 * improved the trigger algorithm which is now faster and allows easily
66 for multiplicity triggers
67
68 * The PDC flag in the file name is now correctly written
69
70 * A "PreCut" has been added which can be used after reading the events
71 to select them even before any calculation is done.
72
73 ;merpp:
74
75 * The new drive reports which contain also the status of the starguider
76 are now implemented, but the starting date (17/05/09) is preliminary.
77
78 ;callisto:
79
80 * Fixed a bug which prevented MAGIC Monte Carlo file from being
81 calibrated (ceres files worked)
82
83 ;star:
84
85 * allow to run thru even if discriminator threshold are missing
86 (they are not used for analysis so far anyway)
87
88 ;ganymed:
89
90 * added new starguider calibration for sequences since 1000534
91
92 ;database:
93
94 * added possiblity to query/plot data from certain source (with
95 regular expressions) in plotdb.php
96
97
98
99== Version 2.3 (2009/03/07) ==
100
101 ;SUGGESTION
102
103 * There is no need to re-run any data because no change took place which
104 could have an effect on the output. However, if you want a
105 meaningful SrcPos plot for your MCs in sponde you must re-process
106 star for your MCs first.
107
108 ;REMARK
109
110 * File produced with this release containing a camera geometry (which
111 are basically all files were produced as default) will not be readable
112 by older releases.
113
114 ;general
115
116 * fixed a few small bugs which could cause the display to crash in ganymed
117 and sponde
118
119 * in sequence file the date can now be omittet. In this case the
120 leading date with the underscore is missing in the expected filename
121
122 * the geometry class now also supports other geometries than just hexagons
123
124 ;automation
125
126 * added magnetic field Azimuth direction (ARRANG), currently
127 at ~ -7deg at La Palma
128
129 ;database
130
131 * plotdb.php: added default (sequences) for startup, added possibility
132 to set size of plot
133
134 * added a new table ''RunDataCheck'' which containes the rates after
135 image cleaning for every run which succeeded star. It can be
136 plotted using ''plotrundb.C''
137
138 ;merpp
139
140 * added support for Arehucas Version >= 200812140
141
142 * added support for Arehucas Version >= 200809030
143
144 ;mars
145
146 * The display now also displays the trigger pattern
147
148 * The display can now display ceres reflector (_R_) files
149
150 ;ceres
151
152 * added a uniformly distributed one-bin time jitter for the start of the
153 digitization. Otherwise the first photon would be digitized always with
154 the same alignment to the bins
155
156 * Added a plot showing the production height of the photons
157
158 * Moved the particle id from the event header to the run header
159
160 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
161
162 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
163
164 * Added many new options to control the tasks. For deatils see ''ceres.rc''
165
166 * Removed obsolete plots in pedestal and calibration mode
167
168 * Removed the non-NightSky photons from the plots where they are just
169 disturbing
170
171 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
172
173 * The daq event number now represents the readout number
174
175 * The camera ''electronics'' can now be ''switched off''
176
177 * A new tab ''Info'' now display basic things like the reflector
178 layout
179
180 * Improved reading speed for corsika files
181
182 * Improved memory handling (if a large ampount of memory was needed
183 for a single event all further events were stored in the same
184 memory and it was never freed, so the program took this memory
185 until the end)
186
187 * Converted the code from MMCS' reflector program to MSimAtmosphere
188 (instead of the tables build in for MAGIC Winter and Summer
189 atmosphere we use the values written by Corsika fitted to the
190 tabulated atmosphere given as input)
191
192 * For caluclating the displayed image parameters in ceres a basic
193 image cleaning removing isolated pixels is now done.
194
195 * The magnetic field direction (ARRANG) is now taken into account
196
197 * Added plot for the energy threshold after trigger ''Threshold''
198
199 * Added plot for the effective collection area after trigger ''TrigArea''
200
201 ;star
202
203 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
204
205 * The definition of fConcCore has slightly changed. The numbers
206 might decrease a little bit (the effect should be rather small)
207
208 ;ganymed
209
210 * added pointing model 328198
211
212 ;sponde
213
214 * The SrcPos plot for your MCs was so far meaningless because it just
215 displayes the MSrcPosCam data from the input star-files. Unfortunately,
216 this containes was never written to the star-files yet.
217
218 * A new Tab 'OnTime' is available which is an effective on-time
219 fit as in star but for all data. This is mainly for manual cross-check
220 of the effective on-time
221
222 * In some circumstances it might be necessary to re-calculate the
223 eff. on-time from the fit in the new tab, e.g. when a zenith distance
224 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
225
226 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
227 it to its own output file (for convinience)
228
229
230
231== Version 2.2 (2009/01/30) ==
232
233 ;SUGGESTION
234
235 * This release doesn't contain a major change which is expected to
236 change your results. Nevertheless there are small changes to
237 the calibration which can effect at least the first few hundred
238 events in any (mainly MUX and even more SUM) sequence a little bit.
239 So it is recommended although not necessary to reset your sequences
240 in the database before further processing.
241
242 ;NEW
243
244 * A first implementation of a Monte Carlo simulation program
245 (ceres - Camera Electronics and REflector Simulation) has been
246 implemented. It can simulate a full telescope already including
247 a complete reflector simulation and a flexible trigger and readout
248 simulation. Currently, no perfect setup is implemented and
249 especially the output of the program (data structure) should
250 be considered alpha state. Also the user interface is not yet
251 ready.
252
253 ;general
254
255 * All command line options after -- are now interpreted as
256 arguments (usually everything which doesn't start with a minus)
257 rather than options (usually everything which starts with a
258 minus). This allows to use file names starting with a -
259
260 * In all resource files you can now initialize the random number
261 generator. For details see: MJob::InitRandomNumberGenerator
262
263 * added a new program called ''readcorsika''. It's purpose is (in analogy
264 to readraw and readdaq) to read a Corsika output file (for now
265 only cherenkov output is supported) and print its contents in a
266 human readable form. It can also write the contents of this file
267 into a root-file.
268
269 * The calculation of the maximum distance to the origin in a MGeomCam
270 has been improved (edges might be further away than the sides).
271 This is just a tiny change but it might change the appearance of
272 the radial profiles a little bit.
273
274 * The default binning of the center-of-gravity plot has slightly been
275 increased
276
277 ;Database
278
279 * Added informations about the DC currents (fMinCurrents, fMedCurrents
280 and fMaxCurrents). The values are retrieved from the plots showing
281 the average DC currents of all pixels versus time.
282
283 * Websites with tables have now the opportunity to remove lines
284 ('-' button at beginning of each line) and get all lines back
285 ('+' at top of the column)
286
287 * Websites: added option to query only sequences containing sumtrigger
288 events
289
290 * Websites: added option to group by date (year, month, night) for runs
291 and sequences and enabled that combining of different group-bys,
292 e.g. status, date and source is possible
293
294 ;automatic analyis
295
296 * Rewritten producing plots in the web.
297 New plots, namely the output of plotoptical.C (extinction curve from
298 KVA), plotstat.C (status of the automatic analysis (percentage of
299 processed, analysed data etc.)) and plotusage.C (statistics of the
300 condor usage in the data center) has been are available now next to the
301 plots of plotdb.C
302 Mean values from the plots (output of the macro) are provided in a
303 txt file now.
304 The creation of the plots for callisto, star and ganymed in the web is
305 now steered via database. Consequently the plots are faster and
306 reliable up-to-date.
307 For all plots, a new layout is available facilitating the browsing
308 through the plots and providing additional information on the
309 displayed values. (tabs.php) These plots are linked from the DB
310 websites and the wiki.
311
312 ;statusdisplay
313
314 * The ''Loop'' entry in the menu bar now contains an option to pause
315 the loop and to process single events.
316
317 ;merpp
318
319 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
320 instead of RunHeaders)
321
322 * Now allows to merpp files newer than 2008/09/03.
323
324 * Added fixes for wrong (wrong or double) run- and file-numbers
325 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
326
327 ;callisto
328
329 * Extracting the pulse position for the pulse position check events
330 with sum trigger were denied. This decreased the statistics
331 extremely and therefor the resulting puse position was calculated
332 quite weak. Now sum events pass the calculation if and only if they
333 have also a level 1 trigger.
334
335 * the extraction of pedestal events and pulse position from the
336 first data events is now more automatic and makes sure that
337 a more precise number of events is extracted independent of
338 the ratio with which pedestal events or events with signals
339 are contained in the data.
340
341 * Updated Muon calibration constants for all MUX data (teh changes were
342 all smaller than 5%)
343
344 ;star
345
346 * For the calculation of the effective on time all sum-triggered events
347 were skipped. Now all Level1-triggeres events will pass. This might
348 result in a slight inaccuracy of the effective on time.
349
350 ;ganymed
351
352 * If the source position is more than 1deg away from the camera
353 center an error is raised now.
354
355 * Hopefully fixed the bug ''ganymed crashes when resized''
356
357 ;sponde
358
359 * Fixed a problem which causes the fitted spectral slope to be displayed
360 incorrectly. If you use MJSpectrum::FormFlux in your macros make
361 sure that the parameter 0 of your fit is negative.
362
363 * Added a histogram showing the read source position of your MCs
364
365
366
367== Version 2.1.1 (2008/08/04) ==
368
369 ;Database
370
371 * Added the median number of photo electrons from the calibration
372 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
373 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
374
375 * Added fTotOnTime, which is the on-time as given by the run-headers
376 (in contradiction to fAbsOnTime which comes from CC)
377
378 * Added new primaries for the new data structure (Magic II): for the
379 tables dealing with sequences (SequenceBuild Status, Sequences,
380 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
381 this is the telescope number (fTelescopeNumber) for the tables dealing
382 with runs (RunData and RunProcessStatus) this is in addition the file
383 number (fFileNumber)
384
385 * Added column fPriority to the status tables to be able to steer the order
386 in which the data is processed. As default the run, sequence and dataset
387 number are used.
388
389 ;automatic analyis
390
391 * Adapted scripts to the new data structure: They can handle now different
392 telescopes (getting the information as usual from the database).
393 The paths for Magic 2 are not yet implemented.
394
395 ;general
396
397 * should work now with root 5.20/00 (please note that root 5.20/00
398 we encounter crahses in the status display which are ot yet
399 understood)
400
401 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
402 instead of the base name of the file. This makes them easier to
403 access from the code
404
405 * Default Monte Carlo names in MSequence do not require the _E at
406 the end anymore
407
408 * where abrrevating a sequence file with a sequence number is possible
409 also "telescope:sequence" is now accepted, e.g.:
410 star 2:2000123 --out=output
411 see the programs' help for more details.
412
413 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
414 from the database. See the constructors for more details.
415
416 * MReadTree now supports friends
417
418 * MReadTree can now read also files not written by MARS and store
419 the data encapsulated in emulated MParContainers
420
421 * added a new starguider calibration valid since 15.1.08
422
423 ;showplot
424
425 * showplot can now read more than one file at once. This is especially
426 inetersting if reading files containing pure canvases
427
428 ;merpp
429
430 * we merpp the dc currents now also from the camera reports (they have
431 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
432
433 * In the automatic analysis we omit merpping of the currents from the
434 caco files and use the lower rate camera reports from the cc files
435 instead
436
437 * merpp has been redisigned to allow merpping of the cc-reports
438 of a whole sequence. This allows to design a very simple analysis:
439 mkdir output
440 ./callisto 100776 --out=output
441 ./merpp 100776 output
442 ./star 100776 --ind=output --out=output
443 Instead of the sequence number also sequence files are accepted.
444
445 * Implemented a fix for run-numbers between 1001348 and 1001396
446 which were incorrectly assigned by the cc.
447
448
449 ;callisto
450
451 * added a filter again which was was removed in the last release.
452 it removed the most brightest events. This should not change
453 any analysis result because these events are so bright that
454 they cannot be analysed anyway, but the bad-pixel plots doesn't
455 show outliers.
456
457 * updated muon calibration constants for the periods 51-57,
458 58-63 and 67-
459
460 ;star
461
462 * The camera currents are now displayed with the rate of the camera
463 reports instead of the caco reports
464
465 ;ganymed
466
467 * if mc camera files are new enough (>=8) the source position in the
468 camera is now calculated from the stored telscope and shower
469 orientation (Note, that this might not be suitable in all cases
470 depending on the aim of the study. These case still needs
471 implementation)
472
473
474
475== Version 2.1 (2008/06/18) ==
476
477 ;Database
478
479 * introduced average temperature and wind speed from star-files
480
481 * introduced average values from Pyrometer (mainly Cloudiness)
482
483 * introduced the ratio of accepted calibration events in the
484 calibration run
485
486 * introduced the average rates of the different trigger pattern,
487 e.g. the rate of pedestal and calibration events, from the signal-file
488
489 ;general
490
491 * fixed GroupBy options in plot*.C macros
492
493 * only display KVA points (not the Tuorla points) in plotoptical.C
494
495 * all programs now allow to add resources to the ones from the resource
496 file or overwrite them from the command line. This can be done like this
497 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
498 if something seems to be wrong you can debug what the program is doing
499 using the option --debug-env=3
500
501 * increased the diversity of debug levels. That also means that with -v3
502 you get now less output, i.e. only the output which is important for
503 an analysis. To get more output which helps for debugging try 4, 5 and 6.
504
505 * fixed a problem in the task synchronizing the reading of the reports
506 and the data stream. The effect was that in some circumstances the last
507 events of some trees could have been skipped. Since this is only a
508 very tiny part of the data no severe effect to your analysis results
509 is expected (an exception might be very short, i.e. singel runs,
510 datasets).
511
512 * Dataset file now allow to include the sequence file directly within
513 the dataset file and also allow to exclude single runs from the dataset.
514 (for more details see Class reference of MDataSet)
515
516 * Sequence files now allow for excluding runs from the analysis
517 (for more details see Class reference of MSequence)
518
519 * added code to process the sum-trigger flag
520
521 * the histogram classes MH3 and MHn now support profile histograms
522
523 * the histogram classes MH3 and MHn now support labels at the axis
524
525 * the Random Forest Train-classes (MJTRain*) now store the used datasets
526 in the output file
527
528 * the MFMagicCuts have a new option to allow a linear area cut (for
529 special studies)
530
531 * The liniking of the shared object is now done into a file defined
532 by 'mktemp'. This should be a local file system which accelerates
533 liniking a lot.
534
535 * The code has been prepared for compilation with root 5.18/00d
536
537 * The MHEnergyEst histogram now shows the distribution of
538 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
539 and (Eest-Emc)/Emc vs Emc.
540
541 * fixed mars (event display) for merpped raw-data and MC data
542
543 * adapted the synatx of sequence files to allow for the new run/file
544 scheme. For more details see class description of MSequence
545
546 ;showplot
547
548 * Added support for tiff files
549
550 * Added support for csv files (tables containing tab number,
551 name and title)
552
553 * Tabs now can have a title which is displayed in the postscript file
554
555 * When multiple file are written at once (e.g. pngs from a display)
556 it is now possible to use the tab name and or tab number in the
557 file name. For details see showplos's help.
558
559 ;merpp
560
561 * Implemented cc file version 2008-02-20/0
562
563 * Implemented cc file version 2008-05-19/0
564
565 * With new options merpping can be restricted (in addition to the
566 run-number) also by telescope and file number.
567 For details see "merpp --help"
568
569 * Implemented raw data format 11 (the most important change, except
570 from plenty of changes in the format definition, is the addition
571 of the file-number in the header) If nobody makes a mistake this
572 format should have the advantage that it is by definition forward
573 compatible, so old programs will be able to read newer formats.
574
575 * Added Pyrometer information to default output (stored in a new Tree
576 Pyrometer, needs a complete new merpp, i.e. new calibration)
577
578 * Merpping (also update) can now be restricted to one single report.
579 For example:
580 If you want to update an old file with Pyrometer information call
581 merpp --only=Pyrometer --update
582
583 ;callisto
584
585 * in the pedestal processing now at least 50 processed events are
586 required for succeeding.
587
588 * the signal and calib files now contain also the sequence information
589
590 * the two MPedestalCam in the calib file now have proper names
591 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
592
593 * Both pedestal cams now contain the number of events processed
594
595 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
596 i.e. for the extraction of the calibration pulses basically the average
597 over all events of the first slice instead of all slices was used.
598 Since pedestal and calibration constants are continously recalculated
599 this only effected the very first events of every sequence.
600
601 * For the extraction of the position of the maximum sample now the
602 extraction range is set automatically to the extraction window,
603 before the whole accessible range was used.
604
605 * If the number of samples in the events and the number of samples
606 in the run-header disagrees now an error is raised (this can
607 happen in not well simulated Monte Carlo files)
608
609 * In the case of MUX-data pedestal events with the lvl1 trigger flag
610 could survive into the pedestal calculation -- fixed.
611
612 * Tab "TrigPat" added showing the distribution of the trigger pattern
613 as found in the run-files (normalized with the run length)
614
615 * The selection of events from the trigger pattern has been improved.
616 If the trigger pattern is corrupted events won't pass anymore.
617
618 * Added a new command line option --dev-null to suppress output of
619 Y-files (this is useful for test cases)
620
621 * added a new tab "CalPos" showing the arrival time of extracted
622 interleaved calibration events
623
624 ;star
625
626 * the star file now contains also the sequence information
627
628 * Added a new command line option --dev-null to suppress output of
629 I-files (this is useful for test cases)
630
631 * Tab "Rate" added showing the distribution of the trigger pattern
632 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
633 the Y-files (normalized with the run length)
634
635 * The effective on-time calculation doesn't use events with only
636 sum-trigger anymore
637
638 * The data in the MHWeather tab has been reorganized. The never
639 working solar radiation has been removed and the data from
640 the pyrometer (cloudiness, air and sky temperature) is
641 displayed in addition.
642
643 ;ganymed/sponde
644
645 * Now data points are even shown correctly if they have error bars larger
646 than one sigma. Points with null or negative significances are omitted.
647
648 * DrawNicePlot now allows to set a projection range
649
650 * Updates pointing models. One is applied after the implementation
651 of the new LUTS in August, the other one is applied after the
652 next major change of the pointing model in October. Note that
653 these models are preliminary and give wrong results below Zd=65deg
654
655 ;sponde
656
657 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
658
659 * a new option "--force-runtime" is available. In case of very short
660 datasets (for light-curves) which are in the order of a few
661 minutes the calculated effective on-time is not very acurate because
662 it is quantizised in the order of a minute. Therefore you can switch
663 to using the real run-time instead (remakrt: this ignores any
664 dead-time!)
665
666 * a more analytical way is used to "fill" Monte Carlos into regions
667 of impact parameters which have not been simulated because the
668 trigger efficiency is assumed to be 0.
669
670 * estimated sensitivity curves for hi and lo zenith angles are shown
671 scaled to the correct observation time and collection area
672
673 * the Monte Carlo events after cuts are now written to the output file
674 if an output file given
675
676
677
678 *** Version 2.0 (2007/09/03)
679
680 - database: the position used for the pulse pos check was missing
681 in the callisto output and could thus not be filled into the DB.
682 Also the old values seemed not exactly the PulsePos used for
683 teh check.
684
685 - general: Resource file now allow an Include-Resource, i.e. you can
686 read a resource file with default settings, include it in your
687 resource file and overwrite the settings in your file. More than
688 one include file is allowed. Inclusions can be iterative.
689 Include: mydefaults.rc yourdefaults.rc
690 The resources in the first file have higher priority than the
691 second file.
692
693 - general: Now the output files (calib*.root, etc) also contain the
694 resource file (to check it open it in the TBrowser and choose Print()
695 from the context menu)
696
697 - general: Dataset files now allow to overwrite the default path
698 to search for sequence and data files. Note, that the program
699 option and individual resources will overwrite it. For example:
700 SequencePath: /magic/montecarlo/sequences
701 DataPath: /magic/montecarlo/star
702
703 - general: Fixed a problem with variables in MDataPhrase. It seems
704 that only optimdisp (didn't work) was effected.
705
706 - general: Some improvements to the optim and train processing. For
707 example the ststud window now got a proper title.
708
709 - general: The "Status Display: " was removed from the window title
710 within an Eventloop.
711
712 - general: added a new flexible histogram-class (MHn) which can be used
713 for example in testing after optimizations or training to produce
714 user defined histograms.
715
716 - general: The Random Forest now allows attaching an evaluation
717 function which is applied to its output. This allows to train
718 on whatever you like (eg. train on log10(energy), but return
719 energy)
720
721 - general: The Random Forest training of energy (trainenergy.c) and
722 disp (traindisp.C) has been improved by more graphical output to
723 judge the result.
724
725 - general: The training of energy (trainenergy.C) has been improved
726 a lot by training on a different quantity than energy. It gives
727 a result which is highly independant of the source spectrum
728 and shows lower bias than all other options.
729
730 - general: Dataset files are allowed to contain collections of
731 datasets. For more details see the class reference of MDataSet.
732
733 - general: The default WobbleMode in a datset file now (if not
734 overwritten) is "auto", i.e. wobble mode is set if the dataset
735 doesn't contain off-sequences.
736
737 - merpp: Merpp can read file format version 9 now. Please realize
738 that for file format version 9 the extraction range is different
739 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
740 the first and last 15 slices have been removed from all MUX data.
741
742 - mars: Similar to writing movies you can now select events which
743 should be displayed in your display. Therefore add the following
744 lines to your mars.rc:
745 MFEvtNumber.FileName: ganymed00223552.root
746 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
747 The input file can be a ganymed-file after (ganymed*.root) or
748 before (ganymed*-summary.root) file. For example to select all events
749 from your on sample after cuts (excluding the ThetaSq cut) use
750 MFEvtNumber.Selector: DataType.fVal>0.5
751 To show all events from your on-sample after quality cuts
752 use the summary file instead.
753
754 - mars: new ways to call mars are implemented. Instead
755 of calling
756 mars filename.root
757 you can now also use
758 mars sequence.txt
759 or
760 mars sequence.txt inputpath
761 or replace sequence.txt by the sequence number if the default
762 sequence file should be used.
763
764 - mars: The default size has been increased
765
766 - mars: There are two new heckboxes which allow to switch off
767 the calculated image parameters
768
769 - callisto: was broken for MCs... fixed.
770
771 - callisto: improved calculation of spline coefficients a lot. This
772 leads to a further improvement of the event rate calibrating MUX
773 data of about 15% (175evt/s instead of 150evt/s)
774
775 - callisto: finally the raw data we read is now real 16bit (with
776 10bit precision) for MUX data and not a stripped 8bit number
777 anymore. Due to scaling of the numbers (without precision loss
778 into an [0-256[ range, the final numbers for pedestal, pedestalrms
779 and extacted signal don't change. However, at all places where
780 raw data is directly accessed (eg. saturation and variation
781 limits in the signal- and pedestal-extraction) the numbers
782 refer still to the data's 16bit range.
783
784 - callisto: The maximum arrival time difference used in the bad
785 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
786 for both, old FADC and MUX-FADC, data.
787
788 - callisto: Be aware that callisto is now calibrating the arrival time
789 in nanoseconds rather than time slices. Also all following tasks
790 have been changed to assume ns units now. If you star data
791 calibrated with an older version it might be necessary to adapt
792 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
793 to obtain optimal results. The plot in the PulsePos tab
794 will now be in ns, too. This might also mean that the Muon
795 analysis in star might not work as perfect as expected as long
796 as old files read in.
797
798 - callisto: The calibration constants of earlier updates got lost
799 somehow. All constants have been updated.
800
801 - star: The PSF is now determined from the profile of the ArcWidth
802 instead of arcwidth/radius. The old way gave to much weight
803 to the bins with low statistics. The reference lines have been
804 updated.
805
806 - star: For speed reasons events suitable for the muon analysis
807 are now also preselected by fConcCOG<0.1 which seems to be a very
808 good preselector for muons.
809
810 - star: is now calculating a new timing parameter the Slope along
811 the major and minor axis of the shower. Therefore a numerical
812 solution of a line-fit is used. To use MHillasExt.fSlopeLong
813 and MHillasExt.fSlopeTrans don't forget to multiply it with
814 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
815
816 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
817 have been removed from MNewImagePar. They have never been good for
818 anything.
819
820 - star: Implemented a new recursive algorithm which is supposed to be
821 faster. Also implemented new cleaning oiptions, which are:
822 + CleanLevel0:
823 The cleaning level above single core pixels can be kept
824 + KeepIsolatedPixels:
825 Define whether single core pixels should be kept
826 + TimeLevel1:
827 The coincidence window in nanoseconds to single used neighbors
828 + TimeLevel2:
829 The coincidence window in nanoseconds to two used neighbors
830 + PostCleanType:
831 MOde in which a time dependent post cleaning should be applied
832 0: No post cleaning
833 1: Require for each used pixels at least one used neighbor
834 within a time-window of CleanLevel1
835 2: Require for each used pixels at least two used neighbor
836 within a time-window of CleanLevel2
837 3: Require first two and second one used neighbor
838 within a time-window of CleanLevel1 and fCleanLevel2
839 respectively
840 + RecoverIsolatedPixels:
841 - recoveres isolated core pixels if they have a used neighbor
842
843 - mars/star: The new default cleaning is:
844 + CleanLevel1: 6.0
845 + CleanLevel2: 3.0
846 + CleanTime1: 1.75
847 + CleanTime2: 1.75
848 + PostCleanType: 3
849
850 - star/ganymed: The old spark-cuts have been replaced by new ones.
851 These new spark cuts have been cross checked with the sequences
852 84720 (before splitter), 101041 (after splitter) and 223539 (new
853 FADCs). In all cases they seperate pretty well, but of course not
854 perfect. Monte Carlos have suggested to tighten the cuts a little
855 bit further at low sizes. This has been done.
856
857 - ganymed: IMPORTANT - The spark cuts have been changed to match
858 all available data more or less well. This might mean that for
859 YOUR data there are still sparks visible.
860 Whenever you do an analysis you have to make sure that NO sparks
861 survive your cuts!
862
863 - ganymed: The old hadronness and size cuts have gotten new indices
864 (10, 11). The old indices 8 and 9 now mean an additional condition
865 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
866 If you want to switch off this cut just move the line far away enough,
867 e.g. by setting c[9] to -500. Please update your ganymed.rc files
868 accordingly!
869 The unit of c[9] is deg. It is the dist at which your cut will
870 cross the slope==0. The unit of the slope is ns/deg. So if
871 you readin files calibrated with an older Mars-version you
872 have to adapt the default value for c[9] to the FADCs:
873 - Multiply by two for the MUX FADCs (run number > 200.000)
874 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
875 - Multiply by 42 for the meaning of life (run number = 200.000)
876
877 - ganymed: The old Cut0 is now called CutQ and is calculated before
878 the source position is caluclated. If you need a quality cut
879 including source dependant data (be very carefull with this!)
880 you have to use Cut0 instead.
881
882 - ganymed: now properly supports three off regions in wobble mode.
883 It will be the default from now on in ganymed_wobble.rc. To change
884 the number of off-regions use
885 NumOffSourcePositions: 1
886 in your ganymed.rc. Also by default no off-theta cut will be done
887 anymore so that you will get a background level higher than the
888 signal level in your ThetaSq plot for ThetaSq>0.2.
889 Due to this be carefull changing the scaling mode away from
890 "None". You will underestimate your signal if your scale interval
891 is not properly set.
892 (Rem: ThetaSqN is no longer needed)
893
894 - ganymed: is now storing the events of all (on- and off-)
895 source positions even in the case of more than one off-source
896 position. This should allow sponde to work properly and the
897 energy estimation is done correctly in all cases (without any
898 "nearest position" trick)
899
900 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
901 with a real pointing model for the starguider is done, calibrated
902 with more than thousand tpoints taken from this date on.
903
904 - ganymed: was broken for Wobble-MCs... fixed.
905
906 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
907 has changed. Note that your old ganymed.rc will be incompatible
908 with the new algorithms! Please check the ganymed.rc files and
909 the class description of MFMagicCuts for more information.
910 It is recommended at the moment to use identical Disp-Parametrizations
911 for on/off- and wobble-mode. If cuts are optimized only
912 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
913 should be optimized. All other values should be kept as they are.
914 If you want to do an anylsis without timing a parameters, you can
915 switch off the timing cuts by seeting parameter 7 to a very small
916 value (eg. -99). To remove the slope parameter from the disp
917 paremtrization set parameter 8 to 0.
918
919 - ganymed: The distribution of observation time versus zenith
920 angle is now shown for off- AND on-data.
921
922 - ganymed: The contents of the source position plot are no longer
923 averaged, thus a lot of (fake) events between the two wobble
924 positions have disappeared.
925
926 - ganymed: There is a new tab "CutT" it contains the VsSize plots
927 with the CutT, whihc is defined in ganymed.rc, applied. It
928 is resonable to use your theta-cut for it, to see if there is
929 something strange (sparks!) in your signal-region.
930
931 - ganymed: To choose a dataset from a collection in a dataset file
932 use the new command line option "--dataset=12345"
933
934 - optim, sponde: should now properly support three off-regions.
935 Just produce your ganymed summary files with three off-regions.
936 optim and sponde will automatically get all off events from
937 all off-regions from this file. Please do not forget to
938 set the scaling in optimwobble.C properly:
939 fit.SetScaleUser(1./3);
940 it is not yet read in automatically (will follow soon).
941 In the case of fixed Scale you can also use
942 cuts.SetThetaCut(MFMagicCuts::kOn);
943 no off-cut needed.
944 Be carefull in case of three off-regions when switching on
945 scale mode. Make sure that the scale interval is set correctly.
946
947 - sponde: sponde.rc and sponde_onoff.rc are now idetical
948
949 - sponde: the resouce files have been rewritten with a lot of
950 comments and a well working parametrization for an energy estimator
951
952 - sponde: In the estimated energy versus monte carlo energy plot the
953 contents where exchanged.... fixed.
954
955 - sponde: the so called "accurate"-mode has been removed. It didn't
956 give any improvement in accuracy, only decreased execution speed.
957
958 - sponde: the so called "simple"-mode has been removed. It didn't
959 give any improvement in simple.
960
961 - sponde: the so called "refill"-mode has been removed. It was anyhow
962 not implemented.
963
964 - sponde: now checks whether the theta distribution of your on-data
965 and the theta-distribution of your Monte Carlo sample (after
966 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
967 sample is incomplete) execution is stopped. Execution can be forced
968 using the new option --force-theta. Use this option with care!
969
970 - sponde: Proper collection areas can now be constructed also from
971 Monte Carlo samples generated with different maximum impact
972 parameters. Note that in previous version you neither got
973 a warning or failure, nor was there any obvious sign that the
974 collection area was overestimated due to usage of files with
975 different maximum impact parameters.
976
977 - sponde: If MC files with different lower energy limits are used
978 the primary MC spectrum is artificially completed down to the
979 lowest energy used at all. WARNING: that this gives correct
980 collection areas ONLY if none of the events in this region would
981 survive your cuts at all.
982
983 - sponde: the output file now contains more information about
984 the spectrum (eg. the full 2D collection area histogram).
985 Note, that this information can only be written to the file
986 if it is stored automatically via command line argument.
987 If you only store the status display from within the display
988 the information is lost.
989
990 - sponde: added a new tab "Disp". It shows the residual of the disp
991 (Disp-Dist) versus several parameters and it is meant to judge the
992 quality of the disp estimator. In the ideal case the residual is zero
993 and doesn't depend on any variable. The tab is displayed after
994 CutQ and Cut0.
995
996 - sponde: added a new tab "Energy". It shows the residual of the
997 energy (lg(estimated energy)-lg(monte carlo energy)) versus
998 several parameters and it is meant to judge the quality of the
999 energy estimator. In the ideal case the residual is zero
1000 and doesn't depend on any variable. In reality even a good estimator
1001 can show residuals versus Monte Carlo energy. The tab is displayed
1002 after all cuts.
1003
1004 - sponde: added a new tab "EventDist" showing the unweighted real
1005 absolute number of events of your sample after cuts. This tells
1006 you how many events with this energy you had in your MC files.
1007 The same information you get from the error bars of the weighted
1008 histograms, but this is less intuitive.
1009
1010 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1011 for comparison. It is not meant to show these curves in
1012 publications, they are only for production.
1013
1014 - sponde: The OriginalMC tree with the events produced by corsika
1015 is now processed only once
1016
1017 - sponde: Finally fixed most annoying bug, which has effected the
1018 last bin of the collection area. It was the problem that binnings
1019 of root histograms are from 1 to n (included) but there was a C-like
1020 loop in sponde from 0 to n (excluded). Now the loop also includes
1021 correctly under- and overflow-bins. The worse thing with this is,
1022 that for the events in the highest bin not only the bin-content
1023 was wrong, but also the weights applied to these events, which could
1024 in pricipal effect also other parts of the distribution (eg. due
1025 to energy estimation). Fortunately it effected only a few events
1026 in most cases.
1027
1028
1029
1030 *** Version 1.2 (2007/05/14)
1031
1032 - database: The database now has two new values Unsuitable50 and
1033 Unsuitable01. They express the number of pixels which are
1034 unsuitable for more than 50%, respectively more than 1%, of
1035 all calibrated event. It is a more accurate number than the
1036 previously used numbers, because they only take the first
1037 calibration (ignoring the interleaved calibrations) into account.
1038
1039 - database: The database now has two other new values UnsuitableMax and
1040 DeadMax. They express the maximum number of pixels which were
1041 unsuitable, respectively dead, during the sequence. Because
1042 of high pedestal rms (cars passing) a few events with very high
1043 numbers of unsuitable pixels can happen. Not to suffer from this
1044 effect we don't take the highest 0.1% of the numbers into account.
1045
1046 - general: fixed a bug which caused callisto and star to stop working
1047 properly because the callisto output was currupted
1048
1049 - general: a script called scripts/makemovie has been added which
1050 simplified the process of producing several movies from a single
1051 sequence with different setup.
1052
1053 - callisto: Some more code cleanup. Started to remove old obsolete
1054 code from cvs.
1055
1056 - callisto: The extraction of the pedestal with the extractor was
1057 not random. It seems that extracting at one position is still biased
1058 (for example in the first or last slices we could still suffer from
1059 switching noise) Now it is completely random.
1060
1061 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1062 pedestal files) individual pixels could be skipped due to high
1063 variations. This was already the case for the pedestal extraction
1064 from the lo-gains since the beginning and properly handled
1065 there, but was introduced in the extraction from the pedestal files
1066 a while ago. To calculate the average value it was still divided
1067 by the number of events procesed not by the number of summands
1068 really summed. This let to a pedestal which was a tiny amount too
1069 small (for a few piels in the order of 0.1%). This led to an slightly
1070 positive offset of the randomly extracted pedestal for a few pixels.
1071 I doubt that this has a big effect on the result, because the effect
1072 on the individual numbers is quite small. Due to this it is suggested
1073 that you rerun your calibration to make sure you are without any
1074 avoidable bias.
1075
1076 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1077 the median rms of the absolute arrival time and expressed in significance
1078 levels. This replaces the old meaning of an abolute upper limit. An
1079 absolute upper limit doesn't make much sense, because in our data
1080 all arrival times are shifted at the same time (in fact it might be
1081 a shift of the artificial trigger w.r.t. to the light flash).
1082
1083 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1084 of the number of unsuitable pixels over the whole sequence. This
1085 is usefull mainly to judge if an intermediate calibration had
1086 problems.
1087
1088 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1089 of the number of dead pixels over the whole sequence. Dead pixels
1090 in this context are unmapped pixels, i.e. pixels which could not
1091 be interpolated, and thus are ignored in the further analysis.
1092
1093 - callisto: It is now possible to use the position of the maximum
1094 of the spline as arrival time instead of the leading edge even
1095 when using the integral for the signal. Therefor set the extraction
1096 type to kIntegralRel ("IntegralRelative") and the relative height
1097 ("HeightTm") to -1:
1098 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1099 MJPedestalC1.ExtractSignal.HeightTm: -1
1100
1101
1102
1103
1104 *** Version 1.1 (2007/04/27)
1105
1106 - general: The new class MGeomCamDwarf contains the camera geometry
1107 for our prefered Dwarf camera and can be used to create general
1108 geometries of roundish or hexagonal cameras.
1109
1110 - mars: The default cleaning is now abolute 8.5/4.0.
1111
1112 - mars: The resource file mars.rc now contains examples for MUX data
1113
1114 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1115 data containing only 10-bit information is still cooked down to
1116 8-bit, by cutting away the lowest 8-bit.
1117
1118 - merpp: When reading raw data the data is now stored in a single
1119 array. The lo-gain array is obsolete. The interface stays the same.
1120
1121 - callisto: To process the new MUX data use the resource file
1122 callisto_mux.rc
1123
1124 - callisto: The -root and -raw options to read merpped raw data have
1125 been removed
1126
1127 - callisto: If the -mc option is given the sequence-name can now be
1128 replaced by the MC sequence number
1129
1130 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1131 -mc option can now be omitted
1132
1133 - callisto: Started further simplification by removing obsolete
1134 dependancies on MCalibIntensity*Cams.
1135
1136 - callisto: removed unsused intensity calibration from MJCalibration
1137 for further simplification
1138
1139 - callisto: for simplification removed references to
1140 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1141 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1142 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1143 (this should at minimum change nothing at all, and at maximum
1144 improve thing if these containers where somewhere not handled
1145 properly)
1146
1147 - callisto: Added the option to write an event movie. Please use
1148 this option with care (huge files) but exessively to understand
1149 our events. For further documentation please refer to the
1150 IACT wiki
1151 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1152
1153 - callisto: Improved binning for the pulse position check histogram
1154
1155 - callisto: The code calculating the pulse position checknow takes
1156 the pedestal into account
1157
1158 - callisto: The arrival time is now stored with full precision this
1159 helps to get rid of artefacts in histograms. For the signal this
1160 is not necessray because it is displayed in log-scale anyhow
1161
1162 - callisto: Fixed a problem with internal exclusions. Pixels which
1163 have once been marked as unsuitable didn't get the necessary
1164 histograms filled anymore to be rechecked with each interleaved
1165 calibration.
1166
1167 - callisto: The relative arrival time resolution (the rms of the
1168 relative arrival time offset) is now checked against its
1169 median and the median deviation, instead of the average
1170 plus an absolute offset.
1171
1172 - callisto: The relative arrival time offset is now calculated
1173 w.r.t. its median not w.r.t. to an artificial reference pixel.
1174
1175 - callisto: The relative time calibration now marks pixels with
1176 outlaying offset as unsuitable
1177
1178 - callisto: The interleaved relative time calibration has been switched
1179 on. The advantage is that pixels which are marked as outliers
1180 now can recover. An improvement over time is not expected, because
1181 the relative time calibration seems stable.
1182
1183 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1184 option can now be omitted.
1185
1186 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1187 or the option "-mc" is specified as default the monte carlo datacenter
1188 paths (/magic/montecarlo/...) are used if not overwritten in the
1189 dataset file.
1190
1191 - ganymed: The output files now contain run- and event-number for all
1192 events, accessible as RunNumber.fVal and EvtNumber.fVal
1193
1194 - ganymed: Added a plot showing the source position in the camera also
1195 for wobble mode
1196
1197 - ganymed: In addition to the existing task which can be setup to
1198 be executed after Cut1 a final task called "EstimateEnergy"
1199 has been added, executed before writing the final output
1200 (ganymed00000000.root). The task setup in all three cases
1201 can be choosen individually. (For all three(!) cases you
1202 can for example choose MRanForestCalc. For examples see all
1203 sponde*.rc and all ganymed*rc)
1204
1205 - ganymed: If a container "MEstimatedEnergy" is found in the
1206 parameter list (eg. because it was setup by MEstimateEnergy)
1207 it will be written to the output file.
1208
1209
1210
1211 *** Version 1.0 (2007/02/16)
1212
1213 - database: Website to plot values from the database has been added.
1214
1215 - database: The rate of spark events as found by star is now kept
1216 and the rate after cleaning is now with spark events subtracted
1217
1218 - general: The changes to the interpretation of phrases lead to
1219 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1220
1221 - general: Added example files how you can create your own calendar
1222 (eg. as christmas present) with Mars. Just run
1223 root macros/tutorials/calendar.C
1224
1225 - general: Added a possibility to display grouped data in the plotdb.C
1226 macro (and similar macros). This allows to plot hourly, nightly,
1227 weekly, monthly and yearly averages.
1228 For more details see the plotall function of the macro
1229
1230 - general: fixed the error display of the camera display. It showed
1231 wrong results.
1232
1233 - general: fixed a memory leak when reading many MStatusDisplays
1234
1235 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1236 between a spherical and a parabolic mirror
1237
1238 - callisto: We have a new pulse position check which takes the properties
1239 of the extractor automatically into account. So no need to set
1240 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1241 left is done. If possible the lo-gain extraction start and hi-gain
1242 extraction end is changed accordingly. If no proper extraction range
1243 can be set (hi-gain too much to the left) an error is raised.
1244
1245 - callisto: New swapped pixels have been found and corrected
1246
1247 - callisto: Redone the signal extraction this includes:
1248 + Unified the algorithms to extract the pedestal for all pedestal
1249 extractions done
1250 + Unification of hi- and lo-gain into one array
1251 + Unification of hi- and lo-gain extraction for Spline and
1252 Digital Filter (means now exactly the same algorithm is used,
1253 not a copy-and-pasted one)
1254 + Store pedestal subtracted data in a common place
1255 + Improved extraction algorithms. If the algorithms search a
1256 maximum but don't find one they don't return the maximum anymore
1257 + Improved the extraction such that a information for signal
1258 and time which is consistent is returned
1259 + replaced the numerical spline with a (not slower) analytical
1260 solution
1261 + Lowered the saturation limit from 250 to 245 to make sure that
1262 we are far away in all pixels from problems with the clock-noise
1263 + The start of the lo-gain extraction is calculated from the hi-gain
1264 arrival time. In case of saturation an estimation is used.
1265 + the hi-gain window was extended to slice 16. This allows extraction
1266 of very late pulses in single pixels or of huge hadron showers.
1267 + Now uses the lo-gain extraction range for pedestal extraction,
1268 not the hi-gain range in the lo-gain
1269
1270 - callisto: New hi-/lo-gain calibration constants have been produced
1271 for all periods from the statistic of the whole period. They are
1272 now used automatically depending on the periods. The old constants
1273 where deviation in avarega about 2%-3%. The constants are very
1274 stable from period to period (<<1%) except for exchanged channels.
1275 In a few cases the constants used so far were off by 1%-2% (maybe
1276 temperature effects?)
1277
1278 - callisto: To gain obsolete space we do not write the
1279 MPedestalFundamental anymore. Also calibration and bad pixel
1280 treatment is not done for it anymore because it has never been used.
1281
1282 - callisto: Fixed a bug in the seuqence handling which caused the
1283 light condition to be ignored
1284
1285 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1286 basically the same as "Cleaned" but the distribution devided into
1287 the events fullfilling a spark cut or being rejected by it.
1288 This cut can be changed from star.rc (see example inside) by
1289 the "SparkCut" directive
1290
1291 - star: Star displays now the average individual pixel-rate (IPR) versus
1292 time and the average discriminator threshold (DT) of all pixels.
1293
1294 - optim: fixed a problem with the optim-macros which was due to a bug
1295 in the new phrase parsing
1296
1297 - ganymed: To get a nice FalseSource plot (instead of the all-information
1298 debug plot displayed as a standard plot) use the context menu
1299 somewhere between the two upper plots, click on "DrawNicePlot"
1300 and enjoy the result. (It is the same context menu which contains
1301 the other options)
1302 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1303
1304 - ganymed/optim/train: The cut program, trainings- and optimization
1305 macros could run with less files found than expected from the
1306 sequence-files. No the execution is stopped in this case.
1307
1308 - ganymed: now stores the dataset in the output file with all information
1309 contained (as sequence number, sequence path, data path) so that the
1310 used dataset file can be recreated complete from the output
1311
1312 - sponde: now also allows the uasge of random forest
1313
1314 - sponde: added a plot showing the cut efficiency
1315
1316 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1317 errors (eg. effecting the collection area) because the errors of the
1318 two histograms were swapped in the calculation, which makes a difference
1319 in the case the histograms contains weighted events. Aditionally the
1320 totalarea was incorrectly taken into account, which results in too small
1321 errors, which makes a difference at low statistics were the errors
1322 or the collection area dominate.
1323
1324
1325
1326 *** Version 0.10.3 (2006/10/23)
1327
1328 - database: Implemented ObservationMode flag in websites.
1329
1330 - database: For sequences there is now also the stoptime available on the
1331 websites.
1332
1333 - database: Removed ManuallyChanged flag from sequence-info websites,
1334 as it is not needed anymore with the new sequence building algorithm.
1335
1336 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1337 Class for calculation of confidence intervals (upper limits).
1338 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1339 Please read the class instruction of TRolke for more information.
1340
1341 - general: The programs now return 0xfe if the requested resource file
1342 doesn't exist.
1343
1344 - general: Errors comming from root itself are now not output to
1345 stderr anymore but to our default (colored) log-stream.
1346
1347 - general: Changed the interface to TFormula such that now everything
1348 is parsed by TFormula, which should allow to use phrases even
1349 without paranthesis correctly parsed.
1350
1351 - callisto: replaced the AdHoc number of effective integration slices
1352 in the digital filter by an average of the correct number, averaged
1353 over all possible set of weights. This also gives correct numbers
1354 for the lo-gains which were totally wrong before.
1355
1356 - callisto: drastically reduced memory consumption by not storing
1357 all intermediate calibration results in memory anymore (we might
1358 write them into a file in the future)
1359
1360 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1361 debug plot displayed as a standard plot) use the context menu
1362 somewhere between the two upper plots, click on "DrawNicePlot"
1363 and enjoy the result. (It is the same context menu which contains
1364 the "DrawAll" option)
1365 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1366
1367
1368
1369 *** Version 0.10.2 (2006/10/15)
1370
1371 - general: changed the building of the sequence files such, that
1372 the source-/project name in case of wobble-sources is not the
1373 source/project of the first data run anymore but the new generalized
1374 wobble source/project
1375
1376 - general: Added some functions to MAstro to calculate sun and
1377 moon properties
1378
1379 - general: Added two new macros (starvisday.C and starvisyear.C)
1380 which allow to plot the visibility of several stars in one day
1381 or of one star along one year
1382
1383
1384
1385 *** Version 0.10.1 (2006/10/11)
1386
1387 - general: HTML logging output was distorted... fixed.
1388
1389 - general: Changed the writing of the sequencefiles such that only
1390 as many pedestal files as giving at least 1000 pedestal events which
1391 are nearby the first calibration run are used as pedestal runs
1392
1393 - sponde: In the calculation of the collection area(s) and the
1394 distribution for MOnte Carlo and estimated energy the error
1395 calculation was wrong because root didn't take the errors
1396 properly into account... fixed.
1397
1398
1399
1400 *** Version 0.10 (2006/10/10)
1401
1402 - general: all executables now check consistency of the root version
1403 installed with the root version used for compilation. The return
1404 code in this case is 255.
1405
1406 - general: The algorithm to build seqeunces has been redesigned
1407 completly. It is now more flexible in terms of a resource file
1408 resources/sequences.rc which can be used to partly overwrite
1409 the default algorithm and defined the important part of the
1410 algorithm. It also takes correctly into account several ways
1411 of taking wobble-data. Currently the new algorithm doesn't take
1412 the number of pedestal events anymore into account (so a sequence
1413 could have much less than 1000 pedestal events and data runs are
1414 no-more used instead)
1415
1416 - general: a lot of small changes to make the code compatible with
1417 root 5.12/00 and gcc 4.1
1418
1419 - general: Fixed some warnings thrown if more warnings are switched
1420 on in the compiler
1421
1422 - general: Added a function to MMath which returns the Median of
1423 the distribution abs(y[i]-median) but at 68:32 division instead
1424 of 50:50, which is somehow the median counterpart of the rms.
1425
1426 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1427 even if they are compressed with gzip (recommended compression
1428 is with "-1")
1429
1430 - showplot:
1431 + batch mode creation of image files now works with root 5.12/00
1432 + added support for writing bmp (though it never produces
1433 bmp which can be read by programs like xv or gimp)
1434 + added support for xml
1435 + added new option to start the display with a different size, by
1436 --display-width=nnn or --display-height=nnn
1437 + added options to define the canvas size when the display is started
1438 --canvas-width=nnn or --canvas-height=nnn
1439 the option can also be used for batch-mode conversion
1440 + added an option which automatically fits the display size to the
1441 desktop-size: --auto-size
1442
1443 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1444
1445 - merpp: allow the reports to have 1000ms due to a bug in the camera
1446 program.
1447
1448 - callisto: New swapped pixels have been found and corrected. For
1449 details see MRawRunHeader::FixAssignment()
1450
1451 - callisto: Callisto now raises an error if one of the input files could
1452 not be opened.
1453
1454 - callisto: In some rare cases it could happen that in the signal
1455 extraction of the digital filter the extractor returned nonsense
1456 results due a wrong initializion of a variable (this happens in
1457 cases in which the extracted signal is exactly zero or the
1458 digital filter couldn't slide because of a too small extraction
1459 window, which could happen in the lo-gain extraction)
1460
1461 - callisto: The lo-gains have been marked as valid in some cases
1462 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1463 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1464 smaller than the number of slices (fLoGainWindowSize) needed
1465 by the lo-gain extractor
1466
1467 - callisto: Updated absolute calibration constants (muon calibration)
1468
1469 - callisto: fixed a bug which caused the hi-gain saturation not
1470 to be handled properly in the spline (the position of the
1471 saturation was calculated incorrectly)
1472
1473 - callisto: fixed a bug which gave weird results if hi- _and_
1474 lo-gain could not be extracted properly. In some cases hi-
1475 and lo-gain have not been extracted at all and the random result
1476 got calibrated. In other cases the hi-gain was saturating and the
1477 lo-gain has not been extracted. For this a completly arbitraty
1478 scale factor was applied to the result from extracting the
1479 charge of the saturating hi-gain.
1480
1481 - callisto: improves handling of extracted signal if lo- and/or
1482 hi-gain could not be extracted properly. If no appropriate
1483 calibration of either the signal or the arrival time is possible
1484 the pixel is now markes as unsuitable instead of estimated.
1485
1486 - callisto: Fixed a problem in the spline extraction which gave
1487 weird results if the signal was extracted from the first (and
1488 highest) slice (as a workaround extraction from the first
1489 slice has been forbidden)
1490
1491 - callisto: Fixed a bug regarding the use of the QE which doesn't
1492 effect the result because the default is used anyhow.
1493 (The bug was there since 14/07/2005)
1494
1495 - callisto: Changed the default for fgLoGainStartShift to -2.4
1496
1497 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1498 factors to be always 10 for all pixels as soon as the first
1499 calibration update has happend.
1500
1501 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1502 was off by more than one slice (which gives wrong values for
1503 pixels which have saturated the hi-gain) This was a problem
1504 mainly for timing studies, not so much for the automatic standard
1505 analysis. Also the values for the Spline have been changed slightly:
1506 + Digital Filter from 1.70 to 0.95
1507 + Spline from 1.39 to 1.30
1508 The numbers were sorted out by an extensive test in the
1509 test-database.
1510
1511 - callisto: Removed the tab showing the average calibrated arrival
1512 time. It never gave useful information.
1513
1514 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1515 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1516 and both were extracted because the hi-gain was above the
1517 LoGainSwitch.
1518
1519 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1520 lo-gain pulse position (after application of LoGainOffset, which
1521 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1522 have saturated and both were extracted because the hi-gain was above
1523 the LoGainSwitch.
1524
1525 - callisto: After extensive tests a new threshold level for determination
1526 of the pulse position has been found at 50phe. This is due to the
1527 fact that for lower pulses the arrival time changes its average
1528 behaviour dramatically. It tends to the average of the extraction
1529 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1530
1531 - callisto: Added two more plots to the calibration part. The average
1532 extracted signal and the average extracted arrival time as
1533 extracted by the signal extractor (This can help debugging problems
1534 because it doesn't involve a fit)
1535
1536 - star: changed the fit for the effective on time such that initial
1537 values are calculated automatically now instead of using build
1538 in values. This makes the fit more indepedant of the underlaying
1539 rates. With a test of ~350 sequences in the test database it could
1540 be shown that the new fit gives the same result +/-1sek.
1541 The highest deviation was +5s the lowest -10s. You can now control
1542 the bahaviour with two resource values:
1543 MHEffectiveOnTime.FistBin: 3
1544 MHEffectiveOnTime.NumEvents: 12000
1545 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1546 from the resulting gamma candidates
1547
1548 - star: The Center histogram in MHHillas is now by default displayed
1549 with the colz draw-option
1550
1551 - ganymed: now produces valid error codes if failed
1552
1553 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1554 with the option "hadronness" instead of "area" or "both" if
1555 you want to use both cuts. The hadronness cut includes a fixed
1556 cut in hadronness (index 8) and a fixed cut in size (index 9).
1557
1558 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1559 the M3Long of the anti source to be not properly evaluated
1560 (actually is was evaluated as a unique random number) in case
1561 of optimization with anti-theta cut switched on. This might have
1562 lead to improper, but not necessarily wrong, optimization results.
1563
1564 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1565 how to use random forest
1566
1567 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1568 ganymed_onoff.rc. Seems to be unintentional that they were different.
1569
1570 - sponde: Since the introduction of the possibility to define a
1571 normalization energy instead of using the integral the default
1572 was not using the integral anymore but a normalization energy of
1573 1GeV. It is now the integral again.
1574
1575 - sponde: Fixed a problem in the weighting which did not allow
1576 a MC slope of -1.
1577
1578
1579
1580 *** Version 0.9.6 (2006/05/24)
1581
1582 - general: changed the binning of the azimuthal profile of the camera
1583 such that it is aligned with the 60deg boundaries.
1584
1585 - merpp: better handling of problems with the TH, TD part of the
1586 CC-REPORT for files older than 200507190 and 200412210
1587 respectively
1588
1589 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1590
1591 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1592
1593 - callisto: if an arrival time is extracted outside the fadc range is
1594 was set to the boundary before. Now a random number is assigned
1595 instead to avoid unfortunate coincidences of arrival times just
1596 by this arbitrary value.
1597
1598 - callisto: added a new option to callisto.rc which allows
1599 to set the maximum arrival time difference allowed for the
1600 badpixel algorithm to determin whether a pixels belongs to a shower:
1601 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1602
1603 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1604 to 0.9 as suggested by Stefan due to a recent study on the fraction
1605 of pixels surviving the image cleaning
1606
1607 - callisto: switched off error in case of "pulse is too much to the left"
1608
1609 - callisto: The extraction window is not adapted anymore. This means that
1610 the pulse is extracted from the full range. The draw-back is that the
1611 background (pedestal) will become slightly higher. Switching on/off
1612 the PulsePosCheck in the callisto.rc only effects filling the
1613 histograms.
1614 WARNING: If the pulse is too much to the left data is calibrated!
1615 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1616 in the database to make sure that your data is valid!
1617
1618 - star: Show also the number of stars correlated correctly by the
1619 starguider
1620
1621 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1622 than one off-source region in wobble-mode. To use it add the following to
1623 your ganymed_wobble.rc:
1624 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1625 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1626 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1627 + Cut1.ThetaCut: None
1628 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1629
1630 - ganymed: in the case the latest report is older than a default (currently
1631 one minute) and the current report will be skip the starguider
1632 correction and calibration will be reset. The maximum age can be
1633 setup from ganymed.rc by (minutes):
1634 MPointingDevCalc.MaxAge: 1.5
1635
1636 - ganymed: A first implementation showing all size-bins for the theta-sq
1637 resp. alpha-plots in a single tab automatically
1638
1639
1640
1641 *** Version 0.9.5.1 (2006/05/05)
1642
1643 - general: Added a new option "zdiff" to the Makefile which runs
1644 "cvs diff" as "make diff" would do, but with compression
1645
1646 - general: accelerated MTFillMatrix (used for eample in all training
1647 and optimization macros) by skipping some obsolete calles in the
1648 eventloop the first and second loop could be accelerated by ~20%
1649
1650 - general: Added a missing feature in the MFilterList class which
1651 prevented MFEnergySlope from working correctly in trainenergy.C
1652
1653 - general: Accelerated the random forest training and usage a bit
1654
1655 - merpp: Adapted to new raw data file format version 6
1656
1657 - merpp: fixed a problem with reading the starguider reports
1658 after 6.3.2006
1659
1660 - callisto: At some times six pixels had to be exchanged manually in the
1661 data. If the pixels to be swaped are both not found, an error was raised
1662 and calibration was stopped. Now it is assumed they are intentially not
1663 mapped and the Error has been changed to a Warning.
1664
1665 - star: Added new image cleaning based on the arrival time of the shower.
1666 The new cleaning can be accessed using the parameter "Time" instead of
1667 the the old one (like "Absolute) in the star.rc-file.
1668 Recommended parameters:
1669 + MImgCleanStd.CleanLevel1: 8.2
1670 + MImgCleanStd.CleanLevel2: 5
1671 + MImgCleanStd.CleanRings: 2
1672 + MImgCleanStd.KeepSinglePixels: No
1673
1674 - star: Simplified the calculation of the effective on time. By letting
1675 the fit start in the third bin the result should become more stable.
1676 The fit quality is now ignored for the theta-plot which is not used
1677 in the analysis later. Still better pre-cut which, for example,
1678 remove events triggered by car-light (rate changing on a short
1679 time-scale) are missing.
1680
1681 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1682 for optimization (kWeakSource) which is suggested by the Berlin
1683 people for weak sources.
1684
1685 - macros: plotdb.C:
1686 + if no dataset and no time-interval is given only sequences with
1687 an effective on-time above five minutes are plotted anymore
1688 + added a new tab "RelTime" displaying the relative on-time
1689 (effective on-time divided by the observation time)
1690
1691 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1692 the optimization became a lot faster
1693
1694 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1695 To display them just delete the pads displayed on top.
1696
1697 - ganymed: fixed a bug which could cause strange behaviour in wobble
1698 mode if no starguider information was available due to an incorrect
1699 initialization of the starguider calibration
1700
1701 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1702 be changed from within the plot. It can also be setup from the
1703 resource file using:
1704 + MHDisp.fScaleMin: 0.325
1705 + MHDisp.fScaleMax: 0.475
1706
1707 - ganymed, showplot: Fixed a problem with the fit to the off-data
1708 (HistOff) which could cause a time lag or an inifinite loop.
1709 The bug did not effect the results at all.
1710
1711 - sponde: Added a new tab showing the effective collection area after
1712 trigger (including the software trigger)
1713
1714 - sponde: MMcSpectrumWeight has a new option which allows to define
1715 the scaling factor not by the integral of the events but at
1716 a defined energy:
1717 e.g. MMcSpectrumWeight.NormEnergy: 200
1718
1719 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1720 eventloops the loop could be accelerated by ~20%
1721
1722
1723
1724 *** Version 0.9.5 (2006/03/13)
1725
1726 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1727 and added the standard Disp-parametrization
1728
1729 - macros: added a new macro datacenter/macros/plotstat.C allowing
1730 to plot statistics about the data processing
1731
1732 - macros: added a new macro to plot the muon correction coefficients
1733 versus period (macros/plot/mucal.C)
1734
1735 - showplot: path inflation for ganymed files was broken
1736
1737 - callisto: Fixed an important bug. When the number of saturating pixels
1738 were calculated the bad pixel information already available from the
1739 calibration was ignored. This yields wrong values in case pixels
1740 are broken and saturate all the time or randomly.
1741
1742 - callisto: Updated Muon calibration constants. Spline data now also uses
1743 different values for different periods
1744
1745 - star: The time-evolution shown in the effective on-time plot now displays
1746 the axis range (if there are no holes it should be similar to the
1747 effective on-time)
1748
1749 - star: Added two new image parameters:
1750 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1751 the three pixels next to the center of gravity and the size
1752 + MNewImagePar.fConcCore: The ratio of the signals of all
1753 pixels inside or touching the ellipse and the size
1754
1755 - ganymed: now stops in requested source isn't found in catalog file
1756
1757 - ganymed: Many improvements to the phi-plot in wobble mode:
1758 + with a template the ideal background is displayed
1759 + a possible camera inhomogeneity is taken into account
1760 + the anti theta cut is better supported
1761 + the phi cut is automatically calculated from the theta cut
1762 See the examples in ganymed_wobble.rc for more details.
1763
1764 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1765 times the bin-width instead of the absolute energy
1766
1767 - ganymed: New cuts for on/off and wobble mode
1768
1769 - ganymed: The smearing of the False Source plot has been increased
1770 to 0.06
1771
1772 - ganymed: The starguider calibration can now be changed from the
1773 resource file.
1774 See the examples in ganymed*.rc for more details.
1775
1776 - ganymed: added a new option for on-/off-observations
1777 MJCut.RandomSourcePosition
1778 If switched on the distribution of observation time of the source
1779 position in the camera is calculated from the on-data and randomly
1780 applied with this distrbution to the off-data.
1781
1782 - ganymed: by skipping some obsolete calles in the eventloop the
1783 first and second loop could be accelerated by ~20%
1784
1785 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1786 position in the off-data randomly according to its distribution in the
1787 on-data.
1788
1789
1790
1791 *** Version 0.9.4.3 (2006/02/13)
1792
1793 - general: Fixed a bug in most of the programs which prevented the
1794 compile date in the startup message to be displayed
1795
1796 - general: Simplified program calls. The following abbreviations
1797 are now possible:
1798 showlog callisto 55599
1799 showplot signal 55599
1800 star 55599
1801 callisto 55999
1802 ganymed 2
1803 In this cases the corrsponding root-, log-, sequence- or dataset-
1804 filename is automatically compiled using the default datacenter
1805 paths ("/magic/*")
1806
1807 - general: Fixed a long outstanding bug which made axis tick marks
1808 disappear if MDataFormula was used (eg. abs(x))
1809
1810 - general: Updated MMath with new functions to calculate the results of
1811 a exponential, logarithmic and powerlaw fits analytically.
1812
1813 - general: Updated some macros with comments:
1814 + macros/optim/optimdisp.C
1815 + macros/optim/optimenergy.C
1816 + macros/optim/optimwobble.C:
1817
1818 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1819 files) now allows adding a pre-cut like in the optimization. E.g. this
1820 is useful to perform g/h-separation cuts before training the random
1821 forest.
1822
1823 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1824 correctly assigned in the raw data assignement table. A fix to correct
1825 the assignment tabel have been implemented.
1826
1827 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1828 by 90, 180 and 270 deg.
1829
1830 - general: the macro plotdb.C now allows to highlight sequences belonging
1831 to a datset. For more details see the descritions in the macro.
1832
1833 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1834 of the display, it gave wrong results espacially for big sizes.
1835 Now the embedded canvas should always have a ratio width/height=3/2.
1836 The "Size" options have been updated with values fitting the 3/2
1837 size ratio.
1838
1839 - RanForest:
1840 + Updated the random forest classes to support also the
1841 regression method implemented by Thomas H.
1842 + added new tutorial macro how to train the random forest
1843 for energy estimation (macros/optim/rfenergyest.C)
1844 + new classes to train the random forest (still in development)
1845 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1846 + new tutorial macros for random forest training in macros/train
1847 trainenergy.C, traindisp.C, trainseparation.C
1848
1849 - mars: now allows to setup a cut in the resource file mars.rc to choose
1850 the events to be displayed, eg:
1851 Cut.Condition: {0} && {1}
1852 Cut.0: MHillas.fSize>100
1853 Cut.1: MHillas.fSize<900
1854
1855 - merpp: Made aware of the new .rep format 200510250. This includes
1856 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1857 the discriminator thresholds (MCameraTD) and the disciminator
1858 delays (MCameraTD). All of them come with the CC report and are therefor
1859 written to the CC tree.
1860
1861 - callisto: fixed a bug in the calculation of the arrival times in
1862 the Digital Filter. They were all shifted by the same amount
1863 fHiGainFirst. This caused an offset in the order of the position of
1864 the left border of the extraction window in the times calculated
1865 from high-gain and from low-gain. The bug effected only the absolute
1866 arrival times. The bug was there since 30.1.2005.
1867
1868 - callisto: Changed the ExtractionWindow for the pulse position check
1869 such that the camera inhomogeneity becomes as less as possible and
1870 comparable to the pulso position check switched off. More details
1871 on the study will be given at our result web-page.
1872
1873 - ganymed: ganymed.rc, ganymed_onoff.rc:
1874 changed to new cuts trained with 1ES1218 and Crab-data
1875 for maximum sigma*log10(excess)
1876
1877 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1878 a new option was implemented to estimate Disp (CalcDisp)
1879
1880 - ganymed: Implemented two new options which allow
1881 to overwrite the default path to search for the sequence files
1882 --ins=/magic/sequences
1883 and where to search for the image data
1884 --ind=/magic/data/star
1885
1886 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1887 dx/dy from the resource file by
1888 MSrcPosCorrect.Dx
1889 MSrcPosCorrect.Dy
1890
1891 - ganymed: fixed reading the source catalog. Only as many chars
1892 as the requested source name had were compared (If a source
1893 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1894 were requested it could happen that the coordinates of
1895 "1ES1218" were read) The source coordinates are now printed
1896 in addition to its name to the logging output.
1897
1898 - ganymed: changed the background fit in the case of a ThetaSq function
1899 from a polynomial to a exponential, this should give a big improvement
1900 for on-only analysis'
1901
1902 - ganymed/sponde: Calculation of the error of single size-/energy-
1903 bins now uses Li/Ma (5) instead of LiMa (17)
1904
1905 - sponde: Added a plot E^2*dN/dE
1906
1907 - sponde: The energy estimator plot should now show values like
1908 they are commonly used.
1909
1910 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1911 (a powerlaw with cutoff didn't work before)
1912
1913
1914
1915 *** Version 0.9.4.2 (2005/10/01)
1916
1917 - general: added new tutorial macro macros/tutorials/threshold.C:
1918 how to calculate the threshold
1919
1920 - general: added a new game. Start it from the interpreter with
1921 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1922 and MagicReversi)
1923
1924 - general: neighbor pixels in MGeoms are now sorted clockwise
1925
1926 - merpp: made aware of new format 20050829-0
1927
1928 - callisto: New scale factors from muon analysis, stored in new
1929 resource file resources/calibration.rc
1930
1931 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1932 the eventloop if something went wrong. This is necessary for the
1933 automatic processing
1934
1935 - callisto: Implemented a new treatment for the time information
1936 developed by S.Ruegamer, this should give much better response than
1937 the old very primitive algorithm. This is especially important
1938 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1939 treatment was buggy! As neighbor pixels to interpolate the
1940 arrival times always the pixels 0 to 5 were taken)
1941
1942 - callisto: In addition to the new treatment of arrival times the
1943 decision of the treatment whether a pixel contains shower
1944 information or not is used to improve the signal interpolation
1945 further. Previously interpolated pixels showed a non-zero signal
1946 do the peak searching signal extractors. Having a signal pixel
1947 beside raised the signal above the cleaning level. Thus the
1948 pixel survived cleaning to often but with a too low mean signal.
1949 By replacing empty pixels with a gaus (mean and rms from the
1950 corresponding Area entries in MPedPhotCam) this effect can
1951 be supressed.
1952
1953 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1954 got lost when the events were stored by the calibration... fixed.
1955 (This was no problem for normal image cleaning because the pixel
1956 content was artificially set to 0 not surviving standard cleaning
1957 algorithm)
1958
1959 - callisto: Fixed a bug which caused the random and peak-search pedestal
1960 extracted with an extractor to be exchanged for the first (roughly)
1961 500 events (*Extractor and *ExtractorRndm).
1962 (They were simply exchanged in callisto.cc) This bug might have been
1963 introduced in Mars 0.9.4 when the order of calculation of the two
1964 types of pedestal in callisto got exchanged. The bug only effects
1965 the first seconds of data of each sequence.
1966
1967 - star: Taking the arrival time of Muons into account the calculation
1968 of the parameters could be made independant of the noise
1969 (pedestal rms). The dependance was due to the bias of the peak search
1970 extractor. Now only a ZA dependamcy is left which is not yet fully
1971 understood.
1972
1973 - ganymed: The sequences were still not sorted correctly in any case,
1974 because they were sorted by the full qualified path name. Now they
1975 are sorted by their sequence number.
1976
1977 - ganymed: new values for the spark-event-cut
1978
1979 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1980
1981
1982
1983 *** Version 0.9.4.1 (2005/08/18)
1984
1985 - callisto: fixed some problems with the calibration in case of
1986 inteleaved events. Therefor the final and some intermediate
1987 fits are skipped which would take place on partly filled #
1988 histograms and gave wrong results or failed completely.
1989
1990 - callisto: If the intermediate finalization of the histograms
1991 calculating the mean charge of the calibration signal fails
1992 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1993
1994 - ganymed: Fixed some bugs which caused problems in On-only mode.
1995 Still the false source plot doesn't give reasonable results.
1996
1997
1998
1999 *** Version 0.9.4 (2005/08/05)
2000
2001 - general: Fixed the ZA binning. It did not correctly fit the
2002 MC binning
2003
2004 - general: Added a class to correct for the missfocussing in
2005 April (MSrcPosCorrect)
2006
2007 - general: Random Forest energy estimator should now work properly
2008
2009 - general: MHCamera now displays the profiles in deg instead of mm
2010
2011 - general: MH::SetPalette offers a lot of new palettes
2012
2013 - general: MHillas - the case of CorrXY==0 is now handled properly
2014
2015 - general: implemented the possibility to change the line and
2016 marker style of a sky-grid drawn by MAstroCatalog
2017
2018 - general: Runs in sequences and datasets are now automatically
2019 ordered (it is assumed that the order of their filenames correctly
2020 represents the order of observations) to ensure correct reading
2021 of the subsystem data
2022
2023 - general: Runs cannot be added to a sequence twice anymore. Also
2024 Sequences cannot be added twice anymore to a dataset.
2025
2026 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2027 It gave wrong results by 1./2pi
2028
2029 - showplot: got a new option to start a root interpreter, too
2030
2031 - mars: now displays a rough estimate of Disp and the third moment
2032
2033 - mars: now displays the event time MTime if available
2034
2035 - mars: show muon parameters graphically
2036
2037 - mars: now the file to open can be given as commandline
2038 argument
2039
2040 - merpp: Added support for new arehucas version >= 200507190
2041 implementing values for three temperature sensors in the
2042 counting house (MCameraAUX) and the name of the HV settings file
2043 (MCameraHV).
2044
2045 - merrp: Also fixed some problems with wrong versions numbers stated
2046 by arehucas and implemented some fixed for old versions (<200407070)
2047
2048 - callisto: MCalibrationHiLoCam can now be printed from its context
2049 menu, eg in the TBrowser
2050
2051 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2052 - 1.39 (MExtractTimeAndChargeSpline)
2053 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2054 This is important mainly for timing studies.
2055
2056 - callisto: Changed limits in MHCalibrationChargeCalc from
2057 - -100.125 to -98 (fgChargeHiGainFirst)
2058 - 1899.875 to 1902. (fgChargeHiGainLast)
2059 - -100.25 to -99 (fgChargeLoGainFirst)
2060 - 899.75 to 901. (fgChargeLoGainLast)
2061 Introduced new limits:
2062 - fgNumLoGainBlackoutLimit: 0.05
2063 - fgLoGainBlackoutLimit: 3.5
2064 - fgLoGainPickupLimit: 3.5
2065
2066 - callisto: The handling of automatic weights for the digital filter
2067 has been improved. There are now new calibration weights special
2068 for Monte Carlo calibrations.
2069
2070 - callisto: Updated Muon scale with latest results (1% difference
2071 for most data, 5% for Mar/Apr'05)
2072
2073 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2074 was saturated and the blackout-events in the low-gain exceed the
2075 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2076 This excludes those pixels which have a saturating high-gain
2077 channel, but the low-gain switch does not switch often enough
2078 to make the distribution reliable.
2079
2080 - callisto: fix a bug counting the number of saturated events. Up to now,
2081 the number of saturated slices was counted (which is one for a not too
2082 high number), but for some (pathological) pixels, many more slices
2083 saturated and produced wrong limits.
2084
2085 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2086 + MCalibrationRelTimeCam.CheckFitResults: Yes
2087 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2088 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2089 + MCalibrationRelTimeCam.CheckOscillations: Yes
2090
2091 - callisto: introduce max. number of events for intercalibration,
2092 the rest gets skipped. Default: 4096
2093 The calibration causes too many un-reliable pixels if more
2094 than about 5000 events are treated (@500 Hz) because of the
2095 mode hopping of the VCSels. However, in the past, some
2096 calibration runs have been taken (erroneously) with more
2097 than 5000 events, especially the intensity scans where
2098 a good precision is needed.
2099
2100 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2101 photo-electrons for the spline extractor by 1-2% (correctly).
2102
2103 - callisto: The intercalibration is now done using a full f-factor
2104 method instead of a simple update. This makes things slower but
2105 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2106 changes.
2107
2108 - callisto: MPedestalY3 now uses the same extraction range as the data
2109 as calculated by MPedestalY2
2110
2111 - callisto: A check of the fraction of allowed unsuitable (10%) and
2112 unreliable (30%) pixels has been addded when the conversion is
2113 calculated from interleaved events
2114
2115 - star: fixed a bug which caused MEffectiveOnTime containers not to
2116 be written. In the worst case they were skipped almost all, in the
2117 best case they were all ok. It depends on how often the new value
2118 was assigned just with an event which was skipped later by another
2119 task
2120
2121 - star: new histograms MHPointing and MHRate
2122
2123 - star: New tab (Currents) displaying the time evolution of the mean
2124 DC currents
2125
2126 - star: New tab (MeanRms) displaying the time volution of the mean
2127 Pedestal Rms
2128
2129 - star: Output now contains MReportStarguider
2130
2131 - star: Improved muon analysis. Due to the absense of a constant
2132 for the gaus fit for arc width and the fact that the arcwidth
2133 plot was a histogram instead of a profile the resulting psf
2134 became pedestal rms dependant
2135
2136 - ganymed: added new plot (MHPhi) for wobble mode as described in
2137 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2138
2139 - ganymed: corrects now (correctly?) for the misspointing in
2140 May/April 05
2141
2142 - ganymed: Two new default templates for ganymed.rc are avilable:
2143 ganymed_onoff.rc and ganymed_wobble.rc
2144
2145 - ganymed: The first version of MFMagicCuts has been released
2146
2147 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2148
2149 - ganymed, sponde: There are two new options to determin the number
2150 of bins for the signal region (NumBinsSignal) and the number of
2151 total bins (NumBinsTotal) in the MHThetaSq histogram
2152
2153 - ganymed: optimized palettes for MHDisp
2154
2155 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2156 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2157 sqrt(2) to large
2158
2159 - ganymed: The false source plot (MHDisp) is now based on Disp
2160 and a background model determined in the first loop is
2161 subtracted
2162
2163 - ganymed: MFMagicCuts are now available in the cvs. The correct
2164 solution for the disp ambiguity problem is now calculated using
2165 the third moment. The third moment cut therefor is skipped.
2166
2167 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2168 already determined by the third moment along the major axis and
2169 so its actual sign is aligned along the major axis of the shower.
2170
2171 - ganymed: If starguider data is available it is taken into account
2172 when calculating the source position. This is especially important
2173 for wobble data at high zenith angles and culmination data.
2174
2175 - ganymed: If available the starguider data is taken into account as
2176 good as it is possible without a starguider calibration. To switch
2177 it off add
2178 MPointingDevCalc.MaxAbsDev: -1
2179 to your ganymed.rc
2180
2181 - sponde: the zenith angle distribution is now weighted instead of
2182 choosen by default. This gurantees higher statistics in the highest
2183 and lowest energy bins. To switch this behaviour off use...
2184
2185 - sponde: now automatically displays the energy threshold
2186
2187
2188
2189 *** Version 0.9.3 (2005/06/03)
2190
2191 - general: MMcEvt now derived from MMcEvtBasic which should
2192 have no influence on compatibility with older camera files
2193
2194 - general: Implemented a new option to MReadReports which allows
2195 to force reading of the first event of some trees (eg. Drive-tree)
2196 before any other tree.
2197
2198 - general: Made a fix to MPointingPosCalc which assumes that the
2199 run-type is real-data if Process is called before ReInit, such
2200 that also the very first Drive-events in a run are treated
2201 correctly.
2202
2203 - shoplot now displays the filename in the title bar of the window
2204
2205 - merpp: new options: --auto-time-start --auto-time-stop which
2206 allow to cut updating with slow-control at the start- or
2207 (previousle --auto-time only allowed: and) stop-time of
2208 the run stored in the runheader.
2209
2210 - callisto: changed default of fgFallTimeHiGain in
2211 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2212 already set as default in callisto_Dec04Jan05.rc
2213
2214 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2215 now changes the filename for new weights automatically for
2216 cosmics, MC and for different calibration colors.
2217
2218 - callisto: a problem with the order of some code cause the
2219 name of the weights file in MPedestalY2 to be ignored.
2220 Wrongly the calibration_UV weights were used instead
2221 of the cosmics weights set in callisto.rc.
2222
2223 - callisto: should allow ct1 pulser data when the color is
2224 explicitly set also for pretty new runs
2225
2226 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2227 to introduce an additional scale factor (should be around 1)
2228 to adapt for slight deviations in different extractors from
2229 the MC calibration. For MC calibrations the scale factor
2230 is fixed to 1
2231
2232 - callisto: MFCosmics should handle very high signals a bit
2233 more accurate now
2234
2235 - callisto: when calculating the mean pedestal rms for different
2236 pixel sizes or sectors also kUnsuitableEvt is now taken into
2237 account - not only kUnsuitableRun
2238
2239 - callisto: '-raw' option is now the default
2240
2241 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2242 This has the advantage that mean values in the calibration (eg
2243 arrival times) are calculated more accuratly.
2244
2245 - callisto: In the resource file callisto_Dec04Jan05.rc
2246 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2247
2248 - callisto: new Hi-/Lo-Gain intercalibration constants
2249 hilocalib_sp1.root and hilocalib_sp1_mc.root
2250
2251 - callisto: changed default for MJPedestalY2.MaxEvents
2252 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2253
2254 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2255 has changed from 9.0 to 6.0. This is necessary to exclude two very
2256 ringing pixels in September which - when kept - destroy the image
2257 cleaning around them (Markus G.)
2258
2259 - callisto: (!) The Muon analysis of all data taken so far has
2260 suggested that different extractors give slightly different
2261 absolute results after calibration, due to there different
2262 handling of the calibration- and cosmics pulse shape. Although
2263 the over all calibration seems to be a bit to pesimistic (or
2264 the MC seems to be a little bit - 3-5% - too much attenuated).
2265 There for correction factors have been introduced which correct
2266 the calibration constants by
2267 0.956937799 for Digital Filter (callisto.rc)
2268 and
2269 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2270 calibration. The main advantage is, that both data types can
2271 be easily analysed together and compared to the same MC sample.
2272 The factors are choosen such, that the reference is now a
2273 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2274
2275 - star: fixed a bug which caused the first bin of the histograms
2276 vs time to disapear in PostProcess. This gave wrong results
2277 on the screen. The output and all following programs not
2278 directly accessing the histograms haven't been affected
2279
2280 - star, ganymed: Made sure that always the first Drive-tree event
2281 is read and Processed before the first data event was read.
2282
2283 - ganymed: implemented the possibility to replace the standard
2284 false source plot with a different one. For example: If
2285 you want to use a Disp based FS plot use the resource:
2286 NameHistFS: MHDisp
2287 For details about the requirements of these plots look
2288 at the corresponding classes
2289
2290 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2291 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2292 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2293 case MAlphaFitter is setup correctly. For On-Only optimization
2294 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2295 RunOn() instead of Run(). For energy estimation MJOptimize
2296 has been replaced by MJOptimizeEnergy
2297
2298 - sponde: The input MC spectrum can now be weighted to fake a
2299 different spectrum. This is done via MMcSpectrumWeight. For
2300 more details see the class description and sponde.rc
2301
2302 - sponde: The paremeter comparsion plots are not scaled by
2303 their entries anymore. Instead the MC plot is scaled by using
2304 the result spectrum of the analysis. If the input MC spectrum
2305 and the result spectrum has different slopes the absolut
2306 normalization is normally wrong.
2307
2308
2309
2310 *** Version 0.9.2 (2005/05/20)
2311
2312 - general: Changed the default paths for calibrated data and image
2313 files. (The implemented access to these files doesn't yet exist)
2314
2315 - general: support for MRunIter has been removed from the job classes
2316 (use the setter functions of MSeqeunce instead)
2317
2318 - general: ProcessFile has been renamed to Process in all job classes,
2319 because ProcessFile is missleading
2320
2321 - general: The storage of the palette in MHCamera is now possible
2322
2323 - general: new bits describing unsuitable and unreliable pixels have
2324 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2325 kDeadPedestalRms, kFluctuatingArrivalTimes
2326
2327 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2328 versions newer than V200404070
2329
2330 - general: support for cc file versions newer than V200504130. Added
2331 support for active loads (MCameraActiveLoad) and central pixel
2332 (MCameraCentralPixel)
2333
2334 - general: added new histograms for image parameters versus size
2335 (MHVsSize)
2336
2337 - general: The eventloop now automatically calls PrintStatistics
2338
2339 - Status Display: Improved support for printing:
2340 + A default can now be set in .rootrc (for more details see
2341 MStatusDisplay::PrintPS)
2342 + A print dialog is opened so that printer and command line
2343 can be canged
2344
2345 - showlog: improved such that it handles different verbosity levels
2346 more accurate now. This mean you can suppress output when
2347 using showlog.
2348
2349 - showplot: improved
2350 + The new graphics formats have been implemented
2351 (pdf, svg, png, jpg and xpm)
2352 + Implemented an interface for printing. Because you can change
2353 the printing command from the command line you can use all
2354 the nice postscript tool. To print a booklet for example call:
2355 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2356 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2357 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2358
2359 - callisto: fixed a bug in the recognition of the calibration bit
2360 pattern. Concerns only intensity calibration. (The strength of the
2361 intensity has been updated in some cases)
2362
2363 - callisto: add a filter against PIN Diode events when running over
2364 calibration runs since some of the recent calibration runs have
2365 been taken with Pin Diode.
2366
2367 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2368 39943, 44833 in the calibration (MCalibColorSet)
2369
2370 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2371 been set to 1e-18 in callisto_Dec04_Jan05.rc
2372
2373 - callisto: in callisto_Dec04Jan05.rc: set value for
2374 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2375 statistics for the calculation of the mean pulse time
2376 of the cosmisc
2377
2378 - callisto: the charge limit in the calibration has been raised
2379 from 2.5 to 4.5
2380
2381 - callisto: new setup read from callisto.rc
2382 + MCalibCalcFromPast.fNumEventsDump
2383 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2384 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2385
2386 - callisto: MExtractTimeAndChargeSpline extractor:
2387 + The integration ranges were shifted by 0.2 FADC slices to the right.
2388 + unreliable handling of floating point values caused different
2389 results on different platform or with different compiler options:
2390 The new algorithm is numerically exact and more accurate because
2391 it doesn't calculate the integration position by multiple times
2392 adding the step-size (which results in numerical uncertanties
2393 exspecially if multiplied with large numbers)
2394 + A lot of fixes have been introduced which effects integrating the
2395 spline at the edges of the valid range. In this case any memory
2396 was randomly accessed. This behaviour can be tested replacing
2397 all MArrayF by TArrayF which perform a range check (but of course
2398 they are a lot slower)
2399 ! No result obtained with the Spline before can be trusted! Due to
2400 random memory access it might by completely random!
2401
2402 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2403 + extraction range in the high gain to 4.
2404 + weights file to cosmics_weights46.dat
2405
2406 - callisto:
2407 + introduce the check for fluctuating arrival times.
2408 + set charge limit to from 2.5 to 4.5
2409 + introduce asymmetric exclusion due to "deviating number of phes":
2410 Default: -9.0 +4.5
2411 + make deviating number of phes unsuitable (see David's findings).
2412
2413 - callisto: fixed the display of unsuitable pixels. The old change
2414 to a real profile in MHCamera broke it.
2415
2416 - callisto: The cosmics filter is used in MJCalibration now
2417 independant of the pulser color (formaly it was used only for
2418 CT1-pulser data). The threshold of number of max empty pixels
2419 has been raised from 2% to 5% in MJCalibration. The maximum
2420 fraction of rejected event is 50% otherwise the calibration has
2421 failed. The filter now ignores unsuitable pixels.
2422 Setup the filter from callisto.rc using "ContCosmics"
2423 (see MFCosmics::ReadEnv)
2424
2425 - callisto: changed default for fgOffsetFromLogain back
2426 from -2.8 to -1.8 in digital filter.
2427
2428 - callisto: for the common extractors
2429 + MExtractFixedWindow
2430 * MExtractTimeAndChargeSlidingWindow
2431 * MExtractTimeAndChargeSpline
2432 * MExtractTimeAndChargeDigitalFilter
2433 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2434 and fResolutionPerPheLoGain
2435
2436 - callisto: Updated the hi-/lo-gain intercalibration constants
2437 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2438 hilocalib_df6.root
2439
2440 - callisto: The default lo-gain extraction window for the
2441 MExtractTimeAndChargeSlidingWindow extractor has been increased
2442 from 6 to 8 to take the stretch of the pusle into account
2443
2444 - callisto (!!!): fixed an important bug in the setting of the
2445 incoming pedestal pointer to the signal extractor extracting
2446 pedestals. This bug caused the pedestals not to be subtracted
2447 correctly in the calibration afterwards. The effect was about 10%
2448 too high conversion factors for the digital filter and the spline
2449 and more than 40% for the sliding window.
2450 The bug existed since end of February! (Markus G.)
2451
2452 - star: added muon support to star. A new tab "MHMuonPar" is
2453 displayed. The lower right plot is an estimate of the point spread
2454 function. A reference value is displayed. To get the real PSF
2455 you must compare with MC. The setup for the muon analysis
2456 is done in star.rc. More informations can be found in
2457 MHSingleMuon and MHCalibParCalc
2458
2459 - star: The weather data is now displayed in star
2460
2461 - star: MEventRateCalc handles the calculation of the event rate more
2462 accurate now in case of the start of a new run inside a sequence
2463
2464 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2465 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2466 changed only minimally
2467
2468 - ganymed: (MJCut and MJOptimize) now displayes the number of
2469 excess events versus size. The energy estimation is done in
2470 MJSpectrum (sponde)
2471
2472 - ganymed: got support for using other variables than Alpha, eg. Theta.
2473 Therefor you need a class deriving from MHAlpha which supports
2474 this variable (one is already existing: MHTheta, which is now the
2475 default in ganymed). It is setup through ganymed.rc
2476
2477 - added a full featured spectrum program (sponde) which reads
2478 ganymed output and monte carlos and compiles a spectrum
2479
2480
2481
2482 *** Version 0.9.1 (2005/04/14)
2483
2484 - Fix bug on the arrival time reconstruction when using Digital
2485 Filter (in some marginal cases (10%) times were reconstructed shifted
2486 by 0.2 slices)
2487
2488 - all executables now return 2 where in previous versions -1 has
2489 been returned (gave problems with shell-scripts)
2490
2491 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2492 also done with a intercalibration input file
2493
2494 - a bug in the time fine adjustment of the digital filter has been fixed
2495
2496 - a lot of small fixes to calling TPad::Divide with a margin==0
2497
2498 - MStatusDisplay now shows the memory usage
2499
2500 - added a memory leak statistic after the eventloop
2501
2502 - MHadronness replaced by MParameterD
2503
2504 - MEnergyEst replaced by MParameterD
2505
2506 - wobble mode can now be switched on from the data-set
2507
2508 - switched on bad pixel detection for a pedestal level
2509 which is more than 5 times the variance
2510
2511 - Fixed default paths to be correct for the new data center
2512
2513 - Fixed handling of drive data. The pointing position in now
2514 copied to MPointingPos inside star for real and MC events
2515
2516 - made sure, that the sequences in a dataset are sorted by
2517 their number to ensure the correct synchronization
2518
2519 - added all resource files necessary to handle spline extraction
2520 of signal for the late 2004 and the early 2005 data
2521
2522 - update the reference lines for the december data
2523
2524 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2525 This is important for the Dec. and Jan. data where the calibration
2526 pulse position changes much.
2527
2528 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2529 filter. This corrects only an defective extraction of the MC at
2530 low-gain signals lower than 90 phes.
2531
2532 - fixed some slowdown in calibrating data with interleaved events from
2533 Jan and Dec. As a workaround made the pretty palette the default.
2534 The inverse Deep Blue Sea has a bug which slows down long calibration
2535 runs a lot.
2536
2537 - implemented new values from new starguider report as defined
2538 in TDAS00-07 V7.1 (eg SkyBrighness)
2539
2540 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2541 in starguider report (If you merpp the same reports with this version
2542 you'll get the correct units (arcmin) but a different result
2543 than with old versions (wrong units))
2544
2545 - Now the status display can also write PNG, JPEG and XPM (other file
2546 formats are still unsupported by root)
2547
2548 - added a lot of scripts and macros in directory datacenter used
2549 for automatic processing
2550
2551
2552
2553 *** Version 0.9 (2005/03/23)
2554
2555 - Calibration is now done autmatically into photo-electrons like
2556 decided by the Collaboration Board
2557
2558 - Reference lines in the display can be read from resource file
2559
2560 - Interlaced calibration events can be handled by callisto
2561
2562 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2563 and applied in callisto.
2564
2565 - class MJCalibTest can be called by callisto
2566
2567 - callisto can now run with three data types: rawdata, rootdata, MC
2568
2569 - added two classes mreport/MReportStarguider.cc and
2570 mreport/MReportStarguider.h for implementing starguider-data
2571
2572 - the output of merpp-update now contains starguider information:
2573 MReportStarguider and MTimeStarguider
2574
2575 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2576 values were lower than they should. This was more visible for high
2577 energy (Size) events.
2578
2579 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2580
2581 - added a new loop to callisto to support the correct extraction of
2582 the pedestal and pedestal rms through the signal extractor
2583
2584 - added class to perform fourier tranformation of a hexagonal structure
2585 (MHexagonalFT)
2586
2587 - added class to perform fourier tranformation of a hexagonal structure
2588 in a tasklist (MHexagonalFTCalc) example: hft.C
2589
2590 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2591 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2592 small pixels, example: extendcam.C
2593
2594 - added possibility to write data to memory (TTree) using MWriteRootFile
2595
2596 - added possibility to read a TTree stored only in memory by MReadTree
2597
2598 - new classes to deal with the interleaved calibration events:
2599 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2600
2601 - implemented filters to callisto to skip calibration events
2602
2603 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2604 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2605 the slices by statistics
2606 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2607 signal extractor without randomization
2608 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2609 with the signal extractor with randomization (extraction window is
2610 randomly fixed)
2611 The three kind of pedestal is not yet implemented (for speed reasons) as
2612 long as nobody really needs it:
2613 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2614 extracted with the signal extractor with randomization
2615
2616 - callisto now finds the pulse position in the data automatically
2617
2618 - implemented data reduction in calibrated data by reducing the precision
2619 of the stored floating point values (pedestal, rms and signal) to
2620 roughly 0.5%
2621
2622 - fixed showplot to make file format conversion (eg. converting a
2623 status display stored in a root file into a postscript file) in
2624 batch mode possible:
2625 showplot -b --save-as-ps[=outfile.ps] infile.root
2626
2627 - Allow class names as part of filter rules, eg
2628 (MFSupercuts) && (MHillas.fSize>100)
2629
2630 - fixed a lot of stuff to allow all programs to process MonteCarlo
2631 camera files.
2632
2633 - enhanced possibility to debug reading of resource file
2634
2635 - MDataChain should handle priorities of operator more
2636 accurate now
2637
2638 - completely revised the container in which the signal is stored
2639 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2640 * the new implementation is faster and
2641 * needs less storage space
2642
2643 - FIRST version which can process Monte Carlos through the
2644 whole chain of programs (callisto, star, etc)
2645
2646 - implemented new image parameters for the border length of
2647 the shower image (MNewImagePar2)
2648
2649 - implemented wobble-mode in ganymed
2650
2651 - new class (MJOptimize) taking care of all optimization processes
2652
2653
2654
2655 *** Version 0.8.6 (2004/10/05)
2656
2657 - New combined signal and time extractor
2658 MExtractTimeAndChargeDigitalFilter
2659
2660 - The Report for the trigger section in the CC run summary has been
2661 updated, and now the IPRs (Individual Pixel Rates) are available.
2662
2663 - new macros for database interaction: filldotrun.C, filldotrbk.C
2664
2665 - added new program which can convert colored output which was redirected
2666 into a file back into colored text (for example to display it with
2667 more): showlog
2668
2669 - added new program to display an MStatusArray of plots (stored with
2670 MStatusDisplay) from a file: showplot
2671
2672 - Added support for Sequences (MSequence). Sequences are blocks of run
2673 files containing the same calibration and belonging to the same
2674 source
2675
2676 - Added a new task (MTaskEnv) which can be used in setup files to switch
2677 between different tasks (for example to choose a signal extractor)
2678
2679 - Implemented automatic file splitting in MWriteRootFile
2680
2681 - After image cleaning an island index is assigned to all used pixels.
2682 The index corresponds to the order of the islands in size.
2683
2684 - added a cleaning which takes signal height _and_ arrival time into
2685 account: probability cleaning (for more details see MImgCleanStd)
2686
2687 - added a cleaning which takes takes the absolute number of photons
2688 times the area ratio as cleaning level
2689 (for more details see MImgCleanStd)
2690
2691 - Changed calculation of image parameters such, that it can be done
2692 for all used pixels or the pixels with a defined island index only
2693
2694 - implemented new image parameters displaying the number of islands,
2695 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2696
2697 - event display in executable changed to support also calibrated files
2698 (done with MJCalibrateSignal)
2699
2700 - added program doing the calibration and the signal extraction
2701 and signal calibration: callisto Most part of the setup is done
2702 by a resource file: callisto.rc
2703
2704 - implemented support for pixels with negative IDs (Raw file format
2705 version 4)
2706
2707 - implemented an new option in merpp (--auto-time) to get the time
2708 range for cc and/or caco data from the run header of the raw data
2709
2710 - New star-program (star and MJStar). Taking calibrated data from
2711 callisto/MJCalibrateSignal as input. The setup is done through
2712 a resource file: star.rc
2713
2714 - Added possibility to setup the eventloop in the mars-executable
2715 Camera Display by a resource file: mars.rc
2716
2717 - The the mars-executable Camera Display can now also read
2718 calibrated data files written by callisto/MJCalibrateSignal
2719
2720 - Added a new class which can calculate the source position in
2721 the camera from a pointing model known to be correct and
2722 the pointing model used for observations (MSrcPosFromModel)
2723
2724 - added a new version of the class calculating the effective on-time
2725 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2726 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2727 MHTimeDiffTheta.
2728
2729 - added the possibility to count how often a signal is above (or
2730 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2731 can replace MHTriggerLvl0)
2732
2733 - added ore convinient ways to set the axis-titles of your histograms
2734 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2735 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2736
2737
2738
2739 *** Version 0.8.5 (2004/08/06)
2740
2741 - new Signal Extractors: MExtractFixedWindowSpline
2742 and MExtractAmplitudeSpline
2743
2744 - implementes interleave in merpp to be able to merpp parts of a file
2745
2746 - implemented force-functionality to merpp
2747
2748 - star display to display star catalogs (MAstroCatalog)
2749
2750 - star display to 'mirror' stars to the camera (MAstroCamera)
2751
2752 - implemented a new cleaning option which allows cleaning scaled with
2753 the real ratio of the rms depending on the pixel size, not only the
2754 square root of the pixelsize (MImgCleanStd, MCameraData)
2755
2756 - removed obsolete MBlind* classes
2757
2758 - Signal extractor taking the AB flag into account implemented (this makes
2759 an odd number of slices for signal extraction possible
2760 (MExtractSignalABcorr)
2761
2762 - implemented a class extracting the pedestal from the raw-data (events)
2763 itself using empty lo-gain (MpedCalcFromLoGain)
2764
2765 - Added mean values to MPedPhotCam
2766
2767 - Added Makefile for Darwin (this OS is NOT officially supported!)
2768
2769
2770
2771 *** Version 0.8.4 (2004/04/19)
2772
2773 - new fast arrival time extractor using cubic splines:
2774 MExtractTimeFastSpline
2775
2776 - implementes multi-argument support in MDataChain
2777 ("pow(a, b)")
2778
2779 - implemented double reference support in MDataChain
2780 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2781
2782 - added support in MF for expressiond like
2783 "MHillas.fWidth<2*<MHillas.fLength"
2784
2785 - MDataChain is now able to support variables like [0], [1], ...
2786 which can be used in fit functions as parameters. The interface
2787 is implemented through the new virtual function
2788 MParContainer::SetVariables
2789
2790 - added new class MArrivalTimeCam/MArrivalTimePix:
2791 Storage containers to hold the ArrivalTime of the camera/pixel
2792
2793 - added new classes for the calibration of relative arrival times:
2794 MCalibrationRelTimePix and MCalibrationRelTimeCam
2795
2796 - added new classes to extract the signal of the blind pixel and the
2797 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2798
2799 - added new classes for the bad-pixels treatment (MBadPixels*)
2800 which are more powerfull than the old ones (MBlindPixel*)
2801 and will replace them.
2802
2803 - added filter against cosmics: MFCosmics
2804
2805 - added new class MArrivalTimeCalc2:
2806 Calculates the arrival time as the signal weighted mean of the time
2807 slices in the maximum window
2808
2809 - added a new macro call pointspreadfucntion.C that fits with a 2D
2810 gaussian the DC spot for an star. It gives you the RMS of
2811 the PSF and the center of the star, very useful for misspointing
2812 studies.
2813
2814 - added support for multi-telescope camera files. Added classes
2815 MStereoCalc and MStereoPar, classes to calculate and store shower
2816 parameters calculated from the data of two telescopes, for the MC
2817 studies regarding the MAGIC clone.
2818
2819 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2820 MC data calibrated in photons instead of ADC counts.
2821
2822 - added three macros to show the calibration and analysis chain of
2823 MC data. The macro starmc.C does both calibration and analysis, producing
2824 an output containing Hillas parameters for each event. The macro
2825 mccalibrate.C does just the calibration and writes out a file containing
2826 pixel information in photons instead of FADC data. The macro starmc2.C
2827 reads in such a file and produces an output with Hillas parameters.
2828
2829 - added MPedPhotCalc to compute pedestals in units of photons, see
2830 macro pedphotcalc.C
2831
2832 - added all class to perform the calibration, see macro calibration.C
2833
2834 - added class MFFT to perform Fast Fourier Transforms
2835
2836 - added class MSimulatedAnnealing to perform simulated annealing
2837 minimizations
2838
2839 - added new macro bootcampstandardanalysis.C which holds the skeleton
2840 of the analysis chain discussed in the december bootcamp.
2841
2842 - added support for DAQ raw data file format V2
2843
2844 - implemented an arbitrary time stamp for the events from raw-data
2845 files with file version<3. It is calculated from the run number,
2846 the date of start and the FADC clock tick from the first module
2847
2848 - implemented the correct decoding of the event time-stamp
2849 coming from the DAQ for raw-data files with file-version>2
2850
2851 - added a new classes storing the pedestals in units of photons:
2852 MPedPhotPix, MPedPhotCam
2853
2854 - added support for DC current files from the camera control
2855
2856 - added support for start- and stop-time when merpping report files
2857
2858 - added MReportCC storing the weather data from the CC-REPORT
2859
2860 - added class to fill trainings and test matrices (MTFillMatrix)
2861
2862 - added a filter performing a software trigger (MFSoftwareTrigger)
2863
2864 - Added classes to perform parts of the standard analysis (Jobs):
2865 + MJPedestals
2866 + MJCalibration
2867 + MJExtractSignal
2868 Note: All of them are preliminary!
2869
2870 - Added Iterator to iterate over files giving only the run-number
2871
2872 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2873 the evolution of a sector vs time
2874
2875
2876
2877 *** Version 0.8.3 (2003/12/05)
2878
2879 - adapted Random Forest classes to allow the use with MC
2880 multi-telescope files which can be produced with the coming
2881 camera version 0.7.
2882
2883 - added classes to read and interprete central control report files
2884 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2885
2886 - enhanced merpp (the executable) to support .raw and .rep files.
2887
2888 - added classes for light calibration (MCalibration* and
2889 MHCalibration*) by Markus Gaug. Further work has to be and will
2890 be done soon.
2891
2892 - Added a preliminary 'synchronizer' (MReadReports) which will
2893 replace MReadMarsFile as soon as it is finished.
2894
2895 - Added a tutorial macro demonstrating how report files are merpped
2896 and how they can be read from the root file in the correct order
2897 of time (readrep.C)
2898
2899 - Added a generalized histogram (similar to MH3) called MVsTime
2900 which allows to plot variables (or rules - MDataChain - of
2901 variables) vs time. For an example have a look at tempvstime.C.
2902
2903 - Changed the name of the event trees:
2904 + Events --> Events
2905 + PedEvents --> Pedestals
2906 + CalEvents --> Calibration
2907
2908 - changed name of MTime in the event trees from MRawEvtTime to MTime
2909
2910 - added displaying the sector indices to the mars event display
2911
2912 - Magic Online Analysis (MOnA) implemented in a first version
2913 (see mona.cc, MOnlineDump and MOnlineDisplay)
2914
2915 - added classes to calculate event rate
2916 (preliminary: MEventRateCalc, MEventRate)
2917
2918 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2919
2920 - added classes dealing with the telescope pointing position (MPointing*)
2921
2922 - implemented the 'final' Mars time stamp based on some experiences with
2923 the new 'Synchonizer'
2924
2925
2926
2927 *** Version 0.8.2 (2003/11/10)
2928
2929 - accelerated standard analysis by a factor of 6-8 ...
2930 + doing precalculations in MGeomCam for the pixel area ratio
2931 + creating a look up table for the single pixels in MCerPhotEvt
2932
2933 - added task to calculates weights in case you want to 'change'
2934 the energy spectrum of a monte carlo file
2935 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2936
2937 - added a new executable star which implements the
2938 star.C macro as precompiled executable. Currently a flexible
2939 setup is not possible, but a 'input card' setup will follow.
2940
2941 - Starting to implement Multi-Telescope-Support based on the
2942 upcomming camera version 0.7. The base for a general support
2943 is implemented and the star-functionality is proven to work.
2944
2945 - Replaced Event-Display in and Camera-Display in the Mars GUI
2946 executable by a more convinient display base on MStatusDisplay.
2947
2948 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2949
2950
2951
2952 *** Version 0.8.1 (2003/10/20)
2953
2954 - added signal subtraction for pure on data by means of fitting
2955 the background in the off region or by performing a combined
2956 signal/background fit. Provides necessary histograms for
2957 obtaining energy spectra and a light curve.
2958
2959 - added classes to perform and study the selection of the
2960 2nd Level Trigger on MC data (example in triglvl2.C macro)
2961
2962 - added pedestal calculation
2963
2964 - implemented "democratic cleaning" (tail cut value proportional
2965 to pixel area) according to Wolfgang's suggestion.
2966
2967 - added Sigmabar treatment (calculation and basic histogramming)
2968
2969 - added basic routines to apply padding
2970
2971 - added first implementation of MARS-based source visibility plotter
2972 (needs to be linked against slalib, preliminary version)
2973
2974 - enhanced functionality of data chains: random numbers, conversion
2975 functions and access to MHMatrix objects
2976
2977 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2978 numbers under certain circumstances (runs with 0 events included)
2979
2980 - fixed a bug in the general filter MF (didn't work on some systems
2981 at all)
2982
2983 - fixed a bug in chaining files, which caused the analysis to crash or
2984 ignore files
2985
2986 - implemented more geometry classes describing the parameters used
2987 to simulate the PMT camera
2988
2989 - added new Monte Carlo classes containing the setup of the different
2990 programs in the MC chain.
2991
2992 - added a (preliminary) general task to evaluate chi-square of a given
2993 parameter in an eventloop.
2994
2995 - first implementation of a container describing the observatory
2996 location (Long, Lat, etc)
2997
2998 - added Random Forest - method for g/h-separation
2999
3000 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3001 (this means, that it is compiling, but not yet fully tested)
3002
3003 - added a new status display which can show the present status
3004 of histograms while an eventloop is running (MStatusDisplay,
3005 an example can be found at status.C)
3006
3007 - reorganized directories:
3008 classes describing the image --> mimage
3009 classes containing Monte Carlo Histograms --> mhistmc
3010 classes for Random Forest method --> mranforest
3011
3012 - added (event-)weights to fill histograms
3013
3014 - colors in logging output to screen
3015
3016 - changes to the Image Parameter declaration:
3017 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3018 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3019 + MHillasExt now derives from MParContainer instead of MHillas
3020 --> Files written with the old definition are more or less unreadable
3021
3022 - reading of reflector files
3023
3024 - display data from reflector files in the camera
3025
3026 - implemented currents (and display them in the camera)
3027
3028 - logarithmic scale in camera
3029
3030 - added class to iterate through directory contents (MDirIter)
3031
3032
3033
3034 *** Version 0.8 (2002/11/18)
3035
3036 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3037
3038 - corrected 48(!) wrong entries in the Next Neighbor table of the
3039 Magic Camera (all in the inner part of the outer ring, mostly
3040 missing a single NN)
3041
3042 - Fixed a bug in the table describing the Next Neighbours of the
3043 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3044 have any neighbour)
3045
3046 - changed trigrate.C: now it calculates the pure NSB triggers from
3047 a camera file (generated with no showers), so there is no need
3048 to introduce them by hand in the BgR array (for more details
3049 please ask Abelardo)
3050
3051 - added MHHadronness (and MHadronness) as a general facility to evaluate
3052 the quality of a gamma-hadron seperation method
3053
3054 - changed MWriteAsciiFile to accept rules (MDataChain)
3055
3056 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3057 must be replaced by calles to MWriteAsciiFile::AddColumn and
3058 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3059 changed.
3060
3061 - Implemented generalized event-matrices (one row per event)
3062 (MHMatrix)
3063
3064 - implemented the one dimensional composite probabilities
3065 (MHCompProb, MCompProbCalc, comprob.C)
3066
3067 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3068 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3069
3070 - Added a camera display displaying the pixel numbers to the
3071 event display gui.
3072
3073 - Added Monte Carlo Informations to event display gui
3074
3075 - Changed the camera display to display the pixel numbering
3076
3077 - Added three buttons to the camera display to change the palette
3078
3079 - Added the number of used and core pixels after image cleaning
3080 to MHillas
3081
3082 - Changed the algorithm used in MHillas according to TDAS 02-03
3083
3084 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3085
3086 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3087
3088 - Added fCosDeltaAlpha to MHillasSrc
3089
3090 - The numbers of photons used to calculate fConc and fConc1 in
3091 MHillasExt are now scaled with the pixel size, so that one get
3092 a four times smaller value for the bigger pixels in the outer ring.
3093
3094 - added new task to smooth the camera contents (MCameraSmooth)
3095
3096 - added possibility to use interpolated pixel values for blind pixels
3097 instead of removing it completely from the analysis
3098
3099 - Implemented the possibility to save the whole eventloop with
3100 its setup to a file. This information can be read and from
3101 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3102 and MEvtLoop::MakeMacro. If you find something not working, please
3103 report - this stuff is still in a beta phase.
3104
3105 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3106 file having crab starfield, but also for all following files - fixed
3107
3108 - MTaskList::PrintStatistics can now be instructud to print also the
3109 title, too: use PrintStatistics(0, kTRUE)
3110
3111 - Changed the image cleaning so that pixels with to many 'used'
3112 neighbors are left used (to get rid of 'holes' in events)
3113
3114 - Introduced more output to the camera displays
3115
3116 - Added an array of histograms (eg one hist per run), MHArray
3117
3118 - Added a _preliminary_ version of the reader for CT1 PreProc files
3119 (MCT1ReadPreProc)
3120
3121 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3122 (thanks to Raquel)
3123
3124 - added the first energy estimator (MEnergyEstParam, estimate.C,
3125 estfit.C) using a parametrization
3126
3127 - Added some new Monte Carlo paremeter containers used to store
3128 setup information from the MC chain (MMcConfigRunHeader,
3129 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3130
3131
3132
3133 *** Version 0.7 (2002/04/30)
3134
3135 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3136 the pedestal mean value was saved incorrectly. For files from
3137 this versions we substract 0.5 from the pedestal mean.
3138 WARNING: This may effect your results, so don't wonder...
3139
3140 - First implementation of an algorithm using only triggered events
3141 for the collection area calculation
3142
3143 - Ascii Output can now also be used for parameter containers which
3144 doesn't overload MParCointainer::AsciiWrite
3145
3146 - The Ascii Output is now also capable of writing single data members
3147 of one container
3148
3149 - You are now able to change the order of the values written to the
3150 ascii file
3151
3152 - You can now specify a conversion factor for each data member written
3153 to an ascii file. This may be usefull to change the units of the
3154 data member (eg. degrees instead of millimeters in case of the
3155 hillas parameters)
3156
3157 - Replaced old MHillas by a new structure which allows you to extend
3158 the parameters stored in MHillas very easily:
3159 see MHillas and MHillasExt
3160
3161 - Added classes to handle source dependancy of image parameters:
3162 see MHillasSrc
3163
3164 - Added container (MBinning) to have a standard input for the binning
3165 in different histograms (eg. the Energy bins should be the same in
3166 all histograms)
3167
3168 - Changed Hillas histograms from mm to deg
3169
3170 - Added the flexible binning to the hillas histograms
3171
3172 - Added a filter for the alpha parameter (MFAlpha)
3173
3174 - It is now possible to write single data members of a class object to
3175 an output stream instead of the whole container only
3176
3177 - Added a generalized filter for a data member:
3178 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3179
3180 - Added a generalized Filter parser for more difficult filter rules
3181 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3182
3183 - Added new Monte Carlo histograms:
3184 MHMcEnergyImpact and MHMcEfficiency
3185
3186 - Added many new histograms needed for the flux calculation.
3187
3188 - Added a generalized histograms which can fill and show up to three
3189 data members in either a one-, two- or three-dimensional histogram, eg:
3190 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3191
3192 - Added:
3193 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3194 * calculation of <Theta> as a function of time (MHThetabarTime)
3195 they are needed in the flux calculation in
3196 order to select for a given bin in Theta (or time) the appropriate
3197 effective collection area, which is assumed to be given as a function
3198 of Theta and the true energy
3199
3200 - Added calculation of the migration matrix in the energy
3201 (MHMcEnergyMigration):
3202 the migration matrix describes the migration from the true (E_true)
3203 to the estimated energy (E_est); it is needed to determine the
3204 distribution of E_true from the measured distribution of E_est
3205 by unfolding
3206
3207 - changed the color palette in the camera display to DeapSea.
3208
3209
3210
3211 *** Version 0.6 (2002/01/15)
3212
3213 - Introduce the option of disable pixels (MBlindPixels and
3214 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3215 able to deal with Star Field NSB.
3216
3217 - Fixed a bug in the pedestals substraction
3218
3219 - Introduced verbosity levels
3220
3221 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3222
3223 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3224 work correctly (thanks to Abelardo)
3225
3226 - Introduced correct treatment of the diffuse Night Sky Background
3227 and NSB (MMcPedestalNSB)
3228
3229 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3230
3231 - Introduced MMcRunHeaders which contains monte carlo run informations
3232
3233 - Added a 'Print'-Task (MPrint) which calls the Print function
3234 of a parameter container for each event
3235
3236 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3237
3238 - changes to be more efficient with root 3.02/06
3239
3240 - root 3.02/06 fixes:
3241 + the memory leak when reading MRawEvtData
3242 + loosing more time than necessary to update the progress bar
3243
3244 - MWriteAsciiFile is now capable of writing more than one container
3245 in a line. For example: To be able to write Monte Carlo and
3246 Hillas values (energy and alpha) in one line.
3247
3248
3249
3250 *** Version 0.5 (2001/11/06)
3251
3252 - Added new GUI functionality (Analysis)
3253
3254 - Added a camera display to be able to display events in the camera
3255 together with the calculated hillas ellipse
3256
3257 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3258 object at any state of the analysis, so that the output are several
3259 states
3260
3261 - Fixed a bug in the collection area error calculation
3262 (Thanks to Ciro and Abelardo)
3263
3264 - Fixed a bug which causes merpp to crash in some environments
3265
3266 - Implemented auto enabling scheme for Branches to speed up reading
3267 a lot (see MReadTree and MTask)
3268
3269 - Fixed a bug in the Histogram classes which caused histograms to
3270 be written to a file by MWriteRootFile without request
3271
3272 - changed the object I/O from the old stylish root I/O to the new
3273 'auto evolution scheme' This was done only for classes which are not
3274 yet used in Monte Carlo files, so that these files are still readable.
3275
3276 - Added support for a progress bar in MEvtLoop and MReadTree
3277 (see the Analysis Window in Mars for an example)
3278
3279 - Fixed a bug in the package creation which disturbed the conversion
3280 between a mars version unpacked from a tar file and the repository.
3281
3282 - Changed the code to writer merpped (converted into root format)
3283 raw files, to get faster (around 10%)
3284
3285
3286
3287 *** Version 0.4 (2001/09/20)
3288
3289 - This release is made to compile on a root version >= 3.00
3290
3291 - Fixed a bug which causes MReadTree to read the first file only
3292
3293 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3294
3295 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3296
3297 - Added a task to write several container to a root file (MWriteRootFile)
3298
3299 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3300
3301 - Added calculation of the collection area (MMcCollectionAreaCalc)
3302
3303 - fixed some bugs in the Hillas calculation
3304
3305 - added filters to be able to control the task execution dependent on
3306 a parameter (for example: the number of level 1 triggers in a MC-file)
3307
3308
3309
3310 *** Version 0.3 (2001/04/23)
3311
3312 - Many demo macros added
3313
3314 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3315
3316 - Hillas Calculation added
3317
3318 - Standard image cleaning available
3319
3320 - MReadTree is now able to handle more than one file
3321 (Remark: of the same structure)
3322
3323 - Now we are able to display events in a first version of the
3324 Camera event display. To do this we must run the macro
3325 "macros/readCT1.C" to read data from CT1.
3326
3327
3328
3329 *** Version 0.2 (2001/01/24)
3330
3331 - First Implementation of a Gui to read the raw data. Start the
3332 gui with the command mars.
3333
3334
3335
3336 *** Version 0.1 (2000/12/20)
3337
3338 - First official release 0.1
3339
3340 - Changes:
3341
3342 + changed calling style of MRawPixelIterator from do...while to
3343 while-loop
Note: See TracBrowser for help on using the repository browser.