source: trunk/Mars/NEWS@ 9825

Last change on this file since 9825 was 9822, checked in by tbretz, 14 years ago
The resolution in trainenergy.C is not displayed as resolution squared anymore.
File size: 138.7 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * On some systems (version of make?) the __LINUX__ definition was not set
8 when compiling. This lead to MTime(-1) not working properly. Fixed.
9
10 * The status display is now able to write a plain root file which means
11 that the MStatusArray container is omitted and the TCanvas are written
12 to the file directly. This allows to write files which are accessible
13 from a plain root (without MARS) if no MARS objects are contained
14 in the TCanvas'. In turn the reading of files which contains
15 objects and TCanvas' but no MStatusArray object has been improved.
16
17 * MMcEvt.fPhi and MMcEvt.fTheta have been moved to its base class
18 MMcEvtBasic. Consequently, the direction of the primary shower
19 is not lost in the OriginalMC tree anymore
20
21 ;ceres:
22
23 * Allow for individual mirrors with parabolic shape (for details see
24 MReflector::ReadFile)
25
26 * As an additional output artificial star-files are written. They
27 contain star output compatible output based on the signal as
28 in the artificial callisto output files.
29
30 * The trigger channel which issued the trigger is now stored in
31 MRawEvtHeader::fNumTriggerLvl1
32
33 * The number of photons in the calibration signal is now distributed
34 by a possonian instead of a Gauss.
35
36 * implemented new file-naming scheme (corsika run-number is new
37 tranfered to the ceres output as file-number). Therefore a new option
38 has been implemented to set an artificial run-number:
39 ---run-number=12345
40
41 * The baseline, the baseline noise and the gain (multiplicator to the
42 pulse) are now accessible from the outside. The new values are:
43 MSimCamera.DefaultOffset
44 MSimCamera.DefaultNoise
45 MSimCamera.DefaultGain
46
47 ;star:
48
49 * The time constraint in the image cleaning is now scaled with the
50 pixel distance. Consequently, the value given is not absolute in
51 ns anymore, but in ns/deg. This means that the values for MAGIC
52 have to be scaled by a factor of 10.
53
54 ;trainenergy.C:
55
56 * The rsolution is not displayed anymore as resolution squared
57
58
59
60== Version 2.4 (2009/12/23) ==
61
62 ;general:
63
64 * Added a new palette "temp" to MH::SetPalette which should resample
65 a temperature
66
67 * Added consistency check for two consecutive runs
68
69 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
70 has been disconnected and the L1 (L1TPU) has directly been connected
71 to another bit in the trigger pattern. This has been fixed by an
72 update of the decoding. Both bits are now or'ed together.
73
74 * Added a new camera layout MGeomCamFact which is the "four rectangular
75 pixels ordered in a hexagonal geometry" layout
76
77 * All programs now store the command line as TNamed "CommandLine"
78
79 * the environment variable OSTYPE should now be obsolete. Instead
80 the output of "uname -s" converted to lower cases is used
81
82 * The Makefiles should now detect the OSTYPE automatically using
83 uname. This should make the setting of OSTYPE obsolete
84
85 ;showplot:
86
87 * If a file without a MStatusArray is opened all object (not just
88 canvases) found in the file are drawn. Note that this may result
89 in empty tabs.
90
91 ;ceres:
92
93 * The night sky noise is now scaled with the sensitive area and
94 is given in units per square centimeter
95
96 * The night-sky noise now also takes the cones transmission
97 into account
98
99 * The night sky noise can now be calculated from a night-sky
100 spctrum
101
102 * A transmission curve for the cones can now be given
103
104 * Added the possibility to add a cut after the image parameter
105 calculation (''Cut'')
106
107 * updated the PDE of the GAPDs with a more reliable curve from
108 the meeting page (linear extrapolate below 350nm)
109
110 * The impact distribution in the event distrbutions is now
111 perpendicular to Alt/Az and the histogram is displayed in 1D
112
113 * The GAPD PDE has been updated
114
115 * PDEs and mirror reflectivities have been linearily extrapolated
116 to match the wavelegth range between 290nm and 900nm
117
118 * There is no default pulse shape anymoe it must be given in
119 the resource file
120
121 * Fixed a bug which caused the aerosol coefficient to be incorrectly
122 initialized. The effect might be random but seems to be small.
123
124 * Now accepts sequence files as input
125
126 * creation of pedestal and calibration files is now steered by
127 --mode (see ceres help)
128
129 * Instead of initializing the whole G-APD chip (all cells) before
130 each event (which is rather time consuming) a time evolution before
131 each event is now simulated which is enough to recovere every cell
132 to 99.999% of its response taking the background rate into account.
133 This is in total about a factor of ten faster and should not be
134 less accurate because under normal conditions the recovering cells
135 and the newly hitten cells will hardly be identical (due to
136 statistical reasons)
137
138 * improved the trigger algorithm which is now faster and allows easily
139 for multiplicity triggers
140
141 * The PDC flag in the file name is now correctly written
142
143 * A "PreCut" has been added which can be used after reading the events
144 to select them even before any calculation is done.
145
146 ;merpp:
147
148 * The new drive reports which contain also the status of the starguider
149 are now implemented, but the starting date (17/05/09) is preliminary.
150
151 ;callisto:
152
153 * Fixed a bug which prevented MAGIC Monte Carlo file from being
154 calibrated (ceres files worked)
155
156 * updated (Muon) calibration constants of period 62, 63, 72-75
157
158 ;star:
159
160 * allow to run thru even if discriminator threshold are missing
161 (they are not used for analysis so far anyway)
162
163 ;ganymed:
164
165 * added new starguider calibration for sequences since 1000534
166
167 ;database:
168
169 * added possiblity to query/plot data from certain source (with
170 regular expressions) in plotdb.php
171
172 * new feature in showplots*.php: on mouse-over additional information
173 on the sequence is displayed
174
175 * tables on database website have also 'Last' link now
176
177 * new version of builddatasets.php with more comfortable sequence
178 selection
179
180 * new features in builddatasets.php:
181 - user management
182 - 'Get Data Set File' button
183 - 'Display Selected Sequences' button
184 - 'Display Not Selected Sequences' button
185 - 'Select all' buttons
186
187 * builddatasets.php: added possibility to update data sets in the
188 database
189
190 * added limit for cloudiness for sequences in the tab 'Limits'
191
192 ;automation:
193
194 * jobmanager can be used more flexible now: via environnent variable
195 $AUTOMATIONSETUP more than one jobmanager per user can be started
196 using the same MARS version
197 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
198 and provide a file Mars/datacenter/scripts/setup.mysetup
199
200
201
202== Version 2.3 (2009/03/07) ==
203
204 ;SUGGESTION
205
206 * There is no need to re-run any data because no change took place which
207 could have an effect on the output. However, if you want a
208 meaningful SrcPos plot for your MCs in sponde you must re-process
209 star for your MCs first.
210
211 ;REMARK
212
213 * File produced with this release containing a camera geometry (which
214 are basically all files were produced as default) will not be readable
215 by older releases.
216
217 ;general
218
219 * fixed a few small bugs which could cause the display to crash in ganymed
220 and sponde
221
222 * in sequence file the date can now be omittet. In this case the
223 leading date with the underscore is missing in the expected filename
224
225 * the geometry class now also supports other geometries than just hexagons
226
227 ;automation
228
229 * added magnetic field Azimuth direction (ARRANG), currently
230 at ~ -7deg at La Palma
231
232 ;database
233
234 * plotdb.php: added default (sequences) for startup, added possibility
235 to set size of plot
236
237 * added a new table ''RunDataCheck'' which containes the rates after
238 image cleaning for every run which succeeded star. It can be
239 plotted using ''plotrundb.C''
240
241 ;merpp
242
243 * added support for Arehucas Version >= 200812140
244
245 * added support for Arehucas Version >= 200809030
246
247 ;mars
248
249 * The display now also displays the trigger pattern
250
251 * The display can now display ceres reflector (_R_) files
252
253 ;ceres
254
255 * added a uniformly distributed one-bin time jitter for the start of the
256 digitization. Otherwise the first photon would be digitized always with
257 the same alignment to the bins
258
259 * Added a plot showing the production height of the photons
260
261 * Moved the particle id from the event header to the run header
262
263 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
264
265 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
266
267 * Added many new options to control the tasks. For deatils see ''ceres.rc''
268
269 * Removed obsolete plots in pedestal and calibration mode
270
271 * Removed the non-NightSky photons from the plots where they are just
272 disturbing
273
274 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
275
276 * The daq event number now represents the readout number
277
278 * The camera ''electronics'' can now be ''switched off''
279
280 * A new tab ''Info'' now display basic things like the reflector
281 layout
282
283 * Improved reading speed for corsika files
284
285 * Improved memory handling (if a large ampount of memory was needed
286 for a single event all further events were stored in the same
287 memory and it was never freed, so the program took this memory
288 until the end)
289
290 * Converted the code from MMCS' reflector program to MSimAtmosphere
291 (instead of the tables build in for MAGIC Winter and Summer
292 atmosphere we use the values written by Corsika fitted to the
293 tabulated atmosphere given as input)
294
295 * For caluclating the displayed image parameters in ceres a basic
296 image cleaning removing isolated pixels is now done.
297
298 * The magnetic field direction (ARRANG) is now taken into account
299
300 * Added plot for the energy threshold after trigger ''Threshold''
301
302 * Added plot for the effective collection area after trigger ''TrigArea''
303
304 ;star
305
306 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
307
308 * The definition of fConcCore has slightly changed. The numbers
309 might decrease a little bit (the effect should be rather small)
310
311 ;ganymed
312
313 * added pointing model 328198
314
315 ;sponde
316
317 * The SrcPos plot for your MCs was so far meaningless because it just
318 displayes the MSrcPosCam data from the input star-files. Unfortunately,
319 this containes was never written to the star-files yet.
320
321 * A new Tab 'OnTime' is available which is an effective on-time
322 fit as in star but for all data. This is mainly for manual cross-check
323 of the effective on-time
324
325 * In some circumstances it might be necessary to re-calculate the
326 eff. on-time from the fit in the new tab, e.g. when a zenith distance
327 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
328
329 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
330 it to its own output file (for convinience)
331
332
333
334== Version 2.2 (2009/01/30) ==
335
336 ;SUGGESTION
337
338 * This release doesn't contain a major change which is expected to
339 change your results. Nevertheless there are small changes to
340 the calibration which can effect at least the first few hundred
341 events in any (mainly MUX and even more SUM) sequence a little bit.
342 So it is recommended although not necessary to reset your sequences
343 in the database before further processing.
344
345 ;NEW
346
347 * A first implementation of a Monte Carlo simulation program
348 (ceres - Camera Electronics and REflector Simulation) has been
349 implemented. It can simulate a full telescope already including
350 a complete reflector simulation and a flexible trigger and readout
351 simulation. Currently, no perfect setup is implemented and
352 especially the output of the program (data structure) should
353 be considered alpha state. Also the user interface is not yet
354 ready.
355
356 ;general
357
358 * All command line options after -- are now interpreted as
359 arguments (usually everything which doesn't start with a minus)
360 rather than options (usually everything which starts with a
361 minus). This allows to use file names starting with a -
362
363 * In all resource files you can now initialize the random number
364 generator. For details see: MJob::InitRandomNumberGenerator
365
366 * added a new program called ''readcorsika''. It's purpose is (in analogy
367 to readraw and readdaq) to read a Corsika output file (for now
368 only cherenkov output is supported) and print its contents in a
369 human readable form. It can also write the contents of this file
370 into a root-file.
371
372 * The calculation of the maximum distance to the origin in a MGeomCam
373 has been improved (edges might be further away than the sides).
374 This is just a tiny change but it might change the appearance of
375 the radial profiles a little bit.
376
377 * The default binning of the center-of-gravity plot has slightly been
378 increased
379
380 ;Database
381
382 * Added informations about the DC currents (fMinCurrents, fMedCurrents
383 and fMaxCurrents). The values are retrieved from the plots showing
384 the average DC currents of all pixels versus time.
385
386 * Websites with tables have now the opportunity to remove lines
387 ('-' button at beginning of each line) and get all lines back
388 ('+' at top of the column)
389
390 * Websites: added option to query only sequences containing sumtrigger
391 events
392
393 * Websites: added option to group by date (year, month, night) for runs
394 and sequences and enabled that combining of different group-bys,
395 e.g. status, date and source is possible
396
397 ;automatic analyis
398
399 * Rewritten producing plots in the web.
400 New plots, namely the output of plotoptical.C (extinction curve from
401 KVA), plotstat.C (status of the automatic analysis (percentage of
402 processed, analysed data etc.)) and plotusage.C (statistics of the
403 condor usage in the data center) has been are available now next to the
404 plots of plotdb.C
405 Mean values from the plots (output of the macro) are provided in a
406 txt file now.
407 The creation of the plots for callisto, star and ganymed in the web is
408 now steered via database. Consequently the plots are faster and
409 reliable up-to-date.
410 For all plots, a new layout is available facilitating the browsing
411 through the plots and providing additional information on the
412 displayed values. (tabs.php) These plots are linked from the DB
413 websites and the wiki.
414
415 ;statusdisplay
416
417 * The ''Loop'' entry in the menu bar now contains an option to pause
418 the loop and to process single events.
419
420 ;merpp
421
422 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
423 instead of RunHeaders)
424
425 * Now allows to merpp files newer than 2008/09/03.
426
427 * Added fixes for wrong (wrong or double) run- and file-numbers
428 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
429
430 ;callisto
431
432 * Extracting the pulse position for the pulse position check events
433 with sum trigger were denied. This decreased the statistics
434 extremely and therefor the resulting puse position was calculated
435 quite weak. Now sum events pass the calculation if and only if they
436 have also a level 1 trigger.
437
438 * the extraction of pedestal events and pulse position from the
439 first data events is now more automatic and makes sure that
440 a more precise number of events is extracted independent of
441 the ratio with which pedestal events or events with signals
442 are contained in the data.
443
444 * Updated Muon calibration constants for all MUX data (teh changes were
445 all smaller than 5%)
446
447 ;star
448
449 * For the calculation of the effective on time all sum-triggered events
450 were skipped. Now all Level1-triggeres events will pass. This might
451 result in a slight inaccuracy of the effective on time.
452
453 ;ganymed
454
455 * If the source position is more than 1deg away from the camera
456 center an error is raised now.
457
458 * Hopefully fixed the bug ''ganymed crashes when resized''
459
460 ;sponde
461
462 * Fixed a problem which causes the fitted spectral slope to be displayed
463 incorrectly. If you use MJSpectrum::FormFlux in your macros make
464 sure that the parameter 0 of your fit is negative.
465
466 * Added a histogram showing the read source position of your MCs
467
468
469
470== Version 2.1.1 (2008/08/04) ==
471
472 ;Database
473
474 * Added the median number of photo electrons from the calibration
475 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
476 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
477
478 * Added fTotOnTime, which is the on-time as given by the run-headers
479 (in contradiction to fAbsOnTime which comes from CC)
480
481 * Added new primaries for the new data structure (Magic II): for the
482 tables dealing with sequences (SequenceBuild Status, Sequences,
483 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
484 this is the telescope number (fTelescopeNumber) for the tables dealing
485 with runs (RunData and RunProcessStatus) this is in addition the file
486 number (fFileNumber)
487
488 * Added column fPriority to the status tables to be able to steer the order
489 in which the data is processed. As default the run, sequence and dataset
490 number are used.
491
492 ;automatic analyis
493
494 * Adapted scripts to the new data structure: They can handle now different
495 telescopes (getting the information as usual from the database).
496 The paths for Magic 2 are not yet implemented.
497
498 ;general
499
500 * should work now with root 5.20/00 (please note that root 5.20/00
501 we encounter crahses in the status display which are ot yet
502 understood)
503
504 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
505 instead of the base name of the file. This makes them easier to
506 access from the code
507
508 * Default Monte Carlo names in MSequence do not require the _E at
509 the end anymore
510
511 * where abrrevating a sequence file with a sequence number is possible
512 also "telescope:sequence" is now accepted, e.g.:
513 star 2:2000123 --out=output
514 see the programs' help for more details.
515
516 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
517 from the database. See the constructors for more details.
518
519 * MReadTree now supports friends
520
521 * MReadTree can now read also files not written by MARS and store
522 the data encapsulated in emulated MParContainers
523
524 * added a new starguider calibration valid since 15.1.08
525
526 ;showplot
527
528 * showplot can now read more than one file at once. This is especially
529 inetersting if reading files containing pure canvases
530
531 ;merpp
532
533 * we merpp the dc currents now also from the camera reports (they have
534 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
535
536 * In the automatic analysis we omit merpping of the currents from the
537 caco files and use the lower rate camera reports from the cc files
538 instead
539
540 * merpp has been redisigned to allow merpping of the cc-reports
541 of a whole sequence. This allows to design a very simple analysis:
542 mkdir output
543 ./callisto 100776 --out=output
544 ./merpp 100776 output
545 ./star 100776 --ind=output --out=output
546 Instead of the sequence number also sequence files are accepted.
547
548 * Implemented a fix for run-numbers between 1001348 and 1001396
549 which were incorrectly assigned by the cc.
550
551
552 ;callisto
553
554 * added a filter again which was was removed in the last release.
555 it removed the most brightest events. This should not change
556 any analysis result because these events are so bright that
557 they cannot be analysed anyway, but the bad-pixel plots doesn't
558 show outliers.
559
560 * updated muon calibration constants for the periods 51-57,
561 58-63 and 67-
562
563 ;star
564
565 * The camera currents are now displayed with the rate of the camera
566 reports instead of the caco reports
567
568 ;ganymed
569
570 * if mc camera files are new enough (>=8) the source position in the
571 camera is now calculated from the stored telscope and shower
572 orientation (Note, that this might not be suitable in all cases
573 depending on the aim of the study. These case still needs
574 implementation)
575
576
577
578== Version 2.1 (2008/06/18) ==
579
580 ;Database
581
582 * introduced average temperature and wind speed from star-files
583
584 * introduced average values from Pyrometer (mainly Cloudiness)
585
586 * introduced the ratio of accepted calibration events in the
587 calibration run
588
589 * introduced the average rates of the different trigger pattern,
590 e.g. the rate of pedestal and calibration events, from the signal-file
591
592 ;general
593
594 * fixed GroupBy options in plot*.C macros
595
596 * only display KVA points (not the Tuorla points) in plotoptical.C
597
598 * all programs now allow to add resources to the ones from the resource
599 file or overwrite them from the command line. This can be done like this
600 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
601 if something seems to be wrong you can debug what the program is doing
602 using the option --debug-env=3
603
604 * increased the diversity of debug levels. That also means that with -v3
605 you get now less output, i.e. only the output which is important for
606 an analysis. To get more output which helps for debugging try 4, 5 and 6.
607
608 * fixed a problem in the task synchronizing the reading of the reports
609 and the data stream. The effect was that in some circumstances the last
610 events of some trees could have been skipped. Since this is only a
611 very tiny part of the data no severe effect to your analysis results
612 is expected (an exception might be very short, i.e. singel runs,
613 datasets).
614
615 * Dataset file now allow to include the sequence file directly within
616 the dataset file and also allow to exclude single runs from the dataset.
617 (for more details see Class reference of MDataSet)
618
619 * Sequence files now allow for excluding runs from the analysis
620 (for more details see Class reference of MSequence)
621
622 * added code to process the sum-trigger flag
623
624 * the histogram classes MH3 and MHn now support profile histograms
625
626 * the histogram classes MH3 and MHn now support labels at the axis
627
628 * the Random Forest Train-classes (MJTRain*) now store the used datasets
629 in the output file
630
631 * the MFMagicCuts have a new option to allow a linear area cut (for
632 special studies)
633
634 * The liniking of the shared object is now done into a file defined
635 by 'mktemp'. This should be a local file system which accelerates
636 liniking a lot.
637
638 * The code has been prepared for compilation with root 5.18/00d
639
640 * The MHEnergyEst histogram now shows the distribution of
641 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
642 and (Eest-Emc)/Emc vs Emc.
643
644 * fixed mars (event display) for merpped raw-data and MC data
645
646 * adapted the synatx of sequence files to allow for the new run/file
647 scheme. For more details see class description of MSequence
648
649 ;showplot
650
651 * Added support for tiff files
652
653 * Added support for csv files (tables containing tab number,
654 name and title)
655
656 * Tabs now can have a title which is displayed in the postscript file
657
658 * When multiple file are written at once (e.g. pngs from a display)
659 it is now possible to use the tab name and or tab number in the
660 file name. For details see showplos's help.
661
662 ;merpp
663
664 * Implemented cc file version 2008-02-20/0
665
666 * Implemented cc file version 2008-05-19/0
667
668 * With new options merpping can be restricted (in addition to the
669 run-number) also by telescope and file number.
670 For details see "merpp --help"
671
672 * Implemented raw data format 11 (the most important change, except
673 from plenty of changes in the format definition, is the addition
674 of the file-number in the header) If nobody makes a mistake this
675 format should have the advantage that it is by definition forward
676 compatible, so old programs will be able to read newer formats.
677
678 * Added Pyrometer information to default output (stored in a new Tree
679 Pyrometer, needs a complete new merpp, i.e. new calibration)
680
681 * Merpping (also update) can now be restricted to one single report.
682 For example:
683 If you want to update an old file with Pyrometer information call
684 merpp --only=Pyrometer --update
685
686 ;callisto
687
688 * in the pedestal processing now at least 50 processed events are
689 required for succeeding.
690
691 * the signal and calib files now contain also the sequence information
692
693 * the two MPedestalCam in the calib file now have proper names
694 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
695
696 * Both pedestal cams now contain the number of events processed
697
698 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
699 i.e. for the extraction of the calibration pulses basically the average
700 over all events of the first slice instead of all slices was used.
701 Since pedestal and calibration constants are continously recalculated
702 this only effected the very first events of every sequence.
703
704 * For the extraction of the position of the maximum sample now the
705 extraction range is set automatically to the extraction window,
706 before the whole accessible range was used.
707
708 * If the number of samples in the events and the number of samples
709 in the run-header disagrees now an error is raised (this can
710 happen in not well simulated Monte Carlo files)
711
712 * In the case of MUX-data pedestal events with the lvl1 trigger flag
713 could survive into the pedestal calculation -- fixed.
714
715 * Tab "TrigPat" added showing the distribution of the trigger pattern
716 as found in the run-files (normalized with the run length)
717
718 * The selection of events from the trigger pattern has been improved.
719 If the trigger pattern is corrupted events won't pass anymore.
720
721 * Added a new command line option --dev-null to suppress output of
722 Y-files (this is useful for test cases)
723
724 * added a new tab "CalPos" showing the arrival time of extracted
725 interleaved calibration events
726
727 * Using the new --test switch you can now calibrate the calibration
728 file
729
730 ;star
731
732 * the star file now contains also the sequence information
733
734 * Added a new command line option --dev-null to suppress output of
735 I-files (this is useful for test cases)
736
737 * Tab "Rate" added showing the distribution of the trigger pattern
738 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
739 the Y-files (normalized with the run length)
740
741 * The effective on-time calculation doesn't use events with only
742 sum-trigger anymore
743
744 * The data in the MHWeather tab has been reorganized. The never
745 working solar radiation has been removed and the data from
746 the pyrometer (cloudiness, air and sky temperature) is
747 displayed in addition.
748
749 ;ganymed/sponde
750
751 * Now data points are even shown correctly if they have error bars larger
752 than one sigma. Points with null or negative significances are omitted.
753
754 * DrawNicePlot now allows to set a projection range
755
756 * Updates pointing models. One is applied after the implementation
757 of the new LUTS in August, the other one is applied after the
758 next major change of the pointing model in October. Note that
759 these models are preliminary and give wrong results below Zd=65deg
760
761 ;sponde
762
763 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
764
765 * a new option "--force-runtime" is available. In case of very short
766 datasets (for light-curves) which are in the order of a few
767 minutes the calculated effective on-time is not very acurate because
768 it is quantizised in the order of a minute. Therefore you can switch
769 to using the real run-time instead (remakrt: this ignores any
770 dead-time!)
771
772 * a more analytical way is used to "fill" Monte Carlos into regions
773 of impact parameters which have not been simulated because the
774 trigger efficiency is assumed to be 0.
775
776 * estimated sensitivity curves for hi and lo zenith angles are shown
777 scaled to the correct observation time and collection area
778
779 * the Monte Carlo events after cuts are now written to the output file
780 if an output file given
781
782
783
784 *** Version 2.0 (2007/09/03)
785
786 - database: the position used for the pulse pos check was missing
787 in the callisto output and could thus not be filled into the DB.
788 Also the old values seemed not exactly the PulsePos used for
789 teh check.
790
791 - general: Resource file now allow an Include-Resource, i.e. you can
792 read a resource file with default settings, include it in your
793 resource file and overwrite the settings in your file. More than
794 one include file is allowed. Inclusions can be iterative.
795 Include: mydefaults.rc yourdefaults.rc
796 The resources in the first file have higher priority than the
797 second file.
798
799 - general: Now the output files (calib*.root, etc) also contain the
800 resource file (to check it open it in the TBrowser and choose Print()
801 from the context menu)
802
803 - general: Dataset files now allow to overwrite the default path
804 to search for sequence and data files. Note, that the program
805 option and individual resources will overwrite it. For example:
806 SequencePath: /magic/montecarlo/sequences
807 DataPath: /magic/montecarlo/star
808
809 - general: Fixed a problem with variables in MDataPhrase. It seems
810 that only optimdisp (didn't work) was effected.
811
812 - general: Some improvements to the optim and train processing. For
813 example the ststud window now got a proper title.
814
815 - general: The "Status Display: " was removed from the window title
816 within an Eventloop.
817
818 - general: added a new flexible histogram-class (MHn) which can be used
819 for example in testing after optimizations or training to produce
820 user defined histograms.
821
822 - general: The Random Forest now allows attaching an evaluation
823 function which is applied to its output. This allows to train
824 on whatever you like (eg. train on log10(energy), but return
825 energy)
826
827 - general: The Random Forest training of energy (trainenergy.c) and
828 disp (traindisp.C) has been improved by more graphical output to
829 judge the result.
830
831 - general: The training of energy (trainenergy.C) has been improved
832 a lot by training on a different quantity than energy. It gives
833 a result which is highly independant of the source spectrum
834 and shows lower bias than all other options.
835
836 - general: Dataset files are allowed to contain collections of
837 datasets. For more details see the class reference of MDataSet.
838
839 - general: The default WobbleMode in a datset file now (if not
840 overwritten) is "auto", i.e. wobble mode is set if the dataset
841 doesn't contain off-sequences.
842
843 - merpp: Merpp can read file format version 9 now. Please realize
844 that for file format version 9 the extraction range is different
845 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
846 the first and last 15 slices have been removed from all MUX data.
847
848 - mars: Similar to writing movies you can now select events which
849 should be displayed in your display. Therefore add the following
850 lines to your mars.rc:
851 MFEvtNumber.FileName: ganymed00223552.root
852 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
853 The input file can be a ganymed-file after (ganymed*.root) or
854 before (ganymed*-summary.root) file. For example to select all events
855 from your on sample after cuts (excluding the ThetaSq cut) use
856 MFEvtNumber.Selector: DataType.fVal>0.5
857 To show all events from your on-sample after quality cuts
858 use the summary file instead.
859
860 - mars: new ways to call mars are implemented. Instead
861 of calling
862 mars filename.root
863 you can now also use
864 mars sequence.txt
865 or
866 mars sequence.txt inputpath
867 or replace sequence.txt by the sequence number if the default
868 sequence file should be used.
869
870 - mars: The default size has been increased
871
872 - mars: There are two new heckboxes which allow to switch off
873 the calculated image parameters
874
875 - callisto: was broken for MCs... fixed.
876
877 - callisto: improved calculation of spline coefficients a lot. This
878 leads to a further improvement of the event rate calibrating MUX
879 data of about 15% (175evt/s instead of 150evt/s)
880
881 - callisto: finally the raw data we read is now real 16bit (with
882 10bit precision) for MUX data and not a stripped 8bit number
883 anymore. Due to scaling of the numbers (without precision loss
884 into an [0-256[ range, the final numbers for pedestal, pedestalrms
885 and extacted signal don't change. However, at all places where
886 raw data is directly accessed (eg. saturation and variation
887 limits in the signal- and pedestal-extraction) the numbers
888 refer still to the data's 16bit range.
889
890 - callisto: The maximum arrival time difference used in the bad
891 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
892 for both, old FADC and MUX-FADC, data.
893
894 - callisto: Be aware that callisto is now calibrating the arrival time
895 in nanoseconds rather than time slices. Also all following tasks
896 have been changed to assume ns units now. If you star data
897 calibrated with an older version it might be necessary to adapt
898 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
899 to obtain optimal results. The plot in the PulsePos tab
900 will now be in ns, too. This might also mean that the Muon
901 analysis in star might not work as perfect as expected as long
902 as old files read in.
903
904 - callisto: The calibration constants of earlier updates got lost
905 somehow. All constants have been updated.
906
907 - star: The PSF is now determined from the profile of the ArcWidth
908 instead of arcwidth/radius. The old way gave to much weight
909 to the bins with low statistics. The reference lines have been
910 updated.
911
912 - star: For speed reasons events suitable for the muon analysis
913 are now also preselected by fConcCOG<0.1 which seems to be a very
914 good preselector for muons.
915
916 - star: is now calculating a new timing parameter the Slope along
917 the major and minor axis of the shower. Therefore a numerical
918 solution of a line-fit is used. To use MHillasExt.fSlopeLong
919 and MHillasExt.fSlopeTrans don't forget to multiply it with
920 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
921
922 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
923 have been removed from MNewImagePar. They have never been good for
924 anything.
925
926 - star: Implemented a new recursive algorithm which is supposed to be
927 faster. Also implemented new cleaning oiptions, which are:
928 + CleanLevel0:
929 The cleaning level above single core pixels can be kept
930 + KeepIsolatedPixels:
931 Define whether single core pixels should be kept
932 + TimeLevel1:
933 The coincidence window in nanoseconds to single used neighbors
934 + TimeLevel2:
935 The coincidence window in nanoseconds to two used neighbors
936 + PostCleanType:
937 MOde in which a time dependent post cleaning should be applied
938 0: No post cleaning
939 1: Require for each used pixels at least one used neighbor
940 within a time-window of CleanLevel1
941 2: Require for each used pixels at least two used neighbor
942 within a time-window of CleanLevel2
943 3: Require first two and second one used neighbor
944 within a time-window of CleanLevel1 and fCleanLevel2
945 respectively
946 + RecoverIsolatedPixels:
947 - recoveres isolated core pixels if they have a used neighbor
948
949 - mars/star: The new default cleaning is:
950 + CleanLevel1: 6.0
951 + CleanLevel2: 3.0
952 + CleanTime1: 1.75
953 + CleanTime2: 1.75
954 + PostCleanType: 3
955
956 - star/ganymed: The old spark-cuts have been replaced by new ones.
957 These new spark cuts have been cross checked with the sequences
958 84720 (before splitter), 101041 (after splitter) and 223539 (new
959 FADCs). In all cases they seperate pretty well, but of course not
960 perfect. Monte Carlos have suggested to tighten the cuts a little
961 bit further at low sizes. This has been done.
962
963 - ganymed: IMPORTANT - The spark cuts have been changed to match
964 all available data more or less well. This might mean that for
965 YOUR data there are still sparks visible.
966 Whenever you do an analysis you have to make sure that NO sparks
967 survive your cuts!
968
969 - ganymed: The old hadronness and size cuts have gotten new indices
970 (10, 11). The old indices 8 and 9 now mean an additional condition
971 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
972 If you want to switch off this cut just move the line far away enough,
973 e.g. by setting c[9] to -500. Please update your ganymed.rc files
974 accordingly!
975 The unit of c[9] is deg. It is the dist at which your cut will
976 cross the slope==0. The unit of the slope is ns/deg. So if
977 you readin files calibrated with an older Mars-version you
978 have to adapt the default value for c[9] to the FADCs:
979 - Multiply by two for the MUX FADCs (run number > 200.000)
980 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
981 - Multiply by 42 for the meaning of life (run number = 200.000)
982
983 - ganymed: The old Cut0 is now called CutQ and is calculated before
984 the source position is caluclated. If you need a quality cut
985 including source dependant data (be very carefull with this!)
986 you have to use Cut0 instead.
987
988 - ganymed: now properly supports three off regions in wobble mode.
989 It will be the default from now on in ganymed_wobble.rc. To change
990 the number of off-regions use
991 NumOffSourcePositions: 1
992 in your ganymed.rc. Also by default no off-theta cut will be done
993 anymore so that you will get a background level higher than the
994 signal level in your ThetaSq plot for ThetaSq>0.2.
995 Due to this be carefull changing the scaling mode away from
996 "None". You will underestimate your signal if your scale interval
997 is not properly set.
998 (Rem: ThetaSqN is no longer needed)
999
1000 - ganymed: is now storing the events of all (on- and off-)
1001 source positions even in the case of more than one off-source
1002 position. This should allow sponde to work properly and the
1003 energy estimation is done correctly in all cases (without any
1004 "nearest position" trick)
1005
1006 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
1007 with a real pointing model for the starguider is done, calibrated
1008 with more than thousand tpoints taken from this date on.
1009
1010 - ganymed: was broken for Wobble-MCs... fixed.
1011
1012 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
1013 has changed. Note that your old ganymed.rc will be incompatible
1014 with the new algorithms! Please check the ganymed.rc files and
1015 the class description of MFMagicCuts for more information.
1016 It is recommended at the moment to use identical Disp-Parametrizations
1017 for on/off- and wobble-mode. If cuts are optimized only
1018 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
1019 should be optimized. All other values should be kept as they are.
1020 If you want to do an anylsis without timing a parameters, you can
1021 switch off the timing cuts by seeting parameter 7 to a very small
1022 value (eg. -99). To remove the slope parameter from the disp
1023 paremtrization set parameter 8 to 0.
1024
1025 - ganymed: The distribution of observation time versus zenith
1026 angle is now shown for off- AND on-data.
1027
1028 - ganymed: The contents of the source position plot are no longer
1029 averaged, thus a lot of (fake) events between the two wobble
1030 positions have disappeared.
1031
1032 - ganymed: There is a new tab "CutT" it contains the VsSize plots
1033 with the CutT, whihc is defined in ganymed.rc, applied. It
1034 is resonable to use your theta-cut for it, to see if there is
1035 something strange (sparks!) in your signal-region.
1036
1037 - ganymed: To choose a dataset from a collection in a dataset file
1038 use the new command line option "--dataset=12345"
1039
1040 - optim, sponde: should now properly support three off-regions.
1041 Just produce your ganymed summary files with three off-regions.
1042 optim and sponde will automatically get all off events from
1043 all off-regions from this file. Please do not forget to
1044 set the scaling in optimwobble.C properly:
1045 fit.SetScaleUser(1./3);
1046 it is not yet read in automatically (will follow soon).
1047 In the case of fixed Scale you can also use
1048 cuts.SetThetaCut(MFMagicCuts::kOn);
1049 no off-cut needed.
1050 Be carefull in case of three off-regions when switching on
1051 scale mode. Make sure that the scale interval is set correctly.
1052
1053 - sponde: sponde.rc and sponde_onoff.rc are now idetical
1054
1055 - sponde: the resouce files have been rewritten with a lot of
1056 comments and a well working parametrization for an energy estimator
1057
1058 - sponde: In the estimated energy versus monte carlo energy plot the
1059 contents where exchanged.... fixed.
1060
1061 - sponde: the so called "accurate"-mode has been removed. It didn't
1062 give any improvement in accuracy, only decreased execution speed.
1063
1064 - sponde: the so called "simple"-mode has been removed. It didn't
1065 give any improvement in simple.
1066
1067 - sponde: the so called "refill"-mode has been removed. It was anyhow
1068 not implemented.
1069
1070 - sponde: now checks whether the theta distribution of your on-data
1071 and the theta-distribution of your Monte Carlo sample (after
1072 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
1073 sample is incomplete) execution is stopped. Execution can be forced
1074 using the new option --force-theta. Use this option with care!
1075
1076 - sponde: Proper collection areas can now be constructed also from
1077 Monte Carlo samples generated with different maximum impact
1078 parameters. Note that in previous version you neither got
1079 a warning or failure, nor was there any obvious sign that the
1080 collection area was overestimated due to usage of files with
1081 different maximum impact parameters.
1082
1083 - sponde: If MC files with different lower energy limits are used
1084 the primary MC spectrum is artificially completed down to the
1085 lowest energy used at all. WARNING: that this gives correct
1086 collection areas ONLY if none of the events in this region would
1087 survive your cuts at all.
1088
1089 - sponde: the output file now contains more information about
1090 the spectrum (eg. the full 2D collection area histogram).
1091 Note, that this information can only be written to the file
1092 if it is stored automatically via command line argument.
1093 If you only store the status display from within the display
1094 the information is lost.
1095
1096 - sponde: added a new tab "Disp". It shows the residual of the disp
1097 (Disp-Dist) versus several parameters and it is meant to judge the
1098 quality of the disp estimator. In the ideal case the residual is zero
1099 and doesn't depend on any variable. The tab is displayed after
1100 CutQ and Cut0.
1101
1102 - sponde: added a new tab "Energy". It shows the residual of the
1103 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1104 several parameters and it is meant to judge the quality of the
1105 energy estimator. In the ideal case the residual is zero
1106 and doesn't depend on any variable. In reality even a good estimator
1107 can show residuals versus Monte Carlo energy. The tab is displayed
1108 after all cuts.
1109
1110 - sponde: added a new tab "EventDist" showing the unweighted real
1111 absolute number of events of your sample after cuts. This tells
1112 you how many events with this energy you had in your MC files.
1113 The same information you get from the error bars of the weighted
1114 histograms, but this is less intuitive.
1115
1116 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1117 for comparison. It is not meant to show these curves in
1118 publications, they are only for production.
1119
1120 - sponde: The OriginalMC tree with the events produced by corsika
1121 is now processed only once
1122
1123 - sponde: Finally fixed most annoying bug, which has effected the
1124 last bin of the collection area. It was the problem that binnings
1125 of root histograms are from 1 to n (included) but there was a C-like
1126 loop in sponde from 0 to n (excluded). Now the loop also includes
1127 correctly under- and overflow-bins. The worse thing with this is,
1128 that for the events in the highest bin not only the bin-content
1129 was wrong, but also the weights applied to these events, which could
1130 in pricipal effect also other parts of the distribution (eg. due
1131 to energy estimation). Fortunately it effected only a few events
1132 in most cases.
1133
1134
1135
1136 *** Version 1.2 (2007/05/14)
1137
1138 - database: The database now has two new values Unsuitable50 and
1139 Unsuitable01. They express the number of pixels which are
1140 unsuitable for more than 50%, respectively more than 1%, of
1141 all calibrated event. It is a more accurate number than the
1142 previously used numbers, because they only take the first
1143 calibration (ignoring the interleaved calibrations) into account.
1144
1145 - database: The database now has two other new values UnsuitableMax and
1146 DeadMax. They express the maximum number of pixels which were
1147 unsuitable, respectively dead, during the sequence. Because
1148 of high pedestal rms (cars passing) a few events with very high
1149 numbers of unsuitable pixels can happen. Not to suffer from this
1150 effect we don't take the highest 0.1% of the numbers into account.
1151
1152 - general: fixed a bug which caused callisto and star to stop working
1153 properly because the callisto output was currupted
1154
1155 - general: a script called scripts/makemovie has been added which
1156 simplified the process of producing several movies from a single
1157 sequence with different setup.
1158
1159 - callisto: Some more code cleanup. Started to remove old obsolete
1160 code from cvs.
1161
1162 - callisto: The extraction of the pedestal with the extractor was
1163 not random. It seems that extracting at one position is still biased
1164 (for example in the first or last slices we could still suffer from
1165 switching noise) Now it is completely random.
1166
1167 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1168 pedestal files) individual pixels could be skipped due to high
1169 variations. This was already the case for the pedestal extraction
1170 from the lo-gains since the beginning and properly handled
1171 there, but was introduced in the extraction from the pedestal files
1172 a while ago. To calculate the average value it was still divided
1173 by the number of events procesed not by the number of summands
1174 really summed. This let to a pedestal which was a tiny amount too
1175 small (for a few piels in the order of 0.1%). This led to an slightly
1176 positive offset of the randomly extracted pedestal for a few pixels.
1177 I doubt that this has a big effect on the result, because the effect
1178 on the individual numbers is quite small. Due to this it is suggested
1179 that you rerun your calibration to make sure you are without any
1180 avoidable bias.
1181
1182 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1183 the median rms of the absolute arrival time and expressed in significance
1184 levels. This replaces the old meaning of an abolute upper limit. An
1185 absolute upper limit doesn't make much sense, because in our data
1186 all arrival times are shifted at the same time (in fact it might be
1187 a shift of the artificial trigger w.r.t. to the light flash).
1188
1189 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1190 of the number of unsuitable pixels over the whole sequence. This
1191 is usefull mainly to judge if an intermediate calibration had
1192 problems.
1193
1194 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1195 of the number of dead pixels over the whole sequence. Dead pixels
1196 in this context are unmapped pixels, i.e. pixels which could not
1197 be interpolated, and thus are ignored in the further analysis.
1198
1199 - callisto: It is now possible to use the position of the maximum
1200 of the spline as arrival time instead of the leading edge even
1201 when using the integral for the signal. Therefor set the extraction
1202 type to kIntegralRel ("IntegralRelative") and the relative height
1203 ("HeightTm") to -1:
1204 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1205 MJPedestalC1.ExtractSignal.HeightTm: -1
1206
1207
1208
1209
1210 *** Version 1.1 (2007/04/27)
1211
1212 - general: The new class MGeomCamDwarf contains the camera geometry
1213 for our prefered Dwarf camera and can be used to create general
1214 geometries of roundish or hexagonal cameras.
1215
1216 - mars: The default cleaning is now abolute 8.5/4.0.
1217
1218 - mars: The resource file mars.rc now contains examples for MUX data
1219
1220 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1221 data containing only 10-bit information is still cooked down to
1222 8-bit, by cutting away the lowest 8-bit.
1223
1224 - merpp: When reading raw data the data is now stored in a single
1225 array. The lo-gain array is obsolete. The interface stays the same.
1226
1227 - callisto: To process the new MUX data use the resource file
1228 callisto_mux.rc
1229
1230 - callisto: The -root and -raw options to read merpped raw data have
1231 been removed
1232
1233 - callisto: If the -mc option is given the sequence-name can now be
1234 replaced by the MC sequence number
1235
1236 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1237 -mc option can now be omitted
1238
1239 - callisto: Started further simplification by removing obsolete
1240 dependancies on MCalibIntensity*Cams.
1241
1242 - callisto: removed unsused intensity calibration from MJCalibration
1243 for further simplification
1244
1245 - callisto: for simplification removed references to
1246 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1247 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1248 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1249 (this should at minimum change nothing at all, and at maximum
1250 improve thing if these containers where somewhere not handled
1251 properly)
1252
1253 - callisto: Added the option to write an event movie. Please use
1254 this option with care (huge files) but exessively to understand
1255 our events. For further documentation please refer to the
1256 IACT wiki
1257 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1258
1259 - callisto: Improved binning for the pulse position check histogram
1260
1261 - callisto: The code calculating the pulse position checknow takes
1262 the pedestal into account
1263
1264 - callisto: The arrival time is now stored with full precision this
1265 helps to get rid of artefacts in histograms. For the signal this
1266 is not necessray because it is displayed in log-scale anyhow
1267
1268 - callisto: Fixed a problem with internal exclusions. Pixels which
1269 have once been marked as unsuitable didn't get the necessary
1270 histograms filled anymore to be rechecked with each interleaved
1271 calibration.
1272
1273 - callisto: The relative arrival time resolution (the rms of the
1274 relative arrival time offset) is now checked against its
1275 median and the median deviation, instead of the average
1276 plus an absolute offset.
1277
1278 - callisto: The relative arrival time offset is now calculated
1279 w.r.t. its median not w.r.t. to an artificial reference pixel.
1280
1281 - callisto: The relative time calibration now marks pixels with
1282 outlaying offset as unsuitable
1283
1284 - callisto: The interleaved relative time calibration has been switched
1285 on. The advantage is that pixels which are marked as outliers
1286 now can recover. An improvement over time is not expected, because
1287 the relative time calibration seems stable.
1288
1289 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1290 option can now be omitted.
1291
1292 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1293 or the option "-mc" is specified as default the monte carlo datacenter
1294 paths (/magic/montecarlo/...) are used if not overwritten in the
1295 dataset file.
1296
1297 - ganymed: The output files now contain run- and event-number for all
1298 events, accessible as RunNumber.fVal and EvtNumber.fVal
1299
1300 - ganymed: Added a plot showing the source position in the camera also
1301 for wobble mode
1302
1303 - ganymed: In addition to the existing task which can be setup to
1304 be executed after Cut1 a final task called "EstimateEnergy"
1305 has been added, executed before writing the final output
1306 (ganymed00000000.root). The task setup in all three cases
1307 can be choosen individually. (For all three(!) cases you
1308 can for example choose MRanForestCalc. For examples see all
1309 sponde*.rc and all ganymed*rc)
1310
1311 - ganymed: If a container "MEstimatedEnergy" is found in the
1312 parameter list (eg. because it was setup by MEstimateEnergy)
1313 it will be written to the output file.
1314
1315
1316
1317 *** Version 1.0 (2007/02/16)
1318
1319 - database: Website to plot values from the database has been added.
1320
1321 - database: The rate of spark events as found by star is now kept
1322 and the rate after cleaning is now with spark events subtracted
1323
1324 - general: The changes to the interpretation of phrases lead to
1325 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1326
1327 - general: Added example files how you can create your own calendar
1328 (eg. as christmas present) with Mars. Just run
1329 root macros/tutorials/calendar.C
1330
1331 - general: Added a possibility to display grouped data in the plotdb.C
1332 macro (and similar macros). This allows to plot hourly, nightly,
1333 weekly, monthly and yearly averages.
1334 For more details see the plotall function of the macro
1335
1336 - general: fixed the error display of the camera display. It showed
1337 wrong results.
1338
1339 - general: fixed a memory leak when reading many MStatusDisplays
1340
1341 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1342 between a spherical and a parabolic mirror
1343
1344 - callisto: We have a new pulse position check which takes the properties
1345 of the extractor automatically into account. So no need to set
1346 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1347 left is done. If possible the lo-gain extraction start and hi-gain
1348 extraction end is changed accordingly. If no proper extraction range
1349 can be set (hi-gain too much to the left) an error is raised.
1350
1351 - callisto: New swapped pixels have been found and corrected
1352
1353 - callisto: Redone the signal extraction this includes:
1354 + Unified the algorithms to extract the pedestal for all pedestal
1355 extractions done
1356 + Unification of hi- and lo-gain into one array
1357 + Unification of hi- and lo-gain extraction for Spline and
1358 Digital Filter (means now exactly the same algorithm is used,
1359 not a copy-and-pasted one)
1360 + Store pedestal subtracted data in a common place
1361 + Improved extraction algorithms. If the algorithms search a
1362 maximum but don't find one they don't return the maximum anymore
1363 + Improved the extraction such that a information for signal
1364 and time which is consistent is returned
1365 + replaced the numerical spline with a (not slower) analytical
1366 solution
1367 + Lowered the saturation limit from 250 to 245 to make sure that
1368 we are far away in all pixels from problems with the clock-noise
1369 + The start of the lo-gain extraction is calculated from the hi-gain
1370 arrival time. In case of saturation an estimation is used.
1371 + the hi-gain window was extended to slice 16. This allows extraction
1372 of very late pulses in single pixels or of huge hadron showers.
1373 + Now uses the lo-gain extraction range for pedestal extraction,
1374 not the hi-gain range in the lo-gain
1375
1376 - callisto: New hi-/lo-gain calibration constants have been produced
1377 for all periods from the statistic of the whole period. They are
1378 now used automatically depending on the periods. The old constants
1379 where deviation in avarega about 2%-3%. The constants are very
1380 stable from period to period (<<1%) except for exchanged channels.
1381 In a few cases the constants used so far were off by 1%-2% (maybe
1382 temperature effects?)
1383
1384 - callisto: To gain obsolete space we do not write the
1385 MPedestalFundamental anymore. Also calibration and bad pixel
1386 treatment is not done for it anymore because it has never been used.
1387
1388 - callisto: Fixed a bug in the seuqence handling which caused the
1389 light condition to be ignored
1390
1391 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1392 basically the same as "Cleaned" but the distribution devided into
1393 the events fullfilling a spark cut or being rejected by it.
1394 This cut can be changed from star.rc (see example inside) by
1395 the "SparkCut" directive
1396
1397 - star: Star displays now the average individual pixel-rate (IPR) versus
1398 time and the average discriminator threshold (DT) of all pixels.
1399
1400 - optim: fixed a problem with the optim-macros which was due to a bug
1401 in the new phrase parsing
1402
1403 - ganymed: To get a nice FalseSource plot (instead of the all-information
1404 debug plot displayed as a standard plot) use the context menu
1405 somewhere between the two upper plots, click on "DrawNicePlot"
1406 and enjoy the result. (It is the same context menu which contains
1407 the other options)
1408 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1409
1410 - ganymed/optim/train: The cut program, trainings- and optimization
1411 macros could run with less files found than expected from the
1412 sequence-files. No the execution is stopped in this case.
1413
1414 - ganymed: now stores the dataset in the output file with all information
1415 contained (as sequence number, sequence path, data path) so that the
1416 used dataset file can be recreated complete from the output
1417
1418 - sponde: now also allows the uasge of random forest
1419
1420 - sponde: added a plot showing the cut efficiency
1421
1422 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1423 errors (eg. effecting the collection area) because the errors of the
1424 two histograms were swapped in the calculation, which makes a difference
1425 in the case the histograms contains weighted events. Aditionally the
1426 totalarea was incorrectly taken into account, which results in too small
1427 errors, which makes a difference at low statistics were the errors
1428 or the collection area dominate.
1429
1430
1431
1432 *** Version 0.10.3 (2006/10/23)
1433
1434 - database: Implemented ObservationMode flag in websites.
1435
1436 - database: For sequences there is now also the stoptime available on the
1437 websites.
1438
1439 - database: Removed ManuallyChanged flag from sequence-info websites,
1440 as it is not needed anymore with the new sequence building algorithm.
1441
1442 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1443 Class for calculation of confidence intervals (upper limits).
1444 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1445 Please read the class instruction of TRolke for more information.
1446
1447 - general: The programs now return 0xfe if the requested resource file
1448 doesn't exist.
1449
1450 - general: Errors comming from root itself are now not output to
1451 stderr anymore but to our default (colored) log-stream.
1452
1453 - general: Changed the interface to TFormula such that now everything
1454 is parsed by TFormula, which should allow to use phrases even
1455 without paranthesis correctly parsed.
1456
1457 - callisto: replaced the AdHoc number of effective integration slices
1458 in the digital filter by an average of the correct number, averaged
1459 over all possible set of weights. This also gives correct numbers
1460 for the lo-gains which were totally wrong before.
1461
1462 - callisto: drastically reduced memory consumption by not storing
1463 all intermediate calibration results in memory anymore (we might
1464 write them into a file in the future)
1465
1466 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1467 debug plot displayed as a standard plot) use the context menu
1468 somewhere between the two upper plots, click on "DrawNicePlot"
1469 and enjoy the result. (It is the same context menu which contains
1470 the "DrawAll" option)
1471 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1472
1473
1474
1475 *** Version 0.10.2 (2006/10/15)
1476
1477 - general: changed the building of the sequence files such, that
1478 the source-/project name in case of wobble-sources is not the
1479 source/project of the first data run anymore but the new generalized
1480 wobble source/project
1481
1482 - general: Added some functions to MAstro to calculate sun and
1483 moon properties
1484
1485 - general: Added two new macros (starvisday.C and starvisyear.C)
1486 which allow to plot the visibility of several stars in one day
1487 or of one star along one year
1488
1489
1490
1491 *** Version 0.10.1 (2006/10/11)
1492
1493 - general: HTML logging output was distorted... fixed.
1494
1495 - general: Changed the writing of the sequencefiles such that only
1496 as many pedestal files as giving at least 1000 pedestal events which
1497 are nearby the first calibration run are used as pedestal runs
1498
1499 - sponde: In the calculation of the collection area(s) and the
1500 distribution for MOnte Carlo and estimated energy the error
1501 calculation was wrong because root didn't take the errors
1502 properly into account... fixed.
1503
1504
1505
1506 *** Version 0.10 (2006/10/10)
1507
1508 - general: all executables now check consistency of the root version
1509 installed with the root version used for compilation. The return
1510 code in this case is 255.
1511
1512 - general: The algorithm to build seqeunces has been redesigned
1513 completly. It is now more flexible in terms of a resource file
1514 resources/sequences.rc which can be used to partly overwrite
1515 the default algorithm and defined the important part of the
1516 algorithm. It also takes correctly into account several ways
1517 of taking wobble-data. Currently the new algorithm doesn't take
1518 the number of pedestal events anymore into account (so a sequence
1519 could have much less than 1000 pedestal events and data runs are
1520 no-more used instead)
1521
1522 - general: a lot of small changes to make the code compatible with
1523 root 5.12/00 and gcc 4.1
1524
1525 - general: Fixed some warnings thrown if more warnings are switched
1526 on in the compiler
1527
1528 - general: Added a function to MMath which returns the Median of
1529 the distribution abs(y[i]-median) but at 68:32 division instead
1530 of 50:50, which is somehow the median counterpart of the rms.
1531
1532 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1533 even if they are compressed with gzip (recommended compression
1534 is with "-1")
1535
1536 - showplot:
1537 + batch mode creation of image files now works with root 5.12/00
1538 + added support for writing bmp (though it never produces
1539 bmp which can be read by programs like xv or gimp)
1540 + added support for xml
1541 + added new option to start the display with a different size, by
1542 --display-width=nnn or --display-height=nnn
1543 + added options to define the canvas size when the display is started
1544 --canvas-width=nnn or --canvas-height=nnn
1545 the option can also be used for batch-mode conversion
1546 + added an option which automatically fits the display size to the
1547 desktop-size: --auto-size
1548
1549 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1550
1551 - merpp: allow the reports to have 1000ms due to a bug in the camera
1552 program.
1553
1554 - callisto: New swapped pixels have been found and corrected. For
1555 details see MRawRunHeader::FixAssignment()
1556
1557 - callisto: Callisto now raises an error if one of the input files could
1558 not be opened.
1559
1560 - callisto: In some rare cases it could happen that in the signal
1561 extraction of the digital filter the extractor returned nonsense
1562 results due a wrong initializion of a variable (this happens in
1563 cases in which the extracted signal is exactly zero or the
1564 digital filter couldn't slide because of a too small extraction
1565 window, which could happen in the lo-gain extraction)
1566
1567 - callisto: The lo-gains have been marked as valid in some cases
1568 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1569 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1570 smaller than the number of slices (fLoGainWindowSize) needed
1571 by the lo-gain extractor
1572
1573 - callisto: Updated absolute calibration constants (muon calibration)
1574
1575 - callisto: fixed a bug which caused the hi-gain saturation not
1576 to be handled properly in the spline (the position of the
1577 saturation was calculated incorrectly)
1578
1579 - callisto: fixed a bug which gave weird results if hi- _and_
1580 lo-gain could not be extracted properly. In some cases hi-
1581 and lo-gain have not been extracted at all and the random result
1582 got calibrated. In other cases the hi-gain was saturating and the
1583 lo-gain has not been extracted. For this a completly arbitraty
1584 scale factor was applied to the result from extracting the
1585 charge of the saturating hi-gain.
1586
1587 - callisto: improves handling of extracted signal if lo- and/or
1588 hi-gain could not be extracted properly. If no appropriate
1589 calibration of either the signal or the arrival time is possible
1590 the pixel is now markes as unsuitable instead of estimated.
1591
1592 - callisto: Fixed a problem in the spline extraction which gave
1593 weird results if the signal was extracted from the first (and
1594 highest) slice (as a workaround extraction from the first
1595 slice has been forbidden)
1596
1597 - callisto: Fixed a bug regarding the use of the QE which doesn't
1598 effect the result because the default is used anyhow.
1599 (The bug was there since 14/07/2005)
1600
1601 - callisto: Changed the default for fgLoGainStartShift to -2.4
1602
1603 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1604 factors to be always 10 for all pixels as soon as the first
1605 calibration update has happend.
1606
1607 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1608 was off by more than one slice (which gives wrong values for
1609 pixels which have saturated the hi-gain) This was a problem
1610 mainly for timing studies, not so much for the automatic standard
1611 analysis. Also the values for the Spline have been changed slightly:
1612 + Digital Filter from 1.70 to 0.95
1613 + Spline from 1.39 to 1.30
1614 The numbers were sorted out by an extensive test in the
1615 test-database.
1616
1617 - callisto: Removed the tab showing the average calibrated arrival
1618 time. It never gave useful information.
1619
1620 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1621 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1622 and both were extracted because the hi-gain was above the
1623 LoGainSwitch.
1624
1625 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1626 lo-gain pulse position (after application of LoGainOffset, which
1627 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1628 have saturated and both were extracted because the hi-gain was above
1629 the LoGainSwitch.
1630
1631 - callisto: After extensive tests a new threshold level for determination
1632 of the pulse position has been found at 50phe. This is due to the
1633 fact that for lower pulses the arrival time changes its average
1634 behaviour dramatically. It tends to the average of the extraction
1635 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1636
1637 - callisto: Added two more plots to the calibration part. The average
1638 extracted signal and the average extracted arrival time as
1639 extracted by the signal extractor (This can help debugging problems
1640 because it doesn't involve a fit)
1641
1642 - star: changed the fit for the effective on time such that initial
1643 values are calculated automatically now instead of using build
1644 in values. This makes the fit more indepedant of the underlaying
1645 rates. With a test of ~350 sequences in the test database it could
1646 be shown that the new fit gives the same result +/-1sek.
1647 The highest deviation was +5s the lowest -10s. You can now control
1648 the bahaviour with two resource values:
1649 MHEffectiveOnTime.FistBin: 3
1650 MHEffectiveOnTime.NumEvents: 12000
1651 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1652 from the resulting gamma candidates
1653
1654 - star: The Center histogram in MHHillas is now by default displayed
1655 with the colz draw-option
1656
1657 - ganymed: now produces valid error codes if failed
1658
1659 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1660 with the option "hadronness" instead of "area" or "both" if
1661 you want to use both cuts. The hadronness cut includes a fixed
1662 cut in hadronness (index 8) and a fixed cut in size (index 9).
1663
1664 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1665 the M3Long of the anti source to be not properly evaluated
1666 (actually is was evaluated as a unique random number) in case
1667 of optimization with anti-theta cut switched on. This might have
1668 lead to improper, but not necessarily wrong, optimization results.
1669
1670 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1671 how to use random forest
1672
1673 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1674 ganymed_onoff.rc. Seems to be unintentional that they were different.
1675
1676 - sponde: Since the introduction of the possibility to define a
1677 normalization energy instead of using the integral the default
1678 was not using the integral anymore but a normalization energy of
1679 1GeV. It is now the integral again.
1680
1681 - sponde: Fixed a problem in the weighting which did not allow
1682 a MC slope of -1.
1683
1684
1685
1686 *** Version 0.9.6 (2006/05/24)
1687
1688 - general: changed the binning of the azimuthal profile of the camera
1689 such that it is aligned with the 60deg boundaries.
1690
1691 - merpp: better handling of problems with the TH, TD part of the
1692 CC-REPORT for files older than 200507190 and 200412210
1693 respectively
1694
1695 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1696
1697 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1698
1699 - callisto: if an arrival time is extracted outside the fadc range is
1700 was set to the boundary before. Now a random number is assigned
1701 instead to avoid unfortunate coincidences of arrival times just
1702 by this arbitrary value.
1703
1704 - callisto: added a new option to callisto.rc which allows
1705 to set the maximum arrival time difference allowed for the
1706 badpixel algorithm to determin whether a pixels belongs to a shower:
1707 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1708
1709 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1710 to 0.9 as suggested by Stefan due to a recent study on the fraction
1711 of pixels surviving the image cleaning
1712
1713 - callisto: switched off error in case of "pulse is too much to the left"
1714
1715 - callisto: The extraction window is not adapted anymore. This means that
1716 the pulse is extracted from the full range. The draw-back is that the
1717 background (pedestal) will become slightly higher. Switching on/off
1718 the PulsePosCheck in the callisto.rc only effects filling the
1719 histograms.
1720 WARNING: If the pulse is too much to the left data is calibrated!
1721 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1722 in the database to make sure that your data is valid!
1723
1724 - star: Show also the number of stars correlated correctly by the
1725 starguider
1726
1727 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1728 than one off-source region in wobble-mode. To use it add the following to
1729 your ganymed_wobble.rc:
1730 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1731 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1732 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1733 + Cut1.ThetaCut: None
1734 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1735
1736 - ganymed: in the case the latest report is older than a default (currently
1737 one minute) and the current report will be skip the starguider
1738 correction and calibration will be reset. The maximum age can be
1739 setup from ganymed.rc by (minutes):
1740 MPointingDevCalc.MaxAge: 1.5
1741
1742 - ganymed: A first implementation showing all size-bins for the theta-sq
1743 resp. alpha-plots in a single tab automatically
1744
1745
1746
1747 *** Version 0.9.5.1 (2006/05/05)
1748
1749 - general: Added a new option "zdiff" to the Makefile which runs
1750 "cvs diff" as "make diff" would do, but with compression
1751
1752 - general: accelerated MTFillMatrix (used for eample in all training
1753 and optimization macros) by skipping some obsolete calles in the
1754 eventloop the first and second loop could be accelerated by ~20%
1755
1756 - general: Added a missing feature in the MFilterList class which
1757 prevented MFEnergySlope from working correctly in trainenergy.C
1758
1759 - general: Accelerated the random forest training and usage a bit
1760
1761 - merpp: Adapted to new raw data file format version 6
1762
1763 - merpp: fixed a problem with reading the starguider reports
1764 after 6.3.2006
1765
1766 - callisto: At some times six pixels had to be exchanged manually in the
1767 data. If the pixels to be swaped are both not found, an error was raised
1768 and calibration was stopped. Now it is assumed they are intentially not
1769 mapped and the Error has been changed to a Warning.
1770
1771 - star: Added new image cleaning based on the arrival time of the shower.
1772 The new cleaning can be accessed using the parameter "Time" instead of
1773 the the old one (like "Absolute) in the star.rc-file.
1774 Recommended parameters:
1775 + MImgCleanStd.CleanLevel1: 8.2
1776 + MImgCleanStd.CleanLevel2: 5
1777 + MImgCleanStd.CleanRings: 2
1778 + MImgCleanStd.KeepSinglePixels: No
1779
1780 - star: Simplified the calculation of the effective on time. By letting
1781 the fit start in the third bin the result should become more stable.
1782 The fit quality is now ignored for the theta-plot which is not used
1783 in the analysis later. Still better pre-cut which, for example,
1784 remove events triggered by car-light (rate changing on a short
1785 time-scale) are missing.
1786
1787 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1788 for optimization (kWeakSource) which is suggested by the Berlin
1789 people for weak sources.
1790
1791 - macros: plotdb.C:
1792 + if no dataset and no time-interval is given only sequences with
1793 an effective on-time above five minutes are plotted anymore
1794 + added a new tab "RelTime" displaying the relative on-time
1795 (effective on-time divided by the observation time)
1796
1797 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1798 the optimization became a lot faster
1799
1800 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1801 To display them just delete the pads displayed on top.
1802
1803 - ganymed: fixed a bug which could cause strange behaviour in wobble
1804 mode if no starguider information was available due to an incorrect
1805 initialization of the starguider calibration
1806
1807 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1808 be changed from within the plot. It can also be setup from the
1809 resource file using:
1810 + MHDisp.fScaleMin: 0.325
1811 + MHDisp.fScaleMax: 0.475
1812
1813 - ganymed, showplot: Fixed a problem with the fit to the off-data
1814 (HistOff) which could cause a time lag or an inifinite loop.
1815 The bug did not effect the results at all.
1816
1817 - sponde: Added a new tab showing the effective collection area after
1818 trigger (including the software trigger)
1819
1820 - sponde: MMcSpectrumWeight has a new option which allows to define
1821 the scaling factor not by the integral of the events but at
1822 a defined energy:
1823 e.g. MMcSpectrumWeight.NormEnergy: 200
1824
1825 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1826 eventloops the loop could be accelerated by ~20%
1827
1828
1829
1830 *** Version 0.9.5 (2006/03/13)
1831
1832 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1833 and added the standard Disp-parametrization
1834
1835 - macros: added a new macro datacenter/macros/plotstat.C allowing
1836 to plot statistics about the data processing
1837
1838 - macros: added a new macro to plot the muon correction coefficients
1839 versus period (macros/plot/mucal.C)
1840
1841 - showplot: path inflation for ganymed files was broken
1842
1843 - callisto: Fixed an important bug. When the number of saturating pixels
1844 were calculated the bad pixel information already available from the
1845 calibration was ignored. This yields wrong values in case pixels
1846 are broken and saturate all the time or randomly.
1847
1848 - callisto: Updated Muon calibration constants. Spline data now also uses
1849 different values for different periods
1850
1851 - star: The time-evolution shown in the effective on-time plot now displays
1852 the axis range (if there are no holes it should be similar to the
1853 effective on-time)
1854
1855 - star: Added two new image parameters:
1856 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1857 the three pixels next to the center of gravity and the size
1858 + MNewImagePar.fConcCore: The ratio of the signals of all
1859 pixels inside or touching the ellipse and the size
1860
1861 - ganymed: now stops in requested source isn't found in catalog file
1862
1863 - ganymed: Many improvements to the phi-plot in wobble mode:
1864 + with a template the ideal background is displayed
1865 + a possible camera inhomogeneity is taken into account
1866 + the anti theta cut is better supported
1867 + the phi cut is automatically calculated from the theta cut
1868 See the examples in ganymed_wobble.rc for more details.
1869
1870 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1871 times the bin-width instead of the absolute energy
1872
1873 - ganymed: New cuts for on/off and wobble mode
1874
1875 - ganymed: The smearing of the False Source plot has been increased
1876 to 0.06
1877
1878 - ganymed: The starguider calibration can now be changed from the
1879 resource file.
1880 See the examples in ganymed*.rc for more details.
1881
1882 - ganymed: added a new option for on-/off-observations
1883 MJCut.RandomSourcePosition
1884 If switched on the distribution of observation time of the source
1885 position in the camera is calculated from the on-data and randomly
1886 applied with this distrbution to the off-data.
1887
1888 - ganymed: by skipping some obsolete calles in the eventloop the
1889 first and second loop could be accelerated by ~20%
1890
1891 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1892 position in the off-data randomly according to its distribution in the
1893 on-data.
1894
1895
1896
1897 *** Version 0.9.4.3 (2006/02/13)
1898
1899 - general: Fixed a bug in most of the programs which prevented the
1900 compile date in the startup message to be displayed
1901
1902 - general: Simplified program calls. The following abbreviations
1903 are now possible:
1904 showlog callisto 55599
1905 showplot signal 55599
1906 star 55599
1907 callisto 55999
1908 ganymed 2
1909 In this cases the corrsponding root-, log-, sequence- or dataset-
1910 filename is automatically compiled using the default datacenter
1911 paths ("/magic/*")
1912
1913 - general: Fixed a long outstanding bug which made axis tick marks
1914 disappear if MDataFormula was used (eg. abs(x))
1915
1916 - general: Updated MMath with new functions to calculate the results of
1917 a exponential, logarithmic and powerlaw fits analytically.
1918
1919 - general: Updated some macros with comments:
1920 + macros/optim/optimdisp.C
1921 + macros/optim/optimenergy.C
1922 + macros/optim/optimwobble.C:
1923
1924 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1925 files) now allows adding a pre-cut like in the optimization. E.g. this
1926 is useful to perform g/h-separation cuts before training the random
1927 forest.
1928
1929 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1930 correctly assigned in the raw data assignement table. A fix to correct
1931 the assignment tabel have been implemented.
1932
1933 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1934 by 90, 180 and 270 deg.
1935
1936 - general: the macro plotdb.C now allows to highlight sequences belonging
1937 to a datset. For more details see the descritions in the macro.
1938
1939 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1940 of the display, it gave wrong results espacially for big sizes.
1941 Now the embedded canvas should always have a ratio width/height=3/2.
1942 The "Size" options have been updated with values fitting the 3/2
1943 size ratio.
1944
1945 - RanForest:
1946 + Updated the random forest classes to support also the
1947 regression method implemented by Thomas H.
1948 + added new tutorial macro how to train the random forest
1949 for energy estimation (macros/optim/rfenergyest.C)
1950 + new classes to train the random forest (still in development)
1951 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1952 + new tutorial macros for random forest training in macros/train
1953 trainenergy.C, traindisp.C, trainseparation.C
1954
1955 - mars: now allows to setup a cut in the resource file mars.rc to choose
1956 the events to be displayed, eg:
1957 Cut.Condition: {0} && {1}
1958 Cut.0: MHillas.fSize>100
1959 Cut.1: MHillas.fSize<900
1960
1961 - merpp: Made aware of the new .rep format 200510250. This includes
1962 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1963 the discriminator thresholds (MCameraTD) and the disciminator
1964 delays (MCameraTD). All of them come with the CC report and are therefor
1965 written to the CC tree.
1966
1967 - callisto: fixed a bug in the calculation of the arrival times in
1968 the Digital Filter. They were all shifted by the same amount
1969 fHiGainFirst. This caused an offset in the order of the position of
1970 the left border of the extraction window in the times calculated
1971 from high-gain and from low-gain. The bug effected only the absolute
1972 arrival times. The bug was there since 30.1.2005.
1973
1974 - callisto: Changed the ExtractionWindow for the pulse position check
1975 such that the camera inhomogeneity becomes as less as possible and
1976 comparable to the pulso position check switched off. More details
1977 on the study will be given at our result web-page.
1978
1979 - ganymed: ganymed.rc, ganymed_onoff.rc:
1980 changed to new cuts trained with 1ES1218 and Crab-data
1981 for maximum sigma*log10(excess)
1982
1983 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1984 a new option was implemented to estimate Disp (CalcDisp)
1985
1986 - ganymed: Implemented two new options which allow
1987 to overwrite the default path to search for the sequence files
1988 --ins=/magic/sequences
1989 and where to search for the image data
1990 --ind=/magic/data/star
1991
1992 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1993 dx/dy from the resource file by
1994 MSrcPosCorrect.Dx
1995 MSrcPosCorrect.Dy
1996
1997 - ganymed: fixed reading the source catalog. Only as many chars
1998 as the requested source name had were compared (If a source
1999 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
2000 were requested it could happen that the coordinates of
2001 "1ES1218" were read) The source coordinates are now printed
2002 in addition to its name to the logging output.
2003
2004 - ganymed: changed the background fit in the case of a ThetaSq function
2005 from a polynomial to a exponential, this should give a big improvement
2006 for on-only analysis'
2007
2008 - ganymed/sponde: Calculation of the error of single size-/energy-
2009 bins now uses Li/Ma (5) instead of LiMa (17)
2010
2011 - sponde: Added a plot E^2*dN/dE
2012
2013 - sponde: The energy estimator plot should now show values like
2014 they are commonly used.
2015
2016 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
2017 (a powerlaw with cutoff didn't work before)
2018
2019
2020
2021 *** Version 0.9.4.2 (2005/10/01)
2022
2023 - general: added new tutorial macro macros/tutorials/threshold.C:
2024 how to calculate the threshold
2025
2026 - general: added a new game. Start it from the interpreter with
2027 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
2028 and MagicReversi)
2029
2030 - general: neighbor pixels in MGeoms are now sorted clockwise
2031
2032 - merpp: made aware of new format 20050829-0
2033
2034 - callisto: New scale factors from muon analysis, stored in new
2035 resource file resources/calibration.rc
2036
2037 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
2038 the eventloop if something went wrong. This is necessary for the
2039 automatic processing
2040
2041 - callisto: Implemented a new treatment for the time information
2042 developed by S.Ruegamer, this should give much better response than
2043 the old very primitive algorithm. This is especially important
2044 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
2045 treatment was buggy! As neighbor pixels to interpolate the
2046 arrival times always the pixels 0 to 5 were taken)
2047
2048 - callisto: In addition to the new treatment of arrival times the
2049 decision of the treatment whether a pixel contains shower
2050 information or not is used to improve the signal interpolation
2051 further. Previously interpolated pixels showed a non-zero signal
2052 do the peak searching signal extractors. Having a signal pixel
2053 beside raised the signal above the cleaning level. Thus the
2054 pixel survived cleaning to often but with a too low mean signal.
2055 By replacing empty pixels with a gaus (mean and rms from the
2056 corresponding Area entries in MPedPhotCam) this effect can
2057 be supressed.
2058
2059 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
2060 got lost when the events were stored by the calibration... fixed.
2061 (This was no problem for normal image cleaning because the pixel
2062 content was artificially set to 0 not surviving standard cleaning
2063 algorithm)
2064
2065 - callisto: Fixed a bug which caused the random and peak-search pedestal
2066 extracted with an extractor to be exchanged for the first (roughly)
2067 500 events (*Extractor and *ExtractorRndm).
2068 (They were simply exchanged in callisto.cc) This bug might have been
2069 introduced in Mars 0.9.4 when the order of calculation of the two
2070 types of pedestal in callisto got exchanged. The bug only effects
2071 the first seconds of data of each sequence.
2072
2073 - star: Taking the arrival time of Muons into account the calculation
2074 of the parameters could be made independant of the noise
2075 (pedestal rms). The dependance was due to the bias of the peak search
2076 extractor. Now only a ZA dependamcy is left which is not yet fully
2077 understood.
2078
2079 - ganymed: The sequences were still not sorted correctly in any case,
2080 because they were sorted by the full qualified path name. Now they
2081 are sorted by their sequence number.
2082
2083 - ganymed: new values for the spark-event-cut
2084
2085 - sponde: required missing MEnergyEst from ganymed.root... fixed.
2086
2087
2088
2089 *** Version 0.9.4.1 (2005/08/18)
2090
2091 - callisto: fixed some problems with the calibration in case of
2092 inteleaved events. Therefor the final and some intermediate
2093 fits are skipped which would take place on partly filled #
2094 histograms and gave wrong results or failed completely.
2095
2096 - callisto: If the intermediate finalization of the histograms
2097 calculating the mean charge of the calibration signal fails
2098 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2099
2100 - ganymed: Fixed some bugs which caused problems in On-only mode.
2101 Still the false source plot doesn't give reasonable results.
2102
2103
2104
2105 *** Version 0.9.4 (2005/08/05)
2106
2107 - general: Fixed the ZA binning. It did not correctly fit the
2108 MC binning
2109
2110 - general: Added a class to correct for the missfocussing in
2111 April (MSrcPosCorrect)
2112
2113 - general: Random Forest energy estimator should now work properly
2114
2115 - general: MHCamera now displays the profiles in deg instead of mm
2116
2117 - general: MH::SetPalette offers a lot of new palettes
2118
2119 - general: MHillas - the case of CorrXY==0 is now handled properly
2120
2121 - general: implemented the possibility to change the line and
2122 marker style of a sky-grid drawn by MAstroCatalog
2123
2124 - general: Runs in sequences and datasets are now automatically
2125 ordered (it is assumed that the order of their filenames correctly
2126 represents the order of observations) to ensure correct reading
2127 of the subsystem data
2128
2129 - general: Runs cannot be added to a sequence twice anymore. Also
2130 Sequences cannot be added twice anymore to a dataset.
2131
2132 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2133 It gave wrong results by 1./2pi
2134
2135 - showplot: got a new option to start a root interpreter, too
2136
2137 - mars: now displays a rough estimate of Disp and the third moment
2138
2139 - mars: now displays the event time MTime if available
2140
2141 - mars: show muon parameters graphically
2142
2143 - mars: now the file to open can be given as commandline
2144 argument
2145
2146 - merpp: Added support for new arehucas version >= 200507190
2147 implementing values for three temperature sensors in the
2148 counting house (MCameraAUX) and the name of the HV settings file
2149 (MCameraHV).
2150
2151 - merrp: Also fixed some problems with wrong versions numbers stated
2152 by arehucas and implemented some fixed for old versions (<200407070)
2153
2154 - callisto: MCalibrationHiLoCam can now be printed from its context
2155 menu, eg in the TBrowser
2156
2157 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2158 - 1.39 (MExtractTimeAndChargeSpline)
2159 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2160 This is important mainly for timing studies.
2161
2162 - callisto: Changed limits in MHCalibrationChargeCalc from
2163 - -100.125 to -98 (fgChargeHiGainFirst)
2164 - 1899.875 to 1902. (fgChargeHiGainLast)
2165 - -100.25 to -99 (fgChargeLoGainFirst)
2166 - 899.75 to 901. (fgChargeLoGainLast)
2167 Introduced new limits:
2168 - fgNumLoGainBlackoutLimit: 0.05
2169 - fgLoGainBlackoutLimit: 3.5
2170 - fgLoGainPickupLimit: 3.5
2171
2172 - callisto: The handling of automatic weights for the digital filter
2173 has been improved. There are now new calibration weights special
2174 for Monte Carlo calibrations.
2175
2176 - callisto: Updated Muon scale with latest results (1% difference
2177 for most data, 5% for Mar/Apr'05)
2178
2179 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2180 was saturated and the blackout-events in the low-gain exceed the
2181 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2182 This excludes those pixels which have a saturating high-gain
2183 channel, but the low-gain switch does not switch often enough
2184 to make the distribution reliable.
2185
2186 - callisto: fix a bug counting the number of saturated events. Up to now,
2187 the number of saturated slices was counted (which is one for a not too
2188 high number), but for some (pathological) pixels, many more slices
2189 saturated and produced wrong limits.
2190
2191 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2192 + MCalibrationRelTimeCam.CheckFitResults: Yes
2193 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2194 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2195 + MCalibrationRelTimeCam.CheckOscillations: Yes
2196
2197 - callisto: introduce max. number of events for intercalibration,
2198 the rest gets skipped. Default: 4096
2199 The calibration causes too many un-reliable pixels if more
2200 than about 5000 events are treated (@500 Hz) because of the
2201 mode hopping of the VCSels. However, in the past, some
2202 calibration runs have been taken (erroneously) with more
2203 than 5000 events, especially the intensity scans where
2204 a good precision is needed.
2205
2206 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2207 photo-electrons for the spline extractor by 1-2% (correctly).
2208
2209 - callisto: The intercalibration is now done using a full f-factor
2210 method instead of a simple update. This makes things slower but
2211 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2212 changes.
2213
2214 - callisto: MPedestalY3 now uses the same extraction range as the data
2215 as calculated by MPedestalY2
2216
2217 - callisto: A check of the fraction of allowed unsuitable (10%) and
2218 unreliable (30%) pixels has been addded when the conversion is
2219 calculated from interleaved events
2220
2221 - star: fixed a bug which caused MEffectiveOnTime containers not to
2222 be written. In the worst case they were skipped almost all, in the
2223 best case they were all ok. It depends on how often the new value
2224 was assigned just with an event which was skipped later by another
2225 task
2226
2227 - star: new histograms MHPointing and MHRate
2228
2229 - star: New tab (Currents) displaying the time evolution of the mean
2230 DC currents
2231
2232 - star: New tab (MeanRms) displaying the time volution of the mean
2233 Pedestal Rms
2234
2235 - star: Output now contains MReportStarguider
2236
2237 - star: Improved muon analysis. Due to the absense of a constant
2238 for the gaus fit for arc width and the fact that the arcwidth
2239 plot was a histogram instead of a profile the resulting psf
2240 became pedestal rms dependant
2241
2242 - ganymed: added new plot (MHPhi) for wobble mode as described in
2243 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2244
2245 - ganymed: corrects now (correctly?) for the misspointing in
2246 May/April 05
2247
2248 - ganymed: Two new default templates for ganymed.rc are avilable:
2249 ganymed_onoff.rc and ganymed_wobble.rc
2250
2251 - ganymed: The first version of MFMagicCuts has been released
2252
2253 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2254
2255 - ganymed, sponde: There are two new options to determin the number
2256 of bins for the signal region (NumBinsSignal) and the number of
2257 total bins (NumBinsTotal) in the MHThetaSq histogram
2258
2259 - ganymed: optimized palettes for MHDisp
2260
2261 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2262 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2263 sqrt(2) to large
2264
2265 - ganymed: The false source plot (MHDisp) is now based on Disp
2266 and a background model determined in the first loop is
2267 subtracted
2268
2269 - ganymed: MFMagicCuts are now available in the cvs. The correct
2270 solution for the disp ambiguity problem is now calculated using
2271 the third moment. The third moment cut therefor is skipped.
2272
2273 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2274 already determined by the third moment along the major axis and
2275 so its actual sign is aligned along the major axis of the shower.
2276
2277 - ganymed: If starguider data is available it is taken into account
2278 when calculating the source position. This is especially important
2279 for wobble data at high zenith angles and culmination data.
2280
2281 - ganymed: If available the starguider data is taken into account as
2282 good as it is possible without a starguider calibration. To switch
2283 it off add
2284 MPointingDevCalc.MaxAbsDev: -1
2285 to your ganymed.rc
2286
2287 - sponde: the zenith angle distribution is now weighted instead of
2288 choosen by default. This gurantees higher statistics in the highest
2289 and lowest energy bins. To switch this behaviour off use...
2290
2291 - sponde: now automatically displays the energy threshold
2292
2293
2294
2295 *** Version 0.9.3 (2005/06/03)
2296
2297 - general: MMcEvt now derived from MMcEvtBasic which should
2298 have no influence on compatibility with older camera files
2299
2300 - general: Implemented a new option to MReadReports which allows
2301 to force reading of the first event of some trees (eg. Drive-tree)
2302 before any other tree.
2303
2304 - general: Made a fix to MPointingPosCalc which assumes that the
2305 run-type is real-data if Process is called before ReInit, such
2306 that also the very first Drive-events in a run are treated
2307 correctly.
2308
2309 - shoplot now displays the filename in the title bar of the window
2310
2311 - merpp: new options: --auto-time-start --auto-time-stop which
2312 allow to cut updating with slow-control at the start- or
2313 (previousle --auto-time only allowed: and) stop-time of
2314 the run stored in the runheader.
2315
2316 - callisto: changed default of fgFallTimeHiGain in
2317 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2318 already set as default in callisto_Dec04Jan05.rc
2319
2320 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2321 now changes the filename for new weights automatically for
2322 cosmics, MC and for different calibration colors.
2323
2324 - callisto: a problem with the order of some code cause the
2325 name of the weights file in MPedestalY2 to be ignored.
2326 Wrongly the calibration_UV weights were used instead
2327 of the cosmics weights set in callisto.rc.
2328
2329 - callisto: should allow ct1 pulser data when the color is
2330 explicitly set also for pretty new runs
2331
2332 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2333 to introduce an additional scale factor (should be around 1)
2334 to adapt for slight deviations in different extractors from
2335 the MC calibration. For MC calibrations the scale factor
2336 is fixed to 1
2337
2338 - callisto: MFCosmics should handle very high signals a bit
2339 more accurate now
2340
2341 - callisto: when calculating the mean pedestal rms for different
2342 pixel sizes or sectors also kUnsuitableEvt is now taken into
2343 account - not only kUnsuitableRun
2344
2345 - callisto: '-raw' option is now the default
2346
2347 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2348 This has the advantage that mean values in the calibration (eg
2349 arrival times) are calculated more accuratly.
2350
2351 - callisto: In the resource file callisto_Dec04Jan05.rc
2352 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2353
2354 - callisto: new Hi-/Lo-Gain intercalibration constants
2355 hilocalib_sp1.root and hilocalib_sp1_mc.root
2356
2357 - callisto: changed default for MJPedestalY2.MaxEvents
2358 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2359
2360 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2361 has changed from 9.0 to 6.0. This is necessary to exclude two very
2362 ringing pixels in September which - when kept - destroy the image
2363 cleaning around them (Markus G.)
2364
2365 - callisto: (!) The Muon analysis of all data taken so far has
2366 suggested that different extractors give slightly different
2367 absolute results after calibration, due to there different
2368 handling of the calibration- and cosmics pulse shape. Although
2369 the over all calibration seems to be a bit to pesimistic (or
2370 the MC seems to be a little bit - 3-5% - too much attenuated).
2371 There for correction factors have been introduced which correct
2372 the calibration constants by
2373 0.956937799 for Digital Filter (callisto.rc)
2374 and
2375 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2376 calibration. The main advantage is, that both data types can
2377 be easily analysed together and compared to the same MC sample.
2378 The factors are choosen such, that the reference is now a
2379 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2380
2381 - star: fixed a bug which caused the first bin of the histograms
2382 vs time to disapear in PostProcess. This gave wrong results
2383 on the screen. The output and all following programs not
2384 directly accessing the histograms haven't been affected
2385
2386 - star, ganymed: Made sure that always the first Drive-tree event
2387 is read and Processed before the first data event was read.
2388
2389 - ganymed: implemented the possibility to replace the standard
2390 false source plot with a different one. For example: If
2391 you want to use a Disp based FS plot use the resource:
2392 NameHistFS: MHDisp
2393 For details about the requirements of these plots look
2394 at the corresponding classes
2395
2396 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2397 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2398 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2399 case MAlphaFitter is setup correctly. For On-Only optimization
2400 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2401 RunOn() instead of Run(). For energy estimation MJOptimize
2402 has been replaced by MJOptimizeEnergy
2403
2404 - sponde: The input MC spectrum can now be weighted to fake a
2405 different spectrum. This is done via MMcSpectrumWeight. For
2406 more details see the class description and sponde.rc
2407
2408 - sponde: The paremeter comparsion plots are not scaled by
2409 their entries anymore. Instead the MC plot is scaled by using
2410 the result spectrum of the analysis. If the input MC spectrum
2411 and the result spectrum has different slopes the absolut
2412 normalization is normally wrong.
2413
2414
2415
2416 *** Version 0.9.2 (2005/05/20)
2417
2418 - general: Changed the default paths for calibrated data and image
2419 files. (The implemented access to these files doesn't yet exist)
2420
2421 - general: support for MRunIter has been removed from the job classes
2422 (use the setter functions of MSeqeunce instead)
2423
2424 - general: ProcessFile has been renamed to Process in all job classes,
2425 because ProcessFile is missleading
2426
2427 - general: The storage of the palette in MHCamera is now possible
2428
2429 - general: new bits describing unsuitable and unreliable pixels have
2430 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2431 kDeadPedestalRms, kFluctuatingArrivalTimes
2432
2433 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2434 versions newer than V200404070
2435
2436 - general: support for cc file versions newer than V200504130. Added
2437 support for active loads (MCameraActiveLoad) and central pixel
2438 (MCameraCentralPixel)
2439
2440 - general: added new histograms for image parameters versus size
2441 (MHVsSize)
2442
2443 - general: The eventloop now automatically calls PrintStatistics
2444
2445 - Status Display: Improved support for printing:
2446 + A default can now be set in .rootrc (for more details see
2447 MStatusDisplay::PrintPS)
2448 + A print dialog is opened so that printer and command line
2449 can be canged
2450
2451 - showlog: improved such that it handles different verbosity levels
2452 more accurate now. This mean you can suppress output when
2453 using showlog.
2454
2455 - showplot: improved
2456 + The new graphics formats have been implemented
2457 (pdf, svg, png, jpg and xpm)
2458 + Implemented an interface for printing. Because you can change
2459 the printing command from the command line you can use all
2460 the nice postscript tool. To print a booklet for example call:
2461 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2462 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2463 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2464
2465 - callisto: fixed a bug in the recognition of the calibration bit
2466 pattern. Concerns only intensity calibration. (The strength of the
2467 intensity has been updated in some cases)
2468
2469 - callisto: add a filter against PIN Diode events when running over
2470 calibration runs since some of the recent calibration runs have
2471 been taken with Pin Diode.
2472
2473 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2474 39943, 44833 in the calibration (MCalibColorSet)
2475
2476 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2477 been set to 1e-18 in callisto_Dec04_Jan05.rc
2478
2479 - callisto: in callisto_Dec04Jan05.rc: set value for
2480 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2481 statistics for the calculation of the mean pulse time
2482 of the cosmisc
2483
2484 - callisto: the charge limit in the calibration has been raised
2485 from 2.5 to 4.5
2486
2487 - callisto: new setup read from callisto.rc
2488 + MCalibCalcFromPast.fNumEventsDump
2489 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2490 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2491
2492 - callisto: MExtractTimeAndChargeSpline extractor:
2493 + The integration ranges were shifted by 0.2 FADC slices to the right.
2494 + unreliable handling of floating point values caused different
2495 results on different platform or with different compiler options:
2496 The new algorithm is numerically exact and more accurate because
2497 it doesn't calculate the integration position by multiple times
2498 adding the step-size (which results in numerical uncertanties
2499 exspecially if multiplied with large numbers)
2500 + A lot of fixes have been introduced which effects integrating the
2501 spline at the edges of the valid range. In this case any memory
2502 was randomly accessed. This behaviour can be tested replacing
2503 all MArrayF by TArrayF which perform a range check (but of course
2504 they are a lot slower)
2505 ! No result obtained with the Spline before can be trusted! Due to
2506 random memory access it might by completely random!
2507
2508 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2509 + extraction range in the high gain to 4.
2510 + weights file to cosmics_weights46.dat
2511
2512 - callisto:
2513 + introduce the check for fluctuating arrival times.
2514 + set charge limit to from 2.5 to 4.5
2515 + introduce asymmetric exclusion due to "deviating number of phes":
2516 Default: -9.0 +4.5
2517 + make deviating number of phes unsuitable (see David's findings).
2518
2519 - callisto: fixed the display of unsuitable pixels. The old change
2520 to a real profile in MHCamera broke it.
2521
2522 - callisto: The cosmics filter is used in MJCalibration now
2523 independant of the pulser color (formaly it was used only for
2524 CT1-pulser data). The threshold of number of max empty pixels
2525 has been raised from 2% to 5% in MJCalibration. The maximum
2526 fraction of rejected event is 50% otherwise the calibration has
2527 failed. The filter now ignores unsuitable pixels.
2528 Setup the filter from callisto.rc using "ContCosmics"
2529 (see MFCosmics::ReadEnv)
2530
2531 - callisto: changed default for fgOffsetFromLogain back
2532 from -2.8 to -1.8 in digital filter.
2533
2534 - callisto: for the common extractors
2535 + MExtractFixedWindow
2536 * MExtractTimeAndChargeSlidingWindow
2537 * MExtractTimeAndChargeSpline
2538 * MExtractTimeAndChargeDigitalFilter
2539 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2540 and fResolutionPerPheLoGain
2541
2542 - callisto: Updated the hi-/lo-gain intercalibration constants
2543 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2544 hilocalib_df6.root
2545
2546 - callisto: The default lo-gain extraction window for the
2547 MExtractTimeAndChargeSlidingWindow extractor has been increased
2548 from 6 to 8 to take the stretch of the pusle into account
2549
2550 - callisto (!!!): fixed an important bug in the setting of the
2551 incoming pedestal pointer to the signal extractor extracting
2552 pedestals. This bug caused the pedestals not to be subtracted
2553 correctly in the calibration afterwards. The effect was about 10%
2554 too high conversion factors for the digital filter and the spline
2555 and more than 40% for the sliding window.
2556 The bug existed since end of February! (Markus G.)
2557
2558 - star: added muon support to star. A new tab "MHMuonPar" is
2559 displayed. The lower right plot is an estimate of the point spread
2560 function. A reference value is displayed. To get the real PSF
2561 you must compare with MC. The setup for the muon analysis
2562 is done in star.rc. More informations can be found in
2563 MHSingleMuon and MHCalibParCalc
2564
2565 - star: The weather data is now displayed in star
2566
2567 - star: MEventRateCalc handles the calculation of the event rate more
2568 accurate now in case of the start of a new run inside a sequence
2569
2570 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2571 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2572 changed only minimally
2573
2574 - ganymed: (MJCut and MJOptimize) now displayes the number of
2575 excess events versus size. The energy estimation is done in
2576 MJSpectrum (sponde)
2577
2578 - ganymed: got support for using other variables than Alpha, eg. Theta.
2579 Therefor you need a class deriving from MHAlpha which supports
2580 this variable (one is already existing: MHTheta, which is now the
2581 default in ganymed). It is setup through ganymed.rc
2582
2583 - added a full featured spectrum program (sponde) which reads
2584 ganymed output and monte carlos and compiles a spectrum
2585
2586
2587
2588 *** Version 0.9.1 (2005/04/14)
2589
2590 - Fix bug on the arrival time reconstruction when using Digital
2591 Filter (in some marginal cases (10%) times were reconstructed shifted
2592 by 0.2 slices)
2593
2594 - all executables now return 2 where in previous versions -1 has
2595 been returned (gave problems with shell-scripts)
2596
2597 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2598 also done with a intercalibration input file
2599
2600 - a bug in the time fine adjustment of the digital filter has been fixed
2601
2602 - a lot of small fixes to calling TPad::Divide with a margin==0
2603
2604 - MStatusDisplay now shows the memory usage
2605
2606 - added a memory leak statistic after the eventloop
2607
2608 - MHadronness replaced by MParameterD
2609
2610 - MEnergyEst replaced by MParameterD
2611
2612 - wobble mode can now be switched on from the data-set
2613
2614 - switched on bad pixel detection for a pedestal level
2615 which is more than 5 times the variance
2616
2617 - Fixed default paths to be correct for the new data center
2618
2619 - Fixed handling of drive data. The pointing position in now
2620 copied to MPointingPos inside star for real and MC events
2621
2622 - made sure, that the sequences in a dataset are sorted by
2623 their number to ensure the correct synchronization
2624
2625 - added all resource files necessary to handle spline extraction
2626 of signal for the late 2004 and the early 2005 data
2627
2628 - update the reference lines for the december data
2629
2630 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2631 This is important for the Dec. and Jan. data where the calibration
2632 pulse position changes much.
2633
2634 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2635 filter. This corrects only an defective extraction of the MC at
2636 low-gain signals lower than 90 phes.
2637
2638 - fixed some slowdown in calibrating data with interleaved events from
2639 Jan and Dec. As a workaround made the pretty palette the default.
2640 The inverse Deep Blue Sea has a bug which slows down long calibration
2641 runs a lot.
2642
2643 - implemented new values from new starguider report as defined
2644 in TDAS00-07 V7.1 (eg SkyBrighness)
2645
2646 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2647 in starguider report (If you merpp the same reports with this version
2648 you'll get the correct units (arcmin) but a different result
2649 than with old versions (wrong units))
2650
2651 - Now the status display can also write PNG, JPEG and XPM (other file
2652 formats are still unsupported by root)
2653
2654 - added a lot of scripts and macros in directory datacenter used
2655 for automatic processing
2656
2657
2658
2659 *** Version 0.9 (2005/03/23)
2660
2661 - Calibration is now done autmatically into photo-electrons like
2662 decided by the Collaboration Board
2663
2664 - Reference lines in the display can be read from resource file
2665
2666 - Interlaced calibration events can be handled by callisto
2667
2668 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2669 and applied in callisto.
2670
2671 - class MJCalibTest can be called by callisto
2672
2673 - callisto can now run with three data types: rawdata, rootdata, MC
2674
2675 - added two classes mreport/MReportStarguider.cc and
2676 mreport/MReportStarguider.h for implementing starguider-data
2677
2678 - the output of merpp-update now contains starguider information:
2679 MReportStarguider and MTimeStarguider
2680
2681 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2682 values were lower than they should. This was more visible for high
2683 energy (Size) events.
2684
2685 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2686
2687 - added a new loop to callisto to support the correct extraction of
2688 the pedestal and pedestal rms through the signal extractor
2689
2690 - added class to perform fourier tranformation of a hexagonal structure
2691 (MHexagonalFT)
2692
2693 - added class to perform fourier tranformation of a hexagonal structure
2694 in a tasklist (MHexagonalFTCalc) example: hft.C
2695
2696 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2697 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2698 small pixels, example: extendcam.C
2699
2700 - added possibility to write data to memory (TTree) using MWriteRootFile
2701
2702 - added possibility to read a TTree stored only in memory by MReadTree
2703
2704 - new classes to deal with the interleaved calibration events:
2705 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2706
2707 - implemented filters to callisto to skip calibration events
2708
2709 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2710 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2711 the slices by statistics
2712 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2713 signal extractor without randomization
2714 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2715 with the signal extractor with randomization (extraction window is
2716 randomly fixed)
2717 The three kind of pedestal is not yet implemented (for speed reasons) as
2718 long as nobody really needs it:
2719 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2720 extracted with the signal extractor with randomization
2721
2722 - callisto now finds the pulse position in the data automatically
2723
2724 - implemented data reduction in calibrated data by reducing the precision
2725 of the stored floating point values (pedestal, rms and signal) to
2726 roughly 0.5%
2727
2728 - fixed showplot to make file format conversion (eg. converting a
2729 status display stored in a root file into a postscript file) in
2730 batch mode possible:
2731 showplot -b --save-as-ps[=outfile.ps] infile.root
2732
2733 - Allow class names as part of filter rules, eg
2734 (MFSupercuts) && (MHillas.fSize>100)
2735
2736 - fixed a lot of stuff to allow all programs to process MonteCarlo
2737 camera files.
2738
2739 - enhanced possibility to debug reading of resource file
2740
2741 - MDataChain should handle priorities of operator more
2742 accurate now
2743
2744 - completely revised the container in which the signal is stored
2745 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2746 * the new implementation is faster and
2747 * needs less storage space
2748
2749 - FIRST version which can process Monte Carlos through the
2750 whole chain of programs (callisto, star, etc)
2751
2752 - implemented new image parameters for the border length of
2753 the shower image (MNewImagePar2)
2754
2755 - implemented wobble-mode in ganymed
2756
2757 - new class (MJOptimize) taking care of all optimization processes
2758
2759
2760
2761 *** Version 0.8.6 (2004/10/05)
2762
2763 - New combined signal and time extractor
2764 MExtractTimeAndChargeDigitalFilter
2765
2766 - The Report for the trigger section in the CC run summary has been
2767 updated, and now the IPRs (Individual Pixel Rates) are available.
2768
2769 - new macros for database interaction: filldotrun.C, filldotrbk.C
2770
2771 - added new program which can convert colored output which was redirected
2772 into a file back into colored text (for example to display it with
2773 more): showlog
2774
2775 - added new program to display an MStatusArray of plots (stored with
2776 MStatusDisplay) from a file: showplot
2777
2778 - Added support for Sequences (MSequence). Sequences are blocks of run
2779 files containing the same calibration and belonging to the same
2780 source
2781
2782 - Added a new task (MTaskEnv) which can be used in setup files to switch
2783 between different tasks (for example to choose a signal extractor)
2784
2785 - Implemented automatic file splitting in MWriteRootFile
2786
2787 - After image cleaning an island index is assigned to all used pixels.
2788 The index corresponds to the order of the islands in size.
2789
2790 - added a cleaning which takes signal height _and_ arrival time into
2791 account: probability cleaning (for more details see MImgCleanStd)
2792
2793 - added a cleaning which takes takes the absolute number of photons
2794 times the area ratio as cleaning level
2795 (for more details see MImgCleanStd)
2796
2797 - Changed calculation of image parameters such, that it can be done
2798 for all used pixels or the pixels with a defined island index only
2799
2800 - implemented new image parameters displaying the number of islands,
2801 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2802
2803 - event display in executable changed to support also calibrated files
2804 (done with MJCalibrateSignal)
2805
2806 - added program doing the calibration and the signal extraction
2807 and signal calibration: callisto Most part of the setup is done
2808 by a resource file: callisto.rc
2809
2810 - implemented support for pixels with negative IDs (Raw file format
2811 version 4)
2812
2813 - implemented an new option in merpp (--auto-time) to get the time
2814 range for cc and/or caco data from the run header of the raw data
2815
2816 - New star-program (star and MJStar). Taking calibrated data from
2817 callisto/MJCalibrateSignal as input. The setup is done through
2818 a resource file: star.rc
2819
2820 - Added possibility to setup the eventloop in the mars-executable
2821 Camera Display by a resource file: mars.rc
2822
2823 - The the mars-executable Camera Display can now also read
2824 calibrated data files written by callisto/MJCalibrateSignal
2825
2826 - Added a new class which can calculate the source position in
2827 the camera from a pointing model known to be correct and
2828 the pointing model used for observations (MSrcPosFromModel)
2829
2830 - added a new version of the class calculating the effective on-time
2831 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2832 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2833 MHTimeDiffTheta.
2834
2835 - added the possibility to count how often a signal is above (or
2836 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2837 can replace MHTriggerLvl0)
2838
2839 - added ore convinient ways to set the axis-titles of your histograms
2840 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2841 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2842
2843
2844
2845 *** Version 0.8.5 (2004/08/06)
2846
2847 - new Signal Extractors: MExtractFixedWindowSpline
2848 and MExtractAmplitudeSpline
2849
2850 - implementes interleave in merpp to be able to merpp parts of a file
2851
2852 - implemented force-functionality to merpp
2853
2854 - star display to display star catalogs (MAstroCatalog)
2855
2856 - star display to 'mirror' stars to the camera (MAstroCamera)
2857
2858 - implemented a new cleaning option which allows cleaning scaled with
2859 the real ratio of the rms depending on the pixel size, not only the
2860 square root of the pixelsize (MImgCleanStd, MCameraData)
2861
2862 - removed obsolete MBlind* classes
2863
2864 - Signal extractor taking the AB flag into account implemented (this makes
2865 an odd number of slices for signal extraction possible
2866 (MExtractSignalABcorr)
2867
2868 - implemented a class extracting the pedestal from the raw-data (events)
2869 itself using empty lo-gain (MpedCalcFromLoGain)
2870
2871 - Added mean values to MPedPhotCam
2872
2873 - Added Makefile for Darwin (this OS is NOT officially supported!)
2874
2875
2876
2877 *** Version 0.8.4 (2004/04/19)
2878
2879 - new fast arrival time extractor using cubic splines:
2880 MExtractTimeFastSpline
2881
2882 - implementes multi-argument support in MDataChain
2883 ("pow(a, b)")
2884
2885 - implemented double reference support in MDataChain
2886 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2887
2888 - added support in MF for expressiond like
2889 "MHillas.fWidth<2*<MHillas.fLength"
2890
2891 - MDataChain is now able to support variables like [0], [1], ...
2892 which can be used in fit functions as parameters. The interface
2893 is implemented through the new virtual function
2894 MParContainer::SetVariables
2895
2896 - added new class MArrivalTimeCam/MArrivalTimePix:
2897 Storage containers to hold the ArrivalTime of the camera/pixel
2898
2899 - added new classes for the calibration of relative arrival times:
2900 MCalibrationRelTimePix and MCalibrationRelTimeCam
2901
2902 - added new classes to extract the signal of the blind pixel and the
2903 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2904
2905 - added new classes for the bad-pixels treatment (MBadPixels*)
2906 which are more powerfull than the old ones (MBlindPixel*)
2907 and will replace them.
2908
2909 - added filter against cosmics: MFCosmics
2910
2911 - added new class MArrivalTimeCalc2:
2912 Calculates the arrival time as the signal weighted mean of the time
2913 slices in the maximum window
2914
2915 - added a new macro call pointspreadfucntion.C that fits with a 2D
2916 gaussian the DC spot for an star. It gives you the RMS of
2917 the PSF and the center of the star, very useful for misspointing
2918 studies.
2919
2920 - added support for multi-telescope camera files. Added classes
2921 MStereoCalc and MStereoPar, classes to calculate and store shower
2922 parameters calculated from the data of two telescopes, for the MC
2923 studies regarding the MAGIC clone.
2924
2925 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2926 MC data calibrated in photons instead of ADC counts.
2927
2928 - added three macros to show the calibration and analysis chain of
2929 MC data. The macro starmc.C does both calibration and analysis, producing
2930 an output containing Hillas parameters for each event. The macro
2931 mccalibrate.C does just the calibration and writes out a file containing
2932 pixel information in photons instead of FADC data. The macro starmc2.C
2933 reads in such a file and produces an output with Hillas parameters.
2934
2935 - added MPedPhotCalc to compute pedestals in units of photons, see
2936 macro pedphotcalc.C
2937
2938 - added all class to perform the calibration, see macro calibration.C
2939
2940 - added class MFFT to perform Fast Fourier Transforms
2941
2942 - added class MSimulatedAnnealing to perform simulated annealing
2943 minimizations
2944
2945 - added new macro bootcampstandardanalysis.C which holds the skeleton
2946 of the analysis chain discussed in the december bootcamp.
2947
2948 - added support for DAQ raw data file format V2
2949
2950 - implemented an arbitrary time stamp for the events from raw-data
2951 files with file version<3. It is calculated from the run number,
2952 the date of start and the FADC clock tick from the first module
2953
2954 - implemented the correct decoding of the event time-stamp
2955 coming from the DAQ for raw-data files with file-version>2
2956
2957 - added a new classes storing the pedestals in units of photons:
2958 MPedPhotPix, MPedPhotCam
2959
2960 - added support for DC current files from the camera control
2961
2962 - added support for start- and stop-time when merpping report files
2963
2964 - added MReportCC storing the weather data from the CC-REPORT
2965
2966 - added class to fill trainings and test matrices (MTFillMatrix)
2967
2968 - added a filter performing a software trigger (MFSoftwareTrigger)
2969
2970 - Added classes to perform parts of the standard analysis (Jobs):
2971 + MJPedestals
2972 + MJCalibration
2973 + MJExtractSignal
2974 Note: All of them are preliminary!
2975
2976 - Added Iterator to iterate over files giving only the run-number
2977
2978 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2979 the evolution of a sector vs time
2980
2981
2982
2983 *** Version 0.8.3 (2003/12/05)
2984
2985 - adapted Random Forest classes to allow the use with MC
2986 multi-telescope files which can be produced with the coming
2987 camera version 0.7.
2988
2989 - added classes to read and interprete central control report files
2990 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2991
2992 - enhanced merpp (the executable) to support .raw and .rep files.
2993
2994 - added classes for light calibration (MCalibration* and
2995 MHCalibration*) by Markus Gaug. Further work has to be and will
2996 be done soon.
2997
2998 - Added a preliminary 'synchronizer' (MReadReports) which will
2999 replace MReadMarsFile as soon as it is finished.
3000
3001 - Added a tutorial macro demonstrating how report files are merpped
3002 and how they can be read from the root file in the correct order
3003 of time (readrep.C)
3004
3005 - Added a generalized histogram (similar to MH3) called MVsTime
3006 which allows to plot variables (or rules - MDataChain - of
3007 variables) vs time. For an example have a look at tempvstime.C.
3008
3009 - Changed the name of the event trees:
3010 + Events --> Events
3011 + PedEvents --> Pedestals
3012 + CalEvents --> Calibration
3013
3014 - changed name of MTime in the event trees from MRawEvtTime to MTime
3015
3016 - added displaying the sector indices to the mars event display
3017
3018 - Magic Online Analysis (MOnA) implemented in a first version
3019 (see mona.cc, MOnlineDump and MOnlineDisplay)
3020
3021 - added classes to calculate event rate
3022 (preliminary: MEventRateCalc, MEventRate)
3023
3024 - added new executable 'readdaq' to read *.raw files from the DAQ directly
3025
3026 - added classes dealing with the telescope pointing position (MPointing*)
3027
3028 - implemented the 'final' Mars time stamp based on some experiences with
3029 the new 'Synchonizer'
3030
3031
3032
3033 *** Version 0.8.2 (2003/11/10)
3034
3035 - accelerated standard analysis by a factor of 6-8 ...
3036 + doing precalculations in MGeomCam for the pixel area ratio
3037 + creating a look up table for the single pixels in MCerPhotEvt
3038
3039 - added task to calculates weights in case you want to 'change'
3040 the energy spectrum of a monte carlo file
3041 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
3042
3043 - added a new executable star which implements the
3044 star.C macro as precompiled executable. Currently a flexible
3045 setup is not possible, but a 'input card' setup will follow.
3046
3047 - Starting to implement Multi-Telescope-Support based on the
3048 upcomming camera version 0.7. The base for a general support
3049 is implemented and the star-functionality is proven to work.
3050
3051 - Replaced Event-Display in and Camera-Display in the Mars GUI
3052 executable by a more convinient display base on MStatusDisplay.
3053
3054 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
3055
3056
3057
3058 *** Version 0.8.1 (2003/10/20)
3059
3060 - added signal subtraction for pure on data by means of fitting
3061 the background in the off region or by performing a combined
3062 signal/background fit. Provides necessary histograms for
3063 obtaining energy spectra and a light curve.
3064
3065 - added classes to perform and study the selection of the
3066 2nd Level Trigger on MC data (example in triglvl2.C macro)
3067
3068 - added pedestal calculation
3069
3070 - implemented "democratic cleaning" (tail cut value proportional
3071 to pixel area) according to Wolfgang's suggestion.
3072
3073 - added Sigmabar treatment (calculation and basic histogramming)
3074
3075 - added basic routines to apply padding
3076
3077 - added first implementation of MARS-based source visibility plotter
3078 (needs to be linked against slalib, preliminary version)
3079
3080 - enhanced functionality of data chains: random numbers, conversion
3081 functions and access to MHMatrix objects
3082
3083 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
3084 numbers under certain circumstances (runs with 0 events included)
3085
3086 - fixed a bug in the general filter MF (didn't work on some systems
3087 at all)
3088
3089 - fixed a bug in chaining files, which caused the analysis to crash or
3090 ignore files
3091
3092 - implemented more geometry classes describing the parameters used
3093 to simulate the PMT camera
3094
3095 - added new Monte Carlo classes containing the setup of the different
3096 programs in the MC chain.
3097
3098 - added a (preliminary) general task to evaluate chi-square of a given
3099 parameter in an eventloop.
3100
3101 - first implementation of a container describing the observatory
3102 location (Long, Lat, etc)
3103
3104 - added Random Forest - method for g/h-separation
3105
3106 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3107 (this means, that it is compiling, but not yet fully tested)
3108
3109 - added a new status display which can show the present status
3110 of histograms while an eventloop is running (MStatusDisplay,
3111 an example can be found at status.C)
3112
3113 - reorganized directories:
3114 classes describing the image --> mimage
3115 classes containing Monte Carlo Histograms --> mhistmc
3116 classes for Random Forest method --> mranforest
3117
3118 - added (event-)weights to fill histograms
3119
3120 - colors in logging output to screen
3121
3122 - changes to the Image Parameter declaration:
3123 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3124 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3125 + MHillasExt now derives from MParContainer instead of MHillas
3126 --> Files written with the old definition are more or less unreadable
3127
3128 - reading of reflector files
3129
3130 - display data from reflector files in the camera
3131
3132 - implemented currents (and display them in the camera)
3133
3134 - logarithmic scale in camera
3135
3136 - added class to iterate through directory contents (MDirIter)
3137
3138
3139
3140 *** Version 0.8 (2002/11/18)
3141
3142 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3143
3144 - corrected 48(!) wrong entries in the Next Neighbor table of the
3145 Magic Camera (all in the inner part of the outer ring, mostly
3146 missing a single NN)
3147
3148 - Fixed a bug in the table describing the Next Neighbours of the
3149 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3150 have any neighbour)
3151
3152 - changed trigrate.C: now it calculates the pure NSB triggers from
3153 a camera file (generated with no showers), so there is no need
3154 to introduce them by hand in the BgR array (for more details
3155 please ask Abelardo)
3156
3157 - added MHHadronness (and MHadronness) as a general facility to evaluate
3158 the quality of a gamma-hadron seperation method
3159
3160 - changed MWriteAsciiFile to accept rules (MDataChain)
3161
3162 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3163 must be replaced by calles to MWriteAsciiFile::AddColumn and
3164 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3165 changed.
3166
3167 - Implemented generalized event-matrices (one row per event)
3168 (MHMatrix)
3169
3170 - implemented the one dimensional composite probabilities
3171 (MHCompProb, MCompProbCalc, comprob.C)
3172
3173 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3174 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3175
3176 - Added a camera display displaying the pixel numbers to the
3177 event display gui.
3178
3179 - Added Monte Carlo Informations to event display gui
3180
3181 - Changed the camera display to display the pixel numbering
3182
3183 - Added three buttons to the camera display to change the palette
3184
3185 - Added the number of used and core pixels after image cleaning
3186 to MHillas
3187
3188 - Changed the algorithm used in MHillas according to TDAS 02-03
3189
3190 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3191
3192 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3193
3194 - Added fCosDeltaAlpha to MHillasSrc
3195
3196 - The numbers of photons used to calculate fConc and fConc1 in
3197 MHillasExt are now scaled with the pixel size, so that one get
3198 a four times smaller value for the bigger pixels in the outer ring.
3199
3200 - added new task to smooth the camera contents (MCameraSmooth)
3201
3202 - added possibility to use interpolated pixel values for blind pixels
3203 instead of removing it completely from the analysis
3204
3205 - Implemented the possibility to save the whole eventloop with
3206 its setup to a file. This information can be read and from
3207 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3208 and MEvtLoop::MakeMacro. If you find something not working, please
3209 report - this stuff is still in a beta phase.
3210
3211 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3212 file having crab starfield, but also for all following files - fixed
3213
3214 - MTaskList::PrintStatistics can now be instructud to print also the
3215 title, too: use PrintStatistics(0, kTRUE)
3216
3217 - Changed the image cleaning so that pixels with to many 'used'
3218 neighbors are left used (to get rid of 'holes' in events)
3219
3220 - Introduced more output to the camera displays
3221
3222 - Added an array of histograms (eg one hist per run), MHArray
3223
3224 - Added a _preliminary_ version of the reader for CT1 PreProc files
3225 (MCT1ReadPreProc)
3226
3227 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3228 (thanks to Raquel)
3229
3230 - added the first energy estimator (MEnergyEstParam, estimate.C,
3231 estfit.C) using a parametrization
3232
3233 - Added some new Monte Carlo paremeter containers used to store
3234 setup information from the MC chain (MMcConfigRunHeader,
3235 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3236
3237
3238
3239 *** Version 0.7 (2002/04/30)
3240
3241 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3242 the pedestal mean value was saved incorrectly. For files from
3243 this versions we substract 0.5 from the pedestal mean.
3244 WARNING: This may effect your results, so don't wonder...
3245
3246 - First implementation of an algorithm using only triggered events
3247 for the collection area calculation
3248
3249 - Ascii Output can now also be used for parameter containers which
3250 doesn't overload MParCointainer::AsciiWrite
3251
3252 - The Ascii Output is now also capable of writing single data members
3253 of one container
3254
3255 - You are now able to change the order of the values written to the
3256 ascii file
3257
3258 - You can now specify a conversion factor for each data member written
3259 to an ascii file. This may be usefull to change the units of the
3260 data member (eg. degrees instead of millimeters in case of the
3261 hillas parameters)
3262
3263 - Replaced old MHillas by a new structure which allows you to extend
3264 the parameters stored in MHillas very easily:
3265 see MHillas and MHillasExt
3266
3267 - Added classes to handle source dependancy of image parameters:
3268 see MHillasSrc
3269
3270 - Added container (MBinning) to have a standard input for the binning
3271 in different histograms (eg. the Energy bins should be the same in
3272 all histograms)
3273
3274 - Changed Hillas histograms from mm to deg
3275
3276 - Added the flexible binning to the hillas histograms
3277
3278 - Added a filter for the alpha parameter (MFAlpha)
3279
3280 - It is now possible to write single data members of a class object to
3281 an output stream instead of the whole container only
3282
3283 - Added a generalized filter for a data member:
3284 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3285
3286 - Added a generalized Filter parser for more difficult filter rules
3287 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3288
3289 - Added new Monte Carlo histograms:
3290 MHMcEnergyImpact and MHMcEfficiency
3291
3292 - Added many new histograms needed for the flux calculation.
3293
3294 - Added a generalized histograms which can fill and show up to three
3295 data members in either a one-, two- or three-dimensional histogram, eg:
3296 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3297
3298 - Added:
3299 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3300 * calculation of <Theta> as a function of time (MHThetabarTime)
3301 they are needed in the flux calculation in
3302 order to select for a given bin in Theta (or time) the appropriate
3303 effective collection area, which is assumed to be given as a function
3304 of Theta and the true energy
3305
3306 - Added calculation of the migration matrix in the energy
3307 (MHMcEnergyMigration):
3308 the migration matrix describes the migration from the true (E_true)
3309 to the estimated energy (E_est); it is needed to determine the
3310 distribution of E_true from the measured distribution of E_est
3311 by unfolding
3312
3313 - changed the color palette in the camera display to DeapSea.
3314
3315
3316
3317 *** Version 0.6 (2002/01/15)
3318
3319 - Introduce the option of disable pixels (MBlindPixels and
3320 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3321 able to deal with Star Field NSB.
3322
3323 - Fixed a bug in the pedestals substraction
3324
3325 - Introduced verbosity levels
3326
3327 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3328
3329 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3330 work correctly (thanks to Abelardo)
3331
3332 - Introduced correct treatment of the diffuse Night Sky Background
3333 and NSB (MMcPedestalNSB)
3334
3335 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3336
3337 - Introduced MMcRunHeaders which contains monte carlo run informations
3338
3339 - Added a 'Print'-Task (MPrint) which calls the Print function
3340 of a parameter container for each event
3341
3342 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3343
3344 - changes to be more efficient with root 3.02/06
3345
3346 - root 3.02/06 fixes:
3347 + the memory leak when reading MRawEvtData
3348 + loosing more time than necessary to update the progress bar
3349
3350 - MWriteAsciiFile is now capable of writing more than one container
3351 in a line. For example: To be able to write Monte Carlo and
3352 Hillas values (energy and alpha) in one line.
3353
3354
3355
3356 *** Version 0.5 (2001/11/06)
3357
3358 - Added new GUI functionality (Analysis)
3359
3360 - Added a camera display to be able to display events in the camera
3361 together with the calculated hillas ellipse
3362
3363 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3364 object at any state of the analysis, so that the output are several
3365 states
3366
3367 - Fixed a bug in the collection area error calculation
3368 (Thanks to Ciro and Abelardo)
3369
3370 - Fixed a bug which causes merpp to crash in some environments
3371
3372 - Implemented auto enabling scheme for Branches to speed up reading
3373 a lot (see MReadTree and MTask)
3374
3375 - Fixed a bug in the Histogram classes which caused histograms to
3376 be written to a file by MWriteRootFile without request
3377
3378 - changed the object I/O from the old stylish root I/O to the new
3379 'auto evolution scheme' This was done only for classes which are not
3380 yet used in Monte Carlo files, so that these files are still readable.
3381
3382 - Added support for a progress bar in MEvtLoop and MReadTree
3383 (see the Analysis Window in Mars for an example)
3384
3385 - Fixed a bug in the package creation which disturbed the conversion
3386 between a mars version unpacked from a tar file and the repository.
3387
3388 - Changed the code to writer merpped (converted into root format)
3389 raw files, to get faster (around 10%)
3390
3391
3392
3393 *** Version 0.4 (2001/09/20)
3394
3395 - This release is made to compile on a root version >= 3.00
3396
3397 - Fixed a bug which causes MReadTree to read the first file only
3398
3399 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3400
3401 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3402
3403 - Added a task to write several container to a root file (MWriteRootFile)
3404
3405 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3406
3407 - Added calculation of the collection area (MMcCollectionAreaCalc)
3408
3409 - fixed some bugs in the Hillas calculation
3410
3411 - added filters to be able to control the task execution dependent on
3412 a parameter (for example: the number of level 1 triggers in a MC-file)
3413
3414
3415
3416 *** Version 0.3 (2001/04/23)
3417
3418 - Many demo macros added
3419
3420 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3421
3422 - Hillas Calculation added
3423
3424 - Standard image cleaning available
3425
3426 - MReadTree is now able to handle more than one file
3427 (Remark: of the same structure)
3428
3429 - Now we are able to display events in a first version of the
3430 Camera event display. To do this we must run the macro
3431 "macros/readCT1.C" to read data from CT1.
3432
3433
3434
3435 *** Version 0.2 (2001/01/24)
3436
3437 - First Implementation of a Gui to read the raw data. Start the
3438 gui with the command mars.
3439
3440
3441
3442 *** Version 0.1 (2000/12/20)
3443
3444 - First official release 0.1
3445
3446 - Changes:
3447
3448 + changed calling style of MRawPixelIterator from do...while to
3449 while-loop
Note: See TracBrowser for help on using the repository browser.