source: trunk/Mars/NEWS@ 9845

Last change on this file since 9845 was 9845, checked in by tbretz, 15 years ago
Implemented new parameters to describe the time spread in MHillasExt.
File size: 139.3 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * On some systems (version of make?) the __LINUX__ definition was not set
8 when compiling. This lead to MTime(-1) not working properly. Fixed.
9
10 * The status display is now able to write a plain root file which means
11 that the MStatusArray container is omitted and the TCanvas are written
12 to the file directly. This allows to write files which are accessible
13 from a plain root (without MARS) if no MARS objects are contained
14 in the TCanvas'. In turn the reading of files which contains
15 objects and TCanvas' but no MStatusArray object has been improved.
16
17 * MMcEvt.fPhi and MMcEvt.fTheta have been moved to its base class
18 MMcEvtBasic. Consequently, the direction of the primary shower
19 is not lost in the OriginalMC tree anymore
20
21 ;ceres:
22
23 * Allow for individual mirrors with parabolic shape (for details see
24 MReflector::ReadFile)
25
26 * As an additional output artificial star-files are written. They
27 contain star output compatible output based on the signal as
28 in the artificial callisto output files.
29
30 * The trigger channel which issued the trigger is now stored in
31 MRawEvtHeader::fNumTriggerLvl1
32
33 * The number of photons in the calibration signal is now distributed
34 by a possonian instead of a Gauss.
35
36 * implemented new file-naming scheme (corsika run-number is new
37 tranfered to the ceres output as file-number). Therefore a new option
38 has been implemented to set an artificial run-number:
39 ---run-number=12345
40
41 * The baseline, the baseline noise and the gain (multiplicator to the
42 pulse) are now accessible from the outside. The new values are:
43 MSimCamera.DefaultOffset
44 MSimCamera.DefaultNoise
45 MSimCamera.DefaultGain
46
47 ;star:
48
49 * The time constraint in the image cleaning is now scaled with the
50 pixel distance. Consequently, the value given is not absolute in
51 ns anymore, but in ns/deg. This means that the values for MAGIC
52 have to be scaled by a factor of 10.
53
54 * Star now calculates new timing parameters, namely:
55
56 ** MHillasExt.fTimeSpread:
57 This is the time spread (rms) around the mean of the arrival times.
58 It is calulated as
59 <math>\sqrt{\sum{t_i}/n}</math>
60 ** MHillasExt.fTimeSpreadWeighted:
61 This is the weighted time spread (rms) around the weighted mean of the arrival times.
62 It is calulated as
63 <math>\frac{1}{\sum{n_i}}\sqrt{\sum{n_i^2(t_i-<wt>)^2}}}</math>
64 or
65 <math>\frac{1}{\sum{n_i}}\sqrt{\sum{n_i^2t_i^2}+<wt>^2\sum{n_i^2}-2<wt>\sum{t_in_i^2}}</math>
66
67 ;trainenergy.C:
68
69 * The rsolution is not displayed anymore as resolution squared
70
71
72
73== Version 2.4 (2009/12/23) ==
74
75 ;general:
76
77 * Added a new palette "temp" to MH::SetPalette which should resample
78 a temperature
79
80 * Added consistency check for two consecutive runs
81
82 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
83 has been disconnected and the L1 (L1TPU) has directly been connected
84 to another bit in the trigger pattern. This has been fixed by an
85 update of the decoding. Both bits are now or'ed together.
86
87 * Added a new camera layout MGeomCamFact which is the "four rectangular
88 pixels ordered in a hexagonal geometry" layout
89
90 * All programs now store the command line as TNamed "CommandLine"
91
92 * the environment variable OSTYPE should now be obsolete. Instead
93 the output of "uname -s" converted to lower cases is used
94
95 * The Makefiles should now detect the OSTYPE automatically using
96 uname. This should make the setting of OSTYPE obsolete
97
98 ;showplot:
99
100 * If a file without a MStatusArray is opened all object (not just
101 canvases) found in the file are drawn. Note that this may result
102 in empty tabs.
103
104 ;ceres:
105
106 * The night sky noise is now scaled with the sensitive area and
107 is given in units per square centimeter
108
109 * The night-sky noise now also takes the cones transmission
110 into account
111
112 * The night sky noise can now be calculated from a night-sky
113 spctrum
114
115 * A transmission curve for the cones can now be given
116
117 * Added the possibility to add a cut after the image parameter
118 calculation (''Cut'')
119
120 * updated the PDE of the GAPDs with a more reliable curve from
121 the meeting page (linear extrapolate below 350nm)
122
123 * The impact distribution in the event distrbutions is now
124 perpendicular to Alt/Az and the histogram is displayed in 1D
125
126 * The GAPD PDE has been updated
127
128 * PDEs and mirror reflectivities have been linearily extrapolated
129 to match the wavelegth range between 290nm and 900nm
130
131 * There is no default pulse shape anymoe it must be given in
132 the resource file
133
134 * Fixed a bug which caused the aerosol coefficient to be incorrectly
135 initialized. The effect might be random but seems to be small.
136
137 * Now accepts sequence files as input
138
139 * creation of pedestal and calibration files is now steered by
140 --mode (see ceres help)
141
142 * Instead of initializing the whole G-APD chip (all cells) before
143 each event (which is rather time consuming) a time evolution before
144 each event is now simulated which is enough to recovere every cell
145 to 99.999% of its response taking the background rate into account.
146 This is in total about a factor of ten faster and should not be
147 less accurate because under normal conditions the recovering cells
148 and the newly hitten cells will hardly be identical (due to
149 statistical reasons)
150
151 * improved the trigger algorithm which is now faster and allows easily
152 for multiplicity triggers
153
154 * The PDC flag in the file name is now correctly written
155
156 * A "PreCut" has been added which can be used after reading the events
157 to select them even before any calculation is done.
158
159 ;merpp:
160
161 * The new drive reports which contain also the status of the starguider
162 are now implemented, but the starting date (17/05/09) is preliminary.
163
164 ;callisto:
165
166 * Fixed a bug which prevented MAGIC Monte Carlo file from being
167 calibrated (ceres files worked)
168
169 * updated (Muon) calibration constants of period 62, 63, 72-75
170
171 ;star:
172
173 * allow to run thru even if discriminator threshold are missing
174 (they are not used for analysis so far anyway)
175
176 ;ganymed:
177
178 * added new starguider calibration for sequences since 1000534
179
180 ;database:
181
182 * added possiblity to query/plot data from certain source (with
183 regular expressions) in plotdb.php
184
185 * new feature in showplots*.php: on mouse-over additional information
186 on the sequence is displayed
187
188 * tables on database website have also 'Last' link now
189
190 * new version of builddatasets.php with more comfortable sequence
191 selection
192
193 * new features in builddatasets.php:
194 - user management
195 - 'Get Data Set File' button
196 - 'Display Selected Sequences' button
197 - 'Display Not Selected Sequences' button
198 - 'Select all' buttons
199
200 * builddatasets.php: added possibility to update data sets in the
201 database
202
203 * added limit for cloudiness for sequences in the tab 'Limits'
204
205 ;automation:
206
207 * jobmanager can be used more flexible now: via environnent variable
208 $AUTOMATIONSETUP more than one jobmanager per user can be started
209 using the same MARS version
210 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
211 and provide a file Mars/datacenter/scripts/setup.mysetup
212
213
214
215== Version 2.3 (2009/03/07) ==
216
217 ;SUGGESTION
218
219 * There is no need to re-run any data because no change took place which
220 could have an effect on the output. However, if you want a
221 meaningful SrcPos plot for your MCs in sponde you must re-process
222 star for your MCs first.
223
224 ;REMARK
225
226 * File produced with this release containing a camera geometry (which
227 are basically all files were produced as default) will not be readable
228 by older releases.
229
230 ;general
231
232 * fixed a few small bugs which could cause the display to crash in ganymed
233 and sponde
234
235 * in sequence file the date can now be omittet. In this case the
236 leading date with the underscore is missing in the expected filename
237
238 * the geometry class now also supports other geometries than just hexagons
239
240 ;automation
241
242 * added magnetic field Azimuth direction (ARRANG), currently
243 at ~ -7deg at La Palma
244
245 ;database
246
247 * plotdb.php: added default (sequences) for startup, added possibility
248 to set size of plot
249
250 * added a new table ''RunDataCheck'' which containes the rates after
251 image cleaning for every run which succeeded star. It can be
252 plotted using ''plotrundb.C''
253
254 ;merpp
255
256 * added support for Arehucas Version >= 200812140
257
258 * added support for Arehucas Version >= 200809030
259
260 ;mars
261
262 * The display now also displays the trigger pattern
263
264 * The display can now display ceres reflector (_R_) files
265
266 ;ceres
267
268 * added a uniformly distributed one-bin time jitter for the start of the
269 digitization. Otherwise the first photon would be digitized always with
270 the same alignment to the bins
271
272 * Added a plot showing the production height of the photons
273
274 * Moved the particle id from the event header to the run header
275
276 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
277
278 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
279
280 * Added many new options to control the tasks. For deatils see ''ceres.rc''
281
282 * Removed obsolete plots in pedestal and calibration mode
283
284 * Removed the non-NightSky photons from the plots where they are just
285 disturbing
286
287 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
288
289 * The daq event number now represents the readout number
290
291 * The camera ''electronics'' can now be ''switched off''
292
293 * A new tab ''Info'' now display basic things like the reflector
294 layout
295
296 * Improved reading speed for corsika files
297
298 * Improved memory handling (if a large ampount of memory was needed
299 for a single event all further events were stored in the same
300 memory and it was never freed, so the program took this memory
301 until the end)
302
303 * Converted the code from MMCS' reflector program to MSimAtmosphere
304 (instead of the tables build in for MAGIC Winter and Summer
305 atmosphere we use the values written by Corsika fitted to the
306 tabulated atmosphere given as input)
307
308 * For caluclating the displayed image parameters in ceres a basic
309 image cleaning removing isolated pixels is now done.
310
311 * The magnetic field direction (ARRANG) is now taken into account
312
313 * Added plot for the energy threshold after trigger ''Threshold''
314
315 * Added plot for the effective collection area after trigger ''TrigArea''
316
317 ;star
318
319 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
320
321 * The definition of fConcCore has slightly changed. The numbers
322 might decrease a little bit (the effect should be rather small)
323
324 ;ganymed
325
326 * added pointing model 328198
327
328 ;sponde
329
330 * The SrcPos plot for your MCs was so far meaningless because it just
331 displayes the MSrcPosCam data from the input star-files. Unfortunately,
332 this containes was never written to the star-files yet.
333
334 * A new Tab 'OnTime' is available which is an effective on-time
335 fit as in star but for all data. This is mainly for manual cross-check
336 of the effective on-time
337
338 * In some circumstances it might be necessary to re-calculate the
339 eff. on-time from the fit in the new tab, e.g. when a zenith distance
340 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
341
342 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
343 it to its own output file (for convinience)
344
345
346
347== Version 2.2 (2009/01/30) ==
348
349 ;SUGGESTION
350
351 * This release doesn't contain a major change which is expected to
352 change your results. Nevertheless there are small changes to
353 the calibration which can effect at least the first few hundred
354 events in any (mainly MUX and even more SUM) sequence a little bit.
355 So it is recommended although not necessary to reset your sequences
356 in the database before further processing.
357
358 ;NEW
359
360 * A first implementation of a Monte Carlo simulation program
361 (ceres - Camera Electronics and REflector Simulation) has been
362 implemented. It can simulate a full telescope already including
363 a complete reflector simulation and a flexible trigger and readout
364 simulation. Currently, no perfect setup is implemented and
365 especially the output of the program (data structure) should
366 be considered alpha state. Also the user interface is not yet
367 ready.
368
369 ;general
370
371 * All command line options after -- are now interpreted as
372 arguments (usually everything which doesn't start with a minus)
373 rather than options (usually everything which starts with a
374 minus). This allows to use file names starting with a -
375
376 * In all resource files you can now initialize the random number
377 generator. For details see: MJob::InitRandomNumberGenerator
378
379 * added a new program called ''readcorsika''. It's purpose is (in analogy
380 to readraw and readdaq) to read a Corsika output file (for now
381 only cherenkov output is supported) and print its contents in a
382 human readable form. It can also write the contents of this file
383 into a root-file.
384
385 * The calculation of the maximum distance to the origin in a MGeomCam
386 has been improved (edges might be further away than the sides).
387 This is just a tiny change but it might change the appearance of
388 the radial profiles a little bit.
389
390 * The default binning of the center-of-gravity plot has slightly been
391 increased
392
393 ;Database
394
395 * Added informations about the DC currents (fMinCurrents, fMedCurrents
396 and fMaxCurrents). The values are retrieved from the plots showing
397 the average DC currents of all pixels versus time.
398
399 * Websites with tables have now the opportunity to remove lines
400 ('-' button at beginning of each line) and get all lines back
401 ('+' at top of the column)
402
403 * Websites: added option to query only sequences containing sumtrigger
404 events
405
406 * Websites: added option to group by date (year, month, night) for runs
407 and sequences and enabled that combining of different group-bys,
408 e.g. status, date and source is possible
409
410 ;automatic analyis
411
412 * Rewritten producing plots in the web.
413 New plots, namely the output of plotoptical.C (extinction curve from
414 KVA), plotstat.C (status of the automatic analysis (percentage of
415 processed, analysed data etc.)) and plotusage.C (statistics of the
416 condor usage in the data center) has been are available now next to the
417 plots of plotdb.C
418 Mean values from the plots (output of the macro) are provided in a
419 txt file now.
420 The creation of the plots for callisto, star and ganymed in the web is
421 now steered via database. Consequently the plots are faster and
422 reliable up-to-date.
423 For all plots, a new layout is available facilitating the browsing
424 through the plots and providing additional information on the
425 displayed values. (tabs.php) These plots are linked from the DB
426 websites and the wiki.
427
428 ;statusdisplay
429
430 * The ''Loop'' entry in the menu bar now contains an option to pause
431 the loop and to process single events.
432
433 ;merpp
434
435 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
436 instead of RunHeaders)
437
438 * Now allows to merpp files newer than 2008/09/03.
439
440 * Added fixes for wrong (wrong or double) run- and file-numbers
441 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
442
443 ;callisto
444
445 * Extracting the pulse position for the pulse position check events
446 with sum trigger were denied. This decreased the statistics
447 extremely and therefor the resulting puse position was calculated
448 quite weak. Now sum events pass the calculation if and only if they
449 have also a level 1 trigger.
450
451 * the extraction of pedestal events and pulse position from the
452 first data events is now more automatic and makes sure that
453 a more precise number of events is extracted independent of
454 the ratio with which pedestal events or events with signals
455 are contained in the data.
456
457 * Updated Muon calibration constants for all MUX data (teh changes were
458 all smaller than 5%)
459
460 ;star
461
462 * For the calculation of the effective on time all sum-triggered events
463 were skipped. Now all Level1-triggeres events will pass. This might
464 result in a slight inaccuracy of the effective on time.
465
466 ;ganymed
467
468 * If the source position is more than 1deg away from the camera
469 center an error is raised now.
470
471 * Hopefully fixed the bug ''ganymed crashes when resized''
472
473 ;sponde
474
475 * Fixed a problem which causes the fitted spectral slope to be displayed
476 incorrectly. If you use MJSpectrum::FormFlux in your macros make
477 sure that the parameter 0 of your fit is negative.
478
479 * Added a histogram showing the read source position of your MCs
480
481
482
483== Version 2.1.1 (2008/08/04) ==
484
485 ;Database
486
487 * Added the median number of photo electrons from the calibration
488 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
489 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
490
491 * Added fTotOnTime, which is the on-time as given by the run-headers
492 (in contradiction to fAbsOnTime which comes from CC)
493
494 * Added new primaries for the new data structure (Magic II): for the
495 tables dealing with sequences (SequenceBuild Status, Sequences,
496 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
497 this is the telescope number (fTelescopeNumber) for the tables dealing
498 with runs (RunData and RunProcessStatus) this is in addition the file
499 number (fFileNumber)
500
501 * Added column fPriority to the status tables to be able to steer the order
502 in which the data is processed. As default the run, sequence and dataset
503 number are used.
504
505 ;automatic analyis
506
507 * Adapted scripts to the new data structure: They can handle now different
508 telescopes (getting the information as usual from the database).
509 The paths for Magic 2 are not yet implemented.
510
511 ;general
512
513 * should work now with root 5.20/00 (please note that root 5.20/00
514 we encounter crahses in the status display which are ot yet
515 understood)
516
517 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
518 instead of the base name of the file. This makes them easier to
519 access from the code
520
521 * Default Monte Carlo names in MSequence do not require the _E at
522 the end anymore
523
524 * where abrrevating a sequence file with a sequence number is possible
525 also "telescope:sequence" is now accepted, e.g.:
526 star 2:2000123 --out=output
527 see the programs' help for more details.
528
529 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
530 from the database. See the constructors for more details.
531
532 * MReadTree now supports friends
533
534 * MReadTree can now read also files not written by MARS and store
535 the data encapsulated in emulated MParContainers
536
537 * added a new starguider calibration valid since 15.1.08
538
539 ;showplot
540
541 * showplot can now read more than one file at once. This is especially
542 inetersting if reading files containing pure canvases
543
544 ;merpp
545
546 * we merpp the dc currents now also from the camera reports (they have
547 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
548
549 * In the automatic analysis we omit merpping of the currents from the
550 caco files and use the lower rate camera reports from the cc files
551 instead
552
553 * merpp has been redisigned to allow merpping of the cc-reports
554 of a whole sequence. This allows to design a very simple analysis:
555 mkdir output
556 ./callisto 100776 --out=output
557 ./merpp 100776 output
558 ./star 100776 --ind=output --out=output
559 Instead of the sequence number also sequence files are accepted.
560
561 * Implemented a fix for run-numbers between 1001348 and 1001396
562 which were incorrectly assigned by the cc.
563
564
565 ;callisto
566
567 * added a filter again which was was removed in the last release.
568 it removed the most brightest events. This should not change
569 any analysis result because these events are so bright that
570 they cannot be analysed anyway, but the bad-pixel plots doesn't
571 show outliers.
572
573 * updated muon calibration constants for the periods 51-57,
574 58-63 and 67-
575
576 ;star
577
578 * The camera currents are now displayed with the rate of the camera
579 reports instead of the caco reports
580
581 ;ganymed
582
583 * if mc camera files are new enough (>=8) the source position in the
584 camera is now calculated from the stored telscope and shower
585 orientation (Note, that this might not be suitable in all cases
586 depending on the aim of the study. These case still needs
587 implementation)
588
589
590
591== Version 2.1 (2008/06/18) ==
592
593 ;Database
594
595 * introduced average temperature and wind speed from star-files
596
597 * introduced average values from Pyrometer (mainly Cloudiness)
598
599 * introduced the ratio of accepted calibration events in the
600 calibration run
601
602 * introduced the average rates of the different trigger pattern,
603 e.g. the rate of pedestal and calibration events, from the signal-file
604
605 ;general
606
607 * fixed GroupBy options in plot*.C macros
608
609 * only display KVA points (not the Tuorla points) in plotoptical.C
610
611 * all programs now allow to add resources to the ones from the resource
612 file or overwrite them from the command line. This can be done like this
613 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
614 if something seems to be wrong you can debug what the program is doing
615 using the option --debug-env=3
616
617 * increased the diversity of debug levels. That also means that with -v3
618 you get now less output, i.e. only the output which is important for
619 an analysis. To get more output which helps for debugging try 4, 5 and 6.
620
621 * fixed a problem in the task synchronizing the reading of the reports
622 and the data stream. The effect was that in some circumstances the last
623 events of some trees could have been skipped. Since this is only a
624 very tiny part of the data no severe effect to your analysis results
625 is expected (an exception might be very short, i.e. singel runs,
626 datasets).
627
628 * Dataset file now allow to include the sequence file directly within
629 the dataset file and also allow to exclude single runs from the dataset.
630 (for more details see Class reference of MDataSet)
631
632 * Sequence files now allow for excluding runs from the analysis
633 (for more details see Class reference of MSequence)
634
635 * added code to process the sum-trigger flag
636
637 * the histogram classes MH3 and MHn now support profile histograms
638
639 * the histogram classes MH3 and MHn now support labels at the axis
640
641 * the Random Forest Train-classes (MJTRain*) now store the used datasets
642 in the output file
643
644 * the MFMagicCuts have a new option to allow a linear area cut (for
645 special studies)
646
647 * The liniking of the shared object is now done into a file defined
648 by 'mktemp'. This should be a local file system which accelerates
649 liniking a lot.
650
651 * The code has been prepared for compilation with root 5.18/00d
652
653 * The MHEnergyEst histogram now shows the distribution of
654 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
655 and (Eest-Emc)/Emc vs Emc.
656
657 * fixed mars (event display) for merpped raw-data and MC data
658
659 * adapted the synatx of sequence files to allow for the new run/file
660 scheme. For more details see class description of MSequence
661
662 ;showplot
663
664 * Added support for tiff files
665
666 * Added support for csv files (tables containing tab number,
667 name and title)
668
669 * Tabs now can have a title which is displayed in the postscript file
670
671 * When multiple file are written at once (e.g. pngs from a display)
672 it is now possible to use the tab name and or tab number in the
673 file name. For details see showplos's help.
674
675 ;merpp
676
677 * Implemented cc file version 2008-02-20/0
678
679 * Implemented cc file version 2008-05-19/0
680
681 * With new options merpping can be restricted (in addition to the
682 run-number) also by telescope and file number.
683 For details see "merpp --help"
684
685 * Implemented raw data format 11 (the most important change, except
686 from plenty of changes in the format definition, is the addition
687 of the file-number in the header) If nobody makes a mistake this
688 format should have the advantage that it is by definition forward
689 compatible, so old programs will be able to read newer formats.
690
691 * Added Pyrometer information to default output (stored in a new Tree
692 Pyrometer, needs a complete new merpp, i.e. new calibration)
693
694 * Merpping (also update) can now be restricted to one single report.
695 For example:
696 If you want to update an old file with Pyrometer information call
697 merpp --only=Pyrometer --update
698
699 ;callisto
700
701 * in the pedestal processing now at least 50 processed events are
702 required for succeeding.
703
704 * the signal and calib files now contain also the sequence information
705
706 * the two MPedestalCam in the calib file now have proper names
707 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
708
709 * Both pedestal cams now contain the number of events processed
710
711 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
712 i.e. for the extraction of the calibration pulses basically the average
713 over all events of the first slice instead of all slices was used.
714 Since pedestal and calibration constants are continously recalculated
715 this only effected the very first events of every sequence.
716
717 * For the extraction of the position of the maximum sample now the
718 extraction range is set automatically to the extraction window,
719 before the whole accessible range was used.
720
721 * If the number of samples in the events and the number of samples
722 in the run-header disagrees now an error is raised (this can
723 happen in not well simulated Monte Carlo files)
724
725 * In the case of MUX-data pedestal events with the lvl1 trigger flag
726 could survive into the pedestal calculation -- fixed.
727
728 * Tab "TrigPat" added showing the distribution of the trigger pattern
729 as found in the run-files (normalized with the run length)
730
731 * The selection of events from the trigger pattern has been improved.
732 If the trigger pattern is corrupted events won't pass anymore.
733
734 * Added a new command line option --dev-null to suppress output of
735 Y-files (this is useful for test cases)
736
737 * added a new tab "CalPos" showing the arrival time of extracted
738 interleaved calibration events
739
740 * Using the new --test switch you can now calibrate the calibration
741 file
742
743 ;star
744
745 * the star file now contains also the sequence information
746
747 * Added a new command line option --dev-null to suppress output of
748 I-files (this is useful for test cases)
749
750 * Tab "Rate" added showing the distribution of the trigger pattern
751 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
752 the Y-files (normalized with the run length)
753
754 * The effective on-time calculation doesn't use events with only
755 sum-trigger anymore
756
757 * The data in the MHWeather tab has been reorganized. The never
758 working solar radiation has been removed and the data from
759 the pyrometer (cloudiness, air and sky temperature) is
760 displayed in addition.
761
762 ;ganymed/sponde
763
764 * Now data points are even shown correctly if they have error bars larger
765 than one sigma. Points with null or negative significances are omitted.
766
767 * DrawNicePlot now allows to set a projection range
768
769 * Updates pointing models. One is applied after the implementation
770 of the new LUTS in August, the other one is applied after the
771 next major change of the pointing model in October. Note that
772 these models are preliminary and give wrong results below Zd=65deg
773
774 ;sponde
775
776 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
777
778 * a new option "--force-runtime" is available. In case of very short
779 datasets (for light-curves) which are in the order of a few
780 minutes the calculated effective on-time is not very acurate because
781 it is quantizised in the order of a minute. Therefore you can switch
782 to using the real run-time instead (remakrt: this ignores any
783 dead-time!)
784
785 * a more analytical way is used to "fill" Monte Carlos into regions
786 of impact parameters which have not been simulated because the
787 trigger efficiency is assumed to be 0.
788
789 * estimated sensitivity curves for hi and lo zenith angles are shown
790 scaled to the correct observation time and collection area
791
792 * the Monte Carlo events after cuts are now written to the output file
793 if an output file given
794
795
796
797 *** Version 2.0 (2007/09/03)
798
799 - database: the position used for the pulse pos check was missing
800 in the callisto output and could thus not be filled into the DB.
801 Also the old values seemed not exactly the PulsePos used for
802 teh check.
803
804 - general: Resource file now allow an Include-Resource, i.e. you can
805 read a resource file with default settings, include it in your
806 resource file and overwrite the settings in your file. More than
807 one include file is allowed. Inclusions can be iterative.
808 Include: mydefaults.rc yourdefaults.rc
809 The resources in the first file have higher priority than the
810 second file.
811
812 - general: Now the output files (calib*.root, etc) also contain the
813 resource file (to check it open it in the TBrowser and choose Print()
814 from the context menu)
815
816 - general: Dataset files now allow to overwrite the default path
817 to search for sequence and data files. Note, that the program
818 option and individual resources will overwrite it. For example:
819 SequencePath: /magic/montecarlo/sequences
820 DataPath: /magic/montecarlo/star
821
822 - general: Fixed a problem with variables in MDataPhrase. It seems
823 that only optimdisp (didn't work) was effected.
824
825 - general: Some improvements to the optim and train processing. For
826 example the ststud window now got a proper title.
827
828 - general: The "Status Display: " was removed from the window title
829 within an Eventloop.
830
831 - general: added a new flexible histogram-class (MHn) which can be used
832 for example in testing after optimizations or training to produce
833 user defined histograms.
834
835 - general: The Random Forest now allows attaching an evaluation
836 function which is applied to its output. This allows to train
837 on whatever you like (eg. train on log10(energy), but return
838 energy)
839
840 - general: The Random Forest training of energy (trainenergy.c) and
841 disp (traindisp.C) has been improved by more graphical output to
842 judge the result.
843
844 - general: The training of energy (trainenergy.C) has been improved
845 a lot by training on a different quantity than energy. It gives
846 a result which is highly independant of the source spectrum
847 and shows lower bias than all other options.
848
849 - general: Dataset files are allowed to contain collections of
850 datasets. For more details see the class reference of MDataSet.
851
852 - general: The default WobbleMode in a datset file now (if not
853 overwritten) is "auto", i.e. wobble mode is set if the dataset
854 doesn't contain off-sequences.
855
856 - merpp: Merpp can read file format version 9 now. Please realize
857 that for file format version 9 the extraction range is different
858 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
859 the first and last 15 slices have been removed from all MUX data.
860
861 - mars: Similar to writing movies you can now select events which
862 should be displayed in your display. Therefore add the following
863 lines to your mars.rc:
864 MFEvtNumber.FileName: ganymed00223552.root
865 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
866 The input file can be a ganymed-file after (ganymed*.root) or
867 before (ganymed*-summary.root) file. For example to select all events
868 from your on sample after cuts (excluding the ThetaSq cut) use
869 MFEvtNumber.Selector: DataType.fVal>0.5
870 To show all events from your on-sample after quality cuts
871 use the summary file instead.
872
873 - mars: new ways to call mars are implemented. Instead
874 of calling
875 mars filename.root
876 you can now also use
877 mars sequence.txt
878 or
879 mars sequence.txt inputpath
880 or replace sequence.txt by the sequence number if the default
881 sequence file should be used.
882
883 - mars: The default size has been increased
884
885 - mars: There are two new heckboxes which allow to switch off
886 the calculated image parameters
887
888 - callisto: was broken for MCs... fixed.
889
890 - callisto: improved calculation of spline coefficients a lot. This
891 leads to a further improvement of the event rate calibrating MUX
892 data of about 15% (175evt/s instead of 150evt/s)
893
894 - callisto: finally the raw data we read is now real 16bit (with
895 10bit precision) for MUX data and not a stripped 8bit number
896 anymore. Due to scaling of the numbers (without precision loss
897 into an [0-256[ range, the final numbers for pedestal, pedestalrms
898 and extacted signal don't change. However, at all places where
899 raw data is directly accessed (eg. saturation and variation
900 limits in the signal- and pedestal-extraction) the numbers
901 refer still to the data's 16bit range.
902
903 - callisto: The maximum arrival time difference used in the bad
904 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
905 for both, old FADC and MUX-FADC, data.
906
907 - callisto: Be aware that callisto is now calibrating the arrival time
908 in nanoseconds rather than time slices. Also all following tasks
909 have been changed to assume ns units now. If you star data
910 calibrated with an older version it might be necessary to adapt
911 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
912 to obtain optimal results. The plot in the PulsePos tab
913 will now be in ns, too. This might also mean that the Muon
914 analysis in star might not work as perfect as expected as long
915 as old files read in.
916
917 - callisto: The calibration constants of earlier updates got lost
918 somehow. All constants have been updated.
919
920 - star: The PSF is now determined from the profile of the ArcWidth
921 instead of arcwidth/radius. The old way gave to much weight
922 to the bins with low statistics. The reference lines have been
923 updated.
924
925 - star: For speed reasons events suitable for the muon analysis
926 are now also preselected by fConcCOG<0.1 which seems to be a very
927 good preselector for muons.
928
929 - star: is now calculating a new timing parameter the Slope along
930 the major and minor axis of the shower. Therefore a numerical
931 solution of a line-fit is used. To use MHillasExt.fSlopeLong
932 and MHillasExt.fSlopeTrans don't forget to multiply it with
933 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
934
935 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
936 have been removed from MNewImagePar. They have never been good for
937 anything.
938
939 - star: Implemented a new recursive algorithm which is supposed to be
940 faster. Also implemented new cleaning oiptions, which are:
941 + CleanLevel0:
942 The cleaning level above single core pixels can be kept
943 + KeepIsolatedPixels:
944 Define whether single core pixels should be kept
945 + TimeLevel1:
946 The coincidence window in nanoseconds to single used neighbors
947 + TimeLevel2:
948 The coincidence window in nanoseconds to two used neighbors
949 + PostCleanType:
950 MOde in which a time dependent post cleaning should be applied
951 0: No post cleaning
952 1: Require for each used pixels at least one used neighbor
953 within a time-window of CleanLevel1
954 2: Require for each used pixels at least two used neighbor
955 within a time-window of CleanLevel2
956 3: Require first two and second one used neighbor
957 within a time-window of CleanLevel1 and fCleanLevel2
958 respectively
959 + RecoverIsolatedPixels:
960 - recoveres isolated core pixels if they have a used neighbor
961
962 - mars/star: The new default cleaning is:
963 + CleanLevel1: 6.0
964 + CleanLevel2: 3.0
965 + CleanTime1: 1.75
966 + CleanTime2: 1.75
967 + PostCleanType: 3
968
969 - star/ganymed: The old spark-cuts have been replaced by new ones.
970 These new spark cuts have been cross checked with the sequences
971 84720 (before splitter), 101041 (after splitter) and 223539 (new
972 FADCs). In all cases they seperate pretty well, but of course not
973 perfect. Monte Carlos have suggested to tighten the cuts a little
974 bit further at low sizes. This has been done.
975
976 - ganymed: IMPORTANT - The spark cuts have been changed to match
977 all available data more or less well. This might mean that for
978 YOUR data there are still sparks visible.
979 Whenever you do an analysis you have to make sure that NO sparks
980 survive your cuts!
981
982 - ganymed: The old hadronness and size cuts have gotten new indices
983 (10, 11). The old indices 8 and 9 now mean an additional condition
984 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
985 If you want to switch off this cut just move the line far away enough,
986 e.g. by setting c[9] to -500. Please update your ganymed.rc files
987 accordingly!
988 The unit of c[9] is deg. It is the dist at which your cut will
989 cross the slope==0. The unit of the slope is ns/deg. So if
990 you readin files calibrated with an older Mars-version you
991 have to adapt the default value for c[9] to the FADCs:
992 - Multiply by two for the MUX FADCs (run number > 200.000)
993 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
994 - Multiply by 42 for the meaning of life (run number = 200.000)
995
996 - ganymed: The old Cut0 is now called CutQ and is calculated before
997 the source position is caluclated. If you need a quality cut
998 including source dependant data (be very carefull with this!)
999 you have to use Cut0 instead.
1000
1001 - ganymed: now properly supports three off regions in wobble mode.
1002 It will be the default from now on in ganymed_wobble.rc. To change
1003 the number of off-regions use
1004 NumOffSourcePositions: 1
1005 in your ganymed.rc. Also by default no off-theta cut will be done
1006 anymore so that you will get a background level higher than the
1007 signal level in your ThetaSq plot for ThetaSq>0.2.
1008 Due to this be carefull changing the scaling mode away from
1009 "None". You will underestimate your signal if your scale interval
1010 is not properly set.
1011 (Rem: ThetaSqN is no longer needed)
1012
1013 - ganymed: is now storing the events of all (on- and off-)
1014 source positions even in the case of more than one off-source
1015 position. This should allow sponde to work properly and the
1016 energy estimation is done correctly in all cases (without any
1017 "nearest position" trick)
1018
1019 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
1020 with a real pointing model for the starguider is done, calibrated
1021 with more than thousand tpoints taken from this date on.
1022
1023 - ganymed: was broken for Wobble-MCs... fixed.
1024
1025 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
1026 has changed. Note that your old ganymed.rc will be incompatible
1027 with the new algorithms! Please check the ganymed.rc files and
1028 the class description of MFMagicCuts for more information.
1029 It is recommended at the moment to use identical Disp-Parametrizations
1030 for on/off- and wobble-mode. If cuts are optimized only
1031 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
1032 should be optimized. All other values should be kept as they are.
1033 If you want to do an anylsis without timing a parameters, you can
1034 switch off the timing cuts by seeting parameter 7 to a very small
1035 value (eg. -99). To remove the slope parameter from the disp
1036 paremtrization set parameter 8 to 0.
1037
1038 - ganymed: The distribution of observation time versus zenith
1039 angle is now shown for off- AND on-data.
1040
1041 - ganymed: The contents of the source position plot are no longer
1042 averaged, thus a lot of (fake) events between the two wobble
1043 positions have disappeared.
1044
1045 - ganymed: There is a new tab "CutT" it contains the VsSize plots
1046 with the CutT, whihc is defined in ganymed.rc, applied. It
1047 is resonable to use your theta-cut for it, to see if there is
1048 something strange (sparks!) in your signal-region.
1049
1050 - ganymed: To choose a dataset from a collection in a dataset file
1051 use the new command line option "--dataset=12345"
1052
1053 - optim, sponde: should now properly support three off-regions.
1054 Just produce your ganymed summary files with three off-regions.
1055 optim and sponde will automatically get all off events from
1056 all off-regions from this file. Please do not forget to
1057 set the scaling in optimwobble.C properly:
1058 fit.SetScaleUser(1./3);
1059 it is not yet read in automatically (will follow soon).
1060 In the case of fixed Scale you can also use
1061 cuts.SetThetaCut(MFMagicCuts::kOn);
1062 no off-cut needed.
1063 Be carefull in case of three off-regions when switching on
1064 scale mode. Make sure that the scale interval is set correctly.
1065
1066 - sponde: sponde.rc and sponde_onoff.rc are now idetical
1067
1068 - sponde: the resouce files have been rewritten with a lot of
1069 comments and a well working parametrization for an energy estimator
1070
1071 - sponde: In the estimated energy versus monte carlo energy plot the
1072 contents where exchanged.... fixed.
1073
1074 - sponde: the so called "accurate"-mode has been removed. It didn't
1075 give any improvement in accuracy, only decreased execution speed.
1076
1077 - sponde: the so called "simple"-mode has been removed. It didn't
1078 give any improvement in simple.
1079
1080 - sponde: the so called "refill"-mode has been removed. It was anyhow
1081 not implemented.
1082
1083 - sponde: now checks whether the theta distribution of your on-data
1084 and the theta-distribution of your Monte Carlo sample (after
1085 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
1086 sample is incomplete) execution is stopped. Execution can be forced
1087 using the new option --force-theta. Use this option with care!
1088
1089 - sponde: Proper collection areas can now be constructed also from
1090 Monte Carlo samples generated with different maximum impact
1091 parameters. Note that in previous version you neither got
1092 a warning or failure, nor was there any obvious sign that the
1093 collection area was overestimated due to usage of files with
1094 different maximum impact parameters.
1095
1096 - sponde: If MC files with different lower energy limits are used
1097 the primary MC spectrum is artificially completed down to the
1098 lowest energy used at all. WARNING: that this gives correct
1099 collection areas ONLY if none of the events in this region would
1100 survive your cuts at all.
1101
1102 - sponde: the output file now contains more information about
1103 the spectrum (eg. the full 2D collection area histogram).
1104 Note, that this information can only be written to the file
1105 if it is stored automatically via command line argument.
1106 If you only store the status display from within the display
1107 the information is lost.
1108
1109 - sponde: added a new tab "Disp". It shows the residual of the disp
1110 (Disp-Dist) versus several parameters and it is meant to judge the
1111 quality of the disp estimator. In the ideal case the residual is zero
1112 and doesn't depend on any variable. The tab is displayed after
1113 CutQ and Cut0.
1114
1115 - sponde: added a new tab "Energy". It shows the residual of the
1116 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1117 several parameters and it is meant to judge the quality of the
1118 energy estimator. In the ideal case the residual is zero
1119 and doesn't depend on any variable. In reality even a good estimator
1120 can show residuals versus Monte Carlo energy. The tab is displayed
1121 after all cuts.
1122
1123 - sponde: added a new tab "EventDist" showing the unweighted real
1124 absolute number of events of your sample after cuts. This tells
1125 you how many events with this energy you had in your MC files.
1126 The same information you get from the error bars of the weighted
1127 histograms, but this is less intuitive.
1128
1129 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1130 for comparison. It is not meant to show these curves in
1131 publications, they are only for production.
1132
1133 - sponde: The OriginalMC tree with the events produced by corsika
1134 is now processed only once
1135
1136 - sponde: Finally fixed most annoying bug, which has effected the
1137 last bin of the collection area. It was the problem that binnings
1138 of root histograms are from 1 to n (included) but there was a C-like
1139 loop in sponde from 0 to n (excluded). Now the loop also includes
1140 correctly under- and overflow-bins. The worse thing with this is,
1141 that for the events in the highest bin not only the bin-content
1142 was wrong, but also the weights applied to these events, which could
1143 in pricipal effect also other parts of the distribution (eg. due
1144 to energy estimation). Fortunately it effected only a few events
1145 in most cases.
1146
1147
1148
1149 *** Version 1.2 (2007/05/14)
1150
1151 - database: The database now has two new values Unsuitable50 and
1152 Unsuitable01. They express the number of pixels which are
1153 unsuitable for more than 50%, respectively more than 1%, of
1154 all calibrated event. It is a more accurate number than the
1155 previously used numbers, because they only take the first
1156 calibration (ignoring the interleaved calibrations) into account.
1157
1158 - database: The database now has two other new values UnsuitableMax and
1159 DeadMax. They express the maximum number of pixels which were
1160 unsuitable, respectively dead, during the sequence. Because
1161 of high pedestal rms (cars passing) a few events with very high
1162 numbers of unsuitable pixels can happen. Not to suffer from this
1163 effect we don't take the highest 0.1% of the numbers into account.
1164
1165 - general: fixed a bug which caused callisto and star to stop working
1166 properly because the callisto output was currupted
1167
1168 - general: a script called scripts/makemovie has been added which
1169 simplified the process of producing several movies from a single
1170 sequence with different setup.
1171
1172 - callisto: Some more code cleanup. Started to remove old obsolete
1173 code from cvs.
1174
1175 - callisto: The extraction of the pedestal with the extractor was
1176 not random. It seems that extracting at one position is still biased
1177 (for example in the first or last slices we could still suffer from
1178 switching noise) Now it is completely random.
1179
1180 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1181 pedestal files) individual pixels could be skipped due to high
1182 variations. This was already the case for the pedestal extraction
1183 from the lo-gains since the beginning and properly handled
1184 there, but was introduced in the extraction from the pedestal files
1185 a while ago. To calculate the average value it was still divided
1186 by the number of events procesed not by the number of summands
1187 really summed. This let to a pedestal which was a tiny amount too
1188 small (for a few piels in the order of 0.1%). This led to an slightly
1189 positive offset of the randomly extracted pedestal for a few pixels.
1190 I doubt that this has a big effect on the result, because the effect
1191 on the individual numbers is quite small. Due to this it is suggested
1192 that you rerun your calibration to make sure you are without any
1193 avoidable bias.
1194
1195 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1196 the median rms of the absolute arrival time and expressed in significance
1197 levels. This replaces the old meaning of an abolute upper limit. An
1198 absolute upper limit doesn't make much sense, because in our data
1199 all arrival times are shifted at the same time (in fact it might be
1200 a shift of the artificial trigger w.r.t. to the light flash).
1201
1202 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1203 of the number of unsuitable pixels over the whole sequence. This
1204 is usefull mainly to judge if an intermediate calibration had
1205 problems.
1206
1207 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1208 of the number of dead pixels over the whole sequence. Dead pixels
1209 in this context are unmapped pixels, i.e. pixels which could not
1210 be interpolated, and thus are ignored in the further analysis.
1211
1212 - callisto: It is now possible to use the position of the maximum
1213 of the spline as arrival time instead of the leading edge even
1214 when using the integral for the signal. Therefor set the extraction
1215 type to kIntegralRel ("IntegralRelative") and the relative height
1216 ("HeightTm") to -1:
1217 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1218 MJPedestalC1.ExtractSignal.HeightTm: -1
1219
1220
1221
1222
1223 *** Version 1.1 (2007/04/27)
1224
1225 - general: The new class MGeomCamDwarf contains the camera geometry
1226 for our prefered Dwarf camera and can be used to create general
1227 geometries of roundish or hexagonal cameras.
1228
1229 - mars: The default cleaning is now abolute 8.5/4.0.
1230
1231 - mars: The resource file mars.rc now contains examples for MUX data
1232
1233 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1234 data containing only 10-bit information is still cooked down to
1235 8-bit, by cutting away the lowest 8-bit.
1236
1237 - merpp: When reading raw data the data is now stored in a single
1238 array. The lo-gain array is obsolete. The interface stays the same.
1239
1240 - callisto: To process the new MUX data use the resource file
1241 callisto_mux.rc
1242
1243 - callisto: The -root and -raw options to read merpped raw data have
1244 been removed
1245
1246 - callisto: If the -mc option is given the sequence-name can now be
1247 replaced by the MC sequence number
1248
1249 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1250 -mc option can now be omitted
1251
1252 - callisto: Started further simplification by removing obsolete
1253 dependancies on MCalibIntensity*Cams.
1254
1255 - callisto: removed unsused intensity calibration from MJCalibration
1256 for further simplification
1257
1258 - callisto: for simplification removed references to
1259 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1260 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1261 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1262 (this should at minimum change nothing at all, and at maximum
1263 improve thing if these containers where somewhere not handled
1264 properly)
1265
1266 - callisto: Added the option to write an event movie. Please use
1267 this option with care (huge files) but exessively to understand
1268 our events. For further documentation please refer to the
1269 IACT wiki
1270 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1271
1272 - callisto: Improved binning for the pulse position check histogram
1273
1274 - callisto: The code calculating the pulse position checknow takes
1275 the pedestal into account
1276
1277 - callisto: The arrival time is now stored with full precision this
1278 helps to get rid of artefacts in histograms. For the signal this
1279 is not necessray because it is displayed in log-scale anyhow
1280
1281 - callisto: Fixed a problem with internal exclusions. Pixels which
1282 have once been marked as unsuitable didn't get the necessary
1283 histograms filled anymore to be rechecked with each interleaved
1284 calibration.
1285
1286 - callisto: The relative arrival time resolution (the rms of the
1287 relative arrival time offset) is now checked against its
1288 median and the median deviation, instead of the average
1289 plus an absolute offset.
1290
1291 - callisto: The relative arrival time offset is now calculated
1292 w.r.t. its median not w.r.t. to an artificial reference pixel.
1293
1294 - callisto: The relative time calibration now marks pixels with
1295 outlaying offset as unsuitable
1296
1297 - callisto: The interleaved relative time calibration has been switched
1298 on. The advantage is that pixels which are marked as outliers
1299 now can recover. An improvement over time is not expected, because
1300 the relative time calibration seems stable.
1301
1302 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1303 option can now be omitted.
1304
1305 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1306 or the option "-mc" is specified as default the monte carlo datacenter
1307 paths (/magic/montecarlo/...) are used if not overwritten in the
1308 dataset file.
1309
1310 - ganymed: The output files now contain run- and event-number for all
1311 events, accessible as RunNumber.fVal and EvtNumber.fVal
1312
1313 - ganymed: Added a plot showing the source position in the camera also
1314 for wobble mode
1315
1316 - ganymed: In addition to the existing task which can be setup to
1317 be executed after Cut1 a final task called "EstimateEnergy"
1318 has been added, executed before writing the final output
1319 (ganymed00000000.root). The task setup in all three cases
1320 can be choosen individually. (For all three(!) cases you
1321 can for example choose MRanForestCalc. For examples see all
1322 sponde*.rc and all ganymed*rc)
1323
1324 - ganymed: If a container "MEstimatedEnergy" is found in the
1325 parameter list (eg. because it was setup by MEstimateEnergy)
1326 it will be written to the output file.
1327
1328
1329
1330 *** Version 1.0 (2007/02/16)
1331
1332 - database: Website to plot values from the database has been added.
1333
1334 - database: The rate of spark events as found by star is now kept
1335 and the rate after cleaning is now with spark events subtracted
1336
1337 - general: The changes to the interpretation of phrases lead to
1338 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1339
1340 - general: Added example files how you can create your own calendar
1341 (eg. as christmas present) with Mars. Just run
1342 root macros/tutorials/calendar.C
1343
1344 - general: Added a possibility to display grouped data in the plotdb.C
1345 macro (and similar macros). This allows to plot hourly, nightly,
1346 weekly, monthly and yearly averages.
1347 For more details see the plotall function of the macro
1348
1349 - general: fixed the error display of the camera display. It showed
1350 wrong results.
1351
1352 - general: fixed a memory leak when reading many MStatusDisplays
1353
1354 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1355 between a spherical and a parabolic mirror
1356
1357 - callisto: We have a new pulse position check which takes the properties
1358 of the extractor automatically into account. So no need to set
1359 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1360 left is done. If possible the lo-gain extraction start and hi-gain
1361 extraction end is changed accordingly. If no proper extraction range
1362 can be set (hi-gain too much to the left) an error is raised.
1363
1364 - callisto: New swapped pixels have been found and corrected
1365
1366 - callisto: Redone the signal extraction this includes:
1367 + Unified the algorithms to extract the pedestal for all pedestal
1368 extractions done
1369 + Unification of hi- and lo-gain into one array
1370 + Unification of hi- and lo-gain extraction for Spline and
1371 Digital Filter (means now exactly the same algorithm is used,
1372 not a copy-and-pasted one)
1373 + Store pedestal subtracted data in a common place
1374 + Improved extraction algorithms. If the algorithms search a
1375 maximum but don't find one they don't return the maximum anymore
1376 + Improved the extraction such that a information for signal
1377 and time which is consistent is returned
1378 + replaced the numerical spline with a (not slower) analytical
1379 solution
1380 + Lowered the saturation limit from 250 to 245 to make sure that
1381 we are far away in all pixels from problems with the clock-noise
1382 + The start of the lo-gain extraction is calculated from the hi-gain
1383 arrival time. In case of saturation an estimation is used.
1384 + the hi-gain window was extended to slice 16. This allows extraction
1385 of very late pulses in single pixels or of huge hadron showers.
1386 + Now uses the lo-gain extraction range for pedestal extraction,
1387 not the hi-gain range in the lo-gain
1388
1389 - callisto: New hi-/lo-gain calibration constants have been produced
1390 for all periods from the statistic of the whole period. They are
1391 now used automatically depending on the periods. The old constants
1392 where deviation in avarega about 2%-3%. The constants are very
1393 stable from period to period (<<1%) except for exchanged channels.
1394 In a few cases the constants used so far were off by 1%-2% (maybe
1395 temperature effects?)
1396
1397 - callisto: To gain obsolete space we do not write the
1398 MPedestalFundamental anymore. Also calibration and bad pixel
1399 treatment is not done for it anymore because it has never been used.
1400
1401 - callisto: Fixed a bug in the seuqence handling which caused the
1402 light condition to be ignored
1403
1404 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1405 basically the same as "Cleaned" but the distribution devided into
1406 the events fullfilling a spark cut or being rejected by it.
1407 This cut can be changed from star.rc (see example inside) by
1408 the "SparkCut" directive
1409
1410 - star: Star displays now the average individual pixel-rate (IPR) versus
1411 time and the average discriminator threshold (DT) of all pixels.
1412
1413 - optim: fixed a problem with the optim-macros which was due to a bug
1414 in the new phrase parsing
1415
1416 - ganymed: To get a nice FalseSource plot (instead of the all-information
1417 debug plot displayed as a standard plot) use the context menu
1418 somewhere between the two upper plots, click on "DrawNicePlot"
1419 and enjoy the result. (It is the same context menu which contains
1420 the other options)
1421 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1422
1423 - ganymed/optim/train: The cut program, trainings- and optimization
1424 macros could run with less files found than expected from the
1425 sequence-files. No the execution is stopped in this case.
1426
1427 - ganymed: now stores the dataset in the output file with all information
1428 contained (as sequence number, sequence path, data path) so that the
1429 used dataset file can be recreated complete from the output
1430
1431 - sponde: now also allows the uasge of random forest
1432
1433 - sponde: added a plot showing the cut efficiency
1434
1435 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1436 errors (eg. effecting the collection area) because the errors of the
1437 two histograms were swapped in the calculation, which makes a difference
1438 in the case the histograms contains weighted events. Aditionally the
1439 totalarea was incorrectly taken into account, which results in too small
1440 errors, which makes a difference at low statistics were the errors
1441 or the collection area dominate.
1442
1443
1444
1445 *** Version 0.10.3 (2006/10/23)
1446
1447 - database: Implemented ObservationMode flag in websites.
1448
1449 - database: For sequences there is now also the stoptime available on the
1450 websites.
1451
1452 - database: Removed ManuallyChanged flag from sequence-info websites,
1453 as it is not needed anymore with the new sequence building algorithm.
1454
1455 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1456 Class for calculation of confidence intervals (upper limits).
1457 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1458 Please read the class instruction of TRolke for more information.
1459
1460 - general: The programs now return 0xfe if the requested resource file
1461 doesn't exist.
1462
1463 - general: Errors comming from root itself are now not output to
1464 stderr anymore but to our default (colored) log-stream.
1465
1466 - general: Changed the interface to TFormula such that now everything
1467 is parsed by TFormula, which should allow to use phrases even
1468 without paranthesis correctly parsed.
1469
1470 - callisto: replaced the AdHoc number of effective integration slices
1471 in the digital filter by an average of the correct number, averaged
1472 over all possible set of weights. This also gives correct numbers
1473 for the lo-gains which were totally wrong before.
1474
1475 - callisto: drastically reduced memory consumption by not storing
1476 all intermediate calibration results in memory anymore (we might
1477 write them into a file in the future)
1478
1479 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1480 debug plot displayed as a standard plot) use the context menu
1481 somewhere between the two upper plots, click on "DrawNicePlot"
1482 and enjoy the result. (It is the same context menu which contains
1483 the "DrawAll" option)
1484 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1485
1486
1487
1488 *** Version 0.10.2 (2006/10/15)
1489
1490 - general: changed the building of the sequence files such, that
1491 the source-/project name in case of wobble-sources is not the
1492 source/project of the first data run anymore but the new generalized
1493 wobble source/project
1494
1495 - general: Added some functions to MAstro to calculate sun and
1496 moon properties
1497
1498 - general: Added two new macros (starvisday.C and starvisyear.C)
1499 which allow to plot the visibility of several stars in one day
1500 or of one star along one year
1501
1502
1503
1504 *** Version 0.10.1 (2006/10/11)
1505
1506 - general: HTML logging output was distorted... fixed.
1507
1508 - general: Changed the writing of the sequencefiles such that only
1509 as many pedestal files as giving at least 1000 pedestal events which
1510 are nearby the first calibration run are used as pedestal runs
1511
1512 - sponde: In the calculation of the collection area(s) and the
1513 distribution for MOnte Carlo and estimated energy the error
1514 calculation was wrong because root didn't take the errors
1515 properly into account... fixed.
1516
1517
1518
1519 *** Version 0.10 (2006/10/10)
1520
1521 - general: all executables now check consistency of the root version
1522 installed with the root version used for compilation. The return
1523 code in this case is 255.
1524
1525 - general: The algorithm to build seqeunces has been redesigned
1526 completly. It is now more flexible in terms of a resource file
1527 resources/sequences.rc which can be used to partly overwrite
1528 the default algorithm and defined the important part of the
1529 algorithm. It also takes correctly into account several ways
1530 of taking wobble-data. Currently the new algorithm doesn't take
1531 the number of pedestal events anymore into account (so a sequence
1532 could have much less than 1000 pedestal events and data runs are
1533 no-more used instead)
1534
1535 - general: a lot of small changes to make the code compatible with
1536 root 5.12/00 and gcc 4.1
1537
1538 - general: Fixed some warnings thrown if more warnings are switched
1539 on in the compiler
1540
1541 - general: Added a function to MMath which returns the Median of
1542 the distribution abs(y[i]-median) but at 68:32 division instead
1543 of 50:50, which is somehow the median counterpart of the rms.
1544
1545 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1546 even if they are compressed with gzip (recommended compression
1547 is with "-1")
1548
1549 - showplot:
1550 + batch mode creation of image files now works with root 5.12/00
1551 + added support for writing bmp (though it never produces
1552 bmp which can be read by programs like xv or gimp)
1553 + added support for xml
1554 + added new option to start the display with a different size, by
1555 --display-width=nnn or --display-height=nnn
1556 + added options to define the canvas size when the display is started
1557 --canvas-width=nnn or --canvas-height=nnn
1558 the option can also be used for batch-mode conversion
1559 + added an option which automatically fits the display size to the
1560 desktop-size: --auto-size
1561
1562 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1563
1564 - merpp: allow the reports to have 1000ms due to a bug in the camera
1565 program.
1566
1567 - callisto: New swapped pixels have been found and corrected. For
1568 details see MRawRunHeader::FixAssignment()
1569
1570 - callisto: Callisto now raises an error if one of the input files could
1571 not be opened.
1572
1573 - callisto: In some rare cases it could happen that in the signal
1574 extraction of the digital filter the extractor returned nonsense
1575 results due a wrong initializion of a variable (this happens in
1576 cases in which the extracted signal is exactly zero or the
1577 digital filter couldn't slide because of a too small extraction
1578 window, which could happen in the lo-gain extraction)
1579
1580 - callisto: The lo-gains have been marked as valid in some cases
1581 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1582 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1583 smaller than the number of slices (fLoGainWindowSize) needed
1584 by the lo-gain extractor
1585
1586 - callisto: Updated absolute calibration constants (muon calibration)
1587
1588 - callisto: fixed a bug which caused the hi-gain saturation not
1589 to be handled properly in the spline (the position of the
1590 saturation was calculated incorrectly)
1591
1592 - callisto: fixed a bug which gave weird results if hi- _and_
1593 lo-gain could not be extracted properly. In some cases hi-
1594 and lo-gain have not been extracted at all and the random result
1595 got calibrated. In other cases the hi-gain was saturating and the
1596 lo-gain has not been extracted. For this a completly arbitraty
1597 scale factor was applied to the result from extracting the
1598 charge of the saturating hi-gain.
1599
1600 - callisto: improves handling of extracted signal if lo- and/or
1601 hi-gain could not be extracted properly. If no appropriate
1602 calibration of either the signal or the arrival time is possible
1603 the pixel is now markes as unsuitable instead of estimated.
1604
1605 - callisto: Fixed a problem in the spline extraction which gave
1606 weird results if the signal was extracted from the first (and
1607 highest) slice (as a workaround extraction from the first
1608 slice has been forbidden)
1609
1610 - callisto: Fixed a bug regarding the use of the QE which doesn't
1611 effect the result because the default is used anyhow.
1612 (The bug was there since 14/07/2005)
1613
1614 - callisto: Changed the default for fgLoGainStartShift to -2.4
1615
1616 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1617 factors to be always 10 for all pixels as soon as the first
1618 calibration update has happend.
1619
1620 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1621 was off by more than one slice (which gives wrong values for
1622 pixels which have saturated the hi-gain) This was a problem
1623 mainly for timing studies, not so much for the automatic standard
1624 analysis. Also the values for the Spline have been changed slightly:
1625 + Digital Filter from 1.70 to 0.95
1626 + Spline from 1.39 to 1.30
1627 The numbers were sorted out by an extensive test in the
1628 test-database.
1629
1630 - callisto: Removed the tab showing the average calibrated arrival
1631 time. It never gave useful information.
1632
1633 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1634 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1635 and both were extracted because the hi-gain was above the
1636 LoGainSwitch.
1637
1638 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1639 lo-gain pulse position (after application of LoGainOffset, which
1640 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1641 have saturated and both were extracted because the hi-gain was above
1642 the LoGainSwitch.
1643
1644 - callisto: After extensive tests a new threshold level for determination
1645 of the pulse position has been found at 50phe. This is due to the
1646 fact that for lower pulses the arrival time changes its average
1647 behaviour dramatically. It tends to the average of the extraction
1648 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1649
1650 - callisto: Added two more plots to the calibration part. The average
1651 extracted signal and the average extracted arrival time as
1652 extracted by the signal extractor (This can help debugging problems
1653 because it doesn't involve a fit)
1654
1655 - star: changed the fit for the effective on time such that initial
1656 values are calculated automatically now instead of using build
1657 in values. This makes the fit more indepedant of the underlaying
1658 rates. With a test of ~350 sequences in the test database it could
1659 be shown that the new fit gives the same result +/-1sek.
1660 The highest deviation was +5s the lowest -10s. You can now control
1661 the bahaviour with two resource values:
1662 MHEffectiveOnTime.FistBin: 3
1663 MHEffectiveOnTime.NumEvents: 12000
1664 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1665 from the resulting gamma candidates
1666
1667 - star: The Center histogram in MHHillas is now by default displayed
1668 with the colz draw-option
1669
1670 - ganymed: now produces valid error codes if failed
1671
1672 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1673 with the option "hadronness" instead of "area" or "both" if
1674 you want to use both cuts. The hadronness cut includes a fixed
1675 cut in hadronness (index 8) and a fixed cut in size (index 9).
1676
1677 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1678 the M3Long of the anti source to be not properly evaluated
1679 (actually is was evaluated as a unique random number) in case
1680 of optimization with anti-theta cut switched on. This might have
1681 lead to improper, but not necessarily wrong, optimization results.
1682
1683 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1684 how to use random forest
1685
1686 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1687 ganymed_onoff.rc. Seems to be unintentional that they were different.
1688
1689 - sponde: Since the introduction of the possibility to define a
1690 normalization energy instead of using the integral the default
1691 was not using the integral anymore but a normalization energy of
1692 1GeV. It is now the integral again.
1693
1694 - sponde: Fixed a problem in the weighting which did not allow
1695 a MC slope of -1.
1696
1697
1698
1699 *** Version 0.9.6 (2006/05/24)
1700
1701 - general: changed the binning of the azimuthal profile of the camera
1702 such that it is aligned with the 60deg boundaries.
1703
1704 - merpp: better handling of problems with the TH, TD part of the
1705 CC-REPORT for files older than 200507190 and 200412210
1706 respectively
1707
1708 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1709
1710 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1711
1712 - callisto: if an arrival time is extracted outside the fadc range is
1713 was set to the boundary before. Now a random number is assigned
1714 instead to avoid unfortunate coincidences of arrival times just
1715 by this arbitrary value.
1716
1717 - callisto: added a new option to callisto.rc which allows
1718 to set the maximum arrival time difference allowed for the
1719 badpixel algorithm to determin whether a pixels belongs to a shower:
1720 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1721
1722 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1723 to 0.9 as suggested by Stefan due to a recent study on the fraction
1724 of pixels surviving the image cleaning
1725
1726 - callisto: switched off error in case of "pulse is too much to the left"
1727
1728 - callisto: The extraction window is not adapted anymore. This means that
1729 the pulse is extracted from the full range. The draw-back is that the
1730 background (pedestal) will become slightly higher. Switching on/off
1731 the PulsePosCheck in the callisto.rc only effects filling the
1732 histograms.
1733 WARNING: If the pulse is too much to the left data is calibrated!
1734 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1735 in the database to make sure that your data is valid!
1736
1737 - star: Show also the number of stars correlated correctly by the
1738 starguider
1739
1740 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1741 than one off-source region in wobble-mode. To use it add the following to
1742 your ganymed_wobble.rc:
1743 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1744 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1745 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1746 + Cut1.ThetaCut: None
1747 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1748
1749 - ganymed: in the case the latest report is older than a default (currently
1750 one minute) and the current report will be skip the starguider
1751 correction and calibration will be reset. The maximum age can be
1752 setup from ganymed.rc by (minutes):
1753 MPointingDevCalc.MaxAge: 1.5
1754
1755 - ganymed: A first implementation showing all size-bins for the theta-sq
1756 resp. alpha-plots in a single tab automatically
1757
1758
1759
1760 *** Version 0.9.5.1 (2006/05/05)
1761
1762 - general: Added a new option "zdiff" to the Makefile which runs
1763 "cvs diff" as "make diff" would do, but with compression
1764
1765 - general: accelerated MTFillMatrix (used for eample in all training
1766 and optimization macros) by skipping some obsolete calles in the
1767 eventloop the first and second loop could be accelerated by ~20%
1768
1769 - general: Added a missing feature in the MFilterList class which
1770 prevented MFEnergySlope from working correctly in trainenergy.C
1771
1772 - general: Accelerated the random forest training and usage a bit
1773
1774 - merpp: Adapted to new raw data file format version 6
1775
1776 - merpp: fixed a problem with reading the starguider reports
1777 after 6.3.2006
1778
1779 - callisto: At some times six pixels had to be exchanged manually in the
1780 data. If the pixels to be swaped are both not found, an error was raised
1781 and calibration was stopped. Now it is assumed they are intentially not
1782 mapped and the Error has been changed to a Warning.
1783
1784 - star: Added new image cleaning based on the arrival time of the shower.
1785 The new cleaning can be accessed using the parameter "Time" instead of
1786 the the old one (like "Absolute) in the star.rc-file.
1787 Recommended parameters:
1788 + MImgCleanStd.CleanLevel1: 8.2
1789 + MImgCleanStd.CleanLevel2: 5
1790 + MImgCleanStd.CleanRings: 2
1791 + MImgCleanStd.KeepSinglePixels: No
1792
1793 - star: Simplified the calculation of the effective on time. By letting
1794 the fit start in the third bin the result should become more stable.
1795 The fit quality is now ignored for the theta-plot which is not used
1796 in the analysis later. Still better pre-cut which, for example,
1797 remove events triggered by car-light (rate changing on a short
1798 time-scale) are missing.
1799
1800 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1801 for optimization (kWeakSource) which is suggested by the Berlin
1802 people for weak sources.
1803
1804 - macros: plotdb.C:
1805 + if no dataset and no time-interval is given only sequences with
1806 an effective on-time above five minutes are plotted anymore
1807 + added a new tab "RelTime" displaying the relative on-time
1808 (effective on-time divided by the observation time)
1809
1810 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1811 the optimization became a lot faster
1812
1813 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1814 To display them just delete the pads displayed on top.
1815
1816 - ganymed: fixed a bug which could cause strange behaviour in wobble
1817 mode if no starguider information was available due to an incorrect
1818 initialization of the starguider calibration
1819
1820 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1821 be changed from within the plot. It can also be setup from the
1822 resource file using:
1823 + MHDisp.fScaleMin: 0.325
1824 + MHDisp.fScaleMax: 0.475
1825
1826 - ganymed, showplot: Fixed a problem with the fit to the off-data
1827 (HistOff) which could cause a time lag or an inifinite loop.
1828 The bug did not effect the results at all.
1829
1830 - sponde: Added a new tab showing the effective collection area after
1831 trigger (including the software trigger)
1832
1833 - sponde: MMcSpectrumWeight has a new option which allows to define
1834 the scaling factor not by the integral of the events but at
1835 a defined energy:
1836 e.g. MMcSpectrumWeight.NormEnergy: 200
1837
1838 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1839 eventloops the loop could be accelerated by ~20%
1840
1841
1842
1843 *** Version 0.9.5 (2006/03/13)
1844
1845 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1846 and added the standard Disp-parametrization
1847
1848 - macros: added a new macro datacenter/macros/plotstat.C allowing
1849 to plot statistics about the data processing
1850
1851 - macros: added a new macro to plot the muon correction coefficients
1852 versus period (macros/plot/mucal.C)
1853
1854 - showplot: path inflation for ganymed files was broken
1855
1856 - callisto: Fixed an important bug. When the number of saturating pixels
1857 were calculated the bad pixel information already available from the
1858 calibration was ignored. This yields wrong values in case pixels
1859 are broken and saturate all the time or randomly.
1860
1861 - callisto: Updated Muon calibration constants. Spline data now also uses
1862 different values for different periods
1863
1864 - star: The time-evolution shown in the effective on-time plot now displays
1865 the axis range (if there are no holes it should be similar to the
1866 effective on-time)
1867
1868 - star: Added two new image parameters:
1869 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1870 the three pixels next to the center of gravity and the size
1871 + MNewImagePar.fConcCore: The ratio of the signals of all
1872 pixels inside or touching the ellipse and the size
1873
1874 - ganymed: now stops in requested source isn't found in catalog file
1875
1876 - ganymed: Many improvements to the phi-plot in wobble mode:
1877 + with a template the ideal background is displayed
1878 + a possible camera inhomogeneity is taken into account
1879 + the anti theta cut is better supported
1880 + the phi cut is automatically calculated from the theta cut
1881 See the examples in ganymed_wobble.rc for more details.
1882
1883 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1884 times the bin-width instead of the absolute energy
1885
1886 - ganymed: New cuts for on/off and wobble mode
1887
1888 - ganymed: The smearing of the False Source plot has been increased
1889 to 0.06
1890
1891 - ganymed: The starguider calibration can now be changed from the
1892 resource file.
1893 See the examples in ganymed*.rc for more details.
1894
1895 - ganymed: added a new option for on-/off-observations
1896 MJCut.RandomSourcePosition
1897 If switched on the distribution of observation time of the source
1898 position in the camera is calculated from the on-data and randomly
1899 applied with this distrbution to the off-data.
1900
1901 - ganymed: by skipping some obsolete calles in the eventloop the
1902 first and second loop could be accelerated by ~20%
1903
1904 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1905 position in the off-data randomly according to its distribution in the
1906 on-data.
1907
1908
1909
1910 *** Version 0.9.4.3 (2006/02/13)
1911
1912 - general: Fixed a bug in most of the programs which prevented the
1913 compile date in the startup message to be displayed
1914
1915 - general: Simplified program calls. The following abbreviations
1916 are now possible:
1917 showlog callisto 55599
1918 showplot signal 55599
1919 star 55599
1920 callisto 55999
1921 ganymed 2
1922 In this cases the corrsponding root-, log-, sequence- or dataset-
1923 filename is automatically compiled using the default datacenter
1924 paths ("/magic/*")
1925
1926 - general: Fixed a long outstanding bug which made axis tick marks
1927 disappear if MDataFormula was used (eg. abs(x))
1928
1929 - general: Updated MMath with new functions to calculate the results of
1930 a exponential, logarithmic and powerlaw fits analytically.
1931
1932 - general: Updated some macros with comments:
1933 + macros/optim/optimdisp.C
1934 + macros/optim/optimenergy.C
1935 + macros/optim/optimwobble.C:
1936
1937 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1938 files) now allows adding a pre-cut like in the optimization. E.g. this
1939 is useful to perform g/h-separation cuts before training the random
1940 forest.
1941
1942 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1943 correctly assigned in the raw data assignement table. A fix to correct
1944 the assignment tabel have been implemented.
1945
1946 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1947 by 90, 180 and 270 deg.
1948
1949 - general: the macro plotdb.C now allows to highlight sequences belonging
1950 to a datset. For more details see the descritions in the macro.
1951
1952 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1953 of the display, it gave wrong results espacially for big sizes.
1954 Now the embedded canvas should always have a ratio width/height=3/2.
1955 The "Size" options have been updated with values fitting the 3/2
1956 size ratio.
1957
1958 - RanForest:
1959 + Updated the random forest classes to support also the
1960 regression method implemented by Thomas H.
1961 + added new tutorial macro how to train the random forest
1962 for energy estimation (macros/optim/rfenergyest.C)
1963 + new classes to train the random forest (still in development)
1964 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1965 + new tutorial macros for random forest training in macros/train
1966 trainenergy.C, traindisp.C, trainseparation.C
1967
1968 - mars: now allows to setup a cut in the resource file mars.rc to choose
1969 the events to be displayed, eg:
1970 Cut.Condition: {0} && {1}
1971 Cut.0: MHillas.fSize>100
1972 Cut.1: MHillas.fSize<900
1973
1974 - merpp: Made aware of the new .rep format 200510250. This includes
1975 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1976 the discriminator thresholds (MCameraTD) and the disciminator
1977 delays (MCameraTD). All of them come with the CC report and are therefor
1978 written to the CC tree.
1979
1980 - callisto: fixed a bug in the calculation of the arrival times in
1981 the Digital Filter. They were all shifted by the same amount
1982 fHiGainFirst. This caused an offset in the order of the position of
1983 the left border of the extraction window in the times calculated
1984 from high-gain and from low-gain. The bug effected only the absolute
1985 arrival times. The bug was there since 30.1.2005.
1986
1987 - callisto: Changed the ExtractionWindow for the pulse position check
1988 such that the camera inhomogeneity becomes as less as possible and
1989 comparable to the pulso position check switched off. More details
1990 on the study will be given at our result web-page.
1991
1992 - ganymed: ganymed.rc, ganymed_onoff.rc:
1993 changed to new cuts trained with 1ES1218 and Crab-data
1994 for maximum sigma*log10(excess)
1995
1996 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1997 a new option was implemented to estimate Disp (CalcDisp)
1998
1999 - ganymed: Implemented two new options which allow
2000 to overwrite the default path to search for the sequence files
2001 --ins=/magic/sequences
2002 and where to search for the image data
2003 --ind=/magic/data/star
2004
2005 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
2006 dx/dy from the resource file by
2007 MSrcPosCorrect.Dx
2008 MSrcPosCorrect.Dy
2009
2010 - ganymed: fixed reading the source catalog. Only as many chars
2011 as the requested source name had were compared (If a source
2012 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
2013 were requested it could happen that the coordinates of
2014 "1ES1218" were read) The source coordinates are now printed
2015 in addition to its name to the logging output.
2016
2017 - ganymed: changed the background fit in the case of a ThetaSq function
2018 from a polynomial to a exponential, this should give a big improvement
2019 for on-only analysis'
2020
2021 - ganymed/sponde: Calculation of the error of single size-/energy-
2022 bins now uses Li/Ma (5) instead of LiMa (17)
2023
2024 - sponde: Added a plot E^2*dN/dE
2025
2026 - sponde: The energy estimator plot should now show values like
2027 they are commonly used.
2028
2029 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
2030 (a powerlaw with cutoff didn't work before)
2031
2032
2033
2034 *** Version 0.9.4.2 (2005/10/01)
2035
2036 - general: added new tutorial macro macros/tutorials/threshold.C:
2037 how to calculate the threshold
2038
2039 - general: added a new game. Start it from the interpreter with
2040 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
2041 and MagicReversi)
2042
2043 - general: neighbor pixels in MGeoms are now sorted clockwise
2044
2045 - merpp: made aware of new format 20050829-0
2046
2047 - callisto: New scale factors from muon analysis, stored in new
2048 resource file resources/calibration.rc
2049
2050 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
2051 the eventloop if something went wrong. This is necessary for the
2052 automatic processing
2053
2054 - callisto: Implemented a new treatment for the time information
2055 developed by S.Ruegamer, this should give much better response than
2056 the old very primitive algorithm. This is especially important
2057 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
2058 treatment was buggy! As neighbor pixels to interpolate the
2059 arrival times always the pixels 0 to 5 were taken)
2060
2061 - callisto: In addition to the new treatment of arrival times the
2062 decision of the treatment whether a pixel contains shower
2063 information or not is used to improve the signal interpolation
2064 further. Previously interpolated pixels showed a non-zero signal
2065 do the peak searching signal extractors. Having a signal pixel
2066 beside raised the signal above the cleaning level. Thus the
2067 pixel survived cleaning to often but with a too low mean signal.
2068 By replacing empty pixels with a gaus (mean and rms from the
2069 corresponding Area entries in MPedPhotCam) this effect can
2070 be supressed.
2071
2072 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
2073 got lost when the events were stored by the calibration... fixed.
2074 (This was no problem for normal image cleaning because the pixel
2075 content was artificially set to 0 not surviving standard cleaning
2076 algorithm)
2077
2078 - callisto: Fixed a bug which caused the random and peak-search pedestal
2079 extracted with an extractor to be exchanged for the first (roughly)
2080 500 events (*Extractor and *ExtractorRndm).
2081 (They were simply exchanged in callisto.cc) This bug might have been
2082 introduced in Mars 0.9.4 when the order of calculation of the two
2083 types of pedestal in callisto got exchanged. The bug only effects
2084 the first seconds of data of each sequence.
2085
2086 - star: Taking the arrival time of Muons into account the calculation
2087 of the parameters could be made independant of the noise
2088 (pedestal rms). The dependance was due to the bias of the peak search
2089 extractor. Now only a ZA dependamcy is left which is not yet fully
2090 understood.
2091
2092 - ganymed: The sequences were still not sorted correctly in any case,
2093 because they were sorted by the full qualified path name. Now they
2094 are sorted by their sequence number.
2095
2096 - ganymed: new values for the spark-event-cut
2097
2098 - sponde: required missing MEnergyEst from ganymed.root... fixed.
2099
2100
2101
2102 *** Version 0.9.4.1 (2005/08/18)
2103
2104 - callisto: fixed some problems with the calibration in case of
2105 inteleaved events. Therefor the final and some intermediate
2106 fits are skipped which would take place on partly filled #
2107 histograms and gave wrong results or failed completely.
2108
2109 - callisto: If the intermediate finalization of the histograms
2110 calculating the mean charge of the calibration signal fails
2111 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2112
2113 - ganymed: Fixed some bugs which caused problems in On-only mode.
2114 Still the false source plot doesn't give reasonable results.
2115
2116
2117
2118 *** Version 0.9.4 (2005/08/05)
2119
2120 - general: Fixed the ZA binning. It did not correctly fit the
2121 MC binning
2122
2123 - general: Added a class to correct for the missfocussing in
2124 April (MSrcPosCorrect)
2125
2126 - general: Random Forest energy estimator should now work properly
2127
2128 - general: MHCamera now displays the profiles in deg instead of mm
2129
2130 - general: MH::SetPalette offers a lot of new palettes
2131
2132 - general: MHillas - the case of CorrXY==0 is now handled properly
2133
2134 - general: implemented the possibility to change the line and
2135 marker style of a sky-grid drawn by MAstroCatalog
2136
2137 - general: Runs in sequences and datasets are now automatically
2138 ordered (it is assumed that the order of their filenames correctly
2139 represents the order of observations) to ensure correct reading
2140 of the subsystem data
2141
2142 - general: Runs cannot be added to a sequence twice anymore. Also
2143 Sequences cannot be added twice anymore to a dataset.
2144
2145 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2146 It gave wrong results by 1./2pi
2147
2148 - showplot: got a new option to start a root interpreter, too
2149
2150 - mars: now displays a rough estimate of Disp and the third moment
2151
2152 - mars: now displays the event time MTime if available
2153
2154 - mars: show muon parameters graphically
2155
2156 - mars: now the file to open can be given as commandline
2157 argument
2158
2159 - merpp: Added support for new arehucas version >= 200507190
2160 implementing values for three temperature sensors in the
2161 counting house (MCameraAUX) and the name of the HV settings file
2162 (MCameraHV).
2163
2164 - merrp: Also fixed some problems with wrong versions numbers stated
2165 by arehucas and implemented some fixed for old versions (<200407070)
2166
2167 - callisto: MCalibrationHiLoCam can now be printed from its context
2168 menu, eg in the TBrowser
2169
2170 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2171 - 1.39 (MExtractTimeAndChargeSpline)
2172 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2173 This is important mainly for timing studies.
2174
2175 - callisto: Changed limits in MHCalibrationChargeCalc from
2176 - -100.125 to -98 (fgChargeHiGainFirst)
2177 - 1899.875 to 1902. (fgChargeHiGainLast)
2178 - -100.25 to -99 (fgChargeLoGainFirst)
2179 - 899.75 to 901. (fgChargeLoGainLast)
2180 Introduced new limits:
2181 - fgNumLoGainBlackoutLimit: 0.05
2182 - fgLoGainBlackoutLimit: 3.5
2183 - fgLoGainPickupLimit: 3.5
2184
2185 - callisto: The handling of automatic weights for the digital filter
2186 has been improved. There are now new calibration weights special
2187 for Monte Carlo calibrations.
2188
2189 - callisto: Updated Muon scale with latest results (1% difference
2190 for most data, 5% for Mar/Apr'05)
2191
2192 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2193 was saturated and the blackout-events in the low-gain exceed the
2194 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2195 This excludes those pixels which have a saturating high-gain
2196 channel, but the low-gain switch does not switch often enough
2197 to make the distribution reliable.
2198
2199 - callisto: fix a bug counting the number of saturated events. Up to now,
2200 the number of saturated slices was counted (which is one for a not too
2201 high number), but for some (pathological) pixels, many more slices
2202 saturated and produced wrong limits.
2203
2204 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2205 + MCalibrationRelTimeCam.CheckFitResults: Yes
2206 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2207 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2208 + MCalibrationRelTimeCam.CheckOscillations: Yes
2209
2210 - callisto: introduce max. number of events for intercalibration,
2211 the rest gets skipped. Default: 4096
2212 The calibration causes too many un-reliable pixels if more
2213 than about 5000 events are treated (@500 Hz) because of the
2214 mode hopping of the VCSels. However, in the past, some
2215 calibration runs have been taken (erroneously) with more
2216 than 5000 events, especially the intensity scans where
2217 a good precision is needed.
2218
2219 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2220 photo-electrons for the spline extractor by 1-2% (correctly).
2221
2222 - callisto: The intercalibration is now done using a full f-factor
2223 method instead of a simple update. This makes things slower but
2224 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2225 changes.
2226
2227 - callisto: MPedestalY3 now uses the same extraction range as the data
2228 as calculated by MPedestalY2
2229
2230 - callisto: A check of the fraction of allowed unsuitable (10%) and
2231 unreliable (30%) pixels has been addded when the conversion is
2232 calculated from interleaved events
2233
2234 - star: fixed a bug which caused MEffectiveOnTime containers not to
2235 be written. In the worst case they were skipped almost all, in the
2236 best case they were all ok. It depends on how often the new value
2237 was assigned just with an event which was skipped later by another
2238 task
2239
2240 - star: new histograms MHPointing and MHRate
2241
2242 - star: New tab (Currents) displaying the time evolution of the mean
2243 DC currents
2244
2245 - star: New tab (MeanRms) displaying the time volution of the mean
2246 Pedestal Rms
2247
2248 - star: Output now contains MReportStarguider
2249
2250 - star: Improved muon analysis. Due to the absense of a constant
2251 for the gaus fit for arc width and the fact that the arcwidth
2252 plot was a histogram instead of a profile the resulting psf
2253 became pedestal rms dependant
2254
2255 - ganymed: added new plot (MHPhi) for wobble mode as described in
2256 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2257
2258 - ganymed: corrects now (correctly?) for the misspointing in
2259 May/April 05
2260
2261 - ganymed: Two new default templates for ganymed.rc are avilable:
2262 ganymed_onoff.rc and ganymed_wobble.rc
2263
2264 - ganymed: The first version of MFMagicCuts has been released
2265
2266 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2267
2268 - ganymed, sponde: There are two new options to determin the number
2269 of bins for the signal region (NumBinsSignal) and the number of
2270 total bins (NumBinsTotal) in the MHThetaSq histogram
2271
2272 - ganymed: optimized palettes for MHDisp
2273
2274 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2275 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2276 sqrt(2) to large
2277
2278 - ganymed: The false source plot (MHDisp) is now based on Disp
2279 and a background model determined in the first loop is
2280 subtracted
2281
2282 - ganymed: MFMagicCuts are now available in the cvs. The correct
2283 solution for the disp ambiguity problem is now calculated using
2284 the third moment. The third moment cut therefor is skipped.
2285
2286 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2287 already determined by the third moment along the major axis and
2288 so its actual sign is aligned along the major axis of the shower.
2289
2290 - ganymed: If starguider data is available it is taken into account
2291 when calculating the source position. This is especially important
2292 for wobble data at high zenith angles and culmination data.
2293
2294 - ganymed: If available the starguider data is taken into account as
2295 good as it is possible without a starguider calibration. To switch
2296 it off add
2297 MPointingDevCalc.MaxAbsDev: -1
2298 to your ganymed.rc
2299
2300 - sponde: the zenith angle distribution is now weighted instead of
2301 choosen by default. This gurantees higher statistics in the highest
2302 and lowest energy bins. To switch this behaviour off use...
2303
2304 - sponde: now automatically displays the energy threshold
2305
2306
2307
2308 *** Version 0.9.3 (2005/06/03)
2309
2310 - general: MMcEvt now derived from MMcEvtBasic which should
2311 have no influence on compatibility with older camera files
2312
2313 - general: Implemented a new option to MReadReports which allows
2314 to force reading of the first event of some trees (eg. Drive-tree)
2315 before any other tree.
2316
2317 - general: Made a fix to MPointingPosCalc which assumes that the
2318 run-type is real-data if Process is called before ReInit, such
2319 that also the very first Drive-events in a run are treated
2320 correctly.
2321
2322 - shoplot now displays the filename in the title bar of the window
2323
2324 - merpp: new options: --auto-time-start --auto-time-stop which
2325 allow to cut updating with slow-control at the start- or
2326 (previousle --auto-time only allowed: and) stop-time of
2327 the run stored in the runheader.
2328
2329 - callisto: changed default of fgFallTimeHiGain in
2330 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2331 already set as default in callisto_Dec04Jan05.rc
2332
2333 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2334 now changes the filename for new weights automatically for
2335 cosmics, MC and for different calibration colors.
2336
2337 - callisto: a problem with the order of some code cause the
2338 name of the weights file in MPedestalY2 to be ignored.
2339 Wrongly the calibration_UV weights were used instead
2340 of the cosmics weights set in callisto.rc.
2341
2342 - callisto: should allow ct1 pulser data when the color is
2343 explicitly set also for pretty new runs
2344
2345 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2346 to introduce an additional scale factor (should be around 1)
2347 to adapt for slight deviations in different extractors from
2348 the MC calibration. For MC calibrations the scale factor
2349 is fixed to 1
2350
2351 - callisto: MFCosmics should handle very high signals a bit
2352 more accurate now
2353
2354 - callisto: when calculating the mean pedestal rms for different
2355 pixel sizes or sectors also kUnsuitableEvt is now taken into
2356 account - not only kUnsuitableRun
2357
2358 - callisto: '-raw' option is now the default
2359
2360 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2361 This has the advantage that mean values in the calibration (eg
2362 arrival times) are calculated more accuratly.
2363
2364 - callisto: In the resource file callisto_Dec04Jan05.rc
2365 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2366
2367 - callisto: new Hi-/Lo-Gain intercalibration constants
2368 hilocalib_sp1.root and hilocalib_sp1_mc.root
2369
2370 - callisto: changed default for MJPedestalY2.MaxEvents
2371 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2372
2373 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2374 has changed from 9.0 to 6.0. This is necessary to exclude two very
2375 ringing pixels in September which - when kept - destroy the image
2376 cleaning around them (Markus G.)
2377
2378 - callisto: (!) The Muon analysis of all data taken so far has
2379 suggested that different extractors give slightly different
2380 absolute results after calibration, due to there different
2381 handling of the calibration- and cosmics pulse shape. Although
2382 the over all calibration seems to be a bit to pesimistic (or
2383 the MC seems to be a little bit - 3-5% - too much attenuated).
2384 There for correction factors have been introduced which correct
2385 the calibration constants by
2386 0.956937799 for Digital Filter (callisto.rc)
2387 and
2388 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2389 calibration. The main advantage is, that both data types can
2390 be easily analysed together and compared to the same MC sample.
2391 The factors are choosen such, that the reference is now a
2392 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2393
2394 - star: fixed a bug which caused the first bin of the histograms
2395 vs time to disapear in PostProcess. This gave wrong results
2396 on the screen. The output and all following programs not
2397 directly accessing the histograms haven't been affected
2398
2399 - star, ganymed: Made sure that always the first Drive-tree event
2400 is read and Processed before the first data event was read.
2401
2402 - ganymed: implemented the possibility to replace the standard
2403 false source plot with a different one. For example: If
2404 you want to use a Disp based FS plot use the resource:
2405 NameHistFS: MHDisp
2406 For details about the requirements of these plots look
2407 at the corresponding classes
2408
2409 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2410 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2411 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2412 case MAlphaFitter is setup correctly. For On-Only optimization
2413 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2414 RunOn() instead of Run(). For energy estimation MJOptimize
2415 has been replaced by MJOptimizeEnergy
2416
2417 - sponde: The input MC spectrum can now be weighted to fake a
2418 different spectrum. This is done via MMcSpectrumWeight. For
2419 more details see the class description and sponde.rc
2420
2421 - sponde: The paremeter comparsion plots are not scaled by
2422 their entries anymore. Instead the MC plot is scaled by using
2423 the result spectrum of the analysis. If the input MC spectrum
2424 and the result spectrum has different slopes the absolut
2425 normalization is normally wrong.
2426
2427
2428
2429 *** Version 0.9.2 (2005/05/20)
2430
2431 - general: Changed the default paths for calibrated data and image
2432 files. (The implemented access to these files doesn't yet exist)
2433
2434 - general: support for MRunIter has been removed from the job classes
2435 (use the setter functions of MSeqeunce instead)
2436
2437 - general: ProcessFile has been renamed to Process in all job classes,
2438 because ProcessFile is missleading
2439
2440 - general: The storage of the palette in MHCamera is now possible
2441
2442 - general: new bits describing unsuitable and unreliable pixels have
2443 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2444 kDeadPedestalRms, kFluctuatingArrivalTimes
2445
2446 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2447 versions newer than V200404070
2448
2449 - general: support for cc file versions newer than V200504130. Added
2450 support for active loads (MCameraActiveLoad) and central pixel
2451 (MCameraCentralPixel)
2452
2453 - general: added new histograms for image parameters versus size
2454 (MHVsSize)
2455
2456 - general: The eventloop now automatically calls PrintStatistics
2457
2458 - Status Display: Improved support for printing:
2459 + A default can now be set in .rootrc (for more details see
2460 MStatusDisplay::PrintPS)
2461 + A print dialog is opened so that printer and command line
2462 can be canged
2463
2464 - showlog: improved such that it handles different verbosity levels
2465 more accurate now. This mean you can suppress output when
2466 using showlog.
2467
2468 - showplot: improved
2469 + The new graphics formats have been implemented
2470 (pdf, svg, png, jpg and xpm)
2471 + Implemented an interface for printing. Because you can change
2472 the printing command from the command line you can use all
2473 the nice postscript tool. To print a booklet for example call:
2474 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2475 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2476 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2477
2478 - callisto: fixed a bug in the recognition of the calibration bit
2479 pattern. Concerns only intensity calibration. (The strength of the
2480 intensity has been updated in some cases)
2481
2482 - callisto: add a filter against PIN Diode events when running over
2483 calibration runs since some of the recent calibration runs have
2484 been taken with Pin Diode.
2485
2486 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2487 39943, 44833 in the calibration (MCalibColorSet)
2488
2489 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2490 been set to 1e-18 in callisto_Dec04_Jan05.rc
2491
2492 - callisto: in callisto_Dec04Jan05.rc: set value for
2493 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2494 statistics for the calculation of the mean pulse time
2495 of the cosmisc
2496
2497 - callisto: the charge limit in the calibration has been raised
2498 from 2.5 to 4.5
2499
2500 - callisto: new setup read from callisto.rc
2501 + MCalibCalcFromPast.fNumEventsDump
2502 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2503 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2504
2505 - callisto: MExtractTimeAndChargeSpline extractor:
2506 + The integration ranges were shifted by 0.2 FADC slices to the right.
2507 + unreliable handling of floating point values caused different
2508 results on different platform or with different compiler options:
2509 The new algorithm is numerically exact and more accurate because
2510 it doesn't calculate the integration position by multiple times
2511 adding the step-size (which results in numerical uncertanties
2512 exspecially if multiplied with large numbers)
2513 + A lot of fixes have been introduced which effects integrating the
2514 spline at the edges of the valid range. In this case any memory
2515 was randomly accessed. This behaviour can be tested replacing
2516 all MArrayF by TArrayF which perform a range check (but of course
2517 they are a lot slower)
2518 ! No result obtained with the Spline before can be trusted! Due to
2519 random memory access it might by completely random!
2520
2521 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2522 + extraction range in the high gain to 4.
2523 + weights file to cosmics_weights46.dat
2524
2525 - callisto:
2526 + introduce the check for fluctuating arrival times.
2527 + set charge limit to from 2.5 to 4.5
2528 + introduce asymmetric exclusion due to "deviating number of phes":
2529 Default: -9.0 +4.5
2530 + make deviating number of phes unsuitable (see David's findings).
2531
2532 - callisto: fixed the display of unsuitable pixels. The old change
2533 to a real profile in MHCamera broke it.
2534
2535 - callisto: The cosmics filter is used in MJCalibration now
2536 independant of the pulser color (formaly it was used only for
2537 CT1-pulser data). The threshold of number of max empty pixels
2538 has been raised from 2% to 5% in MJCalibration. The maximum
2539 fraction of rejected event is 50% otherwise the calibration has
2540 failed. The filter now ignores unsuitable pixels.
2541 Setup the filter from callisto.rc using "ContCosmics"
2542 (see MFCosmics::ReadEnv)
2543
2544 - callisto: changed default for fgOffsetFromLogain back
2545 from -2.8 to -1.8 in digital filter.
2546
2547 - callisto: for the common extractors
2548 + MExtractFixedWindow
2549 * MExtractTimeAndChargeSlidingWindow
2550 * MExtractTimeAndChargeSpline
2551 * MExtractTimeAndChargeDigitalFilter
2552 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2553 and fResolutionPerPheLoGain
2554
2555 - callisto: Updated the hi-/lo-gain intercalibration constants
2556 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2557 hilocalib_df6.root
2558
2559 - callisto: The default lo-gain extraction window for the
2560 MExtractTimeAndChargeSlidingWindow extractor has been increased
2561 from 6 to 8 to take the stretch of the pusle into account
2562
2563 - callisto (!!!): fixed an important bug in the setting of the
2564 incoming pedestal pointer to the signal extractor extracting
2565 pedestals. This bug caused the pedestals not to be subtracted
2566 correctly in the calibration afterwards. The effect was about 10%
2567 too high conversion factors for the digital filter and the spline
2568 and more than 40% for the sliding window.
2569 The bug existed since end of February! (Markus G.)
2570
2571 - star: added muon support to star. A new tab "MHMuonPar" is
2572 displayed. The lower right plot is an estimate of the point spread
2573 function. A reference value is displayed. To get the real PSF
2574 you must compare with MC. The setup for the muon analysis
2575 is done in star.rc. More informations can be found in
2576 MHSingleMuon and MHCalibParCalc
2577
2578 - star: The weather data is now displayed in star
2579
2580 - star: MEventRateCalc handles the calculation of the event rate more
2581 accurate now in case of the start of a new run inside a sequence
2582
2583 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2584 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2585 changed only minimally
2586
2587 - ganymed: (MJCut and MJOptimize) now displayes the number of
2588 excess events versus size. The energy estimation is done in
2589 MJSpectrum (sponde)
2590
2591 - ganymed: got support for using other variables than Alpha, eg. Theta.
2592 Therefor you need a class deriving from MHAlpha which supports
2593 this variable (one is already existing: MHTheta, which is now the
2594 default in ganymed). It is setup through ganymed.rc
2595
2596 - added a full featured spectrum program (sponde) which reads
2597 ganymed output and monte carlos and compiles a spectrum
2598
2599
2600
2601 *** Version 0.9.1 (2005/04/14)
2602
2603 - Fix bug on the arrival time reconstruction when using Digital
2604 Filter (in some marginal cases (10%) times were reconstructed shifted
2605 by 0.2 slices)
2606
2607 - all executables now return 2 where in previous versions -1 has
2608 been returned (gave problems with shell-scripts)
2609
2610 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2611 also done with a intercalibration input file
2612
2613 - a bug in the time fine adjustment of the digital filter has been fixed
2614
2615 - a lot of small fixes to calling TPad::Divide with a margin==0
2616
2617 - MStatusDisplay now shows the memory usage
2618
2619 - added a memory leak statistic after the eventloop
2620
2621 - MHadronness replaced by MParameterD
2622
2623 - MEnergyEst replaced by MParameterD
2624
2625 - wobble mode can now be switched on from the data-set
2626
2627 - switched on bad pixel detection for a pedestal level
2628 which is more than 5 times the variance
2629
2630 - Fixed default paths to be correct for the new data center
2631
2632 - Fixed handling of drive data. The pointing position in now
2633 copied to MPointingPos inside star for real and MC events
2634
2635 - made sure, that the sequences in a dataset are sorted by
2636 their number to ensure the correct synchronization
2637
2638 - added all resource files necessary to handle spline extraction
2639 of signal for the late 2004 and the early 2005 data
2640
2641 - update the reference lines for the december data
2642
2643 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2644 This is important for the Dec. and Jan. data where the calibration
2645 pulse position changes much.
2646
2647 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2648 filter. This corrects only an defective extraction of the MC at
2649 low-gain signals lower than 90 phes.
2650
2651 - fixed some slowdown in calibrating data with interleaved events from
2652 Jan and Dec. As a workaround made the pretty palette the default.
2653 The inverse Deep Blue Sea has a bug which slows down long calibration
2654 runs a lot.
2655
2656 - implemented new values from new starguider report as defined
2657 in TDAS00-07 V7.1 (eg SkyBrighness)
2658
2659 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2660 in starguider report (If you merpp the same reports with this version
2661 you'll get the correct units (arcmin) but a different result
2662 than with old versions (wrong units))
2663
2664 - Now the status display can also write PNG, JPEG and XPM (other file
2665 formats are still unsupported by root)
2666
2667 - added a lot of scripts and macros in directory datacenter used
2668 for automatic processing
2669
2670
2671
2672 *** Version 0.9 (2005/03/23)
2673
2674 - Calibration is now done autmatically into photo-electrons like
2675 decided by the Collaboration Board
2676
2677 - Reference lines in the display can be read from resource file
2678
2679 - Interlaced calibration events can be handled by callisto
2680
2681 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2682 and applied in callisto.
2683
2684 - class MJCalibTest can be called by callisto
2685
2686 - callisto can now run with three data types: rawdata, rootdata, MC
2687
2688 - added two classes mreport/MReportStarguider.cc and
2689 mreport/MReportStarguider.h for implementing starguider-data
2690
2691 - the output of merpp-update now contains starguider information:
2692 MReportStarguider and MTimeStarguider
2693
2694 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2695 values were lower than they should. This was more visible for high
2696 energy (Size) events.
2697
2698 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2699
2700 - added a new loop to callisto to support the correct extraction of
2701 the pedestal and pedestal rms through the signal extractor
2702
2703 - added class to perform fourier tranformation of a hexagonal structure
2704 (MHexagonalFT)
2705
2706 - added class to perform fourier tranformation of a hexagonal structure
2707 in a tasklist (MHexagonalFTCalc) example: hft.C
2708
2709 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2710 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2711 small pixels, example: extendcam.C
2712
2713 - added possibility to write data to memory (TTree) using MWriteRootFile
2714
2715 - added possibility to read a TTree stored only in memory by MReadTree
2716
2717 - new classes to deal with the interleaved calibration events:
2718 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2719
2720 - implemented filters to callisto to skip calibration events
2721
2722 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2723 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2724 the slices by statistics
2725 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2726 signal extractor without randomization
2727 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2728 with the signal extractor with randomization (extraction window is
2729 randomly fixed)
2730 The three kind of pedestal is not yet implemented (for speed reasons) as
2731 long as nobody really needs it:
2732 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2733 extracted with the signal extractor with randomization
2734
2735 - callisto now finds the pulse position in the data automatically
2736
2737 - implemented data reduction in calibrated data by reducing the precision
2738 of the stored floating point values (pedestal, rms and signal) to
2739 roughly 0.5%
2740
2741 - fixed showplot to make file format conversion (eg. converting a
2742 status display stored in a root file into a postscript file) in
2743 batch mode possible:
2744 showplot -b --save-as-ps[=outfile.ps] infile.root
2745
2746 - Allow class names as part of filter rules, eg
2747 (MFSupercuts) && (MHillas.fSize>100)
2748
2749 - fixed a lot of stuff to allow all programs to process MonteCarlo
2750 camera files.
2751
2752 - enhanced possibility to debug reading of resource file
2753
2754 - MDataChain should handle priorities of operator more
2755 accurate now
2756
2757 - completely revised the container in which the signal is stored
2758 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2759 * the new implementation is faster and
2760 * needs less storage space
2761
2762 - FIRST version which can process Monte Carlos through the
2763 whole chain of programs (callisto, star, etc)
2764
2765 - implemented new image parameters for the border length of
2766 the shower image (MNewImagePar2)
2767
2768 - implemented wobble-mode in ganymed
2769
2770 - new class (MJOptimize) taking care of all optimization processes
2771
2772
2773
2774 *** Version 0.8.6 (2004/10/05)
2775
2776 - New combined signal and time extractor
2777 MExtractTimeAndChargeDigitalFilter
2778
2779 - The Report for the trigger section in the CC run summary has been
2780 updated, and now the IPRs (Individual Pixel Rates) are available.
2781
2782 - new macros for database interaction: filldotrun.C, filldotrbk.C
2783
2784 - added new program which can convert colored output which was redirected
2785 into a file back into colored text (for example to display it with
2786 more): showlog
2787
2788 - added new program to display an MStatusArray of plots (stored with
2789 MStatusDisplay) from a file: showplot
2790
2791 - Added support for Sequences (MSequence). Sequences are blocks of run
2792 files containing the same calibration and belonging to the same
2793 source
2794
2795 - Added a new task (MTaskEnv) which can be used in setup files to switch
2796 between different tasks (for example to choose a signal extractor)
2797
2798 - Implemented automatic file splitting in MWriteRootFile
2799
2800 - After image cleaning an island index is assigned to all used pixels.
2801 The index corresponds to the order of the islands in size.
2802
2803 - added a cleaning which takes signal height _and_ arrival time into
2804 account: probability cleaning (for more details see MImgCleanStd)
2805
2806 - added a cleaning which takes takes the absolute number of photons
2807 times the area ratio as cleaning level
2808 (for more details see MImgCleanStd)
2809
2810 - Changed calculation of image parameters such, that it can be done
2811 for all used pixels or the pixels with a defined island index only
2812
2813 - implemented new image parameters displaying the number of islands,
2814 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2815
2816 - event display in executable changed to support also calibrated files
2817 (done with MJCalibrateSignal)
2818
2819 - added program doing the calibration and the signal extraction
2820 and signal calibration: callisto Most part of the setup is done
2821 by a resource file: callisto.rc
2822
2823 - implemented support for pixels with negative IDs (Raw file format
2824 version 4)
2825
2826 - implemented an new option in merpp (--auto-time) to get the time
2827 range for cc and/or caco data from the run header of the raw data
2828
2829 - New star-program (star and MJStar). Taking calibrated data from
2830 callisto/MJCalibrateSignal as input. The setup is done through
2831 a resource file: star.rc
2832
2833 - Added possibility to setup the eventloop in the mars-executable
2834 Camera Display by a resource file: mars.rc
2835
2836 - The the mars-executable Camera Display can now also read
2837 calibrated data files written by callisto/MJCalibrateSignal
2838
2839 - Added a new class which can calculate the source position in
2840 the camera from a pointing model known to be correct and
2841 the pointing model used for observations (MSrcPosFromModel)
2842
2843 - added a new version of the class calculating the effective on-time
2844 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2845 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2846 MHTimeDiffTheta.
2847
2848 - added the possibility to count how often a signal is above (or
2849 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2850 can replace MHTriggerLvl0)
2851
2852 - added ore convinient ways to set the axis-titles of your histograms
2853 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2854 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2855
2856
2857
2858 *** Version 0.8.5 (2004/08/06)
2859
2860 - new Signal Extractors: MExtractFixedWindowSpline
2861 and MExtractAmplitudeSpline
2862
2863 - implementes interleave in merpp to be able to merpp parts of a file
2864
2865 - implemented force-functionality to merpp
2866
2867 - star display to display star catalogs (MAstroCatalog)
2868
2869 - star display to 'mirror' stars to the camera (MAstroCamera)
2870
2871 - implemented a new cleaning option which allows cleaning scaled with
2872 the real ratio of the rms depending on the pixel size, not only the
2873 square root of the pixelsize (MImgCleanStd, MCameraData)
2874
2875 - removed obsolete MBlind* classes
2876
2877 - Signal extractor taking the AB flag into account implemented (this makes
2878 an odd number of slices for signal extraction possible
2879 (MExtractSignalABcorr)
2880
2881 - implemented a class extracting the pedestal from the raw-data (events)
2882 itself using empty lo-gain (MpedCalcFromLoGain)
2883
2884 - Added mean values to MPedPhotCam
2885
2886 - Added Makefile for Darwin (this OS is NOT officially supported!)
2887
2888
2889
2890 *** Version 0.8.4 (2004/04/19)
2891
2892 - new fast arrival time extractor using cubic splines:
2893 MExtractTimeFastSpline
2894
2895 - implementes multi-argument support in MDataChain
2896 ("pow(a, b)")
2897
2898 - implemented double reference support in MDataChain
2899 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2900
2901 - added support in MF for expressiond like
2902 "MHillas.fWidth<2*<MHillas.fLength"
2903
2904 - MDataChain is now able to support variables like [0], [1], ...
2905 which can be used in fit functions as parameters. The interface
2906 is implemented through the new virtual function
2907 MParContainer::SetVariables
2908
2909 - added new class MArrivalTimeCam/MArrivalTimePix:
2910 Storage containers to hold the ArrivalTime of the camera/pixel
2911
2912 - added new classes for the calibration of relative arrival times:
2913 MCalibrationRelTimePix and MCalibrationRelTimeCam
2914
2915 - added new classes to extract the signal of the blind pixel and the
2916 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2917
2918 - added new classes for the bad-pixels treatment (MBadPixels*)
2919 which are more powerfull than the old ones (MBlindPixel*)
2920 and will replace them.
2921
2922 - added filter against cosmics: MFCosmics
2923
2924 - added new class MArrivalTimeCalc2:
2925 Calculates the arrival time as the signal weighted mean of the time
2926 slices in the maximum window
2927
2928 - added a new macro call pointspreadfucntion.C that fits with a 2D
2929 gaussian the DC spot for an star. It gives you the RMS of
2930 the PSF and the center of the star, very useful for misspointing
2931 studies.
2932
2933 - added support for multi-telescope camera files. Added classes
2934 MStereoCalc and MStereoPar, classes to calculate and store shower
2935 parameters calculated from the data of two telescopes, for the MC
2936 studies regarding the MAGIC clone.
2937
2938 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2939 MC data calibrated in photons instead of ADC counts.
2940
2941 - added three macros to show the calibration and analysis chain of
2942 MC data. The macro starmc.C does both calibration and analysis, producing
2943 an output containing Hillas parameters for each event. The macro
2944 mccalibrate.C does just the calibration and writes out a file containing
2945 pixel information in photons instead of FADC data. The macro starmc2.C
2946 reads in such a file and produces an output with Hillas parameters.
2947
2948 - added MPedPhotCalc to compute pedestals in units of photons, see
2949 macro pedphotcalc.C
2950
2951 - added all class to perform the calibration, see macro calibration.C
2952
2953 - added class MFFT to perform Fast Fourier Transforms
2954
2955 - added class MSimulatedAnnealing to perform simulated annealing
2956 minimizations
2957
2958 - added new macro bootcampstandardanalysis.C which holds the skeleton
2959 of the analysis chain discussed in the december bootcamp.
2960
2961 - added support for DAQ raw data file format V2
2962
2963 - implemented an arbitrary time stamp for the events from raw-data
2964 files with file version<3. It is calculated from the run number,
2965 the date of start and the FADC clock tick from the first module
2966
2967 - implemented the correct decoding of the event time-stamp
2968 coming from the DAQ for raw-data files with file-version>2
2969
2970 - added a new classes storing the pedestals in units of photons:
2971 MPedPhotPix, MPedPhotCam
2972
2973 - added support for DC current files from the camera control
2974
2975 - added support for start- and stop-time when merpping report files
2976
2977 - added MReportCC storing the weather data from the CC-REPORT
2978
2979 - added class to fill trainings and test matrices (MTFillMatrix)
2980
2981 - added a filter performing a software trigger (MFSoftwareTrigger)
2982
2983 - Added classes to perform parts of the standard analysis (Jobs):
2984 + MJPedestals
2985 + MJCalibration
2986 + MJExtractSignal
2987 Note: All of them are preliminary!
2988
2989 - Added Iterator to iterate over files giving only the run-number
2990
2991 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2992 the evolution of a sector vs time
2993
2994
2995
2996 *** Version 0.8.3 (2003/12/05)
2997
2998 - adapted Random Forest classes to allow the use with MC
2999 multi-telescope files which can be produced with the coming
3000 camera version 0.7.
3001
3002 - added classes to read and interprete central control report files
3003 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
3004
3005 - enhanced merpp (the executable) to support .raw and .rep files.
3006
3007 - added classes for light calibration (MCalibration* and
3008 MHCalibration*) by Markus Gaug. Further work has to be and will
3009 be done soon.
3010
3011 - Added a preliminary 'synchronizer' (MReadReports) which will
3012 replace MReadMarsFile as soon as it is finished.
3013
3014 - Added a tutorial macro demonstrating how report files are merpped
3015 and how they can be read from the root file in the correct order
3016 of time (readrep.C)
3017
3018 - Added a generalized histogram (similar to MH3) called MVsTime
3019 which allows to plot variables (or rules - MDataChain - of
3020 variables) vs time. For an example have a look at tempvstime.C.
3021
3022 - Changed the name of the event trees:
3023 + Events --> Events
3024 + PedEvents --> Pedestals
3025 + CalEvents --> Calibration
3026
3027 - changed name of MTime in the event trees from MRawEvtTime to MTime
3028
3029 - added displaying the sector indices to the mars event display
3030
3031 - Magic Online Analysis (MOnA) implemented in a first version
3032 (see mona.cc, MOnlineDump and MOnlineDisplay)
3033
3034 - added classes to calculate event rate
3035 (preliminary: MEventRateCalc, MEventRate)
3036
3037 - added new executable 'readdaq' to read *.raw files from the DAQ directly
3038
3039 - added classes dealing with the telescope pointing position (MPointing*)
3040
3041 - implemented the 'final' Mars time stamp based on some experiences with
3042 the new 'Synchonizer'
3043
3044
3045
3046 *** Version 0.8.2 (2003/11/10)
3047
3048 - accelerated standard analysis by a factor of 6-8 ...
3049 + doing precalculations in MGeomCam for the pixel area ratio
3050 + creating a look up table for the single pixels in MCerPhotEvt
3051
3052 - added task to calculates weights in case you want to 'change'
3053 the energy spectrum of a monte carlo file
3054 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
3055
3056 - added a new executable star which implements the
3057 star.C macro as precompiled executable. Currently a flexible
3058 setup is not possible, but a 'input card' setup will follow.
3059
3060 - Starting to implement Multi-Telescope-Support based on the
3061 upcomming camera version 0.7. The base for a general support
3062 is implemented and the star-functionality is proven to work.
3063
3064 - Replaced Event-Display in and Camera-Display in the Mars GUI
3065 executable by a more convinient display base on MStatusDisplay.
3066
3067 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
3068
3069
3070
3071 *** Version 0.8.1 (2003/10/20)
3072
3073 - added signal subtraction for pure on data by means of fitting
3074 the background in the off region or by performing a combined
3075 signal/background fit. Provides necessary histograms for
3076 obtaining energy spectra and a light curve.
3077
3078 - added classes to perform and study the selection of the
3079 2nd Level Trigger on MC data (example in triglvl2.C macro)
3080
3081 - added pedestal calculation
3082
3083 - implemented "democratic cleaning" (tail cut value proportional
3084 to pixel area) according to Wolfgang's suggestion.
3085
3086 - added Sigmabar treatment (calculation and basic histogramming)
3087
3088 - added basic routines to apply padding
3089
3090 - added first implementation of MARS-based source visibility plotter
3091 (needs to be linked against slalib, preliminary version)
3092
3093 - enhanced functionality of data chains: random numbers, conversion
3094 functions and access to MHMatrix objects
3095
3096 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
3097 numbers under certain circumstances (runs with 0 events included)
3098
3099 - fixed a bug in the general filter MF (didn't work on some systems
3100 at all)
3101
3102 - fixed a bug in chaining files, which caused the analysis to crash or
3103 ignore files
3104
3105 - implemented more geometry classes describing the parameters used
3106 to simulate the PMT camera
3107
3108 - added new Monte Carlo classes containing the setup of the different
3109 programs in the MC chain.
3110
3111 - added a (preliminary) general task to evaluate chi-square of a given
3112 parameter in an eventloop.
3113
3114 - first implementation of a container describing the observatory
3115 location (Long, Lat, etc)
3116
3117 - added Random Forest - method for g/h-separation
3118
3119 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3120 (this means, that it is compiling, but not yet fully tested)
3121
3122 - added a new status display which can show the present status
3123 of histograms while an eventloop is running (MStatusDisplay,
3124 an example can be found at status.C)
3125
3126 - reorganized directories:
3127 classes describing the image --> mimage
3128 classes containing Monte Carlo Histograms --> mhistmc
3129 classes for Random Forest method --> mranforest
3130
3131 - added (event-)weights to fill histograms
3132
3133 - colors in logging output to screen
3134
3135 - changes to the Image Parameter declaration:
3136 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3137 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3138 + MHillasExt now derives from MParContainer instead of MHillas
3139 --> Files written with the old definition are more or less unreadable
3140
3141 - reading of reflector files
3142
3143 - display data from reflector files in the camera
3144
3145 - implemented currents (and display them in the camera)
3146
3147 - logarithmic scale in camera
3148
3149 - added class to iterate through directory contents (MDirIter)
3150
3151
3152
3153 *** Version 0.8 (2002/11/18)
3154
3155 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3156
3157 - corrected 48(!) wrong entries in the Next Neighbor table of the
3158 Magic Camera (all in the inner part of the outer ring, mostly
3159 missing a single NN)
3160
3161 - Fixed a bug in the table describing the Next Neighbours of the
3162 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3163 have any neighbour)
3164
3165 - changed trigrate.C: now it calculates the pure NSB triggers from
3166 a camera file (generated with no showers), so there is no need
3167 to introduce them by hand in the BgR array (for more details
3168 please ask Abelardo)
3169
3170 - added MHHadronness (and MHadronness) as a general facility to evaluate
3171 the quality of a gamma-hadron seperation method
3172
3173 - changed MWriteAsciiFile to accept rules (MDataChain)
3174
3175 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3176 must be replaced by calles to MWriteAsciiFile::AddColumn and
3177 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3178 changed.
3179
3180 - Implemented generalized event-matrices (one row per event)
3181 (MHMatrix)
3182
3183 - implemented the one dimensional composite probabilities
3184 (MHCompProb, MCompProbCalc, comprob.C)
3185
3186 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3187 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3188
3189 - Added a camera display displaying the pixel numbers to the
3190 event display gui.
3191
3192 - Added Monte Carlo Informations to event display gui
3193
3194 - Changed the camera display to display the pixel numbering
3195
3196 - Added three buttons to the camera display to change the palette
3197
3198 - Added the number of used and core pixels after image cleaning
3199 to MHillas
3200
3201 - Changed the algorithm used in MHillas according to TDAS 02-03
3202
3203 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3204
3205 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3206
3207 - Added fCosDeltaAlpha to MHillasSrc
3208
3209 - The numbers of photons used to calculate fConc and fConc1 in
3210 MHillasExt are now scaled with the pixel size, so that one get
3211 a four times smaller value for the bigger pixels in the outer ring.
3212
3213 - added new task to smooth the camera contents (MCameraSmooth)
3214
3215 - added possibility to use interpolated pixel values for blind pixels
3216 instead of removing it completely from the analysis
3217
3218 - Implemented the possibility to save the whole eventloop with
3219 its setup to a file. This information can be read and from
3220 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3221 and MEvtLoop::MakeMacro. If you find something not working, please
3222 report - this stuff is still in a beta phase.
3223
3224 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3225 file having crab starfield, but also for all following files - fixed
3226
3227 - MTaskList::PrintStatistics can now be instructud to print also the
3228 title, too: use PrintStatistics(0, kTRUE)
3229
3230 - Changed the image cleaning so that pixels with to many 'used'
3231 neighbors are left used (to get rid of 'holes' in events)
3232
3233 - Introduced more output to the camera displays
3234
3235 - Added an array of histograms (eg one hist per run), MHArray
3236
3237 - Added a _preliminary_ version of the reader for CT1 PreProc files
3238 (MCT1ReadPreProc)
3239
3240 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3241 (thanks to Raquel)
3242
3243 - added the first energy estimator (MEnergyEstParam, estimate.C,
3244 estfit.C) using a parametrization
3245
3246 - Added some new Monte Carlo paremeter containers used to store
3247 setup information from the MC chain (MMcConfigRunHeader,
3248 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3249
3250
3251
3252 *** Version 0.7 (2002/04/30)
3253
3254 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3255 the pedestal mean value was saved incorrectly. For files from
3256 this versions we substract 0.5 from the pedestal mean.
3257 WARNING: This may effect your results, so don't wonder...
3258
3259 - First implementation of an algorithm using only triggered events
3260 for the collection area calculation
3261
3262 - Ascii Output can now also be used for parameter containers which
3263 doesn't overload MParCointainer::AsciiWrite
3264
3265 - The Ascii Output is now also capable of writing single data members
3266 of one container
3267
3268 - You are now able to change the order of the values written to the
3269 ascii file
3270
3271 - You can now specify a conversion factor for each data member written
3272 to an ascii file. This may be usefull to change the units of the
3273 data member (eg. degrees instead of millimeters in case of the
3274 hillas parameters)
3275
3276 - Replaced old MHillas by a new structure which allows you to extend
3277 the parameters stored in MHillas very easily:
3278 see MHillas and MHillasExt
3279
3280 - Added classes to handle source dependancy of image parameters:
3281 see MHillasSrc
3282
3283 - Added container (MBinning) to have a standard input for the binning
3284 in different histograms (eg. the Energy bins should be the same in
3285 all histograms)
3286
3287 - Changed Hillas histograms from mm to deg
3288
3289 - Added the flexible binning to the hillas histograms
3290
3291 - Added a filter for the alpha parameter (MFAlpha)
3292
3293 - It is now possible to write single data members of a class object to
3294 an output stream instead of the whole container only
3295
3296 - Added a generalized filter for a data member:
3297 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3298
3299 - Added a generalized Filter parser for more difficult filter rules
3300 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3301
3302 - Added new Monte Carlo histograms:
3303 MHMcEnergyImpact and MHMcEfficiency
3304
3305 - Added many new histograms needed for the flux calculation.
3306
3307 - Added a generalized histograms which can fill and show up to three
3308 data members in either a one-, two- or three-dimensional histogram, eg:
3309 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3310
3311 - Added:
3312 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3313 * calculation of <Theta> as a function of time (MHThetabarTime)
3314 they are needed in the flux calculation in
3315 order to select for a given bin in Theta (or time) the appropriate
3316 effective collection area, which is assumed to be given as a function
3317 of Theta and the true energy
3318
3319 - Added calculation of the migration matrix in the energy
3320 (MHMcEnergyMigration):
3321 the migration matrix describes the migration from the true (E_true)
3322 to the estimated energy (E_est); it is needed to determine the
3323 distribution of E_true from the measured distribution of E_est
3324 by unfolding
3325
3326 - changed the color palette in the camera display to DeapSea.
3327
3328
3329
3330 *** Version 0.6 (2002/01/15)
3331
3332 - Introduce the option of disable pixels (MBlindPixels and
3333 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3334 able to deal with Star Field NSB.
3335
3336 - Fixed a bug in the pedestals substraction
3337
3338 - Introduced verbosity levels
3339
3340 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3341
3342 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3343 work correctly (thanks to Abelardo)
3344
3345 - Introduced correct treatment of the diffuse Night Sky Background
3346 and NSB (MMcPedestalNSB)
3347
3348 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3349
3350 - Introduced MMcRunHeaders which contains monte carlo run informations
3351
3352 - Added a 'Print'-Task (MPrint) which calls the Print function
3353 of a parameter container for each event
3354
3355 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3356
3357 - changes to be more efficient with root 3.02/06
3358
3359 - root 3.02/06 fixes:
3360 + the memory leak when reading MRawEvtData
3361 + loosing more time than necessary to update the progress bar
3362
3363 - MWriteAsciiFile is now capable of writing more than one container
3364 in a line. For example: To be able to write Monte Carlo and
3365 Hillas values (energy and alpha) in one line.
3366
3367
3368
3369 *** Version 0.5 (2001/11/06)
3370
3371 - Added new GUI functionality (Analysis)
3372
3373 - Added a camera display to be able to display events in the camera
3374 together with the calculated hillas ellipse
3375
3376 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3377 object at any state of the analysis, so that the output are several
3378 states
3379
3380 - Fixed a bug in the collection area error calculation
3381 (Thanks to Ciro and Abelardo)
3382
3383 - Fixed a bug which causes merpp to crash in some environments
3384
3385 - Implemented auto enabling scheme for Branches to speed up reading
3386 a lot (see MReadTree and MTask)
3387
3388 - Fixed a bug in the Histogram classes which caused histograms to
3389 be written to a file by MWriteRootFile without request
3390
3391 - changed the object I/O from the old stylish root I/O to the new
3392 'auto evolution scheme' This was done only for classes which are not
3393 yet used in Monte Carlo files, so that these files are still readable.
3394
3395 - Added support for a progress bar in MEvtLoop and MReadTree
3396 (see the Analysis Window in Mars for an example)
3397
3398 - Fixed a bug in the package creation which disturbed the conversion
3399 between a mars version unpacked from a tar file and the repository.
3400
3401 - Changed the code to writer merpped (converted into root format)
3402 raw files, to get faster (around 10%)
3403
3404
3405
3406 *** Version 0.4 (2001/09/20)
3407
3408 - This release is made to compile on a root version >= 3.00
3409
3410 - Fixed a bug which causes MReadTree to read the first file only
3411
3412 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3413
3414 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3415
3416 - Added a task to write several container to a root file (MWriteRootFile)
3417
3418 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3419
3420 - Added calculation of the collection area (MMcCollectionAreaCalc)
3421
3422 - fixed some bugs in the Hillas calculation
3423
3424 - added filters to be able to control the task execution dependent on
3425 a parameter (for example: the number of level 1 triggers in a MC-file)
3426
3427
3428
3429 *** Version 0.3 (2001/04/23)
3430
3431 - Many demo macros added
3432
3433 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3434
3435 - Hillas Calculation added
3436
3437 - Standard image cleaning available
3438
3439 - MReadTree is now able to handle more than one file
3440 (Remark: of the same structure)
3441
3442 - Now we are able to display events in a first version of the
3443 Camera event display. To do this we must run the macro
3444 "macros/readCT1.C" to read data from CT1.
3445
3446
3447
3448 *** Version 0.2 (2001/01/24)
3449
3450 - First Implementation of a Gui to read the raw data. Start the
3451 gui with the command mars.
3452
3453
3454
3455 *** Version 0.1 (2000/12/20)
3456
3457 - First official release 0.1
3458
3459 - Changes:
3460
3461 + changed calling style of MRawPixelIterator from do...while to
3462 while-loop