source: trunk/Mars/NEWS@ 9846

Last change on this file since 9846 was 9846, checked in by tbretz, 15 years ago
Added new class MJTrainImpact to estimate the impact parameter by use of a random forest.
File size: 139.4 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * On some systems (version of make?) the __LINUX__ definition was not set
8 when compiling. This lead to MTime(-1) not working properly. Fixed.
9
10 * The status display is now able to write a plain root file which means
11 that the MStatusArray container is omitted and the TCanvas are written
12 to the file directly. This allows to write files which are accessible
13 from a plain root (without MARS) if no MARS objects are contained
14 in the TCanvas'. In turn the reading of files which contains
15 objects and TCanvas' but no MStatusArray object has been improved.
16
17 * MMcEvt.fPhi and MMcEvt.fTheta have been moved to its base class
18 MMcEvtBasic. Consequently, the direction of the primary shower
19 is not lost in the OriginalMC tree anymore
20
21 * Added a new class MJTrainImpact to estimate the impact parameter by use
22 of a random forest
23
24 ;ceres:
25
26 * Allow for individual mirrors with parabolic shape (for details see
27 MReflector::ReadFile)
28
29 * As an additional output artificial star-files are written. They
30 contain star output compatible output based on the signal as
31 in the artificial callisto output files.
32
33 * The trigger channel which issued the trigger is now stored in
34 MRawEvtHeader::fNumTriggerLvl1
35
36 * The number of photons in the calibration signal is now distributed
37 by a possonian instead of a Gauss.
38
39 * implemented new file-naming scheme (corsika run-number is new
40 tranfered to the ceres output as file-number). Therefore a new option
41 has been implemented to set an artificial run-number:
42 ---run-number=12345
43
44 * The baseline, the baseline noise and the gain (multiplicator to the
45 pulse) are now accessible from the outside. The new values are:
46 MSimCamera.DefaultOffset
47 MSimCamera.DefaultNoise
48 MSimCamera.DefaultGain
49
50 ;star:
51
52 * The time constraint in the image cleaning is now scaled with the
53 pixel distance. Consequently, the value given is not absolute in
54 ns anymore, but in ns/deg. This means that the values for MAGIC
55 have to be scaled by a factor of 10.
56
57 * Star now calculates new timing parameters, namely:
58
59 ** MHillasExt.fTimeSpread:
60 This is the time spread (rms) around the mean of the arrival times.
61 It is calulated as
62 <math>\sqrt{\sum{t_i}/n}</math>
63 ** MHillasExt.fTimeSpreadWeighted:
64 This is the weighted time spread (rms) around the weighted mean of the arrival times.
65 It is calulated as
66 <math>\frac{1}{\sum{n_i}}\sqrt{\sum{n_i^2(t_i-<wt>)^2}}}</math>
67 or
68 <math>\frac{1}{\sum{n_i}}\sqrt{\sum{n_i^2t_i^2}+<wt>^2\sum{n_i^2}-2<wt>\sum{t_in_i^2}}</math>
69
70 ;trainenergy.C:
71
72 * The rsolution is not displayed anymore as resolution squared
73
74
75
76== Version 2.4 (2009/12/23) ==
77
78 ;general:
79
80 * Added a new palette "temp" to MH::SetPalette which should resample
81 a temperature
82
83 * Added consistency check for two consecutive runs
84
85 * Since ~1006246 (preliminary) the L1 signal (which is L1 after L2)
86 has been disconnected and the L1 (L1TPU) has directly been connected
87 to another bit in the trigger pattern. This has been fixed by an
88 update of the decoding. Both bits are now or'ed together.
89
90 * Added a new camera layout MGeomCamFact which is the "four rectangular
91 pixels ordered in a hexagonal geometry" layout
92
93 * All programs now store the command line as TNamed "CommandLine"
94
95 * the environment variable OSTYPE should now be obsolete. Instead
96 the output of "uname -s" converted to lower cases is used
97
98 * The Makefiles should now detect the OSTYPE automatically using
99 uname. This should make the setting of OSTYPE obsolete
100
101 ;showplot:
102
103 * If a file without a MStatusArray is opened all object (not just
104 canvases) found in the file are drawn. Note that this may result
105 in empty tabs.
106
107 ;ceres:
108
109 * The night sky noise is now scaled with the sensitive area and
110 is given in units per square centimeter
111
112 * The night-sky noise now also takes the cones transmission
113 into account
114
115 * The night sky noise can now be calculated from a night-sky
116 spctrum
117
118 * A transmission curve for the cones can now be given
119
120 * Added the possibility to add a cut after the image parameter
121 calculation (''Cut'')
122
123 * updated the PDE of the GAPDs with a more reliable curve from
124 the meeting page (linear extrapolate below 350nm)
125
126 * The impact distribution in the event distrbutions is now
127 perpendicular to Alt/Az and the histogram is displayed in 1D
128
129 * The GAPD PDE has been updated
130
131 * PDEs and mirror reflectivities have been linearily extrapolated
132 to match the wavelegth range between 290nm and 900nm
133
134 * There is no default pulse shape anymoe it must be given in
135 the resource file
136
137 * Fixed a bug which caused the aerosol coefficient to be incorrectly
138 initialized. The effect might be random but seems to be small.
139
140 * Now accepts sequence files as input
141
142 * creation of pedestal and calibration files is now steered by
143 --mode (see ceres help)
144
145 * Instead of initializing the whole G-APD chip (all cells) before
146 each event (which is rather time consuming) a time evolution before
147 each event is now simulated which is enough to recovere every cell
148 to 99.999% of its response taking the background rate into account.
149 This is in total about a factor of ten faster and should not be
150 less accurate because under normal conditions the recovering cells
151 and the newly hitten cells will hardly be identical (due to
152 statistical reasons)
153
154 * improved the trigger algorithm which is now faster and allows easily
155 for multiplicity triggers
156
157 * The PDC flag in the file name is now correctly written
158
159 * A "PreCut" has been added which can be used after reading the events
160 to select them even before any calculation is done.
161
162 ;merpp:
163
164 * The new drive reports which contain also the status of the starguider
165 are now implemented, but the starting date (17/05/09) is preliminary.
166
167 ;callisto:
168
169 * Fixed a bug which prevented MAGIC Monte Carlo file from being
170 calibrated (ceres files worked)
171
172 * updated (Muon) calibration constants of period 62, 63, 72-75
173
174 ;star:
175
176 * allow to run thru even if discriminator threshold are missing
177 (they are not used for analysis so far anyway)
178
179 ;ganymed:
180
181 * added new starguider calibration for sequences since 1000534
182
183 ;database:
184
185 * added possiblity to query/plot data from certain source (with
186 regular expressions) in plotdb.php
187
188 * new feature in showplots*.php: on mouse-over additional information
189 on the sequence is displayed
190
191 * tables on database website have also 'Last' link now
192
193 * new version of builddatasets.php with more comfortable sequence
194 selection
195
196 * new features in builddatasets.php:
197 - user management
198 - 'Get Data Set File' button
199 - 'Display Selected Sequences' button
200 - 'Display Not Selected Sequences' button
201 - 'Select all' buttons
202
203 * builddatasets.php: added possibility to update data sets in the
204 database
205
206 * added limit for cloudiness for sequences in the tab 'Limits'
207
208 ;automation:
209
210 * jobmanager can be used more flexible now: via environnent variable
211 $AUTOMATIONSETUP more than one jobmanager per user can be started
212 using the same MARS version
213 Usage: export AUTOMATIONSETUP=mysetup ; /fullpath/jobmanager
214 and provide a file Mars/datacenter/scripts/setup.mysetup
215
216
217
218== Version 2.3 (2009/03/07) ==
219
220 ;SUGGESTION
221
222 * There is no need to re-run any data because no change took place which
223 could have an effect on the output. However, if you want a
224 meaningful SrcPos plot for your MCs in sponde you must re-process
225 star for your MCs first.
226
227 ;REMARK
228
229 * File produced with this release containing a camera geometry (which
230 are basically all files were produced as default) will not be readable
231 by older releases.
232
233 ;general
234
235 * fixed a few small bugs which could cause the display to crash in ganymed
236 and sponde
237
238 * in sequence file the date can now be omittet. In this case the
239 leading date with the underscore is missing in the expected filename
240
241 * the geometry class now also supports other geometries than just hexagons
242
243 ;automation
244
245 * added magnetic field Azimuth direction (ARRANG), currently
246 at ~ -7deg at La Palma
247
248 ;database
249
250 * plotdb.php: added default (sequences) for startup, added possibility
251 to set size of plot
252
253 * added a new table ''RunDataCheck'' which containes the rates after
254 image cleaning for every run which succeeded star. It can be
255 plotted using ''plotrundb.C''
256
257 ;merpp
258
259 * added support for Arehucas Version >= 200812140
260
261 * added support for Arehucas Version >= 200809030
262
263 ;mars
264
265 * The display now also displays the trigger pattern
266
267 * The display can now display ceres reflector (_R_) files
268
269 ;ceres
270
271 * added a uniformly distributed one-bin time jitter for the start of the
272 digitization. Otherwise the first photon would be digitized always with
273 the same alignment to the bins
274
275 * Added a plot showing the production height of the photons
276
277 * Moved the particle id from the event header to the run header
278
279 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
280
281 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
282
283 * Added many new options to control the tasks. For deatils see ''ceres.rc''
284
285 * Removed obsolete plots in pedestal and calibration mode
286
287 * Removed the non-NightSky photons from the plots where they are just
288 disturbing
289
290 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
291
292 * The daq event number now represents the readout number
293
294 * The camera ''electronics'' can now be ''switched off''
295
296 * A new tab ''Info'' now display basic things like the reflector
297 layout
298
299 * Improved reading speed for corsika files
300
301 * Improved memory handling (if a large ampount of memory was needed
302 for a single event all further events were stored in the same
303 memory and it was never freed, so the program took this memory
304 until the end)
305
306 * Converted the code from MMCS' reflector program to MSimAtmosphere
307 (instead of the tables build in for MAGIC Winter and Summer
308 atmosphere we use the values written by Corsika fitted to the
309 tabulated atmosphere given as input)
310
311 * For caluclating the displayed image parameters in ceres a basic
312 image cleaning removing isolated pixels is now done.
313
314 * The magnetic field direction (ARRANG) is now taken into account
315
316 * Added plot for the energy threshold after trigger ''Threshold''
317
318 * Added plot for the effective collection area after trigger ''TrigArea''
319
320 ;star
321
322 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
323
324 * The definition of fConcCore has slightly changed. The numbers
325 might decrease a little bit (the effect should be rather small)
326
327 ;ganymed
328
329 * added pointing model 328198
330
331 ;sponde
332
333 * The SrcPos plot for your MCs was so far meaningless because it just
334 displayes the MSrcPosCam data from the input star-files. Unfortunately,
335 this containes was never written to the star-files yet.
336
337 * A new Tab 'OnTime' is available which is an effective on-time
338 fit as in star but for all data. This is mainly for manual cross-check
339 of the effective on-time
340
341 * In some circumstances it might be necessary to re-calculate the
342 eff. on-time from the fit in the new tab, e.g. when a zenith distance
343 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
344
345 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
346 it to its own output file (for convinience)
347
348
349
350== Version 2.2 (2009/01/30) ==
351
352 ;SUGGESTION
353
354 * This release doesn't contain a major change which is expected to
355 change your results. Nevertheless there are small changes to
356 the calibration which can effect at least the first few hundred
357 events in any (mainly MUX and even more SUM) sequence a little bit.
358 So it is recommended although not necessary to reset your sequences
359 in the database before further processing.
360
361 ;NEW
362
363 * A first implementation of a Monte Carlo simulation program
364 (ceres - Camera Electronics and REflector Simulation) has been
365 implemented. It can simulate a full telescope already including
366 a complete reflector simulation and a flexible trigger and readout
367 simulation. Currently, no perfect setup is implemented and
368 especially the output of the program (data structure) should
369 be considered alpha state. Also the user interface is not yet
370 ready.
371
372 ;general
373
374 * All command line options after -- are now interpreted as
375 arguments (usually everything which doesn't start with a minus)
376 rather than options (usually everything which starts with a
377 minus). This allows to use file names starting with a -
378
379 * In all resource files you can now initialize the random number
380 generator. For details see: MJob::InitRandomNumberGenerator
381
382 * added a new program called ''readcorsika''. It's purpose is (in analogy
383 to readraw and readdaq) to read a Corsika output file (for now
384 only cherenkov output is supported) and print its contents in a
385 human readable form. It can also write the contents of this file
386 into a root-file.
387
388 * The calculation of the maximum distance to the origin in a MGeomCam
389 has been improved (edges might be further away than the sides).
390 This is just a tiny change but it might change the appearance of
391 the radial profiles a little bit.
392
393 * The default binning of the center-of-gravity plot has slightly been
394 increased
395
396 ;Database
397
398 * Added informations about the DC currents (fMinCurrents, fMedCurrents
399 and fMaxCurrents). The values are retrieved from the plots showing
400 the average DC currents of all pixels versus time.
401
402 * Websites with tables have now the opportunity to remove lines
403 ('-' button at beginning of each line) and get all lines back
404 ('+' at top of the column)
405
406 * Websites: added option to query only sequences containing sumtrigger
407 events
408
409 * Websites: added option to group by date (year, month, night) for runs
410 and sequences and enabled that combining of different group-bys,
411 e.g. status, date and source is possible
412
413 ;automatic analyis
414
415 * Rewritten producing plots in the web.
416 New plots, namely the output of plotoptical.C (extinction curve from
417 KVA), plotstat.C (status of the automatic analysis (percentage of
418 processed, analysed data etc.)) and plotusage.C (statistics of the
419 condor usage in the data center) has been are available now next to the
420 plots of plotdb.C
421 Mean values from the plots (output of the macro) are provided in a
422 txt file now.
423 The creation of the plots for callisto, star and ganymed in the web is
424 now steered via database. Consequently the plots are faster and
425 reliable up-to-date.
426 For all plots, a new layout is available facilitating the browsing
427 through the plots and providing additional information on the
428 displayed values. (tabs.php) These plots are linked from the DB
429 websites and the wiki.
430
431 ;statusdisplay
432
433 * The ''Loop'' entry in the menu bar now contains an option to pause
434 the loop and to process single events.
435
436 ;merpp
437
438 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
439 instead of RunHeaders)
440
441 * Now allows to merpp files newer than 2008/09/03.
442
443 * Added fixes for wrong (wrong or double) run- and file-numbers
444 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
445
446 ;callisto
447
448 * Extracting the pulse position for the pulse position check events
449 with sum trigger were denied. This decreased the statistics
450 extremely and therefor the resulting puse position was calculated
451 quite weak. Now sum events pass the calculation if and only if they
452 have also a level 1 trigger.
453
454 * the extraction of pedestal events and pulse position from the
455 first data events is now more automatic and makes sure that
456 a more precise number of events is extracted independent of
457 the ratio with which pedestal events or events with signals
458 are contained in the data.
459
460 * Updated Muon calibration constants for all MUX data (teh changes were
461 all smaller than 5%)
462
463 ;star
464
465 * For the calculation of the effective on time all sum-triggered events
466 were skipped. Now all Level1-triggeres events will pass. This might
467 result in a slight inaccuracy of the effective on time.
468
469 ;ganymed
470
471 * If the source position is more than 1deg away from the camera
472 center an error is raised now.
473
474 * Hopefully fixed the bug ''ganymed crashes when resized''
475
476 ;sponde
477
478 * Fixed a problem which causes the fitted spectral slope to be displayed
479 incorrectly. If you use MJSpectrum::FormFlux in your macros make
480 sure that the parameter 0 of your fit is negative.
481
482 * Added a histogram showing the read source position of your MCs
483
484
485
486== Version 2.1.1 (2008/08/04) ==
487
488 ;Database
489
490 * Added the median number of photo electrons from the calibration
491 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
492 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
493
494 * Added fTotOnTime, which is the on-time as given by the run-headers
495 (in contradiction to fAbsOnTime which comes from CC)
496
497 * Added new primaries for the new data structure (Magic II): for the
498 tables dealing with sequences (SequenceBuild Status, Sequences,
499 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
500 this is the telescope number (fTelescopeNumber) for the tables dealing
501 with runs (RunData and RunProcessStatus) this is in addition the file
502 number (fFileNumber)
503
504 * Added column fPriority to the status tables to be able to steer the order
505 in which the data is processed. As default the run, sequence and dataset
506 number are used.
507
508 ;automatic analyis
509
510 * Adapted scripts to the new data structure: They can handle now different
511 telescopes (getting the information as usual from the database).
512 The paths for Magic 2 are not yet implemented.
513
514 ;general
515
516 * should work now with root 5.20/00 (please note that root 5.20/00
517 we encounter crahses in the status display which are ot yet
518 understood)
519
520 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
521 instead of the base name of the file. This makes them easier to
522 access from the code
523
524 * Default Monte Carlo names in MSequence do not require the _E at
525 the end anymore
526
527 * where abrrevating a sequence file with a sequence number is possible
528 also "telescope:sequence" is now accepted, e.g.:
529 star 2:2000123 --out=output
530 see the programs' help for more details.
531
532 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
533 from the database. See the constructors for more details.
534
535 * MReadTree now supports friends
536
537 * MReadTree can now read also files not written by MARS and store
538 the data encapsulated in emulated MParContainers
539
540 * added a new starguider calibration valid since 15.1.08
541
542 ;showplot
543
544 * showplot can now read more than one file at once. This is especially
545 inetersting if reading files containing pure canvases
546
547 ;merpp
548
549 * we merpp the dc currents now also from the camera reports (they have
550 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
551
552 * In the automatic analysis we omit merpping of the currents from the
553 caco files and use the lower rate camera reports from the cc files
554 instead
555
556 * merpp has been redisigned to allow merpping of the cc-reports
557 of a whole sequence. This allows to design a very simple analysis:
558 mkdir output
559 ./callisto 100776 --out=output
560 ./merpp 100776 output
561 ./star 100776 --ind=output --out=output
562 Instead of the sequence number also sequence files are accepted.
563
564 * Implemented a fix for run-numbers between 1001348 and 1001396
565 which were incorrectly assigned by the cc.
566
567
568 ;callisto
569
570 * added a filter again which was was removed in the last release.
571 it removed the most brightest events. This should not change
572 any analysis result because these events are so bright that
573 they cannot be analysed anyway, but the bad-pixel plots doesn't
574 show outliers.
575
576 * updated muon calibration constants for the periods 51-57,
577 58-63 and 67-
578
579 ;star
580
581 * The camera currents are now displayed with the rate of the camera
582 reports instead of the caco reports
583
584 ;ganymed
585
586 * if mc camera files are new enough (>=8) the source position in the
587 camera is now calculated from the stored telscope and shower
588 orientation (Note, that this might not be suitable in all cases
589 depending on the aim of the study. These case still needs
590 implementation)
591
592
593
594== Version 2.1 (2008/06/18) ==
595
596 ;Database
597
598 * introduced average temperature and wind speed from star-files
599
600 * introduced average values from Pyrometer (mainly Cloudiness)
601
602 * introduced the ratio of accepted calibration events in the
603 calibration run
604
605 * introduced the average rates of the different trigger pattern,
606 e.g. the rate of pedestal and calibration events, from the signal-file
607
608 ;general
609
610 * fixed GroupBy options in plot*.C macros
611
612 * only display KVA points (not the Tuorla points) in plotoptical.C
613
614 * all programs now allow to add resources to the ones from the resource
615 file or overwrite them from the command line. This can be done like this
616 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
617 if something seems to be wrong you can debug what the program is doing
618 using the option --debug-env=3
619
620 * increased the diversity of debug levels. That also means that with -v3
621 you get now less output, i.e. only the output which is important for
622 an analysis. To get more output which helps for debugging try 4, 5 and 6.
623
624 * fixed a problem in the task synchronizing the reading of the reports
625 and the data stream. The effect was that in some circumstances the last
626 events of some trees could have been skipped. Since this is only a
627 very tiny part of the data no severe effect to your analysis results
628 is expected (an exception might be very short, i.e. singel runs,
629 datasets).
630
631 * Dataset file now allow to include the sequence file directly within
632 the dataset file and also allow to exclude single runs from the dataset.
633 (for more details see Class reference of MDataSet)
634
635 * Sequence files now allow for excluding runs from the analysis
636 (for more details see Class reference of MSequence)
637
638 * added code to process the sum-trigger flag
639
640 * the histogram classes MH3 and MHn now support profile histograms
641
642 * the histogram classes MH3 and MHn now support labels at the axis
643
644 * the Random Forest Train-classes (MJTRain*) now store the used datasets
645 in the output file
646
647 * the MFMagicCuts have a new option to allow a linear area cut (for
648 special studies)
649
650 * The liniking of the shared object is now done into a file defined
651 by 'mktemp'. This should be a local file system which accelerates
652 liniking a lot.
653
654 * The code has been prepared for compilation with root 5.18/00d
655
656 * The MHEnergyEst histogram now shows the distribution of
657 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
658 and (Eest-Emc)/Emc vs Emc.
659
660 * fixed mars (event display) for merpped raw-data and MC data
661
662 * adapted the synatx of sequence files to allow for the new run/file
663 scheme. For more details see class description of MSequence
664
665 ;showplot
666
667 * Added support for tiff files
668
669 * Added support for csv files (tables containing tab number,
670 name and title)
671
672 * Tabs now can have a title which is displayed in the postscript file
673
674 * When multiple file are written at once (e.g. pngs from a display)
675 it is now possible to use the tab name and or tab number in the
676 file name. For details see showplos's help.
677
678 ;merpp
679
680 * Implemented cc file version 2008-02-20/0
681
682 * Implemented cc file version 2008-05-19/0
683
684 * With new options merpping can be restricted (in addition to the
685 run-number) also by telescope and file number.
686 For details see "merpp --help"
687
688 * Implemented raw data format 11 (the most important change, except
689 from plenty of changes in the format definition, is the addition
690 of the file-number in the header) If nobody makes a mistake this
691 format should have the advantage that it is by definition forward
692 compatible, so old programs will be able to read newer formats.
693
694 * Added Pyrometer information to default output (stored in a new Tree
695 Pyrometer, needs a complete new merpp, i.e. new calibration)
696
697 * Merpping (also update) can now be restricted to one single report.
698 For example:
699 If you want to update an old file with Pyrometer information call
700 merpp --only=Pyrometer --update
701
702 ;callisto
703
704 * in the pedestal processing now at least 50 processed events are
705 required for succeeding.
706
707 * the signal and calib files now contain also the sequence information
708
709 * the two MPedestalCam in the calib file now have proper names
710 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
711
712 * Both pedestal cams now contain the number of events processed
713
714 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
715 i.e. for the extraction of the calibration pulses basically the average
716 over all events of the first slice instead of all slices was used.
717 Since pedestal and calibration constants are continously recalculated
718 this only effected the very first events of every sequence.
719
720 * For the extraction of the position of the maximum sample now the
721 extraction range is set automatically to the extraction window,
722 before the whole accessible range was used.
723
724 * If the number of samples in the events and the number of samples
725 in the run-header disagrees now an error is raised (this can
726 happen in not well simulated Monte Carlo files)
727
728 * In the case of MUX-data pedestal events with the lvl1 trigger flag
729 could survive into the pedestal calculation -- fixed.
730
731 * Tab "TrigPat" added showing the distribution of the trigger pattern
732 as found in the run-files (normalized with the run length)
733
734 * The selection of events from the trigger pattern has been improved.
735 If the trigger pattern is corrupted events won't pass anymore.
736
737 * Added a new command line option --dev-null to suppress output of
738 Y-files (this is useful for test cases)
739
740 * added a new tab "CalPos" showing the arrival time of extracted
741 interleaved calibration events
742
743 * Using the new --test switch you can now calibrate the calibration
744 file
745
746 ;star
747
748 * the star file now contains also the sequence information
749
750 * Added a new command line option --dev-null to suppress output of
751 I-files (this is useful for test cases)
752
753 * Tab "Rate" added showing the distribution of the trigger pattern
754 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
755 the Y-files (normalized with the run length)
756
757 * The effective on-time calculation doesn't use events with only
758 sum-trigger anymore
759
760 * The data in the MHWeather tab has been reorganized. The never
761 working solar radiation has been removed and the data from
762 the pyrometer (cloudiness, air and sky temperature) is
763 displayed in addition.
764
765 ;ganymed/sponde
766
767 * Now data points are even shown correctly if they have error bars larger
768 than one sigma. Points with null or negative significances are omitted.
769
770 * DrawNicePlot now allows to set a projection range
771
772 * Updates pointing models. One is applied after the implementation
773 of the new LUTS in August, the other one is applied after the
774 next major change of the pointing model in October. Note that
775 these models are preliminary and give wrong results below Zd=65deg
776
777 ;sponde
778
779 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
780
781 * a new option "--force-runtime" is available. In case of very short
782 datasets (for light-curves) which are in the order of a few
783 minutes the calculated effective on-time is not very acurate because
784 it is quantizised in the order of a minute. Therefore you can switch
785 to using the real run-time instead (remakrt: this ignores any
786 dead-time!)
787
788 * a more analytical way is used to "fill" Monte Carlos into regions
789 of impact parameters which have not been simulated because the
790 trigger efficiency is assumed to be 0.
791
792 * estimated sensitivity curves for hi and lo zenith angles are shown
793 scaled to the correct observation time and collection area
794
795 * the Monte Carlo events after cuts are now written to the output file
796 if an output file given
797
798
799
800 *** Version 2.0 (2007/09/03)
801
802 - database: the position used for the pulse pos check was missing
803 in the callisto output and could thus not be filled into the DB.
804 Also the old values seemed not exactly the PulsePos used for
805 teh check.
806
807 - general: Resource file now allow an Include-Resource, i.e. you can
808 read a resource file with default settings, include it in your
809 resource file and overwrite the settings in your file. More than
810 one include file is allowed. Inclusions can be iterative.
811 Include: mydefaults.rc yourdefaults.rc
812 The resources in the first file have higher priority than the
813 second file.
814
815 - general: Now the output files (calib*.root, etc) also contain the
816 resource file (to check it open it in the TBrowser and choose Print()
817 from the context menu)
818
819 - general: Dataset files now allow to overwrite the default path
820 to search for sequence and data files. Note, that the program
821 option and individual resources will overwrite it. For example:
822 SequencePath: /magic/montecarlo/sequences
823 DataPath: /magic/montecarlo/star
824
825 - general: Fixed a problem with variables in MDataPhrase. It seems
826 that only optimdisp (didn't work) was effected.
827
828 - general: Some improvements to the optim and train processing. For
829 example the ststud window now got a proper title.
830
831 - general: The "Status Display: " was removed from the window title
832 within an Eventloop.
833
834 - general: added a new flexible histogram-class (MHn) which can be used
835 for example in testing after optimizations or training to produce
836 user defined histograms.
837
838 - general: The Random Forest now allows attaching an evaluation
839 function which is applied to its output. This allows to train
840 on whatever you like (eg. train on log10(energy), but return
841 energy)
842
843 - general: The Random Forest training of energy (trainenergy.c) and
844 disp (traindisp.C) has been improved by more graphical output to
845 judge the result.
846
847 - general: The training of energy (trainenergy.C) has been improved
848 a lot by training on a different quantity than energy. It gives
849 a result which is highly independant of the source spectrum
850 and shows lower bias than all other options.
851
852 - general: Dataset files are allowed to contain collections of
853 datasets. For more details see the class reference of MDataSet.
854
855 - general: The default WobbleMode in a datset file now (if not
856 overwritten) is "auto", i.e. wobble mode is set if the dataset
857 doesn't contain off-sequences.
858
859 - merpp: Merpp can read file format version 9 now. Please realize
860 that for file format version 9 the extraction range is different
861 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
862 the first and last 15 slices have been removed from all MUX data.
863
864 - mars: Similar to writing movies you can now select events which
865 should be displayed in your display. Therefore add the following
866 lines to your mars.rc:
867 MFEvtNumber.FileName: ganymed00223552.root
868 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
869 The input file can be a ganymed-file after (ganymed*.root) or
870 before (ganymed*-summary.root) file. For example to select all events
871 from your on sample after cuts (excluding the ThetaSq cut) use
872 MFEvtNumber.Selector: DataType.fVal>0.5
873 To show all events from your on-sample after quality cuts
874 use the summary file instead.
875
876 - mars: new ways to call mars are implemented. Instead
877 of calling
878 mars filename.root
879 you can now also use
880 mars sequence.txt
881 or
882 mars sequence.txt inputpath
883 or replace sequence.txt by the sequence number if the default
884 sequence file should be used.
885
886 - mars: The default size has been increased
887
888 - mars: There are two new heckboxes which allow to switch off
889 the calculated image parameters
890
891 - callisto: was broken for MCs... fixed.
892
893 - callisto: improved calculation of spline coefficients a lot. This
894 leads to a further improvement of the event rate calibrating MUX
895 data of about 15% (175evt/s instead of 150evt/s)
896
897 - callisto: finally the raw data we read is now real 16bit (with
898 10bit precision) for MUX data and not a stripped 8bit number
899 anymore. Due to scaling of the numbers (without precision loss
900 into an [0-256[ range, the final numbers for pedestal, pedestalrms
901 and extacted signal don't change. However, at all places where
902 raw data is directly accessed (eg. saturation and variation
903 limits in the signal- and pedestal-extraction) the numbers
904 refer still to the data's 16bit range.
905
906 - callisto: The maximum arrival time difference used in the bad
907 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
908 for both, old FADC and MUX-FADC, data.
909
910 - callisto: Be aware that callisto is now calibrating the arrival time
911 in nanoseconds rather than time slices. Also all following tasks
912 have been changed to assume ns units now. If you star data
913 calibrated with an older version it might be necessary to adapt
914 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
915 to obtain optimal results. The plot in the PulsePos tab
916 will now be in ns, too. This might also mean that the Muon
917 analysis in star might not work as perfect as expected as long
918 as old files read in.
919
920 - callisto: The calibration constants of earlier updates got lost
921 somehow. All constants have been updated.
922
923 - star: The PSF is now determined from the profile of the ArcWidth
924 instead of arcwidth/radius. The old way gave to much weight
925 to the bins with low statistics. The reference lines have been
926 updated.
927
928 - star: For speed reasons events suitable for the muon analysis
929 are now also preselected by fConcCOG<0.1 which seems to be a very
930 good preselector for muons.
931
932 - star: is now calculating a new timing parameter the Slope along
933 the major and minor axis of the shower. Therefore a numerical
934 solution of a line-fit is used. To use MHillasExt.fSlopeLong
935 and MHillasExt.fSlopeTrans don't forget to multiply it with
936 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
937
938 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
939 have been removed from MNewImagePar. They have never been good for
940 anything.
941
942 - star: Implemented a new recursive algorithm which is supposed to be
943 faster. Also implemented new cleaning oiptions, which are:
944 + CleanLevel0:
945 The cleaning level above single core pixels can be kept
946 + KeepIsolatedPixels:
947 Define whether single core pixels should be kept
948 + TimeLevel1:
949 The coincidence window in nanoseconds to single used neighbors
950 + TimeLevel2:
951 The coincidence window in nanoseconds to two used neighbors
952 + PostCleanType:
953 MOde in which a time dependent post cleaning should be applied
954 0: No post cleaning
955 1: Require for each used pixels at least one used neighbor
956 within a time-window of CleanLevel1
957 2: Require for each used pixels at least two used neighbor
958 within a time-window of CleanLevel2
959 3: Require first two and second one used neighbor
960 within a time-window of CleanLevel1 and fCleanLevel2
961 respectively
962 + RecoverIsolatedPixels:
963 - recoveres isolated core pixels if they have a used neighbor
964
965 - mars/star: The new default cleaning is:
966 + CleanLevel1: 6.0
967 + CleanLevel2: 3.0
968 + CleanTime1: 1.75
969 + CleanTime2: 1.75
970 + PostCleanType: 3
971
972 - star/ganymed: The old spark-cuts have been replaced by new ones.
973 These new spark cuts have been cross checked with the sequences
974 84720 (before splitter), 101041 (after splitter) and 223539 (new
975 FADCs). In all cases they seperate pretty well, but of course not
976 perfect. Monte Carlos have suggested to tighten the cuts a little
977 bit further at low sizes. This has been done.
978
979 - ganymed: IMPORTANT - The spark cuts have been changed to match
980 all available data more or less well. This might mean that for
981 YOUR data there are still sparks visible.
982 Whenever you do an analysis you have to make sure that NO sparks
983 survive your cuts!
984
985 - ganymed: The old hadronness and size cuts have gotten new indices
986 (10, 11). The old indices 8 and 9 now mean an additional condition
987 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
988 If you want to switch off this cut just move the line far away enough,
989 e.g. by setting c[9] to -500. Please update your ganymed.rc files
990 accordingly!
991 The unit of c[9] is deg. It is the dist at which your cut will
992 cross the slope==0. The unit of the slope is ns/deg. So if
993 you readin files calibrated with an older Mars-version you
994 have to adapt the default value for c[9] to the FADCs:
995 - Multiply by two for the MUX FADCs (run number > 200.000)
996 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
997 - Multiply by 42 for the meaning of life (run number = 200.000)
998
999 - ganymed: The old Cut0 is now called CutQ and is calculated before
1000 the source position is caluclated. If you need a quality cut
1001 including source dependant data (be very carefull with this!)
1002 you have to use Cut0 instead.
1003
1004 - ganymed: now properly supports three off regions in wobble mode.
1005 It will be the default from now on in ganymed_wobble.rc. To change
1006 the number of off-regions use
1007 NumOffSourcePositions: 1
1008 in your ganymed.rc. Also by default no off-theta cut will be done
1009 anymore so that you will get a background level higher than the
1010 signal level in your ThetaSq plot for ThetaSq>0.2.
1011 Due to this be carefull changing the scaling mode away from
1012 "None". You will underestimate your signal if your scale interval
1013 is not properly set.
1014 (Rem: ThetaSqN is no longer needed)
1015
1016 - ganymed: is now storing the events of all (on- and off-)
1017 source positions even in the case of more than one off-source
1018 position. This should allow sponde to work properly and the
1019 energy estimation is done correctly in all cases (without any
1020 "nearest position" trick)
1021
1022 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
1023 with a real pointing model for the starguider is done, calibrated
1024 with more than thousand tpoints taken from this date on.
1025
1026 - ganymed: was broken for Wobble-MCs... fixed.
1027
1028 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
1029 has changed. Note that your old ganymed.rc will be incompatible
1030 with the new algorithms! Please check the ganymed.rc files and
1031 the class description of MFMagicCuts for more information.
1032 It is recommended at the moment to use identical Disp-Parametrizations
1033 for on/off- and wobble-mode. If cuts are optimized only
1034 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
1035 should be optimized. All other values should be kept as they are.
1036 If you want to do an anylsis without timing a parameters, you can
1037 switch off the timing cuts by seeting parameter 7 to a very small
1038 value (eg. -99). To remove the slope parameter from the disp
1039 paremtrization set parameter 8 to 0.
1040
1041 - ganymed: The distribution of observation time versus zenith
1042 angle is now shown for off- AND on-data.
1043
1044 - ganymed: The contents of the source position plot are no longer
1045 averaged, thus a lot of (fake) events between the two wobble
1046 positions have disappeared.
1047
1048 - ganymed: There is a new tab "CutT" it contains the VsSize plots
1049 with the CutT, whihc is defined in ganymed.rc, applied. It
1050 is resonable to use your theta-cut for it, to see if there is
1051 something strange (sparks!) in your signal-region.
1052
1053 - ganymed: To choose a dataset from a collection in a dataset file
1054 use the new command line option "--dataset=12345"
1055
1056 - optim, sponde: should now properly support three off-regions.
1057 Just produce your ganymed summary files with three off-regions.
1058 optim and sponde will automatically get all off events from
1059 all off-regions from this file. Please do not forget to
1060 set the scaling in optimwobble.C properly:
1061 fit.SetScaleUser(1./3);
1062 it is not yet read in automatically (will follow soon).
1063 In the case of fixed Scale you can also use
1064 cuts.SetThetaCut(MFMagicCuts::kOn);
1065 no off-cut needed.
1066 Be carefull in case of three off-regions when switching on
1067 scale mode. Make sure that the scale interval is set correctly.
1068
1069 - sponde: sponde.rc and sponde_onoff.rc are now idetical
1070
1071 - sponde: the resouce files have been rewritten with a lot of
1072 comments and a well working parametrization for an energy estimator
1073
1074 - sponde: In the estimated energy versus monte carlo energy plot the
1075 contents where exchanged.... fixed.
1076
1077 - sponde: the so called "accurate"-mode has been removed. It didn't
1078 give any improvement in accuracy, only decreased execution speed.
1079
1080 - sponde: the so called "simple"-mode has been removed. It didn't
1081 give any improvement in simple.
1082
1083 - sponde: the so called "refill"-mode has been removed. It was anyhow
1084 not implemented.
1085
1086 - sponde: now checks whether the theta distribution of your on-data
1087 and the theta-distribution of your Monte Carlo sample (after
1088 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
1089 sample is incomplete) execution is stopped. Execution can be forced
1090 using the new option --force-theta. Use this option with care!
1091
1092 - sponde: Proper collection areas can now be constructed also from
1093 Monte Carlo samples generated with different maximum impact
1094 parameters. Note that in previous version you neither got
1095 a warning or failure, nor was there any obvious sign that the
1096 collection area was overestimated due to usage of files with
1097 different maximum impact parameters.
1098
1099 - sponde: If MC files with different lower energy limits are used
1100 the primary MC spectrum is artificially completed down to the
1101 lowest energy used at all. WARNING: that this gives correct
1102 collection areas ONLY if none of the events in this region would
1103 survive your cuts at all.
1104
1105 - sponde: the output file now contains more information about
1106 the spectrum (eg. the full 2D collection area histogram).
1107 Note, that this information can only be written to the file
1108 if it is stored automatically via command line argument.
1109 If you only store the status display from within the display
1110 the information is lost.
1111
1112 - sponde: added a new tab "Disp". It shows the residual of the disp
1113 (Disp-Dist) versus several parameters and it is meant to judge the
1114 quality of the disp estimator. In the ideal case the residual is zero
1115 and doesn't depend on any variable. The tab is displayed after
1116 CutQ and Cut0.
1117
1118 - sponde: added a new tab "Energy". It shows the residual of the
1119 energy (lg(estimated energy)-lg(monte carlo energy)) versus
1120 several parameters and it is meant to judge the quality of the
1121 energy estimator. In the ideal case the residual is zero
1122 and doesn't depend on any variable. In reality even a good estimator
1123 can show residuals versus Monte Carlo energy. The tab is displayed
1124 after all cuts.
1125
1126 - sponde: added a new tab "EventDist" showing the unweighted real
1127 absolute number of events of your sample after cuts. This tells
1128 you how many events with this energy you had in your MC files.
1129 The same information you get from the error bars of the weighted
1130 histograms, but this is less intuitive.
1131
1132 - sponde: The spectrum plots now show the crab- and 1553-spectrum
1133 for comparison. It is not meant to show these curves in
1134 publications, they are only for production.
1135
1136 - sponde: The OriginalMC tree with the events produced by corsika
1137 is now processed only once
1138
1139 - sponde: Finally fixed most annoying bug, which has effected the
1140 last bin of the collection area. It was the problem that binnings
1141 of root histograms are from 1 to n (included) but there was a C-like
1142 loop in sponde from 0 to n (excluded). Now the loop also includes
1143 correctly under- and overflow-bins. The worse thing with this is,
1144 that for the events in the highest bin not only the bin-content
1145 was wrong, but also the weights applied to these events, which could
1146 in pricipal effect also other parts of the distribution (eg. due
1147 to energy estimation). Fortunately it effected only a few events
1148 in most cases.
1149
1150
1151
1152 *** Version 1.2 (2007/05/14)
1153
1154 - database: The database now has two new values Unsuitable50 and
1155 Unsuitable01. They express the number of pixels which are
1156 unsuitable for more than 50%, respectively more than 1%, of
1157 all calibrated event. It is a more accurate number than the
1158 previously used numbers, because they only take the first
1159 calibration (ignoring the interleaved calibrations) into account.
1160
1161 - database: The database now has two other new values UnsuitableMax and
1162 DeadMax. They express the maximum number of pixels which were
1163 unsuitable, respectively dead, during the sequence. Because
1164 of high pedestal rms (cars passing) a few events with very high
1165 numbers of unsuitable pixels can happen. Not to suffer from this
1166 effect we don't take the highest 0.1% of the numbers into account.
1167
1168 - general: fixed a bug which caused callisto and star to stop working
1169 properly because the callisto output was currupted
1170
1171 - general: a script called scripts/makemovie has been added which
1172 simplified the process of producing several movies from a single
1173 sequence with different setup.
1174
1175 - callisto: Some more code cleanup. Started to remove old obsolete
1176 code from cvs.
1177
1178 - callisto: The extraction of the pedestal with the extractor was
1179 not random. It seems that extracting at one position is still biased
1180 (for example in the first or last slices we could still suffer from
1181 switching noise) Now it is completely random.
1182
1183 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1184 pedestal files) individual pixels could be skipped due to high
1185 variations. This was already the case for the pedestal extraction
1186 from the lo-gains since the beginning and properly handled
1187 there, but was introduced in the extraction from the pedestal files
1188 a while ago. To calculate the average value it was still divided
1189 by the number of events procesed not by the number of summands
1190 really summed. This let to a pedestal which was a tiny amount too
1191 small (for a few piels in the order of 0.1%). This led to an slightly
1192 positive offset of the randomly extracted pedestal for a few pixels.
1193 I doubt that this has a big effect on the result, because the effect
1194 on the individual numbers is quite small. Due to this it is suggested
1195 that you rerun your calibration to make sure you are without any
1196 avoidable bias.
1197
1198 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1199 the median rms of the absolute arrival time and expressed in significance
1200 levels. This replaces the old meaning of an abolute upper limit. An
1201 absolute upper limit doesn't make much sense, because in our data
1202 all arrival times are shifted at the same time (in fact it might be
1203 a shift of the artificial trigger w.r.t. to the light flash).
1204
1205 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1206 of the number of unsuitable pixels over the whole sequence. This
1207 is usefull mainly to judge if an intermediate calibration had
1208 problems.
1209
1210 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1211 of the number of dead pixels over the whole sequence. Dead pixels
1212 in this context are unmapped pixels, i.e. pixels which could not
1213 be interpolated, and thus are ignored in the further analysis.
1214
1215 - callisto: It is now possible to use the position of the maximum
1216 of the spline as arrival time instead of the leading edge even
1217 when using the integral for the signal. Therefor set the extraction
1218 type to kIntegralRel ("IntegralRelative") and the relative height
1219 ("HeightTm") to -1:
1220 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1221 MJPedestalC1.ExtractSignal.HeightTm: -1
1222
1223
1224
1225
1226 *** Version 1.1 (2007/04/27)
1227
1228 - general: The new class MGeomCamDwarf contains the camera geometry
1229 for our prefered Dwarf camera and can be used to create general
1230 geometries of roundish or hexagonal cameras.
1231
1232 - mars: The default cleaning is now abolute 8.5/4.0.
1233
1234 - mars: The resource file mars.rc now contains examples for MUX data
1235
1236 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1237 data containing only 10-bit information is still cooked down to
1238 8-bit, by cutting away the lowest 8-bit.
1239
1240 - merpp: When reading raw data the data is now stored in a single
1241 array. The lo-gain array is obsolete. The interface stays the same.
1242
1243 - callisto: To process the new MUX data use the resource file
1244 callisto_mux.rc
1245
1246 - callisto: The -root and -raw options to read merpped raw data have
1247 been removed
1248
1249 - callisto: If the -mc option is given the sequence-name can now be
1250 replaced by the MC sequence number
1251
1252 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1253 -mc option can now be omitted
1254
1255 - callisto: Started further simplification by removing obsolete
1256 dependancies on MCalibIntensity*Cams.
1257
1258 - callisto: removed unsused intensity calibration from MJCalibration
1259 for further simplification
1260
1261 - callisto: for simplification removed references to
1262 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1263 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1264 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1265 (this should at minimum change nothing at all, and at maximum
1266 improve thing if these containers where somewhere not handled
1267 properly)
1268
1269 - callisto: Added the option to write an event movie. Please use
1270 this option with care (huge files) but exessively to understand
1271 our events. For further documentation please refer to the
1272 IACT wiki
1273 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1274
1275 - callisto: Improved binning for the pulse position check histogram
1276
1277 - callisto: The code calculating the pulse position checknow takes
1278 the pedestal into account
1279
1280 - callisto: The arrival time is now stored with full precision this
1281 helps to get rid of artefacts in histograms. For the signal this
1282 is not necessray because it is displayed in log-scale anyhow
1283
1284 - callisto: Fixed a problem with internal exclusions. Pixels which
1285 have once been marked as unsuitable didn't get the necessary
1286 histograms filled anymore to be rechecked with each interleaved
1287 calibration.
1288
1289 - callisto: The relative arrival time resolution (the rms of the
1290 relative arrival time offset) is now checked against its
1291 median and the median deviation, instead of the average
1292 plus an absolute offset.
1293
1294 - callisto: The relative arrival time offset is now calculated
1295 w.r.t. its median not w.r.t. to an artificial reference pixel.
1296
1297 - callisto: The relative time calibration now marks pixels with
1298 outlaying offset as unsuitable
1299
1300 - callisto: The interleaved relative time calibration has been switched
1301 on. The advantage is that pixels which are marked as outliers
1302 now can recover. An improvement over time is not expected, because
1303 the relative time calibration seems stable.
1304
1305 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1306 option can now be omitted.
1307
1308 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1309 or the option "-mc" is specified as default the monte carlo datacenter
1310 paths (/magic/montecarlo/...) are used if not overwritten in the
1311 dataset file.
1312
1313 - ganymed: The output files now contain run- and event-number for all
1314 events, accessible as RunNumber.fVal and EvtNumber.fVal
1315
1316 - ganymed: Added a plot showing the source position in the camera also
1317 for wobble mode
1318
1319 - ganymed: In addition to the existing task which can be setup to
1320 be executed after Cut1 a final task called "EstimateEnergy"
1321 has been added, executed before writing the final output
1322 (ganymed00000000.root). The task setup in all three cases
1323 can be choosen individually. (For all three(!) cases you
1324 can for example choose MRanForestCalc. For examples see all
1325 sponde*.rc and all ganymed*rc)
1326
1327 - ganymed: If a container "MEstimatedEnergy" is found in the
1328 parameter list (eg. because it was setup by MEstimateEnergy)
1329 it will be written to the output file.
1330
1331
1332
1333 *** Version 1.0 (2007/02/16)
1334
1335 - database: Website to plot values from the database has been added.
1336
1337 - database: The rate of spark events as found by star is now kept
1338 and the rate after cleaning is now with spark events subtracted
1339
1340 - general: The changes to the interpretation of phrases lead to
1341 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1342
1343 - general: Added example files how you can create your own calendar
1344 (eg. as christmas present) with Mars. Just run
1345 root macros/tutorials/calendar.C
1346
1347 - general: Added a possibility to display grouped data in the plotdb.C
1348 macro (and similar macros). This allows to plot hourly, nightly,
1349 weekly, monthly and yearly averages.
1350 For more details see the plotall function of the macro
1351
1352 - general: fixed the error display of the camera display. It showed
1353 wrong results.
1354
1355 - general: fixed a memory leak when reading many MStatusDisplays
1356
1357 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1358 between a spherical and a parabolic mirror
1359
1360 - callisto: We have a new pulse position check which takes the properties
1361 of the extractor automatically into account. So no need to set
1362 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1363 left is done. If possible the lo-gain extraction start and hi-gain
1364 extraction end is changed accordingly. If no proper extraction range
1365 can be set (hi-gain too much to the left) an error is raised.
1366
1367 - callisto: New swapped pixels have been found and corrected
1368
1369 - callisto: Redone the signal extraction this includes:
1370 + Unified the algorithms to extract the pedestal for all pedestal
1371 extractions done
1372 + Unification of hi- and lo-gain into one array
1373 + Unification of hi- and lo-gain extraction for Spline and
1374 Digital Filter (means now exactly the same algorithm is used,
1375 not a copy-and-pasted one)
1376 + Store pedestal subtracted data in a common place
1377 + Improved extraction algorithms. If the algorithms search a
1378 maximum but don't find one they don't return the maximum anymore
1379 + Improved the extraction such that a information for signal
1380 and time which is consistent is returned
1381 + replaced the numerical spline with a (not slower) analytical
1382 solution
1383 + Lowered the saturation limit from 250 to 245 to make sure that
1384 we are far away in all pixels from problems with the clock-noise
1385 + The start of the lo-gain extraction is calculated from the hi-gain
1386 arrival time. In case of saturation an estimation is used.
1387 + the hi-gain window was extended to slice 16. This allows extraction
1388 of very late pulses in single pixels or of huge hadron showers.
1389 + Now uses the lo-gain extraction range for pedestal extraction,
1390 not the hi-gain range in the lo-gain
1391
1392 - callisto: New hi-/lo-gain calibration constants have been produced
1393 for all periods from the statistic of the whole period. They are
1394 now used automatically depending on the periods. The old constants
1395 where deviation in avarega about 2%-3%. The constants are very
1396 stable from period to period (<<1%) except for exchanged channels.
1397 In a few cases the constants used so far were off by 1%-2% (maybe
1398 temperature effects?)
1399
1400 - callisto: To gain obsolete space we do not write the
1401 MPedestalFundamental anymore. Also calibration and bad pixel
1402 treatment is not done for it anymore because it has never been used.
1403
1404 - callisto: Fixed a bug in the seuqence handling which caused the
1405 light condition to be ignored
1406
1407 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1408 basically the same as "Cleaned" but the distribution devided into
1409 the events fullfilling a spark cut or being rejected by it.
1410 This cut can be changed from star.rc (see example inside) by
1411 the "SparkCut" directive
1412
1413 - star: Star displays now the average individual pixel-rate (IPR) versus
1414 time and the average discriminator threshold (DT) of all pixels.
1415
1416 - optim: fixed a problem with the optim-macros which was due to a bug
1417 in the new phrase parsing
1418
1419 - ganymed: To get a nice FalseSource plot (instead of the all-information
1420 debug plot displayed as a standard plot) use the context menu
1421 somewhere between the two upper plots, click on "DrawNicePlot"
1422 and enjoy the result. (It is the same context menu which contains
1423 the other options)
1424 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1425
1426 - ganymed/optim/train: The cut program, trainings- and optimization
1427 macros could run with less files found than expected from the
1428 sequence-files. No the execution is stopped in this case.
1429
1430 - ganymed: now stores the dataset in the output file with all information
1431 contained (as sequence number, sequence path, data path) so that the
1432 used dataset file can be recreated complete from the output
1433
1434 - sponde: now also allows the uasge of random forest
1435
1436 - sponde: added a plot showing the cut efficiency
1437
1438 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1439 errors (eg. effecting the collection area) because the errors of the
1440 two histograms were swapped in the calculation, which makes a difference
1441 in the case the histograms contains weighted events. Aditionally the
1442 totalarea was incorrectly taken into account, which results in too small
1443 errors, which makes a difference at low statistics were the errors
1444 or the collection area dominate.
1445
1446
1447
1448 *** Version 0.10.3 (2006/10/23)
1449
1450 - database: Implemented ObservationMode flag in websites.
1451
1452 - database: For sequences there is now also the stoptime available on the
1453 websites.
1454
1455 - database: Removed ManuallyChanged flag from sequence-info websites,
1456 as it is not needed anymore with the new sequence building algorithm.
1457
1458 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1459 Class for calculation of confidence intervals (upper limits).
1460 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1461 Please read the class instruction of TRolke for more information.
1462
1463 - general: The programs now return 0xfe if the requested resource file
1464 doesn't exist.
1465
1466 - general: Errors comming from root itself are now not output to
1467 stderr anymore but to our default (colored) log-stream.
1468
1469 - general: Changed the interface to TFormula such that now everything
1470 is parsed by TFormula, which should allow to use phrases even
1471 without paranthesis correctly parsed.
1472
1473 - callisto: replaced the AdHoc number of effective integration slices
1474 in the digital filter by an average of the correct number, averaged
1475 over all possible set of weights. This also gives correct numbers
1476 for the lo-gains which were totally wrong before.
1477
1478 - callisto: drastically reduced memory consumption by not storing
1479 all intermediate calibration results in memory anymore (we might
1480 write them into a file in the future)
1481
1482 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1483 debug plot displayed as a standard plot) use the context menu
1484 somewhere between the two upper plots, click on "DrawNicePlot"
1485 and enjoy the result. (It is the same context menu which contains
1486 the "DrawAll" option)
1487 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1488
1489
1490
1491 *** Version 0.10.2 (2006/10/15)
1492
1493 - general: changed the building of the sequence files such, that
1494 the source-/project name in case of wobble-sources is not the
1495 source/project of the first data run anymore but the new generalized
1496 wobble source/project
1497
1498 - general: Added some functions to MAstro to calculate sun and
1499 moon properties
1500
1501 - general: Added two new macros (starvisday.C and starvisyear.C)
1502 which allow to plot the visibility of several stars in one day
1503 or of one star along one year
1504
1505
1506
1507 *** Version 0.10.1 (2006/10/11)
1508
1509 - general: HTML logging output was distorted... fixed.
1510
1511 - general: Changed the writing of the sequencefiles such that only
1512 as many pedestal files as giving at least 1000 pedestal events which
1513 are nearby the first calibration run are used as pedestal runs
1514
1515 - sponde: In the calculation of the collection area(s) and the
1516 distribution for MOnte Carlo and estimated energy the error
1517 calculation was wrong because root didn't take the errors
1518 properly into account... fixed.
1519
1520
1521
1522 *** Version 0.10 (2006/10/10)
1523
1524 - general: all executables now check consistency of the root version
1525 installed with the root version used for compilation. The return
1526 code in this case is 255.
1527
1528 - general: The algorithm to build seqeunces has been redesigned
1529 completly. It is now more flexible in terms of a resource file
1530 resources/sequences.rc which can be used to partly overwrite
1531 the default algorithm and defined the important part of the
1532 algorithm. It also takes correctly into account several ways
1533 of taking wobble-data. Currently the new algorithm doesn't take
1534 the number of pedestal events anymore into account (so a sequence
1535 could have much less than 1000 pedestal events and data runs are
1536 no-more used instead)
1537
1538 - general: a lot of small changes to make the code compatible with
1539 root 5.12/00 and gcc 4.1
1540
1541 - general: Fixed some warnings thrown if more warnings are switched
1542 on in the compiler
1543
1544 - general: Added a function to MMath which returns the Median of
1545 the distribution abs(y[i]-median) but at 68:32 division instead
1546 of 50:50, which is somehow the median counterpart of the rms.
1547
1548 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1549 even if they are compressed with gzip (recommended compression
1550 is with "-1")
1551
1552 - showplot:
1553 + batch mode creation of image files now works with root 5.12/00
1554 + added support for writing bmp (though it never produces
1555 bmp which can be read by programs like xv or gimp)
1556 + added support for xml
1557 + added new option to start the display with a different size, by
1558 --display-width=nnn or --display-height=nnn
1559 + added options to define the canvas size when the display is started
1560 --canvas-width=nnn or --canvas-height=nnn
1561 the option can also be used for batch-mode conversion
1562 + added an option which automatically fits the display size to the
1563 desktop-size: --auto-size
1564
1565 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1566
1567 - merpp: allow the reports to have 1000ms due to a bug in the camera
1568 program.
1569
1570 - callisto: New swapped pixels have been found and corrected. For
1571 details see MRawRunHeader::FixAssignment()
1572
1573 - callisto: Callisto now raises an error if one of the input files could
1574 not be opened.
1575
1576 - callisto: In some rare cases it could happen that in the signal
1577 extraction of the digital filter the extractor returned nonsense
1578 results due a wrong initializion of a variable (this happens in
1579 cases in which the extracted signal is exactly zero or the
1580 digital filter couldn't slide because of a too small extraction
1581 window, which could happen in the lo-gain extraction)
1582
1583 - callisto: The lo-gains have been marked as valid in some cases
1584 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1585 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1586 smaller than the number of slices (fLoGainWindowSize) needed
1587 by the lo-gain extractor
1588
1589 - callisto: Updated absolute calibration constants (muon calibration)
1590
1591 - callisto: fixed a bug which caused the hi-gain saturation not
1592 to be handled properly in the spline (the position of the
1593 saturation was calculated incorrectly)
1594
1595 - callisto: fixed a bug which gave weird results if hi- _and_
1596 lo-gain could not be extracted properly. In some cases hi-
1597 and lo-gain have not been extracted at all and the random result
1598 got calibrated. In other cases the hi-gain was saturating and the
1599 lo-gain has not been extracted. For this a completly arbitraty
1600 scale factor was applied to the result from extracting the
1601 charge of the saturating hi-gain.
1602
1603 - callisto: improves handling of extracted signal if lo- and/or
1604 hi-gain could not be extracted properly. If no appropriate
1605 calibration of either the signal or the arrival time is possible
1606 the pixel is now markes as unsuitable instead of estimated.
1607
1608 - callisto: Fixed a problem in the spline extraction which gave
1609 weird results if the signal was extracted from the first (and
1610 highest) slice (as a workaround extraction from the first
1611 slice has been forbidden)
1612
1613 - callisto: Fixed a bug regarding the use of the QE which doesn't
1614 effect the result because the default is used anyhow.
1615 (The bug was there since 14/07/2005)
1616
1617 - callisto: Changed the default for fgLoGainStartShift to -2.4
1618
1619 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1620 factors to be always 10 for all pixels as soon as the first
1621 calibration update has happend.
1622
1623 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1624 was off by more than one slice (which gives wrong values for
1625 pixels which have saturated the hi-gain) This was a problem
1626 mainly for timing studies, not so much for the automatic standard
1627 analysis. Also the values for the Spline have been changed slightly:
1628 + Digital Filter from 1.70 to 0.95
1629 + Spline from 1.39 to 1.30
1630 The numbers were sorted out by an extensive test in the
1631 test-database.
1632
1633 - callisto: Removed the tab showing the average calibrated arrival
1634 time. It never gave useful information.
1635
1636 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1637 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1638 and both were extracted because the hi-gain was above the
1639 LoGainSwitch.
1640
1641 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1642 lo-gain pulse position (after application of LoGainOffset, which
1643 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1644 have saturated and both were extracted because the hi-gain was above
1645 the LoGainSwitch.
1646
1647 - callisto: After extensive tests a new threshold level for determination
1648 of the pulse position has been found at 50phe. This is due to the
1649 fact that for lower pulses the arrival time changes its average
1650 behaviour dramatically. It tends to the average of the extraction
1651 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1652
1653 - callisto: Added two more plots to the calibration part. The average
1654 extracted signal and the average extracted arrival time as
1655 extracted by the signal extractor (This can help debugging problems
1656 because it doesn't involve a fit)
1657
1658 - star: changed the fit for the effective on time such that initial
1659 values are calculated automatically now instead of using build
1660 in values. This makes the fit more indepedant of the underlaying
1661 rates. With a test of ~350 sequences in the test database it could
1662 be shown that the new fit gives the same result +/-1sek.
1663 The highest deviation was +5s the lowest -10s. You can now control
1664 the bahaviour with two resource values:
1665 MHEffectiveOnTime.FistBin: 3
1666 MHEffectiveOnTime.NumEvents: 12000
1667 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1668 from the resulting gamma candidates
1669
1670 - star: The Center histogram in MHHillas is now by default displayed
1671 with the colz draw-option
1672
1673 - ganymed: now produces valid error codes if failed
1674
1675 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1676 with the option "hadronness" instead of "area" or "both" if
1677 you want to use both cuts. The hadronness cut includes a fixed
1678 cut in hadronness (index 8) and a fixed cut in size (index 9).
1679
1680 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1681 the M3Long of the anti source to be not properly evaluated
1682 (actually is was evaluated as a unique random number) in case
1683 of optimization with anti-theta cut switched on. This might have
1684 lead to improper, but not necessarily wrong, optimization results.
1685
1686 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1687 how to use random forest
1688
1689 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1690 ganymed_onoff.rc. Seems to be unintentional that they were different.
1691
1692 - sponde: Since the introduction of the possibility to define a
1693 normalization energy instead of using the integral the default
1694 was not using the integral anymore but a normalization energy of
1695 1GeV. It is now the integral again.
1696
1697 - sponde: Fixed a problem in the weighting which did not allow
1698 a MC slope of -1.
1699
1700
1701
1702 *** Version 0.9.6 (2006/05/24)
1703
1704 - general: changed the binning of the azimuthal profile of the camera
1705 such that it is aligned with the 60deg boundaries.
1706
1707 - merpp: better handling of problems with the TH, TD part of the
1708 CC-REPORT for files older than 200507190 and 200412210
1709 respectively
1710
1711 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1712
1713 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1714
1715 - callisto: if an arrival time is extracted outside the fadc range is
1716 was set to the boundary before. Now a random number is assigned
1717 instead to avoid unfortunate coincidences of arrival times just
1718 by this arbitrary value.
1719
1720 - callisto: added a new option to callisto.rc which allows
1721 to set the maximum arrival time difference allowed for the
1722 badpixel algorithm to determin whether a pixels belongs to a shower:
1723 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1724
1725 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1726 to 0.9 as suggested by Stefan due to a recent study on the fraction
1727 of pixels surviving the image cleaning
1728
1729 - callisto: switched off error in case of "pulse is too much to the left"
1730
1731 - callisto: The extraction window is not adapted anymore. This means that
1732 the pulse is extracted from the full range. The draw-back is that the
1733 background (pedestal) will become slightly higher. Switching on/off
1734 the PulsePosCheck in the callisto.rc only effects filling the
1735 histograms.
1736 WARNING: If the pulse is too much to the left data is calibrated!
1737 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1738 in the database to make sure that your data is valid!
1739
1740 - star: Show also the number of stars correlated correctly by the
1741 starguider
1742
1743 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1744 than one off-source region in wobble-mode. To use it add the following to
1745 your ganymed_wobble.rc:
1746 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1747 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1748 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1749 + Cut1.ThetaCut: None
1750 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1751
1752 - ganymed: in the case the latest report is older than a default (currently
1753 one minute) and the current report will be skip the starguider
1754 correction and calibration will be reset. The maximum age can be
1755 setup from ganymed.rc by (minutes):
1756 MPointingDevCalc.MaxAge: 1.5
1757
1758 - ganymed: A first implementation showing all size-bins for the theta-sq
1759 resp. alpha-plots in a single tab automatically
1760
1761
1762
1763 *** Version 0.9.5.1 (2006/05/05)
1764
1765 - general: Added a new option "zdiff" to the Makefile which runs
1766 "cvs diff" as "make diff" would do, but with compression
1767
1768 - general: accelerated MTFillMatrix (used for eample in all training
1769 and optimization macros) by skipping some obsolete calles in the
1770 eventloop the first and second loop could be accelerated by ~20%
1771
1772 - general: Added a missing feature in the MFilterList class which
1773 prevented MFEnergySlope from working correctly in trainenergy.C
1774
1775 - general: Accelerated the random forest training and usage a bit
1776
1777 - merpp: Adapted to new raw data file format version 6
1778
1779 - merpp: fixed a problem with reading the starguider reports
1780 after 6.3.2006
1781
1782 - callisto: At some times six pixels had to be exchanged manually in the
1783 data. If the pixels to be swaped are both not found, an error was raised
1784 and calibration was stopped. Now it is assumed they are intentially not
1785 mapped and the Error has been changed to a Warning.
1786
1787 - star: Added new image cleaning based on the arrival time of the shower.
1788 The new cleaning can be accessed using the parameter "Time" instead of
1789 the the old one (like "Absolute) in the star.rc-file.
1790 Recommended parameters:
1791 + MImgCleanStd.CleanLevel1: 8.2
1792 + MImgCleanStd.CleanLevel2: 5
1793 + MImgCleanStd.CleanRings: 2
1794 + MImgCleanStd.KeepSinglePixels: No
1795
1796 - star: Simplified the calculation of the effective on time. By letting
1797 the fit start in the third bin the result should become more stable.
1798 The fit quality is now ignored for the theta-plot which is not used
1799 in the analysis later. Still better pre-cut which, for example,
1800 remove events triggered by car-light (rate changing on a short
1801 time-scale) are missing.
1802
1803 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1804 for optimization (kWeakSource) which is suggested by the Berlin
1805 people for weak sources.
1806
1807 - macros: plotdb.C:
1808 + if no dataset and no time-interval is given only sequences with
1809 an effective on-time above five minutes are plotted anymore
1810 + added a new tab "RelTime" displaying the relative on-time
1811 (effective on-time divided by the observation time)
1812
1813 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1814 the optimization became a lot faster
1815
1816 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1817 To display them just delete the pads displayed on top.
1818
1819 - ganymed: fixed a bug which could cause strange behaviour in wobble
1820 mode if no starguider information was available due to an incorrect
1821 initialization of the starguider calibration
1822
1823 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1824 be changed from within the plot. It can also be setup from the
1825 resource file using:
1826 + MHDisp.fScaleMin: 0.325
1827 + MHDisp.fScaleMax: 0.475
1828
1829 - ganymed, showplot: Fixed a problem with the fit to the off-data
1830 (HistOff) which could cause a time lag or an inifinite loop.
1831 The bug did not effect the results at all.
1832
1833 - sponde: Added a new tab showing the effective collection area after
1834 trigger (including the software trigger)
1835
1836 - sponde: MMcSpectrumWeight has a new option which allows to define
1837 the scaling factor not by the integral of the events but at
1838 a defined energy:
1839 e.g. MMcSpectrumWeight.NormEnergy: 200
1840
1841 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1842 eventloops the loop could be accelerated by ~20%
1843
1844
1845
1846 *** Version 0.9.5 (2006/03/13)
1847
1848 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1849 and added the standard Disp-parametrization
1850
1851 - macros: added a new macro datacenter/macros/plotstat.C allowing
1852 to plot statistics about the data processing
1853
1854 - macros: added a new macro to plot the muon correction coefficients
1855 versus period (macros/plot/mucal.C)
1856
1857 - showplot: path inflation for ganymed files was broken
1858
1859 - callisto: Fixed an important bug. When the number of saturating pixels
1860 were calculated the bad pixel information already available from the
1861 calibration was ignored. This yields wrong values in case pixels
1862 are broken and saturate all the time or randomly.
1863
1864 - callisto: Updated Muon calibration constants. Spline data now also uses
1865 different values for different periods
1866
1867 - star: The time-evolution shown in the effective on-time plot now displays
1868 the axis range (if there are no holes it should be similar to the
1869 effective on-time)
1870
1871 - star: Added two new image parameters:
1872 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1873 the three pixels next to the center of gravity and the size
1874 + MNewImagePar.fConcCore: The ratio of the signals of all
1875 pixels inside or touching the ellipse and the size
1876
1877 - ganymed: now stops in requested source isn't found in catalog file
1878
1879 - ganymed: Many improvements to the phi-plot in wobble mode:
1880 + with a template the ideal background is displayed
1881 + a possible camera inhomogeneity is taken into account
1882 + the anti theta cut is better supported
1883 + the phi cut is automatically calculated from the theta cut
1884 See the examples in ganymed_wobble.rc for more details.
1885
1886 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1887 times the bin-width instead of the absolute energy
1888
1889 - ganymed: New cuts for on/off and wobble mode
1890
1891 - ganymed: The smearing of the False Source plot has been increased
1892 to 0.06
1893
1894 - ganymed: The starguider calibration can now be changed from the
1895 resource file.
1896 See the examples in ganymed*.rc for more details.
1897
1898 - ganymed: added a new option for on-/off-observations
1899 MJCut.RandomSourcePosition
1900 If switched on the distribution of observation time of the source
1901 position in the camera is calculated from the on-data and randomly
1902 applied with this distrbution to the off-data.
1903
1904 - ganymed: by skipping some obsolete calles in the eventloop the
1905 first and second loop could be accelerated by ~20%
1906
1907 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1908 position in the off-data randomly according to its distribution in the
1909 on-data.
1910
1911
1912
1913 *** Version 0.9.4.3 (2006/02/13)
1914
1915 - general: Fixed a bug in most of the programs which prevented the
1916 compile date in the startup message to be displayed
1917
1918 - general: Simplified program calls. The following abbreviations
1919 are now possible:
1920 showlog callisto 55599
1921 showplot signal 55599
1922 star 55599
1923 callisto 55999
1924 ganymed 2
1925 In this cases the corrsponding root-, log-, sequence- or dataset-
1926 filename is automatically compiled using the default datacenter
1927 paths ("/magic/*")
1928
1929 - general: Fixed a long outstanding bug which made axis tick marks
1930 disappear if MDataFormula was used (eg. abs(x))
1931
1932 - general: Updated MMath with new functions to calculate the results of
1933 a exponential, logarithmic and powerlaw fits analytically.
1934
1935 - general: Updated some macros with comments:
1936 + macros/optim/optimdisp.C
1937 + macros/optim/optimenergy.C
1938 + macros/optim/optimwobble.C:
1939
1940 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1941 files) now allows adding a pre-cut like in the optimization. E.g. this
1942 is useful to perform g/h-separation cuts before training the random
1943 forest.
1944
1945 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1946 correctly assigned in the raw data assignement table. A fix to correct
1947 the assignment tabel have been implemented.
1948
1949 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1950 by 90, 180 and 270 deg.
1951
1952 - general: the macro plotdb.C now allows to highlight sequences belonging
1953 to a datset. For more details see the descritions in the macro.
1954
1955 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1956 of the display, it gave wrong results espacially for big sizes.
1957 Now the embedded canvas should always have a ratio width/height=3/2.
1958 The "Size" options have been updated with values fitting the 3/2
1959 size ratio.
1960
1961 - RanForest:
1962 + Updated the random forest classes to support also the
1963 regression method implemented by Thomas H.
1964 + added new tutorial macro how to train the random forest
1965 for energy estimation (macros/optim/rfenergyest.C)
1966 + new classes to train the random forest (still in development)
1967 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1968 + new tutorial macros for random forest training in macros/train
1969 trainenergy.C, traindisp.C, trainseparation.C
1970
1971 - mars: now allows to setup a cut in the resource file mars.rc to choose
1972 the events to be displayed, eg:
1973 Cut.Condition: {0} && {1}
1974 Cut.0: MHillas.fSize>100
1975 Cut.1: MHillas.fSize<900
1976
1977 - merpp: Made aware of the new .rep format 200510250. This includes
1978 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1979 the discriminator thresholds (MCameraTD) and the disciminator
1980 delays (MCameraTD). All of them come with the CC report and are therefor
1981 written to the CC tree.
1982
1983 - callisto: fixed a bug in the calculation of the arrival times in
1984 the Digital Filter. They were all shifted by the same amount
1985 fHiGainFirst. This caused an offset in the order of the position of
1986 the left border of the extraction window in the times calculated
1987 from high-gain and from low-gain. The bug effected only the absolute
1988 arrival times. The bug was there since 30.1.2005.
1989
1990 - callisto: Changed the ExtractionWindow for the pulse position check
1991 such that the camera inhomogeneity becomes as less as possible and
1992 comparable to the pulso position check switched off. More details
1993 on the study will be given at our result web-page.
1994
1995 - ganymed: ganymed.rc, ganymed_onoff.rc:
1996 changed to new cuts trained with 1ES1218 and Crab-data
1997 for maximum sigma*log10(excess)
1998
1999 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
2000 a new option was implemented to estimate Disp (CalcDisp)
2001
2002 - ganymed: Implemented two new options which allow
2003 to overwrite the default path to search for the sequence files
2004 --ins=/magic/sequences
2005 and where to search for the image data
2006 --ind=/magic/data/star
2007
2008 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
2009 dx/dy from the resource file by
2010 MSrcPosCorrect.Dx
2011 MSrcPosCorrect.Dy
2012
2013 - ganymed: fixed reading the source catalog. Only as many chars
2014 as the requested source name had were compared (If a source
2015 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
2016 were requested it could happen that the coordinates of
2017 "1ES1218" were read) The source coordinates are now printed
2018 in addition to its name to the logging output.
2019
2020 - ganymed: changed the background fit in the case of a ThetaSq function
2021 from a polynomial to a exponential, this should give a big improvement
2022 for on-only analysis'
2023
2024 - ganymed/sponde: Calculation of the error of single size-/energy-
2025 bins now uses Li/Ma (5) instead of LiMa (17)
2026
2027 - sponde: Added a plot E^2*dN/dE
2028
2029 - sponde: The energy estimator plot should now show values like
2030 they are commonly used.
2031
2032 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
2033 (a powerlaw with cutoff didn't work before)
2034
2035
2036
2037 *** Version 0.9.4.2 (2005/10/01)
2038
2039 - general: added new tutorial macro macros/tutorials/threshold.C:
2040 how to calculate the threshold
2041
2042 - general: added a new game. Start it from the interpreter with
2043 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
2044 and MagicReversi)
2045
2046 - general: neighbor pixels in MGeoms are now sorted clockwise
2047
2048 - merpp: made aware of new format 20050829-0
2049
2050 - callisto: New scale factors from muon analysis, stored in new
2051 resource file resources/calibration.rc
2052
2053 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
2054 the eventloop if something went wrong. This is necessary for the
2055 automatic processing
2056
2057 - callisto: Implemented a new treatment for the time information
2058 developed by S.Ruegamer, this should give much better response than
2059 the old very primitive algorithm. This is especially important
2060 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
2061 treatment was buggy! As neighbor pixels to interpolate the
2062 arrival times always the pixels 0 to 5 were taken)
2063
2064 - callisto: In addition to the new treatment of arrival times the
2065 decision of the treatment whether a pixel contains shower
2066 information or not is used to improve the signal interpolation
2067 further. Previously interpolated pixels showed a non-zero signal
2068 do the peak searching signal extractors. Having a signal pixel
2069 beside raised the signal above the cleaning level. Thus the
2070 pixel survived cleaning to often but with a too low mean signal.
2071 By replacing empty pixels with a gaus (mean and rms from the
2072 corresponding Area entries in MPedPhotCam) this effect can
2073 be supressed.
2074
2075 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
2076 got lost when the events were stored by the calibration... fixed.
2077 (This was no problem for normal image cleaning because the pixel
2078 content was artificially set to 0 not surviving standard cleaning
2079 algorithm)
2080
2081 - callisto: Fixed a bug which caused the random and peak-search pedestal
2082 extracted with an extractor to be exchanged for the first (roughly)
2083 500 events (*Extractor and *ExtractorRndm).
2084 (They were simply exchanged in callisto.cc) This bug might have been
2085 introduced in Mars 0.9.4 when the order of calculation of the two
2086 types of pedestal in callisto got exchanged. The bug only effects
2087 the first seconds of data of each sequence.
2088
2089 - star: Taking the arrival time of Muons into account the calculation
2090 of the parameters could be made independant of the noise
2091 (pedestal rms). The dependance was due to the bias of the peak search
2092 extractor. Now only a ZA dependamcy is left which is not yet fully
2093 understood.
2094
2095 - ganymed: The sequences were still not sorted correctly in any case,
2096 because they were sorted by the full qualified path name. Now they
2097 are sorted by their sequence number.
2098
2099 - ganymed: new values for the spark-event-cut
2100
2101 - sponde: required missing MEnergyEst from ganymed.root... fixed.
2102
2103
2104
2105 *** Version 0.9.4.1 (2005/08/18)
2106
2107 - callisto: fixed some problems with the calibration in case of
2108 inteleaved events. Therefor the final and some intermediate
2109 fits are skipped which would take place on partly filled #
2110 histograms and gave wrong results or failed completely.
2111
2112 - callisto: If the intermediate finalization of the histograms
2113 calculating the mean charge of the calibration signal fails
2114 it is counted now and printed in PostProcess of MCalibCalcFromPast.
2115
2116 - ganymed: Fixed some bugs which caused problems in On-only mode.
2117 Still the false source plot doesn't give reasonable results.
2118
2119
2120
2121 *** Version 0.9.4 (2005/08/05)
2122
2123 - general: Fixed the ZA binning. It did not correctly fit the
2124 MC binning
2125
2126 - general: Added a class to correct for the missfocussing in
2127 April (MSrcPosCorrect)
2128
2129 - general: Random Forest energy estimator should now work properly
2130
2131 - general: MHCamera now displays the profiles in deg instead of mm
2132
2133 - general: MH::SetPalette offers a lot of new palettes
2134
2135 - general: MHillas - the case of CorrXY==0 is now handled properly
2136
2137 - general: implemented the possibility to change the line and
2138 marker style of a sky-grid drawn by MAstroCatalog
2139
2140 - general: Runs in sequences and datasets are now automatically
2141 ordered (it is assumed that the order of their filenames correctly
2142 represents the order of observations) to ensure correct reading
2143 of the subsystem data
2144
2145 - general: Runs cannot be added to a sequence twice anymore. Also
2146 Sequences cannot be added twice anymore to a dataset.
2147
2148 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
2149 It gave wrong results by 1./2pi
2150
2151 - showplot: got a new option to start a root interpreter, too
2152
2153 - mars: now displays a rough estimate of Disp and the third moment
2154
2155 - mars: now displays the event time MTime if available
2156
2157 - mars: show muon parameters graphically
2158
2159 - mars: now the file to open can be given as commandline
2160 argument
2161
2162 - merpp: Added support for new arehucas version >= 200507190
2163 implementing values for three temperature sensors in the
2164 counting house (MCameraAUX) and the name of the HV settings file
2165 (MCameraHV).
2166
2167 - merrp: Also fixed some problems with wrong versions numbers stated
2168 by arehucas and implemented some fixed for old versions (<200407070)
2169
2170 - callisto: MCalibrationHiLoCam can now be printed from its context
2171 menu, eg in the TBrowser
2172
2173 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2174 - 1.39 (MExtractTimeAndChargeSpline)
2175 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2176 This is important mainly for timing studies.
2177
2178 - callisto: Changed limits in MHCalibrationChargeCalc from
2179 - -100.125 to -98 (fgChargeHiGainFirst)
2180 - 1899.875 to 1902. (fgChargeHiGainLast)
2181 - -100.25 to -99 (fgChargeLoGainFirst)
2182 - 899.75 to 901. (fgChargeLoGainLast)
2183 Introduced new limits:
2184 - fgNumLoGainBlackoutLimit: 0.05
2185 - fgLoGainBlackoutLimit: 3.5
2186 - fgLoGainPickupLimit: 3.5
2187
2188 - callisto: The handling of automatic weights for the digital filter
2189 has been improved. There are now new calibration weights special
2190 for Monte Carlo calibrations.
2191
2192 - callisto: Updated Muon scale with latest results (1% difference
2193 for most data, 5% for Mar/Apr'05)
2194
2195 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2196 was saturated and the blackout-events in the low-gain exceed the
2197 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2198 This excludes those pixels which have a saturating high-gain
2199 channel, but the low-gain switch does not switch often enough
2200 to make the distribution reliable.
2201
2202 - callisto: fix a bug counting the number of saturated events. Up to now,
2203 the number of saturated slices was counted (which is one for a not too
2204 high number), but for some (pathological) pixels, many more slices
2205 saturated and produced wrong limits.
2206
2207 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2208 + MCalibrationRelTimeCam.CheckFitResults: Yes
2209 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2210 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2211 + MCalibrationRelTimeCam.CheckOscillations: Yes
2212
2213 - callisto: introduce max. number of events for intercalibration,
2214 the rest gets skipped. Default: 4096
2215 The calibration causes too many un-reliable pixels if more
2216 than about 5000 events are treated (@500 Hz) because of the
2217 mode hopping of the VCSels. However, in the past, some
2218 calibration runs have been taken (erroneously) with more
2219 than 5000 events, especially the intensity scans where
2220 a good precision is needed.
2221
2222 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2223 photo-electrons for the spline extractor by 1-2% (correctly).
2224
2225 - callisto: The intercalibration is now done using a full f-factor
2226 method instead of a simple update. This makes things slower but
2227 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2228 changes.
2229
2230 - callisto: MPedestalY3 now uses the same extraction range as the data
2231 as calculated by MPedestalY2
2232
2233 - callisto: A check of the fraction of allowed unsuitable (10%) and
2234 unreliable (30%) pixels has been addded when the conversion is
2235 calculated from interleaved events
2236
2237 - star: fixed a bug which caused MEffectiveOnTime containers not to
2238 be written. In the worst case they were skipped almost all, in the
2239 best case they were all ok. It depends on how often the new value
2240 was assigned just with an event which was skipped later by another
2241 task
2242
2243 - star: new histograms MHPointing and MHRate
2244
2245 - star: New tab (Currents) displaying the time evolution of the mean
2246 DC currents
2247
2248 - star: New tab (MeanRms) displaying the time volution of the mean
2249 Pedestal Rms
2250
2251 - star: Output now contains MReportStarguider
2252
2253 - star: Improved muon analysis. Due to the absense of a constant
2254 for the gaus fit for arc width and the fact that the arcwidth
2255 plot was a histogram instead of a profile the resulting psf
2256 became pedestal rms dependant
2257
2258 - ganymed: added new plot (MHPhi) for wobble mode as described in
2259 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2260
2261 - ganymed: corrects now (correctly?) for the misspointing in
2262 May/April 05
2263
2264 - ganymed: Two new default templates for ganymed.rc are avilable:
2265 ganymed_onoff.rc and ganymed_wobble.rc
2266
2267 - ganymed: The first version of MFMagicCuts has been released
2268
2269 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2270
2271 - ganymed, sponde: There are two new options to determin the number
2272 of bins for the signal region (NumBinsSignal) and the number of
2273 total bins (NumBinsTotal) in the MHThetaSq histogram
2274
2275 - ganymed: optimized palettes for MHDisp
2276
2277 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2278 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2279 sqrt(2) to large
2280
2281 - ganymed: The false source plot (MHDisp) is now based on Disp
2282 and a background model determined in the first loop is
2283 subtracted
2284
2285 - ganymed: MFMagicCuts are now available in the cvs. The correct
2286 solution for the disp ambiguity problem is now calculated using
2287 the third moment. The third moment cut therefor is skipped.
2288
2289 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2290 already determined by the third moment along the major axis and
2291 so its actual sign is aligned along the major axis of the shower.
2292
2293 - ganymed: If starguider data is available it is taken into account
2294 when calculating the source position. This is especially important
2295 for wobble data at high zenith angles and culmination data.
2296
2297 - ganymed: If available the starguider data is taken into account as
2298 good as it is possible without a starguider calibration. To switch
2299 it off add
2300 MPointingDevCalc.MaxAbsDev: -1
2301 to your ganymed.rc
2302
2303 - sponde: the zenith angle distribution is now weighted instead of
2304 choosen by default. This gurantees higher statistics in the highest
2305 and lowest energy bins. To switch this behaviour off use...
2306
2307 - sponde: now automatically displays the energy threshold
2308
2309
2310
2311 *** Version 0.9.3 (2005/06/03)
2312
2313 - general: MMcEvt now derived from MMcEvtBasic which should
2314 have no influence on compatibility with older camera files
2315
2316 - general: Implemented a new option to MReadReports which allows
2317 to force reading of the first event of some trees (eg. Drive-tree)
2318 before any other tree.
2319
2320 - general: Made a fix to MPointingPosCalc which assumes that the
2321 run-type is real-data if Process is called before ReInit, such
2322 that also the very first Drive-events in a run are treated
2323 correctly.
2324
2325 - shoplot now displays the filename in the title bar of the window
2326
2327 - merpp: new options: --auto-time-start --auto-time-stop which
2328 allow to cut updating with slow-control at the start- or
2329 (previousle --auto-time only allowed: and) stop-time of
2330 the run stored in the runheader.
2331
2332 - callisto: changed default of fgFallTimeHiGain in
2333 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2334 already set as default in callisto_Dec04Jan05.rc
2335
2336 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2337 now changes the filename for new weights automatically for
2338 cosmics, MC and for different calibration colors.
2339
2340 - callisto: a problem with the order of some code cause the
2341 name of the weights file in MPedestalY2 to be ignored.
2342 Wrongly the calibration_UV weights were used instead
2343 of the cosmics weights set in callisto.rc.
2344
2345 - callisto: should allow ct1 pulser data when the color is
2346 explicitly set also for pretty new runs
2347
2348 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2349 to introduce an additional scale factor (should be around 1)
2350 to adapt for slight deviations in different extractors from
2351 the MC calibration. For MC calibrations the scale factor
2352 is fixed to 1
2353
2354 - callisto: MFCosmics should handle very high signals a bit
2355 more accurate now
2356
2357 - callisto: when calculating the mean pedestal rms for different
2358 pixel sizes or sectors also kUnsuitableEvt is now taken into
2359 account - not only kUnsuitableRun
2360
2361 - callisto: '-raw' option is now the default
2362
2363 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2364 This has the advantage that mean values in the calibration (eg
2365 arrival times) are calculated more accuratly.
2366
2367 - callisto: In the resource file callisto_Dec04Jan05.rc
2368 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2369
2370 - callisto: new Hi-/Lo-Gain intercalibration constants
2371 hilocalib_sp1.root and hilocalib_sp1_mc.root
2372
2373 - callisto: changed default for MJPedestalY2.MaxEvents
2374 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2375
2376 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2377 has changed from 9.0 to 6.0. This is necessary to exclude two very
2378 ringing pixels in September which - when kept - destroy the image
2379 cleaning around them (Markus G.)
2380
2381 - callisto: (!) The Muon analysis of all data taken so far has
2382 suggested that different extractors give slightly different
2383 absolute results after calibration, due to there different
2384 handling of the calibration- and cosmics pulse shape. Although
2385 the over all calibration seems to be a bit to pesimistic (or
2386 the MC seems to be a little bit - 3-5% - too much attenuated).
2387 There for correction factors have been introduced which correct
2388 the calibration constants by
2389 0.956937799 for Digital Filter (callisto.rc)
2390 and
2391 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2392 calibration. The main advantage is, that both data types can
2393 be easily analysed together and compared to the same MC sample.
2394 The factors are choosen such, that the reference is now a
2395 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2396
2397 - star: fixed a bug which caused the first bin of the histograms
2398 vs time to disapear in PostProcess. This gave wrong results
2399 on the screen. The output and all following programs not
2400 directly accessing the histograms haven't been affected
2401
2402 - star, ganymed: Made sure that always the first Drive-tree event
2403 is read and Processed before the first data event was read.
2404
2405 - ganymed: implemented the possibility to replace the standard
2406 false source plot with a different one. For example: If
2407 you want to use a Disp based FS plot use the resource:
2408 NameHistFS: MHDisp
2409 For details about the requirements of these plots look
2410 at the corresponding classes
2411
2412 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2413 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2414 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2415 case MAlphaFitter is setup correctly. For On-Only optimization
2416 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2417 RunOn() instead of Run(). For energy estimation MJOptimize
2418 has been replaced by MJOptimizeEnergy
2419
2420 - sponde: The input MC spectrum can now be weighted to fake a
2421 different spectrum. This is done via MMcSpectrumWeight. For
2422 more details see the class description and sponde.rc
2423
2424 - sponde: The paremeter comparsion plots are not scaled by
2425 their entries anymore. Instead the MC plot is scaled by using
2426 the result spectrum of the analysis. If the input MC spectrum
2427 and the result spectrum has different slopes the absolut
2428 normalization is normally wrong.
2429
2430
2431
2432 *** Version 0.9.2 (2005/05/20)
2433
2434 - general: Changed the default paths for calibrated data and image
2435 files. (The implemented access to these files doesn't yet exist)
2436
2437 - general: support for MRunIter has been removed from the job classes
2438 (use the setter functions of MSeqeunce instead)
2439
2440 - general: ProcessFile has been renamed to Process in all job classes,
2441 because ProcessFile is missleading
2442
2443 - general: The storage of the palette in MHCamera is now possible
2444
2445 - general: new bits describing unsuitable and unreliable pixels have
2446 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2447 kDeadPedestalRms, kFluctuatingArrivalTimes
2448
2449 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2450 versions newer than V200404070
2451
2452 - general: support for cc file versions newer than V200504130. Added
2453 support for active loads (MCameraActiveLoad) and central pixel
2454 (MCameraCentralPixel)
2455
2456 - general: added new histograms for image parameters versus size
2457 (MHVsSize)
2458
2459 - general: The eventloop now automatically calls PrintStatistics
2460
2461 - Status Display: Improved support for printing:
2462 + A default can now be set in .rootrc (for more details see
2463 MStatusDisplay::PrintPS)
2464 + A print dialog is opened so that printer and command line
2465 can be canged
2466
2467 - showlog: improved such that it handles different verbosity levels
2468 more accurate now. This mean you can suppress output when
2469 using showlog.
2470
2471 - showplot: improved
2472 + The new graphics formats have been implemented
2473 (pdf, svg, png, jpg and xpm)
2474 + Implemented an interface for printing. Because you can change
2475 the printing command from the command line you can use all
2476 the nice postscript tool. To print a booklet for example call:
2477 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2478 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2479 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2480
2481 - callisto: fixed a bug in the recognition of the calibration bit
2482 pattern. Concerns only intensity calibration. (The strength of the
2483 intensity has been updated in some cases)
2484
2485 - callisto: add a filter against PIN Diode events when running over
2486 calibration runs since some of the recent calibration runs have
2487 been taken with Pin Diode.
2488
2489 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2490 39943, 44833 in the calibration (MCalibColorSet)
2491
2492 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2493 been set to 1e-18 in callisto_Dec04_Jan05.rc
2494
2495 - callisto: in callisto_Dec04Jan05.rc: set value for
2496 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2497 statistics for the calculation of the mean pulse time
2498 of the cosmisc
2499
2500 - callisto: the charge limit in the calibration has been raised
2501 from 2.5 to 4.5
2502
2503 - callisto: new setup read from callisto.rc
2504 + MCalibCalcFromPast.fNumEventsDump
2505 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2506 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2507
2508 - callisto: MExtractTimeAndChargeSpline extractor:
2509 + The integration ranges were shifted by 0.2 FADC slices to the right.
2510 + unreliable handling of floating point values caused different
2511 results on different platform or with different compiler options:
2512 The new algorithm is numerically exact and more accurate because
2513 it doesn't calculate the integration position by multiple times
2514 adding the step-size (which results in numerical uncertanties
2515 exspecially if multiplied with large numbers)
2516 + A lot of fixes have been introduced which effects integrating the
2517 spline at the edges of the valid range. In this case any memory
2518 was randomly accessed. This behaviour can be tested replacing
2519 all MArrayF by TArrayF which perform a range check (but of course
2520 they are a lot slower)
2521 ! No result obtained with the Spline before can be trusted! Due to
2522 random memory access it might by completely random!
2523
2524 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2525 + extraction range in the high gain to 4.
2526 + weights file to cosmics_weights46.dat
2527
2528 - callisto:
2529 + introduce the check for fluctuating arrival times.
2530 + set charge limit to from 2.5 to 4.5
2531 + introduce asymmetric exclusion due to "deviating number of phes":
2532 Default: -9.0 +4.5
2533 + make deviating number of phes unsuitable (see David's findings).
2534
2535 - callisto: fixed the display of unsuitable pixels. The old change
2536 to a real profile in MHCamera broke it.
2537
2538 - callisto: The cosmics filter is used in MJCalibration now
2539 independant of the pulser color (formaly it was used only for
2540 CT1-pulser data). The threshold of number of max empty pixels
2541 has been raised from 2% to 5% in MJCalibration. The maximum
2542 fraction of rejected event is 50% otherwise the calibration has
2543 failed. The filter now ignores unsuitable pixels.
2544 Setup the filter from callisto.rc using "ContCosmics"
2545 (see MFCosmics::ReadEnv)
2546
2547 - callisto: changed default for fgOffsetFromLogain back
2548 from -2.8 to -1.8 in digital filter.
2549
2550 - callisto: for the common extractors
2551 + MExtractFixedWindow
2552 * MExtractTimeAndChargeSlidingWindow
2553 * MExtractTimeAndChargeSpline
2554 * MExtractTimeAndChargeDigitalFilter
2555 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2556 and fResolutionPerPheLoGain
2557
2558 - callisto: Updated the hi-/lo-gain intercalibration constants
2559 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2560 hilocalib_df6.root
2561
2562 - callisto: The default lo-gain extraction window for the
2563 MExtractTimeAndChargeSlidingWindow extractor has been increased
2564 from 6 to 8 to take the stretch of the pusle into account
2565
2566 - callisto (!!!): fixed an important bug in the setting of the
2567 incoming pedestal pointer to the signal extractor extracting
2568 pedestals. This bug caused the pedestals not to be subtracted
2569 correctly in the calibration afterwards. The effect was about 10%
2570 too high conversion factors for the digital filter and the spline
2571 and more than 40% for the sliding window.
2572 The bug existed since end of February! (Markus G.)
2573
2574 - star: added muon support to star. A new tab "MHMuonPar" is
2575 displayed. The lower right plot is an estimate of the point spread
2576 function. A reference value is displayed. To get the real PSF
2577 you must compare with MC. The setup for the muon analysis
2578 is done in star.rc. More informations can be found in
2579 MHSingleMuon and MHCalibParCalc
2580
2581 - star: The weather data is now displayed in star
2582
2583 - star: MEventRateCalc handles the calculation of the event rate more
2584 accurate now in case of the start of a new run inside a sequence
2585
2586 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2587 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2588 changed only minimally
2589
2590 - ganymed: (MJCut and MJOptimize) now displayes the number of
2591 excess events versus size. The energy estimation is done in
2592 MJSpectrum (sponde)
2593
2594 - ganymed: got support for using other variables than Alpha, eg. Theta.
2595 Therefor you need a class deriving from MHAlpha which supports
2596 this variable (one is already existing: MHTheta, which is now the
2597 default in ganymed). It is setup through ganymed.rc
2598
2599 - added a full featured spectrum program (sponde) which reads
2600 ganymed output and monte carlos and compiles a spectrum
2601
2602
2603
2604 *** Version 0.9.1 (2005/04/14)
2605
2606 - Fix bug on the arrival time reconstruction when using Digital
2607 Filter (in some marginal cases (10%) times were reconstructed shifted
2608 by 0.2 slices)
2609
2610 - all executables now return 2 where in previous versions -1 has
2611 been returned (gave problems with shell-scripts)
2612
2613 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2614 also done with a intercalibration input file
2615
2616 - a bug in the time fine adjustment of the digital filter has been fixed
2617
2618 - a lot of small fixes to calling TPad::Divide with a margin==0
2619
2620 - MStatusDisplay now shows the memory usage
2621
2622 - added a memory leak statistic after the eventloop
2623
2624 - MHadronness replaced by MParameterD
2625
2626 - MEnergyEst replaced by MParameterD
2627
2628 - wobble mode can now be switched on from the data-set
2629
2630 - switched on bad pixel detection for a pedestal level
2631 which is more than 5 times the variance
2632
2633 - Fixed default paths to be correct for the new data center
2634
2635 - Fixed handling of drive data. The pointing position in now
2636 copied to MPointingPos inside star for real and MC events
2637
2638 - made sure, that the sequences in a dataset are sorted by
2639 their number to ensure the correct synchronization
2640
2641 - added all resource files necessary to handle spline extraction
2642 of signal for the late 2004 and the early 2005 data
2643
2644 - update the reference lines for the december data
2645
2646 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2647 This is important for the Dec. and Jan. data where the calibration
2648 pulse position changes much.
2649
2650 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2651 filter. This corrects only an defective extraction of the MC at
2652 low-gain signals lower than 90 phes.
2653
2654 - fixed some slowdown in calibrating data with interleaved events from
2655 Jan and Dec. As a workaround made the pretty palette the default.
2656 The inverse Deep Blue Sea has a bug which slows down long calibration
2657 runs a lot.
2658
2659 - implemented new values from new starguider report as defined
2660 in TDAS00-07 V7.1 (eg SkyBrighness)
2661
2662 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2663 in starguider report (If you merpp the same reports with this version
2664 you'll get the correct units (arcmin) but a different result
2665 than with old versions (wrong units))
2666
2667 - Now the status display can also write PNG, JPEG and XPM (other file
2668 formats are still unsupported by root)
2669
2670 - added a lot of scripts and macros in directory datacenter used
2671 for automatic processing
2672
2673
2674
2675 *** Version 0.9 (2005/03/23)
2676
2677 - Calibration is now done autmatically into photo-electrons like
2678 decided by the Collaboration Board
2679
2680 - Reference lines in the display can be read from resource file
2681
2682 - Interlaced calibration events can be handled by callisto
2683
2684 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2685 and applied in callisto.
2686
2687 - class MJCalibTest can be called by callisto
2688
2689 - callisto can now run with three data types: rawdata, rootdata, MC
2690
2691 - added two classes mreport/MReportStarguider.cc and
2692 mreport/MReportStarguider.h for implementing starguider-data
2693
2694 - the output of merpp-update now contains starguider information:
2695 MReportStarguider and MTimeStarguider
2696
2697 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2698 values were lower than they should. This was more visible for high
2699 energy (Size) events.
2700
2701 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2702
2703 - added a new loop to callisto to support the correct extraction of
2704 the pedestal and pedestal rms through the signal extractor
2705
2706 - added class to perform fourier tranformation of a hexagonal structure
2707 (MHexagonalFT)
2708
2709 - added class to perform fourier tranformation of a hexagonal structure
2710 in a tasklist (MHexagonalFTCalc) example: hft.C
2711
2712 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2713 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2714 small pixels, example: extendcam.C
2715
2716 - added possibility to write data to memory (TTree) using MWriteRootFile
2717
2718 - added possibility to read a TTree stored only in memory by MReadTree
2719
2720 - new classes to deal with the interleaved calibration events:
2721 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2722
2723 - implemented filters to callisto to skip calibration events
2724
2725 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2726 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2727 the slices by statistics
2728 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2729 signal extractor without randomization
2730 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2731 with the signal extractor with randomization (extraction window is
2732 randomly fixed)
2733 The three kind of pedestal is not yet implemented (for speed reasons) as
2734 long as nobody really needs it:
2735 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2736 extracted with the signal extractor with randomization
2737
2738 - callisto now finds the pulse position in the data automatically
2739
2740 - implemented data reduction in calibrated data by reducing the precision
2741 of the stored floating point values (pedestal, rms and signal) to
2742 roughly 0.5%
2743
2744 - fixed showplot to make file format conversion (eg. converting a
2745 status display stored in a root file into a postscript file) in
2746 batch mode possible:
2747 showplot -b --save-as-ps[=outfile.ps] infile.root
2748
2749 - Allow class names as part of filter rules, eg
2750 (MFSupercuts) && (MHillas.fSize>100)
2751
2752 - fixed a lot of stuff to allow all programs to process MonteCarlo
2753 camera files.
2754
2755 - enhanced possibility to debug reading of resource file
2756
2757 - MDataChain should handle priorities of operator more
2758 accurate now
2759
2760 - completely revised the container in which the signal is stored
2761 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2762 * the new implementation is faster and
2763 * needs less storage space
2764
2765 - FIRST version which can process Monte Carlos through the
2766 whole chain of programs (callisto, star, etc)
2767
2768 - implemented new image parameters for the border length of
2769 the shower image (MNewImagePar2)
2770
2771 - implemented wobble-mode in ganymed
2772
2773 - new class (MJOptimize) taking care of all optimization processes
2774
2775
2776
2777 *** Version 0.8.6 (2004/10/05)
2778
2779 - New combined signal and time extractor
2780 MExtractTimeAndChargeDigitalFilter
2781
2782 - The Report for the trigger section in the CC run summary has been
2783 updated, and now the IPRs (Individual Pixel Rates) are available.
2784
2785 - new macros for database interaction: filldotrun.C, filldotrbk.C
2786
2787 - added new program which can convert colored output which was redirected
2788 into a file back into colored text (for example to display it with
2789 more): showlog
2790
2791 - added new program to display an MStatusArray of plots (stored with
2792 MStatusDisplay) from a file: showplot
2793
2794 - Added support for Sequences (MSequence). Sequences are blocks of run
2795 files containing the same calibration and belonging to the same
2796 source
2797
2798 - Added a new task (MTaskEnv) which can be used in setup files to switch
2799 between different tasks (for example to choose a signal extractor)
2800
2801 - Implemented automatic file splitting in MWriteRootFile
2802
2803 - After image cleaning an island index is assigned to all used pixels.
2804 The index corresponds to the order of the islands in size.
2805
2806 - added a cleaning which takes signal height _and_ arrival time into
2807 account: probability cleaning (for more details see MImgCleanStd)
2808
2809 - added a cleaning which takes takes the absolute number of photons
2810 times the area ratio as cleaning level
2811 (for more details see MImgCleanStd)
2812
2813 - Changed calculation of image parameters such, that it can be done
2814 for all used pixels or the pixels with a defined island index only
2815
2816 - implemented new image parameters displaying the number of islands,
2817 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2818
2819 - event display in executable changed to support also calibrated files
2820 (done with MJCalibrateSignal)
2821
2822 - added program doing the calibration and the signal extraction
2823 and signal calibration: callisto Most part of the setup is done
2824 by a resource file: callisto.rc
2825
2826 - implemented support for pixels with negative IDs (Raw file format
2827 version 4)
2828
2829 - implemented an new option in merpp (--auto-time) to get the time
2830 range for cc and/or caco data from the run header of the raw data
2831
2832 - New star-program (star and MJStar). Taking calibrated data from
2833 callisto/MJCalibrateSignal as input. The setup is done through
2834 a resource file: star.rc
2835
2836 - Added possibility to setup the eventloop in the mars-executable
2837 Camera Display by a resource file: mars.rc
2838
2839 - The the mars-executable Camera Display can now also read
2840 calibrated data files written by callisto/MJCalibrateSignal
2841
2842 - Added a new class which can calculate the source position in
2843 the camera from a pointing model known to be correct and
2844 the pointing model used for observations (MSrcPosFromModel)
2845
2846 - added a new version of the class calculating the effective on-time
2847 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2848 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2849 MHTimeDiffTheta.
2850
2851 - added the possibility to count how often a signal is above (or
2852 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2853 can replace MHTriggerLvl0)
2854
2855 - added ore convinient ways to set the axis-titles of your histograms
2856 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2857 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2858
2859
2860
2861 *** Version 0.8.5 (2004/08/06)
2862
2863 - new Signal Extractors: MExtractFixedWindowSpline
2864 and MExtractAmplitudeSpline
2865
2866 - implementes interleave in merpp to be able to merpp parts of a file
2867
2868 - implemented force-functionality to merpp
2869
2870 - star display to display star catalogs (MAstroCatalog)
2871
2872 - star display to 'mirror' stars to the camera (MAstroCamera)
2873
2874 - implemented a new cleaning option which allows cleaning scaled with
2875 the real ratio of the rms depending on the pixel size, not only the
2876 square root of the pixelsize (MImgCleanStd, MCameraData)
2877
2878 - removed obsolete MBlind* classes
2879
2880 - Signal extractor taking the AB flag into account implemented (this makes
2881 an odd number of slices for signal extraction possible
2882 (MExtractSignalABcorr)
2883
2884 - implemented a class extracting the pedestal from the raw-data (events)
2885 itself using empty lo-gain (MpedCalcFromLoGain)
2886
2887 - Added mean values to MPedPhotCam
2888
2889 - Added Makefile for Darwin (this OS is NOT officially supported!)
2890
2891
2892
2893 *** Version 0.8.4 (2004/04/19)
2894
2895 - new fast arrival time extractor using cubic splines:
2896 MExtractTimeFastSpline
2897
2898 - implementes multi-argument support in MDataChain
2899 ("pow(a, b)")
2900
2901 - implemented double reference support in MDataChain
2902 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2903
2904 - added support in MF for expressiond like
2905 "MHillas.fWidth<2*<MHillas.fLength"
2906
2907 - MDataChain is now able to support variables like [0], [1], ...
2908 which can be used in fit functions as parameters. The interface
2909 is implemented through the new virtual function
2910 MParContainer::SetVariables
2911
2912 - added new class MArrivalTimeCam/MArrivalTimePix:
2913 Storage containers to hold the ArrivalTime of the camera/pixel
2914
2915 - added new classes for the calibration of relative arrival times:
2916 MCalibrationRelTimePix and MCalibrationRelTimeCam
2917
2918 - added new classes to extract the signal of the blind pixel and the
2919 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2920
2921 - added new classes for the bad-pixels treatment (MBadPixels*)
2922 which are more powerfull than the old ones (MBlindPixel*)
2923 and will replace them.
2924
2925 - added filter against cosmics: MFCosmics
2926
2927 - added new class MArrivalTimeCalc2:
2928 Calculates the arrival time as the signal weighted mean of the time
2929 slices in the maximum window
2930
2931 - added a new macro call pointspreadfucntion.C that fits with a 2D
2932 gaussian the DC spot for an star. It gives you the RMS of
2933 the PSF and the center of the star, very useful for misspointing
2934 studies.
2935
2936 - added support for multi-telescope camera files. Added classes
2937 MStereoCalc and MStereoPar, classes to calculate and store shower
2938 parameters calculated from the data of two telescopes, for the MC
2939 studies regarding the MAGIC clone.
2940
2941 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2942 MC data calibrated in photons instead of ADC counts.
2943
2944 - added three macros to show the calibration and analysis chain of
2945 MC data. The macro starmc.C does both calibration and analysis, producing
2946 an output containing Hillas parameters for each event. The macro
2947 mccalibrate.C does just the calibration and writes out a file containing
2948 pixel information in photons instead of FADC data. The macro starmc2.C
2949 reads in such a file and produces an output with Hillas parameters.
2950
2951 - added MPedPhotCalc to compute pedestals in units of photons, see
2952 macro pedphotcalc.C
2953
2954 - added all class to perform the calibration, see macro calibration.C
2955
2956 - added class MFFT to perform Fast Fourier Transforms
2957
2958 - added class MSimulatedAnnealing to perform simulated annealing
2959 minimizations
2960
2961 - added new macro bootcampstandardanalysis.C which holds the skeleton
2962 of the analysis chain discussed in the december bootcamp.
2963
2964 - added support for DAQ raw data file format V2
2965
2966 - implemented an arbitrary time stamp for the events from raw-data
2967 files with file version<3. It is calculated from the run number,
2968 the date of start and the FADC clock tick from the first module
2969
2970 - implemented the correct decoding of the event time-stamp
2971 coming from the DAQ for raw-data files with file-version>2
2972
2973 - added a new classes storing the pedestals in units of photons:
2974 MPedPhotPix, MPedPhotCam
2975
2976 - added support for DC current files from the camera control
2977
2978 - added support for start- and stop-time when merpping report files
2979
2980 - added MReportCC storing the weather data from the CC-REPORT
2981
2982 - added class to fill trainings and test matrices (MTFillMatrix)
2983
2984 - added a filter performing a software trigger (MFSoftwareTrigger)
2985
2986 - Added classes to perform parts of the standard analysis (Jobs):
2987 + MJPedestals
2988 + MJCalibration
2989 + MJExtractSignal
2990 Note: All of them are preliminary!
2991
2992 - Added Iterator to iterate over files giving only the run-number
2993
2994 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2995 the evolution of a sector vs time
2996
2997
2998
2999 *** Version 0.8.3 (2003/12/05)
3000
3001 - adapted Random Forest classes to allow the use with MC
3002 multi-telescope files which can be produced with the coming
3003 camera version 0.7.
3004
3005 - added classes to read and interprete central control report files
3006 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
3007
3008 - enhanced merpp (the executable) to support .raw and .rep files.
3009
3010 - added classes for light calibration (MCalibration* and
3011 MHCalibration*) by Markus Gaug. Further work has to be and will
3012 be done soon.
3013
3014 - Added a preliminary 'synchronizer' (MReadReports) which will
3015 replace MReadMarsFile as soon as it is finished.
3016
3017 - Added a tutorial macro demonstrating how report files are merpped
3018 and how they can be read from the root file in the correct order
3019 of time (readrep.C)
3020
3021 - Added a generalized histogram (similar to MH3) called MVsTime
3022 which allows to plot variables (or rules - MDataChain - of
3023 variables) vs time. For an example have a look at tempvstime.C.
3024
3025 - Changed the name of the event trees:
3026 + Events --> Events
3027 + PedEvents --> Pedestals
3028 + CalEvents --> Calibration
3029
3030 - changed name of MTime in the event trees from MRawEvtTime to MTime
3031
3032 - added displaying the sector indices to the mars event display
3033
3034 - Magic Online Analysis (MOnA) implemented in a first version
3035 (see mona.cc, MOnlineDump and MOnlineDisplay)
3036
3037 - added classes to calculate event rate
3038 (preliminary: MEventRateCalc, MEventRate)
3039
3040 - added new executable 'readdaq' to read *.raw files from the DAQ directly
3041
3042 - added classes dealing with the telescope pointing position (MPointing*)
3043
3044 - implemented the 'final' Mars time stamp based on some experiences with
3045 the new 'Synchonizer'
3046
3047
3048
3049 *** Version 0.8.2 (2003/11/10)
3050
3051 - accelerated standard analysis by a factor of 6-8 ...
3052 + doing precalculations in MGeomCam for the pixel area ratio
3053 + creating a look up table for the single pixels in MCerPhotEvt
3054
3055 - added task to calculates weights in case you want to 'change'
3056 the energy spectrum of a monte carlo file
3057 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
3058
3059 - added a new executable star which implements the
3060 star.C macro as precompiled executable. Currently a flexible
3061 setup is not possible, but a 'input card' setup will follow.
3062
3063 - Starting to implement Multi-Telescope-Support based on the
3064 upcomming camera version 0.7. The base for a general support
3065 is implemented and the star-functionality is proven to work.
3066
3067 - Replaced Event-Display in and Camera-Display in the Mars GUI
3068 executable by a more convinient display base on MStatusDisplay.
3069
3070 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
3071
3072
3073
3074 *** Version 0.8.1 (2003/10/20)
3075
3076 - added signal subtraction for pure on data by means of fitting
3077 the background in the off region or by performing a combined
3078 signal/background fit. Provides necessary histograms for
3079 obtaining energy spectra and a light curve.
3080
3081 - added classes to perform and study the selection of the
3082 2nd Level Trigger on MC data (example in triglvl2.C macro)
3083
3084 - added pedestal calculation
3085
3086 - implemented "democratic cleaning" (tail cut value proportional
3087 to pixel area) according to Wolfgang's suggestion.
3088
3089 - added Sigmabar treatment (calculation and basic histogramming)
3090
3091 - added basic routines to apply padding
3092
3093 - added first implementation of MARS-based source visibility plotter
3094 (needs to be linked against slalib, preliminary version)
3095
3096 - enhanced functionality of data chains: random numbers, conversion
3097 functions and access to MHMatrix objects
3098
3099 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
3100 numbers under certain circumstances (runs with 0 events included)
3101
3102 - fixed a bug in the general filter MF (didn't work on some systems
3103 at all)
3104
3105 - fixed a bug in chaining files, which caused the analysis to crash or
3106 ignore files
3107
3108 - implemented more geometry classes describing the parameters used
3109 to simulate the PMT camera
3110
3111 - added new Monte Carlo classes containing the setup of the different
3112 programs in the MC chain.
3113
3114 - added a (preliminary) general task to evaluate chi-square of a given
3115 parameter in an eventloop.
3116
3117 - first implementation of a container describing the observatory
3118 location (Long, Lat, etc)
3119
3120 - added Random Forest - method for g/h-separation
3121
3122 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
3123 (this means, that it is compiling, but not yet fully tested)
3124
3125 - added a new status display which can show the present status
3126 of histograms while an eventloop is running (MStatusDisplay,
3127 an example can be found at status.C)
3128
3129 - reorganized directories:
3130 classes describing the image --> mimage
3131 classes containing Monte Carlo Histograms --> mhistmc
3132 classes for Random Forest method --> mranforest
3133
3134 - added (event-)weights to fill histograms
3135
3136 - colors in logging output to screen
3137
3138 - changes to the Image Parameter declaration:
3139 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
3140 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
3141 + MHillasExt now derives from MParContainer instead of MHillas
3142 --> Files written with the old definition are more or less unreadable
3143
3144 - reading of reflector files
3145
3146 - display data from reflector files in the camera
3147
3148 - implemented currents (and display them in the camera)
3149
3150 - logarithmic scale in camera
3151
3152 - added class to iterate through directory contents (MDirIter)
3153
3154
3155
3156 *** Version 0.8 (2002/11/18)
3157
3158 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
3159
3160 - corrected 48(!) wrong entries in the Next Neighbor table of the
3161 Magic Camera (all in the inner part of the outer ring, mostly
3162 missing a single NN)
3163
3164 - Fixed a bug in the table describing the Next Neighbours of the
3165 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
3166 have any neighbour)
3167
3168 - changed trigrate.C: now it calculates the pure NSB triggers from
3169 a camera file (generated with no showers), so there is no need
3170 to introduce them by hand in the BgR array (for more details
3171 please ask Abelardo)
3172
3173 - added MHHadronness (and MHadronness) as a general facility to evaluate
3174 the quality of a gamma-hadron seperation method
3175
3176 - changed MWriteAsciiFile to accept rules (MDataChain)
3177
3178 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3179 must be replaced by calles to MWriteAsciiFile::AddColumn and
3180 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3181 changed.
3182
3183 - Implemented generalized event-matrices (one row per event)
3184 (MHMatrix)
3185
3186 - implemented the one dimensional composite probabilities
3187 (MHCompProb, MCompProbCalc, comprob.C)
3188
3189 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3190 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3191
3192 - Added a camera display displaying the pixel numbers to the
3193 event display gui.
3194
3195 - Added Monte Carlo Informations to event display gui
3196
3197 - Changed the camera display to display the pixel numbering
3198
3199 - Added three buttons to the camera display to change the palette
3200
3201 - Added the number of used and core pixels after image cleaning
3202 to MHillas
3203
3204 - Changed the algorithm used in MHillas according to TDAS 02-03
3205
3206 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3207
3208 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3209
3210 - Added fCosDeltaAlpha to MHillasSrc
3211
3212 - The numbers of photons used to calculate fConc and fConc1 in
3213 MHillasExt are now scaled with the pixel size, so that one get
3214 a four times smaller value for the bigger pixels in the outer ring.
3215
3216 - added new task to smooth the camera contents (MCameraSmooth)
3217
3218 - added possibility to use interpolated pixel values for blind pixels
3219 instead of removing it completely from the analysis
3220
3221 - Implemented the possibility to save the whole eventloop with
3222 its setup to a file. This information can be read and from
3223 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3224 and MEvtLoop::MakeMacro. If you find something not working, please
3225 report - this stuff is still in a beta phase.
3226
3227 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3228 file having crab starfield, but also for all following files - fixed
3229
3230 - MTaskList::PrintStatistics can now be instructud to print also the
3231 title, too: use PrintStatistics(0, kTRUE)
3232
3233 - Changed the image cleaning so that pixels with to many 'used'
3234 neighbors are left used (to get rid of 'holes' in events)
3235
3236 - Introduced more output to the camera displays
3237
3238 - Added an array of histograms (eg one hist per run), MHArray
3239
3240 - Added a _preliminary_ version of the reader for CT1 PreProc files
3241 (MCT1ReadPreProc)
3242
3243 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3244 (thanks to Raquel)
3245
3246 - added the first energy estimator (MEnergyEstParam, estimate.C,
3247 estfit.C) using a parametrization
3248
3249 - Added some new Monte Carlo paremeter containers used to store
3250 setup information from the MC chain (MMcConfigRunHeader,
3251 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3252
3253
3254
3255 *** Version 0.7 (2002/04/30)
3256
3257 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3258 the pedestal mean value was saved incorrectly. For files from
3259 this versions we substract 0.5 from the pedestal mean.
3260 WARNING: This may effect your results, so don't wonder...
3261
3262 - First implementation of an algorithm using only triggered events
3263 for the collection area calculation
3264
3265 - Ascii Output can now also be used for parameter containers which
3266 doesn't overload MParCointainer::AsciiWrite
3267
3268 - The Ascii Output is now also capable of writing single data members
3269 of one container
3270
3271 - You are now able to change the order of the values written to the
3272 ascii file
3273
3274 - You can now specify a conversion factor for each data member written
3275 to an ascii file. This may be usefull to change the units of the
3276 data member (eg. degrees instead of millimeters in case of the
3277 hillas parameters)
3278
3279 - Replaced old MHillas by a new structure which allows you to extend
3280 the parameters stored in MHillas very easily:
3281 see MHillas and MHillasExt
3282
3283 - Added classes to handle source dependancy of image parameters:
3284 see MHillasSrc
3285
3286 - Added container (MBinning) to have a standard input for the binning
3287 in different histograms (eg. the Energy bins should be the same in
3288 all histograms)
3289
3290 - Changed Hillas histograms from mm to deg
3291
3292 - Added the flexible binning to the hillas histograms
3293
3294 - Added a filter for the alpha parameter (MFAlpha)
3295
3296 - It is now possible to write single data members of a class object to
3297 an output stream instead of the whole container only
3298
3299 - Added a generalized filter for a data member:
3300 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3301
3302 - Added a generalized Filter parser for more difficult filter rules
3303 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3304
3305 - Added new Monte Carlo histograms:
3306 MHMcEnergyImpact and MHMcEfficiency
3307
3308 - Added many new histograms needed for the flux calculation.
3309
3310 - Added a generalized histograms which can fill and show up to three
3311 data members in either a one-, two- or three-dimensional histogram, eg:
3312 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3313
3314 - Added:
3315 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3316 * calculation of <Theta> as a function of time (MHThetabarTime)
3317 they are needed in the flux calculation in
3318 order to select for a given bin in Theta (or time) the appropriate
3319 effective collection area, which is assumed to be given as a function
3320 of Theta and the true energy
3321
3322 - Added calculation of the migration matrix in the energy
3323 (MHMcEnergyMigration):
3324 the migration matrix describes the migration from the true (E_true)
3325 to the estimated energy (E_est); it is needed to determine the
3326 distribution of E_true from the measured distribution of E_est
3327 by unfolding
3328
3329 - changed the color palette in the camera display to DeapSea.
3330
3331
3332
3333 *** Version 0.6 (2002/01/15)
3334
3335 - Introduce the option of disable pixels (MBlindPixels and
3336 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3337 able to deal with Star Field NSB.
3338
3339 - Fixed a bug in the pedestals substraction
3340
3341 - Introduced verbosity levels
3342
3343 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3344
3345 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3346 work correctly (thanks to Abelardo)
3347
3348 - Introduced correct treatment of the diffuse Night Sky Background
3349 and NSB (MMcPedestalNSB)
3350
3351 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3352
3353 - Introduced MMcRunHeaders which contains monte carlo run informations
3354
3355 - Added a 'Print'-Task (MPrint) which calls the Print function
3356 of a parameter container for each event
3357
3358 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3359
3360 - changes to be more efficient with root 3.02/06
3361
3362 - root 3.02/06 fixes:
3363 + the memory leak when reading MRawEvtData
3364 + loosing more time than necessary to update the progress bar
3365
3366 - MWriteAsciiFile is now capable of writing more than one container
3367 in a line. For example: To be able to write Monte Carlo and
3368 Hillas values (energy and alpha) in one line.
3369
3370
3371
3372 *** Version 0.5 (2001/11/06)
3373
3374 - Added new GUI functionality (Analysis)
3375
3376 - Added a camera display to be able to display events in the camera
3377 together with the calculated hillas ellipse
3378
3379 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3380 object at any state of the analysis, so that the output are several
3381 states
3382
3383 - Fixed a bug in the collection area error calculation
3384 (Thanks to Ciro and Abelardo)
3385
3386 - Fixed a bug which causes merpp to crash in some environments
3387
3388 - Implemented auto enabling scheme for Branches to speed up reading
3389 a lot (see MReadTree and MTask)
3390
3391 - Fixed a bug in the Histogram classes which caused histograms to
3392 be written to a file by MWriteRootFile without request
3393
3394 - changed the object I/O from the old stylish root I/O to the new
3395 'auto evolution scheme' This was done only for classes which are not
3396 yet used in Monte Carlo files, so that these files are still readable.
3397
3398 - Added support for a progress bar in MEvtLoop and MReadTree
3399 (see the Analysis Window in Mars for an example)
3400
3401 - Fixed a bug in the package creation which disturbed the conversion
3402 between a mars version unpacked from a tar file and the repository.
3403
3404 - Changed the code to writer merpped (converted into root format)
3405 raw files, to get faster (around 10%)
3406
3407
3408
3409 *** Version 0.4 (2001/09/20)
3410
3411 - This release is made to compile on a root version >= 3.00
3412
3413 - Fixed a bug which causes MReadTree to read the first file only
3414
3415 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3416
3417 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3418
3419 - Added a task to write several container to a root file (MWriteRootFile)
3420
3421 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3422
3423 - Added calculation of the collection area (MMcCollectionAreaCalc)
3424
3425 - fixed some bugs in the Hillas calculation
3426
3427 - added filters to be able to control the task execution dependent on
3428 a parameter (for example: the number of level 1 triggers in a MC-file)
3429
3430
3431
3432 *** Version 0.3 (2001/04/23)
3433
3434 - Many demo macros added
3435
3436 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3437
3438 - Hillas Calculation added
3439
3440 - Standard image cleaning available
3441
3442 - MReadTree is now able to handle more than one file
3443 (Remark: of the same structure)
3444
3445 - Now we are able to display events in a first version of the
3446 Camera event display. To do this we must run the macro
3447 "macros/readCT1.C" to read data from CT1.
3448
3449
3450
3451 *** Version 0.2 (2001/01/24)
3452
3453 - First Implementation of a Gui to read the raw data. Start the
3454 gui with the command mars.
3455
3456
3457
3458 *** Version 0.1 (2000/12/20)
3459
3460 - First official release 0.1
3461
3462 - Changes:
3463
3464 + changed calling style of MRawPixelIterator from do...while to
3465 while-loop
Note: See TracBrowser for help on using the repository browser.