Ignore:
Timestamp:
01/24/04 14:28:56 (21 years ago)
Author:
moralejo
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/Changelog

    r2906 r2907  
    44
    55                                                 -*-*- END OF LINE -*-*-
     6
     7 2004/01/24: Abelardo Moralejo
     8
     9   * mcalib/MCalibrate.cc
     10     - Added check that value of signal from MExtractedSignalPix is not
     11       the default (error) value. In such a case, the signal in
     12       MCerPhotEvt is now set to 0. Before, all pixels got very high
     13       values in MCerPhotEvt in case the MRawEvtData object for the
     14       event was missing in the file. This happened in MC files, in
     15       which in some circumstances an event is written without the
     16       pixel information (for instance, when running stereo simulations
     17       the pixel data is missing for non-triggered telescopes, but the
     18       event headers are present).
    619